Loading...
HomeMy WebLinkAbout211 Towne Center Blvd 17-2777; interior alterationi �> CITY OF SANFORD BUILDING & FIRE PREVENTION 20VI 1 PERMIT APPLICATION bL Application No: W' Documented Construction Value: $ 51,186.18 Job Address: 1-Q4 Towne Center Blvd, Unit 211 Historic District: Yes ❑ No ❑ Parcel ID: 29-19-30-503-0000-0020 Residential ❑ Commercial Type of Work: New ❑ Addition ❑ Alteration ® Repair ❑ Demo ❑ Change of Use ❑ Move ❑ t Description of Work: Interior Renovation to accomodate commercial office space _ Plan Review Contact Person: Phone: 386-341-6232 Rachelle Kirton 'Title: r VP Fax: 877-236-0755 Email: rachellekirton@kirtonenterprises.corn Property Owner Information 2��, meq(_ &_;2-7 I - Name MSKP Gateway LLC Phone: Street: 4500 PGA BLVD, STE 400 Resident of property? City, State Zip: Palm Beach Gardens, FL 33418 Contractor Information Name Kirton Enterprises, Inc Phone: 386-341-6232 Street: 1630 Tomoka Farms Rd Fax: 877-236-0755 City, State Zip: Port Orange, FL 32128 State License No.: CGC 1506176 Architect/Engineer Information Name: JWB Architects Phone: 407-298-5020 Street: 2295 South Hiawassee Rd, Suite 304 Fax: City, St, Zip: Orlando, FL 32835 E-mail: mpowers@jwb-arch.com Bonding Company: N/A Mortgage Lender: N/A Address: _ Address: WARNINGTO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT' MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRSTINSPECTION. IF YOU IN'T'END TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMNIENCEMENT, Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, ttn-naces, boilers, heater's, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5"i Edition (2014) Florida Building Code Pennit Application RcviscJ: June 31J, 2U 15 N. TOWNE BLVD. i i C Ivi A r SCALE: NOT TO SCALE NORTH )IN—i•-�`'L)1�d�R o �lE A A pL!'','tArl" IFS>U7~Q SHALL BE C.UN•�TRU GANGEL, AI:rE� OR ET LICEr!.;E rU wFtUC_EC) Nlr(H THE \N AND NUT A AUTHOR TY'r{) \�►Qi.A°f c, OF'rHE'ri:;�, •I`.iGAL � ,4Ut: ANY Ut THE r�rtO\jIS UN (;f.)r) S, t,I�'�i' SHAH UFFu%IAL F1 tUM rH �AFTEHV�t\!'( r} I(_ C ILU (if:,)�IfiWCaACORi iEG1*1(- S��•)N`StOf-THIS CODE . COI`IS+! hUG'rl;)N OR VIA I ) PERMIT SHEET I NDEX COVER SHEET ARCHITECTURAL A101 EXISTING/DEMO FLOOR PLAN A102 EXISTING REFLECTED CEILING PLAN A200 LIFE SAFETY PLAN A201 NEW FLOOR PLAN A202 REFLECTED CEILING PLAN A401 WALL SECTIONS & DETAILS A601 ENLARGED RESTROOM PLAN & ELEVATIONS 2295 S. FIIAWAS3EE RD. Q SUI"FE 3.04 U ORLANDO, FLORIDA 32835 Q) PH:407,298-5020 FD U) FX:407.298-5030 ELECTRICAL o �J (n cn um c>� La o U � a E200 LIGHTING DEMO & RENO PLANS PROJECT SQUARE FOOTAGE: TOTAL SQUARE FOOTAGE -- 2797 SQFT CONSTRUCTION TYPE: EXISTING. -TYPE 2B SPRINKLERED TYPE 2B SPRINKLERED OCCUPANCY. B BUSINESS APPLICABLE BUILDING CODES": • 2014 FLORIDA BUILDING CODE 2014 FLORIDA EXISTING BUILDING CODE • 2014 FLORIDA ACCESSIBILITY CODE • 2014 FLORIDA MECHANICAL CODE 2014 FLORIDA PLUMBING CODE 2014 FLORIDA FIRE PREVENTION CODE, NFPA 1 and NFPA 101 2012 Fifth. ed. 2011 NATIONAL ELECTRIC CODE s✓ E Q U Q) FD U) ELECTRICAL o �J (n cn a) c>� E100 ELECTRICAL LEGEND NOTES & SPECS o U � a E200 LIGHTING DEMO & RENO PLANS v E300 POWER RENOVATION PLANS o (3) PLUMBING P201 PLUMBING PLAN o n Nil D 4-1 v) (-� Q) o 70 a) !6! 0. • � 2 cn bb cd iL o -0 L- Ai C .0 c 3 (j3 1rjLu L!J ry 170 Cf3 City of Sanford Oil and Grease Programi�y` ` 1D Initials & Date u) LA 0 N (D cn C[) OU (ll �) p CODE INFORMATION 1, (i3 U � N PROJECT SQUARE FOOTAGE: TOTAL SQUARE FOOTAGE -- 2797 SQFT CONSTRUCTION TYPE: EXISTING. -TYPE 2B SPRINKLERED TYPE 2B SPRINKLERED OCCUPANCY. B BUSINESS APPLICABLE BUILDING CODES": • 2014 FLORIDA BUILDING CODE 2014 FLORIDA EXISTING BUILDING CODE • 2014 FLORIDA ACCESSIBILITY CODE • 2014 FLORIDA MECHANICAL CODE 2014 FLORIDA PLUMBING CODE 2014 FLORIDA FIRE PREVENTION CODE, NFPA 1 and NFPA 101 2012 Fifth. ed. 2011 NATIONAL ELECTRIC CODE s✓ E Q U Q) FD U) o (n cn a) c>� o U w 0 EXISTING/DEM0 FLU"OR PLAN �01 SCALE: 1/4" = 1'-0" NORTH Project No. 17-049 Sheet No. NORTH i 5 L A. ALL DEMOLITION WORK REQUIRED IS NOT LIMITED TO THAT INDICATED ON THESE PLANS. THE INTENT IS TO REMOVE ALL MECHANICAL, ELECTRICAL. PLUMBING, COMMUNICATIONS, AND ARCHITECTURAL ITEMS AS INDICATED AND AS NECESSARY TO FACILITATE NEW CONSTRUCTION, B. ALL DIMENSIONS ARE FROM FACE OF STUD, OR FACE OF MASONRY, OR FACE OF CONCRETE WALL. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT/DESIGNER. DO NOT SCALE DRAWINGS. C. PATCH SURFACES TO MATCH EXISTING ADJACENT FINISHES. REFER TO OWNER SPECIFICATIONS FOR CUTTING/PATCHING DETAILS. D. ALL ABANDONED MECHANICAL , PLUMBING, AND ELECTRICAL PIPING, RACEWAYS, AND DUCTWORK ARE TO BE REMOVED TO A POINT BELOW EXISTING FLOOR SLAB, BEHIND WALLS, AND AS CLOSE TO CUTTING/PATCHING DETAILS. DEM00" PLAN NOTES: 01 TBD LEGEN: II II ALL EXISTING LIGHT FIXTURES TO BE RELOCATED LL— — —11 ALL EXISTING MECHANICAL DIFFUSERS TO BE RELOCATED EX Xx DEMOLITION PLAN NOTES, SEE DEMO PLAN ARCHITECTS LIC. i# AA26001266 2295 S. HIAWASSEE RD. SUITE 304 ORLANDO, FLORIDA 32835 PH:407.298-5020 FX:407.298-5030 Owner: Kent Kirton W U) Q) O �l U CL N (1) LJ Ll L J O L] L -1 O L --j 0- E L L W E f -- O � Q) W CLI •tn 10 kk ism O 70 i:� m S L- LL ( m Q) � CCi O v Q CD a -0Q) v v U CO v i— o �, co cv � � v E o � Q) v o _0 7a-) cn v 4- O V) v E O U v A. ALL DEMOLITION WORK REQUIRED IS NOT LIMITED TO THAT INDICATED ON THESE PLANS. THE INTENT IS TO REMOVE ALL MECHANICAL, ELECTRICAL. PLUMBING, COMMUNICATIONS, AND ARCHITECTURAL ITEMS AS INDICATED AND AS NECESSARY TO FACILITATE NEW CONSTRUCTION, B. ALL DIMENSIONS ARE FROM FACE OF STUD, OR FACE OF MASONRY, OR FACE OF CONCRETE WALL. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT/DESIGNER. DO NOT SCALE DRAWINGS. C. PATCH SURFACES TO MATCH EXISTING ADJACENT FINISHES. REFER TO OWNER SPECIFICATIONS FOR CUTTING/PATCHING DETAILS. D. ALL ABANDONED MECHANICAL , PLUMBING, AND ELECTRICAL PIPING, RACEWAYS, AND DUCTWORK ARE TO BE REMOVED TO A POINT BELOW EXISTING FLOOR SLAB, BEHIND WALLS, AND AS CLOSE TO CUTTING/PATCHING DETAILS. DEM00" PLAN NOTES: 01 TBD LEGEN: II II ALL EXISTING LIGHT FIXTURES TO BE RELOCATED LL— — —11 ALL EXISTING MECHANICAL DIFFUSERS TO BE RELOCATED EX Xx DEMOLITION PLAN NOTES, SEE DEMO PLAN ARCHITECTS LIC. i# AA26001266 2295 S. HIAWASSEE RD. SUITE 304 ORLANDO, FLORIDA 32835 PH:407.298-5020 FX:407.298-5030 Owner: Kent Kirton W U) Q) O �l U CL N (1) O � O 0- E -a v L W E f -- O � Q) W CLI •tn 10 kk ism O 70 i:� m S L- LL ( m Q) � CCi O v Q CD a -0Q) v v U CO v i— o �, co cv � � v E o � Q) v o _0 7a-) cn v 4- O V) v E O U v I EXISTING 1 HR TENANT SFPARATION LIFE SAFETY PLAN 1,200 SCALE: 1/4" ® EXIT SIGNAGE & LIGHT }®+ TWO SIDED EXIT SIGNAGE & LIGHT W/DIRECTIONAL ARROW I U-1111 MIN I SEPARATION WALL TO REMAIN AS MARKED IN FIELD 01 EXISTING FIRE EXTINGUISHER LIFE SAFETY m 1. EXIT LIGHTS SHALL BE PROVIDED AT ALL DOORS ALONG THE EGRESS PATH. 2. EMERGENCY LIGHTING SHALL BE PROVIDED AS REQUIRED BY CODE. 3. U.Q.N., ALONG THE EGRESS PATH, EACH SINGLE SWINGING DOOR SHALL PROVIDE 33" MIN. CLEAR WHEN THE DOOR IS FULLY OPEN AND SHALL HAVE AN EGRESS CAPACITY OF 165 PEOPLE. 4. U.O.N., ALONG THE EGRESS PATH, EACH DOUBLE SWINGING DOOR SHALL PROVIDE 66" MIN. CLEAR WHEN THE DOORS ARE FULLY OPEN AND SHALL HAVE AN EGRESS CAPACITY OF 340 PEOPLE. 5. ALL DOOR HARDWARE SHALL MEET ALL APPLICABLE CODE REQUIREMENTS FOR EGRESS AND HANDICAP ACCESSIBILITY. 6. ALL DIMENSIONS SHOWN ON THIS PLAN ARE MINIMUM CLEAR DIMENSIONS. 7. GC SHALL INSTALL A KNOX BOX AT THE MAIN ENTRANCE. GC SHALL COORDINATE THE EXACT LOCATION, MOUNTING HEIGHT, AND TYPE WITH THE LOCAL FIRE OFFICIAL. 9. INTERIOR DECOR DRAWINGS PREPARED AND SUBMITTED FOR PERMIT BY OTHERS. SEE DRAWINGS PREPARED BY SEATING CONCEPTS FOR DECOR AND SEATING COMPONENT INFORMATION. WITH DOOR 10. 4 GENERAL NOTE: 11. THIS CODE COMPLIANCE PLAN IS NOT ISSUED SOLEY FOR THE USE OF CODE REVIEW OFFICIALS. ALL CONTRACTORS REGARDLESS OF TRADE ARE RESPONSIBLE FOR CONSTRUCTING THE BUILDING AS DESCRIBED ABOVE. THIS INCLUDES BUT IS NOT LIMITED TO FIRE DAMPERS, FIRE RATINGS ON DOORS, FIRE RATINGS ON ACCESS DOORS, DOOR CLOSERS, FIRE STOPPING AND OTHER COMMON DEVICES USED TO MAINTAIN THE REQUIRED FIRE RATING OF THE ASSEMBLY. UODE uumPLIANCE. OCCUPANT LOAD PER FBC 2014, NFPA 2009 (TABLE 7.3.1.2): BUILDING DATA: BUSINESS NUMBER OF STORIES: ONE STORY 1 OCCUPANT PER 100 NET SF. 2,994 NSF / 100 NSF PER PERSON: TOTAL OCCUPANTS = 30 OCCUPANTS PREVIOUS OCCUPANCY TYPE: B PROPOSED OCCUPANCY TYPE: BUSINESS (B) PER NFPA 101, TABLE 7.3.1.2, TOTAL OCCUPANT LOAD = 30 OCCUPANTS CONSTRUCTION TYPE: MEANS OF EGRESS: PROPOSED: ALTERATION TYPE - LEVEL 2 EXISTING BUILDING: TYPE 213, SPRINKLERED MAXIMUM ALLOWABLE TRAVEL DISTANCE: 200 FEET PER TABLE 1016.1 MAXIMUM PROVIDED TRAVEL DISTANCE: 95 FEET - 4 INCHES ACTUAL AREA MAXIMUM ALLOWABLE DEAD END CORRIDOR LENGTH: 25 FEET 2994 SQ. FT. EGRESS WIDTH PER PERSON SERVED: .2 INCHES 30 OCCUPANTS X .2" = 6" REQUIRED (144" PROVIDED) ACCESS TO ACCESSIBLE DRINKING FOUNTAIN OWNER WILL PROVIDE WATER FOR PUBLIC CONSUMPTION 1 FLOOR PLAN A201 SCALE: 1/4" = 1'-0" 0 DOOR AND FRA -SCHEDULE DOOR NOTES: 1. SEE SPECS FOR DOOR AND FRAME FINISH SPECIFIC 2. CAULK JOINT BETWEEN FRAME AND OUTSIDE FACE OF DRYWALL. 3. REFER TO A200 SERIES FLOOR PLAN FOR DOOR AND GLAZED FRAME OPENING LOCATIONS. 1 11 DOOR MARKER 2. KEY ALL LOCKS TO MATCH ENTRANCE DOOR LOCKS. DOOR 3. IF NO EXISTING PANIC HARDWARE ON EXISTING EXTERIOR DOORS, USE E-1 FOR HARDWARE FRAME I REMARKS L-1 ENTRY FUNCTION L-4 PASSAGE FUNCTION SIZE L-3 STORAGE FUNCTION L-6 OFFICE FUNCTION _ L-7 THRU BOLT TOP AND BOTTOM -LEAF 1, STORAGE FUNCTION LEAF 2 STOPS ABBREVIATIONS S-1 WALL STOP S-2 HINGE STOP PUSH/PULL TYPE MODEL # FINISH BRAND P-1 1/LEAF PULL 980P US32D HAGER 1/LEAF PUSH 1105 US32D HAGER ST = STEEL P-2 1/LEAF PULL MANUFACTURER'S STANDARD DOOR ELEVATIONS CLOSER TYPE MODEL # FINISH BRAND D-1 1/LEAF SURFACE CLOSER 7700 26 NORTON PANIC TYPE MODEL # FINISH BRAND E-1 SURF. MNT RODDED PANIC MANUF. STNDRD US32D KAWNEER E-2 PANIC -RIM DEVICE 98/98 RIM US32D VON DUPRIN HM =HOLLOW METAL z WD = WOOD z SS = STAINLESS STEEL O Q z 0 ¢ T Z 0 INS =INSULATED GLASS = TEMPERED GLASS � = z w Cf)¢3 x UO n- EE s (n F-- AL = ALUMINUM PF = PREFINISHED p w ¢ Z J CD ¢ zJ PT = PAINTED C:)s � EL.. w __i V)m = w FX = FAUX WOOD, COMPOSITE 102 3'-0" 6-8" WD PF D1 L-6 S-1 WD PT - 103 3'-0" 6-8 WD PF D1 L-6 S-1 WD PT - 104 3'-0" 6-8" WD PF D1 L-6 S-1 WD PT - _ 105 3'-0" 6-8" WD_ PF D1 L-6 S-1 WD PT -� 106 3'-0" 6-8" WD PF D1 L-6 S-1 WD PT - 107 3'-O" 6-8" WD PF D1 L-6 S-1 WD PT - 108 3'-0" PR 6-8" WD PF D1 L-6 S-1 WD PT - 109 3'-0" 6-8" WD PF D1 L-6 7-1 FID PT - EXIST 3'-O" 6-8" VAR. PF VAR. L-1 S-2 WD I PT - EXISTING DOOR -ALL EGRESS HARDWARE TO REMAIN LOCKSETS LOCKSET NOTES: 1. ALL INTERIOR DOOR HARDWARE TO BE SCHLAGE TYPE "AL -SERIES," REF. BUYER SPECIFICATIONS FOR FINISHES, 2. KEY ALL LOCKS TO MATCH ENTRANCE DOOR LOCKS. 3. IF NO EXISTING PANIC HARDWARE ON EXISTING EXTERIOR DOORS, USE E-1 FOR DOUBLE LEAF OPENINGS AND E-2 FOR SINGLE. L-1 ENTRY FUNCTION L-4 PASSAGE FUNCTION L-2 PRIVACY FUNCTION L-5 REMOTE RELEASE FUNCTION L-3 STORAGE FUNCTION L-6 OFFICE FUNCTION L-7 THRU BOLT TOP AND BOTTOM -LEAF 1, STORAGE FUNCTION LEAF 2 STOPS *MATCH LOCKSET FINISH S-1 WALL STOP S-2 HINGE STOP PUSH/PULL TYPE MODEL # FINISH BRAND P-1 1/LEAF PULL 980P US32D HAGER 1/LEAF PUSH 1105 US32D HAGER D1 P-2 1/LEAF PULL MANUFACTURER'S STANDARD DOOR ELEVATIONS CLOSER TYPE MODEL # FINISH BRAND D-1 1/LEAF SURFACE CLOSER 7700 26 NORTON PANIC TYPE MODEL # FINISH BRAND E-1 SURF. MNT RODDED PANIC MANUF. STNDRD US32D KAWNEER E-2 PANIC -RIM DEVICE 98/98 RIM US32D VON DUPRIN e GENERAL ... NOTES.. A. ALL DIMENSIONS ARE FROM FACE OF STUD, OR FACE OF MASONRY, OR FACE OF CONCRETE WALL, ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT/DESIGNER. DO NOT SCALE DRAWINGS. B. PROVIDE WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. C. COORDINATE WORK OF THIS TRADE WITH OTHER TRADES. D. PROVIDE MISCELLANEOUS SUPPORT FOR ALL CEILING SUSPENDED ITEMS, E. APPLY SEALANT AT ALL JUNCTURES BETWEEN DIFFERENT MATERIALS (I.E. WINDOWS AND CAST STONE). F. APPLY SEALANT AT ALL PLUMBING FIXTURES AT JUNCTURE WITH WALL. G. APPLY SEALANT AT ALL COUNTERTOPS AND BACK SPLASHES AT JUNCTURE WITH WALL. H, INTERIOR STUD WALLS TO BE 24" O.C., U.N.O. ALL STUD BEARING WALLS TO BE 16' O.C. L 4' HIGH WALLS TO BE TRIMMED AND lx CAP INSTALLED J. REUSE EXISTING COUNTERTOPS AND CABINETS WHERE POSSIBLE PSL 9E S: 0 NEW WATER FOUNTAIN r NOV u 8 201 LEGEND: 113 DOOR LABEL DINING ROOM ROOM NAME NEW INTERIOR NON -LOAD BEARING WALL PLAN NOTE CALL OUTS 1711111 Rm-, J NOTES:1 - ALL WALLS TO EXTEND TO THE BOTTOM OF THE CEILING GRID, APPROX. 9'-2" A.F.F. 2 - PROVIDE CONCRETE WALLBOARD ON ALL WET AREA WALLS W1 3 5/8" 25 GAUGE METAL TRACK R "- WITH 3 1/2" METAL STUDS @ 24" O.C. N AND 1/2" GYPSUM WALL BOARD EACH SIDE EX EXISTING WALL TO REMAIN Project No. '17-049 Sheet No. .................................I .......... ..... ........ ............. .......................... .._...___. S {£ % {% I % S 5 3 ..�.. .... .............. .................. ...............r v.............. ........................ .,.r.r .. .. ................................. .. ..................r........ j1 ........................,....,..,..........r....................n,...v I .......v...v....v:...:.....:.....,............... i �l t, .....n., ....:...:..n........:.. .. ...................... ..,............r....r ....:::..:....................,...........,,.r.,.., .... .......... ! ! !.: .:...: v: % % ,,..n........+..... .... ... ....,..,..,r, r ............. ........ .... ...,,............ ................ .........,.,,..., ,.,..,..,:,...... ................ ... ................. ................. ................. ................. .............,... Y i 1 } s NORTH ..n... 5 ...... ....... ........................... .. ............ ...............r v.............. ........................ .,.r.r .. .. ................................. .. ..................r........ j1 ........................,....,..,..........r....................n,...v I .......v...v....v:...:.....:.....,............... v......r.: t, .....n., ....:...:..n........:.. .. ...................... ..,............r....r ....:::..:....................,...........,,.r.,.., .... .......... ! ! !.: .:...: v: ....................... ,,..n........+..... .... ... ....,..,..,r, r ............. ........ .... ...,,............ ................ .........,.,,..., ,.,..,..,:,...... ................ ... ................. ................. ................. ................. .............,... �: s }: i < < i % c �. 3 q5 £ _ SCALE: 1/411 = 1'-0" E C E ILL N U N000"' T E 1. LIGHTS & DIFFUSERS ON DRAWINGS ARE FOR LOCATION ONLY. COORDINATE WITH MECHANICAL & ELECTRICAL DRAWINGS FOR EXACT SPECIFICATIONS AND VERIFICATION OF QUANTITY. 2. CENTER ACCOUSTICAL CEILING PANELS IN EACH DIRECTION WITHIN i HE MAIN PORTION OF ANY ROOM OR SPACE, UNLESS NOTED OTHERWISE. 3. CEILING GRID SHALL BE SUPPORTED FROM STRUCTURAL MEMBERS ONLY, GRID SHALL NOT BE SUPPORTED FROM OTHER TRADES WORK. 4. HANGER WIRES FOR GRID SHALL BE INSTALLED AT NOT MORE THAN 48"O.C. AND AT EACH CORNER OF LAY -1N LIGHT FIXTURES, SEE ELECTRICAL PLANS FOR FIXTURE LOCATIONS. 5. CONTRACTOR IS TO MOVE THE LOW VOLTAGE RACK SO THE BOTTOM IS A MINIMUM 6'-8" A.F.F. 6. CONTRACTOR IS TO MOVE AND ADJUST HVAC DIFFUSERS ONE SQUARE HERE OR THERE TO AVOID CONFLICT WITH NEW WALLS. ALSO RE -BALANCE PER NEW ROOM SIZE. 7. DESIGN INTENT IS TO KEEP FIRE SPRINKLER SYSTEM AND HEADS IN TACT. ANY ADJUSTMENT OF LOCATION MUST BE BY APPROVED FIRE SPRINKLER DESIGN/BUILDER, CEILING 20 SUSPENDED ACCOUSTICAL PANEL CEILING EXISTING TO REMAIN MECHANICAL SUPPLY DIFFUSER, SEE MECHANICAL EXISTING TO REMAIN, RELOCATE AS NEEDED. MECHANICAL RETURN AIR GRILLE, SEE MECHANICAL EXISTING TO REMAIN, RELOCATE AS NEEDED, EXHAUST FAN, SEE MECHANICAL EXISTING TO REMAIN, RELOCATE AS NEEDED. CEILING FAN EXISTING TO REMAIN, RELOCATE AS NEEDED. 2X4 LIGHT FIXTURE EXISTING TO REMAIN, RELOCATE AS NEEDED. ® LIGHT FIXTURE, RECESSED ADJUSTABLE GIMALIGHT EXISTING TO REMAIN, RELOCATE AS NEEDED. t WALL MOUNTED FIXTURE EXISTING TO REMAIN, RELOCATE AS NEEDED. EMERGENCY LIGHT FIXTURE ® EXIT SIGNAGE & LIGHT .. - FINISH SCHEDULE a BOTTOM CHORD OF FLOORS PRE -FAB TRUSS REMARKS FLOOR �^ ATTACH STUDS TO STRUCTURE NORTH EAST SOUTH WEST ABOVE @ 48" O.C. NAME -- C) CEILING - HEIGHT VARIES - SEE SHEET A202 BLOCKING AT 101 CENTERLINE OF WALL WT B #" PLYWD. AT ALL GWB-PT GWB-PT KITCHEN WALLS 102 BLOCKING WHERE CPT B REQUIRED GWB-PT GWB-PT P.T. PLATE IN CONTACT 103 OFFICE B CPT w/ SLAB � I U q GWB-PT GWB-PT 104 OFFICE C CPT 0 GWB-PT SCALE: 3/4" = 1'-0" T IV -V 11's r%wl oa ELEVATIvri BRE AK,Rfw"' 0" M COUNTER SCALE: 1/2)) = 1'-0" CABINET WITH ADJUSTABLE SHEL( 4" BACKSPW SIS P.L. #1 OVER 3/4" PLYWOC (COUNTER TO (2)- WHITE MELAM (ADJUSTABLE SHELVI P.L. (FACE OF CAE 6" RESILIENT Bf CLG. HT. ' "ECTIV00"No Oa 0 'hREAKRvj""0*mffl'm Ck"J"'UN"'TER :. SCALE: 3/4" = V-0" CLO. HT. 1'-0" 1'-11y" 1'-11y" 1'-11y" 1'-11y" V V -1 1Y° v 1'-11)/2" 1'-11}x" F____7 7 - If - �ll�-----I�------1 I II II II II' II II II % II \ iI -% II \ II % SII / J--- JJ-__�L� ___JJ-_- �1L� ^-_Jll 4" BACKSPLASH P.L N1 (COUNTER TOP) RTRIDGERATQR DY OWNER)) I <<< II Iit III II II I I iI I I I iI I II II II II II II II F.F. +0'-U" ELEVATION 3 BREAKROOM COUNTER A401 SCALE: 1/2" = 1'-0" ROOM FINISH SCHEDULE a ROOM FLOORS WALLS REMARKS FLOOR ASE NORTH EAST SOUTH WEST NAME C) 101 RECEPTION AREA WT B GWB-PT GWB-PT GWB-PT GWB-PT 102 OFFICE A CPT B GWB-PT GWB-PT GWB-PT GWB-PT 103 OFFICE B CPT B GWB-PT GWB-PT GWB-PT GWB-PT 104 OFFICE C CPT B GWB-PT GWB-PT GWB-PT GWB-PT 105 OFFICE D CPT B GWB-PT GWB-PT GWB-PT GWB-PT 106 OFFICE E CPT B GWB-PT GWB-PT GWB-PT GWB-PT 107 OFFICE F CPT B GWB-PT GWB-PT GWB-PT GWB-PT 108 CONFERENCE ROOM CPT B GWB-PT GWB-PT GWB-PT GWB-PT 109 BREAK ROOM VCT B GWB-PT GWB-PT GWB-PT GWB-PT - 110 HALL CPT B GWB-PT GWB-PT GWB-PT GWB-PT 111 FILE ROOM VCT B GWB-PT GWB-PT GWB-PT GWB-PT 112 IT ROOM VCT B GWB-PT GWB-PT GWB-PT GWB-PT 113 RESTROOM 1 VCT B GWB-PT GWB-PT GWB-PT GWB-PT 114 RESTROOM 2 VCT B GWB--PT GWB-PT GWB-PT GWB-PT 1. ALL WALL FINISHES TO BE OF TYPE 'B' CLASSIFICATION OR BETTER. 2. ALL FLOOR FINISHES TO BE OF TYPE '2' CLASSIFICATION OR BETTER. *MOISTURE RESISTANT GWB-EPDXY PAINT ON WALLS IN ALL RESTROOMS FROM FINISH FLOOR TO +4'-0". A.F.F. MINIMUM. LEGEND: FLOORS BASE ONC: SEALED CONCRETE B: BASE TO MATCH FLOORING WALLS VCT: VINYL COMPOSITE TILE COLOR: TBD PT: PAINT U.N.O. - COLOR TBD FRP: FIBERGLASS REINFORCED PLASTIC PANELS CPT: CARPET COLOR: TBD SS: STAINLESS STEEL WT: WOOD TILE CEILING COLOR: TBD ACST 1: ARMSTRONG DUNE WHITE W/9/16" GRID; TEGULAR EDGE FINISH SPEC LEGEND: �x INDICATES RASE FINISH O INDICATES FLOOR FINISH O INDICATES WALL FINISH 7'-2,Y" 1ENLARGED RESTROOM PLAN A601 SCALE: 1/2 = 1'-0" ACCESSORY SCHEDULE # ITEM MANUFACT.* CATALOG # GRAB BAR - 30" BOBRICK 819388 [ GRAB BAR - 42" BOBRICK B-6806-42 �3 NOT USED -- -- Q SURFACE -MOUNTED TOILET PAPER HOLDER BOBRICK B-4288 NOT USED -- -- ® NOT USED -- -- 0 I POLISHED PLATE GLASS MIRROR - 32"40" BOBRICK B-4354 ® CLOTHING HOOK BOBRICK B-6707 9 PAPER TOWEL DISP, AND WASTE RECEP. BOBRICK B-4369 10 SOAP DISPENSER BOBRICK B-4112 "UK Ah'I'KUVLU LQUAL 3'-0" 0 I MIRROR ca R R Q I I I MIRROR A.D.A MIRROR PAPER TOWEL DISP. A.D.A SOAP TOILET TISSUE & WASTE RECEPTACLE DISPENSER DISPENSER SURFACE MOUNTED DOUBLE ROLL TISSUE DISPENSER. ATTACH TO WALL OR TOILET PARTITION 36" LONG V-6" GRAB BAR 42" LONG GRAB BAR 1'-0" 6" - L 7 0 -- M "f01LEi-Y � i TISSUE DISP. 8 MIN, Z 1 V7 z � � 6M DRINKING FOUNTAIN 3ABY CHANGING STATION r r r GRAB BARS LAVATORY FINISH CEILING -F9,_2» r6 FINISH FLOOR PAINT (PT -2) PAINT (PT -2) PAINT PAINT (PT -2) NOTE: FLUSH CONTROL SHALL BE ON THE WIDE SIDE OF THE WATER CLOSET CLEAR FLOOR SPACE. t DIVISION 10: SPECIALTIES SECTION 1OA: TOILET ACCESSORIES GENERAL PROVISIONS 1. SCOPE: INSTALL TOILET PARIMONS WHERE APPLICABLE, TOILET ACCESSORIES, AND RELATED HARDWARE AS SHOWN ON PLANS OR INSTALLATION DRAWINGS, 2. SUBMISSIONS: PROVIDE INSTALLA110N DRAWINGS TO OWNER'S REPRESENTATIVE SHOWING THE SIZE AND LOCATION OF EACH COMPONENT AND ROUGH OPENING SIZES AND MOUNTING HEIGHTS. LABEL ALL COMPONENTS TO CORRESPOND TO INSTRUCTIONS FOR EASE OF INSTALLATION. MATERIALS 1. DOORS FOR TOILET COMPARTMENTS WHERE APPLICABLE WITH STUD WALL PARTITIONS SHALL BE 3/4" X 58" HIGH TOILET STALL DOORS WITH STANDARD HINGES 1502 CATCH SLIDE SURFACE STRIKE 15140 FOR OUTSWINGING DOORS, AND 15260 SURFACE STRIKE FOR IN -SWINGING DOORS, COAT ,HOOK WITH RUBBER BUMPER AT 48" O.C. 2. STALL DOOR HINGE JAMB: 1-1/4" X 1-1/4" X 8'-0" MILL FINISH ALUMINUM TUBE HINGE JAMB POST FOR TOILET STALL DOORS. PRE -DRILL FOR 112 SCREWS 0 8" O.C. 3. PANELIZED TOILET COMPARTMENTS & DOORS (WHEN SHOWN) SHALL BE GLOBAL. PARTITIONS PLASTIC LAMINATE FLOOR MOUNTED, OVERHEAD -BRACED TOILET PARTITIONS AND/OR FLOOR MOUNTED, CEILING BRACED URINAL SCREEN WITH STAINLESS STEEL PILASTER SHOE COVERS, FINISH: HPL - WINDSWEPT BRONZE # 9292. DOORS TO HAVE COAT HOOK WITH RUBBER BUMPER. 4. ACCESSORIES REFER TO DRAWINGS. PERFORMANCE 1. INSTALL ACCESSORIES, AND HARDWARE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION DRAWINGS. 1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN SHALL BE DISPLAYED AT ALL ACCESSIBLE RESTROOM FACILITIES AND AT ACCESSIBLE BUILDING ENTRANCES UNLESS ALL ENTRANCES ARE ACCESSIBLE. INACCESSIBLE ENTRANCES SHALL HAVE DIRECTIONAL SIGNS INDICATING THE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE. 2. RECEPTACLES ON WALLS SHALL BE MOUNTED NO LESS THAN 15" ABOVE THE FLOOR. EXCEPTION: HEIGHT UMTTAIIONS DO NOT APPLY WHERE THE USE OF SPECIAL EQUIPMENT DICTATES OTHERWISE OR WHERE ELECTRICAL RECEPTACLES ARE NOT NORMALLY INTENDED FOR USE BY BUILDING OCCUPANTS. 3. WHERE EMERGENCY WARNING SYSTEMS ARE PROVIDED, THEY SHALL INCLUDE BOTH AUDIBLE AND VISUAL ALARMS. THE VISUAL ALARMS SHALL BE LOCATED THROUGHOUT, INCLUDING RESTROOMS, AND PLACED 80" ABOVE THE FLOOR OR 6" BELOW CEILING, WHICHEVER IS LOWER. 4. DOORS TO ALL ACCESSIBLE SPACES SHALL HAVE ACCESSIBLE HARDWARE (i.e. LEVER -OPERATED, PUSH -TYPE, U -SHAPED) MOUNTED NO HIGHER THAN 48' ABOVE THE FLOOR. 5. FLOOR SURFACES SHALL BE STABLE, FIRM, AND SUP -RESISTANT, CHANGES IN LEVEL BETWEEN 0.25" AND 0.5" SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2". CHANGES IN LEVEL GREATER THAN 0.5' REQUIRE RAMPS. CARPET PILE THICKNESS SHALL BE 0.5" MAX. GRATIN,'F IN FLOOR SHALL. HAVE SPACES NO GREATER THAN 0.5" WIDE IN ONE DIRECTION: DOORWAY THRESH( )S SHALL NOT EXCEED 0.5" IN HEIGHT. 6. GRAB BARS REQUIRED FOR ACCESSIBILITY SHALL BE 1.25"-1.50' IN DIAMETER WITH 1.5" CLEAR SPACE BETWEEN THE BAR AND THE WALL. 7. ACCESSIBLE WATER CLOSETS SHALL BE 17"-19" FROM FLOOR TO THE 'fop OF THE SEAT. GRAB BARS SHALL BE 36" LONG MINIMUM WHEN LOCATED BEHIND WATER CLOSET AND 42" MINIMUM WHEN LOCATED ALONG SIDE OF WATER CLOSET, AND SHALL BE MOUNTED 33"-36" ABOVE THE FLOOR, 8. ACCESSIBLE URINALS SHALL BE STALL -TYPE OR WALL HUNG WITH ELONGATED RIMS AT A MAXIMUM OF 17" ABOVE THE FLOOR. 9. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34" ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 29" ABOVE THE FLOOR TO THE BOTTOM OF THE APRON. 10. ACCESSIBLE SINKS SHALL. BE MOUNTED WITH THE RIM NO HIGHER THAN 34" ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 27" HIGH, 30" WIDE, AND 19" DEEP UNDERNEAIH SINK. THE SINK DEPTH SHALL BE 6.5" MAXIMUM. 11. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT, THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER 12. ACCESSIBLE LAVATORIES AND SINKS, ACCESSIBLE LAVATORIES AND SINKS SHALL HAVE ACCESSIBLE FAUCETS (i.e. LEVER -OPERATED, PUSH -TYPE, ELECTRONICALLY CONTROLLED.) 13. WHERE MIRRORS ARE PROVIDED IN RESTROOM, AT LEAST ONE SHALL BE PROVIDED WITH THE 80TfOM EDGE OF THE REFLECTIVE SURFACE NO HIGHER THAN 40" ABOVE THE FLOOR. 14. GRAB BARS REQUIRED FOR ACCESSIBILITY SHALL BE 1.25"-1.50" IN DIAMETER WITH 1.5" CLEAR SPACE BETWEEN THE BAR AND THE WALL. 15. ACCESSIBLE WATER CLOSETS SHALL BE 17"-19" FROM FLOOR TO THE TOP OF THE SEAT. GRAB BARS SHALL BE 36" LONG MINIMUM WHEN LOCATED BEHIND WATER CLOSET AND 42" MINIMUM WHEN LOCATED ALONG SIDE OF WATER CLOSET, AND SHALL BE MOUNTED 33"-36" ABOVE THE FLOOR. 16. ACCESSIBLE URINALS SHALL BE STALL -TYPE OR WALL HUNG WITH ELONGATED RIMS AT A MAXIMUM OF 17" ABOVE THE FLOOR. 17. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34" ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 29" ABOVE THE FLOOR TO THE BOTTOM OF THE APRON, 18. ACCESSIBLE SINKS SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34" ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 27" HIGH, 30" WIDE, AND 19" DEEP UNDERNEATH SINK. THE SINK DEPTH SHALL BE 6.5" MAXIMUM. 19. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER 20. ACCESSIBLE LAVATORIES AND SINKS. ACCESSIBLE LAVATORIES AND SINKS. SHALL HAVE ACCESSIBLE FAUCETS (i.e. LEVER -OPERATED, PUSH -TYPE, ELECTRONICALLY CONTROLLED.) 21. WHERE MIRRORS ARE PROVIDED IN RESTROOM, AT LEAST ONE SHALL BE PROVIDED WITH THE BOTTOM EDGE OF THE REFLECTIVE SURFACE NO HIGHER THAN 40" ABOVE THE FLOOR. Project No. 17-049 Sheet No. ELECTRICAL 5YM bO L5 CMERGF_NCY BATTERY EXIT LIGHTING FIXTURE UNIT CONNECT AHEAD OF ROOM LIGHTING SWITCH. C=I EMERGENCY BATTERY UNIT LIGHTING FIXTURE - WALL MOUNTED CONNECT AHEAD OF ROOM LIGHTING SWITCH, SINGLE POLE -TOGGLE SWITCH - MOUNTED 48" AFF TO CENTERLINE UNLE55 OTHERWISE NOTED (3) 3 WAY (4) 4 WAY (T) WALLBOX WIND-UP TIMER 5�NITCH, GO -MINUTE. EQUAL TO LEVITON OR INTkRMATIC. (05) WALLBOX OCCUPANCY SENSOR SWITCH. DUAL INfARED/ULTRASONIC EQUAL TO LEVITON, INTEKMATIC, WATT STOPPER. OS CEILING MOUNTED OCCUPANCY SENSOR, SIMILAR "TO DESCRIBED ABOVE. "LV"= PROVIDE LOW -VOLTAGE INTERCONNECTION TO MULTIPLE DEVICES AND 20 -AMP POWER, RELAY FOR CONTROLLED LIGHTING LOAD. [� DECOKA SLIDE -TYPE DIMMER, 1200 -WATT MIN, UNO, 48" AFF TO CENTERLINE UNLE55 OTHERWISE NOTED DUPLEX RECEPTACLE - MOUNTED I P" AFF TO CENTEF11NE UNLESS NOTED OTHERWISE (GFI) GROUND FAULT INTERRUPTING (WP) WEATHERPROOF WfIH GFI DUPLEX RECEPTACLE ABOVE COUNTER. SEE CASEWORK PLANS. DOUBLE DUPLEX RECEPTACLE - MOUNTED 15" AFF TO CENTERLINE UNLE55 NO -TED OTHERWISE ® .SPECIAL PURPOSE RECEPTACLE. SEE PLAN NOTES. D COMMUNICATION5 OUTLET - MOUNTED 18" AFF TO C.L. U.N.O. TYPICAL RUN .3/4" CONDUIT TO ACCE55ABLE CEILING SPACE. PROVIDE 2 GANG BOX WITH ONE GANG RING (TYPICAL). ® COMMUNICATIONS OUTLET - ABOVE COUNTER OR HEIGHT AS NOTED. 50LID LINE INDICATES EQUIPMENT" ON COMMON CIRCUIT AND/OR CONTROLLED BY COMMON SWITCH. PROVIDE NECESSARY SWITCH LEGS IN CONDUIT TO ACHIEVE SWITCHING INDICATED ON PLAN5. DOTTED LINE INDICATE5 EQUIPMENT ON A COMMON CIRCUIT BUT NOT CONTROLLED ON SAME SA/ITCH DEVICE. VSS TRANSIENT VOLTAGE SURGE PROTECTOR. SEE SPECS. a FIRE ALARM PULL 5TATION.46" AFF --b---? FIRE ALARM SPRINKLER FLOW SWITCH FIRE ALARM SPRINKLER TAMPER SWITCH FIRE ALARM DUCT SMOKE DETECTOR Q SMOKE DETECTOR ® HEAT DETECTOR DENOTES RECE55ED WALL MOUNTED AUDIO/STROBE COMBINATION ALARM TIED INTO EXI5TING FIRE ALARM SYSTEM MOUNTED AT ZO" A.F.F. DENOTES RECESSED WALL MOUNTED 5'FROBE ALARM TIED INTO EXISTING FIRE ALARM SYSTEM MOUNTED AT 60" A.F.F. GENERAL NOTES: I ALL WORK SHALL COMPLY WITH CODES AND 5TANDARD5 LISTED IN T' -IE 5FECIFICATION5. 2. -THE DRAWINGS ARE DIAGRAMATIC AND THE OM155ION OF AN ITEM NECESSARY FOR THE PROPER FUNCTIONING OF 'THE SYSTEM DOES NOT RELIEVE THE CONTRACTOR FROM FURNISHING AND INSTALLING THAT ITEM. 3. NOTIFY ARCHITECT/ ENGINEER OF ANY CONFLICTS PRIOR TO PURCHASING E=QUIPMENT AND PRIOR TO CUTTING OPENING, 4. PRIOR TO BID, COORDINATE ALL ELECTRICAL. WORK WITH MECHANICAL WORK AND OTHER TRADES. SEE 5PECIFICATION5 FOR KEC.ZUIRCMENTS. 5. CONTRACTOR SHALL NOT CONCEAL ANY WORK UNTIL IN5PECTED BY ELECTRICAL INSPECTOR AND/OR ARCHITECT/ENGINEER. CONTRACTOR SHALL NOTIFY A/E OF A SCHEDULED I1\15PECTION TIME WITHIN 72 HOURS. CONTRACTORS SHALL NOT CONCEAL WORK UNTIL APPROVED. F,, ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ARCHITECT AND GENERAL CONTRACTOR ON REQUIREMENTS FOR STRUCTURAL 5UPP0KT AND fKAMING FOR ALL ELECTRICAL EQUIPMENT AND SYSTEMS. GENERAL CONTRACTOR SHALL BE RC5PON5IbLE FOR PROVIDING AND VERIFYING STRUCTURAL SUPPORT AND FRAMING. 7. THE SIZE, LOCATION, WDGHT, AND NEC ARTICLE 1 10/364 REQUIRED 5CF,'.VICE CLEARANCES OF EQUIPMENT INSTALLED UNDER DIVI5IQN I G ELECTRICAL SHALL BE COORDINATED WITH ALL OTHER TRADES. S. WHERE CROWDED LOCA -.`IONS EXIST OR WHE=RE THERE 15 A F05SIBILI-FY OF CONFLICT BETWEEN TRADE5, CONTRACTOR SHALL MA.<E COMPOSITE DRAWINGS SHOWING 'THE EXACT LOCATION OF DUCTS, CONDUIT AND EQUIPMENT. DRAWING5 :SHALL BE BASED ON FIELD MEA5UREMENT5 AND, AFTER CONSULTATION AND AGREEMENT BETWEEN THE TRADES, `HALL BE APPROVED BY THE ARCHITECT BEFORE INSTALLATION OF THE WORK, 9. ELECTRICAL CONTRACTOR 15 TO PROVIDE PULL STRINGS IN ALL EMPTY CONDUIT AND RACEWAYS WITH LABELING TAGS AT EACr END. 10. ALL RACEWAY TERMINATION'S SHALL HAVE 151 J5HING5 AND BE GROUNDED WHERE RACEWAY 15 METAL. 1 1. ALL BARE METAL SURFACE5 SHALL BE PRIMED AND PAINTED TO PREVENT ANY RUST, INCLUDING BUT NOT LIMITED TO ANGLE FRAMING, EQUIPMENT SUPPORTS, MOUNTING HARDWARE, .FTC. 12, DO NOT SCALE FROM TNE5E DRAWINGS. REFER.:.TO ARCHITECTURAL PLANS FOR DIMENSIONS. 13, ALL RACEWAYS SHALL HAVE A GREEN GROUNDING CONDUCTOR. 14. ALL NEW BREAKERS IN EX15-FING PANC1_5 SHALL HAVE AN AIC RATING EQUAL TO OR GREATER THAN THE HIGHEST RATED BREAKCF; IN THAT PANEL. 15. CONTRACTOR SHALT ALL NF_W AND EXISTING ELECTRICAL. PENETRAIION5 IN FIRE RATED PARTITIONS (WALLS, FLOORS OR CEILINGS) WITH AN APPROVED FIRCSTOP 5Y.STrM RATED FOK THE APPLICATION. FIRE5TOP 5Y5TEM SHALL. BE UL LISTED AND INSTALLED IN 5TRIC;T COMPLIANCE WITH THE MANUFACTURCF,'5 INSTF�UCTIONS. I G. EC SHALL FURNISH AND INSTALL EXPAN51ON JOINTS AT ALL LOCATIONS WHERE BUILDING EXPANSION JOINTS ARE USED. 17. COORDINATE ALL. MECHANICAL LOADS, VOLTAGES AND LOCATIONS WITH MECHANICAL CONTRACTOR AND MAKE NECE55ARY ADJUSTMENTS WITHOUT EXTRA CHAKGE5. 1 (5. EC MAY INSTALL MULTIPLE CIRCUITS INDICATED ON PANEL SCHEDULE IN A SINGLE CONDUIT. EC SHALL BE RESPONSIBLE FOR VERIFYING CONDUIT FILL AND CONDUCTOR DERATING. 19. ALL POWER AND WIRING SHALL BE CONCEALED WHERE PRACTICAL, SURFACE MOUNTED RACEWAY SHALL BE WIREMOLD (OR EQUIVALENT) METALLIC SURFACE RACEWAY. CONTRACTOR SHALL PROVIDE AND INSTALL. ALL RACEWAY, BOXES, AND FITTINGS REQUIRED FOR A COMPLETE INSTALLATION. CABLING IN NON-PUBLIC AREAS MAY BE IN EMT. 20, SURGE PROTECTION SHALL BE PROVIDED ON ALL CARL E5 ENTERING/ EXITING BUILDINGS THAT CONNECT TO ELECTRICAL EQUIPMENT. 21. ALL SITE EXCAVATION OR TRENCHING SHALL BC DONE BY HAND, ALL CONDUITS SHALL HAVE A MINIMUM BURIAL DEPTH OF 2.4 22. NO 5FLICE5 SHALL BE FERMI -FED IN UNDERGROUND/ FLUSH IN -GRADE PULL BOXE5 WITHOUT PRIOR WRITTEN APPROVAL BY OWNER. 23. ANY REDUCTION IN CABLE 51ZE TO FIT ON LUGS 15 THE RESPONSIBILITY OF THE CONTRACTOR IF CALLED FOR ON THE DRAWINGS OR NOT. 2.4. ALL WIRE AND CONDUIT SIZES SHOWN ARE BASED ON THE LENGTH OF THE A55UMED ROUTING OF THE WIRE AND CONDUIT AND VOLTAGE DROP COMPLIANCE. CONTRACTOR SHALL VERIFY THE WIRE AND CONDUIT SIZE BASED ON THE ACTUAL LENGTH OF THE ROUTE AND ADJUST AS REQUIRED MEETING AL.L. REQUIRED VOLTAGE DROPS. 25, THE CONTRACTOR MUST CONTACT THE POWER COMPANY IMMEDIATELY AFTER FINAL DOCUMEN"175 HAVE BEEN SUBMITTED TO OPEN UP A WORK ORDER. CONTRACTOR SHALL PROVIDE THE POWER COMPANY ENGINEER A SET OF ELECKICAL DRAWINGS AND A COMPLETED LOAD .CALCULATION SHEET. INFORMATION SHOWN ON DRAWINGS REGARDING THE POWER COMPANY TRANSFORMER, AIC RAFING5, CT CABINETS SERVICE DI5CONNCCT5 ETC. ARE SUBJECT TO CHANGE BASED ON THE FINAL POWER COMPANY SERVICE DESIGN, CONTRACTOR SHALL ALLOW FOR THESE POSSIBLE CHANGES AND MAKE MODIFICATIONS LIGHTING FIXTURE 5CHEDULE 'TYPE LAMP5 DESCRIPTION MANUFACTURER / CATALOG NUMBER NO TYPE E SECTION I GG 10 - SURGE PROTECTION LCD EMERGENCY WALL PACK GENERIC 1. POWER PANEL SURGE PROTECTORS, WHERE SHOWN ON THE PLANS, SHALL X 2. OUTDOOR DEVICE 5OXE5 SHALL BE CAST FS TYPE WITH GASKETED COVERS, LED EXIT SIGN, WHITE WITH RED WILLIAMS OR EQUAL EXIT-R-EM-WHT ELECTRICAL 5PECIfICATION5 SECTION I GO 10 - ELECTRICAL GENERAL PROVISIONS SECTION 16050 - ELECTRICAL BASIC MATERIALS AND METHODS SECTION I G 195 - ELECTRICAL IDENTIFICATION SECTION I GG 10 - SURGE PROTECTION ' 1, ALL WORK AND EQUIPMENT SHALL BE IN COMPLIANCE WITH THE 1. COLOR FOR PLATES AND DEVICES SHALT_ BE AS DIRECTED BY THE ARCHTECT . 1. PROVIDE EACH BRANCH CIRCUIT PANEL. WITH A DIRECTORY INDICATING 1. POWER PANEL SURGE PROTECTORS, WHERE SHOWN ON THE PLANS, SHALL FOLLOWING CODES AND 5TANDARD5: 2. OUTDOOR DEVICE 5OXE5 SHALL BE CAST FS TYPE WITH GASKETED COVERS, LOADS SERVED. THE PANEL SCHEDULES SHOWN ON THE PLANS DO NOT BE MOV SINGLE -STAGE TYPE 75,000 KA PER PHASE WITH FU51NG AND INDICATOR A. FLORIDA BUILDING CODE 2014 5TH EDITION UNLE55 INDICATED OTHERWISE. PVC 15 APPROVED WITHIN CONCRETE WALLS, CONTAIN ADEQUATE INFORMATION TO BE COPIED AND USED AS PANEL LAMP5 PER CURRENT U.L. 1449 STANDARD. B. NATIONAL ELECTRICAL CODE, 201 I 3. OUTDOOR BELOW GRADE PULL BOXE5 SHALL BE NON-METALLIC OPEN- DIRECTORIES. LABEL EACH CIRCUIT WITH ACTUAL ROOM NUMBERS OR 2. PROVIDE L -L, L -N, N -G PROTECTION MODES. C. NATIONAL FIRE ALARM CODE, CURRE=NT EDITION. BOTTOM WITH NON-METALLIC NON -TRAFFIC RATED COVER, BROOKS OR ROOM NAMES SERVED, SUCH A5 "RE CPT 109, 110, 1 1 1 ". 3. CONNECT VIA SHORT 5TRAIGI IT # 10 WIRES -TO 30 -AMP CO. 2. ALL MATERIALS SHALL BE NEW AND FREE FROM DEFECT, EXCEPT WHERE EQUAL. DO NOT MAKE 5PLICE5 IN BELOW GRADE PULL BOXES. 2. ALL PANELS AND DISCONNECTS SHALL BE LABELED REGARDING LOADS SPECIFICALLY NOTED ON THE PLAN5 TO BE RECONNECTED OR REUSED. SERVED AND WHERE SERVED FROM. SECTION 16500 - LIGHTING 3. ALL 5Y5TEM5 SHALL DETESTED FOR PERFORMANCE VERIFICATION IN THE 4. PVC CONDUIT 511ALL BE USED UNDERGROUND AND OUTDOORS ONLY. 3. USE ENGRAVED PLAQUES FOR LABELING LARGE EQUIPMENT. I SIGNS SHALL BE PROVIDED WITH ARROWS AND FACES TO MATCH PRESENCE OF THE OWNER. PVC ABOVE GROUND INDOORS IS PERMIT"TED TO THE FIRST BOX OR PANEL 4. LABEL EACH POWER .JUNCTION BOX WITH AN INDELIBLE MARKER .EXIT FIELD CONDITION5 AND 50 AS TO BE CLEARLY VISIBLE FROM ANY 4. VI51T "THE JOB5ITE PRIOR TO BID AND EXAMINE THE EXISTING CONDITIONS. UNLE55 NOTED OTHEKWI5E, INDICATING THE CIRCUIT NUMBERS CONTAINED WITHIN. LOCATION WITHIN THE ROOM , A5 REQUIRED BY CODE. R INCLUDE ALL MATERIAL AND LABOR FOR COMPLETE INSTALLATION. 5. WIRE SHALL BE COPPER UNLE55 NOTED OTHERWISE ON THE PLANS, HEAT 5. LABEL EACH COMMUNICATION SYSTEM JUNCTION BOX WITH AN INDELIBLE 2. LIFE SAFETY LIGHTING AND SIGNS SHALL BE PROVIDED WITH UNIT 5. COORDINATE THE INSTALLATION WITH OTHER TRADES "TO MAINTAIN PROPER AND MOISTURE RESISTANT, TYPE THWH WITH A GOO VOLT RATING. MARKER A5 TO THE SYSTEM TYPE WITHIN , SUCH AS "F/A" FOR FIRE ALARM. BATTERY EQUIPMENT AND CONNECTED TO 1 HE ROOM LIGHTING CIRCUIT WORKING CLEARANCES AND FIRE RATINGS. VERIFY EQUIPMENT RATINGS PRIOR -TO 6. MIf�IIMUM WIRE SIZE 15 # 12 FUR POWER CIRCUITS. RUN # 10 MINIMUM AHEAD OF ALL SWITCHING. ZING. ORDERING MATERIALS. CHECK VOLT/AMP RATINGS, AND MOUNTING/TRIM HOMERUN FOR CIRCUITS LONGER THAN FIFTY FEET AS MEASURED FROM REQUIREMENTS. IF THERE ARE INCON515TEN515TIE5, GET CLARIFICATION. THE LAST JUNCTION BOX. PRIOR TO ORDERING MATERIAL5 OR ROUGH -IN. 7. WIRING DEVICES SHALL BE 20 AMP RATED, 120V HEAVY DULY SPECIFICATION GRADE GROUNDING TYPE=, NEMA TYPE 5-20. G. CONTACT THE UTILITY COMPANIES PRIOR TO BID AND INCLUDE THEIR FEE AND OTHER REQUIREMENT5 IN THE BID. IF THE5E FEES ARE NOT AVAILABLE (5. FOR DEVICES LOCATED ON OPPOSITE SIDES OF A FIRE RATED WALL, AT BID TIME, THEN BE SPECIFIC IN EXCLUDING -THEM. SPACE DEVICES NOT LE55 THAN 24 INCHES APART. SECTION I G710 - SPECIAL 5Y5"TEM5 RACEWAYS I . FROM EACH COMMUNICATIONS OUTLET BOX PROVIDE A 3/4 -INCH CONDUIT TO ACCESSIBLE CEILING SPACE. 2. FROM FLOOR BOXES PROVIDE A UNE -INCH RACEWAY TO ACCESSIBLE CEILING SPACE. TWO FLOOR BOXES MAY BE CONNECTED VIA TWO ONE - INCH CONDUITS. IN THIS CONDITION PROVIDE TWO ONE -INCH CONDUITS 5TUBBED-UP FROM THE LAST FLOOR BOX TO ACCESSIBLE CEILING SPACE WITH NYLON PULL S fr.ING. - 3. FOR EACH CONDUIT STUB TO ACCESSIBLE CEILING, PROVIDE NON-METALLIC END BUSHINGS AND NYLON PULL STRING. Project No. 17-049 Sheet No. Eluo 1 •. I . RELOCATE EXISTING FIXTURE AS SHOWN ON RENOVATION PLAN. NORTH 2. DISCONNECT AND REMOVE EXI5-FING FIXTURE. TO HEAD IN TIE IN POINT. PROVIDE QUAD RECEPTACLE AND GROUNDING. LIGHTING RENOVATION KEY NOTES: U NORTH 1. PROVIDE AND INSTALL A POWER PACK AND OCCUPANCY SENSOR TO CONTROL KECEPTACLE5 MARKED WITH A "C" (SEE POWER RENOVATION PLAN) AND LIGHT5 IN THI5 AREA. 2. CONTINUE CI RCU IT TO CONTROLLED RECEPTACLE MARKED WITH A "C" ON POWER RENOVATION PLAN . 3. SIGN CIRCUIT 15 EXISTING. PROVIDE AND INSTALL TIMECLOCK IF ONE NOT PRESENT. 05 LEVITON (OR EQUAL) SUPER DUTY POWER PACK AND OCCUPANCY SENSOR TO CONTROL PP RECEPTACLES AND LIGHTS IN THIS ROOM EX EXISTING FIXTURE -REWIRE AS SHOWN R EXISTING FIXTURE RELOCATED TO THIS SPOT -WIRE AS SHOWN NORTH POWER 5Y5TEM5 RENOVATION NOTE5: 0 TO HEAD IN TIE IN POINT. PROVIDE QUAD RECEPTACLE AND GROUNDING. . CONNECT TO LIGHTING CIRCUIT WITH CONTROL. SEE: LIGHTING PLAN. 2. NEW RECEPTACLE ON A NEW CONTROLLED CIRCUIT VIA OCCUPANCY 5EN50K. 05 LEVITON (OK EQUAL) 5UPEK DUTY POWER PACK AND OCCUPANCY SEN50K TO CONTROL CONTRACTOR TO PROVI DE MARKT NG5 A5 KEQU I RED I N A5HAE STAN DARD 90. 1. PPI RECEPTACLES AND LIGHT5 IN TH15 ROOM PANEL: A EXISTING VOLTAGE: 120/208V MAIN: 200A MOUNTING: PHASE: 3 SMD/MLO: MLO MANUFACTURER: SPACES: 42 AIC: EXIST SOURCE: TYPE: SECTION: CAPACITY 72KVA CKT. EQUIPMENT KVA COND WIRE CB POLE POLE CB WIRE COND KVA EQUIPMENT CKT 1 N WALL REC 1 EXIST EXIST 20 1 3 90 EXIST EXIST 8.6 AC 2 3 WNDOW REC 1 EXIST EXIST 20 1 5 ...... ... .. .. 90 EXIST EXIST 8.6 4 5 S INA LL REC 1 EXIST EAST 20 1 :::.;i`:�'" �;i:;'1'" 90 EXIST EXIST 8.6 c- 7. 7 PHONE REC 0.5 EXIST EXIST 20 1 1 20 EXIST I EXIST 1.2 OFFICE LIGHTS 8- 9 OFFICE COMPUTER 1 EXIST EXIST 20 1 1 20 EXIST EXIST 1 TRACK LIGHTS 10 11 FLOOR LITES W END 1.2 EXIST EXIST 20 1 1 20 EXIST EXIST 1 BACK OFF REC 1; 13 SPARE "20 EXIST EXIST 20 1 1 20 EXIST EXIST 0.5 CAMERA REC 14 15 BACK DOOR REC 1 EXIST EXIST 20 1 1 20 EXIST EXIST 0.6 CASH REG REC 16 '17 SPARE ' " COUNTER REC 20 21 :1't 20 1 1 20 EXIST EXIST 0.6 CASH REG REC 18 19 NITELTS/&,ENERG 0.5 EXIST EXIST 20 1 1 20 EXIST EXIST 0.6 CASH REG REC 20 21 SIGN 1.2 EXIST EXIST 20 1 1 20 EXIST EXIST 0.6 CASH REG REC 2 23 NO LABEL 1 201 EXIS , 20 1 1 20 EXIST EXIST 0.6 CASH REG REC 24 25 CASH REG REC 0.6 EXIST EXIST 20 1 1 20 EXIST EXIST 1.5 INSTA HOT 26 27 SPARE ci1.S`•'`K 32 20 1 1 20 EXIST EXIST 1.5 INSTA HOT 213 29 BLANK 34 35 1 20 EXIST EXIST SPARE 30 31 CASH REG REC 0.6 EXIST EXIST 20 1 BLANK 32 33 BLANK 40 BLANK 34 35 BLANK PHASE A 18.792 PROVIDE GROUND BUS AND NEUTRAL BUS PROVIDE TYPE WRITTEN PANEL DIRECTORY 52.4 CONNECTED KVA PHASE B 17.856 BLANK 36 37 BLANK BLANK 33 39 BLANK BLANK 40 41 BLANK BLANK 42 PHASE A 15.6 PROVIDE GROUND BUS AND NEUTRAL BUS PROVIDE -TYPE WRITTEN PANEL DIRECTORY 45.1 CONNECTED KVA PHASE B 16.5 PHASE C '13 GENERAL NOTE5: PANEL: A EXISTING REVISED VOLTAGE: 1201208V MAIN: 200A MOUNTING: PHASE: 3 SMD/MLO: MLU MANUFACTURER: SPACES: 42 AIC: EAST SOURCE: "TYPE: SECTION: CAPACITY 72KVA 1 CKT. EQUIPMENT KVA COND WIRE CB POLE POLE CB WIRE GOND KVA EQUIPMENT CKT 3 iPdt.'^.>;' t:; >.:;1-.;..tt 5 ...... ... .. .. 3::; /.I :'� ? $:. /�,i :xs-i l:,i -.. t,F f`," �,:•.�• l/ 7 ; t Ji"u: I::+ ^. ~'> :::.;i`:�'" �;i:;'1'" >? 3 EXIST EXIS f 1.796 LIGHTS $ 9 SPARE `j;: 0 EXIST EXIST 1.436 LIGHTS 10 11 SPARE 2'. � ,.:1:� . %�:.... ;1' 12 13 EXIST EXIST 1.152 LIGHTS 14 15 a`'. •'r 2 "20 EXIST EXIST 0.9 LIGHTS 16 17 SFA R!," 20 20 EXIST EXIST 1.5 COUNTER REC •18 19 LIGHTS 1.664 314 12 2::i 20 EXIST EXIST 1.5 COUNTER REC 20 21 :1't 1.2 {::; `:;.z " 3>: ,I. 2 2€:r EXIST EXIST 1.5 COUr TER REC 22 23 SVM 1.8 314 12 2= 2;) EXIST EXIST 1.3 REFRIGERA TOR 24 25 RECEPTACLES 1.08 314 '12 ;?O :. €°:, • "f" ; d`: ;';, , ::w'?' 26 27 RECEPTACLES 0.72 3/4 12 f:'. 1 201 EXIS , " , `; i :.,>1;: f t; 1 28 29 3..t (`"<: 2£:1 EXIST EXIST 0.54 RECEPTACLES 30 31 SPARE Z ci1.S`•'`K 32 33 P1 b;g 34 35 36 37 39 40 PHASE A 18.792 PROVIDE GROUND BUS AND NEUTRAL BUS PROVIDE TYPE WRITTEN PANEL DIRECTORY 52.4 CONNECTED KVA PHASE B 17.856 _ PHASE C 15.74 VOLTAGE DROP HA5 BEEN CALCULATED TO MEET FBC ENERGY CON5ERVATION 201-4 FI PTH C405.73. FEEDER CONDUCTOK5 HAVE BEEN SIZED FOR A MAXIMUM VOLTAGE DROP OE 2 PERCENT AT DE51GN LOAD. BRANCH CIRCUIT CONDUCTOR5 HAVE BEEN 51ZED FOR A MAXIMUM VOLTAGE DROP OF 3 PERCENT AT DE51GN LOAD. GENERAL NOTE5 EOR ADDING LOAD5 TO EXI TI 5 N G PA E N L5 1. THE EXISTING PANELS ARE BELIEVED TO HAVE ADEQUATE CAPACITY FOR THE NEW ADDED LOADS, BUT IT 15 PART OF TH15 CONTRACT TO INCLUDE MATERIAL AND LABOR TO MAKE FIELD MEA5UKEMENTS TO CONFIRM. 2. PRIOR TO BEGINNING THE WORK, MAKE CLAMP -ON AMMETER READINGS AT THE PANELS WHERE NEW LOADS ARE TO BE ADDED. MAKE THE5E READING5 DURING NORMAL WORK HOUK5 AND MAKE 5PECIAL EFFORTS TO ENERGIZE ALL CONNECTED LOAD5, INCLUDING LIGHTING, COMPUTEK5, AND HAVC IN HEATING MODE. 3. VEKII=Y THE PANEL FEEDER RATING5 AND If THE MEA5URED LOAD PLUS THE NEW LOAD 15 GREATER THAN 70% OF THE FEEDER CP RATING, THEN CON -FACT THE ENGINEER. DO NOT PROCEED WITHOUT CLARIFICATION FROM THE ENGINEER 4, PROVIDE THE MEA5UREMENT5 TO THE ENGINEER VIA PAX, 5. INCLUDE IN BID LABOR FOR BALANCING THE LOADS IN THE PANELS. G. VERIFY THAT THE CIRCUIT 5HOW TO BE USED 15 A CIRCUIT THAT WAS DELETED DURING DEMOLITION FOR TH15 TENANT, PLUMBIONG PLAN SCALE: 1/4" = 1'-0" FIXTURE UNIT LOAD VALUES - FLORIDA FBC TABLE E'103.3(2) PLUMBING LEGEND OCCUPANCY TYPE DOMESTIC COLD WATER PIPING i TOTAL FU __...,....., EXIST. DOMESTIC COLD WATER RESIDENTIAL FLUSH TANK - - DOMESTIC HOT WATER PIPING 1.5 3.6 EXIST. DOMESTIC HOT WATER RESIDENTIAL FLUSHOMETER VALVE FW- FILTERED WATER 3.0 8.0 HOT WATER RECIRC RESIDENTIAL. FAUCET --- -- VENT PIPING 1.0 1.4 - - --- WASTE (SANITARY SEWER) COMMERCIAL FAUCET ................ EXIST. WASTE (SANITARY SEWER) 3.0 4.0 -D4--- GATE VALVE RESIDENTIAL FAUCET --D�-- BALANCING VALVE 1.5 2.0 I/I--- CHECK VALVE I RESIDENTIAL FAUCET -O PIPE UP 2.25 3.0 O PIPE DOWN RESIDENTIAL AUTOMATIC -1 HOSE BIBB f 1.4 1.4 --11 WALL CLEAN OUT I 3/8" VALVE Mall, FLOOR DRAIN - 0.25 ® FLOOR CLEANOUT I� I FAUCET Q HUB DRAIN 1.0 1.4 P-1 FIXTURE DESIGNATION COMMERCIAL i GCO GRADE CLEANOUT 3.0 4.0 FCO FLOOR CLEANOUT RESIDENTIAL FAUCET CO CLEANOUT 0.5 0.7 DF DRINKING FOUNTAIN COMMERCIAL FAUCET CW COLD WATER 1.5 2.0 HW HOT WATER COMMERCIAL FAUCET FD. FLOOR DRAIN 2.25 3.0 HD HUB DRAIN RESIDENTIAL MIXING VALVE OD OVERFLOW DRAIN 3.0 4.0 RD ROOF DRAIN COMMERCIAL MIXING VALVE WC WATER CLOSET 1.0 1.4 UR URINAL COMMERCIAL 1" FLUSHOMETER L1 LAVATORY - 10.0 UR URINAL COMMERCIAL 3/4" FLUSHOMEfER �t TIE INTO EXISTING - 5.0 NOT ALL SYMBOLS AND ABBREVIATIONS IN THIS COMMERCIAL ! LEGEND WILL APPEAR IN DRAWING. - PLUMBIONG PLAN SCALE: 1/4" = 1'-0" FIXTURE UNIT LOAD VALUES - FLORIDA FBC TABLE E'103.3(2) FIXTURE OCCUPANCY TYPE CW FU HW FU TOTAL FU BATHROOM GROUP RESIDENTIAL FLUSH TANK 2.7 1.5 3.6 BATHROOM GROUP RESIDENTIAL FLUSHOMETER VALVE 6.0 3.0 8.0 BATHTUB RESIDENTIAL. FAUCET 1.0 1.0 1.4 BATHTUB COMMERCIAL FAUCET 3.0 3.0 4.0 BIDET RESIDENTIAL FAUCET 1.5 1.5 2.0 COMBO FIXTURE RESIDENTIAL FAUCET 2.25 2.25 3.0 DISHWASHER RESIDENTIAL AUTOMATIC - 1.4 1.4 DRINKING FOUNTAIN COMMERCIAL 3/8" VALVE 0.25 - 0.25 KITCHEN SINK RESIDENTIAL FAUCET 1.0 1.0 1.4 KITCHEN SINK COMMERCIAL FAUCET 3.0 3.0 4.0 LAVATORY RESIDENTIAL FAUCET 0.5 0.5 0.7 LAVATORY COMMERCIAL FAUCET 1.5 1.5 2.0 SERVICE SINK COMMERCIAL FAUCET 2.25 2.25 3.0 SHOWER HEAD RESIDENTIAL MIXING VALVE 3.0 3.0 4.0 SHOWER HEAD COMMERCIAL MIXING VALVE 1.0 1.0 1.4 URINAL COMMERCIAL 1" FLUSHOMETER 10.0 - 10.0 URINAL COMMERCIAL 3/4" FLUSHOMEfER 5.0 - 5.0 URINAL COMMERCIAL FLUSH TANK 3.0 - 3.0 WASHING MACHINE RESIDENTIAL AUTOMATIC 1.0 1.0 1.4 WASHING MACHINE COMMERCIAL AUTOMATIC 2.25 2.25 3.0 WASHING MACHINE 15 COMMERCIAL AUTOMATIC 3.0 3.0 4.0 WATER CLOSET RESIDENTIAL FLUSHOMETER VALVE 6.0 - 6.0 WATER CLOSET RESIDENTIAL FLUSH TANK 2.2 - 2.2 WATER CLOSET COMMERCIAL FLUSHOMETER VALVE 10.0 - 10.0 WATER CLOSET COMMERCIAL FLUSH TANK 5.0 - 5.0 WATER CLOSET COMMERCIAL FLUSHOMETER TANK 2.0 - 2.0 HOSE BIBB ANY FAUCET 2.5 2.5 MINIMUM PIPE SIZE & FLOW RATE, FBC 604.3 AND 604.5 FIXTURE MIN. PIPE SIZE FLOW RATE GPM FLOW PRESSURE PSI MAX FLOW RATE DRINKING FOUNTAIN 3/8" 0.75 8 2.0 HOSE BIBB 1/2" 5 2.0 KITCHEN SINK 1/2" 2.5 8 2.2 GPM c@i 60 PSI LAVATORY, RESIDENTIAL 3/8" 2 8 2.2 GPM @ 60 PSI LAVATORY, PUBLIC 3/8" 0.5 8 0.5 GPM @ 60 PSI SINK, SERVICE 1/2" 3 8 2.2 GPM c7 60 PSI WATER CLOSET, FLUSH TANK 3/8" 3 20 1.6 GAL URINAL 3/4" 12 25 1.0 GAL NEVI,' PLUMBING FIXTURES ID DUAN. FIXTURE TRAP SIZE FU COUNT SS 1 SERVICE SINK 1.5" 2.0 TOTAL 2.0 PLUMBING PLAN NOTES: 1. ALL WORK SHOWN SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE AND LOCAL BUILDING ORDINANCES. 2. THE LICENSED CONTRACTOR SHALL BE RESPONSIBLE FOR CERTIFYING ALL EQUIPMENT DESIGN REQUIREMENTS (I.E. VOLTAGE, WATER, DRAINS, GAS CONNECTIONS, ETC.) WHEN REQUIRED FOR APPROVED OPERATION, ALL EQUIPMENT SHALL BE FURNISHED WITH ALL REQUIRED ACCESSORIES. 3. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND FREE FROM DEFECTS WITH THE FACTORY WARRANTY. PRODUCTS SHALL BEAR RESPECTIVE A.S.T.M. STANDARD LABELS AND INSTALLED AS PER LISTING UNDER SUCH. 4. INSTALL SANITARY LINES SLOPE OF NOT LESS THAN 1/8" PER FOOT 3"-6" AND 1/4" PER FOOT 1:5"- 2.5". 5. INSTALL PIPING AND EQUIPMENT ALLOWING ADEQUATE ACCESS FOR SERVICE TO VALVES AND EQUIPMENT OF OTHER TRADES. Pt )VIDE U.' L. LISTED ACCESS PANELS IN WALLS AND CEILING WHERE ACCESS IS REQUIRED. 6, INSTALL CLEAN -OUTS AS INDICATED ON DRAWINGS AND EVER`( 75 FEET, AT BASES OF STACKS, AND CHANGE OF DIRECTION. 7. SANITARY, VENT, AND RAIN WATER LEADER PIPING SHALL BE SCHEDULE 40 PVC SOIL PIPE WITH DRAINAGE TYPE FITTING, SOLVENT WELDED. PRIME FITTINGS AND PIPE ENDS PRIOR TO WELDING, EXCEPTION: IN AIR CONDITIONING PLENUMS, i.e. MECHANICAL ROOMS, CAST IRON PIPING SHALL BE USED. 8, DOMESTIC WATER PIPE SHALL BE TYPE L ABOVE GROUND AND TYPE K BELOW GROUND. SOLDER FITTINGS USING LEAD-FREE SOLDER, AVOID JOINTS BELOW SLABS OR INSIDE WALLS WHENEVER POSSIBLE. 9. PROVIDE EXPANSION AIR CHAMBERS OF 20 PIPE DIAMETERS BUT NOT LESS THAN 12". INSTALL AT EACH FIXTURE, GROUP OF FIXTURES, RISERS AND END OF SUPPLY LINES. 10. ISOLATE COPPER PIPING FROM DISSIMILAR METAL, MASONRY OR CONCRETE WITH FOAM PLASTIC, FIRE RETARDANT INSULATION OR SIMILAR METHODS APPROVED BY LOCAL JURISDICTION. 11. PROVIDE PIPE SLEEVES FOR ALL CEILING, FLOORS, OR WALL PENETRATIONS. PACK WITH FIRE RETARDANT CAULKING IN CONFORMANCE TO U.L. SPECIFICATIONS. . 12. PLUMBING FIXTURES SHALL BE FIRST GRADE VITREOUS CHINA CONFORMING TO ANSI STANDARDS. FURNISH TRAPS, VALVES, AND ALL TRIM TO COMPLY WITH ALL CODES AND ORDINANCES. AMERICAN STANDARD OR EQUAL. PROVIDE READILY ACCESSIBLE CONTROL VALVES AND ACCESS PANELS. PROVIDE 2 SETS OF MAINTENANCE AND OPERATION MANUALS. 13. STIEBEL MINI 2-1 TANKLESS HOT WATER HEATER. 120V / 15A IN BREAK ROOM 2295 S. HIAWASSEE RD. SUITE 304 ORLANDO, FLORIDA 32835 P H : 4 0 7 . 2 9 8 - 5 0 2 0 FX:407.298-5030 Owner:: Kent Kirton e Architect of Record: John W. Burt - AR93163 Revisions- 2 11 -01 -17 -PLAN REVIEW IM t -U_ Cd �d U0 co 0. e Architect of Record: John W. Burt - AR93163 Revisions- 2 11 -01 -17 -PLAN REVIEW CITY OF SANFORD BUILDING & FIRE PREVENTION �J 1 PERMIT APPLICATION 1 ,°' Ito?, Q � )A � Bldg. Permit #117-27 7 7 Application No: Doculilellte(l Constl'uctiou Value: S 2, 234. 00 Jol) Address: 701 TOWNE CENTER BLVD (STE 2.11) llistorie Dist01 rict: Yes ❑ No 0 - Pat -eel Pat -eel ID: 29-19-30-503-0000-0020 Residential❑ C01Illuercial El Type of Work: Neiv 0 Addition ❑ : Alteration ❑ Rcpair ❑ Delno ❑ Chalige cif Use ❑ Move ❑ Add/ 'relocate seven sprinklers per new tenant revisiori `(7 ` Eire sprinkler Description of Work: heads ,y ^L) Plan Review'Contact Person 1/ P111011e: 407-877-5560 MN James BaliusProject Manager Title: Fax: 407-656-8026 Entail: permitting@wayrtefire.Qom Property Owner Information Nallte MSKP GA'T'EWAY 14LC Pholle: 4500 PGA BLVD STE 400 Strect: ..1. Resideut of property? City, Statc.'Lip': PALM,,BEACH,:GARDENS, FL +`33418 gyp; •_, .�,+ i Contractor Information Wayrie Automatic Fire'Sprinklers, ,Inc 407-798-7598 Name PIIU1IC`. Street: 222 Capitol Court Fax: 407-656-8026 City, State Lip: Ocoee, FL 34761 State License No.: FPC14-000057 Architect/Engineer Information Nallle: N/A P11o11C: Street: City, St, Zip: E-mail: Bonding Colllpauy: N/A Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE'IO RECORD A NOTICE OF COyINIENCEIYIENT MAY RESULTIN YOUIt PAYING 'I'1VICE FOR INIPROVEtINIENT'S TO YOUR PROPERTY. A NOTICE OF CONINIENCEINIENT MUST BE RECORDED AND POSTED ON THE J( )'_SITE- BEFORE THE FIRST INSPEC'T'ION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUt2 LENDER .OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE: OF CONINIENCENIENT. Application is hereby made to obtain a pet'mit`to (lo the work and iusttillatious tis indicated. l certify Mutt no work or iustdlatioii has commenced I)rior to the issuance of a permit and that all work will be performed to meet standards of till laws rogulatinb constt' IC60n in this jurisdiction. I understand that a separate perulit must be secures( for electrical work, pluutbiug, signs, wells, pools, furnaces, boilers, he<I(ers, tanks, and air conditioners, etc. FBC (lie code in effect as of that dale; 5111 G:ditioa (2111=1) Florida Building Code )o© Fze- Revised; June 30, 2015 �Gt " l'ennit t\I plication • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13. • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. • ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). • ALL HANGERS AND ANY REQUIRED BRACING SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13, MANUFACTURER'S INSTRUCTIONS AND THEIR LISTING. • ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY IS TO USE HILTI FS ONE OR STI LCI. • UNDERGROUND MAINS AND LEAD-INS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SYSTEM. • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. • ALL SYSTEMS SHALL BE TESTED FOR 2 HOURS AT 200 PSI OR 50 PSI GREATER THAN MAXIMUM SYSTEM WORKING PRESSURE, WHICHEVER IS GREATER. • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. �► ALL WIRING OF DEVICES (FLOW SWITCHES, TAMPER SWITCHES, COMPRESSORS. ETC) IS BY OTHERS. CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM IS BY OTHERS. + ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. +� ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER SYSTEM IS BY OTHERS, • HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. • FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED NOT LESS THAN 18" AND NOT MORE THAN 48" ABOVE THE LEVEL OF THE ADJACENT GRADE. • QUICK RESPONSE SPRINKLERS SHALL BE USED IN ALL LIGHT HAZARD AREAS. • SPARE SPRINKLERS OF EACH TYPE (EXCLUDING DRY) SHALL BE PROVIDED ON THE PREMISES AS FOLLOWS: o LESS THAN 300 - 6 SPRINKLERS 0 300 TO 1000 - 12 SPRINKLERS o OVER 1000 - 24 SPRINKLERS �► REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES, • SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o ANY PORCHES, BALCONIES OR OVERHANGS THAT ARE NON-COMBUSTIBLE AND ARE NOT USED FOR STORAGE. • CORRIDORS THAT ARE NON-COMBUSTIBLE IN CONSTRUCTION AND AT LEAST 50% OPEN. o AT THE TOP OF ALL ELEVATOR SHAFTS WHERE THE CAR ENCLOSURE MEETS THE REQUIREMENTS OF ASME A17A o AT THE BOTTOM OF ENCLOSED NON COMBUSTIBLE ELEVATOR SHAFTS THAT DO NOT CONTAIN COMBUSTIBLE HYDRAULIC FLUID. • WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 13 INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS. AND INSPECTION TAGS AS REQUIRED BY FS 633. W1 NFPA 13 2010 GENERAL NOTES SCALE: NONE F" spa acw w Yw. FIRE SPRINKLER DETAILS SCOPE OF WORK DETAILS/NOTES; WAFS TO RELOCATE & ADD SPRINKLERS FROM EXISTING FIRE SPRINKLER SYSTEM DUE TO NEW TENANT REVISIONS, LEGEND 1' 90' ELL EXISTING PIPE TAX MAX. 1' 90' ELL NEW PIPE ly' V DI TEE NEW HANGER 3' MIN. T -T (PER PLAN) MECHANICAL TEE 15'-0' MAX. MT NEW SPRINKLER HEAD 1/2' 5.6 165° CHROME SR RECESSED PENDENT SHEET # RELOCATED SPRINKLER HEAD IOCCUPANCY; R* REMOVED AND PLUGGED SPRINKLER HEAD - TOTAL PER FLOOR NOT IN SCOPE OF CONTRACT 7 TOTAL THIS SHEET WAFS POLICY ON REUSING SPRINKLERS NFPA 13 INDICATES THAT ALL SPRINKLERS SHALL BE NEW, IN THE 2013 EDITION, ALTHOUGH NOT YET ADOPTED, SECTION 6.211 INDICATES 'WHEN A SPRINKLER HAS BEEN REMOVED FOR ANY REASON, IT SHALL NOT BE REINSTALLED', WAFS POLICY IS TO REPLACE ANY SPRINKLER THAT HAS BEEN REMOVED FROM THE FITTING TO WHICH IT WAS ATTACHED. IF THE SPRINKLER REMAINS IN THE FITTING TO WHICH IT WAS INSTALLED AND THE SPRINKLER IS PROTECTED FROM DAMAGE THROUGHOUT THE PROCESS, THAT SPRINKLER MAY REMAIN, 00686N ALL MATERIAL APPLICABLE TO THIS PROJECT WILL BE INDICATED WITH A (�/ ) ❑ ALL PLASTIC PIPE 34" THROUGH 212 SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F-442. LI ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. ❑ ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING 'ONE STEP' 500 CEMENT, CPVC PIPE SHALL BE ALLOWED TO BE USED IN ORDINARY HAZARD ROOMS OF 400 SQUARE FEET OR LESS OF OTHERWISE LIGHT HAZARD OCCUPANCIES (NFPA 13 SECTION 6.3.6.2 OR NFPA 13P SECTION 5.2.2.3). ALL 1' TO 2" THREADED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-135 OR A-795, ACCEPTABLE PIPE BRANDS ARE WHEATLAND 'MEGATHREAD', ALLIED 'DYNATHREAD', BULL MOOSE TUBE 'EDDYTHREAD' AND WELDED TUBE -BERKELEY 'STEADY -THREAD'. ALL PIPE SHALL BE CPVC COMPATIBLE. ALL 1" TO 2" THREADED GALVANIZED PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A-795 OR ASTM A-53. ❑ ALL 1- TO 2" THREADED BLACK STEEL PIPE SHALL BE SCHEDULE 40 UL LISTED/FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE PIPE MANUFACTURERS ARE WHEATLAND. ALLIED, BULL MOOSE TUBE AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC COMPATIBLE. ❑ ALL 1!4" TO 4" GROOVED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A795. ACCEPTABLE BRANDS ARE BULL MOOSE 'EDDYFLOW', WHEATLAND 'MEGA -FLOW', ALLIED 'DYNA-FLOW' AND WELDED TUBE -BERKELEY 'STEADY -FLOW'. ALL PIPE SHALL BE CPVC COMPATIBLE. ALL 114' TO 4' GROOVED BLACK STEEL PIPE SHALL BE SCHEDULE 10, UL LISTED/FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE MANUFACTURERS ARE BULL MOOSE, WHEATLAND, ALLIED AND WELDED TUBE -BERKELEY, ALL PIPE SHALL BE CPVC COMPATIBLE. ❑ ALL GROOVED STEEL PIPE 6" AND LARGER SHALL BE UL LISTED/FM APPROVED SCHEDULE 10 AND MANUFACTURED IN ACCORDANCE WITH ASTM A-135. ❑ ALL GROOVED STEEL PIPE P4" AND LARGER SHALL BE SCHEDULE 10 HOT DIPPED GALVANIZED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ALL STEEL PIPE SHALL HAVE A CORROSION RESISTANCE RATIO (CRR) OF NOT LESS THAN 1.0 PER WAFS STANDARDS. ALL BLACK THREADED FITTINGS SHALL BE DUCTILE IRON CLASS 150 OR CLASS 300 ANSI 816.3, CAST IRON CLASS 125 OR CLASS 250 ANSI 816.4 OR MALLEABLE IRON CLASS 150 OR CLASS 300 ANSI 816.3. ❑ ALL GALVANIZED THREADED FITTINGS SHALL BE MALLEABLE IRON CLASS 150 OR CLASS 300 ANSI 816.3 WITH GALVANIZED COATING IN ACCORDANCE WITH ASTM A-153. ❑ ALL WELDED OUTLETS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ANSI 816.11. ❑ GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. ❑ ALL GALVANIZED GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. GALVANIZED COATING SHALL BE IN ACCORDANCE WITH ASTM A-153. ❑ ALL GROOVED STEEL PIPE SHALL BE ROLL GROOVED PER PIPE MANUFACTURER REQUIREMENTS. PIPE AND FITTINGS GENERAL NOTES SCALD NONE Avtown ic, Fry SwWdere, rlo. \\Wafsstorage\wafsdata\Design\plots\_Ocoee Service\87500-90000\87688 Gateway Inn\FP Drawings\87688 FP1.dwg, FP1, 10/13/2017 2:56:00 PM PENDENT SPRINKLER W/ ESCUTCHEON CEILING SPRINKLER RETURN BEND W/ THREADED SUP PLY C>_\V SCALE MUNE Autemetic Fire Sprinklers, Inc. 00583N A B C SPRINKLER HEAD 4I 'M STEEL PIPE I SPRINKLER HEAD HANGER RING TABLE 3 - MAXIMUM SUPPORT SPACING 1' X REQ'D LEN. A T -T (PER PLAN) 1' 90' ELL 1' TAX MAX. 1' 90' ELL 1' X 0-4 T -T ly' V DI TEE 1' X REQ'D LEN, 3' MIN. T -T (PER PLAN) SUPPLY LINE 15'-0' MAX. 3' MIN. / COUPLING EDUC PENDENT SPRINKLER W/ ESCUTCHEON CEILING SPRINKLER RETURN BEND W/ THREADED SUP PLY C>_\V SCALE MUNE Autemetic Fire Sprinklers, Inc. 00583N A B C SPRINKLER HEAD 4I 'M STEEL PIPE I SPRINKLER HEAD HANGER RING TABLE 3 - MAXIMUM SUPPORT SPACING NOM, PIPE SIZE A Bx C 1' TAX MAX. 12'-0' MAX. 3' MIN, ly' CA' MAX, 12'-0' MAX. 3' MIN. 1i ' TO 8' T-0' MAX, 15'-0' MAX. 3' MIN. MCNTY PLAN SCALE I NONE oMAXIMUM SUPPORT SPACING FOR STEEL PIPE STEEL PIPE HANGER SPACING Fire Sprinklers, Inc. SCALE, NONE 00588N r:' 00 TOP BEAM CLAMP %' FOR Y4' TO 4' PIF Y2' FOR 5' TO 8' PIPI ALL THREAD ROD — ' FOR Y4' TO 4' PIPE ' FOR 5' TO 8' PIPE HANGER R (SIZED TO PI -R ICE HANGER *O1 RING HANGER FOR 3/4" TO B" PIPE (I BEAM) AYNE SCALEI NONE Automatic R'' Sp*&"' bw- 00197N EXISTING ACCOUSTICAL CEILING GRID TO REMAIN AT 10'-0" TOP BEAM CLAMP Y8' FOR '' TO 4' PIPE DR 5' TO 8' PIPE ORLANDO SERVICE DEPT74O ' F DESIGNER REFERENCE DETAIL VEW y ALL THREAD ROD ' FOR Y4' TO 4' PIPE LUL,r\I1iU 1 (INCLUDED HANGER RING (SIZED TO PIPE) W/ CLAMP) HANGER *01 RING HANGER FOR 3/4" TO B" PIPE (BAR JOIST) FWAM SCALE, NONE Are Ip''t'I&m bw 00198N BOT STEEL @ 13-2 e`vieWed Robf Sanford f=ire D n.q#p-: _ _- *4110. FIDE SPPINKLEP PL/\N SCALE : 1/8" = 1 '-0" 2,92O SO. FT. I 81 16' SCALE i AdOZ) IMPORTANT OWNER INFORMATION THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADDPTED EDITION (EITHER STATE OR LOCAL) OI' MAPA 25 AS N¢ APPLICABLE STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE U' WATER BASED FIRE PROTECTION SYSTEMS. PER SECTION 1.1, TME RESPONSIBILITY FOR PROPERLY MAINTAINING A WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE BUILDING OWNER HAS NUT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT FAMILIAR WITH THE OPCRATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT THE NEAREST OFFICE Or WAYNE AUTOMATIC FIRE SPRINKLERS. INC. CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLERPIPING SYSTEMS HAVE BECK USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVCPRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TD THEIR OUTSTANDING CDRROSION RESISTANCE. OCCASIONALLY, HOWEVER CPVC CAN BE DAMAGED BY COWACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS QEE SOME VIRES, FLUX, PETROLEUM BASED PRODUCTS. ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WVW.SYSTEMUMPAT IDLE CUM CC) ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS. SPECIFIC IR IIEG N�TTIM IES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. <V AFS) AS INSTRUMENTS Or SERVICE, THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT. OR OTHERS, ON EXTENSION OF THIS PROJECT, DR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE INFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATYaRNETS rEES RESULTING FROM ANY SUCH PERMISSIONS. GRAPHICS ELEMENTS NOTE FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS, THE FIRE SPRINKLER ENGINEER IS DNLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER DRAWINGS DEPICTING FIRE SPRINKLER I ESCOPES OF WORK. REFER TO APPROVED ARCHITECTURAL, STRUCTURAL. HER OR CIVIL DRAWINGS FUR AUTHORITATIVE EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZCD IN FIRE SPRINKLER DRAWINGS OR DETAILS DESIGN CRITERIA SYSTEM / DESIGN AREA 1! HAZARD CLASS I OF SPRINKLERS N DESIGN AREA MINIMUM DENSITY DESIGN AREA S,F, PSI REQ'D 2 BASR GPM REQ'D 2 BASR PSI REOT 8 TEST GPM REQ'D 2 TEST ELEVATION a H1GEST SPRINKLER HOSE INSIDE/OUTSIDE DOMESTIC DEMAND SPRINKLERS SPACING ER SUPPLY INFORMATION URE SSURE FINGPM ACTUAL FIRE PUMP SIZE; GPM a PSI HYDRANT ELEV, DATE Or -TEST IME Of ST [SHEET TAL A/SI NUMBER OF PORTS FLOWED D BY�ULT TE- IUN AHJ, CITY OF SANFORD DESIGN CRITERIA SYSTEM / DESIGN AREA 1! HAZARD CLASS I OF SPRINKLERS N DESIGN AREA MINIMUM DENSITY DESIGN AREA S,F, PSI REQ'D 2 BASR GPM REQ'D 2 BASR PSI REOT 8 TEST GPM REQ'D 2 TEST ELEVATION a H1GEST SPRINKLER HOSE INSIDE/OUTSIDE DOMESTIC DEMAND SPRINKLERS SPACING SYMBOL MAXIMUM MINIMUM COMMENTS • 15' 6' DEFLECTOR V TO 12' MAX BELOW CLG, [SHEET TAL A/SI 7 TE- 10-9-17 AHJ, CITY OF SANFORD CONTRACT # 87688 - 1/2' 5.6 165° CHROME SR RECESSED PENDENT SHEET # _FP1 IOCCUPANCY; ,QUANTITY--, SPRINKLERS SYMB, IST 2ND 3RD 4TH SIN SIZE K ITEMP MODEL • 1 R1015 1/a' 5.6 165' RELIABLE G CHROME SR RECESSED PENDENT [SHEET TAL A/SI 7 TE- 10-9-17 AHJ, CITY OF SANFORD CONTRACT # 87688 - 1/2' 5.6 165° CHROME SR RECESSED PENDENT SHEET # _FP1 IOCCUPANCY; CONSTRUCTION TYPE; IIB B - TOTAL PER FLOOR 7 TOTAL THIS SHEET DATE SUBMITTALS By XX/XX/XX -- - N0. I DATE REVISIONS BY I`.. I XX/XX/XX I -- — W WAYNE Automatic Fire Sprinklers, Inc. MAIN OFFICE — ORLANDO. FLORIDA 222 CAPITOL COMT OCOEE FLORIDA 34761 PHONE (407) OW -3030 FAX: (407) BBS -8026 JAQC90NVLL.E RL TAwA. FL POWAM DEAM FL 0326 DISTRBUTION AVE. WEST 3228 CHERRY PALM DRIVE 3121 NW 16TH TERRACE JACKSONVLLE. FL 32258-2745 TAMPA. FL 33619-6337 POWANO BEACK FL 33054-1408 PHONE (904) 268-3030 PHONE (813) 630-0303 PHONE,(854) 917-3030 FAX. (904) 268-0724 FAX 0813) 830-0312 FAX: (954) BT7-9424 FT. MYEW FL CONCOM NC STATE LICENSES. 4683 LAREDO AVE. 4370 MOTORSPORT DRIVE NC SPRINKLER 29745 FT. MYERS, FL 33905-4624 CONCORD, NC 28027-6977 NC ALARM 29222 SP LV PHONE: (P_39) 433-30:10 PHONE (7D4) 782-3032 SC SPFWWJ-EFL TI6 FAX: (239) 433-3263 FAX: (704) 795-8836 SC ALAFOA 3366 MSKP GATEWAY, LLC F 101 TOWN CENTER BLVD. STE 211 SANFORD, FL. MSKP GATEWAY, LLC 995 N SR 434 SUITE 2720 ALTAMONTE SPRINGS, FL. 32714 TITLE; FIRE SPRINKLER AWN BY- JAMES BALILIS [SHEET TAL A/SI 7 TE- 10-9-17 AHJ, CITY OF SANFORD CONTRACT # 87688 CENTER OF TILE JDB7 ❑ YES JNO I CENTER ON FIXTURES JOB? ❑ YES JNO SHEET # _FP1 IOCCUPANCY; CONSTRUCTION TYPE; IIB B CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Bldg. Permit #17-2777 n ` Documented Construction Value: $ $2,687.610 Jou Address: 1.0' Towne Center Blvd. (Suite 211) Historic District:'Yes ❑ No 0 Parcel ID: 28-19-30-503-0000-0020 Residential ❑ Conutlercial [ Type of Work: New IN Addition ❑ Alteration ❑ Repair ❑ Demo 0 . Change of Use[,:]. °Move ❑ Description of Work: Add alarm devices per new tenant revisions. Plan RevielV Contact Person: Brandon Lopp _'Title: Project Manager Phone: 321-221-2075 Fax: 407-656-8026 Linail: permitting Cg).waynefire.com Property Owner Information Name MSKP Gateway LLC Phone: Street: 4500 PGA"Blvd ;Suite #400 Resident of property? : No Cita, State Zip ,' Palm Beach'Gardens, FL',,33418 " Contractor Information Name Wayne Automatic Fire Sprinklers, Inc. Phone: 407-877-5557 Street: 222 Capitol Court Fax: 407-656-8026 City, State Zip: Ocoee, FL 34761 State License No.: EF20001320 Architect/Engineer Information Name: N/A Phone: Street: Fax: 0.j - Cit y, City, St, Zip: E-mail: Bonding Company: N/A Address: - Mortgage, Lender N/A Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAX RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPER'L'Y. A NOTICE OF COMMENCENIENT NtOST BE RECORDED AND POSTED ON -111& -JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR,, LENDER OR AN A'TT'ORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a pertiiit`to do the work and installations as indicated. L certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FITC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5u' Edition (2014) Florida Building Code Revised: June 30, 2015 Ile 1 nit Application l FIRE ALARM SYSTEM INPUT/OUTPUT MATRIX I DESCRIPTION DODO©©DODO©� JUNCTION BOX MODEL I QTY. X07 / STROBE LIGHT CM = CEILING MOUNT 80"-96" CEN. AFF. (OR)CEILING-SEE PLAN 4 » SQUARE SCRL MMMMnK3MMMMMaO CONDUIT HORN/STROBE LIGHT CM = CEILING MOUNT 80"-96" CEN. AFF. (OR)CEILING-SEE PLAN » 4 SQUARE PC2RL 4 3 M I..'-fREEWIRE MOMMnnMMMMMno 43K 1 INSTALL PER NATIONAL FIRE ALARM CONTROL PANEL 6'-0"AFF TO TOP ENCLOSURE 5208 © ELECTRIC CODE mmmmooMMMMMn© 6'-0"AFF TO TOP ENCLOSURE 5495 1 SECTION A—A jacket. MOUNT AUDIBLE & C. Type RG 59/U coaxial cable with polyethylene (PE) insulation and assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition MOUNT ON AN Designs in the g e UL Fire Resistance Directory and shall include the having a max OD of 5 8 in. 9 / VISUAL DEVICES ON E. Through Penetrating Products* — Max three copper conductor 9 9 PP A. Studs Wall framing may consist of either wood studs or steel APPROVED BOX AIR SUPPLY DIFFUSER RETURN AFC CABLE SYSTEMS INC APPROVED BOXES. CONDUIT spaced max 24 in. OC, annulus, flush with each end of the steel sleeve or wall surface. Fill AIR OPENING OR OUTER EDGE material installed symmetrically on both sides of the wall. A min 5/8 in. or tapered edges. The gypsum wallboard type, thickness, number thickness of sealant is required for the 1 or 2 hr F Rating . An of layers, fastener type and sheet orientation shall be as specified n OF CEILING FAN BLADE ooMMOOnnnnMMn Resistance Directory. Max diam of opening is 4 in. beyond surface of wall. The F Rating of the firestop system is equal to the fire rating of SMOKE/HEAT DETECTOR CONDUIT SEAL W/ BUSHING *Bearing the UL Classification Mark ( aK3MMMMnnnnMMo Reproduced b HILTI, Inc. Court of C', ❑���aRe M Y nc. Underwriters Laboratories, Inc. FIRESTOP SYSTEMS November 27, 1000 ( I IC SILICONE l V J Poge: 1 of 2 1 CEILING 0'-4' MINIMUM 3'-0' MINIMUM 0'-6' MINIMUM SEAL W/ f CEILING 0'-4' MINIMUM LOCKBOX OUTSIDE ® 1 HORN/STROBE _l ©THORN SILICONE STROBE OR HORN/STROBE MAXIMUM 4' BOX SMOKE/HEAT) DETECTOR POWER SUPPLY OR VOICE EVAC/ f ONTROL PANEL STROBE 10'-0' SPEAKER/STROBE J A.F.F. 4' DEEP BOX HINGED SIDE SEAL TIGHT WH1P� WEATHERPROOF 96' MAXIMUM A.F.F. HORN/STROBE TOP OF DEVICE 7ANKIATM (FREEZER ONLY) _ 80' MINIMUM A.F,F. TO MANUAL PULL STATION BOTTOM OF DEVICE TMANUAL PULL 4' BOX W/ 5'-6' STATION SINGLE GANG 5'-0' MAXIMUM SWITCH RING 3'-8' (3'-6' MINIMUM, 4'-(' MAXIMUM) INISHED FLOOR NSA 72 AND ADA DEVICE NSTALLAT13N FiE0l11111`111EBfTS SCALE, NONE A I*. OD691L FIRE ALARM SYSTEM INPUT/OUTPUT MATRIX � f.1 E J L7 E J � s i R`a NN i J• Nu NC J• Nt.7 NES I ft"d*_b. FIRE ALARM SYMBOL LEGEND SYMBOL I DESCRIPTION DODO©©DODO©� JUNCTION BOX MODEL I QTY. X07 / STROBE LIGHT CM = CEILING MOUNT 80"-96" CEN. AFF. (OR)CEILING-SEE PLAN 4 » SQUARE SCRL MMMMnK3MMMMMaO • FL BUILDING HORN/STROBE LIGHT CM = CEILING MOUNT 80"-96" CEN. AFF. (OR)CEILING-SEE PLAN » 4 SQUARE PC2RL 4 3 M _ _ MOMMnnMMMMMno 43K 1 ac FIRE ALARM CONTROL PANEL 6'-0"AFF TO TOP ENCLOSURE 5208 © . - _.. , mmmmooMMMMMn© 6'-0"AFF TO TOP ENCLOSURE 5495 1 SECTION A—A jacket. 1. Wall Assembly The 1 or 2 fire—rated gypsum wallboard/stud wall C. Type RG 59/U coaxial cable with polyethylene (PE) insulation and assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition PVC jacket. D. Multiple fiber optical communication cable jacketed with PVC and Designs in the g e UL Fire Resistance Directory and shall include the having a max OD of 5 8 in. 9 / following construction features: E. Through Penetrating Products* — Max three copper conductor 9 9 PP A. Studs Wall framing may consist of either wood studs or steel No. 8 AWG . Metal—Clad Cable+ . channel studs. Wood studs to consist of nom 2 by 4 in. lumber AFC CABLE SYSTEMS INC spaced 16 in. OC. Steel studs to be min 2-1/2 in . wide and 4. Fill, Void or Cavity Material* Sealant Fill material applied within the spaced max 24 in. OC, annulus, flush with each end of the steel sleeve or wall surface. Fill B. Gypsum Board* Nom 5/8 in. thick gypsum wallboard, with square material installed symmetrically on both sides of the wall. A min 5/8 in. or tapered edges. The gypsum wallboard type, thickness, number thickness of sealant is required for the 1 or 2 hr F Rating . An of layers, fastener type and sheet orientation shall be as specified n r ooMMOOnnnnMMn Resistance Directory. Max diam of opening is 4 in. beyond surface of wall. The F Rating of the firestop system is equal to the fire rating of HILTI CONSTRUCTION CHEMICALS, DIV OF the wall assembly. HILTI INC — CP601S, CP606 or FS—One Sealant *Bearing the UL Classification Mark ( aK3MMMMnnnnMMo Reproduced b HILTI, Inc. Court of C', ❑���aRe M Y nc. Underwriters Laboratories, Inc. FIRESTOP SYSTEMS November 27, 1000 ( I IC ❑��L��a• YL �O �_ J Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. FIRESTOP SYSTEMS l V J Poge: 1 of 2 November 27, 2000 C US Page: 2 of 2 � f.1 E J L7 E J � s i R`a NN i J• Nu NC J• Nt.7 NES I ft"d*_b. FIRE ALARM SYMBOL LEGEND SYMBOL I DESCRIPTION MOUNTING HEIGHT JUNCTION BOX MODEL I QTY. X07 / STROBE LIGHT CM = CEILING MOUNT 80"-96" CEN. AFF. (OR)CEILING-SEE PLAN 4 » SQUARE SCRL 5 • FL BUILDING HORN/STROBE LIGHT CM = CEILING MOUNT 80"-96" CEN. AFF. (OR)CEILING-SEE PLAN » 4 SQUARE PC2RL 4 3 END OF LINE RESISTER ®DEVICE NON APPLICABLE 43K 1 ac FIRE ALARM CONTROL PANEL 6'-0"AFF TO TOP ENCLOSURE 5208 1 sE FIRE SIGNAL EXPANDER 6'-0"AFF TO TOP ENCLOSURE 5495 1 I -NEUTRAL 12A W� 1-NOT 12AW6 I-SROUND 12AWG TRIP FROM EXISTING SILENT KNIGHT 5208 FIRE ALARM PANEL NEW SILENT KNIGHT SK -5495 NOTIFICATION EXPANSION PANEL, 7 . UMC H k `/I 1 M 'L � Hr, .tc-2 1 r ) SCALE- NONE 00355E FIRE ALARM DESIGN INFORMATION CODES REFRENCED: • NFPA 72 [-12002 ❑ 2007 010 • NEC U 2002 [-12008 011 • NFPA 101 ❑ 2002 ❑ 2009 012 • FL BUILDING CODE 2006 ❑ 2010 5TH EDITION • FFPC 3 5TH EDITION 53' BUILDING DATA: • OCCUPANCY TYPE PRIMARY__B ____SECONDARY______ • OCCUPANT LOAD_________ • FIRE SPRINKLER SYSTEM YES ❑ NO FIRE ALARM REQUIREMENTS: • OCCUPANT NOTIFICATION YES NO • SPRINKLER MONITORING ONLY ❑ YES NO 7 NA • EMER. VOICE EVAC. ❑ YES NO FIRE ALARM SYSTEM INFORMATION: • FACP MAKE _SILENT_KNIGHT ____ • FACP MODEL 52 SK -08 _ • ❑ ADDRESSABLE CONVENTIONAL • NAC WIRE SIZE/TYPE _14=2 / FPLP_ • IDC/SLC WIRE SIZE/TYPE _18-4 / FPLP_ • MINIMUM REQUIRED BATTERY Ah • BATTERY BOX REQUIRED—YES NO • SUPERVISING STATION REMOTE [—]CENTRAL ❑ PROPRIETARY —j LOCAL • FIRE ALARM INITIATION BY: YAUTO SPRINKLER ❑ AUTO DETECTION MANUAL o�ti oRti o�ti o�ti 2�q ob3 0O� 14G/2C CLASS B 15cd 15cd 15cd 30cd 177cd 3Ocd 30cd 75cd 75cd 0.843 NAC 1 101 102 103 104 105 106 107 108 109 amps 14G/2C CLASS B NAC 2 0,000 amps 146/2C CLASS B NAC 3 0,000 s OLMPS 14G/2C CLASS B NAC 4 0.000 apps FIPE lz�\LZ\\PM PISEP D14\GP.4M SCALE : NOT TO SCALE PPP �,L�,PM PDN 8, ,�, SCALE I 1/8" = 1 ' - O" SCALE 1/8' = 1' System No. W -L-3065 (.0 System N0. W -L-3065 F Ratings - 1 and 2 Hr ( See Iters 1) o F Ratings - 1 and 2 Hr (See Iters 1) T Rating - 0 Hr _J T Rating - 0 Hr lA 2. Metallic Sleeve (Optional) — Nom 4 in. diam (or smaller) steel 30' electrical metallic tubing (EMT) or Schedule 5 (or heavier) steel pipe A2 1$ or min 0.016 in. thick (28 MSG) galv steel sleeve cast into wall 44' assembly with joint compound and installed flush with wall surfaces. 50' When Schedule 5 steel pipe or EMT is used, sleeve may extend up 50' to 18 in. beyond the wall surfaces. 3 3. Cables Aggregate cross—sectional area of cable in opening to be 53' max 45 percent of the cross—sectional area of the opening. The 55' annular space between the cable bundle and the periphery of the 55' opening to be min 1/4 in. to max 3/4 in. Cables to be ridigly 59' supported on both sides of the wall assembly. Any combination of the 4 following types and sizes of copper conductor cables may be used: A A. Max 7/C No. 12 AWG with polyvinyl chloride (PVC) insulation and 63' jacket. 68' B. Max 25 pair No. 24 AWG telephone cable with PVC insulation and SECTION A—A jacket. 1. Wall Assembly The 1 or 2 fire—rated gypsum wallboard/stud wall C. Type RG 59/U coaxial cable with polyethylene (PE) insulation and assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition PVC jacket. D. Multiple fiber optical communication cable jacketed with PVC and Designs in the g e UL Fire Resistance Directory and shall include the having a max OD of 5 8 in. 9 / following construction features: E. Through Penetrating Products* — Max three copper conductor 9 9 PP A. Studs Wall framing may consist of either wood studs or steel No. 8 AWG . Metal—Clad Cable+ . channel studs. Wood studs to consist of nom 2 by 4 in. lumber AFC CABLE SYSTEMS INC spaced 16 in. OC. Steel studs to be min 2-1/2 in . wide and 4. Fill, Void or Cavity Material* Sealant Fill material applied within the spaced max 24 in. OC, annulus, flush with each end of the steel sleeve or wall surface. Fill B. Gypsum Board* Nom 5/8 in. thick gypsum wallboard, with square material installed symmetrically on both sides of the wall. A min 5/8 in. or tapered edges. The gypsum wallboard type, thickness, number thickness of sealant is required for the 1 or 2 hr F Rating . An of layers, fastener type and sheet orientation shall be as specified additional 1/2 in. diam bead of fill material shall be applied around in the individual U300 or U400 Series Designs in the UL Fire the perimeter of sleeve on both sides of the wall when sleeve extends Resistance Directory. Max diam of opening is 4 in. beyond surface of wall. The F Rating of the firestop system is equal to the fire rating of HILTI CONSTRUCTION CHEMICALS, DIV OF the wall assembly. HILTI INC — CP601S, CP606 or FS—One Sealant *Bearing the UL Classification Mark pSs1F��O Reproduced b HILTI, Inc. Court of C', ❑���aRe M Y nc. Underwriters Laboratories, Inc. FIRESTOP SYSTEMS November 27, 1000 ( I IC ❑��L��a• YL �O �_ J Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. FIRESTOP SYSTEMS l V J Poge: 1 of 2 November 27, 2000 C US Page: 2 of 2 SYSTEM DESIGN REQUIREMENTS h;�:, go -w ed B • • EXISTING SYSTEM IS POWER LIMITED ..i ��� • EXISTING PANEL HAS BATTERY BACKUP 24HP STANDBY / Ji MINUTES ALARM. • SYSTEM IS CURRENTLY BEING MONITORED. • NAC CIRCUITS ARE CLASS "B". f^ r ire D7t. • IDC CIRCUITS ARE CLASS "B". %,_ • FACP/PWR SUPPLIES HAVE A DEDICATED 120VAC CIRCUIT AN[ .14e: / COMPLY WITH THE REQUIREMENTS OF NFPA 72, 2010 ED SECTION 10.5.5.1. • RE -ACCEPTANCE TESTING OF THE FIRE ALARM SYSTEM SHAL BE PER NFPA 72, 2010 EDITION SECTION 14,412. • ALARMS SHALL BE 15 DECIBELS ABOVE AMBIENT SOUND BUT NOT MORE THAN 110 DECIBELS TOTAL AT THE DEVICE. CANDELA SPACING CEILING MOUNTED DEVICES 10' 15cd 20' x 20' 30cd 30' x 30' 75cd 44 x 44' 95cd 50' x 50' 110ed 53' x 53' 115cd 55' x 55' 135cd 59' x 59' 150cd 63' x 63' 177ed 68' x 68' 185cd 70' x 70' RISER AND FACP SCALE : NOT TO, SCALE "OV X12017 AREA OF WORK �►-0 i 4' i L ° FIRE ALARM 1 SYSTEM a DIVISION OFFICE COPY PER NFPA 72 14.2.2.1 THE OWNER OR THE OWNER'S DESIGNATED REPRESENTATIVE SHALL RESPONSIBLE FOR INSPECTION, TESTING, AND MAINTENANCE OF THE SYSTEM AND GRAPHICS ELEMENTS N-0TIE FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, STRUCTURAL, OR MEP DRAWINGS, THESE REFERENCE BACKGROUND ELEMENTS ARE FOR GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER ENGINEER P E i$ ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER DRavINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED ARCHITECTURAL, STRUCTURAL, NEP OR CIVIL 2010 ED., NEC 2011 ED., AND NFPA 101 2012 ED. SYSTEM INFORMATION MANUFACTURER SILENT KNIGHT SILENT KNIGHT -- MODEL # 5208 5495 -- # OF ALARM ZONES -- -- -- # OF SIGNAL CIRCUITS -- 1 -- DATE I SUBMITTALS XX/XX/XX -- INDICATING AP SYMBOL MODEL QTY COMMENTS NOES INITIATING DEVICES SYMBOL QTY TYPE ZONE TEMP MODEL -- TOTAL THIS SHEET DRAWINGS OR DETAILS WAYNE •I COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND VILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE INFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANT SUCH PERMISSIONS. MAIN OFFICE — ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE. FLORIDA 34781 s 0. DATE REVISIONS BY 3225 CHERRY PALM DRIVE TAMPA FL 3.'3619-8337 A XX/XX/XX -- - FT. MYEF46 F:L CDP[:om Nc STATE UCENSE.S: 4683 LAREDO AVE FT. MYERS, FL 33905-4924 4370 MOTORSPORT DRIVE CONCORD. M 26027-8977 FL ALARM. EF20001320 M ALARM: 29222 SP LW PHONE (239) 433--3030 PHONE: (704) 782-3032 SC ALARM: 33815 FAX: (239) 433-3253 FAX: (704) 796-6638 GA ALAN. LV.4205682 -MSKP GATEWAY, LLC 101 TOWN CENTER BLVD., STE. 211 SANFORD, FL SYSTEM NOTES OF WORK: FOR NEW TENANT RENOVATIONS, ADD NEW NOTIFICATION EXPANDER AND CONNECT TO EXISTING FIRE ALARM SYSTEM, ffAtSCOPE C nCQTGUCn nun TAIPTAI I Un Tu Arrnr)nA\Irr 1r7T11 carne 11 2010 ED., NEC 2011 ED., AND NFPA 101 2012 ED. SYSTEM INFORMATION MANUFACTURER SILENT KNIGHT SILENT KNIGHT -- MODEL # 5208 5495 -- # OF ALARM ZONES -- -- -- # OF SIGNAL CIRCUITS -- 1 -- DATE I SUBMITTALS XX/XX/XX -- INDICATING AP SYMBOL MODEL QTY COMMENTS NOES INITIATING DEVICES SYMBOL QTY TYPE ZONE TEMP MODEL -- TOTAL THIS SHEET 995 N. SR 434 STE. 2720 • ()ALTAMONTE SPRINGS, FL 32714 (SHEET TITLE, FIRE ALARM DRAWN BY: BRANDON LOPP SCALE, 1/8" = 1' DATE, 10-9-17 AHJ, CITY OF SANFORD CONTRACT # 87682 7882 SHEET # FA1 YEAR EDITION OF NFPA 7a 2010 OCCUPANCY, B WAYNE it Automatic Fire Sprinklers, Inc. MAIN OFFICE — ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE. FLORIDA 34781 PHONE: (407) BW -3030 FAX (407) 858-8028 JACFC80NVL.LE, FL TAMPA, F I PawAm nEAm Fl 11326 MTT49UTION AVE. WEST JACKsnNVILLE. FL 32256-2745 3225 CHERRY PALM DRIVE TAMPA FL 3.'3619-8337 3121 NW 16TH TERRACE POMPANO BEACH. FL 33084-1408 PHONE (904)2156-3030 FAX. (904) 268-0724 PHONE (813) 630-0303 FAX: (613) 630-032 PHONE (954) 97-3030 FAX: (964) 917-9424 FT. MYEF46 F:L CDP[:om Nc STATE UCENSE.S: 4683 LAREDO AVE FT. MYERS, FL 33905-4924 4370 MOTORSPORT DRIVE CONCORD. M 26027-8977 FL ALARM. EF20001320 M ALARM: 29222 SP LW PHONE (239) 433--3030 PHONE: (704) 782-3032 SC ALARM: 33815 FAX: (239) 433-3253 FAX: (704) 796-6638 GA ALAN. LV.4205682 -MSKP GATEWAY, LLC 101 TOWN CENTER BLVD., STE. 211 SANFORD, FL de MSKP GATEWAY, LLC 995 N. SR 434 STE. 2720 • ()ALTAMONTE SPRINGS, FL 32714 (SHEET TITLE, FIRE ALARM DRAWN BY: BRANDON LOPP SCALE, 1/8" = 1' DATE, 10-9-17 AHJ, CITY OF SANFORD CONTRACT # 87682 7882 SHEET # FA1 YEAR EDITION OF NFPA 7a 2010 OCCUPANCY, B