Loading...
HomeMy WebLinkAbout3972 Night Heron Dr 18-1919; NSFHParcel ID Number: 17-20-31-502-0000-m 0 Prepared By Daphne Clark and Park Square Homes Return To : 5200 Vineland Road, Suite 200 Orlando, FI 32811 NOTICE OF COMAIENCEMENT. State of Florida. I q County of Seminole. Permit Number GRANT MALOYP SEMINOLE COUNTY CLERK OF CIRCUIT COURT & COMPTROLLER OK 9153 P9 174 (1P9s) CLERK'S 4 2018068022 RECORDED 06/14/2013 02:26:30 PM RECORDING FEES $10.00 RECORDED BY tsmith The undersigned hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Description of Property: LOT 0 Legal Description: WYNDHAM PRESERVE, according to the plat thereof, as recorded in Plat Book 81, Page 933-102, of the/ public records of Seminole County, Florida. Address : ! / (, Sanford FI 32773 2. General Description of Improvements: New Single Family Home 3. Owner Information : Name Park Square Enterprises LLC Address 5200 Vineland Road, Suite 200, Orlando, FI 32811 Telephone (407) 529-3000 4. Fee Simple Title Holder: N.A. 5. Contractor Name and Address: Name Park Square Homes Address 5200 Vineland Road, Suite 200, Orlando, FI 32811 Telephone (407) 529-3000 6. Surety: N.A. 7. Lender: Name Fifth Third Bank Address 5050 Kingsley Dr. MD: 1 MOC3J Cincinnati, OH 45227 8. Persons within the State of Florida designated by the Owner upon whom notices or other documents may be served as provides by 713. l3(1)(a)7., Florida Statutes: N.A 9. In addition to himself, Owner designates the following to receive a copy of the Lienor's Notice as provided in 713.13(1)(b), Florida Statutes. N.A. 10. Expiration date of notice of commencement: One year from the date of recording. WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTENT TO OBTAIN FINANCING, CONSULT YOUR LENDER OT ATTORNEY•BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. 11. Date Signed : 4 Signature of Owner's Agent : A Vishaal Gupta Executive Vice President, Park Square Enterprises LLC Sworn to and subscribed before me this day by Vishaal Gupta who is personally known to me and did not produce ID. Notary Public Daphne Clark My commission expires: 6/27/19 Ae Serial No. FF209108 Notary Signature: A P a „pt O C' Mgt Notate E Napsi0. 4 e CITY Of SXR ORD FIRE DEPARTMENT 3 Building & Fire Prevention Division APR ', ZO1a PERMIT APPLICATION S-1ApplicationNo- Q 1 Documented Construction Value: S 39,12-LAc o Job Address:S772 4I/&//t. (Gr , Historic District: Yes NoFv4 Parcel ID: 17-20-31-5024000- Q(gE 0 . Residentiala Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: NEW SINGLE FAMILY HOME WYNDHAM PRESERVE LOT # Plan Review Contact Person: Daphne Clark Title: Phone:407-257-6940 Fax: Email: Parksquare@PermitsPemnitsPermits.com Property Owner Information Name Park Square Enterprises LLC Street: 5200 Vineland Rd STE 100 City, State Zip: Orlando FL 32811 Phone: Resident of property? : Contractor Information Name VISHAAL S GUPTA - PARK SQUARE HOMES Street: 5200 Vineland Rd STE 100 City, State Zip: Orlando FL 32811 Name: Street: City, St, Zip: Bonding Company: N/A Address: Phone: 407-5293100 Fax: State License No.: CRC1330351 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Leader: N/A Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6t1 Edition (2017) Florida Building Code Revised: January I, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current [CC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. dL:-:1- 141(ela-- Signature of Owner/Agent Date VISHAAL S GUPTA Print Owner/Agent's ame y V Signature of otary-State of Florida Dafe Signatur of Contractor/Agent ate VISHAAL S GUPTA Print Contra r/Agent's Name / // 46V 1? f Signature of Notary -State of Florida Dat 4 D. A CIRRI( µ' ¢ N D. A CLARIC MY COMMISSION I FF 209108 * W OMISSION I FF 209108 EXPIRES: June 27, 2019 ,+ EXPIRES: June 27.2019 ti h 8t nded iAN 8udpel Notary SerMod 'nor no' fdcd 1Mt 8U*l N0" Seft, Owner/Agent is YES Personally Known to Me or Contractor/Agent is YES Personally Known to Me or Produced ID N/A Type of ID Produced ID N/A Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building[A Electrical E Mechanical fR Plumbing® Gas[] Roof Construction Type: V 5 Occupancy Use: Flood Zone: -4 i-ff Total Sq Ft of Bldg: ;O 12 Min. Occupancy Load: l ('IV # of Stories: I -- 23 New Construction: Electric - # of Amps_ ?-,-jrp Plumbing- # of Fixtures Fire Sprinkler Permit: Yes No ?' # of Heads APPROVALS: ZONING: Akce6 Q UTILITIES: Fire Alarm Permit: Yes No WASTE WATER: ENGINEERING: d'rL 4 SQ- la FIRE: BUILDING: sG -74-I1 COMMENTS: Ok to construct single family home with setbacks and impervious area shown on plan. 3y • 0 to -^`P- Pe- OA uM t- A , GA, Revised: January I, 2018 Permit Application CITY Of,... . Building & Fire Prevention DivisionANFORD . A? ' l1'1 . PERMIT APPLICATION FIRE DEPARTMENT 1ApplicationNo: Documented Construction Value: $1 02t 30 Job Address:.;— q72, &19/ 10YI Historic District: Yes NoR Parcel ID: 17-20-31-502-0000- Q(pE 0 - ResidentialW1 Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: NEW SINGLE FAMILY HOME WYNDHAM PRESERVE LOT # Plan Review Contact Person: Daphne Clark Phone: 407-257-6940 Fax: Title: Email: Parksquare@PermitsPermitsPermits.com Property Owner Information Name Park Square Enterprises LLC Phone: Street: 5200 Vineland Rd STE 100 City, State Zip: Orlando FL 32811 Resident of property? : Contractor Information Name VISHAAL S GUPTA - PARK SQUARE HOMES Phone: 407-5293100 Street: 5200 Vineland Rd STE 100 Fax: City, State Zip: Orlando FL 32811 State License No.: CRC1330351 Arch itect/Eng 1 neer Information Name: Phone: Street: City, St, Zip: Bonding Company: N/A Address: Fax: E-mail: Mortgage Lender: N/A Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 1053 Shall be inscribed with the date of application and the code in effect as of that date: 61° Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured of the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Au-', — 141(ela--- Signature of Owner/Agent I Date VISHAAL S GUPTA Print Owner/Agents ame [ y T t7 Signature of otary-State of Florida D e Signatur of Contractor/Agent "It, VISHAAL S GUPTA PrF Agent's Name 461w(f— Signature tary-State of Florida r o D. A DARK . n ;!u o D A CLARK WCOMMISSION 0 FF209108MYCOMMISSION0FF209108 EXPIRES: June 27, 2019 EXPIRES: June 27, 2019 r a 6WM UM 8udpel Notary SeMcet for na' 8auged iku Budd Notary Soft Owner/Agent is YES Personally Known to Me or Contractor/Agent is YES Personally Known to Me or Produced ID N/A Type of ID Produced ID N/A Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: 44 / 'Z WASTEWATER: ENGINEERING: FIRE: BUILDING: COMMENTS: Revised: January I, 2018 Permit Application P 4 City of Sanford Planning and Development Services Engineering — Floodplain Management Flood Zone Determination Request Form Name: Michelle Parkison Firm: Park Square Homes Address: 5200 Vineland Road, Suite 200 City: Orlando State: FL Zip Code: 32811 Phone: 407-529-3135 Fax: Email: mparkison@parksquarehomes.com Property Address: 3972 Night Heron Drive Property Owner: Park Square Enterprises, LLC Parcel identification Number: 17-20-31-502-0000-0680 Phone Number: 407-529-3000 Email: The reason for the flood plain determination is: E New structure Existing Structure (pre-2007 FIRM adoption) Expansion/Addition Existing Structure (post 2007 FIRM adoption) Pre 2007 FIRM adoption = finished floor elevation 12" above BFE Post 2007 FIRM adoption = finished floor elevation 24" above BFE (Ordinance 4360) OF 'ICIAL USE ONL Flood Zone: X Base Flood Elevation: N/A Datum: N/A FIRM Panel Number: 120294 0090 F Map Date: Sept. 28, 2007 The referenced Flood Insurance Rate Map indicates the following: The parcel is in the: floodplain floodway A portion of the parcel is in the: floodplain floodway The parcel is not in the: M floodplain floodway The structure is in the: floodplain floodway The structure is not in the: floodplain floodway If the subject property is determined to be flood zone 'A', the best available information used to determine the base flood elevation is: BP# 18-1919 Reviewed by: Michael Cash, CFM Date: April 30, 2018 0 CITY OF Application for Right -of -Way SWORD Utilization Permit PLANNING & DEVELOPMENT 300 North Park Avenue, Sanford, Florida 32771 SERVICES DEPARTMENT Phone: 407.688.5140 Fax: 407.688.5141 This permit authorizes work done in the City of Sanford's right-of-way in accordance with the City's regulations and the attached construction plans approved as part of this permit. It does not approve any work within any other jurisdiction's right-of-way. All requested Information below as well as a current survey, site plan or plat clearly identifying the size and location of the existing right-of-way and use shall be provided or application could be delayed. Project Location/Address: Aerial Installation Directional Bore Jack &Bore Underground Utilities Roadway open cut -single lane Roadway open cut —multi lane Small Cell/Wireless Co -location n New pole Q Other (describe): Brief Description of Work: DRIVEWAY FOR NEW SINGLE FAMILY HOME WYNDHAM PRESERVE LOT # Schedule of Work: Start Date: Completion Date: Emergency Repairs - Reason: Excavation Information: Total Length (Feet) # Open Roadway Cuts: Aerial Info: Length (Feet) # of Poles (Existing) (New) This Application is submi Signature: Print Name: VISHAAL S GUPTAdt Firm/Company: VI AAL S GUPTA - PARK SQUARE HOMES Date: Address: 5200 Vineland Rd., STE 100, Orlando FL 32811 Phone: 407-257-6940 Fax: Email: Parksquare@PermitsPermitsPennits.com Notice: It Is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City of Sanfo rd's jurisdiction, and the right, title, or Interest in the land to be entered and used by the permitee. The permitee shall at all times assure all risks and indemnify, defend, save harmless the City of Sanford and the Sanford Airport Authority from and against all loss, cost, damage, or expense, arising in any manner, on account of the permit request by said permittee of the aforesaid rights and privileges. In the event that any future construction of roadways, utilities, stormwater facilities, or any general maintenance activities by the City becomes in conflict with the above permitted activity, the permittee shall remove, relocate and/or repair as necessary at no cost to the City of Sanford, insofar as such facilities are In the public right-of-way. The applicant must notify the City 48 hours prior to construction and again when construction is completed via the following email address: michael.cash0sanfordfl.aov I have read and upi jrryd thepbdve statement and by signing this application I agree)o its terms. Signature: Application No: Reviewed: Public Works Utilities Engineering Inspected By: Conditions': Date: Fee: Date: Date: Date: Date: Date: SCPA Parcel View: 17-20-31-502-0000-0680 http://parceidetai I.scpafl.orgiParceiDetailinfo.aspx?PID=1720315020... tpCIA Property Record Card P Parcel: 17-20-31-502-0000-0680 rrs..aaoourm acsox Property Address: 3972 NIGHT HERON OR SANFORD. FL 32773 I Parcel Information Value Summary Parcel Owner 17-20-31-502-0000-0680 BRISSON INV LLC Property Address 3972 NIGHT HERON DR SANFORD, FL 32773 Mailing 27 N SUMMERLIN AVE ORLANDO, FL 32801 Subdivision Name WYNDHAM PRESERVE Tax District S1-SANFORD DOR Use Code 00-VACANT RESIDENTIAL Exemptions Legal Description LOT 68 WYNOHAM PRESERVE LPB 81 PGS 93-102 Taxes 2018 Working 2017 Certified Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 0 0 Depreciated Bldg Value Depreciated EXFT Value Land Value (Market) 51,000 14.000 Land Value Ag Just/Market Value " 51.000 14.000 Portability Adj Save Our Homes Adj 0 s0 Amendment 1 Adj 0 0 P&G Adj 0 0 Assessed Value 51.000 14,000 Tax Amount without SOH: $266.00 2017 Tax Bill Amount $266.00 Tax Estimator Save Our Homes Savings: $0.06 Does NOT INCLUDE Non Ad Valorem Assessments Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 51,000 0, 51,000 Schools 51.000 s0 51.000 City Sanford 51.000 0 51.000 SJWM(Saint Johns Water Management) 51-000 0 ~ 51.000 County Bonds 51,000 0 1 51,000 Description Date Book Page Amount Qualified Vac/Imp No Sales omparable Sales Land Method Frontage Depth Units Unils Price Land Value LOT 1 $51,000.00 $51,000 Building Information Penn Its - — - Permit 9 Description Agency Amount CO Date Permit Date I of 2 3/29/2018, 8:10 PM LIMITED POWER OF ATTORNEY DATE: I HEREBY NAME AND APPOINT: Alison Perrotti. Anthony Perrotti, Janey Jahner, Allan Jahner, Gustav Botes, KarenMcAdams. EACH AN AGENT OF: PARK SQUARE HOMES TO BE MY LAWFUL ATTORNEY IN FACT TO ACT FOR ME AND APPLY TO THE BUILDING DEPARTMENT OF: C FOR A BUILDING PERMIT FOR WORK TO BE PERFORMED AT LOT NUMBER SUBDMSION: ADDRESS: / cJ/ PARCEL ID : .?? 7 Alf Ot AND TO SIGN MY NAME AND DO ALL THINGS THAT ARE NECESSARY TO THIS APPOINTMENT. VISHAAL S GUPTA NAME OF CONTRACTOR.) SIGNATURE OF CONTRACTOR.) STATE CERT. # CRC1330351 CONTRACTOR'S STATE REGISTRATION NUMBER.) The foregoing instrument was knowl g b fore me this DATE: BY: VISH L SAUPTA STATE OF FLORIDA COUNTY OF ORANGE. NAME: DA.Gark My Commission # FF209108 My Commission Expires 6127119 NOTARY: Who is personally known to me and did not lake an oath. 0.mA4R SEAL. REQUIRED INSPECTION SEQUENCE PARK SQUARE HOMES SFRDETACHED Permit # NG PERMIT r Max Inspection Descri tion Form board / Foundation Survey 10 Slab / Mono Slab Pre our 20 Lintel / Tie Beam / Fill / Down Cell 30 Sheathing — Walls 30 Sheathing — Roof 40 Roof Dry In 50 Frame 60 Insulation Rough In 70 Drywall / Sheetrock 40 70 Lath Inspection 50 1000 Final Roof 50 1000 Final Stucco / Siding 80 1000 Insulation Final 1000 Final Single Family Residence Address: r+nYc1:%b+"• 4e{f.t ^A.c+ n: Y; ."J- .f:•: -. •1'.1 ELECTRIGALlPER1VIIT,:; ;' .ec:.':2;,:ic' _.:=;s:<'::•-r>:. Min Max Inspection Description 10 Underground Electric 10 Footer / Slab Steel Bond 20 30 Temporary Underground Power (TUG) 30 Electric Rough 1000 Electric Final Min Max inspection Description 10 Plumbing Underground 20 Plumbing Tubset 10 1000 Plumbing Sewer 1000 Plumbing Final N E.CHANI CA•L PERIVII t<:=. _: Min Max Inspection Description 10 Mechanical Rough 1000 Mechanical Final REVISED: June 2014 SCPA Parcel View: 17-20-31-502-0000-0680 http://parce ldetai i.scpaf .org/Parcei Detai I In fo.aspx?P I D=1720315020... j CFA Property Record Card i P Parcel: 17-20-31-502-0000-0680 esrrrsaoourrry aonox Property Address: 3972 NIGHT HERON DR SANFORD, FL 32773 t_ Parcel Information Value Summary Parcel 17-20- 31-502-0000-0680 BRISSON INV LLC Owner Property Address3972 NIGHT HERON OR SANFORD. FL 32773 Mailing 27 N SUMMERLIN AVE ORLANDO. FL 32801 Subdivision Name WYNDHAM PRESERVE Tax District S1- SANFORD I OOR Use Code 00-VACANT RESIDENTIAL i Exemptions Legal Description I LOT 68 j WYNDHAM PRESERVE 1 PS 81 PGS 93-102 Taxes 2018 Working 2017 Certified Values Values Valuation Method Cost/ Market CosUMarket Number of Buildings 0 0 Depreciated Bldg Value Depreciated EXFT Value Land Value (Market) 51.000 14,000 Land Value Ag Just/Market Value " 51,000 14.000 Portability Adj Save Our Homes Adj 0 so Amendment 1 Adj 0 so P&G Adj s0 0 Assessed Value 51. 000 14.000 Tax Amount without SOH: $266.00 2017 Tax Bill Amount $266.00 Tax Estimator Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 51,000 0 51.000 Schools 51,000 0 51,000 City Sanford 51. 000 0 51.000 SJWM(Saint Johns Water Management) 51.000 so, 51.000 County Bonds 61. 000 0 51.000 Sales Description Date Book Page Amount Qualified Vac/Imp No Sales omparable Sales Land Method Frontage Depth Units Units Price Land Value LOT 1 $51. 000.00 $51,000 Building Information Permits Permit p Description Agency Amount CO Date Pernk Date I of 2 3/29/2018, 8:10 PM 111 COUNTY OF SEMINOLE I3A -], A voIMPACTFEESTATEMENT STATEMENT NUMBER: 18100004 DATE: May 07, 2018 BUILDING APPLICATION #: 18-10000437 30/ a BUILDING PERMIT NUMBER: 18-10000437 UNIT ADDRESS: NIGHT HERON DRIVE 3972 17-20-31-502-0000-0680 TRAFFIC ZONE-022 JURISDICTION• SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: PARK SQUARE ENTERPRISES LLC ADDRESS: 5200 VINELAND RD STE 100 ORLANDO FL 32811 LAND USE: WYNDHAM PRESERVE TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 3972 NIGHT HERON DRIVE / WYNDHAM PRESERVE / SFR FEE - BENEFIT RATE UNIT CALC UNIT TOTAL DUETYPEDISTSCHEDRATEUNITSTYPE ROADS-ARTERIALS CO -WIDE ORD Single Family Housing 705.00 ROADS -COLLECTORS N/A Single Family Housing 00 FIRE RESCUE N/A LIBRARY CO -WIDE ORD Single Family SCHOOLS Housingg 54.00 CO -WIDE ORD Family Housing 91000.00 PARKS N/A LAW ENFORCE N/A DRAINAGE N/A 1.000 dwl unit 705.00 1.000 dwl unit 00 00 1.000 dwl unit 54.00 1.000 dwl unit 91000.00 00 00 00 AMOUNT DUE 9,759.00 PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE DATE ABOVE BUT NO LATER THAN CERTIFICATE OF OCCUPARY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE BUSINESS OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT ISSUED WITHIN 60 CALENDAR DAYS FROM THE DATE ABOVE STATE COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 068 Pembroke A LHG - W Builder Name: Park Square Homes Street: 3972 Night Heron Dr. Permit Office: City of Sanford City, State, Zip: Sanford , FL , Permit Number: Owner: Park Square Homes Jurisdiction: 691500 Design Location: FL, Orlando County:: Seminole (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2735.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block . Int Insul, Exterior R-4.1 1288.00 ft2 b. Frame - Wood, Exterior R-11.0 1242.00 (12 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11.0 205.33 tt2 4. Number of Bedrooms 4 d. N/A R= 112 10. Ceiling Types (1493.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R-30.0 1493.00 ft2 6. Conditioned floor area above grade (112) 2380 b. N/A R= 112 Conditioned floor area below grade (ft2) 0 c. N/A R. ft2 11. Ducts R ft2 7. Windows(274.6 sqft.) Description Area a. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor 6 476 a. U-Factor: Dbl. U-0.55 149.05 ft2 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.58 96.00 f12 12, Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 41.0 SEER:16.00 c. U-Factor: Dbl, U=0.54 29.56 f12 SHGC: SHGC-0.25 13. Heating systems kBlu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 39.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 4.811 ft. Area Weighted Average SHGC: 0.234 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2380.0 sqft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 1334.00 ft29 b. Conservation features b. Floor Over Other Space R-0.0 887.00 f12 None c. other (see details) R= 159.00 ft2 15. Credits Pstat Glass/Floor Area: 0.115 Total Proposed Modified Loads: 66.98 PASSTotalBaselineLoads: 71.02 1 hereby certify that the plans and specifications covered by Review of the plans and S741, this calculation are in compliance with the Florida Energy specifications covered by this Code. otgltatlysigned byNafael calculation indicates compliance i Rafael lzquierdo ttq-tetdo with the Florida Energy Code. I; Date: 201804.12085'00 3:20-01 PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 1 hereby certify that this building, as designed, is in compliance Florida Statutes. r with the Florida Energy Code. / CDD W'E OWNER/ AG BUILDING OFFICIAL: DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested In accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. 4/ 12/2018 8:51 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Pagel of 5 in RECORD COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 068 Pembroke A LHG - W Street: 3972 Night Heron Dr. City, Slate, Zip Sanford , FL , Owner: Park Square Homes Design Location: FL, Orlando Builder Name: Park Square Homes Permit Office: City of Sanford Permit Number: 11 . Jurisdiction: 6#500 8 9 19 County:: Seminole (Florida Climate Zone 2) SANFp O p R OARTTAEa 1. New construction or existing New (From Plans) 9. Wall Types (2735.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R-4.1 1288.00 f12 b. Frame - Wood, Exterior R=11.0 1242.00 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11.0 205.33 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (1493.0 sqft ) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1493.00 ft2 6. Conditioned floor area above grade (ft2) 2380 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(274.6 sgfl.) Description Area a. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor 6 476 a. U-Factor: Dbl, U=0.55 149.05 ft2 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.58 96.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 41.0 SEER:16.00 c. U-Factor: Dbl, U=0.54 29.56 f12 SHGC: SHGC=0.25 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A f12 a. Electric Heat Pump 39.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 4.811 ft. Area Weighted Average SHGC: 0.234 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2380.0 sqft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 1334.00 ft2 b. Conservation features b. Floor Over Other Space R=0.0 887.00 ft2 None c. other (see details) R. 159.00 ft2 15. Credits Pstat Glass/Floor Area: 0.115 Total Proposed Modified Loads: 66.98 PASSTotalBaselineLoads: 71.02 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. Digitally signed by Rafael Rafael Izquierdo Uti.ierdo PREPARED BY: Date: 201804.120833:20-04.00' DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGDATV - /Z_' E: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIA DATE: tiOiKHE SrA O Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. . 4/12/2018 8:51 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 Z41 VA11.1 1WITIV] PROJECT Title: Lot 068 Pembroke A LHG - W Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 2380 Lot # 68 Owner Name: Park Square Homes Total Stories: 2 Block/Subdivision: WP of Units: 1 Worst Case: No PlatBook: Builder Name: Park Square Homes Rotate Angle: 0 Street: 3972 Night Heron Dr. Permit Office: City of Sanford Cross Ventilation: No County: Seminole Jurisdiction: 691500 Whole House Fan: No City, Stale, Zip: Sanford , Family Type: Single-family FL. New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Orlando FL_ORLANDO_INTL_AR 41 91 70 75 526 44 Medium BLOCKS Number Name Area Volume 1 Blockl 2380 21820.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1 st Floor 1334 12406.2 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1046 9414 No 4 3 1 Yes Yes Yes FLOORS Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor 2nd Floor --_- __-_ 27 W 11 0.29 0 0.71 2 Floor over Garage 2nd Floor __-_ ____ 132 ft2 11 0.29 0 0.71 3 Slab -On -Grade Edge Insulatio 1 st Floor 138 ft 0 1334 ft2 0.29 0 0.71 4 Floor Over Other Space 2nd Floor -_-_ __-- 887 ft2 0 0.29 0 0.71 ROOF Roof Gable Roof Solar SA Emitt Emilt Deck Pitch Type Materials Area Area Color Absor. Tested Tested Insul. deg) 1 Gable or Shed Composition shingles 1670 f12 374 f12 Dark 0.9 N 0.9 No 0 26.6 ATTIC Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Vented 300 1493 112 N N 4/12/2018 8:51 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) 1 st Floor 30 Blown 1493 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Frame - Wood 2nd Floor 11 29 0 9 0 261.0 fie 0 0.25 0.8 0 2 N Exterior Concrete Block - Int Insul 1st Floor 4.1 40 0 9 4 373.3 112 0 0 0.8 0 3 E Exterior Frame - Wood 2nd Floor 11 40 0 9 0 360.0 ft2 0 0.25 0.8 0 4 E Exterior Concrete Block - Int Insul 1st Floor 4.1 20 0 9 4 186.7 112 0 0 0.8 0 5 S Exterior Frame - Wood 2nd Floor 11 29 0 9 0 261.0 f12 0 0.25 0.8 0 6 S Exterior Concrete Block - Int Insul 1st Floor 4.1 38 0 9 4 354.7 112 0 0 0.8 0 7 W Exterior Frame - Wood 2nd Floor 11 40 0 9 0 360.0 ft2 0 0.25 0.8 0 8 W Exterior Concrete Block - Int Insul 1 st Floor 4.1 40 0 9 4 373.3 f12 0 0 0.8 0 9 Garage Frame - Wood 1st Floor 11 22 0 9 4 205.3 ft2 0 0.25 0.8 0 DOORS Ornt Door Type Space Storms U-Value Width Height Area FI In Ft In 1 E Insulated 1st Floor None 39 3 8 24 f12 2 Wood 1st Floor None 39 2 8 7 18.7 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 e 3 Metal Low-E Double Yes 0.55 0.22 N 30.0 ft2 1 It 0 in' 1 It 4 in Drapes/blinds None 2 e 3 Metal Low-E Double Yes 0.54 0.25 N 12.0 ft2 1 It 0 in 1 ft 4 in Drapes/blinds None 3 e 4 Metal Low-E Double Yes 0.55 0.22 N 16.3 ft2 1 It 0 in 12 It 4 in Drapes/blinds None 4 e 4 Metal Low-E Double Yes 0.54 0.25 N 9.3 02 12 It 0 in 5 It 0 in Drapes/blinds None 5 s 6 Metal Low-E Double Yes 0.54 0.25 N 4.3112 1 110 in 12 It 4 in Drapes/blinds None 6 s 6 Metal Low-E Double Yes 0.55 0.22 N 16.3 ft2 1 It in 1 It 4 in Drapes/blinds None 7 s 6 Metal Low-E Double Yes 0.58 0.25 N 48.0 ft2 12 It 4 in 1 It 4 in None None 8 w 7 Metal Low-E Double Yes 0.54 0.25 N 3.9 ft2 1 It in 1 It 4 in Drapes/blinds None 9 w 7 Metal Low-E Double Yes 0.55 0.22 N 6.0 ft2 1 It 0 in 1 It 4 in Drapes/blinds None 10 w 7 Metal Low-E Double Yes 0.55 0.22 N 15.0 ft2 1 It 0 in 1 It 4 in Drapes/blinds None 11 w 8 Metal Low-E Double Yes 0.55 0.22 N 65.4 ft2 1 It 0 in 1 ft 4 in Drapes/blinds None 12 W 8 Metal Low-E Double Yes 0.58 0.25 N 48 0 ft2 9 It 4 in 1 N 4 in None None 4/12/2018 8:51 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 GARAGE Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 418 h2 418 fie 64 ft 9.311 1 INFILTRATION Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000408 2545.7 139.75 262.83 .3665 7 HEATING SYSTEM System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heal Pump/ Split HSPF:9 39 kBtu/hr 1 sys#1 COOLING SYSTEM System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 41 kBtu/hr 1230 cfm 0.75 1 sys#1 HOT WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None f12 DUCTS v # Supply ---- Location R-Value Area Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 476 ft2 2nd Floor 119 ft2 Prop. Leak Free 2nd Floor --- cfm 71.4 cfm 0 03 0.50 1 1 . 4/12/2018 8:51 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolingj Jan Feb MarA r Ma X Jun Jul Au Se Oct Nov Dec Heatin[XJan Feb Mar IdApr May Jun Jul AuSep Oct XNov DecVentin 1] JanlX1] FebMar l Apr [ l May Jun Jul Aug Se Oct XX]] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/12/ 2018 8:51 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 3972 Night Heron Dr. Permit Number: Sanford , FL , MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require (hat an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402 5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Instal latlon.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended wealherslripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -filling flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -filling doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 4/12/2018 8:51 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. Fireplaces and stoves complying with Section R402.4.2 and Section A1006 of the Florida Building Code, Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or 7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. Postconstruction test: Total leakage shall be measured with a pressure differential of 0 1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage lest shall not be required where the duels and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the lest and provided to the code official. R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping Insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or below 55°F (13°C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping Insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403 5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 4/12/2018 8:51 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complian Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 31/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38"C to 601C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be lurned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -healing category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers (hat close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM) MINIMUM EFFICACY a CFM/WATT) AIRFLOW RATE MAXIMU CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/wall Any Bathroom, utility room 10 1.4 cfm/watt 90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 4/12/2018 8:51 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7. or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of (hat load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and Ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.80C). R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool healing systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI 2 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 4/12/2018 8:51 AM EnergyGaugeO USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatorg)he energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 4/12/2018 8:51 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 3972 Night Heron Dr., Sanford, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (112) 7. Windows" Description a. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.58 SHGC: SHGC=0.25 c. U-Factor: Dbl, U=0.54 SHGC: SHGC=0.25 d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1288.00 ft2 b. Frame - Wood, Exterior R=11.0 1242.00 ft2 1 c. Frame - Wood, Adjacent R=11.0 205.33 ft2 4 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 1493.00 ft2 2380 b. N/A R= ft2 Area c. N/A R= ft2 149.05 f12 11. Ducts R ft2 a. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor 6 476 96.00 f12 12. Cooling systems kBlu/hr Efficiency 29.56 ft2 a. Central Unit 41.0 SEER:16.00 ft2 4.811 ft. 0.234 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1334.00 ft2 b. Floor Over Other Space R=0.0 887.00 ft2 c. other (see details) R= 159.00 ft2 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits kB1u/hr Efficiency 39.0 HSPF:9.00 Cap: 50 gallons EF: 0 9 Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building -COESr,,, Construction through the above energy saving features which will be installed (or exceeded) ..yy0 o in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,,'''% 'Pn based on installed Code complianftres. Builder Signature: Date: A c a Address of New Home: ,Q / City/FL Zip: F6-32*77,3 WE Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/12/2018 8:51 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 068 Pembroke A LHG - W Builder Name: Park Square Homes Street: 3972 Night Heron Dr. Permit Office: City of Sanford City, State, Zip: Sanford , FL , Permit Number: Owner: Park Square Homes Jurisdiction: 691500 Design Location: FL, Orlando COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/12/2018 8:51 AM EnergyGaugeO USA - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 1 wrightsoft• Project Summary Enure House One Stop Cooling and Heating 7225 Sardsoove Cf. Sute 1. Wirier Park, FL 32792 Plane: (407) 629.6920 Fax, (407) 629 - 9307 Web. wwwOneStopCoolirg corn License: CAC032444 For: Park Square Homes 3972 Night Heron Dr., Sanford, FL Notes: Design Information Weather: Orlando Executive AP, FL, US Job: Lot 068 Pembroke A LHG - .. Date: 09/14/2017 By: RI/MC/LM Winter Design Conditions Summer Design Conditions Outside db 44 OF Outside db 93 OF Inside db 70 OF Inside db 75 OF Design TD 25 OF Design TD 18 OF Daily range L Relative humidity 50 Moisture difference 45 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21183 Btuh Structure 21352 Btuh Ducts 2537 Btuh Ducts 6932 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 ctm) 0 Btuh none) none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23719 Btuh Use manufacturers data n Rate/swin multiplier 0.98 Infiltration Equipment sensible load 27605 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3353 Btuh Ducts 1297 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling none) Area (ft2) 2428 2428 Equipment latent load 4650 Btuh Volume (ft3) 22255 22255 Air changes/hour 0.41 0.21 78 Equipment Total Load (Sen+Lat) Req. 0.75 SHR 32254 3.1 Btuh tonEquiv. AVF (cfm) 152 total capacity at Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR6042H1 Cond 4TWR6042H1 AHRI ref 7563302 Coil TEM6A0C42H41++TDR AHRI ref 7563302 Efficiency 9 HSPF Efficiency 13.0 EER,16 SEER Heating input Sensible cooling 30750 Btuh Heating output 39000 Btuh @ 470F Latent cooling 10250 Btuh Temperature rise 0 OF Total cooling 41000 Btuh Actual air flow 0 cfm Actual air flow 1367 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermbstat Load sensible heat ratio 0.86 Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 22369 Btuh,100 AFUE Calculations approved by ACCA to meet all requirements of Manua! J 8th Ed. C - wrlghtsoft- 2018-Apr-1208:1335 r y^ -- --u-• ^ Right-Sute91.1riversal2018 18.0.11 RSU16202 Page 1 A • alc and EPL TempUt 068 PembrokeA LHG - W.np Calc - MJ8 WLw laces: W wrightsoft• Right-JO Worksheet Entire House One Stop Cooling and Heating Job: Lot 068 Pembroke A LHG - W Date: 09/14/2017 By: RI/MC/LM 7225 Sardscove Cl. Sute 1. Winter Park FL 32792 Phone. (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCoolirg.com License: CA0032444 1 Room name Entire House BED3 2 Evosedwail 276.0 It 26.0 A 3 Room height 92 f1 d 90 It heat/000l 4 Room dimensions 1.0 x 160.8 ft 5 Room area 2428.3 fF 1608 iF Ty ConsYnxbon number U-value BtuhW-19 Or HTM Bahl" Area OF) or perimeter (it) Load Btuh) Area (fF) or perimeter (A) Load Btuh) Heat Cool Goss N/P/S Heat Cool Gross NIPS Heat Cool 6 W W V)! 12B-Os6v 13A-flocs 12B•09w 0.097 0.143 0.097 n n a 2A6 363 2.46 2.83 2.91 2.83 261 372 360 261 372 318 643 1351 783 738 1083 899 122 0 113 122 0 98 299 0 240 344 0 276 11 4A5-2om 495.21m 0.550 0.540 a a 13.97 13.71 2723 29A1 30 12 0 0 419 165 817 353 15 0 0 0 209 0 408 0I{- G 4 J G 13A-40 s 4AS-20m 4B5.2hn 0.143 0 550 0540 a a a 3.63 13.97 13.71 2.91 2723 19.52 186 16 9 136 0 6 495 228 128 397 445 182 0 0 0 0 0 0 0 0 0 0 0 0 IIDO 128. 09w 0. 390 0. 097 a s 9. 90 2A6 1231 2. 83 24 261 24 261 238 643 295 738 0 0 0 0 0 0 0 0 W13A- 40cs 4A5- 20m 05. 20m 0. 143 0. 540 0. 550 s s s 3. 63 13. 71 13. 97 2. 91 14. 76 13. 45 353 4 16 285 0 13 1034 59 228 829 64 220 0 0 0 0 0 0 0 0 0 0 0 0 VVVjjjlll 4A5. 2omd 128. 09N 4A5. 2om 4A5- 20m 4A5. 2om 13A- 40cs 4A5. 2om 4A5. 2omd 0580 0. 097 0. 540 0. 550 0. 550 0. 143 0550 0. 580 s w w w w w w w 14. 73 2. 46 13. 71 13. 97 13. 97 3. 63 13. 97 14. 73 1567 2. 83 29A 1 2723 2723 2. 91 2723 19. 39 48 360 4 6 15 372 65 48 48 335 0 0 0 259 0 39 707 825 53 84 209 939 913 707 752 948 115 163 408 753 1780 931 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 q 12C-0sw 0.091 231 1.52 205 186 430 282 0 0 0 0 t- D 11 DO 0.390 n 9.90 1231 19 19 185 230 0 0 0 0 C 16B-30ad 0.032 081 1.76 1495 1495 1215 2635 161 161 131 283 F 19A•0bscp 0.295 2b1 2.00 28 28 79 56 0 0 0 0 F 19c-19sq) 0.049 0.43 031 133 133 57 41 0 0 0 0 F 22A-qxn 1.180 29.96 0.00 1334 138 4135 0 0 0 0 0 61 c) AED excursion 811 19 Erlvelope losston 16952 16965 880 1292 12 a) Infiltration 4230 1537 392 142 b) Room ventilation 0 0 0 0 13 Internal gains: Oocupanls@ 230 5 1150 1 230 Appliances/ other 1700 0 Subtotal ( lines 6 b 13) 21183 21352 12721 1665 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redislritwtion 0 0 0 0 14 Subtotal 21183 21352 1272 1665 15 Duct lows 1 12% 329/6 2537 6932 10% 289% 122 468 Total room load 23719 28284 1394 2132 Air required ((*m) 1 0 13671 1 0 103 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i - 0} tr wrlghtao4t' 2018-Apr-1208:1335 Right - Su re® Universal 2018 18 0.11 RSU16202 Page 1 air and EPL Temp\Lot 068 Pembroke A LHG - W (up Calc = Mf8 Hocw faoes: W wrightsoft• Right-J® Worksheet Entire House One Stop Cooling and Heating Job: Lot 068 Pembroke A LHG - W Date: 09/14/2017 By: RI/MC/LM 7225 Sardscove Q. Sute 1, Wirter Park FL 32792 Phone. (407) 629 - 6920 Fax: (407) 629. 9307 Web: w vwOreStopCoolirg com License. CA0032444 1 Room name KWIC MTOI 2 EVosed well IUD 4 0 It 3 Room height 9.0 It heaVbool 9.0 It heatbool 4 5 Roomdmenaons Room area 1.0 x 683 8 683 IF 50 x 3.5 ft 175 W Ty Construction number U-value ek"W -°1 Or HTM Btu Fvtlh Area OF) or perimeter (A) Load BWh) Area W) or perimeter (fl) Load Bluh) Heat Cool Gross N/P/S Heat Cool Grass NIP/5 Heat Cod 6 W 128.09w 0.097 n 2A6 2.83 0 0 0 0 0 0 0 0 W 13A-4ocs 128.09w 0.143 0.097 n a 3.63 2A6 2.91 2.83 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 4A5.2om 4135.21m 0.550 0.540 a a 13.97 13.71 2723 29A1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-4ocs 4A5.2om 0143 0.550 a a 3.63 13.97 2.91 2723 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 465.2fm 0 540 a 13.71 19.52 0 0 0 0 0 0 0 0 11 DO 0390 a 9.90 1231 0 0 0 0 0 0 0 0 W 128.09w 0.097 s 2A6 283 0 0 0 0 0 0 0 0 Li13A- 40cs 4A5.2om 0.143 0 540 s s 3.63 13.71 291 14.76 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5.2om 0.550 s 13.97 1345 0 0 0 0 0 0 0 0 4A5-2omd 1213-0sw 0.580 0.097 s w 14.73 2.46 15.67 2,83 0 99 0 99 0 244 0 280 0 0 0 0 0 0 0 0 4A5.2om 4A5-2om 4A5.2om 0.540 0.5W 0 550 w w w 13.71 13.97 13.97 2941 2723 2723 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Vjl I--1a 13A-40cs 4A5.20m 4A5.2omd 0.143 OS50 0.580 w w w 363 13W 14.73 2.91 2723 1939 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0L-f q 12C-Osw 0.091 231 152 0 0 0 0 0 0 0 0 0 11D0 0390 n 990 1231 0 0 0 0 0 0 0 0 C 168.30ad 0.032 Oaf 1.76 68 68 55 120 18 18 14 31 F 19A-Obscp 0295 281 2.00 0 0 0 0 0 0 0 0 F 19C-19cscp 0.049 0.43 031 0 0 0 0 0 0 0 0 F 22A-cpm 1.180 29.96 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 27 2 Ermlope lossrgain 299 373 14 29 12 a) Infiltration 166 60 0 0 b) Room ventilation 0 0 1 0 0 13 Internalgacns: O=ipants@ 230 0 0 0 0 Applcancesb ter 0 0 Subtotal (lines 6 to 13) 465 434 14 29 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 14 28 7 15 14 Subtotal 479 461 21 44 15 Duct loads 1 10°/a 289/6 46 130 100/6 286/6 2 12 Total room load I I 5251 591 1 24 56 Air required (dm) 0 29 0 3 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. t- wrrlghteul'e- 2018-Apr•12081335 GcA Rlgtt-Sute®Unversal2018180.11 RSU16202 Page alc and EPL TempU_ot 068 Pembroke A LHG - W.np Calc - M18 House faces: W wrightsoft• Right-J® Worksheet Job: Entire House Date One Stop Cooling and Heating BY 7225 Sardscove CI. Srite 1. Winer Park, FL 32792 Phore: (407) 629.6920 Fax (407) 629 - 9307 Web: wwwOreSlopCoolirg corn License: CAC032444 Lot 068 Pembroke A LHG - W 09/14/2017 RI/MC/LM 1 Room name MTH 2 EVosed well 17.5 fi 0 (t 3 Room height 9.0 h heat/000l 90 It heaV000l 4 Roomdmensions 1.0 x 820 It 30 x 55 ft 5 Room area 82D IR 165 IF Ty Construction U-value Or HTM Area (tF) Load Area (IF) Load number BWMP-+) I or perimeter (11) Btuh) or perimeter (A) 8tuh) Heat Cool Gross NrPIS Heat Cool Gross N/P/S Heat Cool 6 W 128•096v 0.097 n 2.46 2.83 0 0 0 0 0 0 0 0 W 13A-4ocs 12B-09ry 0143 0.097 n a 3.63 2.46 2.91 2.83 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 4A5.2om 465.2Im 0.550 0.540 a a 1397 13.71 27.23 29.41 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-4ocs 4A5-2om 0143 0550 a a 3.63 13.97 2.91 27.23 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0G 485.21n 0.540 a 13.71 19.52 0 0 0 0 0 0 0 0 11D0 0.390 a 9.90 12.31 0 0 0 0 0 0 0 0 W 12B-09N 0.097 s 2A6 2.83 99 99 244 280 0 0 0 0 13A-40cs 0.143 s 3.63 2.91 0 0 0 0 0 0 0 0 4A5.2om 0.540 s 13.71 14.76 0 0 0 0 0 0 0 0 4A5.2om 0550 s 13.97 13.45 0 0 0 0 0 0 0 0 4A5-2omd 0.580 s 14.73 15.67 0 0 0 0 0 0 0 0 128-O9w 0097 w 2.46 2.83 59 55 134 154 0 0 0 0 4A5-2om 0540 w 13.71 29.41 4 0 53 115 0 0 0 0 4A5.2om 4A5.2om 0550 0550 w w 13.97 13.97 2723 2723 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V J V--C 13A-40rs 4A5.2orn 4A5.2omd 0.143 0.550 0.580 w w w 363 1397 14.73 2.91 2723 19.39 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0G 1-0 12C-Os6v 0.091 2.31 152 0 0 0 0 0 0 0 0 11 DO 0.390 n 9.90 12.31 0 0 0 0 0 0 0 0 C 168.30ad 0.032 081 1.76 82 82 67 144 17 17 13 29 F 19A-Obscp 0.295 2,81 2.00 0 0 0 0 0 0 0 0 F 19C-19cscp 0.049 0.43 0.31 0 0 0 0 0 0 0 0 F 22A-q3m 1.180 29.96 0.00 0 0 0 0 0 0 0 0 61 c) AED excursion 4 1-2 Errvelope loss/gain 498 698 13 27 12 a) Infiltration 264 96 0 0 b) Room ventilation 0 0 0 0 13 Internal gains'. Ooaipants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines6 to 13) 762 794 13 27 Less external load 0 0 0 0 Lesstransier 0 0 0 0 Redistribution 0 0 13 27 14 Subtotal 762 794 0 0 15 Duct loads 1 10% 280/ 73 223 10% 28% 0 0 Total room load 835 1017 0 0 Air required (dm) 0 49 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. I}rt- wr1-ghteoft- 2018-Apr-1208:1335 Aft"" "'-"^ Rigtt-Sute9Unversal201818.0.11 RSU16202 Page aic and EPL Temp1ot 068 PembrokeA LHG - W rip Catc - MIB House laoes: W wrightsoft• Right-J® Worksheet Entire House One Stop Cooling and Heating Job: Lot 068 Pembroke A LHG - W Date: 09/14/2017 By. RI/MC/LM 7225 Sardscove Cl Sute 1, Winter Pan4 FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCoollrgoom License: CAC032444 1 Room name BTH3 BED4 2 Elgwsedhell 10D It 26D ft 3 Room height 9,0 It healkool 90 It heatkool 4 Roomdmensons 1.0 x 585 It 1.0 x 158.8 ft 5 Room area 585 W 158,8 W Ty Construction U-value Or HTM Area (fF) Load Area OF) Load number BauhA +) Bl uh or perimeter (ft) BWh) or perimeter (ft) Bl uh) Heat Cool Gross NiP/S Heat Cool Gross NAS Heat Cool 6 W 128-09w 0.097 n 2A6 2.83 0 0 0 0 122 122 299 344 W 13A•4ocs 0.143 n 3.63 2.91 0 0 0 0 0 0 0 0 v 128.09w 0.097 a 2.46 2,83 0 0 0 0 0 0 0 0 11 4A5-2om 485.21m 0.550 0.540 a a 1397 1371 2723 29AI 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I—G L-a 13A-flocs 4A5.2om 0.143 0.550 a a 363 13.97 2.91 2723 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0G 4B5.21m 0S40 a 1371 19.52 0 0 0 0 0 0 0 0 11D0 0390 a 9.90 1231 0 0 0 0 0 0 0 0 W 12B-Osw 0.097 s 2A6 283 0 0 0 0 0 0 0 0 13A-40 s 0.143 s 363 291 0 0 0 0 0 0 0 0 4A5.2om 0.540 s 13.71 14.76 0 0 0 0 0 0 0 0 4A5.2om 0.550 s 1397 13.45 0 0 0 0 0 0 0 0 4A5.2omd 0.580 s 14.73 15.67 0 0 0 0 0 0 0 0 12B-Osw 0.097 w 2A6 2.83 90 84 207 238 113 98 240 276 4A5-2om 0.540 w 13.71 2941 0 0 0 0 0 0 0 0 4A5-2om 0.550 w 1397 2723 6 0 84 163 0 0 0 0 4A5.2om 0.550 w 13.97 2723 0 0 0 0 15 0 209 408 Val I—G 13A-40rs 4A5-tom 4A5-2omd 0.143 0.550 0 580 w w w 3.63 1397 14.73 2.91 2723 1929 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0G q--012C-09w 0.091 231 1.52 0 0 0 0 0 0 0 0 11 DO 03W n 9.90 1231 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 0AI 1.76 59 59 48 103 159 159 129 280 F 19A•Obsg1 0.295 221 2.00 0 0 0 0 0 0 0 0 F 19C-19sop 0049 0.43 031 0 0 0 0 0 0 0 0 F 22A-cprn 1.180 29.96 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 34 69 Ermlope loss(on 338 538 878 1377 12 a) Infiltration 151 55 392 142 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 AppliancesAother 0 1 0 Subtotal (lines 6 to 13) 489 593 1270 1749 Lessextemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redis9ibution 12 24 0 0 14 Subtotal 501 618 1270 1749 15 Duct loads 1 10% 28% 48 173 10% 281/6 122 491 Total room load 549 791 1392 2241 Air required ((*m) 0 38 1 0 108 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. w IghteoTt 2018-Apr-1208:1395 A&'. Rigtt-Srite®Universal 201818011 RSU16202 Page alc and EPL Temp1Lol068 PembrokeA LHG - W.np Calc = Mu8 House faces W wrightsoft' Right-J® Worksheet Entire House One Stop Cooling and Heating Job: Lot 068 Pembroke A LHG - W Date: 09/14/2017 By. RI/MC/LM 7225 Sardsmve Ct. SUte 1. Winer Park. FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCoolirg corn Licerse: CAC032444 1 Room name STR2 NEED 2 EVosed wall 0 It 335 A 3 Room height 90 It heatkool 90 8 heat/000l 4 5 Room dimensions Room area 1.0 x 755 tl 755 fF 1.0 x 2285 It 228.5 tF Ty Conshoon U-value Or HTM Area OF) Load Area (f) Load number BIWIL'F) Btu or perimeter (U) BWh) or perimeter (A) Btuh) Heat Cool Gross NAS Heat Cool Gross NAS Heat Cod 6 W 12&(k w 0.097 n 2A6 2.83 0 0 0 0 18 18 44 51 W 13A-40cs 0143 n 3.63 2.91 0 0 0 0 0 0 0 0 128.09w 0.097 a 2A6 2.83 0 0 0 0 122 103 252 290 4A5-2om 0.550 a 13.97 2723 0 0 0 0 15 0 209 408 11 485.26n 0.540 a 13.71 29.41 0 0 0 0 4 0 55 118 13A-flocs 0.143 a 3.63 2.91 0 0 0 0 0 0 0 0 4A5.2om 0.550 a 13S7 2723 0 0 0 0 0 0 0 0T0.5404B5.2fm a 13.71 19.52 0 0 0 0 0 0 0 0 11 DO 0 390 a 9.90 12.31 0 0 0 0 0 0 0 0 W 128.096v 0.097 s 2A6 2.83 0 0 0 0 162 162 399 458 13A•40cs 0.143 s 3.63 2.91 0 0 0 0 0 0 0 0 4A5.2om 0 540 s 13.71 14.76 0 0 0 0 0 0 0 0 4A5-2om OS50 s 13.97 13A5 0 0 0 0 0 0 0 0 4A5.2omd O580 s 14.73 15.67 0 0 0 0 0 0 0 0 12&09+v 0.097 w 246 2.83 0 0 0 0 0 0 0 0 4A5.20m 0.540 w 13.71 29A1 0 0 0 0 0 0 0 0 4A5.2om 4A5.2om OSM O550 w w 13.97 13.97 2723 2723 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 yl 13A-40s 0.143 w 3.63 2.91 0 0 0 0 0 0 0 0 4A5-2om 4A5.2omd 0.550 0.%0 w w 13.97 14.73 2723 19.39 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 q 12C•osw 0.091 2.31 1.52 0 0 0 0 0 0 0 0 1-0 11D0 0.390 n 9.90 12.31 0 0 0 0 0 0 0 0 C 168.30ad 0032 Ob1 1.76 76 76 61 133 229 229 186 403 F 19A-Obscp 0.295 2.81 2.00 0 0 0 0 0 0 0 0 F 19C-19scp 0.049 043 031 0 0 0 0 95 95 41 29 F 22A•cpm 1.180 29.96 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 8 34 Envelope loss/gain 61 125 1187 1723 12 a)' tr181tration 0 0 505 183 b) Room ventilation 0 0 0 0 13 Intemalgains: Omipantss@ 230 0 0 2 460 Applianoesbther 0 0 Subtotal (lines 6 to 13) 61 125 1692 2366 Less external load 0 0 0 0 Lessiransfer 0 0 0 0 Redistibution 61 125 9 19 14 Subtotal 0 0 1701 2385 15 Duct loads 1 109% 281/6 0 0 10'/a 289/6 1631 670 Total room load 0 0 180 3055 Air required (dm) 0 0 0 148 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrrlghtB4 - 2018-Apr-1208:1335 Aft Right-Sute®Unversal 2018 18 0 11 RSU16202 Page 5 alc and EPL Temp\Lot 068 Pembroke A LHG - W rtp Calc - MI8 Horse laoes: W wrightsoft• Right-J® Worksheet Job: Entire House Date: One Stop Cooling and Heating By. 7225 Sardscove CA. Suite 1. Winer Park FL 32792 Phone (407) 629 - 6920 Fax. (407) 629 - 9307 Web: wwwOneStopCoolirg com License: CAC032444 Lot 068 Pembroke A LHG - W 09/14/2017 RI/MC/LM 1 Room name GAME LDRY 2 Exposed wall 14.0 It 6.0 fi 3 Room height 90 8 heat/mol 93 Q heattool 4 5 Room dmensions Room area 1.0 x 227.8 ft 2278 tF 13.0 x 6.0 tl 780 fF Ty Cons"on U-value Or HTM Area ((F) Load Area (fF) Load number BtirhA -q Btuh4F) or perimeter ((t) BWh) or perimeter (i) Btuh) Heat Cool Cross N/P/S Heat Cool Gross NIPS Heat Cool 6 W 12B-09w 0.097 n 2A6 2.83 0 0 0 0 0 0 0 0 W 13A-40cs 0143 n 363 2.91 0 0 0 0 56 56 203 162 12B•09w 0.097 a 2A6 2.83 126 118 291 334 0 0 0 0 4A5.2om 0.550 a 13.97 2723 0 0 0 0 0 0 0 0 11 485.2hn 0.540 a 13.71 29AI 8 0 110 235 0 0 0 0 y! 13A•40cs 0.143 a 3.63 2.91 0 0 0 0 0 0 0 0 G 4A5-2om 485.21in 0.550 0.540 a a 13.97 13.71 2723 1952 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 DO 0 390 a 9.90 12.31 0 0 0 0 0 0 0 0 W 12B-09w 0.097 s 2A6 2.83 0 0 0 0 0 0 0 0 13A•4ocs 0.143 s 3.63 2.91 0 0 0 0 0 0 0 0 4A5-tom 0.540 s 13.71 14.76 0 0 0 0 0 0 0 0G 4A5-tom 0550 s 13.97 13A5 0 0 0 0 0 0 0 0 4A5.2omd 0.580 s 14.73 15.67 0 0 0 0 0 0 0 0 128.05w 0.097 w 2.46 2.83 0 0 0 0 0 0 0 0 4A5.2om 0.540 w 13.71 29A 1 0 0 0 0 0 0 0 0 4A5.2om OOM w 1397 2723 0 0 0 0 0 0 0 0 4A5-2om 0.550 w 13.97 2723 0 0 0 0 0 0 0 0 V+l 13A•4ocs 4A5.2om 4A5.2omd 0.143 Osw 0.580 w w w 3.63 13.97 14.73 291 27.23 1939 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0I :G' 12C-09w 0.091 231 1 S2 0 0 0 0 0 0 0 0 11D0 0.390 n 9.90 1231 0 0 0 0 0 0 0 0 C 168-30ad 0.032 OBI 1.76 228 228 185 401 0 0 0 0 F 19A•Obscp 0.295 2.81 2.00 28 28 79 56 0 0 0 0 F 19C-lgcscp 0049 0.43 031 38 38 16 12 0 0 0 0 F 22A•cpm 1.180 29.96 0.00 0 0 0 0 78 6 180 0 6 c) AED excursion 11 41 Emelope lose/gain 681 1026 382 122 12 a) Infiltration 211 77 93 34 b) Room ventilation 0 0 0 0 13 Internal gains: Ooapants@ 230 0 0 0 0 Applianoesrother 0 1 500 Subtotal (lines 6 b 13) 892 1103 476 656 Lem external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 33 67 223 172 14 Subbtal 924 1170 699 827 15 Duct loads 1 10°/a 289/6 89 329 139% 361h 92 294 Total room load 1013 1498 791 1122 Air required (dm) 0 72 0 54 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. P+A- wrlghteoTC- 2018-Apr-1208:1335 A Rigtrl-Sute®Uriversa120181&0.11 RSU16202 Page atc and EPL Temptol068 PembrokeA LHG - W np Celc - M18 House laces: W wrightsoft• Right-M Worksheet Job: Entire House Date: By: One Stop Cooling and Heating 7225 Sardsmve G. Sdte 1, Wirter Perk, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629.9307 Web: wwwOneStopCoolug mm License' CA0032444 Lot 068 Pembroke A LHG - W 09/14/2017 RI/MC/LM 1 Room name FLEX BED2 2 E111osW well 295 it 31.0 It 3 Room height 93 11 heatbool 93 it heaftol 4 5 Room area 13.0 x 125 It 1625 fF 13.0 x 185 fl 2405 IF Ty Construction U-value Or HTM Area (IF) Load Area (tF) Load number BWhAt *9 Btuh" or perimeter (A) Bah) or perimeter (II) Bluh) Heat Cool Goss N/P/S Heat Cool Goss NAS Heat Cool 6 W 12B-096v 0.097 n 2A6 2.83 0 0 0 0 0 0 0 0 W 13A-4o43s0.1 n 3.63 2.91 116 116 422 338 0 0 0 0 yl L-( 12B-09v 0.097 a 2.46 2,83 0 0 0 0 0 0 0 0 4A5.2om 0.550 a 13.97 2723 0 0 0 0 0 0 0 0 11 4B5.2fm 0540 a 13.71 29A1 0 0 0 0 0 0 0 0 h 13A-40s 0.143 a 3.63 2.91 121 105 380 304 0 0 0 0 4A5.2om 0 550 a 13.97 27.23 16 0 228 445 0 0 0 0 4B5.2fm 0540 a 13.71 19.52 0 0 0 0 0 0 0 0 11D0 0.390 a 9.90 12.31 0 0 0 0 0 0 0 0 W 128.09N 0.097 s 2A6 2.83 0 0 0 0 0 0 0 0 ty 13A-40s 0.143 s 3.63 2.91 37 37 135 108 172 156 565 453 4A5.2om 0.540 s 13.71 14.76 0 0 0 0 0 0 0 0 4A5.2om 0.550 s 13.97 13A5 0 0 0 0 16 13 228 220 4A5-2omd 0580 s 14.73 15.67 0 0 0 0 0 0 0 0 vh126.0sw 0.097 w 2.46 2.83 0 0 0 0 0 0 0 0 4A5-2om 0.540 w 13.71 29.41 0 0 0 0 0 0 0 0 4A5.2om 4A5.2om 0.550 0.550 w w 13.97 13.97 27.23 27.23 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Vy I 13A-4os 41A5-tan 4A5-2omd 0.143 0 550 0 580 w w w 363 13.97 14.73 291 2723 1939 0 0 0 0 0 0 0 0 0 0 0 0 116 0 48 68 0 39 248 0 707 199 0 9312C fj 12C-Osw 0.091 231 152 0 0 0 0 0 0 0 0 IIDO 02M n 9.90 1231 0 0 0 0 0 0 0 0 0C 16B-30ad 0.032 081 1.76 0 0 0 0 46 46 37 80 F 19A-Obscp 0295 2.81 2.00 0 0 0 0 0 0 0 0 F 19C-190scp 0049 0.43 031 0 0 0 0 0 0 0 0 F 22A•cpm 1.180 29.96 0.00 163 30 884 0 241 31 929 0 6 c) AED excursion 7 674 Emelope lossigain 2049 1203 2714 2557 12 a) Infiltraton 460 167 483 175 b) Room ventlation 0 0 0 0 13 Internal gains: Om ipanis@ 230 0 0 1 230 Appliancesrothar 1 0 0 Subtotal ( lines 6 to 13) 2509 1370 3197 2962 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 316 243 130 100 14 Subtotal 2825 1613 3327 3062 15 Dud loads 1 131/6 361/6 371 574 139/6 361% 437 1090 Total room load I I 1 3196 2187 3764 4152 Air required (dm) 0 106 1 0 201 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. tii- wrrlghtr9oft 2018-Apr-1208:1335 Af6K Right-Sute®Universal 2018180.11 RSU16202 Pagel alc and EPL Temp4.01068 PembrokeA LHO - W np Calc - IAM House faces: W wrightsoft• Right-J® Worksheet Job: . Entire House Date' One Stop Cooling and Heating By: 7225 Sardsmve CI Sure 1, Wlrler Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629. 9307 Web: wwwOneStopCoolirg corn Licerse: CA0032444 Lot 068 Pembroke A LHG - W 09/1412017 RI/MC/LM 1 Room name BTH2 CAFE 2 EVosed well 6.0 ff 215 It 3 Room height 93 It heat/cool 93 It heatl000l 4 5 Room dimensions Room area 9. 5 x 60 It 57.0 tF 13.0 x 85 It . 1105 IF Ty Conarumon U-% dlue of HTM Area (IF) Load Area (Ili Load number abiwIn B I or perimeter (f) Bwh) or perimeter (A) Bluh) Heat Cool Gross N/P/S Heat Cool Gross NIPS Heat Cod 6 W 1213- 0sw 0.097 n 2A6 2.83 0 0 0 0 0 0 0 0 W 13A•40cs 0.143 n 3.63 2.91 0 0 0 0 79 79 287 230 128.09w 0097 a 2.46 2.83 0 0 0 0 0 0 0 0 4A5-20m 0. 550 a 13.97 2723 0 0 0 0 0 0 0 0 11 485-21m O.540 a 13.71 29.41 0 0 0 0 0 0 0 0 t3A-4os 4A5- 2om 0. 143 0. 550 a a 363 13. 97 2. 91 2723 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N 485- 21n0.540 a 1371 19.52 0 0 0 0 0 0 0 0 IIDO 0290 a 9.90 12.31 0 0 0 0 0 0 0 0 W 12&09w 0. 097 s 2A6 2.83 0 0 0 0 0 0 0 0 13A-40s 4A5•2om 0.143 0.540 s s 3.63 1371 2. 91 14. 76 56 4 51 0 187 59 ISO 64 0 0 0 0 0 0 0 0 G 4A5. 2om 0.550 s 1397 13A5 0 0 0 0 0 0 0 0 4A5.2omd 0.580 s 1473 1567 0 0 0 0 0 0 0 0 12B-09w 0097 w 2.46 2.83 0 0 0 0 0 0 0 0 4A5.2om 0.540 w 13.71 29AI 0 0 0 0 0 0 0 0 05.2om 0550 w 13.97 2723 0 0 0 0 0 0 0 0 4A5.2om 0.550 w 13.97 2723 0 0 0 0 0 0 0 0 V+l 13A-4os 4AS-2om 4A5.2omd 0.143 0550 0. 580 w w w 3. 63 1397 14. 73 291 2723 1939 0 0 0 0 0 0 0 0 0 0 0 0 121 33 0 88 0 0 320 456 0 257 890 0 I---- 2 R 12C-09N 0. 091 231 1,52 88 88 204 134 0 0 0 0 I-D 11D0 0390 n 9.90 12.31 0 0 0 0 0 0 0 0 C 168.30ad 0. 032 081 1.76 0 0 0 0 III 111 90 195 F 19A•Obsoa 0295 2.81 2.00 0 0 0 0 0 0 0 0 F 19C•19scp 0. 049 0.43 031 0 0 0 0 0 0 0 0 F 22A-cpm 1. 180 29.96 0.00 57 6 ISO 0 111 22 644 0 61 c) AED excursion 1 14 1 1 266 Envelope loss/gain 630 333 1798 1838 12 a) Infiltration 93 34 335 122 b) Room ventilation 0 0 0 0 13 Internal gains: Oocupanls@ 230 0 0 0 0 Appliancesbltw 0 0 Subtotal ( lines6 b 13) 1724 367 12133 19% Less external load 0 0 0 0 Lessaansfer 0 0 0 0 Redistribution 223 172 0 0 14 Subtotal 947 539 2133 1959 15 Duct loads 1 13% 36% 124 192 13% 366/6 280 697 Total room load I 1071 731 2413 2657 Air required (dm) I 1 0 35 1 1 01 128 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r*- wrrlghtnof't 2018- Apr-1208:1335 Agh•Sule® Uriversal 201818. 0.11 RSU16202 Page alc and EPL Temp\ Lot 068 Pembroke LHG • W np Calc - Ml8 Horse laces: W wrightsoft• Right-J® Worksheet Entire House One Stop Cooling and Heating Job: Lot 068 Pembroke A LHG - W Date: 09/14/2017 By: RI/MC/LM 7225 Sardscove Ct. Sute 1, Wirler Park, A. 32792 Phone: (407) 629.6920 Fax: (407) 629 - 9307 Web, wwwOreStopCootirg.com License* CAC032444 1 Room name FAMILY Krr 2 Elposed well 24.0 It 13.0 ft 3 Room height 93 ft heat/000l 93 ft heaV000l 4 5 Room dimensions Room area 1.0 x 270.8 It 270.8 fF 13.0 x 13.0 It 169.0 IF Ty Construction U-value Or HTM Area (fF) Load Area (IF) Load number BL"Ir-n 801 or perimeter (ft) Bwh) or perimeter (ft) Bwh) Heat Cool Gross N/P/S Heat Cool Cross N/P/S Heat Cool 6 W W 128-096v 13A•4ocs 12B-Osw 0.097 0.143 0.097 n n a 2A6 3.63 2.46 283 291 2.83 0 0 0 0 0 0 0 0 0 0 0 0 0 121 0 0 121 0 0 439 0 0 352 0 11 4A5.2om 485.21n 0.550 0.540 a a 1397 1371 2723 29AI 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-40cs 4A5-20m 485.2hn 0.143 0.550 0.540 e a a 363 1397 13.71 2.91 2723 19.52 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G FL-_pG 11Do 12B-09w 0390 0.097 a s 990 2A6 1231 2.83 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0W 13A-40cs 4A5.2om 4A5.2om 0.143 0.540 0.550 s s s 3.63 13.71 13.97 2.91 14.76 QA5 88 0 0 40 0 0 147 0 0 117 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G IL----GG 4A5-2omd 128-Osw 4A5.2om 4A5.20m 4A5.2om 13A-4ofs 4A5-2om 4A5.2omd 12C•0sw 0.580 0.097 0.540 0.550 0.550 0.143 0.550 0.580 0.091 s w w w w w w w 14.73 2.46 13.71 13.97 13.97 363 1397 14.73 231 15.67 2.83 29.41 2723 2723 2.91 2723 19.39 1.52 48 0 0 0 0 135 33 0 0 48 0 0 0 0 102 0 0 0 707 0 0 0 0 371 456 0 0 752 0 0 0 0 297 890 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4! L:2r-C R D IIDO 0.390 n 9.90 12.31 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 OBI 1.76 187 187 152 329 59 59 48 103 F 19A-Obscp 0.295 2SI 2.00 0 0 0 0 0 0 0 0 F 19C•19cscp 0.049 043 021 0 0 0 0 0 0 0 0 F 22A•g3n 1.180 29.96 0.00 271 24 719 0 169 13 390 0 6 c) AED excursion 72 101 Envelope loss(gain 25U 2459 876 354 12 a) Infiltrabon 374 136 203 74 b) Room ventilation 0 0 0 0 13 Internal gains. Occupants @ 230 0 0 0 0 Appliancesiother 1 0 1 1200 Subtotal ( lines 6 to 13) 2926 2594 1079 1628 Less extemalload 0 0 0 0 Less trarder 0 0 0 0 Redislnbubon 223 172 93 72 14 Subtotal 3149 2766 1172 1699 15 Duct loads 1 13% 369% 413 984 13% 369% 154 605 Total room load I 3562 3750 1325 2304 Air required (dm) I 1 0 181 1 0 111 Calculabons approved byACCA to meet all requirements of Manual J 8th Ed. ri/- wrlghtmc re- 2018-Apr-1208:1335 Rigtl- Sute®Uriversal201818.0.11 RSU16202 Page alc ant EPL Temp\Lot 068 Pembroke LHG - W.rnp Catc - RE House faces: W wrightsoft• Right-J® Worksheet Entire House One Stop Cooling and Heating Job: Lot 068 Pembroke A LHG - W Date: 09/14/2017 By: RI/MC/LM 7225 Sardscove G. Sute 1 • Witter Park FL 32792 Phone: (407) 629.6920 Fax, (407) 629 - 9307 Web' wwwOreStopCoolirg com License: CAC032444 1 Room name STR 1 FOYER 2 Exposed well o n 7.0 n 3 Room height 93 IfheaVcool 93 n heavaool 4 5 Room dimensions Room area, 8A x 11.0 If 88.0 fF 10 x 1580 It 158.0 (F Ty Construction U-value Or HTM Area (IF) Load Area OF) Load number Bti1w+) Bojh" or perimeter (n) BWh) or perimeter (n) Bath) Heat Cool Gross N/P/S Heat Cool Gross PUPS Heat Cool 6 W W 12121-09w 13A•4ocs 12B-09w 0.097 0143 0.097 n n a 2A6 3.63 2A6 2.83 2.91 2.83 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 i 4A5.2om 485-2hn 0.550 0.540 a a 13.97 13.71 2723 29.41 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-40cs 4A5.2om 485-2an 0.143 0.5W 0.540 a a a 3.63 13.97 13.71 2.91 27.23 19.52 0 0 0 0 0 0 0 0 0 0 0 0 65 0 9 32 0 6 115 0 128 92 0 182 11DO 1213•09w 0390 0.097 a s 9.90 2A6 1231 2.83 0 0 0 0 0 0 0 0 24 0 24 0 238 0 295 0W 13A-40cs 4A5.2om 4AS-20(n 0.143 0.540 0.550 s s s 363 1371 13.97 2.91 14.76 13.45 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G II_--GG Vjl 4A5.2omd 0.580 0. 540 s w 14.73 2. 71 15.67 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5.2omA5-2ow 4A5.20m 4AS-20(n 13A•40cs 41A5-2om 4A5-2omd 12C-09N 0.540 0550 0.550 0.143 0-M 05w 0.091 w w w w w w 13.71 13.97 13.97 363 13.97 14.73 2.31 29.419A1 2723 2723 2.91 2723 19,39 1.52 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 116 0 0 0 0 0 0 98 0 0 0 0 0 0 225 0 0 0 0 0 0 148 IIF--G-- GG R L-D 11D0 02W n 9.90 12.31 0 0 0 0 19 19 185 230 C 168.30ad 0.032 0.81 176 0 0 0 0 0 0 0 0 F 19A-0bstp 0295 2111 2.00 0 0 0 0 0 0 0 0 F 19C•19tscp 0.049 0.43 031 0 0 0 0 0 0 0 0 F 22A-qxn 1.180 29.96 0.00 88 0 0 0 158 7 210 0 6 c) AED excursion 0 58 Envelope loss/gain 0 0 1101 890 12 a) Infiltration 0 0 109 40 b) Room ventilation 0 0 0 0 13 Intemalgains: Occupants@ 230 0 0 0 0 Applianoesb1her 0 1 0 Subtotal (lines 6 to 13) 0 0 1210 930 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 1210 930 14 Subtotal 0 0 0 0 15 Dud loads 131/6 36% 0 0 139% 36% 0 0 Total room load 0 0 0 0 Air required (dm) 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i ire.- wrrlghtaoft- 2018-Apr-1208:1395 Right-Shce®Uriversal201818011 RSU16202 Pepe 10 atc and EPL TemplLot 068 Pembroke A LHG - W.rnp Calc a MM Horse faces: W Duct System Summary Job: Lot 068 Pembroke ALHG -... WrIQht50ft' Y rY Date: 09/14/2017 Entire House By: RI/MC/LM One Stop Cooling and Heating 7225 Sardscove C1 Suts 1, Wirter Park FL 32792 Phore. (407) 629.6920 Fax: (407) 629 - 9307 Web: wwwOreStopCoolirg.com license: CAC032444 Project• • For: Park Square Homes 3972 Night Heron Dr., Sanford, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.170 / 0.170 in H2O 0.222 in/100ft 0 cfm 153 Supply Branch Detail Table Cooling 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.170 / 0.170 in H2O 0.222 in/100ft 1367 cfm Name Design Btuh) Htg cfm) Clg cfm) Design FR Diam in) H x W in) Duct Mal Actual Ln (it) Ftg.Egv Ln (it) Trunk BED2 c 4152 0 201 0.222 8.0 Ox 0 VIFx 46.4 107.0 st2 BED3 c 2132 0 103 0.293 6.0 Ox 0 VIFx 21.0 95.0 st1 BEN c 2241 0 108 0.281 6.0 Ox 0 VIFx 21.0 100.0 SO BTH2 c 731 0 35 0.237 4.0 Ox 0 VIFx 36.4 107.0 st2 BTH3 c 791 0 38 0.284 4.0 Ox 0 VIFx 19.8 100.0 st1 CAFE c 2657 0 128 0.249 6.0 Ox 0 MR 29.8 107.0 st2 FAMILY c 3750 0 181 0.248 8.0 Ox 0 VIFx 29.9 107.0 st2 FLEX c 2187 0 106 0.282 6.0 Ox 0 VIFx 13.4 107.0 st2 GAME c 1498 0 72 0.327 5.0 Ox 0 MR 8.9 95.0 st1 KfT c 2304 0 111 0.274 6.0 Ox 0 VIFx 22.3 102.0 st2 LDRY c 1122 0 54 0.284 4.0 Ox 0 VIFx 12.9 107.0 st2 MBED c 3055 0 148 0.288 7.0 Ox 0 VIFx 18.1 100.0 st1 MBTH c 1017 0 49 0.283 4.0 Ox 0 VIFx 20.3 100.0 st1 Mrol c 56 0 3 0.293 4.0 Ox 0 VIFx 16.1 100.0 SO MWIC c 591 0 29 0.307 4.0 Ox 0 VIFx 15.8 95.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type cfm) cfm) FIR fpm) in) in) Material Trunk SO Peak AVF 0 550 0.281 700 12.0 0 x 0 VinlFlx st2 PeakAVF 0 817 0.222 764 14.0 0 x 0 VinlFlx 1 * wrightsoft- 2018-Apr-1208:1396 AM. W.• «, .w Righi-Suta®Uriversal201818.0.11RSU16202 Pagel atc anJ EPL TeffoNLot 068 Pembroke A LHG - W np Calc = M18 Horse laces. W Return Branch Detail Table Name Grille Size (in) Htg cfm) Clg cfm) TEL ft) Design FR Veloc fpm) Diam in) H x W in) Stud/Joist Opening (in) Duct Mad Trunk rb3 Ox 0 0 1367 0 0 0 0 Ox 0 MFx wrightsoft- 2018•Apr•1208.1336 k- • . , .. Righl•SULOUriversa12018 18 0.11 ASU16202 Page 2 19Malc and EPL Temptol068 Pembroke LHG • W.np Calc . fvt18 Fbtse faces W Static Pressure and Friction Rate Job: Lot 068 Pembroke ALHG -... Wf IQht50 Date: 09/14/2017 Entire House ey: RI/MC/LM One Stop Cooling and Heating 7225 Sardsoove Ct. Sute 1, Winer Park, FL 32792 Phors: (407) 629 - 6920 Fax: (407) 629.9307 Web: wwworeStopCoolirg oom Licerse• CAC032444 Project• • For: Park Square Homes 3972 Night Heron Dr., Sanford, FL AvailablePressure Heating Cooling in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0 0 Heatexchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 0.34 Total• Supply Return ft) ft) Measured length of run -out 38 0 Measured length of trunk 9 0 Equivalent length of fittings 107 0 Total length 153 0 Total effective length 153 It Heating Cooling in/100ft) in/100ft) Supply Ducts 0.222 > 0.18 0.222 > 0.18 Return Ducts 0.222 > 0.18 0.222 > 0.18 Supply 4X=35, 11 M=20,11 H=7,11 G--5,11 G=5,1 A--35: TOtalEL=107 Return TotalEL=0 wrightsoft- 2018-Apr-12 08.1336 W •..w.. ..., .., Right-Sute8Udversa1201818011 RSU16202 Page 1 alc and EPL Templot 068 PembrokeA LFIG - W W Calc = MA Howe faces: W Level 1 8 IOX6 CAFE 128 cfm I 41) I ie7 i FAMILY Iq> T90 \111 4 \ I 1016 10x10 t 111 fm 6 Iic7 181 cfm I v KIT BE02 4b, 19J 201 cfm 8XA LORY OV ViW cfm 1 I I 10 x 1 9u STR1 I r « __ j db by r ISup Rise 14 19v , BTH2 j--[b 35 cfm 8X4 J tee[ 1 9 GARAGEI A3T Job #: Lot 068 Pembroke A LHG - W Performed by RUMC/LM for: Park Square Homes 3972 Night Heron Dr. Sanford, FL. 4 6 10X6 3 106 cfm FLEX 7r( R . = i EN 1= 1 I ` U I I i i EF1 = 50 CFM Fan EF2 = 80 CFM Fan EF3 = 110 CFM Fan EFL1 = 50 CFM Fan EFL2 = 80 CFM Fan EFL3 = 110 CFM Fan VTR = Vent to Roof VTW = Vent to Wall DV = Dryer Vent RV = Range Vent Lineset Chase — — Condensate — - — Thermostat 18/8 OT SRB = Small Reduction Box LRB = Large Reduction Box FBB = Feld Built Box One Stop Cooling and Heating 7225 Sandscove Ct. Suite 1 Winter Park, FL 32792 Phone: ( 407) 629 - 6920 Fax: (407) 629 - 9307 wwwOneStopCooling. com ale: 1 : 95 Page 1 Right- SuitA Universal 2018 18, 0.11 RSU16202 2018- Apr-12 08:14:44 p% Lot 068 Pembroke ALHG - Wrup 1 N Level 2 i MWIC i 8X4 ' MBTH 8X4 29 cfm vU-0=8fH3 38 cfm BED4 8X4 8' 30X18 RA 9 cfm I 3 c m I STR2 ., 367--cftn j-- JOX6 T01 \ 10x10 108cfm I -, 4 4 „I I %1 1 Sup Riser ID i 148cfm 12x1 10X8 7 Ph M 13 FBB1 5" ft 12x12 x12 1i'10 1ox6 4OX6 _ 1Q3 cfm 72 cfm \ I MBED GAME BED3 0 6 EFt = 50 CAM FandbiIEF2 = 80 CRAA Fan i i I EF3 = 110 CFM Fan EFL1 = 50 CFM Fan EFL2 = 80 CFM Fan EFL3 = 110 CFM Fan VTR = Vent to Roof ZONE DAMPER VNJ = Vent to Wall DV = Dryer Vent 14" DAMPER 1 ST FLR RV = Range Vent 12" DAMPER 2ND FUR = Lineset Chase — — 12" BYPASS = Condensate — - - Thermostat 18/8 Q SRB = Small Reduction Box LRB = Large Reduction Box FBB = Feld Built Box Job #: Lot 068 Pembroke LHG - W One Stop Cooling and Heating Scale: 1 : 95 Performed by RVMC/LM for: Page 2 Park Square Homes 7225 Sandscove Cl. Suite 1 Right -Suite® Universal2018 3972 Night Heron Dr. Winter Park, FL 32792 18.0.11 RSU16202 Sanford, FL Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 2018-Apr- 12 08:14.45 wwAtOneStopCooling.com ...out 068 Pembroke ALHG - Wnrp r Se43(Y' C"Y-dy t 311Z M," I'l.'t Sl'V'viCfS . RECORD COPY DESCRIPTION AS FURNISHED: Lot 68 , WYNDHAM PRESERVE, as recorded in Plat Book 81, Pages 93 through 102 of the Public Records of Seminole County, Florida. PLOT PLAN FOR/CERTIFIED TO: Park Square Enterprises, LLC (a Delaware Corporation); Winderweedle, Haines, Word & Woodman, PA; Attorneys' Title Insurance Fund; Bank of America P j8 _ ,q C9 REMAINDER OF LOT 6 PALMER'S SUBDIVISION PLAT BOOK 2, PACE 41 G I I In S $ _--- S 00 . 0' E ----- NIr\! . _ _ PATE ' 60. 00' Ok to construct single family home 10' FENCE ESMT. with setbacks and impervious area — — — — — — — — — — — — — — shown on plan. 34 • o % " P- tm\ov oke - A L cL- 39.15' 39.16, ry 6 LOT 68 I 10.00' LANAI 10.00' 12.3 00 v CO PROPOSED RESIDENCE v 4 PEMBROKE - A LOT 69 Co Cq GARAGE LEFT O ( Z 7! N AIC a. 6.50' 13.3' 10.00' ENTRY c 9.0' 10.00' 20.0' DRIVE 39.87' 25.2 ' 5.20' I10' UTIL. ESMT. P.C.67375_------------ SETBACKS AS FURNISHED FRONT 25'(•) REAR a 20' SIDE - 5' (40' LOT) 7.5' (60' LOT) 10' (75' LOT) SIDE STREET - 25' (60' EL 75' LOT) 15' (40' LOT) 25' FRONT SETBACK CAN BE REDUCED TO 20' ON CERTAIN LOTS. NO MORE THAN 2) IN SUCCESSION AT 20' AND A MINIMUM OF (2) IN SUCCESSION AT 25' PROPOSED - nNSHED SPOT GRADE ELEVATIONS PER DRAINAGE PLANS PROPOSED DRAINAGE FLOW 14jLOTGRADINGTYPEAMOD PROPOSED F.F. PER PLANS - 24.7' WALK R S 000 > 6' 57" E (a.a.) 60. 00' NIGHT HERON RRI VE 50' PRIVATE RIW) LOT 67 PLOT PLAN ONLY PLOT PLAN AREA CALCULATIONS NOT A SURVEY TOTAL LOT AREA 7,141 t SQUARE FEET FLATWORK ONIOFF LOT a TOTAL t SQUARE FEET FLATWORK DRIVE 4031 110- 513 t SQUARE FEET FOUNDATIONIPAD 1,752 t SQUARE FEET WALKS 49I 300- 349 t SQUARE FEET REAR PATIO 119 t SQUARE FEET DECK E FEET SOD 4.7091 250 - 4,959 t SQUARE FEET POOLT ECKCH NIA t SQUARE FEET NOTE. FRONT SIDEWALK AND STREET LOCATION TAKEN FROM PLANS PROVIDED BY CLIENT • NOT FIELD VERO'IED - CRUSL'NML'YL'R-SCOTT L.J4 ASSOC, INC. - LANI SURVEYORS LCGCND - L[GCND " 5400 E. COLONIAL DR. ORLANDO, FL. 32807 (407)-277-3232 FAX (407)-658-1436 P PLAT ILL POINT ON LINE moms, rIP. FIELDIRON TIP[ TVP. ll.t. IIM TYPICALPOINTOr REVERS[ tugvATlRt[ POINT OF COMPOUND CIAVATURC I. THE IRNOERSIONED DOES HEREBY CERTRY TNAr TIRS SURVEY MEETS THE STANDARDS of PRACTICE SET FORM or IRE FLORIDA BOARD OF IRCA IRON R00 CONCRCTC MONUMENT NAIL RADIAL PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER Si-17 FLORIDA ADNWISTRAIIVE CODE PURSUANT TO SECTION 472.027. FLORIDA STATUES SCT IA. 1/P• IA •/IU 43I4 NR NOM-RADIAL 1. UNLESS EMBOSSED W/M SU/f1'EYOR'S AGNAlURE AND ORIGTNU. RAISED SEAL 1M15 SURVEY AIAP OR CONES ARE NOT VAL10. CC. R[COVCRCD C P. CAP. w1TMtSS POOR J. nO SURVEY WAS PREPARED FROM TIRE INFORMATION MRMSNEO TO THE SURVEYOR. THERE M4Y BE OTHER RESTIUCRONS PELB. ro1NT Or B[GWUNG CALCULATED OR EASOdEN S THAT AFFECT TTOS PROPERTY. PL.C. MINT Or COMM[NC[MCNt CENTCRLNE Rllrr. BSL PERMANENT RCFCRCNCC IOIIUMINT FINISHED ROOK ELEVATION BUILDING SETIACK LINE 4. NO LU19ERORWN9 aIPROYEMCNTS HAVE BEEN LOCATED UNLESS OTHERWISE SHOWN. Q THIS SURKY IS PREPARED FOR THE SOLE BENEFIT OF THOSE CERTIFIED TO AND SNOULO NOT BE RELIED UPON BY ANr ORICR ENTRY. NLOR/W NAIL L DISK RIGMT-OF-WAY Ul BENCHMARK DINENS06 SHOWN FOR THE LOCATION Of IMPROVEMENTS NEREON SHOULD NOT BE USED TO RVC0MSTRUCr BOUNDARY LINES. CSMT. CASEMENT I.B. DASC BEARING 7. SEARUM ARE BASED ASSUMED OAIVM AND ON THE LINE SHOWN AS BASE BEARING (&B.) ORAIK DRAINAGE ELEVATION$ IF SHORN. ARE BASED ON NATIONAL GEOOERC VERTICAL DATUM of it". UNLESS onanKE NOTED. UTIL. UTLLITYGNAWLINK FENCE 9. CERIIFICATE OF AUTINOMZ,ITION No. 459& wart. • WOOD FENCE CI'S BLOCKCPICI'B • POINT W CURVATURE P.T. • roINT tJr TANGENC7 DESC. DESCRIPTION R • RADIUSARCLACNWTH DELT C . CHORD C.S. CHORD BLARING MG . NATURAL GRADE NORTH CERTIFIED BY.• SCALE I- I• - 20 - I ORAWN BY: ••• I 00"l MA 9 PLOT PLAN 04-OJ-2018 2023-18 THIS BUILOINWROPERTY DOES NOT UE MITHIN THE ESTABLISHED 100 YEAR FLOOD PLANE AS PER FIRM• ZONE •K MAP 112117CO090 F (09-28-07) TOM RUSENM R, R.L.S. 1 4714 JAMES SCOrr. .L.S / 4801 10 RECORD COPY Filename: PARK SQ PEMBROKE.rrr Lighting and Small Appliance/Laundry Circuits Floor Area SmAppNo LaundNo Line Neutral 2380 2 1 Lighting Summary Standard 6,024 6,024 Optional 11,640 6,024 Ranges & Ovens Range No. No? Nameplate Line Neutral 1 1 8000 2 0 0 3 0 0 Range/Oven Summary Standard 6,400 4,480 Optional 8,000 4,480 Dryers-----------------------------------------------------SANF9Rf)- ------ Dryer No. No? Nameplate Line Neutral O AARTM 1 1 5000 2 0 3 0 #1 8- 1 9 19DryerSummaryStandard5,000 3,500 Optional 5,000 3,500 Heating and Cooling: Actual Number = 1 Name M? Ph No Amps Volts VA HP Line Neutral 1 M 1 1 27.0 240 6,480 0 1 M 1 1 2.0 240 480 0 1 M 1 1 5.0 240 1,200 0 1 1 1 1 27 240 1 6,480 0 Heat/Cool Summary Standard 14,640 0 Optional 14,640 0 Fixed Appliances: Actual Number = 6 Name M? Ph No Amps Volts VA HP Line Neutral bISP 1 1 120 600 600 600 DISH 1 1 120 1200 1,200 1,200 MICRO 1 1 120 1200 1,200 1,200WATERHEATER1118.5 240 4,440 0OPTPOOL11102402,400 0OPTPOOLHEAT11312407,440 0 Fixed Appliance Summary Standard 12,960 2,250 Optional 17,280 2,250 Other Appliances: Actual Number = 0 Name M? Ph No Amps Volts VA HP Line Neutral Other Appliance Summary Standard 0 0 Optional 0 0 25- of Max Motor: Line is Std Only; Neutral for Both Maximum Phase Amps Volts 1 27 240 Heat/Cool Phase Amps Volts 1 27 240 Fixed Appl. Phase Amps Volts 0 Other Appl. Phase Amps Volts 0 Max Motor Summary Standard Only 1,620 0 SUMMARY Standard Line Neutral Total Total = 46,644 16,254 Maximum Amperage = 194 68 Service Voltage = 240 Service Phase = 1 Optional Line Neutral Total Total = 37,408 16,254 Maximum Amperage = 156 68 Service Voltage = 240 Service Phase = 1 RECORD COPY Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. MiTek a RE: PSQ2382A - Park Sq/ PEMBROKE 2382E-TRAY MiTek USA, Inc. Site Information: 66r904 Parke East Blvd. Customer Info: PARK SQUARE HMS. Project Name: PSQ2382A Model: PEMBROgp a236Z33fA10 4115 Lot/Block: 68 Subdivision: WYNDHAM PRESERVE 60' Address: 3972 NIGHT HERON DR. City: SANFORD State: FLORIDA Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 140 mph Roof Load: 40.0 psf Floor Load: 55.0 psf This package includes 47 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date I No. I Seal# Truss Name I Date 1 T13712206 4CJ1 4/6/18 112 1 T13712217 B4 4/6/18 2 T13712207 4CJ3 4/6/18 113 T13712218 C1 4/6/18 3 T13712208 4CJ5 4/6/18 14 T13712219 C2 4/6/18 4 T13712209 4.17 4/6/18 15 T13712220 CJ1 4/6/18 5 T13712210 4KJ7 4/6/18 16 T13712221 CJ3 4/6/18 6 T13712211 Al 4/6/18 17 T13712222 CJ5 4/6/18 7 T13712212 A2 4/6/18 18 T13712223 D1 4/6/18 8 T13712213 A3 4/6/18 119 IT13712224 D2 4/6/18 9 T13712214 81 4/6/18 20 T13712225 D3 4/6/18 10 T13712215 82 4/6/18 21 T13712226 D4 4/6/18 11 IT13712216 IB3 4/6/18 122 1 T13712227 E1 4/6/18 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Mid -Florida Lumber Acquisitions, Inc.. Truss Design Engineer's Name: Lee, Julius My license renewal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 111111/// o.IUS CF i iLENS. No 34869 oi Q= 1) STATE OF •:/ Julius Lee PE No.34869 MITek USA. Inc. FL Coil 6634 6904 Parke East BNd..Tempa FL 33610 Oats: April 6,2018 Lee, Julius I of 2 RE: PSQ2382A - Park Sq/ PEMBROKE 2382B-TRAY Site Information: Customer Info: PARK SQUARE HMS. Project Name: PSQ2382A Model: PEMBROKE 2382 - A Lot/Block: 68 Subdivision: WYNDHAM PRESERVE 60' Address: 3972 NIGHT HERON DR. City: SANFORD State: FLORIDA No. Seal# Truss Name Date 23 T13712228 E2 4/6/18 24 T13712229 E3 4/6/18 25 T13712230 E4 4/6/18 26 T13712231 F1 4/6/18 27 T13712232 F2 4/6/18 28 IT13712233 F3 4/6/18 29 IT13712234 I F4 4/6/18 30 IT13712235 I F5 4/6/18 31 IT13712236 I F6 4/6/18 32 IT13712237 I F7 4/6/18 33 IT13712238 I F8 4/6/18 34 IT13712239 I F9 4/6/18 35 IT13712240 I F10 4/6/18 36 IT13712241 IF11 4/6/18 37 IT13712242 I F12 4/6/18 38 IT13712243 I F13 4/6/18 39 IT13712244 IG1 4/6/18 40 IT13712245 G2 4/6/18 41 IT13712246 JG3 4/6/18 42 IT13712247 IG4 4/6/18 43 IT13712248 JH1 4/6/18 144 IT13712249 I J7 14/6/18 1 45 IT13712250 JKJ7 4/6/18 46 IT13712251 1-1 4/6/18 47 IT13712252 1-2 4/6/18 2 of Job Truss Truss Type Oty Pry Park Sq/ PEMBROKE 23828-TRAY T13712208 PS02382A 4CJ1 JACK 4 1 job Reference (optional) Mid-Flonda Lumber, Bartow, FL. S.130 s Mar 11 2018 MiTek Industries, Inc. Fri Apr 6 11:47:46 2018 Page 1 10:2 6TByhmA9cROtSuo2pKVvy3nnN-wAzrecOtEOU3MwOtenf/1T0kPgwANOEOUonrpA_zTS18 1-0-0 1.0.0 1-0-0 1-0-0 2x4 = Scale - 1.6 1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) Udefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 006 Vert(LL) -0.00 5 >999 240 MT20 244/190 TCOL 10.0 Lumber DOL 1.25 BC 0 01 Vert(CT) -0.00 5 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 000 4 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Wnd(LL) -0.00 5 >999 360 Weight: 5lb ' FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No 2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purims BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 10.0-0 oc bracing. REACTIONS. (lb/size) 3=10/Mechanical, 2-130/0-7-8, 4=- 1 Mechanical Max Horz 2=35(LC 6) Max Uplift 3=-4(LC 10), 2=92(LC 6). 4=-l(LC 1) Max Grav 3=11(LC 3), 2=130(LC 1), 4=11(LC 6) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7.10; Vuh=140mph (3-second gust) Vasd=108mph, TCOL=4.2psf; BCOL-3.Opsf; h=15f1; Cat II; Exp B; Encl.. GCpl=0.18; MWFRS (envelope) gable end zone and C-C Extenor(2) zone;C-C for members and forces 6 MWFRS for reactions shown; Lumber OOL=1.60 plate grip OOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2, 4. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lae PE No. 11069 Wall USA, Inc. FL Cert 6614 6904 Parke East Blvd. Tampa FL 931110 Date: April 6,2018 WARNING - Verify design parameters and READ NOTES ON TNIS AND INCLUDED affrEK REFERENCE PAGE Mll•7472 rev. 101034015 BEFORE USE. Design valid for use only with MITak® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use. the budding designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chard members only. Addnionai temporary and permanent bracing AiYl iTek' Is always required for stabddy and to prevent collapse with possible personal Injury and property damage. For general guidance regarding ins fabrkatron. storage. delivery. erection and bracing of trusses and truss systems, see ANWMII Quality Criteria, OSS4 2 and SCSI Building Component 69N Ps" East SM. Sefoty Informslion available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandra. VA 22314. Tampa, FL 36610 Job Truss Truss Type 0ty Ply Perk Sq/ PEMBROKE 2382B•TRAY T13712207 PS02382A 4CJ3 JACK 4 1 Job Reference (optional) Mid-Flodda Lumber, Banow, FL. S.130 s Mar 11 2018 MiTek Industries, Inc. Fri Apr 6 11:47:47 2018 Page 1 ID:Z_6TByhmA9cROt5uo2pKVvy3nnN-OMXOryRV7kcvv_4 3CUMErhzup4EL6tUeISXJiOzTS1A 1.0-0 3.0-0 1.0-03-0-0 2x4 = 3: 3- Scale = t 9 4 LOADING ( psf) SPACING- 2-0-0 CSI. DEFL. in loc) Udell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.08 Vert(LL) -0 00 7 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.01 4-7 >999 180 BCLL 00 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MP Wind(ILL) 0.00 7 >999 360 Weight: 11 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3.0.0 oc purtins BOT CHORD 2x4 SP No 2 BOT CHORD Structural wood sheathing directly applied or 10.0-0 oe bracing. REACTIONS. ( lb/size) 3=70/Mechanical, 2=186/0.7-8, 4=38/Mechanical Max Horz 2=64(LC 6) Max Uplift 3=-43(LC 10). 2--98(LC 6), 4=-4(LC 10) Max Grav 3=70(LC 1), 2=188(LC 1). 4=51(LC 3) FORCES. ( lb) - Max. Comp./Max Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsh h-15ft; Cat. II; Exp B; Encl., GCpi= 0.18, MWFRS (envelope) gable end zone and C-C Extenor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber OOL=1.60 plate grip DOL=1 60 2) This truss has been designed for a 10.0 pal bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20 Opsf on the bottom chord in all areas where a rectangle 3-6-0 tell by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) 3, 2, 4. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 34869 kliTek USA, Inc. FL Cert 6634 6204 Parke East Blvd. Temps FL 33610 Date: April 6,2018 QWARNINO • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rar. 1"3/2015 BEFORE USE. Design valid tot use only with Mf rekO Connectors. This design Is based only upon parameters shown, and Is for an Individual building component. not a truss system. Before use, the building designer must vent' the applimbidty, of design parameters and properly Incorporate this design Into the overall building design. 8radng Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addalortal temporary and permanent bracing MiTek• Is always required for stability and to prevent Collapse with possible personal Injury and property damage. For general guidance regarding the fabrication. storage• delivery. erection and bracing of trusses and truss systems, sea ANSVTPII Quality Criteria, OS049 and SCSI Building Component 6204 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lae Street, Suite 312. Alexandria, VA 22314 Tamps. FL 36810 Job Truss Truss Type City Park Sq/ PEMBROKE 23828•TRAY JPly T13712208 PS02382A 4CJ5 JACK 4 1 b Reference (optional) Mid-Flodda Lumber, Bartow. FL. 8.130 s Mar 11 2018 MiTek Industries, Inc. Fri Apr 6 11:47:48 2018 Page 1 ID:2 ST8yhnuA9cRO15uo2pKVvyUnN-IY5b21R7m2kmcDZGIBuTOuV0IUYvrKkjx6GtEUTS19 1-0-0 54W 1-0-0 5-0-0 Scale = 1,12 7 2x4 = 5-0-0 LOADING (psf) SPACING- 2.0-0 cSl. DEFL. in loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.31 Ven(LL) -0.03 4-7 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.24 Vert(CT) -0O6 4-7 >983 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 100 Code FSC2017frP12014 Matrix -MP Wjnd(LL) 003 4-7 >999 360 Weight 17 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No 2 TOP CHORD Structural wood sheathing directly applied or 5.0-0 oc purlins. BOT CHORD 20 SP No 2 BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing REACTIONS. ( lb/size) 3=126/Mechanical, 2=264/0-7-8, 4=65/Mechanical Max Horz 2=94(LC 6) Max Uplift 3=79(LC 10), 2-119(LC 6). 4=5(1-C 10) Max Grav 3=126(LC 1). 2=264(LC 1). 4=89(LC 3) FORCES. ( lb) - Max. Comp./Max. Ten - All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vutt=140mph (3-second gust) Vasd=108mph: TCDL=4.2psf, BCDL=3.Opsf; h=15ft; Cat. It: Exp B. Encl.. GCpl= 0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone,C-C for members and forces 6 MWFRS for reactions shown; Lumber DOL=1 60 plate grip DOL-1.60 2) This [fuss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at lolnt(s) 3, 4 except (lt=lb) 2= 119. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 34663 HTO USA, Inc. FL Cart 6034 004 Parke East Blvd. Tampa FL 33610 Data: April 6,2018 QWARNINO • Verity, design parameters and READ NOTES ON IMS AND INCLUDED MITEK REFERENCE PAGE SIX7413 fev. 1"JIMIS BEFORE USE. Design valid for use only with MITakaD connectors. This design Is based only upon parameters shown, and Is tot an Individual building component, not a truss system. Before use, the budding designer must varity the applicability of design parameters and property Incorporate this design Into the overall building design Sractng Indicated Is to prevent buckling of Individual truss wab and/or chord members only. Additional temporary and permanent bracing MiTek' IsalwaysrequiredforstabilityandtopreventcollapsewdhpossiblepersonalInjuryandproperlydamage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, tore ANSVrPl1 Quality Criteria. OSS-ea and SCSI Building Component 6904 Parke East BIM Safety Information available from Truss Plate Institute. 218 N. Lae Street. Sune 312. Nexandda. VA 22314 Tamps, FL 36610 Job Truss Truss Type Oy Pry Perk Sty PEMBROKE 23828•TRAY 1 T13712209 PS02382A 4J7 JACK 14 1 Job Reference(optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Mar 11 2018 MTek Industries. Inc. Fri Apr 6 11:47 48 2018 Page 1 ID Z 6TByhnW9cROt5uo2pKVvy3nnN-tY5b21R7m2k=DZGIBuTOuVw9UTirKkixBGtEtzTS19 1-0.0 7-0-0 r 1 0.0 7-0-0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) Udell L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.69 Vert(LL) 010 4-7 802 240 TCDL 10 0 Lumber DOL 1 25 SC 0.51 Vert(CT) 0 24 4-7 347 180 BCU- 0.0 Rep Stress Incr YES WS 0.00 Horz(CT) 000 2 n/a n/a SCOL 10.0 Code FBC2017fTP12014 Matrix -MP Wind(L-) 013 4-7 633 360 LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No 2 REACTIONS. ( lb/size) 3=182/Mechanical, 2=342/0-7-8, 4=91/Mechanical Max Horz 2=124(LC 6) Max Uplift 3=115(LC 10). 2=-143(LC 6), 4-6(LC 10) Max Grav 3=182(LC 1). 2=342(LC 1). 4=127(LC 3) FORCES. ( lb) - Max. Comp./Max Ten. - All forces 250 (lb) or less except when shown. Scale - 1.16 2 PLATES GRIP MT20 244/190 Weight, 23 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0.0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult-140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf, h=15ft; Cat. II; Exp B, Encl., GCpl= 0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone,C-C for members and forces 8 MWFRS for reactions shown; Lumber OOL=1 60 plate grip DOL=1 60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20 Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except at=lb) 3= 115, 2-143. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. M$69 MiTek USA, Inc. FL Cert 6634 8904 Parke Ent Blvd. Tampa FL 33410 Date: April 6,2018 WARNING . Verify design parameters and READ NOTES ON Ties AND INCLUDED aeTEK REFERENCE PAGE af/67413 rev. 1111014015 BEFORE USE. Design valid for use only with MITek® connectors This design Is based only upon parameters shown, and is for an Individual building component, not a truss system Before use, the building designer must venly the applicability of design parameters and property Incorporate this design Imo the overall building design. Bracing Indicated Is to prevent buckling of Individual tone web and/or chord members only. Addalonal temporary and permanent bracing M iTek' Is always required for stability and to prevent collapse w4h possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Cnteds, OS049 and SCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute. 216 N. Lee Street, Suite 312. Alexandds. VA 22314. Tampa, FL 38610 Job Truss Truss Type Ory Park Sq/ PEMBROKE 2382E-TRAY 113ty T13712210 PS02382A 4KJ7 JACK 2 1 job Reference Mid -Florida Lumber, Bartow, FL. 8.130 s Mar 11 2018 MTek Industries, Inc. Fn Apr 6 11:47.49 2018 Page 1 I D:Z_6TByhmA9cR0t5uo2pKVvy3nnN-LlfzGeSIXLsdEN8SJvPiw626%WOagftAmOOnJzTS 18 1-5-0 54.9 9.10.13 15-0 - 54.9 444 ' Scale = 120 7 3x4 = 5 54-9 444 LOADING (psi) SPACING- 2-" CSI. DEFL. in loc) Udell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 058 Vert(LL) 0.03 6-7 999 240 MT20 244/190 TCOL 100 Lumber DOL 1.25 BC 0.57 Vert(CT) 0.09 6-7 999 180 BCLL 0.0 ' Rep Stress Incr NO WB 047 Horz(CT) 0.02 5 Me n/a BCDL 100 Code FBC2017frPI2014 Matrix -MR W1nd(LL) 005 6-7 999 360 Weight 40 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No 2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=245/Mechanical, 2=416/0.7$, 5=398/Mechanical Max Horz 2-188(LC 4) Max Uplift 4=-221(LC 4). 2=226(LC 4). 5=168(1_C 8) FORCES. (lb) - Max Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1126/516 BOT CHORD 2-7-655/1088. 6-7=-655/1088 WEBS 3-7=0/268, 3-6=-1137/685 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-3-4 oc puriins. BOT CHORD Structural wood sheathing directly applied or 7-3-5 oc bracing. NOTES- 1) Wind, ASCE 7-10: Vult=140mph (3-second gust) Vasd=108mph; TCDL-4.2psf; BCDL=3.Opsf, h=15ft, Cat. 11, Exp 8; Part. Encl., GCpi=0.55: MWFRS (envelope) gable end zone; Lumber DOL=1.60 plate grip DOL=1 60 2) This truss has been designed for a 10.0 psi bottom chord live load nonconcurreni with any other live loads 3) ' This truss has been designed for a live load of 20.Opsf on the bottom,chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4-221, 2=226, 5=168. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead r Roof Live (balanced) Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2-60 Trapezoidal Loads (plf) Vert: 2-0(F=30, B=30)-to-4=-148(F--44, 8=44), 8=0(F=10, 8=10)-to-5=49(F=15, B=15) This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Las PE No.14669 MiTek USA, Inc. FL Cert 9834 904 Perks Eat Blvd. Tampa FL 13610 Date: April 6,2018 Q wARN/NG . Varlly design parameters end READ NOTES ON r70S AND INCLUDED AUTEK REFERENCE PAGE 0110-703 rev. f"VW16 BEFORE USE. Oesign valid far use only with M(Tak® Connectors. This design Is based only upon parameters shown, and Is for an Individual building Component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent bucking of individual truss web andfor chord members only Additional temporary and permanent bracing M iTek' Is ahvays required for stablldy and to prevent Collapse with possible personal Injury and pmparty, damage Far general guidance regarding the labricatlon. storage, delivery, erection and bracing of trusses and truss systems, see ANSIRPII Duality Criteria, OSS49 and SCSI Building Component 6904 Pence East Slyd. Safely Information available from Truss Plata Institute. 218 N Lea Street, Suite 312, Alexandria, VA 22314 Tampa, FL 36610 Job Truss Truss Type Ply Park Sq/ PEMBROKE 23828-TRAYOty T13712211 PS02382A Al HIP 1 1 Job do al Mid -Florida Lumber, Bartow, FL 7.0.0 4 00 12 2.9.14 ' 2-9-14 S.130 s Mar 11 2018 MTek Industries, Inc. Fri Apr 6 11:47:50 2016 Page 1 I D:4XOfOoTTPdL7G6iOkGU6m6v3nnf-PxDMT_TNIf_Ur)QetcwxTJbCNH3iJ010POIzJlzTS 17 2-9-14 ' 2.9.14 ' 7-0-0 2x4 II 5x6 = 5x8 2x4 II 7x12 4x8 = 7x12 2x4 II 5x8 5xS = 3 4 5 6 7 8 9 10 11 12 Scale - 1.68.4 to 10x10 = 4x8 = 74 = 10x10 = ex10 = 7x8 = 4xS _ 5x6 = LOADING (psq SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 125 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 •Except• 3-8,8-12: 2x6 SP No.1 D BOT CHORD 2x6 SP No.1 'Except' 15-18,18-20: 2x6 SP No.2 WEBS 2x4 SP No.3 *Except* 6.19,6-17,9.17,9-16: 2x4 SP No 2 CS1. DEFL. in loc) Well L/d PLATES GRIP TC 0.96 Vert(LL) -0.25 19 >999 240 MT20 244/190 SC 0.93 Vert(CT) -0.48 17-19 >678 180 WB 0.89 Horz(CT) 009 16 n/a n/a Matrix -MR Wind(LL) 0.28 19 >999 360 Weight, 236 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Structural wood sheathing directly applied or 4-2-4 oc bracing. WEBS 1 Row at midpt 9-16 REACTIONS. (lb/size) 2-1829/0-7-8, 16=4765/0-7-8, 13=77/0.7-8 Max Horz 2=52(LC 12) Max Uplift 2=-743(LC 4), 16=-2133(LC 5), 13--198(LC 7) Max Grev 2=1837(LC 19), 16=4832(LC 17), 13=102(LC 20) FORCES. (lb) - Max Comp /Max. Ten - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4878/1993, 3.4=-4594/1925, 4-5=-5086/2105, 5-6=5086/2105, 6-7=-2170/823, 7-9=2170/823, 9-10=-2015/4826, 10-11=2015/4826, 11-12--257/1084, 12-13=-301/1161 BOT CHORD 2-20=-1849/4657, 19.20=-2073/5139, 17-19-1639/4029. 16.17=1039/483, 15-16=-2732/1100.13-15=-1078/319 WEBS 3-20=-158/790,4-20=-788/349. 5-19=-433/285.6.19=-458/1310, 6-17=-2214/1036, 7-17=-461/309, 9.17=-1411/3670, 9-16=-4361/1898, 10.16=-668/390, 11-16=-2639/1285, 11-15=1099/2396, 12-15=1195/580 NOTES- 1) Unbalanced roof live loads have been considered for this design 2) Wind. ASCE 7-10, Vult-140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf; h=15ft, Cat. II, Exp B; Encl.. GCpi=O 18, MWFRS (envelope) gable end zone, porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) 'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (It=lb) 2=743, 16=2133, 13=198. 7) Girder carries hip end with 7-0.0 end setback. 8) Hanger(s) or other connection device(s) shell be provided sufficient to support concentrated load(s) 560 lb down and 266 lb up at 33-0-0, and 560 lb down and 266 lb up at 7-0-0 on lop chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 4 V1 IN d This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lss PE No. 34669 WTek USA, Inc. FL Cart 0634 204 Parke East Blvd. Tampa FL 31610 Data: April 6,2018 AWARNINO . Verify deals. panmefors and READ NOTES ON THIS AND INCLUDED AUTEK REFERENCE PAGE M/l-7473rev. 1"nOtS BEFORE USE. Oaslpn valid for use only with MITeMb connectors. This design Is based only upon parameters shown, and Is for an Individual bullding component, not a truss system Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design Bracing Indicated Is to prevent buckling oftndlvldual truss web and/or Cord members only. Additional temporary and permanent bracing M iTek• Isalwaysr*qulred for Validity and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, *(action end bracing of busses and truss systems, see ANSVTPII Quality Criteria, OSS49 and SCSI Building Component 69N Parke East BIM Safely Information available from Truss Pate Institute, 216 N Lee Street, Suite 312. Alexandds, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382&TRAY T13712211 PS02382A Al HIP 1 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Mar 11 2018 MTek Industries, Inc. Fri Apr 6 11.47:50 2018 Pape 2 ID:4XOfOoTTPdL?G6iOkGU6m6y3nnf-pxDMT TNI(UrXietcwxTJbCNH3iJ010POIzJlzTS17 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase-1 25 Uniform Loads (plf) Vert 1-3=60, 3-12=-126(F--66), 12-14=60, 2-13=-42(F--22) Concentrated Loads (lb) Vert: 3=-385(F) 12=385(F) AWARNING - Verify design parameters and READ NOTES ON TMS AND INCLUDED MITEK REFERENCE PAGE MX74" rev. 11100312015 BEFORE USE. Oeslgn valid for use only with MITeklR connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not buss system. Before use, the building designer must verity the applicability of design parameters and property Incorporate this design Into the overall buadtng design. Bracing indicated Is to prevent buckling of Individual Truss web and/or chord members ores. Additional temporary and permanent bracing Welk' Is always (squired for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrkstion. storage, delivery, erection and bracing of trustee and truss systems, sae ANSVTPII Quality Criteria, OSS49 and BCSI Building Component 6904 Parks East Blvd Safety information available from Truss Plate Institute, 218 N Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/ PEMBROKE 2382&TRAY T13712212IPS02382AA2HIP11 b Reference (optional) Mid -Florida Lumber, Bartow. FL. 8.130 s Mar 11 2018 MTek Industries, Inc. Fri Apr 6 11.47:51 2018 Page 1 ID:4XO(OoTTPdL7G6jOkGU6m6y3nnf-H7mkhKU73z6LThlgRKRA7X7ROhQd2ZhAe4VXrB2TS16 1 4-10.14 9-0-0 12.7.12 178 9 22.5 7 27 4 4 31-0-0 35 1-2 40-0-0 1 0 4-10.14 4-1.2 3-7-12 4-10-13 4-10-13 4-10.13 3.7.12 4-1.2 4.10.14 4 00 12 5x6 = 1.Sx4 II 5x5 = 3x8 = 1 5x4 11 5x8 = 5 6 7 a 9 Scale - 168 7 Z'__V 3x8 = 19 18 30 = 3x8 17 18 15 30 = 3x8 = 1.50 II to 14 13 axe 3x4 ma 34 = 12V cs LOADING (psQ SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.69 Vert(LL) 016 19-22 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 125 BC 0.88 Verl(CT) 0 36 19-22 >907 180 BCLL 0.0 Rep Stress Incr NO w8 0.50 Horz(CT) 005 14 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MR Wind(LL) 0.13 18 >999 360 Weight. 198 lb FT - 0% LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-6-2 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 6.0-0 oc bracing. WEBS 20 SP No.3 WEBS 1 Row at midpt 7-14 REACTIONS. ( lb/size) 2=967/0-7-8, 14=2193/0-7-8, 11=160/0-7-8 Max Horz 2=65(LC 10) Max Uplift 2=397(LC 6). 14=787(1.0 7), 11-143(LC 11) Max Grav 2=981(LC 21), 14=2193(LC 1), 11=202(LC 22) FORCES. ( lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2.3=-2263/961, 3.4=-1833/742, 4-5=-1742f749, 5.6=-1742/749, 6-7=-1299/551, 7- 8=593/1642, 8-9= 59311642. 9-1 0=-327/86 1. 10.11=-201/645 BOT CHORD 2-19=-835/2132, 18-19=-58711712, 17-18=-445/1326, 13-14=-798/404, 11-13=-583/220 WEBS 3-19=-463/293, 4-19=-60/386, 5.18=258/149, 6.18=-218/519, 6-17=583/307, 7- 17=-526/1310, 7-14=20531820, 8-14=292/164, 9-14=-1196/474, 9.13=661397, 10- 13=-534/321 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vutt=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL-3 0psf; h=15tt; Cat II; Exp B; Encl., GCpi= 0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1 60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10 0 psf bottom chord live load nonconcurrent with any other live loads. This item has been 5) ' This truss has been designed for a live load of 20.0psf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide fit between bottom electronically signed and willthechordandanyothermembers6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) sealed by Lee, Julius, PE 2= 397, 14=787, 11=143. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Les PE No. UU9 Wok USA, Inc. FL Cart 8034 8904 Parks East Blvd. Tampa FL 33810 Date: April 6,2018 AWARNING • Verify design pammefars and READ NOTES ON INS AND INCLUDED AaTEN REFERENCE PAGE AN-7473 rev. 1003/2015 BEFORE USE. Design valid for use only with MITek® connectors This design le based only upon parameters Mown, and Is for an IndNMual building component, not the applicability of design parameters and property Incorporate this design Into e overall atrusssystemBeforeuse, the building designer must verity m bultdtng design. Bracing indicated Is to prevent budding of Individual truss web andlar chord members only. Additional temporary and permanent bracing M iTe k' IsallaysrequiredforstabaAy, and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, we ANSIRPI1 Quality Cdterta, OS849 and BCSI Building Component 8904 Puke Fast Blvd. Safety Inform ldan available from Truss Plate InsillNs, 216 N Lee Strati, Suite 312. Alexandria, VA 22314 Tampa, FL 36810 Job Truss Truss Type oty Ply Park Sq/ PEMBROKE 23828-TRAY T13712213 PSO2362A A3 HIP 1 1 Reference (optional) Mid-Flonda Lumber, Bartow, FL. 1-0 5-10.14 11-0-0 17-0.9 05.10-14 5-1-2 6.0.9 5x8 = 3x4 = 4. 00 12 4 5 f' lM' dC 13u s Mar t i zinc Nu t elt ID: 4XO(OoTTPdL9G6iOkGU6m6v3nnf-IKK6u 5. 1-2 1. 5x4 II 5x8 = 6 7 Inc. rn Apr is 11:41:3Z ZU115 rage 1 rtt_ 1yPYkgan5nmlYJskE4NezTS15 Scale - 1:68 7 17 16 15 14 13 12 11 US = 1.5x4 II 3x4 = 30 = 5x6 MT20HS = US = 30 = 1 5x4 I I 3x6 = LOADING ( psf) TCLL 20.0 TCOL 10.0 BCLL 00 ' BCDL 10.0 SPACING- 2-0-0 Plate Grip OOL 1.25 Lumber OOL 1.25 Rep Stress Incr NO Code FBC2017rrPI2014 CSI. TC 0.77 BC 0.82 WB 0.40 Matrix - MR OEFL. V@ri( LL) Vert( CT) Horz( CT) Wind( LL) in ( loc) UdeO Ud 0. 45 13-15 >999 240 0. 92 13-15 >524 180 0. 21 9 n/a life 0. 48 13-15 >999 360 PLATES GRIP MT20 2441190 MT20HS 187/143 Weight: 195 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No 2 TOP CHORD Structural wood sheathing directly applied or 2-2-1 oc purlins. BOT CHORD 2x4 SP No.1 BOT CHORD Structural wood sheathing directly applied or 4-11-4 oc bracing. WEBS 2x4 SP No.3 REACTIONS. ( lb/size) 2=1660/0-7-8, 9=1660/0.7-8 Max Horz 2-78(LC 10) Max Uplift 2--636(LC 8), 9=-636(LC 7) FORCES. ( lb) -Max. Comp /Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=4327/1786, 3-4=-3719/1561, 4-5=4271/1824, 5-6=4269/1823, 6.7=4269/1823, 7- 8-371911562. 8-9=432 7/ 1786 BOT CHORD 2-17=-1608/4062, 16-17-1608/4062, 15-16=-131313498. 13-15=1616/4271, 12- 13=1313/3499, 11-12=1608/4062, 9-11=160814062 WEBS 4-16=-85/ 401, 7-12=-85/402, 5.15=426/244, 6-13=3681222. 3-16=623/319, 4-15=-396/1037, 7-13=-394/1034,8-12=-622/319 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7- 10; Vult-140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. it: Exp B; Encl , GCpi=0.18: MWFRS ( envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1. 60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. This Item has been 6) ' This truss hasbeendesignedforaliveloadof20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tell by 2-0-0 wide will fit between the bottom chord and any other members. electronically Signed and 7) Provide mechanical connection ( by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) sealed by Lee, Julius, PE 2=636, 9=636. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 30869 MITek USA, Inc. FL Cart 6636 62U Parka East Blvd. Tampa FL 33610 Data: April 6,2018 O WARNING • Vartly design parameters and READ NOTES ON TNS AND INCLUDED MITEK REFERENCE PAGE AVI.7473 rev. l""015 BEFORE USE. Design valid for use only with MITak® connectors This design Is based only upon parameters shown, and is for an IndMdual building component, not a truss System. Before use, the building designer Oust verity the applicability of design parameters and property InCorporsto this design Into the overact building design. Brating Indicated Is to prevent budding of Individual truss web and/or chord members only. Additional temporary and permanent bracing ivi iTek' Is always required forstabilityandtopreventcollapsewanpossiblepersonalInjuryandpropertydamage. For general guidance ragardmg the fabrication, storage, dativery, arealon and bradng of trusses and truss systems, sae ANSVrPl1 Quality Criteria, OS842 and SCSI Building Component 6904 PsAe East Blvd. Safety Information available from Truss Plata Institute, 218 N Lea Street, Suite 312. Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type 0ty Pry Park Sq/ PEMBROKE 2382E-TRAY T13712214IPS02382AB1GABLE11 Job Reference bin al Mid -Florida Lumber, Barlow. FL 8 130 s Mar 112018 MTek Industries, Inc. Fri Apr 6 11:47:53 2018 Page 1 ID:(E1iSoL4yGPugoUalTHtlpy3oM_ DWuU6?VGbaM3i?SDYITe5yDw5VJ5Wa1SS0 ew4zTS14 1-0-0 10-0-0 20-0-0 21-0-0 1-0-0 10-0-0 10.0-0 1-0-0 Scale = 1:36.4 4x4 = 1ri 3x4 = 22 21 20 18 16 17 16 15 14 3x4 = I.Sx4 II 1.5x4 II I.Sxa II 1.Sx4 II Sx5 = 1.5x4 II 1.5x4 II 1.5x4 II 1.Sx4 II Plate Offsets (X Y)— 12:0.0-0 0-0-0I 116:0-2-8 0-3-01 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Grip OOL 1.25 TC 0.10 Ven(LL) -0.00 13 n/r 180 MT20 244/190 TCOL 100 Lumber DOL 1 25 BC 0.05 Vert(CT) -0.00 13 n/r 80 BCLL 0.0 ' Rep Stress Incr NO WB 0.06 Horz(CT) 0.00 12 n/a n/a SCOL 100 Code FBC2017/TPI2014 Matrix-R Weight: 101 Ill FT = Oe.S LUMBER- BRACING - TOP CHORD 2x4 SP No 2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 10.0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 20.0-0. lb) - Max Horz 2=107(LC 11) Max Uplift All uplift 100 Ill or less et joints) 12,2,19.20.21. 22. 17, 16, 15, 14 Max Grav All reactions 250 Ill or less at joint(s) 12. 2, 18, 19, 20, 21, 22. 17. 16, 15. 14 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind, ASCE 7-10: Vult-140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=15ft: Cat It: Exp B, Encl.. GCpi=0.18; MWFRS (envelope) gable end zone and C-C Extertor(2) zone,C-C for members and forces & MIAFRS for reactions shown; Lumber OOL-1.25 plate grip DOL=1.25 3) Truss designed for wind bads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ill uplift at joint(s) 12, 2, 19, 20, 21, 22, 17. 16, 16. 14. 9) Truss is designed with, and confirms to the 2007 Florida Building Code w/2009 supplements This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lot PE No.11669 MiTek USA, Inc. FL Cart 6611 6904 Parke East Blvd. Tampa FL 3300 oats: April 6,2018 AWARNING • Verily design parameters and READ NOTES ON TMS AND INCLUDED MITEN REFERENCE PAGE Ml4T4T3 rev. 100M016 BEFORE USE. Design valid for use only with MITek® connectors. This design Is baud only upon parameters shown, and Is for an Individual building component, not a truss "am. Before use, the bulding designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only Additional temporary and permanent btadng M iTe k' Is always required for stabildy and toprevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication. storage, delivery, ruction and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, OSS49 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plata Institute, 216 N Lee Sweet, Suite 312, Alexandria, VA 223 m. Tampa, FL 36810 Job Truss Truss Type Oy Ply Park Sq/ PEMBROKE 2382B-TRAY T13712215 PS02382A B2 OUEENPOST 4 1 b Reference (ontionall Mid-Flodda Lumber, Barlow, FL. 1.0-0 ' 5-3-3 8.130 s Mar 112018 MiTek Industries, Inc. Fri Apr 6 11:47:54 2018 Page 1 to(E1jSoL4yGPugoUalTHtlpy3oM-hiSSJLWUMuUwK81P6S td917LuTTf ucK2jBSWzTS13 4x4 = 4.8-12 5.3.4 ' 1-0-0 ' Scala = 1:35.3 g 4x4 = Sx8 = 4x4 = 10-0-0 20." 10.0-0 10-0.0 Plate Offsets (X.Y)- 18.0.4-0.0-3-01 LOADING (psQ SPACING- 2.0-0 CSI. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.45 Vert(LL) -0.15 6-8 >999 240 MT20 244/190 TCDL 10.0 Lumber OOL 1.25 BC 0.75 Vert(CT) -031 6-8 >753 180 SCLL 00 Rep Stress Incr NO WB 0 21 Horz(CT) 0.03 6 n/a n/a SCOL 10.0 Code FBC2017/TPI2014 Metrix-R Wind(LL) 0.04 2-8 >999 360 Weight: 89 lb FT - 04A LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing direly applied or 4-10-2 oc purlins. BOT CHORD 2x4 SP No.1 BOT CHORO Structural wood sheathing directly applied or 9-11-14 oc bracing. WEBS 2x4 SP No.3 REACTIONS. ( lb/size) 6-854/0-7-8, 2=854/0.7-8 Max Horz 2=107(LC11) Max Uplift 6=275(LC 11), 2=-275(LC 10) FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1255/570, 3-4=-957/443, 4-5=957/443, 5-6=1256/570 BOT CHORD 2-8=-391/1068, 6-8=391/1069 WEBS 3-8=-332/257, 4-8=182/561, 5.8=-333/258 NOTES- ( 6) 1) Unbalanced roof live loads have been considered for (his design. 2) Wind, ASCE 7-10: Vuk=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCOL-3.0psf; h=15ft; Cat. If: Exp B. Encl., GCpi= 0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber OOL=1 25 plate grip DOL-1.25 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6= 275, 2=275. 6) Truss Is designed with, and confirms to the 2007 Florida Building Code w/2009 supplements. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lae PE No. W9 MITek USA, Inc. FL Cert 6634 IM Preside East Blvd. Temps FL 33610 Date: April 6,2018 AWARNING • Veft design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M/I.7473 rar. /dU3126ta BEFORE USE. Design valid for use only with M(Takm Connectors This design is based only upon parameters snown, and is for an Individual building component, not a truss system. Before use, the building designer must vanty the applicability of design parameters and property Incorporate mis design into the overall budding design Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Adddbn it temporary and permanent bracing M iTek' isalwaysrequiredtarstabitay, and to prevent collapse with possible personal Injury and property damage. For general guidance regarding der fabrbalon. storage. delivery, erechon and bracing of trusses and truss systems, see ANSVTPII Quality Cottons. OSS49 and SCSI Building Component 6904 Parke East Blvd. safely Information available from Truss Plate Institute. 21a N Lee Street, Suite 312. Maxendda. VA 22314 Tampa, FL 38810 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382E-TRAY T13712216 PS02382A 83 OUEENPOST 2 1 b Reference (optional Mid-Flodde Lumber, Bartow, FL. 9 4-8-12 4x4 = 8 130 s Mar 11 2018 MiTek Industries, Inc. Fri Apr 6 11:47,55 2018 4-8-12 4x4 = 4x4 US = 1-0.0 ' Scale = 1.35.2 10-00 20-0.0 10-60 10-0-0 Plate Offsets (X Y)- f7.0.4-00.3.01 LOADING ( psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.48 Vert(LL) -0.15 5-7 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.75 Vert(CT) -0.32 1-7 >738 180 BCLL 0.0 ' Rep Stress Incr NO W8 0.21 Horz(CT) 0.03 5 n/a n/a BCDL 10.0 Code FBC2017frPI2014 Matrix-R Wind(LL) 0.06 1-7 >999 360 Weight: 88 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-8-7 oc purlins. BOT CHORD 2x4 SP No.1 BOT CHORD Structural wood sheathing directly applied or 9-7-14 oc bracing. WEBS 2x4 SP No 3 REACTIONS. ( lb/size) 5=856/0-7-8, 1-772/0-7-8 Max Horz 1=-115(LC 11) Max Uplift 5=-276(LC 11). 1=235(LC 10) FORCES. ( lb) - Max. Comp./Max Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2-1268/588, 2-3=-964/453, 34=964/452, 4-5=-1262/579 BOT CHORD 1-7=-411/1083, 5.7=-399/1074 WEBS 2-7=-343/271, 3-7-193/564, 4-7=-333/257 NOTES- ( 6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind, ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL-3 Opsf; h=15ft; Cat II, Exp B; Encl.. GCpi= 0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.25 plate grip DOL=1.25 3) This truss has been designed for a 10 0 psf bottom chord live bed nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tell by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ut=lb) 5= 276,1=235 6) Truss is designed with, and confirms to the 2007 Florida Building Code w12009 supplements. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Les PE No. 34669 MiTek USA, Inc. FL Cart 66U 6904 Parka Ent Blvd. Tampa FL 33610 Date: April 6,2018 AWARNING - Verify design parameters and READ NOTES ON Tiffs AND INCLUDED wrEK REFERENCE PAGE 11111.7473 rw. 1"3/2015 BEFORE USE. Design valid for use only with Mfrekm connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design Bra" Indicated Is to prevent buckling of IndlAdwl truss web and/or chord members only. Additional temporary and permanent bracing MiTek* IsalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalInjuryandpropertydamage. For genanl guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and buss systems, sea ANSVrP11 Quality Criteria, 058419 and SCSI Building Component 6904 Parka East Blvd Safety Information available from Truss Plate Institute, 210 N. Lae Street. Suite 312, Mexarorle, VA 22314 Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382B-TRAY T13712217 PS02382A 84 HOWE 1 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL 8.130 a Mar 11 201 B MiTak Industries, Inc Fn Apr 6 11.47:56 2013 Page 1 ID:70b5f8LijaXlSy2mbBo7a 1 y3oLz-e5adk 1 Y8u1/Ie2SAoD11 LiarNUi8zjlmvnMCIXPzTS 11 3 7-0 6 7-11 10 0 0 13.4.8 18-SO 20.0 0 3.71 3.0.8 3-4.8 3.4.6 3.0-8 3.7-0 Scale = 134 9 4x4 = I$ i1xB ' 74 = 7xB = 70 = 34 LOADING (psf) TCLL 200 TCDL 100 SCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017/TPI2014 CS1. TC 0.34 8C 0.81 WB 0 83 Matrix-R OEFL. In Vert(LL) -004 Vert( CT) -0.17 Horz( CT) 0.05 Wind( L-) 0.03 loc) Well L/d 9 > 999 240 10 > 999 180 7 n/a n/a 10 > 999 360 PLATES GRIP MT20 244/190 Weight: 119 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-9 oc purlins BOT CHORD 2x6 SP No.2 BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. ( lb/size) 1-1752J0-7-8, 7=1266/0.7-8 Max Horz 1=-96(LC 9) Max Uplift 1=-237(LC 8), 7=-237(LC 9) FORCES. ( lb) - Max Comp./Max. Ten -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3391/428, 2-3=32811355, 3-4=1967/307, 4-5=1968/307, 5-6=2267/356, 6- 7=2396/429 BOT CHORD 1-10=429/2950. 9-10=299/2911, 8-9=211/1996, 7-8=334/2076 WEBS 4-9--18911533, 5-9=379/185, 5.8=33/258, 3.9=-16521185, 3.10=-32/1582 NOTES- ( 10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vuh=140mph (3-second gust) Vasd-108mph, TCDL=4.2psf; BCOL-3.Opsf; h=15f1; Cat. II; Exp B; Encl., GCpi= 0.18; MWFRS (envelope) gable end zone; Lumber DOL=1.25 plate grip DOL=1.25 3) Concentrated loads from layout are not present in Load Case(s): #3 Dead + Uninhabitable Attic Without Storage; #4 Dead + 0.6 MWFRS Wind (Pos Internal) Left; #5 Dead + 0.6 MWFRS Wind (Pos Internal) Right; #6 Dead + 0.6 MWFRS Wind (Neg Internal) Left; # 7 Dead + 0.6 MlAFRS Wind (Neg Internal) Right; #8 Dead + 0.6 MWFRS Wind (Pos. Internal) 1 at Parallel, #9 Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel; #10 Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd Parallel; #11 Dead + 0.6 MWFRS Wind Pos. Internal) 4th Parallel; #12 Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: #13 Dead + 0.6 MWFRS Wind (Neg Internal) 2nd Parallel; #18 Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Lel); #19 Dead + 0.75 Roof Live (bal.) + 0.75(0.6 This item has been MWFRSWind (Neg. Int) Right); #20 Dead + 0.75 Roof Live (ball + 0 75(0.6 MWFRS Wind (Neg. Int) 1st Parallel); #21 Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel). electronically Signed and 4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. Sealed by Lee, Julius, PE 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0-0 wide using a Digital Signature. will rd between the bottom chord and any other members. Flirted COpI@S Of this 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at Joint(s) except (jt=lb) document are not considered 1=237, 7=237. 7) Girder carries tie -In span(s) 2-8-0 from 6-6-12 to 13-6-4 signed and sealed and the 8) Hanger(s) or other connection device(s) shall be provided sufficient to support Concentrated load(s) 1543 lb down at 6.7-8, and 147 signature must be verified lb down at 13.4-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. On any electronic Copies. 9) In the LOAD CASE($) section, bads applied to the face of the truss are noted as front (F) or back (8). Julius Lee PE No. 34669 10) Truss is designed with, and confirms to the 2007 Florida Building Code w/2009 supplements MiTek USA, Inc. FL Cart 6634 LOAD CASE(S) Standard 6904 Parka East Blvd. Tempe FL 13610 Date: April 6,2018 WARNING - Vw* deslgn parameters and READ NOTES ON THIS AND INCLUDED aOTEK REFERENCE PA E 4111147471 rev. 1&0312015 BEFORE USE. Oesign valid for use only with MITek® connectors. This design Is based only upon parameters Shawn, and Is for an Individual building component, not a truss system Before use, the building designer must verify the applicability of design paramaten and property Incorporate this design Into the overall building design Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek' IsalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalInjuryandpropertydamageForgeneralguidanceregardingthefabrication, storage, delivery, ateaton and bracing of trusses and thus systems, see ANSIfTPII Ousiity Criteria, OSS42 and SCSI Building Component 6904 Parke East BM safety Information available from Truss Plate InslltNe, 218 N Lee Street, Suds 312. Alexandria, VA 22314. Tamps, FL 36610 Job Truss Truss Type Oty Ply Park Sql PEMBROKE 2382B•TRAY T13712217 PS02382A 84 HOWE 1 1 Job of o Banal Mid -Florida Lumber. Bartow, FL. a 130 s mar 11 2ul tl Nil tax industries, Inc. rn Apr a 11 A V00 2UIO rape z ID:7Ob5f8LrjaXlSy2mb8o7a 1 y3oLz-e5adk 1 Y8uMeZSADDt 1 LiarNUl8zilmvnMCIXPzTS 11 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert. 1-4=60, 4-7=-60, 1-10=20, 8-10--21(F=-1), 7-8=-20 Concentrated Loads (lb) Vert: 8=33(F) 10-1429(F) AWARNING - Vartly desrgn parameters and READ NOTES ON IMS AND INCLUDED WTEK REFERENCE PAGE at11.7473 rev. 10N14013 BEFORE USE. Oestgn valid for use only with MITek® connectors This design Is based only upon parameters Shown, and Is for an individual building component, not a truss system Before use, the building designer must verify the applkablitty of design parameters and property Incorporate this design Into the overall bullNnq design Bracing Indicated Is to prevent buckling o11ndlNdual was web and/or chard members Dory. Addalonal temporary and permanent Waring Welk' k' la always rer ulred for stability and to prevent Collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage• delivery, eredbn and bracing of trusses and truss systems. us ANSIRPII Duality Criteria, OS1349 and SCSI Building Component e904 Parke East Blvd. Safety Information available from Truss Plate Inslaute, 218 N. Lee Street. Suite 312. Alexandria. VA 22314 Tampa, FL 36610 Job Truss Truss Type 0ty Ply Perk Sq/ PEMBROKE 2382E-TRAY T13712218 PS02382A C1 GABLE 1 1 Job Referenceo tional Mid•Flonda Lumber, Bartow, FL. 6.130 s Mar 112018 MiTek Industries, Inc. Fri Apr 6 11:47:57 2018 Page 1 10:70b5f8LilaXlSy2mbl3o7a 1 yioLz-6H87xNYmeptVBd_naYaFoNXC6ezSN1200yr3rzTS 10 1-0-0 4-10-0 9&4) 10-8-0 1-0-0 4-10.0 4-10-0 1-0-0 4x8 = e axe = e I.Sx4 II I.5x4 II Scale a 1.24 e 4.10-0 4-10-0 0 4.104) t LOADING (psf) SPACING- 2-0-0 CSI. OEFL. In loc) I/defi L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.41 Vert(LL) -001 6-7 >999 240 MT20 2441190 TCOL 10.0 Lumber DOL 1.25 BC 0.18 Vert(CT) -0.02 6-7 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.08 Horz(CT) 0.00 6 n/a n/a SCOL 100 Code FBC2017f rP12014 Matrix-R Wlnd(LL) 0.00 7 >999 360 Weight: 60 lb FT - 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Structural wood sheathing directly applied or 10.0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. ( lb/size) 8=444/0-3-8.6-444/0-3-8 Max Horz 8=-88(LC 8) Max Uplift 8=-208(LC 10), 6=-208(LC 11) FORCES. ( lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown TOP CHORD 2-3=-379/293, 3-4=3791293, 2-8=-395/360, 4-6=-395/360 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind, ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4 2psf; BCDL=3.Opsf; h-15ft; Cat. II; Exp B; Part Encl. GCpi= 0.55; MWFRS (envelope) gable end zone and C-C Extenor(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.25 plate grip DOL-1.25 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 8= 208.6=208. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jukue Lee PE No.14669 WTek USA, Inc. FL Cert 6611 6104 Parke East Blvd. Tampa FL 33010 Date: April 6,2018 Q wARmmo • vedly design parameters and READ NOTES ON r10S AND INCLUDED UTEK REFERENCE PAGE MO.7473rev. 10101,2015 BEFORE USE. Design valid for use only with Mn ekA connectors. This design Is based only upon parameters shown, and Is rot an Individual building component, not a truss system Before use, the building designer must verify the spit kabi6ty of design parameters and property Incorporate this design Into the overall building design Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only Additional temporary and permanent bracing M iTek' y andtopreventcollapsewithpossiblepersonalInjuryandpropertydamageForgeneralguidanceregardingtheIsalwaysrequiredforatabllamfabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPh1 Quality Cntana, OSS49 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Inatltuta. 218 N Lee Street. Suite 312. Alexandria, VA 22314 Tamps, FL 36610 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 23828-TRAY T13712219IPSQ2382AC2KINGPOST31 b Reference (optionall, Mid -Florida Lumber, Bartow, FL 8.130 s Mar 112018 MiTek Industries, Inc Fn Apr 6 11:47:58 2018 Page 1 10:70b5f8LijaXlSy2mbBo7aly3oLz-aUIN9jZOP67MpmKBLI3po7wlyV CBg9CFghObHzTS17 4-0-0 4.10-0 9.84) 10-8-0 r 1004-10-0 ( 4.10-0 1-o 4x6 = 8 4x8 = 6 1. Sx4 If I Sx4 II Stale = 124.8 1 4.10-0 4.10-0 LOADING ( psQ SPACING- 2-0-0 CSI. DEFL. in loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1 25 TC 0.41 Vert(LL) -0 01 6-7 >999 240 MT20 2441190 TCDL 10.0 Lumber DOL 125 BC 018 Vert(CT) -0.02 6-7 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.08 Horz(CT) 0.00 6 n/a n/a BCDL 100 Code FBC2017/rP12014 Matrix-R Wind(LL) 0.00 7 >999 360 Weight: 55 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No 3 BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. ( lb/size) 8=444/0.3-8.6=444103.8 Max Horz 8=-88(LC 8) Max Uplift 8=-208(LC 10), 6=-208(LC 11) FORCES. ( lb) - Max Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=379/293, 3-4=379/293. 2-8=-395/360, 4-6=395/360 NOTES- ( 6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft, Cat. II; Exp B; Part. Encl., GCpi= O 55, MWFRS (envelope) gable end zone and C-C Exterior(2) zone, end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1 25 plate grip DOL=1.25 3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20 Opsf on the bottom chord in all areas where a rectangle 3-6-0 tell by 2.0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except pt=lb) 8= 208,6=208. 6) Truss is designed with, and confirms to the 2007 Florida Building Code w/2009 supplements. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. U869 MiTek USA, Inc. FL Cart 6634 69N4 Parke East Blvd. Tampa FL 33610 Data: April 6,2018 AWARNING - Ver/ry design penmaws and READ NOTES ON THIS AND INCLUDED MIT EN REFERENCE PAGE NIP7472 m. 1&V2/2015 BEFORE USE. Design valid for use only with MITek® connectors This design is based only upon parameters shown. and Is for an Individual building component, not a truss system Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building deslgn Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only Additional temporary and permanent bracing M iTe k' batwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalInjuryandpropertydamageForgeneralguidanceregardingthefabrication, storage, delivery. erection and bracing of trusses and truss systems, "a ANSI/rPlt Quality Criteria, OS02e and SCSI Building Component 6904 Parke East Blvd. Safety Information sval4ble from Truss Plate Institute, 218 N Lee Street. Suite 312. Alexandria, VA 22314. Tampa, FL 36810 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382E-TRAY T13712220IPS02382ACJ1JACKB1 roil Reference Lionel Mid -Florida Lumber, Banow, FL. 8.130 s Mar 11 2018 MTek Industries, Inc Fn Apr 6 11:47:59 2018 Page 1 ID:V6io2pWMiYja72S7PO2pOly3nnc-2gFIM3a 1 AO7DOwvNv7a2KDTx 1 vM8vASLTKRy7kzTS 1_ 1.0.0 1." 1-0-0 1.0-0 2x4 = LOADING (ps, SPACING- 2-0-0 CST. DEFL. in loc) Udeft L/d TCLL 20.0 Plate Grip DOL 125 TC 0.07 Vert(L-) 0.00 7 999 240 TCDL 10.0 Lumber DOL 125 BC 0.01 Vert(CT) 0.00 7 999 180 BCLL 0.0 ' Rep Stress Incr YES W8 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017frPI2014 Matrix -MP Wind(LL) 0.00 5 999 360 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=10/Mechanical, 2=130/0-7-8, 4=-0/Mechanical Max Horz 2=41(LC 10) Max Uplift 3=-7(LC 10), 2=58(1_C 10) Max Grev 3-1O(LC 17). 2=130(LC 1). 4=12(LC 3) FORCES. (lb) -Max. Comp /Max. Ten. -All forces 250 (lb) or less except when shown. Scale 2 110 PLATES GRIP MT20 244/190 Weight: 5 lb FT = Oeh BRACING - TOP CHORD Structural wood sheathing directly applied or 1.0-0 oc punins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL-3.Opsf; h=25ft; Cat. II; Exp B; Encl.. GCpi=O 18; MWFRS (envelope) gable and zone and C-C Extenor(2) zone;C-C for members and forces S MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonooncurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Judas Lee PE No. UU9 MITek USA, Inc. FL Cert 66U 690/ Perlis East Blvd. Tampa FL 39610 Date: April 6,2018 WARNING - Vedly design parameters and READ NOTES ON TMS AND INCLUDED ANTEN REFERENCE PAGE AM7473 rev. 14102/2015 BEFORE USE. Design valid for use only with MlTalt® connectors. This design is based only upon parameters shown, and Is for an Individual building component, nit a truss system Before use, the building designer must verily the applicability of design parameters and property incorporate this design Into the overall building design Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTe k' Is always (squired or stabeny and to prevent collapse with possible personal Injury and property damage For general guidance regarding the rabrIcatlon. storage, delivery, erection and bracing of trusses and truss systems, see ANSVrPII Quality Criteria. 038419 and SCSI Building Component 6904 Parke East ONO. Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314 Tampa, FL 36610 Job Truss Truss Type Oty Ply erk Scif PEMBROKE 23828-TRAY T13712221LobPS02382ACJ3JACK81 Reference (oolionall Mid-Flodda Lumber, Barlow. FL. 8.130 s Mar 11 2018 MTek Industries, Inc. Fri Apr 6 11:47:59 2018 Page 1 ID:zIFAF9X TrrRg1Bz522xyy3nnb-2gFIM3a1A07DOwvNv9a2KOTxgvLAYASLTKRy7kzTS1_ 1-0-0 3-0-0 1-0-0 3-0-0 Scale. 1"=1, 2x4 = LOADING (psQ SPACING- 24-0 CSC. DEFL. in loc) Udefl Ud TCLL 20.0 Plate Grip OOL 1.25 TC 0.09 Vert(LL) 0 00 4-7 999 240 TCDL 10.0 Lumber DOL 1.25 BC 007 Vert(CT) 001 4-7 999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MP Wjnd(LL) 0.00 4-7 999 360 LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 REACTIONS. ( lb/size) 3=71/Mechanical, 2=188/0.7.8, 4=36/Mechanical Max Horz 2285(LC 10) Max Uplift 3=52(LC 10), 2=64(LC 10). 4=4(LC 10) Max Grav 3-71(LC 1). 2-188(LC 1), 4=52(LC 3) FORCES. ( lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. PLATES GRIP MT20 244/190 Weight 11 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc puriins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd-108mph; TCOL=4.2psf, BCDL=3.Opsf; h=25ft; Cat. II, Exp 8; Encl.. GCpi= 0 18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces d MWFRS for reactions shown; Lumber DOL=1 60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2, 4. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Les PE No. U869 Wall USA, Inc. Fl. Cert 6634 6904 Parka Ead Blvd. Tampa FL 33610 Date: April 6,2018 AWARNING - Verify design parameters end READ NOTES ON THIS AND INCLUDED aaTEN REFERENCE PAGE 110111-7473 rev. 10,1212015 BEFORE USE. Design valid for use only with Mrrek® connectors This design Is based only upon parameters shown, and Is for an Indtmual building component. not a buss system Before use. the building designer must verify the applicability of design parameters and property Incorpotate this design Into the overall buitding design Bractng Indicated Is to prevent buckling of Individual truss web and/or chord members Dory. Additional temporary and permanent bracing k' MOWIsatwaysrequiredforstabilityandtopreventCollapsewithpossiblepersonalInjuryandproperlydamage. For general guidance regarding the fabrication, storage, delivery. IR ry. erection and bracing of trusses and truss systems, sea ANSPII Quality Criteria, 08049 and SCSI Building Component 6904 Parke East Blvd Safety Information available (ram Truss Plate Instltule. 218 N. Lee Street, Suite 312. Alexandria. VA 22314. Tamps, FL 36610 Job Truss Truss Type Park Sq/ PEMBROKE 2382E-TRAYOty JPty T13712222 PS02382A CJ5 JACK 8 1 b Reference Mid -Florida Lumber, Bartow, FL. 8 130 s Mar 112018 MTek Industries, Inc. Fri Apr 6 11:48:00 2018 Page 1 ID•zIFAF9X TrrRI1IBz5Z2xyy9nnb-Wsp8aPbfxkF423UZSj5HIO92pJem0iUi AVfAzTSOz 1 40 5-0-0 1-0-0 5-0-0 Scale - 1.17.0 2x4 = i 5.0.0 5.0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) Udeft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1 25 TC 0.32 Vert(LL) -0 03 4-7 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1 25 8C 0.24 Vert(CT) -0 O6 4-7 >989 180 SCLL 00 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCOL 10.0 Code FBC2017/TPI2014 Matrix -MP Wind(LL) 0.04 4-7 >999 360 Weight 18 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5.0.0 oc purlins. BOT CHORD 2x4 SP No 2 BOT CHORD Structural wood sheathing directly applied or 10.0-0 oc bracing. REACTIONS. (lb/size) 3=128/Mechanical, 2=264/0-7-8, 4=64/Mechanical Max Horz 2=130(LC 10) Max Uplift 3=94(LC 10). 2=80(11-C 10), 4=6(LC 10) Max Grav 3-128(LC 1), 2=264(LC 1), 4-91(LC 3) FORCES. (lb) - Max Comp /Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind, ASCE 7-10: Vuk=140mph (3-second gust) Vesd=108mph; TCDL=4 2psf; BCDL=3.0psf; h=25ft, Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces 3 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tell by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2, 4. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lae PE No.11669 IMTek USA, Inc. FL Cart 68U 6904 Parke Eat Blvd. Tampa FL $3610 Date. April 6,2018 AWARNING • Verily design parameters and READ NOTES ON TWS AND INCLUDED MITEK REFERENCE PAGE MIl•747.1 rev. 10NL2015 BEFORE USE. Design valid for use only with MITak® connaclors. This design Is based only upon parameters shown, and Is tot an Individual building component, not a truss system Before use, the building designer must verity the applicability of design parameters and property Incorporate this design Into the overall bubdng design Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only Additional temporary, and permanent bracing M iTe k' Is always required for stability she to prevent collapse with possible personal injury and property damage For general guidance regarding the fabrication, stotaga, delivery, efaCIW and bracing of trusses and truss systems, sea ANSIrrPI1 Quality Criteria, OS1349 and SCSI Building Component 6904 Parka East Bind Safety Information available from Truss Plata Institute. 218 N. Lea street. Suite 312. Alexandria. VA 22314 Tampa. FL 36610 Job Truss Truss Type City Ply Park Sq/ PEMBROKE 23820-TRAY T13712223 PS02382A D1 HIP 1 1 job Reference (optionall Mid -Florida Lumber, Bartow, FL. 8 130 s Mar 112018 MiTek ID:RUpYTVXcE9zHNIbOXp4HTAy3nna_3N Wntl 1 0-0 3 9 4 7-0-0 11.4-0 15.8.0 20-0-0 1-0-0 3-9.4 3.2.12 4A-0 4.4.0 44-0 54 MT20HS = 54 MT20HS = 3x4 = 3x4 = 54 MT20HS = 4x8 = 3xS = Inc. Fri Apr 6 11.48:01 2018 3-94 Scale - 1.47.2 4x8 = b 0 LOADING (psf) TCLL 20.0 TCOL 10.0 BCLL 00 ' BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017/TPI2014 CST. TC 0.66 BC 094 WB 0.69 Matrix -MR DEFL. in (loc) Udell L/d Vert(LL) -0 24 12 >999 240 Vert(CT) -048 11-12 >678 180 Horz( CT) 0.16 9 n/a n/a Wind( ILL) 0.28 12 >999 360 PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 134 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No 2 TOP CHORD Structural wood sheathing directly applied or 2-3-9 oc purtins. BOT CHORD 2x4 SP No.1 BOT CHORD Structural wood sheathing directly applied or 44-10 oc bracing. WEBS 2x4 SP No.3 REACTIONS. ( lb/size) 2=2302/03-8, 9=230210.3.8 Max Horz 2=78(LC 12) Max Uplift 2--868(LC 8), 9=-868(LC 9) Max Grav 2-2357(LC 18), 9=2357(LC 17) FORCES. ( lb) - Max. Comp /Max. Ten - All forces 250 (lb) or less except when shown TOP CHORD 2-3=-4659/1841, 3.4=-4542/1848, 4-5=-4082/1695, 5-6=4994/2080, 6.7=-4082/1695, 7- 8=4542/ 1848. 8-9=-4659/ 1841 BOT CHORD 2-13=1632/4213, 12-13=2052/5020, 11-12=-2033/5001, 9-11=-1587/4155 WEBS 4-13=-268/1092,5.13=-1158/603,6-11=-11581603.7-11--268/1092 NOTES- 1) Unbalanced roof live loads have been considered for this design 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd-108mph; TCDL=4.2psf; BCDL=3.Opsf, h=25ft; Cat. 11; Exp B; Encl., GCpi= 0.18; MWFRS (envelope) gable end zone, Lumber DOL=1.60 plate grip DOL-1 60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 240.0 wide w ll fit between the bottom chord and any other members. This Item has been 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at -lb) 2= 668, 9=868. electronically signed and 8) Girder carries hip end with 7-0-0 end setback. Sealed by Lee, Julius, PE 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 590 lb down and 306 Ib up at using a Digital Signature. 20- 0-0, and 590 Ib down and 306 lb up at 7-" on top chord. The design/selection of such connection device(s) is the Printed copies of this responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). document are not considered signed and sealed and the LOAD CASE(S) Standard signature must be verified 1) Dead +• Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 on any electronic copies. Uniform Loads (plf) Julius Lee PE No.11669 Vert: 1-4-60, 4-7--131(F--71), 7-t 0=-60, 14-17=-44(F=-24) MiTek USA, Inc. FL Cart 6834 Concentrated Loads (lb) Vert 4=-385(F) 7=-385(F) 8904 Parke East Blvd. Tampa FL 33610 Data: April 6,2018 Q wARN/NG - Verify design poramoters and READ NOTES ON THIS AND INCLUDED NUTEK REFEREN E PAGE AfM7473 rev. 149312015 BEFORE USE. Design valid for use only with MiTek® connectors This design Is based only upon parameters shown, and Is for an individual building component, not a truss system Before use, the building designer must verify the applicability Of design parameters and property Incorporate this design into the overall D: ding design Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Adddronal temporary and permanent bracing MiTek" IskvaysrequlredforstabilityandtopreventcollapsewithpossiblepersonalInjuryandpropertydamageForgeneralguidanceregardingthefabrication, storage, delivery, erection and bracing of (fusses and truss systems, see ANSVrPI7 Quality Crtlerrls, OSS49 and SCSI Building Component 6904 Parka East Blvd. Safely Information available from Truss Plate Instltule, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36810 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 23828-TRAY T13712224IPS02382A02HIP11 b Reference (optional) Mid -Florida Lumber, Banow. FL. 1-"' 4-94 5x5 = 8.130 s Mar 112018 MTek Industries, Inc Fri ID:RUpYTVXeE9zHNtbOXp4HTAy3nna-SFxu 4cvTLVnHNeyai 4.8.0 4-8.0 4-2-12 1 5x4 II 5x5 = 6 11:48:02 2018 4-94 Seine = 1:47.2 3x4 = 3x4 = Sx8 = 3x4 = 3x4 = 7-04 136-0 19-11-12 27-0-0 t 7-04 6-5.12 6-5-12 7-04 1 LOADING (psf) SPACING- 2.0-0 CST. DEFL. in loc) I/dee L/d TCLL 20.0 Plate Grip DOL 1.25 TC 030 Vert(LL) 0.09 11 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.64 Ven(CT) 018 10-11 999 180 BCLL 00 Rep Stress Incr NO WB 0.15 Horz(CT) 0.07 8 file n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MR Wlnd(LL) 0.07 11 999 360 LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. ( Ib/size) 2=1140/0.3-8, 8=1140/0.3.8 Max Horz 2=-97(LC 11) Max Uplift 2=-317(LC 10), 8-317(LC 11) PLATES GRIP MT20 244/190 Weight: 135 lb FT = gab BRACING - TOP CHORD Structural wood sheathing directly applied or 3-10-14 oc purlins 80T CHORD Structural wood sheathing directly applied or 7-3-6 oc tracing. FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown TOP CHORD 2-3-2004/857, 3-4=-1822/804, 4-5=-1626l771, 5-6=-1626/771, 8-7=1822/804, 7- 8=2004/856 BOT CHORD 2-12=-658/1761, 11-12-450/1433, 10-11-450/1433, 8-10=-658/1761 WEBS 3-12-265/221, 4-12=-130/391, 4-11-134/372, 5-11=-278/173, 6-11= 1351372. 6. 10-130/391, 7-10-265/221 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: VuR=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=25tt; Cat. II; Exp 8; Encl.. GCpi= 0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces 6 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except ()t=lb) 2= 317, 8-317. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 34669 Well USA, Inc. FL Cert 6634 904 Perks East Blvd. Tampa FL $3610 Date: April 6,2018 QWARNING - Va lly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIP7473 ew. 10/037015 BEFORE USE. Design valid (or use only with MTek® connectors. This design Is based anti upon parameters shown, and Is for an Individual building component. not a truss system. Before use, the building designer must venly, me theapplicabilityofdesignparametersand property InCorperala this design Into the overall building design Bracing Indicated Is to prevent buckling of individual truss web and/or chord members anti. Additional temporary and permanent bracing M iTe k' Isalwaysrequired (or stability and to prevent Collapse wan possible personal Injury and property damage For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, sea ANSITPI1 Quality Criteria, OSS42 and SCSI Building Component 6904 Parka East Blvd. Safely Information available from Truss Plate Insiduta, 216 N. Lee Street. Suite 312, Alexandda, VA 22314. Tampa, FL 38810 Job Truss Truss Type Oty Ply PEMBROKE 2382E-TRAY IpartSq/ T13712225 PS02382A D3 HIP 1 1 ob Re e e tionel Mia-l-lonaa Lumber, Isanow, I-L. 5.9.4 o.r.wamar I LV to MIVCK I D: RUpYT VXcE9zHNtbOXp4HTAy3nna-wR VGC 18-0-0 21-2.12 o 5.2.12 4x8 =. 04 = 088rf_V3d28 Wafs 11xOyP9FVzTSOw 27 0 0 28-0-0, 5-9 4 1- Scale - 1:47 2 73 1L IV O 30 = ' 1.5x4 11 3x4 = 3x4 3x8 = t.5x4 I) 30 = LOAOING (psO TCLL 20.0 TCDL 10.0 BCLL 00 BCOL 100 SPACING- 2-0-0 Plate Grip DOL 1.25 LumberOOL 1.25 Rep Stress Incr NO Code FBC2017frP12014 CSI. TIC 0.38 SC 0.60 WB 0.37 Matrix -MR DEFL. in (loc) Well L/d Vert(LL) -008 10-12 >999 240 Vert( CT) -0.16 10A2 >999 180 Horz( CT) 0.07 7 n/a n/a Wind( LL) 0.07 12 >999 360 PLATES GRIP MT20 244/190 Weight: 139 lb FT a 0% LUMBER- BRACING - TOP CHORD 2x4 SP No 2 TOP CHORD Structural wood sheathing directly applied or 3-9-13 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 7-3-12 oc bracing. WEBS 2x4 SP No.3 REACTIONS. ( lb/size) 2=1140/0-3-8, 7=1140/0.3-8 Max Horz 2=117(LC 11) Max Uplift 2=-338(LC 10), 7=-338(LC 11) FORCES. ( lb) - Max. Comp /Max. Ten - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1999/846, 3-4=A508f/00, 4-5=-1292/681, 5-6=-1509/700, 6.7=1999/846 BOT CHORD 2-13=-635/1733, 12-13=635/1733, 10-12=-369/1292, 9-10=635/1733, 7-9=635/1733 WEBS 4-12=-115/384, 5-10=-115/384. 3.12=-513/307, 6.102-512/307 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind ASCE 7-10: Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL-3.Opsf; h=25ft, Cat. II; Exp B; Encl.. GCpi= 0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber OOL=1.60 plate grip DOL-1 60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live bad nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2= 338, 7=338. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius lee PE No. 34869 MITak USA, Ina. Fl. Cart 68k 8904 Parka East Blvd. Temps Fl. 33610 0atc April 6,2018 AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED 69TEX REFERENCE PACE M11.7473 rev. 1M03401e BEFORE USE. Design valid for use only wdh MITak® connectors. This design Is based only upon parameters shown, and Is lot an 4MMdual budding component, not a truss system Before Use, the building designer must verify the applicability of design parameters and property Incorporate Ihla design Into the overall building design 8rsdng Indicated Is to buckling of Individual trues web and/or Chord members only. Additional tamporery and permanent bracing M iTek' preventIs always required rot subllily, and t0 prevent collapse with possible personal kQury and property damage For general guidance regarding the febrkatlon, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, OS849 and SCSI Building Component 6904 Parka East BM Safely Infotnrstlon available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314. Tampa, FL 38810 Job Truss Truss Type 0ty Ply Park Sq/ PEMBROKE 23828-TRAY I T13712228 PS02382A D4 HIP 1 1 ReferenceJobdoa Mid-Flodda Lumber, Bartow, FL. S.130 s Mar 11 2018 MTek Industries, Inc. Fri Apr 6 11:48:04 2018 Page 1 ID.RUpYTVXeE9zHNtbOXp4HTAy3nna-Pd3ePme99ylVXhoKhYAD1GAhavMbPV4dcejoxzTSOv r1-0 0, 6-9-4 13-0-0 14-0-0, 20-2.12 27-" 28-0-0 it-00 6-94 8.2.12 1-00 6-2-12 6-9-4 1-0-0 4x8 = 4x8 = 1s 1d - .- V 3x4 = 1 5x4 II 3x4 = 1.5x4 II 3x4 = 3x4 = 30 = LOADING (psf) SPACING- 2-0-0 CSI. OEFL. in floc) VdeO Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.55 Vert(LL) 0.08 13-16 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.69 Vert(CT) 0.18 13-16 999 ISO BCLL 0.0 ' Rep Stress Incr NO WB 0.65 Horz(CT) 0.07 7 n/a n/a BCDL 100 Code FSC2017/TPI2014 Matrix -MR Wind(LL) 0.09 13-16 999 360 LUMBER- BRACING - TOP CHORD 2x4 SP No 2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1140/03-8, 7-1140/0-3-8 Max Horz 2=136(LC 10) Max Uplift 2=-355(LC 10). 7=355(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1954/841, 3-4=1351/659. 4-5=-1135/655, 5-6=-1351/659, 6-7=19541841 BOT CHORD 2-13=-619/1684, 12-13=-619/1684, 10-12=-293/1135, 9-10=619/1684, 7-9=-619/1684 WEBS 3-13=0/284, 6-9=0/284, 4-12=1521376. 5-10=-152/376. 3-12=-657/373, 6.10=-657/373 Scale - 1 53 0 2 orb d PLATES GRIP MT20 244/190 Weight: 137 lb FT = 0% Structural wood sheathing directly applied or 3.7-11 oc puffins. Structural wood sheathing directly applied or 7-3-8 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph, TCDL=4 2psf; BCDL=3.Opsf; h=25tt; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tell by 2-0-0 wide will rd between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at jolnt(s) except (jt=lb) 2=355, 7=355. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. U869 WTek USA, Inc. FL Cert 0834 6204 Parke Eat Blvd. Temps FL $3610 Date: April 6,2018 QWARNIND - Vrffy doslgn parameters and READ NOTES ON THIS AND INCLUDED AUTEK REFERENCE PAGE MII.1473 rev,. 10A11401e BEFORE USE. Oeslgn valid for use only with MfTek* connectors This design Is based only upon parameters shown, and is for an Individual building component, not a truss system Before use, me building designer must verify my of appirstilbtdesignparameters and property Incorporate this design Into the overall bulkeng design Bracing Indicated Is to prevent buckling or Individual truss web and/or chord members only AdddWal temporary and permanent bracing M iTe k' Is alwaysrequiredforstabilityariatopreventcollapsewonpossiblepersonalInjuryandpropertydamageForgeneralguidanceregardingthefabrication, storage, delivery, erection and bracing of trusses and truss systems, sea ANSVTPI1 Quality CMaM, 03049 and SCSI Building Component 6904 Parke East Slid. Safety Information available from Truss Plata Institute, 218 N. Lee Street. Suite 312. Alexandria, VA 22314 Tamps, FL 36610 Job Truss Truss Type oty Ply Perk Sq/ PEMBROKE 2382E-TRAY T13712227 PS02382A E1 HIP 1 1 Job Reference(Optional) Mid-Flodda Lumber, Barlow, FL. 5xS MT20HS = nM f- 13 8.130 s Mar 11 2018 MiTek Industries, Inc Fri Apr 6 11:48:05 2018 ID RUpYTVXcE9zHNIbOXp4HTAy3nna-tgdld6enmGIM I1-t-0 15.5.0 19-9-0 22.114 4-4-0 4.4-0 4.4-0 3.2.12 30 = 30 = 4x4 = 4 5 a 1-0-0' Scale = 145 6 44 = ._ 12 .. 10 3PA = 3x8 = 5x5 = 3x6 = 6.9-0 13-3.0 19-9-0 2&9-0 6-9-0 6.8-0 68-0 7.0-0 Plate Offsets (X Y)- 13:0-3-0 0-2-01 111.0-2.8 0-3-41 LOADING (pso SPACING- 1-0-0 CST. DEFL. in (loc) Udell Ud PLATES GRIP TCLL 20.0 Plate Grip OOL 1.25 TC 0.51 V@n(LL) -0.17 11 >999 240 MT20 244/190 TCOL 10.0 Lumber DOL 1.25 BC 0.73 Vert(CT) -0.35 10-11 >915 180 MT20HS 1871143 BCLL 0.0 Rep Stress Incr NO WB 0.54 Horz(CT) 0.12 8 n/a n/a SCOL 10.0 Code FSC2017/TPI2014 Matrix-R Wind(LL) 0.22 11 >999 360 Weight: 132 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-8-12 oc purlins. BOT CHORD 2x4 SP No.1 BOT CHORD Structural wood sheathing directly applied or 4-10-2 oc bracing WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1705/Mechanical, 8=1708/0-3-8 Max Horz 1-55(LC 13) Max Uplift 1--725(LC 5), 8=715(1.0 9) Max Grav 1=1930(LC 18). 8-1909(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3661/1480, 2-3=3690/1516. 3.4=-3311/1389, 4-5=4084/1707, 5-6=337311403. 6-7=374211537. 7.8=-3729/ 1500 BOTCHORD 1-12=1301/3220, 11-12=-1691/4055, 10-11=-1696/4086.8-10=-1294/3285 WEBS 3-12=-187/769, 4-12=-939/462, 5-10=-911/465, 6.10=-189/773 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph, TCDL-4.2psf; BCDL=3.Opsf; h=25ft; Cat. It: Exp B; Encl.. GCpi=0.18; MWFRS (envelope) gable end zone; Lumber DOL-1.60 plate gnp 001-=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nontoncurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0-0 wide will M between the bottom chord and any other members. This Item has been 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) electronically signed and 1=725, 8=715. sealed by Lee, Julius, PE 9) Girder carries hip end with 7-0-0 right side setback, 6-6-0 left side setback, and 7-0-0 end setback. using a Digital Signature. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 590 lb down and 306 lb up at Printed copies of this 20-0.0. and 548 lb down and 284 lb up at 6-" on top chord. The design/selection of such connection device(s) is the document are not consideredresponsibilityofothers 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Signed and Sealed and the signature must be verified LOAD CASE(S) Standard 1) Dead F Roof Live (balanced): Lumber Increase=l 25, Plate Increase=1.25 Julius L99 PE No. 34669 Uniform Loads (plf) MiTek USA, Inc. FL Cart 6634 Vert: 1-13=-30, 3.13=101(F=-71), 3-6=-101(F=-71), 6-9=-30, 1-8-34(F=-24) 6904 Parka East Blvd. Tempe FL Mill094ConcentratedLoads (lb) Van 6=-385(F) 13=-358(F) April 6,2018 Q WARNING. Verily design parameters and READ NOTES ON "a$ AND INCLUDED MITEK REFERENCE PAGE 1111II.7173 rev. IWa3/201S BEFORE USE. Design valid to use only with MfTek® connectors. This design Is based only upon parameters shown, and Is for an IndAMMusl building component, not a 'Piss system. Before use. the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall o:ding design. Bracing Indicated Is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek' Is tways required for stability and to prevent collapse with possible personal Injury and property damage For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPI11 Quality Criteria, OSS49 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N Lee Street, Suite 312. Alexandria, VA 22314 Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq/ PEMBROKE 23828-TRAY T13712228IPS02382AE2HIP11 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. S.130 s Mar 11 2018 MTek Industries, Inc. Fri Apr 6 11:48:06 2018 Page 1 10:RUpYTVXcE9zHNtbOXp4HTAy3nna-LOAPgSfOXa70m71gpzCh6hF4 kbn3RzN4wdgsgzTSOt 4-04 8.9-0 13-3-0 17-9-0 , 21-11-12 26.9-0 27-9.0 4-6 4 4.2.12 441-0 48-0 4-2.12 4-94 1-0-0 5x5 = 1.Sx4 II 5x5 = Scale = 1.45 7 axe = 3x4 = 10 3x4 = 3x4 = 5x8 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. In (loc) uden L/d PLATES GRIP TCLL 20.0 Plate Grip OOL 1.25 TC 0.34 Vert(LL) -0.08 10 >999 240 MT20 244/190 TCOL 10.0 Lumber DOL 1.25 BC 0.65 Vert(CT) -0.17 9-10 >999 180 BCLL 0.0 Rep Stress Incr NO WB 014 Horz(CT) 0.07 7 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix-R Wlnd(LL) 0.07 10 >999 360 Weight: 132 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-10-11 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 7-5.11 oc bracing WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1058/Mechanical, 7=1129/0-38 Max Horz 1=-106(LC 11) Max Uplift 1--278(LC 10). 7=-317(LC 11) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=1890/812. 2-3=-1724/771, 3-4-1567/749, 4-5=-1567/749, 5.6-1756/776, 6-7=1950/823 BOT CHORD 1-11=-612/1619. 10-11=-428/1369, 9-10=431/1384, 7-9--625/1677 WEBS 3-11=-114/344, 3- 10- 134/374, 4-10=273/172, 5.10=-131/355. 5-9=118/373 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCOL=4.2psf; BCOL=3.Opsf; h=25ft; Cat. 11; Exp 8; Encl.. GCpi=0.18: MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces S MWFRS for reactions shown: Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10 0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0-0 wide will fit between the bottom chord and any other members 6) Refer to girder(s) for truss to truss connections This item has been7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) 1-278, 7=317. electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 34969 MITsk USA, Ina. FL Cart 6634 6904 Parke East Blvd. Tamps FL 33810 Date: April 6,2018 AwARNINO. Verify design parameters and READ NOTES ON TNIS AND INCLUDED AUTEK REFERENCE PAQE AW-7473 rev. 10N341015 BEFORE USE. Design valid for use only with WT*k* connectors. This design Is based only upon parameters shown, and Is for an individual building Component. not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall budding design Bracing Indicated is to prevent buckl4p of Individual Was web and/or atom members only Additional temporary and permanent bracing M iTe k' Is always required for stability and to prevent Collapse with possible personal Injury and property damage. For general guldsnce regarding the fabrication, storage, delivery, erection and bracing of tmssas and truss systems, Bee ANSVTPII Quality Ci teria, OS82e and SCSI Building Component 6804 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexendds, VA 22314 Tamps, FL 36610 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 23828-TRAY T13712229IPS02382AE3HIP11 Job Reference toptional) Mid -Florida Lumber, Bartow, FL. 3 5.0-0 4x8 = 8.130 s Mar 112018 MiTek Industries. Inc. Fit Apr 6 11:48:07 2018 I D:000_IrPrX6A 17ixkOkOl H4y3oLu-pCkn2og21t7408 WvNhjwtvoCxSxConWJaNN01 4x8 = 5-2-12 30 = 12 11 -- 9 8 3x4 1 5x4 II 3x4 = 3x4 — 3xS = 1 5x4 II 1-0-0 Scale = 1.46.5 5.9.4 it-" i to-0-0 21.2.12 2744 5.9.4 5.2-12 5-0-0 5-2-12 5.94 Plate Offsets (X Y)- 11:0-2-0 Edael 13 0.5-4 0-2-0I 16:0.2-0 Edoel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.52 Vert(LL) -0 O8 11 >999 240 MT20 244/190 TCOL 10.0 Lumber DOL 1.25 BC 0.64 Vert(CT) -0.16 9-11 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.36 Horz(CT) 007 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix-R Wnd(LL) 0.07 11 >999 360 Weight: 137 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-8-7 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 7.2.1 oc bracing. WEBS 2x4 SP No 3 REACTIONS. (lb/size) 1-1068/Mechanical, 6=1139/0-3.8 Max Horz 1=-125(LC 15) Max Uplift 1=-304(LC 10), 6=-339(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 1-2=-19831840, 2-3=1484/693. 3.4=-1269/673, 4-5=-14831690, 5-6=19671823 BOT CHORD 1-12=-632/1698, 11-12=-632/1698,9-11=-363/1270,8-9=-614/1682,6-8=-614/1682 WEBS 2-11=-500/310, 3-11=-115/375, 4-9=111/373, 5.9=482/290 NOTES- 1) Unbalanced roof live loads have been considered for this design 2) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCOL=4.2psf; BCDL=3.Opsf; h-25ft; Cat. 11; Exp B; Encl.. GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces d MWFRS for reactions shown; Lumber DOL=1.25 plate grip DOL-1.25 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10 0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide Will rd between the bottom chord and any other members 6) Refer to girder(s) for truss to truss connections 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) This item has been1-304, 6=339. electronically signed and sealed by Lee, Julius, PE using a Digital Signature Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lae PE No. 34869 MITek USA, Inc. FL Cert 6834 6904 Parka East Blvd. Tampa FL 33810 Date: April 6,2018 QWARNING - Verily design paameters and READ NOTES ON THIS AND INCLUDED M1TEK REFERENCE PAGE MI47472 rev. 1010312015 BEFORE USE. Design valid for use only, with MITek® Connectors This design Is based only upon parameters shown, and is for an Individual building Component, not a truss system. Before use, the building designer must verity, the appllcabllly of design parametem and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent budding of Individual truss web and/or Chord members onty. Additional temporary and permanent bracing M iTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, ue ANSVTPII Quality Criteria, 031369 and SCSI Building Component 6904 Pena East Blvd. Safety Information available from Trust Plata Institute. 216 N. Lee Street, Suite 312. AlexandM, VA 22314 Tamps, FL 36610 Job Truss Truss Type 0ty Ply Park Sq/ PEMBROKE 2382E-TRAY I T13712230 PS02382A E4 HIP 1 1 Job Reference (optional) Mid-Flonda Lumber, Bartow, FL. 0d d 6 130 s Mar 11 2018 MiTek Industries. Inc Fill Apr 6 1148 06 Zola 6-2-12 '1-0-0' 6-2-12 6-9.4 44 = 44 = 12 11 9 a 3x4 = 1.5x4 II 3x4 = 1 5x4 II 3x4 = 3x4 = 3x4 = LOADING (par) SPACING- 2-0-0 CSI. DEFL. in floc) Udefl Ud TCLL 20.0 Plate Grip DOL 1.25 TIC 0.55 Vert(LL) 0.08 8-18 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.68 Vert(CT) 0 17 8-18 999 180 BCLL 0.0 Rep Stress Incr NO WB 0.65 Horz(CT) 007 6 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MR Wind(LL) 0.09 8-18 999 360 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEBS 2x4 SP No 3 REACTIONS. (lb/size) 1=1069/Mechanical, 6=1131/03-8 Max Horz 1=-I49(LC11) Max Uplift 1=-320(LC 10), 6=354(LC 11) FORCES. (lb) -Max. Comp /Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1884/820, 2-3=-1331/653, 3-4=1119/650, 4-5=-1333/654, 5-6=1934/835 BOT CHORD 1-12=-597/1613, 11-12=597/1613, 9-11=-288/1119, 8-9=-613/1666, 6-8=613/1666 WEBS 2-12=0/260, 5.8=0/283, 3-11=146/363, 4-9=-151/373, 2-11=-602/354, 5.9-655/373 Scale a V52.4 PLATES GRIP MT20 244/190 Weight: 135 lb FT - 0% Structural wood sheathing directly applied or 3.7-14 oc purlins. Structural wood sheathing directly applied or 7-3-15 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCOL=4.2paf; BCOL-3.0psf; h-25ft; Cat II; Exp B; Encl , GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces 6 MWFRS for reactions shown; Lumber DOL-1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live bed nonconcuffent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6.0 tell by 2-0.0 wide will rd between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=320,6=354. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lse PE No. UU9 MiTek USA, Inc. FL Cart 6634 62U Parks East Blvd. Tampa FL 33610 Date: April 6,2018 QWARNING • verify design penmefers and READ NOTES ON THIS AND INCLUDED aarEN REFERENCE PAGE a111.7473 rev. 10 0312015 BEFORE USE. Design valid for use only with MRek* connectors. This design Is based only upon parameters shown, and la for an Individual budding component, not a truss system Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overact building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and pennanam bracing MiTek• is always required for stability and to prevent collapse with possible patsonel Injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrtP11 Quality Collette, 05849 and SCSI Building Component 6904 Parke East Blvd Safely Informallon available from Truss Plate Inshtute, 218 N. Lee Street, Suite 312. Mexandds. VA 22314. Tampa, FL 38810 Job Truss Truss Type City Ply Park SW PEMBROKE 2382E-TRAY I T13712231 PS02382A F1 FLOOR 3 1 D Referenceoral Mid -Florida Lumber, Bartow, FL 0.1-8 H 1III 4x5 = lx3 = lx3 = 4x4 1 2 t321 u. iju s mar n zui o mi i ex mausmes, inc, rn rtpr o n n:9o:vv Lu 1st raga i ID JG33Jta6HOTIrUvgmf9DdOy3nnW-IbsXSUilgVNodSgIU6mOkKISHxYSGddpnusUT9zTSOq 1.64 Scale = 1:48.8 34 = 3x4 = 3x4 = 34 = 34 = 3x3 = 3x8 FP = 30 = 3x4 = 4x4 = 4xa 3 4 5 6 7 a 9 10 11 12 13 30 29 26 27 26 2524 23 22 21 20 19 18 17 16 15 14 1.5x4 II 4x8 = 04 = 3x5 = 3xa MT20HS FP = 18 11 24 II 2.6 II 34 11 10 11 3x5 = 4x4 = 4x8 = 3x3 II 3x4 = 3x3 = 3x9 11 3x3 = 3x4 = 17 27.34 27-3-4 Plate Offsets (X Y)- f 1 •Edae 0-1-81 f21.0-3-0 0.0.01 122 0-3-0 Edael LOADING (psf) SPACING- 1-7-3 CSI. OEFL. in (loc) I/deb L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 091 Vert(LL) 0.71 21-22 >453 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 SC 093 Vert(CT) 0 98 21-22 >330 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.79 Horz(CT) 0.12 14 n/a n/a BCOL 5.0 Code FBC2017/TPI2014 Matrix-R Weight 158 lb FT = 0%F, 0%E LUMBER- BRACING - TOP CHORD 2x4 SP No. ID(flat) *Except' TOP CHORD Structural wood sheathing directly applied or 2-2-0 oo purlins, 9-13. 2x4 SP No. 1(flat) except end verticals. BOT CHORD 2x4 SP No. ID(flat) *Except* BOT CHORD Rigid ceiling directly applied or 10.0-0oc bracing. Except: 18- 26: 2x4 SP No 2(flat) 2-2-0 oc bracing: 25-27,17-19. WEBS 2x4 SP No.3(flat) REACTIONS. ( lb/size) 30=118510-7-8, 14=118510.3.8 FORCES. (lb) - Max Comp /Max. Ten - All forces 250 (lb) or less except when shown. TOP CHORD 1-30=1179/0, 13- 14=1178/0, 1-2=1190/0, 2-3--3192/0, 3-4=4701/0, 4-5=6056/0, 6713/0, 6-7--6922/0, 7- 8--6724/0, 8-10=-6075/0, 10-11=-4733/0, 11-12=-3236/0, 12-13=-1243/0 BOT CHORD 28- 29=0/2309, 27- 28=0/4045, 25-27-0/5468, 23-25=0/6499, 22-23=0/6922, 21-22=0/6922, 20-21=0/6922, 19.20=0/ 6514, 17-19=0/5494, 16.17=0/4083, 15-16=0/2360 WEBS 1-29=0/1617, 2-29= 1558/0, 2-28=0/1227, 3-28=-1187/0, 3-27=0/912, 4-27=-1065/0, 4-25=0/799, 5-25=-600/ 0, 5-23=0/454, 6-23 =6531222, 6-22=285/317, 13-15=0/1655, 12-15=1553/0, 12-16=0/ 1218, 11-16=-1177/0, 11-17=0/904, 10-17=1057/0, 10-19=0/790, 8-19=-595/ 0, 8-20=0/450, 7-20=-644/233, 7-21=-291/312 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Required 2x6 strongbacks, on edge, spaced at 10.0.0 oc and fastened to each truss with 3-110d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. This Item lies been 4) CAUTION, Do not erect truss backwards. electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julies Lee PE No. 31666 MiTek USA, Inc. FL Cart 6634 6204 Parka Ent Blvd. Tampa FL 32410 Date: April 6,2018 AWARNINO - Verity design parameters end READ NOTES ON TMS AND INCLUDED WTEK REFERENCE PA E 111I1.7473 rev. I8934016 BEFORE USE. Design valid for use, only with MrrekB connectors This design Is based only upon parameters shown, and is for an Individual building component, no a truss system. Safam use, the bulldog designer must verity the applicability of design parameters and property Incorporate this design Into the overall building design Bracing Indicated Is to prevent buckling of Individual trans web and/or aldd members only. Additional temporary and permanent bracing M iTek' Is always required for stability and topreventcollapsewithpossiblepersonalInjuryandpropertydamage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, see ANSVIPII Quality Crites. OSB49 and SCSI Building component 6904 Pit" East Blvd Safety Information available from Truss Plate Institute. 216 N Lee Street. Suite 312. Mexandria, VA 22314. Tampa. FL 36610 Job Truss Truss Type Oty Perk Sq/ PEMBROKE 2382B-TRAY JPly T13712232 PS02382A F2 FLOOR 4 1 D rnail Mid -Florida Lumber. Barlow. FL. 0-t-0 H 1F3-0 3x4 = 2 a.130 s Mar 11 2018 MI1 ex Industnes, Inc, 1-n Apr 6 11:46:13 2016 Page 1 ID:onWk7XR53jO1ol56V9OmMVy3oLs-eM62ldptjuD63 3ptgKvA2DTYymCTPPhVghcwzTSOm 1t—t4 Scale = 1:32.4 34 = 34 = 1x3 II 1x3 II 34 = 3x3 = 3x4 = 4x8 = 3 4 5 6 7 8 9 10 1.50 II 4x8 = 3x4 = 3Y3 = 3x3 = 34 = 3x3 = 3x4 = 4x8 = 3.3 II 19.4.4 Plate Offsets (X.Y)- f 1:Edne.0.1-81 LOADING (psf) SPACING- 2-0-0 CSI. OEFL. In (loc) Vdefl L/d PLATES GRIP TCLL 400 Plate Grip DOL 1.00 TC 0.58 Vert(LL) -031 15-16 >742 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 SC 0.76 Vert(CT) -0 42 15-16 >540 240 SCLL 0.0 Rep Stress Incr YES WB 0.67 Horz(CT) 0.07 11 n/a n/a BCDL 50 Code FBC2017/TPI2014 Matrix-R Weight. 101 lb FT - O%F, 096E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flet) TOP CHORD Structural wood sheathing directly applied or 5-8-9 oc purlins, BOT CHORD 2x4 SP No.l(flat) except end venicals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. REACTIONS. ( ID/size) 20-1047/0.7-8,.11=1047/Mechanical FORCES. ( lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-20=-1041/0, 10-11-1041/0, 1-2=1018/0, 2-3=-2621/0, 3.4=-3621/0, 4-5=4102/0, 5- 6=4102/0, 6-7-4102/0. 7-8=3640/0, 8-9=2654/0. 9-10-1063/0 BOT CHORD 18-19=0/1967, 17-18=0/3249, 16-17=0/3968, 15.16=0/4102, 14-15=0/3978, 13-14=0/3274, 12- 13=0/2008 WEBS 10.12=0/1415, 1-19=0/1384, 9-12=1315/0, 2-19=-1320/0, 9-13=0/898, 2-18=0/910, 8- 13=-862/0, 3-18=-873/0, 8-14=0/509, 3.17=0/518, 7-14=-471/0, 4-17=-481/0, 7- 15=-184/485.4-16=-174/495 NOTES- ( 5) 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-110d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. 5) Truss is designed with, and confirms to the 2007 Florida Building Code w/2009 supplements 17 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 34869 I iTek USA, Inc. FL Ceft 8834 6904 Parke Ent Blvd. Tamps FL 13610 Date: April 6,2018 WARNING - Verify design parameters and READ NOTES ON 710S AND INCLUDED MITEx REFERENCE PAGE 11111.7472 rev. 1"112013 BEFORE USE. wwww Design valid for use only with MITek® connectors This design Is based only upon parameters shown, and Is for an indtmual building component, not El atrusssystem. Before use, the building designer must verify the applkabaity of design parameters and property Incorporate this design Into the overact busting design. SWIng Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTe k' IsalwaysrequiredforstabadyandtopreventcollapsewithpossiblepersonalInjuryandpropertydamage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, see ANSVIPI1 Quality Cnteds. OS1349 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N Lee Shoat. Suite 312, Alexandria, VA 22314. Tamps, FL 36610 Job Truss Truss Type City Ply Park Sq/ PEMBROKE 2382E-TRAY T13712233 PS02382A F3 FLOOR 5 1 Job Reference (optional) Mid-Flonda Lumber, Barlow, FL. 6 13u s mar n zu1 n mi f ex Industries, me Fri Apr b i i:46: i4 40td rage f 10: oSdR WDb12hbaTeULKMgSADy3nnV-6Z(OWBIRe l O4jDZFH(LZRNaPdyiNxmYw9ZF8MzTS01 0. 1.8 Hi 1-3-0 state• are•=1• 4x4 1x3 = 1x3 = 3x4 = 3x3 = 3x3 = 1x3 11 1x3 II 3x3 = 3x3 = 3x4 = 4x6 = 1 2 3 4 5 6 7 6 9 10 2 1 1. 50 II 4x6 = 3x4 = 3x3 = 34 = 3x3 = 34 = 3x4 = 4x6 = 3x3 II I 18. 11.12 1& 11.12 Plate Offsets (X Y)- I1 •Edge 0-1-81 LOADING ( psf) SPACING- 2-0-0 CSI. OEFL. in loc) Udell Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 100 TC 0.56 Vert(LL) 0 29 15 786 360 MT20 2441190 TCOL 10.0 Lumber DOL 1.00 BC 0.73 Vert(CT) 0.39 15 572 240 BCLL 00 Rep Stress Incr YES WB 0.66 Horz(CT) 0.07 11 n/a n/a BCDL 5.0 Code FBC2017/rP12014 Matrix-R LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD BOT CHORD 2x4 SP No.l(flat) WEBS 2x4 SP No.3(flat) BOT CHORD REACTIONS. ( lb/size) 20=1027/0-7-8, 11=1027/Mechanical FORCES. ( Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-20=-1020/0, 10-11=1020/0, 1-2=996/0, 2-3=2556/0, 3-4=-3514/0, 4-5=-3947/0, 5- 6=3947/0, 6-7=-3947/0, 7-8=-3532/0, 8-9-2588/0, 9-10=1040/0 BOT CHORD 18-19=0/1924, 17-18=0/3163, 16-17-0/3840, 15.16=0/3947, 14-15=0/3850, 13-14=0/J187, 12- 13=0/1964 WEBS 10-12=0/1384, 1-19=0/1353, 9-12-1285/0, 2-19=-1291/0, 9-13=0/868, 2-18=0/880, 8- 13=-832/0, 3-18=-844/0, 8.14=0/480, 3-17=0/489, 7-14=-442/0, 4-17=-452/0, 7- 1 5=- 193/423, 4-16=- 184/432 Weight, 100 lb FT - 0%F, O%E Structural wood sheathing directly applied or 5-10-12 oc puffins, except end verticals. Rigid ceiling directly applied or 10.0.0 oc bracing NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10.0-0 oc and fastened to each truss with 3-1Od (0 131" X X) nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 34869 fdiTek USA, Inc. FL Cert 8634 004 Parke East Blvd. Temps FL 33610 Date: April 6,2018 O WARNING • Verify design parameters and READ NOTES ON rrOS AND INCLUDED MITEx REFERENCE PAGE Mn•7473 rev. 1410=016 BEFORE USE. Design valid for use only with MRek* contractors This design Is based only upon parameters shown, and is for an Individual building Component• not a ( fuss system. Before use. me building designer must ver0y the applicability of design parameters are property Incorporate this design Into Iha overall buading design Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members ony, Addalonal temporary and permanent bracing WOW Isalways (squired for stability and to prevent Collapse with posslde personal Injury and property damage For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. tea ANSVTPI/ (justify Criteria, OS849 and BCSI Building Component 6904 Parke Fast Blvd Safety Information available from Truss Plate Insdtule. 218 N. Lae Street, Suite 312. Ale andda, VA 22314 Tampa. FL 36610 Job Truss Truss Type Oty Ply Perk Scil PEMBROKE 2382E-TRAY T13712234 PS02382A F4 FLOOR 3 1 e u all Mid-Flodda Lumber, Bartow, FL. t-0 4x6 = 3x5 = 1 2 8 130 s Mar 11 2018 MiTek Industries, Inc Fri Apr 6 11:48:15 2018 Page 1 I D:oSdR W Dbl2hbaTeULKMgSADy3nnV-alDojXm3PL8xLN7SrMto_b7UdMargM9i9pJohozTSOk 1f =12 I ah8 Scale - 1 34 4 4x4 = 1x3 = 3x3 = 18 FP = 10 = 14 II 3x3 = 3x3 = 34 = 3x5 = ba = 3 4 5 8 7 a 9 10 11 3X3 11 4x5 = 3x5 = 34 = 34 = Ix3 II 3x3 = 310 = 3xS MT20HS FP = 4x5 = 1.5x4 II 1.Sx4 SP = 3x5 = LOADING (psf) SPACING- 2.0.0 CSI. DEFL. In (loc) Udefl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.86 Vert(LL) 0.39 17-18 628 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.00 BC 0.97 Vert(CT) 0.53 17-18 457 240 MT20HS 187/143 BCLL 00 Rep Stress Incr YES WB 0.72 Horz(CT) 0.08 12 n/a nla BCDL 50 Code FBC2017/TPI2014 Matrix-R LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD BOT CHORD 2x4 SP No. 10(flat)'Except' 12-15: 2x4 SP No.2(flat) BOT CHORD WEBS 2x4 SP No 3(flat) 'Except' 1.23,11-12: 2x4 SP No 2(flat) REACTIONS. (lb/size) 23= 11 14/Mechanical, 12=I I14/0.7-8 FORCES. (lb) -Max. Comp /Max. Ten. -All forces 250 (lb) or less except when shown TOP CHORD 1-23=1106/0, 11-12=-1107/0, 1-2=1137/0, 2-3=-2868/0, 3-5=-3981/0, 5-6=4634/0, 6.7=4634/0, 7-8=-4546/0, 8-9=3972/0, 9-10--2829/0, 10-11--1090/0 BOT CHORD 21-22=0/2152, 20-21=0/3553, 19-20=0/4402, 18-19=0/4634, 17-18=0/4634, 16-17=0/4403, 14-16=0/3521, 13-14-0/2 109 WEBS 11-13=0/1482, 1-22=0/1514, 10.13=1417/0, 2-22=1412/0, 10-14=0/1002, 2-21=0/996, 9-14=-962/0, 3-21=-952/0, 9-16=0/628, 3-20=0/596, 8-16--599/0, 5-20=-585/0, 8-17=-43/378, 5.19=113/603, 7-17=431/218 25 p 24 ¢^ Weight: 107 lb FT = O%F, OOAE Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: IS- 19.17-18,14-16. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Refer to girder(s) for truss to truss connections. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0.0 oc and fastened to each truss with 3.10d (0.131" X 3") nails. Strongbacks to be attached to wells at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. UN9 Welt USA, Inc. FL Cart 86U 8981 Parke East Blvd. Tampa FL 33818 Oats: April 6,2018 QWARN/NG - Vrffy design pammerrs and READ NOTES ON TNIS AND INCLUDED MITEK REFERENCE PAGE Ma-7473 rev. 1003/2015 BEFORE USE. wwwe Design valid for use any with MITek® connectors This design Is based only upon parameters shown, and Is for an Individual buUding component• not matrusssystem. Before use, e building designer must verity me applicability design parameters and properly Incorporate this design into the overall building design. 8nctng Indicated Is ro prevent buckling of Individual truss web and/or chard members only Additional temporary and permanent bracing M iTe k' Is always required for stabUdy and to prevent collapse with possible personal Injury and property damage For general guidance regarding the fabrication• storage, delivery, erection and bracing of trusses and truss systems, sea ANSVrPI1 Quality Criteria. DS849 and SCSI Building Component 6904 Parke Fast Blvd Safety Information available from Truss Plate Institute, 218 N Lee Street. Suite 31Z Alexandria, VA 22314 Tampa, FL 36610 Job Truss Truss Type City Ply Perk Sq/ PEMBROKE 2382E-TRAY T13712235 PS02382A F5 FLOOR 1 1 b eee i al Mid-Flonda Lumber, Banow, FL. 1-3-0 0.10.12 I 06 = 04 = 3x10 = 34 1 2 3 4 a 13U s Mar 11 ZUIa MI lel( mausmes, Inc, rn Apr o 1 r90 to xv to rage i 10:oSdRWDb12hbaTeULKMgSADy3nnV-2xnBxtnhAeGozXieO4OlWogfOm TPo4rOT2LDFzTSOi 1.4.0—i 0-ke Scale = 126.8 3x3 = 3x3 II 30 = 5 6 7 4x4 = tx3 = 3x4 = 1x3 = e 9 IIS o oa a L1 a,I lll,oe •e'. sue_ taai.IYaaaaaaaaaY--ar 34 II 4x6 = 4x10 = 34 = 3x3 = Ix3 II 3,61 = 3x4 = 44 = 1 5x4 II t 3-f0-0 9-t0A 10-74 fi , 17.2.12 3-10-0 OA 12 743 Plate Offsets (X Y)- f 1 •Edna 0.1-81 13.0.4-8 Edael f9 0-1-8 Ednel f 17:0-4-8 Edael LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udell L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.86 Ven(LL) -0 25 14-15 >797 360 MT20 244/190 TCOL 10.0 Lumber COL 1.00 BC 0.76 Vert(CT) -0.35 14-15 >582 240 SCLL 0.0 Rep Stress Ina NO WB 0.81 Horz(CT) 005 10 rile n/a SCOL so Code FBC2017/TPI2014 Matrix-R LUMBER- BRACING - TOP CHORD 2x4 SP No.1(88t) TOP CHORD SOT CHORD 2x4 SP DSS(Oat) WEBS 2x4 SP No.3(8at) BOT CHORD REACTIONS. (lb/size) 19=123610-3-0.10=1015/0-7-8 FORCES. (lb) - Max Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-19=-1228/0, 9-10=-1014/0, 1-2=1272/0, 2-3=-3149/0, 3-4=-3540/0, 4-5=-3836/0, 5-6=3666/0, 6-7=-3666/0, 7-8=-2490/0, 8-9=992/0 BOT CHORD 17-18=0/2409, 16.17-0/3181, 15-16=0/3858, 14-15=0/3666, 13-14=0/3666, 12-13=0/3110, 11-12=0/1899 WEBS 3-17=-447/0, 1-18=0/1694, 2-18=1581/0, 2-17=0/1133. 9-11=0/1349, 3-16=0/475, 8-11=-1261/0, 4-16=443/0, 8-12=01822, 7-12=-861/0, 5-15=-234/459, 7-13=0/911, 6.13=-334/0, 5-14=-321/37 21 20 Weight 96 lb FT = 0%F, O%E Structural wood sheathing directly applied or 5-4-6 oc punins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10.0-0 oc and fastened to each thus with 3.10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Co not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00. Plate Increase=1.00 Uniform Loads (pit) Vert 10-19=10, 1-9-100 Concentrated Loads (lb) Vert: 17-390 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lot PE No. 34669 1UTek USA, Inc. FL Cart 6634 6904 Parka East Blvd. Temps FL 32610 Date: April 6,2018 QWARNING - verity design parameters and READ NOTES ON rids AND INCLUDED AGTEK REFERENCE PAGE 1111114473 rev 14602/2016 BEFORE USE. Design valid for use only with M(Tek® Connectors. This design Is !used only upon parameters shown, and Is for an Individual buiding component, not a truss system. Baton use, the building designer must verily the appibabibty, of design parameters and properly Incorporate this design Into the overall building design Bracing Indicated Is to prevent buckling of individual truss web and/or Chord members only. Additional temporary and permanent bracing M iTek' Is always required for stability and to prevent Collapse with possible personal Injury and property damage For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss Systems, sea ANSIrTPI/ Quality Criteria, DS829 and SCSI Building Component 6904 Parke East Blvd. S4foy Information available hom Truss Plata Institute, 218 N Lee Street, Suite 312. Alexandria. VA 22314. Tamps, FL 38610 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382E-TRAY T13712236 PS02382A F6 FLOOR 1 1 o all Mid -Florida Lumber, Banow. FL. a.130 s Mar 11 201a Mtfex Industries, Inc. I-n Apr 5 11:413:10 tote Page 1 ID:M9eWDSMDLgT1LEVd2SERwy3oLq-2xnBxtnhAeGozXieO4O1WogmKm cPuprOT2LDFzTSOj 113 11 —4-12 I--I- Scale - 122 2 3x4 = 1x3 = 34 = 3x3 = 14 II 34 = 34 = 1x3 1 3xe — 2 3 4 5 6 7 ur1 V4 I • Ir_e i .r. .ra som rA Y Y Y-i Y Y Y- 3x3 II 3x4 = 3rf3 = tx3 II 34 = 3x3 = LOADING (psf) SPACING- 2-0.0 CSI. DEFL. in (loc) Vdefl Ud TCLL 40.0 Plate Grip OOL 100 TC 0.41 Ven(LL) 0.10 10-11 999 360 TCDL 10.0 Lumber OOL 1.00 BC 075 Vert(CT) 0.14 10-11 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.44 Horz(CT) 0.03 8 n/a n/a SCOL 5.0 Code FBC2017/TPI2014 Matrix-R LUMBER- BRACING - 3x4 = 1x3 II PLATES GRIP MT20 244/190 Weight 71 lb FT - O%F, O%E TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc punins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. REACTIONS. (lb/size) 15-720/0-3-8, 8=720/0.7-8 FORCES. (lb) -Max. Comp /Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-15=715/0, 7-8--713/0, 1-2=-693/0, 2-3-1602/0, 3_4=-1918/0, 4-5=1918/0. 5-6--1591/0, 6-7-664/0 BOT CHORD 13-14=0/1299, 12-13=0/1918. 11-12=0/1918, 10-11=0/1865, 9-10=0/1279 WEBS 7-9=0/902, 1-14=0/923, 6-9=-856/0, 2-14=-842/0, 6-10=0/434, 2-13=0/431, 5-10=-381/0, 3-13=504/0, 5-11=-122/308 NOTES- (4) 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0 131" X Y') nails. Strongbacks to be attached to walls at their outer ends or restrained by other means 3) CAUTION, Do not erect truss backwards. 4) Truss Is designed with, and confirms to the 2007 Florida Building Code w/2009 supplements. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. U%9 MiTek USA, Inc. FL Cert 81131 6904 Parks East Blvd. Tampa FL 33610 Date: April 6,2018 AWARWNG - VaAfy design parameters and READ NOTES ON INS AND INCLUDED MIIEK REFERENCE PAGE MI147473 rev. 1"312015 BEFORE USE. Oesign valid for use only with MlTalt® connector$ This design Is based only upon pararmtere shown, and Is for an Individual building component, not truss system Before use. the budding designer must verity the applicablury of design parameters and property Incorporate this design Into the overall eulkeng design Bracing Indluted Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTe k' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, OSB42 and SCSI Building Component e904 Parks East BIM Safety Information available hornTruss Plate Institute. 21e N. Lee Slraet, Suite 312. Mexandds, VA 22314. Tamps, FL 36610 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382&TRAY 1 T13712237 PS02382A F7 FLOOR 3 1 Job Reference clfo Mid -Florida Lumber, Bartow, FL. 1f.0 ti.lju s mar n zulo mueK mausmes. Inc rn Ppr o t l:go:to zuto rage i ID:M9eVYDSMbLgT1LEVdZSERwy3oLq_ KvxLZpxiGWWCrs1WV0VbD15HZ(NtoD8mXSH7ZTSOh 0" Scale - 1. 22.4 3x4 = lx3 3x3 = 3x3 = 1x3 II 3x3 = 3x3 = 1x3 = 1 3x8 2 3 4 5 6 7 z7Kz:&z - 15 14 13 12 11 10 9 3x3 II 3x4 = 3x3 = tx3 II 3x3 = 3x3 = 3x4 = 1.311 13.64 r 13- 6- 4 Plate Offsets ( X Y)— 17.0.1-8 Edaei LOADING (pso SPACING- 2.0-0 CSI. DEFL. In (loc) I/deft Ud PLATES GRIP TCLL 40. 0 Plate Grip DOL 1.00 TC 0.45 Vert(LL) -0.11 10-11 >999 360 MT20 244/190 TCDL 10. 0 Lumber DOL 1.00 BC 079 Vert(CT) -0.15 10-11 >999 240 BCLL 0. 0 Rep Stress Incr YES WB 0.44 Horz(CT) 0.03 8 n/a n/a BCDL 5. 0 Code FBC2017frP12014 Matrix-R Weight: 71 lb FT = 0%F, 0%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, BOT CHORD 2x4 SP No.2(flat) except end verticals WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing REACTIONS. (lb/ size) 15=726/Mechanical, 8=726/0-7-8 FORCES. (lb) - Max. Comp /Max Ten. - All forces 250 (lb) or less except when shown TOP CHORD 1-15=722/0, 7-8=-720/0, 1-2=701/0, 2-3=1624/0, 3-4=-1953/0, 4-5=-1953/0, 5.6=-1613/0, 6-7=-671/0 BOT CHORD 13-14=0/1313, 12-13=0/1953, 11-12=0/1953, 10.11=0/1893, 9-10=0/1294 WEBS 7- 9=0/912. 1-14=0/933. 6-9=-86610. 2-14-851/0, 6-10=01444, 2-13=0/443, 5-10=-389/0, 3-13=523/0, 5-11=- 117/323 NOTES- (5) 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10.0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards 5) Truss is designed with, and confirms to the 2007 Florida Building Code w/2009 supplements. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 34669 MiTek USA, Inc. FL Cert 6634 6104 Parke East Blvd. Tampa FL 33610 Date: April 6, 2018 AWARNING • Verily design parameters and READ NOTES ON TNIS AND INCLUDED earrEK REFERENCE PAGE M/F7473 rev. 1060MOfS 6EFORE USE Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a trues system. Galore use, the building designer moat verify the applicability 01 design parameters and property Incorporate this design Into the overallOu"ding designBracingIndicatedIstopreventbucklingofIndivWttaltrussweband/or chord members only. Additional temporary and permanent bracing M iTe k' Ia always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, OSS49 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 21a N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa. FL 36610 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382E-TRAY T13712238IPS02382AF8FLOOR31 Job Reference (optional) Mid -Florida Lumber, BenOw, FL. 5.130 s Mar 11 2010 Mi lek Industries, Inc. I-n Apr d 11:45:19 2010 Page 1 IO:rMBtmZT_MeoKfVphBHzT 8y3oLp-SWTJZupaTZeNq_RD4Cxk8RIHdzlHcfmH4RHOgazTSOg 1I3.0 F 1-0—t Olaf Scale = 1 21 A 1 3x8 = 3x3 = 2 3x3 = Ix1l II 34 = 3 4 5 3x3 = 6 3x4 = tx3 = 71x3 = 34 II 30 = 34 = tx3 II 34 = 34 = 30 = Ix3 II LOADING (psf) SPACING- 2.0-0 CSI. DEFL. in (loc) Udefl Lid PLATES GRIP TCLL 40.0 Plate Grip OOL 100 TC 0.41 Vert(L-) 0.08 10-11 999 360 MT20 2441190 TCOL 100 Lumber OOL 100 SC 0.62 Ven(CT) 011 10-11 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(CT) 0.02 8 We n/a BCOL 5.0 Code FBC2017/TPI2014 Matrix-R Weight: 70 lb FT = O%F, 0%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORO Structural wood sheathing directly applied or 6.0-0 oc punins, SOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing REACTIONS. ( Ib/size) 15=699/0.3.8, 8=699/0.7-8 FORCES. ( lb) - Max. Comp./Max. Ten -All forces 250 (lb) or less except when shown TOP CHORD 1-15=694/0, 7-8=693/0, 1-2=-670/0, 2-3=1535/0, 3-4=-1816/0, 4-5=1816/0, 5.6=-1525/0, 6.7=-642/0 BOT CHORD 13-14=0/1256, 12-13-0/1816, 11-12=0/1816, 10.11-0/1780, 9-10=0/1235 WEBS 7-9=0/873, 1-14=0/893, 6-9=-825/0, 2-14=-815/0, 6-10=0/403, 2-13=0/395, 5-10=-356/0, 3-13=445/0, 5- 11=136/268 NOTES- ( 4) 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3.10d (0.131" X 3") nails Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. 4) Truss Is designed with, and confirms to the 2007 Flonda Building Code w/2009 supplements. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Juhue Lee PE No.11669 WTek USA, Inc. FL Cart 6694 1101 Parka East Blvd. Tampa FL $3610 bate: April 6,2018 Q wARNINO - Verify design parameters and READ NOTES ON TMS AND INCLUDED NITEK REFERENCE PAGE NO.7473 rev. 1"341015 BEFORE USE. Oesign valid for use anti with Mf rak® connectors. This design Is based only upon parameters shown, and Is for an IndtMusl building Component, not a truss system Before use, the building designer must vent' Ina applicability of design parameters and property Incorporate this design Into the overall building design Bracing Indicated Is to prevent buckling of Individual truss web and/or chard members only. Additional temporary and permanent bracing M iTek' IsalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalInjuryandpropertydamageForgeneralguidanceregardingthefabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPII Quality Criteria, OS840 and SCSI Building Component 8304 Parke East BIM Safety Information available from Truss Plate Institute, 218 N Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 38810 Job Truss Truss Type Oly Ply Perk Sq/ PEMBROKE 23828-TRAY Tt3712239IPS02382AF9FLOOR21 Job Reference loptionall Mid -Florida Lumber, Banow, FL 1 1.3.0 It, 1:AI a Mar 11 Lu10 MI I ex industries, inC Fri NPr 0 11 40 zu Lu 10 raga r I D:uz46LtSiq 1 YcOBgJ3sx?vjy3oLr-xi 1 hmEgCEtmES80PdwSzhegRONM6LhORI50ZMOzTSOf 1.04 0-0 Scale = 133 9 34 = lx3 3x3 = lx3 II 3x3 = 3x8 FP= 3x8 = 3x3 = 3x3 = 1x3 II 3x3 = 34 = 1x3 = 2 3 4 5 6 7 8 9 10 11 12 EVENaIn. PA /I&E i 1: OF II fx3 II 3x3 = 3x3 = lx3 II 3x3 = 3x3 II 4x4 = 13 = lx3 II 31A = 34 FP = 3x3 = tx3 II 3x3 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.47 Vert(LL) 0.07 15-17 999 360 MT20 2441190 TCDL 10.0 Lumber DOL 100 BC 0.65 Vert(CT) 0.10 15-17 999 240 SCLL 0.0 Rep Stress Ina YES WB 0.47 Horz(CT) 0.01 13 n/a Na BCDL 5.0 Code FBC2017/TP12014 Matrix-R LUMBER- BRACING - TOP CHORD 2x4 SP No.2(ftat) TOP CHORD BOT CHORD 2" SP No.2(flat) WEBS 2x4 SP No 3(flat) BOT CHORD REACTIONS. (lb/size) 26=238/0.3.8, 13=605/0-7-8, 21=1357/0.7-8 Max Uplift 26=31(LC 4) Max Grav 26=335(LC 3), 13=619(LC 4), 21=1357(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-26=-332/27, 12-13=-611/0, 2-3=-369/329, 3-4=-369/329, 4-6-14/582, 7-8=-950/0, 8-9=1357/0,9-10=-1357/0, 10-11=-1278/0, 11-12=553/0 BOT CHORD 24-25=-1411458. 23-24--329/369, 22-23=329/369. 21-22=-922/0, 20-21=-92210. 19-20=0/ 576, 18-19=0/1357, 17-18=0/1357, 15-17=0/1444, 14.15=0/1066 WEBS 12-14= 0/752, 11-14=-713/0, 11-15=0/295, 10-17--2581103, 6-21=-1321/0, 1-25 68/338, 2-25=-291/ 126, 2-24=-363/0, 6-22=0/620, 4-22-655/0, 6.20=0/978, 7-20=907/0, 7-19=0/ 547.8-19=-586/0 28 q 27 Weight: 108 lb FT 2 O%F, C%E Structural wood sheathing directly applied or 6-0.0 oc purlins, except end venicals Rigid ceiling directly applied or 6-0-0 oc bracing. NOTES- (5) 1) Unbalanced Boor live loads have been considered for this design. 2) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 31 lb uplift at joint 26 3) Recommend 2x6 srongbacks, on edge, spaced at 10.0-0 oc and fastened to each truss with 3.10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means 4) CAUTION, Do not erect truss backwards 5) Truss is designed with, and confirms to the 2007 Florida Building Code w/2009 supplements. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lie PE No. 34868 MITek USA, Inc. FL Cart 6634 490/ Parka East Blvd. Tampa FL 31610 Date: April 6, 2018 O WARNING - Vault' design peramerors and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Ma-1/73 mv. 1M1l1013 BEFORE USE. sesses Design valid for use only with Mrraklb connectors This design Is based only upon parameters spawn, and Is for an Individual building component. not a truss system Before use, Ina building designer must vent' the applicability of design parameters and property Incorporate this design Into me overall bullCing assign. Bntlnp kWlcaled Is to prevent buckling of Individual truss web and/« chord members only. Additional Temporary and permanent bracing M iTe k' I,always requiredforstabilityandtopreventcollapsewithpossiblepersonalInjuryandpropertydamage. For general guidance tagalong the fabrication, storage, delivery, exaction and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, OS849 and SCSI Building Component 8904 Parke East Blvd Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 223 M Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382E-TRAY T13712240IPS02382AF10FLOOR11 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 6.130 s Mar 11 2010 Mi l ek Industries, Inc. Fn Apr 0 11.40:10 2015 Page 1 ID•uz46LISlg1YcOBgJ3sx?viy3oLr-DnOvgpiwboVfFcFU2pHdHXOgRL5k?8fz?Xbl?bzTSOp 1 3.0 1.3.12 0" Scale - 1:17.9 34 = 3x4 II 34 = 34 1x3 = 1 3x6 — 2 3 434 — 5 e,x3 = 34 11 34 = 4x4 = 14 II 34 = 12 16-0 2.6-0 1$-12 1.3.0 26.0 1-46 0-1 Plate Offsets (X Yl— 111 0-1-8.Edgel LOADING (psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 400 Plate Grip DOL 100 TC 0.76 Ven(LL) 000 8 "" 360 MT20 244/190 TCDL 100 Lumber DOL 1.00 BC 007 Vert(CT) -0.00 11-12 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.55 Horz(CT) 0.00 7 n/a n/a BCDL so Code FBC2017/TPI2014 Matrix-R Weight. 58 lb FT = C%F, 096E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(8at) TOP CHORD Structural wood sheathing directly applied or 10.0-0 oc purlins, BOT CHORD 2x4 SP No.2(8at) except end verticals. WEBS 2x4 SP No 3(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing REACTIONS. All bearings 10-8-4 lb) - Max Grav All reactions 250 lb or less at joint(s) 13, 7, 7 except 8=308(LC 1), 9=356(LC 1). 12=315(LC 1), 11=2619(LC 1), 10=319(LC 1) FORCES. (lb) - Max. Comp./Max Ten - All forces 250 (lb) or less except when shown. WEBS 5.8=-342/0, 5-9=-398/0, 2-12=369/0. 2.11--331/0, 3-11=-2384/0, 4-10=-316/0 NOTES- 1) Unbalanced floor live loads have been considered for this design 2) Recommend 2x6 strongbacks, on edge, spaced at 10.0.0 oc and fastened to each truss with 3.10d (0 131" X T') nails Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=l 00, Plate Increase=1.00 Uniform Loads (plf) Vert: 7-13=5, 1-6=-174 Concentrated Loads (lb) Vert,3=-2296 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 34969 MITek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 6,2018 AWARNINO - Verify design parameters and READ NOTES ON Ties AND INCLUDED ANTEK REFERENCE PACE M/l-7473 rev 10M3/2015 BEFORE USE. Design valid for use only with WSW connectors This design Is based only upon parameters shown, and Is for an Individual budding component, not a truss system. Before use, the budding designer must verity, the applicability of design parameters and properly Incorporate this design Into the averse building design Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only Adddlonal temprary and permanent bracing M iTek' Is always required for etabedy and to prevent collapse On possible personal Injury and property damage For general guidance regarding the fabrication, storage, deilvery, erection and bracing of trusses and truss systems, see ANSIrrPl1 Quality Crlterla, OS842 and SCSI Building Component 6904 Parke East Blvd Safety Information available from Truss Plate Institute. 210 N. Lee Street. Suite 312. Mexandds, VA 22314 Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382E-TRAY T13712241 PSO2382A F11 FLOOR 2 1 Job Referenoe o to I Mid -Florida Lumber, Bartow, FL 0.1.8 H F 1 3 —I 3x4 = 2 34 3 a.1su s mar it zu1 c ml t ex mausmes, roc. rn twr o 1 1:9o- 1 1 zu la raua i I0:uz46LtSjq 1 YcOBgJ3sx7,4y3oLr-h_It9jYL6eWsmggcXospMTIGEkZj6EBLbX t zTSOo 1f— 5.0 3x3 = 1x3 II tx3 II 3x3 = 4 5 6 7 Scale - 133 0 3x3 = 3x4 = 44 = 6 9 10 q4 1 5x4 II 4x6 = 30 = 3x3 = 3x3 = 3x3 = 3x3 = 3x4 = 4x6 = 3.3 II LOADING (psf) SPACING- 2-0-0 CSI. OEFL. in loc) Udell Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.61 Vert(LL) -0 33 15-16 >709 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.82 Veft(CT) -0 45 15-16 >516 240 BCLL 00 Rep Stress Incr YES WB 0.69 Horz(CT) 008 11 n/a n/a BCDL so Code FBC2017/TPI2014 Matrix-R Weight. 102 lb FT = 0%F, 0%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 5-6-13 oc purlins, BOT CHORD 2x4 SP No 1(Oat) except end verticals. WEBS 2x4 SP No.3(flat) 'Except' BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. 1-20,10-11: 2x4 SP No 2(flat) REACTIONS. (lb/size) 20=1064/0-7-8, 11=1064/0.7-8 FORCES. (lb) - Max Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-20=-1058/0, 10-11=-1058/0, 1-2=1037/0, 2-3=-2675/0, 3.4=3711/0, 4-5-4233/0. 5-6=4233/0, 6-7=-4233/0, 7-8=-3730/0, 8-9=2709/0, 9-10=-1082/0 BOT CHORD 18-19=0/2003, 17-18=0/3321, 16-17=0/4074, 15-16=0/4233, 14-15=0/4086, 13-14=0/3347, 12-13=0/2046 WEBS 10-12=0/1441, 1-19=0/1409, 9-12=1339/0, 2-19=-1345/0, 9-13=0/923, 2-18=0/935, 8-13=-887/0, 3-18=-898/0, 8-14=0/533, 3-17=0/542, 7-14=495/0, 4-17=-505/0, 7-15=173/539, 4-16=-162/549. 5.16=-254/33 NOTES- (4) 1) Unbalanced floor live loads have been considered for this design 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0 131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means 3) CAUTION, Do not erect truss backwards. 4) Truss is designed with, and confirms to the 2007 Florida Building Code w12009 supplements. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lite PE No. 34669 MITek USA, Inc. FL Cart 06U 6904 Parke East Blvd. Tampa FL 33610 Date: April 6,2018 AWARNING - WAry design parameters and READ NOTES ON rMS AND INCLUDED MITEK REFERENCE PAGE 01.7473 rev. 10A13/2016 BEFORE USE. asseas Oeslgn valid for use only with MITex® connectors This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Sefore use, the building designer must vent' the applicability of design parameters and property Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only Additional temporary and permanent bracing M iTe k' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, OS13-89 and SCSI Building Component 6004 Parke East Blvd Safety Information available from Truss Plate Insbtule, 210 N Lee Street, Suite 312. AlexandM, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sy PEMBROKE 2382E-TRAY T13712242 PS02382A F12 FLOOR 5 1 b Reference Lionel Mid-Flonda Lumber, Bartow, FL 4 a.t,1u s mar n tuto mneR Inausutes, me rn Apr a i i:ao:n zuto rage t ID Clla8EedLrs9K6DW?UD9osy3nnS-h_It9jYL6eWsmggcXosp"SvkjR6EBLbX1zTSOo t 6-0 3x6 = 2 34 II 3x3 II 3 3x6 = Seale = 1.9 5 LOADING (psf) TCLL 400 TCDL 10.0 BCLL 0.0 BCOL 5.0 SPACING- 1.0-0 Plate Grip DOL 1.00 Lumber DOL 1.00 Rep Stress Incr NO Code FBC2017/TPI2014 CSI. TC 047 BC 0.01 WB 0.00 Matrix-P DEFL. in Vert(LL) 0.00 Vert(CT) -000 Horz( CT) 0.00 loc) Well Ud 4 "" 360 4 > 999 240 n/ a n/a PLATES GRIP MT20 244/190 Weight: 15 lb FT - 0%F, 0%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(8at) TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing REACTIONS. ( lb/size) 4=1553/Mechanical, 3=157/Mechanical FORCES. ( lb) - Max. Comp /Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 14=-1549/0 NOTES- 1) Refer to girder(s) for truss to truss connections. 2) Recommend 2x6 strongbacks, on edge, spaced at 10.0.0 oc and fastened to each truss with 3.10d (0 131" X 3") nails Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front F) or back (8). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase-1.00 Uniform Loads (plf) Vert: 3.4=5, 1-2-174(F=124) Concentrated Loads (lb) Vert: 1=1397 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 34369 WTek USA, Inc. FL Cart 0034 904 Parka Eau Blvd. Tampa FL 33610 Date: April 6,2018 AWARNING • Verity design parameters and READ NOTES ON TNS AND INCLUDED MITEK REFERENCE PACE Af&7473 rev. Id03r2015 BEFORE USE. Design valid for use only with MlTak* connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual trust web and/or chord members only. Additional temporary and permanent bractng M iTe k' IsalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalInjuryandpropertydamage. For general guidance regarding the labrkatlon. storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Cdteds, OSS29 and SCSI Building Component 6904 Parke Fast SW Safety Information available from Truss Plate Institute, 218 N Lee Street, Suite 312, Alexandria, VA 22314 Tsmpa, FL 36610 Job Truss Truss Type Oty Ply Perk Sg/ PEMBROKE 2382&TRAY T13712243 PSO2382A F13 FLOOR I 1 Job tional Nuci-I-lonoa Lumber, uanow. I-L. 1-3-0 d. i ju a mar it cw i o rm i eoo muubut—, ,— — two u r .-ro. 4 o r yo 10•uz46LtSigIYcOBgJ3sx7viy3oLr-AAYg5VkA6omNUwP19EJ5MyV 19cgT71FTr484UzTSOn Scale - 1.16 7 6x8 = 6x8 MT18HS = 2.6 II 2xe II 6x8 MTISHS = 6xS = 1 2 3 4 5 13 6 34 II 04-0 0 4-0 8.6-12 8.6-12 Plate Offsets (X Y)- 13:0.3-0 Ednel 14 0-3-00-0-01 16 0-3-O Edoel 19.0-3-0 Edael 110:0-3-0 Edoel LOADING ( psi) SPACING- 1-0-0 CSI. DEFL. in (loc) Udefl Ltd PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 088 Vert(LL) 0.04 10-11 999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0 80 Vert(CT) 0.06 10-11 999 240 MT18HS 244/190 8CLL 0.0 Rep Stress Incr NO WB 0 73 Horz(CT) 0.01 7 n/a n/a BCDL 5.0 Code FBC2017/TPI2014 Matra-P Weight: 72 lb FT - WAIF. 048E LUMBER- BRACING - TOP CHORD 2x4 SP No 1(flat) TOP CHORD BOT CHORD 2x4 SP No.2(ftat) WEBS 2x4 SP No.2(flat) 'Except' BOT CHORD 1- 12,6.7,3-10,4-9: 2x4 SP No 3(flat) REACTIONS. ( lb/size) 12=2413/0.7-8, 7=-391/1-7-4, 8=4190/1-7-4 Max Uplift 7=-391(LC 1) FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-12=-2405/0, 6.7=6/358, 1-2=-2028/0, 2-3=-3164/0, 3.4--3164/0, 4-5=-3164/0, 0/ 1461 BOT CHORD 10.11=0/3816, 9.10=0/3164, 8-9=0/1974 WEBS 1-11=0/2582, 6.8=1860/0, 2-11-2369/0, 5-8=4545/0, 2-10=-1203/232, 5-9=0/1608, 3. 10=-147/334, 4-9=718/0 Structural wood sheathing directly applied or 6-0-0 oo puffins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 391 Ili uplift at joint 7. 4) Recommend 2x6 strongbacks, on edge, spaced at 10d10 oc and fastened to each truss with 3-1Od (0.131" X Y) nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert 7-12--5, 1-6=-742 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No.34669 IdiTek USA, Inc. FL Cart 6634 6904 Parke Ent Blvd. Tampa FL 31610 Date: April 6,2018 AWARNING - Verify design parameters and READ NOTES ON rMS AND INCLUDED h9TEK REFERENCE PAGE 61/147473 rev. 10103/2015 BEFORE USE. Design valid far use only with Mrrakel conneclora This design Is based only upon parameters $town, and Is for an Individual building component. not truss system. Before use, the building designer must verify the applicability of design parameters and property mcorporate this design Into the overall budding design. Bracing Indicated Is to prevent buckling of Individual truss web andfa chord members onty. Additional temporary and permanent bracing WOWI$ alwaysrequiredforstablldyandtopreventcollapsewithpossiblepersonalInjuryandprspertydamage. For general guidance regarding the fabrication. storage, delivery, erecllon and bracing of trusses and truss systems, ass ANSUTPH Quality Criteria, OSS49 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, Vil N. Lee Street. Suds 312. Alexendria, VA 22314. Tampa, FL 36610 Job Truss Truss Type 0ty Ply Park Sq/ PEMBROKE 2382B•TRAY T13712244 PS02382A G1 HIP 1 b Reference (oolionall Mid -Florida Lumber, Bartow, FL. 3.9.3 13.0.3 ID 6x8 MT18MS = 1 5x4 II 7x8 = 4x10 = c. It 4 S 6 7 8.13u a Mar 11 Zulu MIJ eK Inaustnes, Inc Fn Apr b 11.41122 2018 1. 11.11 '1.11•t3 ' 3.0.3 3.0.3 34-3 t Sx4 11 4 9 = 6x8 MT18HS = e 10 1_5x4 II 400112 24 23 22 21 20 19 18 17 16 15 14 34 II 4x8 = 8x8 = 34 II 1Ox10 = 34 II axe = 4x8 = 3x6 11 34 II axe II Scale - 167 4 LOADING ( psf) TCLL 20.0 TCDL 10.0 BCLL 0.0 ' BCDL 10.0 SPACING- 1.4-0 Plate Grip DOL 100 Lumber DOL 1.00 Rep Stress Incr NO Code FBC2017/TPI2014 CSI. TC 0.87 SC 0.96 WB 0 96 Matrix- R DEFL. in (loc) Uden L/d Vert( LL) 0.19 20 >999 360 Vert( CT) -0.34 20-21 >935 240 Horz( CT) -0.03 1 n/a n/a PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 877 Ill FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.1 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x8 SP No.2 'Except' BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. 16- 22: 2x8 SP No 1 WEBS 2x4 SP No 3 *Except* 25- 26,27-28,10-17,4-21,9-28,5-26: 2x4 SP No.2 19- 26.19-28: 2x4 SP No.1 REACTIONS. ( lb/size) 13=361/0.7-8, 1-3705/0-7-8, 17=11433/0-5.8 Max Horz 13=54( 1-C 9) Max Uplift 13=-574( LC 18). 1=1354(1-C 4), 17=-4106(LC 5) Max Gram 13=168( LC 4), 1-3801(LC 18). 17=12123(LC 17) FORCES. (lb) - Max. Comp / Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 10.11- 1571/4957, 11-12=-1582/4800. 12-13=-644/2201, 4-5=7633/2646, 5-6=4481/1393, 6-7=4679/1465, 7-8=1186313917. 8-9=12193/4024, 9-10=1643/4955, 1-2=10969/3873. 2-3=9221/3200, 3-4=9204/3264 BOT CHORD 1-24= 3614/10352. 23-24=-3614/10352, 21-23=242en646, 20-21=-2439/7685, 19-20=-2430/7661, 18-19=-3650/1419, 17-18=-3588/1397, 15-17-3860/1487, 14-15=-2053/676, 13-14=-2053/676 WEBS 12-14=165/ 606. 12-15=328311272, 2-23=-2213/892, 2-24=270/135. 20-26=-966/311. 6.26=-1679/565, 7-19=3984/1283, 25.26=- 516/241, 18-28--5269/1766, 8-28-1352/456, 27-28=-2315/7074, 17-27=-6772/2369, 10-27=- 2494/957, 21-25=-145/613, 4-25=-69/517, 10-15=-1221/279, 4-23=-802/1973, 5-25- 239/528, 9-27=9749/3210, 9-28=3159/9565, 5-28=-3176/1174, 7-28--2147/6598, 7-28=- 913/394, 19-26=-3192/1184, This item has been 19-28=-4278/12900 electronically signed and NOTES- sealed byLee, Julius, PE 1) 3-ply truss to be connected together with 10d ( 0.148"4") nails as follows using a Digital Signature. Top chords connected as follows: 2x4 - 1 row at 0- 9-0 oc. Printed copies Of this p Bottom chords connected as follows 2x8 - 2 rows staggeredat0-" oc. Webs connected as follows: 2x4 - 1 row at 0.9- 0 oc. document are not considered 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (8) face in the LOAD CASE(S) section. Ply to signed and sealed and the ply connections have been provided to distribute only loads noted as (F) or (8), unless otherwise indicated signature must be verified 3) Unbalanced roof live loads have been considered for this design. On any electronic copies. 4) Wind: ASCE 7-10: Vull= 140mph (3-second gust) Vasd-108mph; TCDL=4 2psf; BCDL=3.Opsf, hail 5ft, Cat. 11, Exp B; Encl., Julius Lee PE No. Y1869 GCpi=0.18, MWFRS (envelope) gable end zone; Lumber DOL= 1.25 plate grip OOL=1.25 Cott6 MITek USA, Inc. fL Ce834 rt8 5) Provide adequate drainagetopreventwaterponding. 6) AllplatesareMT20platesunlessotherwiseindicated. 890/ Perko East Blvd. P fl k 810 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Gate 8) ' This truss has been designed for a live load of 20 Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide April 6,2018 AWARN/NO - Verity design parameters and READ NOTES ON INS AND INCLUDED 88rEK REFERENCE PA E NIH7473 rev. /0N312015 BEFORE USE. Oesrgn valid got use only with MiTak* connectors This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the appllcabllity, of design parameters and property Incorporate this design Into the overall building design Bracing Indicated Is to prevent budding of Individual truss web and/or chord members only Addi lonal temporary and permanent bracing M iTe k' Is always required for stability and to prevent collapse withpossiblepersonalinjuryandpropertydamageForgeneralguidanceregardingthefabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, OS849 and BCSI Building Component 6904 Parke East Blvd Safety Information available from Truss Plate Institute. 218 N Lee Street, subs 312. Alexandria, VA 22314 Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 23828-TRAY T13712244IPS02382AG1HIP1 Job Reference o do el Mid-Flonda Lumber, Bartow,FL. 8.130 It Mar 11 2018 MiTek Industries, Inc Fri Apr 6 11:46:22 ZU16 rage 2 10:JYIFzvUc7ywBHeOuk UiXLy3oLo-t58SBwsSmUOyhSAoIKVRm3whiB IpT7kmPVgOuzTSOd NOTES- 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 574 lb uplift at joint 13, 1354 lb uplift at joint 1 and 4106 lb uplift at joint 17. 10) Girder carries tie-in span(s): 2.6-0 at 0-0.0 to 7-0-0 at 12-9-12 ; 74).0 at 27-0-12 to 2-6-0 at 39-10-8.; 27-0-0 from 12-9-12 to 27-0-12 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1727 lb down and 657 lb up at 7-0-12. and 1727 lb down and 657 lb up at 32-9-12 on top chord The design/selection of such connection device(s) is the responsibility of others LOAD CASE(S) Standard 1) Dead Roof Live (balanced): Lumber Increase=1.00, Plate Increase-1 00 Uniform Loads (plo Vert: 4-10=-599, 1-13=-13 Concentrated Loads (lb) Vert: 12-1727 2=-1727 Trapezoidal Loads (plf) Vert: 10=1344o-13=46, 1-46-to-4=-134 AWARNINO - Verlry d*afgn psnmafars and READ NOTES ON rids AND INCLUDED WFEK REFERENCE PAGE MIA7472 rev. 10N212016 BEFORE USE. Oesign valid for use only with MITak® oonnactars. This design Is based only upon parameters Shawn, and Is for an IndMduSl building component. not a truss system Before use, the building designer must verify the applircablbly of design parameters and property Incorporate this design Into the overall ouuding design Bracing indicated Is to prevent budding of Individual Me web andfor lard members only Addelanal temporary Snd permanent brardng M iTe k' Is always required for stability and to prevent collapse with possible personal Injury and property damage for general guidance regarding the fabrication, storage, delMry, erection and bracing of trusses and truss systems, sea ANSUTPII Quality Criteria, OS849 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N Lee Street, Suite 312, AlexandM. VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq/ PEMBROKE 2382E-TRAY T13712245 PS02382A G2 FLAT 1 b Reference (ontionall Mid -Florida Lumber, Bartow, FL. 8.130 s Mar 11 2018 MTek Industries, Inc Fri Apr 6 11:48:23 2018 Page 1 ID:nkJdAEVEuF22uoz4liOx32y3oLn-LHigPGs4Xo8pJd_J20glHS1JaLHY tl?3FDzLzTSOc 2 3.11 4-5-10 8-76 8.9.3 10.10.14 13-0.8 15.26 174-5 19.8-0 04 2-3-11 2.1.15 2-1-14 2-1-t1 2-1-11 2-1-10 2.1.14 2.1.15 2-3.11 Scale - 1:34.3 US II 4x10 = 1x4 11 3x4 = 3x8 = 1x4 11 3x12 = US II 3x10 = 13x10 = 2 3 4 5 B 7 21 6 9 10 US 5x12 = 2x4 II dx10 = 6x12 MT20HS = 2x4 11 3x10 = 2x4 II Sxt2 = 5x8 MT20HS II 1 2-3-11 d-5.10 ( n-7A &9.3 10.10.14 1 13-06 15.2$ 174-5 19^a LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) Udell Ud PLATES GRIP TCLL 40.0 Plate Grip OOL 1.00 TC 0.81 Vert(L-) 0.44 15-16 >532 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.87 Ven(CT) 0.73 15-16 >316 240 MT20HS 187/143 BCLL 0.0 Rep Stress Ina NO WB 0.74 Horz(CT) 0.08 20 n/a n/a BCDL 5.0 Code FBC2017frPI2014 Matnx-R Weight: 440 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP DSS TOP CHORD Structural wood sheathing direly applied or 2-9-3 oc purllns, BOT CHORD 2x6 SP DSS except end verticals. WEBS 2x4 SP No.3 'Except' BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. 10-11, 2x4 SP No.2 1-19.3-19.3-17.5-17.8-12,10-12.8-14,E-14,6.16: 2x4 SP No.1 REACTIONS. (lb/size) 11-7804/0-7-8, 20=573610.7-8 Max Uplift 11-2471(LC 4), 20=-1915(LC 4) FORCES. (lb) - Max. Comp./Max. Ten -All forces 250 (lb) or less except when shown. TOP CHORD 10-11=6745/2146, 1-2--11344/3816, 2-3=-11344/3816, 3-4=29808/10213, 4-5=29808/10213, 5-6=31529/10654, 6.7=-29895/9925, 7-8-29895/9925, 8-9=13985/4482. 9-10=13985/4482 BOT CHORD 18-19=7675/22578. 17-18=7675/22578, 16-17=10654/31529, 15.16=-10642/31864. 14-15=-10642131864, 13-14=8340/25571, 12-13-8340/25571. 11-12--576/1828 WEBS 4-17=-3686/1384, 7-14--2100(782, 2-19=488/235. 3-18=288/856. 1-20=5330/1788, 9-12-1633/687, 8-13=217/694, 5-16-3911704. 6.15=-255/887, 1-19=-4174/12409, 3-19=-12288/4221,3-17=2778/7912,5-17=-1915/860,8-12=-12673/4220. 10-12=-4273/13298,8-14=-1917/4732,6.14=2245/1411,6.16=1925/1577 NOTES- 1) 4-ply truss to be connected together with 10d (0.148"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9.0 oc. Attach TC w/ 1/2" diam. bolls (ASTM A-307) in the center of the member w/washers at 4-0-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (8). unless otherwise indicated. 3) Wind: ASCE 7-10; Vult-140mph (3-second gust) Vesd-108mph; TCDL=4.2psf; BCDL=3 Opsf; h=15ft: Cat. II: Exp B, Encl., GCpi=0.18: MWFRS (envelope) gable end zone: Lumber DOL=1.25 plate grip DOL=1.25 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise Indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2471 lb uplift at joint 11 and 1915 lb uplift at joint 20. 9) Girder carries tie-in span(s): 2-8-0 at 0-0-0 to 6-6-0 at 6.9-4.; 27-0-0 from 13-2-12 to 19-8-0 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. UH9 WTak USA, Inc. FL Cart 6634 61104 Parka East Blvd. Tampa FL 33610 Date: April 6,2018 Q wARN/No - Verify design parameters end READ NOTES ON TWS AND INCLUDED SUNK REFERENCE PAGE MII.7473 raw. 10A343015 BEFORE USE. Design valid for use only with MITak® Connectors This design Is based only upon parameters shown, and is for an IndNWual budding Component, not a truss system. Before use, the budding designer must verity the appllabWN of design parameters and property InCorporate this design Into the overall budding design. Bracing Indicated Is to prevent bueWIng of Individual vest web andfor Chord members oroy Additional temporary and permanent lxecbv M iTe k' Is always required for stability end to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, dait"ry, erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, OSS49 and SCSI Building Component 6904 Parke East Blvd Ssfaty Intorma tion available from Truss Ptate Institute, 216 N Lee Street. Suite 312. Alexandria, VA 22314 Tampa, FL 36810 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382&TRAY T13712245IPS02382AG2FLAT1 job Reference (optional) Mid-Flodda Lumber, Barlow. FL. 8 130 s Mar 11 2018 MiTek Industries, Inc. Fri Apr 6 11 48:23 201E Page 2 ID.nkJdAEVEuF22uoz4liOx3ZyJoLn-LHigPGs4Xo8pJd J20glHStJaLHY tt73FDzLzTSOe NOTES- 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3724 lb down and 1390 lb up at 6-7-8. and 1790 lb down and 692 lb up at 13-4-8 on top chord, and 152 lb down at 6-7-8. 152 lb down at 8-7-8. 152 lb down at 10-0-0, and 152 lb down at 11-4-4, and 152 lb down at 13-4-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1 00, Plate Increase=1.00 Uniform Loads (pIQ Vert. 4-21=-100.10-21--894,11-20=-10 Concentrated Loads (lb) Van: 16=38(F) 4=-3508 17=38(F) 21=-1689 22=-38(F) 23=38(F) 24=-38(F) Trapezoidal Loads (plf) Vert: 1=225-to-4=-328 WARNINO • Verify design parameters and READ NOrES ON IMS AND INCLUDED afITEX REFERENC PAGE aAll•70.1 rev. 10N2/2016 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual budding component, not a truss system Before use, the building designer must verify the applicable ty of design parameters and property Incorporate this design Into the overall building design BtscbV Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, sea ANSI/TP11 Ouallty Criteria, 03049 and SCSI Building component 6904 Parke East Blvd Safety Information available from Truss Plate Institute, 216 N. Lee Street, Suite 312. Alexandria, VA 22314 Tamps, FL 36810 Job Truss Truss Type 0ty Ply Park Sq/ PEMBROKE 23828-TRAY T13712248 PS02382A G3 FLAT 1 Reference o t o a Mid-Flonda Lumber, Bartow, FL. 2-1-8 G II I. 1 6x8 = 2 4x4 = 3 5x4 I I 8.130 s Mar 112018 Mrrek Industries. Inc. Fri Apr 6 11:48:24 2018 2-1-6 1.5x4 II 4x4 = axe = 4 5 6 Scale - 1:16.9 x10 = 11 10 9 4x4 = 8 5X = 5x5 = 4x4 = 7 12 3xl0 = 2-1-0 1.11.12 1-11.12 1-11-12 2-1.8 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) Udefl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 055 Vert(LL) -0.10 9.10 >999 360 MT20 2441190 TCDL 10.0 Lumber DOL 100 SC 0.78 Vert(CT) -014 9-10 >817 240 BCLL 00 Rep Stress Incr NO WB 0 63 Horz(CT) 0.02 7 n/e Na SCOL 50 Code FBC2017/TP12014 Matrix-R Weight, 165 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-9-2 oc purlins. 80T CHORD 2x6 SP No.1 BOT CHORD Structural wood sheathing directly applied or 10.0-0 oc bracing. WEBS 2x4 SP No.2 OTHERS 2x6 SP No.1 REACTIONS. ( lb/size) 12=5096/0-3-8, 7-3855/0-" Max Uplift 12=-1484(LC 4), 7=1121(LC 4) FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-12=-4303/1261, 1.2=748012178. 2-3=1057313077. 3.4=10573/3077. 4-5=10573/3077, 5-6=-6008/1747, 6-7=-3229/946 BOT CHORD 11-12= 437/1496. 10-11=-2178l7480, 9-10=3077/10573, 8-9=-1747/6008. 7-8=327/1123 WEBS 1-11=-1951/ 6705, 2-11=-3487/1032. 2-10=999/3437, 3-10=2160/647, 4-9=1805/543, 5-9=1478/5072, 5-8--3073/911, 6-8=1590/5473 NOTES- 1) 3-ply truss to be connected together with 10d (0.148"4") nails as follows: Top chords connected as follows. 2x4 - 1 row at 0-4-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0.9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise Indicated. 3) Wind: ASCE 7- 10, Vuft=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf: BCDL=3 Opsf; h=15111, Cat. 11; Exp 8; Encl., GCpi=0.18; MWFRS ( envelope) gable end zone: Lumber DOL=1.25 plate grip OOL-1.25 4) Provide adequate drainage to prevent water ponding. This Item has been 5) This truss hasbeendesignedfora10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20 Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2 0 wide electronically signed and will rd between the bottom chord and any other members. sealed by Lee, Julius, PE 7) Bearing at joint( s) 12, 7 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verity using a Digital Signature. capacity of bearing surface. Printed copies Of this p 8) Provide mechanicalconnection (by others) of truss to bearing plate capable of withstanding 1484 lb uplift at joint 12 and 1121 lb uplift at joint 7. document are not Considered 9) Girder carries tie- in span(s): 20-7-12 from 0-0.0 to 5-9-12: 19-1-4 from 0-0.0 to 10-2-4 signed and sealed and the signature must be verified LOAD CASE(S) Standard on any electronic copies. 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Julius Lee PE No. 34869 Uniform Loads (plf) MITek USA, Inc. fl CeR 8834 Vert: 1-4=1122(F=532, B=-490), 4-6= 590(B=-490), 7-12=-10 904 Parke East Blvd. Tampa FL 33610 Date: April 6,2018 Q WARNING • Verify design psnmerars and READ NOTES ON TWS AND INCLUDED MITEK REFERENCE PACE Mll•7473 ray. 1440343015 BEFORE USE. Design valid for use only with MlTekib connectors. This design Is based only upon parameters drown, and Is for an Individual building component, net a truss system Before use, the budding designer must verify the applicability of design parameters and property Incorporate this design Into the overall budding design. Bracing Indicated Is to prevent buckling ofindividual truss web ondfr chord members" Additional temporary and permanent tracing M iTek' Is always required for stabilityandtopreventcollapsewithpossiblepersonalInjuryandpropertydamageForgeneralguidanceregardingtitsfaWkation. storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, 038419 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Straat. Suhe 312. Alexandria, VA 22314 Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sy PEMBROKE 23828-TRAY T13712247IPS02382AG4FLOOR11 job Reference toollonall Mid -Florida Lumber, Bartow, FL. 8.130 s Mar 112018 MTek Industries, Inc Fri Apr 6 11:48 24 2018 Page 1 I D.gDsyMaeF6w5OyGn6ZCkOK3y3nnR-pUGCectiH6GgwmJASIXwU9DS_MHeeODLnVnzTSOb 2.5.4 2.5.4 3x4 = 2 1.5x4 2x4 II 4x4 = 5 Scale = 1 9.5 LOADING (psf) TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 5.0 SPACING- 1-0-0 Plate Grip DOL 1.00 Lumber DOL 1.00 Rep Stress Incr NO Code FBC2017rTP12014 CSI. TC 0.09 BC 0.22 WB 0.00 Matrix -MP DEFL. in Vert(LL) -0.00 Ven(CT) -0.01 Horz(CT) 0.00 loc) Well Ud 3-4 >999 360 3-4 >999 240 3 n/a n/a PLATES GRIP MT20 2441190 Weight. 14 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No 2 TOP CHORD Structural wood sheathing directly applied or 2-5.4 oc purlins, 80T CHORD 2x6 SP No 2 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Structural wood sheathing directly applied or 10-" oc bracing. REACTIONS. (lb/size) 4=390/0-3-8.3=390/Mechanical FORCES. (lb) - Max. Comp /Max Ten. - All forces 250 (lb) or less except when shown NOTES- 1) Refer to girder(s) for truss to truss connections. 2) Girder carries tie-in span(s): 13-6-4 from 0-0-0 to 2-5-4 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0 131" X 3") nails. Strongbacks to be attached to wells at their outer ends or restrained by other means. 4) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced) Lumber Increases 1.00, Plate Increase=1.00 Uniform Loads (plr) Vert: 3-4-314(F=-309), 1-2=50 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 34669 Well: USA, Inc. FL Ceft 6034 6204 Parke East Blvd. Tampa FL 33610 Date: April 6,2018 AWARNING - Varily design parameters and READ NOTES ON INS AND INCLUDED WrEK REFERENCE PAGE 1108-7412 rev. IOM312015 BEFORE USE. easeas Oeslgn valid for use only with MITek® connectors This design Is Dosed only upon parameters shown, and Is for an Individual building component, not e a trues system Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overact Dullding design. Bracing Indicated Is to prevent bueMing of Individual truss web and/or Card members only Additional temporary and permanent bracing M iTe k' Is always required for stability and to prevent collapse with possible personal Injury and property damage For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPH Quality Criteria, OSS-ee and SCSI Building Component 6004 Parke East Blvd Safety Information available from Truss Plate Institute, 210 N. Lee Street. Suite 312, Alexandria. VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382E-TRAY T13712248 PS02382A H1 FINK 6 1 Job Reference o do a Mid-Flodda Lumber, Banow, FL. 8.130 a Mar 11 2018 MiTek Industries, Inc. Fri Apr 6 11:48:25 2018 Page 1 ID:RUpYTVXcE9zHNtbOXp4HTAy3nna-HggapyuK2POWYvuNOT28oiYFS00o0 7ASNkK1DzTSOa 111179 7.O 4 13 8 0 19-t t-12 + 27•tl0 2B 0 0, 1 0-0 7 0 4 6-5-12 8 S12 7.0.4 1.0-0 Scale = 1:47.3 4x8 = l$ 3x4 = 5x6 = 3x4 = 3x4 = 9.0-0 i 18-0.0 27.0.0 9.0.0 9-0-0 941-0 Plate Offsets (X.Y)- 18:0-3-0.0-3-01 LOADING (psQ SPACING- 2-04 CSI. DEFL. in loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 064 Vert(LL) -0.27 8-9 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 8C 0.93 Vert(CT) -0.40 8-9 >808 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.37 Horz(CT) 0.06 6 n/a Na BCDL 100 Code FBC2017frPI2014 Matrix -MR Wlnd(LL) 0.13 9-15 >999 360 Weight: 124 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-5.11 oc purlins BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 7-3-8 oc bracing. WEBS 2x4 SP No 3 REACTIONS. (lb/size) 6-1140/0.3-8, 2=1140/0.3.8 Max Horz 2=140(LC 10) Max Uplift 6=-359(LC 11), 2=359(1_C 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1888/840, 34=1707/843, 4-5=-1707/843, 5-6=-1888/840 BOT CHORD 2-9-615/1642. 8-9=-291/1091. 6-8=-615/1642 WEBS 4-8=287/663, 5-8=406/328, 4.9=-287/663, 3-9=406/328 NOTES- 1) Unbalanced roof live loads have been considered for this design 2) Wind: ASCE 7-10. Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h-25ft; Cat. II; Exp B; Encl. GCpi=0.18, MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate gnp DOL=1.60 3) This truss has been designed for a 10 0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL - 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 359 lb uplift at joint 6 and 359 lb uplift at joint 2. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Jullue La PE No. 34669 Wek USA. Inc. FL Cert 66U 204 Parke East Blvd. Tampa FL 33610 Date: April 6,2018 Q w—No • Vartty design parameters and READ NOTES ON TMS AND INCLUDED A9TEK REFERENCE PAGE A61.7471 rev. t&W4016 BEFORE USE. Design valid for use only with MITekS connectors. This design Is based only upon parameters Shawn, and Is for an Indhrldval building component. not a truss system. Before use, the building designer must v" the applicability of design parameters and property Incorporate this design Into the overall buaNng design Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only Adddlenal temporary, and permanent bradng M iTe k' Is always required for Stability and to prevent collapse with possible personal Injury and property damage For general gutaana regarding the fabrk:alon, Storage, delivery, erection and bracing of trusses and truss systems, sea ANSVrPl1 Quality Cdtada, OSS49 and SCSI Building Component 6904 Parke East Blvd safety Information available from Truss Plata Institute. 218 N Lee Street. Suite 312. Alexandria, VA 22314. Tampa. FL 36810 Job Truss Truss Type Oty Ply Perk Sq/ PEMBROKE 2382E-TRAY T13712249 PS02382A J7 JACK 16 1 Job Reference ial Mid-Flodda Lumber. Bartow, FL 1-0-0 3x4 = 0-0 8.130 a Mar 11 2018 MiTek Industries. Inc. Fri Apr 6 11:48:26 2018 Page 1 ZxVgdnsOUv3nnP-IsOzl lvzpiWNA3TZ_AZNwv4PGoRWIWBJh 1 TtZgzTSOZ Scale = 1.22.3 LOADING (pso SPACING- 2-0-0 CSI. DEFL. in loc) Udell Ud PLATES GRIP TCLL 20.0 Plate Grip OOL 1.25 TC 0.70 Ven(LL) -0.10 4-7 >836 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.52 Vert(CT) -0.24 4-7 >349 180 SCLL 00 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a n/a BCOL 10.0 Code FBC2017/TP12014 Matrix -MP Wind(LL) 0.14 4-7 >580 360 Weight: 24 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing REACTIONS. (Ib/size) 3-183/Mechanical, 2=342/0.7.8, 4=90/Mechanical Max Horz 2=175(LC 10) Max Uplift 3=-135(LC 10), 2=-98(LC 10), 4=-8(LC 10) Max Grav 3=183(LC 1), 2=342(LC 1). 4=129(LC 3) FORCES. (lb) - Max. Comp /Max Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10: Vuh=140mph (3-second gust) Vesd=108mph, TCOL=4.2psf; BCDL=3.Opsf; h=25ft; Cat II; Exp B; Encl., GCpi=0.IS; MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces 6 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL-1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads 3) ' This truss has been designed for a live load of 20 Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 135 lb uplift at joint 3, 98 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius lee PE No. 309 IdiiTek USA, Inc. FL Cart 6634 6904 Parke Eau Blvd. Tampa FL 33610 Date: April 6,2018 QWARNING - VwHy design pemmetera and READ NorE3 oN 7k0S AND INCLUDED NITEK REFERENCE PAGE NIf-7473 rw. 1W341018 BEFORE USE. Design valid for use only with MReke1 connectors This design is based only upon parameters shown, and la for an Individual building component• not e truss system Before use, the building designer must verify the applicablkty of design parameters and property Incorporate this design Into the overall budding design. Bracing Indicated Is bo prevent buckling of Individual trussss web andlor chord members only Additional temporary and permanent bracing M iTek' Is always required for stsbaey end to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses end truss systems, sae ANSVIPI1 Quality Crltede. OS829 and SCSI Building Component 6904 Parka Fast Blvd. Safety Intormetlon available from Truss Plate Institute. 218 N. Lee Street. Suite 31Z Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply Perk Sq/ PEMBROKE 2382&TRAY T13712250IPS02382AKJ7MONOTRUSS41 ReferenceJobi Mid -Florida Lumber, Banow. FL. 8.130 s Mar 11 2018 MfTek Industries, Inc. Fri Apr 6 11:48:27 2018 Page 1 ID:4oY5 ch8PrUepjWhEKl5yiy3nnO-D3yLEdwbalfEnD21Yu4cT7dczCoDUlaTvhDR66zTSOY 1.5-0 54-0 9.10.13 1.5-0 54-0 46.13 l 2x4 = 1.bx4 u 5 3x4 = Sale - 1,210 54-0 46.13 LOADING (psf) SPACING- 2.0.0 CSI. DEFL. in loc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.58 Veri(LL) 0.03 7-10 999 360 MT20 244/190 TCOL 100 Lumber DOL 125 SC 0.49 Ven(CT) 0.07 6.7 999 ISO BCLL 0.0 Rep Stress Incr NO WB 0.37 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MR Weight 42 lb FT - 04/6 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=416/0-7-8. 5=399/Mechanical, 4=244/Mechanical Max Horz 2=227(LC 4) Max Uplift 2=-149(LC 4), 5=126(LC 8), 4=184(LC 4) Max Grav 2=416(LC 1), 5=399(LC 1). 4=255(LC 18) FORCES. (lb) - Max Comp /Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-810/180 BOT CHORD 2-7=352/760, 6.7=352/750 WEBS 3.7=0/275, 3-6=-821/385 BRACING - TOP CHORD Structural wood sheathing directly applied or 6.0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 9-11-5 oc bracing. NOTES- 1) Wind. ASCE 7-10; Vult=140mph (3-second gust) Vesd=108mph; TCOL=4.2psf; BCDL-3 Opsf; h=25ft; Cat II, Exp B; Encl., GCpi=0.18; MWFRS (envelope) gable end zone; Lumber DOL=1.60 plate grip DOL=1 60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3.6.0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 149 lb uplift at joint 2, 126 lb uplift at joint 5 and 184 lb uplift at joint 4. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B) LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase-1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2-60 Trapezoidal Loads (plf) Vert: 8-0(F=10, 8=10)•to-5=49(F=-15, B=15), 2=0(F=30, B=30)-to-4=-148(F=44, 8=44) This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lee PE No. 14669 Wilk USA, Inc. FL Cart 669/ 6904 Parka East Blvd. Temps FL 33610 Date: April 6,2018 WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAOE 1114I1.7473 rev. I"MOIS BEFORE USE. wwww Design valid for use only with MITak® connectors. This design 1t bated only upon parameters shown, and Is for an Individual building component, nor a truss system Betore use, the building designer must verify the applbebikty, of design parameters and properly Incorporate this design Into the overall budding design Bracing Indicated is to prevent buckling of Individual truss web and/or chard members only. Adddlonal temporary and permanent bracing M iTe k' Is always required tot stability and to prevent collapse with possible personal Injury and property damage For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, tee ANSVMII Quality Criteria, OSS49 and SCSI Building Component 6904 Parke East Blvd Safety Information available from Truss Plate Institute. 218 N. Lee Street, Subs 312, MexandAa, VA 22314 Tampa, FL 36610 Job Truss Truss Type DIV Ply Park Sq/ PEMBROKE 2382E-TRAY T13712251 PS02382A L1 GABLE 1 1 I Job Reference (optional) Mid -Florida Lumber, Barlow, FL. 364 4x4 = 8.130 s Mar 112018 MiTek Industries, Inc Fd Apr 6 11:48.27 2018 364 2x4 = 2x4 = 1-0-0 Scale-1:18.8 1$ 364 364 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In loc) Udell L/d PLATES GRIP TCLL 20.0 Plate Grip OOL 1.25 TC 0.24 Verl(LL) -0.00 2-6 >999 240 MT20 244/190 TCDL 100 Lumber DOL 1.25 BC 0.16 Vert(CT) -0.01 2-6 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.06 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix-P Wnd(LL) 000 6 >999 360 Weight 28 lb FT - 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 10-" oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=339/0-3.8, 4=339/0-3-8 Max Horz 2-44(LC 10) Max Uplift 2=-118(LC 10). 4=-118(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown TOP CHORD 2-3=-328/148, 3-4-328/148 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat II; Exp B, Encl.. GCpi=0.18: MWFRS (envelope) gable end zone and C-C Exlertor(2) zone;C-C for members and forces & MWFRS for reactions shown, Lumber OOL=1.25 plate grip DOL-1 25 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10 0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tell by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 118 lb uplift at joint 2 and 118 lb uplift at joint 4. 8) Truss Is designed with, and confirms to the 2007 Florida Building Code w/2009 supplements. This Item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Julius Lot PE No. 34660 MITak USA, Inc. FL Cart 66U 6604 Parka East Blvd. Temps FL 33610 Date: April 6,2018 QWARNING . verify design parameters and READ NOTES ON TIMS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10N312016 BEFORE USE. seesee Oesign valid for use only with MlTek* connectors. This design Is based only upon parameters shown, and Is for an Individual budding component, not Ituaa system. Beira use, the building designer moat verify the applicability of design parameters and properly Incorporate this design Into Ina overall design Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only Additional temporary and permanent bracing M iTek' is: ding If always required for stablldy and to prevent Collapse with possible personal Injury and properly damage. For general guidance regarding the fabrication, storage, delivery, arectlon and bracing of trusses and truss System$, we ANSVTPl1 Quality Criteria, OS1349 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Ttuss Plate Inatllule, 218 N Los Street, Suite 312. AlexandM, VA 22314 Tamps, FL 3WI0 Job Truss Truss Type Oty Ply Park Sq/ PEMBROKE 2382B•TRAY T13712252 PS02382A L2 KINGPOST 1 Job Reference (optional Mid-Flonda Lumber, Bartow, FL. 8.130 s Mar 11 2018 MiTek Industries, Inc. Fn Apr 6 11:48:28 2018 Page 1 I D:j7RObwW UOtim867TO72P8_/JoLI-iFVASzwOLKn5PNdy5bcr?K9vHb6i0Jgc8Ly_eYzTSOX 364 7-06 364 364 04 2 3x4 = Scale - 1.14.3 364 344 LOADING (psf) SPACING- 1-0-0 CSI. DEFL. In loc) I/de0 Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.10 Vert(LL) -0.02 1-4 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.60 Vert(CT) -0.04 1-4 >999 180 BCLL 0.0 ' Rep Stress Inca NO WB 0.44 Horz(CT) -0.01 1 n/a n/a SCOL 10.0 Code FBC2017/TPI2014 Matrix-P Wind(LL) 0.01 1-4 >999 360 Weight: 61 lb FT - 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0-0 oc purlins BOT CHORD 2x6 SP No.2 BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing WEBS 2x4 SP No.3 REACTIONS. (lb/size) 3-2367/0-3-8, 1=2799103-8 Max Horz 3=17(LC 12) Max Uplift 3=-403(LC 8), 1=-487(LC 8) FORCES. (lb) -Max. Comp /Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2655/458, 1-2=-2655/449 BOT CHORD 1-4=-378/2350, 3-4=-378/2350 WEBS 2-4=-364/2291 NOTES- (9) 1) 2-ply truss to be connected together with 1 Od (0.148"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0.9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-2-0 oc Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (8) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute any loads noted as (F) or (8). unless otherwise indicated 3) Unbalanced roof live loads have been considered for this design 4) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL-4.2psf; BCDL=3.0psf; h=15ft; Cat. 11; Exp B. Encl., GCpi=0.18; MWFRS (envelope) gable end zone; Lumber DOL=1 25 plate grip DOL-1.25 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tell by 240 wide This item has beenwillfitbetweenthebottomchordandanyothermembers. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 403 lb uplift at joint 3 and 487lb uplift at electronically signed and joint 1. sealed by Lee, Julius, PE 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1068 lb down and 179 lb up at using a Digital Signature. 6-7-0, 1068 lb down and 179 lb up at 4-7-0, and 1068 lb down and 179 lb up at 2-7-0, and 1692 lb down and 283 lb up at 0-7-12 on Printed copies Of illspbottomchord. The design/selection of such connection device(s) is the responsibility of others. 9) Truss is designed with, and confirms to the 2007 Florida Building Code w/2009 supplements document are not considered signed and sealed and the LOAD CASE(S) Standard signature must be verified 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 on any electronic copies. Uniform Loads (plf) Van: 1-3=10, 2-3=-30, 1-2=-30 Julius Lee PE No. UK9 Concentrated Loads (Ile) Mick USA Inc. FL Carl Vert. 5=-1692(F) 6-1068(F) 7=-1068(F) 8=1068(F) 6904 Parka East Blvd. Tamps FL 33810Oate: April 6,2018 Q wARN/No - Verity design parsmaters and READ NOTES ON TMS AND INCLUDED MITEK REFERENCE PAGE aUP7473 rev. t0Ai3/f01S BEFORE USE. Oeslgn valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a was system Before use, the building designer must vanly the applicability of design parameters and property Incorporate this design Into the overall budding design Bracing Indicated is to prevent bueldhV of Individual truss web and/or chord members ordy Additional temporary and permanent bracing M iTek' Is always required for stabday and to prevent Collapse with possible personal Injury and property damage For general guidance regarding the fabricallon. storage, delivery, erection and bracing of uussas and truss systems, see ANSVTPII Quality Criteria, OSS419 and BCSI Building Component 6904 Parke Fast BIM. Safety IMomtstion available from Truss Plate Institute. 218 N. Lae Street, Suite 312. Nexendda, VA 22314. Tamps, FL 36610 Symbols PLATE LOCATION AND ORIENTATION 3/4 Center plate on joint unless x, y offsets are indicated. Dimensions are in ft4n-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0';16 r For 4 x 2 orientation, locate plates 0- '114' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20120 software or upon request PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths Drawings not to scale) 2 TOP CHORDS O C1-2 C2a WEBS cc yiYt bc. a 0 H BOTTOM CHORDS JOINTS ARE GENERALLY NUMBEREDILETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERSILETTERS. PRODUCT CODE APPROVALS IMES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. 2012 MiTek® All Rights Reserved MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 A General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See SCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alterative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates an each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shag not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, sae, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that speed. 13. Top chords must be sheathed or purkns provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing. or less, if no ceding is installed, unless otherwise noted. 1 S. Connections not shown are the responsibility of others. 16. Do not cut or after truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. IS. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19, Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. CJ CJ 40.0-U 604 6-512 7-" 26.512 SO i as _E04 PARK SQ HMS / PEMBROKE 2382 - A 20 - HHUS46 FLR HGR 5 - HUS26 1-PLY HGR Mid Florida 6 1L O w U LL O 4C 4( b N 12-4-0 27$-0 I I I I I I I I I I I I I M10 ma 101m 11 I, 1 ATTIC ACCES, ATTIC ACCESS 11 a GARAGE 9-6-0 9408 11-0 0 oo 20.0-0 tf 1 Doke 13-4-0 04 Floor Loading TC Live: 40.00 psi TC Dead: 10.00 psi BC Live: 0.00 psi BC Dead: 5.00 psi TC Stress Inc: 1.00 BC Stress Inc: 1.00 Spacing: variable Roof Loading TC Live: 20.00 psi TC Dead: 20.00 psi BC Live: 0.00 psi BC Dead: 10.00 psi TC Stress Inc: 1.25 BC Stress Inc: 1.25 Spacing: 2- 0- 0 o.c. J1 J3 Account: Job: PS02382A Designer: Checker: Date: 10-05-17 RECORD COPY f D; City of Sanford Building and Fire Prevention Product Approval Specification For r 4z; DING` 1 8- 1 9 19 sc NFORD Permit # Project Location Address As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuildina.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Therma - Tru Single Door FL8871.5 Sliding MI Windows and Doors Series 420 Alum SGD - 2 Panel FL 15332.4 Sectional Clopay Building Products 94/T40-W4 FL15279.20 Roll U Automatic Other 2. Windows Single Hung MI Windows 8 Doors Series GA 185 Aluminum SH FL 17499.2 Horizontal Slider Casement Double Hun Fixed MI Windows 8 Doors Series GA 185 Alum Picture Fixed FL15349.1 Awning Pass Through Projected Mullions MI Windows 8 Doors 5764 Verical Alum Mullion FL 15353.2 Wind Breaker Dual Action Other June 2014 Category/Subcategory Manufacturer Product Descri tion(including Florida Approval # decimal 3. Panel Walls Siding James Harding Bldg Products Hardie Panel FL13223.2 Soffits Aluminum Coils, Inc Coils / Soffits FL12194.1 Storefronts Curtain Walls Wall, Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles IKO Industries, LTD Asphalt Shingles / Cambridge FL7006.1 Underla ments Warrior Roofing 15 and $30 Roofing Fell FL2346.1 Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofina tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coatin Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category/Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates En ineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Park Square Homes Please Print) June 2014 Florida Building Code Online 1 liups://www.floridabuilding.org/pr/pr_app_4ti.aspx?param=wGEVX . I tE RegulationProfessional r ras m SCIS Home I log in I user RegtstraWn I Not Thaim I Submt Surcharge I Stats Q Fads i PubrcatkM I F8C Stag I aCLS Ste Map I U*1 I Search I F ricUS h r 0oduct Approval usea: Public user i? @ll & Aoaoval Menu > Product pr A{I„r,n•I, > &WkAtbn & > AppGmtion Detail FL # FL8871-R8 Application ' type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Therma-Tru Corporation Address/ Phone/Email 118 Industrial Drive Edgerton, OH 43517 419) 298-1740 rickw@rwbldgconsultants. com Authorized Signature Vivian Wright rickw@rwbidgconsultants. com Technical Representative Address/ Phone/Email Quality Assurance Representative Address/ Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Dale 12/31/2021 Validated By Ryan J. King, P.E. Validation Checklist - Hardcopy Received Certificate of independence FL8871 R8 COI (b) CertlJttat Lindsp_e Ql 45: Referenced Standard and Year (of Standard) Standard Hear ASTM D1929 1996 ASTM D2843 1999 ASTM 063S 2003 ASTM E1300 1998 ASTM E84 2000 ASTM G26 1995 TAS 201, 202, 203 1994 I of 4 4/ 15/2018, 5:00 PM Florida Building Code Online https://www.floridabu ildiiig.org/pr/pr_app_dtl.aspx?param=wG E V X... Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending F8C Approval Date Approved Florida Licensed Professional Engineer or Architect EWjZ; R$ E ugIv (b) Egulvaiency of Standards.odf Method 1 Option D 10/17/2017 10/17/2017 10/19/2017 12/12/2017 Summary of Products fL !t Model, Number or Name Description 8871.1 a. "ClasslcCraft Rustic" Series 3'6 x 8'0 "Impact" Opaque Fiberglass Radius Top Single Door i ( X) - Inswing or Outswing i Limits of Use Installation Instructions i Approved for use In HVH2: Yes FL8871 R8 1I (b) Inst 8871.1.pdf Approved for use outside HVH2: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.1 for Design Pressure Ratings by F0871 R8 AE L) Ev_al 8871.1.p_df specific Model and for any other additional use limitations Created by Independent Third Party: Yes and Installation instructions.---- r—--_ 1 - — _ - -- _--- — - 8871.2 -_ b. "ClassicCraft" or "ClassicCraft 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door (X) - - Rustic" Series - Inswing or Outswing — - Limits of Use - Installation Instructions Approved for use in HVH2: Yes f18871 R8 1[ (b) Inst 8871;2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes f Design Pressure: N/A Evaluation Reports Other: See INST 8871.2 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.2.pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation Instructions- -- - - - — - - -- -- -- — — 8871.3 , c. "ClassicCraft" or "ClassicCraft I Rustic" Series Limits of Use Approved for use in HVH2: Yes Approved for use outside HVH2: Yes i Impact Resistant. Yes Design Pressure: N/A Other: See INST 8871.3 for Design Pressure Ratings by specific Model and for any other additional use limitations and installation Instructions. (For FlberClassic and SmoothStar sidelites, this product approval requires the use of "Y part numbers for these sidelites, which have been I stained or painted within six months of Installation.) 8871.4 d. "ClassicCraft" or "ClassicCraft Rustic" Series Limits of Use Approved for use in HVH2: Yes Approved for use outside HVH2: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 8871.4 for Design Pressure Ratings by specific Model and for any other additional use limitations and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of ' T part numbers for these sidelites, which have been 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door with Sidellte (OX or XO) - Inswing or Outswing Installation Instructions FL8871 R8 11 (b] Inst 8871.3.134f Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL8871 R8 AE (b) Eval 6871.3.0f Created by Independent Third Party: Yes 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door with Sidelites (OXO) _Inswing or Outswing _ --- Installation Instructions FL8871 R8 If (b) Inst 8871.4.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL8871118 AE (b) Eval 8871.4.g_df Created by Independent Third Party: Yes 2 of 4 4/15/2018, 5:00 PM Florida Building Code Online https:HwNvw. floridabu ilding.org/pr/pr_app_dtl.aspx?param=wG EV X.:. stained or painted within six months of Installation.) 8871.5 e. "FlberClassic" or "SmoothStar" 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door (X) - Series _ - - — - 7TInswing or Outswing- iLimits of Use i Installation Instructions Approved for use in HVHZ: Yes ELa$71 R8 11_(b) In$t 0 71.S.pdf l Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant., Yes Created by Independent Third Party: Yes Design Pressure: N/A , Evaluation Reports Other: See INST 8871.5 for Design Pressure Ratings by I FL8871Jt8 AE (bl Eval 8871.! .gdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation Instructions. 8871.6 f. "FiberClassic" or "SmoothStar" 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door with Series Sldelite (OX or XO) - Inswing or Outswing ILimits of Use Installation Instructions Approved for use in HVHZ: Yes MW2-8-8 1UbJ_In5SQ_Q71.6.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.6 for Design Pressure Ratings by EL,8Q71 RQ AE_(tt) Eval 8871 _6_pGf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation Instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of I* part numbers for these Sidelites, which have been stained or painted within six months of Installation.) 8871.7----- g. "FiberClassic" or "SmoothStar" 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door with - Series Sidelites (OXO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes EI.,8Q71 R8 LI (b)_IpS_ $ 7g1.7.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.7 for Design Pressure Ratings by F•L8871 R8 AE_(b) Eval 887.1.7.pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar Sidelites, this product approval requires the use of "1" part numbers for these Sidelites, which have been IstainedorpaintedwithinsixmonthsofInstallation.) 8871.8 h. "FiberClassic", "SrnoothStar", 6'0 x 8'0 "Impact" Opaque Fiberglass Double Door (XX) - ClassicCraR" or "ClassicCraft Inswing or Outswing Rustic" Series Limits of Use — Installation Instructions Approved for use in HVHZ: Yes F18871 R8 Il (b) Inst 8871.8.Qdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant, Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.8 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.8.pd1 specific Model and for any other additional use limitations Created by Independent Third Party: Yes i and installation Instructions. 1 8871.9 I. "FiberClassic", "SmoothStar", i "ClassicCraft" or "ClassicCraft I Rustic" Series 60 x 8'0 "Impact" Opaque Fiberglass Sidelites (OXXO) - Inswing or Outswln Double Door with Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871-_RgIt (b)Jnst 8821.9_RCLf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.9 for Design Pressure Ratings by I FL8871-ke E1bL v_al 0871,p l f specific Model and for any other additional use limitations I Created by Independent Third Party: Yes and installation instructions. (For FlberClassic and SmoothStar sidelites, this product approval requires the use of "1" part numbers for these sidelites, which have been stained or painted within six months of installation.) 1 ---- Back next 3 of 4 4/ 15/2018, 5:00 PM Florida Building Code Online li tps://www.tloridabuilding.org/pr/pr_app_dti.aspx?parim=%vGEVX... Contact Us :: 2601 Mir Stone Road, Tallahassee FL 32399 eh;MASO.487-1824 The State of Florida is an WEED employer. QpyAaM 2007.2013 State pf Florda.:: Prval;y StitgnjClt :: AccesSWay Statement :: Refund Statement Under Florida taw, emad addresses are public records. If you do not went your emad eddness released In response to a public -records request, do not send electronic mail to this enity. instead, contact the office by phone or by tradtlonal mall. ff you have arty questlons, please contact 8SO.487.139S. 'Pursuant to Section 4SS.27S(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4SS. F.S. must provide the Department than emad address f they have one. The emaas provided maybe used for offetal communlcatlon with the licensee. However emad addresses are public record. If you do not wish to buppty a personal addreSS, please provide the Department with an emal address which can be made avalable to the public. To determine (you area licensee under Chapter 4SS, F.S., please dick hM. Product Approval Accepts: Iowa Credit Card Safe 4 of 4 4/ 15/2018, 5:00 PM THERMAITRU 0 THERMA TRU DOORS 1 IS INDUSTRIAL DR.. EDGERTON. OH 4351 7 SMOOTH STAR & FIBER CLASSIC FIBERGLASS SINGLE 'IMPACT' DOOR w/ "NON -IMPACT' SIDELITES INSWING / OLITSWING GENERAL NOTES I. This producl has been evaluated and Is In compslonce with the loth Edition 12017) Rondo Building Code (FBC) structural requirements Including the'lio Velocity Hutricone Zone' (HVHZ)• 2 Product anchors shall be as hied and spaced as shown on detoils. Anchor embedment to base material stall be beyond wall dressM or stucco. 3. When used in ths'WKr the opaque door complies W ilh Section 1626 of the Fbido Builft Code and does not require an impact resistant covering. The nor impoct dMte must be protected with an Impact resistant covering comptying with Section 1626 of the FBC. 4. When used in areas outside of the 9iVHT regseMg wind bome debris protection. The opaque door compiles with FBC Sections 1609.I I & 13012.12 and does not require an impact resistant covering. The opaque door meets missie Ievel-D' and Includes Wind Zahe 4 as defined In ASTM E 1996 and FBC Sections 1609.122 6 R3D12.12-1. The nontrnpocl slde6fe3 mud be protected with an Impact resistant covering complying with FBC Sections 1609.12 A R30111.2. S For 2x stud framing construction, anchoring of these units shag be the some as that shown for 2( buck masonry construction. 6. Ste condltlons that deviate from the defats of Iha drawing require further engineering analysis by a gcersed engineer ar registered architect. 7. Oubwing conf9uro6om using coosld sit Dem 04 under active doors, and at sit used under the sldeStes. meet water lnfdfration requirements for?gVW. 8. kswing confgseatfors and oulswirg configuroslons using A Item AS under the door do not meet the water Ingirotionrequirementsfdtthe •IWW and shag be Installed only In non•hobllable areas or at habitable locations protected by on Overhang of canopy such that the angle between the edge of canopy or overhang to s8'is less than 45 degrees. TABLE OF CONFENIS design pressures I: general notes detain (Smooth star) RSHEETMIDI. ESCJUFWNatiors. det ds (Fiber classic( el detaGsrass sections sections 7 Vefficdl sass secfrors 8 Buck and home anchonno - 2X buck masonry construction 9 Frame axtw g -1 X buck masonry construction to Can enh a Gloarh defogs I I Bug of Moteriats 71.75' MAX.OA. FRAME WIDTH %,, ''••. 37.7SMAX. 1550 MAX.'i FRAME WIDTH FRAME WIDTH rwrrrrt 11 36r)Q MAX. 13.75'MAX. PANEL WIDTH PANEL WIDTH N V E 5 z = T P O f T JY OVERALL - DESIGN PRESSURE (PSG I DOOR TYPE , SWING " FRAME;:; - DIMENS)ON-- P.OSITIVE NEG:4TIVE_ INSWING 71.75" x 98.00' 60.0 60.0 SMOOTH OUTSWING 71.75" x 96.SW 65.0 65.0STAR INSWING 71.75" x 98.00' 60.0 60.0 F18ER OUTSWING 71.75' x 96.50' 65.0 65.0CLASSIC See Sheol 10 for desgrh Pressure Imracas. 0 n O y5h 6a aY 2r 2000 O u••z Y ii Z Cl m 0 of Salo& o f m d LL Z 0o Wd 9 a i s W fna— oa 05 22/08 i e N.LS. 4 e+ DWS m' er LFS 3 sure rq: i FL-8871.7 a 7 of 11 0 L O AA 47 41EXTERIOR as INTERIOR rl-\H0RJZ0NTALCROSS SECTION D- cTAJLA -A J i DM PAM 00000000 0000000000000000000000000000000000000000000000000001a.. 0000000000000000000 0000 0000000000000 0 00000000 1 0000000 000000000000000000000000000000000000000000000011, DETAIL A -A POW rebdorcenien) Do 2& 66% OPEN AREA MAX EXTERIOR INTERIOR 47 CAL CROSS SECTION dir r er DWS er LFS FL-- 887t.7 64 66 67 61 EXTERIOR 67 INTERIOR 1 HORIZONTAL CROSS SECTION 3 L— DETAIL A A J 60 DOOR FIbC 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000 0 00000 000000000000000000000000000000000000000000000 0000.0. 00000,000 DETALL A -A POnel f81t1101Ce11fEflt 4.07-1 tYP.1 rl CORNERSMHOF PANEL c H 110 sz ro RA L @-,QMM lo 4q.4t 28.86% OPEN AREA MAX. EXTERIOR INTERIOR 2 VERTICAL CROSS SECTON 3 Ell-I2:5I1I 1 1= C r-In N O 05 22 08 0z e N.M er DW$ 0 w+ LPs 3 w0 ND. e a FL-8871.7 0 N T 3 OILl A 13,IS' 1, PANEL WID1H I ' 1 v rL d P L 7D S1D A E 71 tn tta Sltleite 72 SideDe O F 73 S+deRe 6t r MAX D.L, DQEWOR ZY INMOR U 1 HOWONTAL CROSS SECTION 4 Idassx crott a moic) D.L. N IMERIOR 2 HORIZONTAL CROSS SECTION 4 (Fbw clomieI 1' MAX. D.L EXTERIOR INTEWR 3 HOMONTAL CROSS SECTION q (Smooth 0-1 EXTERIOR INIE1t10R O EXTERIOR 8 IN MIOR EXTERIOR t A. C: n r A• J=r; 0:05 i 47 49 r` V 4 a n 4 VERWAL CROSS SECTION 5 VERRCAL CROSS SECTION 6 VERiICAI CROSS SEC"ON 4 )mom aaF1 a rustic) 4 (Rbe d k) 4 (Smooth stor) p'N4Qoo 20 pzo OS 22 O8 7 s N.T.S. or. DWS m W. LFS ; R40 No_ V 0 FL-8871.7 0 o -C oa 1L n NOTE: 1. S•rdelite ass'y fastener: 6' from each end and 6 more screws equally spaced between. 8 screws total per jamb.) T HORIZONTAL CROSS SECTION kl-!,/ g stwd - Inswing 2 HORIZONTAL CROSS SECTION S a,lswo,g slwnm - ir-*v ado opptovetl 4 HORIZONTAL CROSS SECTION Slwwnw/IXsvDb1a 3'N HORIZONTAL CROSS SECTION Q,j -inswing 1=14491si . I I i Iffiziu OS 22 08 i t N.T.S. M, Dn is er In 3 FL-8871.7 u n 5 ar I t EXTERIOR y INTERIOR T VERTICAL CROSS SECDON 6 Eldrd - inswing EXTERIOR INTERIOR I EXTERIOR " T`... INTERIOR 2 VERTICAL CROSS SECTION 6 Shown w/Ix wl>budc EXTERIOR INTERIOR I ll-/ see gerd notes shee2 O o0 j O m INTERIOR n g u xis z Po v R m g p o a i 40 un 60 0 F:, e> 3 VERTICAL CROSS SECTION 6 Outswingconfip Wn see ggeenner' noises 9ree1 1 fa1IVIITwder tni'iltmtion requhements INTERIOR EXTERIOR we oeneml notes sheer 1 9I, 11hhl 1 1= Ile1. 4 e i OS 22 08 i E N.r.& s 9Y: UWS e.: LFS i FL- 8871.7 0 n 6 a 11 n SEE h 70 NOTE 1 9 8 0j EXTERIOR INTERIOR T VERTICAL CROSS SECTION Ou tswin9 01awn . Inswing oho appoved NOTE: 1. Screws tW head and sm lamb located 3• from each and and O.C. (IYP.) Ine. EXTERIOR INTERIOR 4 VERTICAL CROSS SECTION 7 u ing conOwm- EXTERIOR-%1— INTERIOR 2 VERTICAL CROSS SECTION Shown w/Msub-mutt EXTERIOR rS'*N VERTICAL CROSS SECTION Cawing conrowallon INTERIOR INTERIOR ALL 111- SEE TE 70 3-'\ VERTICAL CROSS SEC vOuiswinqcanApwffon INTERIOR DMIOR a N.T.s. eLc DWS l.f'S FL-8871.7 7 7 a 11 r ir TYP. HEAD & MASONRY II JAMBS IIOPENING II II II II II II 2X BUCK-N, I 11-1 MULUONOWNFOR RMENCE II ONLY II II II II II II II II II II BUCK ANCHORING Tr—T R4MASONRY r- i 0 Tjl OPENING FRAME TYP. SILL TYP. ti 2)(BUCK I F MULLIONLT TYP. SILL A HINGE JAMB FRAME ANCHORING STRIKE JAM! Masonry 2X Wd construidlon CONCRETE ANCHOR NOTES 1. Concrete anchor tocalkwu of The comers may be odpAted to maintain the min. edge distance to mono )olnk Z Concrete anchor location; noted os'MA)L ON CENTER' must be o*Wed to matntoin the min. edge distance to ffort0ri0ift additional concrete anchors may be recluked to ensure Me "MAX. ON C&4Wdrftnston are not exceeded. 3. Concrete anchor table o:.:: l*---'- ANCHOR .NCHOR. 1 -. :, m IN.CLEMANCE Y ECd w T0 114* 2" TAPCON EICO C, U TRACON I WOOD SCREW ffiWALLAIKUN Ult.%. 1. Maintain 0 nqrdmwn AW edge d1slance, I* end dksfonce, & I- 0-c- SPGchg Of wood screws to prevent the splitting of wood. HINGE WAIL Z- XF a E54 it r W. 6 Z g1D. 90 i— xAtyyyU ILad S 0F1icmiUTCH A DEADBOLT DETAIL at, U15 gm FL- B871.7 THESE (2) ANCHORS REQ'D ONLY WHEN DP > 60.0 PSF MASONRY OPENING FRAME i1X BUCK F a TYP. sn.l K ( TYP. SILL HINGEJAMB fIL4MEANCHORING Masonry IX buck construction CONCRETE ANCHOR NOTES: 1. Corlaxete anchor locations of the comers may be adjusted to rtwbltoln the min. edge distance to morforjolnts. 2. Concrete anchor locations noted as MAX. ON CENTER* must be odlusfed to maintain the min. edge distance to mortarloints. additional concrete anchors may be required to ensure the MAX ON CENTER' dimension are not exceeded. a Concrete anchor table: MIN;CLEARANCE I-. S12f=%: EMBEDMENT: EIm4" 2" 4" TAPCON 1. wnnn er,,REW M4TALLAIION NOTES: Maintain o mfnMwn S/8"edge distance. 1"end distance. d 1"0.c spoc'ng of wood screws to prevent the spitting of wood• a I 61U O I SIRIRE JAMB 1 lox N d s rrrrl • I1111 171,```` t N i E omcc IATCH i DEADBOLTDRAIt HINGE DRAR Cal z 514111sl I I i ocsa e oo_ e _ _ n v^2 u° 05122108 i a N.T.S. en DYVS m' en LFS 3 nm xo: a FL-8871.7 0 0 matt r sas r 2 iHRES OLD 5.75 o ra a oLD stondord 214 rF J i i : 2D INSWING SIDELITESpneei I/T GLASS 3/4- THK. BRE — GLASS 1 /Ir TEMP. AIR SPACE 1 /8" TEMP. SWIGGLE GLAZING 24 SPACER ALNG DETAIL 1 Mi 7/16- GLASS WE G4 GI F1pA01 pbss L G 0 IL RESH Irovh+g selWdlust Nvnnp 6AAl( DESIGN PRESSURE I' THK. GLASS IX TEMP. AIR SPACE 1 /8- TEMP. SWIGGLE GLAZING SPACER E2= h 8 HE D t SID 1 bmD 21T--{ ci r I O 1 fG SIDSlD Spoca 7/16' GLASS BITE Gllo sd LNG IL 1 /T THK. GLASS 1 /8" TEMP. AIR SPACE 1 /T TEMP. 25'STEEL INTERCEPT SPACER it un en DINS or. LFS oa PW FL-8871.7 n 10 or JJ 111 A. "% u. z* scan 1.1.111 1``` O n D i A uN•• y I$ I 1/4X 2-1/4 R E a° 9 0 `oPFH 1/4" X 3-3/4 Florida Building Code Online https://www. floridabu i ld ing.org/pr/pr_app_dti.aspx?param=wGE V X... I HAp;Da CGriFTM4M OF G r a 4 42 ? Business 8 Professional Regulation '',, ` I parnno,a neovlva:a, osainrorgmua cc!rAtcpaPp SCiS Home , Log In I User Registration ! Hot Topr6 I Submit surcharge I Scats & Facts 1 Publications Fac staff i acts site Map I Inks search A rida r Product Approval R It USER: Pudk User HoAutl Annroval Meny > Pmgttt or ApgJ tbn 54drrh > e 0! lillp 64I > Application Detail Ft. # FL15332-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sltlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed LUIS Roberto Lomas the Evaluation Report Florida License PE-62514 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Steven M. Urlch, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code EL15332-_P_4 COI FLCOI.pdf Standard AAMA/WDMA/CSA 101/I.S.2/A440 Year 2008 I of 4/1512018, 5:03 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_otl.aspx?pamm=wGEVX,. Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 08/11/2017 08/13/2017 08/1S/2017 10/10/2017 Summary of Products FL # - Model, Number or Name - Desc-ription 15332.1 SERIES 420 ALUMINUM SGO SERIES -3/4"x80" NO420ALUMINUMSGOOXO145N- - REINFORCED- - - Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO APPROVAL DOCUMENT FOR DESIGN PRESSURE RATINGS- `_-----_-- 15332.2 SERIES 420 ALUMINUM SGD Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO APPROVAL DOCUMENT FOR DESIGN PRESSURE RATINGS 15332.3 SERIES 420 ALUMINUM SGD REINFORCED Limits of Use _ - --- Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure- N/A Other: REFER TO APPROVAL DOCUMENT FOR DESIGN PRESSURE RATINGS FL15332 R4 II Q8-00500E.od< Verified By: Luis Roberto Lomas 62S14 I Created by Independent Third Party: Yes ! Evaluation Reports FL15332_R4 E S108Q7Q.pdf — — Created by Independent Third Parry: Yes SERIES 420 ALUMINUM SGD OX, XO, XX 96"x80' NON - REINFORCED -- ---- Installation Instructions F_41i 32 4_Il_0049$-E,PS[ Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports Q05332 R4 AE 510805D.odf Created by Independent Third Party: Yes SERIES 420 ALUMINUM SGD REINFORCED OXO 145-3/4"x96" Installation Instructions EU5332_R_1t 0_Q2Z49C pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports F_LI5332 R4 AE_512% -8_CCSIf Created by Independent Third Party: Yes 15332.4 _ 1 SERIES 420 ALUMINUM SGD 1 SERIES 420 ALUMINUM SGD REINFORCED OX, REINFORCED 196'x96" Limits of Use - — - - Installation Instructions - -- - - - Approved for use in HVHZ: No FL15332 R4 11 08-02249C.pdt Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN F_15332 R4 AF 512969C. PRESSURE RATINGS Created by Independent Third Party: Yes 15332.S SERIES 420 ALUMINUM SGD - RE[NFORCED Limits of Use - - --__.- Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO APPROVAL DOCUMENT FOR DESIGN PRESSURE RATINGS 15332.6 SERIES 420 REINFORCED SERIES 420 REINFORCED ALUMINUM SGD OX, XO, XX ALUMINUM SGD 96"x96" Limits of Use Installation Instructions Approved for use In HVHZ: No ELI5 11 _R4 [[ OB-OQ499Epdf Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes SERIES 420 ALUMINUM SGD REINFORCED XXX 143"x96" Installation Instructions - F.LUX32 R4 f l Q$: Q2250C Pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FLl 3 R4 AE 51297Q.pdf Created by Independent Third Party: Yes 2 of 3 4/15/2018, 5:03 PM Florida Building Code Online https://www. floridabti i lding.org/pr/pr_app_dtl.aspx?param=wG EVX... Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN f t Si32 R4 AE 510ffi_M,pdf PRESSURE RATINGS Created by Independent Third Party: Yes i 15332.7 I SERIES 420 REINFORCED — SERIES 420 REINFORCED ALUMINUM SGD OXO 146"x96" ALUMINUM SGD Limits of Use --- Installation Instructions -- — --- - Approved for use in HVHZ: No E115332 R4 II W-QQ501E,pdf Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN EL15332 R4 AE S1Q_80BD.odf PRESSURE RATINGS Created by Independent Third Party: Yes 15332.8 1 SERIES 430/440 ALUMINUM SGO Limits of Use — Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO APPROVAL DOCUMENT FOR DESIGN PRESSURE RATINGS 15332.9 1 SERIES 430/440 REINFORCED i ALUMINUM SGD Limits of Use - Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO APPROVAL DOCUMENT FOR DESIGN PRESSURE RATINGS SERIES 430/440 ALUMINUM SGD XXX 143"x80" NON - REINFORCED Installation Instructions ELIS332 R4 If 08-00503E.14f Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports fL15332 R4 @ESa0809D,pdf Created by Independent Third Party: Yes SERIES 430/440 REINFORCED ALUMINUM SGD XXX 143"x96" Installation Instructions FL1S332—R4 11-08=00503E,Pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports RUM R4 AE 510810D.0f Created by Independent Third Party: Yes Bark Next Conlin. a :: 2601 8lalr Stone Read. Tallahassee FL 32399 P pne: 850.487-1824 The State of Florida N an AA/EEO empbyec copynotit 2007-aq L_St+1e of Florida- :: Epsy.2OjtaeOt :: Accessibility Statement :. fkllmdjcAatcal t Under Florida law, email addresses are pubic records. r you do not want your a -mar address released In response to a publik.records request, do not send electronic mar to this entty. Instead, contact the office by phone or by traditional mall 9 you have any questions, please contact 8S0.497.139S. -Pursuant to Section 4S5.275(1), Florida Statutes, directive October 1. 2012, kensees licensed under Chapter 4SS, F.S. must provide the Department with an emar address r they have one. The *mails provided may be used for omtlal communkalbn with the licensee However email address!$ are public retard. V you do not wish to supply a personal address, please provide the Oepartment with an email address which can be node available to the pubic. To determine R you are a licensee under Chapter 4SS, F.S., please tick b1R. Product Approval Aooepte: FOR dlKr Credit Card Safe 3 of 3 4/15/2018, 5:03 PM NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4. ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 5. FRAME MATERIAL- EXTRUDED ALUMINUM 6063—T5. 6. UNITS MUST BE GLAZED PER ASTM E1300-04/09 WITH SAFETY CLASS. 7. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 8. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WPM LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16. OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4-. 9. DOOR ASSEMBLIES INSTALLED WHERE OVERHANG RATIO IS EQUAL OR GREATER THAN 1.0 DO NOT REQUIRE WATER INFILTRATION RESISTANCE OVERHANG RATIO = OVERHANG LENGTH/OVERHANG HEIGHT 10. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8• MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS 11.FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4• MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 12.FOR ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 13. ALL FASTENERS TO BE CORROSION RESISTANT. 14. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD - MINIMUM SPECIFIC GRAVITY OF G-0.42 B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3.192 PSI. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). D. METAL STRUCTURE: STEEL 18GA. 33KSI OR ALUMINUM 6063-T5 .048" THICK MINIMUM 15. APPROVED CONFIGURATIONS: OX, XO, XX, XP, PX, XIP, FIX TABLE OF CONTENTS SHEET NO.1 DESCRIPTION 1 I NOTES 2 - 3 ELEVATIONS 4 - 10 INSTALLATIO I1rcv I OESCRFTM I DATE 1 APPROVED A ADDED FLANGE AND FIN INSTALLATION 12/10/13 ILL B REVISED INSTALLATION DETAILS 08/03/15 R.L. C REVISED INSTALLATION DETAILS 06/21/17 R.L. SIGNED: OS21/2017 MI WINDOWS AND DOORS LLC 0111111111// 650 WEST MARKET STREET GRATZ, PA 17030 NJ 419 G E N s . ,p 0 5 * = SERIES 420 SGD REINFORCEDWITHOUTADAPTER96" X 96" NOTES pTATE OF ; i F•• (OR10P• '' O/ONA1` laG mA1nr, D+ rc 10. REV V.LE 08-02249 C Luis R. Lomas P.E. FL No.: 62514 DATE NTS 10/30/13 021OF 10 LR09ER70LOMASPE 1492 WOODFORD AD LEWISVELE. NC 270M 474-64a4609 Abmarft4mAwaam I F1 HE 6' MAX 96" MAX FRAME WIDTH 2) ANCHORS PER LOCATION SEE CHART #3 FOR NUMBER OF LOCATIONS REQUIRED 17' MAX r I I Q.C. -1 6' MAX 17' MAX O.C. 16' I tAX AME IGHT 6' MAX 6' MAX SERIES 420 SGD REINFORCED WITHOUT ADAPTER EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING 35.OPSF NONE SEE CHARTS /1 AND 02 FOR OTHER UNITS RATINGS NOTES: 1. MAXIMUM PANEL SIZE: 491/Y x 9S' 2. MAX/MUM D.LO.: 44 58' x 90 &8' HARDWARE SCHEDULE MOUNTED HANDLE SET (99.04.145) AT 38 314' ON CENTER FROM PANEL 90 LLIC TANDEM ROLLERS (99.17.195) AT EACH END OF PXlEL BOTTOM RAILS 1M 6053.Te REINFORCEMENT (000) AT ALL PANEL INTERLOCKS tMVISDIS RLV DESCPoFl10N D4¢ AiVROrm A ADDED FLANGE AND FIN WSTALLATIDN 12,110/13 R.L. 6 REVISED INSTALLATION DETAILS 08/03/15 R.L. C REVISED INSTALLATION DETAILS 06/21/17 R.L. CHART rI WHERE WATER INFILTRATION RESISTANCE 1S REQUIRED. CtF ALM= a Q"rAT r Design press - chail (ps0 Frame Woe Panel and Total Frarre WatA (m) 1 30.0 8000 360 7200 420 84.00 4&0 98.00 P. I Nap I P. Np Pot Meg 84.0 40.0 58.4 40.0 509 40.0 42.0 SAO 40.0 552 40.0 4fl0 T40LO43.0 39.4 39.4 40.0 52.4 40.0 45.4 37.1 37.1 D40 400 49.8 4Q0 431 36.0 35.0 CHART I2 WHERE WATER INFILTRATION RESISTANCE IS NOT REQUIRED. SEE NOTE 9 SHEET I Design pressure chart (psq Frarna Stole Panel and Total Frame VWth t1) H*tg M 30.0 8R00 3&0 7200 120 scoo 4&0 9&00 Pas I Nay I os Nap Pot Nag Pot Nag 84.0 58.1 1 58.4 1 5D.9 509 45.7 45,7 42.0 420 8&0 M21 65.248.D 4&0 43.0 43.0 39.4 39.4 920 52.4 524 45.4 454 4" 40.8 37.1 37.1 96.0 49.8 49.8 43.1 43.1 38.4 14 35.0 35 0 CHART 03 Number of anchor locations required Frame Snye Rand and Total Frame V th in) He9h1 In!) 800 30.0 1 no 72.0 420 a 4&0 P&O HLS I Jamb I HaS I Jamb HAS I Jamb H&S bmb 84.0 4 1 e 1 5 1 e 6 1 8 6 a 85 4 e 1 5 0 e e e e 920 4 1 e 5 1 e e e 86 0&0 4 0 5 9 8 6 8 6 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 420 SGD REINFORCED WITHOUT ADAPTER 96" X 96" ELEVATION OPAWN. DWC NO REV V.L. 08-02249 C seat NTS JDAV 10/30/13 1 SHED OF 10 L. RMRTO LCMAS P.F. r432 wOODFORD RD LEKISVLL& NC 27023 434-m-o 09 rl ffAsv &%Aw tom SIGNED. 06/21/2017 09 / GENSF •LP ey8j25 '• o (TATl E OF O'. . w Luis R. Lomas P.E. FL No.: 62514 c M FR HE FLAT MOUNTED HANDLE METALLIC TANDEM ROLL 96' MAX FRAME WIDTH 1)•ANCHOR PER LOCATION AT HEAD do JAMBS SEE CHART 94 FOR NUMBER OF LOCATIONS REQUIRED 6.( 1L 17" MAX _ Ir O.C. 6 MAX 6' MAX 17' MAX O.C. 6' TT-, 4X WE GHT 6" MAX 2) ANCHORS PER LOCATION REVISIONS aVI OESOIP110N GATE APPROVED A ADDED FLANGE AND FIN wwALLATON 12/10/13 R.L. B REVISED INSTALLATION DETAILS 08/03/15 R L C REVISED INSTALLATION DETAILS 06/21/17 R.L. NOTES: I. MAXIMUM PANEL SIZE., 46 I/T x AS' 2. MAXIMUMDLO.:445.8'x9D&9• CHART fl4 Number of anchor locations required SkVb Panel and Total Una VVidIh (in) Frame HepM in) 30.0 60.0 30.0 720 2.0 4.0 0.0 0&0 H65 lamb N6S Jamb Hss Jamb NSS Jamb 6A0 4 6 5 6 8 1 6 6 6 80.0 4 6 5 6 6 6 6 6 910 4 6 5 6 6 6 6 8 90.0 4 6 5 8 6 6 6 6 SERIES 420 SGD REINFORCED WITHOUT ADAPTER AT SILL EXTERIOR VIEW SEE CHART #4 FOR NUMBER OF LOCATIONS DESIGN PRESSURE RATING IN.PACT RATING REQUIRED 335.0PSF NONE MI WINDOWS AND DOORS LLC SEE CHARTS IT AND #2 SHEET 2 FOR OTHER UNITS RATINGS 650 WEST MPA 17 STREET GRATZ, PA 030 SERIES 420 SGD REINFORCED WITHOUT ADAPTER 96" X 96" FIN ELEVATION OW'": a" NO. R V. L. 08-02249 ARE SCHEDULE 146) AT363(4'ON CENTER FROM PANEL BOTTOM $tN[ NTS a' 10 30 13 3 OF 10 E 195) AT EACH END OF PANEL BOTTOM RAILS L. AOBERD LLWIAS P.E I> Z ri'OOOFOAD AD EWLSVILLE. AC270t7 MS) AT ALL PANEL INTERLOCKS _ -__ 434-W-OM nbmast9aMmas?atom SIGNED: 06/21&017 IR! Itlo/% s . VGENS! q`P STATE • 0„ 61251 r OF • cZORMt• M10NAtill 11E G. Luis R. Lomas P.E. FL No.: 62514 SONS 1/2- MIN. REV DESC FWN DATE APPROVED EDGE DISTANCE A ADDED (LANCE AND FIN INSTALLATION 12/10/13 Rl B REVISED INSTALLATION DETAILS 08/03/1S R.L. 1 3/8" MIN. C REVISED INSTALLATION DETAILS 06/21/17 R.L. WOOD FRAMING OR 2X BUCK EMBEDMENT i BY OTHERS 1/4• MAX. SHIM g10 WOOD SPACE 1 3/8" MIN 4• MAX. SCREW EMBEDMENT IF'HIMSSPACE INTERIOR 1/ 2• MIN. EDGE DISTANCE r1 110 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS EXTERIOR 11 11 11 11 INTERIOR SILL TO BE SET IN A BED OF APPROVED SEALANT MIN. ENT 11N. VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FlNISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2 PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 g10 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS JAMB INSTALLATION DETAIL WDOD FRAMING OR 2X BUCK INSTALLATION SIGNED: 0621/2017 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET 0% IIII1/1/,, 0 GRAT2, PA 17030se; P ; I40yC 5 1 * = SERIES420SGDREINFORCEDWITHOUTADAPTER96" X 96" yv, FRAME INSTALLATION DETAILS SSTAT E OF OR1GUNTS oRAwN: owc No. AD 08Luis R. Lomas P.E. FL No.: 62514 o" h 10/30/13 =49 OF L ROBERTO LOM4S P.E. I/ 92 MIOODFORD RD LEK SV01E AC 27023 4ZU40460 doff SV*kM *c= METAL STRUCTURE BY OTHERS 1/2- MIN. j EDGE DISTANCE 1/4- MAX. B r SHIM SPACE OR LING SILL TO BE SET IN A BED OF APPROVED SEALANT 10 SMS OR SELF DRILLING SCREW METAL STRUCTURE BY OTHERS 1/2- MIN. EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: I. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED INACCORDANCEW/THASTM E2112 TT 1/2- ME EDGE DIST) I 110 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS RLVmORS REv orscRpne" DATE A PNOVm A ADDED FLANGE AND FIN INSTALLATION 12/10/13 RL 8 REVISED INSTALLATION DETAILS 08/03/15 R.L. C REVSED INSTALLATION DETAILS 06/21/17 RL JAMB INSTALLATION DETAIL METAL STRUCTUREWSTALLATON SIGNED: 0612112017 MI WINDOWS AND DOORS LLC juIIIIII/j,, 650 WEST MARKET STREET J\? .G fi 04fGRATZ, PA 17030 1 b, 9F •S DAt5SERIES420SGOREINFORCEDWITHOUTADAPTER 9X 96" INSTALLATION DETAILS 7• Of; ,*= TATEFRAME F • °C 0R10P • ' jsiS,01VA1`E G Luis R. Lomas P.E. FL No.: 62514 auwN 01rc ND. OB-022249 as C scut aTE NTS 10/30/13 5 OF 10 L ROBERTO LOMAS PZ IkVV0OOOFORDRDLEV4SVILLENC27= ViM- O509 rftffaL '+Y cm 1 1/2- MIN 1' MIN. SEPARATION EDGE DISTANCE 1 1/4' MIN. a• . ' EMBEDMENT CONCRETE/ MASONRY 1/4' MAXBYOTHERS SHIM SPACE OPTIONAL 1X BUCK TO BE PROPERLY SECURED SEE NOTE 3 SHEET 1 3/16- TAPCON 3/16- TAPCON MASONRY/ CONCRETE BY OTHERS EXTERIOR II II II II INTERIOR SILL TO IN A BED OF APPROVED`SSEALANT s 1 1/4' MIN. a' EMBEDMENT e 1 a 2 7/8- MIN 1- MIN. SEPARATION EDGE DISTANCE VERTICAL CROSS SECTION CONCRETE/MASONRY WSTAL LATION REWSOM OESpEPIION DATE APPROVED ADDED FLANGE AND FIN INSTALLATION 12/10/13 R.L REVISED INSTALLATION DETAILS 08/03/15 R.L. REVISED INSTALLATION DETAILS 06/21/17 R.L. 1 1/4' MIN. EMBEDMENT 1/4' MAX. 1- o SHIM SPACE MIN • INTERIOR EDGE DISTANCE 3N o MIN SEPARATION 3/16- TAPCON EXTERIOR CONCRETE/MASONRY BY OTHERS JAMB INSTALLATION DETAIL C4NCRETEQLL4SCNRY INSTALLATION OPTIONAL 1 X BUCK TO BE PROPERLY SECURED SEE NOTE 3 SHEET 1 NOTES. 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY 0771ERS TO BE DESIGNED INACCORDANCE WITH ASTM E2112 SIGNED: O6/21/2017 MI WINDOWS AND DOORS LLC xx%%IIII III" 650 WEST GRATZ. MPAKET17030REET `J S\GENS 9+% F SERIES 420 SGD REINFORCED WITHOUT ADAPTER - *• 0 5 ,< = FRAME INSTALLATION DETAILS Dom, $TAT OF oRAILN: or, NO. KV RIO a08-02249 SCALE NTS 1611E 10/30/13 JOW6 OF 10 //OIIIAIIt\\ L ROSERMLALISAS LDIS R. Lomas P.E. 4v VA2ODFORDRDLENTSNLLE.NC27X2 FL No.: 6251413V.60b-0FM .V:ORI r 1/2- MIN. EDGE DISTANCE WOOD FRAMING 1 3/8' MIN. OR 2X BUCK EMBEDMENT BY OTHERS 1/4" MAX. SHIM SPACE 10 WOOD SCREWS EXTERIOR LL LI LL_ll INTERIOR 0 BE SET IN I OF NED SEALANT 10 WOOD SCREW WOOD FRAMINC OR 2X BU0 BY OTHER! MIN. TENT LWL V I/YYI.L VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK I/VSTALIAi10N NOTES., I. BVTERIOR AND EXTERIOR FINISHES. BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 IIEVO WS D[scRmoN DATE APPBO m ADDED FLANGE AND FIN NSTALLATION 12/10/13 R.L. REVISED INSTALLATION DETAILS 08/03/15 R.L. REVISED INSTALLATION DETAILS 06/21/17 R.L. 1 3/8• MIN. 1/4- MAX. EMBEDMENT SHIM SPACE INTERIOR 1D MIN. EDGE DISTANCE R hP F=— c 10 WOOD SCREWS t-- EXTERIOR JAMB INSTALLATION DETAIL OR 2X BUCK WOOD FRAMING WOOD FRAMING OR2X BUCK INSTALLATION BY OTHERS SIGNED: 0&l21/2017 MI WINDOWS AND DOORS LLC V 11a Ilirrl//// 650 WEST GRATZ, MPAK170ET 30REET EN o5SA' ,. 612SERIES420SGDREINFORCEDWITHOUTADAPTERTATE FLANGEINSTALLATIONDETAILSZ10OF ; o Zc" ' cLORIOP• i!ip oarN: o>rc na IiEV V. L. 08-02249 C ONAL EaG` rrI1111110 Luis R. Lomas P.E. FL No.: 62514 SME NTS -m 10/30/13 ISHM7 OF 10 L ROBERTOLOIMSA& IA3v WOODFORD RD LFWLSVMLE AIC 27aM 434, 60.OW9 AbffA3dDkbm&%w-=m 1/2' MIN. EDGE DISTANCE METAL STRUCTURE BY OTHERS 1 /4" MAX. SHIM SPACE otse neN ate APPROlLD ADDED FLANGE AND FIN INSTALIATION 12/10/13 R.L. REVISED INSTALLATION DETAILS 03/03/15 R.L. REVISED INSTALLATION DETAILS 06/21/17 1 R.L. 1/d' MAX. SHIMSHIM SPACE SFORL- SEL DRILLINGSEL SCREW 1/2- MIN. INTERIOR EDGE EXTERIOR INTERIORFill DISTANCE SILL TO BE SET IN A BED OF 10 SMS OR APPROVED SEALANT SELF DRILLING SCREWS 10 SMS OR METAL STRUCTURESELFDRILLING BY OTHERSSCREW EXTERIOR METAL STRUCTURE BY OTHERS JAMB INSTALLATION DETAIL METAL STRUCTURE UJSTALIATION 1 /2' MIN. EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLA 7701V NOTES: 1. INTERIOR AND EXTERIOR FINLSHES. BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 06/21/2017 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET 111111II,,, J S R. LO,, GRATZ. PA 17030 G E Af '. + 0 51 +1r = o lai,coa_ SERIES 420 SGD REINFORCED WITHOUT ADAPTER 96' X FLANGE INSTALLATION DETAILS p TAT OF Lug 0 OF• cCOR10P• DRAW.DWG No. RCV C s l4 IG LUIB R. Lomas P.E. FL No.: 62514 scat08-02249 NTS ate 10/30/13 8 OF 10 L AWERTO LCUAS AE 74Y WOOOFCWRDLEYNSVUEAC27 7 43.W4s09 nAom bbm&ve mm REWSONS 1 1/2" MIN. 1' MIN. REV DESCFWTQN D= APPRWED SEPARATION EDGE DISTANCE A ADDED fLu+CE AND FlN INSTALLATION 12/10/17 R.L B REVISED MSTALIA71ON DETALS 08/03/15 R.L. I C REVISED INSTALLATION DETAILS 06/21/17 R.L. 1 1/4" MIN. CONCRETE/ ' e• •'e EMBEDMENT EMBEDMENT MASONRY 1/4' MAX BY OTHERS SHIM SPACE IOnBUCK ONAL- . 1/4" MAX. X TO BE .o ' r SHIM SPACE PROPERLY MIN . I INTERIOR SECURED EDGE SEE NOTE 3 DISTANCE SHEET 1 _ •• 3/16" TAPCON o' EXTERIOR INTERIOR MIN. SEPARATION o IL SILL TO BE SET IN o A BED OF 3/16" rAPcoN EXTERIOR APPROVED SEALANT 3/16" TAPCON CONCRETE/MASONRY JAMB INSTALLATION DETAIL BY OTHERS CONCRETE/MASONRYINSTALLAnON MASONRY/ OPTIONAL 1X BUCK CONCRETE TO BE PROPERLY BY OTHERS SECURED SEE NOTE 3 SHEET 1 NOTES: a 1 1.INTER/ORAND EXTERIOR FINISHES, BYOTHERS a, 1 1/4' MIN. NOT SHOWN FOR CLARITY. a' EMBEDMENT 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE a . • • . I DESIGNED IN ACCORDANCE WITH ASTM E2112 e' a SIGNED: 06/21/2017 MI WINDOWS AND DOORS LLC v11Rllylt/ 2 7/8' MIN. 1' MIN. 650 WEST MARKET STREET 5'C EN SEPARATIONEDGEDISTANCEGRATZ. PA 17030 , 'N e, ,J+ VERTICAL CROSS SECTION SERIES 420 SGD REINFORCED WITHOUT ADAPTER = *4TAT 05 1CONCREIE/INASONAYINSTALLATION96" X 96" FLANGE INSTALLATION DETAILS EE OF tl, DRWW. Dxc NO. 08- 02249 RLV s3 sca NTS o`7c 10/30/13 19 OF 10 /////ONA110 LAWRTOLOILASP. E Luis R. Lomas P.E. 00- M-06V9 fa "awbnlecmm 1432 WOODFORD RD LEVAWXLE, NC 27= FL Na.: 62514 WOOD FRAMING BY OTHERS 1 1/4" MIN. EMBEDMENT APPROVED SEALANT BEHIND FIN NB WOOD SCREW APPROVED SEALANT BEHIND FIN 18 WOOD SCREW 7/16" MIN EDGE DISTANCE EXTERIOR 1/4• MAX I SHIM SPACE 7/16" MIN EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4• MIN. EMBEDMENT WOOD FRAMING BY OTHERS INTERIOR TRIM 1/4' MAX. SHIM SPACE INTERIOR VERTICAL CROSS SECTION WOW FRAMING OR 2X BUCK INSTALLATION FOR SILL INSTALLATION SEE SHEETS 4•9. REVISIONS REV DESCRPWN DUE I APPROVED A ADDED FLANGE AND FIN INSTALLATION 12/10/17 R L B REVISED INSTALLATION DETAILS 03/03/15 R.L. C REVISED INSTALLATION DETAILS 06/21/17 R.I. 1 5/8' MIN. EDGE DIST, TRIM : ° 1 1/4" MIN. INTERIOR EMBEDMENT MASONRY/CONCRETE BY OTHERS u-5 1X BUCK BY OTHERS. HOOK STRIP 1X BUCK TO BE PROPERLY SECURED 3/16" EXTERIOR a i PANEL INTERLOCK HOOK STRIP INSTALLATION MASDNRY)CONCRETE 1/2" MIN. METAL STRUCTURE 1/2" MIN. EDGE DISTANCE BY OTHERS EDGE DISTANCE TRIM INTERIOR MIN. EMBEDMENT HOOK STRIP HOOK STRIP — I I 010 SELF DRILLING SCREW 10 WOOD PANEL SCREW EXTERIOR INTERLOCK EXTERIOR PANEL INTERLOCK HOOK STRIP INSTALLATION METAL SJHUCI UHE HOOK STRIP INSTALLATION SIGNED. 0612112017 2X BUCWWOOD FRAMING MI OWS DOOREETRS LLC 650Dw ESMARDE 5 GRATZ, PA 17030 GENs 9+ SERIES 420 SGD' REINFORCED WITHOUT ADAPTER zr* 14a 625 * = 96" X 96" NAILFIN Q HOOK IMSTALLATION DETAILS 7-pFTATE OF ; NOTES. EXTERIORI. INTERIORANDFINISHES, BY OTHERS, oRAtrtr oec No Rtv 0. i" •'° LpR1OP• 08- 02449 C pNAiitrt G NOTSHOWNFORCLARTIY. 2. PERIMETER AND JOINT SEALANT BYOT 14ERS TO BE SGu.E NTS MtE 10/30/ 13 1 O OF 10 DESIGNED IN ACCORDANCE MTHASTME2112 L R49ERTOLO1114SP.E. Luis R. Lomas P.E. t4VKVODFORDROK7SVXLENC270M L434- M-O I? A a.mm FL No.: fi2514 c Florida Building Code Online https://www. Floridabui (ding.org/pr/pr_app_dtl.aspx?param=wG EVX... MIMI i Professional -Replation r SCIS Home I Login I User Registraton I Hot Topics ! Submt Surcharge 1 Stacs s Facts I PubU atom. I FSC staff i WIS Site Map j Links 1 Search I Flofida p r GO Product Approval USER: Pubic User r'? Tinri eci Product Aooroyal Men > Product or Aogl„ratlon Search > AppRaLn -wL > Application Dotal FL # FL1S279-RS Application Type Revision Code Version 2017 Application Status Approved Comments reapply 11/28/17 Archived Product Manufacturer Clopay Building Products Company Address/Phone/Email 8585 Duke Blvd. Mason, OH 45040 513)770-6062 mwesterriield@clopay.com Authorized Signature Scott Hamilton shamilton@clopay.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Certification Mark or Usting Certification Agency Intertek Testing Services NA, Inc. Validated By Gary Pfuehler Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year ANSI/DASMA 108 200S ANSI/DASMA 115 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM F330 2002 Equivalence of Product Standards Certified By Florida Ucensed Professional Engineer or Architect FL15279 RS Equ 20170809 - FBC- DASMA 109 equl"-df FL1S279 RS FqA% 20170809 - fBC - DASMAj15 equlv.Rdf I of 7 4/15/2018, 5:17 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVX... Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page ! a Method 1 Option A 08/10/2017 11/29/2017 12/05/2017 Model, Number or Name - 15279.1 001 W3-09 DSIE-1A171: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 62LG, 64G, SDP38, SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-20 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windbome debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.2 002 W3-09 DSIE-1A471 : GD1SP, GR1SP, GD1LP, GR1LP, AR1SP, AR1LP, ED1SP, ED1LP, 4132, 2132, 6132, SFC38, MFC38 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the Impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the Impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.3 ` 003 W3-09 DSIU 1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-20 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 0 0 Page 1/ 8 0 0 Description 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Single -Car (up to 9'0" wide) WINDCODE® W3 Garage Door Certification Agency Certificate FLl Z79 R5 C_SAS_L4LCgf w15C-proof_of contrAd_&nd.QCQgf gODSP-er-cioatl?df FL15279 RS C CAC W}-Ii,,tigg_Ins rte;k.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL352.Z9_R5_11 10165 S-Revl2. odf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Gallery/Artistry/Expressions: 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; Interior skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODE® W3 Garage Door Certification Agency Certificate f1152Z2 R5 C CAC Letter with proof of contract and proof gfjpi=U.gg,QQf FL)S279 R5 C CAC W3 Listing Intertek,01 Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FjI52Z9 "_U_103952-_&v-Q.LQdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Double -skin Insulated PUR (exterior skin 27 ga. min.; Interior skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODE® W3 Garage Door Certification Agency Certificate - F115279 RS C CAC Letter with flrgof of i:Q tMi; &nAoroof gf In5Qe_cUgn W FL15779 R5 C CAC W3 Listing Inttertek.flof Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 RS II 104175-Rgy01.p Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.4-^ 004 W3-16 DSIE-IA171: 20S0, 1-3/8" Double -skin Insulated EPS (ext 2051, 2053, 4050, 4051, 4053, 62, Interior skin 29 ga. min.) Double -Car 64, 65, 62G, 62LG, 64G, SDP38, WINDCODE(D W3 Garage Door SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 erlor skin 27 ga. min.; 9'2" to 16'0" wide) 2 of 7 4/ 15/2018, 5:17 PM Florida Building Code Online https://www. floridabu ilding.org/pr/pr_app_dtl.aspx?param=wGEVX... j Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Others The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the Impact resistant requirement for 4 windborne debris regions. The product without glazing DOES I comply with the impact resistant requirement for windborne I debris regions (ref 1609.1.4 MC). 15279.5 -- - 005 W3-16 DSIE-1A471: GD1SP, - GR1SP, GD1LP, GR1LP, AR1SP, ARILR ED1SP, ED1LP, 4132, 2132, 6132, SFC38, MFC38 Limits of Use --- • •---~----_-- -._-- - Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant, N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.6 - - 006 W3-16 DSIU-1A171:9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131,8133 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the Impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). i . Certification Agency Certificate f_115279 RS C CAC Letter with proof of contract and proof ofJnsgjgQD_rlpif FLIS279 RS C CAC W3 sting_I toertek.pdf Quality Assurance Contract Expiration Date OS/21/2028 Installation Instructions FLI5279 115 11 iQJ$29-Re t3 pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Gallery/Artistry/Expressions: 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double -Car (9'2" up to 16'0' wide) WINDCODE® W3 Garage Door Certification Agency Certificate FLt5279 RS CUC Letter w tF proof of corLtr_act and proof of inspgction.pdf FLIS279 R5 C CAC W3 Listing Inlertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 RS II 104028,RevOl.0f Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Double -skin Insulated PUR (exterior skin 27 ga min.; interior skin 27 ga. min.) Double -Car (9'2' to 16'0' wide) WINDCODEO W3 Garage Door Certification Agency Certificate 17Q RS G G C-I fitter with roofof contract and proof ofinspectlon.pdf FLIS279 RS C CAC W3 Listing I[1t9j ek pdf Quality Assurance Contract Expiration Date OS/21/2028 Installation Instructions FL1 279 RS U 104168-RevOf pd_f Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.7 148B4O07W3-16 PAN-2P153: 73, 1500, I Steel Pan (min. 25 ga.) Double -Car (9'2' to 16'0'wide) 75, 190, 84A, 94, 42, 48, 55, 420, WINDCODEQ W3 Garage Door SSS, 4RST, 6RST, 4RSF, 6RSF Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the Impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the Impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.8- - 008 W4-09 DSIE-1F171: 4300, 4301 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28 PSF/-29 PSF 1 Other: The OPTIONAL glazing available for this product Certification Agency Certificate EL$279 S C_L tter wi proof ofron r Pnd jamif OfJnsP_%ugn_.pd( FL}.52Z985__C_CAC_W 3_Li5ti gg_IOtertek,pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions L15 79 II 101$O8_Rgvj7„g_df Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2" Double -skin Insulated EPS (exterior skin 27 ga. min.; Interior skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCOOEQ W4 Garage Door Certification Agency Certificate FLI5279 RSCC_Letterwith proof of cgrltr ct_and-proof o i spect, ion ilf FLIS279 R5 QC W4 Listing InAi+rtek.pQ Quality Assurance Contract Expiration Date 05/21/2028 3 of 7 4/15/2018, 5:17 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_otl.aspx?param=wG EVX... meets the wind load requirements of the budding code but DOES NOT meet the impact resistant requirement for I windborne debris regions. The product without glazing DOES I comply with the impact resistant requirement for windborne I debris regions (ref 1609.1.4 FBC). i 115279.9 1009 W4-09 DSIE-1F471: GD2SP, i GR2SP, GD2LP, GR2LP, AR2SP, AMP, ED2SP, ED2LP, 4302, HOGC, 6202, SFC68, MFC68 _- Limits of Use Approved for use In HVHZ: No Approved for use outside HVH2: Yes Impact Resistant: No Design Pressure: +28 PSF/-29 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. 15279.10 010 W4-09 DSIU-1F171: 9200, 9201, 9203, HDP20, HDPF20, HDPL20, 7200, 7201, 7203, 8200, 8201, 8203 Installation Instructions I'L15279 R5 It 1Q1($_L-B-Rg-v1j_,P0f Verified By: Intertek "lesting Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Gallery/AriLlstry/Expressions: 2" Double -skin Insulated EPS exterior skin 27 ga. min.; interior skin 27 ga. min.) Single - Car (up to 9'0" wide) WINDCOOEO W4 Garage Door Certification Agency Certificate - - F11-5279-95 C--CAr-Lgtt_ r w th orooj of Cgntract and_prooff of inspe tcion.ndf E615372f35-C CA(;-N/3 19t1ng_IrlSertek.P_df Quality Assurance Contract Expiration Date O5/21/2028 Installation Instructions h 1-7,7y R}_I1 Q 96y-B-Rev02.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by independent Third Party: Double -skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODE® W4 Garage Door Limits of Use - Certification Agency Certificate Approved for use in HVH2: No f_LI,527295C CAG 4etter with proof of contract and prgpf Approved for use outside HVH2: Yes off inSgection.pQf Impact Resistant: N/A FL15279 R5 C CAC W4 I- Sting I tertek.lf Design Pressure: +28 PSF/-29 PSF Quality Assurance Contract Expiration Date I Other: The OPTIONAL glazing available for this product 05/21/2028 f meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for EW5.2- 9 R$ II_J_04183-&v l.pff i windbome debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. i comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279. 11 011 W4-09 DSIUO-1K479: Canyon Double Skin Insulated PUR (exterior skin 27 ga. min.; Ridge/ Brookstone Interior skin 27ga. min.) with Overlay Single -Car (up to 9'0' wide) WINDCODE® W4 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVH2: No FL15379 5-C CAC Leer wlttLpLQPLQf C4IlVdCtAn0_i2rs f Approved for use outside HVH2: Yes Qf_ i1Sg2St1MPdf Impact Resistant: N/A FL15279-RS-C-CAC W9-Usting_Intertek,Wf Design Pressure: +28 PSF/-29 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product OS/21/2028 meets the wind load requirements of the building code but I Installation Instructions DOES NOT meet the Impact resistant requirement for i EL15279 R5 II 104456-RevOl.adf I windbomedebrisregions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the Impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279. 12 012 W4-09 PAN-21`151: 73, 1500, 7S, 190, 84A, 94, 76, 42, 48, 55, 428, 488, 555, 4RST, 611ST, 4RSF, 6RSF, 211ST, GDSS, GOSSV, GRSS, GRSSV, ARSS, ARSSV, EDSS, EDSSV Limits of Use - Approved for use in HVH2: No Approved for use outside HVH2: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the Impact resistant requirement for windborne debris regions. Steel Pan (min. 2S ga.) Single -Car (up to 9'0" wide) WINOCODE® W4 Garage Door Certification Agency Certificate FL15279 115 C CAC Letter with proof of contract and proof of inspe ction.p f F1. 15279 95 C CAC W4 Lig i ig Int9d9k P-Of Quality Assurance Contract Expiration Date O5/ 21/2028 Installation Instructions FLI5Z? 9 R5_1 00159_B_6evl6,pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 4 of 7 4/15/2018, 5:17 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVX... IS279.13 i Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this produc meets the wind load requirements of the building code DOES NO•r meet the Impact resistant requirement for windborne debris regions. 1013 W4-09 PAN-21`441: G4S, GS4, G4L, GL4, GD4S, GD4L, GR4S, GR4L, G4SV, GS4V, G4LV, GL4V, GD4SV, GD4LV, GR4SV, GR4LV, E4S, E4L, ED4S, ED4L, E4SV, E4LV, 1 ED4SV, ED4LV, SS4, SL4, AR4S, yAR4L, SS4V, SL4V, AR4SV, AR4LV- t but 15279.14 - 014 W4-09 SPO-2F449: Harbor, Stone Manor Grand Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-32 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the Impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for wlndborne debris regions (ref 1609.1.4 FBC). Gal lery/Artistry/Expresslons:-Steel Pan (min. 24 ga.) Single - Car (up to 9'0" wide) WINDCODEQ W4 Garage Door Certification Agency Certificate - ^- E - 527.9 R5 C CAC Letlef witlLRCgof of contract sand proof of inspectton,pdf EW_279 RS C CA_C_W4 Ligin Ignt ,Pk_.p_d( Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions EL15279-R5_I I-103.486_B_t3ev_08.adf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Steel Pan (min. 24 ga.) with Overlay Single -Car (up to 1 9'0_wide) WINDCODE® W4 Garage Door -_-- _ - - Certification Agency Certificate FLIS272 R$ CAC Letter with proof of contr t and proof of Inspectlon.od FLIS27985 C CAC W4 Listing Intertek,pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 RS II 103549-9ev-Orl.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279AS 01S W4-16 DSIE-1F171: 4300, 12" Double -skin Insulated EPS (exterior skin 27 ga. min.; 4301, 4310, 4400, 4401, HDG, Interior skin 27 ga. min.) Double -Car (97' to 16'0" wide) HDGL, HDGF, 66, 66G, 67, 67G, 68, WINDCODEO W4 Garage Door Ifl SP200, SF200, SE200, 6200, 6201, 6203 Ai-p- its of Use _ _ - - } Certification Agency Certificate proved for use in HVHZ: No FuS279 RS_C CAC Letter with proof of contract aQctp ogf proved for use outside HVHZ: Yes plot inspection Impact Resistant: No FL15279 RS C CAC W4 Llslina Intertek.pdf Design Pressure: +25.5 PSF/-25.5 PSF Quality Assurance Contract Expiration Date I Other: The standard glazing available for this product 05/21/2026 i meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the Impact resistant requirement for FLIS279 RS tt 101481-B-Rev13.pdf windborne debris regions. Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.16 016 W4-16 DSIE-IF471: GD2SP, Gallery/Artistry/Expressions: 2" Double -skin Insulated EPS GR2SP, GD2LP, GR2LP, AR2SP, (exterior skin 27 ga. min.; Interior skin 27 ga. min.) Double- AR2LP, ED2SP, ED2LP, 4302, HDGC, Car (9'2" up to 16'0" wide) WINDCODES W4 Garage Door 6202, SFC68, MFC68 Limits of Use Certification Agency Certificate Approved for use In HVHZ: No E11.15279 RS._C_CI C Letter with of of contract aid prop( Approved for use outside HVHZ: Yes of inspectlon.pdf Impact Resistant: No FL15279_RS C CAC W4 Listing Intgrlek.pdf Design Pressure: +25.5 PSF/-25.5 PSF ( Quality Assurance Contract Expiration Date Other: The standard glazing available for this product 1 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the Impact resistant requirement for FL1,527)1 RSJt 104P2.9_0-Rev03.pdf windborne debris regions. Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.17 017 W4-16 DSIEO-IF479, Double Skin Insulated EPS (exterior skin 27 ga. min.; Interior Coachman/Settlers/Affir skin 27ga. min.) with Overlay Double -Car (up to 16'0" wide) WINDCODEp W4 Garage 5 of 7 4/15/2018, 5:17 PM Florida Building Code Online https:/hvww. fl oridabu ilding.org/pr/pr_app_dt l.aspx?parain=wGEVX... Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF I Othert The OPTIONAL glazing available for this product meets the wind load requirements of the building code but II DOES NOT meet the Impact resistant requirement for i windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.18 - r920HDPL20, 4-16 DSIU-1F171: 9200, 1, 9203, HDP20, HDPF 7200, 7201, 7203, 8200, 8201, 8203 Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +21.1 PSF/-25.5 PSF Other. The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windbome debris regions. The product without glazing DOES comply with the Impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate f:j_15179_R5_C CAC Letter with proof of contract and proof of Inspection.pr4f FL15279 95 C CAC W- 1 it ng Intertel &df Quality Assurance Contract Expiration Date OS/21/2028 Installation Instructions FI157•9—II 10 046-Rev 7.pQf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Double - skin Insulated PUR (exterior skin 27 ga. min.; — Interior skin 27 ga. min.) Double -Car (9'2" to 16'0" wide) WINDCODE® W4 Garage Door Certification Agency Certificate- f 7r R5 C CAC I.Pdtef w1t11_proof p(_Gont[aS an _Drool of Inspectlon_Qdf FLI$_ 2Zy_RS C (ate W4 LI,ting_lntertek.pof Quality Assurance Contract Expiration Date 05/ 21/2028 Installation Instructions FL15279 R5 Il 104169-t3gy01 pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279. 19 019 W4-16 DSIUO-LK479: Canyon Double Skin Insulated PUR (exterior skin 27 ga. min.; Ridge/ Brookstone interior skin 27ga. min.) with Overlay Double -Car (9'2" to 16' 0" wide) WINDCODE@ W4 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL __ RS C CAC Letter with omof of contract and proof Approved for use outside HVHZ: Yes I of Inspection.pdf Impact Resistant: N/A FL15279 R5 C CAC W4 Listing lntertek.Ddf Design Pressure: +25.5 PSF/-25.5 PSF I Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product j 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the Impact resistant requirement for I FL1S279 RS It 3044S7-Rev02.pdf windbome debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windbome Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279. 20 020 W4-16 PAN-21`153: 73, 1500, 7S, 190, 84A, 94, 42, 48, 55, 4RST, 6RST, 4RSF, 6RSF, GDSS, GOSSV, GRSS, GRSSV, ARSS, ARSSV, EDSS, ED5SV Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24 PSF/-24.5 PSF I Other. The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windbome debris regions. Go to Page 0 Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0' wide) WINOCODE® W4 Garage Door Certification Agency Certificate Lgttc wJLl`alQprocif of insoection. odf W52Z9_&5C CAC Yva Llsting-1Menek.Pdf Quality Assurance Contract Expiration Date 05/21/ 2028 Installation Instructions f1152799 115JL 3017AL-B_Rev-15_-pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: tladt Ne= t 0 0 Page 1 / 8 0.m The Slate off rida ban AA/EEO employer. t-Apybgt,t3ll4L•3111 S%a 4_"F rUL :: PrrlydCY Statement :: ArcossIhKV statement :: Refund Statement Under Florida law, email addresses are public records. If you do rat wart your e-mad address released in response to a pubat-records request, do not send electronic 6 of 7 4/15/2018, 5:17 PM Florida Building Code Online littps:/hvww.floridabuilding.org/pr/pr_app_dti.aspx?paratn=wGEVX... mall to this entity, instead, contact the omce by phone or by traditional mall. If you have any questions, please contact 650.497.139S. *pursuant to Section 4S5.27S(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 45S, F.S. must provide the Department with an emal address If they have one. The emals provided may be used for official communication with the licensee. However emal addresses are public record. If you do riot wish to supply a personal address, please provide the Department with an emal address which con be made available to the public. To determine if you are a licensee under Chapter ASS, FS., p',ease clkk he10_ Product Approval Accepts: Ili BE Credit Card Sale 7 of 7 4/15/2018, 5:17 PM s•iMM wx tmam Nme 10 fA 10 CA w: a.WATAiYLTMI' ate, am 1133". H.nv AAIITM as1 Am. LgO Law CM Can, Can, r7. 11 M a rl. n e 0 0 aai Hr 1 V.Asw IMAM Ham -ma SVGA %Aa.IQ Maw ImIlLDGL= ow rem+na . AMO mom"m am K mars faWN M e. n... Ir e• nlar.ur ..rt IeaQ.Y IOQY. SEE SHEET TWO FOR IMPACT RESISTANT CONSTRUCTION DETAIL "A' AND STANDARD CONSTRUCT DETAIL "B"; TRACK AND JAMB DETAILS. SHEET I OF 2 OTRICW. GLAZDNO MAY BE STANDARD OR OIPACT HES MANT GLAZING. SEE SECTION B-B MR DETAILS. He.mW mn ate& m an MAIL STANDARD SME IS 42-1/2-.16-. IMPACT oeia[...iM.au WoeMam — RESISTANT GLAZING IISS, 2 6-.14-1/B ZA I& III III A nIIIIIIkk a WRONL VAM WO I= Pomm o r Iart wa.M ri O O MMMN. tY i atOl SHIP LAP JOINTS. - m Ii if DENSITY POLYSTYRENE FOAM NSIMRON 1- 5/16- THICK WITH MNTL IIAWCELL BACKER QNSULATED MODELS ONLY) 25 CA. ADN. CALV. STEEL SKIN WITH A BAKED -OH PRIMER. AND A BAKED -ON POLYESTER TOP COAT APPLIED TO BOTH SOB OF STEEL SHIN. W m iMa n Lam m .°momao si noelYOO Rat M e<.IIOM1oN ..on0 anal P® i amp aAC Koamrso4.rsNm ..wNNIrM.Hs >sR aw . 4r.wm1+ w sraAauurAs aWiao Ya m i W m Ae a. am wwM a d n v Ir Clepay ATE, /3/97 a1T. 1/1/ B7 IngProducts *UmASLsOK-0—Ha4B`. iZ '"w" "' JAc DOn (W) 770-4600 Dual NY. C"" C.P..6. a NKI. ail.4 L(WW nA?AIL VM"- MR SWTION A — A (SIDE %NM J- TALL U—BAR MI CJL CALV- STM MIN. TEPID STRENGTH: 50 KS 2* THICK 4: ,-1 Hj T 12 G CALV. STEEL TOP ROLLER BRACKET. EACH BRACKET ATTACHED W/( 4) 4 - SWEET METAL 14 CA CALV. ROLLER HINGE.. EACH HINGE FASTENED TO END SLIMES WITH (4) 114."- SEET METAL SCREWS AND (4) 1/ 415/4- SELF TAPPING SCREWS. SEE MEW 'B a\ TALL a 20 GL CAM STEEL U-BARS IN A 2-1-2-1 PATTERN ( I.E. TWO U-BARS ON BOTTOM SECTION. ONE U-w ON NEXT a SECTION. ETC.). EACH U-SAR ATTACHED WITH (2) 1/4'a3/4- SELF TAPPING SCREWS PER STILE LOCATION. 15 GA- CALV. STEEL. BOTTOM BRACKET. ATTACHED WITH (2) /14.5/B- SHEET METAL SCREWS. ALLIMM EXTRUSION t MI11'L WEATHERMCP DESIGN LOADS: +24.0 PSF t - 245 PSF TEST LOADS: -36.0 PSF It - 37.0 PSF VD AIa MATING NAIL man sm W 4 16'0'w K 16'0' H rs00"Inm CLASSIC AND CH RP STEEL PAN DOUBLE -CAR. 18'W +24/-24. 5 PSF B NUNa<w 101711 1 BC qmAss MUSH Arm Dow .Con ®1 4ma • S Maw wlE TIOI Amt 24 CA !a u a CAa CAas aA /_IK m awn SHEET 2 OF 2 ,s _ sn alVeAR la)aar OR sRar es pa.AA aM. M - l7. 17 o.a I" sOaQ IAo t e01.rlfO.r Our 11a1 !O) 1Y /110 10: A RM IK& A.7T, h Aao N .ar • Mp ma SIKA IloaofaaR Ylm 00 a0I OMOIO 1010 ML.m IM-1 a fsf frsl wn ^.Y flare .oseuuia vmrm'I'm rs en a nAmr caf .CLLv= Colt ram irul IaA M[IIl11• 1%.1J• UP= XMM m Ir Comm OAe A r mmaD e or 7YOYQ •CIS' .A® rKl Como lb.a sIf>y. /' m "Om WL1 .Col w Cop Dom mmYOOm wf R apaaeflM OIA Me mptm m PIMMIX . P.M Amat a w in CA an ICIaIRIo pArAOC `Alva OD Ae M a WY 4 iD.1 . 001 P OMa.l a7a ILM A Ym OaaTOA/ r m¢aaraOwAle riK MmaAaa IA7mO0 v AIOs Aa77• AL rAIM94M w iaf• f tasv a. ar anAen 001 Ira? SIM MUM w Ow .61Oua (W A.0 7.. ICAOa ..p Y ao Nt 0 f 14q P 4 car. a01 MIDI .pe Groat h61Om To M J4o/ aml ore 9/Ir.1 1/Y E101 T o.a rvaae wa neaoo m tun ig1D4 (i,old 00 • 1=1.6,r am Aalr IMPACT RESISTANT ASSEMBLY DETAILS A. G Caa .pfa IOCL aA01 NMrcaromIMarAfmmmAmmomovAfnapmN) a )RAIx cowaAw" DRAWING 10171 1-A I7 G wv. t .aAa •I.pmA Ima I ..4/.R llf •eras Ij fGI Irl%R a f oi (1 DOESASM ENE DOOR oPEU/CND SECTION B-B (IMPACT-RFSISTANT GLAZING OPTION ram Ip• ow man DOB NM G OF THE ORWADRATINGOF ))OS DOOR. ma v O cmS!m ffp flm IWtll na a plll MMr tR cow OMM m°so AIlo. mme>ef 41 r la. ooAe rAo uaal Mvrm ON sm we U0) TOP MKIQT 0pi.r-. Ieov. po.ml rl..a ao rnoo amaze.[ / s /wR `M Om01 R 11E OROO.0 SAIONMI OOWO PMt t nr 17 4 f+la arm I4C i40iQ. DTOO NOi1Q01RK O at .A= Zap ColfK ptoM . fAa IASI00 Mom Ow tall) ISnLcnm pl :l o. I p.ap ..IPD aoa Is Ira {Om w an.•.1- .00o uo swm Omm foartt acttm m .o. rr tt.vAa Cold a TRACK 6 np uwer.. ombp ramot rafaacr Aorol PTOO W mum am B r auc mm nps le® a In. IA IR . ri• nw wo ret seava w mum MOOMM .ao' 1. FIVAiCM STAIII GONS1RlM.IION: m. f-I/I117 4 Aa•. arm Cola aAAD= OlC oop6 pA011i', mOIO .tM MIO ArACPaCRO" OAOC AM (A) Copt OVO017 r01 UL a/ apva wenaR-YOIoIA mmove m A a mm Am QMCC a Q U Aa SM&M. N APPOM = 1W,C r ACCMW= aYll IIL L aaaC OoplA7sOaa .aOaAO M WOYMC[ mM a0 w.7at Y017 1K a0 LAMafplRlma! R ra rlAaffA YOC cow no dlOvlAiall •alaM6 Cma as Y®M Mfi-IEwfAMI RmNOOR! Oa. CMMO1 la IR/oCl am tll ! Im 3 00® 0. 0 r pLL STANDARD ASSEMBLY DETAILS ORYWINO 1 O t 77 / -B t7 G Nla am rM *AS W1 Is 4rAfIO .saA rr .IM . LAO SECTION ( NON - IMPACT RMSTANT OWING OPfI0N1B-B (NON -IMPACT RMSTANT GLAZING OPfIONI (A "X VIM _ fr Iri. a° ai nooiasl C ' n. Mao Agra rm my mm pt mme alert Af f- V7'.0 G e+u s q nua rAoar. 1IM apt Mart Aac a rAleOap 1w 10 W ma Haan rw !ma Q. m /r ArIIC!-I NC IRrt fk RIARA mm 14 _ Iv m Ir MOI Ap lel m Osro lP iM0[ 1 olAaA. L:^. J: tCLa"` f wa 000a ova yy4 1 arm p'pMu wr pyA• vAv Ito suet D Oaam LM Comm COMwelt6 m MOWocpI& v amIT DESIGNLOAM + 24. 0 PSF t -24.5 PSF onaAa IM aea a t aaar I!R na . L TEST LOADS: +78. 0 PSF t -37.0 PSF uoarc Acme andw. rus " aPmt a fuala 0 AI.IO. e m I.Lfat M AO>4a11d tAl lJRC WmaD aATDG Ml OM UM m` Clopay ATEPAN- 2F153 ra oat opvl wa fsoalr aapllm M elrlrMe W 416•0•W a 16.0-H Aa nm .sw Ims ra AO IAO amam011i • a ra 11A 1aA auuate efaa a .tlOawaAa ) /3/97 MCRPTM CLASSIC AND CH RP STEEL PAN tA.IOC aaaa MUST ALQ at tvr el amlrtl amro 'r i . RRa O oun aemle pcpma swat sl pp P u* Nw• uarM m DOuBIE-CAR. ) BYi +24/-24.3 PSF P, .a„ Building Products MAsaN. off 4w4o ,)Ac Company (313) »D-4e00 wAwe< la.lma lac Dwso 27ro 17 -- - - M— B )o»Ii b Florida Building Code Online https://www. floridabu ilding.org/pr/pr_,ipp_dtl.aspx?param=wG E V X... III ness • - • rca SCIS Home ; Log In I user RepStratbn I Mot. Topics ; submt Surcharge ( Stats a Facts I publications I F8C Staff I acts Site Map I Links I search I ridUS s r odud Approval USER: Pubfr< User Product Anruoval Menu > PredUa or Apphretlon jparcn > dpoNca[lo^•yyt > ADprralbn OataU FL # FL17499- R3 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/ Email Authorized Signature Technical Representative Address/Phone/ Email Quality Assurance Representative Address/Phone/ Emall Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method MI Windows and Doors 650 West Mafket Street Gratz, PA 17030 717) 365- 3300 Ext2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Windows Single Hung Certification Mark or Listing American Architectural Manufacturers Association Steven M. Urich, PE Validation Checklist - Hardcopy Received Standard AAMA 506 AAMA/WDMA/ CSA 101/I.S.2/A440 AAMA/WDMA/ CSA 101/1.S.2/A440 Method 1 Option A Year 2011 2008 2011 1 of 4 4/13/2018, 7:05 AM Florida Building Code Online https://www.floridabuilding.org/pr/pi_app_dti.aspx?param=wG EVX... Date Submitted Date Validated Date Pending FBC Approval Date Approved summary of Products FL Qt _ Model, Number or Name 117499.1 185 SH Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-55 Other: R-PG55*, Missile Level D, Wind bedded in Pecora 896 sealant. 17499.2 1 185 SH Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: R-PG60 117499.3 _- 1 Limits of Use 185 SH Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 i Other: R-PG60* i I 17499.4 — 1185 SH — Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-67 Other: R-PG60*--^---- 01/15/2018 01/15/2018 01/21/2018 Zone 3. Glass to be Description 36x84 Fln/Flange Frame IG/SG Impact Single Hung Certification Agency Certificate FL17499 R3 C_rgC MI Windows - 185 SH (Fin} I r pact 4),pdf fL17499 R3 C CAC_{,1I Win ov_ys - ]B(Fin) impact (5) Don—e.p& f FL17499 R3 CCAC_Ml Windows -,1885 SM fFlange Impact 3).pdf FL17499 R3 CCACTI Windows - 185 SH (FlCngel Impact 4),pdf Quality Assurance Contract Expiration Date 10/17/2018 Installation Instructions FL17499 R3 II OS_Q2545B.pdf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL 1749_R3-AE_513321 8-3_pdf Created by Independent Third Party: Yes 5202 Fin/Flange Frame IG/SG Single Hung Laminated Glass Certification Agency Certificate- 1`117499 R3 C CAC APC(,13361 l}726.01_109-M17_ go 185 SH FLG wa ver),pdf fL17499 R3 C_CA C MI Windows_}85 SH (EKI)-(1 LD.Of Ii F t 499 R3 C CAC MI Wjndows - 185 SH (Fin) (12),o I F17,7499 R_S-CgC MI Windows - 185 511_(tJange) I .=--Pdf Quality Assurance Contract Expiration Date 10/08/2018 Installation Instructions FL17499 R3 It 04-02541)B,pdf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports EL1749_9 R3 AE $133278-4.pdf I Created by Independent Third Party: Yes — 36x84 Fln/Flange Frame IG/SG Single Hung Laminated Glass Certification Agency Certificate FL17499 R3 G CAC APC(13303)E1729.Q1-109.-47_U_18$ S_(FLG waiverl.pdf FL77499 R3_C CAC I Windows 185 SH fflp _(t3),pdf r7499 R3 C CAC MI Windows 185 SH FL17499 R3 C CAC MI Windows t85 5-H(Flange) 11}, pdf Quality Assurance Contract Expiration Date 10/ 17/2018 Installation Instructions i FL17499 R3 II 08_Q2550B,pdf VerifiedBy: Luis R Lomas PE-62S14 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513328E-5.pdf Created by Independent Third Party: Yes 3601 Fin, Finiess, Flange Frame IG Single Hung Certification Agency Certificate FL17499 R)C C8 AE( H0j§jM.-1U9-47-R0-A85 5j Q4Z522)-- P9f Quality Assurance Contract Expiration Date 04/ 25/2022 Installation Instructions - 2 of 4 4/ 13/2018, 7:05 AM Florida Building Code Online https://www.floridabuildiiig.org/pr/pr app dtl.aspx?param=wGEVX... 17499.5 — 1185 SH i- Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-55 Other: R-PG55, Missile Level D, Wind Zone 3. Glass to be bedded in Pecora 896 sealant. 17499.6 _ 185 SH Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: R-PG60 1 _ 17499.7 - fTriple SH Limits of Use - Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other. R-PG50• FL17492 R3 If 08-03163,,p_df IE Verified By: Luis R. Lomas, PE PE-62514 Created by independent Third Party: Yes Evaluation Reports FL17499 R3 A 514 pelf Created by Independent Third Party: Yes 52x72 Fin/Flange Frame IG/SG Impact Single Hung Certification Agency Certificate FL17499 R3 C CAC MI Windows - 185 5(_I_(EjflLImpactapaff FL17499 R3 C CAC MI Windows - 16.5 SH (EM) ImpaC1 L31• 9-0-f E417499 g3 c CAC MI Win ws - 185 5AjFI nog) Imoact zlpdf FL17499- K-C-CAC 01 Windows - lg S i nge) L -&- S). p.4fQuality Assurance Contract Expiration Date 10/ 10/2018 Installation Instructions FL17499 R— II Og-02544B:,pQf Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513320E-1.gdf Created by Independent Third Party: Yes 52x84 Fin/Flange Frame IG/SG Single Hung Certification Agency Certificate F117g99- R3 C CAC APCQ 3.62)E172 ..Qt:AQq 7-g0_j65 H( ELSzWeaiveTlS-Air 1-BA 5% 1-8X84 R6Q{}QQj1,Rdf FL17499 R3 CCAC MIW,Indowc - QS H_(pjn}_(,p f EL17422 6k3 C CAC MI_WjRdQWS_3fl5 SH fFln)_(2).g!j( EL1. Z429 R3_C CAC MI Wy!dgws_z 1$5 511_(FlAgg W).Nf Quality Assurance Contract Expiration Date 10/ 09/2018 Installation Instructions ELdZ422_ B3! I @_4359.5 2.pd_fVerified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: Yes 111x72 Fin Frame IG/SG Single Hung 110x72 Flange Frame IG/ SG Single Hung Certification Agency Certificate V 171- 17499 R C CAC MI WiOdQ y F_ i-17499 R3 C CAC M( Wind Ws - 185 5 I TFIp,J jFL)n4Lgdf F 7499-R3 r CAC-MLWiOQows--1Q5:SJF TH121t Flan 3). Qdf FL1749% R3_C_CAC__Mi Wlrtd4W5_:_j@5 SH Tnpsl rjgel 41. Odf Quality Assurance Contract Expiration Date 10/ 20/2018 Installation Instructions ELUA."- . 3-I1_R6L%Q2599@.Riif Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports ELIZ- E 513324B-6odt Created by Independent Third Party: Yes 17499. 8 185 Twin SH i 106x72 Fin Frame IG/SG Single Hung 10502 Flange Frame G/ SG Single Hung Limits of Use - Certification Agency Certificate Approved for use in HVHZ: No fL17493 R3 C CAC MI Windows - 185 SH'r1Mn (Fin) Approved for use outside HVHZ: Yes Uhaw Impact Resistant: No F13749 it3 CAC Ml indowy__i85 SH llaln_(tin) Design Pressure: +45/-45 WIPAr Other: R-PG45 EL17499 R3 C Cq_MI Windows - 185 SFi Twin llang0 3)- PAf 3 of 4/13/2018, 7:05 AM Florida Building Code Online 1)ttps://www.Floridabuilding.org/pr/pr app_dtl.aspx?paramwGf VX... f".74 9 _S_4,4C MI Windows - W SHTwin (Flangr) l (4)_pdf Quality Assurance Contract Expiration Date 10/20/2018 Installation Instructions fL1.7499 R3 LI 09.025478.7.pdf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FLJ2j22_R31tE 513323B-7 Ddf Created by Independent Third Party: Yes Contact us :: 2fi01 Blair Stone Read. T>tlana se FL 32399 Phone: 8So•48]_}821 The State of Florida Is an AA/EE3 employer Coovdoht 2007.2013 State_qLEbrI& :: EEhW!Y 5tatemem :: Acessl6Aty Sutement :: ftefuna 5utemen Under Florida law, email addresses are public records. Ir you do not want your a-mal address released In response to a pudic -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by tradtlonal mat ff you have arrr questions, please contact 850.487.1395. 'Pursuant to Section 455.27S(1), Florida Statutes, effective October L. 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an emal address C they have one. The emats provided may be used for official communication with the acensee. However emall addresses are public record. 9 you do not wish to supply a personal address, please provide the Department with an emal address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click (le[L. Product Approval Accepts: Rig R M t Credit Card Safe 4 of 4/13/20t8, 7:05 AM NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REOUIREMENTS OF THE FLORIDA BUILDING CODE. 2 WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED 70 PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2- WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. S. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR 01HER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. S. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REOuIRED 41 EACH ANCHOR LOGITKIN WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE i/4 9. SHIMS SHALL BE LOCATED. APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS 10. WIND LOAD DURATION FACTOR Ce=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL- EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09. SEF SHEET 11 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE IS WOOD SCREWS WITH SUFFCIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE LOCATE ANChORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. RCVISRINS USCRP110v DATE APPRJY'D REVISED ANCHOR SPACING & CHARTS 1 07/11/18 RL REUSED GLASS 10/02/17 1 R.L. 15 FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WIIH SUFFICIENT LENGTh TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WRrl 2 1/2" MINIMUM EDGE DISTANCE LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17.FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT. 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSiRUCHONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B CONCRETE: MINIMUM COMPRESSAIE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2.ODOPSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (0487 FY=33:cS1/FU=52KSI OR ALUMINUM 6063—TS FU-30KSI 048" THICK MINIMUM iASLE OF CONTENTS SHEET NO. DESCRIPTION 1 NOTES 2 — 3 ELEVATIONS 4 — 10 INSTALLATION DETAILS 11 1COMPONE147S SIGNED: 1211412017 MI WIN650DO DEDOORDOORS, LLC IIL04f,/,, SS MA SIR GRATZ. PA 17030-0370 NGEN,F 9 1 0 5 * - SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT OENOTESo , TAT OF cIORICr• i iSS/ONA11 1C`\. oaun• ows No. eEv N.G 08--00E2r549 B BATENTS 12/29/14 1 OF 11 Luis R. Lomas P.E. FL No.: 62514 L ROBERTO LO""AL 14.V WOODPoAD RD LEVASVRIE NG 27= 434-w.om dwAwktfiwM=M 2" MAx I 1 16' o C. 72' — AAx U+ME TIGHT 52- MAX FRAME WIDTH 16 MAX O.C. --{ i OMAX Ay n X 52' MAX FRAME WIDTH 2' MAX 2" MAX 16' MAX O.C. 2" MAX 2' ' 16" I 0 IMAX — / D.C. 72' T— Mnx FRAME HEIGKT rj 4 X i 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW DESIGNER EXTERIOR NEW FLANGE 6 FINLESS INSTALLATION FLANGE 6 FINLESS INSTALLATION SEE CHART /1 FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART ei FOR SMALLER UNITS REQUIRED ANCHORS DESIGN PRESSURE RATING IMPACT RATING t60.0PSF NONE NOTES: 1 MAXIMUM SASH SIZE: 51" X 36". 2. MAXIMUM SASH D L.O.. 47 5/8" X 32 1 /2' 3. MAXIMUM FIXED 0 L.O.: 49 3/8' X 32 1/2". SWEEP LOG AND TACKLE I REr1iIDN5 REV DESCRiTiN:+ GiE APPRDK_D A REVISED ANCHOR SPACING Y CHARTS 1 07/11/16 1 R.L. B REVISED GLASS 1 10/02/17 IRA CHART 191 Number of anchor locations required Frame Frame Width In Height 1&00 2A00 30.00 3400 42.00 4&00 52.00 in) Head Jamb HeadM513 Jamb Head Jamb Head Jamb Head Jamb Head Jamb 24.00 2 3 3 3 3 3 4 3 4 3 4 3 30.00 2 3 3 3 3 3 4 3 4 3 4 3 36.00 2 3 3 3 3 3 4 3 4 3 4 3 42.00 2 4 3 4 3 4 4 4 4 4 a q 1000 2 4 3 4 3 4 4 4 4 q 4 4 54.00 2 5 3 5 3 5 4 5 4 5 4 5 00.00 2 5 3 5 3 5 4 5 4 5 4 5 66.00 2 5 3 5 3 5 3 5 4 5 4 5 4 5 7200 2 6 1 3 1 6 1 3 1 6 1 3 1 6 4 6 1 4 1 6 14 6 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ. PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52' X 72" NON -IMPACT FLANGE k FINLESS ELEVATIONS N.G. 1 08-02549 xrar NTS oAr 12/29/14 sr¢c12 OF 11 L ROBERTO LQ'AAS P.E. UN KOODFORD RD LE1019VILLE NC 27M 430-M- 09 n4WrASp kmepecwn SIGNED. 1211412077 IR I LOW/,, i G E NSFqLp a} 0„61251 •• o' STTAttTttE OF OE ei Luis R. Lomas P.E. FL No.: 62514 52" MAX FRAME WIDTH 2" MAX 10' MAX O.C. 10' MAX O.C. 0 72" 1 MAX FRAME 2" MAX 2" MAX 52" MAX FRAME WIDTH F 10" MAX O.C. 2" I 10' MAX O.C. MAX FRAME IIHEIGHT II HEIGHT y 4 Q it KvIslows RLV DCSCMPMN CAI. MPROtTA A REVISED ANCHOR SPACING h CHARTS 07/11/i6 R.L. 1AX 8 REVISED GLASS 10/02/17 R.L. CHART #12 Number of anchor locations required Frame Frame Width In Height pn) 18.00 H 6 S Jamb 24.00 HAS Jamb 30.00 HAS Jamb 36.00 HAS Jamb 42.00 HAS Jamb 48.00 HAS Jamb S2.00 HAS Jamb 24.00 3 3 3 3 4 3 5 3 5 3 6 3 6 3 201.00 3 4 3 4 4 4 5 4 5 4 6 4 B 4 36.00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 410D 3 5 3 5 4 5 5 5 5 5 6 5 6 5 48.00 3 6 3 6 4 6 5 6 5 6 6 6 6 6 54.00 3 6 3 6 4 6 5 6 5 6 6 6 6 6 60.00 3 7 3 1 7 1 4 7 5 1 7 r 5 7 6 7 6 7 66.00 1 3 1 8 1 3 1 8 4 1 6 1 5 1 8 1 5 1 8 1 6 8 6 8 T2.00 3 8 3 8 4 8 5 8 5 8 6 8 6 8 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW EXTERIOR VIEW FW IMSTALLA770M FIN INSTALLAT)ON SEE CHART 02 FOR SMALLER UNITS REOUIRED ANCHORS SEE CHART 02 FOR SMALLER UNITS REOUIRED ANCHORS DESIGN PRESSURE RATING IMPACT RATING t60.OPSF NONE INOTES: I. MAXIMUM SASH SIZE: 51" X 35 2. MAXIMUM SASH D.L.D.: 47 5/8" X 32 1/2'. 3. MAXIMUM FixED D.L.O.: 49 3/B' X 32 1/2'. N.1(2) METAL SWEEP LOCK AT 6• FROM EACH END INTERIOR MEETING RAIL I SIGNED: 12/14/2017 MI WINDOWS AND LLC TR650WESTMARKETSTREETET GRATZ. PA 17030-0370 GEH,r 9dh'ii y b„625 *= SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" x 72" NON -IMPACT FIN ELEVATIONS p • STATE OF i'°••'(ORID" DnxwN: arc No. nn N.G. 08-02549 B SS • IOIIIAl11l\\ Luis R. Lomos P.E. FL No.: 62514 sr LE NTS D"rz 12/29/14 S'ER3 OF 11 L RDaERTCLOMASP.E In2µt10DfORDRDLEWISVILLE.NC27W3 43f W41 0a Aomesp*lwkame.om PEVISaNS 1/2" MIN REV CESCR7PRON DATE APPR(*q EDGE DISTANCE REVISED ANf.YAR SPACING d[ CI'1.RT5 0/Ili/1E R.L WOOD FRAMING Wl/4' D REVISED GLASS 10/02/17 R.L. OR 2X BUCK BY OTHERS1 1/4" MIV. MENT BACKER ROD APPROVEDMAX' SEALANT PACE II III #10 WOOD SCREW 1 MIN. EMBEDMENT 1_ 1/2' INTERIOR MIN EDGE DISTANCE As I 10 WOOD 10 SCREW WOOD FRAMING OR 2X BUCK EXTERIOR I BY OTHERS BACKER ROD APPROVED SEALANT MOOD FRAMING OR 2X BUCK BY OiHERS SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 4- MAX. SHIM SPACE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUG( INSTALLATION NOTES: I. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED INACCORDANCE WITH AS FM E2112 1/4' MAX. SHIM SPACE INTERIOR BACKER ROD APPROVED EXTERIOR SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION SIGNED: 1211412017 MI WINDOWS D LLC T650WESTMARKETSTREET GRATZ, PA 17030-0370 GEN, U+ 10y,.8 i5 * - SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON -IMPACT t+O FLANGE INSTALLATION DETAILS DO,• $STATEEEES Of o S'PcoRTo G\. wurM 0wc No. RLV N. Lc 08 B iO Luis R. Lomas P.E. FL No.: 62514 DATE sNEE1549NTS12/29/14 4 OF 11 L R01WRTOL01114SP:E. WWWOODFORDROLEINSVILLENC27023 434{dB g dWrelPlIOMM& WM 1/2' MIN EDGE DISTANCE MET STRUCTU BY OTHE APPROVED SEALANT 1/4' MAX. SHIM SPACE 1T ICI f10 SMS OR SELF DRILLING SCREW INTERIOR EXTERIOR SILL TO BE SET IN A BED OF APPROVED STRUCTURAL BACKER ROD SEALANT APPROVED SEALANT i/4' MAX. SHIM SPACE METAL STRUCTURE BY OTHERS VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES., 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2, PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE W UN ASTM E2172 REV6gNS DESCRIPTION DATE N'PR0vm REVISED ANCMDR SPACING & CHARTS 07/11/16 R.I REVISED GLASS 10/02/17 R.L. 1/4' MAX. SHIM SPACE 10 SMS OR INTERIORSELFDRILLING SCREWS EDGE DISTANCE T - EXTERIOR METAL STRUCTURE BACKER RODBYOTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS DR+uoN: DNC nro. N.G. 08-02549 srxE NTS IDA" 12/29/14 Is"`-E' S OF 11 L ROBERTO LOSLISAE mV%lDOOFDRDRDLEK7SVaLF, NC2?0n 439-M-0809 tft m*&bmms;w com SIGNED: 1211412017 p T4AATT rrE OF ; e*1 i/ FSSIO0A 1'aG\`\ Luis R. Lomos P.E. FL No.: 62514 2 1/2" MIN. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS 1 1/A- MIN OPTIONAL IX BUCK ° EMBEDMENT 1 1/4' MIN. SEE NOTES 3 - 7 EMBEDMENT SHEc1 tfi 1 i CONCRETE/MASONRY 1 BY OTHERS J1/4" MAX. BACKER RODSHIM SPACE APPROVED ° SEALANT 3/16" IAPCON 3/16' TAPCON _\ II o , 2 1/2' MIN EDGE o DISTANCE MSCMPWN WE I APPRWO REVISED ANCHCR SPACING & ChARTS 07/11/16 RL REVISED CLASS 10/62/t7 R.L. t 1/4" MAX. SHIM SPACE INTERIOR 1 BACKER ROD EXTERIOR APPROVED OPTIONAL 1X BUCK SEALANT SEC NOTES 3 - 7 SHEET I JAMB INSTALLATION DETAIL C0NCRETE4MSONRY INSTALLATION SILL TO BE SET IN A BED OF NOTES: i.INTERIOR AND EXTERIOR FlWHES, BY OTHERS, BACKER ROD APPROVED NOTSHOWNFORCLARtTY APPROVED STRUCTURAL 2 PERIMETER AND JOINT SEALANT BY OTHERS TOBE SEALANT SEALANT DESIGNED IN ACCORDANCE WITHASTM E2112 SIGNED: 12/14/2017 OPTIONAL 1X BUCK 1/4- MAX. MI WINDOWS AND DOORS, LLC 11 II11/// SEE NOTE 3- 7 SHEET 1 F SHIM SPACE 650 ST MARKET YS R L O J\ 4/ 9 GRATZ,PA 17030-0370T GENSF CONCRETE/ MASONRY SERIES 185 ALUMINUM SINGLE HUNG WINDOW D 5 BY OTHERS r 52" X 72" NON -IMPACT FLANGE INSTALLATION DETAILS 0E TATOf i 0' FS, r• 10ROt OIGwN• we 40. REV G\w e ° 06190- T69 B s/0111 111?\\`\ suENTSo"I` 12/29/14 OF 11 VERTICAL CROSS SECTION LE Luis R. Lomas P.E. CONCRETEMASONRYINSTALLATTaN04YWOMFORDRDLE1uVas3PNC27023FLNo.: 62514 43't-W5,06"dunasobvinavocam 13 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD R APPROVED SEALANT BACKER ROD APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY 07HERS 1/2• MIN EDGE DISTANCE SPACE 110 WOOD SCREW SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4• MAX. SHIM SPACE r VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: I. W-JERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE MTN ASTM E2I 12 1 1/4' MIN. EMBEDMENT 1 1/2" MIN EDGE DISTANCE t O WOOD J SCREW / RENSIDNS DESCRPTCN MTE APPROVED REVISED ANCHOR SPACING k CHARTS 107/11/16 I R.L. REVISED CLASS 10/D2/17 R.L 1/4' MAX. SHIM SPACE INTERIOR WOOD FRAMING EXTERIOR OR 2X BUCK BY OTHERS BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLADON SIGNED: 1211412017 MI WINDOWS AND DOORS,LLC II 1flRLS0WESTMARKETEt5 EGRATZ, PA 17D30-0370 G NSA91P' p,.6 5 *= SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON -IMPACT k/if FINLESS INSTALLATION DETAILS STATE OF Dawn. INC No Rcv N.G. 08-02549 B SIOttiP Z OCNOAR` NTS Luis R. Lomas P.E. FL No.: 6251 a AE 12/29/14 027 OF 11 L ROBERTOLOVAS RE IM WtOODFO W RD LEVASVILLE. NC 2TA23 s,.aps w Idwres,i•Homaspemm METAL STRUCTURE BY OTHERS APPROVED SEALANT BACKEI APP SE STRUT BY 0 1/2• MIN EDGE DISTANCE 1/4' MAX. SHIM SPACE ft.. — OR SELF DRILLING SCREW R VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES, I. INTERIOR AND EXTERIOR FINLSHES, BY OTHERS, NOT SHOWN FOR CURT: 2 PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4' MAX. SHINI SPACE 11LV190:15 DLxR IrM DOE •DPRWO REVISED ANChOR SPACING R CHARTS 07/11/15 R.L. REVISED CLASS 10/02/17 R.L. 1/4• MAX. SrIlm SPACE 10 SMS OR INTERIOR SELF DRILLING SCREWS T_ 1/2' MIN. EDGE DISTANCE 1 EXTERIOR METAL BACKER ROD STRUCTURE h APPROVED BY OTHERS SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE WSTALLA77ON SIGNED: 1211412017 MI DOORE LLC 11 111LJ0ssoDOWTMARKETD 'T cSTR9 /// GRATZ, PA 17030-0370 GENSF s+y y o,,61251 SERIES185ALUMINUMSINGLEHUNGWINDOW52" X 72" NON -IMPACT FINLESS INSTALLATION DETAILS Z o', g$TAT OF O. F••'( 0RIOP• oHpwrtLmcno. REv US 02 B s /0NA `1 1G` scut are s Lcr549 NTS12/29/14 8 OF 11 Luis R. LomOs P.E. FL NO.: Ei251d L ROBERTO LOMS PE SAW WOODFORD RO LEIWSVRLE NC 27023 439- w'aw r0ara Jummo m" 2 1/2- WIN. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS e a e OPT1 1/4" MIN IONAL 1X BUCK ' . ` EMBEDMENT SEE NOTES 3 — 7 SHEET 1 H 1/ 4- MAX. BACKER ROD SHIM SPACE h APPROVED SEALANT 3/ 16- TAPCON 1 1/4" LAIN. EMBEDMENT CONCRETE/ MASONRY BY OTHERS 3/ 16' TAPCON 2 1/2" MIN. EDGE DISTANCE i o Jiv REIISIONS DESCIaPWN GUE APPRWED REVISED ANOM SPACING & CHARTS 07/11/16 R.L. P- l4SEDGLASS 110/02/17 J R.L. OPTIONAL 1X BUCK SEE NOTES 3 — 7 SHEET 1 MAX. SHIM SPACE INTERIOR EXTERIOR BACKER ROD k APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETFAMSONRY INSTALLATXNI r SILL TO BE SET BACKER R00 APPROVED IN A BED OF APPROVED NOTES: 1 INTERIOR AND EXTERIOR F/NISHES, BY OTHERS, SEALANT STRUCTURAL SEALANT NOT SHOWN FOR CLARITY. 2. PERREE7ER AND JOWT SEALANT BY OTHERS TO BE OPTIONAL IX BUCK 1 / 4 - MAY DESIGNED INACCORDANCE WITH ASTAf E2112 SEE NOTE 3 — 7 SHIM SPACE SIGNED: 1211412017 SHEET 1 T MI WINDOWS AND DOORS, LLC 1 1 11111/If/, LO CONCRETE/ MASONRY 650 WEST MARKET STREET GRATZ, PA 17030-0370 SIR BY OTHERS y SERIES 185 ALUMINUM SINGLE HUNG WINDOW F 0,, 6126 a - • 52" X 72" NON —IMPACT 1 n •, FINLESS INSTALLATION DETAILS y_D7ATE OF a DRAWN DYIII 1:0. R[v 0 i'° FS;( OR10P G\ 08 VERTICALCROSS SECTION scNt NTS D'TE 12/29/14 SmEC"99 OF 11 CONCRETEAUASONRY INSTALLATION L ROSERTOIDNASF. E. I492w000F4ROROLEKIML&AC27029 Luis R. Lomos P.E. FL No.: 62514 434-w-mg mxrd3vk mr *cm APPROVED SEALANT BEHIND FIN i 7/16* MIN jpp EDGE DISTANCE YI 7/16- MIN EDGE DISTANCE APPROVED SEALANT BEHIND FIN GMDL V ML1 1 VERTICAL CROSS SECTION WOOD FRWINIG OR 2X BUCK INSTALLATION VCOD RAMING 3Y OTHERS 1/4• MAX. SHIM SPACE WOOD FRAMING BY OTHERS 1 1/4• MIN. EMBEDMENT T— I APPROVED SEALANT BEHIND FIN 7/15' MIN EDGE DISTANCE MISIONS 4M DESCWRCm MTE APPROVIZ A REVISED AMCMOR SPACING & CIORTS 07/11/16 R.L. B REVISED GLASS 10/02/17 RL. 1/4' Ll4X r SHIM SPACE 8 WOOD SCREW INTERIOR EXTERIOR JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION NOTES. 1/4- MAX 1. INTERIOR AND EXTERIOR FINISHES. BY OTHERS. SXIM SPACE NOT SHOWN FOR CLARITY. 2. PER/MEET ER AND JOWT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE V4TH ASTM E21 I2 MI WINDOWS AND DOORS, LLC 6SO WEST MARKET STREET WOOD GRATZ, PA 17030-0370 FRAMING BY OTHERS SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52' X 72" NON —IMPACT FIN INSTALLATION DETAILS ORAi t N. G. 08-02549 SWL NTS I o`'M 12/29/14 1 swLT 10 OF t 1 L RWER7O LOM4S P.0 1- 72 WOODFORD AD LE1t'1S VIIIE: AIC 270M 4344 b-0609 19vr cam SIGNED. 12/14t2017 1It ! 1` 0/ i T eRF BONA 11 G` Luis P. Lomos P.E. FL No.: 62514 2 13/16" FLANGE FRAME HEAD CM• 18501 ALUMINUM 6063-T5.050' THICK 3/16" 2 3I/ 16' i FLANGE FRAME JAMB CM•18503 ALUMINUM 6063-T5.050' THICK 2 5/ 16' --j J_ FLANGE FRAME SILL CM-18502 ALUMINUM 6063-TS.05S•THICK 1 1 5/8- r 1 LIT LOCK RAIL/STILE CM-18505 At 6M3-T5.06T THICK 1" GLAZING BEAD CM-18535 RIGID PVC .OSO' THICK FINLESS FRAME SILL CM•18554 ALUMINUM 6063•T5.055' THICK F-- 1 1 7/16' I 2 5/16" L SASH BOTTOM RAIL CM-1855S ALUMINUM 6063-TS .OW THICK 1 --{ 1 3/8' 15/16' Cj SASH STILE CM-18W7 ALUMINUM 6083-TS .0150' THICK 2 3/16' 1I 5/16' LTJ 1 FINLESS FRAME HEAD CM•16553 ALUMINUM 6069-T5.050' THICK 2 3/16' f FINLESS FRAME JAMB CM-18513 ALUMINUM 6063•T5.050' THICK 2 5/16" --I 2 1/16' --J 3 3/4' rl FIN FRAME SILL FIN FRAME HEAD CM• 18509 CM-185" ALUMINUA46053-T5.055'THICK ALUMINUM 600-TS.050' THICK 1/a" J L MEETING RAIL CM• 18501 ALUMINUM 6063•T5.055' THICK 2 3/8" r 2 3/16' FIN FRAME JAMB CM-18510 ALUMINUM 606345.050• THICK I m I DESCRiPTON I DATE I APPROMM A REMED ANCHOR SPACING i CtWF:1S O7/1 i/16 R.l. 0 1 R15SCD CLASS 10/02/17 R.L. 5/8- 1 8- ANN. 1/8" ANN. 1/8' ANN 090 PV9 BY KURARAY METAL REINFORCED BUTYL SPACER EXTERIOR I INTERIOR 1/2" B11= SILICONE SEi1iuG BLOCK GLAZING DETAIL MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT COMPONENTS N.G. 1 08-02549 Su.L NTS 9A7L 12/29/14 ISKE711 OF 11 L ROBERTO LOU" P.E. 1,132 KOODFORD RD LEi179VLL6 AC 27W3 43 .6mobns ffl nwBswnuaw'MM SIGNED. 7211412017 R L O /' iC.EN`SF'9'r 0 5 * = TATE O0R O aG\` Luis R. Lomas P.E. FL No.: 62514 Florida Building Code Online https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVX... 1 Business & Professional Regulation Kira BCIS Home 1 Log In , user Registration I Hot Topics I Submit Surcharge I Scats a Facts publication FSC Stag I SCIS Ste Map I Links Search I Product Approval USER: Public UserdNr PtWIJst,AMnXaI Menu > Plodra2 ur AOWImdpLSS8ff.1] > A,pplk-#llgfLWt > Appheation DetaR FL # FL15349-R10 Application type Editorial Change Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 717)365-3300 Ext2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year AAMA 506 2011 AAMA/WDMA/CSA 101/1.S. 2/A440 2008 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A 1 of 3 4/ 13/201 R, 7:21 AM Florida Building Code Online https://www. (loridabuild ing.org/pr/pr_app_dtl.aspx?palam=wGEVX... Date Submitted Date Validated Date Pending FBC Approval Date Approved of Products FL # I Model, Number or Name 03/26/2018 03/26/2018 03/27/2018 Description 15349.1 1 185 PW 73 x 72 Insulated Glass — Limits of Use Certification Agency Certificate — Approved for use in HVHZ: No FL15349 R10 C CAC APC 12786,12787.pdf Approved for use outside HVHZ: Yes I Quality Assurance Contract Expiration Date Impact Resistant: No 04/03/2023 Design Pressure: +60/-60 Installation Instructions Other: CW-PG60 FLIS349 R10 11 QQ- 2357B.pdf Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL1S349 R10 AE 5131248.odf I Created by Independent Third Party: Yes 15349.2 185 PW 159 x 54 Triple CHS Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No I FLIS349 R10 C CAC APC 153,pd Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 01/24/2021 Design Pressure: +55/-55 Installation Instructions Other: R-PG55 FL15349 R10 II 08-02949.odf Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL15349 R10 AE 513783.odf 15349.3 1185 PW Impact Limits of Use — Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-55 Other: FW-LC55, Missile Level D, Wind Zone 3. Glass consisted of 5/32" tempered exterior - spacer - 5/32" annealed / 0.100 Solutia Sanex HP / 5/32" annealed. Glass was bedded In Pecora 896 silicone with S/8" glass bite. Created by Independent Third Party: Yes 72 x 72 Insulated Laminated Glass ^ Certification Agency Certificate _ — FL15349 0 C CAC AP 1 454odf Quality Assurance Contract Expiration Date 06/25/2021 Installation Instructions FL15349 R10 II 08-02948.pdf Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports EL15342 RIO AE 513782.od( Created by Independent Third Party: Yes 15349.4 185 PW Impact 159 x 54 Triple CHS Insulated Laminated Glass Limits of Use - —_ — --- - - - — --- It Certification Agenq Certificate Approved for use in HVHZ: No FLIS349 R10 C CAC APC 8272.odf I Approved for use outside HVHZ: Yes FL15 49 R100 CAC Apr 8273.odf Impact Resistant: Yes Quality Assurance Contract Expiration Date Design Pressure: +SS/-55 01/24/2021 f Other: FW-1155, Missile Level D, Wind Zone 3. Glass Installation Instructions j consisted of 1/8" annealed exterior - spacer - 3/32" annealed FLI5349 R10 It 08-016148.pdf S / 0.090 Solutla PVB / 3/32" annealed. Glass was bedded in Verified By: Luis Roberto Lomas 62514 1 Pecora 896 silicone with 5/8" glass bite. I Created by Independent Third Party: Yes f Evaluation Reports FLIS349 R10 AE 512278B.pdf Created by Independent Third Party: Yes 185 PW Impact Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure, +55/-55 Other: FW-LC55, Missile Level D, Wind Zone 3. Glass consisted of 5/32" annealed exterior - spacer - 5/32" annealed / 0.100 Solutia Safiex HP / 5/32" annealed. Glass was bedded in Pecora 896 silicone with 5/8" glass bite. 96 x 60 Insulated Laminated Glass Certification Agency Certificate FLIS349 R10 C CAC APC 7962.odf Quality Assurance Contract Expiration Date 12/0S/2020 Installation Instructions FLIS349 R10 It 08-91 13B pd Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports 2 of 3 4/13/201817:21 AM Florida Building Code Online https://www. Floridahu ild ing.org/pr/pr_app_dtl.aspx?param=,.vG GVX... 5-122778.dfo Created by Independent Third Party: YesIFL15349RIOA9 0 neae Contact Us ;; ZGlulLmk Stone Road. nnawssee FL 32399 Phone: 850-487-1824 The State of Flonda is an AA/EEO employer, Cownaht 2007-2013 State of Florida.:. Prtvaw S p,Ot :: rpSsbdRv Statement :: Refund Statement Under Florida taw, email addresses are public records. V you do not want your e-mal address released In response to a pubic -records request, do not send electronic mall to "I enUty. Instead, Contact the office by phone or by traditional malt V you have any questions, please contact 850.487.1395. •Pursuant to Section 4S5.275(t), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4S5, F.S. must provide the Department with an emal address If they have one. The emads provided may be used for alfMal communication wth the licensee. however emal addresses are public record. V you do not wish to supply a personal address, please provide the Department with an emal address which can be made avalable to the public. To determine If you are a licensee under Chapter 4S5, F5, please click bla. Product Approval Accepts: R Credit Card Safe 3 of 3 4/13/2018, 7:21 AM NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. B. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL-• EXTRUDED ALUMINUM 6063-T5. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #6 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. REVOONS DESCRFWN I WE I APP110+EO REVISED INSTALLATION DETAILS 06/01/15 R.L REVISED NAME AND ADDRESS 1 10/27/15 R.L 15.FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT. 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048) FY-33KSI/FU-52KSI OR ALUMINUM 6063-T5 FU=30KSI .048" THICK MINIMUM 20. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN IN SHEET 2. TABLE OF CONTENTS SHEET NO. DESCRIPTION 1 I NOTES 2 - 3 ELEVATIONS. CHARTS AND GLAZING DETAILS 4 - 12 INSTALLATION DETAILS SIGNED: 1117512016 MI WINDOWS AND DOORS, LLC AAA tiIIIAArr 650 W. MARKET ST. J\S R. . O,J_'/ GRATZ, PA 17030 GENS-.'9s J 0, 8 51/tSERIES185ALUMINUMFIXEDWINDOW 73" X 72" NON -IMPACT NOTES livDOS•• STATES OF • ` PF •' c[DR10: • \' i//s', DRWW. DwG NO. REV OB- 57 B ONA„Fl1G\• Luis R. Lomas P.E. FL No.: 62514 scat as NTS09/03/14 1 OF 12 I AIWERTOLCIMAISAF 14M WOODFOW RO 1i1NS14M E NC 270M 494. 6M4609 lXw=V *W Wpf.=0 6' MAX 72 1/2' MAX FRAME WIDTH 18" MAX O.C. 6- MAX L jte' MAX O.C. 71 1/2- MAX FRAME HEIGHT REFER TO CHARTS SERIES 185 ALUMINUM FIXED WINDOW 11 & B2 EXTERIOR VIEW FOR NUMBER OF ANCHORS REQUIRED 6' MAX 72 1/2' MAX FRAME WIDTH 18" MAX O.C. 6" MAX t 71 1/2' 18' MAX MAX O.C. FRAME HEIGHT j j REFER TO CHARTS SERIES 185 ALUMINUM FIXED DESIGNER WINDOW 1 & 02 EXTERIOR VIEW FOR NUMBER OF ANCHORS REQUIRED DESIGN PRESSURE AATING IMPACT RATJNG 60.OPSF NONE NOTES: I. MAXlJWUATD.LO.: 69X4•X683u' REVt9R+S REV DESUMP110N DATE AVPROVO A REVISED INSTALLATION DETAILS 06/01/15 1 R.L. 8 REVISED NAME AND ADDRESS 1 10/27/16 1 R.L. CHART S7 Number o7 Dnchor3 r"W rod Without d9ld 8H Prom. Prm. width (InH Height 2400 3400 3400 1 42.00 4&00 1 S400 M00 1 "00 7150 Hnl HSS mb HAS jamb HAS VSMDI HAS JAMD HAS I.Ambl HAS Jamb HAS Jamb HAS Almb HISS JaMb 24,00 2 2 1 2 2 3 2 1 3 2 3 2 1 4 2 4 2 4 2 S 2 30.00 2 2 2 2 3 2 3 2 3 2 4 2 4 2 4 2 S 2 J400 2 3 2 3 3 3 3 3 3 3 4 3 4 3 S 3 3 3 42.00 2 3 2 3 7 3 3 3 3 3 4 3 S 3 S 3 6 3 A.00 2 3 2 S 3 3 3 3 3 3 S 3 0 3 0 3 S•.00 2 4 3 4 3 4 3 4 4 4 S 4 6 4 7 4 Moo 2 x 4 3 4 s s s s e s7 sMoo2243S4EP36e367071.50 2 S 2 S 3 S e e 7 S 7 9 T 7 7 CHART J2 Number o/ anchors required (with rlg)d 6llerV Frm. Frm. width N) Height 2400 1 10.00 1 34.00 1 4100 4400 54.00 8100 ee,ao 72.W in) HAS jambi HAS LIemb HAS jamb Ir&S V&mb HAS Amb HAS mD HAS Jamb HAS pamb HS9 iamb 240D 2 2 2 2 3 2 3 2 3 2 2 4 2 4 2 S 2 30.00 2 i 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 3e.00 2 S 2 3 3 3 3 3 3 3 4 3 4 3 4 3 5 3 42.00 2 3 2 3 3 3 3 3 3 3 3 4 1 3 S 3 41.00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 4 3 S 3 M00 2 4 2 4 3 3 4 3 4 4 4 4 4 4 S 4 00.00 2 1 2 3 3 4 3 4 4 4 1 1 4 4 S 4 Moo 2 4 2 1 3 4 3 4 3 1 1 4 4 4 S 4 7I6 2 S 2S3 3 5 1 S 4 S S S SEE SHEETS 4-7 FOR INSTALLATION DETAILS Ml WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FLANGE & FINLESS ELEVATION & CHARTS DPAeM. M No. J.L. 1 08-02357 5 NTS JDATE 09/03/14 S"W 2 OF 12 L HOBERM L014AS RE 143V W000FOM RD LENISVILLE IOC 27M 4J4-Be6.0609 dbaxtsobibmwit•00m SIGNED: 11/15&016 0S111fttIIil0 `\`` 0 •6 25 * = PATE OF ; 1 jP(ORIOP• S10NA 1 aG\`• Luis R. Lornos P.E. FL No.: 62514 71 FI Hi 6' MAX 72 1/2- MAX FRAME WIDTH 18" MAX O.C. —{ I 6- MAX I L t8' jMAXO.C. 1/2- IA1( AME IGHT 6" MAX REFER TO CHART g3 SERIES 185 ALUMINUM FIXED WINDOW FOR NUMBER OF EXTERIOR VIEW ANCHORS REOUIRED 72 1/2' MAX FRAME WIDTH _: L6' MAX -- 18" MAX O.C. 6" MAX j MAX O.C. 71 1/2- MAX FRAME HEIGHT REFER TO CHART #3 FOR NUMBER OF SERIES 185 ALUMINUM FIXED DESIGNER WINDOW ANCHORS REOUIRED EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING 360.0PSF NONE NOTES: I. AIAXIMUMD.LO.: 69314•X583w RflEDNS REV OESCPoPOON DAZE APPROVED A REVISED INSTALLATION DETAILS 06/01/15 R.L. 8 REVISED NAME AND ADDRESS 10/27/1E R.L. CHARTAO Number of anchors requirod n Insmlradon Rome Frone vIdlh (m) Might U.00 0.00 5A.00 42.00 4a.00 0 ao.00 66.00 2LSO in) HAS Pamb HAS Jamb HAS Jamb HAS Jembl NLS Jamb HAS I&nMl His Loamb Ht5 Jamb HLS Pamb 2400 3 3 3 3 3 3 4 3 3 3 SIm 3 0 3 2400 3 3 3 3 3 3 4 3 4 3 4 3 5 3 6 3 36.00 1 3 3 3 3 3 4 3 4 3 4 3 S 3 0 3 4200 3 4 3 4 3 4 4 4 4 4 4 4 5 4 6 9.00 3 3 3 4 4 4 4 4 S 4 0 4 54.00 3 3 4 3 4 4 4 4 4 4 5 4 s 4 0 w 3 5 3 5 1 5 4 5 4 5 S 500.00 3 S 3 5 3 5 4 S 4 5 5 5 6 5 21.50 3 6 3 6 3 0 4 6 8 4 0 5 5 1 0 1 0 0 SEE SHEET 8 FOR INSTALLATION DETAILS MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73' X 72" NON —IMPACT FIN ELEVATION & CHART ORAMN aA6 N0. J.L. 1 08-02357 swc NTS ° 09/03/14 1 s""3 OF 12 L AMMO L03U5 RE 432 NOOOADRD RD LEINSVIILE. HC 2?= 43• SW-O 09 A m iMmatr».cem SIGNED: 1111512016 J\ S11.IILfo STATE Lu 0. iss o0ylo aG\` 11111101 Luis R. Lomas P.E. FL No.: 62514 NTERIOR 1/2' MIN. EDGE DISTANCE WOOD FRAMING 1 1 1/4- MIN METAL STRUCTUREOR2XBUCKEMBEDMENT BY OTHERS BY OTHERS 1 i 1/4" MAX. J BACKER ROD SHIM SPACE BACKER ROD APPROVED ScAPPROVED SEALANT SEALANT 10 WOOD SCREW EXTERIOR EXTERIOR 10 WOOD SCREW BACKER ROD RIGID FILLER BACKER ROD — APPROVED 1/4- MAX APPROVED SEALANT r I I SHIM SPACE SEALANT WOOD FRAMING I' I 1/4' MIN. OR 2X BUCK BY OTHERS EMBEDMENT S UMETAR cBYOTHERS 1 /2" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMWG OR 2X BUCK INSTALLATION 1 1/4" MIN. 1/4- MAX. EMBEDMENT F SHIM SPACE T 1/2MIN. EDGE DISTANCE INTERIOR I110 WOOD U SCREW WOOD FRAMING EXTERIOR OR 2X BUCK BY OTHERS BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION 3/ 4- MIN. EDGE DISTANCE 10 SMS OR SELF DRILLING SCREWS METAL EXTERIOR STRUCTURE BACKER ROD BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION 3/ 4- MIN EDGE DISTANCE 1 / 4' MAX. SHIM SPACE 10 SMS OR SELF DRILLING SCREW INTERIOR 0 SMS OR SELF DRILLING SCREW RIGID FILLER t/ 4' MAX. SHIM SPACE d IIII-------- t-ttl- 3/4" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION 1/ 4" MAX. SHIM SPACE INTERIOR RA751G6 slr xsmproN oATt: APPRMO A REVISED INSIALLATICN DMAuS 06/01/I5 R.L. B REVISED NAME AND ADDRESS 10/27/16 R.L NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM C2712 SIGNED: 1111 &2016 DOORS, LLC MIWINDOWwa ltI,% MNDX GRATZ. PA 17030 5 v • GENS 9jI 0y 2 5 SERIES185ALUMINUMFIXEDWINDOW73" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS WITHOUT FILLERS 0 STAT OF /v` G OpAlworcNoilVJ. L. OS B S.(ORlO? ZONAL: 1 lli Luis R. tomes P.E. FL No.: es DATE SOm357 SmcNTS09/03/14 4 OF 12 L ROBERT0t0MASP.E I4J2 WOODFORD RD LMSWIJA LLC 27G2! 4J - W,0W9 dbnnA6eh7m=v, om CONCRETE/MASONRY BY OTHERS CPTIONAL 1X BUCK SEE NOTES 3 - 7 SHEET I BACKER ROD APPROVED SEALANT EXTERIOR BACKER ROD -. APPROVED SEALANT OPTIONAL 1X BUCK SEE NOTE 3 - 7 SHEET 1 CONCRETE/LSASONRY BY OTHERS 2 1/2" MIN. EDGE DISIANCE 1/4' MAX. SHIM SPACE 3/W TAPCON INTERIOR 3/16' TAPCON REASIONS RLv DESORPII04 DATE FPROJ[0 A REVISED INSiAUATION DETAILS 06/01/15 R.E. H REVISED NAME AND ADDRESS 10/27/16 Ft.L i 1 1/4" MIN. y t 1/4' MIN. EM6E051ENi EMBEDMENT I a CONCRETE/MASONRY BY OTHERS 1/4' MAX. a SHI:A SPACE OPTIONAL 1X BUCK ' SEE NOTES 3 — 7 SHEET 1 1/4' MAX. FSHIM SPACE II a . 1 1/S' MIN a EMBEDMENT 2 1/2• MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETE/MASONRY INSTALLATION 3/16" TAPCON a • INTERIOR 2 1/2' MIN. o ' EDGE DISTANCE EXTERIOR BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETE90SONRY INSTALLATION NOTES' I. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2 PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 1703D SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON -IMPACT FINLESS INSTALLATION DETAILS W17HUT FILLERS OAAhN _wc NJ. R J.L 08-02357 SCALE NTS o`n 09/03/14 1-5 OF 12 L. RO8ERTOLOAIAS P.E 14M WOODFDRD RO LEWLSVRtE. ABC 27023 u -6W-O Ds 4WnasQatmzop@oam SIGNED: 11/15/2016 C, R I I LI0 q 5'D E OF u ORIoP i S ONA 11E\n Luis R. Lomos P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD k APPROVED SEALANT EXTERIOR BACKER ROD k APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 1/2" MIN. EDGE DISTANCE 1 1/4' MIN. S EMBEDMENT 1/4" MAX. SHIA SPACE RIGID FILLER 010 WOOD SCREW INTERIOR 10 WOOD SCREW RIGID FILLER 1/4" MAX. SHIM SPACE 1 1/4- MIN. EMBEDMENT 1/2' MIN. EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4' MIN. _ 1/4" "1 EMBEDMENT SHIM SPACE 7- 1RIGID FILLER 1/2• MIN. EDGE DISTANCE INTERIOR p 10 WOOD SCREW WOOD FRAMING EXTERIOR OR 2X BUCK BY OTHERS BACKER ROD k APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION M ETAL STRUCTURE 6Y OTHERS SACKER ROD k APPROVED SEALANT EXTERIOR BACKER ROD k APPROVED SEALANT METAL STRUCTURE BY OTHERS T_ 1 3/4- MIN. EDGE DISTANCE L _ IE MIN r" EDGE DISTANCE III 1/ 4" MAX L r SHIM SPACE T 1RIGID FILLER j10 SMS OR SELF DRILLING SCREW INTERIOR 10 SMS OR SELF GRILLING SCREW RIGID FILLER 1/ 4" MAX. SrIM SPACE 3/ 4" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTUREINST.4LL1T)ON 1/ 4" MAX. FSHIM SPACE RIGID FILLER I /_ INTERIOR 10 SMS OR J SELF DRILLING SCREWS EXTERIOR METAL STRUCTURE BACKER ROD BY OTHERS k APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLA17ON 4. 14510.4s RN DESCRIPWN DkIE I APPRMED A REVISED INSTALUTICN DETAILS 40n/01/I5 R.L 1 B I REVISED NAME AND ADORESS 10/27/16 R.L. NOTES: 1. INTERIOR AND EXTERIOR FINISHES. BY OTHERS, NOT SHOWN FOR CLARITY 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E21 I2 SIGNED. 1111512016 MI WINDOWS AND DOORS, LLC 11t11'ILi/ 650 W. MARKET ST.GRAT PA 17030 J\SVGENS9J' F• SERIES 185 ALUMINUM FIXED WINDOW 44ATi 51TLL X72" TONSIMPACT INSTALLATION DETAILS WITH RIGID FILLERS arfFINLESS DOf OlORlO;• ' 1` ORa?l: arr, No RN OB 8 7101VALS?G\`\ uLENTSDcrE09/03/14 67 OF 12 L ROBERTO LOWS P.E 1r92 WOODFORD RD LEINSVD.L6, NC 27M Luis R. Lomos P.E. FL No.: 62514 434E88. OW-%vrua64b My mm REVISIONS RLV DESCRMON COTE PRWLO 2 1/ 2• MIN. A JRLVISED INSTALLATION DETAILS D6/01/15 R.L. EDGE DISTANCE B RfWsc'D nAe1E AND ADDRESS 10/27/16 R.L. CONCRETE/MASONRY BY OTHERS 1 1 1/4" MIN. I 1 1/4' MIN. EMBEDMENT OPTIONAL IX BUCK EMBEDMENTSEENOTES3 - 7 SHEET 1 T I1 0 1 J CONCRETE/MASONRY BACKER ROD 1/4* MAX. BY OTHERS 1/4' MAX. APPROVED SHIM SPACE SHIM SPACE SEALANT OPTIONAL 1X BUCK RIGID FILLER SEE NOTES 3 - 7 SHEET t RIGID FILLER 3/i5" TA?CON EXTERIOR INTERIOR 3/16' TAPCON INTERIOR 3/16 TAPCON BACKER ROD SEALANT RIGID FILLEP. I/4" MAX. 2 1/2 OPTIONAL 1X BUCK SH1M SPACE WIN. SEE NOT_ 3 - 7 1 GE aSHEET1DISTANCE EXTERIOR CONCRETE/MLASCNRY BACKER ROD BY OTHERS n 1 1 1/4' MIN. APP ROVED a EMBEDMENT JAMB INSTALLATION DETAIL CONCRETE444SONRYINSTALLATTON 2 i/2' MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONfCREJF_/AMSONRY INSTALLATION NOTES: T. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E?112 SIGNED., 1111512016 MI WINDOWS AND LLC Ilk Ito// 0 W. MARKETDOORS, y vGRATZ, PA 17030 GENSFgJ' 5 SERIES 185 ALUMINUM FIXED WINDOW*• 7LL X 72" NON -IMPACT x st62 MTAVFINLESSINSTALLATIONDETAILSWITHRIGIDFILLERS O OF•'Q(ORIOP• iONA aura: G ro gEv 02 1111tB1tEG Luis R. Lomos P.E. FL No.: 62514 s:xc NTS °">E 09/03/14 lwc08 77Of12L ROBERTO LOWS RE 1rnWOODFORDRDLA" SWLL NC27= 4Jr4W-= 0 rO kftMWMX*M WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT BEHIND FLANGE 1/2" MIN. EDGE DISTANCE 1 1/4" MIN. EMBEDMENI t/4" MAX. SHIM SPACE 110 WOOD SCREW 3/4^ MIN METAL STRUCTURE BY OTHERS BACKER ROD & APPROVED SEALANT BEHIND FLANGE 1/4" MAX. SHIM SPACE 10 SMS OR LF DRILLING REW CEVM S RN OEseRI%ION o.r IAPPRCAD A REVISED INSIAL ATION DETAILS 06/01/15 R.E. 2 Rt-ASiD NAVE AND ADDRESS 10/7.Tl16 I R.L EXTERIOR EXTERIOR INTERIOR INTERIOR 10 SMS OR J10 WOOD SCREW SELF DRILLING SCRE7I BACKER ROD A RIGID FILLER BACKER ROD & RIGID FILLER APPROVED SEALANT Ig 1/4" MAX. APPROVED SEALANT BEHIND FLANGE SHIM SPACE BEHIND FLANGE 1/4' MAX. SHIM SPACE NOTES. WOOD FRAMING 1 1/4 MIN. METAL 1.INTERIOR AND EXTERIOR FINISHES. BY OTHERS, NOTSHOWNFORCLAR/TYOR2XBUCKSTRUCTUREi BY OTHERS EMBEDMENT BY OTHERS 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE 3/4" MIN DESIGNED IN ACCORDANCE WITH ASTM E2112 1/2" MIN EDGE DISTANCE EDGE DISTANCE VERTICAL CROSS SECTION VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION WOOD FRAMING OR 2X BUCK INSTALLATION 1/4" MAX. 1 1/4" MIN. 1/4" MAX. SHIM SPACE EMBEDMENT SHIM SPACE T-- r I 1/2- I MIN 3/4' MIN. INTERIOR EDGE DISTANCE EDGE DISTANCE SIGNED., 1111512016 INTERIOROR MI WINDOWS AND DOORS, LLC LT111111I1I, 650 W. MARKET ST. NUJ It - LO?l9ii 10 WOOD I ID SMS OR GRAiZ. PA 17030 GEN,g +% SCREW SELF DRILLING SERIES 185 ALUMINUM FIXED WINDOW 0 5 SCREWS 73" X 72" NON —IMPACT WOOD FRAMING OR 2X BUCK EXTERIOR METAL EXTERIOR FLANGE INSTALLATION DETAILS WITHOUT FILLERS TAT OfO'G E ; BY OTHERS BACKER RCD & STRUCTURE BY OTHERS HACKER ROD & WAMI: Doc I'm J.L. 08-02357 BONAL i FS'cLOR10A GA\ APPROVED SEALANT APPROVED SEALANT 11111110% BEHIND FLANGE BEHIND FIANCE sac NTS DAT' D9/03/14 5Mw B OF 12 JAMB INSTALLATION DETAIL JAMB INSTALLATION DETAIL L. ROBERTOLOMASP.E. Luis R. Lomas P.E. WOODFRAMINGOR2XBUCKINS7ALLATI0N METAL STRUCTURE 114STALLA TION wvvAbOF0RDRDLEWISv1LE,NC27W3 FL No.: 625144N4aaw *ff4S bbnwps.aan RLVSCNS RLV DESCRIPIDN DAIE APPROVED 2 1/2• M:N. A REVISED INSEALLAIION DE1NLS 06/01/15 RL. EDGE DISTANCE B REVISED NAME AND ACDRESS 10/27/16 R.L. CONCRETE/MASONRY BY OTHERS a ' • • 1 1 /4" MIN. a 7 1 1/4' MIN, EMBEDMENT OPTIONAL 1X BUCK a EMBEDMENT SEE NOTES 3 — 7 SHEET 1 o CONCRETE/MASONRY BACKER ROD fc q• Mqx, 8Y OTHERS L_ 1/a" MAX. APPROVED SEALANT SHIM SPACE SHIM SPACE BEHIND FLANGE OPTIONAL tx BUCK — 4 SEE NOTES 3 — 7 ISHEET1 3/16" TAPCON a EXTERIOR INTERIOR 3/16" TAPCON INTERIOR 3/16" TAPCON EACKER ROD do APPROVED SEALANT BEHIND FLANGE I OPTIONAL 2MIN. SEE N07EX38-7 SHIM"SPACE o SHEET 1 11 DISTDDICE EXTERIOR CONCRETE/MASONRY BACKER ROD 6c BY OTHERS d APPROVED SEALANT a • a EMBEDMENT BEHIND FLANGE JAMB INSTALLATION DETAIL a o_T CONCRETEIMASONRYINSTALLATION d 2 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETSIMASONRY INSTALLATION NOTES. 1, INTER10RAND EXTERIOR FINISHES, BYOTHERS• NOT SHOWN FOR CLARITY. 2 PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2712 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS WITHOUT FILLERS MAW* DAt W. a J.L. 08-02357 CAL' NTS GTE D9/03/14 1 9109 OF 12 L AMATO LOMAS P.E. 14321KC00FORD RD LSWSYXa AC 27M SIGNED: I III 2016 EIDFf'iENS• 9ir' FOR10:• SS ONA 1E%G° Luis R. Lomas P.E. FL No.: 62514 1/2" MIN. RrAs;cNS tEDGE DISTANCEI ecv oc5c"non DATE AF WAII weoD FRAMING 1 1/4- MIN 3/4" MIN EDGE DISTANCE A FEVISED INSTALLATION DETAILS C6/01/IS R.L. OR 2x BUCK BY OTHERS EMBEDMENT STRUC URE B REVISED NAME AND ADDRESS 10/27/16 RL, BY OTHERS I q SHIM SPACE I 1/4" MAX J I BACKER ROD & SHIM SPACE BACKER RODAPPROVEDSEALANT BEHIND FLavCE RIGID FILLER APPROVED SEALANT RIGID FILLER 10 WOOD SCREW BEHIND FLANGE 10 SMS OR SELF DRILLING SCREW EXTERlQR EXTERIOR INTERIOR INTERIOR 10 SMS OR 110 WOOD SCREW SELF DRILLING SCREW BACKER R00 & RIGID FILLER BACKER ROD & RIGID FILLER APPROVED SEALANTiti 1/4- MAX. APPROVED SEALANT BEHIND FLANGE SHIM SPACE BEHIND FLANGE 1/4" MAX. r SHIM SPACE NOTES. WOOD FRAMING f METAL I INTERIOR AND EXTERIOR FWISHES.BYOTHERS. OR 2X BUCK 1 1/°" MIN. STRUCTURE NOT SHOWN FOR CLARITY. BY OTHERS EMBEDMENT BY OTHERS 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE I 3/4" MIN DESIGNED W ACCORDANCE WITH ASTM E2112 1e2" MIN EDGE DISTANCE STANCE VERTICAL CROSS SECTION VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION WOOD FRAMING OR 2X BUCK INSTALLATION 1/4- MAX. 1 1/4" MIN. 1/4" MAX. SHIM SPACE EMBEDMENT SHIM SPACE I RIGID FILLER I RIGID FILLER 3/4- MIN. INTERIOR1/2" MIN. EDGE DISTANCEEDGE DISTANCE SIGNED: 11/15 2018 INTERIOR MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ. oi,, S 1;ENS y9Ui 10 WOOD 10 SMS O4 PA 17030 F SCREW SELF DRILLING SERIES 185 ALUMINUM FIXED WINDOW z *• 0 5 x SCREWS 73" X 72" NON —IMPACT it. t1 OR 2X SUFRAMCK EXTERIOR METAL EXTERIOR FLANGE INSTALLATION DETAILS WIT RIGID FILLERS TAT OF BY OTHERS BACKER ROD & STRUCTURE BY OTHERS BACKER ROD do oaAwN. oAs No. atv 08 B tns+ •. , • , . ( D SEALANT APPROVEDSEALANT 50 n357BEHINDBEHIND9ouEoAT[ NTS 09/03/14 10 OF 12 JAMB INSTALLATION DETAIL JAMB INSTALLATION DETAIL L WRERTOLOMASP.E Luis R. Lomas P.E. WOOD FRAMING OR 2X BUCK INSTALLA TION METAL STRUCTURE INSTALLATION 1AWKOMFORORDLE1t181N.LENC2M3 FL No.: 6251A1344RIvmfftM*YbM=pe.CM 2 1/2• MIN. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS i •' a *. 1 1/4• MIN. OPTIONAL 1X BUCK ° ° EMBEDMENT SEE NOTES 3 - 7 SHEET 1 i BACKER ROD & APPROVED SEALANT BEHIND FLANGE EXTERIOR PACKER ROD & - APPROVED SEALA.YT BEHIND FLANGE OPTIONAL 1X BUCK - SEE NOTE 3 - 7 SHEET I CONCRETE/MASONRY - BY OTHERS 1 1/4" MIN EMBEDMENT CONCREI I/`• MAX I BY OTHERS SHIM SPACE J RIGID FILLER OPTIONAL IX BUCK SEE NOTES 3 - 7 SHEET 1 3/16- TAPCON INTERIOR 3/16" TAPCON 3/16" TAPCON RIGID FILLER mg 1/4" MAX. SHIM SPACE I 1 1/4• MIN. a EMBEDMENT a1 i e 2 1/2" MIN. EDGE NSTANCF. VERTICAL CROSS SECTION CONCRETEUASONRY INSTALI ATION 2 1/2" MIN. EDGE DISTANCE REVISIONS ary DESCRPTo" WTC I MPRLVED REVISED INSTALIATION DETAILS 06/01/15 R.L 3 REVISED NAME AND ADDRESS ID/27/16 R.L. e 1/4- MAX. a SHIM SPACE RIGID FILLER I o INTERIOR I EXTERIOR BACKER ROD & APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL CONCRETEMASONRY INSTALLATION SIGNED: 1111512016 MI WINDOWS DOORS, LLC lk 1I t o// NOTES 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS ow. MaaK GRAT2. PA t 7030 5 J q i r• G E NSF + NOT SHOWN FOR CLARITY SERIES 185 ALUMINUM FIXED WINDOW2. PERIMETER AND JOINT SEALANT BYOTNERSTOBE 0 St k DESIGNEDWACCORDANCE WRH ASTM E2t12 73" X 72" NON -IMPACT GO FLANGE INSTALLATION DETAILS WITH RIGID FILLERS r 0 TAT OF jOlos•r.IrIrul+c RErO F• OR0• o'OB-O ONA1E57e GNJ.L.SME 1 NTSDATE09/03/14 11 OF 12 Luis R. Lomcs P.E. LROBERTOLO.MAS RE I4wVf0ODF0RDROLEWI9VILLE. AC27029 434- 68 oaq 4Mk"VhbmaF+.CM FL No.: 62514 APPROVED SEALANT BEHIND FIN 86 WOOD SCREW 3/8' MIN jp f EDGE DISTANCE II I EXTERIOR 1 1/a' MIN. EMBEDMENT WOOD FRAMING BY OTHERS 1/4- MAX. SIIIM SPACE INTERIOR f 1/4' MAX j SHIM SPACE 3/8' MIN r— f EDGE DISTANCE 6 WOOD WOOD SCREW FRAMING APPROVED — 1 1/4• MIN. BY OTHERS SEALANT EMBEDMENT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION WOOD FRAMING 1/4' MAX BY OTHERS SHIM SPACE g6 WOOD5 lNTERfOR SCREW 1 1 1/4' MIN. EMBEDMENT APPROVED SEALANT BEHIND FIN EXTERIOR 3/8' MIN EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMM OR 2X BUCK INSTALLATION REVISIONS REV DESCRIPRON OAIE I APPROVED A RMSED INSTALLATION DETAILS 06/01/15 R.I. 9 I REMISED NAME AND ADDRESS 10/27/16 R.I. NOTES. 1. WTERIOR AND EXTERIOR FINISHES, BY OTHERS. NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE KITH ASTM E21 I2 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ. PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73' X 72" NON —IMPACT FIN INSTALLATION DETAILS DRAw-v DOG N0. J.L. 08-02357 Sc' NTS 0''1C 09/03/14 15mm 12 OF 12 L RMRT0 LOINS P.E. 142 W000F WD AD LEwSWLLE, AC 22 J IJa4C94609 dbmas@b*m*W&awm SIGNED. 1111512016 0S 1R I!L/0 9 e,•GENSJ+ pSE OF ; cc R10P• \ 0\ Luis R. Lomos P.E. FL No.: 62514 Florida Building Code Online https://www.floridabuil(ling.org/pr/pr app_dtl.aspx?patam=wGFVX... Business & ProfessidnalRegulation rid SCiS Home I log In I User Registration l Hot Topics Submit Surcharge I Stats a Facts I Publications I FOC Stag I SCIS Site Map I Links ( Search ; doprFlorida s Product Approval usea: Public user m4.,„K.,... Pnrdun Aoomvar Megy > pr MKtAL&=atlgn.SWa:b > 600katbn List > Application oetag FL # FL15353-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Luis R Lomas, PE the Evaluation Report Florida License PE-62S14 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Steven M. Urich, PE Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Validation Checklist - Hardcopy Received FL15353 R3 COI FLCOT.pf Standard AAMA 450 year 2010 1 of 4/13/2018, 7:26 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr app_dtl.aspx?parain=wGEVX... Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 10/16/2017 10/23/2017 10/26/2017 12/12/2017 FL !R Model, Number or Name _ + Description 15353.1 _ 15764 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". span: 104 1/4". 15353.2 15764 Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". span: 83----------------- Horizontal Aluminum Mullion I Installation Instructions EL1535-3 a3_ti 08_0j.448B.pdf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports Max mullion I FLi 53 R3 AE 512072B.odf Created by Independent Third Party: Yes—_ --- - iVertical Aluminum Mullion Installation Instructions F-L153i3_R3 t_Q8=0.143yB•odj Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports Max mullion I EL15353 R3 AE 51 0638.p f Created by Independent Third Party: Yes 15353.3 5765 I Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS353 R3 II 08-01449B.0df Approved for use outside HVHZ: Yes I Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes I Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353_-83_6B.SI20738.ndf span: 156-3/8" Created by Independent Third Party: Yes 15353.4 15765 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 li 08-014408.odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514IImpactResistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 5120640.odfjspan: 83". Created by Independent Third Party: Yes 15353.5 CM_18514- v- I Vertical Aluminum Mullion -- -- Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". Max mullion length - 83". 15353.6 CM-18520 Limits of Use -------. ...- -- •• ------------ Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other, Max single window size - 52-1/8" x 84" span - 156-3/8" Max mullion Installation Instructions fL15353 R3 II_08_014428.pdf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL15353 R3 AC 566f Created by Independent Third Party: Yes Horizontal Aluminum Mullion — Installation Instructions Et,15J553 R3 Il 08-014aB p f Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL15353 R3 AE 512075B.pd Created by Independent Third Party: Yes 15353.7 i CM-18523 _-- --_ Horizontal Aluminum Mullion --- -- 2 of 3 4/13/2018, 7:26 AM Florida Building Code Online https://www.floridabuild ing.org/pr/pr_app_dtl.aspx?pardm=wGEVX... Limits of Use Installation Instructions Approved for use in HVHZ: No FL15,3 IR3_lt Q6.=Q)t!L528.bd( Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL15353 R3 AE S12076B,pM span - 104-1/4". Created by Independent Third Party: Yes 15353.8 --- _ I CM-118531 J— -_ Vertical Aluminum Mullion ^ Limits of Use Installation Instructions Approved for use in HVHZ: No f1153S_3 83 II 08-Q1443n.I2df Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8' x 84". Max mullion fU5353 R AE 512067B.od( span - 83" Created by Independent Third Party: Yes 15353.9 CM-18532 y-` rHorizontal Aluminum Mullion Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size - 52-1/8" x 84". Max mullion span - 156-3/8" 15353.10 CM-18533 ^ -- Limits of Use - -----._ v_----- •— Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". Max mullion span: 83" 153S3.11 ! CM-18S34 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". Max mullion span: 156-3/6'. Installation Instructions IF 3 R3 II nA- l4538.o if Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports j5M-jk)-A_C 5130778,pd Created by Independent Third Party: Yes Vertical Aluminum Mullion Installation Instructions - FL1S353 R3 11 08-014440,pof Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports LI-1 5353JU AE 5120680.P(f Created by Independent Third Parry: Yes Horizontal Aluminum Mullion • - Installation Instructions ELI_ 353 R3 II 08-01454B.pQf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL15353 R3 AE 512078B.1(—df Created by Independent Third Party: Yes Bade MaR Contact u :: 2601 91a1r Stdne RGad- TataL*.SMe FL 32399 Ph* : OSO-487-IBZJ The State of Fiddle is an AJVEEO employer. l ooydoet 2007-2011 state of Floma.:: g pr ty scetlment :: [ S v state 01 ;; eme Under Florida taw, emal addresses are pubic records. If you do not want your e-mal address released it response to a public -records request, do not send etactronic mall to this entity. Instead, contact the Office by phone or by traditional mat If you have any questions, please contact 850.487. t 39S. •Pursuant to Section 4SS.27S(1), Florida Statutes, effective October 1, 2012, hcertees acensed under Chapter 45S. F.S. must provide the Department with an emal address r they have one. The emal6 provided may be used for official communication with the acertsee. however emal addresses are public record. r you do not wish to supply a personal address, please provide the Department with an emal address which can be made avalable to the public. To determine r you are a licensee under Chapter 455, F.S., please clerk luau. Product Approval Aapts: ac=— Credit Card Safe 3 of 3 4/13/2018, 7:26 AM NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED IO COMPLY WITS REQUIREMENTS OF THE FLORIDA BUILDING CODE 2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE FRAMING IS THE RESPONSIBILITY OF THE ARCHRfC7 OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULA71ONS 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL 6) SINGLE WINDOWS TO BE MULLED APE NOT LIMITED TO THOSE SHOWN IN THIS DPAWING. WINDOWS MUST BE MANUFACTURED EY MI WINDOWS AND DOORS. INC. 7) DESIGN PRESSURE OF JULLED UNIT SHALL BE CONTROLLED BY TrIE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW OR DOOR UNIT. 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. 9) MULLION VERTICAL INSTALLATION IS SHOWN. MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOi EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT. DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REOUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT 10 BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT IHE INTERSEC71ON OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RAIING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH = W1 + W2 2 Rn+sora DESCR IIDN DN1E AAPROVCD P.LVF_ED INSTALLATION DETAILS 06/10/15 RL REVISED ANCHORING NOTES R INSTL DE1. 06/07/0 IRL ANCHORING NOTES: 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8' MINIMUM EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 2) FOR ANCHORING INTO CONCRETE USE 1/4" ELCO ULTRCON TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT WITH 1' MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 3) FOR ANCHORING INTO METAL USE #10 SMS OR SELF DRILLING SCREW WIFH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 4) ALL FASTENERS TO BE CORROSION RESISTANT. 5) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE - MINIMUM COMPRESSIVE STRENGTh OF 3.200 PSI. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR GREATER). D. METAL STRUCTURE -STEEL 18GA (.048') FY=33KSI/FU-52KSI OR ALUMINUM 6063-75 FU=30KSI .062' ThICK MINIMUM. 6) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS 6" FROM EACH MULLION END AND 12' MAX. O.C. THEREAFTER. STAGGER SCREWS AT EACH WINDOW. TABLE OF CONTENTS 7 NO. DESCRIPTION 1 NOTES 2 CONFIGURATIONS AND DP CHART 3 INSTALLATION DETAILS A COMPONENTS MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 - VERTICAL MULLION 63" MULLION SPAN GENERAL NOTES OMAN• DNG No. V.L. 1 08-01439 SCALE NTS JDArL 01/11/12 1 S"LR 1 OF 4 L ROSERTT) LOADS P E. — — tW WDODFORO AD LEIN SVILLE. NC 270M A3&688. W dbffasokiwavamm SIGNED: 100.312017 1R i I`107j'/ 41 E NY6' '4Lp 0 51 *= pSEE OF ; e4, c2ORIOP:t, 2 NIIIIIIN"" Luis R. Lomas P.E. FL No.: 6251A t07 3/8' COMBINED \vIDTH r- WI --{ W2 83' FRAME HEIGHT WINDOW WINDOW MULLION SPAN) 107 3/8' T OMBINED WIDTH r W1W2 T- - 83' LW FRAMEHEIGHT WINDOW MULLION SPAN) if j tG7 3/8" COMBINED WIDTH wt - I I-- w2 83' WINDOW FRAME HEIGHT WIN LH MULLIONJ SPAN) I-- W 1 J I- W2 t07 3/8' 0COMWIDTHDeshmPressure retina s Mullion nfn Tributary 18. 13 25.50 width 30. 00 42.00 in) 4A00 I SZ13 25.00 120.0 12D.0 120.0 120.0 120.0 120.0 37.38 120.0 120.0 120.0 120.0 12 M 0 120. 0 49.03 120.0 98.3 81.2 769 75.2 75.1 62.W 71.0 W-2 39.7 35.9 33.4 32.3 6b63 59. 6 43.7 33,0 29.6 27.4 26.3 12.00 44.9 32.7 24.4 21.8 19.9 1%0 8t.001 28L 1 20.3 LARGE AND SMALL MISSILE IMPACT, LEVEL A WIND ZONE 3 DIMENSIONS IN CHAAT ARE FRAME DIMENSIONS AND DO NOT INCLUDE FLANGE. 107 3/ 8" COMBINED WIDTH W 1 -- I-- w2 aY FRAME L I.Dow HEIGHT MULLION SPAN) FI-- 107 3/ 8" I COMBINED WIDTH III-- W1 11 \Y2 83 / WINDOW H FRAMEHEIGHT( MULLIONSPj)Ll IL- I-- w t 3- w2 IIF-- 107 3/8" COMBINED WIDTH ff I ILLY I DESCRAIDN I DAIL I APPRa(D A REYSED INSTALLATION DETAILS 06/10/15 R.L. I 8 REVISEDANCHORINGNOTESkINSTLDET. 06/07/17 R.I. 3/8' COMBINED WIDTH/ FWI107 W2/ 83' j J WINDOW J FRAME HEIGHT WINDO/ j WINDOW MULLION N) APPROVED CONFIGURATIONS MULTIPLE UNITS MAYBE MULLED TOGMER AS LONG AS COMBINED WIDTH DOES NOT EXCEED 107 "'AS SHOWN HEREIN Desian Dmssure ratin with rebar Mullion open ( In) T 18. 13 2&50P38 butarV width 42.00 In 48. 00 52.13 2S.W 120.0 120.0 120.0 120.0 120.0 37.38 120.0 120.0 120.0 120.0 120.0 49.63 120.0 98.3 76.9 75.2 751 02.00 95.2 70.0 461 44.8 434 65.63 80.0 58.6 39.7 36.7 353 72.00 60.3 43.9 29.2 26.7 25.5 84.00 37.7 27.3 20.1 17.7 16.0 15.1 LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT INCLUDE FLANGE. W 1 ' I I-- Yl2 107 3/ 8" COMBINED WIDTH MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 - VERTICAL MULLION 83" MULLION SPAN APPROVED CONFIGURATIONS AND RATING CHARTS DRUM. trAt ND. V.L. 08-01439 WALE NTS 1DkTc 01/11/12 -r2 OF L R08ERTO ICU" RE 1431 N' OODFDRO RD LE"VlltE. AV 27= 43444C48w 'amrast3mm m wn SIGNED: 1011312017 GEIVS 9• I* ; STATEE OF ,•i& c R1 P i rrs/ 01VAIL \\ Luis R. Lomos P.E. FL No.: 62514 1" MIN EDGE DISTANCE MASONRY/CONCRETE BY OTHERS i 1 1/4" MIN EMBEDMENT arvaloNi o[sCRmllo" LATE I APPRUCK 3EVISED INSTALLATION DETAILS 06/10/15 R.L. REVISED ANCHORING NOTES & INSTL DET. 05/07/17 R L. 1/4• ELCO ULTRACON TAFCON M7000022 CLIP SECT5796 CUP 10 SMS OR REBAR OPTIONAL ; ;I SSECL4FEWDRILLING SECT5764 MULLION M7000022 CLIP 10 WOOD SCREW 1 3/8• MIN EMBEDMENT 1/2 MIN, EDGE DISTANCE VERTICAL CROSS SECTION MASONRY)OONCRETE AND WOOD FRAMING INSTALLA7I01V NOTE: CLIPS MY BE USED IN MASONRY/CONCRETE OR WOOD FRAMING SUBSTRATE. WOOD FRAMING/ 2X BUCK BY OTHERS M-IAL 1/2' MIN. L STRUCTURE EDGE BY OTHERS DISTANCE VERTICAL CROSS SECTION METAL INSTALLATION SIGNED: 1011312017 MIWINDOWS DOORS, LoMA0650WESTMARKETSTREETJ\611 111I GRATZ, PA 17030-0370 GENSF •it 5 * = 4.TIAT 5764 — VERTICAL MULLION fiTA MULLION SPAN INSTALLATION DETAILS 7OF : t i"FS;l0R10" GR sK ONG NO. RLv V. L. 08 01439 B 4i/S/ONA11`` Luis R. Lomas P.E. is No.: 62514 LA1ENTS 01/11/12 3 OF 4 L ROBERTO LOU4S P.E. 11,T2 Kl000fm RD LEWSNLLE NC 27027 XWWS@4bnmp"*m F-- 2.140' -1I T 1.tI SECT5764 MULLION ALUMINUM 60DiT3.125'TH1CK I RF-185 2 REBAR 16 GA (.062) GALVANIZED STEEL NOTES: 1. CLIPS MAY BE USED IN AVLSONRY/CONCRETE OR WOOD FRAMING SUBSTRATE. 2 FOR WOOD & METAL INSTALLATION USE ALL FOUR ANCHOR LOCATIONS. 3. FOR CONCRETE INSTALLATION USE 2 ANCHOR LOCATIONS ONLY WITH 3 1/4- SEPARATION BETWEEN ANCHORS. 3 281' — 1.375" 0.625' -1 F L_ 3.250' 0 64 3' 4.000' O MT000022 CLIP 16GA (.0637 GALVAMZED STEEL SEE NOTE 2 A 3. THIS SHEET. 3.750' 2.189" 1. 0' 0.375' 1 I 2x 00.210• 1 D1.562" SECT5796 CLIP FOR WOOD FRAMING WSTALLA770N ALUMINUM 6063-T3.12S THICK REV610Ns DESCRLiTID.V I DATE APPR-m- REVISED INSTALLATION DETAILS 06/10/15 R.I. REVISED ANCHORING NOTES h INSTL DET 06/07/17 1 RL. 3.750' 1.0DO' 0. 0 2 0.843- 2 B75' SECT5796 CLIP ` 2x 00.210" FOR CONCRETE INSTALLATION ALUMINUM 6=-T5.125' 1H/CK NI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ. PA 17030-0370 5764 - VERTICAL MULLION 83" MULLION SPAN COMPONENTS 0144": D r NO I REV V.L. 08-01439 B Sqc NTS 01r 01/11/12 1 S"Lrl4 OF 4 L ROBERTO.101W P.E 14M NOODFORD AD LENTSVRLF, NC 2W 434-M-WO Aw=SV w*pemm SIGNED: 1011312017 5111 1 I I C/0 7j//'/ v •GENS 9,' DT E OF ;' JoftjOP •' M' i///Sjs pNAj1 tvG\. Luis R. Lomas P.E. FL No.: 62514 Florida Building Code Online https://www.floridabu i id i ng.org/pr/pr_app_dtl.aspx?param=wGE V X... Professional Regulation rr amrill SCIS Home I too to I user Reoisteation I Hot Topics I submit surcharge i Stats a Facts I publications I FSC Staff I acts Ste Map Links Search F rida t&Product Approval usenn: Pubes user ProdIKt.Apploval,l_tenu > P1ttSJuCt.er-ARD O1Son Search > Aaakaumjkt > AppRotion tDetaR FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL13223-R4 Revision 2017 Approved James Hardie Building Products, Inc. 26300 La Alameda Ste. 250 Mission Viejo, CA 92691 909)349-2927 pingsheng.zhu@jameshardie.com Pingsheng Zhu pingsheng.zhu@jameshardle.com Pingsheng Zhu 10901 Elm Ave. Fontana, CA 92337 909)349-2927 pingsheng.zhu@jameshardle.com Pingsheng Zhu 10901 Elm Ave. Fontana, CA 92337 909) 349-2927 pingsheng.zhu@jameshardie.com Panel Walls Siding Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Ronald I. Ogawa PE-24121 Intertek Testing Services NA, Inc. - QA Entity 12/31/2020 John Southard, P.E. Validation Checklist - Hardcopy Received FLJ3_Z3 qA COI fjlp - Certificate of Indeoendence.pdf Standard Year ASTM C1186 2007 ASTM E330 2002 I of 3 4/13/2018, 7:29 AM Florida Building Code Online https://www.Floridabtiilding.org/pr/pr app—dtl.aspx?param=YGEVX... Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Florida Licensed Professional Engineer or Architect FL1j2_ 3 R4 quly 1110-2,692E-17 ASTM C1186 egulvalencv od Method 1 Option D 08/09/2017 08/25/2017 08/28/2017 10/10/2017 Summary of Products FL Model, Number or Name 13223.1 I Cempanel Siding — 1 Limits of Use '_— _—•- -- -----_ Approved for use in HVHZ: Yes j Approved for use outside HVHZ: Yes SImpact Resistant: Yes Design Pressure: N/A Other: For use Inside a HVHZ Install In accordance with NOA 17-0406.06 HardiePanel Siding^ Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: For use Inside a HVHZ Install In accordance with NOA 17-0406.06 i 13223.3 Prevail Panel Siding i Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use Inside a HVHZ Install in accordance with NOA 17-0406.06 Description fiber -cement panel siding Installation Instructions -- — FL13223 R4 It cemp,Apel-Installatlon.pdf FL] 32Z3 R4 II NO 17-Q40.6.06,pd[ FL13223 R4 It RIP 2689-17_ panel to Furring.gjf FL3 223 R4 If RIO-2686-17 Panel Wood Metal Frame,pdf Verified By: Ronald 1. Ogawa 24121 Created by Independent Third Party: No Evaluation Reports fL132pdf FL13223 R4 AE 111 2689-17 Panel to Furrina.pdf FL1. 3223 R4 AE 11I0-2686-17 Panel Wood Metal Frame.pdf Created by Independent Third Party: Yes fiber - cement panel siding Installation Instructions —"_--_ FL13223 _ R4_ It HardleEp even l-Installation.pdf FL13223 R4 II NOA 17-0406&6.pdf FL13223 114-11 RIO 2689-17 Pan@I to Fu ing:pllf FL13223 R4 It RIO-2686-17 Panel Wood Mgtpl Frame.pdf Verified By: Ronald I. Ogawa 24121 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06.odf FL13223 R4 AE RIO 289-17 Panel to Furrino.odf FL13223 R4 AE RIO-2686-17 Panel Wood Metal Framg,pdf Created by Independent Third Party: Yes fiber -cement panel siding— - Installation Instructions -- — - — FL13223 R4 11 NOA 17-0406.06,pdf FL13223 R4 If Prevail -Panel -Installation.gdf FL13223 R4_ ll Rt0 2689-17 Panel to furrino df FL13223 R4 II RIO-2686-17 Panel Wood Metal Frame.pdf verified By: Ronald 1. Ogawa 24121 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06.gdf FI-0223 R4 AE RIO 2689-17 Panel to Furrina,p fff FL13223 R4 AE RIO-26Q6j Panel Wood Metal Frame.pdf Created by Independent Third Party Yes — back Nattt contact us :: 2601 gf 5ton Road.SalWhassee.F13234.4 Prone: aso-+al-tez+ The state of Florlda Is an AA/EEO employer. [onydaht 1no7-2111+ State of flarlda.:: ejheA w StateM M :: A=3jb atyjtatement ::Refund Statement 2 of 3 4/ l3/2018, '7:29 AM Florida Building Code Online https://www.tloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVX..; Under Fonda law, email addresses are pubic records. 9 you do not want your e•mal address released In response to a public-recoNs request, do not send electronic mail to this entity. Irtstwd, contact the office by phone or by traditional maL If you have any questions, please contact 8S0.487.1395. 'Pursuant to Section 4SS.27S(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emals provided may be used for offc0l communication with the licensee. However emal addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To detennbie If you are a licensee under Chapter 4SS, F.S, pease OiCk ftM. Product Approval Accepts: RM iGNc Credit Card Safe 3 of3 4/13/2018, 7:29 AM Florida Product Approval HardiePanel® Siding For use inside HVHZ: o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami -Dade County Florida NOA 17- 0406.06. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. For use outside of HVHZ, o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Reports RIO-2686-17 or RIO-2689-17. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. 0 HardiePanel"Aff'.0. Vertical Siding JamesHardle INSTALLATION REQUIREMENTS RMEN11AL SINGLE FAMILY ONLYPRIMEDU i3 COLORPLUSa' EFFECTIVE SEPTEMBER 2013 RM PRODUCTS Ylsit y}ww.iamr>sttardtu,Nwn r the most recerd version. SMOOTH - CEDARMILLO • SELECT SIERRA 8 -STUCCO IMPORTANT: FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY. BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS INSTALLATION OF HZ1OTm PRODUCTS OUTSIDE AN HZ100 LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONE APPLIES TO YOUR LOCATION, VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343 STORAGE & HANDLING: Store flat and keep dry and covered prior to installation. Installing siding wet or saturated may result in shrinkage at butt joints. Carry planks on edge. Protect edges and corners from breakage. James Hardie is not responsible for damage caused by Improper storage and handling of the product. — CUTTING INSTRUCTIONS OUm00nS INDOORS 1. Poetiion cutting station so mat wind will 1>bw dust away from user 1. Cut only using score and snap, or shears (manual, electric or pneumatic). and others in VON nnpp area. 2. Position cutting station in well-venUiated area 2. Use one of the Idbwing ntetitOds a Best L Soom and sratw I. Shears (manual, electric or pneumatC) - NEVER use a power saw Indoors b. Better. I. Oust reducing ehaAar saw equipped v fth a - NEVER use a dnclar saw blade that does not the HartEcBlade saw blade trademark Harde8lada' saw blade and i A vacuum extraction - NEVER dry sweep — use wet suppression or HEPA Vacuum c. Good: 1. Oust educing circular saw with a Hardie8lade saw Mode only use for law to moderate cutting) Important Note: For mammwm protection Qavesl respirable dust pnoducuoro, James Hai feounmrads always using hest' -level cfI&p methods where feasible. spiramrs can be used in conjunction with afore culling practices to further reduce dust elposures Additional wposure Information Is available euom to help you delenmhe the most appropriate rutting method for you jab requirements. II ooncem sbl exists about exposure levels or you the above practices, you should always consult a qualified Indtstfal hygienist or contact James Hardie for further Information. sxmlae GENERAL REQUIREMENTS: These instn)clions to be used for residential single family installation only. For Commercial / Multi -Family installation requirements go to www.JamesHardleCommerclal.00m HardiePanel• vertical siding can be installed Doer traced wood or steel studs spaced a maldmum of 24" o.c. See genemal fastening requirements. Irregularities in framing and Sheathing can minor through the finished application. James Hardie recommends installing HardiePanel on a capillary break (raincxeen/ftarirng) as a best practice. Information on Installing James Hardie products over foam can be located in JH Tech Bulletin 19 at wow. lamehardle.com A water -resistive barrier is required in accordance with local building code requirements. The water -resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration. James Hardie does manufacture HardieWrap® Weather Barrier, a Iron -woven non -perforated housewrapl, which compiles with building code requirements. When Installing James Hardie products all clearance details In figs. 5,6,7,8,9,10&11 must be followed. Adjacent finished grade must slope away from the building In accordance with local building codes - typically a minimum of 6" in the first 10'. Do not Install James Hardie products, such that they may remain in contact with standing water. HardiePanel vertical siding may be installed on vertical wall applications only. 00 NOT use HardiePanel vertical sidingg In Fascia or Trim applications. Some application are not suitable for olorPlus. Refer to ColorPlus section pa a 3. 00 NOT use stain, oil/alkyd base paint or powder coating on James Hardie®Products. For larger projects, including commercial and multi -family projects, where the span of the wall is significant In length, the designer and/or architect should take Into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be found in the Technical Bulletin 8 "Expansion Characteristics* at www.JamesHardie.com. INSTALLATION: Joint Treatment Fastener Requirements • Vertical Joints - Install panels in moderate contact (fig. 1), alternativelyPositionfasteners3/8" from panel edges and no closer than 2" away from corners. Do not nail Into corners. joints may also be covered with battens, PVC or metal jointers or HardiePanel Vertical Siding Installation caulked (Not applicable to ColorPlus Finish) (fig. 2). Framing must be provided at horizontal and vertical edges for nailing. •Horizontal Joints Provide 2-flashing at all horizontal joints (fig. 3). HardiePanel vertical siding must be joined on stud. Figure 2 Figure 3 waterraslstive barrier water -resistive banter Double stud may be required to maintain minimum edge 4 stud / water-reslstle water -resistive nailing distances. f 2 `4aNd tarry barrier Figure 1 s,u water -resistive barrier sheathing HardlePen o o vertical Sidi keee nails3183/8 min. l/\ from panel edges moderate contact keep fasteners 2- away from comers Batten Joint "H" Joint water -resistive barrier ft 4 stud leave appropriate gap between panels• then caulk' Caulk Joint Not applicable to C4WIus• Fink ) Apply caulk in accordance with caulk manufacturer's written application Instntctlom. For additional Information on HardleWran'"' Weather Barrier, consult James Hardie at 1.866-4Hardle or www.hardiewmo.com rD.7orpanel .•—upper panel autk 1/a' gap Oo not 1/4" Stop 2 flashBg f Z-lashing's decorative r band board laver lower panel pallet Recommendation: When Installing sierra 8, provide a double stud at panel joints to avoid "Ting truotgh proo'wes. Figure 4 WARNING: AVOID BREATHING SILICA OUST ranks l lard& produos contain req*aMe crystallite sllkb, vfth B ktom to ate Stated California to cause cancer and Is eaWdered by IARC end NIOSH robe a cause of CWW tmm same oMupadonal sauttses. IkeetNrg heemrnmLF' Uona Itaoercrs hb slip Oahg cleanup, use H A aanms a wot deatarp mdtnds - nr ver Ay sxeeP. Fa lusher Intamatbn. refer to our Irtstalheaon ImSirucbac and Material Safely Oats Shcd available at www jamoabaude. com or by calling I •e00.911ARDIE (1.800-942-7343). FAILURE TO ADHERE To OUR WARNINGS, MSOS, AND INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL eL W OR DEATH. lxwn HS1236 - P1/ 3 1/13 N >o• CLEARANCES Install siding and trim products in Maintain a minimum 1" Maintain a minimum 1" - 2" clearance At the juncture of the roof and vertical Maintain a 1/4' compliance with local building code - 2" clearance between between James Hardie products surfaces, flashing and counterflashing clearance between requirements for clearance between James Hardie® and decking material. shall be installed per the roofing the bottom of James manufacturer's instructions. Provide a Hardie products andthebottomedgeofthesidingandproductsandpaths, Figure 7 minimum 1 "- 2" clearance between horizontal flashing. the adjacent finished grade. steps and driveways. Figure 5 geld Figure 6 eor"aw 6' min. I rwndstan Maintain a minimum 1" gap between gutter end caps and siding 8 trim. Figure 9 gutter and end cep On not bridge floors vrith HardiePane19 siding. Horizontal joints should akvays be created belvreen floors (rig.10). water - Resistive i Ramer i Fremirq Figure 10 Horizontal - Flowing Trim n sheathing 4 f =a HarelePanel° a BLOCKED PENETRATIONS .. Penetrations such as hose bibs and holes 1 36" or larger such as dryer vents should have a block of trim around point of penetration. GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot -dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie products near the ocean, large bodies of water, or in very humid climates. Consult applicable product evaluation or listing for correct fastener type and placement to achieve specific design wind loads. NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable compliance documentation. Drive fasteners perpendicular to siding and framing. Fastener heads should fit snug against siding (no air space). (fig. A) Do not over -drive nail heads or drive nails at an angle. If nail is countersunk, fill nail hole and add a nail. (fig. B) For wood framing, under driven nails should be hit flush to the plank with a hammer (for steel framing, remove and replace naiq. NOTE: Whenever a structural member Is present, HardiePlank should be fastened with even spacing to the structural member. The tables allowing direct to OSB orplywood should only be used when traditional framing is not available. Do not use aluminum fasteners, staples, or clipped head nails. Snug Flush Countersunk, fill 8 add nail Figure A Figure B do not under drive nails oo ror STAPLE the roofing and the bottom edge of the Do not caulk gap. siding and trim. Refer to fig. 3 on Figure 8 page 1. r I 1••Ymin KICKOUT FLASHING Because of the volume of water that can pour down a sloped roof, one of the most critical flashing details occurs where a roof intersects a sidewall. The roof must be flashed with step flashing. Where the roof terminates, install a kickout to deflect water away from the siding. It Is best to install a self -adhering membrane on the wall before the subfascia and trim boards are nailed in place, and then come back to Install Hie kickout. Figure 11, Kickout Flashing To prevent water from dumping behind the siding and the end of the roof intersection, install a "kickout" as required by IRC code R905.2.8.3 : ".. flashing shall be a min. of 4" high and 4' wide." James Hardie recommends the kickout be angled between 100e -110• to maximize water deflection Figur PNEUMATIC FASTENING James Hardie products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening Is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachment on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive under driven nails snug with a smooth faced hammer - Does not apply for installation to steel framing). HS1236 - P2/3 8/13 AZ >o. CAULKING For best results use an Elaslomeric Joint Sealant complying with ASTM C920 Grade NS, Class 25 or higher or a latex Joint Sealant complying with ASTM C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note: OS10jad as well as some other caulking manufacturers do not allow tooling. 00 NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section CUT EDGE TREATMENT PAINTING Caulk, paint or prime all field cut edges. DO NOT use stain, oiValkyd base paint, or powder coating on James Hardie® Products. James Hardie products James Hardie touch-up kits are required must be painted within 180 days for primed product and 90 days for unprimed.100% acrylic topcoats are to touch-up ColorPlus products. recommended. Do not paint when wet. For application rates refer to paint manufacturers specifications. Back -rolling Is recommended if the siding is sprayed. COLORPLUS• TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE Care should be taken when handling and cutting James Hardie® ColorPlus® products. During installation use a wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product, then rinse with a garden hose. Touch up nicks, scrapes and nail heads using the ColorPlue Technology touch-up applicator. Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with new HardiePanel4° siding with ColorPlus Technology. Laminate sheet must be removed immediately after installation of each course. Terminate non -factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus® product dealer. Treat all other non -factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer. Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third parry touch-up paints or paints used as touch-up that are not James Hardie touch-up, will not be covered under the James Hardie ColorPlus Limited Finish Warranty. The following outlines the recommended applications for ColorPlus and Primed panels. Not all designs will be suitable for every application: Exposed fasteners or battens is the recommended application for ColorPlus panel products Do not use touch-up over fastener heads for smooth ColorPlus products - primed panel recommended For ColorPlus panel applications that require fasteners in the field, it is acceptable to use touch-up over fasteners for Cedarrnill and Stucco panel only, but correct touch-up application is important. Some colors may show touch-up when applied over fasteners. Trim is recommended to cover joints when appropriate. PAINTING JAMES HARDIE• SIDING AND TRIM PRODUCTS WITH COLORPLUS• TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: Ensure the surface is clean, dry, and free of any dust, dirt, or mildew Repriming is normally not necessary 100% acrylic topcoats are recommended DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie® Products Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature RECOGNITION: In axadance vdth ICC-ES Evaluation Report ESR-1844, HardGeParrel® vertical siding Is recognized as a suitable alternate to that sperllled rr the 2006.2009, b 2012 kdematiorol Raddemal Code far Ono -and Two-family Urelrr.ps and the 2006, 2009. 3 2012 International Building Code. HardePand vertical skBrq Is also recognized tar application In the (atbwlrg: aty, of Los Angeles Research Report No. 24862. State of Flartda lis ft F14889, Dade county. Florida NOA No. 02-0729.02. Us Dept. of HUD Materials Release 1263c. Texas Oepanmenl of Insurance Product Evaluation EC-23, city of New York MEA 223-93A1, and Calramia GSA PA•019. rnese tlwinerm shoule afro be cons fled for adddiorml Informom eonceaft the atlmbtltty of tide product tar speclac applications. 2013 Jaynes Hardie euilding Products. Ali rights reserved. p TM, SM, and ® denote trademarks or registered trademarks of Additional Installation Information, HJamesHardleTechnologyLimitedCsisaregisteredWarranties, and Warnings are available at JamesHardle trademark of James Hardie Technology Umfted. www.jameshardie.com HS1236 - P3/3 6/13 Florida Building Code Online https:Hwww.floridabuilding.org/pr/pr_appjtl.aspx?param=wGEVX... ti Business a -Regulation SCtS Home I Log to I User Regtstratbn I Not Topics Submt Stmliarge i Stats 8 Facts I Publications I FBC Staff I SCIS Ste Map I Links Search i F da r Product Approval USER: PLfilk User ftdugLmoinvat Memi > Prnnuct or ADCMA LVn Search > BQplsgtlon ust > Application Ontall FL # FL12194-R7 Application 'type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Aluminum Coils, Inc. Address/Phone/Email 5001 West Knox Street Tampa, FL 33634 813)249-9743 grahman@aluminumcoilsinc.com Authorized Signature Gareth Rahman grahman@aluminumcolisinc.com Technical Representative Paul Frost Address/Phone/Email 5001 West Knox Street Tampa, FL 33634 813)249-9742 PFrost@aiumlnumcoilsinc.com Quality Assurance Representative Address/Phone/Email Category Panel Walls Subcategory Soffits Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Flonda Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 06/19/2020 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL12194 R7 COI ALCA 2017 FBC Evaluation R_gportQ4 Tg Soffits Final,QQf Standard AAMA 1402 Year 2009 1 of2 4/13/2018, 7:37 AM Florida Building Code Online https:Hwww. floridabu ilding.org/pr/pr_app_dtl.aspx?parain=wG GV X... Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 12/15/2017 12/15/2017 12/20/2017 02/13/2018 Summary of Products - FL!._ Model, Number or Name 112194.1 -- Alumunum Coils Aluminum Soffit Limits of Use Approved for use in HVHZ: No i Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +80/-90 Other: See Evaluation Report for limits of use. Description Aluminum soffit panels --- Installation Instructions FL12194 R7 II ALCIS001.4 2017 FBC Evaluation Repysr 4 T4 Soffits Flnal.odf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL12194 R7 AE ALC1S001.4 2017 FBC Evaluation Repot Q4 T4 Soffits Flnal.pd_f Created by Independent Third Party: Yes I CoildrL:: Bso•497-182+ The State of Florida Is an AA/WOemployer. LWacy slatealeot :: ACMSSLBdN 51UeM9= :: a %aterMM Under Florida law, email addresses are pubic records. If you do not want your a-mal address released In response to a public -records request, do not send electronic mad to this entity. Instead, contact the office by phone or by tradRonal mail If you have arty questions, please comas BS0.487.139S. •pursuant to Section 4SS. 27S(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4SS, F.S. must provide the Department with an email address If they have one. The emalts provided may be used for offkal communication with the acensee. However email addresses are pubic recoN. ff you do not wish to Supply a Personal address, please provide the Department with an email address which can be made avaWble to the pubic. To determine If you are a licensee under Chapter 4SS, F.S., please click hgM. product Approval Aooepts- . itrer Credit Card Safe 2 of 2 4/13/2018, 7:37 AM CREEK TECHNICAL SERVICES, LLC Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 6r" EDITION (2017) Manufacturer: ALUMINUM COILS, INC. Issued December 14, 2017 5001 West Knox Street Tampa, FL 33634 813) 249-9743 www.afuminumcoilsinc.com Manufacturing: Tampa, FL Quality Assurance: PRI Construction Materials Technologies (QUA9110) SCOPE Category: Panel Walls Subcategory: Soffits Code Sections: 1404.5.1, 1709.10 Properties: Wind Resistance REFERENCES Enti& Renort No. Standard Year Certified Testing Laboratories (TST1577) CTLA 1847W AAMA 1402 2009 Certified Testing Laboratories (TST1577) CTLA 2076W AAMA 1402 2009 PRI Construction Materials Technologies (TST5878) ACIX-003-02-01 AAMA 1402 2009 PRI Construction Materials Technologies (TST5878) ACIX-003-02-02 AAMA 1402 2009 PRI Construction Materials Technologies (TST5878) ACIX-008-02-01 AAMA 1402 2009 LIMITATIONS 1. This report is not for use in the HVHZ. 2. Design wind loads shall be determined in accordance with FBC Section 1609. 3. Soffits shall be labeled in accordance with FBC Section 1709.10. 4. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5. Installations shall meet the minimum ventilation requirements of FBC section 1203.2. 6. Field fastener withdrawal may be required by the AHJ for confirmation of existing substrates. All data shall be reviewed by a qualified design professional to ensure the fastener withdrawal meets or exceeds the minimum load resistance for the project requirements. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. ALC15001.4 FL12194-R7 Pane 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 C R E E K ALUMINUM COILS, INC Soffits TECHNICAL SERVICES, LLC PRODUCT DESCRIPTIONS 318" F-Channel Preformed nominal 0.016-inch thick, 3105 H-14 aluminum F-channel. See Appendix D for dimension drawings. 318" J-Channel Preformed nominal 0.016-inch thick, 3105 H-14 aluminum J-channel. See Appendix D for dimension drawings. Fascia Preformed nominal 0.019-inch thick, 3105 H-14 aluminum fascia. See Appendix D for dimension drawings. 16" 04 Soffit Preformed nominal 0.01354nch thick, 3105 H-14 aluminum soffrt2panels provided in 16- inch sections. The reported net free ventilation areas are 22.3 in /lin.ft. for the 'full vent' configuration and 11.1 in2/lin.ft. and for the 'center vent' configuration. See Appendix D for dimension drawings. w..ZZ..•.; 1 Z " ZZ Z Z Nz?i::,. W FULL VENT 12" T4 Soffit Preformed nominal 0.0135-inch thick, 3105 H-14 aluminum soffit Zpanels provided in 12- inch sections. The reported net free ventilation areas are 12.5 in /lin.ft. for the 'full vent' configuration and 4.2 inZflin.ft. for the 'center vent' configuration. See Appendix D for dimension drawings. ALC15001.4 FL12194-R7 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT ALUMINUM COILS, INC Soffits The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 60' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. 11111IIIl11JI'lFtYR. p . Ri E N SF No 74021 XZ 3 STATE OF '•Q+ CERTIFICATION OF INDEPENDENCE 2017.12.14 16:21:34 051001 Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A —Approved Systems (11 pages) 2) APPENDIX B — Installation Drawings (19 pages) 3) APPENDIX C — Design Wind Loads(4 pages) 4) APPENDIX D — Dimension Drawings (4 pages) ALC15001.4 FL12194-R7 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC APPROVED SYSTEMS ALUMINUM COILS, INC Soffits Appendix A The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressures (MDP) were calculated using a 1.5:1 margin of safety per FBC Section 1404.5.1. 2. Refer to Lt mTAnoNs and sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION sectjon of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on -center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system. 5. Unless otherwise specified, the Wood substrate shall be minimum No. 2 SPF (S.G. = 0.42) 2x lumber. Substrate attachment shall be designed by others in accordance with FBC requirements to meet the minimum design requirements for the project. 6. Unless otherwise specified, the Masonry substrate shall conform to ASTM C 90. Substrate attachment shall be designed by others in accordance with FBC requirements to meet the minimum design requirements for the project. 7 Typical fastening details are as follows: a. 12" T4 Soffit— 12-inch o.c. Fastener Fastener Locaati onn— Location b. 12' T4 Soffit — 4-inch o.c. Fastener Fastener Fastener Fastener Loc tion Location Lotion Location c. 16' 04 Soffit —16-inch o.c. Fastener Fastener Location Location ALC15001.4 FL12194-R7 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC d. 16' 04 Soffit— 8-inch o.c. Fastener Lotion Fastener Fastener Loction ALUMINUM COILS, INC Soffits Approved System Numbers and Definitions 10.5JJa# Approved Systems for 10.5-inch Soffit Span with J-Channel at Wall and Eave 12L4 Approved Systems for 124nch Soffit Span with F-Channel and Fascia Ca 12.14 Approved Systems for 12-inch Soffit Span with J-Channel and Fascia Ca Rul Approved Systems for 124nch Soffit Span with J-Channel at Wall and Eave 14.SJJ-# Approved Systems for 14.5-inch Soffit Span with J-Channel at Wall and Eave 16F-# Approved Systems for 164nch Soffit Span with F-Channel and Fascia Ca 16.14 Approved Systems for 164nch Soffit Span with J-Channel and Fascia Ca 16JJ-# Approved Systems for 16-inch Soffit Span with J-Channel at Wall and Eave 22.5JJ Approved Systems for 22.5-inch Soffit Span with J-Channel at Wall and Eave 24F:# Approved Systems for 244nch Soffit Span with F-Channel and Fascia Ca 24J Approved Systems for 244nch Soffit Span with J-Channel and Fascia Ca 4JJl Approved Systems for 244nch Soffit Span with J-Channel at Wall and Eave Appendix A Approved Systems for Maximum 10.6-inch Soffit Span with J-Channel at Wall and Eave Wall Connection Eave Connection System Panel MDP No Width psf) Substrat J-Channel Substrate J-Channel e Attachment Attachment Three (3) 18 ga.1/4-inch crown x 1-inch leg staples in diamond pattern spaced 244nch o.c. securing Three (3) 18 ga.1/44nch crown x 1-inch leg staples in Max. J-Channel to joists; diamond patternspaced 24-inch o.c. securing 10.5JJ-1 16-inch Wood One (1) 18 ga.1/4-Inch crown x 1-inch leg staples Wood J-Channel to joists; 359.8 located in the horizontal leg of the J-Channel spaced One (1) 18 ga.1/4-inch crown x 1-inch leg staples located 12-inch o.c. in the horizontal leg of the J-Channel spaced 12-inch o.c. ALC15001.4 FL12194-R7 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES. LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for Maximum 12-inch Soffit Span with F-Channel and Fascia Cap Wall Connection Eave Connection System Panel MDP No. Width Psi Substrate F-Channel Substrate Panel Attachment Fascia Cap Attachment Attachment Max. One (1) min. 3/84nch head dia. nail, One (1) min. 3/8 x 3/8-inch crown One (1) min. 1 3/44nch long x 0.0724nch dia. x min. 3/16- 12F-1 16-inch Wood min. 1.25-inch embedment spaced Wood staple spaced 16-inch o.c. inch head dia. trim nail 40 24-inch o.c. spaced 364nch o.c. One (1) 14 ga. 5/84nch long T nail or One (1) min. 1 3/44nch long x 12F 2 Max. Masonry 9 ga., min. 5/8-inch long Stub Nail Wood One (1) min. 3/8 x 3/8-inch crown 0.0724nch dia. x min. 3/16- 40 164nch with 3/8-inch diameter head spaced staple spaced 164nch o.c. inch head dia. trim nail 84nch o.c. spaced 364nch o.c. Max. Three (3) min. 3/4-inch x 1/44nch One (1) min 3/4-inch x 1/44nch One (1) min. 1 3/4-inch long x 0.0724nch dia. x min. 1/44nch 48 12F-3 164nch crown staples in diamond pattern Wood crown staple spaced 8-inch o.c. head diatrip nail spaced 48- 64.2 spaced 24-inch o.c. spacedand securing each panel lap inch o.c. One ( 1) 14 ga. 5/8-Inch long T nail or One (1) min 3/4-inch x 1/4-inch One (1) min. 1 3/44nch long x 12F4 Max Masonry 9 ga., min. 5/8-inch long Stub Nail Wood crown staple spaced 8-inch o.c. 0. 0724nch dia. x min. 1/4-inch 48 164nch with 3/8-inch diameter head spaced and securing each panel lap head dia. trip nail spaced 48- 64.2 8-inch o.c. inch o.c. Approved Systems for Maximuml2-inch Soffit Span with J-Channel and Fascia Cap Wall Connection Eave Connection System Panel MDP No. Width Pso Substrate J- Channel Attachment Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Three ( 3) min. 3/4- inch x 1/44nch crown One (1) min. #8 x 1/2-inch One (1) min 3/44nch x One (1) min. 1 3/4-inch long x 12J 1 Max. 16- inch Wood staples in diamond long x 3/8-inch head diameter spaced 164nch o.c. Wood t/ crown staple 0.072- inch dia. x min. 1/4 Inch head dia. trip nail spaced 48- 48 64. 2 patternscrew patternspaced24- connecting soffit to J-channel spaced spaceed 8inch o.c. inch o.c. Inch o. c. ALC15001.4 FL12194-R7 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for Maximum 12-inch Soffit Span with J-Channel at Wall and Eave Wall Connection Eave Connection System Panel MDP No. Width psf) Substrate J-Channel Substrate J-Channel Attachment Attachment Three (3) 18 ga.1/4-inch crown x 1-inch leg staples in Three (3) 18 ga.1/4-4nch crown x 14nch leg staples in diamond pattern spaced 244nch o.c. securing diamond pattern spaced 124nch o.c. securing 12JJ-1 Max. Wood J-Channel to joists; Wood J-Channel to fascia; 70 164nch One (1) 18 ga.1/4-inch crown x 14nch leg staples One (1) 18 ga.1/44nch crown x 1-inch leg staple securing 60 located in the horizontal leg of the J-Channel spaced the nailer of each female lock or spaced 16-inch o.c. 124nch o.c. I I securing each panel lap Approved Systems for 14.5-inch Soffit Span with J-Channel at Wall and Eave Wall Connection Eave Connection System Panel MDP No. Width psi) Substrate J-Channel Substrate J-Channel Attachment Attachment Three (3) 18 ga.1/4-inch crown x 1-inch leg staples in Three (3) 18 ga,1/44nch crown x 14nch leg staples indiamondpatternspaced244ncho.c. securing diamond pattern spaced 244nch o.c securing 14 5JJ-1 Max. 164nch Wood J-Channel to joists; One (1) 18 ga.1/4-inch crown x 14nch leg staples Wood J-Channel to joists; 43.3 located in the horizontal leg of the J-Channel spaced One (1) crown x 14nch leg staples locatedga.1/ leg12-inch o.c. ri ofinthehorizontallegof the J-Channel spaced 12-inch o.c. ALC15001.4 FL12194-R7 4of11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES. LLC ALUMINUM COILS, INC soffits Appendix A Approved Systems for Maximum 16-inch Soffit Span with F-Channel and Fascia Cap Wall Connection Eave Connection System Panel MDP No. Width pso Substrate F-Channel Substrate Panel Attachment Fascia Cap Attachment Attachment One (1)14 ga. 5/8-inch long T nail or One (1) 18 ga. 1/44nch crown x One (1) min. 1.754nch x 0.072-inch diameter 16F-1 Max. Masonry 9 ga., min. 5/8-inch long Stub Nail Wood 1-inch leg staple spaced max. finishing nail with min. 3/16- 253.3 124nch with 3/84nch diameter head spaced flinch o.c. and securing each inch head spaced max. 8-inch o.c. panel lap 12-inch o.c. One (1) 18 ga. 1144nch crown x One (1) min. 1.754nch x Max. Three (3) 18 ga. 1/4-inch crown x 1- 1-inch leg staple spaced max. 0.0724nch diameter 16F-2 12-inch Wood inch leg staples in diamond pattern Wood 44nch ocand securing each finishing nail with min. 3116- 53.3 spaced 16-inch o.c. panel lap inch head spaced 124nch o.c. One ( 1) 14 ga. 5/8-inch long T nail or One (1) min 3/84nch x 3/84nch One (1) min. 1 3/44nch long 16F- 3 Max. Masonry Mason9 ga., min. 5184nch long Stub Nail Wood crown staple spaced 16-inch x 0.072 inch dia. x min. 225.6 with 3/84nch diameter head spaced 3/16-inch head dia. trim nail 8- inch o.c.spaced O. C. 364nch o.c. Max. One ( 1) 3184nchhead dia. nail, min. One (1) min 3/84nch x 3/8-inch One (1) min. 1 3/4-inch long x 0.072 inch dia. x min. 16F4 16- inch Wood 1.25-inch embedment spaced 24- Wood crown staple spaced 164nch 3/ 16-inch head dia. trim nail 325. 6 inch o.c. O.C. spaced 364nch o.c. Max. Three ( 3) min. 3/4-inch x 1/44nch One (1) min 3/44nch x 1/44nch One ( 1) min. 1 3/44nch long x 0.072-inch dia. x min. 1/4- 27 16F- 5 16- inch Wood crown staples in diamond pattern Wood crown staple spaced 84nch o.c. inch head dia. trip nail 36.1 spaced 24-inch o.c. spaced 484nch o.c. One ( 1) 14 ga. 5/84nch long T nail or One (1) 18 ga. 1/44nch crown x One ( 1) min. 1.754nch x 0. 072-inch diameter 16F- 6 Max. Masonry 9 ga., min. 5/8-inch long Stub Nail Wood 1-inch leg staple spaced 4-inch finishing nail with min. 3/16- 243.3 16- inch with 3/84nch diameter head spaced o.c. and securing each panel inch head spaced 84nch o.c. lap 164nch o.c. One ( 1) 18 ga. 1/44nch crown x One ( 1) min. 1.75-inch x Max. Three (3)18 ga.1/4-inch crown x 1- 14nch leg staple spaced 4 inch 0. 0724nch diameter 16F- 7 16- inch Wood inch leg staples in diamond pattern Wood o. c. and securing each panel finishing nail with min. 3/16- 343.3 spaced 164nch o.c. inch head spaced 164nch o.c. ALC15001. 4 FL12194-R7 5of11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for Maximum 16-inch Soffit Span with J-Channel and Fascia Cap Wall Connection Eave Connection System Panel MDP No. Width psf) Substrate J-Channel Substrate Panel Attachment Fascia Cap Attachment Attachment Max. Three (3) min. 3/4-inch x 1/4-inch One (1) min 314-inch x 1/4-inch One (1) min. 1 3/4-inch long x 0.0724nch dia. x 23.5 16J 1 16-inch Wood crown staples in diamond pattern spaced 244nch o.c. Wood crown staple spaced 84nch o.c. min. 1/4-inch head dia. trip 31.4 nail spaced 484nch o.c. Approved Systems for Maximum 164nch Soffit Span with J-Channel at Wall and Eave Wall Connection Eave Connection System Panel MDP No. Width psf) Substrate J-Channel Substrate J-Channel Attachment Attachment Three (3)18 ga.1/44nch crown x 1-inch leg staples in Max. diamond pattern spaced 244nch o.c. securing J-Channel to joists; Three (3) 18 ga.1/4-inch crown x 14nch leg staples in 16JJ-1 164nch Wood One (1)18 ga.1/4-inch crown x 14nch leg staples Wood diamond pattern spaced 84nch o.c. securing t32.7 located in the horizontal leg of the J-Channel spaced J-Channel to fascia 12-inch o.c. Three (3)18 ga.t/44nch crown x 1-inch leg staples in Three (3) 18 ga.1/4-inch crown x 1-inch leg staples in diamond pattern spaced 244nch o.c. securing diamond pattern spaced 12-inch o.c. securing 16JJ-2 Max. Wood J-Channel to joists; Wood J-Channel to fascia; 43.3 164nch One (1)18 ga.1/4-inch crown x 14nch leg staples One (1)18 ga.1/44nch crown x 14nch leg staple securing 33.3 located in the horizontal leg of the J-Channel spaced the nailer of each female lock or spaced 16-inch o.c. 124nch o.c. securing each panel lap ALC15001.4 FL12194-R7 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for Maximum 22.5-inch Soffit Span with J-Channel at Wall and Eave Wall Connection Center Connection Eave Connection System Panel MDP No. Width pso Substrate J-Channel Attachment Panel Attachment Substrate J-Channel Attachment Three (3)18 ga.1/4-inch crown x One (1) 18 ga.1/44nch crown x Three (3) 18 ga.1/4-inch crown 1-inch leg staples in diamond 1-inch leg staple securing the nailer x 1-inch leg staples in diamond pattern spaced 24-inch o.c. of each female lock or spaced 16- pattern spaced 24-inch o.c. 22 5JJ-1 Max. Wood securing J-Channel to joists; inch o.c. securing each panel lap Wood securing J-Channel to joists; 42 1 16-inch One (1) 18 ga.1/4-inch crown x One (1) 18 ga.1/flinch crown x 14nch leg staples located in the One (1) min. 1.754nch x 0.0724nch 14nch leg staples located in the horizontal leg of the J-Channel diameter -finishing nail with min. horizontal leg of the J-Channel spaced 124nch o.c. 3/16-inch head spaced spaced 12-inch o.c. 44nch o.c. Approved Systems for Maximum 24-inch Soffit Span with F-Channel and Fascia Cap Wall Connection Center Connection Eave Connection System Panel MDP No. Width psfl Substrate F-Channel Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga.1/44nch Nominal 1x2 crown x 1-inch leg No.2 SYP staple spaced Three (3) 18 ga.1/4- anchored to 12-inch o c. securing One (1) 18 ga. 1/4- One (1) min. 1.754nch x Max inch crown x 14nch ratter with one each panel lap inch crown x 14nch 0.072-inch diameter 80 24F-1 124nch Wood leg staples in 1) min. 2.25- Wood leg staple spaced 8- finishing nail with min. 90 diamond pattern inch x 7d ring One (1) min. 1.75-inch inch o.c. 3/164nch head spaced spaced 16-inch o.c. shank nail x 0.0724nch diameter 124nch o.c. 24-inch o.c. finishing nail with min. 3/16-inch head spaced 44nch o.c. ALC15001.4 FL12194-R7 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for Maximum 24-inch Soffit Span with F-Channel and Fascia Cap Wall Connection Center Connection Eave Connection System Panel MDP No. Width pso Substrate F-Channel Attachment Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment One (1) 18 ga.1/44nch crown x 1-inch leg Nominal 1)2 staple spaced One (1) min. 1.5- No.2 SYP 12-inch o.c. securing One (1) 18 ga. 1l4- One (1) min. 1.754nch x Max. inch x 11 ga. anchored to each panel lap inch sown x 14nch 0.0724nch diameter 80 24F-2 124nch Wood smooth shank rafter with one Wood leg staple spaced 8- finishing nail with min. 76.6 roofing nail spaced 1) 7d x 2.25- One (1) min. 1.75-inch inch o.c. 3116-inch head spaced 16-inch o.c. inch ring shank x 0.072-inch diameter 124nch o.c. nall 244nch o.c. finishing nail with min. 3/16-inch head spaced 44nch o.c. One (1) 18 ga. 1/4-inch crown x 1-inch leg One (1) 14 ga. 5/8- Nominal 1x2 staple spaced inch long T nail or 9 No.2 SYP 12-inch o.c. securing One (1) 18 ga. 1/4- One (1) min. 1.754nch x Max. ga., min. 5/84nch anchored to each panel lap inch crown x 14nch 0.072-inch diameter 80 24F-3 124nch Masonry long Stub Nail with rafter with one Wood leg staple spaced 8- finishing nail with min. 76.6 3/8-inch diameter 1) 7d x 2.25- One (1) min. 1.754nch inch o.c. 3l16-inch head spaced head spaced 8-inch inch ring shank x 0.0724nch diameter 124nch o.c. O.C. nail 244nch o.c. finishing nail with min. 3/164nch head spaced 44nch o.c. One (1) 18 ga.1/4-inch crown x 14nch leg Nominal 1x2 staple securing the No.2 SYP nailer of each female Three (3) 18 ga.114- anchored to lock or spaced One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max. inch crown x 1-inch rafter with one 16-inch o.c. securing inch crown x 1-inch 0.0724nch diameter 0 24F-4 164nch Wood leg staples in 1) nun. _ each panel lap Wood leg staple spaced 8- finishing nail with min. 60 diamond pattern ininchx7dringr inch o.c. and securing 3/164nch head spaced spaced 164nch o.c. shank nail One (1) min. 1.75-inch each panel lap 164nch o.c. 244nch o.c. x 0.072-inch diameter finishing nail with min. 3/16-inch head spaced 4-inch o.c. ALC15001 4 FL12194-R7 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for Maximum 24-inch Soffit Span with F-Channel and Fascia Cap Wall Connection Center Connection Eave Connection System Panel MDP No. Width pso Substrate F-Channel Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga.1144nch crown x 14nch leg staple securing the Nominal 1x2 nailer of each female One (1) min. 1.5- No 2 SYP lock or spaced One (1) 18 ga. 1/4- One (1) min. 1.754nch x Max. inch x 11 ga. anchored to 16-inch o.c. securing inch crown x 1-inch 0.0724nch diameter 80 24F-5 16 inch Wood smooth shank rafter with one each panel lap Wood leg staple spaced 8- finishing nail with min. SO roofing nail spaced 1) 7d x 2.25- inch o.c. and securing 3/16-inch head spaced 16-inch o.c. inch ring shank One (1) min. 1.754nch each panel lap 164nch o.c. nail 244nch o.c. x 0.0724nch diameter finishing nail with min. 3/164nch head spaced 44nch o.c. One (1) 18 ga.1/44nch crown x 1-inch leg staple securing the One (1) 14 ga. 5/8- Nominal 1x2 nailer of each female inch long T nail or 9 No.2 SYP lock or spaced One (1) 18 ga. 1/4- One (1) min. 1.754nch x Max. ga., min 5/8-inch anchored to 164nch o.c. securing inch crown x 14nch 0.0724nch diameter 80 24F-6 16-inch Masonry long Stub Nail with rafter with one each panel lap Wood leg staple spaced 8- finishing nail with min. 603/8-inch diameter 1) 7d x 2.25- inch o.c. and securing 3/164nch head spaced head spaced 8-inch inch ring shank One (1) min. 1.75-inch each panel lap 164nch o.c. O.C. nail 24-inch o.c. x 0.0724nch diameter finishing nail with min. 31164nch head spaced 44nch o.c. ALC15001.4 FL12194-R7 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC soffits Appendix A Approved Systems for Maximum 24-inch Soffit Span with J-Channel and Fascia Cap Wall Connection Center Connection Eave Connection System Panel MDP No. Width psf) Batten J-Channel Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment Nominal 1x2 No.2 SYP scabbed between rafters with One (1) 18 ga.1/4- one (1) min. 2.25- inch crown x 14nch Nominal 1x2 inch x 7d ring shank leg staple spaced No.2 SYP Three (3)18 nail straight -nailed 124nch o.c. anchored to ga.1l44nch crown through the rafter securing each panel One (1) 18 ga. /.- One (1) min. 1.75-inch Max. rafter with one x 14nch leg into the end of the lap inch crown x t-inch x 0 072-inch diameter 24J-1 124nch 1) min. 2.25- staples in diamond batten or two (2) Wood leg staple spaced finishing nail with min. t60 inch x 7d ring pattern spaced 16- min. 2.25-inch x 7d One (1) min. 1.75- 84nch o.c. 3/16-inch head spaced shank nail inch o.c. ring shank nails toe- inch x 0.0724nch 12-inch o.c. 244nch o.c. nailed on either side diameter finishing of the batten at nail with min. 3116- each batten/rafter inch head spaced intersection. Max. 44nch o.c. rafter spacing is 24-inch o.c. . Nominal 1x2 No.2 SYP scabbed One (1) 18 ga.1/4- between rafters with inch crown x 14nch one (1) min. 2.25- leg staple securing Nominal 1x2 inch x 7d ring shank the nailer of each No.2 SYP Three {3) 18 nail straight -nailed female lock or One (1) 18 ga. 'h- anchored to ga.114-inch crown through the rafter spaced 164nch o.c. inch crown x 1-inch One (1) min. 1.75-inch Max. rafter with one x 14nch leg into the end of the securing each panel leg staple spaced x 0.072-inch diameter 24J-2 164nch 1) min. 2.25- staples in diamond batten or two lap Wood 8inch o.c. and finishing nail with min. t53.3 inch x 7d ring pattern spaced 16- min. 7nchx7d securing each panel 3116 inch head spaced shank nail inch o.c. hringshankank nails toe- One (1) min. 1.75- lap 16-inch o.c. 244nch o.c. nailed on either side inch x 0.0724nch of the batten at diameter finishing each batteNrafter nail with min. 3116- intersection. Max. inch head spaced rafter spacing is flinch o.c. 244nch o.c. ALC15001.4 FL12194-R7 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for Maximum 24-inch Soffit Span with J-Channel at Wall and Eave Wall Connection Center Connection Eave Connection System Panel MDP No. Width Pso Substrate J-Channel Attachment Panel Attachment Substrate J-Channel Attachment Three (3) 18 ga.1/4-inch crown x One (1) 18 ga.1/44nch crown x 14nch leg staples in diamond 1-inch leg staple securing the nailer Three (3) 18 ga.1/4-inch crownpatternspaced244ncho.c. of each female lock or spaced 16- x 1-inch leg staples in diamond 24JJ-1 Max. Wood securing J-Channel to joists; inch o.c. securing each panel lap Wood pattern spaced 8-inch o.c. 1: 43.5 16-inch One (1) 18 ga.1/4-inch crown x securing1-inch leg staples located in the One (1) min. 1.754nch x 0.0724nch J-Channel to fascia horizontal leg of the J-Channel diameter finishing nail with min. spaced 124nch o.c. 3/16-inch head spaced 4-inch o.c. Three (3) 18 ga.1/4-inch crown x One (1) 18 ga.1/44nch crown x Three (3) 18 ga.1/4-inch crown 14nch leg staples in diamond 1-inch leg staple securing the nailer x 1-inch leg staples in diamond pattern spaced 244nch o.c. of each female lock or spaced 16- pattern spaced 124nch o.c. Max. securing J-Channel to joists; inch o.c. securing each panel lap securing J-Channel to fascia: 53.3 24JJ-2 16-inch Wood One (1) 18 ga.1/4-inch crown x One (1) min. 1.754nch x 0.072-inch Wood One (1) 18 ga.1/4-inch crown x 14nch leg staple securing the 44 4 14nch leg staples located in the horizontal leg of the J-Channel diameter finishing nail with min. nailer of each female lock or spaced 124nch o.c. 3/16-inch head spaced spaced 164nch o.c. securing 44nch o.c. I each panel lap ALC15001.4 FL12194-R7 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B INSTALLATION Note - Refer to the APPROVED Sysrenls section of this report for additional installation details of a selected system and maximum design pressures limitations. No. I Installation Detail 10.5JJ-1 & 14.5JJ-1 Diamond' Patten 18ga., 114' x 1' staples 12' o.c. max 18ga., 114' :1' staples 24' o.c. max J•Channel I ega., 114' x I' staples 24' ox. max Diamond' Patten annul Dnan B 18ga., 114' x 1' staples 24' o.c. max Diamond' Patten 18ga., 114' x 1' T staples 12' o.c, max Detail A ALC15001.4 FL12194-R7 Page 1 of 19 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 12F-1 8 12F-2 No. I Installation Detail - IVIIN. 3/8" HEAD DIA. NAIL. MIN. 1.25" EMBENDMENT SPACED 24' O.C. FOR WOOD SUBSTRATES. MIN. 14GA T•NAIL OR MIN. 9GA, STUB NAIL WITH 3/8' HEAD DIA.. MIN. 5/8' EMBEDMENT SPACED S" O.C. FOR MASONRY SUBSTRATES ASCIA SLIP BOARD SOFFIT MAX. 12•INCH SPAN CHANNEL FASCIA LIP 1/4" FASCIA TRIM STAPLE SOFFIT TO FASCIA BOARD #T50 3/8" X 3/8" STAPLE 16" O.C. L-PAINTED S.S. 1 3/4" TRIM NAIL MIN. 5 NAILS PER 12' PIECE SOFFIT & FASCIA DETAIL ALUMINUM COILS. INC Soffits Appendix B ALC15001.4 FL12194-R7 Page 2 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 112F-3 CREEK TECHNICAL SERVICES, LLC No. I Installation Detail ALUMINUM COILS, INC soffits Appendix B OPEN RAFTER "st'O1 , SOFFIT STAPLE 3/a- DIAMOND PATTERN x /4 CROWN STAPLES t I DETAIL USING A DIAMOND 3'r TKp1J PATTERN FACIA BOARD sT wits i I CAP 3/4- X 1/4- CROWN4S.S. 8' 1 FACIA BOARD STAPLE ON CENTER 1-3/4' TRIM NAIL P' F- CHANNEL CAW BE PAINTED S.S. 48' INSTALLED CAPWITHTHEO.C. FASCIA NAILING FLANGE UP OR 3/4- X 1/4' DOWN CROWN STAPLE SOFFIT -max. 12-inch span WOOD S SUBSTRATE SOFFIT & FASCIA DETAIL ALC15001.4 FL12194-R7 Page 3 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC No I Installation Detail 112F-4 MIN. 14GA T•NAIL OR MIN. 9GA. STUB NAIL WITH 3/8' HEAD DIA., MIN. 6/8' EMBEDMENT SPACED S" O C. FOR MASONRY SUBSTRATES. ASCIA SLIP BOARD SOFFIT MAX. 12•INCH SPAN F" CHANNEL FASCIA TRIM 11-3/4' TRIM MLI %1 FACIA BOARD PAINTED S.S. j/ FASCIA CAP 3/4" X 1/4' CROWN STAPLE SOFFIT J SOFFIT & FASCIA DETAIL ALUMINUM COILS, INC soffits Appendix B ALC15001.4 FL12194-R7 Page 4 of 19 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. r CREEK TECHNICAL SERVICES, LLC System No. I Installation Detail 1 12J-1 OPEN RAFTER 3/4" X 1/4- CROWN STAPLE -24- ON CENTER USING A DIAMOND PATTERN Li —CHANNEL screwed to soffit with one(1I hS r. 1/2" r. 3/8" head 1-3/4" TRIM NAIL PAINTED S.S. 48" O.C. diameter screw, 16" o.c. WOOD OR BLOCK SUBSTRATE SAFFrr—max. 12-inch span ALUMINUM COILS, INC soffits Appendix B 3rtr 318 r- 3/4' X 1/4' CROWN STAPLE SOFFIT STAPLE FACIA BOARD DIAMOND PATTERN DETAIL L 3/4" X 1/4- CROWN FACIA BOARD STAPLE "8" ON CENTER 1-3/4' TRIM NAIL PAINTED S.S. FASCIA CAP 3/4" X 1/4- CROWN STAPLE SOFFIT SOFFIT & FASCIA DETAIL ALC15001.4 FL12194-R7 Page 5 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC No. I Installation Detail 12JJ-1 & 16JJ-2 189a.,114' x I" staples 12- o.c. max W 1 18ga.,114" x 1' 3Af8- staples 24' O.C. Max Diamond- Patten ALUMINUM COILS, INC Soffits Appendix B 189a.. 114" x 1' staples 24' O.C. Max Diamond- Patten Deter! 8 I ega.; 114" x t' Stapies 12' o.c. max Diamond Patten 18 ga.,1/4' x 1" staples in horzonlal leg offema e lap Channel DeteY A ALC15001.4 FL12194-R7 Page 6 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail 13W LDrx6 X 0 072'DIA. 11W NAIL WITH 3116' FZAD DIA, FASCA BOARD SPACED 16' C.0 FASCIA CAP SOFFIT 1' X l:d' CROWN STAPLc OPEN RAFTER WN llrA T' RAIL OR MIN, FASCIA BOARD 9OA STUB NAIL W iH e5' WEAD 16F-1 EDE En SOFFIT & FASCIA 16F-6 SPACED S'C.C. DETAIL FASCIA CAP; REFER TO SOFFIT I FASCIA DETAL F' CHANNEL SOFNT; YAX. IV SPAN MASONRY -A SUBSTRATE I ALC15001.4 FL12194-R7 Page 7 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 16F-3 & 16F4 No. I Installation Detail SOFFI T F" CHANNEL i%god, COncre[a or Block. W FASCIA LIP 1 /4" MIN. 3/8" HEAD DIA. NAIL, MIN. 1.25" EMBENDMENT SPACED 24" O.C. FOR WOOD SUBSTRATES. MIN. 14GA T•NAIL OR MIN. 9GA. STUB NAIL WITH 318" HEAD DIA.. MIN. 5/8" EMBEDMENT SPACED 8" O.C. FOR MASONRY SUBSTRATES. ASCIA SLIP BOARD FASCIA TRIM STAPLE SOFFIT TO ASCIA BOARD #T50 8" X 3/8" STAPLE 16" O.C. L—PAINTED S.S. 1 3/4" TRIM NAIL MIN. 5 NAILS PER 12' PIECE SOFFIT & FASCIA DETAIL ALUMINUM COILS, INC Soffits Appendix B ALC15001.4 FL12194-R7 Page 8 of 19 This evaluation report is provided for Slate of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail I 3nKTWM SOFFIT STAPLE OPEN RAFTER OLD 3/4- X 1/4• DIAMOND PATTERN I ! 1 D ETAI L 3/ri CROW STAPLES IlUSINGADIAMOND --.7 s its ERN PATTFACIA BOARD FASCIA CAP 16F- 5 3/ 4' X 1/4' CROWN FACIA BOARD 8' 1-3/4' TRIM NAIL STAPLE ON CENTER 1- 3/4' TRIM NAlL PAINTED S.S. F' CHANNEL CAN BE PAINTED S.S. 48' FASCIA CAP INSTALLEDWITHTHEO.C. NAILING FLANGE UP OR 3/4' X 1/4' CROWN STAPLE SOFFIT- max. 16-inch span WOOD SOFFIT SUBSTRATE SOFFIT & FASCIA DETAIL ALC15001. 4 FL12194-R7 Page 9 of 19 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC No. I Installation Detail RAFTER 1' x VS C Irer 7DF'LE YSTDLLED 16F-2 & DAITECUIl olDuo4D 16F-7 ALUMINUM COILS, INC soffits Appendix B AIL W01H3xO ORDID TRW11 /1 /—FASCIA BOARD NA4Lti9iH3/16'HEAD OID FASCIA CAP, REFER TO SOFFIT 3 FASCIA At F' CMAN4E1 SOFfIT; MAX IA- SPAH SUBSTRAIt FASCIA CAP 1' X I/_ CAMW STAPLE coo SOFFIT & FASCIA DETAIL m 11J' A I' staples Diamon0' Paden ALC15001. 4 FL12194-R7 Page 10 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC System No. I Installation Detail 16J-1 3/4- X 1/4- CROWN STAPLE '24' ON CENTER USING A DIAMOND PATTERN WOOD OR BLOCK SUBSTRATE OPEN RAFTER iOIST FACIA BOARD FASCIA CAP 1-3/4' TRIM NAIL) PAINTED S.S. 48' O.C. SOFFIT —max. 16-inch span 3/4' X 1/4- CROWN STAPLE '8' ON CENTER ALUMINUM COILS, INC Soffits Appendix B 3/4- X 1/4' CROWN STAPLE SOFFIT STAPLE DIAMOND PATTERN DETAIL 1-3/4- TRIM NAIL I FACIA BOARD PAINTED S.S. AIr FASCIA CAP 3/4- X 1/4- CROWN STAPLE SOFFIT SOFFIT & FASCIA DETAIL ALC15001.4 FL12194-R7 Page 11 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shag notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC System No. I Installation Detail A 189a., 114' x V staples 12' o.c. max 16JJ-1 \ 189a.,114- x 1' staples 24' o.c. max Diamond Patten Detad S 1 ALUMINUM COILS, INC Soffits Appendix B 189a., Vex 1` staples 24- O.C. Max Diamond Patten annal 18ga..114• x V staples 6' o.c, max Diamond Patten Z--/ 1 Channel Detai A ALC15001.4 FL12194-R7 Page 12 of 19 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC System No. J Installation Detail 122.5JJ-1 OPEN RAFTER 18 ga , 114' x 1' staples 16' o c, max and 1 3,14" Long x .072' Dia. Trim Nails with 311V Head 4' 318- D.c. max Diamond' Patten I Sga.,114' x 1' staples 17* D.C. max ALUMINUM COILS, INC Soffits Appendix B 18ga., 1/4'x 1' staples 24' D.C. max Diamond' Patten annal Dead 8 18ga., t!d' x 1' 1 figa.,114' x 1' staples staples 24- D.C. Max r- ' Diamondd" Patmax all ox. en r f \ 189a., 114' x 1' staples 12' o.c. max J- Channel DEt09 A ALC15001A FL12194-R7 Page 13 of 19 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES. LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail P IiRW NAR FASCIA BOARD AD1TfD S.S. I 1-. 1' CROWN FASCIA CAP STAPLES SOFFIT USING A DIAMOND PATTERN, REFER TO 1".!' CROWN STAPLE SOFFIT STAPLE DIAMOND PATTERN DETAIL I TRIM NAIL FASCIA BOARD PAINTED S.S. SOFFIT 8 FASCIA DETAIL 24F- 1 & 24F.- 4 1'.;- CROWN STAPLE FASCIA CAP; REFER TO SOFFIT A FASCIA DETAIL Nominal 1'.2" SYP I' d Batten An[Aored to SOFFIT; MAX. 24' 1 F-(NAtINEI Ratters vile an I'd Ring Shank Nail at / every Railer / MOOD SUBSTRATE-\ / SOFFIT STAPLE DIAMOND PATTERN ALC15001 4 FL12194-R7 Page 14 of 19 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail I t' TRW MAIL FASCIA BOARD PANTED S.S. 1-4' SM00710 SHANK FASCIA CAP ROOF MAILS SOfFIi 1'4- CROWM STAPLE I I t' TRIM IIAR FASCIA BOARD PANTED S.S. SOFFIT 9 FASCIA 24F-2 & DETAIL 24F-5 1'4' CROWN STAPLE FASCIA fA; REFER TO SOFFIT 1 FASCIA DETAk Moeonal r12- SYP Balten Antho: ed to SOFFIT; MAX. 24- F•CHAMNEL Ratters with one TO Ring Shan% Mail at every Rafter WOOD SUBSTRATE ALC15001.4 FL12194-R7 Page 15 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail 1 t TRin NAIL FASCIA BOARD PAWTED S.S. t tsGA l' 1•NABS i FASCIA CAP SOFFn 1'st' CROWN STAPLE 1 l' TRIM NAIL FASCIA BOARD PAVITEO S.S. SOFFIT 8 FASCIA DETAIL 24F-3 & 24F-6 I 1'a!- CROWN STAPLE FASCIA UP; REFER 10 SOFFIT i FASCIA DETAIL rat' SYP Batten Antherea to SOFFIT; MAX. A* F-CHANNEL Ratters -ith one td Ring Shank tw at every Rafter MASONRY ALC15001.4 FL12194-R7 Page 16 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CR E E K ALUMINUM COILS, INC I Soffits TECHNICAL SERVICES, LLC Appendix B System No. Installation Detail 1I. TRIM NAIL FASCIA BOARD PAINTED S.S.---\ 1'.4- CROWH STAPLES FASCIA CAP USING A CIAMON, SOFFIT PATICRN; REFER TO ' CROWN STAPLE SOFFIT STAPLE [ANTILEVERED t' DIAMOND PATTERN RAFTER IVAN FASCIA BOARD 1 iRIM NAIL SOFFIT 8 FASCIA PAW1E0 ss. DETAIL 24J.1 rsi- CROWN STAPLE 24J-2 — FASCIA CAP, REFER •— TO SOFrn S FASCIA OfTAtt / \ tlotreut 1' r SVP Detlenf 8• sceheeo ith a n 1)?d and SOFFIT: MAX 24• 1-(MANNEL Aan "s om(t17arinp Isham, nau shmgM•naueO Inroupn Uta or (2to Inc rnO WOOD SUBSTRATE of the canon a t;. (j) de Ling slWnk naus toe•naseO on \ that side OI Ine oattem t1 Vto Wttentrttter uhetsawn / SOFFIT STAPLE DIAMOND PATTERN ALC15001.4 FL12194-R7 Page 17 of 19 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES. LLC ALUMINUM COILS, INC soffits Appendix B System No. Installation Detail 1893 , 114" x I' staples 24- o C. Max 0PEN PAPMR Diamona" Patten 18ga.. 114" x 1' o,sy staples 12- o.c. max B A 13 ga., 114" x V staples 16" o.c, max and 1 Y4 Long x .072" Dla. Tnn1 J-Channel Npds with 3116" Head 4" 318' o.e max DetOd e 24JJ-1 I8ga..114' x I" staples 24' o c. max I Sga.,114' x t' staples 8' o.c. max Diamond Patten J•Channel DOW A ALC15001.4 FL12194-R7 Page 18 of 19 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail 18ga.,114' x 1' staples 24' o.t max OPEN RnfTER Diamond' Patten 18ga..1/4' x 1' oiST staples I o.c. max B i A V a J 18 aa, 1/4' x 1 staples 16" a.c. max and 1 314* Long x .072" Dia. Trim J-Channel Nad, Willi 3/16" Heatl 4" ar o.c. max oetaa a 24JJ-2 1 Bga., 1!4" X 1' 18ga., 110' x 1' 31r staples 24' D.C. Max staples I r D.C. max 1 Diamond' Patten Diamond' Patten 18 ga., 114' x 1' staples In horzontal leg offemale lap J-Channel Detail A ALC15001.4 FL12194-R7 Page 19 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein CREEK ALUMINUM COILS, INC Soffits0TECHNICALSERVICES. LLC Appendix C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-10 under the following provisions: 1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC. 2. Exposure B, C, and D shall be as defined in section 1609 of the FBC. 3. Design wind loads are provided only for walls/soffits with a mean roof height less than or equal to 60-ft. 4. All calculations are based on an effective wind area of 10-ftz or less. 5. Topographic factors such as escarpments or hills have been excluded from the analysis. 6. Wind directionality factor, Kd = 0.85 7. Vul, is shown in the tables below. Design pressures are multiplied by 0.6 in accordance with Section 1609.1.3 of the FBC. B. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional. 9. Zones 4 and 5 shall be defined as shown below. Dimension 'a' shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever is smaller, but not less than either 4% of the least horizontal dimension or 3-ft. ALC15001.4 FL12194-R7 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC soffits Appendix C Design Wind Pressures for Soffits in Exposure B Building Type Zone Mean Height eRoofftpr6. Basic Wind Speed m h 130 140 150 160 170 180 190 200 Enclosed 4 20 19.8 22.9 26.3 30.0 33.8 37.9 42.2 46.8 25 19.8 22.9 26.3 30.0 33.8 37.9 42.2 46.8 30 16.9 19.8 22.9 26.3 30.0 33.8 37.9 42.2 46.8 40 18.3 21.5 24.9 28.6 32.5 36.7 1 -41.2 45.9 50.8 50 19.5 22.9 26.5 30.5 34.7 39.1 43.9 48.9 54.1 60 20.5 24.0 27.8 32.0 36.4 41.1 46.0 51.3 56.8 Negative Loads) 5 20 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57 8 25 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 30 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 40 22.6 26.5 30.7 35.3 401 45.3 50.8 56.6 62.7 50 24.1 28.2 32.8 37.6 42.8 48.3 54.1 60.3 66.8 60 25.3 29.6 34.4 39.5 44.9 50.7 56.8 63.3 70.1 Enclosed 4 20 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 25 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 30 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 40 11.7 13.8 16.0 18.3 20.8 23.5 26.4 29.4 32.5 50 12.5 14.7 17.0 19.5 22.2 25.1 28.1 31.3 34.7 60 13.1 15.4 17.8 1 20.5 23.3 1 26.3 29.5 32.9 36.4 Positive Loads) 5 20 10.8 12.7 14.7 1 16.9 19.2 21.7 24.3 27.1 30.0 25 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 30 10.8 12.7 147 16.9 19.2 21.7 24.3 27.1 30.0 40 11.7 13.8 16.0 183 20.8 23.5 26.4 29.4 32.5 50 12.5 1 14.7 1 17.0 19.5 1 22.2 25.1 28.1 1 31.3 1 34.7 60 13.1 1 15.4 1 17.8 20.5 1 23.3 26.3 29.5 1 32.9 1 36.4 ALC15001.4 FL12194-R7 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix C Design Wind Pressures for Soffits in Exposure C Building Type Zone Mean Roof Height ft Basic Wind Speed m h 120 130 140 150 160 170 180 190 200 Enclosed 4 20 21.7 25.4 29.5 33.8 38.5 43.5 48.7 54.3 60.2 25 22.6 26.6 30.8 35.4 40.2 45.4 50 9 56.7 62.8 30 23.6 27.7 32.1 36.9 41.9 47.3 53.1 59.1 65.5 40 25.0 29.4 34.1 39.1 44.5 50.2 56.3 62.7 69.5 50 26.2 30.8 35.7 41.0 46.6 52.6 59.0 65.8 72.9 60 27.2 31.9 37.0 42.5 48.3 54.6 61.2 68.2 75.5 Negative Loads) 5 20 26.7 31.4 36.4 41.8 47.5 53.7 60.2 67.0 74.3 25 27.9 32.8 38.0 43.6 49.6 56.0 62.8 70.0 77.6 30 29.1 1 -34.2 39.6 45.5 51.8 58.4 65.5 73.0 80.9 40 30.9 36.3 42.1 48.3 54.9 62.0 69.5 77.5 85.8 50 32.4 38.0 44.1 50.6 57.6 65.0 72.9 81.2 89.9 60 33.6 39.4 45.7 52.5 59.7 67 4 75.5 84.2 93.2 Enclosed 4 20 13.9 16.3 189 21.7 24.7 27.9 31.2 34.8 38.5 25 14.5 17.0 19.7 22.6 25.8 29.1 32.6 36.3 40.3 30 15.1 1 17.7 20.6 23.6 26.9 30.3 1 34.0 37.9 42.0 40 16.0 18.8 21.8 25.1 28.5 32.2 36.1 40.2 44.5 50 16.8 19.7 22.9 26.3 29.9 33.7 37.8 42.1 46.7 60 17.4 20.5 23.7 27.2 31.0 35.0 39.2 43.7 48.4 Positive Loads) 5 20 13.9 16.3 18.9 21.7 24.7 27.9 31.2 34.8 38.5 25 14.5 17.0 19.7 22.6 25.8 29.1 32.6 36.3 40.3 30 15.1 17.7 20.6 23.6 26.9 30.3 1 34.0 37.9 42.0 40 16.0 18.8 21.8 25.1 28.5 32.2 36.1 40.2 44.5 50 16.8 19.7 22.9 26.3 29.9 33.7 37.8 42.1 46.7 60 17.4 20.5 23.7 27.2 31.0 35.0 39.2 43.7 48.4 ALC15001.4 FL12194-R7 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC soffits Appendix C Design Wind Pressures for Soffits in Exposure D Building Type Zone Mean Roof Height ft Basic Wind Speed m h 120 130 140 150 160 170 180 190 200 Enclosed 4 20 26.0 30.5 35.4 A0.6 A6.2 52.2 58.5 65.2 72.2 25 27.0 31.6 36.7 42.1 47 9 54.1 60.6 67.6 74.9 30 27 9 32.8 38.0 A3.6 A9.6 56.0 62.8 70.0 77.5 40 29.4 34.5 40.0 45.9 52.2 58.9 66.1 73.6 81.6 50 30.6 35.9 A 1.6 47.8 54.3 61.3 68.8 76.6 84.9 60 315 37.0 42.9 49.3 56.1 63.3 70.9 79.0 87.6 Negative Loads) 5 20 32.1 37.7 43.7 50.1 57.0 1 -64.4 72.2 80.4 89.1 25 33.3 39.1 45.3 52.0 59.2 66.8 74.9 83.4 92.4 30 34.5 1 40.4 46.9 53.8 61.3 69.2 77.5 86.4 95.7 40 36.2 42.5 49.3 56.6 64.4 72.7 81.5 90.9 100.7 50 37.7 44.3 51.4 58.9 67.1 75.7 84.9 94.6 104.8 60 38.9 45.7 53 0 60.8 69.2 78.1 87.6 97.6 108.1 Enclosed 4 20 16.7 19.5 22.7 26.0 29.6 33.4 37.5 41.7 46.3 25 17.3 20.3 23.5 27.0 30.7 34.7 38.9 43.3 48.0 30 17.9 1 21.0 24.3 27.9 31.8 35.9 40.2 44.8 49.7 40 18.8 22.1 25.6 29.4 33.4 37.8 42.3 47.2 52.2 50 19.6 23.0 26.7 30.6 34.8 39.3 44.1 49.1 54.4 60 20.2 23.7 27.5 31.6 35.9 40.5 45.4 50.6 56.1 Positive Loads) 5 20 16.7 19.5 22.7 26.0 29.6 33.4 37.5 41.7 46.3 25 17.3 20.3 23.5 27.0 30.7 34.7 38.9 43.3 48.0 30 17.9 21.0 24.3 27.9 31.8 35.9 40.2 44.8 49.7 40 18.8 22.1 25.6 29.4 33.4 37.8 42.3 47.2 52.2 50 19.6 23.0 1 26.7 1 30.6 34.8 1 39.3 1 44.1 49.1 1 54.4 60 20.2 23.7 1 27.5 1 31.6 35.9 1 40.5 1 45.4 50.6 1 56.1 ALC15001.4 FL12194-R7 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 3/8" F-Channel 3/8" J-Channel 1 3/8" 3/4" 1/8" HEM T 7 3/4" 1 3/B' ISOMETRIC VIEW 3/E' PROFILE ISOMETRIC VIEW 3/2- PROFLE ALUMINUM COILS, INC Soffits Appendix D ALC15001.4 FL12194-R7 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. a. Fascia CREEK TECHNICAL SERVICES, LLC 3/4" 7/8" 1/8" HEM 1 1/4" 6"FASCIA 7" BLANK ISOMETRIC VIEW ALUMINUM COILS, INC Soffits Appendix D ALC15001.4 FL12194-R7 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20.3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 16" 04 Soffit 18' BLANK 3 / 8 PRonLE us -ace ALUMINUM COILS, INC Soffits Appendix D ALC15001.4 FL12194-R7 Page 3 of 4 This evaluabon report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 12" T4 Soft 31/8" 7/8" 31/8" 7/8" 31/8" 5/16" 1/2" 1/1" 1/1" 112" 3!/r 13.75" BLANK 3/8" PROFILE 2jW .rd C 2 'Y1 I( Q f2f'ir I D D D D D DDDD DDDDD D D D D DDDDD D D D D ALUMINUM COILS, INC Soffits Appendix D END OF REPORT ALC15001.4 FL12194-R7 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Florida Building Code Online https://www.Floridabuildiilg.org/pr/pr app_dtl.aspx?paranl=wGEVX..., 1 ProfessionalBusiness & Regulation G=1 SCIS home I tog In I User Reglstmllon 1 Hot Top16 ! Submit Surcharge I Stats 6 facts Publ[auons P8C Staff SCIS See Map ; Links I Search F lida 11 Product Approval USER: Pubik User L 'Y""rr 1. to P10cNa-6gomval Menu > PI[IdrSt or Aooaca.LRO_StdrSJ! > 600YAt.I.ttA > AppQ=Uon OetaB FL # FL7006-R10 Application Type Revision Code version 2017 Application Status Approved Approved by DBPR. Approvals by D8PR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Emall Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) IKO Industries, Ltd 40 Hansen Road South Brampton, NON -US L6W 31-14 708)496-2800 Ext200 rmetz0010tampabay. rrcom Robert Metz rmetzOO1@tampabay.rr.com Bob Metz REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 727)776-5261 rmetzOO1@tampabay.rr.com Don Shaw IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 717)579-6706 don.shaw@Iko.com Roofing Asphalt Shingles Certification Mark or Listing FM Approvals - CER Locke Bowden P.E. Validation Checklist - Hardcopy Received Standard ASTM D3161 modified to 110 mph ASTM D3462 ASTM D7158 Class H ASTM E108 Year 2016 2010 2011 2011 I of3 4/13/2018, 7:41 AM Florida Building Code Online 1lttps://www. Fl oridabu i Id ing.org/pr/pr_app_dtl.aspx?paranl=wG E VX... Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option A 10/08/2017 10/30/2017 11/01/2017 Summary of Products FL At A Model, Number or Name Description - 7006.1 - - Cambridge, Cambridge HO, - Laminated architectural fiberglass asphalt shingle Blltmore and Blltmore HO i manufactured at IKO's Kankakee IL; Hawkesbury Ont - Limits of Use ----.-.. •-----------__, Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 1 --- 7006.2 Hip and Ridge 12 Cap I Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants Certification Agency Certificate v EL7 OQ6R10CSACLMr - TM D-3 4 le er - 936-2017)_frQm FM.pdf fl7006 R10 C CAC Letter_ASTM D3462lettgr_ 2-26-2A].Z).pdf FL7lJQ6 R10 C CAC Letter -ASTM ELQB letter - 9 26_2017J.Qdf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 RIO II iKQ-07-02-01 Letter - Installation i Instructions for FBC FL7006.pjf Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: ThIs Is a 12" x 12" fiberglass asphalt shingle used to cover i the hip and/or ndge of an asphalt shingle roof system manufactured at IKO's Kankakee, IL, Toronto, Ont. and Brampton, Ontario plants. Certification Agency Certificate ft7Q06 RIO C CAC ASTM D 3A62 - Shingle le r Surv_gU! nce Audit_LQ-tLio-n=(6-28-2017),pQf f 7006 R30 C CAC Letter A$7M_D]61 letter - 23Sz=24J,Z) figm FM,QQf FL700¢ R10 C CAC Letter -ASTM D346 letter - f9-26__ 0 7 .pX FL7006 RIO C CA —letter - ASTM E108 letter-: 9:26-2017),0.d1 Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 RIO If Hip and Ridge a hingle Installation jPstrVgt9n£pd.f FL7006 R10 II IKO-187-02 O3 Leiter - lnstalla(jon In$trv.ctions for FBC Ft,A006_2df Verified By: Ouc T Nguyen PE 65034 Created by Independent Third Party: No l Evaluation Reports Created by Independent Third Party: 7006.3 _ - Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at Starter Strip the bottom of a roof system manufactured in Brampton and Hawkesbury, Ontario plants Limits of Use - - - - -- - Certification Agency Certificate - -- - --- - -- Approved for use in HVHZ: Yes FL70Q6 R 9 C CAC Letter - ASTM D3161 letter - Approved for use outside HVHZ: Yes (9_26-2017 from EM PAf Impact Resistant: N/A FL7006 R10 C SAC Letter - AST M D3462 letter - Design Pressure: N/A (9-26-2017),pdf 2 of 3 4/13/2018, 7:41 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVX.... I Other: FL7006 R10 C_GgC Letter - ASTM _Q1Q9-letter - 9-26-2017).Ddf Quality Assurance Contract Expiration Date 1 12/31/2020 i 1 Installation Instructions FL7006 R10 It IKO- 87-02-01 Letter - Instailel on InsVuctlonr FBC FL7006.odf EL7006 Rb0 11 Roofino- Products- Leading_Ed a-Plus- Applicatlon_ EIV(j)_p01f I Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No I Evaluation Reports I Created by Independent Third Party: 7006. 4 1 Marathon Plus AR, Superglass Plus 13 tab fiberglass asphalt shingle manufactured at IKO's AR IBrampton, Ontario, Hawkesbury Ont., Toronto, Ont.; Sylacauga, AL and Kanakakee, IL plants Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Certification Agency Certificate fL7 6 R10 C CAC Letter -A5EM D3161jetter- i9_ 2S#_2Qu)-from FM.pdff FL7046 R10 C CAC er - ASTM D3462 letter - 9_ 26-2017).pdf FL7006 R30 C CAI;Lgtter - ASTM E108 letter 9= 26= 2017 ),pdf Quality Assurance Contract Expiration Date 12/ 20/2020 Installation Instructions fb7SiQfLR10 lI IKO-187-02 O3 lgtt0r_tnstIllation Instructions fgr FBC FL7006.odf Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No j Evaluation Reports Created by Independent Third Party: Badr Nerct C, ontect Ug :: 2601 Slaw Slone Road. TakhaspqS FJ_W22 Phone. SSO-487-1824 The Slate of Florida IS an AA/EEO employer. SQMyMht 2007-2013 State of Florida .: • EWM Statemem :: Atcesslblky Statement:: gq tlmGsn Under Florida law, email addresses am public records. If you do not want your a -mar address released In response to a publik-records request, do not send electronic mad to this entity. Instead, contact the oflke by phone or by tred[lonal mad If you have any questions, please contact 850 487.1395. 'Pursuant to Section 4SS. 275(1), Florida Statutes, effechve October 1, 2012, licensees licensed under Chapter 455, F.S. must pmvde the Department with an email address f they have one. The emalt9 provided may be used for oBkYl communication with the licensee. However email addresses are public record. it you do not wish to supply a personal address, please provide the Department with an email address whch can be made available to the public. To determine of you are a licensee under Chapter 455, F.S., please click homer . Product Approval Accepts: Credit Card Safe 3 of 4/13/2018, 7:41 AM CONSTRUCTION MATERIALS T E C H N 0 L 0 G I E S October 27, 2017 IKO Industries, Ltd 120 Hay Rd. Wilmington, DE 19809 Re: FBC FL7006 Sir(s), PRI Construction Materials Technologies has completed a technical review and attached sealed shingle instructions in compliance the 2017 Florida Building Code. This review was completed based on the receipt of following evidence from IKO Industries, Ltd: 1) IKO Shingle Application Instructions — 3-Tab Shingles EN-3Tab Appins_8AGXEFS-2012-11_reformatted 2013-02-rev07/13-Florida) 2) IKO Laminated Shingles Application Instructions EN -Laminated Appins_8TTEFS-2012-04 reformatted 2013-02-rev07/13-Florida) 3) IKO Hip and Ridge 12 Application Instructions EN-HipandRidgel2-3HRTri-2013-08_reformatted 2013-08) 4) IKO Leading Edge Plus Shingle Application Instructions EN-3LEP-Tri-2012-06—reformatted 2013-03) 5) ASTM D3161 Test Report (FM Approvals Project No. 3040947) The attached instructions should be used in conjunction with the published manu(acturer's application instructions and applicable code. In the event the instructions conflict, these instructions shall govern. Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. Signed: +, i• , j t Signed Brad Grzybo ski Managing D rector Date: October 27, 2017 Date: Attachments: A) IKO Shingle Application Instructions - 3-Tab B) IKO Laminated Shingles Application Instructions C) IKO Hip and Ridge 12 Application Instructions D) IKO Leading Edge Plus Application Instructions IKO-187-02-01 Mk-c/-, u - - t - A - , -'L Duc T. ueA Florida Rilglgtere Professional Engineer P.E. Number: 66034 October 27. 2017 PRI Coronicdon Materials Technologies, LLC. 6412 Badger Ddw Tampa, FL 33610 Tet 813.621.5777 Fax: 813-621-5840 e-mail: maleriatslas6ngt6p6cmLoom WebSite: httpJMm.pdcmt.00m IKO Installation Instructions for Asphalt Shingles Page 2 of 5 IKO Shingle Application Instructions — 3-Tab Shingles ASTM D3161, Class F — IKO Marathon 25 AR and CRC Superglass M25AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed 6-1/8" above the butt edge, approx. 1" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (600) or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8". STEEP SLOPES SEALING STRIP 12 I I 611a" NAILS NAILS DO NOT NAIL INTO OR ABOVE THE SEALING STRIP PRI Collsbuc0on Matelots Techrlobgles, I.I.C. 6412 Badger Drive Temp& FL 33610 Td: 813-621.5777 Fax: 813-621.5840 email: materialstesgrig&ricmtcom WebSlte: htlpJAwrvepdcmLeom IKO Installation Instructions for Asphalt Shingles Page 3 of 5 IKO Laminated Shingles Application Instructions ASTM D3161, Class F — Cambridge, Cambridge HD, and CRC Biltmore AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed in the nail line 7-318" below the top edge, approx. 1" and 13" in from each end. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (60°) or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8". f 1 318' NAIL LINE 63rat j NAILS NAILING -STEEP SLOPES APPLICATION Use six nails as shotiwi. F_ F1CEMENT PROPER APPLICATION REOUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OF THE SHINGLE PRI Construe0on Matedals Techrdogles. U.C. 6412 Badger Drive Tampa. FL 33610 T& 813.621,TM Fax: 813.621.5840 e-mail: materialstesling&ftmi com WebSlte• ht4r.J w jw.pdcm1.cem IKO Installation Instructions for Asphalt Shingles Page 4 of 5 IKO Hip and Ridge 12 Application Instructions ASTM D3161, Class F — IKO Hip and Ridge 12) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are designed for a 51/8" (130 mm) exposure. (For a neater appearance, the top of each side of each piece has been factory trimmed on a 1" (25 mm) taper (see drawing). Bend each piece over the hip or ridge, and nail 5 5/8" (143 mm) above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 1/8" (130 mm). Apply hip pieces starting at the lower end of the hip, working up toward the ridge. On hip roofs, apply ridge pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end opposite to the prevailing wind direction and continue to the other end. Note: To obtain a three-dimensional effect, (which is recommended, but not required), apply hip and ridge shingles double thickness by stacking 2 pieces on top of one another, the lower piece extending about 3/4" (19 mm) further than the top piece (see diagram). The final shingle should be set in cement, and the exposed nail heads of the final shingle should be covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for easier bending. NOTE: SHINGLES MUST BE APPLIED PROPERLY. THEYARE DESIGNED FOR USEAS HIP AND RIDGE SHINGLES ONLY, AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS. REVIEW ALL APPLICABLE BUILDING CODES, MINIMUM PROPERTY STANDARDS, AND REQUIREMENTS PRIOR TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. mn UPER COI PRI CW&Wceon MaterIals Technologies, U.C. 6412 Badger Me Tampa, FL 3300 Tel: 813-621.5777 Fax: 813-621-5840 e-mall: matedalstesdng@prkmt.com WebSite: hit; Jfwww.pdcmLcom IKO Installation Instructions for Asphalt Shingles Page 5 of 5 IKO Leading Edge Plus Application Instructions ASTM D3161, Class F — IKO Leading Edge Plus) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. 1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required 2. Each 39 3/8" x 131/4" (1000 mm x 336 mm) IKO Leading Edge Plus strip is perforated lengthwise for separation into two (2) shingles. Take one IKO Leading Edge Plus strip and fold flat at perforation to separate. 3. Take one of the separated shingles 39 3/8" x 6 5/8" (1000 mm x 168 mm) and remove approximately 20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up, with the factory installed sealant adjacent to the eaves. The shingle should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with nails located 3" to 4" (75 mrn to 100 mm) from the eave edge and 1" (25 mm) in from each end. 4. Take the leftover 20" (500 mm) piece shingle. Rotate the piece and align it vertically up the rake edge with the factory installed sealant adjacent to the outer edge of the roof. The shingle should overhang the rake edge by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with fasteners located 3" to 4" (75 mm to 100 mm) from the rake edge and 1" (25 mm) in from each end. 5. Repeat Steps 3 — 4 for the right lower corner of the roof deck. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" (9 mm) diameter heads, long enough to penetrate through plywood or 3/4" (20 mm) into boards. Use 4 nails per shingle placed 3" to 4" (75 mm to 100 mm) from the eave edge and approximately 1" and 13" (25 mm and 330 mm) in from each end. 6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck. Install the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingles to the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge, 4 nails per shingle. 7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first -course field shingles and help keep them from lifting in high winds. PRI Construction Materials Technologies, tiC. 6412 Radger Odve Tampa. FL 33610 Tel: 813-621.SM Fax: 813-621-5840 0-mall: matedalstesbng@pricmLeom WebSite: http•Jhv w pricmlcorn Florida Building Code Online i. https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVX:... , t 4 ' ProfessionalBusiness & • a fla as aCLS Home I lug In I User Regstratbn Hot Topics submt Surcharge I stets a Pacts I Puohcalbns I FaC Stag aCis site Map Lnks I search FI rida Product Approval ' USER: Pub8c User µo. QoduR_ftVmvaLMMu > RMOo Kt or App1,4t kaJi=Wj > ApakauDnj st > Application Detail FL # FL2346-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archlved Product Manufacturer Warrior Roofing Manufacturing Address/Phone/Emal 3050 Warrior Road Tuscaloosa, AL 35404 205) 553-1734 Ext 115 Steven@WarrIarRoofing.net Authorized Signature Steven Crew Steven@Warriorftoonng.net Technical Representative Steven Crew Address/Phone/Email 3050 Warrior Road Tuscaloosa, AL 35404 205) 553-1734 Ext 1024 Steven@WarrlorRoofing.net Quality Assurance Representative Steven Crew Address/Phone/Email 3050 Warrior Road Tuscaloosa, AL 35404 205)SS3-1734 Ext1024 Steven@WarriorRooflng.net Category Roofing Subcategory Underlayments Compliance Method Test Report Testing Lab PRt Construction Materials Technologies, LLC Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 10/OS/2021 Validated By Jesus Gonzalez, P.E. Validation Checklist - Hardcopy Received Certificate of Independence F 66 7C91 fl1_CMLCe!t of_I_ldepe2 enceAO01 Referenced Standard and Year (of Standard) Standard Year ASTM D226 2009 ASTM D4869 2016 Equivalence of Product Standards Certified By Approved Testing Lab FL2346 R7 Fouiv FBC 2017 Stanoards Eq.uj_vp_[gM_.pA-f I of 2 4/13/2018, 7:44 AM Florida Building Code Online littps://www.floridabui ld ing.org/pr/pr_app_dtl.aspx?parain=wG CVX... Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL # — Model, Number or Name 2346.1- — —#1S and #30 roofing feltI9 Method 1 Option B 01/17/2018 01/17/2018 01/17/2018 04/10/2018 Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A 1 Other: Primary roof covering should be Installed Immediately after felt. Roofing felt is not intended to be an unprotected weathering surface. 12346.2 115w and 30w roofing felt Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Primary roof covering should be installed immediately after felt. Roofing felt Is not intended to be an unprotected weathering surface. Description ASTM D 226 Tested _ Installation Instructions FL2346 R7 II Installation lnsl;pgion$.pdf Verified By: PRI Construction Materials Technologies, LLC Test Reports FL246_R7_TR 15A Test Reoort.gdf FL2346 R7 TR 30A Test Reoort.gdf ASTM D 4869 Tested— Installation Instructions F( 2346 R7 If Installation Instructions. Verified By: PRI Construction Materials Technologies, LLC Test Reports FL2346 R7 TR 1Sw Test Report.edf FL2346 R7 TR 30w Test o_Rgrt,pdf rack Nest contact - us : 2601.alalr 5toneFe211onaLQ1Q.:6A7t fl2.4 The State of Fiorlda is an Aq/EEO employer. S.00yright 2007.2013 raft pfY nda, :: Pnvacv Statement ;; ACr@,55 try-SCatenlCOL •: 8e1U^-d ct•te....nr Under Florida law, emal addresses are public records. If you do not want your a -mall address released In response to a publk-records request, do not send electronic mall to this entity. instead, contact the ofike by phone or by traditional mall. U you have any questions, please contact 850.487.1395. 'Pursuant to Section 45S.275( 1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4S5, F S must provide the Department with an emal address If they have one. The emalls provided may be used for offkml communication with the licensee r4wever emal addresses are pubic record. If you do not wish to supply a personal address, please provide tha Department with an email address which can be made available to the pubic. To determine Ifyou are a licensee under Chapter 455, F. S., please ckk bM. Product Approval Accepts: 0 if: yct Credit Card Safe 2 of 4/13/2018, 7:44 AM WARRIOR® ROOFING MANUFACTURING P.O. BOX 40165 • TUSCALOOSA, AL 35404 • PHONE (205) 5W4734 • FAX (205) 5634755 i 193 LEROY ANDERSON ROAD • MONROE. GA 30655 • PHONE (T70) 207.0693 • FAX (TIO) 207-0775 323 DEVELOPMENT AVENUE • CHAMBERSBURG, PA 17201 • PHONE (717) 709-0323 • FAX (717) 709-0027 Roofing Felt Installation Recommendations Be aware that roofing felt should not be walked upon prior to fastening into position. Proper safety equipment is recommended for all installations. Also, the roof decking should be clear of debris and moisture prior to installation of the roofing felt. Roofing felt should be installed from the bottom of the roof in horizontal layers to increase the water shedding ability of the felt. The initial layer of felt should be installed to cover the bottom edge of the decking, from edge to edge. Overhang is not required. Anchor the top corner of the felt after it has been properly positioned and roll the felt out across the roof. Pay careful attention to roll the felt out smoothly, avoiding wrinkles as you move across the roof. The top edge of the felt should be fastened no less than every eight inches. The middle and bottom edge should also be fastened no less than every eight inches. Fasteners should be applied no less than every eight inches along the eaves. The next course of felt should also be aligned with the roof edge and should overlap the previous course two inches (sometimes referred to as head lap). In the event you get to the end of a roll prior to getting to the opposite edge of the roof, begin a new roll with a four inch overlap over the end of the prior roll (sometimes referred to as end lap). The same fastening pattern used on the middle and bottom of the initial course should be used for each subsequent course. For the top of each subsequent course, fasten intermittently to hold the top edge in place until the next course is applied. The fasteners in the bottom of the next course will hold the top of the previous course securely. Continue up the roof in this manner. Be sure to firmly fasten the top of the final course if it terminates at the top edge of the roof. Otherwise, overlap the felt over the ridge and secure then begin at the bottom of the other side of the ridge and repeat the process. In valleys, lay a vertical section of roofing felt the length of the valley prior to the installation of the horizontal runs of roofing felt. If you use more than one section of roofing felt in a valley, be certain to start at the bottom and overlap each subsequent length a minimum of two inches as you move up the valleyt.ec{water shedding. In the event some wrinkles are created while fastening down a course of felt, slice the wrinkles and fasten them flat to the deck. Then seal the cuts with waterproofing cement. Installation of the primary roof covering (ex. Shingles) is recommended immediately after felt installation. NOTE: LOCAL BUILDING CODES MAY REQUIRE A DIFFERENT FASTENING PATTERN AND/OR SPECIFIC FASTENER TYPES THAN RECOMMENDED BY THESE INSTRUCTIONS. PLEASE CONTACT YOUR LOCAL BUILDING CODE ADMINISTRATOR FOR THE EXISTENCE OF REGIONALLY SPECIFIC FASTENING REQUIREMENTS. CITY OF SANFORD BUILDING & FIRE PREVENTION D PERMIT APPLICATION Application No: 1 , / % / 9 Documented Construction Value: S Job Address: 3 7 i S IJ 4-(t • Historic District: Yes No Parcel ID: Residential W' Commercial Type of Work: New Addition Alteration Repair Demo Change of Use El Move Description of Work: P6yl i i iuty f 0 •f h LIJ14 5 C J Plan Review Contact Person: Title: Phone: Fax: Email: Property Owner Information Name Phone: Street: Resident of property? : City, State Zip: Contractor Information I Name it Ct1't l t t t Cvt 1 Phone: Street: Fax: `l 0 7 - l _ 90? •S(c City, State Zip: S i U otry; , F L 3 `(1 % I State License No.: C. Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Address: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOURPAYINGTWICEFORIMPROVEMENTSTOYOURPROPERTY. A NOTICE OF COMMENCEMENT MUST BERECORDEDANDPOSTEDONTHEJOBSITEBEFORETHEFIRSTINSPECTION. IF YOU INTEND TO OQTA COMMENCEMENT. INFINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY 'BEFORE RECORDING YOUR NOTICE OF Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation hascommencedpriortotheissuanceofapermitandthatallworkwillbeperformedtomeetstandardsofalllawsregulatingconstructioninthisjurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application 60 1 q ) MO 10E: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may befoundinthepublicrecordsofthiscounty, and there may be additional permits required from other governmental entities such as watermanagementdistricts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is requiredinordertocalculateaplanreviewchargeandwillbeconsideredtheestimatedconstructionvalueofthejobatthetimeofsubmittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, inaccordancewithlocalordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work willbedoneincompliancewithallapplicablelawsregulatingconstructionandzoning. Signature of Owner/Agent pate Print owner/Agent's Name Signature of Notary.State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Sigxpatureot./ ai for/Agcnt pate V11L1- LI l)C<T Print Contractor/Agent's Name 7 lhfltR%/>i i, of Rjorida f i 1 Daf, ,la1SSlp; • c' O aY 7. 2,,, rp M S 9FF 12M5 i'i'•' a 7d%: Contractor/Agent is Personally Kno'jj°'tgy br Produced ID Type of ID ''l/;!i,; BELOW IS FOR OFFICE USE ONLY Permits Required: Building[] Construction Type: Electrical Mechanical Plumbing Gas[] Roof Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures of Heads Fire Alarm Permit: Yes No UTILITIES: WASTE WATER: FIRE: BUILDING: Revised: June 30, 2015 Permit Application UNIVERSAL W ik Pro r No: lkilo: 0110.1 6 0817.0000 ENGINEERING SCIENCES Report Date: 8/21/2018 Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Construction Materials Testing • Threshold Inspection Building Inspection • Plan Review - Building Code Administration / I3532MaggieBlvd, Orlando, 32811 - P: 407.4210504 • F: 407.423.3106 l g lJl( In -Place Density Test Report Client: Park Square Homes UES Technician: Sammie Edwards 5200 Vineland Road, Suite 200 Orlando, FL 32811 Date Tested: 08/21/2018 Project: Wyndham Preserve, House Lot Testing East Lake Mary Boulevard 8 Brisson Avenue South, Sanford, Seminole County, FL 32773 Area Tested: 3972 Night Herron (Lot # 68) Material: Native Reference Datum: 0 = Bottom of Footing Tvt)e of Test: Field: ASTM D-2937 Drive Cylinder Method Laboratory: ASTM D1557 Modified Proctor The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. Test No. Location of Test Range aximum DensityDensity pcf) ptimum Moisture del Field Dry i pc f) Field Moisture m Soil Compaction I Native Depth inch) Pass or Fail 1 • North Footing 0-1 ft 106.8 10.6 107.3 5.9 100 N/A Pas: 2 South Footing 1-2 ft 106.8 10.6 107.1 5.6 100 N/A Pas: 3 East Footing 1-2 ft 106.8 10.6 109.1 4.5 102 N/A Pas: 4 North East Comer of Pad (TOF) 1 _2 ft 106.8 10.6 108.2 4.8 101 N/A Pas: 5 Center of Pad (TOF) 2-3 ft 106.8 10.6 1 109.5 1 4.1 1 103 1 N/A I Pas: Remarks: TOF= Top Of Fill 4 Tn nwlnAli..A n .....l..nl n.n#-4— /n 1 /n:..n...nl'n nl:nn/n {Ihn D.•A/:n evil n•.i..nh— nll --,#.. — n..An.:1ie•.l n.. nnnF.lnn/:el nnwnn.A. ni n•....l:nn/.. —1 n../Anri.nl:nn DESCRIPTION AS FURNISHED. Lot 68 , WYNDHAM PRESERVE, as recorded in Plot Book 81. PoyeS 9.5 I!t: n11g11 102 of the Public Records of Seminole County, Florida. HOUNDARY FOR/CERTIFIED TO: Park Square Enterprisks, LLC (a Delaware Corporation); Wlnderweedle, Haines, Ward & Woodman, PA, Attorneys' Title Insurance Fund; Bank of America 9 REMAINDER OF LOT 8 IPALMER'S SUBOMSION PLAT 800K 2, PACE 41 S 00e 18' 02" E 60.00'_ 10' FENCE ESMT. J9. IS' J9. 16' 9 LOT 68 2.7.7 y 10.00' 10.00' p;2.J Q`? ,> JCID a] v CIDe FORM80ARD FOUNDATION g v C4 W LOT 69 W TOF- TOP OF FORM FORM AVERAGE- 24.7J' W (ZI LOT 67 wO 4 6. 13 J 10.00' ej 10 00' J9.87' j1 25.20' 25.20' 10 U71L ESMT P.0 375 87' r------ S 00e 16' 57" Ems.) 60. 00, 17161 ,cS AS FURNISHED r.•;•.:R ' 7.`•' (•e0' LOr) CF 10' +75' I.rp IL° $oETRT - (60' k) LOT) NIGHT HERON DRI11IS' (40' LOT) 15 23' FRONI SETPACK CAN BE REDUCED 30' PRIVATE R/W) 70' ON CERTAIN LOTS. NO MORE 174AN PLOT PLAN AREA CALCULATIONS N SCrESSIO µD A MINIMUM or 2)( N SIGN AT 2 TOTAL LOT AREA 7,141 t SQUARE FEET PNOPOSEO - FINSHED SPOT CRADE ELEVATIONS FUTWORK ON/OFF LOT - TOTAL * SQUARE FEET FLITWORK P• Q ORAIN,V:£ PLANS ORNf 40J/ 110- 513 t SQUARE FEET FOUNOARON/PA° 1.752 .L SQUARE FEEL v`•- - PROPOSF0 ORAINACE FLOW /Q WALKS /9/ JOO- 349 t SQUARE FEET REAR PATIO 119 2 SQUARE FEET FRONT PORCH DECK 99 t SQUARE FEET LILT GRAOINC IYPC A MOD ® S00 4.709/ 230 - 4.959 1 SQUARE FEET POOL DECK N/A t SOUWE FEET PC( HIp5E0 rF. PER PUNS - 24 7' ND7C: rAOHt SIOEMNX AND 57RLlE LOGRON TAKEN IROM PLANS PROMOED Cr CALM Nor r1E1D KRrtIEO CRUSIFAWEYE'R—SCOTT ASSOC., INC. — LAND SURVE)"01i"s' crLN4 • St/AN4 - 5400 E. COLONW. OR. ORUNDO, FL. 32807 (407)-277-3232 fAK (407)-658-14J6 raL. • rmn oN Lnc rro•I. n01[S It Ilq [[ • A S [[KCS[ QRV.11/[ 0 [IMAIMIE 1 M[ M•901AOxm OOLS KR[W C011I` M1t IMS SWM' KRS IK' 1dMON05 OI IR•[ICr S[r /OROI 01' INt /IpRr PMI.i• WI. 1[W rm ? Ptr[IL MPJRI(NI 1.9RNO • .01J441N. rI1WCSf WLw. NIrd70IV AIID W G-RIG !I-,) M1PIIO. nON1IAS1R.Ir•( OmC r11RSYM 10 SCCIW •JTJGr, M1PNM SI•:r'l: 1. ,IAA]S daosao 4Tl PAISCIPIY SSIIPRSN xMD 010014% A• W SEAL MO SLMV -* ON COM MC MOT YJO 1 •l Y IL 1•LS SSL IIR 101-RNOIK IIIE-vf4f4 vP. • VITI[[t rmNT J. TNS SIOO Incf IRON RILL 4RORM•IMN rIEb6K0 10 T+C SLA1.4+1R. /IrOI[ IMr K OII[R 4C.ONCfdJY Pr • rolNi ? MOMAMG CN1 • 4LGMR4 IJIL . rolnl t< rAW4fI•rItt rluL rtl. N I NP[IfII+ OR fXSCM:NIS IIN11.MIE 1141 RROKIIxtAFrET A '0 PAYAGPgRN OPRO14JIE/Ir5 WK IQN LOdRO uMCSS OORRMEf fNOSNMCLICC[ crm—.w fF. • INI1K4 Il1Q QS IIW A n4! SI41Sfr O /[I[AY® r011 IK SPl WWII Or IMO.R c[IITm 10 NO SMONO Wt OE RpKO LRIOn Rr ALP' 011fR pnN. Cilr 4SL. RIM., [CIW1 LIK 4n pRN1,4 4 ONOIOGIS SNORT, nw ME LOCAMN Or 40S101[SIGRS KROW SHP" Not K O30 M R[OPJSN,ICr mPAIRI WSNIGI+•P •vJ.• 1 S«Ix • I:NrLIfNf U • YX KWK 7. OEYMLC7. M[ Wm A"UWO •1MI.Y .WO ON rW LW L1011N AS DISC 41AWC (ae) M•Ix•fA 4. aA%%"OM. a [IIOMII MC at= JM .19M L C00"M M7111CAL OSIW Or I4.M. MNE.,O OIKRMKt IOIFR. ALIt . u i, wN rrnc[ 4.e • ma r e • c`Partr rc [Llr.* I ? WVNTN[ I., a,tu4M[r 4 [!' RIMY IE Or 14I0i07A110N IN. 4 111 SLUE — 1• - 20 —" ORAIIN or.... Mro 0Art OROIIT f4 RIIIIOI 01-0]-701e 20:]-le n LuoIN I . e rORNeW0AR0 FOUNM110TL/ELCLS. 09-03-101R FW4 Iw5 81A 0WC%CRW' M OOCS lar OE WMW FIRM• M !< Y R.4 / 4711 ruE LTIMILGIIELI 100 WAR rL000 PLANE AS NER W SCOR R.LS / 4Q01 sorr. 7. Jf • WP / 1211700090 F (09-2e-07) CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: $ 5558.00 Job Address: 3972 MIN Heron Dr WYNDHAM PRESERVE PB 81 PGS 93-102 Historic District: Yes No Parcel ID: 17-20-31-502-0000-0680 LOT 68 Residential ® Commercial Type of Work: New ® Addition Alteration Repair Demo Change of Use Move Description of Work: Install new 3.54on HVAC system with duct work Plan Review Contact Person: Paula Bagley Title: Permit Clerk Phone: 407-975-2762 Fax: 407-629-9307 Email: permitting@onestopcooling.com Property Owner Information Name Park Sntiara 1-InmPs Phone: 407-529-3000 Street: 5200 Vineland Rd #200 Resident of property? : City, State Zip: Orlando FL 32811 Contractor Information Name One Stop Cooling & Heating, LLC Phone: 407-975-2762 Street: 7225 Sandscove Court Fax: 407-629-9307 City, State Zip: inter Park. FL 32792 State License No.: CAC 032444 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Address: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING,YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit trust be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be Inscribed with the date of application and the code In effect as of that date: 51° Edition (2014) Florida Building Code Revised: June 30. 2015 Pemiit Application t NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued,, OWNER'S AFFIDAVIT: I certify that all of the fordoing information is accurate and that all work will be done in compliance with all applicable laws regulatt g 96structipn and zoning. Signature of Owner/Agent Print Owner/Agent's Name Datc Signature of Notary -State of Florida Date i Kevin Stine Print Contractor/Agent's Name Signature Date KELLY WEBSTER Notary Public . State of Florida Commission N FF 978034 My Comm. Expires Apr 4. 2020 Owner/Agent is Personally Known to Me or Contractor/A et t Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Occupancy Use: Flood Zone: _ Total Sq Ft of Bldg: Min. Occupancy Load: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: FIRE: COMMENTS: Fire Alarm Permit: Yes No WASTE WATER: i BUILDING: Revised: June 30. 2015 Pennit Application 15 lightyears, Inc 15 776 Bennett Drive Longwood, Florida 32750 June 1, 2018 To: Local Building Department RE: Blower Door Test & Duct Leakage Test Reports To whom it may concern, a- / ?/0/ lightyears This letter is to request that the attached forms be accepted for compliance of the 2017 Florida Building Code statute R402.4.1.2 Envelope leakage testing (Blower Door Testing) and R403.3.3 Duct testing. The attached forms were provided by the Florida Building Commission as the accepted forms to be submitted. These forms are listed on the 2017 Florida Building Code, Energy Conservation Technical Assistance Manual, Document Number: TAM-2017-1.0, released February 02, 2018, pages R-78 through R-80 (page numbers 159-161). Web link provided for quick access to the TAM document https://tinyuri.com/2017FBC-TAM These forms meet all three required Residential Energy Efficiency Compliance Paths listed under R401.2, Prescriptive, Performance, and Energy Rating Index (ERI) paths. We are working with building departments across Florida to standardized the form submittal process and would like your department to allow these forms to meet compliance. If there are any issues with accepting these forms, please reach out to me directly and I will ensure that we submit any specific form that you will require. Tim Smith (407)-951-3236 tsmith@151ightyears.com Respectfully, Timothy mith 15 Lightyears, Chief Operations Officer Energy Technical Advisor RESNET Quality Assurance Designee IECC Residential Energy Inspector/ Plans Examiner Member, Building Officials Association of Florida Member and Code Development Committee participating member. Also, representative to the Florida Building Commissions, Energy Technical Advisory Committee for the BOAF- CDC Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: C" 6F 5A^IF6Q0 Permit* IT-Igll Job Information Builder: 0,44k SQUA40 Community: DidalaPqC-SG&UC Lot: 6$ Address:3Q,72 A)IC,07 j-V:R0n1 bA. Unit: City: SA,4FoAb State: FL- Zip:3277,3 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method OPRESCRIPTIVE METHOD- The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2. PERFORMANCE or ERI METHOD- The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or R406-2017 (ERI), section labeled as Infiltration, sub -section ACH50. ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): = 108 X 60 T 21826 = y-7 Method for calculating building volume- CFM(50) Building Volume ACH(50) O Retrieved from architectural plans PASS (Mechanical Ventilation is not required) ® Code software calculated PASS (with Mechanical Ventilation) O Field measured and calculated FAIL R402.4.1.2 Testing. Testing shall be conducted in accordance with AN51/RESNET/ICC 380 and reported at a pressure or 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either Individuals as defined in Section S53.993(5) or (7), Florida Statues, or individuals licensed as set forth In Section 489.105(3)(0, (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2.0ampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3.Interior doors, if installed at the time of the test, shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems, if installed at the time of the test, shall be turned off. 6.Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: 15 LightVears, Inc Phone: (855)438-1515 1 hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: f/1R Date of Test: 03A2/t9 Printed Name of Tester: Michael Estrera License/Certification #: 51684V Issuing Authority: RESNET Copy of License / Certificate of the tester must be attached) Duct Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: CtTy Permit #: I g-1911 Job Information Builder: PAQu SQ%.AQC P,,,&S Community: PACSC-Avc Lot: 63 Address: 3g72 4 60T 6acw 'bQ. Unit: City: Sp,,,jFoQb State: FL ZiP:32-273 Duct Leakage Test Results System 1 cfm25 System 2 cfm25 System 3 cfm25 Sum of any additional systems Cfm25 Total of all systems 31 cfm25 OPrescriptive Method cfm25 (Total) To qualify as "substantially leak free" Qn Total must be less than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.3.3. Is the air handler unit installed during testing? YES (00.') E]NO? 9 ( ) Performance / ERI Method cfm25 (out or Total) To qualify using this method, Qn must not be greater than the 238QS 1 Qn proposed duct leakage Qn specified on Form R405-2017 or R406-2017. Total of all Total Conditioned systems Square Footage Leakage Type selected on Form Qn specified on Form R405-2017 R405-2017 (Energy Colc) or R406-2017 (Energy Calc) or R406-2017 PASS P0:3e") QN. . 3 Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i), Florida Statutes. Testing Company Company Name: 15 Lightyears, Inc Phone: 438-1515 I hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: A. y/lA Date of Test: ma. /9 Printed Name of Tester: Michael Estrera License/Certification #: 51684V Issuing Authority: RFgNFT Copy of License / Certificate of the tester must be attached) LL 1= W z N W ce Certificate of Achievement THIS ACKNOWLEDGES THAT Michael Estrera HAS MET THE STANDARD REQUIRED BY RESNET, AS A CERTIFIED RATING FIELD INSPECTOR R F I # 51684V Certification Date: October 20, 2017 Certification Expires: October 20, 2020 2 Tim Smith, RESNET Quality Assurance Designee 15 ears RESNET QA Provider # (1998-199)