Loading...
HomeMy WebLinkAbout2422 Waxwing Way #17-2880; NSFHCOUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 17100007 DATE: October 03, 2017' U1 BUILDING APPLSCATION #: 17-10400717 BUILDING PERMIT NUMBER: 17-10000717 UNIT ADDRESS: WAXWING WAY 242.2 X1.7--20--31-502 0000--1440 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LO` - OWNER NAME: ADDRESS: APPLICANT NAME: PARK SQUARE ENTERPRISE LLC ADDRESS: 5200 VINELAND ROAD SUITE 200 ORLANDO FL 32811 LAND USE: WYNDHAM.PRESERVE TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 2422 WAXWING WAY./ LOT 144 WYNDHAM PRESERVE ----------------T-------T-mm -- ^--UNITTOTAL TT-rm- - FEEBENEFIT RATEUNITCALCDUE TYPE DIST SCHED RATE UNITS TYPE ----------------------------------------------------------------------------------- ROADS-ARTERIALS CO -WIDE ORD Single,Faadlyf Housing 705.00 1.000 dwl unit 705.00 ROADS'-COLLFCTQRS N/A Single Family Hou Ing OU 1.000 dwl, unit .QO FIRE RESCUE N)A 00 LIBRARY CO -WIDE ORD Single Family Housinc{ 54..00 1:000 dwl unit 54.00 SCHOOLS CO -WIDE ORD Single Family Hoping 5,000.00 1.000 dwl unit 5,000.00 PARKS .UO LAW ENFORCE N/A 00 DRAINAGE N/A .00 ANOU.N R DUE 5,759,00 STATEMENT -SIGNATURE: RECEIVED BY: ( PLEASE PRINT NAME) DA'Z'E : L ob7 -c- NOTE TO RECEIVING SIGNATORY/APPLICANT: FAILURE TO NOTIFY OWNER AND ENSURE TIMELY PAYMENT MAY RESULT IN YOUR LIABILITY FOR THE FEE. k** DISTRIBUTION: 1 -BLDG DEPT 3-APFLTCANT 2-FINArICE 4-LA1rLJ MANAGEMENT **NOTE** PERSONS ARE ADVISED .THAT' T41S IS A STATEMENT OF FEES.DUE UNDER THE SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. PERSONS .ARE ALSO ADVISED THAT AMY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF .ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED. BY FILING A WRITTEN REQUEST WITHIN 4.5 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE, BUT NOT LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE PLAN IMPLEMENTA'T'ION OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. 9\. PAYMENT SHOULD BE; MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT, SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT. ***THIS STATEMENT IS NO LONGER. VALID IF A BUILDING PERMIT IS NOT*** ISSUED WITHIN 60 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE * DETAIL OF CAL(MATION AVAIIJWLF UPON REQUEST- CAI:J� 407-665-7356. ,Revision LX Response to Comments ❑ Permit # 17-2880 4"�"Subc�iittal Date City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov 2/5/18 Project Address: 2422 Waxwing Way (Wyndham Preserve lot 144) contact: Michelle Parkison Ph: 407-529-3135 Fax: % ! f- V -P C Email: mparkison a&parksquarehomes.com --Q6A �)�e Trades encompassed in revision: ❑ Building ❑ Plumbing ❑ Electrical ❑ Mechanical ❑ Lille Safety ❑ Waste Water Department ❑ Utilities ❑ Waste Water ❑ Planning ❑ Engineering ❑ Fire Prevention ❑ Building General description of revision: Revised Stair Framing ROU'T'ING INFORMA'T'ION Approvals Fkf37 GENERAL NOTES FOUNDATIONS SOIL UNDER SLABS AND UNDER FOOTINGS TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM- 1557 (MODIFIED PROCTOR) MINIMUM BEARING CAPACITY 2000 PSF TERMITE TREATMENT THE SOIL UNDER THIS STRUCTURE SHALL BE TREATED FOR THE PREVENTION OF SUBTERRANEAN TERMITES, OR A PERIMITER TREATMENT (BORACARE) MAY BE USED, IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. CAST IN PLACE CONCRETE 1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2500 PSI, A SLUMP OF 4" PLUS OR MINUS 1", AND HAVE 2 TO 4% AIR ENTRAINMENT, AND A MAXIMUM WATER/CEMENT RATIO OF 0.58. 2. ALL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 GRADE 60 3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 FOR 6x6xW1.4xW1.4 WWF SHALL BE LAPPED AT LEAST 6" & CONTAIN AT LEAST ONE CROSS WIRE WITHIN THE 6".FIBERMIX OF EQUAL SPECIFICATIONS MAY BE USED IN LIEU OF WWF. 4. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH "THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" ACI 318 LATEST EDITION, AND "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS," AGI 301. 5. HORIZONTAL FOOTING BARS SHALL BE BENT MIN. 12 BAR DIAMETERS (EXCLUDING BEND) AROUND CORNERS OR CORNER BARS WITH MIN. 30" LAP EXCLUDING BEND AT EACH END SHALL BE PROVIDED. 6. MINIMUM LAP SPLICES ON ALL REINFORCING BARS SHALL BE 48 BAR DIAMETERS. 7. SLAB ON GRADE, REINFORCEMENT SHALL BE SUPPORTED IN PLACE FROM THE CENTER TO UPPER 1/3 OF THE SLAB, BOLTS AND THREADED RODS 1. ALL BOLTS & THREADED RODS TO BE ASTM A307 OR BETTER (U.N.O.) 2. STEEL BOLTS LESS THAN ONE -HALF-INCH (12.7 mm) IN DIAMETER USED AS FASTENERS FOR PRESSURE PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. 3. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS SHALL BE PERMITTED TO BE OF MECHANICALLY DEPOSITED ZINC -COATED STEEL WITH COATING WEIGHTS IN ACCORDANCE WITH ASTM B 695, CLASS 55, MINIMUM. MASONRY WALL CONSTRUCTION 1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, W/ A MINIMUM NET COMPRESSIVE STRENGTH OF 2000 PSI (fm = 1900 PSI) 2. MORTAR SHALL BE TYPE M OR S, CONFORMING TO ASTM C270 3. HEAD MORTAR JOINTS AT PRECAST WINDOW SILLS TO BE NO MORE THAN 1". 4. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. 5. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS WITH CELLS FILLED WITH COARSE GROUT AND GRADE 60 STEEL. REINFORCEMENT SHALL BE PLACED IN CENTER OF MASONRY CELL W/ MIN 1/2" CLEARANCE TO INSIDE FACE. 6. VERTICAL REINFORCEMENT SHALL BE HELD IN CENTER OF THE MASONRY/ BLOCK WALL AT THE TOP & BOTTOM & MAXIMUM 8'-0" U.N.O. VERITCALLY. TIES TO THE FOOTING & LINTEL STEEL IS ADEQUATE @ TOP & BOTTOM OF WALL; REBAR POSITIONERS IN MIDDLE OF WALL 7. REINFORCING STEEL SHALL BE LAPPED MIN. 25" U.N.O. 8. HOOKS AT THE TOP & BOTTOM OF VERTICAL REINFORCING BARS TO BOND COURSE AND FOOTING TO BE NO LESS THAN 12 BAR DIAMETERS EXCLUDING BEND 9. EXPANSION TYPE ANCHORS ARE NOT TO BE USED IN BOND COURSE. EMBEDDED ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. 10. MASONRY ROUGH OPENING TOLERANCES - 1/4" TO + 1/2" 11. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC SCREEN, METAL LATH STRIP OR CAVITY CAPS MAY BE USED TO PREVENT THE FLOW OF GROUT INTO CELLS BELOW. THE USE OF FELT PAPER AS A STOP IS PROHIBITED. 12. TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR 13. DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS AND NO CONCENTRATED LOADS FOR (7) DAYS. PER CODE ACI 318, LATEST EDITION. 14. DURING CONCRETE POURS, GC TO ADEQUATELY VIBRATE THE FILLED CELL W/ EITHER RODDING OR PENCIL VIBRATOR TO ENSURE PROPER CONCRETE CONSOLIDATION. WOOD CONSTRUCTION 1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION", LATEST EDITION.(NDS) 2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS. SHEAR WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS. (I.E. BLOCKING OR GABLE END BRACING), SHALL BE SPRUCE- PINE -FIR OR EQUIVALENT. NO. 2 GRADE SHALL BE USED REGARDLESS OF SPECIES U.N.O. ON FRAMING PLANS OR DETAILS. END -JOINTED LUMBER IS NOT PERMITTED TO BE USED IN ANY LOAD BEARING (GRAVITY OR WIND) CONDITIONS. E.O.R. TO REVIEW IF INSTALLED. 3. FIELD -CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE -TREATED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. 4. THE PORTIONS OF GLUED -LAMINATED TIMBERS THAT FORM THE STRUCTURAL SUPPORTS OF A BUILDING OR OTHER STRUCTURE AND ARE EXPOSED TO WEATHER AND NOT PROPERLY PROTECTED BY A ROOF, EAVE OR SIMILAR COVERING SHALL BE PRESSURE TREATED WITH PRESERVATIVE, OR BE MANUFACTURED FROM NATURALLY DURABLE OR PRESERVATIVE -TREATED WOOD. 5. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY (MOISTURE CONTENT 19% OR LESS), U.N.O. ALL WATERPROOFING AND FIRE SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHERS. 6. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT HAVE HOLES IN THE CENTER OF THE STUD UP TO 1" DIA. SHALL HAVE STUD PROTECTION SHEILDS. ALL HOLES OVER 1" IN DIA FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH SIMPSON HSS2 STUD SHOES, TYP U.N.O. 7. MANY OF THE PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE BUILDER'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE. ACQ-C, ACQ-D, CBA -A OR CA -B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOR SODIUM BORATE (SEX) DOES NOT. 8. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH, CONCRETE OR MASONRY IS TO BE PRESSURE TREATED. 9. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE OR MASONRY, SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 10. SEE PLAN FOR BUILT UP STUD COLUMN AND BEAM NAILING PATTERNS I L ENGINEERED LUMBER ALL ENGINEERED LUMBER IS TO HAVE THE MINIMUM DESIGN VALUES AS FOLLOWS: COLUMNS BEAMS STUD E = 1,700,000 Ib/int U.N.O. E = 2,000,000 Ib/int U.N.O. E = 1,500,000 Ib/int U.N.O Fb =2650 Fb =3000 Fb =2200 Ft = 1650 Ft = 1700 Ft = 1500 Fc 11= 3000 Fc 11= 3000 Fc 11= 2100 Fc 1= 450 Fc j = 900 Fc 1= 450 Fv =285 Fv =285 Fv = 150 WOOD BEARING SURFACES ARE TO BE SYP#2 OR BETTER END GRAIN CONDITION U.N.O. Q rY • �.., } O (- VALUE DENOTES SUCTION CEILING CONSTRUCTION 4O 1. USE 1/2" CEILING OR SAG RESISTANT BOARD FOR 24" O.C. FRAMING U.N.O. 2. 5/8" TYPE "X" GYPSUM BOARD SHALL BE USED ON CEILING IN GARAGE WHEN LIVING SPACE IS ABOVE THE GARAGE. MEANS AND METHODS CONSTRUCTION MEANS & METHODS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE STRUCTURE IS UNSTABLE UNTIL ALL LOAD BEARING WALLS ARE ERECTED & TRUSS / FRAME MEMBERS ARE CONNECTED PROPERLY PER APPROVED FRAMING PLANS / DETAILS ALONG W/ CONNECTOR & COMPONENT MANUFACTURERS' SPECIFICATIONS. UNTIL SUCH TIME, TEMPORARY BRACING & SHORING OF WALLS AND FRAME MEMBERS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. UNDER STAIR PROTECTION 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2 -INCH (12.7MM) GYPSUM BOARD. METAL COATINGS FOR USE WITH PRESSURE TREATED WOOD IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT ALL METAL CONNECTORS, METAL FASTENERS, ANCHORS, AND NAILS ARE THE APPROPRIATE MATERIAL AND/OR HAVE THE APPROPRIATE COATING FOR USE WITH THE DIFFERENT TYPES OF PRESSURE TREATED WOODS, AS PER THE FOLLOWING GUIDELINES. 1. WOOD TREATED WITH DOT SODIUM BORATE(SBX): CONNECTORS SHALL BEA MINIMUM G50 ZINC COATING 2. WOOD TREATED WITH ACQ-C OR ACQ-D (CARBONATE) OR OTHER BORATE (NON -DOT) TREATMENTS: CONNECTORS SHALL BE A MINIMUM 6185 ZINC COATING. 3. FOR ALL OTHER COMBINATIONS FOLLOW THE RECOMMENDATIONS OF THE PRESERVATIVE WOOD TREATER. 4. STAINLESS STEEL CONNECTORS AND FASTENERS MAYBE USED WITH ALL TYPES OF PRESSURE TREATED WOOD. PREFABRICATED WOOD TRUSSES 1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH HURRICANE CLIPS OR ANCHORS.UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT OR LATERAL FORCES. INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE COORDINATE WITH THE TRUSS ENGINEER FOR THE LOCATION OF THESE WALLS AND STRUCTURAL PLANS FOR MORE INFO. 2. TRUSSES SHALL BE DESIGNED BY MWFRS METHODOLOGY FOR LONG SPAN TRUSSES TO DETERMINE UPLIFT AND REACTION VALUES. MEMBER AND PLATE DESIGN TO BE CALCULATED BY COMPONENTS AND CLADDING METHOD UNLESS SPECIFIED OTHERWISE BY TRUSS ENGINEER OF RECORD 3. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI TPI 1, 4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS REQUIRED BY TRUSS MANUFACTURER UNLESS NOTED ON PLANS " 5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE NOT SHOWN, BUT SHALL BE DESIGNED BY TRUSS MANUFACTURER IN ACCORDANCE WITH THE DESIGN LOADS. TRUSS DESIGN LOADS: TOP CHORD: Lr =16 PSF DL = 7 PSF (SHINGLE TYPE ROOF COVER) DL = 15 PSF (LIGHT WEIGHT CLAY TILE ROOF COVER) DL = 14 PSF (TRUSS OVERBUILD) BOTTOM CHORD: DL = 5 PSF MINIMUM FLOOR DESIGN LIVE LOADS: A) FLOORS = 40 PSF B) BALCONIES= 60 PSF / 100 PSF (IF BALCONY > 100 SQ FT) C) DECKS = 40 PSF D) STAIRS = 40 PSF E) BONUS ROOM/GAME ROOMS = 60 PSF U.N.O. MINIMUM FLOOR DESIGN DEAD LOADS: A) FLOORS = 15 PSF B)BALCONIES = 15 PSF GENERAL LOADING: ATTIC WITHOUT STORAGE = 10 PSF ATTIC WITH LIMITED STORAGE = 20 PSF GUARDRAILS / HANDRAILS = 200 LB POINT LOAD / 50 PSF GUARDRAILS IN -FILL COMPONENTS = 50 PSF GENERAL TRUSS BRACING & BLOCKING REQUIREMENTS -ADDIT'L BRACING & BLOCKING PER BCSI-1 & TRUSS MANUFACTURER'S DWGS -G.C. TO PROVIDE MIN 2x SYP #2 BLOCKING BETWEEN TRUSSES TO COMPLY W/ APA RECOMMENDATIONS FOR MIN. 7/16" OSB SHEATHING -MIN 2x SYP #2 BLOCKING REQ'D ALONGSIDE TRUSS TOP CHORD @ ROOF HIP/RIDGE TO PREVENT SHEATHING SPAN FROM EXCEEDING 2FT (NOT REQ'D IF SHEATHING SPAN IS LESS THAN 2FT). BLOCKING TO TRUSS TOP CHORD w/ (2) 12d NAILS @ 12" O.C. MAX & 4" FROM EA. END. NOTE: PLYWOOD EDGES @ HIP CORNERS REQUIRE MIN 2x4 SYP #2 BLOCKING w/ (3) 12d TOENAILS EACH END. -TRUSS "X" BRACING: MIN 2x4 SYP #2 AT ANGLE APPROX. 45° FROM VERT. TO EA. TRUSS MEMBER w/ (3) 12d NAILS. SPACE "X" BRACING ALONG TRUSS SPAN @ 10'-0" MAX AND EQUALLY SPACED FROM END OF TRUSS. "X" BRACING TO START 20'-0" MAX FROM #1 HIP GIRDER AND / OR (4) BAYS AFTER GABLE END BRACING. SEE BCSI-83 SECTIONS 1, 2 AND 3 FOR ADDITIONAL ROOF PLANE PERMANENT BRACING REQUIREMENTS. -PERMANENT 2x4 SPF #2 (MIN.) CONT. LATERAL TRUSS BOTTOM CHORD BRACING PERPENDICULAR TO TRUSS SPAN AT 154" O.C. MAX W/IN TRUSS SPAN OR PER TRUSS DESIGN DRAWINGS. ATTACH W/ (2) 16d NAILS AT EACH TRUSS. OVERLAP BRACING AT LEAST ONE TRUSS SPACE (24") PLUS 6" MIN PAST BOTTOM CHORD. -INSTALL PERMANENT 2x CONTINUOUS LATERAL BRACE (CLB) ACROSS TRUSS WEBS AS INDICATED ON TRUSS SHOP DRAWINGS & BCS1-133. ("T" BRACING MAY BE USED I,L.O. PEMANENT CLB IF IT EXTENDS MIN. 90% OF THE TRUSS WEB (SEE WEB REINFORCEMENT TABLE WITHIN BCSI-133). -AT RAISED HEEL TRUSSES, 2x4 SYP #2 (MIN.) AT TOP AND BOTTOM OF HEEL W/ (2) 12d TOENAILS REQ'D, EXT. SHEATHING MUST BE ATTACHED TO RAISED HEEL TRUSS AND INDICATED BLOCKING. ALTERNATE IF HEEL HEIGHT IS LESS THAN 12" TALL: 2x4 SYP #2 BEHIND THE TRUSS VERT. RUNNING FROM TOP TO BOTTOM ACROSS MAX 4 TRUSSES, THEN BOTTOM TO TOP W/ (2) 12d NAILS AT EACH TRUSS MEMBER (DIAGONAL BRACING) DIAGONAL BRACING REQUIRED AT CLB PER BCSI-B3. 6. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS, WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. 1. OMITTED REBAR DRILL A 3/4" O HOLE MIN. 6" DEEP AT LOCATION OF OMITTED REBAR, AND INSTALL #5 BAR INTO EPDXY FILLED HOLE, EPDXY TO BE SIMPSON STRONG TIE EPDXY OR EQ. FOLLOW MANU'S INSTRUCTIONS. ASSURE ALL DUST AND DEBRIS FROM DRILLING ARE REMOVED FROM HOLE w/ COMPRESSED AIR PRIOR TO APPLYING EPDXY. ALLOW EPDXY TO CURE TO MANU'S SPECIFICATIONS, THEN FILL CELL IN NORMAL WAY DURING BONDBEAM POUR. USE 30" MIN. LAP SPLICE. HOOKS AT TOP OF BAR TO BE MIN. 12 BAR DIAMETERS(EXCLUDING BEND). 2. STRAPS/CONNECTOR SUBSTITUTION MAY SUB STRAPS/CONNECTORS w/ STRAPS/CONNECTORS OF EQUAL OR GREATER UPLIFT & LATERAL RESISTANCE VALUES IN FIELD WITHOUT VERIFICATION, PROVIDED ALL MANUFACTURER'S INSTALLATION INSTRUCTIONS ARE FOLLOWED. 3. STAIR CONSTRUCTION 2X12'S MAY BE USED ILO TIMBERSTRANDS FOR STAIR STRINGERS. RIM BOARDS MAY BE USED FOR RISERS & TREADS ILO 2xl2'S (SEE GEN. STAIR DETS FOR ADDIT'L INFO.) 4. METAL STUD SUBSTITUTION WOOD STUDS MAY BE SUBBED w/ METAL STUDS IN NON -LOAD BEARING WALLS 5, OMITTED J -BOLT -1/2" ALL THREAD ROD w/ 2" x 2" SQ. WASHER DRILL & EPDXY w/ SIMPSON SET EPDXY WITH MIN. 7" EMBEDMENT. -1/2"x6" SIMPSON TITEN HD THREADED ANCHORS W/ LBP1/2 WASHER MAY BE USED ILO 1/2" J -BOLT. TAPCON FASTENERS MAY BE USED ILO SIMPSON TITENS 6. MORTAR JOINTS -FOR BED JOINTS 1/2"-1", GROUT FILL CELLS IN BLOCK AFFECTED (NO VERT. REINF. REQ'D) -FOR HEAD JOINTS GREATER THAN 3/4", GROUT FILL CELL IN BLOCKAFFECTED ON EA.SIDE OF JOINT. PROVIDE (1) #5 VERT. REINF. IN EA. CELL CONT. PER PLAN. "EXCEPTION: IF TIE BEAM COURSE AND ADJ. TWO COURSES BELOW, AS WELL AS 1st (2) COURSES FROM FND. HAVE HEAD JOINTS WHICH FALL W/IN THE SPECIFIED TOLERANCES, THE ADDED VERTICAL REINFORCEMENT IS NOT REQ'D TO BE EPDXIED INTO TIE BEAM/FTG -FOR BLOCKS NOT STAGGERED, GROUT FILL CELL EA. SIDE OF JOINT AND PROVIDE (1) #5 VERT. REINF. IN EA. CELL, CONT. PER PLAN. 7. OVERHANGING CMU WALL -FOR CMU OVERHANGING FOUNDATION X1/2", NO FIX IS REQ'D POUR TIEBEAM & VERT. CELLS PER PLAN. -FOR CMU OVERHANGING FOUNDATION FROM +1/2"-1-1/8", GROUT FILL FIRST (3) COURSES IN WALL ALONG AREA AFFECTED & TIE BEAM AND VERTICAL CELLS PER PLAN -FOR CMU OVERHANGING FOUNDATION OVER 1-1/8", CONTACT EOR FOR REPAIRS. STRUCTURAL STEEL 1. MATERIAL SPECS: WIDE FLANGE SECTIONS: ASTM A992, GRADE 36, Fy=36 KSI. TUBE STEEL (HSS): ASTM A500, GRADE B, Fy = 46 KSI. PIPE STEEL: ASTM A53, TYPE E OR S, Fy = 35 KSI. ALL OTHER STRUCTURAL & MISC. STEEL: A36 Fy=36 KSI. 2. STRUCT. CONNECTIONS: ALL STRUCT. BOLTS TO BE A325N U.N.O. ALL A325N BOLTS SHALL BE AT "SNUG -TIGHT" CONDITION AS DEFINED IN THE SPEC. SLIP CRITICAL (SC) BOLTS MUST BE FULLY TENSIONED PER SPEC STRUCT. BOLTS SMALLER THAN 5/8" DIA. TO BE A307 THREADED ROD & CONFORM TO A36 OR A307 ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 SHOP AND FIELD WELDS: E70XX ELECTRODES STEEL REINF.T SHOP DWGS TO BE PROVIDED TO EOR BEFORE FABRICATION FOR REVIEW AND APPROVAL. WELDED CONNECTIONS: ELECTRODES - E70XX UNO (LOW HYDROGEN). FILLET WELDS SHALL BE 3/6" UNO. 3. SUBMIT SHOP DWGS INDICATING ALL SHOP AND ERECTION DETAILS INC. PROFILES, SIZES, SPACING, & LOCATIONS OF STRUCTURAL MEMBERS, CONNECTION ATTACHMENTS, FASTENERS, LOAD, AND TOLERANCES. 4. STRUCTURAL STEEL SHALL RECEIVE SHOP COAT OF PRIMER (COLOR AS DIRECTED BY ARCHITECT) EXCEPT FOR AREAS WHICH WILL RECEIVE SPRAY -ON FIRE PROTECTION. 5. A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND SPECS (IF PROVIDED). SUBMIT REPORTS TO ARCHITECT AND ENGINEER. DESIGN PRESSURES WIND DESIGN LOAD INFORMATION WIND SPEED (ULTIMATE) 140 mph WIND SPEED (ALLOWABLE) 108 mph WIND EXPOSURE B RISK CATEGORY 11 BUILDING TYPE V B ENCLOSURE CLASSIFICATION ENCLOSED INTERNAL PRESSURE COEFFICIENT +/-0.18 ° WIND PRESSURE & SUCTION EFFECTIVE (PSF) WIND N VALUE DENOTES PRESSURE AREA (SQ FT) LLJ Q rY • �.., } O (- VALUE DENOTES SUCTION AREA 4O O S113 (+) 21.2 21.2 10 (-) 22.9 (-) 28.3 O U" (+) 20.2 (+) 20.2 20 (-) 22.0 (-) 26.4 (+) 19.0 (+) 19.0 50 (-) 20.8 (-) 23.9 W (+) 18.0 (+) 18.0 100 (-) 19.8 - 22.0 GARAGE DOORS 9'-0" x 7'-0" 16-0" x T-0" (+) 18.4 (+)17.7- S6 1(-) 20.9 (-) 19.7 WIND PRESSURE/ SUCTION DIAGRAM 5 5 4 4 al 5 5 4$1,A, STANDARD DESIGN PRESSURE NOTES 1. ASCE 7-10 WALL DESIGN ALLOWABLE COMPONENTS AND CLADDING WIND PRESSURES AND SUCTIONS PER FLORIDA BUILDING CODE 5th EDITION (2014). WIND SPEED IS BASED ON LINEAR INTERPOLATION FOR THIS SITE. 2. MEAN ROOF HEIGHT FOR A TYPICAL SINGLE STORY HOME IS 15FT, 2 STORY HOME IS 30FT 3. MULTIPLY THE ABOVE PRESSURES BY 1.67 TO GET ULTIMATE WIND PRESSURES. 4. "a" = END ZONE IS ONLY W/IN 5'-0" OF ALL EXTERIOR BUILDING CORNERS. 5. INDICATED PRESSURES CAN BE INTERPOLATED FOR OTHER DOOR SIZES, OTHERWISE USE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREAS. 6. DESIGNATED AREAS WHERE THE ULTIMATE WIND SPEED IS 140 MPH OR GREATER IS CONSIDERED TO BE IN THE WIND -BOURNE DEBRIS AREA. OPENING PROTECTION REQUIRED. REFER TO SECTION R301.2.1.2 OF THE RESIDENTIAL CODE FOR SPECIFICATION REQUIREMENTS OF THE USE OF WOOD STRUCTURAL PANELS. REFER TO TABLE R301.2.1.2 FOR ATTACHMENT SPECIFICATIONS INDEX OF DRAWINGS • 14,I,1r W (3) m 0 �il� �p� ��� DDDbC Dp iDpD' SHEET SHEET TITLE ° c� _ w W SC STRUCTURAL NOTES _ LLJ Q rY • �.., } O u.. jtrji' O S113 FOUNDATION PLAN z S2E DOWEL PLACEMENT PLAN O O U" "•' z S3 FOUNDATION DETAILS 0 a- - O S413 LINTEL PLAN cr_ W W I-- S513 FIRST FLOOR FRAMING PLAN ° ❑ 1 1 Q CL J- S6 NOTES & CONNECTOR LEGEND L S713 ROOF FRAMING PLAN W W v1ti�� SD1 GENERAL DETAILS � __- O SD2 GENERAL DETAILS C, D SD3 GENERAL DETAILS �W SD4 GENERAL DETAILS SD5 2e STORY DETAILS S D6 2 -,STORY DETAILS R ST1 GENERAL STAIR DETAILS W a W U 0 U) LL O z O Q U O _ F- 2 W Q 0 W O U U z 0 W cn O Q z MASTER UPDATES 0 -� z NUMBER DATE DESCRIPTION INTIALS w _ _ F-- 1 2/17/2017 CREATED ELEV A, B, C, & OPTIONAL BEDROOM#5 _ _ DP Z z Q 2 4/10/2016 QC CLEANUP - ADDED MISSING CALL OUT TO FRAMING PLAN DP RECORD COPY COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. SAS ORO � PAR� W I- co ^ti 1 O o (D Z O W z O z w O CL U n LL. U) CL W p U�l ri, �<k S MI W O • 14,I,1r W (3) m r0/ �il� �p� ��� DDDbC Dp iDpD' '�Z W O p o y �z c� Q U P0 U j W cry -j Uj LLJ Q rY • �.., } O > jtrji' W W Uj S MI W O • O P, r0/ Z� o O H c� P0 LLJ WLji > �- W W Uj C-) ® O U" "•' z z Z Uj CL o O W A' U ❑ 1 1 ODi CL J- C4 L v1ti�� 0 0 Oy 0 O U Z m M J i-- W LLIW o a r - (j) U �- o LU _j 0) r 0 OWcYi E Z LL 0)o O r Q ZUOF ��a`o 5 �wz; A CJ 1 2 � �I y F06 V J -! J -1 -1 < - SCJ 1 ® 1 ATTACH BEAM TO CMU �� cn w Ci `�CJ5 IE w c�ii CJ3 CJ5 r D USING HUC410 W/ (10) 10d A5 B2x12 TO SUPPORT A4 F06 D STAIR LANDING A3 A2 FRAMING SEE DETAIL ST01/ST1 FOR — —__=A Al l Al ADDITIONAL LANDING Al = Al �O Al Al NOTE: COLUMN _ I X TO SUPPORT B — _ A LANDING BEAM ONLY 19 5 V FT1 F/ Al � ATTACH BEAM TO CMU B2x8, FIELD VERIFY BOTTOM OF BEAM FOR STAIR CLEARANCE 2x8 #2 SYP JOISTS AT 16" —� O.C. JOIST SHOULD BUCKET INTO B2x8 W/ A35 1 CLIP AND BEAR OVER FLOOR SYSTEM. CONTRACTOR TO PROVIDE 2x KNEEWALL BELOW W/ STUDS AT 16" O.C. AS REQ'D B2x10 TOP @ 11'-4" L � ilii F4 FT4i F4 D E2 D02 SD F1 F17 D 1 CJ4 CJ3 , C 11� F1 D( 01 e 1010 2 al --- 0j I I N N N N N) DC SD � 1 B1N1 BW1 , 18 B L ------- 2x4 SYP #2 BLOCKING @ 16" O.C. ATTACH EACH END TO TRUSSES F1 W/ (3) 12d TOE -NAILS. ATTACH - BLOCKING TO WALL BELOW W/ SIMPSON DTC CLIPF1 JIQ F1 FT2 D -4 IIS D1 D2 D3 CJ5 \� CJ3 C w 1 SD 1 2 2 1 I Uj co WALL LEGEND Q CV ch CD C f� ❑ o o . = 9'-4" T.O.M. = INTERIOR/EXTERIOR O BEARING WALL (OR LINTEL E' = 11'-4" T.O.M. IF REFERENCED ON SHEET W S4). VERIFY HEIGHT W/ = KNEE WALL TOP ARCHITECTURAL PLANS @ 11'-4" U.N.O. O z 'O V/ O tY Q.. W W z = o F— U) O z Q O o w U ¢ U_ a U LLI 0 ❑ Q c~n z L�LI C� w� E-- ��a y✓d G) oo o� ! G�+W Z_ Q J LLJ O�JPIR�a78d000 O� lL ®� m., O LL W U Q z o ❑ Q U O,/LJ c� Q W (D LLr- �. o Z0 2 O O -� LLI Q) WG�� U =Lr) �W❑ I-- O U W O Ott Q❑ 0M `ter U ❑ OwcN E W 0 zQF- ❑�c�o O� s_j z ix Q o z Q O < O�QwZo O U�ELL Oz OQ�Ucn< ❑ z0wNQ W L. pLU U LJ W LL U) OO W rn U) ® ►6' UQ o �® W W > 11 0 W W X ®0 �Z � Q W Q - z W F_ LU 1J-1 (� cn O W 00 Z 0..N BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: --� -DESIGN: --- STRUCT: JV SANFORD ---- _...__ QC CHECK: MRB FPAR�� JOB No. PSQ-2171526 # 2 8 p SC -- -__--- ALE: �AS INDICATED _-- FIRST FLOOR FRAMING PLAN DATE: 08/28/2017 NOTE: SEE PAGE S6 FOR NOTES AND CONNECTOR LEGEND 1/4"=11-011 COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. 2 ATTACH BEAM TO CMU USING HUC410 W/ (10) 10d B2x12 TO SUPPORT NAILS & (18) 1/4"x2-3/4" STAIR LANDING TAPCONS A FRAMING SEE DETAIL ST01/ST1 FOR — —__=A N ADDITIONAL LANDING ------ ----- = FRAMING INFORMATION F/ ATTACH BEAM TO CMU A USING HUC410 W/ (10) 10d 47 NAILS & (18) 1/4"x2-3/4" \ ____--- TAPCONS "7--- B2x12 TO SUPPORT -- STAIR LANDING FRAMING B2x8, FIELD VERIFY BOTTOM OF BEAM FOR STAIR CLEARANCE 2x8 #2 SYP JOISTS AT 16" —� O.C. JOIST SHOULD BUCKET INTO B2x8 W/ A35 1 CLIP AND BEAR OVER FLOOR SYSTEM. CONTRACTOR TO PROVIDE 2x KNEEWALL BELOW W/ STUDS AT 16" O.C. AS REQ'D B2x10 TOP @ 11'-4" L � ilii F4 FT4i F4 D E2 D02 SD F1 F17 D 1 CJ4 CJ3 , C 11� F1 D( 01 e 1010 2 al --- 0j I I N N N N N) DC SD � 1 B1N1 BW1 , 18 B L ------- 2x4 SYP #2 BLOCKING @ 16" O.C. ATTACH EACH END TO TRUSSES F1 W/ (3) 12d TOE -NAILS. ATTACH - BLOCKING TO WALL BELOW W/ SIMPSON DTC CLIPF1 JIQ F1 FT2 D -4 IIS D1 D2 D3 CJ5 \� CJ3 C w 1 SD 1 2 2 1 I Uj co WALL LEGEND Q CV ch CD C f� ❑ o o . = 9'-4" T.O.M. = INTERIOR/EXTERIOR O BEARING WALL (OR LINTEL E' = 11'-4" T.O.M. IF REFERENCED ON SHEET W S4). VERIFY HEIGHT W/ = KNEE WALL TOP ARCHITECTURAL PLANS @ 11'-4" U.N.O. O z 'O V/ O tY Q.. W W z = o F— U) O z Q O o w U ¢ U_ a U LLI 0 ❑ Q c~n z L�LI C� w� E-- ��a y✓d G) oo o� ! G�+W Z_ Q J LLJ O�JPIR�a78d000 O� lL ®� m., O LL W U Q z o ❑ Q U O,/LJ c� Q W (D LLr- �. o Z0 2 O O -� LLI Q) WG�� U =Lr) �W❑ I-- O U W O Ott Q❑ 0M `ter U ❑ OwcN E W 0 zQF- ❑�c�o O� s_j z ix Q o z Q O < O�QwZo O U�ELL Oz OQ�Ucn< ❑ z0wNQ W L. pLU U LJ W LL U) OO W rn U) ® ►6' UQ o �® W W > 11 0 W W X ®0 �Z � Q W Q - z W F_ LU 1J-1 (� cn O W 00 Z 0..N BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: --� -DESIGN: --- STRUCT: JV SANFORD ---- _...__ QC CHECK: MRB FPAR�� JOB No. PSQ-2171526 # 2 8 p SC -- -__--- ALE: �AS INDICATED _-- FIRST FLOOR FRAMING PLAN DATE: 08/28/2017 NOTE: SEE PAGE S6 FOR NOTES AND CONNECTOR LEGEND 1/4"=11-011 COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. Revision Response to Comments ❑ FEB 14 2018 q BY: _' City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Permit # 17-2880 Submittal Date 2/5/18 Project Address: 2422 Waxwing Way (Wyndham Preserve lot 144) contact: Michelle Parkison Ott., Pli: 407-529-3135 Fax: Entail: mparkison&parksquarehomes.com Trades encompassed in revision: ❑ Building ❑ Plumbing ❑ Electrical ❑ Mechanical ❑ Lire Safety ❑ Waste Water General description of revision: Added rer)air detail for clear story at stair area ROUTING INFORMATION Approvals Department ❑ Utilities ❑ Waste Water ❑ Planning ❑ Engineering ❑ fire Prevention ❑ Building General description of revision: Added rer)air detail for clear story at stair area ROUTING INFORMATION Approvals 1. OMITTED REBAR DRILL A 3/4" 0 HOLE MIN. 6" DEEP AT LOCATION OF OMITTED REBAR, AND INSTALL #5 BAR INTO EPDXY FILLED HOLE. EPDXY TO BE SIMPSON STRONG TIE EPDXY OR EQ. FOLLOW MANU'S INSTRUCTIONS. ASSURE ALL DUST AND DEBRIS FROM DRILLING ARE REMOVED FROM HOLE w/ COMPRESSED AIR PRIOR TO APPLYING EPDXY. ALLOW EPDXY TO CURE TO MANU'S SPECIFICATIONS, THEN FILL CELL IN NORMAL WAY DURING BONDBEAM POUR. USE 30" MIN. LAP SPLICE. HOOKS AT TOP OF BAR TO BE MIN. 12 BAR DIAMETERS(EXCLUDING BEND). 2. STRAPS/CONNECTOR SUBSTITUTION MAY SUB STRAPS/CONNECTORS w/ STRAPS/CONNECTORS OF EQUAL OR GREATER UPLIFT & LATERAL RESISTANCE VALUES IN FIELD WITHOUT VERIFICATION, PROVIDED ALL MANUFACTURER'S INSTALLATION INSTRUCTIONS ARE FOLLOWED, 3. STAIR CONSTRUCTION 2X12'S MAY BE USED ILO TIMBERSTRANDS FOR STAIR STRINGERS. RIM BOARDS MAY BE USED FOR RISERS & TREADS ILO 2x12'S (SEE GEN. STAIR DETS FOR ADDIT'L INFO.) 4. METAL STUD SUBSTITUTION WOOD STUDS MAY BE SUBBED w/ METAL STUDS IN NON -LOAD BEARING WALLS 5. OMITTED J -BOLT -1/2" ALL THREAD ROD w/ 2" x 2" SQ. WASHER DRILL & EPDXY w/ SIMPSON SET EPDXY WITH MIN. 7" EMBEDMENT. -1/2"x6" SIMPSON TITEN HD THREADED ANCHORS W/ LBP1/2 WASHER MAY BE USED ILO 1/2" J -BOLT. TAPCON FASTENERS MAY BE USED ILO SIMPSON TITENS 6. MORTAR JOINTS -FOR BED JOINTS 1/2"-1", GROUT FILL CELLS IN BLOCKAFFECTED (NO VERT. REINF. REQ'D) -FOR HEAD JOINTS GREATER THAN 3/4", GROUT FILL CELL IN BLOCKAFFECTED ON EA.SIDE OF JOINT. PROVIDE (1) #5 VERT. REINF. IN EA. CELL CONT. PER PLAN. "EXCEPTION: IF TIE BEAM COURSE AND ADJ. TWO COURSES BELOW, AS WELL AS 1st (2) COURSES FROM FND. HAVE HEAD JOINTS WHICH FALL W/IN THE SPECIFIED TOLERANCES, THE ADDED VERTICAL REINFORCEMENT IS NOT REQ'D TO BE EPDXIED INTO TIE BEAM/FTG -FOR BLOCKS NOT STAGGERED, GROUT FILL CELL EA. SIDE OF JOINT AND PROVIDE (1) #5 VERT. REINF. IN EA. CELL, CONT. PER PLAN. 7. OVERHANGING CMU WALL -FOR CMU OVERHANGING FOUNDATION <1/2", NO FIX IS REQ'D POUR TIEBEAM & VERT. CELLS PER PLAN. -FOR CMU OVERHANGING FOUNDATION FROM +1/2"-1-1/8", GROUT FILL FIRST (3) COURSES IN WALL ALONG AREA AFFECTED & TIE BEAM AND VERTICAL CELLS PER PLAN -FOR CMU OVERHANGING FOUNDATION OVER 1-1/8", CONTACT EOR FOR REPAIRS. STRUCTURAL STEEL 1. MATERIAL SPECS: WIDE FLANGE SECTIONS: ASTM A992, GRADE 36, Fy=36 KSI. TUBE STEEL (HSS): ASTM A500, GRADE B, Fy = 46 KSI. PIPE STEEL: ASTM A53, TYPE E OR S, Fy = 35 KSI. ALL OTHER STRUCTURAL & MISC. STEEL: A36 Fy=36 KSI. 2. STRUCT. CONNECTIONS: ALL STRUCT. BOLTS TO BE A325N U.N.O. ALL A325N BOLTS SHALL BE AT "SNUG -TIGHT" CONDITION AS DEFINED IN THE SPEC. SLIP CRITICAL (SC) BOLTS MUST BE FULLY TENSIONED PER SPEC STRUCT. BOLTS SMALLER THAN 5/8" DIA. TO BE A307 THREADED ROD & CONFORM TO A36 OR A307 ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 SHOP AND FIELD WELDS: E70XX ELECTRODES STEEL REINF.T SHOP DWGS TO BE PROVIDED TO EOR BEFORE FABRICATION FOR REVIEW AND APPROVAL. WELDED CONNECTIONS: ELECTRODES - E70XX UNO (LOW HYDROGEN). FILLET WELDS SHALL BE Y16" UNO. 3. SUBMIT SHOP DWGS INDICATING ALL SHOP AND ERECTION DETAILS INC. PROFILES, SIZES, SPACING, & LOCATIONS OF STRUCTURAL MEMBERS, CONNECTION ATTACHMENTS, FASTENERS, LOAD, AND TOLERANCES. 4. STRUCTURAL STEEL SHALL RECEIVE SHOP COAT OF PRIMER (COLOR AS DIRECTED BY ARCHITECT) EXCEPT FOR AREAS WHICH WILL RECEIVE SPRAY -ON FIRE PROTECTION. 5. A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND SPECS (IF PROVIDED). SUBMIT REPORTS TO ARCHITECT AND ENGINEER. DESIGN PRESSURES ENGINEERED LUMBER GENERAL NOTES ALL ENGINEERED LUMBER IS TO HAVE THE MINIMUM DESIGN WIND EXPOSURE B VALUES AS FOLLOWS: FOUNDATIONS COLUMNS BEAMS STUD SOIL UNDER SLABS AND UNDER FOOTINGS TO BE COMPACTED TO AT LEAST 95% OF E = 1,700,000 Wine U.N.O. E = 2,000,000 Ib/int U.N.0. E = 1,500,000 Ib/int U.N.O. MAX. DRY DENSITY AS DETERMINED BY ASTM- 1557 (MODIFIED PROCTOR) MINIMUM Fb - 2650 Fb = 3000 Fb - 2200 BEARING CAPACITY 2000 PSF TERMITE TREATMENT Ft = 1650 Ft = 1700 Ft = 1500 Fc 11= 3000 Fc 11= 3000 Fc 11= 2100 THE SOIL UNDER THIS STRUCTURE SHALL BE TREATED FOR THE Fc 1= 450 Fc 1= 900 Fc j = 450 PREVENTION OF SUBTERRANEAN TERMITES, OR A PERIMITER TREATMENT Fv = 285 Fv = 285 Fv = 150 (BORACARE) MAY BE USED, IN ACCORDANCE WITH RULES AND LAWS WOOD BEARING SURFACES ARE TO BE SYP#2 OR BETTER END GRAIN ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND (+) 21.2 CONSUMER SERVICES. CONDITION U.N.O. (-) 22.9 CEILING CONSTRUCTION CAST IN PLACE CONCRETE 1. USE 1/2" CEILING OR SAG RESISTANT BOARD FOR 24" O.C. FRAMING U.N.O. (+) 20.2 2. 5/8" TYPE "X" GYPSUM BOARD SHALL BE USED ON CEILING IN GARAGE WHEN 1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF LIVING SPACE IS ABOVE THE GARAGE. 2500 PSI, A SLUMP OF 4" PLUS OR MINUS 1", AND HAVE 2 TO 4% AIR ENTRAINMENT, MEANS AND METHODS AND A MAXIMUM WATER/CEMENT RATIO OF 0.58. 2. ALL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO CONSTRUCTION MEANS & METHODS ARE THE SOLE RESPONSIBILITY OF THE ASTM A-615 GRADE 60 CONTRACTOR. THE STRUCTURE IS UNSTABLE UNTIL ALL LOAD BEARING WALLS ARE 3, WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 FOR 6x6xW1.4xW1.4 ERECTED & TRUSS / FRAME MEMBERS ARE CONNECTED PROPERLY PER APPROVED WWF SHALL BE LAPPED AT LEAST 6" & CONTAIN AT LEAST ONE CROSS WIRE WITHIN FRAMING PLANS /DETAILS ALONG W/ CONNECTOR &COMPONENT MANUFACTURERS' THE 6".FIBERMIX OF EQUAL SPECIFICATIONS MAY BE USED IN LIEU OF WWF. SPECIFICATIONS. UNTIL SUCH TIME, TEMPORARY BRACING & SHORING OF WALLS AND 4. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH "THE BUILDING CODE FRAME MEMBERS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. REQUIREMENTS FOR REINFORCED CONCRETE" ACI 318 LATEST EDITION, AND UNDER STAIR PROTECTION "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS," ACI 301. 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR 5. HORIZONTAL FOOTING BARS SHALL BE BENT MIN. 12 BAR DIAMETERS (EXCLUDING SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2 -INCH BEND) AROUND CORNERS OR CORNER BARS WITH MIN. 30" LAP EXCLUDING BEND (12.7MM) GYPSUM BOARD. AT EACH END SHALL BE PROVIDED. METAL COATINGS FOR USE WITH PRESSURE TREATED WOOD 6. MINIMUM LAP SPLICES ON ALL REINFORCING BARS SHALL BE 48 BAR DIAMETERS. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT ALL METAL CONNECTORS, 7. SLAB ON GRADE, REINFORCEMENT SHALL BE SUPPORTED IN PLACE FROM THE 1. ASCE 7-10 WALL DESIGN ALLOWABLE COMPONENTS AND CENTER TO UPPER 1/3 OF THE SLAB. METAL FASTENERS, ANCHORS, AND NAILS ARE THE APPROPRIATE MATERIAL BOLTS AND THREADED RODS AND/OR HAVE THE APPROPRIATE COATING FOR USE WITH THE DIFFERENT TYPES IS 15FT, 2 STORY HOME IS 30FT OF PRESSURE TREATED WOODS, AS PER THE FOLLOWING GUIDELINES. 1. ALL BOLTS &THREADED RODS TO BE ASTM A307 OR BETTER U.N.O.) ( 1. WOOD TREATED WITH DOT SODIUM BORATE(SBX): CONNECTORS SHALL BE A 2. STEEL BOLTS LESS THAN ONE -HALF-INCH (12.7 mm) IN DIAMETER USED AS MINIMUM G50 ZINC COATING FASTENERS FOR PRESSURE PRESERVATIVE -TREATED WOOD SHALL BE OF 2. WOOD TREATED WITH ACQ-C OR ACQ-D (CARBONATE) OR OTHER BORATE HOT -DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE (NON -DOT) TREATMENTS: CONNECTORS SHALL BE A MINIMUM G185 ZINC COATING. OR COPPER. FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. 3, FOR ALL OTHER COMBINATIONS FOLLOW THE RECOMMENDATIONS OF THE 3. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS SHALL BE PERMITTED TO BE PRESERVATIVE WOOD TREATER. OF MECHANICALLY DEPOSITED ZINC -COATED STEEL WITH COATING WEIGHTS IN 4. STAINLESS STEEL CONNECTORS AND FASTENERS MAYBE USED WITH ALL TYPES ACCORDANCE WITH ASTM B 695, CLASS 55, MINIMUM. OF PRESSURE TREATED WOOD. MASONRY WALL CONSTRUCTION PREFABRICATED WOOD TRUSSES 1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT, GRADE N, TYPE 2, 1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY FASTENED TO THEIR CONFORMING TO ASTM C90, W/ A MINIMUM NET COMPRESSIVE STRENGTH OF 2000 SUPPORTING WALLS OR BEAMS WITH HURRICANE CLIPS OR ANCHORS.UPLIFT PSI (fm = 1900 PSI) CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS ANCHORS AND ANCHOR BOLTS ARE 2. MORTAR SHALL BE TYPE M OR S, CONFORMING TO ASTM C270 ONLY REQUIRED ON MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT OR LATERAL 3. HEAD MORTAR JOINTS AT PRECAST WINDOW SILLS TO BE NO MORE THAN 1". FORCES. INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED TO UPLIFT FORCES. 4. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE THE MEMBERS OF THESE WALLS WOULD NOT NEED TO HAVE CONNECTORS APPLIED. SIZE OF 3/8" AND A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. PLEASE COORDINATE WITH THE TRUSS ENGINEER FOR THE LOCATION OF THESE WALLS 5. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS WITH CELLS AND STRUCTURAL PLANS FOR MORE INFO. FILLED WITH COARSE GROUT AND GRADE 60 STEEL. REINFORCEMENT SHALL BE 2. TRUSSES SHALL BE DESIGNED BY MWFRS METHODOLOGY FOR LONG SPAN TRUSSES TO PLACED IN CENTER OF MASONRY CELL W/ MIN 1/2" CLEARANCE TO INSIDE FACE. DETERMINE UPLIFT AND REACTION VALUES. MEMBER AND PLATE DESIGN TO BE 6. VERTICAL REINFORCEMENT SHALL BE HELD IN CENTER OF THE MASONRY/ BLOCK CALCULATED BY COMPONENTS AND CLADDING METHOD UNLESS SPECIFIED OTHERWISE BY WALL AT THE TOP & BOTTOM & MAXIMUM 8'-0" U.N.O. VERITCALLY. TIES TO THE TRUSS ENGINEER OF RECORD FOOTING & LINTEL STEEL IS ADEQUATE @ TOP & BOTTOM OF WALL; REBAR 3. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE POSITIONERS IN MIDDLE OF WALL LATEST EDITION OF ANSI TPI 1. 7. REINFORCING STEEL SHALL BE LAPPED MIN. 25" U.N.O. 4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS REQUIRED BY TRUSS 8. HOOKS AT THE TOP & BOTTOM OF VERTICAL REINFORCING BARS TO BOND MANUFACTURER UNLESS NOTED ON PLANS COURSE AND FOOTING TO BE NO LESS THAN 12 BAR DIAMETERS EXCLUDING BEND 5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL CONFIGURATION OF 9. EXPANSION TYPE ANCHORS ARE NOT TO BE USED IN BOND COURSE. EMBEDDED TRUSSES ONLY. WEB MEMBERS ARE NOT SHOWN, BUT SHALL BE DESIGNED BY ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. TRUSS MANUFACTURER IN ACCORDANCE WITH THE DESIGN LOADS. 10. MASONRY ROUGH OPENING TOLERANCES - 1/4" TO + 1/2" TRUSS DESIGN LOADS: 11. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC SCREEN, METAL TOP CHORD: Lr = 16 PSF LATH STRIP OR CAVITY CAPS MAY BE USED TO PREVENT THE FLOW OF GROUT INTO DL = 7 PSF (SHINGLE TYPE ROOF COVER) CELLS BELOW. THE USE OF FELT PAPER AS A STOP IS PROHIBITED. DL - 15 PSF (LIGHT WEIGHT CLAY TILE ROOF COVER) 12. TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING DL - 14 PSF (TRUSS OVERBUILD) CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR BOTTOM CHORD: DL = 5 PSF 13. DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS AND NO MINIMUM FLOOR DESIGN LIVE LOADS: CONCENTRATED LOADS FOR (7) DAYS. PER CODE ACI 318, LATEST EDITION. A) FLOORS = 40 PSF B) BALCONIES = 60 PSF / 100 PSF (IF BALCONY > 100 SQ FT) 14. DURING CONCRETE POURS, GC TO ADEQUATELY VIBRATE THE FILLED CELL.W/ C) DECKS = 40 PSF D) STAIRS = 40 PSF EITHER RODDING OR PENCIL VIBRATOR TO ENSURE PROPER CONCRETE E) BONUS ROOM/GAME ROOMS = 60 PSF U.N.O. CONSOLIDATION. MINIMUM FLOOR DESIGN DEAD LOADS: WOOD CONSTRUCTION A) FLOORS = 15 PSF B)BALCONIES = 15 PSF 1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA "NATIONAL DESIGN GENERAL LOADING: SPECIFICATION FOR WOOD CONSTRUCTION", LATEST EDITION.(NDS) ATTIC WITHOUT STORAGE = 10 PSF 2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS. SHEAR WALLS AND MISC. ATTIC WITH LIMITED STORAGE = 20 PSF STRUCTURAL WOOD FRAMING MEMBERS. (I.E. BLOCKING OR GABLE END BRACING), GUARDRAILS / HANDRAILS = 200 LB POINT LOAD / 50 PSF SHALL BE SPRUCE- PINE -FIR OR EQUIVALENT. NO. 2 GRADE SHALL BE USED GUARDRAILS IN -FILL COMPONENTS = 50 PSF REGARDLESS OF SPECIES U.N.O. ON FRAMING PLANS OR DETAILS. END -JOINTED GENERAL TRUSS BRACING & BLOCKING REQUIREMENTS LUMBER IS NOT PERMITTED TO BE USED IN ANY LOAD BEARING (GRAVITY OR WIND) -ADDIT'L BRACING & BLOCKING PER BCSI-1 & TRUSS MANUFACTURER'S DWGS CONDITIONS. E.O.R. TO REVIEW IF INSTALLED. -G.C. TO PROVIDE MIN 2x SYP #2 BLOCKING BETWEEN TRUSSES TO COMPLY W/ APA 3. FIELD -CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE -TREATED WOOD RECOMMENDATIONS FOR MIN. 7/16" OSB SHEATHING SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. -MIN 2x SYP #2 BLOCKING REQ'D ALONGSIDE TRUSS TOP CHORD @ ROOF HIP/RIDGE 4. THE PORTIONS OF GLUED -LAMINATED TIMBERS THAT FORM THE STRUCTURAL TO PREVENT SHEATHING SPAN FROM EXCEEDING 2FT (NOT REQ'D IF SHEATHING SPAN IS SUPPORTS OF A BUILDING OR OTHER STRUCTURE AND ARE EXPOSED TO WEATHER LESS THAN 2FT). BLOCKING TO TRUSS TOP CHORD w/ (2) 12d NAILS @ 12" O.C. MAX & 4" FROM AND NOT PROPERLY PROTECTED BY A ROOF, EAVE OR SIMILAR COVERING SHALL BE EA. END. NOTE: PLYWOOD EDGES @ HIP CORNERS REQUIRE MIN 2x4 SYP #2 BLOCKING w/ (3) PRESSURE TREATED WITH PRESERVATIVE, OR BE MANUFACTURED FROM NATURALLY 12d TOENAILS EACH END. DURABLE OR PRESERVATIVE -TREATED WOOD. -TRUSS "X" BRACING: MIN 2x4 SYP #2 AT ANGLE APPROX. 45° FROM VERT. TO EA. TRUSS 5. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY (MOISTURE MEMBER w/ (3) 12d NAILS. SPACE "X" BRACING ALONG TRUSS SPAN @ 10'-0" MAX AND CONTENT 19% OR LESS), U.N.O. ALL WATERPROOFING AND FIRE SAFETY SYSTEMS ARE EQUALLY SPACED FROM END OF TRUSS. "X" BRACING TO START 20'-0" MAX FROM #1 HIP THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED GIRDER AND / OR (4) BAYS AFTER GABLE END BRACING. SEE BCSI-133 SECTIONS 1, 2 AND 3 BY OTHERS. FOR ADDITIONAL ROOF PLANE PERMANENT BRACING REQUIREMENTS. 6. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT HAVE HOLES IN THE -PERMANENT 2x4 SPF #2 (MIN.) CONT. LATERAL TRUSS BOTTOM CHORD BRACING CENTER OF THE STUD UP TO 1" DIA. SHALL HAVE STUD PROTECTION SHEILDS. ALL PERPENDICULAR TO TRUSS SPAN AT 15'-0" O.C. MAX W/IN TRUSS SPAN OR PER TRUSS HOLES OVER 1" IN DIA FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH SIMPSON DESIGN DRAWINGS. ATTACH W/ (2) 16d NAILS AT EACH TRUSS. OVERLAP BRACING AT LEAST HSS2 STUD SHOES, TYP U.N.O. ONE TRUSS SPACE (24") PLUS 6" MIN PAST BOTTOM CHORD. 7. MANY OF THE PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE -INSTALL PERMANENT 2x CONTINUOUS LATERAL BRACE (CLB) ACROSS TRUSS WEBS TO STEEL. IT IS THE BUILDER'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD AS INDICATED ON TRUSS SHOP DRAWINGS & BCSI-133. ("T" BRACING MAY BE USED I.L.O. TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION, PEMANENT CLB IF IT EXTENDS MIN. 90% OF THE TRUSS WEB (SEE WEB REINFORCEMENT FOR EXAMPLE. ACQ-C, ACQ-D, CBA -A OR CA -B REQUIRE HOT -DIPPED GALVANIZED OR TABLE WITHIN BCSI-133). STAINLESS STEEL FASTENERS. DOR SODIUM BORATE (SBX) DOES NOT. -AT RAISED HEEL TRUSSES, 2x4 SYP #2 (MIN.) AT TOP AND BOTTOM OF HEEL W/ (2) 12d 8. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH, CONCRETE OR MASONRY TOENAILS REQ'D. EXT. SHEATHING MUST BE ATTACHED TO RAISED HEEL TRUSS AND IS TO BE PRESSURE TREATED. INDICATED BLOCKING. ALTERNATE IF HEEL HEIGHT IS LESS THAN 12" TALL: 2x4 SYP #2 9. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE OR BEHIND THE TRUSS VERT. RUNNING FROM TOP TO BOTTOM ACROSS MAX 4 TRUSSES, THEN MASONRY. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT BOTTOM TO TOP W/ (2) 12d NAILS AT EACH TRUSS MEMBER (DIAGONAL BRACING) WOODEN TOP PLATES. DIAGONAL BRACING REQUIRED AT CLB PER BCSI-133. 10. SEE PLAN FOR BUILT UP STUD COLUMN AND BEAM NAILING PATTERNS 6. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS, WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. 1. OMITTED REBAR DRILL A 3/4" 0 HOLE MIN. 6" DEEP AT LOCATION OF OMITTED REBAR, AND INSTALL #5 BAR INTO EPDXY FILLED HOLE. EPDXY TO BE SIMPSON STRONG TIE EPDXY OR EQ. FOLLOW MANU'S INSTRUCTIONS. ASSURE ALL DUST AND DEBRIS FROM DRILLING ARE REMOVED FROM HOLE w/ COMPRESSED AIR PRIOR TO APPLYING EPDXY. ALLOW EPDXY TO CURE TO MANU'S SPECIFICATIONS, THEN FILL CELL IN NORMAL WAY DURING BONDBEAM POUR. USE 30" MIN. LAP SPLICE. HOOKS AT TOP OF BAR TO BE MIN. 12 BAR DIAMETERS(EXCLUDING BEND). 2. STRAPS/CONNECTOR SUBSTITUTION MAY SUB STRAPS/CONNECTORS w/ STRAPS/CONNECTORS OF EQUAL OR GREATER UPLIFT & LATERAL RESISTANCE VALUES IN FIELD WITHOUT VERIFICATION, PROVIDED ALL MANUFACTURER'S INSTALLATION INSTRUCTIONS ARE FOLLOWED, 3. STAIR CONSTRUCTION 2X12'S MAY BE USED ILO TIMBERSTRANDS FOR STAIR STRINGERS. RIM BOARDS MAY BE USED FOR RISERS & TREADS ILO 2x12'S (SEE GEN. STAIR DETS FOR ADDIT'L INFO.) 4. METAL STUD SUBSTITUTION WOOD STUDS MAY BE SUBBED w/ METAL STUDS IN NON -LOAD BEARING WALLS 5. OMITTED J -BOLT -1/2" ALL THREAD ROD w/ 2" x 2" SQ. WASHER DRILL & EPDXY w/ SIMPSON SET EPDXY WITH MIN. 7" EMBEDMENT. -1/2"x6" SIMPSON TITEN HD THREADED ANCHORS W/ LBP1/2 WASHER MAY BE USED ILO 1/2" J -BOLT. TAPCON FASTENERS MAY BE USED ILO SIMPSON TITENS 6. MORTAR JOINTS -FOR BED JOINTS 1/2"-1", GROUT FILL CELLS IN BLOCKAFFECTED (NO VERT. REINF. REQ'D) -FOR HEAD JOINTS GREATER THAN 3/4", GROUT FILL CELL IN BLOCKAFFECTED ON EA.SIDE OF JOINT. PROVIDE (1) #5 VERT. REINF. IN EA. CELL CONT. PER PLAN. "EXCEPTION: IF TIE BEAM COURSE AND ADJ. TWO COURSES BELOW, AS WELL AS 1st (2) COURSES FROM FND. HAVE HEAD JOINTS WHICH FALL W/IN THE SPECIFIED TOLERANCES, THE ADDED VERTICAL REINFORCEMENT IS NOT REQ'D TO BE EPDXIED INTO TIE BEAM/FTG -FOR BLOCKS NOT STAGGERED, GROUT FILL CELL EA. SIDE OF JOINT AND PROVIDE (1) #5 VERT. REINF. IN EA. CELL, CONT. PER PLAN. 7. OVERHANGING CMU WALL -FOR CMU OVERHANGING FOUNDATION <1/2", NO FIX IS REQ'D POUR TIEBEAM & VERT. CELLS PER PLAN. -FOR CMU OVERHANGING FOUNDATION FROM +1/2"-1-1/8", GROUT FILL FIRST (3) COURSES IN WALL ALONG AREA AFFECTED & TIE BEAM AND VERTICAL CELLS PER PLAN -FOR CMU OVERHANGING FOUNDATION OVER 1-1/8", CONTACT EOR FOR REPAIRS. STRUCTURAL STEEL 1. MATERIAL SPECS: WIDE FLANGE SECTIONS: ASTM A992, GRADE 36, Fy=36 KSI. TUBE STEEL (HSS): ASTM A500, GRADE B, Fy = 46 KSI. PIPE STEEL: ASTM A53, TYPE E OR S, Fy = 35 KSI. ALL OTHER STRUCTURAL & MISC. STEEL: A36 Fy=36 KSI. 2. STRUCT. CONNECTIONS: ALL STRUCT. BOLTS TO BE A325N U.N.O. ALL A325N BOLTS SHALL BE AT "SNUG -TIGHT" CONDITION AS DEFINED IN THE SPEC. SLIP CRITICAL (SC) BOLTS MUST BE FULLY TENSIONED PER SPEC STRUCT. BOLTS SMALLER THAN 5/8" DIA. TO BE A307 THREADED ROD & CONFORM TO A36 OR A307 ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 SHOP AND FIELD WELDS: E70XX ELECTRODES STEEL REINF.T SHOP DWGS TO BE PROVIDED TO EOR BEFORE FABRICATION FOR REVIEW AND APPROVAL. WELDED CONNECTIONS: ELECTRODES - E70XX UNO (LOW HYDROGEN). FILLET WELDS SHALL BE Y16" UNO. 3. SUBMIT SHOP DWGS INDICATING ALL SHOP AND ERECTION DETAILS INC. PROFILES, SIZES, SPACING, & LOCATIONS OF STRUCTURAL MEMBERS, CONNECTION ATTACHMENTS, FASTENERS, LOAD, AND TOLERANCES. 4. STRUCTURAL STEEL SHALL RECEIVE SHOP COAT OF PRIMER (COLOR AS DIRECTED BY ARCHITECT) EXCEPT FOR AREAS WHICH WILL RECEIVE SPRAY -ON FIRE PROTECTION. 5. A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND SPECS (IF PROVIDED). SUBMIT REPORTS TO ARCHITECT AND ENGINEER. DESIGN PRESSURES WIND DESIGN LOAD INFORMATION WIND SPEED (ULTIMATE) 140 mph WIND SPEED (ALLOWABLE) 108 mph WIND EXPOSURE B RISK CATEGORY II BUILDING TYPE V B ENCLOSURE CLASSIFICATION ENCLOSED INTERNAL PRESSURE COEFFICIENT +/-0.18 WIND PRESSURE & SUCTION EFFECTIVE (PSF) WIND (�) VALUE DENOTES PRESSURE AREA (SQ FT) (-) VALUE DENOTES SUCTION AREA O 0 (+) 21.2 (+) 21.2 10 (-) 22.9 (-) 28.3 (+) 20.2 (+) 20.2 20 (-) 22.0 (-) 26.4 (+) 19.0 (+) 19.0 50 (-) 20.8 (-) 23.9 100 (+) 18.0 (+) 18.0 (-) 19.8 - 22.0 GARAGE DOORS 9'-0" x T-0" 16'-0" x 7'-0" (+)18.4 + (-) 20.9 (-) 19.7 WIND PRESSURE/ SUCTION DIAGRAM5 5 4 4 5 5 STANDARD DESIGN PRESSURE NOTES 1. ASCE 7-10 WALL DESIGN ALLOWABLE COMPONENTS AND CLADDING WIND PRESSURES AND SUCTIONS PER FLORIDA BUILDING CODE 5th EDITION (2014). WIND SPEED IS BASED ON LINEAR INTERPOLATION FOR THIS SITE, 2, MEAN ROOF HEIGHT FOR A TYPICAL SINGLE STORY HOME IS 15FT, 2 STORY HOME IS 30FT 3. MULTIPLY THE ABOVE PRESSURES BY 1.67 TO GET ULTIMATE WIND PRESSURES. 4. "a" = END ZONE IS ONLY W/IN 5'-0" OF ALL EXTERIOR BUILDING CORNERS. 5. INDICATED PRESSURES CAN BE INTERPOLATED FOR OTHER DOOR SIZES, OTHERWISE USE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREAS. 6. DESIGNATED AREAS WHERE THE ULTIMATE WIND SPEED IS 140 MPH OR GREATER IS CONSIDERED TO BE IN THE WIND -BOURNE DEBRIS AREA. OPENING PROTECTION REQUIRED. REFER TO SECTION R301.2.1.2 OF THE RESIDENTIAL CODE FOR SPECIFICATION REQUIREMENTS OF THE USE OF WOOD STRUCTURAL PANELS. REFER TO TABLE R301.2.1.2 FOR ATTACHMENT SPECIFICATIONS INDEX OF DRAWINGS w 0 0 0 0 SHEET SHEET TITLE ° w w SC STRUCTURAL NOTES w - - - O S113 FOUNDATION PLAN Z S213 DOWEL PLACEMENT PLAN LU S3 FOUNDATION DETAILS 01-1 S413 LINTEL PLAN w z T O Q_� S513 FIRST FLOOR FRAMING PLAN Q o o 0 Cn S6 NOTES & CONNECTOR LEGEND a- a- W S713 ROOF FRAMING PLAN 0 � Cr rr w SD1 GENERAL DETAILS � w O (] cn Q SD2 GENERAL DETAILS > - -- - W N c� SD3 GENERAL DETAILS �0 SD4 GENERAL DETAILS -- - - Q \ `� �i„<G.n9 W SD5 2 -STORY DETAILS a� ®°q. °°° /,tS �r 0 - LL SD6 2 -STORY DETAILS = W a� Cq � I--- _¢ Z P ' aU o ¢ p�`� _�� z eq -, ST1 GENERAL STAIR DETAILS ° - �.t o° ,o�aoTUj Q Otago* A" oca Q �111111111110`��.� LLl "� m U Q Z O i I- w O P. ® I� LL"a O t- o z O z O O O" W W Gq�S� U _ L0 �t - H W 0 G* wp 0 <0 0] J V / z O 0 - W - r- o o Q � rn z_ ❑ -Owm E Q 06 1- 2 rn Q W �QpV�,�'-� m - p zC) Cl e m - 0 cfl J w oL Z w 0 O oz MASTER UPDATES ° " 0 2 (� �<_0�NIJ r, ZpoWNQ W NUMBER DATE DESCRIPTION INTIALS = J �../ 1 2/17/2017 CREATED ELEV A, B, C, & OPTIONAL BEDROOM#5 DP z W-- cn Ili J 2 4/10/2016 QC CLEANUP - ADDED MISSING CALL OUT TO FRAMING PLAN DP TE _ O rnI- W cFn n ® 11-- r, RECORD COPY w <_j W1 W1 W 11 U W W Z 66 Q W IL wJ e I-a0� o 00 U) O W � T_ 0,- UL U BLDG DESIGN: - -- STRUCTURALENG: MCU ICJIO DRAFTING: -DESIGN: --- -STRUCT: JV SANFORU rF'AkS�� #�7-2 COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. QC CHECK: MRB JOB No. PSQ-2171526 SCALE: AS INDICATED DATE: 08/28/2017 ATTACH BEAM TO CMU I F1 USING HUC410 W/ (10) 10d ~ B2x12 TO SUPPORT p 2 NAILS & (18) 1/4"x2-3/4" - STAIR LANDING TAPCONS A FRAMING SEE DETAIL ST01/ST1 FOR = ___ N ADDITIONAL LANDING ------ II = FRAMING INFORMATION ATTACH BEAM TO CMU ®-------- A USING HUC410 W/ (10) 10d ---- ----"--------------- NAILS ----- ---- --- ------ w---- -�--- - ----- ----"------ NAILS & (18) 1/4"x2-3/4" S10 TAPCONS--- I I p o I I B2x12 TO SUPPORT STAIR LANDING FRAMING 1 A ® ------ -- GO 2 I r----- - I ('0 Ii.----- I - B2x8, FIELD VERIFY B ` BOTTOM OF BEAM FOR ® -ri -n -n _n STAIR CLEARANCE F5 UNDER w I N rV I N N N N D 4DO3 B2x8 SD1 H2x8 I 2x8 #2 SYP JOISTS AT 16" O.C. JOIST SHOULD r BUCKET INTO B2x8 W/ A35 I F4 FT4 E F1 i I I D03 CLIP AND BEAR OVER BW1 FLOOR SYSTEM. BWI I �. 18 g SD1 ® CONTRACTOR TO F1 L- — — — — PROVIDE 2x KNEEWALL S1 BELOW W/ STUDS AT 16"D5 BW1 2x4 SYP #2 BLOCKING @ 16" O.C. O.C. AS REQ'D ATTACH EACH END TO TRUSSES F1 W/ (3) 12d TOE -NAILS. ATTACH S1 BLOCKING TO WALL BELOW W/ D5 F4 D03 SIMPSON DTC CLIP F1 SD1 F1 M n E 4 18 D qF D02 S10 FT2 2 D D5 9 I D1 FSA r - E1 D2 2 F1 B2x10 TOP II F1 D E1 @ 11'-4" D D3 II El I 1 CJ �A CJ5 CJ3 l� CJ3 E2 GE01 Cil ICJ1 w U' cn w J y C-4 v D ROOF SHEATHING PER PLAN- ATTACH PER NAILING SCHEDULE TYPICAL TRUSS TO FRAME WALL LEGEND 11 CONNECTION. SEE L W LU JV STANDARD CONNECTOR 0 UJI MRB NOTES ZUj __ BEARING � PSQ-2171526 SEE PLAN _._. \I, ❑ ICJI PRE-ENGINEERED ROOF fel ® TRUSSES @ 24" O.C. SEE ARCHITECTURAL Q = 9'-4" T.O.M.= INTERIOR/EXTERIOR r ` PLAN FOR OVERHANG N 1/2" THREADED ROD FROM DOUBLE TOP PLATE TO C_ � CMU, MAINTAIN MIN. 7" EMBEDMENT INTO CMU DOUBLE 2X4 SPF #2 USING SIMPSON SET -XP EPDXY OR EQUAL SPACED CONTINUOUS TOP @ 32" O.C. AND 6" FROM ENDS. IF THE THREADED PLATE = 11'-4" T.O.M. IF REFERENCED ON SHEET w ROD IS NOT INSTALLED CONTINUOUS FROM TOP w cn PLATE TO CMU BELOW, THE CONTRACTOR MAY 24" LONG 15/32" INSTALL A MIN. SIMPSON CNW1/2 COUPLER NUT W/ PLYWOOD GUSSET ON WITNESS HOLES OR EQUAL v� w f CJ3F06 = KNEE WALL TOP ARCHITECTURAL PLANS BLOCKING TOE NAILED EACH STAGGERED END W/ (3) 12d NAILS, U.N.O. 12" LONG 15/32" PLYWOOD CJ3 _ GUSSET ON EACH FACE OF EACH STUD. (2) 8d NAILS @ MIN. 2x4 SPF #2 STUDS D _ @ 16" O.C., U.N.O. 24" LONG 15/32" PLYWOOD GUSSET ON EA. FACE OF EA. EXTERIOR FINISH CJ5 PER DESIGN PLAN STAGGERED EXTERIOR WALL ATTACH EACH BOTTOM PLATE TO CMU SHEATHING AND \ ��1 CJ5 NAILING PER PLAN 12" O.C. MAINTAINING A MINIMUM 2" 1-3/4" EMBEDMENT INTO THE CMU. THE MIN. CONTRACTOR SHALL BE RESPONSIBLE TO J VERIFY ALL PLIES OF THE BOTTOM PLATE ARE 2x4 SYP#2 P.T. NAILED/FASTENED TIGHT TO EACH OTHER SILL PLATE AND ALSO TIGHT TO THE CMU. BEARING NOTE TO CONTRACTOR: IF 2X8 SYP #2 P.T. 1 BOTTOM PLATE IS INSTALLED WITH 2X4 SYP - SEE PLAN A5 1-3/4" MIN. CLEAR FROM J WALL FRAMING, INSTALL (2) 1/4" X 6" TAPCONS CENTER OF 1/2" OR EQUAL @ 12" O.C. THRU DOUBLE BOTTOM THREADED ROD TO 1z EXTERIOR FACE OF CMU - - MSTAM24 EACH STUD TO WALL (@ 16" O.C. MASONRY WALL AND IL MAX) (9) 10d NAILS AND (5) 1/4" x 3-1/4" A4F TAPCONS PER STRAP F06 p D _ ALIGN FURRING STRIP BELOW w/ 2x4 A3 STUD ABV. & ATTACH FLAT STRAP TO - = A2 z W� 1x2 P.T. FURRING WALL SPLICE Al W/ DOUBLE STUD 0 Al ~_ > Z Q Al E G(D W Al LL Q U 0 W U ❑ Al ❑a�Q %i� /1 AlIII NOTE: COLUMN I X TO SUPPORT g I� _ _ J ❑ > LANDING BEAM zit W Al ONLY 19 5 V FTI ( ATTACH BEAM TO CMU I F1 USING HUC410 W/ (10) 10d ~ B2x12 TO SUPPORT p 2 NAILS & (18) 1/4"x2-3/4" - STAIR LANDING TAPCONS A FRAMING SEE DETAIL ST01/ST1 FOR = ___ N ADDITIONAL LANDING ------ II = FRAMING INFORMATION ATTACH BEAM TO CMU ®-------- A USING HUC410 W/ (10) 10d ---- ----"--------------- NAILS ----- ---- --- ------ w---- -�--- - ----- ----"------ NAILS & (18) 1/4"x2-3/4" S10 TAPCONS--- I I p o I I B2x12 TO SUPPORT STAIR LANDING FRAMING 1 A ® ------ -- GO 2 I r----- - I ('0 Ii.----- I - B2x8, FIELD VERIFY B ` BOTTOM OF BEAM FOR ® -ri -n -n _n STAIR CLEARANCE F5 UNDER w I N rV I N N N N D 4DO3 B2x8 SD1 H2x8 I 2x8 #2 SYP JOISTS AT 16" O.C. JOIST SHOULD r BUCKET INTO B2x8 W/ A35 I F4 FT4 E F1 i I I D03 CLIP AND BEAR OVER BW1 FLOOR SYSTEM. BWI I �. 18 g SD1 ® CONTRACTOR TO F1 L- — — — — PROVIDE 2x KNEEWALL S1 BELOW W/ STUDS AT 16"D5 BW1 2x4 SYP #2 BLOCKING @ 16" O.C. O.C. AS REQ'D ATTACH EACH END TO TRUSSES F1 W/ (3) 12d TOE -NAILS. ATTACH S1 BLOCKING TO WALL BELOW W/ D5 F4 D03 SIMPSON DTC CLIP F1 SD1 F1 M n E 4 18 D qF D02 S10 FT2 2 D D5 9 I D1 FSA r - E1 D2 2 F1 B2x10 TOP II F1 D E1 @ 11'-4" D D3 II El I 1 CJ �A CJ5 CJ3 l� CJ3 E2 GE01 Cil ICJ1 w U' cn w J y C-4 v D ROOF SHEATHING PER PLAN- ATTACH PER NAILING SCHEDULE TYPICAL TRUSS TO FRAME WALL LEGEND 11 CONNECTION. SEE L W LU JV STANDARD CONNECTOR 0 UJI MRB NOTES ZUj BEARING AIL PSQ-2171526 SEE PLAN _._. _ ❑ 0 PRE-ENGINEERED ROOF Q O W r, > CK TRUSSES @ 24" O.C. SEE ARCHITECTURAL Q = 9'-4" T.O.M.= INTERIOR/EXTERIOR MIN. ASTM F1554 GRADE 36 Fy=36ksi & FU=58ksi, PLAN FOR OVERHANG N 1/2" THREADED ROD FROM DOUBLE TOP PLATE TO INFO CMU, MAINTAIN MIN. 7" EMBEDMENT INTO CMU DOUBLE 2X4 SPF #2 USING SIMPSON SET -XP EPDXY OR EQUAL SPACED CONTINUOUS TOP @ 32" O.C. AND 6" FROM ENDS. IF THE THREADED PLATE = 11'-4" T.O.M. IF REFERENCED ON SHEET w ROD IS NOT INSTALLED CONTINUOUS FROM TOP PLATE TO CMU BELOW, THE CONTRACTOR MAY 24" LONG 15/32" INSTALL A MIN. SIMPSON CNW1/2 COUPLER NUT W/ PLYWOOD GUSSET ON WITNESS HOLES OR EQUAL EA. FACE OF EA. STUD. 2x4 SPF #2 MID -POINT (2) 8d NAILS @ 4" ac = KNEE WALL TOP ARCHITECTURAL PLANS BLOCKING TOE NAILED EACH STAGGERED END W/ (3) 12d NAILS, U.N.O. 12" LONG 15/32" PLYWOOD @ 11'-4" U.N.O. _ GUSSET ON EACH FACE OF EACH STUD. (2) 8d NAILS @ MIN. 2x4 SPF #2 STUDS 4" O.C. STAGGERED _ @ 16" O.C., U.N.O. 24" LONG 15/32" PLYWOOD GUSSET ON EA. FACE OF EA. EXTERIOR FINISH STUD. (2) 8d NAILS @ 4" O.C. PER DESIGN PLAN STAGGERED EXTERIOR WALL ATTACH EACH BOTTOM PLATE TO CMU SHEATHING AND \ BELOW USING (2) 1/4" TAPCONS OR EQUAL @ NAILING PER PLAN 12" O.C. MAINTAINING A MINIMUM 2" 1-3/4" EMBEDMENT INTO THE CMU. THE MIN. CONTRACTOR SHALL BE RESPONSIBLE TO J VERIFY ALL PLIES OF THE BOTTOM PLATE ARE 2x4 SYP#2 P.T. NAILED/FASTENED TIGHT TO EACH OTHER SILL PLATE AND ALSO TIGHT TO THE CMU. BEARING NOTE TO CONTRACTOR: IF 2X8 SYP #2 P.T. W BOTTOM PLATE IS INSTALLED WITH 2X4 SYP - SEE PLAN #2 BOTTOM PLATES ABOVE FOR DOUBLE 1-3/4" MIN. CLEAR FROM J WALL FRAMING, INSTALL (2) 1/4" X 6" TAPCONS CENTER OF 1/2" OR EQUAL @ 12" O.C. THRU DOUBLE BOTTOM THREADED ROD TO PLATE TO CMU BELOW EXTERIOR FACE OF CMU - - MSTAM24 EACH STUD TO WALL (@ 16" O.C. MASONRY WALL AND IL MAX) (9) 10d NAILS AND (5) 1/4" x 3-1/4" REINFORCEMENT PER TAPCONS PER STRAP PLAN _ ALIGN FURRING STRIP BELOW w/ 2x4 - STUD ABV. & ATTACH FLAT STRAP TO - = CMU w/ 1/4"x3-1/4" LONG TAPCONS z W� 1x2 P.T. FURRING WALL SPLICE DETAILS W/ DOUBLE STUD CLEAR STORY REPAIR DETAIL 3/4"=1'-0" N BLDG DESIGN: --- STRUCTURALENG: MCD DRAFTING: -DESIG WALL LEGEND 11 W; L W LU JV U 0 UJI MRB _Uj ZUj �- co N c� o cti PSQ-2171526 SCALE: �- a a ❑ 0 Q o Q O W r, > CK Q = 9'-4" T.O.M.= INTERIOR/EXTERIOR 0 BEARING WALL (OR LINTEL -J = 11'-4" T.O.M. IF REFERENCED ON SHEET w S4). VERIFY HEIGHT W/ T_ = KNEE WALL TOP ARCHITECTURAL PLANS w @ 11'-4" U.N.O. O Z O J p w W ❑ C1_ CL W W IL _ H o O z W� o 0 0 ~_ > Z Q E W U LL Q U 0 W U ❑ ❑a�Q ❑ > zit W N ( w I—w w I- ,�,,oa��ara �> � co,y U y oo ,oaoouoon /j/ 'ju' w G O u' • ��Z c ROOF SHEATHING PER Z6z o9U� o = Q U PLAN -ATTACH PER NAILING SCHEDULE -- _ Ow � r �; `- C)J U)Le , ��° �- �° G LLI 4E$ � TYPICAL TRUSS TO FRAME � " o z ��: 7d ��"~ }� O �- CONNECTION. SEE Q '°/, \ pQ. ,���,®gy m Lei STANDARD CONNECTOR W��-`— NOTES U Q` BEARING G \ SEE PLAN 0� Z PRE -ENGIN ERED U) ❑ ROOF TRUSSES @ 24 ¢ w a gfN �f> N SEE ARCHITECTURAL O.C. U J 6 PLAN FOR OVERHANG MIN. ASTM F1554 GRADE 36 Fy=36ksi & O -� o INFO FU=58ksi, 1/2" THREADED ROD FROM z N O U z 0 DOUBLE 2X8 SPF #2 DOUBLE TOP PLATE TO CMU, MAINTAIN O 17--Z o CONTINUOUS TOP MIN. 7" EMBEDMENT INTO CMU USING Q O PLATE SIMPSON, SET -XP EPDXY OR EQUAL U SPACED @ `32" O.C. AND 6" FROM ENDS. IF THE THREADED ROD IS NOT w INSTALLED CONTINUOUS FROM TOP w❑ PLATE TO CMU BELOW, THE = O ' CONTRACTOR MAY INSTALL A MIN. O SIMPSON CNW1/2 COUPLER NUT W/ �q WITNESS HOLES OR EQUAL U 6�1 z - O 2x8 SPF # 2 S"IUDS @ — 0 16" O.C. U.N.O.m Z 2x8 SPF #2 MID -POINT BLOCKING OU ih• o EXTERIOR FINISH TOE NAILED EACH END W/ (3) 12d U (n U r- o J PER DESIGN PLAN NAILS, U.N.O. z N O w c E LU _ 1--Z "17) o EXTERIOR WALL ATTACH BOTTOM PLATE TO CMU 0 CY SHEATHING AND BELOW USING 2 1/4" TAPCONS OR O O 7 U 0 0 � Q0 zoQ c�� NAILING PER PLAN EQUAL @ 12" O.C. MAINTAINING A B- 0 N w Z . in MINIMUM 2" EMBEDMENT INTO THE CMU. -1 Q O o o IL 1-3/4" THE CONTRACTOR SHALL VERIFY THE z �zpl=-�Luul o MIN. BOTTOM PLATE IS FASTENED TIGHT TO Q O � Q w O 2x8 SYP#2 P.T. THE CMU. FOR SINGLE PLATE TO CMU; z 00 --, O U LL U SILL PLATE IF J -BOLTS ARE INSTALLED @ 32" O.C. & 6" FROM ® T ENDS AND PLATE SPLICES, Z BEARING THE TAPCONS AS DETAILED ABOVE ARE LL Z p w N Q SEE PLAN - NO"f REQUIRED. W Q U _ 1-3/4" MIN. CLEAR FROM CENTER OF 1/2" _ _ MSTAM24 EACH STUD TO WALL ~ rr�� THREADED ROD TO - (@ 16" O.C. MAX) z v✓ EXTERIOR FACE OF CMU - _ (9) 10d NAILS AND (5) 1/4" x 3-1/4" Q W ' - = TAPCONS PER STRAP U) LLI MASONRY WALL AND - ALIGN FURRING STRIP T � REINFORCEMENT PER = BELOW w/ 2x4 STUD ABV. & 3: U) PLAN - ATTACH FLAT STRAP TO CMU O w/ 1/4"x3-1/4" LONG TAPCONS p m 1x2 P.T. FURRING z Z r W ® 0 WALL SPLICE DETAILS W/ SINGLE STUD w ❑ P: N BLDG DESIGN: --- STRUCTURALENG: MCD DRAFTING: -DESIG (n > 11 u1 L W LU JV U 0 UJI MRB _Uj ZUj SA�,FoRD Q w PSQ-2171526 SCALE: �- a a U 0) 0 _ O W r, > CK N BLDG DESIGN: --- STRUCTURALENG: MCD DRAFTING: -DESIG FIRST FLOOR FRAMING PLAN" DATE E: SEE PAGE S6 FOR NOTES AND CONNECTOR LEGEND 1/4"= 1 1-011 �-28.80 _COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. 17 N. --- -STRUCT: - JV 6J��DING QC CHECK: MRB SA�,FoRD JOB No. PSQ-2171526 SCALE: AS INDICATED FIRST FLOOR FRAMING PLAN" DATE E: SEE PAGE S6 FOR NOTES AND CONNECTOR LEGEND 1/4"= 1 1-011 �-28.80 _COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. 17 Revision 9 Response to Comments ❑ Permit # r Project Address: Lei- * lyy City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Submittal Date !:-,5% I V [l � ` i cls --ten, Contact: � � � V 1 A IJ Ph: Fax: Email: _ � � CJ � 4 q �oy,�Q� • � �n Trades encompassed in revision: Building ❑ Plumbing ❑ Electrical ❑ Mechanical ❑ LiFe Safety ❑ Waste Water General description of revision: "(,J agr--C(ow ROUTING INFORMATION Department Approvals ❑ Utilities ❑ Waste Water ❑ Planning ❑ Engineering ❑ Fire Prevention ❑ Building tv SHEET INDEX: 00 COVER SHEET 01 SLAB PLAN 02 FIRST FLOOR .03 SECOND FLOOR 04B EXT. ELEVATION B, FRONT & REAR 05B EXT. ELEVATION B, LEFT & RIGHT 06 CROSS SECTION/STAIR SECTION 07 ELECTRICAL LAYOUT FIRST FLOOR 08 ELECTRICAL LAYOUT SECOND FLOOR D1 TYPICAL DETAILS REVISION SCHEDULE: NO: DATE: DESCRIPTION: BY: 1 01/23/17 BEDROOM 5 OPTION J.L. 2 05/08/18 REVISED SECOND FLOOR PER NEW FLOOR PLAN LAYOUT C.C. ,tEcolw COPY W O � �¢ 00 V) � Y W ry O U W O O W Z O cn z� w� Cr ¢w a. V) Z z CD V) - O$ o� ¢w zV) u� wF o� 00 z V) ¢� o¢ vi n" zo w UlZ W Q 0 VJ Q W V) IL Q O m t O r zw O F MW O ry U Q V) I r-- - O w� z 7 � W W W 0 r Q L z W T z (� O W 00 T W L�1 ry F- or 2 Y Z fY <L Z O GENERAL NOTES FOUNDATIONS SOIL UNDER SLABS AND UNDER FOOTINGS TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM- 1557 (MODIFIED PROCTOR) MINIMUM BEARING CAPACITY 2000 PSF TERMITE TREATMENT THE SOIL UNDER THIS STRUCTURE SHALL BE TREATED FOR THE PREVENTION OF SUBTERRANEAN TERMITES, OR A PERIMITER TREATMENT (BORACARE) MAY BE USED, IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. CAST IN PLACE CONCRETE 1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2500 PSI, A SLUMP OF 4" PLUS OR MINUS 1", AND HAVE 2 TO 4% AIR ENTRAINMENT, AND A MAXIMUM WATER/CEMENT RATIO OF 0.58. 2. ALL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 GRADE 60 3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 FOR 6x6xW1.4xW1.4 WWF SHALL BE LAPPED AT LEAST 6" & CONTAIN AT LEAST ONE CROSS WIRE WITHIN THE 6".FIBERMIX OF EQUAL SPECIFICATIONS MAY BE USED IN LIEU OF WWF, 4. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH "THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" ACI 318 LATEST EDITION, AND SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS," ACI 301. 5. HORIZONTAL FOOTING BARS SHALL BE BENT MIN. 12 BAR DIAMETERS (EXCLUDING BEND) AROUND CORNERS OR CORNER BARS WITH MIN. 30" LAP EXCLUDING BEND AT EACH END SHALL BE PROVIDED. 6. MINIMUM LAP SPLICES ON ALL REINFORCING BARS SHALL BE 48 BAR DIAMETERS. 7. SLAB ON GRADE, REINFORCEMENT SHALL BE SUPPORTED IN PLACE FROM THE CENTER TO UPPER 1/3 OF THE SLAB. BOLTS AND THREADED RODS 1. ALL BOLTS & THREADED RODS TO BE ASTM A307 OR BETTER (U.N.O.) 2. STEEL BOLTS LESS THAN ONE -HALF-INCH (12.7 mm) IN DIAMETER USED AS FASTENERS FOR PRESSURE PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. 3. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS SHALL BE PERMITTED TO BE OF MECHANICALLY DEPOSITED ZINC -COATED STEEL WITH COATING WEIGHTS IN ACCORDANCE WITH ASTM B 695, CLASS 55, MINIMUM. MASONRY WALL CONSTRUCTION 1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, W/ A MINIMUM NET COMPRESSIVE STRENGTH OF 2000 PSI (fm = 1900 PSI) 2. MORTAR SHALL BE TYPE M OR S, CONFORMING TO ASTM C270 3. HEAD MORTAR JOINTS AT PRECAST WINDOW SILLS TO BE NO MORE THAN 111 . 4. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. 5. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS WITH CELLS FILLED WITH COARSE GROUT AND GRADE 60 STEEL. REINFORCEMENT SHALL BE PLACED IN CENTER OF MASONRY CELL W/ MIN 1/2" CLEARANCE TO INSIDE FACE. 6. VERTICAL REINFORCEMENT SHALL BE HELD IN CENTER OF THE MASONRY/ BLOCK WALL AT THE TOP & BOTTOM & MAXIMUM 8'-0" U.N.O. VERITCALLY. TIES TO THE FOOTING & LINTEL STEEL IS ADEQUATE @ TOP & BOTTOM OF WALL; REBAR POSITIONERS IN MIDDLE OF WALL 7. REINFORCING STEEL SHALL BE LAPPED MIN. 25" U.N.O. 8. HOOKS AT THE TOP & BOTTOM OF VERTICAL REINFORCING BARS TO BOND COURSE AND FOOTING TO BE NO LESS THAN 12 BAR DIAMETERS EXCLUDING BEND 9. EXPANSION TYPE ANCHORS ARE NOT TO BE USED IN BOND COURSE. EMBEDDED ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. 10. MASONRY ROUGH OPENING TOLERANCES - 1/4" TO + 1/2" 11. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC SCREEN, METAL LATH STRIP OR CAVITY CAPS MAY BE USED TO PREVENT THE FLOW OF GROUT INTO CELLS BELOW. THE USE OF FELT PAPER AS A STOP IS PROHIBITED. 12. TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR 13. DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS AND NO CONCENTRATED LOADS FOR (7) DAYS. PER CODE ACI 318, LATEST EDITION. 14. DURING CONCRETE POURS, GC TO ADEQUATELY VIBRATE THE FILLED CELL W/ EITHER RODDING OR PENCIL VIBRATOR TO ENSURE PROPER CONCRETE CONSOLIDATION. WOOD CONSTRUCTION 1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION", LATEST EDITION.(NDS) 2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS. SHEAR WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS. (I.E. BLOCKING OR GABLE END BRACING), SHALL BE SPRUCE- PINE -FIR OR EQUIVALENT. NO. 2 GRADE SHALL BE USED REGARDLESS OF SPECIES U.N.O. ON FRAMING PLANS OR DETAILS. END -JOINTED LUMBER IS NOT PERMITTED TO BE USED IN ANY LOAD BEARING (GRAVITY OR WIND) CONDITIONS. E.O.R. TO REVIEW IF INSTALLED. 3. FIELD -CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE -TREATED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. 4. THE PORTIONS OF GLUED -LAMINATED TIMBERS THAT FORM THE STRUCTURAL SUPPORTS OF A BUILDING OR OTHER STRUCTURE AND ARE EXPOSED TO WEATHER AND NOT PROPERLY PROTECTED BY A ROOF, EAVE OR SIMILAR COVERING SHALL BE PRESSURE TREATED WITH PRESERVATIVE, OR BE MANUFACTURED FROM NATURALLY DURABLE OR PRESERVATIVE -TREATED WOOD. 5. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY (MOISTURE CONTENT 19% OR LESS), U.N.O. ALL WATERPROOFING AND FIRE SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHERS. 6. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT HAVE HOLES IN THE CENTER OF THE STUD UP TO 1" DIA. SHALL HAVE STUD PROTECTION SHEILDS. ALL HOLES OVER 1" IN DIA FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH SIMPSON HSS2 STUD SHOES, TYP U.N.O. 7, MANY OF THE PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE BUILDER'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE. ACQ-C, ACQ-D, CBA -A OR CA -B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOR SODIUM BORATE (SBX) DOES NOT. 8. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH, CONCRETE OR MASONRY IS TO BE PRESSURE TREATED. 9. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE OR MASONRY. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES, 10. SEE PLAN FOR BUILT UP STUD COLUMN AND BEAM NAILING PATTERNS ENGINEERED LUMBER WIND DESIGN LOAD INFORMATION WIND SPEED (ULTIMATE) 140 mph ALL ENGINEERED LUMBER IS TO HAVE THE MINIMUM DESIGN VALUES AS FOLLOWS: RISK CATEGORY II BUILDING TYPE V B COLUMNS BEAMS STUD E = 1,700,000 Ib/int U.N.O. E = 2,000,000 Ib/int U.N.O. E = 1,500,000 Ib/int U.N.O. Fb =2650 Fb =3000 Fb =2200 Ft = 1650 Ft = 1700 Ft= 1500 Fc 11= 3000 Fc 11= 3000 Fc 1�= 2100 Fc 1= 450 Fc = 900 Fc = 450 Fv = 285 Fv =285 Fv = 150 WOOD BEARING SURFACES ARE TO BE SYP#2 OR BETTER END GRAIN CONDITION U.N.O. CEILING CONSTRUCTION 1. USE 1/2" CEILING OR SAG RESISTANT BOARD FOR 24" O.C. FRAMING U.N.O. 2. 5/8" TYPE "X" GYPSUM BOARD SHALL BE USED ON CEILING IN GARAGE WHEN LIVING SPACE IS ABOVE THE GARAGE. MEANS AND METHODS CONSTRUCTION MEANS & METHODS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE STRUCTURE IS UNSTABLE UNTIL ALL LOAD BEARING WALLS ARE ERECTED & TRUSS / FRAME MEMBERS ARE CONNECTED PROPERLY PER APPROVED FRAMING PLANS / DETAILS ALONG W/ CONNECTOR & COMPONENT MANUFACTURERS' SPECIFICATIONS. UNTIL SUCH TIME, TEMPORARY BRACING & SHORING OF WALLS AND FRAME MEMBERS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. UNDER STAIR PROTECTION 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2 -INCH (12.7MM) GYPSUM BOARD. METAL COATINGS FOR USE WITH PRESSURE TREATED WOOD IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT ALL METAL CONNECTORS, METAL FASTENERS, ANCHORS, AND NAILS ARE THE APPROPRIATE MATERIAL AND/OR HAVE THE APPROPRIATE COATING FOR USE WITH THE DIFFERENT TYPES OF PRESSURE TREATED WOODS, AS PER THE FOLLOWING GUIDELINES. 1. WOOD TREATED WITH DOT SODIUM BORATE(SBX): CONNECTORS SHALL BEA MINIMUM G50 ZINC COATING 2. WOOD TREATED WITH ACQ-C OR ACQ-D (CARBONATE) OR OTHER BORATE (NON -DOT) TREATMENTS: CONNECTORS SHALL BE A MINIMUM G185 ZINC COATING. 3. FOR ALL OTHER COMBINATIONS FOLLOW THE RECOMMENDATIONS OF THE PRESERVATIVE WOOD TREATER. 4. STAINLESS STEEL CONNECTORS AND FASTENERS MAYBE USED WITH ALL TYPES OF PRESSURE TREATED WOOD. PREFABRICATED WOOD TRUSSES 1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH HURRICANE CLIPS OR ANCHORS.UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT OR LATERAL FORCES. INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE COORDINATE WITH THE TRUSS ENGINEER FOR THE LOCATION OF THESE WALLS AND STRUCTURAL PLANS FOR MORE INFO. 2. TRUSSES SHALL BE DESIGNED BY MWFRS METHODOLOGY FOR LONG SPAN TRUSSES TO DETERMINE UPLIFT AND REACTION VALUES. MEMBER AND PLATE DESIGN TO BE CALCULATED BY COMPONENTS AND CLADDING METHOD UNLESS SPECIFIED OTHERWISE BY TRUSS ENGINEER OF RECORD 3. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI TPI 1. 4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS REQUIRED BY TRUSS MANUFACTURER UNLESS NOTED ON PLANS 5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE NOT SHOWN, BUT SHALL BE DESIGNED BY TRUSS MANUFACTURER IN ACCORDANCE WITH THE DESIGN LOADS. TRUSS DESIGN LOADS: TOP CHORD: Lr = 16 PSF DL = 7 PSF (SHINGLE TYPE ROOF COVER) DL = 15 PSF (LIGHT WEIGHT CLAY TILE ROOF COVER) DL = 14 PSF (TRUSS OVERBUILD) ' BOTTOM CHORD: DL = 5 PSF MINIMUM FLOOR DESIGN LIVE LOADS: A) FLOORS = 40 PSF B) BALCONIES =60 PSF / 100 PSF (IF BALCONY > 100 SQ FT) C) DECKS = 40 PSF D) STAIRS = 40 PSF E) BONUS ROOM/GAME ROOMS = 60 PSF U.N.O. MINIMUM FLOOR DESIGN DEAD LOADS: A) FLOORS = 15 PSF B)BALCONIES = 15 PSF GENERAL LOADING: ATTIC WITHOUT STORAGE = 10 PSF ATTIC WITH LIMITED STORAGE = 20 PSF GUARDRAILS / HANDRAILS = 200 LB POINT LOAD / 50 PSF GUARDRAILS IN -FILL COMPONENTS = 50 PSF GENERAL TRUSS BRACING & BLOCKING REQUIREMENTS -ADDIT'L BRACING & BLOCKING PER BCSI-1 & TRUSS MANUFACTURER'S DWGS -G.C. TO PROVIDE MIN 2x SYP #2 BLOCKING BETWEEN TRUSSES TO COMPLY W/ APA RECOMMENDATIONS FOR MIN. 7/16" OSB SHEATHING -MIN 2x SYP #2 BLOCKING REQ'D ALONGSIDE TRUSS TOP CHORD @ ROOF HIP/RIDGE TO PREVENT SHEATHING SPAN FROM EXCEEDING 2FT (NOT REQ'D IF SHEATHING SPAN IS LESS THAN 2FT). BLOCKING TO TRUSS TOP CHORD w/ (2) 12d NAILS @ 12" O.C. MAX & 4" FROM EA. END. NOTE: PLYWOOD EDGES @ HIP CORNERS REQUIRE MIN 2x4 SYP #2 BLOCKING w/ (3) 12d TOENAILS EACH END. -TRUSS "X" BRACING: MIN 2x4 SYP #2 AT ANGLE APPROX. 45° FROM VERT. TO EA. TRUSS MEMBER w/ (3) 12d NAILS. SPACE "X" BRACING ALONG TRUSS SPAN @ 10'-0" MAX AND E EQUALLY SPACED FROM END OF TRUSS. "X" BRACING TO START 20'-0" MAX FROM #1 HIP GIRDER AND / OR (4) BAYS AFTER GABLE END BRACING. SEE BCSI-B3 SECTIONS 1, 2 AND 3 FOR ADDITIONAL ROOF PLANE PERMANENT BRACING REQUIREMENTS. -PERMANENT 2x4 SPF #2 (MIN.) CONT. LATERAL TRUSS BOTTOM CHORD BRACING PERPENDICULAR TO TRUSS SPAN AT 15'-0" O.C. MAX W/IN TRUSS SPAN OR PER TRUSS DESIGN DRAWINGS. ATTACH W/ (2) 16d NAILS AT EACH TRUSS. OVERLAP BRACING AT LEAST ONE TRUSS SPACE (24") PLUS 6" MIN PAST BOTTOM CHORD. -INSTALL PERMANENT 2x CONTINUOUS LATERAL BRACE (CLB) ACROSS TRUSS WEBS AS INDICATED ON TRUSS SHOP DRAWINGS & BCSI-133. ("T" BRACING MAY BE USED I.L.O. PEMANENT CLB IF IT EXTENDS MIN. 90% OF THE TRUSS WEB (SEE WEB REINFORCEMENT FABLE WITHIN BCSI-B3). -AT RAISED HEEL TRUSSES, 2x4 SYP #2 (MIN.) AT TOP AND BOTTOM OF HEEL W/ (2) 12d TOENAILS REQ'D. EXT. SHEATHING MUST BE ATTACHED TO RAISED HEEL TRUSS AND INDICATED BLOCKING. ALTERNATE IF HEEL HEIGHT IS LESS THAN 12" TALL: 2x4 SYP #2 BEHIND THE TRUSS VERT. RUNNING FROM TOP TO BOTTOM ACROSS MAX 4 TRUSSES, THEN BOTTOM TO TOP W/ (2) 12d NAILS AT EACH TRUSS MEMBER (DIAGONAL BRACING) DIAGONAL BRACING REQUIRED AT CLB PER BCSI-B3. 6. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS, WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. 1. OMITTED REBAR DRILLA 3/4" O HOLE MIN. 6" DEEP AT LOCATION OF OMITTED REBAR, AND INSTALL #5 BAR INTO EPDXY FILLED HOLE. EPDXY TO BE SIMPSON STRONG TIE EPDXY OR EQ. FOLLOW MANU'S INSTRUCTIONS. ASSURE ALL DUST AND DEBRIS FROM DRILLING ARE REMOVED FROM HOLE w/ COMPRESSED AIR PRIOR TO APPLYING EPDXY. ALLOW EPDXY TO CURE TO MANU'S SPECIFICATIONS, THEN FILL CELL IN NORMAL WAY DURING BONDBEAM POUR. USE 30" MIN. LAP SPLICE. HOOKS AT TOP OF BAR TO BE MIN. 12 BAR DIAMETERS(EXCLUDING BEND). 2. STRAPS/CONNECTOR SUBSTITUTION MAY SUB STRAPS/CONNECTORS w/ STRAPS/CONNECTORS OF EQUAL OR GREATER UPLIFT & LATERAL RESISTANCE VALUES IN FIELD WITHOUT VERIFICATION, PROVIDED ALL MANUFACTURER'S INSTALLATION INSTRUCTIONS ARE FOLLOWED. 3. STAIR CONSTRUCTION 2X12'S MAY BE USED ILO TIMBERSTRANDS FOR STAIR STRINGERS. RIM BOARDS MAY BE USED FOR RISERS & TREADS ILO 2x12'S (SEE GEN. STAIR DEPS FOR ADDIT'L INFO.) 4. METAL STUD SUBSTITUTION WOOD STUDS MAY BE SUBBED w/ METAL STUDS IN NON -LOAD BEARING WALLS 5. OMITTED J -BOLT -1/2" ALL THREAD ROD w/ 2" x 2" SQ. WASHER DRILL &EPDXY w/ SIMPSON SET EPDXY WITH MIN. 7" EMBEDMENT. -1/2"x6" SIMPSON TITEN HD THREADED ANCHORS W/ LBP1/2 WASHER MAY BE USED ILO 1/2" J -BOLT. TAPCON FASTENERS MAY BE USED ILO SIMPSON TITENS 6. MORTAR JOINTS -FOR BED JOINTS 1/2"-1", GROUT FILL CELLS IN BLOCK AFFECTED (NO VERT. REINF. REQ'D) -FOR HEAD JOINTS GREATER THAN 3/4", GROUT FILL CELL IN BLOCKAFFECTED ON EA.SIDE OF JOINT. PROVIDE (1) #5 VERT. REINF. IN EA. CELL CONT. PER PLAN. "EXCEPTION: IF TIE BEAM COURSE AND ADJ. TWO COURSES BELOW, AS WELL AS 1st (2) COURSES FROM FND. HAVE HEAD JOINTS WHICH FALL W/IN THE SPECIFIED TOLERANCES, THE ADDED VERTICAL REINFORCEMENT IS NOT REQ'D TO BE EPDXIED INTO TIE BEAM/FTG -FOR BLOCKS NOT STAGGERED, GROUT FILL CELL EA. SIDE OF JOINT AND PROVIDE (1) #5 VERT. REINF. IN EA. CELL, CONT. PER PLAN. 7. OVERHANGING CMU WALL -FOR CMU OVERHANGING FOUNDATION <1/2", NO FIX IS REQ'D POUR TIEBEAM & VERT. CELLS PER PLAN. -FOR CMU OVERHANGING FOUNDATION FROM +1/2"-1-1/8", GROUT FILL FIRST (3) COURSES IN WALL ALONG AREA AFFECTED & TIE BEAM AND VERTICAL CELLS PER PLAN -FOR CMU OVERHANGING FOUNDATION OVER 1-1/8", CONTACT EOR FOR REPAIRS. STRUCTURAL STEEL 1. MATERIAL SPECS: WIDE FLANGE SECTIONS: ASTM A992, GRADE 36, Fy=36 KSI. TUBE STEEL (HSS): ASTM A500, GRADE B, Fy = 46 KSI. PIPE STEEL: ASTM A53, TYPE E OR S, Fy = 35 KSI. ALL OTHER STRUCTURAL & MISC. STEEL: A36 Fy=36 KSI. 2. STRUCT. CONNECTIONS: ALL STRUCT. BOLTS TO BE A325N U.N.O. ALL A325N BOLTS SHALL BE AT "SNUG -TIGHT" CONDITION AS DEFINED IN THE SPEC. SLIP CRITICAL (SC) BOLTS MUST BE FULLY TENSIONED PER SPEC STRUCT. BOLTS SMALLER THAN 5/8" DIA. TO BE A307 THREADED ROD & CONFORM TO A36 OR A307 ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 SHOP AND FIELD WELDS: E70XX ELECTRODES STEEL REINF.T SHOP DWGS TO BE PROVIDED TO EOR BEFORE FABRICATION FOR REVIEW AND APPROVAL. WELDED CONNECTIONS: ELECTRODES - E70XX UNO (LOW HYDROGEN). FILLET WELDS SHALL BE Y/6" UNO, 3. SUBMIT SHOP DWGS INDICATING ALL SHOP AND ERECTION DETAILS INC. PROFILES, SIZES, SPACING, & LOCATIONS OF STRUCTURAL MEMBERS, CONNECTION ATTACHMENTS, FASTENERS, LOAD, AND TOLERANCES. 4. STRUCTURAL STEEL SHALL RECEIVE SHOP COAT OF PRIMER (COLOR AS DIRECTED BY ARCHITECT) EXCEPT FOR AREAS WHICH WILL RECEIVE SPRAY -ON FIRE PROTECTION. 5. A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND SPECS (IF PROVIDED). SUBMIT REPORTS TO ARCHITECT AND ENGINEER. DESIGN PRESSURES WIND DESIGN LOAD INFORMATION WIND SPEED (ULTIMATE) 140 mph WIND SPEED (ALLOWABLE) 108 mph WIND EXPOSURE B RISK CATEGORY II BUILDING TYPE V B ENCLOSURE CLASSIFICATION ENCLOSED INTERNAL PRESSURE COEFFICIENT +/-0.18 ° J WIND PRESSURE & SUCTION EFFECTIVE (PSF) WIND (+) VALUE DENOTES PRESSURE AREA (SQ FT) (_) VALUE DENOTES SUCTION AREA O 5O z O U),- (+) 21.2 (+) 21.2 10 (-) 22.9 (-) 28.3 DOWEL PLACEMENT PLAN (+) 20.2 (+) 20.2 20 (-) 22.0 (-) 26.4 FOUNDATION DETAILS (+) 19.0 (+) 19.0 50 (-) 20.8 (-) 23.9 100 (+) 18.0 (+) 18.0 U) (-) 19.8 - 22.0 GARAGE DOORS 9'-0" x 7'-0" 16-0" x 7'-0" w (+)18.4 +177 (-) 20.9 S6 WIND PRESSURE/ SUCTION DIAGRAM 5 5 44 ,a I 5 5 fes' °BIW -z�LL STANDARD DESIGN PRESSURE NOTES 1. ASCE 7-10 WALL DESIGN ALLOWABLE COMPONENTS AND CLADDING WIND PRESSURES AND SUCTIONS PER FLORIDA BUILDING CODE 5th EDITION (2014). WIND SPEED IS BASED ON LINEAR INTERPOLATION FOR THIS SITE. 2. MEAN ROOF HEIGHT FOR A TYPICAL SINGLE STORY HOME IS 15FT, 2 STORY HOME IS 30FT 3. MULTIPLY THE ABOVE PRESSURES BY 1.67 TO GET ULTIMATE WIND PRESSURES. 4. "a" = END ZONE IS ONLY W/IN 5'-0" OF ALL EXTERIOR BUILDING CORNERS. 5. INDICATED PRESSURES CAN BE INTERPOLATED FOR OTHER DOOR SIZES, OTHERWISE USE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREAS. 6. DESIGNATED AREAS WHERE THE ULTIMATE WIND SPEED IS 140 MPH OR GREATER IS CONSIDERED TO BE IN THE WIND -BOURNE DEBRIS AREA. OPENING PROTECTION REQUIRED. REFER TO SECTION R301.2.1.2 OF THE RESIDENTIAL CODE FOR SPECIFICATION REQUIREMENTS OF THE USE OF WOOD STRUCTURAL PANELS. REFER TO TABLE R301.2.1.2 FOR ATTACHMENT SPECIFICATIONS INDEX OF DRAWINGS � co Q Co ❑ SHEET SHEET TITLE ° J l�f� N o w W SC STRUCTURAL NOTES O N (y)� U. - z O U),- O S113 FOUNDATION PLAN z S213 DOWEL PLACEMENT PLAN O co 0 0 S3 FOUNDATION DETAILS ° a (D D- U S413 LINTEL PLAN CK W z w U) I S51 FIRST FLOOR FRAMING PLAN °- J J v d w Q n.. L U)U M W J C7 r � S6 NOTES & CONNECTOR LEGEND f- °BIW -z�LL S713 ROOF FRAMING PLAN W w O W z 5 SD1 GENERAL DETAILS J o zzI-�ww o pXQwZO SD2 GENERAL DETAILS IN Q�°cgQc- SD3 GENERAL DETAILS LL N SD4 GENERAL DETAILS' O00NQ F- D a SD5 2 -STORY DETAILS Q s U w S D6 2 -STORY DETAILS ° z ST1 GENERAL STAIR DETAILS ° cis 0 IM Z r. la - ® F_ ua F-- U F- co �I �W ❑ Q W LL_ O Z O ®0) Q U O W W z W LU z H T F - - w U i/1 z Q O U CL Q z W U) BLDG DESIGN: Ll z MCU 0 MASTER UPDATES Q ° ❑ z NUMBER DATE DESCRIPTION INTIALS w MRB JOB No. PSQ-2171526 SCALE: AS INDICATED DATE: 1 2/17/2017 CREATED ELEV A, B, C, & OPTIONAL BEDROOM#5 DP z F-- 2 4/10/2016 QC CLEANUP - ADDED MISSING CALL OUT TO FRAMING PLAN DP COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTH CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. W � co co Co W ❑ :- r- `o l�f� N o o M ( O N (y)� O z O U),- a � w W O J U U ❑ (D 0 0 0 uJ a OD LLf ii p° v0p Y/� v z °C9 U CC) v LLl Wrslf 111sa a����� m Q J N O O W ❑ • 4 `VOr, ° Iiico W l�f� N o W M Q O z 0 z O U),- a � w W O J U U _r_ LO G�ti � l • Y z 0 F- 0 ( z 06 o O ❑ (D D- U Q a � LL 0� 0 ❑ w z w U) z . W p v d w o ¢ n.. L U)U M W J C7 r � �<KJ�Vly)_r °BIW -z�LL uJ a OD LLf ii p° v0p Y/� v z °C9 U CC) v LLl Wrslf 111sa a����� m Q Z o W ❑ • 4 `VOr, ° Iiico W l�f� N o C; Q O z 0 O F- • zLU Q� U _r_ LO G�ti � l • Y W ❑ v�titi O O U (D im D J U) z . M W CD r- U)U M W J C7 r � ❑ C/ w E o °BIW -z�LL ZUF-❑Oco O W z 5 zzI-�ww o pXQwZO D Q�°cgQc- LL N W C) O00NQ F- D W T_® o 0 IM Z r. ® F_ o �I �W �e 5 LU ®0) LU W z W LU �U ®3: i/1 O ®! 00 CL �..®.�, C N BLDG DESIGN: --- S'rRUC'rURAL ENG: MCU DRAFTING: -DESIGN: --- -STRUCT: JV QC CHECK: MRB JOB No. PSQ-2171526 SCALE: AS INDICATED DATE: 08/28/2017 NOTE: SEE PAGE S6 FOR NOTES AND CONNECTOR LEGEND WALL LEGEND o co Q <c` (y)O Q ❑ Cy)r — O O O O = 9'-4" T.O.M. = INTERIOR/EXTERIOR O BEARING WALL (OR LINTEL E' 11'-4" T.O.M. IF REFERENCED ON SHEET W S4). VERIFY HEIGHT W/ T_ = KNEE WALL TOP ARCHITECTURAL PLANS tL U.N.O. O N O EXTERIOR FRAME WALL ° oca SCHEDULE 1 (PARK SQUARE) D Q (a) WALLS WITH PLASTER OR STUCCO FINISHES = o Uj o WALL HEIGHT STUD & SPECIES SPACING SPACING p r v INTERIOR ZONE END ZONE 7 ds O 8'-0" 2x4 SPF #1/#2 16" O.C. MAX 16" O.C. MAX = 0 U) z O 1— > Q ❑ 9'-0" 2x4 SPF #1/#2 16" O.C. MAX 16" O.C. MAX W w ❑ W Z 9'-4" 2x4 SPF #1/#2 16" O.G. MAX 16" O.C. MAX w a o W IL W WU ❑ a 10'-0" 2x4 SPF #1/#2 16" O.C. MAX 12" O.C. MAX O C U) EXTERIOR FRAME WALL NOTES zz W 1. 2x4 WALL STUDS WITHIN 5 FT OF EACH CORNER ARE CONSIDERED TO BE WITHIN THE WALL END ZONE. SEE CHART ABOVE FOR W REQUIRED STUD SPACING. a- w m <( 2. SEE DETAIL WF10/SD4 FOR REQUIRED WALL SHEATHING THICKNESS =4a��� �d��✓ a & NAILING PATTERN. LL 2.1. NOTE: CONTRACTOR TO TAKE CARE AND NOT OVER DRIVE p� ��®q°a4� °U0° Z NAILS. IF NAILS ARE OVERDRIVEN, THE ENTIRE SHEET OF v) `% d SHEATHING IS TO BE REMOVED AND REPLACED. IF MORE THAN z0 /o Uj 50 OF THE SHEATHING IS OVERDRIVEN, CONTACT EOR FOR °� `r•o.4r Q REVIEW OF EXTERIOR STUDS j ��cvJ� asp;�0- 3. IF WALL IS FRAMED WITH 2x6 STUDS OR LARGER, STUDS ARE TO BE 0 ����°kd°G� G� O MIN. SPF #1/#2 @ 16" O.C. U.N.O. ON FRAMING PLANS n 4. SYP #2 STUDS MAY BE SUBSTITUTED FOR SPF #1/#2 STUDS ONLY. 5. IF EXT. FRAME WALL IS NOT SUPPORTING PLASTER OR STUCCO FINISHES, FRAMER IS TO FOLLOW CHART ABOVE U.N.O. Q r l � z �J ° 1— W • ULTIMATE WIND SPEED: 140 MPH EXPOSURE: B 0 0 0 0�C�J` Q w STANDARD 2ND FLOOR FRAMING - OT NOTES: z CD N U CC O z o q O 1. ALL EXTERIOR WALLS, LESS OPENINGS, ARE CONSIDERED SHEAR U :,., z WALLS. U.N.O. ATTACH SHEATHING PER NAILING SCHEDULE. O 0 S�Gv —i W H a `� 2. AT ALL WINDOW/ DOOR OPENINGS @ 2ND FLOOR, CONTRACTOR = TO FOLLOW THE DETAILS INDICATED BELOW: 1` w • �Sw� �, OPENING SITTING ON MASONRY- WS06/SD5 (STRAPS/BASE � ❑ O CONNECTIONS SHOWN ARE ONLY REQUIRED WHEN CALLED OUT 0 ON PLANS OR SHEATHING IS NOT CONTINUOUS) W (D r OPENING SITTING ON WOOD BEAM- WS07/SD5 (STRAPS U Z SHOWN ARE ONLY REQUIRED WHEN CALLED OUT ON PLANS OR Q ❑ SHEATHING IS NOT CONTINUOUS) W ❑ Z O m 0 3. AT ALL CORNERS, CONTRACTOR TO FOLLOW WS09/SD5 U.N.O. U Z5U r o Q W r z <O w m E 06 W Z U) J r O W ❑ 1— z . IL 6' a O z01—❑0W � r� F— �NWz� c z U)❑zX2Wiu o Z F- O O�� 0T_ E ❑ o < QEF- x N ~ Z ° W N Q W -� 75 F- �— l--- O W O 00,0 0 w z Z ❑ , �3 W �w� ® W W 3:®(l) U �� Q �W(L w =j ❑ �' �. U) U ® g � W � � T � <®:� CL N BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: -DESIGN: --- w��DINC-STRUCT: Jy QC CHECK: MRB SANFORD - a JOB No. PSQ-2171526 10FPARI��' SCALE: AS INDICATED ROOF FRAMING PLAN DATE: 08/2/20'17 1/4"=1 1-011 COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited.