Loading...
HomeMy WebLinkAbout512 Red Rose Ln 18-667 (roof/truss)COUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 18100001 BUILDING APPLICATION #: 18-10000136 BUILDING PERMIT NUMBER: 18-10000136 DATE: February 20, 2018 � � 1 6�9 vj UNIT ADDRESS: RED ROSE LANE 512 21-19-30-510-0000-1650 TRAFFIC ZONE:022 JURISDICTION: a SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: TAYLOR MORRISON OF FL INC ADDRESS: 2600 LAKE LUCIEN DRIVE SUITE 350 MAITLAND FL 32751 LAND USE: SINGLE FAMILY RESIDENCE TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 512 RED ROSE LANE / THORNBROOKE PHASE 4 / SFR -----------------------•-----•--- ------••-------------------------------------- FEE BENEFIT RATE UNIT CALL UNIT TOTAL DUE TYPE DIST SCHED RATE UNITS TYPE -----------------•----- ---------------•--------------- ROADS-ARTERIALS CO -WIDE ORD Single Family Housing 705.00 1.000 dwl unit 705.00 ROADS -COLLECTORS N/A Single Family Housing .00 1.000 dwl unit .00 FIRE RESCUE N/A 00 LIBRARY CO -WIDE ORD Single Family SCHOOLS Housin 54.00 1.000 dwl unit 54.00 gle Family CO-WYDE ORD Housing 51000.00 1.000 dwl unit 5,000.00 PAST LAW ENFORCE N/A .00 DRAINAGE N/A 00 .00 AMOUNT DUE 5,759.00 PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE DATE ABOVE, BUT NO LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES 8OVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE BUSINESS OFFICE: 1101 EAST FIRS`i' STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREETOP SANFORD, FL 32771 /(�� PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE 1` THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT ISSUED WITHIN 60 CALENDAR DAYS FROM THE DATE ABOVE 1 i'—R" q'—¢, NOTE: DO NOT CUT OR ALTER TRUSSES WITHOUT CONSENT OF THIS OFFICE. BACK CHARGES WILL NOT BE ACCEPTED WITHOUT PRIOR WRITTEN APPROVAL BY OUR SERVICE DEPARTMENT AT CARPENTER CONTRACTORS OF AMERICA, INC. 877-293-9487 15_8» 14'-4" THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND F[,1.10 MIJV) HI-[. v DAcr 7 a� 71 M%� P\, CHfT fLF F11"Oor AL- HUS 26 ( S I MPSON) J L= THA 422 ( S I MPSON) ARCHITECTURALS SUPERCEDE THIS DOCUMENT RECORD COPY TYPIC -Al, 7 5FTA(-K r� COP -T5�1 ANP 5PACIN6 w- J��olrr� OE- PPV - Labeled End Mark ATTENTION I IT DON'T LIFT SINGLE TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK CONSULT BCSI -DI 30'Span r less 30' to 60' Span Spread r Bar 60 degrees or less Una [11/2 2/3 /2 rl p� Ti IIJ spantor1ox. REFER TO BCSI —B1 Truss Aust be set this way if crane used, f runs is an exampte, your truss may not match, Insist crane operator, sets truss this way, Total Truss Quantity = 189, General Notes 1) All parallel chord trusses, flat trusses and flat girders have the top chord partially painted green to be installed green side up. 2) All hungers to be Simpson 11126 unless otherwise noted. 3) All truss spacing is 24" U.C. unless otherwise noted. 4) Per Truss Plate Institute SCSI -131 recornrnendation permanent X—bracing should be placed at a rnaximurn spacing 15' U.C. across the span, to be repeated at a maxirnurn of 20' between each X—brace throughout the structure. Please refer to BCSI-131 for any additional bracing details. ROOF LOADING SCHEDULE TCLL = 20 PSF TCDL - 17 PSF BCLL = * PSF BCDL = 10 PSF TOTAL - 47 PSF DURATION - 1.25 WIND SPD/TYPE = 150 MPH ENCLOSED BLDG EXPOSURE = C USAGE = RESIDENTIAL CAT II WIND IMPORTANCE FACTOR = 1 UPLIFTS BASED ON = 9.2 PSF DESIGN CRITERIA FB C 2017 TPI 2014 Truss member design &- connector plates are designed for ASCE 7--10 and maximum forces from both components and claddings and plain wind force resisting systems. * These trusses have been reviewed to carry an additional 109 pst non -concurrent bottom chord live load. FLOOR LOADING SCHEDULE TCLL = 40 PSF TCDL = 10 PSF BCDL = 5 PSF TOTAL = 55 PSF ALL REACTIONS OVER 5000# AND UPLIFTS OVER 1000# ARE SHOWN ON ENGINEERING, WALL KEY 20' -5/ 4I T .� LOAD# DESCRIPTION INF. DATE R/01 New Model rdg 8/24/11 R/01 Cutting rdg 12/15/11 R/01 NEW WIND AND LUMBER JRH 04-10-12 RAO! RERAN R NEW WIND 140C JRH 05/09/2012 RBO1 C3 HMT 07/12/13 R/01 IL COPY RE3 2585A/REV'D PFH 10.03,2016 RA01 COPY JOB, RELABEL RDP 2/20/17 RA01 LC9 HMT 12/15/17 LOAD# DESCRIPTION INIT. DATE r CONTRAC, I ORK OF' A.MERIC.A. 3900 AVENUE G, N. W, WINTER HAVEN FLORIDA 33880 PI-ICINEI ( 800) 959-8806 FAX: ( 863) 294-2488 BUILDER TAYLOR MORRISON PROJECT `I'HORNBROOK MODEL 2582/A CCA PROD/MODEL/ALT 9A6/9A7/258SE ALT DESC: OTC : LOT: 165 BLOCK ??? 11/18/02 9:52 AM UCA40.dwg CARPENTER I F, r CONTRAC, I ORK OF' A.MERIC.A. 3900 AVENUE G, N. W, WINTER HAVEN FLORIDA 33880 PI-ICINEI ( 800) 959-8806 FAX: ( 863) 294-2488 BUILDER TAYLOR MORRISON PROJECT `I'HORNBROOK MODEL 2582/A CCA PROD/MODEL/ALT 9A6/9A7/258SE ALT DESC: OTC : LOT: 165 BLOCK ??? 11/18/02 9:52 AM UCA40.dwg