Loading...
HomeMy WebLinkAbout110 Tech Dr 17-843; Spray boothCITY OF SANFORD BUILDING & FIRE PREVENTION 4 MAR 2 2017 _j r. PERMIT APPLICATION Application N - c � Documented Constructiont Job Address: 110 —\tc%; DoEHistoric District: Yes ❑ No ❑ . Parcel ID: Z7' \ - 30 C00a - 0310 Residential ❑ Commercial [� Type of Work: New ❑ Addition 9 Alteration --epair ❑ Demo ❑ Chgige of Use ❑ Move ❑ Description of Work: 5 'Ay 4A r'Mrr�t�nlinrF tr-- l U 7 Plan Review Contact Person: Tile: �Rcst�r Phone: Li 0'- -gL11• -1y0 Fax: rv[1-.V,.iso"3GC,Co1VX Property Owner Information Name &, '%'e Twice CICS" Q&3UE woo-bwot.V–s t_t_c_ Phone: �61-�`I�' Street: 110 T�ct� �e �u e Resident of property? : UES City, State Zip: Sa�yoe�S:) Contractor Information Name iA�So� Cc u s`iRv c`T to+� T �>, c . Phone: Street: S QANbr v>�JD . Fax: t- LA City, State Zip: 11N e ?WW2 , F� 32qct-. State License No.: CGC_ I SZ 9J\ Architect/Engineer Information Name: JAeolzj P1A Phone: 3z) - 2q:1 -)?Z) Street: OHC) 'S 09u*)-Ajo Ph E. 3-)l Fax: tJ A City, St, Zip: Fl, 33.3•5:l E-mail: Akj-4+tr�t:T. co— Bonding Company Address: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY tZFSUL'I' IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUSTBE RECORDED AND POS'T'ED ON THE JOB SITE BEFORE THE FfftST INSPECTION. IF :'OU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN AT"T"ORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51h Edition (2014) Florida Building Code Revised: lune 30, 2015 Permit Application 17-F43 �a) PLOT PLAN: Addition of Spray Booth to 1 10 Tech Drive Sanford Florida 32771 ABBREVIATIONS: EWC EXIT Electric g water cooler Existir N North E Q J - O NA Not applicable N FIN Firish NIG Not in contract A/C Air corditioring FLR Floor NO. Number A/E Architect/ Engineer FT Foot or feet NTS Not to scale AFF Above firish floor O.G. Or Center AHU Air handliro unit ALT Alternate GL G T F' SD C-tlasgse Gypsum Soard PL T WD Plywood CLCD Ceilirg `TD `STD Painted CMU Concrete masorry unit HTC. HMD Night Hollow metal door Rr( Room GPT C LU GT Ceramicaet Mile Hi" IF Hollow metal frame Q NVAG Heatirg, Vertilatirg S.F. Square feet DET Detail and air corditionir g 5TRUG7 Structural DIA DWG Diameter Drawing JAN Janitor TN;K Thickness T*T'P Typical EA Each LAV Lavatory EQUIP Equipment UNFIN Unfinished MAX Maximum 1"1ECH 1'lecharical WD Wood 1 1IN l"lirimum EXTERIOR PRSPECTIVE: CODE INFORMATION: JUl`'ISDICT10N CITY OF S NFOfRD 300 N. mark ,4 venue Sanford, Florida 32-1-11 ,4D01=7ED GODES wilding Code Florida wilding Code 0=5G) 2014 - nth Edition Electrical GodeNF ,4 2011 NEC ,4GGc�SSlblllty Florida 5uilding Code 0=55) 2014 - nth Edition 5UILDING GO ,5T1RUGTION DATA Occupation Classification Factory (T-15) Gonstruction Type 115 - Sprinkled Cexistincj Existing 5uilding ,4rea &E0 ,28ro s.f. Parcel ID: 28-19-30-�� b-0000-0310 SCOPE OF WORK: Addition of a Spray 5ooth to the facility. NOTES AND REQUIREMENTS: 1. ,411 work to comply with the FSG and all other applicable rules and regulations. 2. These construction documents are the property of the architect and shall not be used or reproduced in any form without the expressed written permission of the architect. 3. The Contractor shall verify all conditions before proceeding with the work. and shall be responsible for coordinating the same. Architect shall be notified of any discrepancies. 4. It is intended that all work be first quality and accomplished in a workman manor by skilled craftsman usirg accepted practices and methods appropriate to trades involved. �. All products and materials shall be in- stalled per manufacturer's guidance and specifications. MAR 2 8 20V 3 �a BY. - INDEX OF DRAWINGS: PERMIT ID Name A -O COVER SHEET A -i FLOOR PLAN A-2 SPRA" BOOTH INFORr',4TION REVIEWED FOR C COMPLIANCE J��aINc plp, EXAMINER DATE NFOR SANFORD_ BUILDING DIVISION A PEPP,,IIT ISSUED SHALL BF CONS i ,RUED TO BE A LICEN E TO Pp.ocEF.D WITH TF. I'1/ORK AND NOT AS AU T N()R!' v 'ro VIOLATE, CANCEL. ALTER OR SET ASIDE: ANY OF THE PROVISIONS OF THE TE04JI I-ICAL CODES, NOR SI4ALL !SSl IANCE OF A PERMIT PREVE1,.T TI -IE 80LDING O) F -I IAL FROM THEREAFTER REOiJIPlINIG A �;OR4ECIfON •:!F t'+Rl%IN PIANS, CONSTRUC-(ION OR VIOLt,[IONS OF THIS CODE 5P � nEPAi OFFICE F� Z '.1v_ E Q J - O N Z M O _ ci �ziZ) Ln O � C Henry R. Wolf - AR 7825 Pri rated PERMIT SET February 13, 201 Project No.: 1701 Drawn by: Wolf Checked by: Wolf COVER SHEET A-0 N Z M O _ O Ln O O L O � > LU J Q Pri rated PERMIT SET February 13, 201 Project No.: 1701 Drawn by: Wolf Checked by: Wolf COVER SHEET A-0 A&. 0 NOTESO L AIDF-) new spray booth. 2. NECHANICAL - No chane( --e No charges. 4., SFi�INKLEF, S' ' -STEM - No c-hanees. No exterior site chances. ------- .......... . Henry R Wolf - AR 7825 0 < z Lu 0 < 4-j 0 N 43 ID LU GQ LL' rd ywq c>1 (D 14— ------- .......... . Henry R Wolf - AR 7825 Printed TfERMIT SET February 13, 201-1 Project No.: 1701 Drawn by: w0IF Checked by: W01F FLOOR PLAN A-1 z 0 4-j 0 GQ LL' c>1 (D 14— z 0 < > —u C) Printed TfERMIT SET February 13, 201-1 Project No.: 1701 Drawn by: w0IF Checked by: W01F FLOOR PLAN A-1 Henry R. Wolf - AR 7825 Printed PERI" 11T SET Rsbruary 13, 2011 Project No.: 1701 Drawn by: l.Uolf Checked by: Wolf SPRAY BOOTH INFORMATION A-2 r. z 0 J_- O -� o C LL .0 cn LSI Q CD Printed PERI" 11T SET Rsbruary 13, 2011 Project No.: 1701 Drawn by: l.Uolf Checked by: Wolf SPRAY BOOTH INFORMATION A-2 A r B ■ C ■ D ■ E ■ ■ Fi ■ K l 2 3 ■ 4 ■ 5 6 7 $ r 9 ■ 10 ■ 11 ■ 12 ■ 13 " 14 ■ 15 SECTION 15010 - GENERAL MECHANICAL PROVISIONS SECTION 15010 - GENERAL MECHANICAL PROVISIONS (CONT). SECTION 15890 - DUCTWORE-ANU Q ZC,TWQRK ACC SES ORIES (CONT), PART 1 - GENERAL E, The Contractor will be expected to furnish materials and equipment rom tl after award of contract, and 3.02 DUCTWORK SERVICE SCHEDULE r� Ppromptly shall proceed with his work without delay, and shall agree to perform and complete all of his work in progress 1.01 RELATED DOCUMENTS with the work of other Contractors engaged on the project. A. Galvanized Steel: exhaust Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 e Specification Sections, apply to this and the other sections of Division 15. 3.02 VISITING SITE 3.03 SHEET METAL DUCTWORK The Contractors shall visit the site and carefully examine the premises and thoroughly familiarize themselves as to 1.02 SCOPE OF WORK the nature and scope of work and the difficulties that attend its execution. The submission of a Proposal will be A. The Contractor shall furnish and install all ductwork required in connection with the Air Distribution and 0. The work of this Section consists of all labor, materials, equipment, transportation, and facilities necessary to construed as evidence that such an examination has been made and later claims for labor, equipment or material Exhaust Systems. F provide a complete and satisfactory system ready to use. Whenever the words "the Contractor" appear in this required, or of difficulties encountered will not be recognized. Division, they refer to the Contractor for work specified in that section. The Contractor shall examine ALL Drawings B. All sheetmetal ductwork shall be constructed and installed, as a minimum, in .accordance with SMACNA and ALL sections of the Specifications and shall be responsible for ascertaining to what extent other drawings and 3.03 MEASUREMENTS manual titled "HVAC Duct Construction Standards - Metal and Flexible". B UHOLTZ PROFESSIONAL sections affect the work herein specified. Contractors shall take their own measurements at the beginning and shall be responsible for the correctness of and proper fitting of their work. Adjust all work to fit actual job conditions. Report to the Engineer all C. The internal dimension of all ducts shall be of size indicated on the drawings. In no case shall the ENGINEERING INC. 1.03 CODES AND STANDARDS measurement discrepancies, so that field corrections can be made before fabrication of project components, jQ Contractor change the indicted size of the ductwork without written approval of the Engineer, not scale the drawing. A. All work must be performed in accordance with the requirements of all pertinent Federal and State codes; D. The Contractor shall carefully check the arrangement of ducts and dimensions of all working spaces at 154 Tuskawilla Rd., Ste. 1380 Winter Springs FL 32708 but if in contradiction to the plans or the specifications, the proposed changes must first be referred to the END 15010 the building so that there will be no interference with the running of ducts. The Contractor shall carefully lay out Ph 407-327-3300 Engineer for review and approval. Base bid shall include the more stringent of the contradicting methods. all openings in roof. CA 00009600 SECTION 1505Q -BASIC MECHANICAL MATERIALS AND METHODS B. All work shall comply with the latest edition of the Florida Building Code (all applicable sections and E. All ductwork shall be securely supported and shall be installed so as not to interfere with plumbing, piping divisions). PART 1 - GENERAL and lighting. THESE PLANS AND DESIGNS SHOWN HEREON C. All equipment, apparatus and systems shall be rated, tested, fabricated and/or installed in accord with the 1.01 DESCRIPTION OF WORK J. Where shown on the drawings, provide duct -mounted access panels (doors). Panel size shall be sufficient REMAIN THE PROPERTY 0 F B U H 0 LT Z applicable industry standard. This Section includes basic mechanical materials and methods to complement other Division 15 Sections. for access to accommodate required servicing. The panels shall be a standard product of a company engaged in PROFESSIONAL ENGINEERING, INC. THEIR USE the manufacturing of access panels and shall be complete with frame, insulated door, gasket(s) and latches. WITHOUT WRITTEN LICENSE IS PROHIBITED. 1.04 PERMITS AND FEES: The Contractor and/or subcontractors shall be required to obtain building permits 1.02 QUALITY ASSURANCE COPYRIGHT B U H O L T Z PROFESSIONAL for the project. Where inspections of the work are required by local authorities, the Contractor shall obtain Furnish proof of the competency of each welding operator, for both field and shop welds, and have all welding 3.04 SEALING DUCTS ENGINEERING, INC. ALL RIGHTS RESERVED certificates of inspections of his work by such authorities, and these certificates (in triplicate) shall be submitted operators pass a standard qualification test such as A,S.M.E., A.W.S. or Hartford Insurance Company procedure and to the Engineer before final certificate for payment under his contract will be issued. tests. A. As a minimum, seal all lateral and longitudinal joints in all ducts according to SMACNA Seal Class A unless otherwise noted on drawings or specified herein. 1.05 SUBMITTALS 1,03 SUBMITTALS Provide in accord with Section 15010, for all products governed by this section to be utilized on this project. B. Lock all seams in ductwork and hammer flat; make absolutely tight against air leakage. Lap joints with A. After receiving approval of material and equipment manufacturers, and prior to delivery of any material or inside lap in direction of air travel. Install sufficient slip joints in the ducts to take care of expansion and equipment to job site, and sufficiently in advance to allow Engineer ample time for checking, submit for approval PART 2 - PRODUCTS contraction. six (6) copies each of detailed, dimensioned product submittals and drawings or cut sheets showing construction, size, arrangement, operating clearances, performance characteristics, and capacity of material and equipment. Not applicable. END 15890 Contractor shall allow a minimum of seven (7) days for review of each submittal by the Engineer. PART 3 - EXECUTION B. The Engineer's approval of such submittals shall not relieve this Contractor from responsibility for errors, �+� V J Alterations to construction made necessary by reason of approval action on materials or equipment shall be the 3.01 PAINTING responsibility of the Contractor and shall be made without additional cost to the Owner. A. Where factory finishes are provided on equipment, and no additional field painting is specified, all marred 1.06 COORDINATION OF WORK, AND COORDINATION / SHOP DRAWINGS or damaged surfaces shall be touched -up or refinished by the Contractor furnishing the equipment, so as to leave a smooth, uniform finish at the time of final inspection. Where steel equipment has been scratched as to O A. Each Contractor and subcontractor shall be responsible for coordinating the installation of his equipment expose the metal, a prime coot of rust -inhibitive primer shall be applied prior to final touch-up or refinishing. and work with the work of other trades. W B. All structural steel or other ferrous metal furnished by any Contractor which is not galvanized, either B, The layout shown on the Drawings is necessarily diagrammatic but shall be followed as closely as actual inside or outside of the building shall be cleaned of all grease, oil, dirt, loose scale, etc. and given a prime coot Q construction and as other work will permit. Changes from these Drawings required to make the work conform to of rust -inhibitive primer at the time of installation. All exposed structural steel or other ferrous metal outside of Z O the building construction or other work of other trades shall be made by the Contractor without additional cost to the building installed by a Contractor, not galvanized or specified to be painted under the Painting Section of the the Owner, but only with the prior approval of the Engineer, All major changes shall be shown on the shop specifications shall be given two additional coats of long oil type point with rust and corrosion -resistant qualities. OO F - drawings to be submitted before changes are made. O C. Equipment and structural steel, except where provided with a factory finish, shall be painted machine gray. C. The Contract Documents are design drawings, not fabrication and installation drawings. They are Nameplates are to be left unpainted, r , diagrammatic in nature and therefore do not indicate all offsets and fittings that may be necessary to complete the mechanical systems. The bidder is to assume, and include in his bid, all necessary transitions, offsets and END 15050 t'D U. fittings to complete the mechanical systems and shall indicate same in shop drawings. Q V,,,,,, SECTION 15890 --DUCTWORK AND DI�G]y�QRK ACCESSORIES 1.07 JOB CONDITIONS O Q 0 PART 1 -GENERAL A. Protection of Work: The Contractor shall protect his work from injury. Keep all pipes and lines capped Z W W or plugged, drained, or otherwise protected from injury, including damage done by flooding or stoppage from 1.01 SCOPE OF WORK: The work of this Section consists of all labor and materials necessary to provide all ^ a building materials or dirt. The Contractor shall protect equipment and fixtures furnished under his contract from ductwork and ductwork accessories, install temperature control dampers furnished by Controls Contractor, and z OL damage during the construction of the building and he shall provide all tarpaulins, drop cloths, barricades, providing required connections to equipment furnished under other sections of these specifications requiring exhaust v7 temporary heaters, auxiliary pumping equipment or other precautions as may be required, Any material or and ventilation. co equipment that is injured or damaged shall be removed immediately and replaced with new materials or J equipment. 1.02 QUALITY ASSURANCE MMO d B. Damage to Building: An damage to the building or its contents incurred b the installation and/or A. Manufacturers: Firms regularly engaged in manufacture of ductwork products of es, materials, and W 9 9 Y 9 9 Y / 9 YP YP testing of the systems installed under these contracts shall be repaired promptly. The Contractor shall provide sizes required, whose products have been in satisfactory use in similar service for not less than 5 years. Z L drop cloths, or any other material necessary to protect floors, walls, furniture, equipment, etc., from soil or O damage. B. Installer shall be a firm with at least 3 years of successful installation experience on low and/or medium ® Z pressure ductwork systems similar to that required for this project. cr) Q � C. Overloading of Building: Care shall be taken that floors and/or roof are not overloaded during buildingCc operations, and the Contractor shall promptly remove all materials, which may overload any part of the building. C. Codes and Standards: The Latest Edition of the following codes and standards apply to all or part of the nn products or procedures covered in this specification. Individual items of the specification may refer more 1.i. D. Removal of Rubbish: The Contractor shall at all times keep the premises free of all waste or surplus specifically to applicable sections of these codes or standards. As a minimum, all work shall comply with the materials, rubbish and debris, which is caused by his employees or resulting from his work. In case of dispute, applicable section(s) of each of the following: the Owner may remove the rubbish, excess materials, or do all cleaning required and charge the cost to the Z W Contractor. Adhesive and Sealant Council (ASC), American National Standards Institute (ANSI/ASTM). 1.08 WARRANTY American Society of Heating, Refrigerating and Air -Conditioning Engineers (ASHRAE). The warranty for all mechanical equipment (whether manufacturer's or contractor's warranty) shall comply with the Local and State regulations. requirements noted in the General Conditions and within each specification section (or a minimum of 12 months National Fire Protection Association (NFPA). W parts and labor, whichever is greater). This equipment shall include all equipment provided under Division 15, Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA). J Standard Building Code, PART 2 - PRODUCTS Standard Mechanical Code. Thermal Insulation Manufacturers Association (TIMA). 2.01 MATERIALS Underwriters Laboratories (UL). Materials and equipment shall be new, unless otherwise specified, and the best of their respective kinds. Florida Energy Code, 2.02 SUBSTITUTIONS 1.03 SUBMITTALS: Provide in accordance with 15010, for all products governed by this section to be utilized on this project. Also provide Shop Drawings for ductwork and fittings, and mechanical room layouts. A. Certain materials and equipment are specified by manufacturers or trade name and catalog or model number to establish standards of quality and performance, not for the purpose of limiting competition. 1.04 PRODUCT HANDLING B. Where an item of material or equipment is specified to be a certain manufacturer's make with other A. Protect ductwork, accessories and purchased products from damage during shipping, storage and handling. manufacturers names specifically mentioned, the Base Bid proposal shall include comparable material or equipment Ductwork shall not be stored outdoors. from one of those so specified. SEAL i � ► � � � � � �� B. Ductwork, stored or installed, found to be damaged as a result of moisture, vandalism, carelessness or C. Should the Contractor desire to receive consideration of equipment or materials other than as specified, construction traffic shall be replaced in new condition by the Contractor, to the satisfaction of the Owner and at r i he shall make such proposals in writing at the time of bidding, submitting therewith a statement of the extra or no additional expense. There will be no exceptions. credit involved, if any, in the event the proposed substitution is accepted. �• f'� 1.05 QUALITY ASSURANCE PROCEDURE - DUCT SYSTEMS • 5797 D. It shall be the Contractors responsibility to present sufficient data, including samples if requested, to show why he considers the proposed substitution to be equal in quality and type to that specified. A. Stored ductwork shall be sealed with Visqueen on each end of each piece of duct and shall be covered • ` with Visqueen at all times during storage periods to keep dust from entering the ductwork system. a TATE OF * ` E. It shall be each Contractor's responsibility to ascertain that alternate manufacturers products meet °� '•., O . • tz Act- detailed detailed specifications and that size and arrangement of equipment is suitable for installation. B. Prior to installation, Contractor shall inspect the ductwork and wipe the inside surfaces of duct clean. 'r�?C• Rti �"•aw��` F. It shall be the responsibility of each Contractor making a substitution to include any changes required by C. Upon installation of each section of the ductwork, all outlets shall be covered with Visqueen and taped ®I'll U� 141,0E the other trades for a proper operation of the equipment substituted. shut to keep construction dust from entering the ductwork once it is installed. This procedure shall be carried CAC57V9 979 out the some day the ductwork is installed. Duct joints shall be sealed as soon as possible. G, All proposed substitutions will be reviewed by the Owner. Any substitutions which are accepted will be handled by a properly written Change Order after award of Contract and unless so set forth no proposed D, Ductwork shall be periodically checked by Contractor during course of construction to insure that protective REVISIONS substitutions will be considered to have been accepted. Visqueen remains sealed around all openings of the ductwork. PART 3 - EXECUTION E. After completion of installation, the interior walls of ductwork shall be inspected for dirt and dust by REV # DATE DESCRIPTION Contractor, Architect, Engineer and Owner. If unacceptable amounts of dust and dirt are visible, the ductwork Al - - 3.01 GENERAL REQUIREMENTS shall be professionally cleaned at no additional cost to the Owner. A. The Contractor shall keep informed as to the Work of the trades engaged in the construction project, and PART 2 - PRODUCTS other work being done in connection with the building, and shall execute his work in such a manner as not to Q - - interfere with or delay other Contractors. 2.01 DUCTWORK ® - - B. The Contractor shall employ a competent foreman on the job throughout the entire period of construction A. Galvanized Sheet Metal: to see that his work will not conflict with other work or trades, and that it is properly performed. The foreman ASTM A653, Lock -forming Quality, Coating G-90 (0.90 oz./S.F.), The weight of steel used shall not be less than Q - - shall have a thorough knowledge of the work to be installed under this Contract and be a skilled mechanic is listed in the SMACNA manual "HVAC Duct Construction Standards", Latest Edition. See SMACNA manual for gage- - experienced with projects of equal size and type. and reinforcement requirements and provide all aQs required, Minimum operating static pressure is as follows: 6 C. Workmanship throughout shall correspond to the standard of best practice, and all labor employed must Exhaust: V-2.0" 0 - be competent and do the work required. Tool marks will not be permitted on any exposed materials, fittings or ® - - piping. 2.02 ACCESS PANELS: Frame shall be minimum 22 go, galvanized steel with seal. Door shall be non -hinged type with cam latches. Gasket on frame and door shall be neoprene or foam rubber, Latches shall - - D, The Drawings accompanying these Specifications ore design drawings and generally are diagrammatic. be zinc plated. Access panel construction shall provide airtightness suitable for the pressure class of the duct. They do not show every offset, bend or elbow which may be required in the contract work for installation in the DATE 03.16.17 space allotted. The Contractor shall follow the Drawings as closely as practical and he shall install additional bends PART 3 - EXEQUTION and offsets based upon measurements taken at the building, as may be required for installation of the work. DRAWN BY M.J.B. Changes from these Drawings required to make this work conform to the Building construction work of other 3.01 DUCTWORK AND MECHANICAL ROOM SHOP DRAWINGS trades shall be made by this Contractor without additional cost to the Owner, but only with the prior approval of DESIGNED BY M.J.B. the Engineer. All major changes shall be shown on Shop Drawings to be submitted before the changes are made. A. The Contract Documents are design drawings, not fabrication and installation drawings. They are APPROVED BY B.T.B. diagrammatic in nature and therefore do not indicate all offsets and fittings that may be necessary to complete the ductwork systems. The bidder is to assume, and include in his bid, all necessary transitions, offsets and PROJECT NUMBER 17119-00 fittings to complete the duct systems and shall indicate some in ductwork shop drawing package. 1 2 3 4 ■ 5 0 6 IN 7 r 8 0 9 ■ 10 0 11 0 12 ■ 13 11 14 ■ 1t) ■ DRAWING M-1 A ■ ■ F ■ G ■ FI ■ J K A 1 r r 3 ■ 4 r 5 ■ 6 ■ I ■ 8 ■ 9 ■ 10 11 12 13 14 ■ 15 ■ W ■ Rl s w c ■ ■ ■ I I ■ 1 2 ■ 3 w 4 5 ■ 6 7 ■ a 9 ■ 10 ■ 1"I 12 ■ 13 ■ 14 15 ■ .f c N , r I I ■ 1 2 ■ 3 w 4 5 ■ 6 7 ■ a 9 ■ 10 ■ 1"I 12 ■ 13 ■ 14 15 ■ .f A ■ JI E B _ J 1 ■ 2 ■ 3 ■ 4 ■ 5 ■ 6 7 8 9 ■ 10 ■ 11 ■ 12 ■ 13 ■ 14 ■ 15 ■ A ■ JI E B ■ C ■ D ■ F ■ G H E _ J F ■ G H K ELECTRICAL SPECIFICATIONS GENERAL NOTES GENERAL WIRE AND CABLE PANEL BOARDS 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2014 N.E.C., F.B.C. 2014 AND ANY OTHER APPLICABLE STATE 26, SPECIFICATIONS: BECOME FAMILIAR WITH ALL SPECIFICATIONS, DESIGN CRITERIA, AND EQUIPMENT AND LOCAL REQUIREMENTS, REQUIREMENTS PRIOR TO ANY EQUIPMENT PURCHASE OR INSTALLATION. REFERENCE SPECIFICATIONS FOR DEVICES, 1. ALL WORK PERFORMED AND MATERIALS PROVIDED SHALL CONFORM TO THE 2014 1. ALL WIRE SHALL BE COPPER WITH INSULATED RATED AT 600 VOLTS, 75 DEGREES 1. FURNISH AND INSTALL ALL PANELS SHOWN ON THE DRAWINGS, PANELS MUST MATERIALS AND WORKMANSHIP REQUIREMENTS. ADDITIONAL REQUIREMENTS ARE GIVEN IN THESE NOTES AND THE NATIONAL ELECTRICAL CODE (NEC) AND ALL OTHER APPLICABLE STANDARDS, CODES CELSIUS MINIMUM UNLESS OTHERWISE NOTED. MATCH EXISTING MANUFACTURER, THIS EQUIPMENT SHALL BE FACTORY ASSEMBLED 2. THE DRAWINGS ARE DIAGRAMMATIC AND THE OMISSION OF AN ITEM NECESSARY FOR THE PROPER FUNCTIONING DRAWINGS. THERE SHALL BE NO DEVIATION FROM SPECIFICATIONS WITHOUT THE WRITTEN APPROVAL OF THE AND LAWS. THE EDITION OR YEAR -DATE FOR ALL CODES AND STANDARDS SHALL BE UNIT ONLY. ON THE SYSTEM DOES NOT RELIEVE THE ELECTRICAL CONTRACTOR FROM SUPPLYING THAT ITEM, ENGINEER. THAT CURRENTLY ADOPTED BY THE MUNICIPALITY OR OTHER LOCAL AUTHORITY HAVING 2. MINIMUM WIRE SIZES SHALL BE #12 FOR POWER WIRING. JURISDICTION. 2. PANEL BOARDS SHALL BE PAINTED WITH GRAY LACQUER RUST PREVENTATIVE 3. THE DESIGN IS BASED ON THHW/THHN COPPER CONDUCTORS, 27. COORDINATION: COORDINATE WORK WITH ALL OTHER TRADES, GIVE SPECIAL CONSIDERATION TO 3. WIRE SHALL BE SOLID TYPE OR THHN/THWN UP TO SIZE 10 AWG AND STRANDED PRIMER. SIDES AND TOP OF SURFACE MOUNTED PANELS SHALL BE PAINTED TO MATCH COORDINATING INSTALLATION OF LIGHTING, SPRINKLER PIPING, AND DUCTWORK. COORDINATE WALL OUTLET 2. COORDINATE ALL ELECTRICAL WORK WITH THAT OF OTHER TRADES, TYPE THWN OR XHHW FOR SIZE 8 AWG AND LARGER (UNLESS OTHERWISE NOTED). FRONTS, 4. ALL EXIT AND EMERGENCY LIGHTS SHALL BE CONNECTED TO THE UNSWITCHED LEG OF THE LOCAL LIGHTING LOCATIONS WITH MILLWORK. COORDINATE WALL SWITCHES WITH DOOR SWINGS. VERIFY EXACT LOCATION, COLOR CIRCUIT. AND FINISH OF OUTLETS AND DEVICES WITH INTERIOR DESIGNER, ARCHITECT, OR DESIGNATED TENANT B UHOLTZ PROFESSIONAL 3. INSPECTION: PRIOR TO ALL WORK OF THIS SECTION, CAREFULLY INSPECT THE 4, TERMINAL LUGS SHALL BE MECHANICAL CLAMP OR COMPRESSION TYPE UNLESS 3. PANELS SHALL BE OF THE CIRCUIT BREAKER TYPE UNLESS OTHERWISE NOTED AND REPRESENTATIVE PRIOR TO INSTALLATION. INSTALLED WORK OF ALL OTHER TRADES AND VERIFY THAT ALL SUCH WORK IS PART OF A CIRCUIT BREAKER OR SWITCH ASSEMBLY. SET SCREW TYPE LUGS IN WHICH SHALL HAVE CAPACITY AND ARRANGEMENT AS SHOWN ON THE PANEL SCHEDULES OR 5, THE LOCATION AND SIZE OF LOADS SHALL BE CHECKED WITH THE OWNER, ARCHITECT OR APPROPRIATE COMPLETE TO THE POINT WHERE THIS INSTALLATION MAY PROPERLY COMMENCE. THE SET SCREW BEARS DIRECTLY ON THE CONDUCTOR SHALL NOT BE USED, ONE -LINE DIAGRAM. SUBCONTRACTOR AND ADJUSTMENTS MADE ACCORDINGLY. 28, PRODUCTS: ALL PRODUCTS SHALL BE NEW, SPECIFICATION GRADE. PRODUCTS OF A SIMILAR NATURE SHALL ENGINEERING, INC. BE OF THE SAME TYPE AND MANUFACTURER, PROVIDE THE STANDARD PRODUCTS OF MANUFACTURERS REGULARLY 154 Tuskawilla Rd., Ste. 1380 Winter Springs FL 32708 4. INTERFERENCE: AVOID INTERFERENCE WITH STRUCTURE AND WITH WORK OF OTHER 5. UNDER NO CIRCUMSTANCES SHALL FEEDERS BE SPLICED. 4, BRANCH CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE AND SHALL BE OF THE 6. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR LOCATION OF ALL EXISTING UTILITIES IN THE VICINITY OF ENGAGED IN THE PRODUCTION OF SPECIFIED PRODUCTS, UNLESS OTHERWISE REQUIRED BY DRAWINGS. ALL TRADES, PRESERVING ADEQUATE HEADROOM AND CLEARING ALL DOORS AND AMBIENT COMPENSATED, THERMAL MAGNETIC TYPE, WHICH WILL PROVIDE INVERSE TIME CONSTRUCTION AND SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGES HE CAUSES. PRODUCTS SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH NATIONALLY RECOGNIZED AND Ph 407-327-3300 PASSAGEWAYS. 6. COLOR CODE THE ENTIRE POWER WIRING SYSTEM IN ACCORDANCE WITH THE DELAY OVERLOAD AND INSTANTANEOUS SHORT CIRCUIT PROTECTION. VOLTAGE AND ACCEPTED STANDARDS AND PROCEDURES, CA 00009600 NATIONAL ELECTRICAL CODE, AND ALL STATE AND LOCAL CODES. CURRENT RATINGS SHALL BE AS INDICATED ON THE DRAWINGS, 7. COORDINATE ALL ELECTRICAL WORK WITH THAT OF OTHER TRADES PRIOR TO THE INSTALLATION OF THAT WORK. F LOCATIONS LL EXISTING UTILITIES. 30. COMPATIBILITY: ALL NEW 5. THE CONTRACTOR SHALL CONFIRM THEOF W ELECTRICAL DISTRIBUTION EQUIPMENT SHALL MATCH AND BE COMPATIBLE WITH THESE PLANS AND DESIGNS SHOWN HEREON CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING UTILITIES TO 7. PROVIDE A COMPLETE CONTROL WIRING SYSTEM FOR ALL ELECTRICAL EQUIPMENT 5. PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH PANEL, PLACED INSIDE THE PANEL 8. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL INSPECTIONS, ALL CERTIFICATES, AND PERMITS REQUIRED, EXISTING EQUIPMENT, BY MANUFACTURER TYPE, APPLICATION, AND SHORT CIRCUIT RATING. REMAIN THE PROPERTY 0 B U 0 DOOR. DIRECTORIES SHALL BE INSTALLED IN A METAL DIRECTORY FRAME WITH CLEAR INCLUDING ALL ASSOCIATED FEES BY THE LOCAL CODE ENFORCEMENT AGENCY. F H LTE THE BUILDING. AND APPLIANCES, INCLUDING ALL OWNER -FURNISHED EQUIPMENT. EQUIPMENT PROFESSIONAL ENGINEERING, INC. THEIR USE FURNISHED UNDER OTHER DIVISIONS MECHANICAL EQUIPMENT, ETC. SHALL BE PROTECTIVE COVER. SPARES AND SPACES SHALL BE NOTED. 31. IDENTIFICATION: ALL ELECTRICAL DISTRIBUTION EQUIPMENT, TRANSFORMERS, PANELBOARDS AND OTHER 6. BEFORE ORDERING ANY MATERIALS OR EQUIPMENT, THE CONTRACTOR SHALL SUBMIT ( ) 9. THESE DRAWINGS AND PROJECT MANUAL ARE COMPLIMENTARY. IT IS THE CONTRACTORS RESPONSIBILITY TO ENCLOSED EQUIPMENT SHALL BE IDENTIFIED AS INDICATED IN THE CONTRACT DOCUMENTS. SAID IDENTIFICATION WITHOUT WRITTEN LICENSE IS PROHIBITED. PROPERLY INSTALLED WITH ELECTRICAL CIRCUITS AND CONNECTIONS, DISCONNECTS, COPYRIGHT B U H O L T Z PROFESSIONAL SHALL CONSIST OF PERMANENTLY ATTACHED ENGRAVED LAMINATED PLASTIC NAMEPLATES. EACH BRANCH ENGINEERING DATA FOR ALL MATERIALS AND EQUIPMENT HE PROPOSES TO USE AND STARTERS, OPERATOR CONTROL PUSH -BUTTONS, ALARMS, ETC, AS SPECIFIED FOR 6. EACH PANEL SHALL BE EQUIPPED WITH A GROUND LUG/BUS. EXAMINE THE DRAWINGS AND SPECIFICATIONS AND TO COMPARE THE REQUIREMENTS OF EACH DIVISION (i.e. ENGINEERING, INC. ALL RIGHTS RESERVED FURNISH. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING EQUIPMENT EACH TYPE OF ITEM. ELECTRICAL, ETC.) AND ENSURE THAT EACH TRADE OR SUBCONTRACTOR IS MAKING THE ALLOWANCES NECESSARY CIRCUIT OVERCURRENT PROTECTION DEVICE SHALL BE IDENTIFIED BY CIRCUIT NUMBER AND SCHEDULED INSIDE DIMENSIONS OF PROPOSED SUBSTITUTE EQUIPMENT AND SHALL BE RESPONSIBLE FOR 7. EACH PANEL AND CABINET AND THE UNITS COMPRISING SAME SHALL BEAR THE TO PROVIDE THE OWNER A COMPLETE FACILITY OPERATIONAL IN ALL RESPECTS, UNLESS OTHERWISE SPECIFICALLY PANEL DOOR. EACH BRANCH CIRCUIT SPLICE OR TERMINATION SHALL BE IDENTIFIED BY PANEL AND CIRCUIT ITS FITTING IN THE SPACES ALLOWED. THE COST OF ANY REDESIGNING CAUSED BY A 8, ALL SWITCHES FOR CONTROLS, SIGNALS, PILOTS, REMOTE TRIP OPERATORS, MANUFACTURER'S NAMEPLATE AND THE UL LABEL. NOTED IN THE DRAWINGS, IT IS ALSO THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE ARCHITECT/ENGINEER OF DESIGNATION SHOWN ON THE JUNCTION OR OUTLET BOX, OR UPON INDIVIDUAL WIRES IN CASES WHERE MORE SUBSTITUTION SHALL BE BORNE BY THE CONTRACTOR. RAISE/LOWER SWITCHES, REMOTE START/STOP MOTOR CONTROL STATIONS, AND ANY ANY DEFICIENCIES OR DISCREPANCIES AMONG THE DIVISIONS OF THE DRAWINGS AND SPECIFICATIONS PRIOR TO THAN ONE OF EACH PHASE CONDUCTOR OCCUR, OTHER DEVICES THAT ARE REQUIRED BY THE SYSTEM SHALL BE PROVIDED AND 8. CIRCUIT BREAKERS SHALL BE MANUFACTURED BY THE MANUFACTURER OF THE THE BID DATE, NEITHER THE OWNER NOR ARCHITECT/ENGINEER WILL BE RESPONSIBLE FOR ANY DEFICIENCIES OR 7. ALL ELECTRICAL MATERIALS AND EQUIPMENT SHALL BE UL LISTED. ALL MATERIALS INSTALLED BY THE CONTRACTOR. PANEL BOARDS. THERE SHALL BE NO EXCEPTION TO THIS. DISCREPANCIES RAISED AFTER THE BID OPENING. ACCORDINGLY, IN LIGHT OF THESE OBLIGATIONS, THE 32, WIRING: ALL CONDUCTORS CARRYING GREATER THAN 50 VOLTS SHALL BE MINIMUM #12 AWG, SOLID, CU, AND EQUIPMENT SHALL BE NEW, NON -SECONDARY MARKET PRODUCTS. ANY ARCHITECT/ENGINEER IS OBLIGATED TO INTERPRET THE DRAWINGS AND SPECIFICATIONS IN A MANNER THAT WILL SOFT DRAWN OF 98% CONDUCTIVITY, UNLESS NOTED OTHERWISE, EQUIPMENT RECONDITIONED AND/OR RE -PACKAGED WITHOUT FACTORY AUTHORIZA11ON 9. GROUNDING CONDUCTORS: ALL GROUNDING ELECTRODE CONDUCTORS AND 9. MOUNT PANELS IN LOCATIONS SHOWN, MAKING SURE THAT CODE REQUIRED PROVIDE THE OWNER WITH A COMPLETE, FUNCTIONING FACILITY FOR THE BID PRICE. IS UNACCEPTABLE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSULATED COPPER (AS SPECIFIED CLEARANCES EXIST. 8. THIS CONTRACTOR SHALL DO ALL CUTTING, DRILLING AND PATCHING REQUIRED BY ABOVE) UNLESS INDICATED OTHERWISE. 10. IF PAINT IS DAMAGED DURING SHIPPING OR INSTALLATION, DAMAGED PORTION 10. ANY AND ALL DEVIATIONS FROM SPECIFIED PRODUCTS MUST BE APPROVED BY THE ENGINEER. �� HIS WORK. ALL REPAIRS TO FINISH SHALL MATCH THE EXISTING, LEAVING NO 10. BRANCH CIRCUITS MAY BE GROUPED IN SINGLE RACEWAYS AND SHARE A COMMON SHALL BE SANDED SMOOTH AND ENTIRE PANEL REPAINTED. 11. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE APPLICABLE STATE, FEDERAL AND LOCAL CODES. `co DISCERNIBLE SCARS. STRUCTURAL MEMBERS SHALL NOT BE CUT UNLESS APPROVED NEUTRAL PROVIDED THE FOLLOWING GUIDELINES ARE MET AND/OR UNLESS THE" ALL NECESSARY LICENSES AND PERMITS SHALL BE OBTAINED BY THE CONTRACTOR AT HIS EXPENSE UNLESS �'■ BY THE ARCHITECT. DRAWINGS INDICATE OTHERWISE. 11. LIGHTING CIRCUIT BREAKERS SHALL BE SWD RATED. PREVIOUSLY OBTAINED BY THE OWNER. 9. THE CONTRACTOR SHALL PROVIDE A ONE-YEAR GUARANTEE FOR ITEMS FURNISHED A. DEDICATED CIRCUITS: PROVIDE A NEUTRAL PER PHASE CONDUCTOR FOR ALL 12, THE EXISTENCE AND LOCATION OF EXISTING UTILITIES ARE NOT GUARANTEED AND SHALL BE INVESTIGATED O THAT SHALL COVER: DEDICATED CIRCUITS. PROVIDE DEDICATED HOMERUN RACEWAY FOR EACH DEDICATED AND VERIFIED IN THE FIELD BY THE CONTRACTOR BEFORE STARTING WORK. EXCAVATION IN THE VICINITY OF rrnn A: FAULTY OR INADEQUATE DESIGN BY CONTRACTOR. CIRCUIT WHEN INDICATED ON DRAWINGS. - EXISTING STRUCTURES AND UTILITIES SHALL BE CAREFULLY PERFORMED, BY HAND. THE CONTRACTOR SHALL BE VJ B: IMPROPER ASSEMBLY OR ERECTION. HELD RESPONSIBLE FOR ANY DAMAGES TO, AND FOR PROPER MAINTENANCE PROTECTION OF, EXISTING UTILITIES O Z C: DEFECTIVE WORKMANSHIP AND MATERIALS. B. SINGLE PHASE, THREE WIRE SYSTEMS: PROVIDE A NEUTRAL CONDUCTOR FOR GROUNDING AND STRUCTURES DURING THE CONSTRUCTION PROCESS. THE CONTRACTOR SHALL BE LIABLE FOR ANY COSTS O Z O 10, CONTRACTOR SHALL PROVIDE/INSTALL ALL ELECTRICAL SYSTEMS REQUIRED BY EACH GROUP OF TWO SEQUENCED LINE CONDUCTORS. ASSOCIATED WITH THE RELOCATION OF TELEPHONE OR GAS LINES BY THE UTILITY COMPANIES. O ...�.. THIS PROJECT. THIS INCLUDES ALL MISCELLANEOUS ITEMS AND ACCESSORIES REQUIRED 1. PROVIDE A COMPLETE EQUIPMENT SAFETY GROUND SYSTEM (GREEN WIRE GROUND) O FOR THE COMPLETE AND CORRECT OPERATION FOR THE ENTIRE SYSTEM, WHETHER OR 11. CONTRACTOR SHALL VERIFY EXACT DISTANCES FOR FEEDER AND BRANCH CIRCUITS FOR THE ENTIRE ELECTRICAL SYSTEM AS REQUIRED BY ARTICLE 250 OF THE NEC AND 13. THE CONTRACTOR SHALL PROVIDE SAFE, SUFFICIENT, AND PROPER FACILITIES AT ALL TIMES FOR THE NOT SUCH ITEMS ARE ILLUSTRATED IN THE PROJECT DOCUMENTS. AND MAKE ANY APPLICABLE ADJUSTMENTS TO THE WIRE SIZES FOR VOLTAGE DROP. AS SPECIFIED HEREIN. INSPECTION OF THE WORK BY THE OWNER, ARCHITECT, AND ALL APPROPRIATE GOVERNMENTAL AND REGULATORY PANEL FEEDERS SHALL HAVE LESS THAN 2% VOLTAGE DROP AND BRANCH CIRCUITS AGENCIES. SHALL HAVE LESS THAN 3% VOLTAGE DROP. 2. ALL GROUNDING WIRE; LUGS, JUMPERS AND BUS SHALL BE COPPER. O �- 14. UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS OR OTHERWISE INSTRUCTED BY THE ARCHITECT, 3, ALL FEEDER AND BRANCH CIRCUITS SHALL CONTAIN AN EQUIPMENT GROUND WIRE. ELECTRICAL OUTLETS SHALL HAVE THE FOLLOWING MOUNTING HEIGHTS, DIMENSIONS ARE TO CENTER OF BOX 1..` NO METAL CONDUIT OF ANY KIND OR LENGTH SHALL BE USED AS THE EQUIPMENT UNLESS OTHERWISE NOTED: Q 0 U DRAWINGS BOXES GROUNDING CONDUCTOR. ��nn 1. PROVIDE OUTLET BOXES FOR ALL SWITCHES FIXTURES, RECEPTACLES AND ALL # v� 1. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE, BUT SHOW VARIOUS COMPONENTS WALL SWITCHES4. EQUIPMENT GROUNDING CONDUCTORS AND STRAPS SHALL BE SIZED IN ACCORDANCE " Z U OF THE SYSTEMS APPROXIMATELY TO SCALE AND ATTEMPT TO INDICATE HOW THEY OTHER OUTLET DEVICES. WALL CONVENIENCE RECEPTACLES 16 AFF TO BOTTOM OF BOX Q �n cls ARE TO BE INTEGRATED WITH OTHER PARTS OF THE BUILDING. DETERMINE EXACT WITH NEC. REFER TO FEEDER SCHEDULES FOR GROUND WIRE REQUIREMENTS WHICH WALL TELEPHONE OUTLETS 16" AFF TO BOTTOM OF BOX O co O MAY BE EXCEED THE NEC. ALL EQUIPMENT GROUNDING CONDUCTORS SHALL BE LOCATIONS BY REVIEW OF EQUIPMENT MANUFACTURERS DATA, BY JOB SITE 2. JUNCTION AND PULL BOXES SHALL HAVE SCREW -ON COVERS OR LOCKING HINGED WALL OUTLETS FOR WALL MTD. TELEPHONE O r MEASUREMENTS, PROVIDED WITH GREEN INSULATION EQUIVALENT TO THE INSULATION ON THE * .....1 Z BY CHECKING THE REQUIREMENTS OF OTHER TRADES, AND BY COVERS. NEMA 1 BOXES SHALL BE USED INDOORS. NEMA 3R BOXES WITH THREADED ASSOCIATED PHASE CONDUCTORS. MANUAL FIRE ALARM PULL STATIONS REVIEWING ALL CONTRACT DOCUMENTS. THE SIZE OF ELECTRICAL EQUIPMENT INDICATED HUBS SHALL BE USED OUTDOORS. FIRE ALARM SPEAKER/HORN 1'-0" BELOW CEILING, OR IN CEILING, AS REQUIRED W = ON THE DRAWINGS MAY BE BASED ON THE DIMENSIONS OF A PARTICULARINTERIOR BELLS BUZZERS HORNS 1'-0" BELOW CEILING OR IN CEILING AS REQUIRED 5. THE EQUIPMENT GROUNDING SYSTEM SHALL BE INSTALLED SO THAT ALL METALLIC " Z MANUFACTURER. WHILE OTHER LISTED MANUFACTURERS MAY BE ACCEPTABLE IT IS THE 3, BOXES SHALL BE SIZED IN ACCORDANCE WITH NEC ARTICLE 370. STRUCTURES ENCLOSURES RACEWAYS JUNCTION BOXES OUTLET BOXES CABINETS SPECIAL PURPOSE WALL OUTLETS 16 AFF TO BOTTOM OF BOX (OR HIGHER AS REQUIRED 0 U RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE IF THE EQUIPMENT THAT MACHINE FRAMES AND PORTABLE EQUIPMENT FRAMES OPERATE CONTINUOUSLY AT TO SERVE EQUIPMENT) CONTRACTOR PROPOSES TO FURNISH WILL FIT IN THE SPACE. 4. INTERIOR BOXES SHALL BE ONE PIECE, GALVANIZED STEEL CONSTRUCTION, GROUND POTENTIAL AND PROVIDE A LOW IMPEDANCE PATH FOR GROUND FAULT PUSH BUTTONS Q SUITABLE/LISTED FOR INTENDED USE. PROVIDE PLASTER -RINGS WHERE REQUIRED. CURRENTS. THE SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE, ADA VISUAL ALARM 80" AFF TO BOTTOM OF LENS OR 6" BELOW CEILING, a:I- 2. THE DRAWINGS ARE NOT INTENDED TO SHOW EXACT LOCATIONS OF CONDUIT, WIRE, INSTALL "GANGED" BOXES WHERE DEVICES ARE INDICATED TO BE GROUPED. WHICHEVER IS LOWER. ENTIRE LENS TO BE WITHIN 1 OR TO INDICATE ALL WIRE TERMINATORS, CONNECTORS, CONDUIT FITTINGS, BOXES, OR 6. GROUNDING CONDUCTORS SHALL BE CONTINUOUS AND NO SPLICING SHALL BE 80" to 96" AFF + ra. 0 SUPPORTS, BUT RATHER TO INDICATE DISTRIBUTION, CIRCUITRY, AND CONTROL. 5. EXTERIOR BOXES SHALL BE ONE PIECE PVC "UV PROTECTED". ALLOWED, 7 V J W # TOP OF BOX SHALL BE 48" AFF MAX. FOR WHEELCHAIR L 3. THE VARIOUS PHASES OF WORK. THE WORK SHALL BE LAID OUT SO THAT IT WILL 6. ALL CONDUIT CONNECTORS AND ENTRY HUBS SHALL BE INSULATED OR HAVE 7. PROVIDE COPPER GROUND BUSSES ON WALLS WHERE INDICATED ON THE DRAWINGS FRONTAL APPROACH AND 54" AFF MAX. FOR SIDE J BE CONCEALED IN FURRED CHASES AND SUSPENDED CEILINGS, ETC., IN FINISHED INSULATED BUSHINGS, AND WHERE SPECIAL GROUNDING NEEDS WILL ARISE, REFERENCE DETAIL ON DRAWING APPROACH, VERIFY EXACT HEIGHT WITH ARCHITECT. W PORTIONS OF THE BUILDING, UNLESS SPECIFICALLY NOTED TO BE EXPOSED. WORK FOR GROUND BUS AND CONNECTION REQUIREMENTS. SHALL BE INSTALLED TO AVOID CRIPPLING OF STRUCTURAL MEMBERS. ALL EXPOSED AFF = ABOVE FINISHED FLOOR WORK SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO THE LINES OF THE 8. WHERE REQUIRED, EMT CONNECTORS OR FLEXIBLE CONDUIT FITTINGS SHALL BE AFG = ABOVE FINISHED GRADE W BUILDING UNLESS OTHERWISE NOTED. WIRING DEVICES BONDED USING A CONDUIT LOCKNUT, T&B SERIES #106 OR EQUIVALENT, UL LISTED, 4. WHEN THE MECHANICAL AND ELECTRICAL DRAWINGS DO NOT GIVE EXACT DETAILS 1. PROVIDE A COMPLETE SYSTEM OF WIRING DEVICES PROPERLY WIRED, INCLUDING A 15. UNLESS SPECIFICALLY INDICATED ON THE ELECTRICAL DRAWINGS, OUTLETS LOCATED AT COUNTERS AND AS THE THE ELEVATION OF PIPE, CONDUIT AND DUCTS, PHYSICALLY ARRANGE THE SOLID GROUNDING CONNECTION. CABINETS SHALL BE MOUNTED AS SHOWN ON ARCHITECTURAL DETAILS AND ELEVATIONS, OR AS DIRECTED BY SYSTEMS TO FIT IN THE SPACE AVAILABLE. SPACES SHALL BE PRIORITIZED AS ARCHITECT, REQUIRED TO ALLOW FOR PROPER GRADES OF THE SYSTEMS INVOLVED. 2. UNDERWRITERS LABORATORIES: PROVIDE WIRING DEVICES WHICH ARE LISTED AND IDENEEIC TI N( SS 16. COORDINATE MOUNTING HEIGHTS AND DETAILS OF ALL OUTLETS (POWER, SIGNAL, ETC.) WITH ARCHITECTURAL LABELED BY UL, CASEWORK DRAWINGS PRIOR TO DIVISION 16 ROUGH -IN. PROVIDE COORDINATION DRAWINGS IN ACCORDANCE WITH 3, NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION: WIRING DEVICES SHALL 1. COMPLY WITH GOVERNING REGULATIONS AND REQUESTS OF GOVERNING AUTHORITIES DIVISION 16 SPECIFICATIONS WHERE CONFLICTS EXIST. OBTAIN APPROVAL FROM ARCHITECT BEFORE ELECTRICAL COMPLY WITH APPLICABLE NEMA STANDARDS. FOR IDENTIFICATION OF ELECTRICAL WORK. ROUGH -IN WHEN CONFLICTS ARISE, 4. DEVICE COLOR: WHITE UNLESS OTHERWISE NOTED, 2. PROVIDE NAMEPLATES/LABELS FOR ITEMS WHERE INDICATED AND/OR DESCRIBED IN 17, REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF ALL HVAC AND PLUMBING EQUIPMENT AND EQUIPMENT THESE SPECIFICATIONS. ROUGH -IN REQUIREMENTS SEAL 5. ACCEPTABLE: THE FOLLOWING MANUFACTURERS WILL BE ACCEPTABLE PROVIDING r 1. THE CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE INSTALLATION OF ALL THEY MEET THE PROJECT SPECIFICATIONS: COPPER WIRING DEVICES, ARROW -HART, 3. ALL ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE LABELED. 18. CIRCUITING ®oma°° ��� ��/ EQUIPMENT SHOWN ON THE DRAWINGS. ALL MANUFACTURERS SPECIFICATIONS SHALL HUBBELL, LEVITON, LUTRON, WOODHEAD INDUSTRIES, A. BRANCH CIRCUITING IS SCHEMATIC IN NATURE AND IS INTENDED TO INDICATE CIRCUIT LOADING °��j:'�s BE FOLLOWED IN REGARDS TO THE INSTALLATION OF ALL EQUIPMENT. ANY SPECIAL 4. LABELS SHALL BE ENGRAVED PHENOLIC TAGS WITH MINIMUM .5" TEXT HEIGHT. AND CONTROL, NOT METHODS OF INSTALLATION. REFER TO SPECIFICATIONS FOR METHODS OF MANUFACTURER'S REQUIREMENTS NECESSARY FOR PROPER OR SAFE INSTALLATION OF 6. STANDARD CONVENIENCE OUTLET: 20A/125V/2 POLE/3 WIRE DUPLEX NEMA 5-20R. DYMO (OR EQUIVALENT) LABELS SHALL NOT BE USED, INSTALLATION AND MATERIALS. ' pg EQUIPMENT REGARDLESS OF WHETHER THE AFOREMENTIONED SPECIAL REQUIREMENTS DUPLEX RECEPTACLE, RECEPTACLE FACE SHALL BE HIGH -IMPACT RESISTANT. NYLON 5. COLOR CODE: ALL POWER EQUIPMENT- BLUE FIELD WITH WHITE LETTERS. ARE INDICATED ON THE DRAWINGS, SHALL BE AT THE EXPENSE AND RESPONSIBILITY BODY SHALL BE THERMOPLASTIC POLYESTER. MOUNTING STRAP SHALL WARP B. WHERE WIRE SIZE AND CONDUIT SIZE IS NOT INDICATED ON THE DRAWINGS AND/OR PANEL TATE OF OF THE CONTRACTOR. COMPLETELY AROUND RECEPTACLE BODY AND HAVE INTEGRAL , RIVETLESS GROUNDING SCHEDULES, REFER TO SPECIFICATIONS AND THE NEC FOR MINIMUM SIZE REQUIRED. CONTACTS. THE RECEPTACLE GROUNDING CONTACTS ARE FORMED DIRECTLY OUT OF 6. TAGS SHALL BE PERMANENTLY AFFIXED WITH SCREWS, ADHESIVES ARE NOT �`i�,� 2. THE DIVISION 16 INSTALLER IS RESPONSIBLE FOR THE PURCHASE (OTHER 1HAN THE BACKSTRAP METAL. THEY SHALL NOT BE SEPARATE PIECES AFFIXED TO THE ACCEPTABLE. C. BRANCH CIRCUITS ON THE DRAWINGS ARE GENERALLY NOT SHOWN GROUPED IN SINGLE '',�J OWNER SUPPLIED EQUIPMENT), RIGGING, ERECTION, INSTALLATION AND FUNCTIONAL BACKSTRAP. RACEWAYS AND SHARING COMMON NEUTRALS, HOWEVER, GROUPING IS ALLOWED UNDER CERTAIN BrlTr OPERATION OF ALL ELECTRICAL EQUIPMENT EXCEPT WHERE NOTED, 7. ALL POWER RECEPTACLES SHALL HAVE CIRCUIT ID LABEL, THIS LABEL SHALL BE A CONDITIONS. REFER TO DIVISION 16 SPECIFICATIONS FOR REQUIREMENTS. 7. GROUND FAULT CIRCUIT INTERRUPTERS: PROVIDE U.L LISTED GROUND FAULT CLEAR LAMINATED MYLAR TYPE TAPE, WITH .25" BLACK LETTERING, LABEL SHALL BE CA79 3. ALL LOCATIONS OF EQUIPMENT AND FIXTURES ARE APPROXIMATE AND MAY REQUIRE CIRCUIT INTERRUPTER RECEPTACLES FOR PERSONNEL PROTECTION, WHICH OTHERWISE APPLIED HORIZONTAL POSITION ON THE TOP OF RECEPTACLE FACEPLATE. D. THE DRAWINGS GENERALLY INDICATE QUANTITY OF CONDUCTORS ON BRANCH CIRCUIT HOME RUNS MINOR ADJUSTMENT TO SUIT FIELD CONDITIONS, ALL ADJUSTMENTS SHALL BE MEET THIS SPECIFICATION, WHERE REQUIRED. DEVICES SHALL BE 20A, AND SHALL ONLY. ELSEWHERE WITHIN CIRCUITS, PROVIDE QUANTITY OF CONDUCTORS AS NEEDED TO REVISIONS SUBMITTED TO THE ENGINEER FOR APPROVAL. HAVE A DEDICATED INSULATED GREEN GROUND WIRE RUN CONTINUOUS (UNSPLICED) ACCOMPLISH CIRCUITING AND SWITCHING REQUIREMENTS SHOWN. BETWEEN THE DEVICE AND THE GROUND BUS. REV � DATE DESCRIPTION 19. COMPLETE SYSTEMS: PROVIDE LABOR, MATERIALS, EQUIPMENT, AND TRANSPORTATION TO RECEIVE, INSTALL, 8. WALL SWITCHES: 20A -120-277V AC CONTACTS. TOGGLE TYPE, QUIET ACTION WITH ADJUST, AND PUT INTO OPERATION COMPLETE ELECTRICAL SYSTEMS IN ACCORDANCE WITH THE INTENT OF THE Q - - SEPARATED SCREW TERM FOR THE GROUND WIRE. SCREWLESS PUSH -IN WIRING TERM CONTRACT DOCUMENTS. PROVIDE PRODUCTS NOT MENTIONED BUT OBVIOUSLY NECESSARY AND INCIDENTAL TO SHALL NOT BE USED. PROVIDE SINGLE POLE, SINGLE THROW, UNLESS DRAWINGS THE COMPLETION OF THIS WORK. INDICATE WAY, 4 -WAY, DOUBLE POLE, KEY OPERATED, SPDT MOMENTARY, OR ANY 20. SCOPE: WORK SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: MECHANICAL WORK AS REQUIRED RACEWAY OTHER SPECIAL FEATURES. FOR COORDINATION, POWER DISTRIBUTION, FIRE ALARM SYSTEM, AND INSTALLATION OF MATERIALS. ® - 1. MINIMUM CONDUIT SIZES SHALL BE 3/4". 9, SWITCHES FOR SPECIAL PURPOSE: SPECIAL SWITCHES USED FOR DISCONNECTION 21. UTILITIES: COORDINATE WITH ALL UTILITY SERVICES. NOTIFY UTILITIES OF COMMENCEMENT OF WORK. MAKE 0 - PURPOSES (SMALL APPLIANCES, ETC.) SHALL BE RATED AS SPECIFIED OR REQUIRED. ALL ARRANGEMENTS FOR TEMPORARY SERVICES, PROVIDE ALL WORK AND MATERIALS NECESSARY TO COMPLY WITH © - 2. PROVIDE COMPLETE RACEWAY SYSTEMS FOR ALL WIRING UNLESS OTHERWISE NOTED. ALL UTILITY REGULATIONS AND REQUIREMENTS. THIS INCLUDES FEEDERS, BRANCH CIRCUITS, CONTROL WIRING, AND SYSTEMS WIRING. 7 _ - LOCATIONS OF CONDUITS SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE AND 22. EXPERIENCE: ALL WORK DONE SHALL BE PERFORMED BY QUALIFIED ELECTRICIANS, UNDER THE SUPERVISION A - - ALL LOCAL AND STATE REGULATIONS. AND DIRECTION OF A SUPERINTENDENT HAVING SUCCESSFUL EXPERIENCE INSTALLING AND SUPERVISING EQUIPMENT ENCLOSED SWITCHES AND SYSTEMS OF SIMILAR TYPE AND SIZE AS INDICATED BY CONTRACT DOCUMENTS. - - 3. TRANSITIONS FROM CONCRETE ENCASEMENT: WHERE PVC CONDUIT IS USED FOR DATE 03.16.17 RUNS UNDERGROUND OR IN SLABS, AS OUTLINED HEREIN, A CONVERSION TO RIGID 1, PROVIDE HEAVY DUTY TYPE ENCLOSED SWITCHES, SQUARE. D CLASS 3110 TYPE HD. 23. REGULATIONS: ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH CURRENT RULES, REGULATIONS, AND STEEL "ELL" SHALL BE USED TO EXIT EARTH OR ENCASEMENT. PROVIDE SWEEPING SWITCHES SHALL HAVE EXTERNALLY OPERATED HANDLES WITH PROVISIONS FOR PAD INDUSTRY STANDARDS OF THE N.E.C., UL, IPCEA, NEMA, NFPA, OSHA, NATIONAL ELECTRICAL SAFETY CODE, AND DRAWN BY B.M.A. ELBOWS WITH LARGEST POSSIBLE RADIUS FOR ALL CHANGES OF DIRECTION. LOCKING IN THE OFF OR ON POSITION. PROVIDE NEMA 3R OR 4X STAINLESS STEEL ANY LOCAL CODES, LAWS, ADA OR ORDINANCES. IN THE EVENT THAT A DISCREPANCY IS FOUND IN THE UNITS AS INDICATED ON THE DRAWINGS. CONTRACT DOCUMENTS THE ENGINEER SHALL BE N011FIED IMMEDIATELY. DESIGNED BY B.M.A. 4. PROVIDE AN INSULATED -THROAT METALLIC OR ALL -PLASTIC BUSHING ON ALL EMT, APPROVED BY B.T.B. IMC, AND RIGID METALLIC RACEWAY STUBS AND TERMINATION IN PANELS, 2. WHERE REQUIRED: PROVIDE ALL ENCLOSED DISCONNECT SWITCHES INDICATED ON 24. COSTS AND CONDITIONS: EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS IN THEIR SWITCHBOARDS, CABINETS, PULL BOXES, JUNCTIONS BOXES, GUTTERS, AND OTHER THE DRAWINGS. WHERE A CIRCUIT SERVES A MOTOR, MOTOR CONTROLLER, FIXED ENTIRETY, SURVEY THE PROJECT AND BECOME FAMILIAR WITH EXISTING CONDITIONS AND SCOPE OF WORK. ALL PROJECT NUMBER 17119-00 ENCLOSURES, ELECTRIC SPACE HEATING UNIT, OR APPLIANCE AND A LOCAL DISCONNECT SWITCH IS COSTS SUBMITTED SHALL BE BASED ON A THOROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY NOT INDICATED ON THE DRAWINGS, PROVIDE A LOCAL DISCONNECT UNLESS ONE OF ADDITIONAL COSTS DUE TO FAILURE TO COMPLY WITH THIS REQUIREMENT SHALL BE THE RESPONSIBILITY OF THE DRAWING 5. CEILING GRID SHALL NOT SUPPORT ANY CABLE OR RACEWAY. THE NEC EXCEPTIONS PERTAIN, CONTRACTOR, E-1 1 0 2 0 3 ■ 4 0 5 0 6 0 7 m 8 0 9 0 10 ■ 11 m 12 0 13 ■ 1Ll 0 15 ■ A ■ B ■ C ■ D ■ E F e , K ■ ■ _ J K ELECTRICAL SPECIFICATIONS GENERAL NOTES GENERAL WIRE AND CABLE PANEL BOARDS 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2014 N.E.C., F.B.C. 2014 AND ANY OTHER APPLICABLE STATE 26, SPECIFICATIONS: BECOME FAMILIAR WITH ALL SPECIFICATIONS, DESIGN CRITERIA, AND EQUIPMENT AND LOCAL REQUIREMENTS, REQUIREMENTS PRIOR TO ANY EQUIPMENT PURCHASE OR INSTALLATION. REFERENCE SPECIFICATIONS FOR DEVICES, 1. ALL WORK PERFORMED AND MATERIALS PROVIDED SHALL CONFORM TO THE 2014 1. ALL WIRE SHALL BE COPPER WITH INSULATED RATED AT 600 VOLTS, 75 DEGREES 1. FURNISH AND INSTALL ALL PANELS SHOWN ON THE DRAWINGS, PANELS MUST MATERIALS AND WORKMANSHIP REQUIREMENTS. ADDITIONAL REQUIREMENTS ARE GIVEN IN THESE NOTES AND THE NATIONAL ELECTRICAL CODE (NEC) AND ALL OTHER APPLICABLE STANDARDS, CODES CELSIUS MINIMUM UNLESS OTHERWISE NOTED. MATCH EXISTING MANUFACTURER, THIS EQUIPMENT SHALL BE FACTORY ASSEMBLED 2. THE DRAWINGS ARE DIAGRAMMATIC AND THE OMISSION OF AN ITEM NECESSARY FOR THE PROPER FUNCTIONING DRAWINGS. THERE SHALL BE NO DEVIATION FROM SPECIFICATIONS WITHOUT THE WRITTEN APPROVAL OF THE AND LAWS. THE EDITION OR YEAR -DATE FOR ALL CODES AND STANDARDS SHALL BE UNIT ONLY. ON THE SYSTEM DOES NOT RELIEVE THE ELECTRICAL CONTRACTOR FROM SUPPLYING THAT ITEM, ENGINEER. THAT CURRENTLY ADOPTED BY THE MUNICIPALITY OR OTHER LOCAL AUTHORITY HAVING 2. MINIMUM WIRE SIZES SHALL BE #12 FOR POWER WIRING. JURISDICTION. 2. PANEL BOARDS SHALL BE PAINTED WITH GRAY LACQUER RUST PREVENTATIVE 3. THE DESIGN IS BASED ON THHW/THHN COPPER CONDUCTORS, 27. COORDINATION: COORDINATE WORK WITH ALL OTHER TRADES, GIVE SPECIAL CONSIDERATION TO 3. WIRE SHALL BE SOLID TYPE OR THHN/THWN UP TO SIZE 10 AWG AND STRANDED PRIMER. SIDES AND TOP OF SURFACE MOUNTED PANELS SHALL BE PAINTED TO MATCH COORDINATING INSTALLATION OF LIGHTING, SPRINKLER PIPING, AND DUCTWORK. COORDINATE WALL OUTLET 2. COORDINATE ALL ELECTRICAL WORK WITH THAT OF OTHER TRADES, TYPE THWN OR XHHW FOR SIZE 8 AWG AND LARGER (UNLESS OTHERWISE NOTED). FRONTS, 4. ALL EXIT AND EMERGENCY LIGHTS SHALL BE CONNECTED TO THE UNSWITCHED LEG OF THE LOCAL LIGHTING LOCATIONS WITH MILLWORK. COORDINATE WALL SWITCHES WITH DOOR SWINGS. VERIFY EXACT LOCATION, COLOR CIRCUIT. AND FINISH OF OUTLETS AND DEVICES WITH INTERIOR DESIGNER, ARCHITECT, OR DESIGNATED TENANT B UHOLTZ PROFESSIONAL 3. INSPECTION: PRIOR TO ALL WORK OF THIS SECTION, CAREFULLY INSPECT THE 4, TERMINAL LUGS SHALL BE MECHANICAL CLAMP OR COMPRESSION TYPE UNLESS 3. PANELS SHALL BE OF THE CIRCUIT BREAKER TYPE UNLESS OTHERWISE NOTED AND REPRESENTATIVE PRIOR TO INSTALLATION. INSTALLED WORK OF ALL OTHER TRADES AND VERIFY THAT ALL SUCH WORK IS PART OF A CIRCUIT BREAKER OR SWITCH ASSEMBLY. SET SCREW TYPE LUGS IN WHICH SHALL HAVE CAPACITY AND ARRANGEMENT AS SHOWN ON THE PANEL SCHEDULES OR 5, THE LOCATION AND SIZE OF LOADS SHALL BE CHECKED WITH THE OWNER, ARCHITECT OR APPROPRIATE COMPLETE TO THE POINT WHERE THIS INSTALLATION MAY PROPERLY COMMENCE. THE SET SCREW BEARS DIRECTLY ON THE CONDUCTOR SHALL NOT BE USED, ONE -LINE DIAGRAM. SUBCONTRACTOR AND ADJUSTMENTS MADE ACCORDINGLY. 28, PRODUCTS: ALL PRODUCTS SHALL BE NEW, SPECIFICATION GRADE. PRODUCTS OF A SIMILAR NATURE SHALL ENGINEERING, INC. BE OF THE SAME TYPE AND MANUFACTURER, PROVIDE THE STANDARD PRODUCTS OF MANUFACTURERS REGULARLY 154 Tuskawilla Rd., Ste. 1380 Winter Springs FL 32708 4. INTERFERENCE: AVOID INTERFERENCE WITH STRUCTURE AND WITH WORK OF OTHER 5. UNDER NO CIRCUMSTANCES SHALL FEEDERS BE SPLICED. 4, BRANCH CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE AND SHALL BE OF THE 6. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR LOCATION OF ALL EXISTING UTILITIES IN THE VICINITY OF ENGAGED IN THE PRODUCTION OF SPECIFIED PRODUCTS, UNLESS OTHERWISE REQUIRED BY DRAWINGS. ALL TRADES, PRESERVING ADEQUATE HEADROOM AND CLEARING ALL DOORS AND AMBIENT COMPENSATED, THERMAL MAGNETIC TYPE, WHICH WILL PROVIDE INVERSE TIME CONSTRUCTION AND SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGES HE CAUSES. PRODUCTS SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH NATIONALLY RECOGNIZED AND Ph 407-327-3300 PASSAGEWAYS. 6. COLOR CODE THE ENTIRE POWER WIRING SYSTEM IN ACCORDANCE WITH THE DELAY OVERLOAD AND INSTANTANEOUS SHORT CIRCUIT PROTECTION. VOLTAGE AND ACCEPTED STANDARDS AND PROCEDURES, CA 00009600 NATIONAL ELECTRICAL CODE, AND ALL STATE AND LOCAL CODES. CURRENT RATINGS SHALL BE AS INDICATED ON THE DRAWINGS, 7. COORDINATE ALL ELECTRICAL WORK WITH THAT OF OTHER TRADES PRIOR TO THE INSTALLATION OF THAT WORK. F LOCATIONS LL EXISTING UTILITIES. 30. COMPATIBILITY: ALL NEW 5. THE CONTRACTOR SHALL CONFIRM THEOF W ELECTRICAL DISTRIBUTION EQUIPMENT SHALL MATCH AND BE COMPATIBLE WITH THESE PLANS AND DESIGNS SHOWN HEREON CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING UTILITIES TO 7. PROVIDE A COMPLETE CONTROL WIRING SYSTEM FOR ALL ELECTRICAL EQUIPMENT 5. PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH PANEL, PLACED INSIDE THE PANEL 8. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL INSPECTIONS, ALL CERTIFICATES, AND PERMITS REQUIRED, EXISTING EQUIPMENT, BY MANUFACTURER TYPE, APPLICATION, AND SHORT CIRCUIT RATING. REMAIN THE PROPERTY 0 B U 0 DOOR. DIRECTORIES SHALL BE INSTALLED IN A METAL DIRECTORY FRAME WITH CLEAR INCLUDING ALL ASSOCIATED FEES BY THE LOCAL CODE ENFORCEMENT AGENCY. F H LTE THE BUILDING. AND APPLIANCES, INCLUDING ALL OWNER -FURNISHED EQUIPMENT. EQUIPMENT PROFESSIONAL ENGINEERING, INC. THEIR USE FURNISHED UNDER OTHER DIVISIONS MECHANICAL EQUIPMENT, ETC. SHALL BE PROTECTIVE COVER. SPARES AND SPACES SHALL BE NOTED. 31. IDENTIFICATION: ALL ELECTRICAL DISTRIBUTION EQUIPMENT, TRANSFORMERS, PANELBOARDS AND OTHER 6. BEFORE ORDERING ANY MATERIALS OR EQUIPMENT, THE CONTRACTOR SHALL SUBMIT ( ) 9. THESE DRAWINGS AND PROJECT MANUAL ARE COMPLIMENTARY. IT IS THE CONTRACTORS RESPONSIBILITY TO ENCLOSED EQUIPMENT SHALL BE IDENTIFIED AS INDICATED IN THE CONTRACT DOCUMENTS. SAID IDENTIFICATION WITHOUT WRITTEN LICENSE IS PROHIBITED. PROPERLY INSTALLED WITH ELECTRICAL CIRCUITS AND CONNECTIONS, DISCONNECTS, COPYRIGHT B U H O L T Z PROFESSIONAL SHALL CONSIST OF PERMANENTLY ATTACHED ENGRAVED LAMINATED PLASTIC NAMEPLATES. EACH BRANCH ENGINEERING DATA FOR ALL MATERIALS AND EQUIPMENT HE PROPOSES TO USE AND STARTERS, OPERATOR CONTROL PUSH -BUTTONS, ALARMS, ETC, AS SPECIFIED FOR 6. EACH PANEL SHALL BE EQUIPPED WITH A GROUND LUG/BUS. EXAMINE THE DRAWINGS AND SPECIFICATIONS AND TO COMPARE THE REQUIREMENTS OF EACH DIVISION (i.e. ENGINEERING, INC. ALL RIGHTS RESERVED FURNISH. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING EQUIPMENT EACH TYPE OF ITEM. ELECTRICAL, ETC.) AND ENSURE THAT EACH TRADE OR SUBCONTRACTOR IS MAKING THE ALLOWANCES NECESSARY CIRCUIT OVERCURRENT PROTECTION DEVICE SHALL BE IDENTIFIED BY CIRCUIT NUMBER AND SCHEDULED INSIDE DIMENSIONS OF PROPOSED SUBSTITUTE EQUIPMENT AND SHALL BE RESPONSIBLE FOR 7. EACH PANEL AND CABINET AND THE UNITS COMPRISING SAME SHALL BEAR THE TO PROVIDE THE OWNER A COMPLETE FACILITY OPERATIONAL IN ALL RESPECTS, UNLESS OTHERWISE SPECIFICALLY PANEL DOOR. EACH BRANCH CIRCUIT SPLICE OR TERMINATION SHALL BE IDENTIFIED BY PANEL AND CIRCUIT ITS FITTING IN THE SPACES ALLOWED. THE COST OF ANY REDESIGNING CAUSED BY A 8, ALL SWITCHES FOR CONTROLS, SIGNALS, PILOTS, REMOTE TRIP OPERATORS, MANUFACTURER'S NAMEPLATE AND THE UL LABEL. NOTED IN THE DRAWINGS, IT IS ALSO THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE ARCHITECT/ENGINEER OF DESIGNATION SHOWN ON THE JUNCTION OR OUTLET BOX, OR UPON INDIVIDUAL WIRES IN CASES WHERE MORE SUBSTITUTION SHALL BE BORNE BY THE CONTRACTOR. RAISE/LOWER SWITCHES, REMOTE START/STOP MOTOR CONTROL STATIONS, AND ANY ANY DEFICIENCIES OR DISCREPANCIES AMONG THE DIVISIONS OF THE DRAWINGS AND SPECIFICATIONS PRIOR TO THAN ONE OF EACH PHASE CONDUCTOR OCCUR, OTHER DEVICES THAT ARE REQUIRED BY THE SYSTEM SHALL BE PROVIDED AND 8. CIRCUIT BREAKERS SHALL BE MANUFACTURED BY THE MANUFACTURER OF THE THE BID DATE, NEITHER THE OWNER NOR ARCHITECT/ENGINEER WILL BE RESPONSIBLE FOR ANY DEFICIENCIES OR 7. ALL ELECTRICAL MATERIALS AND EQUIPMENT SHALL BE UL LISTED. ALL MATERIALS INSTALLED BY THE CONTRACTOR. PANEL BOARDS. THERE SHALL BE NO EXCEPTION TO THIS. DISCREPANCIES RAISED AFTER THE BID OPENING. ACCORDINGLY, IN LIGHT OF THESE OBLIGATIONS, THE 32, WIRING: ALL CONDUCTORS CARRYING GREATER THAN 50 VOLTS SHALL BE MINIMUM #12 AWG, SOLID, CU, AND EQUIPMENT SHALL BE NEW, NON -SECONDARY MARKET PRODUCTS. ANY ARCHITECT/ENGINEER IS OBLIGATED TO INTERPRET THE DRAWINGS AND SPECIFICATIONS IN A MANNER THAT WILL SOFT DRAWN OF 98% CONDUCTIVITY, UNLESS NOTED OTHERWISE, EQUIPMENT RECONDITIONED AND/OR RE -PACKAGED WITHOUT FACTORY AUTHORIZA11ON 9. GROUNDING CONDUCTORS: ALL GROUNDING ELECTRODE CONDUCTORS AND 9. MOUNT PANELS IN LOCATIONS SHOWN, MAKING SURE THAT CODE REQUIRED PROVIDE THE OWNER WITH A COMPLETE, FUNCTIONING FACILITY FOR THE BID PRICE. IS UNACCEPTABLE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSULATED COPPER (AS SPECIFIED CLEARANCES EXIST. 8. THIS CONTRACTOR SHALL DO ALL CUTTING, DRILLING AND PATCHING REQUIRED BY ABOVE) UNLESS INDICATED OTHERWISE. 10. IF PAINT IS DAMAGED DURING SHIPPING OR INSTALLATION, DAMAGED PORTION 10. ANY AND ALL DEVIATIONS FROM SPECIFIED PRODUCTS MUST BE APPROVED BY THE ENGINEER. �� HIS WORK. ALL REPAIRS TO FINISH SHALL MATCH THE EXISTING, LEAVING NO 10. BRANCH CIRCUITS MAY BE GROUPED IN SINGLE RACEWAYS AND SHARE A COMMON SHALL BE SANDED SMOOTH AND ENTIRE PANEL REPAINTED. 11. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE APPLICABLE STATE, FEDERAL AND LOCAL CODES. `co DISCERNIBLE SCARS. STRUCTURAL MEMBERS SHALL NOT BE CUT UNLESS APPROVED NEUTRAL PROVIDED THE FOLLOWING GUIDELINES ARE MET AND/OR UNLESS THE" ALL NECESSARY LICENSES AND PERMITS SHALL BE OBTAINED BY THE CONTRACTOR AT HIS EXPENSE UNLESS �'■ BY THE ARCHITECT. DRAWINGS INDICATE OTHERWISE. 11. LIGHTING CIRCUIT BREAKERS SHALL BE SWD RATED. PREVIOUSLY OBTAINED BY THE OWNER. 9. THE CONTRACTOR SHALL PROVIDE A ONE-YEAR GUARANTEE FOR ITEMS FURNISHED A. DEDICATED CIRCUITS: PROVIDE A NEUTRAL PER PHASE CONDUCTOR FOR ALL 12, THE EXISTENCE AND LOCATION OF EXISTING UTILITIES ARE NOT GUARANTEED AND SHALL BE INVESTIGATED O THAT SHALL COVER: DEDICATED CIRCUITS. PROVIDE DEDICATED HOMERUN RACEWAY FOR EACH DEDICATED AND VERIFIED IN THE FIELD BY THE CONTRACTOR BEFORE STARTING WORK. EXCAVATION IN THE VICINITY OF rrnn A: FAULTY OR INADEQUATE DESIGN BY CONTRACTOR. CIRCUIT WHEN INDICATED ON DRAWINGS. - EXISTING STRUCTURES AND UTILITIES SHALL BE CAREFULLY PERFORMED, BY HAND. THE CONTRACTOR SHALL BE VJ B: IMPROPER ASSEMBLY OR ERECTION. HELD RESPONSIBLE FOR ANY DAMAGES TO, AND FOR PROPER MAINTENANCE PROTECTION OF, EXISTING UTILITIES O Z C: DEFECTIVE WORKMANSHIP AND MATERIALS. B. SINGLE PHASE, THREE WIRE SYSTEMS: PROVIDE A NEUTRAL CONDUCTOR FOR GROUNDING AND STRUCTURES DURING THE CONSTRUCTION PROCESS. THE CONTRACTOR SHALL BE LIABLE FOR ANY COSTS O Z O 10, CONTRACTOR SHALL PROVIDE/INSTALL ALL ELECTRICAL SYSTEMS REQUIRED BY EACH GROUP OF TWO SEQUENCED LINE CONDUCTORS. ASSOCIATED WITH THE RELOCATION OF TELEPHONE OR GAS LINES BY THE UTILITY COMPANIES. O ...�.. THIS PROJECT. THIS INCLUDES ALL MISCELLANEOUS ITEMS AND ACCESSORIES REQUIRED 1. PROVIDE A COMPLETE EQUIPMENT SAFETY GROUND SYSTEM (GREEN WIRE GROUND) O FOR THE COMPLETE AND CORRECT OPERATION FOR THE ENTIRE SYSTEM, WHETHER OR 11. CONTRACTOR SHALL VERIFY EXACT DISTANCES FOR FEEDER AND BRANCH CIRCUITS FOR THE ENTIRE ELECTRICAL SYSTEM AS REQUIRED BY ARTICLE 250 OF THE NEC AND 13. THE CONTRACTOR SHALL PROVIDE SAFE, SUFFICIENT, AND PROPER FACILITIES AT ALL TIMES FOR THE NOT SUCH ITEMS ARE ILLUSTRATED IN THE PROJECT DOCUMENTS. AND MAKE ANY APPLICABLE ADJUSTMENTS TO THE WIRE SIZES FOR VOLTAGE DROP. AS SPECIFIED HEREIN. INSPECTION OF THE WORK BY THE OWNER, ARCHITECT, AND ALL APPROPRIATE GOVERNMENTAL AND REGULATORY PANEL FEEDERS SHALL HAVE LESS THAN 2% VOLTAGE DROP AND BRANCH CIRCUITS AGENCIES. SHALL HAVE LESS THAN 3% VOLTAGE DROP. 2. ALL GROUNDING WIRE; LUGS, JUMPERS AND BUS SHALL BE COPPER. O �- 14. UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS OR OTHERWISE INSTRUCTED BY THE ARCHITECT, 3, ALL FEEDER AND BRANCH CIRCUITS SHALL CONTAIN AN EQUIPMENT GROUND WIRE. ELECTRICAL OUTLETS SHALL HAVE THE FOLLOWING MOUNTING HEIGHTS, DIMENSIONS ARE TO CENTER OF BOX 1..` NO METAL CONDUIT OF ANY KIND OR LENGTH SHALL BE USED AS THE EQUIPMENT UNLESS OTHERWISE NOTED: Q 0 U DRAWINGS BOXES GROUNDING CONDUCTOR. ��nn 1. PROVIDE OUTLET BOXES FOR ALL SWITCHES FIXTURES, RECEPTACLES AND ALL # v� 1. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE, BUT SHOW VARIOUS COMPONENTS WALL SWITCHES4. EQUIPMENT GROUNDING CONDUCTORS AND STRAPS SHALL BE SIZED IN ACCORDANCE " Z U OF THE SYSTEMS APPROXIMATELY TO SCALE AND ATTEMPT TO INDICATE HOW THEY OTHER OUTLET DEVICES. WALL CONVENIENCE RECEPTACLES 16 AFF TO BOTTOM OF BOX Q �n cls ARE TO BE INTEGRATED WITH OTHER PARTS OF THE BUILDING. DETERMINE EXACT WITH NEC. REFER TO FEEDER SCHEDULES FOR GROUND WIRE REQUIREMENTS WHICH WALL TELEPHONE OUTLETS 16" AFF TO BOTTOM OF BOX O co O MAY BE EXCEED THE NEC. ALL EQUIPMENT GROUNDING CONDUCTORS SHALL BE LOCATIONS BY REVIEW OF EQUIPMENT MANUFACTURERS DATA, BY JOB SITE 2. JUNCTION AND PULL BOXES SHALL HAVE SCREW -ON COVERS OR LOCKING HINGED WALL OUTLETS FOR WALL MTD. TELEPHONE O r MEASUREMENTS, PROVIDED WITH GREEN INSULATION EQUIVALENT TO THE INSULATION ON THE * .....1 Z BY CHECKING THE REQUIREMENTS OF OTHER TRADES, AND BY COVERS. NEMA 1 BOXES SHALL BE USED INDOORS. NEMA 3R BOXES WITH THREADED ASSOCIATED PHASE CONDUCTORS. MANUAL FIRE ALARM PULL STATIONS REVIEWING ALL CONTRACT DOCUMENTS. THE SIZE OF ELECTRICAL EQUIPMENT INDICATED HUBS SHALL BE USED OUTDOORS. FIRE ALARM SPEAKER/HORN 1'-0" BELOW CEILING, OR IN CEILING, AS REQUIRED W = ON THE DRAWINGS MAY BE BASED ON THE DIMENSIONS OF A PARTICULARINTERIOR BELLS BUZZERS HORNS 1'-0" BELOW CEILING OR IN CEILING AS REQUIRED 5. THE EQUIPMENT GROUNDING SYSTEM SHALL BE INSTALLED SO THAT ALL METALLIC " Z MANUFACTURER. WHILE OTHER LISTED MANUFACTURERS MAY BE ACCEPTABLE IT IS THE 3, BOXES SHALL BE SIZED IN ACCORDANCE WITH NEC ARTICLE 370. STRUCTURES ENCLOSURES RACEWAYS JUNCTION BOXES OUTLET BOXES CABINETS SPECIAL PURPOSE WALL OUTLETS 16 AFF TO BOTTOM OF BOX (OR HIGHER AS REQUIRED 0 U RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE IF THE EQUIPMENT THAT MACHINE FRAMES AND PORTABLE EQUIPMENT FRAMES OPERATE CONTINUOUSLY AT TO SERVE EQUIPMENT) CONTRACTOR PROPOSES TO FURNISH WILL FIT IN THE SPACE. 4. INTERIOR BOXES SHALL BE ONE PIECE, GALVANIZED STEEL CONSTRUCTION, GROUND POTENTIAL AND PROVIDE A LOW IMPEDANCE PATH FOR GROUND FAULT PUSH BUTTONS Q SUITABLE/LISTED FOR INTENDED USE. PROVIDE PLASTER -RINGS WHERE REQUIRED. CURRENTS. THE SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE, ADA VISUAL ALARM 80" AFF TO BOTTOM OF LENS OR 6" BELOW CEILING, a:I- 2. THE DRAWINGS ARE NOT INTENDED TO SHOW EXACT LOCATIONS OF CONDUIT, WIRE, INSTALL "GANGED" BOXES WHERE DEVICES ARE INDICATED TO BE GROUPED. WHICHEVER IS LOWER. ENTIRE LENS TO BE WITHIN 1 OR TO INDICATE ALL WIRE TERMINATORS, CONNECTORS, CONDUIT FITTINGS, BOXES, OR 6. GROUNDING CONDUCTORS SHALL BE CONTINUOUS AND NO SPLICING SHALL BE 80" to 96" AFF + ra. 0 SUPPORTS, BUT RATHER TO INDICATE DISTRIBUTION, CIRCUITRY, AND CONTROL. 5. EXTERIOR BOXES SHALL BE ONE PIECE PVC "UV PROTECTED". ALLOWED, 7 V J W # TOP OF BOX SHALL BE 48" AFF MAX. FOR WHEELCHAIR L 3. THE VARIOUS PHASES OF WORK. THE WORK SHALL BE LAID OUT SO THAT IT WILL 6. ALL CONDUIT CONNECTORS AND ENTRY HUBS SHALL BE INSULATED OR HAVE 7. PROVIDE COPPER GROUND BUSSES ON WALLS WHERE INDICATED ON THE DRAWINGS FRONTAL APPROACH AND 54" AFF MAX. FOR SIDE J BE CONCEALED IN FURRED CHASES AND SUSPENDED CEILINGS, ETC., IN FINISHED INSULATED BUSHINGS, AND WHERE SPECIAL GROUNDING NEEDS WILL ARISE, REFERENCE DETAIL ON DRAWING APPROACH, VERIFY EXACT HEIGHT WITH ARCHITECT. W PORTIONS OF THE BUILDING, UNLESS SPECIFICALLY NOTED TO BE EXPOSED. WORK FOR GROUND BUS AND CONNECTION REQUIREMENTS. SHALL BE INSTALLED TO AVOID CRIPPLING OF STRUCTURAL MEMBERS. ALL EXPOSED AFF = ABOVE FINISHED FLOOR WORK SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO THE LINES OF THE 8. WHERE REQUIRED, EMT CONNECTORS OR FLEXIBLE CONDUIT FITTINGS SHALL BE AFG = ABOVE FINISHED GRADE W BUILDING UNLESS OTHERWISE NOTED. WIRING DEVICES BONDED USING A CONDUIT LOCKNUT, T&B SERIES #106 OR EQUIVALENT, UL LISTED, 4. WHEN THE MECHANICAL AND ELECTRICAL DRAWINGS DO NOT GIVE EXACT DETAILS 1. PROVIDE A COMPLETE SYSTEM OF WIRING DEVICES PROPERLY WIRED, INCLUDING A 15. UNLESS SPECIFICALLY INDICATED ON THE ELECTRICAL DRAWINGS, OUTLETS LOCATED AT COUNTERS AND AS THE THE ELEVATION OF PIPE, CONDUIT AND DUCTS, PHYSICALLY ARRANGE THE SOLID GROUNDING CONNECTION. CABINETS SHALL BE MOUNTED AS SHOWN ON ARCHITECTURAL DETAILS AND ELEVATIONS, OR AS DIRECTED BY SYSTEMS TO FIT IN THE SPACE AVAILABLE. SPACES SHALL BE PRIORITIZED AS ARCHITECT, REQUIRED TO ALLOW FOR PROPER GRADES OF THE SYSTEMS INVOLVED. 2. UNDERWRITERS LABORATORIES: PROVIDE WIRING DEVICES WHICH ARE LISTED AND IDENEEIC TI N( SS 16. COORDINATE MOUNTING HEIGHTS AND DETAILS OF ALL OUTLETS (POWER, SIGNAL, ETC.) WITH ARCHITECTURAL LABELED BY UL, CASEWORK DRAWINGS PRIOR TO DIVISION 16 ROUGH -IN. PROVIDE COORDINATION DRAWINGS IN ACCORDANCE WITH 3, NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION: WIRING DEVICES SHALL 1. COMPLY WITH GOVERNING REGULATIONS AND REQUESTS OF GOVERNING AUTHORITIES DIVISION 16 SPECIFICATIONS WHERE CONFLICTS EXIST. OBTAIN APPROVAL FROM ARCHITECT BEFORE ELECTRICAL COMPLY WITH APPLICABLE NEMA STANDARDS. FOR IDENTIFICATION OF ELECTRICAL WORK. ROUGH -IN WHEN CONFLICTS ARISE, 4. DEVICE COLOR: WHITE UNLESS OTHERWISE NOTED, 2. PROVIDE NAMEPLATES/LABELS FOR ITEMS WHERE INDICATED AND/OR DESCRIBED IN 17, REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF ALL HVAC AND PLUMBING EQUIPMENT AND EQUIPMENT THESE SPECIFICATIONS. ROUGH -IN REQUIREMENTS SEAL 5. ACCEPTABLE: THE FOLLOWING MANUFACTURERS WILL BE ACCEPTABLE PROVIDING r 1. THE CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE INSTALLATION OF ALL THEY MEET THE PROJECT SPECIFICATIONS: COPPER WIRING DEVICES, ARROW -HART, 3. ALL ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE LABELED. 18. CIRCUITING ®oma°° ��� ��/ EQUIPMENT SHOWN ON THE DRAWINGS. ALL MANUFACTURERS SPECIFICATIONS SHALL HUBBELL, LEVITON, LUTRON, WOODHEAD INDUSTRIES, A. BRANCH CIRCUITING IS SCHEMATIC IN NATURE AND IS INTENDED TO INDICATE CIRCUIT LOADING °��j:'�s BE FOLLOWED IN REGARDS TO THE INSTALLATION OF ALL EQUIPMENT. ANY SPECIAL 4. LABELS SHALL BE ENGRAVED PHENOLIC TAGS WITH MINIMUM .5" TEXT HEIGHT. AND CONTROL, NOT METHODS OF INSTALLATION. REFER TO SPECIFICATIONS FOR METHODS OF MANUFACTURER'S REQUIREMENTS NECESSARY FOR PROPER OR SAFE INSTALLATION OF 6. STANDARD CONVENIENCE OUTLET: 20A/125V/2 POLE/3 WIRE DUPLEX NEMA 5-20R. DYMO (OR EQUIVALENT) LABELS SHALL NOT BE USED, INSTALLATION AND MATERIALS. ' pg EQUIPMENT REGARDLESS OF WHETHER THE AFOREMENTIONED SPECIAL REQUIREMENTS DUPLEX RECEPTACLE, RECEPTACLE FACE SHALL BE HIGH -IMPACT RESISTANT. NYLON 5. COLOR CODE: ALL POWER EQUIPMENT- BLUE FIELD WITH WHITE LETTERS. ARE INDICATED ON THE DRAWINGS, SHALL BE AT THE EXPENSE AND RESPONSIBILITY BODY SHALL BE THERMOPLASTIC POLYESTER. MOUNTING STRAP SHALL WARP B. WHERE WIRE SIZE AND CONDUIT SIZE IS NOT INDICATED ON THE DRAWINGS AND/OR PANEL TATE OF OF THE CONTRACTOR. COMPLETELY AROUND RECEPTACLE BODY AND HAVE INTEGRAL , RIVETLESS GROUNDING SCHEDULES, REFER TO SPECIFICATIONS AND THE NEC FOR MINIMUM SIZE REQUIRED. CONTACTS. THE RECEPTACLE GROUNDING CONTACTS ARE FORMED DIRECTLY OUT OF 6. TAGS SHALL BE PERMANENTLY AFFIXED WITH SCREWS, ADHESIVES ARE NOT �`i�,� 2. THE DIVISION 16 INSTALLER IS RESPONSIBLE FOR THE PURCHASE (OTHER 1HAN THE BACKSTRAP METAL. THEY SHALL NOT BE SEPARATE PIECES AFFIXED TO THE ACCEPTABLE. C. BRANCH CIRCUITS ON THE DRAWINGS ARE GENERALLY NOT SHOWN GROUPED IN SINGLE '',�J OWNER SUPPLIED EQUIPMENT), RIGGING, ERECTION, INSTALLATION AND FUNCTIONAL BACKSTRAP. RACEWAYS AND SHARING COMMON NEUTRALS, HOWEVER, GROUPING IS ALLOWED UNDER CERTAIN BrlTr OPERATION OF ALL ELECTRICAL EQUIPMENT EXCEPT WHERE NOTED, 7. ALL POWER RECEPTACLES SHALL HAVE CIRCUIT ID LABEL, THIS LABEL SHALL BE A CONDITIONS. REFER TO DIVISION 16 SPECIFICATIONS FOR REQUIREMENTS. 7. GROUND FAULT CIRCUIT INTERRUPTERS: PROVIDE U.L LISTED GROUND FAULT CLEAR LAMINATED MYLAR TYPE TAPE, WITH .25" BLACK LETTERING, LABEL SHALL BE CA79 3. ALL LOCATIONS OF EQUIPMENT AND FIXTURES ARE APPROXIMATE AND MAY REQUIRE CIRCUIT INTERRUPTER RECEPTACLES FOR PERSONNEL PROTECTION, WHICH OTHERWISE APPLIED HORIZONTAL POSITION ON THE TOP OF RECEPTACLE FACEPLATE. D. THE DRAWINGS GENERALLY INDICATE QUANTITY OF CONDUCTORS ON BRANCH CIRCUIT HOME RUNS MINOR ADJUSTMENT TO SUIT FIELD CONDITIONS, ALL ADJUSTMENTS SHALL BE MEET THIS SPECIFICATION, WHERE REQUIRED. DEVICES SHALL BE 20A, AND SHALL ONLY. ELSEWHERE WITHIN CIRCUITS, PROVIDE QUANTITY OF CONDUCTORS AS NEEDED TO REVISIONS SUBMITTED TO THE ENGINEER FOR APPROVAL. HAVE A DEDICATED INSULATED GREEN GROUND WIRE RUN CONTINUOUS (UNSPLICED) ACCOMPLISH CIRCUITING AND SWITCHING REQUIREMENTS SHOWN. BETWEEN THE DEVICE AND THE GROUND BUS. REV � DATE DESCRIPTION 19. COMPLETE SYSTEMS: PROVIDE LABOR, MATERIALS, EQUIPMENT, AND TRANSPORTATION TO RECEIVE, INSTALL, 8. WALL SWITCHES: 20A -120-277V AC CONTACTS. TOGGLE TYPE, QUIET ACTION WITH ADJUST, AND PUT INTO OPERATION COMPLETE ELECTRICAL SYSTEMS IN ACCORDANCE WITH THE INTENT OF THE Q - - SEPARATED SCREW TERM FOR THE GROUND WIRE. SCREWLESS PUSH -IN WIRING TERM CONTRACT DOCUMENTS. PROVIDE PRODUCTS NOT MENTIONED BUT OBVIOUSLY NECESSARY AND INCIDENTAL TO SHALL NOT BE USED. PROVIDE SINGLE POLE, SINGLE THROW, UNLESS DRAWINGS THE COMPLETION OF THIS WORK. INDICATE WAY, 4 -WAY, DOUBLE POLE, KEY OPERATED, SPDT MOMENTARY, OR ANY 20. SCOPE: WORK SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: MECHANICAL WORK AS REQUIRED RACEWAY OTHER SPECIAL FEATURES. FOR COORDINATION, POWER DISTRIBUTION, FIRE ALARM SYSTEM, AND INSTALLATION OF MATERIALS. ® - 1. MINIMUM CONDUIT SIZES SHALL BE 3/4". 9, SWITCHES FOR SPECIAL PURPOSE: SPECIAL SWITCHES USED FOR DISCONNECTION 21. UTILITIES: COORDINATE WITH ALL UTILITY SERVICES. NOTIFY UTILITIES OF COMMENCEMENT OF WORK. MAKE 0 - PURPOSES (SMALL APPLIANCES, ETC.) SHALL BE RATED AS SPECIFIED OR REQUIRED. ALL ARRANGEMENTS FOR TEMPORARY SERVICES, PROVIDE ALL WORK AND MATERIALS NECESSARY TO COMPLY WITH © - 2. PROVIDE COMPLETE RACEWAY SYSTEMS FOR ALL WIRING UNLESS OTHERWISE NOTED. ALL UTILITY REGULATIONS AND REQUIREMENTS. THIS INCLUDES FEEDERS, BRANCH CIRCUITS, CONTROL WIRING, AND SYSTEMS WIRING. 7 _ - LOCATIONS OF CONDUITS SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE AND 22. EXPERIENCE: ALL WORK DONE SHALL BE PERFORMED BY QUALIFIED ELECTRICIANS, UNDER THE SUPERVISION A - - ALL LOCAL AND STATE REGULATIONS. AND DIRECTION OF A SUPERINTENDENT HAVING SUCCESSFUL EXPERIENCE INSTALLING AND SUPERVISING EQUIPMENT ENCLOSED SWITCHES AND SYSTEMS OF SIMILAR TYPE AND SIZE AS INDICATED BY CONTRACT DOCUMENTS. - - 3. TRANSITIONS FROM CONCRETE ENCASEMENT: WHERE PVC CONDUIT IS USED FOR DATE 03.16.17 RUNS UNDERGROUND OR IN SLABS, AS OUTLINED HEREIN, A CONVERSION TO RIGID 1, PROVIDE HEAVY DUTY TYPE ENCLOSED SWITCHES, SQUARE. D CLASS 3110 TYPE HD. 23. REGULATIONS: ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH CURRENT RULES, REGULATIONS, AND STEEL "ELL" SHALL BE USED TO EXIT EARTH OR ENCASEMENT. PROVIDE SWEEPING SWITCHES SHALL HAVE EXTERNALLY OPERATED HANDLES WITH PROVISIONS FOR PAD INDUSTRY STANDARDS OF THE N.E.C., UL, IPCEA, NEMA, NFPA, OSHA, NATIONAL ELECTRICAL SAFETY CODE, AND DRAWN BY B.M.A. ELBOWS WITH LARGEST POSSIBLE RADIUS FOR ALL CHANGES OF DIRECTION. LOCKING IN THE OFF OR ON POSITION. PROVIDE NEMA 3R OR 4X STAINLESS STEEL ANY LOCAL CODES, LAWS, ADA OR ORDINANCES. IN THE EVENT THAT A DISCREPANCY IS FOUND IN THE UNITS AS INDICATED ON THE DRAWINGS. CONTRACT DOCUMENTS THE ENGINEER SHALL BE N011FIED IMMEDIATELY. DESIGNED BY B.M.A. 4. PROVIDE AN INSULATED -THROAT METALLIC OR ALL -PLASTIC BUSHING ON ALL EMT, APPROVED BY B.T.B. IMC, AND RIGID METALLIC RACEWAY STUBS AND TERMINATION IN PANELS, 2. WHERE REQUIRED: PROVIDE ALL ENCLOSED DISCONNECT SWITCHES INDICATED ON 24. COSTS AND CONDITIONS: EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS IN THEIR SWITCHBOARDS, CABINETS, PULL BOXES, JUNCTIONS BOXES, GUTTERS, AND OTHER THE DRAWINGS. WHERE A CIRCUIT SERVES A MOTOR, MOTOR CONTROLLER, FIXED ENTIRETY, SURVEY THE PROJECT AND BECOME FAMILIAR WITH EXISTING CONDITIONS AND SCOPE OF WORK. ALL PROJECT NUMBER 17119-00 ENCLOSURES, ELECTRIC SPACE HEATING UNIT, OR APPLIANCE AND A LOCAL DISCONNECT SWITCH IS COSTS SUBMITTED SHALL BE BASED ON A THOROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY NOT INDICATED ON THE DRAWINGS, PROVIDE A LOCAL DISCONNECT UNLESS ONE OF ADDITIONAL COSTS DUE TO FAILURE TO COMPLY WITH THIS REQUIREMENT SHALL BE THE RESPONSIBILITY OF THE DRAWING 5. CEILING GRID SHALL NOT SUPPORT ANY CABLE OR RACEWAY. THE NEC EXCEPTIONS PERTAIN, CONTRACTOR, E-1 1 0 2 0 3 ■ 4 0 5 0 6 0 7 m 8 0 9 0 10 ■ 11 m 12 0 13 ■ 1Ll 0 15 ■ A ■ B ■ C ■ D ■ E F e , K ■ ■ �i K ELECTRICAL SPECIFICATIONS GENERAL NOTES GENERAL WIRE AND CABLE PANEL BOARDS 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2014 N.E.C., F.B.C. 2014 AND ANY OTHER APPLICABLE STATE 26, SPECIFICATIONS: BECOME FAMILIAR WITH ALL SPECIFICATIONS, DESIGN CRITERIA, AND EQUIPMENT AND LOCAL REQUIREMENTS, REQUIREMENTS PRIOR TO ANY EQUIPMENT PURCHASE OR INSTALLATION. REFERENCE SPECIFICATIONS FOR DEVICES, 1. ALL WORK PERFORMED AND MATERIALS PROVIDED SHALL CONFORM TO THE 2014 1. ALL WIRE SHALL BE COPPER WITH INSULATED RATED AT 600 VOLTS, 75 DEGREES 1. FURNISH AND INSTALL ALL PANELS SHOWN ON THE DRAWINGS, PANELS MUST MATERIALS AND WORKMANSHIP REQUIREMENTS. ADDITIONAL REQUIREMENTS ARE GIVEN IN THESE NOTES AND THE NATIONAL ELECTRICAL CODE (NEC) AND ALL OTHER APPLICABLE STANDARDS, CODES CELSIUS MINIMUM UNLESS OTHERWISE NOTED. MATCH EXISTING MANUFACTURER, THIS EQUIPMENT SHALL BE FACTORY ASSEMBLED 2. THE DRAWINGS ARE DIAGRAMMATIC AND THE OMISSION OF AN ITEM NECESSARY FOR THE PROPER FUNCTIONING DRAWINGS. THERE SHALL BE NO DEVIATION FROM SPECIFICATIONS WITHOUT THE WRITTEN APPROVAL OF THE AND LAWS. THE EDITION OR YEAR -DATE FOR ALL CODES AND STANDARDS SHALL BE UNIT ONLY. ON THE SYSTEM DOES NOT RELIEVE THE ELECTRICAL CONTRACTOR FROM SUPPLYING THAT ITEM, ENGINEER. THAT CURRENTLY ADOPTED BY THE MUNICIPALITY OR OTHER LOCAL AUTHORITY HAVING 2. MINIMUM WIRE SIZES SHALL BE #12 FOR POWER WIRING. JURISDICTION. 2. PANEL BOARDS SHALL BE PAINTED WITH GRAY LACQUER RUST PREVENTATIVE 3. THE DESIGN IS BASED ON THHW/THHN COPPER CONDUCTORS, 27. COORDINATION: COORDINATE WORK WITH ALL OTHER TRADES, GIVE SPECIAL CONSIDERATION TO 3. WIRE SHALL BE SOLID TYPE OR THHN/THWN UP TO SIZE 10 AWG AND STRANDED PRIMER. SIDES AND TOP OF SURFACE MOUNTED PANELS SHALL BE PAINTED TO MATCH COORDINATING INSTALLATION OF LIGHTING, SPRINKLER PIPING, AND DUCTWORK. COORDINATE WALL OUTLET 2. COORDINATE ALL ELECTRICAL WORK WITH THAT OF OTHER TRADES, TYPE THWN OR XHHW FOR SIZE 8 AWG AND LARGER (UNLESS OTHERWISE NOTED). FRONTS, 4. ALL EXIT AND EMERGENCY LIGHTS SHALL BE CONNECTED TO THE UNSWITCHED LEG OF THE LOCAL LIGHTING LOCATIONS WITH MILLWORK. COORDINATE WALL SWITCHES WITH DOOR SWINGS. VERIFY EXACT LOCATION, COLOR CIRCUIT. AND FINISH OF OUTLETS AND DEVICES WITH INTERIOR DESIGNER, ARCHITECT, OR DESIGNATED TENANT B UHOLTZ PROFESSIONAL 3. INSPECTION: PRIOR TO ALL WORK OF THIS SECTION, CAREFULLY INSPECT THE 4, TERMINAL LUGS SHALL BE MECHANICAL CLAMP OR COMPRESSION TYPE UNLESS 3. PANELS SHALL BE OF THE CIRCUIT BREAKER TYPE UNLESS OTHERWISE NOTED AND REPRESENTATIVE PRIOR TO INSTALLATION. INSTALLED WORK OF ALL OTHER TRADES AND VERIFY THAT ALL SUCH WORK IS PART OF A CIRCUIT BREAKER OR SWITCH ASSEMBLY. SET SCREW TYPE LUGS IN WHICH SHALL HAVE CAPACITY AND ARRANGEMENT AS SHOWN ON THE PANEL SCHEDULES OR 5, THE LOCATION AND SIZE OF LOADS SHALL BE CHECKED WITH THE OWNER, ARCHITECT OR APPROPRIATE COMPLETE TO THE POINT WHERE THIS INSTALLATION MAY PROPERLY COMMENCE. THE SET SCREW BEARS DIRECTLY ON THE CONDUCTOR SHALL NOT BE USED, ONE -LINE DIAGRAM. SUBCONTRACTOR AND ADJUSTMENTS MADE ACCORDINGLY. 28, PRODUCTS: ALL PRODUCTS SHALL BE NEW, SPECIFICATION GRADE. PRODUCTS OF A SIMILAR NATURE SHALL ENGINEERING, INC. BE OF THE SAME TYPE AND MANUFACTURER, PROVIDE THE STANDARD PRODUCTS OF MANUFACTURERS REGULARLY 154 Tuskawilla Rd., Ste. 1380 Winter Springs FL 32708 4. INTERFERENCE: AVOID INTERFERENCE WITH STRUCTURE AND WITH WORK OF OTHER 5. UNDER NO CIRCUMSTANCES SHALL FEEDERS BE SPLICED. 4, BRANCH CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE AND SHALL BE OF THE 6. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR LOCATION OF ALL EXISTING UTILITIES IN THE VICINITY OF ENGAGED IN THE PRODUCTION OF SPECIFIED PRODUCTS, UNLESS OTHERWISE REQUIRED BY DRAWINGS. ALL TRADES, PRESERVING ADEQUATE HEADROOM AND CLEARING ALL DOORS AND AMBIENT COMPENSATED, THERMAL MAGNETIC TYPE, WHICH WILL PROVIDE INVERSE TIME CONSTRUCTION AND SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGES HE CAUSES. PRODUCTS SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH NATIONALLY RECOGNIZED AND Ph 407-327-3300 PASSAGEWAYS. 6. COLOR CODE THE ENTIRE POWER WIRING SYSTEM IN ACCORDANCE WITH THE DELAY OVERLOAD AND INSTANTANEOUS SHORT CIRCUIT PROTECTION. VOLTAGE AND ACCEPTED STANDARDS AND PROCEDURES, CA 00009600 NATIONAL ELECTRICAL CODE, AND ALL STATE AND LOCAL CODES. CURRENT RATINGS SHALL BE AS INDICATED ON THE DRAWINGS, 7. COORDINATE ALL ELECTRICAL WORK WITH THAT OF OTHER TRADES PRIOR TO THE INSTALLATION OF THAT WORK. F LOCATIONS LL EXISTING UTILITIES. 30. COMPATIBILITY: ALL NEW 5. THE CONTRACTOR SHALL CONFIRM THEOF W ELECTRICAL DISTRIBUTION EQUIPMENT SHALL MATCH AND BE COMPATIBLE WITH THESE PLANS AND DESIGNS SHOWN HEREON CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING UTILITIES TO 7. PROVIDE A COMPLETE CONTROL WIRING SYSTEM FOR ALL ELECTRICAL EQUIPMENT 5. PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH PANEL, PLACED INSIDE THE PANEL 8. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL INSPECTIONS, ALL CERTIFICATES, AND PERMITS REQUIRED, EXISTING EQUIPMENT, BY MANUFACTURER TYPE, APPLICATION, AND SHORT CIRCUIT RATING. REMAIN THE PROPERTY 0 B U 0 DOOR. DIRECTORIES SHALL BE INSTALLED IN A METAL DIRECTORY FRAME WITH CLEAR INCLUDING ALL ASSOCIATED FEES BY THE LOCAL CODE ENFORCEMENT AGENCY. F H LTE THE BUILDING. AND APPLIANCES, INCLUDING ALL OWNER -FURNISHED EQUIPMENT. EQUIPMENT PROFESSIONAL ENGINEERING, INC. THEIR USE FURNISHED UNDER OTHER DIVISIONS MECHANICAL EQUIPMENT, ETC. SHALL BE PROTECTIVE COVER. SPARES AND SPACES SHALL BE NOTED. 31. IDENTIFICATION: ALL ELECTRICAL DISTRIBUTION EQUIPMENT, TRANSFORMERS, PANELBOARDS AND OTHER 6. BEFORE ORDERING ANY MATERIALS OR EQUIPMENT, THE CONTRACTOR SHALL SUBMIT ( ) 9. THESE DRAWINGS AND PROJECT MANUAL ARE COMPLIMENTARY. IT IS THE CONTRACTORS RESPONSIBILITY TO ENCLOSED EQUIPMENT SHALL BE IDENTIFIED AS INDICATED IN THE CONTRACT DOCUMENTS. SAID IDENTIFICATION WITHOUT WRITTEN LICENSE IS PROHIBITED. PROPERLY INSTALLED WITH ELECTRICAL CIRCUITS AND CONNECTIONS, DISCONNECTS, COPYRIGHT B U H O L T Z PROFESSIONAL SHALL CONSIST OF PERMANENTLY ATTACHED ENGRAVED LAMINATED PLASTIC NAMEPLATES. EACH BRANCH ENGINEERING DATA FOR ALL MATERIALS AND EQUIPMENT HE PROPOSES TO USE AND STARTERS, OPERATOR CONTROL PUSH -BUTTONS, ALARMS, ETC, AS SPECIFIED FOR 6. EACH PANEL SHALL BE EQUIPPED WITH A GROUND LUG/BUS. EXAMINE THE DRAWINGS AND SPECIFICATIONS AND TO COMPARE THE REQUIREMENTS OF EACH DIVISION (i.e. ENGINEERING, INC. ALL RIGHTS RESERVED FURNISH. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING EQUIPMENT EACH TYPE OF ITEM. ELECTRICAL, ETC.) AND ENSURE THAT EACH TRADE OR SUBCONTRACTOR IS MAKING THE ALLOWANCES NECESSARY CIRCUIT OVERCURRENT PROTECTION DEVICE SHALL BE IDENTIFIED BY CIRCUIT NUMBER AND SCHEDULED INSIDE DIMENSIONS OF PROPOSED SUBSTITUTE EQUIPMENT AND SHALL BE RESPONSIBLE FOR 7. EACH PANEL AND CABINET AND THE UNITS COMPRISING SAME SHALL BEAR THE TO PROVIDE THE OWNER A COMPLETE FACILITY OPERATIONAL IN ALL RESPECTS, UNLESS OTHERWISE SPECIFICALLY PANEL DOOR. EACH BRANCH CIRCUIT SPLICE OR TERMINATION SHALL BE IDENTIFIED BY PANEL AND CIRCUIT ITS FITTING IN THE SPACES ALLOWED. THE COST OF ANY REDESIGNING CAUSED BY A 8, ALL SWITCHES FOR CONTROLS, SIGNALS, PILOTS, REMOTE TRIP OPERATORS, MANUFACTURER'S NAMEPLATE AND THE UL LABEL. NOTED IN THE DRAWINGS, IT IS ALSO THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE ARCHITECT/ENGINEER OF DESIGNATION SHOWN ON THE JUNCTION OR OUTLET BOX, OR UPON INDIVIDUAL WIRES IN CASES WHERE MORE SUBSTITUTION SHALL BE BORNE BY THE CONTRACTOR. RAISE/LOWER SWITCHES, REMOTE START/STOP MOTOR CONTROL STATIONS, AND ANY ANY DEFICIENCIES OR DISCREPANCIES AMONG THE DIVISIONS OF THE DRAWINGS AND SPECIFICATIONS PRIOR TO THAN ONE OF EACH PHASE CONDUCTOR OCCUR, OTHER DEVICES THAT ARE REQUIRED BY THE SYSTEM SHALL BE PROVIDED AND 8. CIRCUIT BREAKERS SHALL BE MANUFACTURED BY THE MANUFACTURER OF THE THE BID DATE, NEITHER THE OWNER NOR ARCHITECT/ENGINEER WILL BE RESPONSIBLE FOR ANY DEFICIENCIES OR 7. ALL ELECTRICAL MATERIALS AND EQUIPMENT SHALL BE UL LISTED. ALL MATERIALS INSTALLED BY THE CONTRACTOR. PANEL BOARDS. THERE SHALL BE NO EXCEPTION TO THIS. DISCREPANCIES RAISED AFTER THE BID OPENING. ACCORDINGLY, IN LIGHT OF THESE OBLIGATIONS, THE 32, WIRING: ALL CONDUCTORS CARRYING GREATER THAN 50 VOLTS SHALL BE MINIMUM #12 AWG, SOLID, CU, AND EQUIPMENT SHALL BE NEW, NON -SECONDARY MARKET PRODUCTS. ANY ARCHITECT/ENGINEER IS OBLIGATED TO INTERPRET THE DRAWINGS AND SPECIFICATIONS IN A MANNER THAT WILL SOFT DRAWN OF 98% CONDUCTIVITY, UNLESS NOTED OTHERWISE, EQUIPMENT RECONDITIONED AND/OR RE -PACKAGED WITHOUT FACTORY AUTHORIZA11ON 9. GROUNDING CONDUCTORS: ALL GROUNDING ELECTRODE CONDUCTORS AND 9. MOUNT PANELS IN LOCATIONS SHOWN, MAKING SURE THAT CODE REQUIRED PROVIDE THE OWNER WITH A COMPLETE, FUNCTIONING FACILITY FOR THE BID PRICE. IS UNACCEPTABLE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSULATED COPPER (AS SPECIFIED CLEARANCES EXIST. 8. THIS CONTRACTOR SHALL DO ALL CUTTING, DRILLING AND PATCHING REQUIRED BY ABOVE) UNLESS INDICATED OTHERWISE. 10. IF PAINT IS DAMAGED DURING SHIPPING OR INSTALLATION, DAMAGED PORTION 10. ANY AND ALL DEVIATIONS FROM SPECIFIED PRODUCTS MUST BE APPROVED BY THE ENGINEER. �� HIS WORK. ALL REPAIRS TO FINISH SHALL MATCH THE EXISTING, LEAVING NO 10. BRANCH CIRCUITS MAY BE GROUPED IN SINGLE RACEWAYS AND SHARE A COMMON SHALL BE SANDED SMOOTH AND ENTIRE PANEL REPAINTED. 11. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE APPLICABLE STATE, FEDERAL AND LOCAL CODES. `co DISCERNIBLE SCARS. STRUCTURAL MEMBERS SHALL NOT BE CUT UNLESS APPROVED NEUTRAL PROVIDED THE FOLLOWING GUIDELINES ARE MET AND/OR UNLESS THE" ALL NECESSARY LICENSES AND PERMITS SHALL BE OBTAINED BY THE CONTRACTOR AT HIS EXPENSE UNLESS �'■ BY THE ARCHITECT. DRAWINGS INDICATE OTHERWISE. 11. LIGHTING CIRCUIT BREAKERS SHALL BE SWD RATED. PREVIOUSLY OBTAINED BY THE OWNER. 9. THE CONTRACTOR SHALL PROVIDE A ONE-YEAR GUARANTEE FOR ITEMS FURNISHED A. DEDICATED CIRCUITS: PROVIDE A NEUTRAL PER PHASE CONDUCTOR FOR ALL 12, THE EXISTENCE AND LOCATION OF EXISTING UTILITIES ARE NOT GUARANTEED AND SHALL BE INVESTIGATED O THAT SHALL COVER: DEDICATED CIRCUITS. PROVIDE DEDICATED HOMERUN RACEWAY FOR EACH DEDICATED AND VERIFIED IN THE FIELD BY THE CONTRACTOR BEFORE STARTING WORK. EXCAVATION IN THE VICINITY OF rrnn A: FAULTY OR INADEQUATE DESIGN BY CONTRACTOR. CIRCUIT WHEN INDICATED ON DRAWINGS. - EXISTING STRUCTURES AND UTILITIES SHALL BE CAREFULLY PERFORMED, BY HAND. THE CONTRACTOR SHALL BE VJ B: IMPROPER ASSEMBLY OR ERECTION. HELD RESPONSIBLE FOR ANY DAMAGES TO, AND FOR PROPER MAINTENANCE PROTECTION OF, EXISTING UTILITIES O Z C: DEFECTIVE WORKMANSHIP AND MATERIALS. B. SINGLE PHASE, THREE WIRE SYSTEMS: PROVIDE A NEUTRAL CONDUCTOR FOR GROUNDING AND STRUCTURES DURING THE CONSTRUCTION PROCESS. THE CONTRACTOR SHALL BE LIABLE FOR ANY COSTS O Z O 10, CONTRACTOR SHALL PROVIDE/INSTALL ALL ELECTRICAL SYSTEMS REQUIRED BY EACH GROUP OF TWO SEQUENCED LINE CONDUCTORS. ASSOCIATED WITH THE RELOCATION OF TELEPHONE OR GAS LINES BY THE UTILITY COMPANIES. O ...�.. THIS PROJECT. THIS INCLUDES ALL MISCELLANEOUS ITEMS AND ACCESSORIES REQUIRED 1. PROVIDE A COMPLETE EQUIPMENT SAFETY GROUND SYSTEM (GREEN WIRE GROUND) O FOR THE COMPLETE AND CORRECT OPERATION FOR THE ENTIRE SYSTEM, WHETHER OR 11. CONTRACTOR SHALL VERIFY EXACT DISTANCES FOR FEEDER AND BRANCH CIRCUITS FOR THE ENTIRE ELECTRICAL SYSTEM AS REQUIRED BY ARTICLE 250 OF THE NEC AND 13. THE CONTRACTOR SHALL PROVIDE SAFE, SUFFICIENT, AND PROPER FACILITIES AT ALL TIMES FOR THE NOT SUCH ITEMS ARE ILLUSTRATED IN THE PROJECT DOCUMENTS. AND MAKE ANY APPLICABLE ADJUSTMENTS TO THE WIRE SIZES FOR VOLTAGE DROP. AS SPECIFIED HEREIN. INSPECTION OF THE WORK BY THE OWNER, ARCHITECT, AND ALL APPROPRIATE GOVERNMENTAL AND REGULATORY PANEL FEEDERS SHALL HAVE LESS THAN 2% VOLTAGE DROP AND BRANCH CIRCUITS AGENCIES. SHALL HAVE LESS THAN 3% VOLTAGE DROP. 2. ALL GROUNDING WIRE; LUGS, JUMPERS AND BUS SHALL BE COPPER. O �- 14. UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS OR OTHERWISE INSTRUCTED BY THE ARCHITECT, 3, ALL FEEDER AND BRANCH CIRCUITS SHALL CONTAIN AN EQUIPMENT GROUND WIRE. ELECTRICAL OUTLETS SHALL HAVE THE FOLLOWING MOUNTING HEIGHTS, DIMENSIONS ARE TO CENTER OF BOX 1..` NO METAL CONDUIT OF ANY KIND OR LENGTH SHALL BE USED AS THE EQUIPMENT UNLESS OTHERWISE NOTED: Q 0 U DRAWINGS BOXES GROUNDING CONDUCTOR. ��nn 1. PROVIDE OUTLET BOXES FOR ALL SWITCHES FIXTURES, RECEPTACLES AND ALL # v� 1. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE, BUT SHOW VARIOUS COMPONENTS WALL SWITCHES4. EQUIPMENT GROUNDING CONDUCTORS AND STRAPS SHALL BE SIZED IN ACCORDANCE " Z U OF THE SYSTEMS APPROXIMATELY TO SCALE AND ATTEMPT TO INDICATE HOW THEY OTHER OUTLET DEVICES. WALL CONVENIENCE RECEPTACLES 16 AFF TO BOTTOM OF BOX Q �n cls ARE TO BE INTEGRATED WITH OTHER PARTS OF THE BUILDING. DETERMINE EXACT WITH NEC. REFER TO FEEDER SCHEDULES FOR GROUND WIRE REQUIREMENTS WHICH WALL TELEPHONE OUTLETS 16" AFF TO BOTTOM OF BOX O co O MAY BE EXCEED THE NEC. ALL EQUIPMENT GROUNDING CONDUCTORS SHALL BE LOCATIONS BY REVIEW OF EQUIPMENT MANUFACTURERS DATA, BY JOB SITE 2. JUNCTION AND PULL BOXES SHALL HAVE SCREW -ON COVERS OR LOCKING HINGED WALL OUTLETS FOR WALL MTD. TELEPHONE O r MEASUREMENTS, PROVIDED WITH GREEN INSULATION EQUIVALENT TO THE INSULATION ON THE * .....1 Z BY CHECKING THE REQUIREMENTS OF OTHER TRADES, AND BY COVERS. NEMA 1 BOXES SHALL BE USED INDOORS. NEMA 3R BOXES WITH THREADED ASSOCIATED PHASE CONDUCTORS. MANUAL FIRE ALARM PULL STATIONS REVIEWING ALL CONTRACT DOCUMENTS. THE SIZE OF ELECTRICAL EQUIPMENT INDICATED HUBS SHALL BE USED OUTDOORS. FIRE ALARM SPEAKER/HORN 1'-0" BELOW CEILING, OR IN CEILING, AS REQUIRED W = ON THE DRAWINGS MAY BE BASED ON THE DIMENSIONS OF A PARTICULARINTERIOR BELLS BUZZERS HORNS 1'-0" BELOW CEILING OR IN CEILING AS REQUIRED 5. THE EQUIPMENT GROUNDING SYSTEM SHALL BE INSTALLED SO THAT ALL METALLIC " Z MANUFACTURER. WHILE OTHER LISTED MANUFACTURERS MAY BE ACCEPTABLE IT IS THE 3, BOXES SHALL BE SIZED IN ACCORDANCE WITH NEC ARTICLE 370. STRUCTURES ENCLOSURES RACEWAYS JUNCTION BOXES OUTLET BOXES CABINETS SPECIAL PURPOSE WALL OUTLETS 16 AFF TO BOTTOM OF BOX (OR HIGHER AS REQUIRED 0 U RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE IF THE EQUIPMENT THAT MACHINE FRAMES AND PORTABLE EQUIPMENT FRAMES OPERATE CONTINUOUSLY AT TO SERVE EQUIPMENT) CONTRACTOR PROPOSES TO FURNISH WILL FIT IN THE SPACE. 4. INTERIOR BOXES SHALL BE ONE PIECE, GALVANIZED STEEL CONSTRUCTION, GROUND POTENTIAL AND PROVIDE A LOW IMPEDANCE PATH FOR GROUND FAULT PUSH BUTTONS Q SUITABLE/LISTED FOR INTENDED USE. PROVIDE PLASTER -RINGS WHERE REQUIRED. CURRENTS. THE SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE, ADA VISUAL ALARM 80" AFF TO BOTTOM OF LENS OR 6" BELOW CEILING, a:I- 2. THE DRAWINGS ARE NOT INTENDED TO SHOW EXACT LOCATIONS OF CONDUIT, WIRE, INSTALL "GANGED" BOXES WHERE DEVICES ARE INDICATED TO BE GROUPED. WHICHEVER IS LOWER. ENTIRE LENS TO BE WITHIN 1 OR TO INDICATE ALL WIRE TERMINATORS, CONNECTORS, CONDUIT FITTINGS, BOXES, OR 6. GROUNDING CONDUCTORS SHALL BE CONTINUOUS AND NO SPLICING SHALL BE 80" to 96" AFF + ra. 0 SUPPORTS, BUT RATHER TO INDICATE DISTRIBUTION, CIRCUITRY, AND CONTROL. 5. EXTERIOR BOXES SHALL BE ONE PIECE PVC "UV PROTECTED". ALLOWED, 7 V J W # TOP OF BOX SHALL BE 48" AFF MAX. FOR WHEELCHAIR L 3. THE VARIOUS PHASES OF WORK. THE WORK SHALL BE LAID OUT SO THAT IT WILL 6. ALL CONDUIT CONNECTORS AND ENTRY HUBS SHALL BE INSULATED OR HAVE 7. PROVIDE COPPER GROUND BUSSES ON WALLS WHERE INDICATED ON THE DRAWINGS FRONTAL APPROACH AND 54" AFF MAX. FOR SIDE J BE CONCEALED IN FURRED CHASES AND SUSPENDED CEILINGS, ETC., IN FINISHED INSULATED BUSHINGS, AND WHERE SPECIAL GROUNDING NEEDS WILL ARISE, REFERENCE DETAIL ON DRAWING APPROACH, VERIFY EXACT HEIGHT WITH ARCHITECT. W PORTIONS OF THE BUILDING, UNLESS SPECIFICALLY NOTED TO BE EXPOSED. WORK FOR GROUND BUS AND CONNECTION REQUIREMENTS. SHALL BE INSTALLED TO AVOID CRIPPLING OF STRUCTURAL MEMBERS. ALL EXPOSED AFF = ABOVE FINISHED FLOOR WORK SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO THE LINES OF THE 8. WHERE REQUIRED, EMT CONNECTORS OR FLEXIBLE CONDUIT FITTINGS SHALL BE AFG = ABOVE FINISHED GRADE W BUILDING UNLESS OTHERWISE NOTED. WIRING DEVICES BONDED USING A CONDUIT LOCKNUT, T&B SERIES #106 OR EQUIVALENT, UL LISTED, 4. WHEN THE MECHANICAL AND ELECTRICAL DRAWINGS DO NOT GIVE EXACT DETAILS 1. PROVIDE A COMPLETE SYSTEM OF WIRING DEVICES PROPERLY WIRED, INCLUDING A 15. UNLESS SPECIFICALLY INDICATED ON THE ELECTRICAL DRAWINGS, OUTLETS LOCATED AT COUNTERS AND AS THE THE ELEVATION OF PIPE, CONDUIT AND DUCTS, PHYSICALLY ARRANGE THE SOLID GROUNDING CONNECTION. CABINETS SHALL BE MOUNTED AS SHOWN ON ARCHITECTURAL DETAILS AND ELEVATIONS, OR AS DIRECTED BY SYSTEMS TO FIT IN THE SPACE AVAILABLE. SPACES SHALL BE PRIORITIZED AS ARCHITECT, REQUIRED TO ALLOW FOR PROPER GRADES OF THE SYSTEMS INVOLVED. 2. UNDERWRITERS LABORATORIES: PROVIDE WIRING DEVICES WHICH ARE LISTED AND IDENEEIC TI N( SS 16. COORDINATE MOUNTING HEIGHTS AND DETAILS OF ALL OUTLETS (POWER, SIGNAL, ETC.) WITH ARCHITECTURAL LABELED BY UL, CASEWORK DRAWINGS PRIOR TO DIVISION 16 ROUGH -IN. PROVIDE COORDINATION DRAWINGS IN ACCORDANCE WITH 3, NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION: WIRING DEVICES SHALL 1. COMPLY WITH GOVERNING REGULATIONS AND REQUESTS OF GOVERNING AUTHORITIES DIVISION 16 SPECIFICATIONS WHERE CONFLICTS EXIST. OBTAIN APPROVAL FROM ARCHITECT BEFORE ELECTRICAL COMPLY WITH APPLICABLE NEMA STANDARDS. FOR IDENTIFICATION OF ELECTRICAL WORK. ROUGH -IN WHEN CONFLICTS ARISE, 4. DEVICE COLOR: WHITE UNLESS OTHERWISE NOTED, 2. PROVIDE NAMEPLATES/LABELS FOR ITEMS WHERE INDICATED AND/OR DESCRIBED IN 17, REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF ALL HVAC AND PLUMBING EQUIPMENT AND EQUIPMENT THESE SPECIFICATIONS. ROUGH -IN REQUIREMENTS SEAL 5. ACCEPTABLE: THE FOLLOWING MANUFACTURERS WILL BE ACCEPTABLE PROVIDING r 1. THE CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE INSTALLATION OF ALL THEY MEET THE PROJECT SPECIFICATIONS: COPPER WIRING DEVICES, ARROW -HART, 3. ALL ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE LABELED. 18. CIRCUITING ®oma°° ��� ��/ EQUIPMENT SHOWN ON THE DRAWINGS. ALL MANUFACTURERS SPECIFICATIONS SHALL HUBBELL, LEVITON, LUTRON, WOODHEAD INDUSTRIES, A. BRANCH CIRCUITING IS SCHEMATIC IN NATURE AND IS INTENDED TO INDICATE CIRCUIT LOADING °��j:'�s BE FOLLOWED IN REGARDS TO THE INSTALLATION OF ALL EQUIPMENT. ANY SPECIAL 4. LABELS SHALL BE ENGRAVED PHENOLIC TAGS WITH MINIMUM .5" TEXT HEIGHT. AND CONTROL, NOT METHODS OF INSTALLATION. REFER TO SPECIFICATIONS FOR METHODS OF MANUFACTURER'S REQUIREMENTS NECESSARY FOR PROPER OR SAFE INSTALLATION OF 6. STANDARD CONVENIENCE OUTLET: 20A/125V/2 POLE/3 WIRE DUPLEX NEMA 5-20R. DYMO (OR EQUIVALENT) LABELS SHALL NOT BE USED, INSTALLATION AND MATERIALS. ' pg EQUIPMENT REGARDLESS OF WHETHER THE AFOREMENTIONED SPECIAL REQUIREMENTS DUPLEX RECEPTACLE, RECEPTACLE FACE SHALL BE HIGH -IMPACT RESISTANT. NYLON 5. COLOR CODE: ALL POWER EQUIPMENT- BLUE FIELD WITH WHITE LETTERS. ARE INDICATED ON THE DRAWINGS, SHALL BE AT THE EXPENSE AND RESPONSIBILITY BODY SHALL BE THERMOPLASTIC POLYESTER. MOUNTING STRAP SHALL WARP B. WHERE WIRE SIZE AND CONDUIT SIZE IS NOT INDICATED ON THE DRAWINGS AND/OR PANEL TATE OF OF THE CONTRACTOR. COMPLETELY AROUND RECEPTACLE BODY AND HAVE INTEGRAL , RIVETLESS GROUNDING SCHEDULES, REFER TO SPECIFICATIONS AND THE NEC FOR MINIMUM SIZE REQUIRED. CONTACTS. THE RECEPTACLE GROUNDING CONTACTS ARE FORMED DIRECTLY OUT OF 6. TAGS SHALL BE PERMANENTLY AFFIXED WITH SCREWS, ADHESIVES ARE NOT �`i�,� 2. THE DIVISION 16 INSTALLER IS RESPONSIBLE FOR THE PURCHASE (OTHER 1HAN THE BACKSTRAP METAL. THEY SHALL NOT BE SEPARATE PIECES AFFIXED TO THE ACCEPTABLE. C. BRANCH CIRCUITS ON THE DRAWINGS ARE GENERALLY NOT SHOWN GROUPED IN SINGLE '',�J OWNER SUPPLIED EQUIPMENT), RIGGING, ERECTION, INSTALLATION AND FUNCTIONAL BACKSTRAP. RACEWAYS AND SHARING COMMON NEUTRALS, HOWEVER, GROUPING IS ALLOWED UNDER CERTAIN BrlTr OPERATION OF ALL ELECTRICAL EQUIPMENT EXCEPT WHERE NOTED, 7. ALL POWER RECEPTACLES SHALL HAVE CIRCUIT ID LABEL, THIS LABEL SHALL BE A CONDITIONS. REFER TO DIVISION 16 SPECIFICATIONS FOR REQUIREMENTS. 7. GROUND FAULT CIRCUIT INTERRUPTERS: PROVIDE U.L LISTED GROUND FAULT CLEAR LAMINATED MYLAR TYPE TAPE, WITH .25" BLACK LETTERING, LABEL SHALL BE CA79 3. ALL LOCATIONS OF EQUIPMENT AND FIXTURES ARE APPROXIMATE AND MAY REQUIRE CIRCUIT INTERRUPTER RECEPTACLES FOR PERSONNEL PROTECTION, WHICH OTHERWISE APPLIED HORIZONTAL POSITION ON THE TOP OF RECEPTACLE FACEPLATE. D. THE DRAWINGS GENERALLY INDICATE QUANTITY OF CONDUCTORS ON BRANCH CIRCUIT HOME RUNS MINOR ADJUSTMENT TO SUIT FIELD CONDITIONS, ALL ADJUSTMENTS SHALL BE MEET THIS SPECIFICATION, WHERE REQUIRED. DEVICES SHALL BE 20A, AND SHALL ONLY. ELSEWHERE WITHIN CIRCUITS, PROVIDE QUANTITY OF CONDUCTORS AS NEEDED TO REVISIONS SUBMITTED TO THE ENGINEER FOR APPROVAL. HAVE A DEDICATED INSULATED GREEN GROUND WIRE RUN CONTINUOUS (UNSPLICED) ACCOMPLISH CIRCUITING AND SWITCHING REQUIREMENTS SHOWN. BETWEEN THE DEVICE AND THE GROUND BUS. REV � DATE DESCRIPTION 19. COMPLETE SYSTEMS: PROVIDE LABOR, MATERIALS, EQUIPMENT, AND TRANSPORTATION TO RECEIVE, INSTALL, 8. WALL SWITCHES: 20A -120-277V AC CONTACTS. TOGGLE TYPE, QUIET ACTION WITH ADJUST, AND PUT INTO OPERATION COMPLETE ELECTRICAL SYSTEMS IN ACCORDANCE WITH THE INTENT OF THE Q - - SEPARATED SCREW TERM FOR THE GROUND WIRE. SCREWLESS PUSH -IN WIRING TERM CONTRACT DOCUMENTS. PROVIDE PRODUCTS NOT MENTIONED BUT OBVIOUSLY NECESSARY AND INCIDENTAL TO SHALL NOT BE USED. PROVIDE SINGLE POLE, SINGLE THROW, UNLESS DRAWINGS THE COMPLETION OF THIS WORK. INDICATE WAY, 4 -WAY, DOUBLE POLE, KEY OPERATED, SPDT MOMENTARY, OR ANY 20. SCOPE: WORK SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: MECHANICAL WORK AS REQUIRED RACEWAY OTHER SPECIAL FEATURES. FOR COORDINATION, POWER DISTRIBUTION, FIRE ALARM SYSTEM, AND INSTALLATION OF MATERIALS. ® - 1. MINIMUM CONDUIT SIZES SHALL BE 3/4". 9, SWITCHES FOR SPECIAL PURPOSE: SPECIAL SWITCHES USED FOR DISCONNECTION 21. UTILITIES: COORDINATE WITH ALL UTILITY SERVICES. NOTIFY UTILITIES OF COMMENCEMENT OF WORK. MAKE 0 - PURPOSES (SMALL APPLIANCES, ETC.) SHALL BE RATED AS SPECIFIED OR REQUIRED. ALL ARRANGEMENTS FOR TEMPORARY SERVICES, PROVIDE ALL WORK AND MATERIALS NECESSARY TO COMPLY WITH © - 2. PROVIDE COMPLETE RACEWAY SYSTEMS FOR ALL WIRING UNLESS OTHERWISE NOTED. ALL UTILITY REGULATIONS AND REQUIREMENTS. THIS INCLUDES FEEDERS, BRANCH CIRCUITS, CONTROL WIRING, AND SYSTEMS WIRING. 7 _ - LOCATIONS OF CONDUITS SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE AND 22. EXPERIENCE: ALL WORK DONE SHALL BE PERFORMED BY QUALIFIED ELECTRICIANS, UNDER THE SUPERVISION A - - ALL LOCAL AND STATE REGULATIONS. AND DIRECTION OF A SUPERINTENDENT HAVING SUCCESSFUL EXPERIENCE INSTALLING AND SUPERVISING EQUIPMENT ENCLOSED SWITCHES AND SYSTEMS OF SIMILAR TYPE AND SIZE AS INDICATED BY CONTRACT DOCUMENTS. - - 3. TRANSITIONS FROM CONCRETE ENCASEMENT: WHERE PVC CONDUIT IS USED FOR DATE 03.16.17 RUNS UNDERGROUND OR IN SLABS, AS OUTLINED HEREIN, A CONVERSION TO RIGID 1, PROVIDE HEAVY DUTY TYPE ENCLOSED SWITCHES, SQUARE. D CLASS 3110 TYPE HD. 23. REGULATIONS: ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH CURRENT RULES, REGULATIONS, AND STEEL "ELL" SHALL BE USED TO EXIT EARTH OR ENCASEMENT. PROVIDE SWEEPING SWITCHES SHALL HAVE EXTERNALLY OPERATED HANDLES WITH PROVISIONS FOR PAD INDUSTRY STANDARDS OF THE N.E.C., UL, IPCEA, NEMA, NFPA, OSHA, NATIONAL ELECTRICAL SAFETY CODE, AND DRAWN BY B.M.A. ELBOWS WITH LARGEST POSSIBLE RADIUS FOR ALL CHANGES OF DIRECTION. LOCKING IN THE OFF OR ON POSITION. PROVIDE NEMA 3R OR 4X STAINLESS STEEL ANY LOCAL CODES, LAWS, ADA OR ORDINANCES. IN THE EVENT THAT A DISCREPANCY IS FOUND IN THE UNITS AS INDICATED ON THE DRAWINGS. CONTRACT DOCUMENTS THE ENGINEER SHALL BE N011FIED IMMEDIATELY. DESIGNED BY B.M.A. 4. PROVIDE AN INSULATED -THROAT METALLIC OR ALL -PLASTIC BUSHING ON ALL EMT, APPROVED BY B.T.B. IMC, AND RIGID METALLIC RACEWAY STUBS AND TERMINATION IN PANELS, 2. WHERE REQUIRED: PROVIDE ALL ENCLOSED DISCONNECT SWITCHES INDICATED ON 24. COSTS AND CONDITIONS: EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS IN THEIR SWITCHBOARDS, CABINETS, PULL BOXES, JUNCTIONS BOXES, GUTTERS, AND OTHER THE DRAWINGS. WHERE A CIRCUIT SERVES A MOTOR, MOTOR CONTROLLER, FIXED ENTIRETY, SURVEY THE PROJECT AND BECOME FAMILIAR WITH EXISTING CONDITIONS AND SCOPE OF WORK. ALL PROJECT NUMBER 17119-00 ENCLOSURES, ELECTRIC SPACE HEATING UNIT, OR APPLIANCE AND A LOCAL DISCONNECT SWITCH IS COSTS SUBMITTED SHALL BE BASED ON A THOROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY NOT INDICATED ON THE DRAWINGS, PROVIDE A LOCAL DISCONNECT UNLESS ONE OF ADDITIONAL COSTS DUE TO FAILURE TO COMPLY WITH THIS REQUIREMENT SHALL BE THE RESPONSIBILITY OF THE DRAWING 5. CEILING GRID SHALL NOT SUPPORT ANY CABLE OR RACEWAY. THE NEC EXCEPTIONS PERTAIN, CONTRACTOR, E-1 1 0 2 0 3 ■ 4 0 5 0 6 0 7 m 8 0 9 0 10 ■ 11 m 12 0 13 ■ 1Ll 0 15 ■ A ■ B ■ C ■ D ■ E F e , K ■ A B ■ C ■ D ■ E r F G i -I ■ J ■ K 1 J 2 ■ 3 ■ 4 ■ 5 ■ 6 ■ 7 ■ B ■ 9 ■ '10 ■ 11 ■ 12 ■ 13 ■ 14 15 ■ n 1 ' 2 3 ■ 4 ' 5 ' 6 7 ■ 8 ' 9 ■ 10 ■ 11 ■ 12 ■ 13 14 15 ■ BUHOLTZ PROFESSIONAL ENGINEERING, INC. 154 TUskawilla Rd., Ste. 1380 Winter Springs FL 32708 Ph 407-327-3300 CA 00009600 THESE PLANS AND DESIGNS SHOWN HEREON REMAIN THE PROPERTY OF BUHOLTZ PROFESSIONAL ENGINEERING, INC. THEIR USE WITHOUT WRITTEN LICENSE IS PROHIBITED. COPYRIGHT BUHOLTZ PROFESSIONAL ENGINEERING, INC. ALL RIGHTS RESERVED m w 3: o� a� u J bo aCT— U U w I w SEAL ��sr�arrrrri QU�y°�r r ' SATE OF -off � • , F p`Q ; w�- Bri'rnr ,©ItZ, PE CA 979 REVISIONS REV # DATE DESCRIPTION Al — — A — — Q ® — — A — — © ` A7 — 0 — — DATE 03.16.17 DRAWN BY B.M.A. DESIGNED BY B.M.A. APPROVED BY B.T.B. PROJECT NUMBER 17119-00 DRAWING E--2 A ■ 0 ■ C D E ■ F G ■ ■ N K ■ 0 3: Q 00 Z � 04 d 0 m z O�� zcl) a w J i� m w 3: o� a� u J bo aCT— U U w I w SEAL ��sr�arrrrri QU�y°�r r ' SATE OF -off � • , F p`Q ; w�- Bri'rnr ,©ItZ, PE CA 979 REVISIONS REV # DATE DESCRIPTION Al — — A — — Q ® — — A — — © ` A7 — 0 — — DATE 03.16.17 DRAWN BY B.M.A. DESIGNED BY B.M.A. APPROVED BY B.T.B. PROJECT NUMBER 17119-00 DRAWING E--2 A ■ 0 ■ C D E ■ F G ■ ■ N K ■ A i ■ B C D J: ■ E ■ F ■ ■ D J: ■ E ■ F G ■ H ■ ■ ■ 1) CONDUCTORS ARE SIZED PER N.E.C. TABLE 310.15(8)(16) 2) ALL PVC RACEWAY SHALL BE SCHEDULE 40 WITH SCHEDULE 80 LONG RADIUS BENDS FOR #250 AWG AND LARGER CONDUCTORS G ■ H ■ ■ ■ K ■ 1 2 ■ 3 ■ 4 ■ 5 6 ■ 7 ■ 8 9 ■ 10 ■ 11 ■ 12 ■ 13 ■ 14 ■ 15 ■ l A X A 1 J 1) CONDUCTORS ARE SIZED PER N.E.C. TABLE 310.15(8)(16) 2) ALL PVC RACEWAY SHALL BE SCHEDULE 40 WITH SCHEDULE 80 LONG RADIUS BENDS FOR #250 AWG AND LARGER CONDUCTORS ■ K ■ 1 2 ■ 3 ■ 4 ■ 5 6 ■ 7 ■ 8 9 ■ 10 ■ 11 ■ 12 ■ 13 ■ 14 ■ 15 ■ l A X A 1 FEEDER SCHEDULE 1) CONDUCTORS ARE SIZED PER N.E.C. TABLE 310.15(8)(16) 2) ALL PVC RACEWAY SHALL BE SCHEDULE 40 WITH SCHEDULE 80 LONG RADIUS BENDS FOR #250 AWG AND LARGER CONDUCTORS EQUIPMENT =__ EXISTING UTILITY TRANSFORMER F.L.A. BREAKER POLES NEUTRAL SETS WIRE ( Y-,;�-Y 1 COLUMN CU CONDUIT LENGTH VOLTAGE DROP # , I � I i I I AL EMT PVC 40 PVC 80 SPRAY BOOTH FAN CONTROL PANEL 208 — I I r ;':z 1 20 3 YES 1 4 #10 EXISTING FEED THROUGH METER I 60° CU 3/4" 3/4" 3/4" 110 I I I SPRAY BOOTH LIGHTING 120 10.0 20 1 YES I I I r-'-4 2 #8 #8 60' CU 3/4" EXISTING 600A DISCONNECT 3/4" 110 2.29% B.M.A. DESIGNED BY I, I W APPROVED BY J PROJECT NUMBER 17119-00 I I I E-3 I I I 600A M.L.O. aaanuammmmmnm9 ammmm:aammmmm mmmattammamanmst ma ammummmmmma� mammamammmmmn mmarummamamaaa rmmmmmmammama mamammmammaaa caa�maamammmamm�ammvaaaammmmzj EXISTING PANEL 'MDP' vwr■a a a armUlu mmn1v b, 400A I I I I I I I I b, b•. �, 175A, JOA I I I I I I I I I I I I I I t I b. JOA I I I I I I I I b� y, JOA I I I I I I I I b. b� y. JOA, JOA I I I i I I I I I I I I I I b, 4, JOA I I I I I I I b� y, 20A I I I I I I I I I I I I I �Iy I I I I 1 I I I I I I I I I I I I I 1 I �Iy I I I I I I I I I I I I I I I I I I I I I �iy I I I I I I I I I i I 1 I I I 1 1 EXISTING i EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 2771480V PANEL TABLE SAW I i I TABLE SAW PLANER ACCU 12 AHU 12 ACCU /1 AHU /I I I I I I i n _ EXISTING TRANSFORMER 'LDP' ,r=-Y-� 112.5 kVA 480V PRIMARY (' 1 120/208V SECONDARY I I -I- I =" t I I I I I I 400A RC.B. EXISTING PANEL 'LDP' ............ n m v a a m m a m m a a a a m m m m a a m m m m a m m■ m a■ m m m m a m m a a m a n a a a m m m m r. m a m a n m a a n m a m a m m m m ............... �. 200A, I I I I I 200A I I I I I I NOTE: I I I 1 I 225A M.L.O. I I 1 1 I I � 225A tif.L.O. EXISTING 12 MONTH PEAK READING ON THE ' Aw0Uamnammmmnm ma mss ammmmam.. EXISTING PANEL 'RPI'' mmmmmammammainmaana0waaaaa �..m.mmmammmmmmmmammaamamm■� EXISTING PANEL 'RP2' EXISTING SERVICE PER FLORIDA POWER & 20A 3P > 20A 1 P LIGHT IS 60kW. 60kW AT 480V 30 = 72 AMPS. PROVIDE PER THE ABOVE LOAD CALCULATION IT IS PROVIDE A NEW 20A 3P CIRCUIT A NEW 20A 1P CIRCUIT ASSUMED THAT EXISTING PANEL 'RP1' IS BREAKER IN EXISTING SPACES, BREAKER IN EXISTING SPACE. CONTRACTOR SHALL MOVE EXISTING LIGHTLY LOADED AND IS CAPABLE OF CIRCUIT BREAKERS IN PANEL TO ACCOMMODATING THE NEW LOADS, ACCOMMODATE THE NEW 20A 3P CIRCUIT BREAKER. PROVIDE A NEW 30A 3P 250V PROVIDE A NEW 20A 1P 250V NON-FUSED NEMA 1 DISCONNECT NON-FUSED NEMA 1 DISCONNECT SWITCH AT SPRAY BOOTH LOCATION IF SWITCH AT SPRAY BOOTH LOCATION IF DISCONNECTING MEANS ARE NOT DISCONNECTING MEANS ARE NOT PROVIDED WITH THE SPRAY BOOTH, PROVIDED WITH THE SPRAY BOOTH, TO NEW TO NEW SPRAY BOOTH SPRAY BOOTH CONTROL PANEL LIGHTING EQUIPMENT FEEDER SCHEDULE 1) CONDUCTORS ARE SIZED PER N.E.C. TABLE 310.15(8)(16) 2) ALL PVC RACEWAY SHALL BE SCHEDULE 40 WITH SCHEDULE 80 LONG RADIUS BENDS FOR #250 AWG AND LARGER CONDUCTORS EQUIPMENT VOLTAGE F.L.A. BREAKER POLES NEUTRAL SETS WIRE GND COLUMN CU CONDUIT LENGTH VOLTAGE DROP # SIZE AL EMT PVC 40 PVC 80 SPRAY BOOTH FAN CONTROL PANEL 208 15.0 20 3 YES 1 4 #10 #10 60° CU 3/4" 3/4" 3/4" 110 1.76% SPRAY BOOTH LIGHTING 120 10.0 20 1 YES 1 2 #8 #8 60' CU 3/4" 3/4" 3/4" 110 2.29% 1 ■ 2 ■ 3 4 ■ 5 ■ 6 ■ 7 8 ■ 9 10 ■ 11 ■ 12 ■ 13 ■ 14 ■ 15 ■ BUHOLTZ PROFESSIONAL ENGINEERING, INC. 154 Tuskawilla Rd., Ste. 1350 Winter Springs FL 32708 Ph 407-327-3300 CA 00009600 THESE PLANS AND DESIGNS SHOWN HEREON REMAIN THE PROPERTY OF BUHOLTZ PROFESSIONAL ENGINEERING, INC. THEIR USE WITHOUT WRITTEN LICENSE IS PROHIBITED. COPYRIGHT BUHOLTZ PROFESSIONAL ENGINEERING, INC. ALL RIGHTS RESERVED Y �✓ Ne cr 0 3:: B q3 Q 00 z REV # O DESCRIPTION A - - QN QC7 0Q A VJ - A U0 - co A O �. � z� o0 O - A vJ Q Q + - - � IL DATE Q DRAWN BY B.M.A. DESIGNED BY W APPROVED BY J PROJECT NUMBER 17119-00 DRAWING E-3 Q I.ri: 0 Q rW V, J � Q U 1a : f U W .J W SEAL �✓ `o��P C1 �Q r N . 57979 �. STT OF4 B q3 REVISIONS REV # DATE DESCRIPTION A - - A - - A - - A - - A - - A - - A - - DATE 03.16.17 DRAWN BY B.M.A. DESIGNED BY B.M.A. APPROVED BY B.T.B. PROJECT NUMBER 17119-00 DRAWING E-3 A ■ ■ ■ H ■ J ■ K Revision ❑ ' City of Sanford Response to Comments ❑ OCT 2 ,j 201-7 Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 t . _ .---- --- Email: building@sanfordfl.gov Permit # Submittal Date Project Address: _ E� r� �,v ro,R.i-, Contact• .... t .. __.. k A-,--,) 5o,--.).._. Ph: ��� -� �(d ` �L� 0 Fax: Email: ``�f5c-U l" , %15� C� C• �0�✓1 1 ulrn Trades encompassed in revision: ISI Building ❑ Plumbing ❑ Electrical NJ M- echanical ❑—L-ife Safety ❑ Waste Water ZOU General description of revision: s 'CVi=( N(.1 ROUTING INFORMATION Department Approvals ❑ Utilities ❑ Waste Water _ ❑ Planning _ ❑ Engineering _ ❑ Fire Prevention ❑/Building la -..Z6 M 11 12 13 ■ 14 ■ 15 ■ 0 A D G 1 2 ■ 3 r 4 5 ■ 6 ■ 7 r g r 9 ■ 10 11 12 13 ■ 14 ■ 15 ■ 0 A D C= 1-9 D D C= 1-9 ■ . J 1 E2 ■ 3 ■ 4 5 ■ 6 ■ 7 ■ 8 ■ 9 ■ 10 0 11 ■ 12 ■ 13 ■ '14 ■ 15 ■ G ■ . J 1 E2 ■ 3 ■ 4 5 ■ 6 ■ 7 ■ 8 ■ 9 ■ 10 0 11 ■ 12 ■ 13 ■ '14 ■ 15 ■