Loading...
HomeMy WebLinkAbout343 Monroe Rd 17-230 PLUMBINGCITY OF SANFORD E MAY 2 t 27OVI BUILDING & FIRE PREVENTION PERMIT APPLICATION 50 r o Oaf No: Documented Construction Value: S- 2:5 66a °— Job Address: 34 3 M -M 23historic District: Yes No Parcel ID: 1(,— 1. 3 a' S 11 rc- C>OO 0 1 Residential Commercials. Type of Work: NewEl Addition Alterration Repair Demo Change of Use Move Description of Work: _TA;-f_- 1 Ine. w `1 e y - 4i C o.. \ e1 ec+- c ' r P otjvvn n - Plan Review Contact Person: Kelli Sessions Title: Operations AA Phone: 407-585-3252 Fax: 407-585-3277 Email: kas0wiainton net Property Owner Information Name U -L Pholid: Street: J' 70( DC) T- COMo(Z.-T S o Resident of property?: City, State ZipO u I CCV3 Contractor Information t' n Phone: 407-585-32.52Name ginton Fire S istem -Charles Patrick - Street: 699 Aero Lane Fax: 407-585-3277 City, State Zip: Sanford Florida 32771 State License No.: FPC15-000105 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: Bonding Company: Address: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electricnl work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51^ Edition (2014) Florida Building Code Revised: June 30, 2015Permit Application ici1 A A Fee M NO-TICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the.property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 1,V ., Q-- C23 L, Signature of Owner/Agent Date Signature of Contractor/Agent Date Print Omer/Agent's Name Signature of Notary -State or Florida Date Charles Patrick Print Co tractor/Agent's Name V KELLI SESSIONS Notary Public - State of Florida Commission # FF 215202 My Comm. Expires Mar 90, 2011 Owner/Agent is Personally Known to Me or Contractor/Agent is X_ Produced ID Type of ID Produced ID Type of 1D BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE S k l BUILDING: COMMENTS: Revised: lune 30.2015 Permit Application McKee ?'a frmrot Road SSamford,o/rtl, R. 32771 CONSTRVCTIOM CO. (4117) 323-1150 F1\ 1407023-10WW GENERAL CONTRACTORS SUBCONTRACT AGREEMENT CONTRACTOR: McKee Construction Co. SUBCONTRACTOR: Wiginion Fire Systems PROJECT: GANESH NORTH LLC ADDRESS: 343 MONROE ROAD SANFORD. FL 32771 CONTRACT NO: 2016-05-42 JOB NO: 2016.05 GANESH NORTH LLC DATE. November 14, 2016 CODE: 15500•--5415,000.00 CONTRACT PRICE (INCLUDES ALL TAXES) NOT TO EXCEED $415.000.00 WITH TEN 110%) RETAINAGE, PAYABLE AS FOLLOWS: MONTHLY PROGRESS PAYMENTS SHALL BE BILLED ON OR BEFORE 2011, OF 140111H FOR WORK THROUGH THE END OF MONTH. PAYMENT BY THE OWNER TO MCKEE CONSTRUCTION CO. SHALL BE AN ABSOLU TE CONDITION PRECEDENT TO MCKEE CONSTRUCTION CO. OBLIGATION TO MAKE INTERIM PROGRESS PAYMENT TO SUBCONTRACTOR, AND NO FUNDS SHALL BE OWED BY MCKEE CONSTRUCTION CO. TO SUBCONTRACTOR UNLESS MCKEE CONSTRUCTION CO. IS PAID BY OWNER. ONLY MCKEE CONS TRUC I ION CO. SUPPLIED PAY APPLICATION WILL BE ACCEPTED FOR ALL PROGRESS AND RETAINAGE PAYMENTS, ALL LIEN LAWS ARE APPLICABLE. FINAL PAYMENT BY OWNER rO MCKEE CONSTRUCTION CO. IS A CONDITION PRECEDENT TO MCKEE CONSTRUCTION CO. OBLIGATION TO MAKE FILIAL PAYMENT TO SUBCONTRACTOR. THE RELEASE OF MCKEE CONSTRUCTION CO. RETAINAGE BY THE OWNER IS A CONDITION PRECEDENT TO TO RELEASE OF SUBCONTRACTOR'S RETAINAGE BY MCKEE CONSTRUCTION CO. SUBCONTRACTORS PROPOSAL DOES NOT SUPERSEDE ANY AND ALL ITEMS REQUIRED IN PLANS AND SPECIFICATIONS FOR WORK TO BE PERFORMED ON PROJECT, UNLESS SUBCONTRACTOR'S PROPOSAL CHANGES HAVE BEEN AGREED UPON BY BOTH PARTIES AT PRICING STAGE OF PROJECT.SC1OPEOF WORK WRITTEN SCHEDULE MUST BE PROVIDED PRIOR TO it' APPLICATION FOR PAYMENT BEING PROCESSEDI 1.Subcontractor agrees to participate In weekly Jobsbe and Salery meeting's on site. Meeting will discuss project and issues that may arise during construction of project. Subcontractor is responsible for updating McKee Construction Co. in regards to schedule, material availability and general progress of subcontractor SCAM. - of work on a vreekly basis. 2.Subcontractor agrees to perform all labor In a workmanlike manner. to prosecute said work In accordance vnth Contractors schedule and to complete all vork in a prompt and professional manner. Subcontractor is rye ulred to clean up scop= of work fob debris on a doily basis. failure to maintain this policy will result In McKee Construction Co. issuing a vritten notice of deficency and will subseguenlly hire clean mD workers which vAll result In a hackcharme to the subcontmctor. 3. Subcontractor further agrees that he has in lull force and effect this date and will continue in force during the course of his work, Workmen's Compensation Insurance, as required by law, and Public Liability and Property Damage Insurance as is reasonably necessary to insure against the risk arising out of this contract A certificate of said Insurance Is to be received by the Contractor within three 131 days follovAng the execution of this contract. In no case will any work be commenced prior to recelpt of the Certificate by the Contractor. "Prior to the completion of work operations on this property, none of the above Insurance Is to be cancelled, changed, or allolved to lapse until 30 days prior written notice has been given to the Contractor." 4. In addition to standard manufacturers warrantles for any equipment installed by Subcontractor. Subcontractor guarantees all work against defects from the use of ferlor or defective materials, equipment or workmanship for one year from the dale at occupancy b X theaotmet (Certificate of Occupancy I Ce ificate of ompletlon)_ All repairs or changes required In connection with this Guarantee will be performed promptly at the Subcontractor's expense. 6. Subcontractor required to acknowledge McKee Conotruclion Co. safely policies manual on rile, and adhere to all such policies. McKee Construction Cu. requires Hard hats to be worn at all times on jobsile, failure to adhere to this policy +null result in the immediate expulsion o: violators from jobsile. The subcontractor agrees t: furnish McKee Construction Co. with Material Safety Data Sheets for all hazardous materials that will be used on this project by subcontractor or his sub. subcontractors. 7. The subcontractor is to comply with all current OSHA regulations. Sdfely to. the Subconu3ctor's employees is the responsibility of the Subcontractor. Subcontractor shall maintain a competent person on site during the course of the subcontractor's work. In the event that the Subcontractor is in viciadon on any OSHA safety regulations. all loses, damages• and expenses incurred including OSHA fines mcurrnd as a result of said violation shall be borne by and Charged against the Subcontractor. 8. Atckee Construction Co adhere's to a drug free work environment. All companies and their employees who perform work under this subcorlract agreement on McKee Construction Co. jobsites are subject to random drug testing as a requirement of this contract. If relusal or positive lasting takes place McKee Construclru.t Co. reserves the right to ban Irom performing work under this contract individual or inoivnduafs that violate this policy. 8. hlcKee Construction Co. requires the subcontractor to have on )obstle at all limes a qualified lorentan to maintain proper comimunlwtion vrnh McKee Consuucuon Co. project manager and or superintendent. Violation of this agreement will result in immediate termination of this subcontract after written notice has been delivered to subcontractor. It termination of contract occurs. subcontractor agrees to cover any cost overage's that may lake place in completing the scope of rrorlt. 9. As part of the acceptance of this Subcontract. Subcontractor wilt provide to McKee Construction Co. a list of all princl aI ss and key empIoy_ee't cellular -phone numbers. Monthly Pay request will not be paid until these numbers have boon supplied to McKee Construction Co. If at any time the Subcontractor fails to respond in atimely manner, McKee Construction Co. has the right to terminale said contract upon written notice of deficencies. 10. Subcontractor Is responsible for the maintenance of their scope of work items until Certificate of Occupancy I Certificate of Complotion is secured. 11. Subcontractor may after subcontract issuance request written permission for substitutions of items specified in project documents, a complete submittal wAll be required with any possible savings which will be reviewed for conformity by both the contractor and related design professionals. Contractor will issue a written lelte• of approval or denial as to the suhstihdon request being granted Accepted: Contractor McKee Construction Co. 790 MONROE ROAD Accepted- Subcontractor Wigrnion Fire Systems 699 Aero Lane Sanford, FL 32707 SANFORD, FL 32771 Pete Aziz (407) 585.3277 ce!I (407 453-9269 Authorized Signature: ,uthorized Corporate Signature l int Nome: ,) C - ate:_ _//* b Print ' Title: Date. IF 6—- riarfes M. -Patrick ____.-- I Vice President, Branch Manager M., t /-. ltwo1 FIRE Mill OSinQ Form S-600 PROPOSAL Page 1 of 10 Date: 11-2-16 1 WFS Proposal #: Customer: McKee Construction Co. Address: 790 Monroe Rd. Sanford FL. 32771 Contact: Joe Nicholas Phone: 407-323-1150 Fax: 407-323-9304 Cell: Project: Ganesh North Revised 11-2-16 Location: NEC Monroe Rd. & Narcissus Ave. Owner: Eng.: 1 Architectural Dynamics, Inc. Sheet #'s & Dates: 7-20-16 Addenda (list): EOR: Wiginton Fire Systems (WFS) proposes to fumish materials and labor as specified below at the prices stated below: SCOPE OF WORK INCLUDED: Begin work 1'-0" AFF in cub of five (5) buildings and install five (5) wet pipe automatic fire sprinklers systems in building I and one (1) system in buildings 2-5. Price does not comply with fire protection plans of specifications or metal building manufacturer's hanger requirements and is based on 8" steel purlins. Systems will be designed, fabricated and installed per NFPA 13. All materials including pipe will be per NFPA 13. All pipes will be supported Rom the sides of purlins. Trapeze hangers are not included. Price does not include in -rack sprinklers, hose stations (see alternate) or sprinklers inside or below exterior canopies. Per City Sanford, signs prohibiting storage must be posted at the loading dock where canopies will be concocted. Price does not comply with insurer's requirements and is subject to change after confirming the composition of any stored commodities and any requirements the owner's insurer may have pertaining to the design of the fire protection systems. All mains will be installed tight against the bottom of beams running north to south. High Volume low Speed (HVLS) fens should be wired to be shut down in the event of a fire/flow switch activation. Price is subject to change after review of the project schedule and discussing manpower expectations. All systems in building 1 will be limited to 40,000 square feet. Price for building 1 Includes a Ore pump, Mclarifications are as follows. u protection of class 3 commodities stored on double row pallet racks, nomencapsulated, with minimum 8'-O" aisles to a maximum of twenty feet. Price includes five (5) systems. Four (4) systems will be designed as ESFR systems designed to include 12 K16.8 sprinklers operating at 52 PSI and One system (vacant space -SW comer) utilizing standard storage sprinklers to protect a class 3 commodity also on double row racks to a maximum height of TWENTY (20) feet. Proposal includes a fug pump and the necessary underground for a free standing yard -type rim department connection. Jatno work: 313,652.00 Under un : Total (Building 1): S325,066.00 Buildings 2-5: Systems will be designed per NFPA 13 -light hazard. Depending on future tenants, light hazard may not be adequate and upgrades will be required (not included). Buildings will be protected as "shells" with upright sprinklers installed at the root Seller reserves the right to utilize extended coverage sprinklers. Building 2:$22.777.00 Building 3:$22,190.00 Building 4: 522,777.00 Building s: 522,190.00 Additional clarifications, exclusions are noted below and throughout proposal. NOTE: Attachments referenced by project name and WFS proposal 0 and dated shall be Incorporated completely as If written berein. Prouosed Schedule: TBD Wiginton Fire Systems 699 Aero Lane, Sanford, FL 32771 - Phone: (407) 585-3200- Fax: (407) 585-3277 TO: City of Sanford 300 North Park Avenue Sanford, FL 32771 Attn: Building Department Re: Letter of Authorization for Permit Ladies/Gentlemen: Please accept this letter as my authorizationfor 1k ss o s to represent me (Charles Patrick) in my absence, to eliver, sign for and pick-up approved drawings for our permits. Sincerely, WIGINT IR TEMS BY: Nginton Fire Systems Vice President, Branch Manager Charles Patrick License Number: FPC15-000105 State of: Florida County of: Seminole The foregoing instrument was acknowledged this -day of /, f , 2017, by Charles Patrick, who personally appeared before me and ackno edged that he, signed the instrument voluntarily for the purposes expressed in it. t5 Personally Known o Produced Identification JOANE L. SUAREZ awXavl J, t Nobry Poetic Stine of FloorldsI . LC ' • Canmlttlon I, FF 92558060 NOTA -AY PUBLIC, STATE OF ORIDA ;•, tinugh ° IationamN2tary2, ssn Additional Full Service Locations Jacksonville, FL (904) 262-6107 - Daytona Beach, FL (386) 257.4300 - Miami, FL (305) 625-0004 - Tampa. FL (8 13) 623-2333 yWigintonFireS stems 699 Aero Lane, Sanford, FL 32771 - Phone, (407) 585-3200 - Fax* (407) 585-3277 LETTER OF TRANSMITTAL TO: City of Sanford 300 North Park Avenue Sanford, FL 32771 We are sending you the following items: o Fire Sprinkler Permit Package Date: May 23, 2017 Job#: 2010771 Attn: Plan Review Re: Ganesh North — Bldg. 1 OH COPIES NO. DESCRIPTION 1 31159 Check for deposit on permit fee $25.00 3 Signed and Sealed Plans, Submittals, and Calcs 1 Permit Application 1 Certificate of Insurance 1 Certificate of Competency 1 Signed subcontract Agreement with Proposal Price Breakdown 1 Letter of Authorization Remarks: If you have any questions, please call me at (407) 585-3252, or email at kasa-wiginton.net. Cc: Contract File Signed Thank You, Kelli SessioAs Operations Administrative Assistant Wayne Ammons, Designer Additional Full Service Locations Jacksonville, FL (904) 262-6107 - Daytona Beach, FL (386) 2574300 - Miami. FL (305) 625.0004 - Tampa. FL (813) 623-2333 FIRE INSPECTIONS CITY OF SANFORD 407.562.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Page 2 Application Number . . . . . 17-00000230 Date 5/23/17 Application pin number . . . 713890 Revision number . . . . . . . 3 Special Notes and Comments No new plumbing fixtures per plans. no additional impact fees March 29, 2017 11:25:05 AM blaker. additional impact fees Add- water impact fee $4700.50 Add -sewer impact fee 10,587.50 Other Fees . . . . . . . . . 01-APPLCTN FEE -ELECTRIC 25.00 01-APPLCTN FEE -BUILDING 100.00 01-APPLCTN FEE -PLUMBING 25.00 01 -BLDG PLAN REVIEW 21243.00 01 -EARLY START AUTHORIZED 250.00 01 -FIRE SPRINKLER TESTING 150.00 01 -FIRE INSPECT -NEW CONST 8056.00 01 -FIRE IMPACT 8-2015 13297.67 01 -PLAN ALTERATIONS 50.00 01 -POLICE IMPACT 8-2015 16664.60 01 -SEM CNTY RD IMPACT FEE 59607.00 WD IMPACT:COMMERCIAL 8058.00 SD IMPACT:COMMERCIAL 18150.00 01 -BLDG DCA SURCHARGE 1082.12 01 -BLDG DBPR SURCHARGE 1082.09 Fee summary Charged Paid Credited Due Permit Fee Total 124.00 124.00 .00 00 Other Fee Total 147840.48 147815.48 .00 25.00 Grand Total 147964.48 147939.48 .00 25.00 CITY OF SANFORD r+t CUSTOMER RECEIPT mr* Oper: BLANDA Type: OC Drawer: 1 Date: 5/23/17 81 Receipt no: 129M Year Number Amount 343 NO1% RD 238 N} SANFORD, FL 32771 BP BUILDING PERMIT RECEIPTS 25.88 Tender detail CK CHE(X 31159 $25.88 Total tendered $25.88 Total payment $25.88 frans date: 5/23/17 Time: 18:8:44 FAILURE TO COMPLY WITH MECHANIC'S LEIN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS. NOTE: ALL FEES MUST BE PAID PRIOR TO C.O. BEING ISSUED. NOTE: PLEASE BE ADVISED ALL PERMITS MUST BE INSPECTED. DATE: '5/ v CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION PEck CE 17- 10 BUSINESS/PROJECT NAME: JJ ADDRESS: CONTACT NAME: FIRE PLAN REVIEW SERVICE FEES PHONE: 407.688.5052 FAX: 407.688.5051 PERMIT NUMBER: /7- Z-30 PHONE: PLAN REVIEW INFORMATION CONSTRUCTION [ ]C/O [ ] FIRE ALARM [I/FIRE SPRINKLER []HOOD [ ]PAINT BOOTH [)TANK DOES 20% REDUCTION IN FIRE IMPACT FEES APPLY: ( ) YES NO TOTAL FEES: Revision 6d I rll- City of Sanford Response to Comments Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Permit # 230 Submittal Date -- a-' I -7 Project Address: 3PLcE SIV r MAR 2 7 2017Contact: le- lc( ala5 Ph: q-1 — Fax: Email: \ o Q e ctC . aM Trades encompassed in revision: 0 Building Plumbing Electrical Mechanical Life Safety Waste Water Department Utilities Waste Water Planning Engineering Fire Prevention 11 Building BY: General description of revision: adb N0,,J q.kJJ- ONs ROUTING INFORMATION Approvals i w NAv'i G i Revision M q/ City of Sanford Response to Comments Building & Fire Prevention DivisionP9 Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Permit # 11- 230 Project Address Contact: Ph: L(,-,-1 — 333- 1150 Email: 40`2 e Vv,C-J aeC, Trades encompassed in revision: 0 Building 14 Plumbing Electrical Mechanical Life Safety Waste Water Submittal Date 31 O3"1 I -7 ECEIVE' r MAR 21 2011 Fax: General description of revision: ROUTING INFORMATION Department Approvals Utilities Waste Water Planning Engineering Fire Prevention Building k 6,19 M r N c c a 19int n FIRE SYSTEMS 699 Aero Lane, Sanford, FL 32771 TEL: 407-585-3200 FAX: 407-585-3277 www.wigintonfiresystems.com PERMIT 2010771 Gafte' sh North " w WIGINTON FIRE PROTECTION ENGINEERING, INC. HYDRANT FLOW TEST FORM Contract No. 2010771 Name & Location: Ganesh North Buildings One - Five, Monroe Road, Sanford, FL 32771 Description of Property: Authority Having Juristiction: City of Sanford FLOW TEST DATA Test No.: 1 By: WFS Time: 9:00 AM Date: 8/2/2016 STATIC PRESS. P.S.I. RESID. PRESS. P.S.I. PITOT PRESS. P.S.I. FLOW TABLES C= HYDRANT NOZZLE COEF. FLOW OPENING INCHES HYDRANT NO. BUTT REMARKS NUMBER 60 50 1,840 0.9 2 2'/i ' o 1 lllola,a no+ ILi 1111[: 9100 MIp1 1 JlE IO I Mrs S1 S I RLL I RMA, 10 .12 ry¢ 1.60114Wrr.) R RA. 1110iW , GAUGE CALIBRATION TRUE STATIC PITOT CHANGE WEIGHT RESIDUAL GAUGE OBSERV. P. S. I. GAUGE TEST DATA CORRECTED STATIC PRESS. P.S.I. RESID. PRESS. P.S.I. THEOR. FLOW C= ACTUAL ACTUAL COEF. FLOW C= G.P.M. o I 1 o ocm Ce o 1 lllola,a no+ ILi 1111[: 9100 MIp1 1 JlE IO I Mrs SKETCH OF TEST LOCATION J I r1A4C1$$U$ AVENUE o I 1 o ocm Ce o 1 lllola,a no+ ILi 1111[: 9100 MIp1 1 JlE IO I Mrs S1 S I RLL I RMA, 10 .12 ry¢ 1.60114Wrr.) R RA. 1110iW , Elevation of Test Hydrant Page 1 Form W FPE 500 NOTE CONCERNING FIRE PUMP CURVE USED FOR HYDRAULIC CALCULATIONS: The proposed electric, vertical in-line fire pump being provided for this project will have a rating of 1,250 gpm at 110 psi. Typically, a factory performance test curve is obtained and input into hydraulic calculations to reflect the true performance capabilities of the fire pump (in lieu of an NFPA rated curve). A factory performance test curve was not available for the proposed 110 psi rated fire pump, but a test curve was available for a similar 105 psi rated fire pump. Both the 110 psi rated fire pump and the 105 psi rated fire pump having almost identical flow characteristics, an additional 4 psi has been added to each flow point used from the 105 psi factory performance test curve that is included with these hydraulic calculations. mmmmmmmmmmm mm mm mmmmmmm mmmmmmm mmmmmm mmmmmmm mmmmmmm mmmmmmm mm mm ORDER INFORMATION Customer: HYDRO TECHNOLOGIES Serial No: FP-CO145156-01 Job: 314258 TEST INFORMATION Positive Pressure Test Venturi Meter: 8" Venturi Constant: 192.78 Discharge Dia: 8.00 Suction Dia: 8.00 Discharge Guage Elev.(Zd): 0.00 Suction Guage Elev. (Zs): 0.00 Pressure Ga: 30OPS1 Panel No.: I WaterTemp Test Data No' Pd (PSI) Ps (PSI). kW NI ' h("H20 I, 140.00 16.20 35.20 1,792.00 0.00 2 _ 134_00_ 16.00 64.40 1,788.001 11.00 3 128.00 15.40_ 73.00 1,785.00 27.00 43.004121.00 14.60 79_20 1,784.00 5, 115.00 14.20 83.00 1,784.00 55.00 6. 109.00 13.80 85.40 1,784.00 66.00 7 88.00 12.8_0 89.40_1,778.00 95.0_0 8 83.00 12.60 90.00 1,778.00 100.00 Continents: UUFM RATING IOOHP PA'T'TERSON PUMP COMPANY PUMP DATA Pump Size & Type:8X8X 18VIPDI impeller Pattern: D05-104403 Impeller Diameter: 16.375 Vane Tips: .875 Stages: I TEST DRIVER INFORMATION_. HP: 100 - RPM: 1775 Manufacturer: WEG Serial No.: 1030691230 Volts: 460 Amps: 118 S.F.: 1.15 Eff.(.00): 0.941 Calenlatorl rlar., RATING (Design) GPM. I:5O' FTHD:2 t3 . IoS-ZZ f%1 RPM (N2); 1780 (-F N Psi) SECONDARY RATINGS GPM: 1,875.00, 0.00 FT HD: 157.95, 0.00 Data Collected by: L J Test Date: Feb -26-2016 Test No.: I 1 Q 1 (GPM) 0.00_1 H I (FT) 285_98 whp i ehp 0.00 47.18_ bhp I i npump 44.401 0.00 639.381 1 1,001.71 272.58 260_11 44.01 86.33 65.801 97.86 81.231 54.18- 92.081 71.45 264.14 245.78 78.46 106.17 99.90 , 78.54 1,429.69 L 1,566.15 232.85 219.91 I 173.7 I 162.62 84.07 _ 111.26 86.97 114.48 104.70 _ 80.3_0 107.72 i 80.74 112.771 _ 73.09 I 1 13.531 69.74 1,878.991 1,927.801 82.42' 119.84 79.17 I 120.64 Calculated Data at Rated Speed Q2 (GPM) I H2 (FT) bhp2 0,0.9 636.52 F.16 (%%.103.52 270.1-5270.151 80.15 P r e' .GS /IZ,o091.31 1 ftN1. 8I.I0, 4jD5.-%;99.23 k=V903.99 I 3 9/ e07.00 I 7S V 13.15 j 1,929.971 162.99 113.91 NSIONS IN () ARE FOR PRIMARY N hM= Ml PATTERSON PUMP COMPANY A SUBSIDIARY OF THE GORMAN-RUPP COMPANY TITLE DRAWING NUMBER REV UUFM NAMEPLATE E-15085 6 IN-LINE PUMPS) PATTERN NUMBER SHEET OF SCALE PART NUMBER 1 1 1:1 23007607DRAWNCHECKEDAPPROVEDGATE CHILOS AP AP SEP. 27,199%" 5NSIONS ARE IN INCHES AND SECONDARY DIMENSIONS, SHOWN IN ( ], ARE IN MILLIMETER: e cl&us LISTED ® M ago A SUBSIDIARY OF THE GORMAN-RUPP CO. APPROVED TOCCOA,GEORGIA CENTRIFUGAL FIRE PUMP IN-LINE SIZE -TYPE NO. STGS. SERIAL NO. • 8X8X18VIPD1 FP -C0145156 MAX.B.H.P. 113.9 MAX. SUCT. 178 P.S.I. 1.50 CAP. G.P.M. R.P.M. PSIG MAX. PSIG PSIG IMP. DIA. 1250 1780 105 122 761 16.375 THIS DOCUMENT CONTAINS DESIGNS AND OTHER PRIMARYINFORMATIONWHICHARETHECONFIDENTIALPROPERTYTOLERANCES OF PATTERSON PUMP COMPANY. THE RECIPIENT EXCEPTAs NOTE01 ACKNOWLEDGES THAT THIS IS FURNISHED FOR ITS 2 PLC DEC. t.03" PRIVATE USE AND UPON THE EXPRESS AGREEMENT THAT IT WILL NOT REPRODUCE. COPY, EXHIBIT OR LEND IT IN 3 PLC DEC. t.005" WHOLE OR IN PART FOR ANY PURPOSE WHAT SO EVER WITHOUT THE PRIOR WRITTEN CONSENT OF PATTERSON ANGULAR t 1" PUMP COMPANY. TORCH C UT t.06" MACHNIST NOTE: BREAK ALL SHARP OORNERSTO A.02 X V CHAMFER FABRICATIONtcATtoNUPTos^ t.06" REV ECR DATE e' 6" TO 24" t.12" NSIONS IN () ARE FOR PRIMARY N hM= Ml PATTERSON PUMP COMPANY A SUBSIDIARY OF THE GORMAN-RUPP COMPANY TITLE DRAWING NUMBER REV UUFM NAMEPLATE E-15085 6 IN-LINE PUMPS) PATTERN NUMBER SHEET OF SCALE PART NUMBER 1 1 1:1 23007607DRAWNCHECKEDAPPROVEDGATE CHILOS AP AP SEP. 27,199%" 5NSIONS ARE IN INCHES AND SECONDARY DIMENSIONS, SHOWN IN ( ], ARE IN MILLIMETER: e cl&us LISTED ® M ago A SUBSIDIARY OF THE GORMAN-RUPP CO. APPROVED TOCCOA,GEORGIA CENTRIFUGAL FIRE PUMP IN-LINE SIZE -TYPE NO. STGS. SERIAL NO. • 8X8X18VIPD1 FP -C0145156 MAX.B.H.P. 113.9 MAX. SUCT. 178 P.S.I. 1.50 CAP. G.P.M. R.P.M. PSIG MAX. PSIG PSIG IMP. DIA. 1250 1780 105 122 761 16.375 A Subsidlary of The Gomuw-Rupp Company HYDROSTATIC PRESSURE TEST REPORT Serial Number P?(b1y5l!1(, Pump Model Test Pressure (Psi) V66 Test Duration (MIN.) 1(; Test Liquid Water, Temperature ranging from 50 t0 70 degrees F Test Facility L`Y Small Pump Assy Gauge S/N Large Pump Assy Gauge S/N Other Gauge S/N Test Results L'7 PASS FAIL COMMENTS: Tested By: ` Witnessed By: f Date: 'L'-'- h -- ( E N/A 0 400 f- 39, W U- 3C 0 a 25 J 0 20 15 10 51 l 20( U-1 0 15C w 100 0 Y 50 a m 0 PATTERSON PUMP COMPANY A Subsidiary of the Gorman -Rupp Camvany P. 0. Box 790 Toccoo, Georaia 30577 Telephone 706-886-2101 Fox 706-886-0023 o 14 1" DIA. I I I 1 780 RPMq125075 wv- "U, ovi,yunNS. com GPM PSI to 137 PSI 173' to 317') I MODEL 8x8x18A VIP IMP. D05-104403 i CURVE A05-116622 F DIA. I I 82- 5- 83.5% 1 U- I 120 z 18" 40 o DIA. I 14.'i_QIA_ N P H_ I j I - I I j 400 Ann r- %J 4 v LOUD GPM UNIT PPC ORDER No. JOB CUSTOMER PO No. Ganesh North b PUMP -NOW -18102— CAPACITY ilk6010 G.P.M. @92 FT. FT. HD. MOTOR ODP MANE Weg FRA*S JPV 125 H,P_ 3 PHASE60 CYCLL'60 VdL7$0 John M. Bolin R.P.M. t CERTIFIED BY: ger DATE12114/16 UNIT DIMENSIONS MOTOR FRAME C D BG UNIT WEIGHT 286 JPV 7B1 1 T 348 1:91ft 4 120 Lo 545 KGS 324 JPV 813 151/8 20 7/16131 509.5 SWOWS 384 326 JPV ala 851 151/8 3w-—Wy--0-TO 2013/16 1385 LBS GS 364 JPV 351/489T.T 177/8 2111116L 8 BS6B5KGS 365 JPV 351/4899-3 17718 77- 2111/16 551 1538 LBS 700 GS 404 JPV 38112 978 177/8 454 235116 1730 LBS 786 NGS92 405 JPV 3181/2978 17718 454 235fflk 185 592 6 3 KG 1113116 405 TCZ 38112 17 7/8 / 6 1890 LBS 300.6 878 054 592 659 KGS UNIT WEIGHi PUMP AND MOTOR COMBINED. " '" L 010254.0 S- Q2 BLAS fF 08 1263.2 SUCTION 013 1/2 / 343 FLANGE 8x 07/8122.2 BOLT HOLES EO. SP. ON A 011314 / 298.5 B.C. B.C. STRADDLES 4i 1/4.10 UNC X 1' DI BOLT HOLES 021b 9 B.C. D MOUNTING FOOT DETAILA, 3/4' NPT c NOTE: 1) ALL DIMENSIONS ARE N• 1/4'/ 6.4mm (EXCEPT FOR FLANGE DRILLING). 2) PRIMARY DIMENSIONS ARE INCHES. SECONDARY DIMENSIONS ARE MILLIMETERS. ROTATION 3/4' NPT ttt U 081203.2 DISCHARGE 0151381 FLANGE 8x 07/8 / 22.2 BOLT HOLES EO. SP. ON A 011 3/44.298.5 B.C. PLAN VIEW B.C. STRADDLES fL CLEARANCE RECOMMENDED TO REMOVE ROTATING ASSY. 5' 150# ANSI FLANGE DIMENSIONS SEE MOUNTING FOOT DETAIL) OUTLINE DIMENSIONS LCO2-118338 1Y BURROW FOR oxA r., DATE PATTERSON PUMP COMPANY 8 X 8 X 18 VIP mcaudell NOV. 24, 2010ACAIWAIAWIDWAIN Sc4F AiFAYpW/ VARIOUS MOTORS NONE AP i PjagoM L oin FIRE SYSTEMS Wiginton Fire Systems 699 Aero Lane Sanford, FL 32771 407-585-3200 Job Name 2010771 - B1S1RA1' Drawing FP2/FP3 Location BUILDING ONE Remote Area B1S1RA1 Contract 2010771 Data File 2010771 - B1S1RA1.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 Wiginton Fire Systems 2010771-61 S1RA1 Page 1 Date 5-19-17 Project name: GANESH NORTH Location: BUILDING ONE Drawing no: FP2/FP3 Date: 5-19-17 Design HYDRAULIC CALCULATIONS for Remote area number: B1S1RA1 Remote area location: SYSTEM ONE Occupancy classification: HIGH PILED STORAGE Density: 52 PSI - Gpm/SgFt Area of application: 12 HEADS - Sq Ft Coverage per sprinkler. 100 MAX - SgFt Type of sprinklers calculated: 16.8K ESFR PENDENT No. of sprinklers calculated. 12 In -rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 1709.991 - GPM @ 32.419 - Psi Type of system: WET Volume of '&Y or preaction system? N/A - Gal ' Water supply information Date: 8-2-16 Location: ALONG W. 1ST STREET Source: WFS Name of contractor. WIGINTON FIRE SYSTEMS Address: 699 AERO LANE, SANFORD, FL 32771 Phone number: 407-585-3200 Name of designer: W. AMMONS Authority having jurisdiction: CITY OF SANFORD Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Revision: 50.52.1 Water ply Curve C Wiginton Fire Systems Page 2 2010771 - 131 S1 RA1 Date 5-19-17 City Water Supply: C1 - Static Pressure 60 C2 - Residual Pressure: 50 C2 - Residual Flow : 1840 City Water Adjusted to Pump Inlet for Pf - Elev - Hose Flow P2 - Pump Rated Flow Al - Adjusted Static: 54.436 A2 - Adj Resid 33.185 @ 1261.31 A3 - Adj Resid 10.52 @ 1881.1 210 196 182 p 168 R 154 E 140 S 126 S 112 U 98 R 84 E 70 56 42 28 14 Al +1121 1 Pump Data: P1 - Pump Churn Pressure 126.18 P2 - Pump Rated Pressure 109.95 P2 - Pump Rated Flow 1261.31 P3 - Pump Pressure @ Max Flow 79.39 P3 - Pump Max Flow 1881.1 City Residual Flow @ 0 4846.63 City Residual Flow @ 20 3892.4 City Water @ 150% of Pump 49.58 A2+P2 D2 LUU 41JU bUU 8UU 1000 1200 1400 1600 FLOW N^1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Demand: 01 - Elevation 14.890 D2 - System Flow 1459.99 D2 - System Pressure 110.647 Hose ( Demand) D3 - System Demand 1459.99 Hose ( Adj City) 250 Safety Margin 18.849 1800 Flow D' -3m Wiginton Fire Systems 2010771 - 61 S 1 RA1 Page 3 Date 5-19-17 122.7244.5 488.7 793.8 897.7 981.6 1053.5 11223 1196.2 1282.2 1385 1460 1460 1460H3 +-H4 +-100+-101+-103t-105+-107+-109+- III +-113+-115+-117+-119+-121+-123E-125+-127+-129+-131+-133+-135+-137+-139+-141+-143-TR1+-BR1+-PO244.5 244.5 732 848.8 941.7 1018.5 1087.7 1158.1 1237.4 1331.3 1460 1460 1460 1460 1710 1710 PI +- SPIG- UG3+- UG4+- UG5+- UG6e- TEST 1460 1710 1710 1.5 241.7 241.7 728 611.2 518.3 441.5 372.2 301.9 222.6 128.7 75 75 H3 - H2 +- H1 +- 200 +- 201 +- 203 +- 205 +- 207 +- 209 +- 211 +- 213 +- 215 +- 217 +- 219 +- 221 +- 223 +- 225 +- 227 +- 229 i- 231 +- 233 +- 235 +- 237 +- 236 +- 136 +- 137 1198 241.7 484 666.2 562.3 478.4 406.5 337.7 263.8 177.8 75 75 242.2 120.2 122.4 244.2 203 - 202 - H5 -+ H6 H7 +- H8 +- 102 +- 103 1 2422 1.2 244.2 1 1 484 1 488.7 1 244 121.8 121.3 24:13 205 • 204 . H9 - HIO-rH11 H12+- 104 +- 105 1 244 0.2 243.3 1 728 1 61.8 61.8 207 +- 206 +- 106 +- 107 1 61.8 1 1 666.2 1 793.8 1 54.9 54.0 209 +- 208 +- 108 +- 109 1 54.9 1 1 611.2 1 848.8 1 49 491 211+- 210+- 1104- 111 1 49 1 1 562.3 1 897.7 1 43.9 43.0 213+- 212+- 1124- 113 T 43.9 1 1 518.3 1 941.7 1 399 39.0 215+- 214+- 114+- 115 T 39.9 1 1 478.4 1 981.6 1 36.9 36.0 217+- 216+- 116+- 117 T 36.9 1 1 441.5 1 1018.5 1 35 351 219 +- 218 +- 118 +- 119 1 35 1 1 406.5 1 1053.5 1 34.2 34.g 221 +- 220 +- 120+- 121 t 342 1 1 372.2 1 1087.7 1 34.5 34.0 223+- 222 +- 122 +- 123 1 34.5 1 1 337.7 1 1122.3 1 35.9 35.0 225 +- 224 +- 124 +- 125 1 35.9 1 1 301.9 1 11581 Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow U 3m Wiginton Fire Systems 2010771 - B1S1RA1 1 38.1 38.1 227 F- 226 +-126 . 127 T 38.1 T 1 263.8 1 1196.2 1 41.1 41.1 229 228 4-128 <- 129 1 41.1 j 1 222.6 1 1237.4 1 44.8 44 f 231 i 230 +- 130 . 131 1 44.8 1 1 177.8 1 1282.2 1 49.1 49.1 233 <- 232 t 132 e- 133 1 49.1 1 1 128.7 1 1331.3 1 53.7 SIT 235 234 +- 134 t 135 53.7 Computer Programs by Hydratec Inc. Revision: 50.52.1 Page 4 Date 5-19-17 Fittings -d Summary Wiginton Fire Systems Page 5 2010771 - 61 S1RA1 Date 5-19-17 Fitting Legend Abbrev. Name '/2 '/. 1 1'% 1 %: 2 2%: 3 3'/2 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0E90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61GGenericGateValve00000111122345678101113LLongTurnElbow1122234556891316182427303440SGenericSwingCheckValve4557911141619222732455565768798109130T90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121V90'Ell Firelock #001 0 0 0 0. 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0X90'Tee-BranchFirelock002 0 0 0 0 0 8.5 10.8 13 0 16 _ 21 25 33 0 0 0 0 0 0 0ZafAmes3000SSFittinggeneratesaFixedLossBasedonFlow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD Wiginton Fire Systems Page 6 2010771 - B1S1RA1 Date 5-19-17 lode Elevation K -Fact Pt Pn Flow Density Area Press No. Actual Actual Req, _ H3 36.38 16.8 52.0 na 121.15 0.1 100 52.0 H4 35.97 16.8 52.55 na 121.78 0.1 100 52.0 100 32.08 70.23 na 101 29.37 74.25 na 103 29.37 74.26 na 105 29.37 74.32 na 107 29.37 74.45 na 109 29.37 74.6. na 111 29.37 74.77 na 113 29.37 74.96 na 115 29.37 75.16 na 117 29.37 75.38 na 119 29.37 75.62 na 121 29.37 75.87 na 123 29.37 76.14 na 125 29.37 76.42 na 127 29.37 76.72 na 129 29.37 77.04 na 131 29.37 77.37 na 133 29.37 77.74 na 135 29.37 78.12 na 137 29.54 79.96 na 139 -,,29.55 88.25 na 141 29.55 89.88 na 143 29.55 92.31 na TR1 29.55 93.29 na BRI 2.0 109.57 na PO 2.0 110.65 na PI 2.0 26.46 na PIG -3.0 29.35 na G3 -3.0 32.65 na 250.0 UG4 -3.0 43.32 na UG5 -3.0 48.44 na UG6 -3.0 52.23 na TEST 2.0 51.27 na H2 36.03 16.8 52.15 na 121.32 0.1 100 52.0 H1 35.62 16.8 52.68 na 121.94 0.1 100 52.0 200 32.09 66.13 na 201 29.38 70.09 na 203 29.38 70.2 na 205 29.38 70.61 na 207 29.38 71.47 na 209 29.38 72.21 na 211 29.38 72.83 na 213 29.38 73.37 na 215 29.38 73.83 na 217 29.38 74.23 na 219 29.38 74.57 na 221 29.38 74.87 na 223• 29.38 75.12 na 225 29.38 75.33 na 227 29.38 75.5 na 229 29.38 75.63 na 231 29.38 75.73 na 233 29.38 75.79 na 235 29.38 75.83 na 237 29.38 75.84 na 236 32.09 74.98 na 136 32.25 78.47 na 202 32.09 66.24 na H5 35.62 16.8 52.74 na 122.01 0.1 100 52.0 H6 36.03 16.8 52.2 na 121.39 0.1 100 52.0 Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - Standard Wiginton Fire Systems Page 7 2010771 - B1S1RA1 Date 5-19-17 Node Elevation K -Fact Pt Pn Flow Density Area Press No. - - - Actual Actual Req.. H7 36.38 16.8 52.05 na 121.21 0.1 100 52.0 H8 35.97 16.8 52.6 na 121.84 0.1 100 52.010232.08 70.26 na 204 32.09 66.6 na H9 35.62 16.8 52.94 na 122.24 0.1 100 52.0H1036.03 16.8 52.4 na 121.61 0.1 100 52.0H1136.38 16.8 52.25 na 121.44 0.1 100 52.0 H12 35.97 16.8 52.79 na 122.06 0.1 100 52.010432.08 70.34 na 206 32.09 70.52 na 106 32.08 73.06 na 208 32.09 71.21 na 108 32.08 73.25 na 210 32.09 71.81 na 110 32.08 73.45 na 212 32.09 72.32 na 112 32.08 73.67 na 214 32.09 72.76 na 114 32.08 73.89 na 216 32.09 73.14 na 116 32.08 74.12 na 218 32.09 73.48 na 118 32.08 74.37 na d 220 32.09 73.77 na 120 32.08 74.62 na 222 32.09 74.02 na 122 32.08 74.89 na 224 32.09 74.24 na 124 32.08 75.16 na 226 32.09 74.42 na 126 32.08 75.45 na 228 32.09 74.56 na 128 32.08 75.76 na 230 32.09 74.68 na 130 32.08 76.08 na 232 32.09 74.76 na 132 32.08 76.42 na 234 32.09 74.82 na 134 32.08 76.78 na The maximum velocity is 16.05 and it occurs in the pipe between nodes 205 and 207 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 8 2010771 - B1S1RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn EQUIVALENT K'S REMOTE HEAD TO SUPPLY H3 122.68 2.703 0.0 10.000 52.000 K Factor = 16.80 to 6.385 120.0 0.0 0.0 0.178 0.0 120.0 H4 122.68 0.0371 0.0 10.000 0.371 Vel = 6.86 H4 121.78 2.703 X 16.786 103.540 52.549 K Factor = 16.80 to 120.0 0.0 16.786 1.685 119 1018.5 100 244.46 0.1330 0.0 120.326 16.000 Vel = 13.67 100 0.0 2.703 T 18.651 2.710 70.234 8.330 76.136 to 120.0 0.0 18.651 1.174 0.0 0.0 101 244.46 0.1330 0.0 21.361 2.840 Vel = 13.67 101 0.0 6.385 0.0 8.330 74.248 8.330 76.418 to 120.0 0.0 0.0 0.0 0.0 0.0 103 244.46 0.0019 0.0 8.330 0.016 _ Vel = 0.299 103 2.44.22 6.385 I'd 0.0 8.330,;,- 74.264 to 120.0 0.0 0.0 0.0 1_05_ 488.68 0.007 - 0073 0.0 8.330_ 0.061 __ Vel = 4.90 105 243.32 6.385 0.0 8.330 74.325 to 120.0 0.0 0.0 0.0 107 732.0_ 0.0154 0.0 8.330 0.128 _ Vel =_ 7.3_3 107 61.83 6.385 0.0 8.330 74.453 to 120.0 0.0 0.0 0.0 109 793.83 0.0179 0.0 8.330 0.149 Vel = 7.95 109 54.92 6.385 0.0 8.330 74.602 to 120.0 0.0 0.0 0.0 Ili--- 848.7.5 0.0202_ 0.0 _ 8.330 0.168 _--_- Vel = 8.50 111 48.96 6.385 0.0 8.330 74.770 to 120.0 0.0 0.0 0.0 113 897.71 0.0224 0.0 8.330 0.187 Vel = 9.00 113 to 115 43.94 941.65 6.385 120.0 0.0246 0.0 0.0 0.0 8.330 0.0 8.330 74.957 0.0 0.205 Vel = 9.44 115 39.92 6.385 0.0 8.330 75.162 to 0.0 120.0 0.0 0.0 0.0 117 981.57 0.0264 0.0 8.330 0.220 Vel = 9.84 117 36.93 6.385 0.0 8.330 75.382 • to 120.0 0.0 0.0 0.0 119 1018.5 0.0283 0.0 8.330 0.236 Vel = 10.21 119 35.02 6.385 0.0 8.330 75.618 to 120.0 0.0 0.0 0.0 12_1_ _- 10.53.52 0.03_01 - 0.0 8.330 0.251 Vel = 10.56 121 34.22 6.385 0.0 8.330 75.869 to 120.0 0.0 0.0 0.0 123 1087.74 0.0321 0.0 8.330 0.267 Vel = 10.90 123 34.53 6.385 0.0 8.330 76.136 to 120.0 0.0 0.0 0.0 125 11.22.27 0.0339 _ 0.0 8.330 0.282 Vel = 11.25 125 35.85 6.385 0.0 8.330 76.418 to 120.0 0.0 0.0 0.0 127 1158.12 0.0359 0.0 8.330 0.299 Vel = 11.60 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems 2010771 - B1S1RA1 Page 9 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv ""'••` Notes ""'• Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 127 38.11 6.385 18.849 0.0 8.330 76.717 - - to Pressure @ Pump Inlet _ _ 120.0 PI 0.0 8.249 0.0 0.0 0.0 SPIG 1459.99 0.0158 0.0 45.871 0.726 Vel = 8.76 129 1196.23 0.0382 77.87 0.0 8.330 0.318 Vel = 11.99 129 41.15 6.385 0.0 8.330 77.035 to 120.0 0.0 0.0 0.0 131 1237.38 0.0406 0.0 8.330 0.338 Vel = 12.40 131 44.84 6.385 0.0 8.330 77.373 to 120.0 0.0 0.0 0.0 133 1282.22 0.0435 0.0 8.330 0.362 Vel = 12.85 133 49.07 6.385 0.0 8.330 77.735 to 120.0 0.0 0.0 0.0 135 1331.29 0.0465 0.0 8.330 0.387 Vel = 13.34 135 53.70 6.385 2V 25.691 12.510 78.122 to 120.0 0.0 25.691 0.074 137 1384.99 0.0500 _ L 0.0 38.201 1.911_ Vel = 13.88 137 75.00 6.385 Y V 12.845 137.500 79.959 to 120.0 0.0 12.845 0.004 139 _ 1459.99 0.0_55_2 0.0 150.345 8.292 _ Vel = 14.63 139 0.0 6.385 V 12.845 16.670 88.247 to 120.0 0.0 12.845 0.0 141 1459.99 0.0552 0.0 29.515 1.628 Vel = 14.63 141 0.0 6.385 V 12.845 31.250 89.875 to 120.0 0.0 12.845 0.0 143 1459.99 0.0552 0.0 44.095 2.432 Vel = 14.63 143 0.0 6.385 V 12.845 4.958 92.307 to 120.0 0.0 12.845 0.0 TR1 1459.99 0.0552 0.0 17.803 0.982 Vel = 14.63 TR1 0.0 6.385 T 38.536 27.500 93.289 to 120.0 B 12.845 51.381 11.932 BR1 1459.99 0.0551 0.0 78.881 4.350 Vel = 14.63 BR1 0.0 8.249 B 13.345 4.500 109.571 to 120.0 S 50.044 63.389 0.0 PO 1459.99 0.0158 0.0 67.889 1.076 Vel = 8.76 0.0 1459.99 110.647 K Factor = 138.80 System Demand Pressure 110.647 Safety Margin 18.849 Continuation Pressure 129.496 Pressure @ Pump Outlet 129.496 Pressure From Pump Curve 103.040 Pressure @ Pump Inlet _ _ 26.456 PI 0.0 8.249 T 38.923 2.500 26.456 to 120.0 G 4.448 43.371 2.166 SPIG 1459.99 0.0158 0.0 45.871 0.726 Vel = 8.76 SPIG 0.0 8.27 to T140.0 UG3 1459.99 0.0118 UG3 250.00 8.27 to 52.413 140.0 UG4 1709.99 0.0158 E 26.955 195.000 29.348 T 52.413 85.358 0.0 G 5.99 280.358 3.299 T 52.413 300.000 32.647 Zaf 0.0 130.283 3.893 4L 77.87 430.283 6.782 Computer Programs by Hydratec Inc. Revision: 50.52.1 Vel = 8.72 Qa = 250 Fixed Loss = 3.893 Vel = 10.21 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 10 2010771 - B1 S1RA1 Date 5-19-17 Hyd. Oa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv '""'"" Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UG4 0.0 10.28 T 71.092 865.000 43.322 to 140.0 0.0 71.092 0.0 UG5 1709.99 0.0055 0.0 936.092 5.114 Vel = 6.61 UG5 0.0 12.34 T 88.164 1600.000 48.436 to H3 140.0 0.0 88.164 0.0 UG6 1709.99 0.0022 0.0 1688.164 3.789 Vel = 4.59 UG6 0.0 12.34 T 88.164 450.000 52.225 to 0.0 _ 140.0 0.0 88.164 2.166 TEST 1709.99 0.0022 0.0 538.164 1.208 Vel = 4.59 52.152 0.0 to 120.0 0.0 0.0 1709.99 H1 ___ 51.267 K Factor = 238.82 NEW PATH H3 1.53 2.703 0.0 10.000 52.000 to 120.0 0.0 0.0 0.152 d H2 1.53 0.0 _ Q.0 10.000 1.0.0 Vel = 0.09 H2 121.32 2.703 0.0 10.000 52.152 K Factor = 16.80 to 120.0 0.0 0.0 0.178 H1 ___ 119.79 0.0354 _ 0.0 _ 10.000 0.354 _ Vel = 6.70_ H1 121.94 2.703 X 16.786 74.740 52.684 K Factor = 16.80 to 120.0 0.0 16.786 1.529 200 241.73 0.1302 0.0 91.526 11.920 Vel = 13.52 200 0.0 2.703 T 18.651 2.710 66.133 to 120.0 0.0 18.651 1.174 201 _ 241.73 0.1302 _ 0.0 _ _ 21.361 2.782 _ Vel_ = 13.52__ 201 0.0 4.304 0.0 8.330 70.089 to 120.0 0.0 0.0 0.0 203 241.73 0.0134 0.0 8.330 0.112 Vel = 5.33 203 242.23 4.304 0.0 8.330 70.201 to 120.0 0.0 0.0 0.0 205 483.96 0.0489 0.0 8.330 0.407 Vel = 10.67 205 244.03 4.304 0.0 8.330 70.608 to 120.0 0.0 0.0 0.0 207 727.99 0.1040 0.0 8.330 0.866 Vel = 16.05 207 61.83 4.304 0.0 8.330 71.474 to 120.0 0.0 0.0 0.0 209 666.16 0.0881 0.0 8.330 0.734 Vel = 14.69 209 54.92 4.304 0.0 8.330 72.208 to 120.0 0.0 0.0 0.0 211 611.24 0.0752 0.0 8.330 0.626 Vel = 13.48 211 48.96 4.304 0.0 8.330 72.834 to 120.0 0.0 0.0 0.0 213_ 562.28 0.0645 0.0 8.330 0.537_ Vel = 12.40 213 43.94 4.304 0.0 8.330 73.371 to 120.0 0.0 0.0 0.0 215 518.34 0.0555 0.0 8.330 0.462 Vel = 11.43 215 39.92 4.304 0.0 8.330 73.833 0 120.0 0.0 0.0 0.0 217 478.42 0.0478 0.0 8.330 0.398 Vel = 10.55 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 11 2010771 - B1S1RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 217 -36.93 4.304 0.0 8.330 74.231 to 120.0 0.0 0.0 0.0 219 441.49 0.0412 0.0 8.330 0.343 Vel = 9.74 219 35.02 4.304 0.0 8.330 74.574 to to 0.0 120.0 0.0 0.0 0.0 0.0149 0.0 221 406.47 0.0354 0.0 8.330 0.295 Vel = 8.96 221 34.22 4.304 0.0 8.330 74.869 137 75.0 to 0.0 120.0 0.0 0.0 0.0 16.786 1.529 223 372.25 0.0300 0.0 8.330 0.250 Vel = 8.21 223 34.53 4.304 0.0 8.330 75.119 to 120.0 0.0 0.0 0.0 225 337.72 0.0251 0.0 8.330 0.209 Vel = 7.45 225 35.85 4.304 0.0 8.330 75.328 to 120.0 0.0 0.0 0.0 227_ 301:87 0.0204 _ 0.0 - 8.330 w:; 0.170 -_ Vel = 227 38.11 4.304 0.0 8.330 75.498 6.66_ to 120.0 0.0 0.0 0.0 229 263.76 0.0158 0.0 8.330 0.132 Vel = 5.82 229 41.15 4.304 0.0 8.330 75.630 to 120.0 0.0 0.0 0.0 231 222.61 0.0116 0.0 8.330 0.097 Vel = 4.91 231 44.84 4.304 0.0 8.330 75.727 to 120.0 0.0 0.0 0.0 233 177.77 0.0076 0.0 8.330 0.063 Vel = 3.92 233 49.07 4.304 0.0 8.330 75.790 to 120.0 0.0 0.0 0.0 235 128.7 0.0043 _ 0.0 8.330_ 0.036 Vel = 2.84 235 53.70 4.304 0.0 8.330 75.826 to 120.0 0.0 0.0 0.0 237 75.0 0.0014 0.0 8.330 0.012 Vel = 1.65 237 0.0 2.703 T 18.651 2.710 75.838 to 120.0 0.0 18.651 1.174 236 75.0 0.0150 0.0 21.361 0.320 Vel = 4.19 236 0.0 2.703 2X 33.571 204.140 74.984 to 120.0 0.0 33.571 0.069 136, 75.0 0.0149 0.0 237.711 3.551 Vel = 4.19 136 0.0 2.703 T - 18.651 2.710 78.466 to 202 -242.23 120.0 0.0 18.651 1.174 137 75.0 0.0149 0.0 21.361 0.319 Vel = 4.19 0.0 75.00 7.9.959_ K_ Factor= 8.39 NEW PATH 203 -242.23 2.703 T 18.651 2.710 70.201 to 120.0 0.0 18.651 1.174 202 -242.23 0.1307 0.0 21.361 2.792 Vel = 13.54 202 0.0 2.703 X 16.786 74.740 66.235 0 120.0 0.0 16.786 1.529 H5 -242.23 0.1307 0.0 91.526 11.965 Vel = 13.54 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 12 2010771 - B1S1RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv •'••"' Notes '•"•' Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H5 122.01 2.703 X 16.786 0.0 10.000 52.741 K Factor = 16.80 to 0.0 120.0 1.685 0.0 0.0 0.178 0.0 H6 120.22 0.0358 0.0 0.0 10.000 0.358 Vel = 6.72 H6 121.38 2.703 0.0 0.0 10.000 52.205 K Factor = 16.80 to 0.0 _ 120.0 2.815 _ - --- Vel = 13.60 0.0 0.0 0.152 0.004 H7 1.16 0.0001 241.881 0.0 10.000 0.001 Vel = 0.06 H7 121.21 2.703 0.0 10.000 52.054 K Factor = 16.80 to 120.0 0.0 0.0 0.178 H8 122.37 0.0369 0.0 10.000 0.369 Vel = 6.84 H8 121.85 2.703 X 16.786 103.540 52.601 K Factor = 16.80 to 120.0 0.0 16.786 1.685 102 244.22 0.1327 O.0 120.326 15.970 Vel = 13.65 102 0.0 2.703 T 18.651 2.710 70.256 to 120.0 0.0 18.651 1.174 103 244.22,,___9.1327 0.0 21.361 _ 2_834 Vel = 13.65 244.22 74.264 K Factor= 28.34 NEW PATH 205 244.03 2.703 T 18.651 2.710 70.608 to 120.0 0.0 18.651 1.174 204 244.03 0.1325 _ 0.0 - 21.361 2.831 Vel = 13.64 204 0.0 2.703 X 16.786 74.740 66.603 to 120.0 0.0 16.786 1.529 244.03 0_.1325_______ 0.0 91.526 12.130 Vel = 3.64 H9 122.24 2.703 0.0 10.000 52.944 1 - K Facto = 16.80 to 120.0 0.0 0.0 0.178 H10 121.79 0.0366 0.0 10.000 0.366 Vel = 6.81 H10 121.61 2.703 0.0 10.000 52.400 K Factor = 16.80 to 120.0 0.0 0.0 0.152 H11 0.18 0.0 0.0 10.000 0.0 Vel = 0.01 H11 121.44 2.703 0.0 10.000 52.248 K Factor = 16.80 to 120.0 0.0 0.0 0.178 H12 121.26 0.0363 0.0 10.000 0.363 Vel = 6-78 H12 122.06 2.703 X 16.786 103.540 52.789 K Factor = 16.80 to 120.0 0.0 16.786 1.685 104 243.32 0.1318 0.0 120.326 15.862 Vel = 13.60 104 0.0 2.703 T 18.651 2.710 70.336 to 206 61.83 120.0 0.0 18.651 1.174 105 243.32 0.1318 0.0 _ 21.361--_ 2.815 _ - --- Vel = 13.60 0.0 243.32 74.325 K Factor= 28.22 NEW PATH 207 61.83 2.703 T 18.651 2.710 71.474 to 120.0 0.0 18.651 1.174 206 61.83 0.0104 0.0 21.361 0.223 Vel = 3.46 206 0.0 2.703 2X 33.571 208.310 70.523 to 120.0 0.0 33.571 0.004 106 61.83 0.0105 0.0 241.881 2.529 Vel = 3.46 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 13 2010771 - 61 S1 RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv "••••• Notes '••"• Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 106 0.0 2.703 T 18.651 2.710 73.056 to 120.0 0.0 18.651 1.174 107 61.83 0.0104 0.0 21.361 0.223 Vel = 3.46 0.0 61.83 74.453 K Factor= 7.17 NEW PATH 209 54.92 2.703 T 18.651 2.710 72.208 to to 48.96 120.0 0.0 18.651 1.174 208 54.92 0.0084 0.0 21.361 0.180 Vel = 3.07 208 0.0 2.703 2X 33.571 208.310 71.214 Vel = 2.74 to 0.0 120.0 0.0 33.571 0.004 241.881' 108 54.92 0.0084 0.0 241.881 2.031 Vel = 3.07_ 108 0.0 2.703 T 18.651 2.710 73.249 to 0.0 120.0 0.0 18.651 1.174 0109 _ 54.92 0:0084 _ 0,0,,1____.21,361 0,179 Vel,=! 3.07 111 0.0 0.0067 0.0 21.361 54.92 74.602 K Factor = 6.36 NEW PATH 43.94 2.703 T 18.651 2.710 73.371 to 211 48.96 2.703 --- T 18.651 2.710-- 72.834 ---- to 0.0 120.0 0.0 18.651 1.174 2.703 210 48.96 0.0068 0.0 21.361 0.146 Vel = 2.74 210 0.0 2.703 2X 33.571 208.310 71.806 241.881' to 112 120.0 0.0 33.571 0.004 73.665 110 _ 48.96 0.0068 _ _ 0.0 241.881 1.642 Vel = 2_._74 110 0.0 2.703 T 18.651 2.710 73.452 to 120.0 0.0 18.651 1.174 111 48.96 0.0067 0.0 21.361 0.144 Vel = 2.74 0.0 48.96 74.770 K Factor = 5-66 NEW PATH 213 43.94 2.703 T 18.651 2.710 73.371 to 120.0 0.0 18.651 1.174 212 43.94 0.0056 0.0 21.361 0.119 Vel = 2.46 212 0.0 2.703 2X 33.571 208.310 72.316 to 120.0 0.0 33.571 0.004 112 43.94 0.0056 0.0 241.881' 1.345 Vel = 2.46 112 0.0 2.703 T 18.651 2.710 73.665 to 120.0 0.0 18.651 1.174 113 43.94 0.0055 0.0 21.361 0.118 Vel = 2.46 0.0 43.94 NEW PATH 2.710 73.83321539.92 2.703 to 120.0 214 - - 39.92 0.0047 214 0.0 2.703 0 241.881 120.0 114 39.92 0.0047 74.957 T 18.651 2.710 73.833 0.0 18.651 1.174 0.0--21.361 33.571 0.100 - 2X- 208.310 72.759 0.0 33.571 0.004 0.0 241.881 1.125 Computer Programs by Hydratec Inc. Revision: 50.52.1 K Factor = 5.08 Vel = 2.23 Vel = 2.23 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 14 2010771 - B1S1RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 114 - - 0.0 - 2.703 T 18.651 2.710 - 73.888 - - - - - - - - to 120.0 0.0 18.651 1.174 115 39.92 0.0047 0.0 21.361 0.100 Vel = 2.23 0.0 39.92 75.162 K Factor= 4.60 NEW PATH 217 36.93 2.703 T 18.651 2.710 74.231 to 120.0 0.0 18.651 1.174 216 36.93 0.0040 0.0 21.361 0.086 Vel = 2.06 216 0.0 2.703 2X 33.571 208.310 73.143 to 120.0 0.0 33.571 0.004 116 36.93 0.0040 - -_- 0.0 241.881 _- 0.975 Vel = 2.06 116 0.0-_--2.703 T- 18.651 2.710 74.122 to 120.0 0.0 18.651 1.174 117,1 _ 36.93 0.0040• _ 0.0 121.36121.361 0.086 ., ,, Vel = 2.06 Computer Programs by Hydratec Inc. Revision: 50.52.1 0.0 36.93_ 75.382 K Factor = 4.25 NEW PATH 219 35.02 2.703 T 18.651 2.710 74.574 to ' 120.0 0.0 18.651 1.174 218 35.02 0.0037 0.0 21.361 0.078 Vel = 1.96 218 0.0 2.703 2X 33.571 208.310 73.478 to 120.0 0.0 33.571 0.004 118 35.02 0.00_37 0.0 241.881 0.884 Vel = 1.96 118 0.0 2.703 T 18.651 2.710 74.366 to 120.0 0.0 18.651 1.174 119 35.02 0.0037 0.0 21.361 0.078 Vel = 1.96 0.0 35.02 75.618 K Factor = 4.03 NEW PATH 221 34.22 2.703 T 18.651 2.710 74.869 to 120.0 0.0 18.651 1.174 220 34.22 0.0035 0.0 21.361 0.075 Vel = 1.91 220 0.0 2.703 2X 33.571 208.310 73.770 to 120.0 0.0 33.571 0.004 120 _ 34.22 0.0035 0.0_ 241.881 0.84_7 Vel = 1.91 120 0.0 2.703 T 18.651 2.710 74.621 to 120.0 0.0 18.651 1.174 121 34.22 0.003.5 0.0 21.361 0.074 Vel = 1.91 0.0 34.22 75.869 K Factor= 3.93 NEW PATH 223 34.53 2.703 T 18.651 2.710 75.119 to 120.0 0.0 18.651 1.174 222 _ 3.4.53_ 0.0036 0.0 21.361 0.076 Vel = 1.93 222 0.0 2.703 2X 33.571 208.310 74.021 to 120.0 0.0 33.571 0.004 122 34.53 0.0036 0.0 241.881 0.861 Vel = 1.93 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 15 2010771 - B1S1RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv "•"'• Notes ""'• Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 122 0.0 2.703 T 18.651 2.710 74.886 to 120.0 0.0 18.651 1.174 123 34.53 0.0036 0.0 21.361 0.076 0.0 to 34.53 76.136 NEW PATH Vel = 1.93 K Factor = 3.96 225 35.86 2.703 T 18.651 2.710 75.328 to to 0.0 120.0 1.174 0.0 18.651 1.174 0.0 224 35.86 0.0038 0.0 0.0 21.361 0.082 Vel = 2.00 224 0.0 2.703 2X 33.571 208.310 74.236 41.15 to 0.0 120.0 1.191 Vel = 2.30 0.0 33.571 0.004 124 35.86 0.0038 44.84 0.0 241.881 0.923 Vel = 2.00 124 0.0 2.703 T 18.651 2.710 75.163 to 44.84 120.0 0.0 _ 0.0 18.651 1.174 230 125 35.86 0.0038_ 0.0; r 21_.361 0.081 _ - _ Vel ,= 2.00 120.0 0.0 33.571 0.004 130 44.84 0.0 35.86 76.418 K Factor= 4.10 NEW PATH 227 38.11 2.703 T 18.651 2.710 75.498 to 120.0 0.0 18.651 1.174 226 - 38.11 0.0043 0.0 21.361 0.091 Vel = 2.13 226 0.0 2.703 2X 33.571 208.310 74.415 to 120.0 0.0 33.571 0.004 126 38.11 0.0043 0.0 241.881 1.0_33 Vel =2.13 126 0.0 2.703 T 18.651 2.710 75.452 to 120.0 0.0 18.651 1.174 127 38.11 0.0043 0.0 21.361 0.091 Vel = 2.13 0.0 38.11 76.717 K Factor = 4.35 NEW PATH 229 41.15 2.703 T 18.651 2.710 75.630 to to 120.0 0.0 18.651 1.174 228 41.15 0.0049 0.0 21.361 0.105 Vel = 2.30 228 0.0 2.703 2X 33.571 208.310 74.561 to 120.0 0.0 33.571 0.004 128 41.15 0.0049 0.0 241.881 1.191 Vel = 2.30 128 0.0 2.703 T 18.651 2.710 75.756 to 120.0 0.0 18.651 1.174 129 41.15 0.0049 0.0 21.361 0.105 Vel = 2.30 0.0 41.15 77.035 K Factor= 4.69 NEW PATH 231 44.84 2.703 T 18.651 2.710 75.727 to 120.0 0.0 18.651 1.174 230 44.84 0.0058 0.0 _ 21.361 0.123 Vel =_ 2.5.1__ 230 0.0 2.703 2X 33.571 208.310 74.676 to 120.0 0.0 33.571 0.004 130 44.84 0.0058 0.0 241.881 1.396 Vel = 2.51 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 16 2010771 - 61 S1 RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 130 0.0 2.703 T 18.651 2.710 76.076 to 120.0 0.0 18.651 1.174 131 44.84 0.0058 0.0 21.361 0.123 Vel = 2.51 0.0 44.84 77.373 K Factor= 5.10 NEW PATH 233 49.07 2.703 T 18.651 2.710 75.790 to 120.0 0.0 18.651 1.174 232 49.07 0.0068 0.0 21.361 0.146 Vel = 2.74 232 0.0 2.703 2X 33.571 208.310 74.762 to 120.0 0.0 33.571 0.004 132 49.07 0.0068 0.0 241.881 1.649 Vel = 2.74 132 0.0 2.703 T 18.651 2.710 76.415 to 120.0 0.0 18.651 1.174 133' 49.07 0.0068 0.0 0 21.361 0.146•,; Vel = 2:74 ;r 0.0 49.07___-- 77._73_5 _ - K Factor = 5.57_ NEW PATH 235 53.70 2.703 T 18.651 2.710 75.826 to 120.0 0.0 18.651 1.174 234 53.7 0.0081 0.0 21.361 0.172 Vel = 3.00 234 0.0 2.703 2X 33.571 208.310 74.824 to 120.0 0.0 33.571 0.004 134 53.7 0.0081 0.0 241.881 1.948 Vel = 3.00___ 134 0.0 2.703 T 18.651 2.710 76.776 to 120.0 0.0 18.651 1.174 135 53.7 0.0081 0.0 21.361 0.172 Vel = 3.00 0.0 53.70 78.122 K Factor= 6.08 Computer Programs by Hydratec Inc. Revision: 50.52.1 AutoPeaking Summary Wiginton Fire Systems Page 17 2010771 - B1S1RA1 Date 5-19-17 Auto Peaking Summary - List of Pipes for Area Calculated Flow Left Pressure Required Right Differential Left 10.000 1 1709.867 Side 0.099 Area Calculated 1 1709.991 Side 0.000 From To Length From To Length H4 100 103.540 H1 200 74.740 H8 102 103.540 202 H5 74.740 H12 104 103.540 204 H9 74.740 H4 100 103.540 H1 200 74.740 H8 102 103:540 202 H5 74.740 H12 104 103.540 204 H9 74.740 Flow Safety Pressure Required Margin Differential Left 10.000 1 1709.867 18.949 0.099 Area Calculated 1 1709.991 18.849 0.000 Right 10.000 1 1710.137 18.876 0.027 Typical Distance Between Heads = 10.000 Split Point Used in Worst Area Peaked = H3 Split Point Used in Area Calculated = H3 Computer Programs by Hydratec Inc. Revision: 50.52.1 W 0 0 omffl am FIRE SYSTEMS Wiginton Fire Systems 699 Aero Lane Sanford, FL 32771 407-585-3200 Job Name 2010771 - B1 S1RA2 Drawing FP10 Location BUILDING ONE Remote Area B1S1RA2 Contract 2010771 Data File 2010771 - B1S1RA2.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 W Wiginton Fire Systems 2010771 - B1S1RA2 Page 1 Date 5-19-17 Project name: GANESH NORTH Location: BUILDING ONE Drawing no: FP10 Date: 5-19-17 Design HYDRAULIC CALCULATIONS for Remote area number: B1S1RA2 Remote area location: SYSTEM ONE - SECOND FLOOR OFFICES Occupancy classification: OFFICES - LIGHT HAZARD Density: .10 - Gpm/SgFt Area of application: 980 - SgFt Coverage per sprinkler. 225 MAX - SgFt Type of sprinklers calculated. 5.6K PENDENT No. of sprinklers calculated. 10 In -rack demand. N/A - GPM Hose streams: 100 -GPM Total water required (including hose streams): 287.215 - GPM Type of system: WET Volume of dry or pie'action system: N/A - GbI" Water supply information Date: 8-2-16 Location: ALONG W. 1ST STREET Source: WFS Name of contractor. WIGINTON FIRE SYSTEMS Address: 699 AERO LANE, SANFORD, FL 32771 Phone number: 407-585-3200 Name of designer. W. AMMONS Authority having jurisdiction: CITY OF SANFORD Notes: (Include peaking information or gridded systems here.) @ 81.622 -Psi Computer Programs by Hydratec Inc. Revision: 50.52.1 Water )ly Curve C Wiginton Fire Systems Page 2 2010771 - B1S1RA2 Date 5-19-17 City Water Supply: C1 - Static Pressure : 60 C2 - Residual Pressure: 50 C2 - Residual Flow : 1840 City Water Adjusted to Pump Inlet for Pf - Elev - Hose Flow - Al - Adjusted Static: A2 - Adj Resid A3 - Adj Resid 56.432 37.095 @ 1261.31 15.597 @ 1881.1 Pump Data: P1 - Pump Churn Pressure 126.18 P2 - Pump Rated Pressure 109.95 P2 - Pump Rated Flow 1261.31 P3 - Pump Pressure @ Max Flow 79.39 P3 - Pump Max Flow 1881.1 City Residual Flow @ 0 4846.63 City Residual Flow @ 20 3892.74 City Water @ 150% of Pump 49.58 Demand: D1 - Elevation 9.239 D2 - System Flow 187.215 D2 - System Pressure 38.207 Hose ( Demand ) D3 - System Demand 187.215 Hose ( Adj City) 100 Safety Margin 141.300 210 196 Al +1131 182 p 168 R 154 E 140 S 126 S 112 U 98 A3 + P3 R 84 E 70 C1 56 42Al 28 14 A3 D1 200 400 600 800 1000 1200 1400 1600 1800 FLOW N^1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Diagram Wiginton Fire Systems Page 3 2010771 - B1 S1RA2 Date 5-19-17 20.3 D1 *- 1 14.8 D2 2 15.2 D3 r- 3 17.9 D4 *- 4 1 1 47.9 19.4 DS 5 18.9 D6 a 6 1 1 18.9 20.? D7 7 19.8 D8 +- 8 1 19.8 20.a D9 9 20.4 D10+- 10 20.3 1 +- M1 14.8 2 2A 15.2 47.9 3 +.- 2A 4- 4 F 5 M2 30 67.3 18.9 6 +- 7 +- M3 39.1 1 126.7 19.8 1 8 9 M4 1 40.1 1 40.1 126.7 20.1 1 10 +- M4 I I 20.3 1 126.7 187.2 M1 +- M2M3 M4 FL2r BR1+- PO 876 187.2 187.2 187.2 287.2 287.2 PI SP/G- UG&- UG4+- UGSi UG6 TEST 187.2 287.2 287.2 Computer Programs by Hydratec Inc. Revision: 50.52.1 Fitting: :d Summary Wiginton Fire Systems Page 4 2010771 - B1 S1RA2 Date 5-19-17 Fitting Legend Abbrev. Name _ '/2 ' % 1 1'% 1'% 2 2'/: 3 3'/: 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0E90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61GGenericGateValve0000011112 __ 2 3 4 5 6 7 8 10 11 13LLongTurnElbow1122234556891316182427303440SGenericSwingCheckValve4557911141619222732455565768798109130T90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121V90' Ell Firelock #001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0ZafAmes3000SSFittinggeneratesaFixedLossBasedonFlow Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD Wiginton Fire Systems Page 5 2010771 - B1 S1RA2 Date 5-19-17 Node Elevation K -Fact Pt Pn Flow Density Area PressNo. Actual Actual Req_ D1 23.333 5.6 13.08 na 20.25 0.1 56 7.0D223.333 5.6 7.0 na 14.82 0.1 124 7.0D323.333 5.6 7.34 na 15.17 0.1 124 7.0D423.333 5.6 10.27 na 17.95 0.1 126 7.0D523.333 5.6 11.97 na 19.37 0.1 70 7.0D623.333 5.6 11.38 na 18.89 0.1 126 7.0D723.333 5.6 13.07 na 20.25 0.1 56 7.0D823.333 5.6 12.53 na 19.82 0.1 30 7.0D923.333 5.6 13.18 na 20.33 0.1 144 7.0D1023.333 5.6 13.23 na 20.37 0.1 144 7.0124.333 13.05 na 2 24.333 6.79 na 3 24.333 7.14 na 2A 24.333 7.72 na 4 24.333 10.48 na 5 24.333 12.05 na 6 24.333 11.64 na 7 24.333 13.44 na 8 24.333 12.86 na 9 24.333 13.55 na 10 24.333 13.2 na M1 24.333 14.43 na M2 241333 14.43 na M3 24.333 14.51 na M4 24.333 14.87 na FL2 24.333 28.42 na BR1 2.0 38.18 na PO 2.0 38.21 na PI 2.0 53.79 na SPIG 3.0 55.97 na IG3 3.0 56.04 na 100.0 UG4 3.0 61.47 na UG5 3.0 61.66 na UG6 3.0 61.8 na TEST 2.0 59.68 na The maximum velocity is 14.44 and it occurs in the pipe between nodes 5 and M2 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 6 2010771 - B1S1RA2 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn EQUIVALENT K'S D1 20.25 1.049 E 2.0 1.000 13.081 K Factor = 5.60 to 120.0 0.0 2.000 -0.433 1 20.25 0.1333 0.0 3.000 0.400 Vel = 7.52 0.0 20.25 13.048 K Factor= 5.61 D2 14.82 1.049 E 2.0 1.000 7.000 K Factor = 5.60 to 19.37 120.0 0.0 2.000 0.433 K Factor = 5.60 2 14.82 0.0747 0.0 3.000 0.224 Vel = 5.50 5 0.0 0.1226 0.0 4.208 0.516 to 14.82 120.0 0.0 5.000 6.791 K Factor= 5.69 D3 15.17 1.049 E 2.0 1.000 7.338 K Factor = 5.60 to 18.89 120.0 0.0 2.000 0.433 K Factor = 5.60 3 15.17 0.0783 0.0 3.000 0.235 Vel = 5.63 0 15.17 7.140 K Factor =_ 5.6_8_ D4 17.95 1.049 T 5.0 1.000 10.272 K Factor = 5.60 to 120.0 0.0 5.000 0.433 4 _ 17.95 0.1065 0.0 6.000 0.639 Vel = 6.66 6 0.0 17.95 0.1170 0.0 10.478 K Factor = 5.55 D5 19.37 1.049 E 2.0 2.208 11.968 K Factor = 5.60 to 18.89 120.0 0.0 2.000 0.433 K Factor = 5.54 5 19.37 0.1226 0.0 4.208 0.516 to 0.0 120.0 0.0 5.000 0.433 Vel _7.19 7 19.37 0.1332 6.000 12.051 K Factor= 5.58 D6 18.89 1.049 T 5.0 1.000 11.376 K Factor = 5.60 to 20.25 120.0 0.0 5.000 0.433 K Factor= 5.52. 6 18.89 0.1170 0.0 6.000 0.702 Vel = 7.01 19.8_2 0.0 6.000 0.0 Vel -=- 7.36 19.82 12.862 18.89 20.33 1.049 13.176 11.645 K Factor = 5.54 D7 20.25 1.049 T 5.0 1.000 13.074 K Factor = 5.60 to 120.0 0.0 5.000 0.433 13.231 7 20.25 0.1332 0.0 6.000 0.799 Vel = 7.52 0.404 0.0 20.25 13.440 K Factor= 5.52. D8 19.82 1.049 to 0.0120.0 8 19.8_2 0.1280 6.000 0.0 Vel -=- 7.36 19.82 12.862 D9 20.33 1.049 e D10 to 10 120.0 T T 20.33 0.1342 0.0 20.33 20.37 1.049 E 120.0 20.37 0.1347 5.0 1.000 12.527 K Factor = 5.60 0.0 5.000 0.433 0.0_ _ 6.000 0.768 Vel -=- 7.36 12.862 K Factor = 5.53 5.0 1.000 13.176 K Factor = 5.60 0.0 5.000 0.433 0.0 6.000 0.805 Vel = 7.55 13.548 K Factor= 5.52 2.0 1.000 13.231 K Factor = 5.60 0.0 2.000 0.433 0.0 3.000 0.404 Vel = 7.56 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 7 2010771 - B1S1RA2 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv •"•"` Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 20.37 13.202 K Factor= 5.61 1 20.25 1.049 T ' 5.0 5.375 13.048 to 120.0 0.0 5.000 0.0 M1 20.25 0.1332 0.0 10.375 1.382 Vel = 7.52 0.0 20.25 14.430 K Factor= 5.33 2 14.82 1.049 T 5.0 7.500 6.791 19.82 to 9 120.0 1.38 0.0 5.000 0.0 M4 2A 14.82 0.0747 0.0 0.0 12.500 0.934 Vel = 5.50 10 0.0 1.049 to 120.0 M4 20.37 0.1346 14.82 7.725 K Factor = 5.33__ 3 15.17 1.049 T 5.0 2.500 7.140 to ,'' 120.0;' 0.0 -;'' 5.000 0.0 -- ;'' 1V ' 2A 15.17_ 0.0780 0.0 _ _ 7.500 0.585_ V_el = 2A 14.82 1.049 0.0 10.000 7.725 5_.6.3 to 120.0 0.0 0.0 0.0 4 29.99 0.2753 0.0 10.000 2.753 Vel = 11_.13 4 17.94 1.38 0.0 9.125 10.478 to 120.0 0.0 0.0 0.0 5 --- 47.93 0.1724 0.0 9.125 1.573 Vel = 10.28 5 19.38 1.38 T 6.0 1.375 12.051 to 120.0 0.0 6.000 0.0 M2 _ _ 67.31 0.3231 0.0 - 7.375 2.383 Vel =_14.44 0.0 67.31 14.434 K Factor= 17.72 6 18.89 1.049 2E 4.0 11.333 11.645 to 120.0 0.0 4.000 0.0 7 18.89 0.1171 0.0 15.333 1.795 Vel = 7.01 7 20.25 1.38 T 6.0 3.000 13.440 to 120.0 0.0 6.000 0.0 M3 39.14 0.1184 0.0 9.000 1.066 Vel = 8.40 0.0 39.14 14.506 K Factor= 10.28 8 19.82 1.38 to 9.000120.0 9 19.82 0.0337_ 9 20.33 1.38 to 6.000120.0 M4 40.15 0.1242 0.0 40.15 10 20.37 1.049 to 120.0 M4 20.37 0.1346 0.0 E 3.0 11.375 12.862 T 6.0 9.000 0.0 0.0 _____20.375 0.68_6 T 6.0 4.625 13.548 0.0 6.000 0.0 0.0 10.625 1.320 14.868 T 5.0 7.375 13.202 0.0 5.000 0.0 0.0 12.375 1.666 Computer Programs by Hydratec Inc. Revision: 50.52.1 Vel = 4.25 Vet = 8.61 K Factor= 10.41 Vel = 7.56 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 8 2010771 - B1 S1 RA2 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv •"•"` Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 20.37 - _- __14.868 _ K Factor= 5.28 M1 20.25 2.703 0.0 3.375 14.430 to 120.0 to 12.845 120.0 0.0 0.0 0.0 BR1 187.22 0.0012 M2 20.25 0.0012 0.0 3.375 0.004 Vel = 1.13 M2 67.31 2.703 0.0 3.625 14.434 50.044 63.389 to 120.0 0.0 0.0 0.0 67.889 0.024 M3 87.56 0.0199 0.0 3.625 0.072 Vel = 4.90 M3 39.14 2.703 0.0 9.167 14.506 Factor= 30_._29_ System Demand Pressure to 120.0 0.0 0.0 0.0 Safety Margin M4 126.7 0.0395 0.0 9.167 0.362 Vel = 7.08 M4 60.52 2.703 6V 40.099 108.208 14.868 to 120.0 T 18.651 58.750 0.0 125.720 FL2 187.22 0.0812 0.0 166.958 13.552 Vel = 10.47 PI 0.0 8.249 T 38.923 2.500 53.787 187.22 28.420 K Factor= 35.12 _ FL2 187.22 6.385 T 38.536 22.333 28.420 to 120.0 B 12.845 51.381 9.672 BR1 187.22 0.0012 0.0 -_ 73.714 0.091_ Vel = 1.88 BRI 0.0 8.249 B 13.345 4.500 38.183 to 120.0 S 50.044 63.389 0.0 PO 187.22 0.0004 0.0 67.889 0.024 Vel = 1.12 0.0 187.22 - - 38.207 _ Factor= 30_._29_ System Demand Pressure 38.207 K_ Safety Margin 141.300 Continuation Pressure 179.507 Pressure @ Pump Outlet 179.507 Pressure From Pump Curve 125.720 Pressure @ Pump Inlet 53.787 PI 0.0 8.249 T 38.923 2.500 53.787 to 120.0 G 4.448 43.371 2.166 SPIG 187.22 0.0003 0.0 45.871 0.015 Vel = 1.12 SPIG 0.0 8.27 E 26.955 195.000 55.968 to 140.0 T 52.413 85.358 0.0 UG3 187.22 0.0003 G 5.99 280.358 0.074 Vel = 1.12 UG3 99.99 8.27 T 52.413 300.000 56.042 Qa = 100 to 140.0 Zaf 0.0 130.283 5.179 Fixed Loss = 5.179 UG4 2.8_7.21 0.000_ _6_ 4L 77.87 430.28_3 0.250 Vel = 1.72 UG4 0.0 10.28 T 71.092 865.000 61.471 to 140.0 0.0 71.092 0.0 UG5 287.21 0.0002 0.0 936.092 0.189 Vel = 1.11 UG5 0.0 12.34 T 88.164 1600.000 61.660 to 140.0 0.0 88.164 0.0 UG6 _ 2.87.21 0.0001_ - 0.0 1688.164 0.139 Vel = 0.77 UG6 0.0 12.34 T 88.164 450.000 61.799 to 140.0 0.0 88.164 2.166 TEST 287.21 0.0001 0.0 538.164 0.045 Vel = 0.77 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 9 2010771 - B1S1RA2 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 287.21 59.678 K Factor= 37.1 d ,:0 d ,, Computer Programs by Hydratec Inc. Revision: 50.52.1 ogan:Dm FIRE SYSTEMS Wiginton Fire Systems 699 Aero Lane Sanford, FL 32771 407-585-3200 Job Name 2010771 - B1S2RA1 Drawing FP4/FP5 Location BUILDING ONE Remote Area B1S2RA1 Contract 2010771 Data File 2010771 - B1S2RA1.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 M Wiginton Fire Systems 2010771 - B1S2RA1 Page 1 Date 5-19-17 Project name: GANESH NORTH Location: BUILDING ONE Drawing no: FP4/FP5 Date: 5-19-17 Design HYDRAULIC CALCULATIONS for Remote area number. B1S2RA1 Remote area location: SYSTEM TWO Occupancy classification: HIGH PILED STORAGE Density: 52 PSI - Gpm/SgFt Area of application: 12 HEADS - SgFt Coverage per sprinkler. 100 MAX - SgFt Type of sprinklers calculated. 16.81K ESFR PENDENT No. of sprinklers calculated. 12 In -rack demand. N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 1709.928 - GPM Type of system: WET Volume of dry or preaction system: N/A - Gal Water supply information Date: 8-2-16 Location: ALONG W. 1ST STREET Source: WFS Name of contractor. WIGINTON FIRE SYSTEMS Address: 699 AERO LANE, SANFORD, FL 32771 Phone number: 407-585-3200 Name of designer. W. AMMONS Authority having jurisdiction: CITY OF SANFORD Notes: (Include peaking information or gridded systems here.) @ 39.124 -Psi Computer Programs by Hydratec Inc. Revision: 50.52.1 Water ply Curare C Wiginton Fire Systems Page 22010771 - B1S2RA1 Date 5-19-17 City Water Supply: C1 - Static Pressure : 60 C2 - Residual Pressure: 50 C2 - Residual Flow : 1840 City Water Adjusted to Pump for Pf - Elev - Hose Flow Inlet Al - Adjusted Static: A2 - Adj Resid A3 - Adj Resid 54.436 - 33.185 @ 1261.31 10.52 @ 1881.1 Pump Data: P1 - Pump Churn Pressure 126.18 P2 - Pump Rated Pressure 109.95 P2 - Pump Rated Flow 1261.31 P3 - Pump Pressure @ Max Flow 79.39 P3 - Pump Max Flow 1881.1 City Residual Flow @ 0 4846.63 City Residual Flow @ 20 3892.74 City Water @ 150% of Pump 49.58 Demand: D1 - Elevation 14.738 D2 - System Flow 1459.93 D2 - System Pressure 117.356 Hose ( Demand ) D3 - System Demand 1459.93 Hose ( Adj City) 250 Safety Margin 12.144 210 196 Al +1121 182 p 168 R 154 A2+P2 E 140 S 126 = S 112 U 98 R 84 E 70 C1 56 42 Al 28 14 D1 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N^1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow D IM Wiginton Fire Systems 2010771 - B1S2RA1 Page 3 Date 5-19-17 121.3 242.7 465.6 729.9 731.3 7383 757.6 796.8 864.4 989,7 1169.4 H3 <-H4 F100F101F103 105f107F 109F111(--113i-115F 117+-119(-121F123F 125+- 127 129f131+-133F135 137 141 242.7 242.7 729.2 730.2 733.7 746 774.2 826.5 911.7 1039.5 1310.2 149.7 1459.9 139 e- 141 TR2+- BR2+- PO 1459.9 1459.9 1459.9 1709.9 1709.9 PI SPIG- UG3(- UG4+- UG5*- UG6 UG7 TEST 1459.9 1709.9 0.2 243.2 243.2 730.7 729.7 726.2 713.9 685.7 633.4 548.2 420.5 149.7 149.7H3 - H2 a H1 200 +- 201 203 F 205 +- 207 *- 209 a 211 F 213 +- 215 t 217 219 +- 221 +- 223 - 225 t 227 a- 229 F- 231 i- 233 i- 235 237 +- 239 +- 238 *- 138 +- 139121.2 243.2 486.6 730 7287 721.6 702.3 663.1 595.5 = 490.3 290.5 149.7 149.7 243.4 121.3 121.4 242.9 203 - 202 - H5 -+ H6 +- H7 F H8 a 102 f 103 t 243.4 0.2 242.9 T 1 486.6 1 485.6 1 244.1 121.7 121.8 2446 205 - 204 - H9 -r H10*-- HI i- H12+- 104 F 105 t 244.1 02 243.6 1 730.7 1 06 0.6 207 206 r- 106 F 107 T 0.6 T 1 730 1 729.9 1 0.4 0.41 209 208 108+- 109 T 0.4 T 1 729.7 1 730.2 I 1 1 I 211-210-110<- 111 T t T 1 728.7 1 731.3 1 2.4 2.41 213e 212- 112+- 113 T 2.4 T 1 726.2 1 733.7 1 4.6 4,61 2151 214+- 114E 115 T 4.6 T 1 721.6 1 738.3 1 7.7 7.71 217 216 116 i- 117 T 7.7 T 1 713.9 1 746 1 11.6 11.6 219 r- 218 r- 118(.- 119 T 11.6 T 1 702.3 1 757.6 1 16.6 16.6 221 f.. 220 120 +- 121 T 16.6 T 1 685.7 1 774.2 1 22.6 22.6 223 f 222 f- 122 (- 123 T 22.6 T 1 663.1 1 796.8 Computer. Programs by Hydratec Inc. Revision: 50.52.1 Flow [ am Wiginton Fire Systems 2010771 - B1S2RA1 Page 4 Date 5-19-17 1 29.7 29.1 225 t- 224 i- 124 r- 125 T 29.7 t 1 633.4 1 826.5 1 37.9 37.¢ 227 226 <- 126 r- 127 T 37.9 t 1 595.5 1 864.4 1 47.3 47.8 229*- 228 . 128 129 T 47.3 t 1 548.2 1 911.7 1 57.9 57.¢ 231 a 230 +- 130 +- 131 T 57.9 t 1 490.3 1 969.7 1 69.8 69.8 233 232 +- 132 i- 133 1 69.8 t 1 420.5 1 1039.5 1 130 13Q 235 +- 234 +- 134 F 135 T 130 t 1 290.5 1 1169.4 1 140.7 14%7 237 < 236 e- 136 f- 137 140.7 Computer Programs by Hydratec Inc. Revision: 50.52.1 Fitting: d Summary Wiginton Fire Systems Page 5 2010771 - B1S2RA1 Date 5-19-17 Fitting Legend Abbrev. Name '/: '/. 1 1'/. 1'/: 2 _ 2%: 3 3%z 4 _5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 __ 9 10 12 19 21 0 0 0 0 0 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61GGenericGateValve00000111122345678101113LLongTumElbow1122234556891316182427303440SGenericSwingCheckValve4557911141619222732455565768798109130T90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90' Ell Firelock #001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0X90'Tee-BranchFirelock002 0 ' 0 0 0 0 8.5 10.8 13 0 16 21 25 33 0 0 0 0 0 0 0 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD Wiginton Fire Systems Page 6 2010771 - B1S2RA1 Date 5-19-17 Node Elevation K -Fact Pt Pn Flow Density Area Press No.Actual Rte'-- - --- H3 36.03 16.8 52.0 na 121.15 0.1 100 52.0 H4 36.38 16.8 52.21 na 121.39 0.1 100 52.0 100 32.42 67.31 na 101 29.72 71.28 na 103 29.72 71.4 na 105 29.72 71.8 na 107 29.72 72.67 na 109 29.72 73.54 na 111 29.72 74.41 na 113 29.72 75.29 na 115 29.72 76.16 na 117 29.72 77.05 na 119 29.72 77.96 na 121 29.72 78.89 na 123 29.72 79.86 na 125 29.72 80.88 na 127 29.72 81.98 na 129 29.72 83.17 na 131 29.72 84.48 na 133 29.72 85.95 na 135 29.02 95.06 na 137 29.02 97.14 na 939 29.02 X1198.88 na 141 29.02 98.91 na TR2 29.02 99.66 na BR2 2.0 115.69 na PO 2.0 117.36 na PI 2.0 26.46 na SPIG -3.0 29.35 na UG3 -3.0 32.65 na 250.0 1G4 -3.0 43.32 na UG5 -3.0 48.44 na UG6 -3.0 52.23 na TEST 2.0 51.27 na H2 35.62 16.8 52.18 na 121.35 0.1 100 52.0 Hl 35.2 16.8 52.72 na 121.98 0.1 100 52.0 200 32.09 67.44 na 201 29.38 71.42 na 203 29.38 71.54 na 205 29.38 71.95 na 207 29.38 72.82 na 209 29.38 73.69 na 211 29.38 74.56 na 213 29.38 75.43 na 215 29.38 76.29 na 217 29.38 77.14 na 219 29.38 77.97 na 221 29.38 78.78 na 223 29.38 79.56 na 225 29.38 80.29 na 227 29.38 80.96 na 229 29.38 81.55 na 231 29.38 82.06 na 233 29.38 82.48 na 235 29.38 82.8 na 237 29.38 82.95 na 239 29.38 83.0 na 238 32.09 82.97 na 138 31.73 96.56 na 202 32.09 67.55 na H5 35.2 16.8 52.81 na 122.09 0.1 100 52.0 H6 35.62 16.8 52.26 na 121.45 0.1 100 52.0 Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - Standard Wiginton Fire Systems Page 7 2010771 - B1S2RA1 Date 5-19-17 Node Elevation K -Fact Pt Pn Flow Density Area Press No. Actual-- Actual Req: -- H7 36.03 16.8 52.09 na 121.25 0.1 100 52.0 H8 36.38 16.8 52.3 na 121.5 0.1 100 52.0 102 32.42 67.42 na 204 32.09 67.94 na H9 35.2 16.8 53.13 na 122.46 0.1 100 52.0 H10 35.62 16.8 52.58 na 121.82 0.1 100 52.0 H11 36.03 16.8 52.4 na 121.62 0.1 100 52.0 H12 36.38 16.8 52.62 na 121.87 0.1 100 52.0 104 32.42 67.81 na 206 32.09 71.65 na 106 32.42 71.5 na 208 32.09 72.52 na 108 32.42 72.37 na 210 32.09 73.39 na 110 32.42 73.24 na 212 32.09 74.25 na 112 32.42 74.12 na 214 32.09 75.11 na 114 32.42 74.99 na 216 32.09 75.97 na 116 32.42 75.88 na 218 32.09 76.81 na 118 32:42 76.78 na-11 220 32.09 77.63 na 120 32.42 77.7 na 222 32.09 78.42 na 122 32.42 78.66 na 224 32.09 79.17 na 124 32.42 79.66 na 226 32.09 79.87 na 26 32.42 80.72 na 228 32.09 80.52 na 128 32.42 81.86 na 230 32.09 81.09 na 130 32.42 83.11 na 232 32.09 81.59 na 132 32.42 84.5 na 234 32.09 82.5 na 134 31.73 93.0 na 236 32.09 82.8 na 136 31.73 94.94 na The maximum velocity is 25.79 and it occurs in the pipe between nodes 135 and 137 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 8 2010771 - B1S2RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv *'*'•'• Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn EQUIVALENT K'S REMOTE HEAD TO SUPPLY H3 121.31 2.703 0.0 10.000 52.000 K Factor = 16.80 to 120.0 0.0 0.0 0.152 H4 121.31 0.0364 0.0 10.000 0.364 Vel = 6.78 H4 121.39 2.703 X 16.786 85.210 52.212 K Factor = 16.80 to 120.0 0.0 16.786 1.715 100 242.7 0.1312 0.0 101.996 13.383 Vel = 13.57 100 0.0 2.703 T 18.651 2.710 67.310 to 120.0 0.0 18.651 1.169 101 242.7 0.1312 0.0 21.361 2.803 Vel = 13.57 101 0.0 4.304 0.0 8.330 71.282 to 120.0 0.0 0.0 0.0 103 242.7 0.0136 0.0 8.330 0.113 Vel = 5.35 103 242.91 114.304 0.0 8.330 71:1395 to 120.0 0.0 0.0 0.0 105 _- 485.61 0.0491 0_0 _____8.330 0.409 Vel = 10.71 105 243.64 4.304 0.0 8.330 71.804 to 120.0 0.0 0.0 0.0 107 729.25 0.1043 0.0 _ 8.330 0.869 _ 16.08_- 107 0.63 4.304 0.0 8.330 72.673 Vel to 120.0 0.0 0.0 0.0 109 729.88 0.1043 _ 0.0 8.330 0.869 16.10 109 0.37 4.304 0.0 8.330 73.542 Vel .=. to 120.0 0.0 0.0 0.0 111 730.25 0.1046 0.0 _ 8.330 0.871 _ -__ Vel = 16.10_ 111 1.03 4.304 0.0 8.330 74.413 to 120.0 0.0 0.0 0.0 113 731.28 0.1048 0.0 8.330 0.873 Vel = 16.13 113 2.43 4.304 0.0 8.330 75.286 to 120.0 0.0 0.0 0.0 115 733.71 0.1054 0.0 8.330 0.878 Vel = 16.18 115 4.62 4.304 0.0 8.330 76.164 to 120.0 • 0.0 0.0 0.0 117 738.33 0.1066 0.0 8.330 0.888 Vel = 16.28 117 7.66 4.304 0.0 8.330 77.052 to 120.0 0.0 0.0 0.0 119 745.99 0.1088 0.0 8.330 0.906 Vel = 16.45 119 11.63 4.304 0.0 8.330 77.958 to 120.0 0.0 0.0 0.0 121 757.62 0.1118_ 0.0 8.330---- 0.931 Vel = 16.71 121 16.59 4.304 0.0 8.330 78.889 to 120.0 0.0 0.0 0.0 123 774.21 0.1164 0.0 8.330 0.970 Vel = 17.07 123 22.59 4.304 0.0 8.330 79.859 to 120.0 0.0 0.0 0.0 125 796.8 0.1228 0.0 8.330 1.023 Vel = 17.57 125 29.68 4.304 0.0 8.330 80.882 to 120.0 0.0 0.0 0.0 127 826.48 0.1315 0.0 8.330 1.095 Vel = 18.23 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems 129.500 Page 9 2010771 - B1S2RA1 103.042 Pressure Rump Inlet Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt 26.458- 26.458 Ref. G C" or 2.166 Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn to 140.0 127 37.91 4.304 0.0 0.0 8.330 81.977 280.358 to UG3 250.00 8.27 120.0 52.413 0.0 0.0 0.0 Zaf 129 864.39 0.1427 UG4 1709.93 0.0158 0.0 8.330 1.189 Vel = 19.06 129 47.32 4.304 0.0 8.330 83.166 to 120.0 0.0 0.0 0.0 131 911.71 0.1575 0.0 8.330 1.312 Vel = 20.10 131 57.94 4.304 0.0 8.330 84.478 to 120.0 0.0 0.0 0.0 133 969.65 0.1766 0.0 8.330 1.471 Vel = 21.38 133 69.81 4.304 2V 18.826 25.010 85.949 to 120.0 0.0 18.826 0.303 135 1039.46 0.2008 0.0 - 43.836 8.803 Vel =_22.92 135 129.97 4.304 0.0 8.330 95.055 to 120.0 0.0 0.0 0.0 137 1169.43 0.2498 0_0 J ,, 8.330 2.081 Vel = 25.79 137 140.75 6.385 X 32.113 7.250 97.136 to 120.0 0.0 32.113 0.0 141 1310.18_ 0.0451 0.0 39.363 1.776 Vel = 13.13 0.0 1310.18 98.912 K Factor = 131.74 139 149.74 6.385 X 32.113 1.083 98.885 to 120.0 0.0 32.113 0.0 141 149.74 0.0008 0.0 33.196 0.027 Vel = 1.50 141 1310.19 6.385 V 12.845 0.792 98.912 to 120.0 0.0 12.845 0.0 TR2 _ 1459.93 0.0551 0.0 13.637 0.752 14.63 TR2 0.0 6.385 T 38.536 27.020 99.664 Vel to 120.0 B 12.845 51.381 11.702 BR2 1459.93 0.0552 0.0 78.401 4.325 Vel = 14.63 BR2 0.0 8.249 2V 28.914 12.833 115.691 to 120.0 B 13.345 92.303 0.0 PO 1459.93 0.0158 S 50.044 105.136 1.665 Vel = 8.76 _ 0.0 1459.93 117.356 K Factor = 134.77 System Demand Pressure 117.356 Safety Margin 12.144 Continuation Pressure 129.500 Pressure @ Pump Outlet 129.500 Pressure From Pump Curve 103.042 Pressure Rump Inlet PI 0.0 8.249 T 38.923 2.500 26.458- 26.458 to 120.0 G 4.448 43.371 2.166 SPIG 1459.93 0.0158 0.0 45.871 0.726 SPIG 0.0 8.27 E 26.955 195.000 29.350 to 140.0 T 52.413 85.358 0.0 UG3 1459.93 0.0118 G 5.99 280.358 3.298 UG3 250.00 8.27 T 52.413 300.000 32.648 to 140.0 Zaf 0.0 130.283 3.893 UG4 1709.93 0.0158 4L 77.87 430.283 6.782 Computer Programs by Hydratec Inc. Revision: 50.52.1 Vel = 8.76 Vel = 8.72 Qa = 250 Fixed Loss = 3.893 Vel = 10.21 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 10 2010771 - B1S2RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ••""' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UG4 0.0 10.28 T 71.092 865.000 43.323 to to 140.0 0.0 71.092 0.0 UG5 1709.93 0.0055 0.0 936.092 5.113 Vel = 6.61 UG5 0.0 12.34 T 88.164 1600.000 48.436 to 0.37 140.0 0.0 88.164 0.0 UG6 1709.93 0.0022 0.0 1688.164 3.790 Vel = 4.59 UG6 0.0 12.34 T 88.164 450.000 52.226 to to 140.0 0.0 88.164 2.166 0.0 TEST 1709.93 0.0022 0.0 538.164 1.208 Vel = 4.59 0.870 0.0 16.10 209 0.37 4.304 0.0 8.330 1709.93 to 51.268 K Factor = 238.81 NEW PATH 0.0 0.0 211 H3 0.16 2.703 0.0 10.000 52.000 16_.0_9___ to 1.03 120.0 0.0 0.0 0.178 H2 _ ; 0.16_ 0.0 I'd 0.0 _ 10:000 0.0 ; Vel = 0.01,_a H2 121.35 2.703 0.0 10.000 52.178 K Factor = 16.80 to Vel = 120.0 0.0 0.0 0.182 0.0 H1 _ 121.19 0.0362 0.0 _ 10.000 _ 0.362 _ _ Vel _ 6.78 H1 121.99 2.703 X 16.786 84.730 52.722 K Factor = 16.80 to 0.0 120.0 0.0 16.786 1.347 215 200 243.18 0.1317 0.0 _ 101.516 13.368 Vel = 13.60 200 0.0 2.703 T 18.651 2.710 67.437 i to 217 120.0 0.0 18.651 1.174 0.852 201 _ 243.18 _ 0.1316 0.0_ 21.361 ____.__._2.812 Vel = 1.3.60_ 201 0.0 4.304 0.0 8.330 71.423 to 120.0 0.0 0.0 0.0 203 243.18 0.0137 0.0 8.330 0.114 Vel = 5.36 203 243.38 4.304 0.0 8.330 71.537 to 120.0 0.0 0.0 0.0 205 486.56 0.0493 0.0 8.330 0.411 Vel = 10.73 205 244.12 4.304 0.0 8.330 71.948 to 120.0 0.0 0.0 0.0 207 730.68 0.1046 0.0 8.330 0.871 Vel = 16.11 207 0.63 4.304 0.0 8.330 72.819 to 120.0 0.0 0.0 0.0 209 730.05 0.1044 0.0 8.330 0.870 Vel = 16.10 209 0.37 4.304 0.0 8.330 73.689 to 120.0 0.0 0.0 0.0 211 729.68 0.1044 0.0 8.330 0.870 Vel = 16_.0_9___ 211 1.03 4.304 0.0 8.330 74.559 to 120.0 0.0 0.0 0.0 213 728.65 0.1041 0.0 8.330 0.867 Vel = 16.07 213 2.43 4.304 0.0 8.330 75.426 to 120.0 0.0 0.0 0.0 215 726.22 0.1034 0.0 8.330 0.861 Vel = 16.01 215 4.62 4.304 0.0 8.330 76.287 to 120.0 0.0 0.0 0.0 217 721.6 0.1023 0.0 8.330 0.852 Vel = 15.91 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 11 2010771 - B1S2RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes ""•• Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 217 7.66 4.304 0.0 8.330 77.139 - --- to 1.174 120.0 0.0 0.0 0.0 1.146 Vel = 8.37 0.0 219 713.94 0.1002 0.0 8.330 0.835 Vel = 15.74 219 11.64 4.304 0.0 8.330 77.974 203 -243.38 2.703 to 2.710 120.0 0.0 0.0 0.0 18.651 1.174 221 702.3 0.0971 0.0 8.330 0.809 Vel = 15.49 221 16.58 4.304 0.0 8.330 78.783 to 120.0 0.0 0.0 0.0 223 685.72 0.0930 0.0 8.330 0.775 Vel = 15.12 223 22.59 4.304 0.0 8.330 79.558 to 120.0 0.0 0.0 0.0 225 663.13 0.0874 0.0 8.330 0.728 Vel = 14.62 225 29.69 4.304 0.0 8.330 80.286 to 120.0 0.0 0.0 0.0 227 633.44 0.0804 0.0 8.330 0.670;;____ Vel = 13.97 227 37.91 4.304 0.0 8.330 80.956 f to 120.0 0.0 0.0 0.0 229 595.53 0.0717 0.0 8.330 0.597 Vel = 13.13 229 47.31 4.304 0.0 8.330 81.553 to 120.0 0.0 0.0 0.0 231 548.22 0.0615 0.0 8.330 0.512 Vel = 12.09 231 57.94 4.304 0.0 8.330 82.065 to 120.0 0.0 0.0 0.0 233 490.28 0.0499 0.0 8.330 0.416 Vel = 10.81 233 69.82 4.304 0.0 8.330 82.481 to 120.0 0.0 0.0 0.0 235 420.46 0.0377 0.0 8.330 0.314 Vel = 9.2.7_ 235 129.97 4.304 0.0 8.330 82.795 to 120.0 0.0 0.0 0.0 237 290.49 0.0190 0.0 8.330 0.158 Vel = 6.41 237 140.75 4.304 0.0 8.330 82.953 to 120.0 0.0 0.0 0.0 239 149.74 0.0055 0.0 8.330 0.046 Vel = 3.30 239 0.0 2.703 T 18.651 2.710 82.999 to 120.0 0.0 18.651 1.174 238 149.74 0.0537 0.0 21.361 1.148 Vel = 8.37 238 0.0 2.703 2X 33.571 216.640 82.973 to 120.0 0.0 33.571 0.156 138 149.74 0.0537 0.0 250.211 13.436 Vel = 8.37 138 0.0 2.703 T 18.651 2.710 96.565 to 120.0 0.0 18.651 1.174 139 1.49.74 0.0536 0.0 21.361 1.146 Vel = 8.37 0.0 149.74 98.885 K Factor= 15.06 NEW PATH 203 -243.38 2.703 T 18.651 2.710 71.537 to 120.0 0.0 18.651 1.174 202 -243.38 0.1319 0.0 21.361 2.817 Vel = 13.61 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 12 2010771 - B1S2RA1 Date 5-19-17 Hyd. Oa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 202 0.0 2.703 X 16.786 84.730 67.546 to 120.0 0.0 16.786 -1.347 H5 -243.38 -0.1319 0.0 101.516 -13.388 Vel = 13.61 H5 122.09 2.703 0.0 10.000 52.811 K Factor = 16.80 to 120.0 0.0 0.0 -0.182 H6 -121.29 -0.0364 0.0 10.000 -0.364 Vel = 6.78 H6 121.45 2.703 0.0 0.0 10.000 52.265 K Factor = 16.80 to 120.0 120.0 0.0 0.0 0.0 0.178 121.67 H7 0.16 0.0001 0.366 0.0 10.000 0.001 Vel = 0.01 H7 121.25 2.703 K Factor = 16.80 0.0 10.000 52.088 K Factor = 16.80 to 0.178 120.0 H11 0.0 0.0 0.152 10.000 H8 121.41 0.0364 243.64 0.0 10.000 0.364 Vel = 6.79 H8 121.50 2.703 X 16.786 85.210 52.300 K Factor = 16.80 to 243.64 120.0 0.0 16.786 1.715 NEW PATH 102 ;,, 242.91 0.1314._:,) 0.0 101.996 T 13.404 , Vel = 13.58.;, T 102 0.0 2.703 T 18.651 2.710 67.419 0.0 to 1.174 120.0 206 0.0 18.651 1.169 21.361 103 242.91 0.1314 0.0 21.361 ------- 2.807 _ - Vel = 13.58 0.0 242.91 71_._395 _ K Facto_ r = 28.75 NEW PATH 205 244.12 2.703 T 18.651 2.710 71.948 to 120.0 0.0 18.651 1.174 204 244.12 0.1326 0.0 21.361 ----- 2.833--- _ Vel = 13.65 204 0.00.0 2.703 X 16.786 84.730 67.941 to 120.0 0.0 16.786 1.347 H9 244.12 0.1326 0.0 101.516 13.464 Vel = 13.65 H9 122.45 2.703 0.0 10.000 53.130 K Factor = 16.80 to 121.87 120.0 0.0 0.0 0.182 K Factor = 16.80 H10 121.67 0.0366 0.0 10.000 0.366 Vel = 6.80 H10 121.82 2.703 0.0 10.000 52.582 K Factor = 16.80 to 0.0 120.0 0.0 0.0 0.178 H11 0.15 0.0001 0.0 10.000 0.001 Vel = 0.01 H11 to H12 121.62 121.77 . 2.703 120.0 0.0367 0.0 0.0 0.0 10.000 0.0 10.000 52.405 0.152 0.367 K Factor = 16.80 Vel = 6.81 H12 121.87 2.703 X 16.786 85.210 52.620 K Factor = 16.80 to 120.0 0.0 16.786 1.715 104 243.64 0.1321 0.0 101.996 13.477 Vel = 13.62 104 0.0 2.703 T 18.651- 2.710 67.812 - to 120.0 0.0 18.651 1.169 105 243.64 0.1322 0.0 21.361 2.823 Vel = 13.62 0.0 243.64 71.804 K Factor= 28.75 NEW PATH 207 0.63 2.703 T 18.651 2.710 72.819 0 120.0 0.0 18.651 1.174 206 0.63 0.0 0.0 21.361 0.001 Vel = 0.04 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 13 2010771 - B1S2RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """` Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 206 0.0 2.703 2X 33.571 199.970 71.646 to to 120.0 0.0 33.571 0.143 106 0.63 0.0 0.0 233.541 0.0 Vel = 0.04 106 0.0 2.703 T 18.651 2.710 71.503 to 199.970 120.0 0.0 18.651 1.169 107 0.63 0.0 0.0 21.361 0.001 Vel = 0.04 0.0 0.63 72.673 K Factor= 0.07 NEW PATH 209 0.37 2.703 T 18.651 2.710 73.689 to 211 120.0 0.0 18.651 1.174 2.710 208 0.37 0.0 0.0 21.361 0.001 Vel = 0.02 208 0.0 2.703 2X 33.571 199.970 72.516 to 21.361 120.0 0.0 33.571 0.143 2.703 108 0.37 0.0 _ 0.0 _ 233.54,1"il 0.0 1, Vel = 0.02_ 108 0.0 2.703 T 18.651 2.710 72.373 110 to 0.0 120.0 0.0 18.651 1.169 Vel = 0.06 109 -__ 0.37 0.0 0.0 21.361 0.0 _ Vel = 0.0 120.0 0.0 18.651 1.169 0.37 111 1.03 0.0 73.542 K Factor= 0 04 NEW PATH 211 1.03 2.703 T 18.651 2.710 74.559 to 120.0 0.0 18.651 1.174 210 -_ 1.03 0.0 __- 0.0_ 21.361 0.0 _ Vel = 0.0_6_ 210 0.0 2.703 2X 33.571 199.970 73.385 to 120.0 0.0 33.571 0.143 110 1.03 0.0 0.0 233.541 0.001 Vel = 0.06 110 0.0 2.703 T 18.651 2.710 73.243 to 120.0 0.0 18.651 1.169 111 1.03 0.0 0.0 21.361 0.001 Vel = 0.06 0.0 1.03 74.413 K Factor= 0.12 NEW PATH 213 2.43 2.703 T 18.651 2.710 75.426 to 120.0 0.0 18.651 1.174 212 2.43 0.0 • 0.0 21.361 0.0 • Vel = 0.14 212 0.0 2.703 2X 33.571 199.970 74.252 to 120.0 0.0 33.571 0.143 112 2.43_ 0.00.0 233.541_ 0.007 - Vel = 0.14 112 0.0 2.703 T 18.651 2.710 74.116 to 120.0 0.0 18.651 1.169 113 2.43 0.0 0.0 21.361 0.001 Vel = 0.14 0.0 2.43 75.286 K Factor = 0.28 NEW_ PATH__ 215 4.62 2.703 T 18.651 2.710 76.287 _--- to 120.0 0.0 18.651 1.174 214 4.62 0.0001 0.0 21.361 0.002 Vel = 0.26 Computer Programs by Hydratec Inc. Revision: 50.52.1 C Final Calculations - Hazen -Williams Wiginton Fire Systems Page 14 2010771 - B1S2RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes "*"* Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 214 0.0 2.703 2X 33.571 199.970 75.115 to 120.0 0.0 33.571 0.143 114 4.62 0.0001 0.0 233.541 0.020 Vel = 0.26 114 0.0 2.703 T 18.651 2.710 74.992 to 120.0 0.0 18.651 1.169 115 4.62 0.0001 0.0 21.361 0.003 Vel = 0.26 0.0 4.62 76.164 K Factor = 0.53 NEW PATH 217 7.66 2.703 T 18.651 2.710 77.139 to 120.0 0.0 18.651 1.174 216 7.66 0.0002 0.0 21.361 0.005 Vel = 0.43 216 0.0 2.703 2X 33.571 199.970 75.970 to 120.0 0.0 33.571 0.143 116 Z66 0.0002 _ 0.0 233.541 0.051 -_ Vel = 0.4.3_- 116 0.0 2.703 T 18.651 2.710 75.878 to 120.0 0.0 18.651 1.169 117 7.66 0.0002_ _ 0.0 21.361 _ 0.005 _ Vel = 0.43 0.0 7.66 77.052 K Factor = 0.87 NEW PATH 219 11.63 2.703 T 18.651 2.710 77.974 to 120.0 0.0 18.651 1.174 218 11.63 0.0005 0.021.361 0.010 _ Vel = 218 0.0 2.703 2X 33.571 199.970 76.810 to 120.0 0.0 33.571 0.143 118 11.63 0.0005. 0.0 233.541 0.111 Vel = 0.65 118 0.0 2.703 T 18.651 2.710 76.778 to 120.0 0.0 18.651 1.169 119 11.63 0.0005 0.0 21.361 0.011 Vel = 0.65 0.0 11.63 77.958 K Factor = 1.32 NEW PATH 221 16.59 2.703 T 18.651 2.710 78.783 to 120.0 0.0 18.651 1.174 220 16.59 0.0009 0.0 21.361 0.020 Vel = 0.93 220 0.0 2.703 2X 33.571 199.970 77.629 to 120.0 0.0 33.571 0.143 120 --_ 16_59 _ 0.0009 - -- 0.0 233.541 2.710 0.214 Vel = 0.93 120 0.0 2.703 T 18.651 77.700 - to 120.0 0.0 18.651 1.169 121 16.59 0.0009 0.0 21.361 0.020 Vel = 0.93 0.0 16.59 78.889 K Factor = 1.87 NEW PATH 223 22.59 2.703 T 18.651 2.710 79.558 0 120.0 0.0 18.651 1.174 222 22.59 0.0016 0.0 21.361 0.035 Vel = 1.26 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 15 2010771 - B1S2RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ""••• Notes '•"'* Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 222 0.0 2.703 2X 33.571 199.970 78.419 to 120.0 0.0 33.571 0.143 122 22.59 0.0016 0.0 233.541 0.379 Vel = 1.26 122 0.0 2.703 T 18.651 2.710 78.655 to Vel = 120.0 0.0 18.651 1.169 123 22.59 0.0016 0.0 21.361 0.035 Vel = 1.26 to 0.0 120.0 2X 0.0 33.571 0.143 22.59 124 ; d 29.68_ 79.859 K Factor = 2.53 NEW PATH 0.0 233.5.41 0.628 ; Vel_= 01.66 _0 225 29.68 2.703 T 18.651 2.710 80.286 to 47.32 120.0 T 0.0 18.651 1.174 224 29.68 0.0027 0.0 21.361 0.058 Vel = 1.66 224 0.0 2.703 2X 33.571 199.970 79.170 Vel'-_ - 2.65 to 0.0 120.0 2X 0.0 33.571 0.143 124 ; d 29.68_ 0.0027 r 0.0 233.5.41 0.628 ; Vel_= 01.66 _0 124 0.0 2.703 T 18.651 2.710 79.655 2.65 to . 0.0 120.0 T 0.0 18.651 1.169 125 _ -29.68 0.0027 0.0 - 21.361 0.058 Vel = 1.66 129 0.0 0.0064 0.0 21.361 0.137 Vel = 2.65 29.68 80.882 K Factor = 3.30 NEW PATH 47.32 83.166 K Factor= 5.19 227 37.91 2.703 T 18.651 2.710 80.956 to 57.94 120.0 T 0.0 18.651 1.174 226 37.91 0.0042 O.0 21.361 _ 0.090 Vel = 2.12_ 226 0.0 2.703 2X 33.571 199.970 79.872 3.24 to 120.0 0.0 33.571 0.143 126 37.91 0.0042 0.0 233.541 0.988 Vel = 2.12 126 0.0 2.703 T 18.651 2.710 80.717 to 120.0 0.0 18.651 1.169 127 37.91 0.0043 0.0 21.361 0.091 Vel = 2.12 0.0 37.91 81.977 K Factor = 4.19 NEW PATH 229 47.32 2.703 T 18.651 2.710 81.553 to 120.0 0.0 18.651 1.174 228 47.32 0.0064 0.0, - 21.361 0.136 Vel'-_ - 2.65 228 0.0 2.703 2X 33.571 199.970 80.515 to 120.0 0.0 33.571 0.143 128_ 47.32 0.0064 0.0 233.541 1.488 Vel = 2.65 128 0.0 2.703 T 18.651 2.710 81.860 to 120.0 0.0 18.651 1.169 129 47.32 0.0064 0.0 21.361 0.137 Vel = 2.65 0.0 47.32 83.166 K Factor= 5.19 NEW PATH 231 57.94 2.703 T 18.651 2.710 - 82.065 0 120.0 0.0 18.651 1.174 230 57.94 0.0093 0.0 21.361 0.198 Vel = 3.24 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 16 2010771 - B1S2RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 230 - 0.0 2.703 - ----_ 2X 33.571 199.970 81.089 - - - - -- -- _ --- - - - -- - -_---- - to 0.0 120.0 0.0 33.571 0.143 130 57.94 0.0093 0.0 233.541 2.165 Vel = 3.24 130 0.0 2.703 T 18.651 2.710 83.111 to 0.0 120.0 0.0 18.651 1.169 131 57.94 0.0093. 0.0 21.361 0.198 Vel = 3.24 0.0 0.0 2X 33.571 199.970 81.587 57.94 to 120.0 84.478 K Factor= 6.30 NEW PATH 140.75 140.75 2.703 120.0 0.0479 T 18.651 0.0 0.0 2.710 18.651 21.361 82.953 1.174 1.023 236 0.0 233 69.81 2.703 T 18.651 2.710 82.481 0.0 33.571 to 136 120.0 0.0479 0.0 18.651 1.174 136 0.0 232 69.81 0.0131 0.0 21.361 0.280 Vel = 3.90 232 0.0 2.703 2X 33.571 199.970 81.587 0.0 to 120.0 0.0 33.571 0.143 132 69.81 0.0131 0.0 233.541 ,, ;__ 3.056 Vel = 3.90 132 0.0 2.703 T 18.651 2.710 84.500 to 120.0 0.0 18.651 1.169 133 69.81 0.0131 0.0 21.361 0.280 Vel = 3.90 0.0 69.81 85.949 -- K Factor = 7.53 NEW PATH 235 129.97 2.703 T 18.651 2.710 82.795 to 120.0 0.0 18.651 1.174 2_3_4 129.9_7_ 0.041_3_ -_ 0.0 - 21.361 _ 0.883 _ Vel = 7.2.7_- 234 0.0 2.703 2X 33.571 216.640 82.504 to 120.0 0.0 33.571 0.156 134 129.97 0.0413 0.0 250.211 10.339 Vel = 7.27 134 0.0 2.703 T 18.651 2.710 92.999 to 120.0 0.0 18.651 1.174 135 129.97 0.0413 0.0 21.361 0.882 Vel = 7.27 0.0 129.97 95.055 K Factor= 13.33 NEW PATH 237 to 236 140.75 140.75 2.703 120.0 0.0479 T 18.651 0.0 0.0 2.710 18.651 21.361 82.953 1.174 1.023 236 0.0 2.703 2X 33.571 216.640 82.802 to 120.0 0.0 33.571 0.156 136 140.75 0.0479 0.0 250.211 11.981 136 0.0 2.703 T 18.651 2.710 94.939 to 120.0 0.0 18.651 1.174 137 140.75 0.0479 0.0 21.361 1.023 0.0 140.75 97.136 Computer Programs by Hydratec Inc. Revision: 50.52.1 Vel = 7.87 Vel = 7.87 Vel = 7.87 K Factor= 14.28 AutoPeaking Summary Wiginton Fire Systems Page 17 2010771 - B1S2RA1 Date 5-19-17 Auto Peaking Summary - List of Pipes for Area Calculated Left Right Side Side From To Length From To Length H4 100 85.210 H1 200 84.730 H8 102 85.210 202 H5 84.730 H12 104 85.210 204 H9 84.730 H4 100 85.210 H1 200 84.730 H8 102 85.210 202 H5 84.730 ' H12 104 85.210 204 H9 84.730 Flow Safety Pressure Required Margin Differential Left 10.000 1709.930 12.212 0.067 Area Calculated 1709.928 12.145 0.000 Right 10.000 1709.970 12.210 0.066 Typical Distance Between Heads = 10.000 Split Point Used in Worst Area Peaked = H3 Split Point Used in Area Calculated = H3 Computer Programs by Hydratec Inc. Revision: 50.52.1 H'Dg)'0MRqM FIRE SYSTEMS Wiginton Fire Systems 699 Aero Lane Sanford, FL 32771 407-585-3200 Job Name 2010771 - B1S3RA1 Drawing FP6 Location BUILDING ONE Remote Area B1S3RA1 Contract 2010771 Data File 2010771 - B1S3RA1.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 W Wiginton Fire Systems 2010771-B1S3RA1 Page 1 Date 5-19-17 Project name: GANESH NORTH Location: BUILDING ONE Drawing no: FP6 Date: 5-19-17 Design HYDRAULIC CALCULATIONS for Remote area number: B1S3RA1 Remote area location: SYSTEM THREE Occupancy classification: HIGH PILED STORAGE Density: 52 PSI - Gpm/SgFt Area of application: 12 HEADS - SgFt Coverage per sprinkler: 100 MAX - SgFt Type of sprinklers calculated: 16.81K ESFR PENDENT No. of sprinklers calculated: 12 In -rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 1713.391 - GPM @ 42.677 - Psi Type of,system: WET Volume' of dry or preaction syst6m: N/A - Gal Water supply information Date: 8-2-16 Location: ALONG W. 1ST STREET Source: WFS Name of contractor: WIGINTON FIRE SYSTEMS Address: 699 AERO LANE, SANFORD, FL 32771 Phone number: 407-585-3200 Name of designer: W. AMMONS Authority having jurisdiction: CITY OF SANFORD Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Revision: 50,52.1 Water ply Curve C Wiginton Fire Systems Page 2 2010771 - B1S3RA1 Date 5-19-17 City Water Supply: C1 - Static Pressure : 60 C2 - Residual Pressure: 50 C2 - Residual Flow : 1840 City Water Adjusted to Pump Inlet for Pf - Elev - Hose Flow Al - Adjusted Static: A2 - Adj Resid A3 - Adj Resid 54.436 33.185 @ 1261.31 10.52 @ 1881.1 Pump Data: P1 - Pump Churn Pressure 126.18 P2 - Pump Rated Pressure 109.95 P2 - Pump Rated Flow 1261.31 P3 - Pump Pressure @ Max Flow 79.39 P3 - Pump Max Flow 1881..x, City Residual Flow @ 0 4846.63 City Residual Flow @ 20 3892.74 City Water @ 150% of Pump 49.58 Demand: 01 - Elevation 14.197 D2 - System Flow 1463.39 D2 - System Pressure 120.681 Hose ( Demand ) D3 - System Demand 1463.39 Hose ( Adj City) 250 Safety Margin 8.559 210 196 182 Al +1P1 p 168 R 154 A2+P2 E 140 S 126 S 112 U 98 R 84 E 70 C1 56 42 Al AZ 28 14 D1 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N^1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Diagram Wiginton Fire Systems 2010771 - B1S3RA1 118.7240.8 481.5 807.3 972 1133 1295.6 1463.4 1463.4 1463.4 H3 +-H4 +-100+-101+-103-105+-107+-109+-111+-113+-115+-117+-119+-121+-123+- 125+- 127+-TR3+-8R3+-PO 240.8 240.8 721.8 890.4 1052.6 1213.9 1378.6 1463.4 1463.4 1463.4 1713.4 1713.4 PI +- SPIG- UG3+- UG4+- UG5+- UG6*- TEST 1463.4 1713.4 1713.4 2.4 246.6 246.6 741.6 573 410.8 249.5 84.8 84.8 H3 +- H2 +- H1 +- 200 +- 201 +- 203 +- 205 +- 207 +- 209 +- 211 +- 213 +- 215 +- 217 +- 219 +- 221 +- 223 +- 222 +- 122 +- 123 123.7 246.6 493.5 656.1 491.4 330.3 167.8 84.8 84.8 Page 3 Date 5-19-17 246.9 124 118.6 240.7 203 - 202 - H5 -* H6 - H7 +- H8 +- 102 +- 103 t 246.9 26 240.7 1 1 493.5 1 481.5 1 248.1 124.9 118 24%3 205 -a 204 - H9 -+ H10 H11 H12+- 104 105 1 248.1 34 240.3 1 741.6 1 85.5 85.5 207 +- 206 +- 106 +- 107 t 85.5 t 1 656.1 1 807.3 1 83.1 83.1 209 +- 208 i- 108 +- 109 1 83.1 1 1 573 1 890.4 1 81.5 81.5 211*- 210+- 110+- 111 1 • 81.5 1 1 095.4 1 972 " 1 80.6 80.0 213+- 212+- 112+- 113 1 80.6 1 1 410.8 1 1052.6 1 80.4 80.4 215 +- 214 +- 114 +- 115 1 80.4 1 1 330.3 1 1133 1 80.8 80.0 217 +- 216 +- 116 +- 117 1 80.8 t 1 249.5 1 1213.9 1 81.7 81.T 219+- 218+- 118+- 119 1 81.7 t 1 167.8 1 1295.6 1 83.1 83.1 221 +- 220 +- 120 +- 121 83.1 Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings d Summary Wiginton Fire Systems Page 4 2010771 - 61 S3RA1 Date 5-19-17 Fitting Legend Abbrev. Name : %: '/. 1 1'/. 1'/: 2 _ 2%x 3 3'/: 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0E90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61GGenericGateValve00000111122345678101113LLongTurnElbow1122234556891316182427303440SGenericSwingCheckValve4557911141619222732455565768798109130T90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121V90'Ell Firelock #001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0X90'Tee-BranchFirelock002 0 0 0 0 0 8.5 10.8 13 0 16 21 25 33 0 0 0 0 0 0 0ZafAmes3000SSFittinggeneratesaFixedLossBasedonFlow Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD Wiginton Fire Systems Page 5 2010771 - B1S3RA1 Date 5-19-17 Node Elevation K -Fact Pt Pn Flow Density Area Press No.__ Actual Actual Req. H3 34.78 16.8 52.0 na 121.15 0.1 100 52.0 H4 35.2 16.8 52.76 na 122.03 0.1 100 52.0 100 34.16 86.53 na 101 31.45 93.43 na 103 31.45 93.44 na 105 31.45 93.5 na 107 31.45 93.63 na 109 31.45 93.78 na 111 31.45 93.96 na 113 31.45 94.18 na 115 31.45 94.43 na 117 31.45 94.72 na 119 31.45 95.04 na 121 31.45 95.41 na 123 31.45 95.83 na 125 31.45 97.23 na 127 29.12 102.06 na TR3 29.12 102.94 na BR3 2.0 119.03 na PO 2.0 120.68 na PI 2.0 26.34 na SPIG -3.0 29.23 na UG3• '' -3.0 32.54'' na 250:0'' UG4 -3.0 43.25 na UG5 -3.0 48.39 na UG6 -3.0 52.19 na TEST 2.0 51.24 na H2 34.41 16.8 52.16 na 121.33 0.1 100 52.0 H1 33.95 16.8 53.48 na 122.86 0.1 100 52.0 00 32.09 74.89 na 01 29.38 82.04 na 203 29.38 82.16 na 205 29.38 82.58 na 207 29.38 83.48 na 209 29.38 84.19 na 211 29.38 84.75 na 213 29.38 85.16 na 215 29.38 85.46 na 217 29.38 85.67 na 219 29.38 85.78 na 221 29.38 85.84 na 223 29.38 85.86 na 222 32.09 85.51 na 122 34.16 93.82 na 202 32.09 74.99 na H5 33.95 16.8 53.54 na 122.92 0.1 100 52.0 H6 34.41 16.8 52.21 na 121.39 0.1 100 52.0 H7 34.78 16.8 52.05 na 121.2 0.1 100 52.0 H8 35.2 16.8 52.81 na 122.09 0.1 100 52.0 102 34.16 86.55 na 204 32.09 75.36 na H9 33.95 16.8 53.73 na 123.14 0.1 100 52.0 H10 34.41 16.8 52.38 na 121.59 0.1 100 52.0 H11 34.78 16.8 52.22 na 121.4 0.1 100 52.0 H12 35.2 16.8 52.98 na 122.28 0.1 100 52.0 104 34.16 86.62 na 206 32.09 83.15 na 106 34.16 91.61 na 208 32.09 83.82 na 108 34.16 91.81 na 210 32.09 84.34 na 110 34.16 92.02 na Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - Standard Wiginton Fire Systems Page 6 2010771 - B1S3RA1 Date 5-19-17 Node Elevation K -Fact Pt Pn Flow Density Area Press No. ActualActual Req. 212 32.09 84.75 na 112 34.16 92.25 na 214 32.09 85.04 na 114 34.16 92.5 na 216 32.09 85.25 na 116 34.16 92.79 na 218 32.09 85.39 na 118 34.16 93.1 na 220 32.09 85.47 na 120 34.16 93.44 na The maximum velocity is 20.88 and it occurs in the pipe between nodes 205 and 204 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 7 2010771 - B1S3RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn EQUIVALENT_ K'S REMOTE HEAD TO SUPPLY H3 118.74 2.203 0.0 10.000 52.000 K Factor = 16.80 to 120.0 0.0 0.0 0.182 H4 118.74 0.0947 0.0 10.000 0.947 Vel = 9.99 H4 122.04 2.203 X 11.593 83.570 52.765 K Factor = 16.80 to 120.0 0.0 11.593 0.450 100 240.78 0.3501 0.0 95.163 33.314 Vel = 20.27 100 0.0 2.203 T 13.639 2.710 86.529 to 120.0 0.0 13.639 1.174 101 240.78 0.3501_ 0.0 16.349 5.723 Vel = 20.27 101 0.0 6.385 0.0 8.330 93.426 to 120.0 0.0 0.0 0.0 103 240.780.0020 0.0 8._330 0.017 Vel = 2.41. 103 240.68 6.385 0.0 8.330-i 93.443 to 120.0 0.0 0.0 0.0 105 481.46 0.0071 0.0 8.330 0.059 Vel = 4.82 105 240.32 6.385 0.0 8.330 93.502 to 120.0 0.0 0.0 0.0 107 721.78 0.0150 0.0 8.330 0.125 Vel = 7.23 107 85.52 6.385 0.0 8.330 93.627 to 120.0 0.0 0.0 0.0 109 807.3 0.0184 0.0 8.330 0.153 Vel = 8.09 109 83.14 6.385 0.0 8.330 93.780 to 120.0 0.0 0.0 0.0 111 890.44 0.0221 0.0 8.330 0.184 _ Vel = 8.92 111 81.53 6.385 0.0 8.330 93.964 to 120.0 0.0 0.0 0.0 113 971.97 0.0261 _ 0.0 8.330 0.217 Vel = 9.74 113 80.65 6.385 0.0 8.330 94.181 to 120.0 0.0 0.0 0.0 115 1052.62 0.0301 0.0 8.330 0.251 Vel = 10.55 115 80.43 6.385 0.0 8.330 94.432 to 120.0 0.0 0.0 0.0 117 1133.05 0.0345 0.0 8.330 0.287 Vel = 11.35 117 80.81 6.385 0.0 8.330 94.719 to 120.0 0.0 0.0 0.0 119 1213.86 0.0391 0.0 _ 8.330 0.326 Vel = 12.16 119 81.72 6.385 0.0 8.330 95.045 to 120.0 0.0 0.0 0.0 121 1295.58 0.0443 0.0 8.330 0.369 Vel = 12.98 121 83.06 6.385 0.0 8.330 95.414 to 120.0 0.0 0.0 0.0 123 1378.64 0.0496 0.0 8.330 0.413 Vel = 13.81 123 84.75 6.385 V 12.845 12.500 95.827 to 120.0 0.0 12.845 0.0 125 1463.39 0.0554 0.0 25.345 1.404 Vel = 14.66 125 0.0 6.385 V 12.845 56.040 97.231 to 120.0 0.0 12.845 1.009 127 1463.39 0.0554 0.0 68.885 3.816 Vel = 14.66 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 8 2010771 - B1S3RA1 Date 5-19-17 Hyd, Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 127 0.0 6.385 V 12.845 3.080 102.056 to 120.0 120.681 0.0 12.845 0.0 TR3 1463.39 0.0554 0.0 0.0 15.925 0.882 Vel = 14.66 TR3 0.0 6.385 T 38.536 27.120 102.938 to 1713.39 120.0 B 12.845 51.381 11.746 BR3 1463.39 0.0554 0.0 78.501 4.347 Vel = 14.66 BR3 0.0 8.249 2V 28.914 11.375 119.031 to 38.923 120.0 B 13.345 92.303 0.0 PO 1463.39 0.0159 S 50.044 103.678 1.650 Vel = 8.79 0.0 0.0 12.34 T 88.164 450.000 52.189 1463.39 to 140.0 120.681 K Factor = 133.21 System Demand Pressure TEST 1713.39 120.681 0.0 Safety Margin 1.213 Vel = 4.60 8.559 Continuation Pressure 129.240 1713.39 Pressure @ Pump,Outlet 51.236 129.240 a Pressure From Pump Curve 102.903 H3 Pressure @ Pump Inlet 2.203 0.0 9.000 26.337 PI 0.0 8.249 T 38.923 2.500 26.337 0.160 to 120.0 G 4.448 43.371 2.166 9.000 SPIG 14_63.39_ _0.0159 0.0 45.871_ 0.729 29.232 ----- Vel = 8.79 SPIG 0.0 8.27 E 26.955 195.000 to 140.0 T 52.413 85.358 0.0 123.74 UG3 1463.39 _ 0.0118_ G 5.99 280.358 3.313 Vel = 8.74_ UG3 250.00 8.27 T 52.413 300.000 32.545 Qa = 250 to 140.0 Zaf 0.0 130.283 3.901 Fixed Loss = 3.901 UG4 1713.39 0.0158 _ 4L 77.87 430.283 6.807 Vel = 10.23 UG4 0.0 10.28 T 71.092 865.000 43.253 to 140.0 0.0 71.092 0.0 UG5 1713.39 0.0055 0.0 936.092 5.133 Vel = 6.62 UG5 0.0 12.34 T 88.164 1600.000 48.386 to 140.0 0.0 88.164 0.0 UG6 1713.39 0.0023 0.0 1688.164 3.803 Vel = 4.60 UG6 0.0 12.34 T 88.164 450.000 52.189 to 140.0 0.0 88.164 2.166 TEST 1713.39 0.0023 0.0 538.164 1.213 Vel = 4.60 0.0 1713.39 51.236 K Factor = 239.37 NEW PATH H3 2.40 2.203 0.0 9.000 52.000 to 120.0 0.0 0.0 0.160 H2 2.4 0.0001 0.0 9.000 0.001 Vel = 0.20 H2 121.34 2.203 0.0 11.000 52.161 K Factor = 16.80 to 120.0 0.0 0.0 0.199 H1 123.74 0.1022 0.0 11.000 1.124 Vel = 10.42 H1 122.86 2.203 X 11.593 44.700 53.484 K Factor = 16.80 to 120.0 0.0 11.593 0.806 200 246.6 0.3659 0.0 56.293 20.597 Vel = 20.76 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems 2010771 - B1S3RA1 Page 9 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv "••••• Notes "•"` Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 200 0.0 2.203 T 13.639 2.710 74.887 to to 0.0 120.0 0.0 13.639 1.174 0.0507 0.0 _ 201 246.6 0.3659 0.0 16.349 5.982 Vel = 20.76 201. 0.0 4.304 0.0 8.330 82.043 123 84.75 to 0.0 120.0 0.0 0.0 0.0 203 246.6 0.0140 0.0 8.330 0.117 Vel = 5.44 203 246.92 4.304 0.0 8.330 82.160 to 120.0 0.0 0.0 0.0 205 493.52 0.0505 0.0 8.330 0.421 Vel = 10.88 205 248.09 4.304 0.0 8.330 82.581 to 120.0 0.0 0.0 0.0 207 741.61 0.1076 0.0 8.330 0.896 Vel = 16.35 207 85.51 4.304 0.0 8.330 83.477 to 120.0 0.0 0.0 0.0 209 656.1 0.0857 0.0 8.330 0.71_4 Vel = 14.47 209 83.14 4.304 0.0 8.330 84.191 to 120.0 0.0 0.0 0.0 211 572.96 _-0.0667 0.0 8.330 0.556 Vel = 12.63 211 81.54 4.304 0.0 8.330 84.747 to 120.0 0.0 0.0 0.0 213 _ _ 491.42 0.0502 _ _ 0.0_ - 8.330 0.418 _ Vel = 10.84 213 80.65 4.304 0.0 8.330 85.165 to 120.0 0.0 0.0 0.0 215 410.77 0.0360_ 0.0 8.330 0.3_00 Vel = 9.06_ 215 80.43 4.304 0.0 8.330 85.465 to 120.0 0.0 0.0 0.0 217 ----- 330.34 0.0241 -- 0.0 8.330 0.201 Vel = 7.28 217 80.81 4.304 0.0 8.330 85.666 to 120.0 0.0 0.0 0.0 219 249.53 0.0143 0.0 8.330 0.119 Vel = 5.50 219 81.72 4.304 0.0 8.330 85.785 to 120.0 0.0 0.0 0.0 221 167.81 0.0070 0.0 8.330 0.058 Vel = 3.70 221 83.06 4.304 0.0 8.330 85.843 to 120.0 0.0 0.0 0.0 223 84.75 0.0019 0.0 8.330 0.016 Vel = 1.87 223 0.0 2.203 T 13.639 2.710 85.859 to 120.0 0.0 13.639 1.174 222 84.75 0.0507 0.0 16.349 0.829 Vel = 7.13 222 0.0 2.203 2X 23.186 158.300 85.514 to 120.0 0.0 23.186 0.897 122. 84.75 0.0507 0.0 _ 181.486 9.207 Vel = 7.13 122 0.0 2.203 T 13.639 2.710 93.824 to 120.0 0.0 13.639 1.174 123 84.75 0.0507 0.0 16.349 0.829 Vel = 7.13 0.0 84.75 95.827 K Factor= 8.66 NEW PATH Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 10 2010771 - B1S3RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv rrrrrrr Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 203 -246.92 2.203 T 13.639 2.710 82.160 to 120.0 0.0 13.639 -1.174 202 -246.92 -0.3668 0.0 16.349 -5.997 Vel = 20.78 202 0.0 2.203 X 11.593 44.700 74.989 82.581 to to 120.0 0.0 11.593 0.806 13.639 H5 246.92 0.3668 0.0 56.293 20.647 Vel = 20.78 H5 122.92 2.203 0.0 11.000 53.536 K Factor = 16.80 to 44.700 120.0 0.0 0.0 0.199 120.0 H6 124.0 0.1025 0.0 11.000 1.128 Vel = 10.44 H6 121.39 2.203 0.0 9.000 52.209 K Factor = 16.80 to 2.203 120.0 0.0 0.0 0.160 K Factor = 16.80 H7 ___ 2.61 0.0001 0.0 _ 9.000 0.00_1 _ _ Vel = 0.22 H7 121.20 2.203 0.0 10.000 52.048 K Factor = 16.80 to Vel = 10.52 120.0 0.0 0.0 0.182 0.0 H8 118.59,_ 0.0944 L0.0_ 10.000 0.944 Vel = 9.98 H8 122.09 2.203 X 11.593 83.570 52.810 K Factor = 16.80 to 0.0 120.0 0.0 11.593 0.450 121.40 102 240.68 0.3498 0.0 95.163 33.290 Vel = 20.26 102 0.0 2.203 T 13.639 2.710 86.550 to 118.05 120.0 0.0 13.639 1.174 0.936 103 240.68 0.3498 0.0 16.349 5.719 Vel = 20.26 52.975 0.0 to 120.0 0.0 11.593 240.68 104 240.33 93.443 K Fnr-tnr = 7d Un NEW PATH 205 248.08 2.203 T 13.639 2.710 82.581 to 120.0 0.0 13.639 1.174 204 248.08 0.3699 0.0 16.349 6.048 Vel = 20.88_ 204 0.0 2.203 X 11.593 44.700 75.359 to 120.0 0.0 11.593 0.806 H9 248.08 0.3700 0.0 56.293 20.827 Vel = 20.88 H9 123.14 2.203 0.0 11.000 53.726 K Factor = 16.80 to 120.0 0.0 0.0 0.199 H10 124.94 0.1041 0.0 11.000 1.145 Vel = 10.52 H10 121.59 2.203 0.0 9.000 52.382 K Factor = 16.80 to 120.0 0.0 0.0 0.160 H11 3.35 0.0001 0.0 9.000 0.001 Vel = 0.28 H11 121.40 2.203 0.0 10.000 52.221 K Factor = 16.80 to 120.0 0.0 0.0 0.182 H12 _ 118.05 0.093_6 0.0 10.000 0.936 Vel = 9.94 H12 122.28 2.203 X 11.593 83.570 52.975 K Factor = 16.80 to 120.0 0.0 11.593 0.450 104 240.33 0.3489 0.0 95.163 33.200 Vel = 20.23 104 0.0 2.203 T 13.639 2.710 86.625 to 120.0 0.0 13.639 1.174 105 240.33 0.3488 0.0 16.349 5.703 Vel = 20.23 0.0 240.33 93.502 K Factor = 24.85 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 11 2010771 - B1S3RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn NEW PATH 207 85.51 2.203 T 13.639 2.710 83.477 84.191 to 120.0 0.0 13.639 1.174 0..0.) 206 85.51 0.0516 0.0 16.349. 0.843 Vel = 7.20 206 0.0 2.203 2X 23.186 158.300 83.146 208 to 2.203 120.0 0.0 23.186 0.897 106 85.51 0.0516 0.0 181.486 9.361 Vel = 7.20 106 0.0 2.203 T 13.639 2.710 91.610 0.0 to 181.486 120.0 0.0 13.639 1.174 0.0 107 85.51 0.0516 0.0 16.349 0.843 Vel = 7.20 to 0.0 120.0 0.0 13.639 1.174 85.51 109 _ 83.14 0.0489 93.627 K Factor= 8.84 NEW PATH 0.800 Vel = V 7.00 0.0 209 83.14 2.203 T 13.639 2.710 84.191 alto 1,20.0 0..0.) 13.639 1;174 d 208 _ _ 83.14 0.0490 0.0 ------ 16.349 0.801 Vel = 7.00 208 0.0 2.203 2X 23.186 158.300 83.818 to 120.0 0.0 23.186 0.897 108 83.14 0.0490 _ 0.0 181.486 8.885 Vel = 7.00 108 0.0 2.203 T 13.639 2.710 91.806 to 120.0 0.0 13.639 1.174 109 _ 83.14 0.0489 0.0 16.349 0.800 Vel = V 7.00 0.0 83.14 93.780 _ _ _ K Factor = 8.59 NEW PATH 211 81.53 2.203 T 13.639 2.710 84.747 to 120.0 0.0 13.639 1.174 210 81.53 0.0472 0.0 16.349 0.772 Vel = 6.86 210 0.0 2.203 2X 23.186 158.300 84.345 to 120.0 0.0 23.186 0.897 110 81.53 0.0472 0.0 181.486 8.570 Vel = 6.86 110 0.0 2.203 T 13.639 2.710 92.018 to 120.0 0.0 13.639 1.174 111 81.53 0.0472 0.0 16.349 0.772 Vel = 6.86 0.0 81.53 93.964 K Factor = 8.41 , . NEW PATH 213 80.65 2.203 T 13.639 2.710 85.165 to 120.0 0.0 13.639 1.174 212 80.65 0.0463 _ 0.0 16.349 0.757 Vel = 6.79 212 0.0 2.203 2X 23.186 158.300 84.748 to 120.0 0.0 23.186 0.897 112 80.65 0.0463 0.0 181.486 8.399 Vel = 6.79 112 0.0 2.203 T 13.639 2.710 92.250 to 120.0 0.0 13.639 1.174 113 80.65 0.0463 0.0 16.349 _ 0.757 Vel = 6.79 0.0 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 12 2010771 - B1S3RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv '•""' Notes •""' Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 80.65 94.181 K Factor= 8.31 NEW PATH 215 80.43 2.203 T 13.639 2.710 85.465 16.349 120.0 to 23.186 120.0 118 0.0 13.639 1.174 181.486 8.606 Vel = 6.88 214 80.43 0.0461 T 13.639 0.0 16.349 0.753 Vel = 6.77 214 0.0 2.203 2X 23.186 158.300 85.044 16.349 0.775 Vel = 6.88 to 0.0 120.0 0.0 23.186 0.897 81.72 114 80.43 0.0461 0.0 181.486 8.358 Vel = 6.77 114 0.0 2.203 T 13.639 2.710 92.505 to 120.0 0.0 13.639 1.174 115 80.43 0.0461 0.0 16.349 0.753 Vel = 6.77 0.0 80.43 94.432 K Factor= 8.28 NEW PATH 217 80.81 2.203 T 13.639• '' 2.710 85.6661 to 120.0 0.0 13.639 1.174 216 _ _ 80.81 0.0465 -------0.0 1_6.349_______ 0.760 - 6_._8.0_ 216 0.0 2.203 2X 23.186 158.300 85.252 Vel to 120.0 0.0 23.186 0.897 116 80.81 0.0465 0.0 181.486 8.431 Vel = 6.80 116 0.0 2.203 T 13.639 2.710 92.786 to 120.0 0.0 13.639 1.174 1-17 80.81 0.0464 ------- 0.0 16.349 0.759 Vel = 6.80 0.0 80.81_- 94.719 -__ K Factor= 8.30_ NEW PATH 219 81.72 2.203 T 13.639 2.710 85.785 to 120.0 0.0 13.639 -1.174 218 81.72 0.0475 0.0 16.349 0.776 Vel = 6.88 218 0.0 2.203 2X 23.186 158.300 85.387 to 16.349 120.0 0.0 23.186 0.897 118 81.72 0.0474 0.0 181.486 8.606 Vel = 6.88 118 0.0 2.203 T 13.639 2.710 93.096 to 16.349 120.0 0.0 13.639 1.174 119 81.72 0.0474 0.0 16.349 0.775 Vel = 6.88 0.0 81.72 95.045 K Factor = 8.38 NEW PATH 2.710 _- 221 83.06 2.203 to 16.349 120.0 220 83.06 0.0489 220 0.0 2.203 to 181.486 120.0 120 83.06 0.0489 120 0.0 2.203 0 16.349 120.0 121 83.06 0.0489 T - - 13.639 2.710 _- 85.843 - -- --- 0.0 13.639 1.174 0.0 16.349 0.799 2X 23.186 158.300 85.468 0.0 23.186 0.897 0.0 181.486 8.870 T 13.639 2.710 93.441 0.0 13.639 1.174 0.0 16.349 0.799 Computer Programs by Hydratec Inc. Revision: 50.52.1 Vel = 6.99 Vel = 6.99 Vel = 6.99 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 13 2010771 - B1S3RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv "•••'• Notes '•'•" Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 83.06 95.414 K Factor= 8.50 Computer Programs by Hydratec Inc. Revision: 50.52.1 AutoPeaking Summary Wiginton Fire Systems Page 14 2010771 - B1S3RA1 Date 5-19-17 Auto Peaking Summary - List of Pipes for Area Calculated Left Right Side Side From To Length From To Length H4 100 83.570 H1 200 44.700 H8 102 83.570 202 H5 44.700 H12 104 83.570 204 H9 44.700 H4 100 83.570 H1 200 44.700 H8 102 '''' 83.570 202 H5 44700 H12 104 83.570 204 H9 44.700 Flow Safety Pressure Required Margin Differential Left 10.000 1713.168 8.703 0.145 Area Calculated 1713.391 8.559 0.000 Right 10.000 1713.787 8.854 0.295 Typical Distance Between Heads = 10.000 Split Point Used in Worst Area Peaked = H3 Split Point Used in Area Calculated = H3 Computer Programs by Hydratec Inc. Revision: 50.52.1 M 0 0 Rom FIRE SYSTEMS Wiginton Fire Systems 699 Aero Lane Sanford, FL 32771 407-585-3200 Job Name 2010771'- B1S4RA1 Drawing FP7/FP8 Location BUILDING ONE Remote Area B1S4RA1 Contract 2010771 Data File 2010771 - B1S4RA1.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 M Wiginton Fire Systems 2010771 - B1S4RA1 Page 1 Date 5-19-17 HYDRAULIC CALCULATIONS for Project name: GANESH NORTH Location: BUILDING ONE Drawing no: FP7/FP8 Date: 5-19-17 Design Remote area number. B1S4RA1 Remote area location: SYSTEM FOUR Occupancy classification: HIGH PILED STORAGE Density: 52 PSI - Gpm/SgFt Area of application: 12 HEADS - SgFt Coverage per sprinkler: 100 MAX - SgFt Type of sprinklers calculated: 16.8K ESFR PENDENT No. of sprinklers calculated: 12 In -rack demand. N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 1710.737 - GPM Type of system: WET- Volume of dry or preaction system: N/A - Gal Water supply information Date: 8-2-16 Location: ALONG W. 1ST STREET Source: WFS Name of contractor. WIGINTON FIRE SYSTEMS Address: 699 AERO LANE, SANFORD, FL 32771 Phone number. 407-585-3200 Name of designer. W. AMMONS Authority having jurisdiction: CITY OF SANFORD Notes: (Include peaking information or gridded systems here.) @ 33.655 - Psi Computer Programs by Hydratec Inc. Revision: 50.52.1 Water )ly Curve C Wiginton Fire Systems Page 2 2010771 - B1S4RA1 Date 5-19-17 City Water Supply: C1 - Static Pressure 60 C2 - Residual Pressure: 50 C2 - Residual Flow 1840 City Water Adjusted to Pump Inlet for Pf - Elev - Hose Flow 1261.31 Al - Adjusted Static: 54.436 A2 - Adj Resid A3 - Adj Resid 33.185 @ 1261.31 10.52 @ 1881.1 Pump Data: P1 - Pump Churn Pressure 126.18 P2 - Pump Rated Pressure 109.95 P2 - Pump Rated Flow 1261.31 P3 - Pump Pressure @ Max Flow 79.39 P3 - Pump Max Flow 1881.1 City Residual Flow @ 0 4846.63 City Residual Flow @ 20 3892.74 City Water @ 150% of Pump 49.58. Demand: D1 - Elevation 14.890 D2 - System Flow 1460.74 D2 - System Pressure 111.833 Hose ( Demand ) D3 - System Demand 1460.74 Hose ( Adj City) 250 Safety Margin 17.606 210 196 AI+P1 182 p 168 R 154 A2+P2 E 140 S 126 D2 S 112 U 98 R 84 E 70 C1 56 42 AZ 28 14 D1 200 400 600 800 1000 1200 1400 1600 1800 FLOW N^1.85) Computer Programs by Hydratec Inc. Revision:; 50.52.1 Flow D am Wiginton Fire Systems 2010771 - B1S4RA1 119.6 241.3 483.4 787.2 893.9 982.6 1061.1 1137.6 1219.9 1314.1 1460.7 1460.7 1460.7 H3 +- H4 +- 100 +- 101 + 103 +- 105 +- 107 + 109 +- 111 +- 113 + 115 +- 117 119 +- 121 +- 123 +- 125 +- 127 t 129 +- 131 +-"133 i- 135 +- 137 139 F TR4<- BR4F PO 241.3 241.3 724.7 843.3 940 10226 1099.1 1177.6 1265.2 1366.9 1460.7 1460.7 1460.7 1710.7 1710.7 PI +- SPlr- UG3+- UG4+- UG5i- UG6+- TEST 1460.7 1710.7 1710.7 1.6 244.9 244.9 736.1 617.4 520.7 438.1 361.6 283.1 195.5 93.8 93.8 H3 +- H2 +- Hi F 200 +- 201 203 +- 205 +- 207 +- 209 F 211 +- 213 +- 215 +- 217 +- 219 + 221 +- 223 +- 225 +- 227 <- 229 F 231 +- 233 +- 235 +- 234 +- 134 135 122.9 2449 489.6 6735 566.8 478.1 399.6 323.1 240.8 146.7 93.8 93.8 244.7 122.6 120.2 242.1 203 - 202 H5 -+ H6 H7 H8 +- 102 + 103 T 244.7 1.1 242.1 t 1 489.6 1 483.4 1 246.4 124.1 119.1 24143 205 - 204 -+ H9 - H10- H/1 e- H12+ 104+- 105 T 246.4 2.4 241.3 1 736.1 1 62.5 625 207+- 206+- 106+- 107 t 62.5 t 1 673.5 1 787.2 1 56.1 56.1 209+ 208(.- 108+ 109 T 56.1 t 1 617.4 1 843.3 1 50.6 50.6 211 210+- 110+- 111 T 50.6 t 1 566.8 1 893.9 1 46.1 46.1 213+ 212+- 112+ 113 T 461 t 1 520.7 1 940 1 42.6 42.6 215+- 214+- 114+ 115 T 42.6 t 1 478.1 1 982.6 1 40 401 217+- 216+- 116+- 117 t 40 t 1 438.1 1 1022.6 1 38.5 38.$ 219+- 218+- 118+- 119 T 38.5 t 1 399.6 1 1061.1 1 38 381 221 + 220 +- 120+- 121 t 38 t 1 361.6 1 10991 1 38.5 38.5 223+- 222 + 122*- 123 t 38.5 t 1 323.1 1 1137.6 1 40 401 225+- 224 F 124+- 125 T 40 t 1 283.1 1 1177.6 Computer Programs by Hydratec Inc. Revision: 50.52.1 Page 3 Dafe 5-19-17 Flow [ am Wiginton Fire Systems 2010771 - 61 S4RA1 Page 4 Date 5-19-17 1 42.3 42.0 227 F 226 +-126 +- 127 T 42.3 T 1 240.8 1 1219.9 1 45.3 45.} 229 +- 228 128 +- 129 T 45.3 T 1 195.5 1 1265.2 1 48.8 48.a 231 230. 130. 131 T 48.8 T 1 146.7 1 1314.1 1 52.9 52 V 233 +- 232 +- 132 E- 133 52.9 Computer Programs by Hydratec Inc. Revision: 50.52.1 Fitting d Summary Wiginton Fire Systems Page 5 2010771 - 131S4RA1 Date 5-19-17 Fitting Legend Abbrev_ Name _ '/: '/. 1 1'/. 1 %: 2 2'% 3 3'/: 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0E90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 _ 12 14 18 22 27 35 40 45 50 61GGenericGateValve00000111122345678101113LLongTumElbow1122234 * 5 5 6 8 9 13 16 18 24 27 30 34 40SGenericSwingCheckValve4557911141619222732455565768798109130T90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121V90'Ell Firelock #001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0X90'Tee-BranchFirelock002 0 0 0 0 0 8.5 10.8 13 0 16 21 25 33 0 0 0 0 0 0 0ZafAmes3000SSFittinggeneratesaFixedLossBasedonFlow Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD Wiginton Fire Systems Page 6 2010771 - B1S4RA1 Date 5-19-17 lode Elevation K -Fact Pt Pn Flow Density Area Press No. - - Actual Actual H3 36.38 16.8 52.0 na 121.15 0.1 100 52.0 H4 35.97 16.8 52.53 na 121.76 0.1 100 52.0 100 32.03 68.95 na 101 29.37 76.34 na 103 29.37 76.36 na 105 29.37 76.42 na 107 29.37 76.55 na 109 29.37 76.69 na 111 29.37 76.86 na 113 29.37 77.04 na 115 29.37 77.25 na 117 29.37 77.47 na 119 29.37 77.71 na 121 29.37 77.96 na 123 29.37 78.23 na 125 29.37 78.52 na 127 29.37 78.83 na 129 29.37 79.16 na 131 29.37 79.51 na 133 29.37 79.89 na 135 29.37 83.59 na 137 29.37 90.11 na 139 • 29.55 93.38 na TR4 29.55 94.14 na BR4 2.0 110.46 na PO 2.0 111.83 na PI 2.0 26.43 na SPIG -3.0 29.32 na UG3 -3.0 32.62 na 250.0 IG4 -3.0 43.31 na iG5 -3.0 48.43 na UG6 -3.0 52.22 na TEST 2.0 51.26 na H2 36.03 16.8 52.15 na 121.32 0.1 100 52.0 H1 35.62 16.8 52.7 na 121.96 0.1 100 52.0 200 32.09 67.77 na 201 29.38 71.8 na 203 29.38 71.91 na 205 29.38 72.33 na 207 29.38 73.21 na 209 29.38 73.96 na 211 29.38 74.6 na 213 29.38 75.14 na 215 29.38 75.61 na 217 29.38 76.0 na 219 29.38 76.34 na 221 29.38 76.63 na 223 29.38 76.87 na 225 29.38 77.06 na 227 • 29.38 77.21 na 229 29.38 77.32' na 231 29.38 77.4 na 233 29.38 77.44 na 235 29.38 77.46 na 234 32.09 76.77 na 134 33.76 80.6 na 202 32.09 67.89 na H5 35.62 16.8 52.83 na 122.11 0.1 100 52.0 H6 36.03 16.8 52.29 na 121.48 0.1 100 52.0 H7 36.38 16.8 52.13 na 121.3 0.1 100 52.0 H8 35.97 16.8 52.67 na 121.92 0.1 100 52.0 102 32.03 68.93 na Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - Standard Wiginton Fire Systems Page 7 2010771 - B1S4RA1 Date 5-19-17 lode Elevation K -Fact Pt Pn Flow Density Area Press No. Actual Actual Req_ 204 32.09 68.27 na H9 35.62 16.8 53.04 na 122.35 0.1 100 52.0 H10 36.03 16.8 52.48 na 121.7 0.1 100 52.0 H11 36.38 16.8 52.33 na 121.53 0.1 100 52.0 H12 35.97 16.8 52.86 na 122.14 0.1 100 52.0 104 32.03 69.03 na 206 32.09 72.26 na 106 32.03 74.88 na 208 32.09 72.97 na 108 32.03 75.12 na 210 32.09 73.58 na 110 32.03 75.36 na 212 32.09 74.1 na 112 32.03 75.6 na 214 32.09 74.55 na 114 32.03 75.84 na 216 32.09 74.93 na 116 32.03 76.09 na 218 32.09 75.26 na 118 32.03 76.35 na 220 32.09 75.55 na 120 32.03 76.6 na 222 32.09, ' 75.79 na 122 32.03 76.87 na 224 32.09 75.98 na 124 32.03 77.15 na 226 32.09 76.15 na 126 32.03 77.43 na 228 32.09 76.27 na 128 32.03 77.73 na 30 32.09 76.37 na 130 32.03 78.04 na 232 32.09 76.44 na 132 32.03 78.36 na The maximum velocity is 16.23 and it occurs in the pipe between nodes 205 and 207 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems 2010771 - B1S4RA1 Page 8 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv "'•"' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn EQUIVALENT K'S REMOTE HEAD TO SUPPLY H3 119.56 2.703 0.0 10.000 52.000 K Factor = 16.80 to 120.0 120.0 0.0 0.0 0.178 1137.65 0.0348_ H4 119.56 0.0354 0.0 10.000 0.354 Vel = 6.68 H4 121.76 2.703 T 18.651 94.650 52.532 K Factor = 16.80 to 1177.65 120.0 0.0 18.651 1.706 100 241.32 0.1298 0.0 113.301 14.710 Vel = 13.49 100 0.0 2.703 T 18.651 29.450 68.948 to 120.0 0.0 18.651 1.152 101 241.32 0.1298 0.0 48.101 6.245 Vel = 13.49 101 0.0 6.385 0.0 8.330 76.345 to 120.0 0.0 0.0 0.0 103 241.32 0.0019 _ 0.0 8.330_ 0.016 Vel = 2.42 1,103 242.09 6:385 0.0, ; 8.330 76.3.61 a to 120.0 0.0 0.0 0.0 105 _ 483.41 0.0072 __ 0.0 8_330 0.060 _ Vel = 4.84 105 241.27 6.385 0.0 8.330 76.421 to 120.0 0.0 0.0 0.0 107 724.68 0.0150 0.0 _ 8.330 0.125 _ _ Vel = 7.26 107 62.51 6.385 0.0 8.330 76.546 to 120.0 0.0 0.0 0.0 10-9-787.19 0.0176 -- 6.385 _ - 0.0 0.0 - 8.330 _ 0.147 Vel = 7.89 109 56.11 8.330 76.693to120.0 0.0 0.0 0.0 111 843.3 0.0199 0.0 8.33_0 0.166 _ Vel = 8.45_ 111 50.64 6.385 0.0 8.330 76.859 to 120.0 0.0 0.0 0.0 113 893.94 0.0223 0.0 8.330 0.186 Vel = 8.96 113 46.11 6.385 0.0 8.330 77.045 to 120.0 0.0 0.0 0.0 115 940.05 0.0244 0.0 8.330 0.203 Vel = 9.42 115 42.55 6.385 0.0 8.330 77.248 to 120.0 0.0 0.0 0.0 117 982.6 0.0265 0.0 8.330 0.221 Vel = 9.85 117 40.00 6.385 0.0 8.330 • 77.469 to 120.0 0.0 0.0 0.0 119 1022.6 0.0286 0.0 8.330 0.238 Vel = 10.25 119 38.49 6.385 0.0 8.330 77.707 to 120.0 0.0 0.0 0.0 121 1061.09 _ 0.03_05_ _ 0.0 8.330 0.254 Vel = 10.63 121 38.01 6.385 0.0 8.330 77.961 to 120.0 0.0 0.0 0.0 123 1099.1 0.0327 0.0 8.330 0.272 Vel = 11.01 123 38.55 6.385 0.0 8.330 78.233 to 120.0 0.0 0.0 0.0 125 1137.65 0.0348_ 0.0 8.330 0.290 Vel = 11.40 125 40.00 6.385 0.0 8.330 78.523 to 120.0 0.0 0.0 0.0 127 1177.65 0.0370 0.0 8.330 0.308 Vel = 11.80 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems 2010771 - B1S4RA1 Page 9 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ""••` Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 127 42.29 6.385 0.0 8.330 78.831 - - - - -- - - to 129.439 120.0 0.0 0.0 0.0 129 1219.94 0.0396 0.0 8.330 0.330 Vel = 12.22 129 45.27 6.385 0.0 8.330 79.161 to Vel = 120.0 0.0 0.0 0.0 131 1265.21 0.0423 0.0 8.330 0.352 Vel = 12.68 131 48.85 6.385 17.606 0.0 8.330 79.513 129.439 Pressure From Pump Curve to Pressure @ Pump Inlet 120.0 PI 0.0• 8.249 0.0 0.0 0.0 SPIG 1460.74 0.0158 0.0 45.871 0.727 Vel = 8.77 133 1314.06 0.0455 280.358 _ 0.0 8.330 0.379 Vel = 13.17 133 52.87 6.385 2V 25.691 50.000 79.892 140.0 Zaf to 130.283 120.0 Fixed Loss = 3.896 0.0 25.691 0.0 4L 77.87 135 1366.93 0.0488 UG4 0.0 75.691 3.695 Vel = 13.70 135 93.81 6.385 V 12.845 105.350 83.587 71.092 0.0 to UG5 120.0 0.0055 0.0 12.845 0.0 5.118 Vel = 6_.6.1 137 ;,, 14.60.74 0.0552, 0.0 118.195 _ 6.525 Vel = 14.64- 137 0.0 6.385 V 12.845 47.710 90.112 UG6 1710.74 to 120.0 1688.164 0.0 12.845 0.078 139 1460.74 0.0552 0.0 60.555 3.343 Vel = 14.64 139 0.0 6.385 V 12.845 1.000 93.377 to 120.0 0.0 12.845 0.0 TR4 1460.74 0.0552 0.0 13.845 0.764 Vel = 14.64 TR4 0.0 6.357 T 37.72 27.500 94.141 to 120.0 B 12.573 50.293 11.932 BR4 146.0.74 0.0564 0.0 14.457 - 77_.793 4.3_88 110.461 -_ - - -_ Vel = 14.77 BR4 0.0 8.249 V 8.666 to 120.0 B 13.345 77.846 0.0 PO 1460.74 0.0159 S 50.044 86.512 1.372 Vel = 8.77 0.0 1460.74 111.833 K Factor = 138.13 System Demand Pressure 111.833 Safety Margin 17.606 Continuation Pressure 129.439 Pressure @ Pump Outlet 129.439 Pressure From Pump Curve 103.010 Pressure @ Pump Inlet 26.429 PI 0.0• 8.249 T • 38.923 2.500 26.429 to 120.0 G 4.448 43.371 2.166 SPIG 1460.74 0.0158 0.0 45.871 0.727 Vel = 8.77 SPIG 0.0 8.27 E 26.955 195.000 29.322 to 140.0 T 52.413 85.358 0.0 UG3 1460.74 0.0118 G 5.99 280.358 _ 3.302 Vel = 8.72 UG3 250.00 8.27 T 52.413 300.000 32.624 Qa = 250 to 140.0 Zaf 0.0 130.283 3.896 Fixed Loss = 3.896 UG4 1710.74 0.0158 4L 77.87 430.283 6.787 Vel = 10.22 UG4 0.0 10.28 T 71.092 865.000 43.307 to 140.0 0.0 71.092 0.0 UG5 1710.74 0.0055 0.0 93_6.092 5.118 Vel = 6_.6.1 UG5 0.0 12.34 T 88.164 1600.000 48.425 to 140.0 0.0 88.164 0.0 UG6 1710.74 0.0022 0.0 1688.164 3.792 Vel = 4.59 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 10 2010771 - B1S4RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv '•"•" Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UG6 0.0 12.34 T 88.164 450.000 52.217 to 140.0 0.0 88.164 -2.166 TEST 1710.74 0.0022 0.0 538.164 1.210 Vel = 4.59 0.0 1710.74 51.261 K Factor = 238.94 NEW PATH H3 1.59 2.703 0.0 10.000 52.000 to 120.0 0.0 0.0 0.152 H2 1.59 0.0 0.0 10.000 0.0 Vel = 0.09 H2 121.32 2.703 0.0 10.000 52.152 K Factor = 16.80 to 120.0 0.0 0.0 0.178 H1 122.91 0.0372 0.0 10.000 0.372 Vel = 6.87 H1 121.96 2.703 X 16.786 84.740 52.702 K Factor = 16.80 to 120.0 0.0 16.786 1.529 o 200 244.87 0.1334 - 0.0:1- _ 101.526_ 13.542 _- Vel = 13.6.9_ 200 0.0 2.703 T 18.651 2.710 67.773 to 120.0 0.0 18.651 1.174 201__- 244_87 0.1333 0.0 21.361 2.848 Vel = 13.69 201 0.0 4.304 0.0 8.330 71.795 to 120.0 0.0 0.0 0.0 203 244.87 0.0139 0.0 - 8.330 0.116 Vel = 5.40_ 203 244.73 4.304 0.0 8.330 71.911 to 120.0 0.0 0.0 0.0 2_05 489._6 0.049_8_ 0.0 8.330 _ 0.415 Vel =_10_.8.0_ 205 246.45 4.304 0.0 8.330 72.326 to 120.0 0.0 0.0 0.0 207 736.05 0.1061 0.0 8.330 0.884 Vel = 16.23 207 62.50 4.304 0.0 8.330 73.210 to 120.0 0.0 0.0 0.0 209 673.55 0.0899 0.0 8.330 0.749 Vel = 14.85 209 56.11 4.304 0.0 8.330 73.959 to 120.0 0.0 0.0 0.0 211 617.44 0.0766 0.0 8.330 0.638 Vel = 13.62 211 50.64 4.304 0.0 8.330 74.597 to 120.0 0.0 0.0 0.0 213 566.8 0.0654 0.0 8.330 0.545 Vel = 12.50 213 46.11 4.304 0.0 8.330 75.142 to 120.0 0.0 0.0 0.0 215 520.69 0.0559 - 0.0 _- 8.330 0.466 Vel = 11.48 215 42.56 4.304 0.0 8.330 75.608 to 120.0 0.0 0.0 0.0 217 478.13 0.0477 0.0 8.330 0.397 Vel = 10.54 217 40.00 4.304 0.0 8.330 76.005 to 120.0 0.0 0.0 0.0 219 438.13 0.0407 0.0 8.330 0.339 Vel = 9.66 219 38.48 4.304 0.0 8.330 76.344 0 120.0 0.0 0.0 0.0 221 399.65 0.0342 0.0 8.330 0.285 Vel = 8.81 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 11 2010771 - B1S4RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 221 38.02 4.304 0.0 8.330 76.629 to 120.0 0.0 0.0 0.0 223 361.63 0.0285 0.0 8.330 0.237 Vel = 7.97 223 38.54 4.304 0.0 8.330 76.866 to 120.0 0.0 0.0 0.0 225 323.09 0.0232 0.0 8.330 0.193 Vel = 7.12 225 40.00 4.304 0.0 8.330 77.059 to 120.0 0.0 0.0 0.0 227 283.09 0.0181 0.0 8.330 0.151 Vel = 6.24 227 42.29 4.304 0.0 8.330 77.210 to 120.0 0.0 0.0 0.0 229 240.8 _ 0.0133_ 0.0 8.330 0.111 Vel = 5.3.1 229 45.28 4.304 0.0 8.330 77.321 to 120.0 0.0 0.0 0.0 231, _ 195.52 0.0091_ 0.0 8.330 0.0_76 ; Vel_ =_ 4.31 231 48.84 4.304 0.0 8.330 77.397 I _ to 120.0 0.0 0.0 0.0 233 146.68 0.0054 0.0 8.330 0.045 Vel = 3.23 233 52.87 4.304 0.0 8.330 77.442 to 120.0 0.0 0.0 0.0 235 93.81 0.0024 0.0 8.330 0.020 Vel = 2.07 235 0.0 2.703 T 18.651 2.710 77.462 to 120.0 0.0 18.651 1.174 234 93.81 0.0226 0.0 21.361 0.483 Vel_= 5.25 234 0.0 2.703 2X 33.571 167.750 76.771 to 120.0 0.0 33.571 0.723 134 93.81 0.0226 0.0 201.321 4.550 - Vel = 5.25 134 0.0 2.703 T 18.651 29.450 80.598 to 120.0 0.0 18.651 1.901 135 93.81 0.0226 0.0 48.101 1.088 5.25 0.0 Vel 93.81 83.587 K Factor= 10.26 NEW PATH 203 244.73 2.703 T 18.651 2.710 71.911 to 120.0 0.0 18.651 1.174 202 244.73 0.1332 0.0 21.361 2.846 Vel = 13.68 202 0.0 2.703 X 16.786 84.740 67.891 to 120.0 0.0 16.786 1.529 H5 _- 244.73_ 0_1332 0.0 101.526_ 13.528 _ _ Vel = 1_3.68 H5 122.11 2.703 0.0 10.000 52.834 K Factor = 16.80 to 120.0 0.0 0.0 0.178 H6 122.62 0.0370 0.0 10.000 0.370 Vel = 6.86 H6 121.48 2.703 0.0 10.000 52.286 K Factor 16.80 to 120.0 0.0 0.0 0.152 H7 1.14 0.0 0.0 10.000 0.0 Vel = 0.06 H7 121.30 2.703 0.0 10.000 52.134 K Factor 16.80 0 120.0 0.0 0.0 0.178 H8 120.16 0.0357 0.0 10.000 0.357 Vel = 6.72 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 12 2010771 - B1S4RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ••""• Notes '•"" Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H8 121.93 2.703 X 16.786 94.650 52.669 K Factor = 16.80 to 120.0 0.0 16.786 1.706 102 242.09 0.1306 0.0 111.436 14.553 Vel = 13.54 102 0.0 2:703 T 18.651 29.450 68.928 to 207 120.0 2.703 0.0 18.651 1.152 73.210 103 242.09 0.1306 0.0 48.101 6.281 Vel = 13.54 1.174 0.0 206 62.5 0.0107 0.0 . 21.361 242.09 Vel = 3.49 206 0.0 76.361 K Factor= 27.70 NEW PATH 209.420 72.264 to 205 246.45 2.703 T 18.651 2.710 72.326 106 to 0.0107 120.0 0.0 0.0 18.651 1.174 3.49 204 246.45 0.1350 T 0.0 _ 21.361 2.883 Vel = 13.78 204 0.0 2.703 X 16.786 84.740 68.269 1.152 to 120.0 62.5 0.0 16.786 1.529 48.101 H9, 246.45 0.13_50 ,, , 0.0 101..526 _ 13.7_03 Vel = 13.78 H9 122.35 2.703 0.0 10.000 53.037 K Factor = 16.80 to 120.0 K Factor = 7.14 0.0 0.0 0.178 H10 124.1_ 0.0379 _ _ 0.0 10.000 0.3_79 Vel = 6.94_ H10 121.70 2.703 73.959 0.0 10.000 52.480 K Factor = 16.80 to 120.0 18.651 0.0 0.0 0.152 208 H11 2.4 _ 0.0 0.0 0.0_---l-0.000 0.0 _ Vel = 0.13_ H11 121.53 2.703 0.0 10.000 52.328 K Factor = 16.80 to 120.0 0.0 0.0 0.178 H12 119_13 0.0352 0.0 10.000 0.352 _ _ _ Vel = 6.66 H12 122.14 2.703 X 16.786 94.650 52.858 K Factor = 16.80 to 120.0 0.0 16.786 1.706 104 241.27 0.1298 0.0 111.436 14.462 Vel = 13.49 104 0.0 2.703 T 18.651 29.450 69.026 to 120.0 0.0 18.651 1.152 105 241.27 0.1298 0.0 48.101 6.243 Vel = 13.49 0.0 241.27 76.421 K Factor= 27.60 NEW PATH 207 62.50 2.703 T 18.651 2.710 73.210 to 120.0 0.0 18.651 1.174 206 62.5 0.0107 0.0 . 21.361 0:228 Vel = 3.49 206 0.0 2.703 2X 33.571 209.420 72.264 to 120.0 0.0 33.571 0.026 106 62.5 0.0107 0.0 242.991 2.591 Vel = 3.49 106 0.0 2.703 T 18.651 29.450 74.881 to 120.0 0.0 18.651 1.152 107 62.5 0.0107 0.0 48.101 0.513 Vel = 3.49 0.0 62.50 76.546 K Factor = 7.14 NEW PATH 209 56.11 2.703 T 18.651 2.710 73.959 0 120.0 0.0 18.651 1.174 208 56.11 0.0088 0.0 21.361 0.187 Vel = 3.14 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 13 2010771 - B1S4RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv "•"•' Notes "•'•' Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 208 0.0 2.703 - 2X 33.571 209.420 72.972 -- to 120.0 0.0 33.571 0.026 108 56.11 0.0087 0.0 242.991 2.123 Vel = 3.14 108 0.0 2.703 T 18.651 29.450 75.121 to 120.0 0.0 18.651 1.152 109 56.11 0.0087 0.0 48.101 0.420 Vel = 3.14 0.0 56.11 76.693 K Factor = 6.41 NEW PATH 211 50.64 2.703 T 18.651 2.710 74.597 to 120.0 0.0 18.651 1.174 210_ 50.64 0.0073 - 0.0 _ 21.361 0.155 _-_ Vel =_ 2.83---- 83- 210 210 0.0 2.703 2X 33.571 209.420 73.578 to 120.0 0.0 33.571 0.026 110 50.64 0.0072_ _ 0.0 242.991,,,- 1.756 Vel =2_.83 110 0.0 2.703 T 18.651 29.450 75.360 to 120.0 0.0 18.651 1.152 111 50.64 0.0072 0.0- 48.101 0.347 Vel = 2.83 0.0 5.0.64 76._859 - K Factor= 5.78 NEW PATH 213 46.11 2.703 T 18.651 2.710 75.142 to 120.0 0.0 18.651 1.174 212 46.11 0.0061 0.0 21.361 0.130 Vel = 2.58 212 0.0 2.703 2X 33.571 209.420 74.098 to 120.0 0.0 33.571 0.026 112 46.11 0.0061 0.0 242.991 1.476 Vel = 2.58 112 0.0 2.703 T 18.651 29.450 75.600 to 120.0 0.0 18.651 1.152 113 46.11 0.0061 0.0 48.101 0.293 Vel = 2.58 0.0 46.11 77.045 K Factor = 5.25 NEW PATH 215 42.55 2.703 T 18.651 2.710 75.608 to 120.0 0.0 18.651 1.174 214 42.55 0.0052 0.0 21.361 0.112 Vel = 2.38 214 0.0 2.703 2X 33.571 209.420 74.546 to 120.0 0.0 33.571 0.026 114 42.55 0.0052 0.0 242.991 1.272 Vel = 2.38 114 0.0 2.703 T 18.651 29.450 75.844 to 120.0 0.0 18.651 1.152 115 42.55 0.0052 0.0 48.101 0.252 Vel = 2.38 0.0 42.55 77.248 K Factor= 4.84 NEW PATH 217 40.00 2.703 T 18.651 2.710 76.005 0 120.0 0.0 18.651 1.174 216 40.0 0.0047 0.0 21.361 0.100 Vel = 2.24 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 14 2010771 - B1S4RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ***'*" Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 216 0.0 2.703 2X 33.571 209.420 74.931 to Vel = 120.0 0.0 33.571 0.026 116 40.0 0.0047 0.0 242.991 1.135 Vel = 2.24 116 0.0 2.703 T 18.651 29.450 76.092 to Vel = 120.0 0.0 18.651 1.152 117 40.0 0.0047 0.0 48.101 0.225 Vel = 2.24 to 0.0 120.0 T 0.0 33.571 0.026 40.00 118 ,, ; 38.49 77.469 K Factor= 4.54 NEW PATH 0.0 242!991 1.057.--.-,,,,, 2_._1.5., d 219 38.49 2.703 T 18.651 2.710 76.344 Vel = 2.15 to 0.0 120.0 2X 0.0 18.651 1.174 218 38.49 0.0044 _ 0.0 _ 21.361 0.093 Vel = 2.15 218 0.0 2.703 2X 33.571 209.420 75.263 2.15 to 0.0 120.0 T 0.0 33.571 0.026 118 ,, ; 38.49 0.0043, -;i. 0.0 242!991 1.057.--.-,,,,, 2_._1.5., d 118 0.0 2.703 T 18.651 29.450 76.346 Vel ..= to 0.0 120.0 0.0 18.651 1.152 119 38.49 0.0043 0.0 48.101 0.209 Vel = 2.15 0.0 225 38.49 77.707 _ K Factor= 4.37_ NEW PATH___ 120.0 0.0 18.651 1.174 221 38.01 2.703 T 18.651 2.710 76.629 Vel = 2.24 to 120.0 0.0 18.651 1.174 220 38.01 0.0043 0.0 21.361 0.091 Vel = 2.13 220 0.0 2.703 2X 33.571 209.420 75.546 to 120.0 0.0 33.571 0.026 120 38.01 0.0043 0.0 242.991 1.033 Vel = 2.13 120 0.0 2.703 T 18.651 29.450 76.605 to 120.0 0.0 18.651 1.152 121 38.01 0.0042 0.0 48.101 0.204 Vel = 2.13 0.0 38.01 77.961 K Factor= 4.30 NEW PATH 223 to 222 38.54 38.54 2.703 120.0 0.0044 T 18.651 0.0 6.0 2.710 18.651 21.361 76.866 1.174 0:094 Vel = 2.15 222 0.0 2.703 2X 33.571 209.420 75.786 to 120.0 0.0 33.571 0.026 122 38.54 0.0044 0.0 242.991 1.059 Vel = 2.15 122 0.0 2.703 T 18.651 29.450 76.871 to 120.0 0.0 18.651 1.152 123 38.54 0.0044 0.0 48.101 0.210 Vel = 2.15 0.0 38.54 78.233 K Factor= 4.36 NEW PATH 225 40.00 2.703 T 18.651 2.710 77.059 to 120.0 0.0 18.651 1.174 224 40.0 0.0047 0.0 21.361 0.100 Vel = 2.24 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 15 2010771 - B1S4RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ***"'• Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 224 0.0 2.703 2X 33.571 209.420 75.985 to 48.84 120.0 0.0 33.571 0.026 124 40.0 0.0047 0.0 242.991 1.135 Vel = 2.24 124 0.0 2.703 T 18.651 29.450 77.146 to Vel = 120.0 0.0 18.651 1.152 125 40.0 0.0047 0.0 48.101 0.225 Vel = 2.24 to 0.0 120.0 0.0 33.571 0.026 40.00 126 42.29 78.523 K Factor = 4.51 NEW PATH 227 42.29 2.703 T 18.651 2.710 77.210 48.84 0.0068_ to 0.0 120.0 to 0.0 18.651 1.174 48.84 0.0068 226 42.29 0.0051 0.0 21.361 0.110 Vel = 2.36 226 0.0 2.703 2X 33.571 209.420 76.146 52.87 0.0079 to 120.0 0.0 33.571 0.026 126 42.29 0.0052 0.0 242.99.1; } 1.258 d Vel = 2.36 "d 126 0.0 2.703 T 18.651 29.450 77.430 to 120.0 0.0 18.651 1.152 127 42.29 0.0052 --- 0.0 48.101 0.249 Vel = 2.36 0.0 42.29 78.831 K Factor= 4.76 NEW PATH 229 45.28 2.703 T 18.651 2.710 77.321 to 120.0 0.0 18.651 1.174 228 _ 45.28 0.0059 0.0 21.361 0.126 - Vel = 2.53 228 0.0 2.703 2X 33.571 209.420 76.273 to 120.0 0.0 33.571 0.026 128 45.28 0.0059 0.0 242.991 1.427 Vel = 2.53 128 0.0 2.703 T 18.651 29.450 77.726 to 120.0 0.0 18.651 1.152 129 45.28 0.0059 0.0 48.101 0.283 Vel = 2.53 0.0 45.28 79.161 K Factor = 5.09 NEW PATH 231 48.84 2.703 T 18.651 2.710 77.397 to 120.0 0.0 18.651 -1.174 230 48.84 0.0068 0.0 21.361 0.146- Vel = '233 230 0.0 2.703 to 33.571120.0 130 48.84 0.0068_ 130 0.0 2.703 to 18.651120.0 131 48.84 0.0068 0.0 48.8.4 NEW PATH 233 52.87 2.703 0 120.0 232 52.87 0.0079 2X 33.571 209.420 76.368 0.0 33.571 0.026 0.0 2.42.9_91 1.6_42 Vel = 2_.73 T 18.651 29.450 78.036 0.0 18.651 1.152 0.0 48.101 0.325 Vel = 2.73 79.513 K Factor = 5.48 T 18.651 2.710 77.442 -- --- ------ - 0.0 18.651 -1.174 0.0 21.361 0.168 Vel = 2.96 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 16 2010771 - B1S4RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv Notes '•"" Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 209.4202320.0 2.703 2X 33.571 76.436 to 120.0 0.0 33.571 0.026 132 52.87 0.0078 0.0 242.991 1.901 Vel = 2.96 132 0.0 2.703 T 18.651 29.450 78.363 to 120.0 0.0 18.651 1.152 133 52.87 0.0078 0.0 48.101 0.377 Vel = 2.96 0.0 52.87 79.892 K Factor= 5.92 Computer Programs by Hydratec Inc. Revision: 50.52.1 AutoPeaking Summary Wiginton Fire Systems 2010771 - B1S4RA1 Auto Peaking Summary - List of Pipes for Area Calculated Left Right Side Side From To Length From To Length Page 17 Date 5-19-17 H4 100 94.650 H1 200 84.740 H8 102 94.650 202 H5 84.740 H12 104 94.650 204 H9 84.740 H4 100 94.650 H1 200 84.740 H8 102' 94.650 202 H5 184.740 H12 104 94.650 204 H9 84.740 Flow Safety Pressure Required Margin Differential Left 10.000 1 1710.707 17.642 0.036 Area Calculated 1 1710.737 17.606 0.000 Right 10.000 1710.811 17.681 0.075 Typical Distance Between Heads = 10.000 Split Point Used in Worst Area Peaked = H3 Split Point Used in Area Calculated = H3 Computer Programs by Hydratec Inc. Revision: 50.52.1 M 0g)'D 90 R (D M FIRE SYSTEMS Wiginton Fire Systems 699 Aero Lane Sanford, FL 32771 407-585-3200 Job Name 2010771 - 61S5RA1' Drawing FP9 Location BUILDING ONE Remote Area B1S5RA1 Contract 2010771 Data File 2010771 - B1S5RA1.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 W Wiginton Fire Systems 2010771 - B 1 S5RA1 Project name: GANESH NORTH Location: BUILDING ONE Drawing no: FP9 Date: 5-19-17 Design HYDRAULIC CALCULATIONS for Remote area number. B1S5RA1 Remote area location: SYSTEM FIVE Occupancy classification: HIGH PILED STORAGE Density: .37 - Gpm/SgFt Area of application: 2,044 - Sq Ft Coverage per sprinkler: 100 MAX - SgFt Type of sprinklers calculated. 11.2K STANDARD RESPONSE UPRIGHT No. of sprinklers calculated. 22 In -rack demand: N/A - GPM Hose streams: 500 - GPM Total water required (including hose streams): 1394.581 - GPM @ Type of system: WET Volume of'dry or preaction system:' N/A - Gal Water supply information Date: 8-2-16 Location: ALONG W. 1ST STREET Source: WFS Name of contractor. WIGINTON FIRE SYSTEMS Address: 699 AERO LANE, SANFORD, FL 32771 Phone number: 407-585-3200 Name of designer: W. AMMONS Authority having jurisdiction: CITY OF SANFORD Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Revision: 50.52.1 41.223 - Psi Page 1 Date 5-19-17 Water )ly Curve C Wiginton Fire Systems = Page 2 2010771 - BIS5RA1 Date 5-19-17 City Water Supply: C1 - Static Pressure 60 C2 - Residual Pressure: 50 C2 - Residual Flow 1840 City Water Adjusted to Pump Inlet for Pf - Elev - Hose Flow P3 - Pump Pressure @ Max Flow Al - Adjusted Static: 52.437 A2 - Adj Resid 25.858 @ 1261.31 A3 - Adj Resid 1.391 @ 1881.1 210 196 182 p 168 R 154 E 140 S 126 S 112 U 98 R 84 E 70 56 42 28 14 Pump Data: P1 - Pump Churn Pressure 126.18 P2 - Pump Rated Pressure 109.95 P2 - Pump Rated Flow 1261.31 P3 - Pump Pressure @ Max Flow 79.39 P3 - Pump Max Flow 1881.1 City Residual Flow @ 0 4846.63 City Residual Flow @ 20 3892.74 City Water @ 150% of Pump 49.58 Demand: D1 - Elevation 11.503 D2 - System Flow 894.58 D2 - System Pressure 142.838 Hose ( Demand ) D3 - System Demand 894.58 Hose ( Adj City) 500 Safety Margin 12.789 200 400 600 800 1000 1200 1400 1600 1800 FLOW N^1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Diagram Wiginton Fire Systems 2010771 - B1S5RA1 Page 3 Date 5-19-17 38.31132 154.4 309.3 475.8 542.4 627.2 739.5 894.6 894.6 894.6H54- H6 4- H7 +- H8 _ 100 101 +- 103 105 - 107 109 111 113 +- 115 117 +- 119 +- 121 +- 125 +- 127 129 131 +- TR5+- BR5+- PO75154.4 154.4 445.8 507.5 5819 679.5 808.4 894.6 894.6 894.6 894.6 1394.6 1394.6 Pl « SPIG- UG3 UG44- UGSi UG6e- TEST 894.6 1394.6 1394.6 1.9 72.1 153.5 153.5 448.8 387 312.7 215.1 86.2 86.2 86.2H5 -+ H4 H3 +- H2 +- H1 +- 200 F 201 203 +- 205 r- 207 209 +- 211 +- 213 F 215 t 217 F 219 221 +- 223 4- 222 122 123 F- 125 34.8 111.1 153.5 307.5 418.7 352.2 267.3 155 86.2 86.2 154 111.5 34.9 38.4 113.5 154.9 203 -+ 202- H9 -* H10 -a H11- H12+- H134- H14r. H15r- H16+- 1024- 103 T 154 72.3 1.9 75.2 154.9 1 307.5 1 141.3 92.9 1.4 89.2 136.4 205-i 204- H17 H18- H19 -i H2O+- H214- H224- 1044_ 105 1 141.3 46.7 43.7 136.4 I 448.8 1 30.1 30.1 2074 206+- 106+- 107 t 30.1 1 1 418.7 1 475.8 1 31.7 31J 209 4 208 4 108 4- 109 t 31.7 1 I 387 1 507.5 1 34.9 34.V 211 +- 210 4- 110 4- 111 i34.9 ? 352.2 1 542.4 1 39.5 39.5 2134- 2124 1124- 113 1 39.5 1 I 312.7 1 581.9 1 45.3 45.1 215+- 214+- 114- 115 1 45.3 1 267.3 1 627.2 1 522 52.g 2174_ 216-. 116 117 1 52.2 1 1 215.1 1 679.5 1 601 60.1 2194- 2184- 1184- 119 60.1 1 155 1 739.5 1 68.9 68.0 221+- 220 4 120 4- 121 68.9 Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings 3d Summary Wiginton Fire Systems Page 4 2010771 - B1S51RA1 Date 5-19-17 Fitting Legend Abbrev. Name '/: _ % 1 1'/. 1'/: 2 2'/: 3 3'/: 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0E90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61GGenericGateValve00000111122345678101113J90'Tee-Branch Gry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 '= 21 25 33 41 50 65 78 88 98 120LLongTumElbow1122234556891316182427303440SGenericSwingCheckValve4557911141619222732455565768798109130T90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121V90'Ell Firelock #001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0ZafAmes3000SSFittinggeneratesaFixedLossBasedonFlow Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD Wiginton Fire Systems Page 5 2010771 B1S5RA1 Date 5-19-17 Node Elevation K -Fact Pt Pn Flow Density Area PressNo-. Actual Actual Req. H5 28.56 11.2 10.59 na 36.45 0.37 98.5 7.0H628.88 11.2 10.74 na 36.7 0.37 98.5 7.0H729.19 11.2 11.59 na 38.13 0.37 98.5 7.0H829.5 11.2 13.58 na 41.27 0.37 98.5 7.010027.833 27.89 na 101 27.833 48.36 na 103 27.833 48.62 na 105 27.833 49.58 na 107 27.833 51.46 na 109 27.833 53.59 na 111 27.833 55.98 na 113 27.833 58.69 na 115 27.833 61.77 na 117 27.833 65.32 na 119 27.833 69.42 na 121 27.833 74.23 na 125 27.833 85.01 na 127 31.292 96.18 na 129 31.292 117.2 na 131 29.167 127.28 na TR5 29.167 128.86 na BR5. 2.0 142.39 na Po". 2.0 142,84 na PI 2.0 37.75 na SPIG 3.0 40.21 na UG3 3.0 41.54 na 500.0 UG4 3.0 49.24 na UG5 3.0 52.75 na UG6 3.0 55.35 na TEST 2.0 54.01 na 14 28.25 11.2 10.72 na 36.67 0.37 98.5 7.0H327.94 11.2 11.1 na 37.31 0.37 98.5 7.0H227.63 11.2 12.15 na 39.04 0.37 98.5 7.0H127.31 11.2 14.34 na 42.41 0.37 98.5 7.020026.18 37.72 na 201 23.47 45.85 na 203 23.47 46.11 na 205 23.47 47.06 na 207 23.47 48.97 na 209 23.47 50.64 na 211 23.47 52.09 na 213 23.47 53.31 na 215 23.47 54.29 na 217 23.47 55.02 na 219 23.47 55.51 na 221 23.47 55.78 na 223 23.47 55.86 na 222 26.18 57.08 na 122 30.47 76.68 na 123 27.833 84.78 na 202 26.18 37.94 na H9 27.31 11.2 14.42 na 42.53 0.37 98.5 7.0H1027.63 11.2 12.22 na 39.16 0.37 98.5 7.0H1127.94 11.2 11.16 na 37.42 0.37 98.5 7.0H1228.25 11.2 10.79 na 36.78 0.37 98.5 7.0H1328.56 11.2 10.65 na 36.56 0.37 98.5 7.0H1428.88 11.2 10.8 na 36.81 0.37 98.5 7.0H1529.19 11.2 11.66 na 38.25 0.37 98.5 7.0H1629.5 11.2 13.66 na 41.4 0.37 98.5 7.010230.47 26.9 na 204 26.18 39.92 na H17 27.42 11.2 18.65 na 48.37 0.37 98.5 7.0 Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - Standard Wiginton Fire Systems Page 6 2010771 - B1S5RA1 Date 5-19-17 Node Elevation K -Fact Pt Pn Flow Density Area Press No. - --- Actual- - Actual Req._ H18 27.75 11.2 16.96 na 46.13 0.37 98.5 7.0 H19 28.08 11.2 16.39 na 45.34 0.37 98.5 7.0 H2O 28.41 11.2 16.24 na 45.14 0.37 98.5 7.0 H21 28.73 11.2 16.49 na 45.48 0.37 98.5 7.0 H22 29.06 11.2 17.78 na 47.23 0.37 98.5 7.0 104 30.47 32.17 na 206 26.18 48.13 na 106 30.47 49.33 na 208 26.18 49.84 na 108 30.47 51.36 na 210 26.18 51.37 na 110 30.47 53.54 na 212 26.18 52.7 na 112 30.47 55.91 na 214 26.18 53.84 na 114 30.47 58.51 na 216 26.18 54.79 na 116 30.47 61.42 na 218 26.18 55.56 na 118 30.47 64.71 na 220 26.18 56.18 na 120 30.47 68.49 na The maximum velocity is 30.14 and it occurs in the pipe between nodes 121 and 125 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 7 2010771 - B1S5RA1 Date 5-19-17 Hyd, Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ••**••• Notes *`••`* Point Qt Pf/Ft Eqv. Ln. Total Pf Pn EQUIVALENT K'S REMOTE HEAD TO SUPPLY - - - H5 38.34 1.728 0.0 7.500 10.589 K Factor = 11.20 to. 120.0 0.0 0.0 -0.139 H6 38.34 0.0381 0.0 7.500 0.286 Vel = 5-25 H6 36.70 1.728 0.0 7.500 10.736 K Factor = 11.20 to 120.0 0.0 0.0 -0.134 H7 75.04 0.1321 0.0 7.500 0.991 Vel = 10 27 H7 38.14 1.728 0.0 7.500 11.593 K Factor = 11.20 to 39.50 120.0 0.0 0.0 0.134 H8 113.18 0.2827 0.0 7.500 2.120 Vel = 15.48 H8 41.27 1.728 J 11.29 15.760 13.579 K Factor = 11.20 to 45.32 120.0 0.0 11.290 0.722 100 154.45_ 0.502_4 0.0 27.050 - 13.590_ Vel = 21.13 100 d 0.0 1.728 r T 11.29 29.450 27.891to Vel = 23.39 117 52.21 120.0 0.0 11.290 0.0 101 154.45 0.5024 0.0 40.740 20.468 Vel = 21.13 101 0.0 3.31 0.0 12.500 48.359 Vel = 25.33 to 60.10 120.0 0.0 0.0 0.0 103 - 154.45 0.0212 0.0 - 12.5_00 0_.265 48.624 Vel = 5.76 103 154.89 3.31 0.0 12.500 to 68.86 120.0 0.0 0.0 0.0 10_5 309.34 0.0766 0.0 12.500 0.958 Vel =_ 11._53 105 136.44 3.31- 0.0 12.500 49.582 Vel = 30.14 to 120.0 0.0 0.0 0.0 107 445.78 0.1506 0.0 12.500 -- --- 1.883 Vel = 16.62 107 30.07 3.31 0.0 12.500 51.465 to 120.0 0.0 0.0 0.0 109 475.85 0.1700 0.0 12.500 2.125 Vel = 17.74_ 109 31.68 3.31 0.0 12.500 53.590 to 120.0 0.0 0.0 0.0 111 507.53 0.1915 0.0 12.500 2.394 Vel = 1R-92 111 to 113 34.89 542.42 3.31 120.0 0.2166 0.0 0.0 0.0 12.500 0.0 12.500 55.984 0.0 2.707 Vel = 20.22 1.13 39.50 3.31 0.0 12.500 58.691 to 120.0 0.0 0.0 0.0 115 581.92 0.2466 0.0 12.500 3.083 Vel = 21.70 115 45.32 3.31 0.0 12.500 61.774 to 120.0 0.0 0.0 0.0 117 627.24 0.2834 0.0 12.500 3.542 Vel = 23.39 117 52.21 3.31 0.0 12.500 65.316 to 120.0 0.0 0.0 0.0 119 679.45 0.3286 0.0 12.500 4.107 Vel = 25.33 119 60.10 3.31 0.0 12.500 69.423 to 120.0 0.0 0.0 0.0 121 739.55 0.3843 0.0 12.500 4.804 Vel = 27.57 121 68.86 3.31 T 21.71 2.080 74.227 to 120.0 0.0 21.710 0.0 125 808.41 0.4531 0.0 23.790 10.779 Vel = 30.14 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 8 2010771 - B1S5RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 125 86.17 4.304 0.0 83.330 85.006 to 120.0 0.0 0.0 1.498 127 894.58 0.1521 0.0 83.330 12.677 Vel = 19.73 127 0.0 4.304 2V 18.826 119.330 96.185 to 120.0 0.0 18.826 0.0 129 894.58 0.1521 0.0 138.156 21.016 Vel = 19.73 129 0.0 4.304 V 9.413 50.790 117.201 to 120.0 0.0 9.413 0.920 131 894.58 0.1521 0.0 60.203 9.159 Vel = 19.73 131 0.0 4.304 V 9.413 1.000 127.280 to 120.0 0.0 9.413 0.0 TR5 - 894.58 0.1521 __ 0.0 10.413 _ 1.584 Vel = 19.73 TR5 0.0 6.357 T 37.72 27.167 128.864 to 120.0 B 12.573 50.293 11.766 BRS l_ _ 894.58 0.0228 _ 0.0 77.460 1.763 ,, _ _ Vel = 9.04 - BR5 0.0 8.249 B 13.345 6.000 142.393 to 120.0 S 50.044 63.389 0.0 PO 894.58 0.0064_ 0.0 69.389 0.445 Vel = 5.37 0.0 894.58 _ 142.838_ _ Factor= 74.85 System Demand Pressure 142.838 K Safety Margin 12.789 Continuation Pressure 155.627 Pressure @ Pump Outlet 155.627 Pressure From Pump Curve 117.880 Pressure @Pump Inlet PI 0.0 8.249 T 38.923 2.500 37.747 37.747 to 120.0 G 4.448 43.371 2.166 SPIG 894.58 0.0_064 0.0 45.871 0.294 Vel = SPIG 0.0 8.27 E 26.955 195.000 40.207 5.37__ to 140.0 T 52.413 85.358 0.0 UG3 894.58 0.0048 G 5.99 280.358 1.332 Vel = 5.34 UG3 500.00 8.27 T 52.413 300.000 41.539 Qa = 500 to 140.0 Zaf 0.0 130.283 3.053 Fixed Loss = 3.053 UG4 1394.58 0.0108 4L 77.87 430.283 4.651 Vel = 8.33 UG4 0.0 • 10.28 T 71.092 865.000 49.243 to 140.0 0.0 71.092 0.0 UG5 1394.58 0.0037 0.0 936.092 3.507 Vel = 5.39 UG5 0.0 12.34 T 88.164 1600.000 52.750 to 140.0 0.0 88.164 0.0 UG6 1394.58 0.0015 0.0 1688.164 2.599 Vel = 3.74 UG6 0.0 12.34 T 88.164 450.000 55.349 to 140.0 0.0 88.164 2.166 TEST 1394.58 0.0015 0.0 538.164 0.829 Vel = 3.74 0.0 1394.58 54.012 K Factor = 189.76 NEW PATH Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 92010771 - B1S5RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ""••` Notes '••`•• Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H5 1.90 1.728 0.0 7.500 10.589 to to 120.0 0.0 0.0 0.134 0.0 H4 1.9 0.0001 0.0 7.500 0.001 Vel = 0.26 H4 36.68 1.728 0.0 . 7.500 10.722 K Factor = 11.20to 52.093 120.0 0.0 0.0 0.134 120.0 H3 34.78 0.0319 0.0 7.500 0.239 Vel = 4.76 H3 37.30 1.728 0.0 7.500 11.095 K Factor = 11.20to 3.31 120.0 0.0 0.0 0.134 H2 72.08 0.1227 0.0 7.500 0.920 Vel = 9.86 H2 39.04 1.728 0.0 7.500 12.149 K Factor = 11.20to 11.66 120.0 0.0 0.0 0.139 12.500 H1 111.12 0.2732 0.0 7.500 2.049 Vel = 15.20 H1 42.41 1.728 J 11.29 34.780 14.337 K Factor = 11.20to 2,500 120.0 0.0 11.290 0.489 52.22 200 153.53 0.4969 0.0 46.070 22.893 Vel 21.00 200 0.0 1.728 T 11.29 2.710 37.719 to 215.13 120.0 0.0 11.290 1.174 Vel = 201_ 153.53 0.4969 _ 0.0 14.000 6.956 Vel = 21.00 201 0.0 3.31 0.0 12.500 45.849 ---- to 120.0 0.0 0.0 0.0 0.0 203 153.53 0.0210 0.0 - 12.500 _ 0.262 Vel_ =_ 5.72 203 154.02 3.31 0.0 12.500 46.111 to 120.0 0.0 0.0 0.0 205 307.55 0.0758 0.0 12.500 0.948 Vel = 11.47 205 141.25 3.31 0.0 12.500 47.059 to 120.0 0.0 0.0 0.0 207 448.8 0.1526 0.0 12.500 1.907 Vel = 16.7_3_ 207 30.07 3.31 0.0 12.500 48.966 to 120.0 0.0 0.0 0.0 209 418.73 0.1342 0.0 12.500 1.677 Vol = 1 r, a1 209 31.68 3.31 0.0 12.500 50.643 to 120.0 0.0 0.0 0.0 211 387.05 0.1160 0.0 12.500 1.450 Vel = 14.43 211 34.89 3.31 0.0 12.500 52.093 to 120.0 0.0 0.0 0.0 213 352.16 0.0974 0.0 12.500 1.217 Vel = 13.13 213 39.50 3.31 0.0 ' 12.500 53.310 to 120.0 0.0 0.0 0.0 215 312.66 0.0782 0.0 12.500 0.977 Vel = 11.66 215 45.31 3.31 0.0 12.500 54.287 to 120.0 0.0 0.0 0.0 217 267.35 0.0585 0.0 -1 2,500 0.731 Vel = 9.97 217 52.22 3.31 0.0 1.500 55.018 to 120.0 0.0 0.0 0.0 219 215.13 0.0392_ 0.0 12.500 0.490 Vel = 8.02 219 60.10 3.31 0.0 12.500 55.508 to 120.0 0.0 0.0 0.0 221 155.03 0.0214 0.0 12.500 0.267 Vel = 5.78 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 102010771 - B1S5RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv •"'•" NotesPointQtPf/Ft Eqv. Ln. Total Pf Pn 221 68.86 3.31 0.0 12.500 - 55.775 - - - - - - -- - to 120.0 0.0 0.0 0.0 223 86.17 0.0072 0.0 12.500 0.090 Vel = 3-21 223 0.0 1.728 T 11.29 2.710 55.865 to 86.17 to 0.0 120.0 85.006 0.0 11.290 1.174 0.0001 0.0 222 86.17 0.1707 154.02 0.0 14.000 2.390 Vet = 11.79 222 0.0 1.728 2J 22.58 103.110 57.081 202 _ 154.02 to 0.0 120.0 6.997 0.0 22.580 1.858 1.728 J 11.29 122 86.17 0.1707 to 0.0 125.690 21.455 Vel = 11.79 122 0.0 1.728 J 11.29 29.450 76.678 Vel = 21.07 H9 to 1.728 120.0 7.500 0.0 11.290 1.142 to 120.0 123 86.17 0.1707 0.134 0.0 _ _ 40.740 6.955 Vel = 11.79_ 123 0.0 3.31 T 21.71 10.420 84.775 Vel = 15.25 to 39.15 120.0 0.0 0.0 21.710 0.0 to 102 125 86-17 0.0072 l 0.0 A2.130,,-_ 0.231 Vel = 3.21 7.500 0.926 Vel = 9.90 H11 37.42 1.728 0.0 7.500 11.162 H12 0.0 1.728 0.0 7.500 10.787 K Factor = 11.20to 86.17 120.0 0.0 0.0 85.006 K Factor = 9.35 NEW PATH 1.88 0.0001 0.0 0.001 203 154.02 1.728 T 11.29 2.710 46.111 to to 120.0 0.0 11.290 1.174 0.139 202 _ 154.02 0.4998_ 0.0 14.000 6.997 Vel 21.07 202 0.0 1.728 J 11.29 34.780 37.940 to to 120.0 0.0 11.290 0.489 0.134 H9 154.02 0.4998_ 0.0 4.6.070 23.028 Vel = 21.07 H9 42.54 1.728 0.0 7.500 14.423 K Factor = 11.20to to 120.0 0.0 0.0 0.139 0.134 H10 111.48 0.2749 0.0 7.500 7.500 2.131 H16 41.39 1.728 T 11.29 2.062 Vel = 15.25 H10 39.15 1.728 0.0 7.500 12.222 K Factor = 11.20to 102 120.0 0.0 0.0 0.134 13.662 H11 72.33 0.1235 0.0 7.500 0.926 Vel = 9.90 H11 37.42 1.728 0.0 7.500 11.162 K Factor = 11.20to120.0 0.0 0.0 0.134 H12 34.91 0.0321 0.0 7.500 0.241 Vel = 4.78 H12 36.79 1.728 0.0 7.500 10.787 K Factor = 11.20to120.0 0.0 0.0 0.134 H13 1.88 0.0001 0.0 7.500 0.001 Vel = • 0.26 H13 36.55 1.728 0.0 7.500 10.654 K Factor = 11.20to120.0 0.0 0.0 0.139 H14 38.43 0.0384 0.0 7.50_0 _ 0.2_88 Vel = H14 36.81 1.728 0.0 7.500 10.803 5.26 K Factor = 11.20to120.0 0.0 0.0 0.134 H15 75.24 0.1328 0.0 7.500 0.996 Vel = 10.29 H15 38.26 1.728 0.0 7.500 11.665 K Factor = 11.20to120.0 0.0 0.0 0.134 H16 113.5 0.2841 0.0 7.500 2.131 Vel = 15.53 H16 41.39 1.728 T 11.29 15.760 13.662 K Factor = 11.20 0 120.0 0.0 11.290 0.420 102 154.89 0.5051 0.0 27.050 13.662 Vel = 21.19 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 112010771 - B1S5RA1 Date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt PtRef. "C" or Ftng's Pe Pv '*""'• NotesPointQtPf/Ft Eqv. Ln. Total Pf pn 102 0.0 1.728 J 11.29 29.450 26.904 to 30.06 120.0 0.0 11.290 1.142 103 154.89 0.5051 0.0 40.740 20.578 Vel = 21.19 206 0.0 0.0243' 0.0 14.000 0.340 Vel = 4.11 206 154.89 1.728 2J 22.58 103.040 48.624 K Factor = 22.21 NEW PATH 120.0 0.0 22.580 1.858 205 141.25 1.728 T 11.29 2.710 47.059 3.058 to 106 120.0 0.0 11.290 1.174 49.332 204 141.25 0.4259 0.0 14.000 5.962 Vel = 19.32 204 0.0 1.728 J 11.29 37.390 39.923 0.991 to 120.0 0.0 11.290 0.537H17 ___-_141.25 0.4259_ 0.0 48.680 20.733_ Vel = 19.32 H17 to 48.37 1.728 0.0 7.880 18.653 K Factor = 11.20120.0 0.0 0.0 0.143H1892.88 0. 1961 0.0 7.880 1.545 Vel = 12.71 H18 to 46.13 1.728 0.0 7.880 16.965 K Factor = 11.20120.0 0.0 0.0 0.143H1946.75 0.0551 0.0 7.880 0.434 Vel = 6.40 H19 to 45.34 1.728 0.0 7.880 16.388 K Factor = 11.20120.0 0.0 0.0 0.143H2O1.41 to 1.728 0.0 7.880 16.245 K Factor = 11.20120.0 0.0 0.0 0.139H2143.73 0.0487 0.0 7.880 0.384 Vel = 5.98 H21 to 45.48 1.728 0.0 7.880 16.490 K Factor = 11.20120.0 0.0 0.0 0.143H22 _ 89.21 0.1820 0.0 7.88_0 1.434_Vel 12.20H22 to 47.23 1.728 J 11.29 26.250 17.781 - K Factor = 11.20 _ - 120.0 0.0 11.290 0.611104136.44 0.3995 _ 0.0 37.540_ 14.996 Vel = 18.67 104 0.0 1.728 T 11.29 29.450 32.166to120.0 0.0 11.290 1.142 105 136.44 0.3995 0.0 40.740 16.274 Vel = 18.67 0.0 136.44 49.582 K Factor= 19.38NEWPATH 207 30.06 1.728 T 11.29 2.710 48.966to120.0 0.0 11.290 1.174 206 30.06 0.0243' 0.0 14.000 0.340 Vel = 4.11 206 0.0 1.728 2J 22.58 103.040 48.132 to 120.0 0.0 22.580 1.85810630.06 0.0243 0.0 125.620 3.058 Vel = 4.11 106 0.0 1.728 T 11.29 29.450 49.332 to 120.0 0.0 11.290 1.142 107 30.06 0.0243 0.0 40.740 0.991 Vel = 4.11 0.0 30.06 51.465 K Factor= 4.19 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems 7r11n771 - R1_Qr,RA1 12 = R-10-17 109 31.69 0.0268 0.0 40.740 1.093 Vel - 4.34 0.0 31.69 53.590 K Factor = 4.33 NEW PATH 211 34.89 1.728 T 11.29 2.710 52.093 - to 120.0 0.0 11.290 1.174 Hyd. Qa Dia. Fitting Pipe Pt Pt 0.0 ------ Ref. 0.449 C" or Ftng's Pe Pv """" Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn to NEW PATH 120.0 0.0 209 31.69 1.728 T 11.29 2.710 50.643 4.026 to 120.0 0.0 11.290 1.174 11.29 208 31.69 0.0268 0.0 14.000 0.375 Vel = 4.34 208 0.0 1.728 2J 22.58 103.040 49.844 111 to 0.0321 120.0 0.0 22.580 1.858 Vel = 4.77 108 31.69 0.0268 0.0 125.620 3.369 Vel = 4.34 108 0.0 1.728 T 11.29 29.450 51.355 to 55.984 120.0 0.0 11.290 1.142 109 31.69 0.0268 0.0 40.740 1.093 Vel - 4.34 0.0 31.69 53.590 K Factor = 4.33 NEW PATH 211 34.89 1.728 T 11.29 2.710 52.093 - to 120.0 0.0 11.290 1.174 210 34.89 0.0321 0.0 ------ 14.000 0.449 Vel = 4.77 210 0.0 1.728 2J 22.58 103.040 51.368 to 120.0 0.0 22.580 1.858 110 0.0320' 0.0 125.620 4.026 Vel = 34.89 110 0.0 1.728 T 11.29 29.450 53.536 4.77 I 0 120.0 0.0 11.290 1.142 111 34.89 0.0321 0.0 40.740 1.306 Vel = 4.77 0.0 34.89 55.984 K Factor = 4.66 NEW PATH 213 39.49 1.728 T 11.29 2.710 53.310 to 120.0 0.0 11.290 1.174 212 39.49 0.0404 0.0 14.000 0.565 Vel = 5.40 212 0.0 1.728 2J 22.58 103.040 52.701 to 120.0 0.0 22.580 1.858 112 39.49 0.0403 0.0 125.620 5.064 Vel = 5.40 112 0.0 1.728 T 11.29 29.450 55.907 to 120.0 0.0 11.290 1.142 113 39.49 0.0403 0.0 40.740 1.642 Vel = 5.40 0.0 39.49 58.691 K Factor = 5.15 NEW PATH 215 45.32 1.728 T 11.29 2.710 54.287 to 120.0 0.0 11.290 1.174 214 45.32 0.0520 0.0 14.000 0.728 Vel = 6.20 214 0.0 1.728 2J 22.58 103.040 53.841 to 120.0 0.0 22.580 1.858 114 45.32_ 0.0520 0.0 125.620 6.531 Vel = 6.20 114 0.0 1.728 T 11.29 29.450 58.514 to 120.0 0.0 11.290 1.142 115 45.32 0.0520 0.0 40.740 2.118 Vel = 6.20 0.0 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Wiginton Fire Systems Page 13- 2010771 - B1S5RA1 date 5-19-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 45.32 NEW PATH 61.774 217 52.22 1.728 T 11.29 2.710 55.018 to 120.0 0.0 1.1.290 -1.174 216 52.22 0.0676 0.0 14.000 0.947 216 0.0 1.728 2J 22.58 103.040 54.791 to 52.22 120.0 0.0 22.580 1.858 116 52.22 0.0676 0.0 125.620 8.488 116 0.0 1.728 T 11.29 29.450 61.421 to 68.86 120.0 0.0 11.290 1.142 117 52.22 0.0676 0.0 40.740 2.753 K Fact Ir = 5.77 Vel = 7.14 T_ Vel = 7.14 Vel = 7.14 K Factor Vel = 8.22 Vel = 8.22 1 1 _ O Tri 0.0 52.22 60.09 65.316 NEW PATH 69.423 K Factor 7.21 NEW PATH 219 60.09 1.728 T• : ; 11.29 2.710 55.508 to 68.86 120.0 0.0 11.290 1.174 2_18 _ _ 60.09_ 0.0876 0.0 14.000 1.227 218 0.0 1.728 2J 22.58 103.040 55.561 to 0.0 120.0 0.0 22.580 1.858 118 60.09 0.0876 0.0 125.620 11.008 118 0.0 1.728 T 11.29 29.450 64.711 to 1.858 120.0 0.0 11.290 1.142 110 rn n0 n AG7R A A AA 7AA G7A K Fact Ir = 5.77 Vel = 7.14 T_ Vel = 7.14 Vel = 7.14 K Factor Vel = 8.22 Vel = 8.22 1 1 _ O Tri 0.0 60.09 69.423 K Factor 7.21 NEW PATH 221 68.86 1.728 T 11.29 2.710 55.775 to 120.0 0.0 11.290 1.174 220 68.86 0.1127 0.0 14.000 1.578 Vel = 9.42 220 0.0 1.728 2J 22.58 103.110 56.179 to 120.0 0.0 22.580 1.858 120 68.86 0.1127 0.0 125.690 14.171 Vel = 9.42 120 0.0 1.728 T 11.29 29.450 68.492 to 120.0 0.0 11.290 1.142 121 68.86 0.1127 0.0 40.740 4.593 Vel = 9.42 0.0 68.86 74.227 K Factor 7.99 1 Computer Programs by Hydratec Inc. Revision: 50.52.1 r AutoPeaking Summary Wiginton Fire Systems Page 14 2010771 - B1S5RA1 Date 5-19-17 kuto Peaking Summary - List of Pipes for Area Calculated Left Right Side Side From To Length From To Length H8 100 15.760 H1 200 34.780 12.789 H16 102 15.760 202 H9 34.780 H22 104 26.250 204 H17 37.390 H8 100 15.760 H1 200 34.780 H16 102 15.760 202 H9 34.780 H22 104 26.250 204 H17 37.390 Flow Safety Pressure Required Margin Differential Left 7.500 i 1394.109 13.125 0.336 Area Calculated 1394.581 12.789 0.000 Right 7.500 i 1395.026 12.882 0.093 Typical Distance Between Heads = 7.500 Split Point Used in Worst Area Peaked = H5 Split Point Used in Area Calculated = H5 Computer Programs by Hydratec Inc. Revision: 50.52.1 MP N F Z W d a W d m W C M Wigint el FIRE SYSTEMS 699 Aero Lane, Sanford, FL 32771 TEL: 407-585-3200 - FAX: 407-585-3277 www.wigintonfiresystems.com 2010771 Ganesh North - Monroe Road Sanford, FL 32771 Submittal: One Dated: May 19, 2017 Building One The materials submitted in this package... are intended to describe the type and quality of all materials to be used on this project. This submittal intends that all materials, appliances, pieces, parts; and craftsmanship, will be equal to.and/or better than the specific item shown and that actual per foot friction losses will be equal to and/or less than indicated herein. Some of the items included may be substituted due to common procurement, stocking and supply procedures, scheduling requirements, etc. at the option of WFS, however ALL supplied and installed materials will meet the requirements of the applicable NFPA code in effect at the time of installation. UNIT PPC ORDER No. JOB CUSTOMER PO No. Ganesh North PUMP 8 X 8 X 18 VIP CAPACITY 1250 G.P.M. Q 254 FT. HD. MOTOR OOP MAKE Weg FRAM JPV 125 H.P. 3 PHASE 60 CYCLE60 VdL7P R.P.M. CERTIFIED BY- John M. Bolinger DAT02114/16 UNIT DIMENSIONS MOTOR FRAME C D BG UNIT WEIGHT 286 JPV 31 787.4 13111991184 7 00 LBS 545 KGS 324 JPV 2?- 813 151/8 201/16 509.5 1318 BS 600 KGS384 326 JPV 338585 15T 20 LBS 630KGTS 364 JPV 351/4895.3 177/8 454 2111116 3 1508 LBS 685 KGS 365 JPV 351/483 17718 2111/16 1538 LBS 700 KGS17- 3T- 404 JPV 38112978 17718 454 235116 592 1730 LBS 786 KGS 405 JPV 38 112978 177/8 454 235/16 1855 LBS 843 KGS592 405 TCZ 38 1/2 978 17 7/8 23 5116` 592 1890 LBS 859 KGS454 UNIT WEIGHT = PUMP AND MOTOR COMBINED. 010254.0 S- NOTE: 1) ALL DIMENSIONS ARE +1- 1/4' / 6Amm (EXCEPT FOR FLANGE DRILLING). 2) PRIMARY DIMENSIONS ARE INCHES. SECONDARY DIMENSIONS ARE MILLIMETERS. ROTATION 125 CLASS F.F. 08 / 203.2 SUCTION 013 1/2 J 343 FLANGE 8x 07/8 / 22.2 BOLT HOLES EO. SP. ON A 011 3/4 / 298.5 B.C. B.C. STRADDLES 14-JU VNt; A V U BOLT HOLES 0215 B.C. 0 MOUNTING FOOT DETAIL Qj PLAN VIEW _kk CLEARANCE RECOMMENDED TO REMOVE ROTATING ASSY. 125 CLASS F.F. 08 / 203.2 DISCHARGE 0151381 FLANGE 8x 07/8 / 22.2 BOL•T•HOLES EO. SP. ON A 011 3/4 1298.5 B.C. B_C. STRADDLES(i O PATTERSON PUMP COMPANY AGORVXMWCWAlrr 5' 1504 ANSI FLANGE DIMENSIONS SEE MOUNTING FOOT DETAIL) OUTLINE DIMENSIONS FOR 8X8X18VIP W/ VARIOUS MOTORS N4i N0. rRY CO2 -118338 1 PAWN DATE mcaudell NOV, 24, 2010 CALF APPRVo NONE AP 400 35C LU LU u- 30C 0 25C J 2S 200 0 150 100 50 200 w 0 150 a w 100 0 Y 50 m 0 Iii7iii PATTERSON PUMP COMPANY A Subsidiary of The Gormon-Rupp C*Gny P. 0. Box 790 Toccoa, Georgio 30577 Telephone 706-886-2101 Fox 706-886-0023 www.pattersonpunps.com 11 DIA. 1780 RPM 1250 GPM 75 PSI to 137 PSI 173 to 317') MODEL 8x8x18A VIP IMP. D05-104403 CURVE A05-116622 2r o 14" DIA, 83.6% v 20 0- N.RS U) CL z 18"1 DIA. 0 400 800 - 1200 1600 2000 2400 2800 GPM SUCTION GAUGE 0-30# VAC 0-300# PRESS. o 120 150 180 60 210 30 240 0 Cv 30 300 270/ VAC PRESS/ . DIAL SUCTION GAUGE DISCHARGE GAUGE 0-300# PRESS 120 150 180 90 210 ' 60 w 240 30 v 270 WATER 300 DIAL DISCHARGE GAUGE w PATTERSON PUMP COMPANY x A SMIDIARY OF TIC OORNw+•RUPP COMPANY 1/4" N.P T 1/4" N.P.T. SUCTION & DISCHARGE DIAL GAUGES CO2 -99432 VN DATE MEALOR 8/26/05 LE APPRvo. NONE AP 3 r --I 15 n FTA1 000 FULL VOLTAGE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE rairetror NOTE: The drawings included herein are for standard controllers. Actual "as built" drawings may differ from those seen here. ASCOPower Technologies® SBP1000-51(A) Description - Firetrol® FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fire pumps where the capacity of the power source permits full voltage starting. Full voltage is ap- plied to the motor as soon as the controller is actuated. The controller monitors, displays and records fire pump system information. Full voltage starting is simple and low cost and is pre- ferred whenever the utility or emergency generator set will permit this type of starting. Approvals - Firetrol fire pump controllers are listed by Underwriters' Laboratories, Inc., in accordance with UL218, Stondord for Fire Pump Controllers, CSA, Standard forindustrial Control Equipment, and approved by Factory Mutual. They are built to meet or exceed the require- ments of the approving authorities as well as NEMA and the latest editions of NFPA 20, Instollotion of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code. Standard Features—The following are included as stan- dard with each controller: Voltage surge protector Main Disconnect Switch sized for connected motor horsepower and voltage Fire pump Circuit Breaker Single handle Isolating Disconnect Switch/Circuit Breaker mechanism Motor contactor Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency con- dition Built-in Start and Stop push -buttons to bypass auto- matic start circuits Minimum Run Timer Off Delay Timer Daylight Savings Time Option Weekly Test Timer Elapsed Time Meter LrIbr 'fin § 0 Door mounted display interfacepanel featuring a 128 x 64 pixel backlit LED Graphical Display, Membrane Type User Control Push -buttons and easy to read LED Indicators for: POWER AVAILABLE ALARM TRANSFER SWITCH NORMAL (If unit ordered with Automatic Power Transfer Switch) TRANSFER SWITCH EMERGENCY (If unit ordered with Automatic Power Transfer Switch) SYSTEM PRESSURE LOW PUMP RUNNING DELUGE OPEN REMOTE START INTERLOCK ON FAIL TO START MOTOR OVERLOAD EMERGENCY ISO SWITCH OFF (If unit ordered with Automatic Power Transfer Switch) PHASE FAILURE PHASE REVERSAL AUTOMATIC SHUTDOWN DISABLED OVERVOLTAGE UNDERVOLTAGE Digital Pressure Display USB Host Controller and Port Solid State Pressure Transducer Data Log Event Log (3000 Events) True RMS Metering with simultaneous 3 Phase Display of Amps, Volts, Frequency, Pressure and Alarm Mes- sages Disk Error message Disk Near Full message Pressure Error message Motor Over 320% message Local Start message Remote Start message Emergency Start message Fail To Start message Undervoltage message Overvoltage message NEMA Type 2 enclosure Suitable for use as Service Equipment Each standard controller comes with user configurable options for: Interlock Alarm • Low Pressure Audible Low Suction • Pump Run User Defined Input • Weekly Test O EMERSON - Network Power Main Fire Pump Controller The main fire pump controllershall be a factory assembled, wired and tested unit and shall conform to all the requirements of the latest edition of NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection and NFPA 70, National Electrical Code. The controller shall be listed by Underwriters Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Con- trollers, CSA, and Canadian Standards Association CSA -C22.2, Standard for Industrial Control Equipment (cULus), approved by Factory Mutual and approved by the City of New York for fire pump service. Starting Method The controller shall be of the combined manual and auto- matic type designed for: XFull Volta e Starting 1. D Wye (Star -Delta Open Transition Starting D Wye (Star) -Delta Closed Transition Starting I Part Winding Starting I Primary Resistance Reduced Voltage Starting I Autotransformer Reduced Voltage Starting I Digital Soft Start Reduced Current Starting of the Fre pump motor having the horsepower, voltage, phase and frequency rating shown on the plans and drawings. The controller components shall be housed in a NEMA Type 2 (IEC IP11) drip -proof, wall mounted enclosure. Withstand Ratings (Short Circuit Current Ratings) All controller components shall be front mounted, wired and front accessible for maintenance. The minimum withstand rating of the controllers shall not be less than 100,000 Amps RMS Symmetrical at 200-600 Volts'. If the available system fault current exceeds these ratings, the controllers shall be supplied with a withstand rating of 150,000 or 200,000 Amps RMS Symmetrical, as required. Note: 100,000 Amp withstand rating not available in some larger horsepowers. Consult factory for details. Isolation Switch and Circuit Breaker The controller shall include a motor rated combination isolating disconnect switch/circuit breaker, mechanically inter- locked and operated with a single, externally mounted handle. When moving the handle from OFF to ON, the interlocking mechanism shall sequence the isolating disconnect switch ON first, and then the circuit breaker. When the handle is moved from ON to OFF, the interlocking mechanism shall sequence the circuit breaker OFF first, and then the isolating disconnect switch. The isolating disconnect switch/circuit breaker shall be mechanically interlocked so that the enclosure door cannot be opened with the handle in the ON position exceptby a hidden tool operated defeater mechanism. The isolating disconnect switch circuit breaker shall be capable of being padlocked in the OFF position for installation and maintenance safety, and shall also be capable of being locked in the ON position without affecting the tripping characteristics of the circuit breaker. The controller door shall have a locking type handle and three point cam and roller vault type hardware. The circuit breaker trip curve adjustment shall be factory set, tested and sealed for the full load amps of the connected motor. The circuit breaker shall be capable of being field tested to verify actual pick up, locked rotor, and instantaneous trip points after field installa- tion without disturbing incoming line and load conductors. Operator Interface The fire pump controller shall feature an operator interface with user keypad. The interface shall monitor and display motor operating conditions, including all alarms, events, and pressure conditions. All alarms, events, and pressure conditions shall be displayed with a time and date stamp. The display shall be a 128x64 Backlit LED capable of customized graphics and Cyrillic type character display. The display and interface shall be NEMA rated for Type 2, 3R, 4, 4X, and.12 protection and shall be fully accessible without opening the controller door. Thedisplayand user interface shall utilize multiple levels of password protection for system security. A minimum of 3 password levels shall be provided. AmmeterlVoltmeter The fire pump controller operator interface shall be capable of displaying true RMS digital motor voltage and current measurements for all three phases simultaneously. Displays requiring push-button and selector switches to toggle between phases or current and voltage shall not be accepted. Voltage and current shall be measured by True RMS technology to provide the most accurate measurement for all sine waves, including non -sinusoidal waveforms. Average responding meters will not be accepted. Digital Status/Alarm Messages The digital display shall indicate text messages for the status and alarm conditions of: Motor On Sequential Start Time Minimum Run Time Local Start Off Delay Time Remote Start Fail to Start System Battery Low Under Voltage Over Voltage Locked Rotor Trip Over Frequency Emergency Start Motor Over 320% Drive Not Installed Motor Overload Disk Error Printer Error' Disk Near Full Pressure Error The Sequential Start Timerand Minimum Run Timer/Off Delay Timersimershall be displayed as numeric values reflecting the value of the remaining time. LED Visual Indicators LED indicators, visible with the door closed, shall indi- cate: Power Available • Alarm Pump Running • System Pressure Low O EMERSON_ Network Power