HomeMy WebLinkAbout121 W 1 St #17-1990- Inter RemodelCITY OF SANFORD
UN BUILDING & FIRE PREVENTION
PERMIT APPLICATION
CAW APplwation No: 9— j 9 9z)
Documented Construction Value: `h r ,coo
Job Address: 121 W 1st St. Historic District: Yes ® No ❑
Parcel ID: 25-19-30-5AG-0304-002A \ Residential ❑ Conunercial
1'ype of Work: New ❑ Addition ❑ Alteratioti 4 Repair ❑ Demo ❑ Change of Use ❑ move ❑
Description of Work: Establish a craft brewery with an associated tasting room.
—
Plan Review Contact Person: E-its&=iAinaaq OyS1m �tivrl�jQ1✓lc�� Title: •_Deue4eP Lmaaaw
&i§ 4d7 zcno-c� n �I
Phone: 4�7 �&- Fax: 4� _ I:ruail: i
Property Owner Information SL MV
Name Stephen Tibstra
Street: 5224 W State Rd 46 #305
Plione: 407.488.9656
Resident of property? : No
City, State Zip: Sanford, FL 32771
Name
Street:
City, State Zip:
Contractor Information
Phone:
Fax:
State License No.:
Architect/Engineer Information
Name: K��S�� SSOG I �7�5
Phone:
Street: 11,Y5 S. TV -Ai Fax:
City, St, Zip -KAf^ 3Z7 E-mail:—
o
Bonding Company: N� Mortgage Lender: �`IA
Address: Address:to
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENTMAY RE'SUL'T' IN YOUR
PAYING TWICE FOR INIPROVEMENTS TO YOUR PROPER'T'Y. A NO'T'ICE OI' COAV IENCEMENT iNIUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. 1F YOU IN'T'END TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain it permit to do the work and installations tis indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be pertormed to meet standards of all laws regulating construction
in this jurisdiction. I understand that it separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tacks, and air conditioners, etc.
FBC 105.3 Shall he inscribed with the date of application and the code in effect as of that date: 511' Edition (2014) Florida Building Code
y (� �fltJ.Sj
Revised: June 30, 2015 I'ennil Application >licution
CONTACT INFORMATION:
ARCHITECT
KEESEE, ASSOCIATES
945 SOUTH ORANGE BLOSSOM TRAIL
APOPKA, FLORIDA 32703
AA 26003115
CONTACT NAME: JAMES A. GARRITANI, R.A.
TEL: 407-880-2333 x206
EMAIL: JAMES.GARRITANI@GOKEESEE.COM
MECHANICAL, ELECTRICAL, PLUMBING ENGINEER:
INGENUITY ENGINEERS, INC.
4798 NEW BROAD STREET, SUITE 300
ORLANDO, FL. 32814
407-398-6007
CONTACT: DANIEL CHAPMAN
EMAIL: dchapman(aingenuityei.com
qfVICINITY MAP
SCALE: NONE
DEVIANT WOLFE
BREWERY
121 WEST 1st STREET
SANFORD, FLORIDA
32771
INDEX
REVISION HISTORY
CV1 INDEX, BUILDING DATA
w
CV2 GENERAL NOTES AND SPECIFICATIONS
LIFE SAFETY
LSO LIFE SAFETY
ARCHITECTURAL
A2.0 DEMOLITION PLAN
A2.1 PROPOSED FLOOR PLAN
A2.2 PROPOSED SEATING PLAN
A3.0 REFLECTED CEILING PLAN
A6.0 DOOR AND WINDOW SCHEDULE
A6.1 ENLARGED PLANS
MECHANICAL
M0.1 MECH SPECS, LEGENDS, NOTES & ABBREV.
M2.1 MECHANICAL PLAN
M3.1 MECHANICAL SCHEDULES & DETAILS
ELECTRICAL
E0.1 ELEC SPECS, LEGENDS, NOTES & ABBREV.
E2.0 ELECTRICAL DEMO PLAN
E2.1 ELECTRICAL PLAN
E3.0 ELECTRICAL RISER AND PANEL SCHEDULE
PLUMBING
P0.1 PLUMB SPECS, LEGENDS, NOTES & ABBREV.
P1.0 PLUMBING SITE PLAN
P2.1 PLUMBING PLAN
OCCUPANCY CLASSIFICATION: EXIS-
GROUP - F-2 / A-2
OCCUPANCY - BREWERY / BAR
CONSTRUCTION TYPE: EXISTING
EXISTING - TYPE III -B - NON -SPRINKLED / UNPRO
OCCUPANT LOAD
BAR: 1,376 SQ. FT. / 15 = 91 PERSONS
BREWERY: 1,438 SQ. FT. / 100 = 14 PERSONS
OFFICE / STORAGE: 253 SQ. FT. / 300 = 1 PERSON
TOTAL: 3,064 SQ. FT. / 129 PERSONS
JURISDICTION
CITY OF SANFORD
(5) SETS
PERMItM
OFFICE
CD
Z 0
_0
z <0 Ll
z�
Q
C� z
,_n�
Q�
w
� o
.0 —
O c 0
V)
CO
U ��
Lu c'mM
2-gc')
000
Ap
CO
zv �CO
U
N o
O
0 O
Q rn rn Q o
le1 o. 4_111' � �!
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
LIJ
U.O
F_
z
Q
w
0
w
3:
w
0�m
T
N
W M
W Q
O
4-1J
T_LL
T
N 0
TLL
r�
V J
SHEET INFORMATION
DATE: 06/2612017
DRAWN BY: bwa
PROJECT NO: 16-2235
REVIEWED BY: JAG
1wI Plan Revisions Date: 1
.�ncci ivanic `+ f
-3- rI
IN X AND
BUILDING
DATA
Sheet No.
CV1
W
a
w
LIJ
U.O
F_
z
Q
w
0
w
3:
w
0�m
T
N
W M
W Q
O
4-1J
T_LL
T
N 0
TLL
r�
V J
SHEET INFORMATION
DATE: 06/2612017
DRAWN BY: bwa
PROJECT NO: 16-2235
REVIEWED BY: JAG
1wI Plan Revisions Date: 1
.�ncci ivanic `+ f
-3- rI
IN X AND
BUILDING
DATA
Sheet No.
CV1
W
a
FAA 111 =3 It
LEGEND OF SYMBOLS
SYMBOL
HGT.
HEIGHT
&
AND
H.C.
HANDICAPPED ACCESSIBLE
L
ANGLE
HM.
HOLLOW METAL
@
AT
HORZ.
HORIZONTAL (LY)
<
CENTERLINE
HB,
HOSE BIB
C
CHANNEL
HR.
HOUR
0
DIAMETER OR ROUND
INCL.
INCLUDING
1
PERPENDICULAR OR STRUCTURAL TEE
NEW C.M.U. WALL
SEE PARTITION TYPE/ WALL TYPE
--
#
NUMBER OR POUND
ID.
INSIDE DIAMETER
BRICK VENEER W/WO BASE WALL
SEE PARTITION -TYPE/ WALL TYPE
INSUL.
INSULATE (D) (ING) (TION)
ABV,
ABOVE
INT.
INTERIOR
ACOUS./ACT
ACOUSTICAL TILE
JB
JUNCTION BOX (ES)
ADJ.
ADJUSTABLE
JC
JANITORS CLOSET
A/C
AIR CONDITIONING
JCT.
JUNCTION
A.F.F.
ABOVE FINISHED FLOOR
JT.
JOINT
ALT.
ALTERNATE
L,
LENGTH
AL.
ALUMINUM
LAM.
LAMINATE (D)
ALUM,
ALUMINUM
LAV.
LAVATORY
A.S,T.M.
AMERICAN SOCIETY TESTING MATERIALS
A.I.S.C.
AMERICAN INSTITUTE OF STEEL CONSTRUCTION
LG.
LAMINATED GLASS
A.I.A.
AMERICAN INSTITUTE OF ARCHITECTS
LDG.
LEADED GLASS
AB,
ANCHOR BOLT
LL.
LIVE LOAD
ANDD.
ANODIZED
LT.WT,
LIGHT WEIGHT
ARCH.
ARCHITECT(URAL)
MANUF.
MANUFACTURE (ER)
A.R.
AS REQUIRED
MARE.
MARBLE
AUTO,
AUTOMATIC
MAS,
MASONRY
A.N.S.I.
AMERICAN NATIONAL STANDARDS INSTITUTE
M.O.
MASONRY OPENING
AWWM.
ALIGN WITH WINDOW MULLION
MAX,
MAXIMUM
BKSPL.
BACK SPLASH
MG,
MIRROR GLASS
BSMT.
BASEMENT
MIN,
MINIMUM
M/R
MOISTURE RESISTANT
BRG.
BEARING
BM.
BEAM
MTD.
MOUNTED
BTWN.
BETWEEN
MTL.
METAL
BIT.
BITUMINOUS
MECH.
MECHANIC (AL)
BLK.
BLOCK
MAT.
MATERIAL
BLKG.
BLOCKING
MISC.
MISCELLANEOUS
BD,
BOARD
NFPA.
NATIONAL FIRE PROTECTION AGENCY
BOT,
BOTTOM
N.
NORTH
BRK,
BRICK
NTS
NOT TO SCALE
NEC
NATL. ELECTRIC CODE
BLDG.
BUILDING
NSF
NATL. SANITATION FOUND.
BU.
BUILT-UP
CO.
CLEAN OUT
OSHA
OCCUPATIONAL SAFETY AND
HEALTH ADMINISTRATION
CPT.
CARPET (ED)
OC,
ON CENTER (S)
C.B.
CATCH BASIN
OPG.
OPENING
CTR.
CENTER
OA.
OVER ALL
CLG.
CEILING
OD.
OUTSIDE DIAMETER
C.F.C.I.
FURNISHED INSTALLED
O.F.0.1.
OWNER FURNISHED OWNER INSTALLED, (N.I.C.)
CEM.
CEMENT
O.F.C.I.
OWNER FURNISHED CONTRACTOR INSTALLED
C,T.
CERAMIC TILE
O.H.
OPPOSITE HAND
CHAM.
CHAMFER
OWG.
ONE WAY GLASS
CHN LNK
CHAIN LINK
PNT
PAINT
C.I,
CAST IRON
PTD.
PAPER TOWEL DISPENSER
C.I.P.
CAST IN PLACE
PL
PROPERTY LINE
CIR.
CIRCLE
PLAM
PLASTIC LAMINATE
CIRCUM.
CIRCUMFERENCE
PLYWD
PLYWOOD
CLR
CLEARANCE
P/CF
POUNDS PER CUBIC FOOT
COL
COLUMN
P/LF
POUNDS PER LINEAL FOOT
CONC
CONCRETE
PISF
POUNDS PER SQUARE FOOT
CMU
CONCRETE MASONRY UNIT
PSI
POUNDS PER SQUARE INCH
CONST.
CONSTRUCTION
PT.
POINT
CONTR.
CONTRACTOR
P.T.
PRESSURE TREATED
CONT.
CONTINUOUS OR CONTINUE
RAD.
RADIUS
CJT
CONTROL JOINT
RE:
REFERENCE OR SEE
CTPG
CLEAR TEMPERED PLATE GLASS
REF.
REFERENCE
CTR
COUNTER
REINF.
REINFORCING
CW
COLD WATER
REQ'D.
REQUIRED
DCD
CASE DRAIN
REV.
REVISION (S) (REVISED)
D,F,
DRINKING WATER FOUNTAIN
RO
ROUGH OPENING
DTL
DETAIL
RAW
RIGHT OF WAY
DIA
DIAMETER
SCH,
SCHEDULE
DIM
DIMENSION
SHT,
SHEET
DS
DOWN SPOUT
SC
SOLID CORE
DWG
DRAWING
S.
SOUTH
DL
DOWN LEADER
SSBC
SOUTHERN STANDARD BUILDING CODE (S)
DN
DOWN
SPEC.
SPECIFICATION (S)
EA.
EAST
S.S.
STAINLESS STEEL
E
EACH
S/S
SANITARY SEWER
E.H,D.
ELECTRIC HAND DRYER
SPG
SPANDRELITE PANEL GLASS
ELEC
ELECTRIC
STD
STANDARD
EL
ELEVATION
STL.
STEEL
ELEV
ELEVATION
STOR
STORAGE
EQ.
EQUAL
STRUCT
STRUCTURAL
E.W,
EACH WAY
SUSP.
SUSPENDED
E.W.C.
ELECTRIC WATER COOLER
T & B
TOP AND BOTTOM
E.W.H.
ELECTRIC WATER HEATER
T.M.
TO MATCH
EXH.
EXHAUST
T.M.E.
TO MATCH EXISTING
EJJT/ E,J,
EXPANSION JOINT
T.O.C.
TOP OF CONCRETE
EXP.
EXPOSED
TOH.
TOTAL DYNAMIC HEAD
EXIST./EXTG,
EXISTING
T.O.M.
TOP OF MASONRY
EXT.
EXTERIOR
T.O.R.F.
TOP OP ROOF PERIMETER
FA
FIRE ALARM
T.O.R.D.
TOP OF ROOF DECK
FE.
FIRE EXTINGUISHER
T.O.W.
TOP OF WALL
F.CLG/ FIN. CEIL.
FINISH CEILING
TTPG
TINTED TEMPERED PLATE GLASS
F.F./ FIN. FL
FINISH FLOOR
T. OF F.
TOP OF FOUNDATION
FIN,
FINISH (ED)
TEL.
TELEPHONE
FLASH.
FLASHING
TV.
TELEVISION
FLR.
FLOOR (ING)
T & G.
TONGUE AND GROOVE
FLUOR
FLUORESCENT
TYP.
TYPICAL
FOC.
FACE OF CONCRETE
U.N.O.
UNLESS NOTED OTHERWISE
FOF
FACE OF FINISH
V.B.
VAPOR BARRIER
FOFM
FACE OF FINISHED MASONRY
VERT.
VERTICAL
VCT.
VINYL COMPOSITION TILE
FOS.
FACE OF STUDS
F.O.SH.
FACE OF SHEATHING
VP
VENEER PLASTER
VTR.
VENT THRU ROOFW/
F.O.S,M.
FACE OF STRUCTURAL MASONRY
WITH
FTG.
FOOTING
W.
WIDTH OR WEST
FT,
FOOT
WC.
WATER CLOSET
GALV.
GALVANIZED
W. HTR.
WATER HEATER
G.I.
GALVANIZED IRON
WNDW
WINDOW
GD.
GRADE (GRADING)
WO
WITHOUT
GEN.
GENERAL
WD
WOOD
GYP./GWB
GYPSUM WALL BOARD
WG
WIRE GLASS
H OR HT.
HEIGHT
WT.
WEIGHT
HDW.
HARDWARE
WP.
WATER PROOFING
HDR.
HEADER
WWF.
WELDED WIRE FABRIC
HVAC.
HEATING/VENTILATING/
AIR CONDITIONING
LEGEND OF SYMBOLS
SYMBOL
DESCRIPTION
rgg N 0
NORTH ARROW
ROOM NAME
0000SQFT
302
ROOM NAME & NUMBER - SEE FINISH SCHEDULE
�ooa
DOOR NUMBER - SEE DOOR SCHEDULE
��---
COLUMN GRID REFERENCE
P-01
PARTITION TYPE - SEE SHEET A6.1
EL. 30'-3"
TOP OF BEAM
ELEVATION MARK
A
D n� B
INTERIOR ELEVATION MARK
®
PLAN NOTE NUMBER
O#
LOUVER MARK - SEE SHEET
3
REVISION MARK
ErDETAIL
MARK
INSULATION
- T -
LINES OF CEILING CHANGES
( SOFFITS, OVERHANGS ETC.)
NEW C.M.U. WALL
SEE PARTITION TYPE/ WALL TYPE
--
METAL STUD WALLS
SEE PARTITION TYPE/ WALL TYPE
METAL STUD WALL W! INSULATION
SEE PARTITION TYPE/ WALL TYPE
BRICK VENEER W/WO BASE WALL
SEE PARTITION -TYPE/ WALL TYPE
CONCRETE
STUCCO, PLASTER OR G.W.B.
r -
BRICK/ BLOCK ELEVATION
= I I=1 { I=1 I I=
III=1 11=1 I I =1 I I-1 I
-III--III-III-III-
III=1 I I=1 I I=1 I I=1 I
-i 1=T"i i=1T1=T=
GRADE / EARTH
BUILDING SECTION MARK
WALL SECTION MARK
DETAIL MARK
* NOTE: SPECIFIC DETAILS MAY CONTAIN SYMBOLS
FOR MATERIALS THAT DIFFER FROM
THESE GENERAL ITEMS NOTED.
PROJECT REQUIREMENTS AND COMPLIANCE PROJECT NOTES
zm
0
z
1. CODE REQUIREMENTS: IT IS THE INTENT THAT ALL WORK SHALL CONFORM TO THE ADOPTED CODES, STANDARDS AND RULES OF THE 1. The Specification, Ideas, Designs, and Arrangements represented herein are and shall remain the
roe of the Designer and no part thereof shall be copied, disclosed to others or used in connection <
ADMINISTRATIVE AUTHORITY HAVING JURISDICTION P P rfY 9 P
with any work or project other than the specified project for which they have been prepared and I
2. ALL WORK SHALL CONFORM WITH DRAWINGS AND SPECIFICATIONS IN ACCORDANCE WITH THE REQUIREMENTS OF ALL THE FOLLOWING WHERE developed without written consent. Visual contact with these plans or specifications shall constitute CL
APPLICABLE: -
conclusive evidence of acceptance of these restrictions.
(A) GOVERNING MUNICIPAL AND REGULATORY AGENCIES 2. The Contractor shall verify all conditions and dimensions and report any discrepancies to the
(B) LOCAL, STATE AND FEDERAL BODIES Owner prior to beginning work. Contractors shall verify and be responsible for all dimensions and
conditions on the Job and this office must be notified of any variation from the dimensions and
APPLICABLE CODES : conditions shown by these drawings. Ga
3. The plans show the location of all fixtures and equipment and are intended to convey the general ro
STANDARD FLORIDA BUILDING CODE 2014 5th EDITION intent of the work in scope and layout. They are not intended to show in minute detail every and all • ® LU
STANDARD FLORIDA PLUMBING CODE 2014 5th EDITION accessories intended for the purpose of execution of the work, but is understood that such details are to c U)
pari of this work. � o 0
STANDARD FLORIDA MECHANICAL CODE 2014 5th EDITION 4. No work is to be installed prior to the submission and approval of appropriate and required shop
STANDARD FLORIDA FUEL GAS CODE 2014 5th EDITION drawings, samples, etc. as described in the contract documents. w
5. The Contractor is responsible for providing a complete and finished product. Any items not ~ o` o 0
NFPA 70 NATIONAL ELECTRIC CODE 2011 NEC specified, or identified, but required to complete an assembly, system, etc. shall be considered part of T � u_ W
FA to
FLORIDA FIRE PREVENTION CODE: 2014 5TH EDITION AND CURRENT ADOPTED CODES & this contract. I (J N
6. The Contractors shall coordinate and assure themselves that all items of work will fit and function in Y o
STANDARDS BY THE STATE OF FLORIDA < 0, d) ¢ .o
accordance with the intent of (hese documents and that individual pieces of the same and different
NFPA 1 AND NFPA 101 FLORIDA EDITION: 2012 EDITION systems will properly function in conformance with the Manufacturer and Industry Standard
N•C•II•D•C
FLORIDA ACCESSIBILITY CODE 2014 5th EDITION requirements.
7. The Contractor shall be responsible for all damage, inside or outside the limit of work due to
EXISTING FLORIDA BUILDING CODE 2014 5th EDITION operations. The Contractor shall restore all damaged areas or items to their original condition at no °
additional cost to the Owner. The Contractor shall provide all temporary protection as required to
property secure the building from intruders, animals, and the elements. THIS DOCUMENT AND/OR THE DESIGN
8. The Contractor shall be responsible for an existing material or stem integrated with scope of CONCEPTS EXPRESSED HEREIN ARE THE
P y g y g p PROPERTY OF KEESEE ASSOCIATES AND
3. THE GENERAL CONTRACTOR SHALL COMPLY WITH ALL THE REQUIREMENTS OF THE SOILS REPORT. OBTAIN FROM THE OWNER THE CURRENT work for conformance with the contract documents and objectives of this project. All clearances and ALL RIGHTS OF OWNERSHIP, INCLUDING
COPY OF THE SOILS INVESTIGATION REPORT IF NECESSARY. conflicts of any and all construction; Framing/ Mechanical/ Plumbing/ Electricall etc required shall be COPYRIGHT OF INTELLECTUAL PROPERTY,
adjusted for proper fit, accessibility and function. ARE RESERVED THE REPRODUCTIONS,
4. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES BY THE GENERAL CONTRACTOR AND ALL AREAS SHALL BE LEFT IN A CLEAN CONDITION ATCOPYING, OR USE OF THIS DOCUMENT
9, The Contractor shall be responsible for the coordination of all trades not identified, indicated or AND/OR THE DESIGN CONCEPT WITHOUT
ALL TIMES DURING CONSTRUCTION. described in the drawings. Individual Contractors shall be responsible for the conformance of their THE WRITTEN CONSENT OF KEESEE
5. IT IS UNDERSTOOD THAT ALL INTENDED WORK IS SUBJECT TO REVIEW AND INTERPRETATION BY THE ADMINISTRATIVE AUTHORITY HAVING design and execution to all applicable Local, State and Federal Building Codes and Ordinances, Zoning ASSOCIATES IS STRICTLY PROHIBITED AND
JURISDICTION. IN NO CASE SHALL WORK BE PERFORMED WITHOUT THE REVIEW AND WRITTEN APPROVAL OF SAID AUTHORITY. Bylaws and Governing Agencies as well as OSHA, NFPA and the Health Acts. The Contractor shall PROTECTED BY UNITED STATES AND
coordinate all N.I.C., Owner supplied, and furnished items as required. INTERNATIONAL LAW.
10. The Contractor shall work in a clean, organized, and professional manner and shall be responsible
6. ALL TRADES SHALL BE RESPONSIBLE FOR ALL FEES RELATED TO THE ISSUE OF TRADE -SPECIFIC PERMITS, INSPECTIONS AND CERTIFICATES for maintaining the safety and security of the site during construction.
NECESSARY FOR THE EXECUTION AND COMPLETION OF THE WORK, AND THE OCCUPANCY OF THE WORK. 1R
11. The Contractor shall be responsible for the removal of trash from the site, on a weekly basis, at a
7. EXISTING CONDITIONS: THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND FIELD -COORDINATE THE CORRECTIVE ACTION AS REQUIRED. minimum, and maintain a safe and orderly condition.1. _/
THE GENERAL CONTRACTOR SHALL NOTIFYTHE ARCH ITECTIDESI GNER OF ALL CONFLICTS AND DISCREPANCIES THAT AFFECT THE WORK PRIOR 12, Materials specified are for configuration, quality, and performance. Demonstrated equals will be ' O
TO PROCEEDING WITH SAID WORK. amenable and acceptable with Owner's written approval (unless otherwise noted in contract documents. w� :• �.\� rf S
14. Coordinate all dimensions orequipment and built in items with final placement locations
8. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS WILL GOVERN. LARGE-SCALE DRAWINGS SHALL GOVERN OVER SMALLER -SCALED DRAWINGS.
CONTACT ARCHITECTIDESIGNER TO CONFIRM ALL DISCREPANCIES, as -built conditions. ,
15. All material shall be installed in strict accordance with manufacturers specifications and related (D CD
CO
9. THE ARCHITECT/DESIGNER SHALL NOT BE HELD RESPONSIBLE FOR WORK PERFORMED NOT IN ACCORDANCE WITH THESE DOCUMENTS NOR FOR trade practices or standards. The preparations and modifications of underlying conditions shall be , S
�. '
MISINTERPRETATION OF THE DRAWINGS, NOR FOR UNSATISFACTORY WORK BY CONTRACTOR. complete and ready for the next trade or product. All work shall be in conformance with good trade
practice and performed by skilled workers, trained in the installation of the product being installed.
10. CONFIRM ALL HORIZONTAL DIMENSIONS WITH PLANS AND IN FIELD PRIOR TO FABRICATION AND/OR CONSTRUCTION Work not conforming to these requirements shall be cause for rejection. Satisfactory remedies may , r�
11. ALL ELECTRICAL AND MECHANICAL INFORMATION CONTAINED IN THESE DRAWINGS IS SOLELY FOR THE PURPOSE OF COORDINATION OF THE involve complete removal and replacement of defective work or material at the contractors expense .
ARCHITECT/DESIGNER'S WORK, 16. General Contractor shall be responsible for all required drawings, calculations and diagrams for
plumbing, mechanical and electrical permits and to install required components to meet all applicable
codes.
®N NOTES 17, General Contractor shall be responsible for all required drawings, calculations, diagrams and
TERMITE P R®TE CTI
certification for contractor supplied systems for required permitting and as required to meet
all applicable codes.
SOIL CHEMICAL BARRIER METHOD '18. In the event of a conflict with items or systems specified or detailed in more than one location, the
1. "A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE -INSPECTION AND TREATMENT CONTRACT contractor shall provide the more expensive or higher quality item at no cost to the owner.
RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR WATER HEATER OR ELECTRICAL PANEL." FBC 104.2.6 19. The Contractor is advised that the Owner and other Contractors may be performing work during
the performance of his work. Complete cooperation and coordination is required.
2. "CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST V-13" AWAY FROM BUILDING SIDE WALLS." FBC 1503.4.4 20. Any Contractor, Subcontractor, Individual, Company, or their designees performing work or
3. "IRRIGATION / SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN V-0" OF BUILDING SIDE services for this project, be it for materials, labor or both shall be responsible for the detailed
WALLS." FBC 1503.4.4 examination of existing conditions at the site, as indicated in drawings, or in other information available
4. "TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAN from a Public Agency or Utility Company. No consideration shall be given for claims made as a result UJ
6 INCHES." of failure to understand, identify or establish existing conditions. Any damage to existing shall be the y _
responsibility of the Contractor and repaired at his own expense.
EXCEPTION: PAINT OR DECORATIVE CEMENTIUUS FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY TO THE FOUNDATION WALL. FBC 1403.1.6 resp
LL
21. The Contractor shall supply all items identified to be provided in the specifications or the drawing I�
5. "INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE." FBC 1816.1.1 independent of being indicated within the other. �I
6. "SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED OR FORMED." FBC 1816.1.2CO
22. Provide steel trowel finish at all beam details, window sills and upper roof and column caps unless 0 ^00UJ
7. "BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUIENT INSTALLATION OF TRAPS, ETC„ noted otherwise. W SHALL BE MADE WITH PERMANENT METAL OR ELECTRICAL ADDITIONAL NOTE;
PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL
TREATMENT," FBC 1816.1.3 23. Contractor to provide'Utiliguard System' Energy Management Systems or approved equal on all UJ(�
8. "MINIMUN 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAIN FALL DILUTION. IF RAIN FALL OCCURS BEFORE VAPOR electrical power panels for energy/green systems. U) 0
RETARDER PLACEMENT, RETREAT AS REQUIRED." FBC 1816.1.4 GENERAL NOTES
9. "CONCRETE OVERPOUR AND MORTAR ALONG FOUNDATION PERIMETER MUST BE REMOVED BEFORE EXTERIOR SOIL TREATMENT." FBC 0 LL1816.1.5 T_1. The contractor shall visit the site prior to preparation of his bid and thoroughly familiarize himself with conditions of
10. "SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN V-0" OF THE STRUCTURE SIDEWALLS," FBC the construction area and work required to perform the work of this contract. Obtain dimensions by calculation, Z UJ
1816.1.6 DO NOT SCALE THE DRAWINGS . If dimensions are in question, the contractor shall request clarification from the (�
11. "AN EXTERIOR VERTICAL CHEMICAL BERRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND architect prior to continuing construction of the area in question.
IRRIGATION. ANY SOIL DISTURBED AFTER THE CHEMICAL BERRIER IS APPLIED, SHALL BE RETREATED," FBC 1816.1.6N U. o
2. This building has been designed in accordance with section 1606 of the 2014 Florida Building Code. j L
12. "ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT." FBC 1816.1.7 3. All dimension are taken from face of masonry or stud unless noted otherwise. LU
13. "A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENCED PEST CONTROL COMPANY BE FOR 4. All conduit, piping, and ductwork penetrating any rated assembly; floor, ceiling or wall shall Q
CERTIFICATE OF OCCUPANCY WILL BE ISSUED, THE CERTIFICATE OF COMPLIANCE SHALL STATE:'THE BUILDING HAS RECEIVED A COMPLETE have an approved fire rated assembly for the specific application.
TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS OF THE 5. All mechanical and electrical equipment shall be located on site per architectural or civil drawings. UJ
FLORIDA BUILDING DEPARTMENT OF AGRICULTURE AND CUSTOMER SERVICES." FBC 1816.1.7 6. All lumber in contact with the soil, concrete, masonry, or as indicated or required shall be pressure
preservative treated.
14. "AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW WITHIN V-0" OF THE BUILDING. THIS INCLUDES 7. All exterior steel stud construction shall be minimum 20 gage with a maximum spacing of 24" o.c.
ALL GRADE STAKES, TUB TRAP BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL." FBC 2303.1.3 All interior steel stud construction shall be minimum 25 gage with a maximum spacing of 24" o.c.
with no exception
15. "NO WOOD, VEGITATION, STUMPS, CARDBOARD, TRASH, ETC,, SHALL BE BURIED WITHIN 15"0 OF ANY BUILDING OR PROPOSED BUILDING." 8. At all perimeter storefront window framing provide closed end flat pocket filler
FBC 2303.1.4 9 At all perimeter storefront frame assemblies provide min. I" shim, Storefront to be cleaned of all foreign debris,
i.e, stucco, prior to sealant application.
10. High performance storefront window sill to be extruded aluminum with closed end pan.
11. See floor plans and reflected ceiling plans for specific elevations and details.
12. Install thresholds at all exterior doors, at fire rated doors, and doors between air conditioned &
non air conditioned spaces and where materials change on either side, z
13. All soffit systems, roof systems and window systems to meet all uplift and shape criteria as required by codes.
14. Specifications and requirements indicated on structural , mechanical, plumbing and 2
electrical drawings are considered minimum acceptable criteria and may be superceded by more
stringent criteria required as part of architectural documents. Contractor shall notify the Architect SHEET INFORMATION
for any possible conflicts or discrepancies prior to commencing the specific work. DATE, 0612612017
15. Not used DRAWN BY, bwa
16. Contractor to coordinate and verify all exterior wall control and expansion joints prior to the PROJECT NO: 16-2235
commencement of specific work.
17. All glass to be tempered per code adjacent to doors, etc.. REVIEWED BY: JAG
18. Provide durarock tile backer board @ all locations scheduled for tile finish ® Plan Revisions Date:
19. Provide vinyl base @ all walls unless otherwise specified/noted.
1
20. Provide casing beads @ all stucco and drywall transitions to different material. Provide sealant 2
joint w/ backer rod or bondTireak. Typical unless noted otherwise.
21. Provide corner beads @ all stucco & drywall returns. 3
22. Extend all non bearing walls to 4" above finish ceiling unless noted otherwise 4
23. Provide control joints between different construction types. Le. metal framing and C.I.P. or C.M.U. 5
construction. 6
24. All finishes shall be protected where indicated as final finish. The Contractor shall be responsible for all v
repairs to produce a uniform finish.
25. Provide steel trowel finish at all beam details, window sills and upper roof and column caps unless noted 8
otherwise. Sheet Name
26. Exterior paint - 2 color locations - to be determined by Architect/Owner,
27. ARCHITECT SHALL BE INDEMNIFIED, HELD HARMLESS FOR ANY HURT, LOSS, OR DAMAGE DUE TO ANY AND e
ALL OWNER FINISH SELECTIONS.
LEGENDS
AND NOTED
Sheet No.
0
ASTM A563DH HEAVY HEX
NUT (GALVANIZED) & F436
WASHER (GALVANIZED)—
C10x20 (GALVAN
1
Y2" STEEL
BOTTOM PL.
I
I
11/2" I APPROX.12"
I (FIELD VERIFY)
I
11
REMOVE EXIST. FURRED OUT WALL TO
INSTALL PROPOSED C10 SNUG AGAINST
BRICK STRUCTURAL WALL (TYP, EA. SIDE)
3/" O ASTM A449 THRU-BOLTS
(GALVANIZED) - SEE FRAMING
ELEVATION FOR SPACING AND
LOCATIONS
10x20 (GALVANIZED)
1/4"
1/4"
EXIST. BRICK
WALL (BEYOND)
2 12" CONT. EA.
2 END (TYP.)
FRAMING SECTION @ NEW OPENING
SCALE: 1 1/2" = 1'4"
T/ GVICT
10'-0"
(PROPOSED M.O. - VERIFY)
FRAMING ELEVATION @ NEW OPENING
SCALE: 1/2" = 1'-0"
PROPOSED FLOOR PLAN
SCALE: 1/4" = 1'- 0"
:_w... _.. T..I 1.
LEGEND
Door See 1/A7.0
Q
Window See 2/A75.0
-�
Wall Types
Insulated PreFab Walk-in Cooler
WALL TYPES LEGEND
Existing Exterior Masonry Wall
Existing Interior CMU Wall to 10'-0" HGT
Insulated PreFab Walk-in Cooler
3 5/8" Metal Stud Framing
PLAN NOTE:
1. ALL NEW INTERIOR WALLS ARE METAL STUD WITH DRYWALL OR TILE BACKER
BOARD UNLESS NOTED OTHERWISE,
2, ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE
TYPICAL AND SHALL BE CONSTRUCTED TO APPLY TO ANY SIMILAR SITUATION
ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN.
3, ARCHITECT SHALL BE INDEMNIFIED, HELD HARMLESS FOR ANY HURT, LOSS, OR
DAMAGE DUE TO ANY AND ALL OWNER FINISH SELECTIONS.
4. SUBMIT CASEWORK, DOORSMARDWARE SHOP DRAWINGS FOR
OWNER/ARCHITECT APPROVAL,
5, CONFIRM ALL HORIZONTAL DIMENSIONS W/ PLANS AND IN FIELD PRIOR TO
FABRICATION/CONSTRUCTION.
6• ALL INTERIOR AND EXTERIOR FINISHES AS SELECTED BY OWNER.
7, ALL ELECTRICAL FIXTURESIEQUIPMENT, PLUMBING FIXTURES/EQUIPMENT AND
HVAC EQUIPMENT AS SELECTED & APPROVED BY OWNERIARCHITECT.
8. 1/8" PER FOOT SLOPE TO FLOOR DRAINS -TYPICAL
DIMENSION NOTE:
1. DO NOT SCALE DRAWINGS.
2. ALL DIMENSIONS ARE STUD TO STUD TO CMU.
ADA NOTE:
1. SEE INTERIOR ELEVATIONS AND ADA PLAN FOR
ALL ADA INFORMATION
INTERIOR FINISHES:
1. ALL ROOMS TO HAVE CERAMIC TILE, PAINTED GYPSUM BOARD,
VINYL BASE, AND LAY -IN CEILING. COORDINATE PAINT COLORS
AND TILE SELECTION WITH GC
2. CHAIR RAILING TO BE INSTALLED IN WAITING AREA AT 36" A.F.F.
3, COORDINATE ALL CABINET AND MILL WORK WITH GC
jk 6'-0" A.F.F.
TILE WAI
AT RESTRt
11 3 5/8" (OR 6") METAL STUDS @ 16"
luw\fllul- O.C. W/ 5/8" GYPSUM BOARD BOTH
SIDES,
O BOTTOM PLATE ANCHORED @ 16"
O.C.(2x P.T. AT WET AREAS)
SEE ROOM FINISH SCHEDULE
FOR FLOOR FINISH AND BASE
ALTERNATE WALL PARTITION
3 5/8" OR 6" METAL STUDS @ 16"
O.C. (OR BRG. WALL: SEE STRUCT
DWGS FOR LOCATIONS) W/ 5/8"
GYPSUM BOARD BOTH SIDES, FILL
W/ SOUND DEADENING INSUL.
BOTTOM PLATE ANCHORED @ 16"
O.C.(2x P.T. AT WET AREAS)
SEE ROOM FINISH SCHEDULE
FOR FLOOR FINISH AND BASE
TYPICAL WALL PARTITION
P -i
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
LU
C
w
Uj
a
w
W
U
�o
a`
SHEET INFORMATION
DATE: 07/26/2017
DRAWN BY: bwa
PROJECT NO: 16-2235
REVIEWED BY: JAG
® Plan Revisions Date: '
1 07/26/17:PERMIT COMMENT RESPONSE
2
3
4
5
6
7
8
Sheet Name
Sheet No.
A2. 1
WOOD DOOR
/-CASING
DOOR HARDWARE
REF: SCHEDULE Q
F. F.
FLUSH WOOD DOOR
(STYLE PER OWNER)
A
HOLLOW METAL -
CASING
DOOR HARDWARE
REF: SCHEDULE `LL
HOLLOW METAL
INSULATED
HOLLOW METAL EXTERIOR
B
'-0" V.I.F.
DOOR/ WINDOW NOTE:
1. ALL EXTERIOR DOORS TO MEET WIND LOAD CRITERIA.
2. ALL GROUND FLOOR UNIT HARDWARE @ ENTRY DOORS
SHALL MEET ALL CODES, LAWS AND GUIDELINES FOR
HANDICAP ACCESSIBILITY
3. THRESHOLDS AT EXTERIOR DOORS, INCLUDING SLIDING
GLASS DOOR TRACKS, ARE NO HIGHER THAN 1 INCH.
THRESHOLDS AND CHANGES IN LEVEL AT THESE
LOCATIONS ARE BEVELED WITH SLOPES NO GREATER
THAN 1:12
DOOR SCHEDULE TYPICAL GENERAL NOTES
1. FRAMES ARE TYPICALLY WRAPAROUND;
SET EXTERIOR FRAMES AS DETAILED.
2. ALL GLASS LIGHTS IN DOORS AND FRAMES SHALL BE
TEMPERED UNLESS NOTED AS LABELED; ALL GLASS
LIGHTS IN LABELED DOORS AND FRAMES SHALL BE
CLEAR FIREGLAS 20 BY TGP OR EQUAL
3. ALL EXT. FRAMES SHALL BE GROUTED FULL.
4. ALL DOORS 13/4" THICK; ALL FRAMES TO HAVE 518"
X 13/4" RABBETS EACH SIDE, VARY STOP WIDTHS
TO ACCOMMODATE CLEAR THROAT DIMENSIONS INDICATED.
5. ALL DOOR AND FRAME LABELS SHALL BE METAL (RIVET
OR SCREW ATTACHED). STICK -ON LABELS NOT ACCEPTABLE;
PROTECT LABELS FROM BOTH PRIMERS AND FINISH PAINTING.
LABELS SHALL BE BRIGHT EMBOSSED METAL PER NFPA 80.
THRESHOLDS
1. ALUMINUM (EXT.)
2. TRANSITION STRIP
3. CONTINUE FLOORING UNDER DOOR
DOOR SCHEDULE REMARKS LEGEND
1. 90 MIN. FIRE RATED DOOR
2.18"X24" LOUVER
3. UNDERCUT DOORS 3/4" MINIMUM
4. CONTINUE FLOOR MATERIAL UNDER DOOR
5. CONTINUE DRYWALL ABOUT DOOR JAMB, PROVIDE
CORNER BEAD ALL ABOUT
6. CONTRACTOR TO VERIFY EXISTING DOOR SIZE/ROUGH OPENING
7. CONC. FILLER TO PROVIDE SILL NOT REQUIRED
8.12" x 12" LOUVER
9. PEMKO 2211APK DOOR BOTTOM W/DRIP SHOE
1 -LITE
TEMPERED
GLAZING
DOOR HARDWARE
REF: SCHEDULE
ALUMINUM STOREFRONT
C
ROOL-UP INDUSTRIAL DOOR
< D >
DOOR TYPES
SCALE: 1/4" = V-0"
BREWERY GATE
E
ROOM FINISH SCHEDULE NOTE:
ALL FINISHES ARE CLASS "B" MIN. FOR FLAME SPREAD
ROOM No.
ROOM DESCRIPTION
DOOR SCHEDULE
BASE
WALL FINISH
MARK
�1
DOOR
TYPE
FRAME
TYPE
BUILDERS
HW
GROUP
DOOR SIZE
TAP ROOM
DETAILS
RATING
THRESHOLD
GWB
REMARKS
HEAD
JAMB
SILL
101
C
SF
1 -ED
3'-0"x6'-8"
102
""
--
-
-
EXISTING
MFR
102
C
SF
1 -ED
3'-0"x6'-8"
PAINTED DRYWALL/ EXPOSED BRICK
-
-
--
-
-
EXISTING
VINYL
103
B
MTL
1 -ED
3'-0"x6'-8"
WOMEN'S RESTROOM
ST. CONC
VINYL
--
-
-
EXISTING
106
104
D
ALUM
-
10'-0"=10'-0"
9'4"
'-
""
-'
-
-
NEW - ROOL-UP : INSULATED
105
E
WD/MTL
1 -LS
(2) 3'-0"x4'-0"
--
-
--
-
NEW
106
A
WOOD
1 -PS
3'-0"x6'-8"
H1
11
--
-
-
NEW
107
A
WOOD
1 -PS
3'-Q"x6'-8"
H1
11
'-
-
-
NEq- FULL SWING ni
108
B
MTL
1 -LS
3'-0"x6'-8"
""
"'
-
-
EXIST
109
E
WD/MTL
1 -LS
3'-0"x4'-0"
-
-'
-
NEW
HARDWARE GROUPS
HARDWARE
GROUP
ITEM
QUANTITY
STYLE/TYPE
STYLE/TYPE
MANUF.
LOCK SET
1
LEVER
BRUSHED ALUM.
SCHLAGE
1
CLOSER
1
900 SWING
BRUSHED ALUM.
LNC
STOPS
1
FLOOR MOUNTED
BRUSHED ALUM.
IVES
BUTTS
1\ PAIR
5 -KNUCKLE
S. STEEL
STANLEY
LS - LOCK SET - SCHLAGE
PR - PRIVACY - SCHLAGE
PS - PASSAGE - SCHLAGE
ED - EXIT DEVICE - VON PUPRIN
WOOD DOOR
/-CASING
DOOR HARDWARE
REF: SCHEDULE Q
F. F.
FLUSH WOOD DOOR
(STYLE PER OWNER)
A
HOLLOW METAL -
CASING
DOOR HARDWARE
REF: SCHEDULE `LL
HOLLOW METAL
INSULATED
HOLLOW METAL EXTERIOR
B
'-0" V.I.F.
DOOR/ WINDOW NOTE:
1. ALL EXTERIOR DOORS TO MEET WIND LOAD CRITERIA.
2. ALL GROUND FLOOR UNIT HARDWARE @ ENTRY DOORS
SHALL MEET ALL CODES, LAWS AND GUIDELINES FOR
HANDICAP ACCESSIBILITY
3. THRESHOLDS AT EXTERIOR DOORS, INCLUDING SLIDING
GLASS DOOR TRACKS, ARE NO HIGHER THAN 1 INCH.
THRESHOLDS AND CHANGES IN LEVEL AT THESE
LOCATIONS ARE BEVELED WITH SLOPES NO GREATER
THAN 1:12
DOOR SCHEDULE TYPICAL GENERAL NOTES
1. FRAMES ARE TYPICALLY WRAPAROUND;
SET EXTERIOR FRAMES AS DETAILED.
2. ALL GLASS LIGHTS IN DOORS AND FRAMES SHALL BE
TEMPERED UNLESS NOTED AS LABELED; ALL GLASS
LIGHTS IN LABELED DOORS AND FRAMES SHALL BE
CLEAR FIREGLAS 20 BY TGP OR EQUAL
3. ALL EXT. FRAMES SHALL BE GROUTED FULL.
4. ALL DOORS 13/4" THICK; ALL FRAMES TO HAVE 518"
X 13/4" RABBETS EACH SIDE, VARY STOP WIDTHS
TO ACCOMMODATE CLEAR THROAT DIMENSIONS INDICATED.
5. ALL DOOR AND FRAME LABELS SHALL BE METAL (RIVET
OR SCREW ATTACHED). STICK -ON LABELS NOT ACCEPTABLE;
PROTECT LABELS FROM BOTH PRIMERS AND FINISH PAINTING.
LABELS SHALL BE BRIGHT EMBOSSED METAL PER NFPA 80.
THRESHOLDS
1. ALUMINUM (EXT.)
2. TRANSITION STRIP
3. CONTINUE FLOORING UNDER DOOR
DOOR SCHEDULE REMARKS LEGEND
1. 90 MIN. FIRE RATED DOOR
2.18"X24" LOUVER
3. UNDERCUT DOORS 3/4" MINIMUM
4. CONTINUE FLOOR MATERIAL UNDER DOOR
5. CONTINUE DRYWALL ABOUT DOOR JAMB, PROVIDE
CORNER BEAD ALL ABOUT
6. CONTRACTOR TO VERIFY EXISTING DOOR SIZE/ROUGH OPENING
7. CONC. FILLER TO PROVIDE SILL NOT REQUIRED
8.12" x 12" LOUVER
9. PEMKO 2211APK DOOR BOTTOM W/DRIP SHOE
1 -LITE
TEMPERED
GLAZING
DOOR HARDWARE
REF: SCHEDULE
ALUMINUM STOREFRONT
C
ROOL-UP INDUSTRIAL DOOR
< D >
DOOR TYPES
SCALE: 1/4" = V-0"
BREWERY GATE
E
ROOM FINISH SCHEDULE NOTE:
ALL FINISHES ARE CLASS "B" MIN. FOR FLAME SPREAD
ROOM No.
ROOM DESCRIPTION
FLR
BASE
WALL FINISH
CLG.
L .
REMARKS
100
TAP ROOM
ST. CONC
VINYL
PAINTED DRYWALL/ EXPOSED BRICK
GWB
EXISTING
101
BAR
ST. CONC
VINYL
PAINTED DRYWALL/ EXPOSED BRICK
GWB
EXISTING
102
COLD STORAGE
MFR
MFR
MFR
MFR
WALK-IN COOLER
103
BREWING
ST. CONC
VINYL
PAINTED DRYWALL/ EXPOSED BRICK
GWB
EXISTING
104
OFFICE / STORAGE
ST. CONC
VINYL
PAINTED DRYWALL
GWB
EXISTING
105
WOMEN'S RESTROOM
ST. CONC
VINYL
TILE WAINSCOT TO 6'4"/ PAINTED DRYWALL ABV.
GWB
9'-0"
106
MEN'S RESTROOM
ST, CONC
VINYL
TILE WAINSCOT TO 6'-0"/ PAINTED DRYWALL ABV.
GWB
9'4"
FACE OF CMU BEYOND
DOOR
INTERIOR
CONCRETE SLAB
DOOR BOTTOM
THRESHOLD
METAL STUD METAL STUD BEVEL 1:2
FRAMING FRAMING
GYP. BD. GYP. BD. EXTERIOR
WOOD DOOR CONCRETE �CAS I N G
WALK ^ T'N
METAL STUD _
HEADER L p
d
WOOD DOOR p a
CASING
DOOR, SEELEXPANSION JOINT
DOUBLE METAL DOOR, SEE
SCHEDULE STUD SCHEDULE MATERIOR
DOOR HEADER DETAIL I JAMB DETAIL(OYHOLD
DOOR THRES
H SCALE: 1-1/2" = 1'-0" `� SCALE: 1-1/2" = 1'-0" SCALE. s - 1 -0
C SLOTTED "BRITE" ALUMINUM
CHANNEL AT EACH END,
TOP AND BOTTOM
STEEL SUPPORT
T
RECLAIMED RUSTIC
WOOD PANEL
STAINED CONC. FLOOR
C 0
EXIST. CONCRETE SLAB
POUH-ROCK
3' DIA.
BREWERY BARRIER WALL
SCALE: 1-1/2" = V-0"
PLEXIGLASS COUNTER TOP
W/ CLEAR SEALANT AT
EDGES AND SEAMS
2"x7xl /1 A" BRUSHED STEEL 31-011
ANGLE OVER CLEAR
SEALANT. SCREW TO
BARTOP
ACCESS PANEL AS REQ'D
W/ HINGE AT BOTTOM
AND CLASP AT TOP.
CUT OPENINGS IN BARTOP
op
FOR DISPLAY BOXES.
SEE PLAN FOR EXTENTS.
II II
II II
t
II II
II II
BASE CABINET/SHELVES II
t t
II II
U ll
&__BAR
SECTION
SCALE : l" = 1'-0"
a
0
RECLAIMED WOOD
BARTOP OVER 1/2"
PLYWOOD BACKING
OVERHANGS THAT
o. EXCEED 12" MAY REQUIRE
A SUPPORT BRACKET
RECLAIMED WOOD
SIDING
2x FRAMING
N
1/2" GYPSUM
2x P.T. FOOT STEP
FRAMING
2x P.T. SOLE PLATE
L
rvYc�n�o�c
®0
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
co
��®C <•
— T
• DO i M
w ; o
ctz
Z
LuwLu
In
E
IL
SHEET INFORMATION
DATE: 07126/2017
DRAWN BY: bwa
PROJECT NO: 16-2235
REVIEWED BY: JAG
® Plan Revisions Date:
1 07/26/17:PERMIT COMMENT RESPONSE
Sheet Name
DOOR
AND
WINDOW
SCHEDS.
Sheet No.
A6.0
FOR DISPLAY BOXES.
SEE PLAN FOR EXTENTS.
II II
II II
t
II II
II II
BASE CABINET/SHELVES II
t t
II II
U ll
&__BAR
SECTION
SCALE : l" = 1'-0"
a
0
RECLAIMED WOOD
BARTOP OVER 1/2"
PLYWOOD BACKING
OVERHANGS THAT
o. EXCEED 12" MAY REQUIRE
A SUPPORT BRACKET
RECLAIMED WOOD
SIDING
2x FRAMING
N
1/2" GYPSUM
2x P.T. FOOT STEP
FRAMING
2x P.T. SOLE PLATE
L
rvYc�n�o�c
®0
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
co
��®C <•
— T
• DO i M
w ; o
ctz
Z
LuwLu
In
E
IL
SHEET INFORMATION
DATE: 07126/2017
DRAWN BY: bwa
PROJECT NO: 16-2235
REVIEWED BY: JAG
® Plan Revisions Date:
1 07/26/17:PERMIT COMMENT RESPONSE
Sheet Name
DOOR
AND
WINDOW
SCHEDS.
Sheet No.
A6.0
MECHANICAL LEGEND ABBREVIATIONS
ABV ABOVE
SUPPLY DIFFUSER. ARROWS INDICATE 1 WAY, 2 WAY, ADJ ADJUSTABLE
OR 3 WAY. NO ARROWS INDICATE 4—WAY.
AF AIRFOIL
AFF ABOVE FINISHED FLOOR
AP ACCESS PANEL
CEILING MOUNTED EXHAUST FAN BI BACKWARD INCLINE
BHP BRAKE HORSEPOWER
SUPPLY DUCT UP SECTION (RECTANGULAR) BTUH BRITISH THERMAL UNIT PER HOUR
CD CONDENSATE DRAIN
CFM CUBIC FEET PER MINUTE
RETURN DUCT UP SECTION (RECTANGULAR) CLO CEILING
COND CONDENSATE
COP COEFFICIENT OF PERFORMANCE
EXHAUST DUCT UP SECTION (RECTANGULAR) DB DRYBULB
DWGS DRAWINGS
DX DIRECT EXPANSION
SUPPLY DUCT DOWN SECTION (RECTANGULAR)
EF EXHAUST FAN
EXH EXHAUST
RETURN DUCT DOWN SECTION (RECTANGULAR) EA EACH
EAT ENTERING AIR TEMPERATURE
ELECT ELECTRICAL
EXHAUST DUCT DOWN SECTION (RECTANGULAR) ENT ENTERING
EQ EQUAL
EWT ENTERING WATER TEMPERATURE
SUPPLY DUCT UP SECTION (ROUND). FC FORWARD CURVED
FL FLOOR
SUPPLY DUCT DOWN SECTION (ROUND). FLEX FLEXIBLE CONNECTOR OR DUCT
FPM FEET PER MINUTE
FT. HD. FEET OF HEAD
RECTANGULAR DUCTWORK WITH TAKE—OFF, BALANCING 'F DEGREES FAHRENHEIT
A B DAMPER AND INSULATED FLEXIBLE ROUND DUCT. SAME CA GAUGE
SIZE AS DIFFUSER INLET UNLESS NOTED OTHERWISE, GAL GALLON
FIRST DIMENSION IS THAT OF SIDE SHOWN.
GALV GALVANIZED
A ROUND DUCTWORK. HP HORSEPOWER
CONICAL FITTING WITH DAMPER ON BRANCH KW KILOWATTS
CONNECTION TO RECTANGULAR MAIN MAX MAXIMUM
(PROVIDE DAMPER IN LOW PRESSURE DUCTWORK ONLY).
MBH 1000 X BTUH
MIN MINIMUM
EXISTING DUCTWORK TO REMAIN
N.T.S. NOT TO SCALE
{—� OA OUTSIDE AIR
PCT PERCENT
VOLUME DAMPER.
PD PRESSURE DROP
PERF. PL. PERFORATED PLATE
AIR DEVICE TAG
A-100 MARK—CFM PLBG PLUMBING
PSIA POUNDS PER SQUARE INCH
ABSOLUTE
01 EXISTING SIDEWALL SUPPLY REGISTER PSIG POUNDS PER SQUARE INCH
GAUGE
(T WALL MOUNTED THERMOSTAT RA RETURN AIR
MOUNT 4'-0" ABOVE FINISHED FLOOR. REG REGISTER
®R REFERENCE NOTES REQ'D REQUIRED
RG RETURN AIR GRILLE
INDICATES POINT OF CONNECTION BETWEEN NEW RH RELATIVE HUMIDITY
AND EXISTING.
RPM REVOLUTIONS PER MINUTE
® POINT OF DISCONNECT RTU ROOFTOP UNIT
SA SUPPLY AIR
EQUIPMENT
AH TYPE EQUIPMENT TAG SF SUPPLY FAN
MARK SDT SMOKE DETECTOR
SD SUPPLY DIFFUSER
a 1" DOOR UNDER CUT. ARROW INDICATES DIRECTION SDMP SMOKE DAMPER
UC OF FLOW SQ,FT, SQUARE FOOT
STIR STARTER
TEMP TEMPERATURE
T'STAT THERMOSTAT
TYP TYPICAL
UC UNDERCUT (DOOR)
VFDC VARIABLE FREQUENCY DRIVE
CONTROLLER
VAV VARIABLE AIR VOLUME
VS VARIABLE SPEED
W WATTS
WB WETBULB
MECHANICAL SPECIFICATIONS
GENERAL
CA# 26308 I17094.00
4798 NEW BROAD STREET
SUITE 300
ORLANDO, FL 32814
407.398.6007 (P)
407.398.6003 (F)
3 as
�r1
meers, 1ne.
SUBSTITUTIONS:,
Lo_...�
0
THE GENERAL MECHANICAL SPECIFICATIONS APPLY TO THE WORK SPECIFIED IN THIS SECTION. PROVIDE
(D
INSTALL DUCTWORK INDICATED ON DRAWINGS, MAKING NECESSARY CHANGES IN CROSS—SECTIONS AND
ALL LABOR, MATERIALS, SERVICES, EQUIPMENT AND APPLIANCES REQUIRED FOR THE FABRICATION,
EQUIPMENT AND DESIGN OF SYSTEMS INDICATED ON THE DRAWINGS AND WITHIN THESE SPECIFICATIONS
OFFSETS, WHETHER OR NOT SPECIFICALLY INDICATED.
INSTALLATION, AND/OR RENOVATION OF MECHANICAL SYSTEMS INCLUDING HEATING, VENTILATING, AIR
SHALL BE CONSIDERED AS "STANDARD OF QUALITY". NO SUBSTITUTIONS SHALL BE MADE WITHOUT PRIOR
I
CONDITIONING AND MISCELLANEOUS SYSTEMS AS INDICATED IN DESIGN DRAWINGS AND AS OUTLINED IN
WRITTEN APPROVAL OF THE ENGINEER. ALL EQUIPMENT SHALL BE NEW UNLESS OTHERWISE NOTED, FREE
EITCHEN EXHAUST DUCTWORK:
THESE SPECIFICATIONS.
OF DEFECTS, AS SHOWN ON THE DRAWINGS OR INDICATED IN SPECIFICATIONS.
E
)
O
V I
N M
FABRICATE IN ACCORDANCE WITH SMACNA STANDARDS AND NFPA 96. CONSTRUCT OF 16 GAUGE
SCOPE OF WORK:
DEVIATIONS FROM SPECIFIED EQUIPMENT AFFECTING ELECTRICAL REQUIREMENTS SHALL BE COORDINATEDGALVANIZED
STEEL OR 18 GAUGE STAINLESS STEEL, USING CONTINUOUS EXTERNAL WELDED JOINTS.
(D
yi ���d.$.a'
a
Z11 "INN;
7 . Y
BETWEEN VENDOR, MECHANICAL CONTRACTOR, AND ELECTRICAL CONTRACTOR PRIOR TO SUBMITTING BIDS.
SUPPORTS SHALL BE 16 GAUGE MINIMUM GALVANIZED STEEL WHERE CONCEALED AND OF 18 GAUGE
FURNISH AND INSTALL COMPLETE AIR CONDITIONING SYSTEMS AS INDICATED ON THE DESIGN DRAWINGS
FAILURE TO DO SO WILL NOT BE CAUSE FOR CHANGE OF BID AT A LATER TIME. IN ADDITION, THE
MINIMUM STAINLESS STEEL WHERE EXPOSED. SLOPE DUCT TOWARD HOOD A MINIMUM OF " PER FOOT
AND AS OUTLINED WITHIN THESE SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO THE
MECHANICAL CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR ANY AND ALL CHANGES TO
OF RUN (1" PER FOOT IF OVER 75'). PROVIDE ACCESS DOORS WHERE REQUIRED BY CODES FOR
FABRICATION AND/OR INSTALLATION OF THE SCHEDULED AIR CONDITIONING UNITS, EXHAUST FANS, AIR
ENGINEERING PLANS REQUIRED BY AUTHORITY HAVING JURISDICTION.
CLEANING AND INSPECTION OF DUCT.
DISTRIBUTION AND DUCTWORK.
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
APPLICABLE CODES/STANDARDS:
PROVIDE ACCESS DOORS WITH GREASE CLEANOUT AND CEILING ACCESS FOR ALL CHANGES IN DIRECTION
CLEANING, TESTING AND ADJUSTING:
INTERNATIONAL LAW.
AND EVERY 20' OF DUCT RUN.
THE MECHANICAL CONTRACTOR, AT HIS EXPENSE, SHALL CLEAN, REPAIR, ADJUST, CHECK, BALANCE, AND
— 2014 FLORIDA BUILDING CODE (FBC)
\Id,6tjV�
PLACE IN SERVICE 'THE VARIOUS SYSTEMS HEREIN SPECIFIED WITH 'THEIR RESPECTIVE EQUIPMENT,
— 2014 FLORIDA MECHANICAL CODE (FMC)
ELBOWS SHALL BE LONG (1.5R) OR SHORT (1R) RADIUS, MITERED ELBOWS ARE NOT ACCEPTABLE. DUCT
ACCESSORIES AND PIPING. HE SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, AND TOOLS
— 2014 FLORIDA PLUMBING CODE (FPC)
JOINTS SHALL BE BUTT JOINTS OR OVERLAPPING DUCT JOINTS OF EITHER TELESCOPING OR BELL TYPE
REQUIRED TO PERFORM TESTS REQUIRED BY THESE SPECIFICATIONS AND BY THE GOVERNING
— 2014 FLORIDA ENERGY CODE (FEC)
(OVERLAP SHALL NOT EXCEED 2").
AUTHORITIES.
— NFPA LATEST EDITION
[jj i�
U)a
— SMACNA DUCT CONSTRUCTION STANDARDS
SHEET METAL DUCT CONNECTION TO HOODS JOINTS SHALL BE MADE WITH A CONTINUOUS EXTERNAL
NO WORK SHALL BE COVERED OR CONCEALED UNTIL PROPERLY INSPECTED AND TESTED.
— ASHRAE
LIQUID TIGHT WELD. MANUFACTURER TO PROVIDE LITERATURE FOR GASKET MATERIALS TO BE USED WHEN
TESTING:
— 2011 NATIONAL ELECTRIC CODE (NEC)
APPLICABLE.
ADJUST THE AIR CONDITIONING SYSTEMS, VENTILATING SYSTEMS, FANS, ETC., TO DELIVER NOT LESS
THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, INSPECTIONS AND PAY ALL FEES.
ACCESS DOORS:
THAN THE REQUIRED AIR QUANTITY WITH QUANTITIES IN EXCESS TO BE SUBJECT TO THE APPROVAL OF
SHOP DRAWINGS AND SUBMITTALS:
CONTRACTOR SHALL PROVIDE HINGED ACCESS DOORS FOR DAMPERS, VALVES, ETC. WHERE FLOORS,
THE ENGINEER IF FOUND TO NOT HAVE OBJECTIONABLE EFFECTS SUCH AS NOISE, DRAFTS, OR MOTOR
DATE: 0612612017
WALLS, AND CEILINGS MUST BE PENETRATED TO ACCESS MECHANICAL SYSTEMS. FINISH SHALL BE
OVERLOAD.
SUBMIT SHOP DRAWINGS AND MANUFACTURER'S DATA FOR ALL NEW EQUIPMENT FOR ENGINEER'S APPROVAL PRIOR
COORDINATED THROUGH ARCHITECT TO MATCH SURROUNDING FINISHES.
PRIOR APPROVAL BY THE ENGINEER OF TESTING AND BALANCING CONTRACTOR IS REQUIRED. THIS
TO PURCHASE AND/OR FABRICATION. SHOP DRAWINGS FOR EQUIPMENT REQUIRING ELECTRIC POWER OR CONTROL
3
CONTRACTOR SHALL PROVIDE THREE (3) COPIES OF A TEST AND BALANCE REPORT TO THE ENGINEER
WIRING SHALL INCLUDE COMPLETE WIRING DIAGRAMS,
FURNISH IN DUCTWORK AS INDICATED AND WHEREVER NECESSARY FOR PROPER ACCESS TO ALL
7
0 I E DAMPERS MOTORIZED DAMPERS AND EQUIPMENT FO V
FIRE
INSTRUMENTS, CONTROLS, F RR CONVENIENT
AT TIME OF SUBSTANTIAL COMPLETION INSPECTION. THE REPORT SHALL BE PREPARED BY A
HVAC CONTRACTORS SHALL SUBMIT COMPLETE DUCTWORK SHOP DRAWINGS FOR REVIEW BY THE
INSPECTION, MAINTENANCE AND REPLACEMENT OF SAME. SIZE SHALL BE AMPLE FOR USAGE. OPENINGS
CONTRACTOR CERTIFIED BY ASSOCIATED AIR BALANCE COUNCIL OR NATIONAL ENVIRONMENTAL BALANCING
ENGINEER. SHOP DRAWINGS SHALL INCLUDE COORDINATION WITH GENERAL CONTRACTOR REGARDING
SHALL BE REINFORCED ON ALL SIDES WITH MATERIAL OR DUCTWORK IN WHICH DOORS ARE INSTALLED.
BUREAU.
EXACT OPENINGS REQUIRED IN EXTERIOR WALLS. THE DUCTWORK SHOP DRAWINGS WILL ONLY BE
REVIEWED FOR COMPLIANCE WITH DRAWINGS AND SPECIFICATIONS. DRAWINGS WILL NOT BE CHECKED FORH
HARDWARE - USE VENT LOK HARDWARE THROUGHOUT. ALL DOORS TO BE HINGED WITH BRASS PIN
T RA
THE TEST AND BALANCE REPORT SHALL BE TYPEWRITTEN AND CONTAIN THE FOLLOWING DATA:
COORDINATION WITH OTHER TRADES OR BUILDINGS STRUCTURE. IT IS "THE RESPONSIBILITY OF THE
HINGES AND WITH QUICK OPENING LATCHES AS FOLLOWS:
CONTRACTORS TO COORDINATE AND VERIFY ROUTING AND EXACT LOCATION OF SYSTEM COMPONENTS.
1. REACH -IN DOORS TO BE 18" HIGH.
1. DATE, TIME, WEATHER, WHEN TEST TAKEN.
2. TWO #150 HINGES WITH ROOF FANS, RELIEF VENTS, AIR INTAKES, AND CURBS.
2. AIR CAPACITIES AT EACH UNIT INCLUDING OUTSIDE AIR. (ENTERING AND LEAVING DB/WB)
SYSTEM IDENTIFICATION:
3. STATIC PRESSURE THROUGH UNITS AND UNIT COMPONENTS.
INSULATION:
4. MOTOR OPERATING VOLTAGE AND AMPERAGE.
PROVIDE IDENTIFICATION LABELS ON OR NEAR EACH PIECE OF MAJOR EQUIPMENT AND EACH OPERATION
5. DRIVE TYPES, SIZES AND SPEED RANGE.
DEVICE AND DISCONNECT. LABELS SHALL BE CONSTRUCTED OF ENGRAVED PLASTIC LAMINATE SIGN OR
SHALL BE AS MANUFACTURED BY CERTAINTEED, OWENS-CORNING, MANVILLE, PITTSBURGH CORNING,
6. IDENTIFICATION OF ALL AIR TERMINAL DEVICES WITH DESIGN CFM AND ACTUAL CFM.
PLASTIC EQUIPMENT MARKER PERMANENTLY SECURED TO EQUIPMENT, LETTERING SHALL BE A MINIMUM
ARMSTRONG, OR APPROVED EQUAL. INSULATION SUNDRIES AND ADHESIVES SHALL BE AS MANUFACTURED
OF 1/2 INCH HIGH FOR EQUIPMENT NAME AND 3/8 INCH HIGH FOR EQUIPMENT INFORMATION.
BY BENJAMIN FOSTER, CHILDERS, VIMASCO, OR APPROVED EQUAL. ALL INSULATION SHALL BE SUITABLE
ADDITIONALLY, SYSTEMS DRAWING CLEARLY MARKED TO IDENTIFY LOCATION OF EQUIPMENT AND AIR
FOR INSTALLATION IN A RETURN AIR PLENUM.
DEVICES TESTED SHALL BE PROVIDED ALONG WITH THE WRITTEN TEST AND BALANCE REPORT.
VALVES SHALL BE TAGGED USING PLASTIC LAMINATE TAGS SECURED WITH BRASS CHAINS INDICATING THE
VALVE SIZE, SERVICE AND FUNCTION.
INSULATE ALL SHEETMETAL DUCTWORK EXCEPT EXHAUST DUCTWORK EXTERNALLY WITH MANVILLE R
MAINTENANCE MANUALS
SERIES MICROLITE TYPE 75 OR 100 INSULATION OR APPROVED. INSULATION TO HAVE TYPE 11 FSK
FACING AND UL FIRE HAZARD CLASSIFICATION OF FLAME SPREAD 25/SMOKE DEVELOPED 50/FUEL
PROVIDE COMPLETE MAINTENANCE MANUALS (3 REQUIRED) ON ALL NEW EQUIPMENT. ORGANIZE
CONTRIBUTED 50. INSTALL INSULATION PER SMACNA, FLORIDA MODEL ENERGY EFFICIENCY CODE AND
OPERATING AND MAINTENANCE DATA INTO SUITABLE. SETS OF MANAGEABLE SIZE. BIND PROPERLY
MANUFACTURER'S
MANUFACTURER'S RECOMMENDATIONS. ALL INSULATION JOINTS SHALL BE SEALED WITH GLASS FABRIC
INDEXED DATA INTO INDIVIDUAL, HEAVY-DUTY, 2 -INCH, 3 -RING VINYL COVERED BINDERS WITH POCKET
ALL LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC., INDICATED ON THE DRAWINGS IS DIAGRAMMATIC
AND MASTIC.
FOLDERS FOR FOLDED SHEET INFORMATION. MARK APPROPRIATE IDENTIFICATION ON FRONT AND SPINE
AND SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE TO THE PLANS SUBJECT TO BUILDING
OF EACH BINDER. INCLUDE THE FOLLOWING TYPES OF INFORMATION. THE INFORMATION WILL BE
CONSTRUCTION AND INTERFERENCES WITH OTHER TRADES. CONTRACTOR IS RESPONSIBLE FOR ANY FIELD
MINIMUM INSULATION REQUIREMENTS AS FOLLOWS:
TURNED OVER TO THE OWNER AT TIME OF SUBSTANTIAL COMPLETION:
MEASUREMENTS REQUIRED TO PROVIDE AN APPROVED AND FUNCTIONAL INSTALLATION.
- SUPPLY AND RETURN AIR UNCONDITIONED: 2" (R-6 MIN)
- OPERATING AND MAINTENANCE INSTRUCTIONS-
COORDINATE WITH OTHER TRADES AND FIELD -VERIFY EXISTING CONDITIONS FOR EXACT LOCATION AND
OUTSIDE AIR: 2" (R-6 MIN)
- SPARE PARTS LIST
- COPIES WARRANTIES
ROUTING OF SYSTEMS. PROVIDE OFFSETS, TRANSITIONS AND ADAPTORS AS REQUIRED.
CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ADEQUATE AND PROPER
- A
WIRING DIAGRAMS
NOT ALL COMPONENTS REQUIRED FOR A COMPLETE INSTALLATION ARE SHOWN ON THESE DRAWINGS.
INSULATION AND MOISTURE -SEAL IN A MANNER THAT WILL PERMANENTLY PREVENT THE ACCUMULATION
OF ANY OBJECTIONABLE MOISTURE ON THE EXTERIOR OF AIR CONDITIONING UNITS, REFRIGERANT PIPING,
- INSPECTION REPORTS AND APPROVALS
REFER TO EQUIPMENT INSTALLATION INSTRUCTION, SCHEDULES AND APPLICABLE CODES FOR ADDITIONAL
CONDENSATE DRAIN PIPING, AIR DUCTS OR OTHER PARTS OF THE SYSTEM. CONTRACTOR SHALL
SHOP DRAWINGS AND PRODUCT DATA
- TEST AND BALANCE INFORMATION
INFORMATION, INCLUDING REQUIRED CONNECTION LOCATIONS, TYPES AND SIZES.
CORRECT THE CAUSE OF ANY CONDENSATION AND FULLY REPAIR, WITHOUT COST TO THE OWNER, ANY
DAMAGES TO BUILDING SURFACES, FURNISHINGS OR EQUIPMENT CAUSED BY CONDENSATION FROM THIS
TRAINING SERVICES
PERFORM ALL WORK NECESSARY TO PREPARE THE STRUCTURE FOR THE INSTALLATION OF THE WORK.
SYSTEM, FOR THE FULL PERIOD OF GUARANTEE.
ALL HOLES, OPENINGS AND DAMAGED MATERIALS CREATED DURING CONSTRUCTION SHALL BE REPAIRED.
ALL PENETRATIONS SHALL BE SLEEVED AND SEALED SO AS TO BE WATER AND AIR TIGHT.
CONTROLS:
THOROUGHLY INSTRUCT THE OWNER'S REPRESENTATIVE IN THE OPERATION OF ALL EQUIPMENT
FURNISHED AND LOCATION OF ALL VALVES AND CONTROL DEVICES.
VIBRATION ISOLATION:
FACTORY MOUNTED CONTROL SHALL BE PROVIDED TO ACCOMPLISH THE SEQUENCE OF OPERATION. ALL
TRAIN BUILDING OWNER'S PERSONNEL DURING NORMAL WORKING HOURS ON STARTUP AND SHUTDOWN
ALL BLOWER UNITS AND VIBRATING TYPE EQUIPMENT SHALL BE PROPERLY FITTED WITH MASON
INTERIOR CONTROLS SHALL BE FACTORY FURNISHED AND INSTALLED.
PROCEDURES, TROUBLESHOOTING PROCEDURES, SERVICING AND PREVENTATIVE MAINTENANCE SCHEDULE
INDUSTRIES VIBRATION ISOLATION EQUIPMENT SIZED IN ACCORDANCE WITH EQUIPMENT WEIGHT AND DUTY.
PROVIDE ALL 24 VOLT WIRING BETWEEN CONTROL DEVICES AS NECESSARY TO MAKE COMPLETE AND
AND PROCEDURES. REVIEW WITH THE OWNER'S PERSONNEL, THE DATA CONTAINED IN THE OPERATING
OPERATION SYSTEM. PROVIDE 110/24 VAC 'TRANSFORMERS AS REQUIRED. COORDINATE WITH DIVISION 16
AND MAINTENANCE MANUALS. SCHEDULE TRAINING WITH OWNER, PROVIDE AT LEAST 7 -DAYS PRIOR
PROVIDE FLEXIBLE CONNECTORS AT ALL SUPPLY AND RETURN CONNECTIONS TO AIR HANDLING
FOR 120V POWER ROUGH -IN, CONTROL, POWER AND WIRING. 24 VOLT WIRING SHALL BE PLENUM RATED
NOTICE TO ARCHITECT/ENGINEER.
EQUIPMENT CONSISTING OF HEAVY CANVAS OR NEOPRENE FABRIC WITH AIRTIGHT SEAMS AND
CABLE.
CONNECTIONS TO THE EQUIPMENT.
HANGERS AND SUPPORTS
EQUIPMENT:
DUCTWORK:
PROVIDE ALL NECESSARY HANGER RODS, CLAMPS AND ATTACHMENTS TO PROPERLY INSTALL AND
INSTALL DUCT SMOKE DETECTORS FURNISHED BY DIVISION 16 IN SUPPLY AIR DUCTS OF AIR HANDLING
SUPPORT DUCTWORK, PIPING AND EQUIPMENT FROM THE BUILDING STRUCTURE.
ALL DIMENSIONS ARE INSIDE NET FREE AREA.
UNITS EXCEEDING 2000 CFM AND WHERE INDICATED ON DRAWINGS. DETECTOR TO SHUT DOWN WHEN
PROVIDE ANY ANGLE IRON OR UNISTRUT AND SUSPENSION RODS REQUIRED TO INSTALL EQUIPMENT,
MATERIALS: LOW PRESSURE SUPPLY AND RETURN DUCTWORK SHALL BE FIBERBOARD EQUAL TO
ACTIVATED.
PIPING AND DUCTWORK.
MANSVILLE FR -800 (SUPERDUCT). PROVIDE MINIMUM "R" VALUE OF 4.2 FOR DUCTS INSTALLED IN
EXHAUST FANS:
CONDITIONED SPACE AND 6.0 FOR DUCT INSTALLED IN UNCONDITIONED SPACE. DUCTWORK SHALL BE
ALL SUPPORTS EXPOSED TO OUTDOORS SHALL BE CLEANED, PRIMED AND PAINTED TO PREVENT
LINED WITH ANTI MICROBIAL COATING. SEAL ALL JOINTS WITH GLASS FABRIC AND MASTIC. TAPE ALONE
FURNISH EXHAUST FANS WITH PERFORMANCE AND CAPACITIES AS LISTED ON THE DESIGN DRAWINGS.
RUSTING. FINISH COLOR AS SELECTED BY OWNER.
IS NOT ALLOWED.
ROOF CURBS:
THE USE OF BALING WIRE OR PERFORATED METAL STRAPPING IS NOT ACCEPTABLE FOR SUPPORTS.
GENERAL EXHAUST DUCTS SHALL BE GALVANIZED OR STAINLESS STEEL SHEET METAL.
SIZE AS REQUIRED TO ACCOMMODATE EXHAUST FANS AND RELIEF VENTS. TO BE FURNISHED BY
MANUFACTURER OF EQUIPMENT TO BE MOUNTED. ROOF CURBS SHALL MATCH ROOFING 'TYPE AND
WARRANTY/GUARANTEE:
WET EXHAUST DUCTS SHALL BE ALUMINUM OR STAINLESS STEEL SHEET METAL.
SLOPTHE
CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS
ADJUSTABLE SPLITTERS AND DAMPERS SHALL BE INSTALLED IN EVERY SPLIT AND BRANCH DUCT AND
COORDINATE WITH ARCHITECT TO LOCATE EXHAUST FANS, EXHAUST GRILLES, WALL OR ROOF CAPS A
AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE (1) YEAR.
SHALL BE PROVIDED WITH LOCKING QUADRANTS ON EXPOSED OR IN ACCESSIBLE AREAS OF THE DUCT
MINIMUM DISTANCE OF 10'-0" FROM ANY OPERABLE WINDOW, DOOR OR FRESH AIR INTAKE.
FOR EASE OF OPERATION. ACCESS PANELS OR YOUNG REGULATORS SHALL BE PROVIDED WHERE
DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED
DAMPERS ARE INSTALLED ABOVE HARD CEILINGS OR IN SOFFITS.
AIR DISTRIBUTION EQUIPMENT:
PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE
SATISFACTION OF THE OWNER AND. ARCHITECT AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS
ELBOWS OR CHANGES IN DUCT DIRECTION GREATER THAN 45 DEGREES SHALL BE FITTED WITH AIR
FURNISH SUPPLY AIR GRILLES AND RETURN AIR REGISTERS WITH OPPOSED BLADE BALANCING DAMPERS
SHALL INCLUDE ALL DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE
TURNS CONSISTING OF CURVED AIRFOIL BLADES OR VANES WHICH WILL PERMIT THE AIR TO MAKE
"TURBULENCE.
AS SCHEDULED ON THE DESIGN DRAWINGS.
ORIGINAL DEFECT OR REPAIRS THERETO.
ABRUPT TURNS WITHOUT APPRECIABLE
FLEXIBLE DUCTWORK SHALL BE ACOUSTICAL LOW PRESSURE TYPE WITH INTERIOR LINER, METAL HELIX,
GRILLES, REGISTERS, AND CEILING DIFFUSERS SHALL BE FURNISHED AS SCHEDULED ON THE DESIGN
FIBERGLASS INSULATION WITH AN R -VALUE OF 6.0 OR GREATER, AND COPOLYMER SEAMLESS OUTSIDE
DRAWINGS AND SHALL BE ALL ALUMINUM CONSTRUCTION UNLESS NOTED OTHERWISE. AIR DISTRIBUTION
SLEEVE. THE ENTIRE FLEXIBLE DUCT ASSEMBLY SHALL BE LISTED IN ACCORDANCE WITH UL -181 CLASS
SHALL NOT EXCEED NC -30 NOISE CRITERIA AS DEFINED IN THE LATEST ASHRAE GUIDE.
1 AIR DUCT MATERIAL. THE MAXIMUM LENGTH OF ANY FLEX DUCT SHALL BE 7'-0". FLEXIBLE
DUCTWORK SHALL MEET THE FLORIDA MODEL ENERGY EFFICIENCY CODE. ALL JOINTS AT CONNECTIONS
TO DIFFUSERS AND DUCTWORK SHALL BE SEALED WITH GLASS FABRIC AND MASTIC.
CA# 26308 I17094.00
4798 NEW BROAD STREET
SUITE 300
ORLANDO, FL 32814
407.398.6007 (P)
407.398.6003 (F)
3 as
�r1
meers, 1ne.
Sheet No.
m
Lo_...�
0
(D
Y
z
I
..—�
cra
Lu
Ou.,
f -
V
E
)
O
V I
N M
.)
3.—
CLS u
o oti
M
LLI
x�—� 0
V
cu V)
O o
(D
yi ���d.$.a'
a
Z11 "INN;
7 . Y
U-
CO
o V
«
'"+, 0
U7
0-
Q O
aa4i4
'i
_
I VVV i
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
Cl)S 111 /,,
• • � Jr w o'
E � � (�
•°•
CCC...CCC���"' o �(✓ ' N
�, � o
�o
\Id,6tjV�
a
s&/O
" N AL ®��```
1111III� '
Lu
N
0 Lu
LL W
[jj i�
U)a
LL
r
z Lu
LjL T-0
Cil
L.
LLj U)
Li
cncn
Q
Q
E
z
Q
w
:o
a
SHEET INFORMATION
DATE: 0612612017
DRAWN BY: DMA
PROJECT NO: 16-2235
REVIEWED BY: MH
V Plan Revisions Date:
1
2
3
4
5
6
7
i8
mr-uHANICAL
SPECS,
LEGEND,
NO
A B V !
Sheet No.
m
X
LU
EN * • . '4
M2.1 1/4" = V-0"
MECHANICAL PLAN
114" 11-011
O REFERENCE NOTES
O1 SUPPLY DUCT ROUTED IN ATTIC SPACE.
(D INSTALL ION GENERATOR IN VERTICAL.
Q REUSE EXISTING OPENING AND CONNECT NEW RV -1 ON ROOF.
FIELD COORDINATE EXACT LOCATION.
O SLOPE EXHAUST DUCT 1/8" PER FOOT.
�5 8" DOWN TO BREW -KETTLE CONNECTION.
® 24"X18" LOUVER SIMILAR TO GREENHECK EVH-501 D.
7O EXISTING DOOR IS AN OLD BANK VAULT DOOR TO BE
PERMANENTLY LOCKED TO PREVENT FROM CLOSING. DOOR
WILL ALWAYS BE OPEN.
CA# 26308 I17094.00
4796 NEW BROAD STREET
SUITE 300
ORLANDO, FL 32814
407.398.6007 (P)
d ,407.398.6003 (F)
� nroxGve cnJ n<��ia7 S9?L4;W)i"
Inungl ii7luraws, inc.
(D `r'
o
_c)
Z'0
10
cy .y..
41
< h
V) (_}
LJJ
• U — 'ro
O 'L'
v o0
(i win
L.4J ar (1)gh�W E l0 C9
O N
LL CO
co
� O �
Nil
w epi`la�
+ Gdf (nn O (U
„,.r Q o
I
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
�.
Lu
u4t a r,•a � �
•� �t� � '� n
" • cb. O d
n
Q
w
E
z
w
O
4
SHEET INRORMA110N
DATE: 06/26/2017
DRAWN BY: DBA
PROJECT NO: 16-2235
REVIEWED BY. JBH
vrl Plan Revisions Dater
Sheet Name
MECHMN11CAL
PLAN
TAP
Room
l
I
O REFERENCE NOTES
O1 SUPPLY DUCT ROUTED IN ATTIC SPACE.
(D INSTALL ION GENERATOR IN VERTICAL.
Q REUSE EXISTING OPENING AND CONNECT NEW RV -1 ON ROOF.
FIELD COORDINATE EXACT LOCATION.
O SLOPE EXHAUST DUCT 1/8" PER FOOT.
�5 8" DOWN TO BREW -KETTLE CONNECTION.
® 24"X18" LOUVER SIMILAR TO GREENHECK EVH-501 D.
7O EXISTING DOOR IS AN OLD BANK VAULT DOOR TO BE
PERMANENTLY LOCKED TO PREVENT FROM CLOSING. DOOR
WILL ALWAYS BE OPEN.
CA# 26308 I17094.00
4796 NEW BROAD STREET
SUITE 300
ORLANDO, FL 32814
407.398.6007 (P)
d ,407.398.6003 (F)
� nroxGve cnJ n<��ia7 S9?L4;W)i"
Inungl ii7luraws, inc.
(D `r'
o
_c)
Z'0
10
cy .y..
41
< h
V) (_}
LJJ
• U — 'ro
O 'L'
v o0
(i win
L.4J ar (1)gh�W E l0 C9
O N
LL CO
co
� O �
Nil
w epi`la�
+ Gdf (nn O (U
„,.r Q o
I
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
�.
Lu
u4t a r,•a � �
•� �t� � '� n
" • cb. O d
n
Q
w
E
z
w
O
4
SHEET INRORMA110N
DATE: 06/26/2017
DRAWN BY: DBA
PROJECT NO: 16-2235
REVIEWED BY. JBH
vrl Plan Revisions Dater
Sheet Name
MECHMN11CAL
PLAN
E1-2, G1-4,
..A -CFM
AIR DEVICE
SCHEDULE
RANGE
I NECK SIZE
DRIVE TYPE E.S.P.
MARK
DESCRIPTION
FACE SIZE
NECK
MATERIAL
BASIS OF DESIGN
MANUFACTURER/MODEL #
DAMPER
NOTES
- 205
600
8Is0
206
- 375
146
10"o
376
A
LOUVERED FACE 2 CONE ADJUSTABLE SUPPLY DIFFUSER
24"x24"
SEE TABLE BELOW
ALUMINUM
METAL AIRE 5700 -AL
Y
1, 2, 3
B
LOUVERED FACE 2 CONE ADJUSTABLE SUPPLY DIFFUSER
12"x12"
SEE TABLE BELOW
ALUMINUM
METAL AIRE 5700 -AL
Y
1, 2, 3
F
SIDEWALL/CEILING 45' DEFLECTION RETURN GRILLE
NOTE 4
SEE TABLE BELOW
ALUMINUM
METAL AIRE RH
Y
1, 2, 5
X
EXISTING DIFFUSER OR EXISTING GRILLE
-
-
-
-
SHOWN
-
NOTES:
1. COORDINATE COLOR AND SURFACE FINISHES WITH ARCHITECTURAL DRAWINGS.
2. PROVIDE RAPID MOUNT T -BAR FRAME FOR PLASTER AND SHEET ROCK CEILINGS.
3. SUPPLY COMPLETE WITH FACTORY INSTALLED 1/2" THICK FOIL BACKED INSULATION.
4. FACE SIZE DEPENDENT UPON NECK SIZE.
5. PROVIDE STEEL GRILLE WHEN USED IN ACCORDANCE WITH U.L. APPROVED PENETRATION DETAIL,
2. ION GENERATORS
BETWEEN SUPPORT POINTS
IN AN
E1-2, G1-4,
..A -CFM
CFM
CFM
RANGE
I NECK SIZE
DRIVE TYPE E.S.P.
WATTS/HP R.P.M. I VOLTS/PH SONES
0-40
SP
0-95
41
- 60
6"0
96
- 205
600
8Is0
206
- 375
146
10"o
376
- 605
172 WATTS 1100 1 120/10 5.0
12"0
606
- 850
200
14"0
E1-2, G1-4,
B -CFM
CFM
RANGE
I NECK SIZE
NECK SIZE
DRIVE TYPE E.S.P.
WATTS/HP R.P.M. I VOLTS/PH SONES
0-40
SP
4"O
41
- 60
5"0
61
- 95
600
96
- 145
740
146
- 205
8"0
E1-2, G1-4,
H -CFM
CFM
RANGE
MARK AREA SERVED TYPE J
NECK SIZE
DRIVE TYPE E.S.P.
WATTS/HP R.P.M. I VOLTS/PH SONES
MANUFACTURER I MODEL N0. 1NOTFq
SP
0
- 75
WHERE SPECIFIED
6"x6"
76
- 150
ACCESS DOOR
/
10"x6"
151
- 200
EF -1 BATHROOM CABINET
12"6"
201
-250
172 WATTS 1100 1 120/10 5.0
12"x8"
251
- 300
200
14"x8"
SEE NOTE 3
THREADED
HANGER ROD -
1 UNISTRUT OF
A 1 ,� I ANGLE IRON
STRAP HANGERS
SCREWS TYPICAL
CONTINUOUS HANGER STRAP
1" MIN -°- -*-- AROUND DUCT
NOTES:
1. ON DUCTS OVER 48" WIDE, BOTTOM
SHALL BE BRACED BY ANGLE. FOR
CROSS SECTION AREA MORE THAN 8
SQ FT, DUCT SHALL BE BRACED BY
ANGLES ON ALL FOUR SIDES.
2. CUTTING AND PATCHING SHALL BE
LIMITED TO A MINIMUM AS REQUIRED
FOR PROPER INSTALLATION.
3, REFER TO SMACNA FOR SPECIFIC
RECOMMENDED HANGER TYPES NOTED.
BAND
4. MAXIMUM SPACING BETWEEN HANGER
LOCATIONS SHALL BE 8'-0" PER PAIR.
STRAPS SHALL BE MINIMUM 1 1/2" x
22 GAGE GALVANIZED STEEL.
STRAP OR
TRAPEZE HANGERS
F
BAND
STRAPS
HANGER BAND
SCALE: NTS
36" DIA. MAX.
36" DIA. MAX.
FOR STRUCTURAL CONCRETE FLOOR
SLABS OR ROOF DECK:. SUSPEND
WITH PROPERLY SIZED ' CONCRETE
INSERTS OR EXPANSION ANCHORS --�
DO NOT INSTALL INSERTS
OR ANCHORS IN THIN
PORTIONS OF CONCRETE
SUF
FAC
©w
LET DUCT
DESIGN OU'TSi�E
iAiiiC NOMINAL TANNAGE TOTAL COOLIi'JG TarAL IiEA1'ING (EITU) �. g NOTES
,�,.�-. _ . _ _ CrIt;J�- AIR Cr
R45-1 1D.0 120 lvs i i 4 r&fIII 575 1-3
NOTES:
1. CONTRACTOR SHALL REBALANCE THE EXISTING AIR HANDLING UNIT TO THE SPECIFIED
DESIGN CFM INDICATED ON SCHEDULE, ADJUST MOTOR TO A LOWER SPEED IF DIRECT DRIVE
OR ADJUST SHEEVES AND PULLEYS TO MAINTAIN DESIRED QUANTITY OF SPECIFIED SUPPLY
AIR. TEST AND BALANCE CONTRACTOR SHALL SUBMIT RECORDINGS ON CERTIFIED NEBB OR
AABC FORMS.
2. CONTRACTOR TO SET OUTSIDE AIR INTAKE DAMPER FOR DESIRED CFM INDICATED ON
SCHEDULE.
3. CONTRACTOR TO VERIFY SMOKE DETECTOR WITHIN SUPPLY AND RETURN DUCTWORK AND
PROVIDE IF NECESSARY.
UNIT
EXHAUST FAN SCHEDULE
SERVICE
MARK AREA SERVED TYPE J
CFM
DRIVE TYPE E.S.P.
WATTS/HP R.P.M. I VOLTS/PH SONES
MANUFACTURER I MODEL N0. 1NOTFq
SP
MAXIMUM
VELOCITY
DAMPER
WHERE SPECIFIED
ROUND SPIN -IN COLLAR MOUNT CAULK (TYPICAL)
IN SIDE OF DUCT UNLESS
VARIABLE
N0.
ACCESS DOOR
/
TREATED
SPECIFICALLY SHOWN OTHERWISE DUCT SEALER AT SPIN
ELECTRODE
EF -1 BATHROOM CABINET
DRY
150
DIRECT 0.4
172 WATTS 1100 1 120/10 5.0
GREENHECK SP -13200 1
EF -2 BREWING INLINE
QTY
200
DIRECT 0.4
62 WATTS 1000 1 120/10 3.4
GREENHECK CSP -A250 2
.NNOIE2
1. PROVIDE COMPLETE WITH FUSED DISCONNECT SWITCH, DESIGNER GRILLE,
FACTORY HANGING VIBRATION ISOLATOR KIT. SWITCH WITH ROOM LIGHT.
2. PROVIDE COMPLETE WITH FUSED DISCONNECT SWITCH, DESIGNER GRILLE,
FACTORY HANGING VIBRATION ISOLATOR KIT.
FACTORY SOLID STATE SPEED CONTROLLER,
FACTORY SOLID STATE SPEED CONTROLLER,
FACTORY BACKDRAFT DAMPER, AND
FACTORY BACKDRAFT DAMPER, AND
SEE NOTE 3
THREADED
HANGER ROD -
1 UNISTRUT OF
A 1 ,� I ANGLE IRON
STRAP HANGERS
SCREWS TYPICAL
CONTINUOUS HANGER STRAP
1" MIN -°- -*-- AROUND DUCT
NOTES:
1. ON DUCTS OVER 48" WIDE, BOTTOM
SHALL BE BRACED BY ANGLE. FOR
CROSS SECTION AREA MORE THAN 8
SQ FT, DUCT SHALL BE BRACED BY
ANGLES ON ALL FOUR SIDES.
2. CUTTING AND PATCHING SHALL BE
LIMITED TO A MINIMUM AS REQUIRED
FOR PROPER INSTALLATION.
3, REFER TO SMACNA FOR SPECIFIC
RECOMMENDED HANGER TYPES NOTED.
BAND
4. MAXIMUM SPACING BETWEEN HANGER
LOCATIONS SHALL BE 8'-0" PER PAIR.
STRAPS SHALL BE MINIMUM 1 1/2" x
22 GAGE GALVANIZED STEEL.
STRAP OR
TRAPEZE HANGERS
F
BAND
STRAPS
HANGER BAND
SCALE: NTS
36" DIA. MAX.
36" DIA. MAX.
FOR STRUCTURAL CONCRETE FLOOR
SLABS OR ROOF DECK:. SUSPEND
WITH PROPERLY SIZED ' CONCRETE
INSERTS OR EXPANSION ANCHORS --�
DO NOT INSTALL INSERTS
OR ANCHORS IN THIN
PORTIONS OF CONCRETE
SUF
FAC
©w
LET DUCT
DESIGN OU'TSi�E
iAiiiC NOMINAL TANNAGE TOTAL COOLIi'JG TarAL IiEA1'ING (EITU) �. g NOTES
,�,.�-. _ . _ _ CrIt;J�- AIR Cr
R45-1 1D.0 120 lvs i i 4 r&fIII 575 1-3
NOTES:
1. CONTRACTOR SHALL REBALANCE THE EXISTING AIR HANDLING UNIT TO THE SPECIFIED
DESIGN CFM INDICATED ON SCHEDULE, ADJUST MOTOR TO A LOWER SPEED IF DIRECT DRIVE
OR ADJUST SHEEVES AND PULLEYS TO MAINTAIN DESIRED QUANTITY OF SPECIFIED SUPPLY
AIR. TEST AND BALANCE CONTRACTOR SHALL SUBMIT RECORDINGS ON CERTIFIED NEBB OR
AABC FORMS.
2. CONTRACTOR TO SET OUTSIDE AIR INTAKE DAMPER FOR DESIRED CFM INDICATED ON
SCHEDULE.
3. CONTRACTOR TO VERIFY SMOKE DETECTOR WITHIN SUPPLY AND RETURN DUCTWORK AND
PROVIDE IF NECESSARY.
UNIT
PROVIDE ANGLES
SERVICE
ION
GENERATORS
AT TOP AND SIDES
MARK
MAX
SP
MAXIMUM
VELOCITY
DAMPER
WHERE SPECIFIED
ROUND SPIN -IN COLLAR MOUNT CAULK (TYPICAL)
IN SIDE OF DUCT UNLESS
VARIABLE
N0.
ACCESS DOOR
/
TREATED
SPECIFICALLY SHOWN OTHERWISE DUCT SEALER AT SPIN
ELECTRODE
(CFM)
DRY
POWER
OUTPUT W/
MANUFACTURER & MODEL
COLLAR CONNECTION
AIRFLOW
QTY
PAIRS
RV -1
CONTACTS
(VA)
AIRFLOW
NUMBER
F-1
ADJUSTABLE CLAMP TO MAIN
2
2
700
INCLUDED
0.8 VA
INTEGRAL
PLASMA AIR - N7200
NOTES:
1.140
UPPER ATTACHMENT PER SMACNA SUPPLY DUCT SIZE AS
MAX. SAG 1/2" PER FOOT SHOWN ON PLANS
117
197.0
0.06
0.0
1. INSTALL ION GENERATOR
IN
LOCATION
SHOWN
ON PLANS.
33
2. ION GENERATORS
BETWEEN SUPPORT POINTS
IN AN
ACCESSIBLE LOCATION.
0.80
3. ION GENERATORS SHALL BE POWERED
WITH 24 V FAN CONTROL.
#6 Mens1
115
92.0
0.00
0.0
0.00
0.80
0 0
1.314
0
3221
1011
0.877
LOUVER
MAXIMUM D/8 OFFSET
\ i
ALLOWED IN LAST D INCHES
\i
TO DEVICE WHERE D IS THE
L
INTERNAL FLEX DIAMETER SEE NOTE 3
ADJUSTABLE CLAMP STAINLESS STEEL VOLUME DAMPER WITH LOCKING
SECURE TO
CAM LOCK LATCH
CURB WITH
QUADRANT AND 2 STANDOFF
NECK SIZE TO MATCH DUCT SEALER
SS #8x1"
FASTENERS (TYPICAL)
FLEX DUCT SIZE INDICATED INSULATE TOP PANEL
OF LAY -IN DIFFUSER
PROVIDE INSULATED METAL
WOOD NAILER -�
PANEL ON UNUSED PORTION
MINIMUM 12" TALL
OF LOUVER. CAULK EDGES
INSULATED ROOF CURB
AIR TIGHT.
CEILING (T -BAR SHOWN) AIR DISTRIBUTION DEVICE, SEE PROVIDE CEILING ACCESS
CANT
GYPSUM BOARD SIMILAR SCHEDULE. LAY -IN SHOWN PANEL FOR DAMPER ACCESS
SURFACE MOUNT SIMILAR IN NON -ACCESSIBLE CEILINGS
�+
DUCT
,+,t�°,�e
CONNECTION 1 O LOUVER
NOTES,
SCALE: NONE
1. FLEXIBLE DUCTS SHALL BE ONE-PIECE AND SHALL NOT BE SPLICED TOGETHER.
2. EXTEND FLEXIBLE DUCT INSULATION TO DUCT/DIFFUSER PANEL INSULATION AND SEAL WITH MASTIC.
3. MINIMUM 1-1/2" WIDE 22 GAUGE GALVANIZED STRAP HANGER. INSTALL PER GUIDELINES SET FORTH IN CHAPTER 3 OF THE MOST
MEMBRANE
CURRENT EDITION OF THE S.M.A.C.N.A. TECHNICAL MANUAL TITLED "HVAC DUCT CONSTRUCTION STANDARDS METAL AN FLEXIBLE".
ROOFING
4. FLEXIBLE AIR DUCT SHALL BE FULLY EXTENDED AND NOT COMPRESSED. ELBOW RADIUS SHALL BE NO LESS THAN R/D=1.0.
LIGHT
WEIGHT
FLEXIBLE DUCT INSTALLATION DETAIL
DECK
SCALE: NTS
SEE NOTE 3
THREADED
HANGER ROD -
1 UNISTRUT OF
A 1 ,� I ANGLE IRON
STRAP HANGERS
SCREWS TYPICAL
CONTINUOUS HANGER STRAP
1" MIN -°- -*-- AROUND DUCT
NOTES:
1. ON DUCTS OVER 48" WIDE, BOTTOM
SHALL BE BRACED BY ANGLE. FOR
CROSS SECTION AREA MORE THAN 8
SQ FT, DUCT SHALL BE BRACED BY
ANGLES ON ALL FOUR SIDES.
2. CUTTING AND PATCHING SHALL BE
LIMITED TO A MINIMUM AS REQUIRED
FOR PROPER INSTALLATION.
3, REFER TO SMACNA FOR SPECIFIC
RECOMMENDED HANGER TYPES NOTED.
BAND
4. MAXIMUM SPACING BETWEEN HANGER
LOCATIONS SHALL BE 8'-0" PER PAIR.
STRAPS SHALL BE MINIMUM 1 1/2" x
22 GAGE GALVANIZED STEEL.
STRAP OR
TRAPEZE HANGERS
F
BAND
STRAPS
HANGER BAND
SCALE: NTS
36" DIA. MAX.
36" DIA. MAX.
FOR STRUCTURAL CONCRETE FLOOR
SLABS OR ROOF DECK:. SUSPEND
WITH PROPERLY SIZED ' CONCRETE
INSERTS OR EXPANSION ANCHORS --�
DO NOT INSTALL INSERTS
OR ANCHORS IN THIN
PORTIONS OF CONCRETE
SUF
FAC
©w
LET DUCT
DESIGN OU'TSi�E
iAiiiC NOMINAL TANNAGE TOTAL COOLIi'JG TarAL IiEA1'ING (EITU) �. g NOTES
,�,.�-. _ . _ _ CrIt;J�- AIR Cr
R45-1 1D.0 120 lvs i i 4 r&fIII 575 1-3
NOTES:
1. CONTRACTOR SHALL REBALANCE THE EXISTING AIR HANDLING UNIT TO THE SPECIFIED
DESIGN CFM INDICATED ON SCHEDULE, ADJUST MOTOR TO A LOWER SPEED IF DIRECT DRIVE
OR ADJUST SHEEVES AND PULLEYS TO MAINTAIN DESIRED QUANTITY OF SPECIFIED SUPPLY
AIR. TEST AND BALANCE CONTRACTOR SHALL SUBMIT RECORDINGS ON CERTIFIED NEBB OR
AABC FORMS.
2. CONTRACTOR TO SET OUTSIDE AIR INTAKE DAMPER FOR DESIRED CFM INDICATED ON
SCHEDULE.
3. CONTRACTOR TO VERIFY SMOKE DETECTOR WITHIN SUPPLY AND RETURN DUCTWORK AND
PROVIDE IF NECESSARY.
RELIEF VENT SCHEDULE
UNIT
MANUFACTURER & MODEL NO.
SERVICE
ION
GENERATORS
CAPACITY
MARK
MAX
SP
MAXIMUM
VELOCITY
DAMPER
CURB
OPER. WT.
VARIABLE
N0.
TREATED
t1 Bar 1
ELECTRODE
(CFM)
DRY
POWER
OUTPUT W/
MANUFACTURER & MODEL
TYPE
AIRFLOW
QTY
PAIRS
RV -1
CONTACTS
(VA)
AIRFLOW
NUMBER
F-1
1800
2
2
700
INCLUDED
0.8 VA
INTEGRAL
PLASMA AIR - N7200
NOTES:
1.140
#4 Corridor 1
117
197.0
0.06
0.0
1. INSTALL ION GENERATOR
IN
LOCATION
SHOWN
ON PLANS.
33
2. ION GENERATORS
SHALL BE INSTALLED
IN AN
ACCESSIBLE LOCATION.
0.80
3. ION GENERATORS SHALL BE POWERED
WITH 24 V FAN CONTROL.
#6 Mens1
RELIEF VENT SCHEDULE
UNIT
MANUFACTURER & MODEL NO.
SERVICE
LOCATION
TYPE
CAPACITY
HOOD HEIGHT
(W/O CURB)
THROAT
AREA
SP
MAXIMUM
VELOCITY
DAMPER
CURB
OPER. WT.
REMARKS
N0.
t1 Bar 1
RELIEF/INTAKE
(CFM)
(IN)
(FT)
(IN WG)
(FPM)
TYPE
TYPE/HEIGHT
(LBS)
468
RV -1
GREENHECK CRSR-20
BREW -KETTLE
ROOF
RELIEF
1575
13.0
2.25
0.05
700
BACKDRAFT
STANDARD
24
1
NOTES: 1. ALUMINUM HOUSING, GALVANIZED BIRDSCREEN, BAKED ENAMEL. COLOR TO BE SELECTED BY ARCHITECT.
i-- ALUMINUM TOP CAP
ROOF CURB
RIGID INSULATION
3/8" ALL THREAD
SPUN ALUMINUM VENTURI INLET
,,-BACKDRAFT DAMPER
COUNTER FLASHING
FLASHING
7` /--`ROOF MEMBR4
EQUIPMENT
RUBBER INSULATION
FULL CONTOUR OF CURB
FLASHING
-CONTINUOUS CANT
MEMBRANE ROOFING
�- LIGHT WEIGHT DECK
\- RIGID INSULATION
RELIEF VENT INSTALLATION DETAIL
SCALE: NTS
FOR METAL ROOF DECKS:
SUSPEND FROM STRUCTURAL
STEEL OR PROVIDE MISCELLANEOUS
STEEL TO SPAN BETWEEN STRUCTURAL
STEEL ELEMENTS.
THREADED BEAM CLAMP
HANGING ROD
/-FLEXIBLE CONNECTOR WITH
GROUND STRAP (TYP.)
CEILING
EXHAUST GRILLE
_OPRENE GROMMET AND SHAFT
FEVE SECURED WITH STEEL
4SHERS & NUTS ON BOTH
DES OF EACH MOUNTING
BRACKET (TYPICAL -4)
DO NOT SUPPORT FAN
FROM CEILING
CEILING MOUNTED EXHAUST FAN DETAIL
SCALE: NTS
Ventilation Sizing Summary for Existing RTU -"1
Project Name: 117094.00 Deviant Wolfe Brewery 05/1612017
Prepared by: Ingenuity Engineers Inc. 10:04AM
`1. Summary
Supply Air
.(CFM)
Ventilation Sizing Method......_................................................
ASHRAE Std 62.1-2007
Design Condition _.... _.---------------- .............._........_......-_:.............._..
Heating operation
OccupantDiversity .............. __........ ................ .......................
........ ........ ................... 1.000
Uncorrected Ventilation Airflow Rate .... ..............._.............
-___......__........_......._........_....1011 CFM
System Ventilation Efficiency
......................... 0.877
Design Ventilation Airflow Rate ........................................................
1152 CFM
2. Snace Ventilation AnalvGig Tnhla
Zone Name! Space Name Mull.
Supply Air
.(CFM)
Floor
Area
(ft-)
Required
Outdoor Air
(CFMKO)
Time
Averaged
Occupancy
Required
Outdoor Air
(CFM/person)
Air
Distribution
Effectiveness
Required Uncorrected
Outdoor Air Outdoor Air
(CFM) (CFM)
Space
Ventilation
Efficiency
Zone 1
t1 Bar 1
2405
1497.0
0.18
76.0
7.50
0.80
•1049 839
0.877
42 Brewery 1
468
655.0
0.18
4.0
7.50
0.80
•185 148
0.9119
#3 Office 1
82
108.0
0.06
1.0
5.00
0.80
14 11
1.140
#4 Corridor 1
117
197.0
0.06
0.0
0.00
0.80
_
'15 12
1.188
#5 Womens 1
33
105.0
0.00
0.0
0.00
0.80
0 0
1.314
#6 Mens1
115
92.0
0.00
0.0
0.00
0.80
0 0
1.314
Totals (incl, Space Multipliers)
3221
1011
0.877
SIDE TAKE -OFF FITTING - EQUAL
TO FLEXMASTER STO (22 GA. MIN.)
MAX. 15' TRANSITION 0.25 D
RECTANGULAR DUCT/ -ROUND DUCT
i
TO AIR
Q Q
N J VALVE
o_
o_
VOLUME DAMPER N
CONICAL FITTING WITH LOCKING TYPE VOLUME DAMPER.
DAMPER AND DAMPER STAND-OFF EQUAL TO CROWN
PRODUCTS COMPANY MODEL 3200 -DS,
1
FLEX DUCT OR ROUND SHEET METAL DUCT. FLEX
o DUCT MAX. 8'-0" LONG, USE CLAMP TO ATTACH
U FLEX DUCTS AND SEAL AS PER SPECIFICATIONS,
SUPPORT FLEX DUCT EVERY 3'-0" FROM STRUCTURE.
J
a
a
DUCT CONNECTION DETAILS
SCALE: NTS
CAIk 26308 I�i_7094.00
4798 NEW BROAD STREET
SUITE 300
ORLANDO, FL 32814
407.398.6007 (P)
i
407.398.6003 (F)
A& Him
9t '� "�rosctreE,yxcYrm�Sc'�.ars"
11 u
;?
encyineer , inc.
0 `o
. ! CN
_o
x `!
_.,i
41 V) U'
L
.0
r0 LIJ
v / 0
0 0
CLSC0
C14
u
Lu c' 'urte)
L'' �• i d �.. E N ;Q M '
td i e =r e O u_ CO
co
N l0
N, a�a�,,r, �siik (j Qo.
3 a
c : N P`i•, Y R.i ..ar, JSP '�, V L00 'r
Q �...
d) ¢o
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN! ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
ed
:(FIJI
`' syr r�Q
W
UO3 0
�r1�ti
n
v�
ZU
N
a.
SHEET INFORMATION
DATE: 06/26/2017
DRAWN BY: DMA
PROJECT NO: 16-2235
RENEWED BY: JBH
wl Plan Revisions Date:
ELECTRICAL SPEC-FICATIONS--
mummmmm
GENERAL
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE
FLORIDA BUILDING CODE (FBC), NFPA 101, ALL LOCAL CODES, ORDINANCES,
REGULATIONS AND UTILITY POWER AND TELEPHONE COMPANY STANDARDS.
2. ALL BUILDING WIRE SHALL BE COPPER TYPE "THHN/THWN" FOR ALL SIZES.
MINIMUM WIRE SIZE SHALL BE #12 AWG.
3. ALL BRANCH AND FEEDER CIRCUITS SHALL CONTAIN A SEPARATE GROUNDING
CONDUCTOR AND SEPARATE NEUTRAL CONDUCTOR AND SHALL BE SIZED AND
BONDED IN ACCORDANCE WITH ARTICLE 250 OF THE N.E.C.
4. ALL CONDUIT INSTALLED IN INTERIOR LOCATIONS SHALL BE TYPE E.M.T. WITH SET
SCREW STEEL CONNECTORS AND COUPLINGS. ALL EMT SHALL BE A MINIMUM 1/2".
ALL CONDUIT INSTALLED IN EXTERIOR LOCATIONS, ABOVE GRADE, SHALL BE
GALVANIZED RIGID CONDUIT. ALL CONDUIT BELOW GRADE SHALL BE SCHEDULE 40
P.V,C. ALL CONDUIT SHALL BE INSTALLED CONCEALED. THE USE OF METAL CLAD
CABLE (MC) SHALL BE PERMITTED ON THIS PROJECT.
5. CONTRACTOR SHALL COORDINATE THE LOCATION OF RECEPTACLES, CONTROL
CIRCUITS, COMMUNICATIONS AND DATA OUTLETS, LIGHTING FIXTURES AND DEVICES
WITH THE OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION.
6. DRAWINGS ARE DIAGRAMMATIC - CONTRACTOR SHALL REFER TO ARCHITECTURAL
DRAWINGS AND FIELD CONDITIONS FOR ALL DIMENSIONS.
7. CONTRACTOR SHALL OBTAIN AND FURNISH ALL PERMITS REQUIRED. PROVIDE ALL
LABOR, MATERIALS, EQUIPMENT, APPLIANCES AND TOOLS TO PERFORM ALL WORK
NECESSARY FOR THE COMPLETE EXECUTION OF THE ELECTRICAL WORK AS SHOWN
ON THE DRAWINGS. PROVIDE WORK NOT SPECIFICALLY SHOWN OR SPECIFIED, YET
REQUIRED TO INSURE PROPER AND COMPLETE OPERATION OF ALL SYSTEMS AND
TO SATISFY THE DESIGN INTENT OF THE WORK AND COMPLY WITH ALL APPLICABLE
CODES AND REGULATIONS.
8. THE DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF CIRCUITS, OUTLETS,
LOCATIONS OF SWITCHES, PANELBOARDS, CONDUITS AND OTHER WORK. PRIOR
FIELD VERIFICATION OF ALL DIMENSIONS IS REQUIRED AS PART OF THIS WORK.
CONDUIT RUNS AND GROUNDING ARE SHOWN DIAGRAMMATICALLY ONLY. FIELD
VERIFY THE ACTUAL ROUTING OF CONDUITS PRIOR TO BIDDING.
9. PROVIDE ALL 125VAC 20 AMP SPECIFICATION GRADE RATED WIRING DEVICES
UNLESS OTHERWISE NOTED. PROVIDE MATCHING COVER PLATES, JUNCTION BOXES
AND PLASTER RINGS AS REQUIRED TO FACILITATE THE INSTALLATION OF FLUSH
MOUNTED WIRING DEVICES AS NOTED AND AS THE PROJECT CONDITIONS WARRANT.
■
10. ANY PENETRATIONS MADE THROUGH A FIRE RATED ASSEMBLY SHALL BE PROPERLY
SEALED TO MAINTAIN THE INTEGRITY OF THE ASSEMBLY PER U.L. AND NEPA.
11. CONTRACTOR SHALL PROVIDE STRICT COORDINATION WITH NEW EQUIPMENT AND FIELD
VERIFY THE EXACT FINAL LOCATION AND EQUIPMENT POWER CHARACTERISTICS WITH THE
OWNER'S AUTHORIZED REPRESENTATIVE AND OTHER TRADES PRIOR TO CONSTRUCTION.
12. EACH BIDDER SHALL INSPECT THE SITE AS REQUIRED FOR KNOWLEDGE OF EXISTING
CONDITIONS PRIOR TO BIDDING AND FAILURE TO OBTAIN SUCH KNOWLEDGE SHALL NOT
RELIEVE THE SUCCESSFUL BIDDER OF THE RESPONSIBILITY TO COORDINATE EXISTING
CONDITIONS IN PERFORMING THE WORK UNDER THIS CONTRACT.
13. WHERE NEW WORK CANNOT BE INSTALLED WITHOUT CHANGES IN EXISTING FACILITIES
OR SYSTEMS OR WHERE IT IS INDICATED ON DRAWINGS TO REWORK AN EXISTING
INSTALLATION, THIS CONTRACT SHALL INCLUDE ALTERATIONS TO EXISTING WORK AS
REQUIRED TO INSTALL NEW WORK. ADDITIONS TO THE CONTRACT COST WILL NOT BE
ALLOWED DUE TO THE CONTRACTORS FAILURE TO INSPECT EXISTING CONDITIONS AT
THE SITE OF THE WORK.
14. PROVIDE HACR RATED CIRCUIT BREAKERS FOR ALL HVAC. EQUIPMENT.
15. THE WORK SHALL INCLUDE REVISIONS, MODIFICATIONS, AND REWORK OF THE EXISTING
FACILITY ELECTRICAL SYSTEMS AS REQUIRED FOR INSTALLATION OF NEW WORK, AND
FOR CONNECTIONS BETWEEN EXISTING WORK AND NEW WORK WHERE REQUIRED. THE
WORK SHALL ALSO INCLUDE THE COMPLETION OF ELECTRICAL POWER AND CONTROL
CIRCUITS FOR DEVICES AND EQUIPMENT THAT ARE TO REMAIN IN SERVICE. IF THE
CIRCUITS ARE BROKEN BY DEMOLITION WORK, OR BY THE REMOVAL OR CUTTING OF
EXISTING BUILDING CONSTRUCTION, THE EXISTING CONDUIT AND WIRING SHALL BE
REROUTED AND RECONNECTED WHERE NECESSARY.
16. PROVIDE PANELBOARD MATCHING CIRCUIT BREAKERS IN ORDER TO CONNECT NEW
BRANCH CIRCUITS. UPDATE ALL PANELBOARD DIRECTORIES TO REFLECT THE ACTUAL
CONDITIONS. ALL UPDATES SHALL BE TYPEWRITTEN. ALL NEW ELECTRICAL DEVICES MUST
BE LABELED AT THE DEVICE WITH CIRCUIT AND PANELBOARD NUMBER.
CUTTING AND PATCHING
1. THE RESPONSIBILITY FOR ANY CUTTING OF CONSTRUCTION WHICH IS REQUIRED FOR
THE INSTALLATION OF DIVISION 16 WORK, SHALL BE BY THE CONTRACTOR. THE
CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES AND THE OWNER BEFORE
ANY CUTTING AND OBTAIN APPROVAL FROM THE ARCHITECT/ENGINEER PRIOR TO ANY
CUTTING. ALL PATCHING, PAINTING AND FINISH SHALL BE BY THE CONTRACTOR.
POWER
LIGHTING IN (SEE LIGHTING FIXTURE SCHEDULE)
20R
DUPLEX RECEPTACLE. MOUNTED 18" AFF TO CENTERLINE
STRENGTH OF THE STRUCTURE WILL NOT BE ENDANGERED. WHEREVER POSSIBLE,
2' X 4' FLUORESCENT LIGHT FIXTURE. NUMBER INDICATES
OPENINGS IN CONCRETE OR MASONRY CONSTRUCTION SHALL BE BY CONCRETE
UNLESS OTHERWISE NOTED. WP=WEATHERPROOF. NUMBER
SAW OR ROTARY CORE DRILL. OPENINGS IN ANY CONSTRUCTION SHALL BE CUT
BRANCH CIRCUIT WHICH FIXTURE IS CONNECTED. LOWER
ETR
INDICATES BRANCH CIRCUIT. SEE PANEL BOARD SCHEDULE.
PROTECTION SHALL BE PROVIDED TO PREVENT DAMAGE TO ADJACENT AREAS AND
CASE LETTER INDICATES SWITCH WHICH CONTROLS FIXTURE.
TO PREVENT DUST FROM SPREADING TO ADJACENT AREAS.
ETR = EXISTING TO REMAIN. TP = TAMPER PROOF
AC -
UPPER CASE LETTER INDICATES FIXTURE TYPE. SEE
3. WHERE OPENINGS OR HOLES ARE CUT IN CONSTRUCTION AND THE CUTTING
MILLS
BREAKS ELECTRICAL CIRCUITRY OR CONTROL CIRCUITRY CONDUIT AND WIRING,
LIGHTING FIXTURE SCHEDULE. (NL = NIGHT LIGHT).
jp
DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER HEIGHT OR
CIRCUITRY CONDUIT AND REWIRING AND TO COMPLETE THE CIRCUITRY AS REQUIRED
1. THE CONTRACTOR SHALL KEEP THE CONSTRUCTION SITE CLEAN OF ALL WASTE
AND AS APPROVED BY THE ARCHITECT/ENGINEER. TEMPORARY COMPLETION SHALL
0 HEIGHT INDICATED. +44" AFF TO CENTER.
BE PROVIDED WHERE NECESSARY BEFORE THE PERMANENT REROUTING AND
2' X 4' FLUORESCENT LIGHT FIXTURE WITH 1400 LUMEN
COMPLETION WORK IS FINISHED.
REQUESTED BY THE ARCHITECT/ ENGINEER, THE CONTRACTOR SHALL REMOVE ALL
AWG -
EMERGENCY BATTERY BALLAST. NUMBER INDICATES
fp
GFI RECEPTACLE. MOUNTED 18" AFF TO CENTERLINE
MOISTURE PROTECTION SHALL FIRST BE INSTALLED AS REQUIRED AND AS
BRANCH CIRCUIT WHICH FIXTURE IS CONNECTED. LOWER
SPECIFIED IN THESE SPECIFICATIONS.
UNLESS OTHERWISE NOTED. WP DENOTES WEATHERPROOF
CFL -
CASE LETTER INDICATES SWITCH WHICH CONTROLS FIXTURE.
5. OPENINGS CUT IN FLOOR SHALL BE CUT BY CORE DRILLING WHERE POSSIBLE.
COVER. NO FEED THRU TYPE DEVICES TO BE USED.
AFTER WORK IS INSTALLED THROUGH ANY OPENING IN FLOOR, THE OPENING
UPPER CASE LETTER INDICATES FIXTURE TYPE. SEE
qp
GFI RECEPTACLE MOUNTED ABOVE COUNTER HEIGHT OR 0
SILICONE BASED, NON -CRACKING ELASTOMERIC SEALANT.
LIGHTING FIXTURE SCHEDULE. (NL = NIGHT LIGHT).
MH -
HEIGHT INDICATED. NO FEED THRU DEVICES TO BE USED.
REL
TO BUILDING OCCUPANTS AND THE PUBLIC; TO PREVENT THE SPREADING OF DUST,
+44" AFF TO CENTER.
0
LIGHTING FIXTURE. REL=RELOCATE
v,
TWO DUPLEX RECEPTACLES WITH COMMON COVER MOUNTED
CONTRACTOR SHALL MATCH THE COLOR, TYPE AND THICKNESS OF PAINT AS
CARBON MONOXIDE
PREVIOUS.
18" AFF TO CENTERLINE UNLESS OTHERWISE NOTED. TO BE
®}
BY HIMSELF OR HIS EMPLOYEES. HE SHALL ALSO BE RESPONSIBLE FOR ALL
EXIT SIGN - SINGLE FACE ARROW INDICATES DIRECTION -
CUTTING AND PATCHING REQUIRED TO PROPERLY INSTALL HIS WORK. THIS SHALL
CH
ALSO INCLUDE THE PATCHING OF EXISTING ROADWAYS (PAVED OR IMPROVED),
1. UPON COMPLETION OF WORK, THE ENTIRE WIRING SYSTEM SHALL BE TESTED, AND
CEILING MOUNTED WITH INTEGRAL 90 MINUTE EMERGENCY
SHALL BE SHOWN TO BE IN PROPER WORKING CONDITION IN ACCORDANCE WITH
TWO DUPLEX GFI RECEPTACLES WITH COMMON COVER MOUNTED
INTENT OF SPECIFICATIONS AND DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF
BATTERY POWER SUPPLY.
THE CONTRACTOR TO HAVE ALL SYSTEMS READY FOR OPERATION AND TO HAVE AN THE
18" AFF TO CENTERLINE UNLESS OTHERWISE NOTED.
ELECTRICIAN AVAILABLE TO OPERATE SAME IN ACCORDANCE WITH AND UNDER THE
FIXTURE PROVIDED OWNER
1p
TWO DUPLEX GFI RECEPTACLES WITH COMMON COVER MOUNTED
THE CONTRACTOR SHALL BE AVAILABLE TO ASSIST IN REMOVAL OF PANEL FRONTS,
lei
EXIT SIGN - DOUBLE FACE - ARROW INDICATES DIRECTION
DOWNLIGHT
ABOVE COUNTER OR AT HEIGHT INDICATED. +44i' AFF TO
DEMO -
DEMOLITION
NFPA -
- CEILING MOUNTED WITH INTEGRAL 90 MINUTE
CUSTOM CHANDELIER
CENTER.
120
EMERGENCY BATTERY POWER SUPPLY.
S
SINGLE POLE SWITCH - TOGGLE TYPE. SEE ELECTRICAL
NTS
V.
SPECIFICATIONS FOR MOUNTING HEIGHTS.
4�&?
EMERGENCY LIGHT WITH INTEGRAL 90 MINUTE EMERGENCY
ECB -
(3) 3 WAY
120
BATTERY POWER SUPPLY. -
"C"
INSTALLED BY ELECTRICIAN
NIC -
DUAL HEAD. = CEILING MOUNTED
ELEC -
(D) DIMMER
SOS
WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR
NL -
NIGHT LIGHT
EM -
SWITCH LITHONIA LIRW SERIES.
FIRE ALARM
�
CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR
O.C. -
*
LUTRON LOS -CDT SERIES. "*" INDICATES FIXTURES IN
Eh
WALL MOUNTED COMBINATION AUDIBLE/VISUAL SIGNALING
SENSOR'S ZONE OF CONTROL.
SYSTEM
UNIT- HORN/FLASHING "FIRE" LIGHT.
SM
1 -POLE OR 2 -POLE 30AMP MOTOR RATED SWITCH WITH
F]
MANUAL PULL STATION WP=WEATHERPROOF
PANELBOARD
INTEGRAL OVERLOADS.
EXHAUST FAN
PVC -
POLYVINYL CHLORIDE
ETR -
FAC
FIRE ALARM CONTROL PANEL.
UJ
JUNCTION BOX
EXISTING
RGS -
RIGID GALVANIZED STEEL
FA -
142
CEILING MOUNTED SMOKE DETECTOR.
ROOM
MOTOR OPERATED CEILING PADDLE FAN. PROVIDE CONNECTION
BOX FOR WEIGHT OF FAN PLUS ADDITIONAL 200LBS.
FACP
EXISTING FIRE ALARM PANEL.
SPECIFICATION
FBC -
FLORIDA BUILDING CODE
SS -
SERVICE AND I TRI INION
em BRANCH CIRCUIT PANELBOARD, 120/208V, SURFACE
MOUNTED
"y
A -
AS -BUILT DRAWINGS
2. CUTTING SHALL BE DONE WITH EXTREME CARE AND IN SUCH A MANNER THAT THE
1. THE CONTRACTOR SHALT_ PROVIDE AND KEEP UP TO DATE A COMPLETE RECORD
STRENGTH OF THE STRUCTURE WILL NOT BE ENDANGERED. WHEREVER POSSIBLE,
SET OF CONSTRUCTION "AS-BUILTS" BLUELINE PRINTS WHICH SHALL BE
OPENINGS IN CONCRETE OR MASONRY CONSTRUCTION SHALL BE BY CONCRETE
CORRECTED DAILY, AND SHALL SHOW EVERY CHANGE FROM THE ORIGINAL
SAW OR ROTARY CORE DRILL. OPENINGS IN ANY CONSTRUCTION SHALL BE CUT
CONTRACT DRAWINGS, INCLUDING ADDENDA AND CHANGE ORDERS IN ACCORDANCE
THE MINIMUM SIZE REQUIRED FOR THE INSTALLATION OF THE WORK. ADEQUATE
WITH GENERAL REQUIREMENTS AND SPECIAL CONDITIONS. THIS SET OF PRINTS
PROTECTION SHALL BE PROVIDED TO PREVENT DAMAGE TO ADJACENT AREAS AND
SHALL BE KEPT ON THE JOB SITE, AND SHALL BE USED ONLY AS A RECORD SET,
TO PREVENT DUST FROM SPREADING TO ADJACENT AREAS.
THIS SHALL NOT BE CONSTRUED AS AUTHORIZATION FOR THE CONTRACTORS TO
AC -
MAKE CHANGES IN THE LAYOUT WITHOUT DEFINITE INSTRUCTION IN EACH CASE.
3. WHERE OPENINGS OR HOLES ARE CUT IN CONSTRUCTION AND THE CUTTING
MILLS
BREAKS ELECTRICAL CIRCUITRY OR CONTROL CIRCUITRY CONDUIT AND WIRING,
PROTECTION
THEN IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REROUTE THE
KILOVOLT -AMPERES
CIRCUITRY CONDUIT AND REWIRING AND TO COMPLETE THE CIRCUITRY AS REQUIRED
1. THE CONTRACTOR SHALL KEEP THE CONSTRUCTION SITE CLEAN OF ALL WASTE
AND AS APPROVED BY THE ARCHITECT/ENGINEER. TEMPORARY COMPLETION SHALL
MATERIALS AND RUBBISH CAUSED BY HIS WORK OR EMPLOYEES. UPON
BE PROVIDED WHERE NECESSARY BEFORE THE PERMANENT REROUTING AND
COMPLETION OF THE WORK AND AT TIMES DURING PROGRESS OF THE WORK WHEN
COMPLETION WORK IS FINISHED.
REQUESTED BY THE ARCHITECT/ ENGINEER, THE CONTRACTOR SHALL REMOVE ALL
AWG -
SURPLUS MATERIALS, RUBBISH, AND DEBRIS RESULTING FROM THE OPERATION,
4. BEFORE ANY CUTTING, PATCHING, OR FINISHING WORK IS STARTED, DUST AND
AND SHALL LEAVE THE ENTIRE BUILDING AND INVOLVED PORTIONS OF THE SITE,
MOISTURE PROTECTION SHALL FIRST BE INSTALLED AS REQUIRED AND AS
INSOFAR AS THE WORK OF THE CONTRACT IS CONCERNED IN A NEAT CLEAN
SPECIFIED IN THESE SPECIFICATIONS.
AND ACCEPTABLE CONDITION AS APPROVED BY THE ARCHITECT/ENGINEER.
CFL -
EQUIPMENT, LIGHTING FIXTURES, MATERIALS AND ACCESSORIES SHALL BE
5. OPENINGS CUT IN FLOOR SHALL BE CUT BY CORE DRILLING WHERE POSSIBLE.
THOROUGHLY CLEANED OF CEMENT, PLASTER, AND OTHER MATERIALS.
AFTER WORK IS INSTALLED THROUGH ANY OPENING IN FLOOR, THE OPENING
P
D WORK SHALL BE PATCHED AND SEALED WATERTIGHT AND EPDXY OR
AROUND THE
2. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION, WHEREVER WORK IS TO
SILICONE BASED, NON -CRACKING ELASTOMERIC SEALANT.
BE PERFORMED IN FINISHED/OCCUPIED SPACES, TO PREVENT DAMAGE TO
MH -
ADJACENT AREAS, EQUIPMENT, OR FURNISHINGS; TO PREVENT ACCIDENTAL INJURY
PAINTING
TO BUILDING OCCUPANTS AND THE PUBLIC; TO PREVENT THE SPREADING OF DUST,
DIRT, DEBRIS, AND MOISTURE FROM THE AREA WHERE WORK IS BEING PERFORMED;
1. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAINTING AREAS OF CONSTRUCTION
AND TO PREVENT DUST, DIRT, DEBRIS, AND MOISTURE FROM GETTING ON OR IN
THAT ARE SCRATCHED, MARRED, OR DAMAGED BY THE NEW CONSTRUCTION.
THE BUILDING OCCUPANTS FURNISHINGS OR EQUIPMENT.
CONTRACTOR SHALL MATCH THE COLOR, TYPE AND THICKNESS OF PAINT AS
CARBON MONOXIDE
PREVIOUS.
3. THE CONTRACTOR SHALL REPAIR, AT NO COST TO THE OWNER, ANY DAMAGE DONE
Lij
BY HIMSELF OR HIS EMPLOYEES. HE SHALL ALSO BE RESPONSIBLE FOR ALL
ACCEPTANCE TESTING
CUTTING AND PATCHING REQUIRED TO PROPERLY INSTALL HIS WORK. THIS SHALL
CONC -
ALSO INCLUDE THE PATCHING OF EXISTING ROADWAYS (PAVED OR IMPROVED),
1. UPON COMPLETION OF WORK, THE ENTIRE WIRING SYSTEM SHALL BE TESTED, AND
PARKING AREAS, SIDEWALKS, CURBS, GUTTERS, ETC., CUT TO INSTALL WORK
SHALL BE SHOWN TO BE IN PROPER WORKING CONDITION IN ACCORDANCE WITH
PROVIDED BY THE CONTRACTOR. PATCH WORK SHALL COMPLY WITH THE
INTENT OF SPECIFICATIONS AND DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF
SECTIONS OF THESE SPECIFICATIONS AND SHALL MATCH THE EXISTING
THE CONTRACTOR TO HAVE ALL SYSTEMS READY FOR OPERATION AND TO HAVE AN THE
FINISHES.
ELECTRICIAN AVAILABLE TO OPERATE SAME IN ACCORDANCE WITH AND UNDER THE
FIXTURE PROVIDED OWNER
SUPERVISION OF THE INSPECTION REPRESENTATIVE OF THE ARCHITECT/ENGINEER.
1 0O
THE CONTRACTOR SHALL BE AVAILABLE TO ASSIST IN REMOVAL OF PANEL FRONTS,
NATIONAL ELECTRICAL
ETC., TO PERMIT INSPECTION AS REQUIRED.
COPPER
A -
AMPERES
KAIC -
[THOUSAND). AMPERE
120
AS APPROVED BY OWNER
I TERRUPTINNG CAPACITY
A/C -
AIR CONDITIONING
_
v)
y*
w 4-J uj
FIXTURE PROVIDED OWNER
KCMIL -
THOUSANDS OF CIRCULAR
AC -
ALTERNATING CURRENT
rummumm
MILLS
AFF -
ABOVE FINISHED FLOOR
KVA -
KILOVOLT -AMPERES
AFG -
ABOVE FINISHED GRADE
KW -
KILOWATT
AHU -
AIR HANDLING UNIT
LED -
LIGHT EMITTING DIODE
AWG -
AMERICAN WIRE GAUGE
LTG -
LIGHTING
C -
CONDUIT
MCP -
MOTOR CIRCUIT PROTECTION
CFL -
COMPACT FLUORESCENT
MCU -
MASTER CONTROL UNIT
COPYING, OR USE OF THIS DOCUMENT
P
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
EMERGI-LITE
MH -
METAL HALIDE
CH -
COUNTER HEIGHT
ELXN400G-2LED
SIGN WITH INTEGRAL 90 MINUTE
LEDD
N -
NEUTRAL
CM -
CARBON MONOXIDE
EMERGENCY BATTERY PACK
0
Lij
NA -
NOT APPLICABLE
CONC -
CONCRETE
120
AS APPROVED BY OWNER
EL-2LEDW
NEC -
NATIONAL ELECTRICAL CODE
COND -
CONDUIT
F
FIXTURE PROVIDED OWNER
DIMMABLE SURFACE MOUNTED
1 0O
NEMA -
NATIONAL ELECTRICAL
CU -
COPPER
DOWNLIGHT
MANUFACTURERS ASSOCIATION
DEMO -
DEMOLITION
NFPA -
NATIONAL FIRE PROTECTION
CUSTOM CHANDELIER
150W
LED
120
ASSOCIATION
DISC -
DISCONNECT
NTS
V.
NF -
NON-FUSED
ECB -
ENCLOSED CIRCUIT BREAKER
120
AS APPROVED BY OWNER
INSTALLED BY ELECTRICIAN
NIC -
NOT IN CONTRACT
ELEC -
ELECTRICAL
NL -
NIGHT LIGHT
EM -
EMERGENCY
O.C. -
ON CENTER
EMS
ENERGY MANAGEMENT
-
SYSTEM
P -
POLE
EMT -
ELECTRICAL METALLIC TUBING
PNL -
PANELBOARD
EF -
EXHAUST FAN
PVC -
POLYVINYL CHLORIDE
ETR -
EXISTING TO REMAIN
REL -
RELOCATE
EX -
EXISTING
RGS -
RIGID GALVANIZED STEEL
FA -
FIRE ALARM
RM -
ROOM
FACP -
FIRE ALARM CONTROL PANEL
SPEC -
SPECIFICATION
FBC -
FLORIDA BUILDING CODE
SS -
STAINLESS STEEL
GFI -
GROUND FAULT INTERRUPTER
TP -
TAMPER PROOF
GND -
GROUND
TVSS -
TRANSIENT VOLTAGE SURGE
SUPPRESSION
GRC -
GALVANIZED RIGID CONDUIT
TYP _
TYPICAL
HVAC
-AIR
TNTINTING AND
CODICONDITIONING
UON -
UNLESS OTHERWISE NOTED
IWH
INSTANTANEOUS WATER
V -
VOLTS
-
HEATER
W -
WIRE
H.I.D. -
HIGH INTENSITY DISCHARGE
WP _
WEATHERPROOF
I.G. -
ISOLATED GROUND
J -
JUNCTION
TYPE
Ski MOM i"MEM
MANUFACTURER & CATALOG NO.
DESCRIPTION
VOLTAGE DROP
THIS PROJECT IS IN COMPLIANCE WITH
2014 FBC-ENERGY CONSERVATION
C406.7.3 AND NEC 210.19 WITH REGARDS
TO VOLTAGE DROP FOR BOTH
DISTRIBUTION PANELS (2%) AND
DOWNSTREAM BRANCH CIRCUITS (3%).
GENERAL NOTE:
THESE ELECTRICAL DESIGN HAS BEEN
DESIGNED IN ACCORDANCE WITH THE
2011 NATIONAL ELECTRICAL CODE.
LAMPS VOLTS OR APPROVED EQUALS BY
AFIXTURE
PROVIDED OWNER
1' x 4' DIMMABLE SURFACE MOUNTED
50W
LED
120
AS APPROVED BY OWNER
INSTALLED BY ELECTRICIAN
FIXTURE
_
v)
y*
w 4-J uj
FIXTURE PROVIDED OWNER
WALL WASH TRACK LIGHTING
LFD
120
AS APPROVED BY OWNER
rummumm
INSTALLED BY ELECTRICIAN
tJ
g
O o0
0
ll
LL co
Lo 0
¢
FIXTURE PROVIDED OWNER
EDISON PENDANT
1 0O
LED
120
AS APPROVED BY OWNER
INSTALLED BY ELECTRICIAN
D
FIXTURE PROVIDED OWNER
EDISON PENDANT
100W
LED
120
AS APPROVED BY OWNER
COPYRIGHT OF INTELLECTUAL PROPERTY,
INSTALLED BY ELECTRICIAN
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
EMERGI-LITE
COMBINATION LED EMERGENCY LIGHT/ EXIT
3.6W
120
AS APPROVED BY OWNER
ELXN400G-2LED
SIGN WITH INTEGRAL 90 MINUTE
LEDD
oC�1
EMERGENCY BATTERY PACK
0
Lij
EM
EMERGI-LITE:
LED EMERGENCY LIGHT WITH INTEGRAL
2W
120
AS APPROVED BY OWNER
EL-2LEDW
90 MINUTE EMERGENCY BATTERY PACK
LED
a�
e
F
FIXTURE PROVIDED OWNER
DIMMABLE SURFACE MOUNTED
1 0O
120
AS APPROVED BY OWNER
PROJECT NO: 16-2235
INSTALLED BY ELECTRICIAN
DOWNLIGHT
LED
2
3
G
FIXTURE PROVIDED OWNER
CUSTOM CHANDELIER
150W
LED
120
AS APPROVED BY OWNER
ELECTRICAL
INSTALLED BY ELECTRICIAN
NTS
V.
H
FIXTURE PROVIDED OWNER
DIMMABLE SURFACE MOUNTED DOWNLIGHT
25W
LED
120
AS APPROVED BY OWNER
INSTALLED BY ELECTRICIAN
LIGHTING FIXTURES SCHEDULE NOTES1
1. PROVIDE ALL DEVICES, MOUNTING EQUIPMENT, CHAIN, STRAIN RELIEFS, CLIPS, ESCUTCHEONS, PLATES AND
STRUCTURAL SUPPORTS FOR THE INSTALLATION AND CONNECTION OF ALL LIGHTING FIXTURES.
2. 2'X4' RECESSED LIGHTING FIXTURES SHALL BE SUPPORTED BY TWO 12 -GAUGE WIRES FROM PERMANENT
STRUCTURE. ALL RECESSED DOWNLIGHTS SHALL BE SUPPORTED BY ONE 12 -GAUGE WIRE CONNECTED TO
STRUCTURE.
3. ALL LAMPING COLOR TEMPERATURE SHALL BE 3500K FOR ALL LIGHTING FIXTURES.
4. ALL COMPACT FLUORESCENT LIGHTING FIXTURES SHALL UTILIZE ELECTRONIC BALLASTS.
5. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FINAL LOCATION OF LIGHTING FIXTURES.
6. COORDINATE THE ACTUAL TYPE OF CEILING FOR EACH FIXTURE WITH ARCHITECTURAL REFLECTED CEILING
PLANS AND PROVIDE FIXTURE TRIM AS REQUIRED.
DOTE: PROVIDE ALL REQUIRED MOUNTING HARDWARE AND WIRING TO CONNECT LIGHTING FIXTURES AT
10LLOW CORE SLAB LOCATIONS INCLUDING BOXES, HANGER BARS, STRUCTURAL APPROVED
ASTENER'S AND UL APPROVED CONNECTORS.
CA# 26308 117094.00
4798 NEW BROAD STREET
- SUITE 300
ORLANDO, FL 32814
407.398.6007 (P)
40/ 398.6003 (F)
'Prco:iireEry encgS."'wkws,
9 rlclineers,Aulogmi
.
QD T
0
o
r,
f
_
v)
y*
w 4-J uj
_m C)
0
o
In
rummumm
O
tJ
g
O o0
0
ll
LL co
Lo 0
¢
Y` o
N t 11 .11•C'
_
I
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
\\\\�Illitli/���
\ ��
No, - 301
,o
STA
P
5/���AI�������\
oC�1
LL!
0
Lij
ILL
Z w Q-
cr
0
r- LL
w U)
Li
N
a�
e
z
U
.a
4
SHEET INFORMATION
DAA: 0612612017
DRAWN BY: DRN
PROJECT NO: 16-2235
REVIEWED BY: JOH
® Plan Revisions Date:
2
3
4
5
6
7
8
Sheet Name
ELECTRICAL
LEGEND,
NTS
V.
i
I
0
I
I
I
I
.A I I R # [4,
A. THE CONTRACTOR SHALL VISIT AND CAREFULLY EXAMINE THOSE
PORTIONS OF THE BUILDING AND SITE AFFECTED BY THIS WORK
BEFORE SUBMITTING PROPOSAL SO AS TO BECOME FAMILIAR WITH
EXISTING WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED
AS EVIDENCE. THAT SUCH EXAMINATION HAS BEEN MADE AND LATER
CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE
BY DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. IT IS TO
BE UNDERSTOOD THAT UNFORESEEN CONDITIONS PROBABLY EXIST
AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN
ON THE DRAWINGS. COOPERATION WITH OTHER TRADES IN
EQUIPMENT ROUTING AS DETERMINED DURING CONSTRUCTION AND
AS DIRECTED BY THE ARCHITECT/ENGINEER MAY BE NECESSARY
AND IT IS INTENDED THAT SUCH DEVIATIONS SHALL BE CONSIDERED
AS PART OF THIS CONTRACT. IT IS ALSO UNDERSTOOD THAT THE
PLANS ARE NOT COMPLETELY TO SCALE. THIS CONTRACTOR IS TO
FIELD VERIFY DIMENSIONS OF ALL EXISTING CONDITIONS, PRIOR TO
BID AND INCLUDE ANY DEVIATIONS IN THE CONTRACT.
B. ALL DEVICES AND EQUIPMENT NOT SHOWN AND IN AREAS OUTSIDE
OF REMODELING SHALL REMAIN ACTIVE UNLESS OTHERWISE NOTED.
INSTALL AS REQUIRED TO MAINTAIN CONTINUITY TO EXISTING
DEVICES AND EQUIPMENT THAT ARE TO REMAIN.
C. ALL EQUIPMENT AND MATERIAL REMOVED SHALL BE LEGALLY
DISPOSED OF BY THE CONTRACTOR.
D. ALL ELECTRICAL DEVICES THAT ARE REMOVED SHALL BE REMOVED,
AND CEILING OR WALL SHALL BE PATCHED TO MATCH EXISTING OR
NEW FINISH. ALL PATCHES OR CEILING PLATES SHALL BE PATCHED
OR PAINTED AS DIRECTED BY ARCHITECTURAL DRAWINGS.
E. ALL EXISTING ELECTRICAL EQUIPMENT IS NOT SHOWN. IT IS THE
CONTRACTORS RESPONSIBILITY TO BECOME FAMILIA WITH ALL
EXISTING CONDITIONS PRIOR TO BID AND INCLUDE THE REMOVAL
OF ALL EQUIPMENT. CONDUIT, WIRE, ETC. THAT IS NOT BEING
REUSED BACK TO ITS SOURCE.
F. ALL CONCRETE, DRYWALL OR CONCRETE WALL PATCHING, CEILING
REPAIR, AND OTHER GENERAL WORK REQUIRED FOR INSTALLING THE
ELECTRICAL SYSTEMS AND TO REPAIR TO "LIKE NEW CONDITION" TO
BE PROVIDED AND INSTALLED BY THE CONTRACTOR.
G. PROVIDE AND INSTALL ANY ADDITIONAL HANGERS/SUPPORTS
REQUIRED TO ACCOMMODATE ANY EQUIPMENT RELOCATION.
H. COORDINATE ALL CEILING MOUNTED DEVICES WITH ARCHITECTURAL
REFLECTED CEILING AND WORK OF ALL OTHER TRADES.
I. FOR NEW ELECTRICAL DEVICES WITHIN EXISTING WALL PARTITIONS,
CONTRACTOR SHALL BE PERMITTED TO USE METAL CLAD CABLE IF
APPROVED BY AUTHORITY HAVING JURISDICTION. PROVIDE SUBMITTAL
PRIOR TO ROUGH—IN.
J. ITEMS NOTED AS EXISTING TO BE REMOVED SHALL BE REMOVED
COMPLETE, INCLUDING BUT NOT LIMITED TO ALL HANGERS,
SUPPORTS, CONDUITS, BOXES, FITTINGS AND WIRING. REMOVAL
SHALL INCLUDE CONDUIT AND WIRE BACK TO BRANCH PANEL.
NOTE -
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR 70
PERFORM CIRCUIT TRACING FOR ALL BRANCH CIRCUITS
CURRENTLY IN THE SCOPE OF WORK AND TO DOCUMENT ALL
AVAILABLE BRANCH CIRCUITS PRIOR TO CONSTRUCTION.
ELECTRICAL DEMOLITION PLAN_ i
1/4'1 = 11-0"
10 REMOVE ALL EXISTING POWER RECEPTACLES AND ASSOCIATED
WIRING, BOXES AND CONDUIT, IN THIS AREA, BACK TO CEILING
MOUNTED JUNCTION BOXES. UTILIZE EXISTING 120V 20A BRANCH
CIRCUITS FOR NEW POWER SCOPE OF WORK. REFER 'TO E-2.1
FOR EXACT NEW POWER REQUIREMENTS.
OZ REMOVE ALL DATA/COMMUNICATION AND LOW VOLTAGE DEVICES
AND ASSOCIATED WIRING, BOXES AND CONDUIT, IN THIS AREA
ONLY, BACK TO POINT OF ORIGIN, UNLESS NOTED OTHERWISE.
REMOVE ALL EXISTING 120V LIGHTING FIXTURES AND ALL
ASSOCIATED WIRING BACK TO CEILING MOUNTED JUNCTION BOXES.
UTILIZE EXISTING 120V 20A BRANCH CIRCUITS FOR NEW LIGHTING
SCOPE OF WORK, REFER TO ARCHITECT INTERIOR FINISH
SCHEDULE FOR EXACT LIGHTING FIXTURE PLACEMENTS, CONTROLS
AND SCOPE OF WORK.
® HVAC UNITS AND EXHAUST FAN AND ASSOCIATED FIRE ALARM
DEVICES FOR HVAC UNITS ARE TO BE EXISTING AND SHALL REMAIN
CONNECTED FOR RE—USE.
O5 UNLESS OTHERWISE NOTED TRACE EXISTING CIRCUITRY AND
RE—USE AS MUCH AS POSSIBLE. CONTRACTOR SHALL CONFIRM
O OPERATION OF EXISTING DEVICES.
6
ITEMS NOTED TO BE THE ETR SHALL BE EXISTING TO REMAIN.
RECIPIENT AS INDICATED ON DRAWING E2.1. FIRE ALARM DEVICE
SHALL BE RECONNECTED AND RETESTED
IN 1,
�.
i
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
Al THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
a
z
a
n
SHEET INFORMATION
DATE: 0612612017
DRAM BY. ORN
PROJECT NO, 16-2235
REVIEWED BY: XH
wl Plan Revisions Date:
Sheet
.., iT,=R mwTLCTE-D fes.. -
TON M340 8EFIE8 OR EQUAL,
336 SWIVEL BA8E—\
END FRONT
'•44/3 80 CABLE —
(30 FEET LONW
'.;
W
P11713 -17-
P1 176-19
117B-17P117B-19
2
r.
EXISTING L
SERVICE
ENTRANCE
1 O 2
I P117B-23�
5
X. PANEL HWRP-1
"P117A"i
_ _ r IP117B-13
N.EW,,PANEL COa
"P1 11713" -� 1
E _Q, mM,
1
GLYCOL
ETR
FLY
12 I,
P1
I
(91C
_ 0
EM
2 -POLE TIMECLOCK
INTERMATIC OR EQUAL
TYP. BRANCH CIRCUIT
NUMBER
P1 17A-1 P1 17A-3 PI 17A-5 PI 17A-6
LIGHTING CONTACTOR SHALL BE
INSTALLED AND PROGRAMMED IN
COMPLIANCE WITH 2014 FBC
SPARE SPARE ENERGY CONSERVATION SECTION
.� C405.2.1.2. AUTOMATIC LIGHTING
H I CONTROL SHALL BE CAPABLE
120V 20AMP W.P. OVERRIDE OF OVERRIDING ANY TIME OF
P117A-34 TOGGLE SWITCH LOCATED T T DAY SCHEDULED SHUT OFF
ADJACENT TO PANEL "PI 17A" CONTROL FOR NO MORE THAN
IN LOCKABLE ENCLOSURE. TWO HOURS.
N
P1176-15
15 A
5 /ETR
�17
EM
C& C@5
5
LIGHTING CONTACTOR LC -1
20AMP 6 POLE NEMA 1
ELECTRICALLY HELD.
—Y J MOUNT ADJACENT TO
TO INTERIOR LIGHTING FIXTURES PANEL "PI 17A"
INTERIOR LIGHTING CONTROL DIAGRAM 1L -l't
NTS
5 �15�- 17 -, �.. 17 � 7Al7-7�I"U B. ,.44 .0B. �.U 8... t.t._B
17
G
j.
.427'
°FTR
C®5 C@6 Cad C(i)6
I .,.
.1 5 ;mll
,, iUS,,
01
x
C
35
1 � ... ,d
Fry F
D O1
Sp
( 23 `
PROJECTOR'S
��� ,,.
uu...M P117B 3 5
c
)
d d d
c 1 ,_ 0 O
2800 3000 OWP I 5�`
6 6 6�
.. `.
ERR
3
P1,176-1 .. D.. w w .°.., ...... 19
pwP . _. .
EF M 5 6 5
WPO �17'11 B E
P117B-11 P1 17B-7.9 l>,
ELECTRICAL PLAN
1/4" = 1 I-011
GLYCO
L110
' 16,18,20 12
N25
t
C d
51
C d
_ �6
- V V
23 `44�r ``4Q''
� ��i
6..
GENERALNOTES
1. ALL BRANCH CIRCUITS SHALL BE CONNECTED TO PANEL
"P117A" UNLESS OTHERWISE NOTED.
2. ALL LIGHTING FIXTURES SHALL COMPLY WITH NEC 410.130.
3. ALL EMERGENCY AND EXIT LIGHTING SHALL BE CONNECTED
AHEAD OF ANY SWITCHING ARRANGEMENTS OR CONTROLLED
BY A LISTED UL924 CONTROLLER PER N.E.C.
4. THIS PROJECT IS IN COMPLIANCE WITH 2014 FBC-ENERGY
CONSERVATION C405.7.3 AND NEC 210.19 WITH REGARDS TO
VOLTAGE DROP FOR BOTH DISTRIBUTION PANELS (2%) AND
DOWNSTREAM BRANCH CIRCUITS (3%).
5. REFER TO ARCHITECTURAL LIGHTING PLANS FOR ANY AND
ALL LIGHTING FIXTURE MOUNTING DIMENSIONS.
6. SEAL ALL FIRE WALLS, ROOF, AND FLOOR PENETRATIONS
WITH UL LISTED FIRE SEALANT.
R E F E R E N"(; E N`0 T E!, 13"
�1 PROVIDE 20A CORD REEL ASSEMBLY. COORDINATE WITH
OWNER FOR EXACT LOCATION. REFER TO DETAIL ON THIS
SHEET FOR ADDITIONAL INFORMATION. PROVIDE STRUCTURAL
SUPPORT TO SUPPORT WEIGHT OF CORD REEL PLUS 200%
ADDITIONAL.
® CONNECT EXHAUST FAN EF -1 TO LIGHTING BRANCH CIRCUIT.
PROVIDE (1) 120V 20A BRANCH CIRCUIT IN JUNCTION BOX
AND (1) 208V 20A BRANCH CIRCUIT AND W.P. DISCONNECT
SWITCH IN CEILING FOR COOLER EVAPORATOR COIL. PROVIDE
SEAL IFF AS REQUIRED.
® PROVIDE 120V 20A BRANCH CIRCUIT AND JUNCTION BOX IN
CEILING FOR COOLER DOOR HEATER AND LIGHTING. PROVIDE
CONDUIT SEAL -OFF FITTINGS FOR TEMPERATURE
DIFFERENTIAL PER NEC. VERIFY THE EXACT LOCATION OF
DISCONNECT SWITCHING PRIOR TO ROUGH -IN.
O IN ACCORDANCE WITH NEC 427.22, PROVIDE GROUND FAULT
PROTECTION OF EQUIPMENT TO COOLER ELECTRICAL DEVICES
DUE TO FLAT SURFACES OUTSIDE OF THE COOLER
GENERATING HEAT AND TRANSFERRING THE HEAT.
© PROVIDE RACEWAY SEALING WHERE CONDUIT PASES FROM
WARM TO COLD LOCATION. LOCATE FITTINGS AT SUITABLE
LOCATIONS AND FILL WITH A UL LISTED SEALING COMPOUND.
O7 PROVIDE USB COMBINATION RECEPTACLE.
® TELEPHONE TERMINAL BOARD PROVIDE 4'X8', 3/4" PLYWOOD
WITH FIRE RATED PAINT.
® RECEPTACLE IS TO BE HALF CONTROLLED AND TIED INTO
OCCUPANCY SENSOR WHICH CONTROLS THE SPACE.
RECEPTACLES TO P&S RF RECEPTACLES AND SIGNAL PACK
OR SIMILAR.
1p LC -1 MOUNTED ADJACENT PANEL P1178
yrru ...ev,g.m
(D
•xa�YIL':! �' Lle1
to «
vLLL
CIO
'u
Lu
o
o0
0
mr
win
LLI
c co V)
� aFh B #a ij . w
0
LL C0
o
y
C'.
(n O
U)¢o
N (If I1•(•
t P
� �d _
jj Yiy
1111
�;y I
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
C a
73015
'• S T �r '� 4q
0 R I D_ ':. N����1.
G
!!1! 11
uj
I
0 cy)
Lu
a-
Lj...
z w
'--'
0
C�9 LL
LmLmj
u
a
'L
IL
SHEET INFORMATION
DATE: 06/2612017
DRAWN BY: DRN
PROJECT NO: 16-2235
REVIEWED BY: JOH
Plan Revisions Date:
.I
2
3
4
5
6
7
8
Sheet Name
ELECTRICAL
PLAN
E2. 1
_.... _L..11. JI
1. ALL INSTALLATIONS AND EQUIPMENT SHALL BE IN STRICT ACCORDANCE
WITH ALL APPLICABLE STATUTES, CODES AND REGULATIONS OF THE
GOVERNMENTAL BODIES HAVING JURISDICTION. THIS SET OF PLANS IS
DESIGNED TO BE IN ACCORDANCE WITH FLORIDA PLUMBING CODE 2014
EDITION WITH SUPPLEMENTS.
2. ALL DRAINAGE PIPING OVER 2" IN DIAMETER SHALT_ HAVE A 1/8" PER
FOOT SLOPE AND ALL DRAINAGE PIPING 2" OR LESS IN DIAMETER SHALL
HAVE A 1/4" PER FOOT SLOPE UNLESS OTHERWISE NOTED.
3. ALL DRAINAGE PIPING SHALL BE MARKED WITH THE SEAL OF APPROVAL
OF THE NATIONAL SANITATION FOUNDATION.
4. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO WHICH
NEW SEWER LINES ARE TO BE CONNECTED BEFORE INSTALLATION OF
NEW SEWER LINE.
M
=-
PLUMBING SPECIFICATIONS
PART 1
GENERAL
PART 2
PRODUCTS
1.1 SECTION INCLUDES
2.1 PIPE
HANGERS AND SUPPORTS
A.
GENERAL PROVISIONS SPECIFICALLY APPLICABLE TO DIVISION 15 SECTIONS,
A.
MANUFACTURERS:
��-
IN ADDITION TO DIVISION 1 - GENERAL REQUIREMENTS.
C
CAPPED LINE
G
GAS
- - -G - - -
1. B -LINE
1.2 SCOPE
SANITARY SEWER (ABOVE GRADE)
- -SAN- -
SANITARY SEWER (BELOW GRADE)
ST
STORM SEWER (ABOVE GRADE)
2. OTHER ACCEPTABLE MANUFACTURERS OFFERING EQUIVALENT
A.
THE WORK SHALL INCLUDE THE PROVISIONS OF SYSTEMS,
SECONDARY STORM SEWER (ABOVE GRADE)
PRODUCTS.
DOMESTIC COLD WATER
EQUIPMENT AND MATERIALS SPECIFIED IN THIS DIVISION AND AS
DOMESTIC HOT WATER
HWR-
DOMESTIC HOT WATER RETURN
CALLED FOR ON THE DRAWINGS. WORK SHALL ALSO INCLUDE
FILTERED WATER
A) MICHIGAN HANGER.
CONDENSATE DRAIN (ABOVE GRADE)
SUPERVISION, OPERATION, METHODS AND LABOR FOR THE
CONDENSATE DRAIN (BELOW GRADE)
----------
VENT
FABRICATION, START-UP AND TESTS FOR A COMPLETE OPERATIONAL
POINT OF CONNECTION NEW
B) PHD.
TO EXISTING
PLUMBING INSTALLATION.
POINT OF REMOVAL FOR DEMOLITION
HB Z-
HOSE BIBB
FD 8
2.2 HOT
WATER PIPING INSULATION
B.
DRAWINGS FOR THE WORK ARE DIAGRAMMATIC IN NATURE AND ARE
FLOOR CLEANOUT
--rA
CLEANOUT
INTENDED TO CONVEY THE SCOPE OF THE INSTALLATION AND TO INDICATE
A.
MANUFACTURERS:
HORIZONTAL CLEANOUT
THE GENERAL ARRANGEMENT AND LOCATIONS OF THE WORK. BECAUSE OF
SHOCK ABSORBER
NOT TO SCALE
PSI
THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS SUCH AS PIPE
PVC
1. OWENS-CORNING
R
FITTINGS, ACCESS PANELS, AND SLEEVES MAY NOT BE SHOWN. THIS
REQ'D
REQUIRED
RM
CONTRACTOR SHALL BE RESPONSIBLE FOR SELECTING THE EQUIPMENT TO
SAN
2. JOHNS -MANVILLE
SPEC
FIT THE SPACE PROVIDED. THE LOCATION AND SIZES FOR PIPE FITTINGS,
TEMP
TEMPERATURE
TYP
SLEEVES, INSERTS, FIRE AND/OR SMOKE DAMPERS, AND OTHER BASIC
V
3. KNAUF
VTR
ITEMS REQUIRED BY CODE AND OTHER SECTIONS SHALL BE COORDINATED
W/
WITH
WCO
AND INCLUDED FOR THE PROPER INSTALLATION OF THE WORK.
B.
ASTM C547, RIGID MOLDED NON-COMBUSTIBLE FIBERGLASS INSULATION.
'K' VALUE .024 ® 75 DEGREES F.
C.
EQUIPMENT SPECIFICATIONS MAY NOT DEAL INDIVIDUALLY WITH MINUTE
ITEMS REQUIRED SUCH AS COMPONENTS, PARTS, CONTROLS AND DEVICES
C.
VAPOR BARRIER JACKET, KRAFT PAPER WITH GLASS FIBER YARN AND
WHICH MAY BE REQUIRED TO PRODUCE THE EQUIPMENT PERFORMANCE
BONDED TO ALUMINUM FILM. CLOSURE SYSTEM SHALL BE UL 181.
SPECIFIED OR AS REQUIRED TO MEET THE EQUIPMENT WARRANTIES. WHERE
SUCH ITEMS ARE REQUIRED, THEY SHALL BE INCLUDED BY THE INSTALLER
D.
INSULATION THICKNESS 1-1/2"
OF THE EQUIPMENT, WHETHER OR NOT SPECIFICALLY INDICATED IN THE
CONTRACT DOCUMENTS WITH NO ADDITIONAL COST INCURRED.
2.3 SANITARY SEWER, ABOVE AND BELOW GRADE:
D.
WHERE NOTED ON THE DRAWINGS OR INDICATED IN OTHER SECTIONS OF
A.
CAST IRON: CISPI 301, SERVICE WEIGHT, NO HUB.
THE SPECIFICATION, THE CONTRACTOR FOR "THIS DIVISION SHALL INSTALL
PLUMBING EQUIPMENT FURNISHED BY OTHERS, AND SHALL MAKE ALL
1. FITTINGS: CISPI 301 CAST IRON DWV.
FINAL CONNECTIONS. CONTRACTOR SHALL INSTALL EQUIPMENT AND
SYSTEMS IN STRICT ACCORDANCE WITH MANUFACTURERS
2. JOINTS: CISPI 301 STAINLESS STEEL CLAMPS, MINIMUM 24 GA. WITH
RECOMMENDATIONS.
NEOPRENE GASKET, HUSKEY SERIES 4000 OR CLAMP -ALL ONLY.
E.
COORDINATE WITH ALL TRADES IN SUBMITTAL OF SHOP DRAWINGS. TIGHT
2.3 VENT
PIPING, ABOVE GRADE:
SPACE CONDITIONS SHALL BE DETAILED TO THE SATISFACTION OF ALL
TRADES, SUBJECT TO THE REVIEW AND FINAL ACCEPTANCE OF THE
A.
PVC: ASTM D2665 SCHEDULE 40 PVC PIPING.
ARCHITECT/ENGINEER. IN THE EVENT THAT THE CONTRACTOR INSTALLS HIS
WORK BEFORE COORDINATING WITH OTHER TRADES OR SO AS TO CAUSE
1. FITTINGS: ASTM D2665 SCHEDULE 40 PVC DWV FITTINGS.
ANY INTERFERENCE WITH THE WORK OF THE OTHER TRADES THIS
CONTRACTOR SHALL MAKE ALL REQUIRED CHANGES TO CORRECT THE
2. JOINTS: ASTM D2564 SOLVENT CEMENT. JOINTS SHALL BE
CONDITION AT NO ADDITIONAL COST TO THE PROJECT.
INSTALLED IN ACCORDANCE WITH ASTM D2855.
F.
CONTRACTOR SHALL VERIFY ALL EQUIPMENT CONNECTION SIZES PRIOR TO
2.4 WATER
PIPING, ABOVE GRADE:
INSTALLATION OF ANY SYSTEMS. THIS CONTRACTOR SHALL ADJUST PIPING
SYSTEM SIZES AS REQUIRED TO MATCH EQUIPMENT CONNECTIONS. UTILIZE
A.
COPPER PIPING: ASTM B88 TYPE 'L' HARD DRAWN.
REDUCERS WHERE EQUIPMENT CONNECTIONS ARE SMALLER THAN PIPE
SIZES INDICATED ON PLANS, NO PIPING SHALL BE DECREASED IN SIZE (IN
1. FITTINGS: ASME 16.18 CAST BRONZE OR ASME B16.22 WROUGHT
THE DIRECTION OF FLOW).
COPPER OR BRONZE.
2
G.
EXAMINATION OF BIDDING DOCUMENTS:
JOINTS: ASTM B32 SOLDER, ASTM 95-5 TA MINIMUM, FLUX ASTM
B813. JOINTS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM
1. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS CAREFULLY
6828•
AND NOT LATER THAN TEN (10) DAYS PRIOR TO THE DATE FOR
RECEIPT OF BIDS, SHALL MAKE WRITTEN REQUEST TO THE ENGINEER
2.5 WATER
PIPING, BELOW GRADE & OUTSIDE BUILDING:
FOR INTERPRETATION OR CORRECTION OF ANY AMBIGUITY,
INCONSISTENCY OR ERROR THEREIN. ANY INTERPRETATION OR
A.
CPVP, PIPING &FITTINGS: ASTM D1784 PIPE COMPOUND CELL CLASS
CORRECTION WILL BE ISSUED AS AN ADDENDUM BY THE ENGINEER.
24418.
ONLY A WRITTEN INTERPRETATION OR CORRECTION TO BID
DOCUMENTS BY ADDENDUM SHALL BE BINDING. NO BIDDER SHALL
1. JOINTS: ASTM F493 SOCKET TYPE WITH SOLVENT CEMENT ASTM F402 N.
RELY UPON ANY INTERPRETATION OR CORRECTION GIVEN BY ANY
INTERNATIONAL APPROVED MFG. COMPATIBLE.
OTHER METHOD.
2. FLOWGUARD GOLD CPVC PIPE AS MFG. BY NOVEON INC.
H.
SUBSTITUTIONS:
1. EXCEPT AS PROVIDED BELOW, EACH BIDDER REPRESENTS THAT HIS
2.6 GAS
PIPING, ABOVE GRADE:
BID IS BASED UPON THE MATERIALS AND EQUIPMENT DESCRIBED IN
THE BIDDING DOCUMENTS.
A.
SCHEDULE 40 BLACK STEEL.
2, NO SUBSTITUTIONS FOR OTHER MATERIALS AND EQUIPMENT WILL BE
1, ASME STEEL FITTINGS.
CONSIDERED UNLESS WRITTEN REQUEST HAS BEEN SUBMITTED TO
THE ENGINEER FOR APPROVAL AT LEAST TEN (10) DAYS PRIOR TO
B.
COPPER PIPING: ASTM B88 TYPE 'L' HARD DRAWN.
THE DATE FOR RECEIPT OF BIDS. EACH SUCH REQUEST SHALL
INCLUDE A COMPLETE DESCRIPTION OF THE PROPOSED SUBSTITUTE,
1. FITTINGS: ASME 16.18 CAST BRONZE OR ASME B16.22 WROUGHT
THE NAME OF THE MATERIAL OR EQUIPMENT FOR WHICH IT IS TO
COPPER OR BRONZE.
BE SUBSTITUTED, DRAWINGS, CUTS, PERFORMANCE AND TEST DATA
OR INFORMATION NECESSARY FOR A COMPLETE EVALUATION.
2, JOINTS: ASTM B32 SOLDER, ASTM 95-5 TA MINIMUM, FLUX ASTM
B813. JOINTS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM
3. IF THE ENGINEER APPROVES ANY PROPOSED SUBSTITUTION, SUCH
B828.
APPROVAL WILL BE ISSUED AS AN ADDENDUM FORWARDED TO ALL
PARTICIPATING BIDDERS.
PART 3
INSTALLATION
4. IF ANY BIDDER IS UNABLE TO PROCURE WRITTEN APPROVAL OF ANY
A.
INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S
SUBSTITUTION FROM THE ENGINEER PRIOR TO THE OPENING OF
BIDS, THEN HE SHALL BASE HIS BID ON ITEMS AND SYSTEMS AS
INSTRUCTIONS.
SPECIFIED IN BID DOCUMENTS.
B.
PROVIDE NON -CONDUCTING DIELCTRIC CONNECTIONS WHEREVER
5. SUBSTITUTIONS REQUESTED ON THE BID PROPOSAL FORM WHICH
JOINTING DISSIMILAR METALS.
ARE PRIOR APPROVED BY THE ENGINEER WILL BE INCORPORATED
C.
ROUTE PIPING IN ORDERLY MANNER AND MAINTAIN GRADIENT.
INTO THE CONTRACT WITH THE SUCCESSFUL BIDDER.
6. REQUESTS FOR ANY SUBSTITUTIONS NOT SUBMITTED AND APPROVED
D.
INSTALL PIPING "TO CONSERVE BUILDING SPACE AND NOT
IN ACCORDANCE WITH THE ABOVE INSTRUCTIONS WILL BE DENIED BY
INTERFERE WITH USE OF SPACE.
THE ENGINEER.
E.
GROUP PIPING WHENEVER PRACTICAL AT COMMON ELEVATIONS.
1.3 REGULATORY REQUIREMENTS
F.
INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION
A.
ALL INSTALLATIONS AND EQUIPMENT SHALL BE IN STRICT ACCORDANCE
WITHOUT STRESSING PIPE, JOINTS, OR CONNECTED EQUIPMENT.
WITH ALL APPLICABLE STATUTES, CODES AND REGULATIONS OF THE
G.
PROVIDE CLEARANCE FOR INSTALLATION OF INSULATION AND ACCESS TO
GOVERNMENTAL BODIES HAVING JURISDICTION.
VALVES AND FITTINGS.
1.4 CUTTING AND PATCHING
H.
PROVIDE ACCESS WHERE VALVES AND FITTINGS ARE NOT EXPOSED.
COORDINATE SIZE AND LOCATION OF ACCESS DOORS WITH APPROPRIATE
A.
SUBMIT WRITTEN REQUEST IN ADVANCE OF CUTTING OR ALTERING
ARCHITECTURAL SECTION.
ELEMENTS.
I.
ESTABLISH ELEVATIONS OF BURIED PIPING OUTSIDE THE BUILDING TO
B.
EMPLOY SKILLED AND EXPERIENCED INSTALLER TO PERFORM CUTTING
ENSURE PROPER SLOPE AND COVER.
AND PATCHING WHICH EFFECT:
J.
ESTABLISH ELEVATIONS OF EXISTING BURIED PIPING FOR CONNECTION TO
1. INTEGRITY OF WEATHER PROOFING MATERIALS.
NEW WORK TO ENSURE PROPER SLOPE AND COVER. .
2. EFFICIENCY, MAINTENANCE, OR SAFETY OF ELEMENT.
K.
WHERE PIPE SUPPORT MEMBERS ARE WELDED TO STRUCTURAL BUILDING
FRAMING, SCRAPE, BRUSH CLEAN, AND APPLY ONE COAT OF ZINC RICH
3. VISUAL QUALITIES OF SIGHT.
PRIMER TO WELDING.
4. WORK OF OWNER OR SEPARATE CONTRACTOR.
L.
EXTEND CLEANOUTS TO FINISHED FLOOR OR WALL SURFACE. LUBRICATE
THREADED CLEANOUT PLUGS WITH MIXTURE OF GRAPHITE AND LINSEED
C.
NO STRUCTURAL ELEMENTS TO BE CUT WITHOUT PRIOR APPROVAL OF THE
OIL. ENSURE CLEARANCE AT CLEANOUT FOR RODDING OF DRAINAGE
ARCHITECT.
SYSTEM.
M.
INSTALL WATER HAMMER SHOCK ARRESTORS AT EACH FIXTURE OR BATTERY
OF FIXTURES WHERE REQUIRED. -ARRESTORS SHALL BE FACTORY
FABRICATED. INSTALL ARRESTORS AND SIZE PER PLUMBING AND DRAINAGE
INSTITUTE STANDARD P.D.I. WH -201. ACCEPTABLE MANUFACTURERS ZURN,
JOSAM, SIOUX CHIEF. PPP INC. FOR 1-11 FU'S PROVIDE PDI -A, FOR
12-32 FU'S PDI -B, 33-60 FU'S PDI -C, 61-113 FU'S PDI -D.
1. ALL INSTALLATIONS AND EQUIPMENT SHALL BE IN STRICT ACCORDANCE
WITH ALL APPLICABLE STATUTES, CODES AND REGULATIONS OF THE
GOVERNMENTAL BODIES HAVING JURISDICTION. THIS SET OF PLANS IS
DESIGNED TO BE IN ACCORDANCE WITH FLORIDA PLUMBING CODE 2014
EDITION WITH SUPPLEMENTS.
2. ALL DRAINAGE PIPING OVER 2" IN DIAMETER SHALT_ HAVE A 1/8" PER
FOOT SLOPE AND ALL DRAINAGE PIPING 2" OR LESS IN DIAMETER SHALL
HAVE A 1/4" PER FOOT SLOPE UNLESS OTHERWISE NOTED.
3. ALL DRAINAGE PIPING SHALL BE MARKED WITH THE SEAL OF APPROVAL
OF THE NATIONAL SANITATION FOUNDATION.
4. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO WHICH
NEW SEWER LINES ARE TO BE CONNECTED BEFORE INSTALLATION OF
NEW SEWER LINE.
M
=-
DIRECTION OF FLOW IN PIPE
-�"
PITCH PIPE DOWN IN DIRECTION OF ARROW
APPROX
U -O
PIPE UP
^, O
PIPE DOWN
--I�I--
BALL VALVE
BUILDING
CHECK VALVE, HORIZONTAL SWING
��-
GATE VALVE
C
CAPPED LINE
G
GAS
- - -G - - -
GAS UNDERGROUND
SAN
SANITARY SEWER (ABOVE GRADE)
- -SAN- -
SANITARY SEWER (BELOW GRADE)
ST
STORM SEWER (ABOVE GRADE)
- -ST- - -
STORM SEWER (BELOW GRADE)
SEC
SECONDARY STORM SEWER (ABOVE GRADE)
---CW---
DOMESTIC COLD WATER
----HW
DOMESTIC HOT WATER
HWR-
DOMESTIC HOT WATER RETURN
---FW---
FILTERED WATER
CD
CONDENSATE DRAIN (ABOVE GRADE)
- -CD- -
CONDENSATE DRAIN (BELOW GRADE)
----------
VENT
GALLONS PER MINUTE
POINT OF CONNECTION NEW
HOSE BIBB
TO EXISTING
HEAD
POINT OF REMOVAL FOR DEMOLITION
HB Z-
HOSE BIBB
FD 8
FLOOR DRAIN
HD O
HUB DRAIN
-
FLOOR CLEANOUT
--rA
CLEANOUT
®-
EXTERIOR CLEANOUT
NOT IN CONTRACT
HORIZONTAL CLEANOUT
n-�
SHOCK ABSORBER
AD
ACCESS DOOR
AFF
ABOVE FINISHED FLOOR
APPROX
APPROXIMATELY
ARCH
ARCHITECTURAL
AUTO
AUTOMATIC
BLDG
BUILDING
CD
CONDENSATE DRAIN
CLG
CEILING
CO
CLEAN-OUT
COND
CONDENSATE OR CONDENSER
CONT
CONTINUATION
CMU
CONCRETE MASONRY UNIT
CW
COLD WATER (CITY)
EL
ELEVATION
ELEC
ELECTRIC
EEW
EMERGENCY EYE WASH
'F
DEGREES FAHRENHEIT
ECO
EXTERIOR CLEANOUT
FCO
FLOOR CLEANOUT
FD
FLOOR DRAIN
GAL
GALLONS
GPH
GALLONS PER HOUR
GPM
GALLONS PER MINUTE
HB
HOSE BIBB
HD
HEAD
HW
HOT WATER
HR
HOUR
INV
INVERT ELEVATION
LBS
POUNDS
MIN
MINIMUM
NC
NORMALLY CLOSED
NIC
NOT IN CONTRACT
NO
NORMALLY OPEN
NTS
NOT TO SCALE
PSI
POUNDS PER SQUARE INCH
PVC
POLYVINYL CHLORIDE
R
RISE
REQ'D
REQUIRED
RM
ROOM
SAN
SANITARY
SPEC
SPECIFICATION
TEMP
TEMPERATURE
TYP
TYPICAL
V
VENT LINE
VTR
VENT THRU ROOF
W/
WITH
WCO
WALL CLEANOUT
CA_ # 26308 117094.00
4798 NEW BROAD STREET
SUITE 300
ORLANDO, FL 32814
407.398.6007 (P)
407.398.6003 (F)
'Pn;�cYry E+y-^tin!j ,S;;diX7aS"
I
rigineers, incV
N (•11 I4-4
)
�4f5 3�'
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
"(HE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INT F� TIONAL LAW.
UM
MA
0.699'
a c,
LWks N.
Of
m
s�'� ` `�+ r�• hd U
��/!i!l911i1�
SHEET INFORMATION
DATE: 06126/2017
DRAWN BY: RB
PROJECT NO: 16-2235
REVIEWED BY: NW
vl Plan Revisions Date:
Sheet No.
9
"CW DN TO WC 4" SOIL DN
TIE VENTINTO 4' SOIL DN
2" VENT UP
'E 2 VENT UP
THE XISTI G VTR
_ _ .... �-.. �- ° ..:.. ..°__. - .::.... ,.- . INV: - 7 _T ,." ..°µ_..
4 ..._..
t WC -2Q(,IC1�.,� I 1„ CW DN...T VVC « .. •...,. __ _...,"1 1,�-.,...u....
ECOt 1'
_...
4.'�77 O
4
AN— 7
1j" DOMESTIC WATER (48 WFU)(28 GPM)-- „I1 I „ 1 W
EMER " ENC/ ��
DRAIN: 3 I I 13 °
u..
CONNECT TO THE EXISTING WATER SERVICE.
FOR CONTINUATION SEE SITE PLAN
_I
u
-,�
7 —
��I{y"" EMERGENCY DRAIN
4„ I I 2 FDS 1 r ee 2 SIL DN --
NT
CW DN TO UR i
I ,, I C ..HW DTO LAV S,.,.
r... /
FOR CONTINUATION � •, R ,�, � N � � -^•-�
SEE SITE PLAN L-1 Fto- rt L-1 M ,.. _.....,�.....�...
WALL MOUNTED WATER HEATERS r '__� SHUT-OFF VALVEL.
(GWH-1 & GWH-2) .-{I. j�� --�:
(REFER TO PIPING DIAGRAMS) 41 HWRP-1-1i i -WCO 2„ WASTE DN
I 2 VENT UP
I" CW/HW THRU I r 1
WALL TO GWH-2
4 SAN (35 DFU) CONNECT TO THE ,; I �d t-•• - I'' "'
EXISTING SAN SYSTEM. VERIFY" CW/HW THRU I -s-' u 140' I 12 V -h, u* BALANCING VALVE I
TO I- s--� ---I �—--- I ,.
LOCATION PRIOR TO STARTING WORK. WALL T GWH-1 —_
,�- -I I I SET ®1 GPM �
0 (INV. EL. (-2.7 FT) ---I I ¢ is 4 I
°
Mme.'a
BELOW FIN. FLR. I.. .. ca u:.� .._,.:::�_ . fig: :... !; _,,.... m __.- _ __._ EN
14"i3" vTR
2" T U
it
„ - —HWR— —�--- - - - HW - - - - - HWf� — —I T'T•r
s-- 4„-- —� — a' �fl T
5—_.... ---SAN— -------- SAN--- -� -- 1------SAN----�I —� �C—O I
° >E' I --- --«- �M=x140'---------- ` --------s,�-140'.—__ ----- �— --14T _------------ ---140°i-I=4 „ a ,.
' I Fw — I —--------Fw -----!-----------------Fw ---1- ----- -- i-------Fw -- -- --- ' r W � I h
(INV. EL. (-2.23 FT) �r- . , >=x _ I -CW ---- «.- ----- - --- - - ----CW
BELOW FIN. FLR. „ S 1 F< r I.. —.. , „
2 WASTE DN c, ---- �--- CW-- I x” I I „ TRAP I �3
I I 1
` ' I �I 4' 4 f „ _wti. 3' FS „ - l
SAMPLING BOX (REFER 2 VENT UP—
,r- -----___1_� ( I I {.3-::...._. r I Iy ,, J CVS/HW IDN..tfO S-3
D THIS E I BALANCING VALVE I I 4 " ---
�� EVAP I J
/ b .�: ° „ 1„ S ®1 GPM 1" _ / L __ — — —I I I S-3
„ CW HW DN TO S-1 `"`�(' "� . I I o I
BREWERY SAMPLING PORT I I „� „{ _.� I p
€ I I 1 I 4y �_ COND. DRAIN TO FS -1 1 ;PIP "..,'3 COM
(REFER TO DETAIL THIS SHEEP) I , II'� I I I U 1 I TERMINATE W/2 AIR GAP i0� 5=2 SIN & WAS
2 „ I„ I I I':. :.w1 3 FS -1 I <? # I MINATE V
--- - 1 „
I PIPE 3 COMPARTMENT SINK TO `- ~~ i CW/H )N° -T0 S 2
12 WAY CO 4 FS -1 TERMINATE W/4" AIR GAP-
7II S -4°"e 2 vi I I
CW/HW DN TOS -4
I I
` I I I ova
I ' ' I ,
TD -1,
I
it
2„ VENT UP AT 45' ANGLE i I
14 14" (INV. EL. (-2.0 FT)
1
I BELOW FIN. FLR.
180' HWFD-,'B
DN TO HBI
e -i,
CW DN
________________ -�
' y T' -
— 3"
--
TO NB --�-� I
�U
�..✓r ,
M -1"'""" J" CW/HW DN TO MS -1
- ..1�"..,°GAS DN -WITH •SERVICE,..VALVETO � .��. �..,.�.� .... ..°....-_...�..�...,..,Y
DOMESTIC WATER FILTER �•�«�"°� —'°---"`"`-PRESSUR� REGULATORS•='(•2.°IREQ.D)
(REFER TO SCHEDULE) ENT. GAS PRESS. LESS THAN 2 PSI
OUTLET PRESS. 7 INCHES WC, 180
Ff3 FLOW RATE EACH.
1 PLUMBING PLAN
1j" CW DN W/BACKFLOW I/4" - 1'-0"
PREVENTER TO WATER FILTERING P2.1 -
SYSTEM
Al
26"0 HEAVY DUTY MANHOLE COVER
& FRAME (TRAFFIC DUTY)
PRECAST CONCRETE FLAT TOP
DESIGN DATA & GEN. NOTES
PRECAST;;'
CONCRETE 1. CONCRETE STRENGTH 5000 PSI @ 28 DAYS. DEN. 150 PCF.
RISER -,,2. CEMENT -PORTLAND TYPE I/II PER ASTM C 150-92.
;•' 36' x 36 3, ADMIXURES & PLASTICIZERS PER ASTM C 260-86 & C 494-92.
;' co 36»
g 4. REINFORCING PER ASTM A615, GRADE 60 DOMESTIC. MIN. 11" COVER.
RUBBER BOOT WALLS, BASE, & TOP SLAB DESIGNED FOR HS -20 LOADING.
(TYPICAL
° 5. TOP OF SLAB SEALED W/BUTYL ROPE MASTIC.
6. MAX. 5'-0" OF EARTH COVER OVER SLAB.
' 7. REFER TO PLANS FOR REQUIRED INLET AND OUTLET PIPE SIZES.
z 8. INSTALL A BENCH & CHANNEL WITH A DROP OF 0.25"/FOOT FROM THE INLET TO OUTLET PER PLUMBING STANDARDS.
6 9. USE 6" PVC TYPE SDR35 TO FORM THE CHANNEL. BRACE DOWN PIPING WHILE CHANNEL IS FORMING.
6" GROUT TYP. . ; ° N 10. EPDXY COATE THE INSIDE & ALLOW TO EMOWIOR TO INSTALLATION.
TYP..
s 12"
PRECAST OR CAST ° Itd' #4 ® 12" EACH WAY
PLACE CONCRETE BASE TOP FACE - 2" CLEAR
2 SAMPLING BOX
P2.1 NTS
CONCRET ALL AROUND THE TZSP-48
BODY AND EXTENSION COLLAR
EXTENSION COLLAR MODEL ECA -TZ -29 I �.
AS MANUFACTURED BY TRAPZILLA
FINISHED GRADE
1-7
� py" gg 9g
- ,_ '`•TIMI` 3�
"IM
}}jjI
�i } r-q{�'^p�`'�' , a .4 V� C ", +j.'�• .r9. �' f'��� p i �. ' �._»
`���.
!f.
OUTLET
SAMPLE PORT AS MANUFACTURED
A' ' 4 ro �.. BY TRAPZILLA MODEL TZSP-48
,
INSTALL SAMPLE PORT PER
MANUFACTURERS INSTUCTIONS
BREWERY SAMPLING FORT DETAIL
NTS
r
.Y
U)
c�
CU
I—
rv' o
V) 0
p ca h
C.,.) N to
U -i cnc•
cu C,
ro -o c
[: ai u= u
Mi R
g� 7
+ rr lti h �" vii o Y 0,1
0
�V aO.
.• s.�s�a?":. 2..>.13,awd.°,c33.u,+,r'1" ws''�c. `"".� OJ Q C
N [-U-D-V
� VQ -
re
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT• WffHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW,
CIENs.
fig
oLu
of rt
N
'U
Q
G
U
N
O
n.
SHEET INFORMATION
DATE: 08/11/2017
DRAWN BY: R8
PROJECT NO: 16-2235
REMEWED BY: Nm
VI Plan Revisions Date:
A"I 06/26/2017 PERMIT SET
2 07/26/2017 PERMIT COMMENTS
L 2 3 08/10/20177 PERMIT COMMENTS
Sheet Narnep
LZI..
CA# 26308 I17094.00
1798 NEW BROAD STREET
SUITE 300
ORLANDO, FL 32814
407.398.6007 (P)
407.398.6003 (F)
nul
" � ar(.xJ�Y: t yr,- is ri5•>trJnns..
i
i i'l� 1111�✓�ef ,7< Is ls.
10,
Sheet No.
w
FILTER
OUTLE
MAN
OUTLET
DRAIN LINE CONNECTI
DOMESTIC WATER FILTER DETAIL
INO SCALE
BYPASS VALVE
ORMALLY CLOSED)
ENTREATED WATER
INLET (F)
tNUAL
T VALVE
E 1.5 CONTROLLER
6" LONG
DIRT LEI
EQUIP.
6" LONG
DIRT LEG ---
THREADED CAP ---*-
TYPICAL GAS SUPPLY PIPE DROP DETAIL
NO SCALE
/-SHUT-OFF VALVE
UNION
VENT W/WEATHER ELBOW
EXTEND TO OUTDOORS
THREADED CAP
GAS PRESSURE REGULATOR
INSULATED FITTING
18" SHUT-OFF VALVE
APPROX. SEE VERTICAL PIPE
SUPPORT
DEl`AI L THIS�GV�
FINISHED FLOOR
TYPICAL GAS PRESSURE REGULATOR PIPING DETAIL
NO SCALE
IN-LINE CIRCULATING
THERMOMETER GAUGE PUMP SEE SPECIFICATION
(0-200 DEC) GWH-1
AQUASTAT FOR '* DIAL TYPE PRESSURE MOUNT GAS WATER HEATERS ON OUTSIDE
PUMP CONTROL GAUGE (0-100 PSIG) WALL WHERE SHOWN ON FLR PLANS.
GAUGE COCK INSTALL WATER HTRS PER
-- MANUFACTURES INSTALLATIONS
FLOW
0
- FOR CONTINUATION AND
SIZE, SEE FLOOR PLAN PRESSURE RELIEF VALVE _
PIPE TO 6" ABOVE FIN.
BALL VALVE -------/UNION CHECK VALVE GRADE DRAIN VALVE3" 14 BALL VALVE
REDUCING TEE (OR TEST (TYPICAL) '��� (i UP
-�)
PLUG FOR INSERTION OF - -
GAUGE) HOT WATER RECIRC. PULP DETAIL
NO SCALE THERMOMETER 1
44- NG �--s
>1
HW
3„
1/2" TRAP PRIMER SUPPLY FW
/-D
OMESTIC COLD WATER LINE 4 HW
(1 1/2" OR SMALLER)
� SUPPLY TO FIXTURES
SERVICE VALVE
NOTE: INSTALL LEVEL
TRAP PRIMER VALVE
INSTANTANEOUS HTR GWH-1 PIPING DIAGRAM
---
DISTRIBUTION UNIT
WATERPROOF FORMUTIPLE LINES
SEALANT (MAX. 4 LINES)
�1/2" TRAP PRIMER LINE
SLEEVE THRU
SLAB --,\\ \
/—FLOOR DRAIN
FLOOR SLAB
0 0 0
4 d 4 0 0 4 0 o a o
i o
SEALANT
BACKING
MATERIAL
TO MAIN BUILDING
WASTE DRAIN
TYPICAL TRAP SEAL PRIMER DETAIL
SCALE: NONE
SCALE: NONE
ANK
TYPICAL AL 3 COMPARTMENT SINK WASTE PIPING DETAIL
NO SCALE
SERVICE VALVE
(TYPICAL
HOT WATER INTLET tl-I—
LAV/HANDSINK MIXING
VALVE
6 L7, COLD WATER INTLET
TEMPERED WATER OUTLET
TYPICAL LAV/HANDSINK THERMOSTATIC FIXING VALVE
NO SCALE
w"
~i
G
H
--C
AIR GAP = 2 X "PIPE DIA.
FINISHED FLOOR(2" MIN.) d
FLOOR SINK a
• .d: J
A .. q ' d
q a d :d• d n �Y y .q.. v
q V•. 'q J.d ••4 d 4: q•,. .• •••qV'•'••
.4
dJ •'
d d
1' tl
J d% d. q `
16
4: v
INDIRECT WASTE RECEPTOR DETAIL
NOT TO SCALE
COVER -
ROUND CONCRETE COLLAR -
CONCRETE SURFACE OR FLOOR OINT TYPE 3/4" EXPANSION JOINT
COVERING AS REQUIRED PER SPECS W/JOINT SEAL—
CLEANOUT COVER C. 0. TEE CONCRETE
8„ 1»
CSK SCREW �
CLEANOUT PLUG CHROME PLATED
BRONZE WALL PLATE
FIN. SHED FLOOR
#3 BARS ALL AROUND(W/6" OVERLAP)
I CLEANOUT BO
CAULKING FERRULE X
SOIL OR WASTE SHORT LENGTH OF PIPE
FURNISHED W/CLEANOUT BOX-'
FLOOR PIPE RISEF-/
WALL STANDARD 1/8 BEND -
NOTE: PIPING AND JOINT TYPE PER
TYPICAL CLEANOUT DETAILS SPECIFICATIONS OR CONSTRUCTION STANDARD
SCALE: NONE
EXTERIOR
4" TYP.
TURF -
2"
r
�T/TTTl►�
CLEANOUT PLUG
` SPOUT BRACE
METAL EDGE
HOOK
SERVICE FAUCET WITH
VACUUM BREAKER
REMOVABLE S.S. STRAINER
& FRAME FURNISHED W/MS
CQ 1,
TYPICAL MOP SINK DETAIL
SCALE: NONE
GVVH-2
MOUNT GAS WATER HEATERS ON OUTSIDE
WALL WHERE SHOWN ON FLR PLANS.
INSTALL WATER HTRS PER
MANUFACTURES INSTALLATIONS
PRESSURE RELIEF VALVE _
PIPE TO 6" ABOVE FIN.
GRADE DRAIN VALVE---_,
(TYPICAL
BALL VALVE
L, �- TYP
L_ L -
THERMOMETER 1„
- NG
I IIA/
HWRP
T„
H W
SUPPLY TO FIXTURES
INSTANTANEOUS HTR GWH-2 PIPING DIAGRAM
SCALE: NONE
FW
CHECK VALVES
BALL VALVE SHUT—OF BALL VALVE SHUT—OFF
STRAINER ® UNION (TYPICAL)
REDUCED PRESSURE
RELIEF POR -r
ROUTE TO DRAIN —AIR GAP TYPE
18" A.F.F. MIN.
DRAIN FUNNEL
FIN. FLR.
REDUCED PRESSURE ZONE BACKFLOW
PREVENTOR DETAIL
SCALE: NONE
ANK
CA# 26308 117094.00
4798 NEW BROAD STREET
SUITE 300
jf,�
ORLANDO, FL 328'14
407.398.6007 (P)
407.398.6003 (F);� � 'Prca:c':oEn� ay.6rj r-;aira�a"
.1.9e roner 5, inc.
CEJ
U val;m
4-J LU
.�
0 LU
v)cr 0 ,
„3 W co
#.._
00
(T 1 m
�! (U M
m
R'7 x r--�• � C t0 C7
�s 0
i
ai
00
0 O Y
In
uX�'•",' �
vv
w_. y
THIS DOCUMENT AND/OR THE DESIGN
CONCEPTS EXPRESSED HEREIN ARE THE
PROPERTY OF KEESEE ASSOCIATES AND
ALL RIGHTS OF OWNERSHIP, INCLUDING
COPYRIGHT OF INTELLECTUAL PROPERTY,
ARE RESERVED THE REPRODUCTIONS,
COPYING, OR USE OF THIS DOCUMENT
AND/OR THE DESIGN CONCEPT WITHOUT
THE WRITTEN CONSENT OF KEESEE
ASSOCIATES IS STRICTLY PROHIBITED AND
PROTECTED BY UNITED STATES AND
INTERNATIONAL LAW.
' f
`r�r)02'
° a, w m m
.sn
orer
rr�r f 'SOON A`- �% %1 �'fl"11111 1111"$
�
E
G
SHEET INFORMATION
DATE: 06126/2017
DRAWN BY: DRN
PROJECT NO: 16-2235
REMEWiED BY: JBN
VFJ Plan Revisions Date:
Sheet Name -T
PLUMBING
DETAILS
Sheet No,