HomeMy WebLinkAbout810 Catalina Dr 17-350; WINDOWSCITY OF SANFORD
BUILDING & FIRE PREVENTION
PERM IT APPLICATION
lication No:
r/ __ 3.n
oa
mmented Construction Value: $
Job Address: ale) co+a I 1 11Gi b Y'. Historic District: Yes No
Parcel ID: Residential Commercial
Type of Work: New Addition Alteration Repair VT Demo Change of Use Move
Description of Work: r.-e imcdeA '*r4"C A d a1 -raz el
SZe- ay -
Plan Review Contact Person: th Sa r OL Title:
Phone: 3(0S l Fax: Email: SO_r o.
Property Owner Information
Name 4164_ Sid
Street:.331 1-RALz cA Cie.
City, State Zip: _4s l'- 3 cn S
Phone: 4 _ -" (P' 8q C1 3
Resident of property? :
Contractor Information
Name Z_)G`n( 6 'G1:zt-CS=e-
Street: 9(.nl 0_!JIA('P.'
City, State Zip: .n t.2, Qi, `2
Phone: 1401 ao1P 0105 U
Fax:
State License No.: 1 i 3 _
Architect/Engineer Information
Name: Phone:
Street: Fax:
City, St, Zip: E-mail:
Bonding Company:
Address:
Mortgage Lender:
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit most be secured for electrical work, plumbing, signs, wells, pools, 0furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building CodeRevised: June 30, 2015 Permit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in complian R applicable laws regulating construction and zoning.
Signature o /Ag bete
Print_Qmx r/Agent's Natye..
Signawri oPNotary-State of Florida Date
SARA FARESE
NOTARY PUBUC
STA -` OF FLORIDA
Cotanot VF00160
Owner/Agent is ei6i>W Me or
Produced ID Type of ID
4-44 mia, Z G bI`1
tgneture of Confmc r/Ag bate
Print Con or/Agent's Name
Signature of Notary -State of Florida Date
THERESA S. CouCHf .X-M;
Commission S GG 041772
Expltus October25,
14'3• t%Mt1 TWUTmyFs*b
ontrac or gem ly ICno o Me or
Produced ID Type o
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof
Construction Type: Occupancy Use:
Total Sq Ft of Bldg: Min. Occupancy Load:
Flood Zone:
of Stories:
New Construction: Electric - # of Amps Plumbing - # of Fixtures
Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No
JACA^
APPROVALS: ZONING:2 q-1'/
se+
UTILITIES: WASTE WATER:
ENGINEERING:
COMMENTS:
FIRE: BUILDING: • l
Revised: June 30, 2015 Permit Application
I, Dantes Benitez Owner of #1 Stop Construction, give permission to
Transparacon Inc to resolve any permitting issues/redtags associated
with 810 Catalina Dr. Sanford FL 32771. Six windows were bought from
Lowes in the amount of $819.76. The windows were replaced, size for
size, for the above referenced address.
Dantes Benitez
transparacon inc transparacon inc
Februaray 6, 2017
CONTRACT TO PERMIT WINDOWS
RE: 810 Catalina Drive. Sanford, FL 32771
This is a contract between #1 One Stop Contracting Corp (Owner) and
Transparacon Inc (Contractor) to oversee and install windows at the above
referenced property. Owner will supply and install the windows. Contractor
assumes no responsibility or warranty for the resulting work. This contract is
for permitting services only.
U
Transparacon, Inc.
12
Dantes MniAz 46te:
President
1 One Stop Contracting Corp.
N RECORD COPY
I`
i
v.... . . .,/`•:y r 4.1.../.t f. / rC I,h . •1 .,;1ai .- Jy,`ltirl
i
i
REVIEWED FOR CODE COMPLIANCE 41
PLANS EXAMINER '
DATE
SANFO__ RD BUILDING DIVISION
A PERMIT ISSUED SHALL BE CONSTRUED TO BE A
LICENSE TO PROCEED WITH THE WORK AND NOT AS
AUTHORITY TO VIOLATE; CANCEL. ALTER OR SET
ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL
CODES. NOR SHALL ISSUANCE OF A PERMIT PREVENT
THE BUILDING OFFICIAL FROM THEREAFTER
REOUIRING A CORRECTION OF ERRORS IN PLANS.
CONSTRUCTION OR VIOLATIONS OF THIS CODE
L•
tl
I LIt
V\lD
W60M
64AR:[\4 -
17-350
0
Vafidator / Operations Administrator)
JELD•WEN Windows & Doors
P.O. Box 1329
Klamath Falls, OR 97601
Attn: Jason Kantols
AAMA
CERTIFICATION PROGRAM
AUTHORIZATION FOR PRODUCT CERTIFICATION
This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an
AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory.
SPECIFICATION
RECORD OF PRODUCT TESTED
AAMAIWDMA/CSA 101/I.S.2/A440-08
R-PG504219x1956 (48x77).H
COMPANY AND CODE CPO NO.
SERIES MODEL & PRODUCT
MAXIMUM SIZE TESTEDDESCRIPTION
BUILDERS VINYL TILT SH
FRAME SASHJELD•WEN Windows & Doors
9785
PVC)(O/X)(OG)(INS GL)
1219 mm x 1956 mm 1168 mm x 973 mmCode: JW MODIF)(REINF)(TILT)
4 O„ x 8, S) 310„ x 3, 2)
ASTM)
This Certification will expire October 4, 2021 (extended from October 4, 2016 per AAMA 103.15) and requires validation until
then by continued listing in the current AAMA Certified Products Directory.
Product Tested and Reported by: National Certified Testing Laboratories
Report No.: SJW2012.202
Date of Report: October 29, 2012
JGS/JTS
ACP-04 (Rev.6/16)
Evaluated for Certification: June 21, 2016
4te, A -at
d Laboratories, Inc.
Authorized for Certification: June 22, 2016
Amen n Architectural Manufacturers Association
e MAX.
12' O.C. MAX. FROM
THRu nN CORNERS
MIDSPAN
WINDOW WIDTH [48- MMI—LA
12' O.C.
MAX. TNRu
TNRu nN
TYPICAL ELEVATION WITH FASTENER SPACING
InsUbdon Notes:
1. Seal 8angelframe to substrate.
2. Use #8 PH or greater fastener though the nal fin with sufficient length to penetrate a minimum of 1 1/r
into the wood framing. For 2X wood frame substrate (rMn. S.G. = 0.42).
3. Host sbvcWre (wood buck, masonry, steel) to be designed and anchored to properly transfer all bads
to the structure. The host structure is the responsibility of the architect or engineer of record for the
project of installation.
Digitally signed by Hermes F. Norero, P.E.
This sdnedule addresses only the fasteners required to anchor the Reason: I am approlvi.ng this document
window to achieve the rated design pressure up to the size limitations
Date: 2ota.09 i1 9314'"W'
Wed. It is rat intended as a guide to the installation process and does i
not address the sealing consideration that may arise in different wall •••••••• `
conditions. For the complete installation procedure. see the instructions : ° •' :O
padw* with the window or go to
www en.comlresoureesrmstalladon.
DISCLAIMER: -
O : T T
This drawing and its contents are confidential and are not to be
p '•.
P
reproduced or copied in whole or in part or used or disclosed to others 1
to.
NO. %
except as authorized by JELO-WEN Inc. aUN-
NAIL FIN INSTALLATION
ur VIM EMIMMEW t--
2 2X WOOD FRAME
MAJ, DISTANC7=
MIN. DISTANCE FOR EWE: 3/4•
FOR EDGE.. 3/r
2X WOOD
yr MAx 3 FRAME
SN[M SPACE
1/4• MAX
SHIM SPACE
FRAME SECTION (TV)
I I
1 1/r MIN.
VERTICAL SECTION EMBEDMENT
Ism or.......a..r....,..w.
JAMB SECTION (TYP)
HORIZONTAL SECTION
V4• MAX NM CPA W e"M MA%Fby. "bW 40.9
M SPACE
W N DWANCE
FOR EVE.3N•
BUILDERS VINYL SINGLE HUNG
2x WOW FRAME Max Frame I DP RATIW IMPACT
yrMIX EMBEOMEW 48 x 77 *50/-50 NO General
Notes: 1.
The product shown herein is designed, tested and manufactured to comply with the wind load criteria of
the adopted International Building Code(IBC), the International Residential Code(IRC), the Amida Building
Code(FBC) and the industry requirement for the stated conditions. 2.
All Glazing shall conform to ASTM E1300. 3.
At minimum, glazing shall be single strength annealed insulating glass. 4.
Use structural or Composite shims where required. 5.
Maximum saes are buck sizes and do not include An or flange. 07/
17/2014 1 3737 Lakeport Blvd MAWN
9r: SCIuf. Klamath Falls, OR. 97601 D.
VezO I NTS PMLDNM Phone: (541) 882-3451 Builders
Vinyl rift Single Hung m
r00 I9*" 1oF4
e MAX. MAl Dt5TANM
FORE06E:air
CCOORNNERS 3
III O.C. EMBEtwfM
MAX. TMRU
THRU JAMB
t ur MAX
5{QM VAa
FRAME SECTION (TYP)
VERTICAL SECTION
s
y
Z
1 ur MAX
5N" WAM
Z urMM
EMBEDMENT
3
TYPICAL ELEVATION WITH FASTENER SPACING MtN.otsTANCE
FOR EDGE: We
YI06PAN
Y106PAN
wurlww wltmr a MAx.
Installation Notes:
1. Seal flangettrame to substrate.
2. Use #8 PH or greater fastener though the frame with sufficient length to penetrate a minimum of 1112'
into the wood framing. For 2X wood frame substrate (min. S.G. = 0.42).
3. Host structure (wood buds, masonry, steel) to be designed and andgred to property transfer all loads
to the strudure. The host structure is the responsibility of the architect or engineer of record for the
project of installation.
This schedule addresses only the fasteners required to anchor the %1 t t t 11
window to achieve Me rated design pressure up to the sae finribbons %1 —
i
noted. It is not intended as a guide to the installation Mom and does %%
not address the sealing consideration that may arise in different wall
condift ns. For the complete installation procedure, see the irnstructions
packaged with tine window or go to -
www.jell-wen.comlresouroesfnnstalladon. _ *
DISCLAIMER:
This drawing and its contents are Confidential and are not to be %440
reproduced or copied in whole or in part or used or disclosed to others _0l
except as authorized by JELD-WEN Inc. eos is bra,.,, ass
THROUGH FRAME
INSTALLATION
EMBEDMENT
1/4• MAX
3 s+IM SPACE
MIN. CISTANCE Z
FOR EDGE: 3/4•
1
JAMB SECTION (TYP)
HORIZONTAL SECTION
BUILDERS VINYL SINGLE HUNG
Max Frame DP RATING IMPACT
as x n •50i-50 No
General Notes:
1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria
of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida
Building Code(FBC) and the industry requirement for the stated conditions.
2. AN glazing shall Confoml to ASTM E1300.
3. At minimum, glazing shall be single strength annealed insulating glass.
4. Use structural or composite shims where required.
5. Maximum sizes are buds saes and do not include On or flange.
JJ0:Ld39r1VV7M707/17/2014 3737 Lakeport Blvd
oaAwn ,: : IUamath Fags, OR. 97601
D. VezO WTS Phone: (541) 882-3451
BY: 1 Builders vinyl Tilt Single Hung
4' MAX. I MASONRY INSTALLATIONFROMMAM1MOtSrANX
r--r CORNERS
J
a e ..
MIDSPAN III O.C. EwEOMEN
MAX. TNRU
TNRU JAMB r w- MOJ.
EMBEDMENT
yr Auz
N 9ACE 3 1/4' MAX
MM DISTANCE V SHIM SPACE
FRAME SECTION TYP FOR EDGE: 2 yr Z
n
V RTICAL S CTION
a:
V
MIDSPAN MASONRY
BLOCK
g 1
JAMB SECTION (TYP)
HORIZONTAL SECTION
t vrrAx
SIQM PACE
o ' E BUILDERS VINYL SINGLE HUNG
WINDOW WIM (40MAX.)— II TYPICALELEVATIONWITHFASTENERSDACTNt± fl MD4DISTANCE + Max
Frame DP RATING IMPACT 48
x 77 50/-50 NO Installation
Notes: 1.
Seal Nangelframe to substrate. 2.
Use 3116' Tapoon or equivalent fasteners through frame with sufficient length to penetrate a minimum of
1 114* Into concrete or masonry at each bcation with a 2 UT min from edge distance. For concrete min. =
3000psi) or masonry (CMU shall conform to ASTM C90). 3.
Host structure (wood buck, masonry, steep to be designed and anchored to property transfer all bads to
the structure. The host structure is the responsibility of the architect or engineer of record for the project
of installation. This
schedule addresses only the fastener; required to anchor the window
to achieve the rated design pressure up to the size limitations noted.
It is not intended as a guide to the installation process and does not
address the sealing consideration that may arise in different wag • conditions.
For the complete installation procedure, see the instructions packaged
with the window or go to www
jekf-wen.comlresoumesrmstabbw DISCLAIMER:
This
drawing and its contents are Confidential and are rot to be reproduced
or copied in whole or in part or used or disclosed to others i 1 except
as authorized by JELD-WEN Inc. See 1 11111111//
JJ Q
c A • FOR
toot: I General
Notes - I.
The product shown herein is designed, tested and manufactured to comply with the wind bad criteria of
the adopted Intemational Building Code(IBC), the International Residential Code(IRC), the Florida Building
Code(FBC) and the industry requirement for the stated conditions. 2.
All glazing shelf conform to ASTM E1300. 3.
At minimum, glazing shag be single strength annealed insulating glass. 4.
Use structural or composite shims where required. 5.
Maximum sizes are buck sizes and do not include in or flange. 07/
17/2014 3737 Lakeport Blvd N
Klamath Falls, OR. 97601 oRAYMWiSC#M D.
VezO NTS Phone: (541) 882-3451 I.
E EKaR. TITLE* Lr Builders
Vinyl Tit Single Hung AMWOVEDBT: IfQj
PBT0
kSJW2012-
202-
F P Arrr N nE ANo wuna+ m REV: 00 SHEET
3a•
r MAX. Mu+ otsrArdcE
FROM OR E06E: uY
f ---r CORNERS of dwu "reads
j 3 post ftaos
1 t • O.C.
MAX. TNRu
s ga19C Tin
St.d skid
THRU JAMS
1 ur MAX
SQM SPACE
FRAME SECTION (TYP)
VERTICAL SECTION
x
g
t VI' MAR
StttM SPACE
is 9aye an
Stw Skid
3 Mak.,ro.mnen
Weeft
MAX.) peostflan. mw
TYPICAL ELEVATION WITH FASTENER SPACING FREVAAUr
YIDSPAN
Y106PAN
WINDOW w10T11 18• MAX.
Installation Notes:
1. Seal flangeftme to substrate.
2. For anchoring into metal framing, use q8 TEK Self Tapping screws with sufficient length to achieve a
minimum embedment of three threads past the frame thickness. Locate anchors as shown in
elevations and installation details. Steel substrate min.18ga., ly a 33 ksi.
3. Host stricture (wood buck, masonry, steel) to be designed and anchored to properly transfer all bads
to the structure. The host structure is the mspons iiity of the architect or engineer of record for the
project of installation.
This schedule addresses only the fasteners required to anchor the 111 l l t 111windowtoachievetherateddesignpressureuptothesaelimitations %o ,
noted. It is not intended as a guide to Bre installation process and does %%
not address the sealing consideration that may arise in different wall Q' • •••••
i:on Wons. For the Complete installation procedure, see the instructions
packaged with the window or gob 7
www.jeld wen.comlresourcesrmsWWdon.
DISCLAIMER: : &
7 r'Df?-- This
T T
drawing and its Contents are confidential and are not to be %
reproduced or copied in whole or in part or used a disclosed to others teexceptasauthorizedbyJELD-WEN Inc, ate Mo r
STEEL INSTALLATION
le gouge min
Stec Stud
1/4• MAX
Mw. olsrANc1: 3 SHIM SPACE5°"
FOR E06E:1/2•
Min. smbedmuA
of three tM•eodt ' 2
post from
JAMB SECTION (TYP)
HORIZONTAL, SECTION
6UILDERS VINYL SINGLE HUNG
Max Frame DP RATING IMPACT
48 x 77 *50/-50 NO
General Notes:
1. The product shown herein is designed, tested and manufactured to comply with Uhe wind load criteria
of the adopted international Building Code(IBC), the International Residential Code(IRC), the Florida
Building Code(FBC) and the industry requirement for the stated conditions.
2. Ali glazing shall conform to ASTM E1300.
3. At minimum, glazing shag be single strength annealed insulating glass.
4. Use structural or composite shuns where required.
5. Maximum saes are bulk sizes and do not induce fin or flange.
i — 07/17/2014 3737 Lakeport BMd
0 down er: wux; N Klamath Fags, OR. 97601
D. Vezo WTS Phone: (S41) 882.3451
AIBOfEO er• urns
J. Kantola
Rudders Vinyl Tilt Single Hung
use
Validator / Operations Administrator)
JELD-WEN Windows & Doors
P.O. Box 1329
Klamath Falls, OR 97601
Attn: Jason Kantols
AAMA
CERTIFICATION PROGRAM
AUTHORIZATION FOR PRODUCT CERTIFICATION
This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an
AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory.
SPECIFICATION
RECORD OF PRODUCT TESTED
AAMAIWDMAICSA 101/1.S.2/A440-08
R-PG35=914x2134 (36x84)-H
COMPANY AND CODE CPD NO.
SERIES MODEL & PRODUCT
MAXIMUM SIZE TESTEDDESCRIPTION
BUILDERS VINYL TILT SH
FRAME SASHJELD•WEN Windows & Doors
785
PVC)(O/X)(OG)(INS GL)
914 mm x 2134 mm 865 mm x 1065 mmCode: JW MODIF)(REINF)(TILT)
31O„ x 7, 0) 210 x 3, 6) ASTM) This
Certification will expire December 20, 2019 (extended from December 20, 2016 per AAMA 10345) and requires validation until
then by continued listing in the current AAMA Certified Products Directory. Product
Tested and Reported by. National Certified Testing Laboratories Report
No.: SJW2010.179 Date
of Report: January 17, 2011 JGS/
JTS ACP44 (
Rev.6/16) Evaluated
for Certification: September 6, 2016 A
IX 141
d Laboratories, Inc. Authorized
for Certification: September 6, 2016 T
Ameri
Architectural Manufacturers Association
h
TY 74LL
no
HEVATCCR! WCTH fASIEFER 5 AC7N6
Notes:
t. Seal flangefbame to substrate.
2. Use ff8 PH or greater fastener though the nab fin with sufficient length to penetrate a minimum of 1' into
the wood Naming. For 2X wood frame substrate (min. S.G. = 0.42).
3. Host structure (wood buds, masonry, steel) to be designed and anchored to properly trarWer all bads
to the structure. The host structure is the responsibility of the architect or engineer of record for the
project of installation.
This schedule addresses only the fasteners required to anchor the
window to achieve the rated design pressure up to the size limitations
noted. It is not intended as a guide to the installation process and does
not address he sealing consideration that may arise in different wall
conditions. For the complete installation procedure, see the instructions
packaged with the window or go to
www.jeld-wen.00mlresoun:esfmstallaUak.
MUI EAVEWW
WOOD FRAME
AUX DISTANCE
FOR E06E. W4*
Vr MAX
SHIM SPACE
FRAME SECTION
VERTICAL SECTION
SHIM SPACE
MD1 OtstAIYE
fORE06E Lr
0t w000 FRAME
Installation
NAIL FIN INSTALLATION
MIN, DISTANCE
FOR Eb6E: 3Ar
2X W000
FRAME
3
2
r/1• MAX
SHIM SPACE
r Aum
EMBEDMENT
1
JAMB SECTION (TYP)
HORIZONTAL SECTION
NOIE e.a bww ir A MAAo....
BUILDERS VINYL SINGLE HUNG
Max Frame DP RATING IMPACT
36 x 84 +/-35 NO
General Notes:
1. The product shown herein is designed, tested and manufactured to comply with the wind bad criteria
of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida
Building Code(FBC) and the industry requirement for the stated conditions.
2. All glazing shop conform to ASTM E1300.
3. At minimum, glazing shay be single strength annealed insulating glass.
4. Use structural or composite shims where required.
5. Installation methods can be interchanged within the same opening.
6. An impact protective system is required where wind bourne debris protection is mandated by local
building code.
7. Maximum sizes are buds sizes and do not include tin or flange.
MtOieCr mum DATE: 3250 Lakeport BlvdOS/13/13
WW" BY: scut JKDNM Klamath Falls, OR. 97601
D. Ve20 NT5 Phone: (sal) 882.3451
DECLAIMER:
AFFROM OY= Builders Vinyl Tilt Single Hung
r .s drawing and its contents are confidential and are not to be
Nail Fin Installation (36" x 84")
reproduced or copied in whole or in part or used or disclosed to others UUVO
cypept as authorized by JELD-WEN Inc. Mpg y-r®• rSJW2010-179-f smtrsH 00 I I
REQUIRED INSPECTION SEQUENCE
BP# 11- 35o Address: R l o CW-ku j A 1-k—
BUILDING PERMIT
Min Max Inspection Description
Footer / Setback
Stemwall
Foundation / Form Board Survey
Slab / Mono Slab Pre our
Lintel / Tie Beam / Fill / Down Cell
Sheathing — Walls
Sheathing — Roof
Roof Dry In
Frame
Insulation Rough In
Firewall Screw Pattern
Drywall / Sheetrock
Lath Inspection
Final Solar
Final Firewall
Final Roof
Final Stucco / Siding
Insulation Final
Final Utility Building
Final Door
Final Window
Final Screen Room
Final Pool Screen Enclosure
Final Single Family Residence
Final Building Other
ELECTRICAL PERMIT
Min Max Inspection Description
Electric Underground
Footer / Slab Steel Bond
Electric Rough
T.U.G.
Pre -Power Final
Electric Final
Min Max Inspection Description
Plumbing Underground
Plumbing Sewer
Plumbing Tub Set
Plumbing Final
MECHANICAL PERMIT
Min Max Inspection Description
Mechanical Rough
Mechanical Final
Min Max Inspection Description
Gas Underground
Gas Rough
Gas Final
REVISED: June 2014