Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2301 W Lake Mary Blvd 18-4442- INTERIOR REMODEL
r s eaitu�CITY OF Sk�40RD .BUILDING DIVISION PERMIT APPLICATION Application No:t- � � 91), Documented Construction Value: $ 9,61000 Job Address: 3)tyc" �4yr- (Vic ,/ ,?&L -,e -OCA Historic District: Yes❑ No[] Parcel ID: i���O©�O Residential ❑ Commercial Type of Work: New ❑ Addition ❑ Alteration Repair ❑ I Deino❑ Change of Use [IMove❑ Description of Work: orli'Vnc, t ,, "Vs- �r- neA ts i ee. s, c:�s /'eine Ilia ^f --v —z---- —� !� i t pt,,c iS (✓l o t/e '� cAJ S'Im4,, , . Alt nz,-w reC e p kac k3 . n E9 Plan Review Contact Person: C� �s ��17jeC er Title: Phone: �38b-33�(-�oz� Fax: 3?7b--La9-83-L06 Email: CWlsc�s%�..rtzt- Property Owner Information Name /�/�ell`lf�L �[ G l � Phone: 16-7 Street: l4 Resident of property?: City, State zip: j j Contractor Information Nance l� 7rAS'1a1Jk 1A I Phone: Street:6 l U /1; �/ (��C Fax. City, State Zip: Cde#e(--Pce, c ``' State License No.: Arch ei -t -ect/Engineer Information Nance: JJICrn �dl S%� P �G� ���cf -1- c Phone: & 07 - 331 Street: .')(.PO laVt v F�� � CSV-c�Fax: / City, St, zip: //)L1 f'I �y�t) , >�' `) 2 TS J E-mail: All Bonding Company: Address: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMrtitENCEMENT MAY RESULTIN YOUR PAYING TWICE FOR IMPROVEMEN'T'S TO YOUR PROPER'L'Y. A NOTICE OF COMMENCEMENT MUSTBE RECORDED AND POSTED ON T'HE JOB SITE BEFORE THE FIRSTINSPECITON. IF YOU IN'T'END '1'O OB'I'AIN FINANCING, CONSULT' WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NO'T'ICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and iustallalions as indicated. I certify that no work or iustaltatiou has commenced prior to the issuance of a permit and that all work will be performed to meet standards of alt laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. rI '� �� � � � � � Lj . L-A M ria y • %00/ TE T lmrROVMEN fol 23 V4 1 hast Lake ila_ 07 "oulevald F Sanfoi- Florida A PERMIT jl' :)(JED SHALL BE CONSTRUED To BE A IJCEPJ3L; r(7 IaROCEE D WITH THE WORI< AND NOT AS AUT HORPY TO VIOLATE, c,ANCFL, ALTER OR SET ;;;IDI ANY OF TNI PROVISIONS OF THE TECHNICAL SHALL ISSUANCE OF A PEWArl' PREVENT THE. ntJ;LDING OFFICIAL FROM THEREAFTER A CORRECTION OF ERRORS IN PU''1NS. 'TION OR VIOLJVFIONS OF THIS COD'r. LOCATION MAP SH�E�I' INDEX t aa�f��lu��',& z` NUMBER SHEET TITLE PERMIT ISSUE REVISED REVISED y z i 115 i' ISSUE 1 i 1- i r � � x SET INDEX 11-OS-18 COVER ARCHITECTURAL ' u n r .d: 1;; �t r 6 � d S� I �` ��' I •'' t I� A .101 1 r 1 1fEtl�i�,�F�k> Ez5w5F r6 LiFE SAFETY PLAN 11-OS-18 r _ ,,, , } A 102 FLOOR PLANS 11-05-18 No ven_b� 5 201uzw �.: ,a+ �tSt 4 1 �r r 1 1 ui t 1 o i x d I .� I '1.1 9 8 PROJECT � °�;� A.103 U.LIAILS 11-05-18 y Olt8F1 t 8 f A MECHANICAL M-001SYMBOL LEGEND - MECHANICAL 11-05-18 -2U1 - MECHANICAL -05-18 M L �z�ala i �` �trNd r. , , . '4 >�'Y�� rf 0$ , � r �� � � -. r: z .d� ' 'a M• �' I t' i } �. FLOOR PLAN lt 1� 4��ej�6,f PLUMBING na �2 �y,} _ q•T � 1 f e : y 9 � � �,� 1 ' � ""i1�� � 4 � � �' 'fir 14 i, r ,•'���,'�7.�4 f I ELECTRICAL r _ l 1i`�c�� 1'�, ' ,,. OWNER FATHERS TABLE�,z��.�,1�_ � _ ELECTRICAL � ���� E 001 SYMBOL LEGEND ELECTRICAL 11-05.18 J� 2301 East Lake Mary Boulevard ,,, E-201 FLOOR PLAN -ELECTRICAL 11-05-18 Sanford, Florida 32773 E-301 SCHEDULES -ELECTRICAL 11-05-18 N E-401 DETAILS - ELECTRICAL 11-05-18 ARCHITECT BLAN.KENSHIP ARCHITECTS INCORPORTATED NOwrit _ 540 Lake Faith Circle NO SCALE E-501 SPECIFICATIONS - ELECTRICAL 11-05-18 Maitland, Florida 32751 Phone 407.331.8868 , nelsori@blanlcenshiparchitects.com JOSEPH LAWRENCE & CO LLC GENERAL 1 v �T O T S � MECHANICAL 138 WEST JESSUP AVENUE ELECI'.RICAL & LONGWOOD, FL 32750 PLUMBING 32.1.72.4466 c 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE BUILDING CODES, SPECIFIC BUILDING RESTRICTIONS AND INDUSTRY CONSTRUCTION 1NGENGINEER CONTACT: ADAM BARNEY STANDARDS AND SPECIFICATIONS. 407.454.1911 CELL 2. FOR THESE DOCUMENTS, THE TERMS 'O WNER' AND 'TENANT' ARE INTERCHANGEABLE. GENERAL CON'T'RAC'T'OR CW CONSTRUCTION 3. GENERAL CONTRACTOR IS TO MAINTAIN LIFE SAFETY AND .EtvtERGENCY EGRESS .E� UNCT.IONALITY DURING CONSTRUCTION. GC SHALL 2610 Unity Tree PROVIDE CONSTRUCTION BARRIERS AS REQUIRED AND COORDINATE WITH TENANT. Edgewater, Florida 32141 Phone 386.235.0986 4. DIMENSIONS AND CONDITIONS INDICATED IN THESE DRAWINGS ARE BASED ON DOCUMENTS AND INFORMATION PROVIDED. GC SHALL Contact: Andrew Gentry VERIFY EXISTING ACTUAL CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT / TENANT OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIALS AND COMMENCEMENT OF WORK. 5. PROTECT ALL EXISTING MATERIALS AND FURNISI-ZINGS DESIGNED TO .REMAIN. DAMAGED ITEMS SHALL BE REPLACED COMPLETELY BY T AAT�E�T s�fo LAKE FArD, L 327CIRC1 THE GENERAL CONTRACTOR TO THE ITEM'S CONDITION A'I' COMMENCEMENT OF THE PROJECT. CONSTRUCTION PERFORMED ADJACENT TO .JLC lel lr MAITLAND, FL 32751 PH. 407.331.8868 EXISTING MATERIALS SHALL BLEND IN TEXTURE, FINISH AND COLOR WHEN FINISHED SO AS TO NOT BE DETECTABLE. 84 ARCHITECTS FX. 4A 260 .1666 Registration AA 26001666 6 IF POWER MUST BE CUT OFF TEMPORARILY, NOTIFY THE TENANT 24 HOURS MINIMUM :IN ADVANCE OF THE SCHEDULED CU I, OFF TIME. ® � TE� nelson cr Copyright p yritects.c 0) copyright � 7. DURING CONSTRUCTION, GENERAL CONTRACTOR SHALL PARK VEHICLES AND .EQUIPMENT, ETC. INA LOCATION APPROVED .BY TENANT. 8. DIMENSIONS SHOWN ARE TO FACIE OF CONCRETE, CONCRETE MASONRY UNITS (CMU) OR FACE OF STUDS UNLESS NOTED OTHERWISE (UNO). .1� THI5 PROJECT IS THE MODIFICATION OF AN EXISTING OPEN OFFICE AREA AND OFFICES INTO OFFICESLLER INDIVIDUAL ROOM. OF GWB PROJECT D OX15TINGGCI GRI CABOARD WALLS WITH METAL STUDS, EX15T1 RPETT REPAIRED, (LING AND515T5 TILE MAIN WITH ADJUSTED LIGHTS AND DIFFUSERS, THE TOTAL OFFICE AREA 15 6,091 5F. THE AREA DESCRIPTION OF THI5 PROJECT 15 1,281 5F. CODE ANALYSIS CODES IN EFFECT FLORIDA BUILDING CODES, 6 TH EDITION FLORIDA FIRE PREVENTION CODE, 6TH EDITION NATIONAL ELECTRIC CODE 2014 Applicable State, Federal and Local Godes and Regulations SUBJFzCT REFEFENCE — AFFLICATION fi FOUIDEU OCCUPANCY SECTION 304.1 - OFFICES - BUBINE55 421 CONSTRUCTION TYPE TABLE 601 - TYPE v B TYPE V B SPRINKLED AUTOMATIC SPRINKLER REQUIRED - PROVIDED FULLY SPRINKLED PROJECT 1, 281 5F ALLOWABLE BUILDING AREA MAX BU51NE55 - 23,000 SF PER FLOOR (per floor) BUSINESS B SPRINKLED - 23,000 X 3 = 96,000 SF Lz CLASSIFICATION SEPARATION SECTION 1083 - TENANT SEPARATIONS NOT APPLICABLE HEIGHT MAX TABLE 503 - 55 FT 30 FT EXISTING EXITS REQUIRED SECTION 1015.1 - 1 - 500 = 2 FIRST FL -2 EXIT TRAVEL MAX TABLE 1016.2 - BU51NESS - 300 FT (5PRK) 85 FT CORRIDOR DEAD END LIMIT SECTION 1018.4, EXCPT 2 50 FT NONE FIRE RESISTANCE RATINGS BUILDING ELEMENTS PRIMARY STRUCTURAL FRAME TABLE 601 - 0 HR 0 HR BEARING WALLS EXTERIOR > 30 FT TABLE 602 - 0 HR 0 HR NON BEARING WALLS EXTERIOR TABLE 601 - 0 HR 0 HR NON BEARING WALLS INTERIOR TABLE 601 - 0 HR 0 HR FLOOR CONSTRUCTION TABLE 601 - 0 HR 0 HR ROOF CONSTRUCTION TABLE 601 - 0 HR 0 HR EGRE55 (occupant load) TABLE 1004.1-2 - EGRE55 REQUIREMENTS FIRST FLOOR 6,091 SF / 100 PER 6l PEOPLE TOTAL OFFICE PERSONS = 61 CALCULATION OF EXIT DOOR WIDTHS FIRST FLOOR 61 X.15 92' REAUIRED FOR OFFICES 2 SINGLE DR5, 2 X 32' = 64' PLUMBING FIXTURE REQUIREMENTS TABLE 403.1 - FLORIDA PLUMBING CODE BUSINESS 1 / 25 for first 50 WATER CLOSETS NOT AFFECTED 1/ 50 rema lnder LAVATORIES BU51NE55 I / 40 for first 80 I / 80 remainder NOT AFFECTED DRINKING FOUNTAINS BUSINESS 1/ 100 NOT AFFECTED 5ERVIGE SINK BUSINESS 1 NOT AFFECTED 00 SITE ENLARGEMENT PLAN SCALE: NONE; OVERALL BUILDING PLAN SCALE: 1/32"=1'4' n- low TOTAL OFFICE AREA ICE mr-11il•I PROJECT OFFICE AREA OFFICE 103 PROJECT LIFE SAFETY 0 z SCALE: 1/8"=1'-O" PLAN SYMBOL LEGEND FE E FIRE EXTINGUISHER BRACKET MOUNTED ON WALL (4-A:60:15:0, 10 LB TYPE)- TOP OF EXTINGUISHER 50' AFF. EXTINGUISHERS IN KITCHENS ARE CLA55 'K'. FEC FIRE EXTINGUISHER IN RECESSED CABINET. O (4-A:(b0:5:C, 10 LB TYPE) CENTER OF z CA51BET AT 42' AFF. 164 EXIT DISCHARGE POINT AND NUMBER OF OCCUPANTS SERVED 60 FT TRAVEL — — — — EXIT PATHS AND TRAVEL DISTANCES EQUIPMENT 138 ROOM NAME d NUMBER This item has b 6lectronicall y signed and sea le y Nelson Blankenship, Jr. on using a digital signature. Printed copies of this document are not considered signed and scaled and the signature must be verified on any electronic copies. tov-Q L VVViii �B 18 : t; ; ,,., acnQa LLI E , U rt NBB U v O 1 z W y t'`J J a 421 O w r _ Zx� Lz �U0� <�, cri c w W (Z) DRAWN CHECKED NBB NBB U 7� �� 1 DRAWING NUMBER y t'`J 421 cri c w W (Z) DRAWN CHECKED NBB NBB PROJECT NUMBER 1822 DRAWING NUMBER A-1011 DATE 11-5-18 CD O Q.. L U N 0 electrouicully This iteur has b01[9/1.8 signed and 131aulceuship, Jr. ou using a digital siguaturv. Priuled copies of this docuu3eut are not considered signed and seated Wld thQ) Signature IllllSt b4 verified oil lu3y electronic copies. t1 J elson la c ISfil 1A v C!1 u in o `! a ~ 3 o U f r q 7 u P4 u CA N O A d 1 cn C`t CO() C) 0 F� DRAWN CHECKED PROJECT NUMBER 1822 DRAWING NUMBER A-102 DATE 1 1-5-18 SIZE A5 SIZE A5 SCHED �'� 5� 5/8' GYP BD ON 2X4 WOOD STUDS a 24' OC (TYP) p p u.t w p pLu Lu SEALANT CONT EA SIDE (TYP) C � thus DOOR 4 FRAME A AS SCHEDULED DOOR & FRAME TYPES Hi SCALE: 3/16"=1'-0" �— 5/8' GYP BD ON 2X4 WOOD STUDS m 24' OC (TYP) SEALANT CONT EA SIDE (TYP) -= DOOR 4 FRAME AS SCHEDULED -- - --- .j J1 DOOR DETAILS SCALE: 1 1/2"=-1'-0" �-- BAR JOISTS r o B LA 2x4 STUD CONT ANCHOR TO JOIST W/ (2) 1/2' POWER ACTUATED PINS OR EQUAL BRACE WALL TO STRUCTURAL MEMBERS ABOVE W/ 2x4 STUDS a 48' OC EXISTING CEILING GRID AND TILE TO / REMAIN PATCH A5 REQUIRED WITH �rrr MATCHING GRID AND TILE EXISTING SUSPENDED ACOUSTICAL CEILING GRID WITH NEW TILE AS SCHEDULED /8' GYP BD ON EA 51DE OF 2x4 STUDS 24 OG, VI/2'NAIL5 ANCHORED AT EA END WITH TWO 16d COATED, 3 OR 3" DECK SCREWS (TYP) FLOOR FINISH AND BASE { SEE FINISH SCHEDULE POWER ACTUATED FA5TENTER (HILTI .13a OR EQ) 2 1/2" LONG 1w 24' OC (TYP) , N ON I� - T.ED - GYP D' WALL -TYPICAL ACT CEILING SCALE: l 1/2" = l'-0" Doo.R SCHEDULE DOOR :DOOR �IfZD W F 1Z.AME F1.1ZE DETAILS NO. SIZE MAT. FINISH TYPE SET' :MAT. FINISH. :TYPE RATING HEAD JAMB SILL NOTES 101 3'-0' x 8'-8' EXIST EXIST A EXIST WOOD STAIN 1 N/A NI JI -- DOOR IS RELOCATED 102 3'-0' x 6'-8' SC WOOD STAIN A MATCH WOOD STAIN 1 N/A NI JI -- UNDERCUT I' 103 3'-0' x 6'-8' SC WOOD STAIN A MATCH WOOD STAIN 1 N/A HI JI -- UNDERCUT I' 104 3'-0' x �'-a' SG WOOD STAIN A MATCH WOOD STAIN I N/A Hl JI -- UNDERCUT I" 105 3'-0° x 6'-8' SC WOOD STAIN A MATCH WOOD STAIN I N/A NI JI -- UNDERCUT I' 106 3'-0' x 6'-8' SG WOOD SLAIN A MATCH WOOD STAIN I N/A Hl JI -- UNDERCUT I' 101 3'-0' x 6'-8' SG WOOD STAIN A MATCH WOOD STAIN I N/A Nl JI -- UNDERCUT I' DOOR SCEIEDULE GENERAL NU:I'ES I. EXCEPT AS SPECIFICALLY PERMITTED BY SECTION 1008.1.8, 5. HARDWARE TO BE COORDINATED WITH THE OWNER AND EGRESS DOORS SHALL BE READILY OPENABLE FROM THE LANDLORD EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 2. DOORS DESIGNATED AS EXITS MAY REQUIRE PANIC DEVICES, SEE SCHEDULE AND COMPLY WITH APPLICABLE COPES. 3. HARDWARE OPERATION SHALL BE PER OWNER'S REQUIREMENTS AND COMPLY WITH FBG AND NFPA IOL 4. NEW HARDWARE SHALL BE LEPER TYPE HANDLES, ADA COMPLIANT m 0 U N D a� 0 This iteut has been electronically signed and sealer���tSy Nelson Blatilcenship, r. on ..���f�fj�j� 9/18 using a digital siguahuc. Printed copies of this docutnent are not considered signed and sealed utxt the slgnahire must be verified ou any electronic copies. l gyp i(A U / U T r --i ti o U � 11��'99 'r 1 r� 1A W �1 DRAWN CHECKED PROJECT NUMBER 1822 DRAWING NUMBER A-103 DATE 11-5-18 SIZE A5 SIZE A5 SCHED �'� 5� 5/8' GYP BD ON 2X4 WOOD STUDS a 24' OC (TYP) p p u.t w p pLu Lu SEALANT CONT EA SIDE (TYP) C � thus DOOR 4 FRAME A AS SCHEDULED DOOR & FRAME TYPES Hi SCALE: 3/16"=1'-0" �— 5/8' GYP BD ON 2X4 WOOD STUDS m 24' OC (TYP) SEALANT CONT EA SIDE (TYP) -= DOOR 4 FRAME AS SCHEDULED -- - --- .j J1 DOOR DETAILS SCALE: 1 1/2"=-1'-0" �-- BAR JOISTS r o B LA 2x4 STUD CONT ANCHOR TO JOIST W/ (2) 1/2' POWER ACTUATED PINS OR EQUAL BRACE WALL TO STRUCTURAL MEMBERS ABOVE W/ 2x4 STUDS a 48' OC EXISTING CEILING GRID AND TILE TO / REMAIN PATCH A5 REQUIRED WITH �rrr MATCHING GRID AND TILE EXISTING SUSPENDED ACOUSTICAL CEILING GRID WITH NEW TILE AS SCHEDULED /8' GYP BD ON EA 51DE OF 2x4 STUDS 24 OG, VI/2'NAIL5 ANCHORED AT EA END WITH TWO 16d COATED, 3 OR 3" DECK SCREWS (TYP) FLOOR FINISH AND BASE { SEE FINISH SCHEDULE POWER ACTUATED FA5TENTER (HILTI .13a OR EQ) 2 1/2" LONG 1w 24' OC (TYP) , N ON I� - T.ED - GYP D' WALL -TYPICAL ACT CEILING SCALE: l 1/2" = l'-0" Doo.R SCHEDULE DOOR :DOOR �IfZD W F 1Z.AME F1.1ZE DETAILS NO. SIZE MAT. FINISH TYPE SET' :MAT. FINISH. :TYPE RATING HEAD JAMB SILL NOTES 101 3'-0' x 8'-8' EXIST EXIST A EXIST WOOD STAIN 1 N/A NI JI -- DOOR IS RELOCATED 102 3'-0' x 6'-8' SC WOOD STAIN A MATCH WOOD STAIN 1 N/A NI JI -- UNDERCUT I' 103 3'-0' x 6'-8' SC WOOD STAIN A MATCH WOOD STAIN 1 N/A HI JI -- UNDERCUT I' 104 3'-0' x �'-a' SG WOOD STAIN A MATCH WOOD STAIN I N/A Hl JI -- UNDERCUT I" 105 3'-0° x 6'-8' SC WOOD STAIN A MATCH WOOD STAIN I N/A NI JI -- UNDERCUT I' 106 3'-0' x 6'-8' SG WOOD SLAIN A MATCH WOOD STAIN I N/A Hl JI -- UNDERCUT I' 101 3'-0' x 6'-8' SG WOOD STAIN A MATCH WOOD STAIN I N/A Nl JI -- UNDERCUT I' DOOR SCEIEDULE GENERAL NU:I'ES I. EXCEPT AS SPECIFICALLY PERMITTED BY SECTION 1008.1.8, 5. HARDWARE TO BE COORDINATED WITH THE OWNER AND EGRESS DOORS SHALL BE READILY OPENABLE FROM THE LANDLORD EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 2. DOORS DESIGNATED AS EXITS MAY REQUIRE PANIC DEVICES, SEE SCHEDULE AND COMPLY WITH APPLICABLE COPES. 3. HARDWARE OPERATION SHALL BE PER OWNER'S REQUIREMENTS AND COMPLY WITH FBG AND NFPA IOL 4. NEW HARDWARE SHALL BE LEPER TYPE HANDLES, ADA COMPLIANT m 0 U N D a� 0 This iteut has been electronically signed and sealer���tSy Nelson Blatilcenship, r. on ..���f�fj�j� 9/18 using a digital siguahuc. Printed copies of this docutnent are not considered signed and sealed utxt the slgnahire must be verified ou any electronic copies. l gyp i(A U / U T r --i ti o U � 11��'99 'r 1 r� 1A W �1 DRAWN CHECKED PROJECT NUMBER 1822 DRAWING NUMBER A-103 ABV ABOVE ADJ ADJUSTABLE AF AIRFOIL AFF ABOVE FINISHED FLOOR AC AIR CONDITIONER ACU AIR CONDITIONING UNIT AHU AIR HANDLING UNIT AP ACCESS PANEL BAS BUILDING AUTOMATION SYSTEM BI BACKWARD INCLINE BLDG BUILDING BHP BRAKE HORSEPOWER BTUH BRITISH THERMAL UNIT PER HOUR BDD BACKDRAFT DAMPER CD CONDENSATE DRAIN CFM CUBIC FEET PER MINUTE CLG CEILING CW CHILLED WATER CWR CHILLED WATER RETURN CWS CHILLED WATER SUPPLY CONC CONCRETE COND CONDENSATE CONT CONTINUOUS CO CARBON MONOXIDE COP COEFFICIENT OF PERFORMANCE CU CONDENSING UNIT DB DRYBULB DWDI DOUBLE WIDTH, DOUBLE INLET DWGS DRAWINGS DX DIRECT EXPANSION EF EXHAUST FAN EXH EXHAUST EA EACH EAT ENTERING AIR TEMPERATURE EER ENERGY EFFICIENCY RATIO ELECT ELECTRICAL ENT ENTERING EQ EQUAL ER EXHAUST REGISTER EWT ENTERING WATER TEMPERATURE FC FORWARD CURVED FCU FAN COIL UNIT FD FIRE DAMPER FL FLOOR FLEX FLEXIBLE CONNECTOR OR DUCT FPM FEET PER MINUTE F/S COMBINATION FIRE AND SMOKE DAMPER FT. H2O FEET WATER GAUGE F DEGREES FAHRENHEIT GA GAUGE GAL GALLON GALV GALVANIZED GPM GALLONS PER MINUTE HP HORSEPOWER HTWR HIGH TEMPERATURE HOT WATER RETURN HTWS HIGH TEMPERATURE HOT WATER SUPPLY HW HOT WATER HWR HOT WATER RETURN HWS HOT WATER SUPPLY HVAC HEATING VENTILATING AND AIR CONDITIONING HV HEATING AND VENTILATING IN.WG INCHES WATER GAGE KW KILOWATTS LAT LEAVING AIR TEMPERATURE LD LINEAR DIFFUSER LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MBH 1000 X BTUH MIN MINIMUM MVD MANUAL VOLUME DAMPER MD MORTORIZED DAMPER MZ MULTI -ZONE N.T.S. NOT TO SCALE OA OUTSIDE AIR OBMVD OPPOSED BLADE MANUAL VOLUME DAMPER OPD OPEN DRIP PROOF PROP PROPELLER PCR PRE -CONDITIONED AIR SYSTEM RETURN WATER PCS PERCENT PD PRESSURE DROP PERF. PL. PERFORATED PLATE PLBG PLUMBING PSIA POUNDS PER SQUARE INCH ABSOLUTE PSIG POUNDS PER SQUARE INCH MJR/KCM B.LS/AJB GAUGE RA RETURN AIR RD RADIATION DAMPER REG REGISTER REQ'D REQUIRED RG RETURN AIR GRILLE RH RELATIVE HUMIDITY RPM REVOLUTIONS PER MINUTE RR RETURN AIR REGISTER RTU ROOFTOP UNIT SA SUPPLY AIR SF SUPPLY FAN SDT SMOKE DETECTOR SD SUPPLY DIFFUSER SDMP SMOKE DAMPER SQ.FT. SQUARE FOOT SR SUPPLY REGISTER STR STARTER SWSI SINGLE WIDTH, SINGLE INLET SZ SINGLE ZONE TEFC TOTALLY ENCLOSED FAN COOLED TEMP TEMPERATURE TG TRANSFER GRILLE T/0 TRANSFER OPENING ABOVE CEILING T'STAT THERMOSTAT TYP TYPICAL VFDC VARIABLE FREQUENCY DRIVE SP CONTROLLER VAV VARIABLE AIR VOLUME VS VARIABLE SPEED W WATTS W/ WITH W/0 WITHOUT WB WETBULB ZD ZONE DAMPER GENERAL NOTES 1. INSTALL EQUIPMENT AND MATERIALS IN COMPLIANCE WITH MANUFACTURER'S MINIMUM CLEARANCE REQUIREMENTS AND RECOMMENDATIONS. 2. COMPLY WITH THE LATEST EDITIONS OF NFPA AND THE LATEST ADOPTED EDITION FLORIDA BUILDING CODE (MECHANICAL, PLUMBING AND GAS). 3. ALL MATERIALS SHALL FIT THE SPACE AVAILABLE. VERIFY DIMENSIONS AND CLEARANCES ON BUILDING PLANS PRIOR TO COMMENCING WORK. 4. CONTRACTOR IS RESPONSIBLE FOR TESTING AND BALANCING OF AIR SYSTEMS IN ACCORDANCE WITH AABC GUIDELINES. A TEST AND BALANCE REPORT SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL. 5. PROVIDE 45 DEGREE BRANCH TAKE -OFF PER SMACNA FIG. 2-8 ON ALL RECTANGULAR DUCT TAKE -OFFS. 6. PROVIDE AND INSTALL DUCT MOUNTED HINGED ACCESS DOORS FOR ALL SMOKE AND/OR FIRE DAMPERS, NOT OTHERWISE ACCESSIBLE. 7. CONTRACTOR SHALL COORDINATE VOLTAGE AND PHASE OF EACH PIECE OF EQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO ORDERING AND SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO OR INSTALLING EQUIPMENT AND MATERIALS. 8. COORDINATE ALL MVAC SYSTEM DRAWINGS WITH EXISTING/NEW TRUSS TO AVOID INTERFERENCE BETWEEN MECHANICAL SYSTEMS AND ROOF STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH TRUSS INTERFERENCE THAT OCCURS IN THE FIELD DURING CONSTRUCTION. COORDINATE IN ADVANCE. DUCT SIZES MAY BE REVISED TO FIT TRUSS SYSTEM SO LONG AS THE EQUIVALENT INSIDE CROSS SECTIONAL AREA IS NOT DECREASED. 9. GAUGES AND CONSTRUCTION FOR DUCTWORK SHALL CONFORM TO THE LATEST EDITION OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS, 10, TRANSITION RECTANGULAR DUCTWORK ON BOTTOM AND SIDES. MAINTAIN TOP OF DUCTWORK LEVEL AND HIGH AS POSSIBLE. FLEXIBLE DUCT RUN -OUTS TO CEILING DIFFUSERS SHALL BE AS STRAIGHT AS POSSIBLE AND FREE OF SAGS & KINKS. FLEX DUCT SHALL BE THE SAME SIZE AS THE DIFFUSER NECK IT SERVES. 11. ALL DUCT TRANSITIONS FROM SQUARE TO ROUND SHALL BE SMOOTH SQUARE TO ROUND TRANSITIONS. SPIN -IN FITTINGS AT THE END OF CAPPED DUCTS ARE NOT ACCEPTABLE. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS. 12. THE CONTRACTOR SHALL FULFILL ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SHALL COMPLETE THE WORK SHOWN ON THESE DRAWINGS. ALL SYSTEMS SHALL BE FINISHED, TESTED AND BALANCED, ADJUSTED, AND PROVEN TO BE FULLY OPERATIONAL AND USEABLE. 13. ADJUST ALL DIFFUSERS IN CORRIDORS OR WITHIN THREE (3) FEET OF A WALL TO PROVIDE 2 -WAY OR 3 -WAY BLOW AWAY FROM OR PARALLEL TO WALLS. ALL DIFFUSERS SHALL HAVE 4 -WAY BLOW UNLESS NOTED OTHERWISE. 14, PORTIONS OF DUCTWORK VISIBLE THROUGH GRILLES AND REGISTERS IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. 15. ALL DAMPERS IN AND ABOVE CEILING SHALL BE ACCESSIBLE. CONTRACTOR SHALL COORDINATE ALL ACCESS PANELS IN CEILINGS OR WALLS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND INTERIOR DRAWINGS FOR PROPER LOCATION. 16. MOUNT THERMOSTATS WHERE INDICATED ON PLANS 48" A.F.F. UNLESS NOTED OTHERWISE. IN HANDICAPPED ACCESSIBLE AREAS, MOUNT CONTROLS AT 48" ABOVE FINISHED FLOOR. 17. COORDINATE DUCTWORK AND PIPING WITH PLUMBING, FIRE PROTECTION AND ELECTRICAL. MAKE OFFSETS AND TRANSITIONS TO COORDINATE WITH OTHER TRADES WITHOUT ANY ADDITIONAL EXPENSE TO THE CONTRACT. 18, SEAL ALL TRANSVERSE JOINTS AND FITTINGS WITH DUCT SEALER. 19. TRAP AND ROUTE CONDENSATE DRAINS LINES, FULL SIZE OF UNIT CONNECTION, AS INDICATED. SLOPE 1/8" PER FOOT. 20. ALTERNATE MANUFACTURERS AND MODELS WILL BE REVIEWED. THERE MAY BE ARCHITECTURAL, STRUCTURAL AND ELECTRICAL CHANGES RESULTING FROM THE ALTERNATES. THE COST OF IMPLEMENTING AND ENGINEERING THESE CHANGES SHALL BE BORNE BY THE MECHANICAL SUBCONTRACTOR. 21. PIPE AND DUCT ROUTING SHOWN IS SCHEMATIC. PROVIDE ANY ADDITIONAL OFFSETS AND FITTINGS, INCLUDING DIVIDED DUCTS, REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES AS ENCOUNTERED IN THE FIELD. 22. COORDINATE CEILING MOUNTED AIR DEVICE LOCATION WITH REFLECTED CEILING PLAN AND OTHER TRADES. 23. ALL CONTROL WIRING AND CONDUIT SHALL COMPLY WITH NEC DIVISION 16 SPECIFICATIONS. 24. PROVIDE MATERIALS WHICH HAVE A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE DEVELOPED RATING OF 50 OR LESS WHEN TESTED IN ACCORD WITH ASTM E84. 25. SLEEVE AND FIRE STOP PENETRATIONS THROUGH FIRE RATED SYSTEMS TO MAINTAIN RATING OF SYSTEM. USE MINIMUM GALVANIZED STEEL GAUGE DUCT AS REQUIRED TO MAINTAIN RATING OF SYSTEM. 26. THE TABC SHALL BE EMPLOYED DIRECTLY BY THE GENERAL CONTRACTOR WHO SHALL BE SOLELY RESPONSIBLE FOR ITS PERFORMANCE AND THE TIMELY SCHEDULE OF ITS OPERATION. 27. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH OF THE DUCT SHALL BE IDENTIFIED ON A PERMENANT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FEET OF THE EXHAUST DUCT CONNECTION. 28. CONTRACTOR TO ORDER ALL FIRE/SMOKE DAMPERS WITH INTEGRAL SMOKE DETECTORS AND END STOP INDICATOR OPTIONS. VERIFY VOLTAGE WITH ELECTRICAL DRAWINGS. IF BUILDING IS EQUIPPED WITH FIRE ALARM SYSTEM ALL FIRE/SMOKE DAMPERS WILL BE CONNECTED TO BUILDING FIRE ALARM SYSTEM. NOTE: GENERAL NOTES ON THIS MECHANICAL SHEET ARE FOR GENERAL REFERENCE PURPOSES ONLY. ALL OF THESE NOTES MAY NOT BE USED FOR THIS PROJECT. rrs> LEGEND SUPPLY DIFFUSER (4 -WAY) RETURN OR OUTDOOR AIR GRILLE EXHAUST GRILLE SUPPLY DUCT UP SECTION (RECTANGULAR) RETURN DUCT UP SECTION (RECTANGULAR) EXHAUST DUCT UP SECTION (RECTANGULAR) SUPPLY DUCT DOWN SECTION (RECTANGULAR) RETURN DUCT DOWN SECTION (RECTANGULAR) EXHAUST DUCT DOWN SECTION (RECTANGULAR) SUPPLY DUCT UP SECTION (ROUND) SUPPLY DUCT DOWN SECTION (ROUND) LINEAR SLOT DIFFUSER EXISTING LINEAR SLOT DIFFUSER (LIGHT LINETYPE) RECTANGULAR DUCTWORK WITH TAKE -OFF, BALANCING DAMPER AND INSULATED FLEXIBLE ROUND DUCT. SAME SIZE AS DIFFUSER INLET UNLESS NOTED OTHERWISE. FIRST DIMENSION IS THAT OF SIDE SHOWN ROUND DUCTWORK CONICAL FITTING WITH DAMPER ON BRANCH CONNECTION TO RECTANGULAR MAIN (PROVIDE DAMPER IN LOW PRESSURE DUCTWORK ONLY) EXISTING DUCTWORK TO REMAIN (LIGHT LINETYPE) DUCT OFFSETS UP (RISE) IN DIRECTION INDICATED DUCT OFFSETS DOWN (DROP) IN DIRECTION INDICATED OPPOSED BLADE VOLUME DAMPER (OBD) MANUAL DAMPER FLEXIBLE DUCT CONNECTION FIRE DAMPER WITH ACCESS PANEL COMBINATION FIRE/SMOKE DAMPER WITH ACCESS PANEL EXISTING DUCTWORK TO BE REMOVED (DASHED LINETYPE) DUCT MOUNTED SMOKE DETECTOR PROVIDED AND WIRED BY ELECTRICAL CONTRACTOR AND INSTALLED IN DUCT BY MECHANICAL CONTRACTOR. REFER TO SPECIFICATIONS FOR CONTROL REQUIREMENTS. AIR DEVICE TAG MARK -CFM SIDEWALL TRANSFER GRILLE SIDEWALL SUPPLY REGISTER SIDEWALL RETURN GRILLE OR OUTSIDE AIR LOUVER SIDEWALL EXHAUST GRILLE WALL MOUNTED DDC TEMPERATURE SENSOR MOUNT 4'-0" ABOVE FINISHED FLOOR WALL MOUNTED THERMOSTAT MOUNT 4'-0" ABOVE FINISHED FLOOR WALL MOUNTED CO SENSOR MOUNT 4'-0" ABOVE FINISHED FLOOR WALL MOUNTED DDC HUMIDITY SENSOR MOUNT 4'-0" ABOVE FINISHED FLOOR WALL MOUNTED HUMIDISTAT SENSOR MOUNT 4'-0" ABOVE FINISHED FLOOR PHOTO DETAIL OR SECTION IDENTIFICATION TARGET A = DETAIL NUMBER B = SHEET NUMBER ON WHICH DETAIL IS LOCATED RADIATION DAMPER INSTALLED IN AIR DEVICE RADIATION DAMPER INSTALLED IN DUCT. �X REFERENCE NOTES OX REFERENCE NOTE - MULTI -DISCIPLINE SHEETS �. FLOW DIRECTION ® INDICATES POINT OF CONNECTION BETWEEN NEW AND EXISTING ® POINT OF DISCONNECT CWS CONDENSER WATER SUPPLY PIPING CWR CONDENSER WATER RETURN PIPING BCWS BUILDING CONDENSER WATER SUPPLY PIPING BCWR BUILDING CONDENSER WATER RETURN PIPING CHWS CHILLED WATER SUPPLY PIPING CHWR CHILLED WATER RETURN PIPING HWS HEATING WATER SUPPLY PIPING HWR HEATING WATER RETURN PIPING CD CONDENSATE DRAIN PIPING R REFRIGERANT PIPING FS FLOW SENSOR SP 0 STATIC PRESSURE TRANSMITTER ASSEMBLY RECTANGULAR BRANCH DUCT CONNECTION. L=1/4W, 45 (PROVIDE BALANCING DAMPER AT ALL MIN. 4" —�- �--W BRANCH CONNECTIONS) — — - TEE (PLAN, UP, DOWN) --0 9 ELBOW (PLAN, UP, DOWN) -Da-- VALVE TWO WAY MOTORIZED CONTROL VALVE THREE WAY MOTORIZED CONTROL VALVE PRESSURE REDUCING VALVE ��� --- FLOW CONTROL VALVE Q) BALL VALVE FOR PIPING 2 -INCHES AND SMALLER, BUTTERFLY VALVE FOR PIPING 2-1/2 INCHES AND v U LARGER BUTTERFLY VALVE -�}-- CHECK VALVE STRAINER BALANCE VALVE WITH INTEGRAL TAPS FOR CONNECTION �3V OF DIFFERENTIAL PRESSURE METER. VALVE SHALL =o HAVE NAMEPLATE INDICATING WATER FLOW RATE VERSUS VALVE PRESSURE DROP A AUTOMATIC FLOW CONTROL VALVE WITH INTEGRAL been electronically TEMPERATURE AND PRESSURE TEST PORTS I I— UNION G�-- VENTURI FLOW METER not considered signed PRESSURE AND/OR TEMPERATURE PORT the signature must be THERMOMETER electronic copies. PRESSURE GAUGE WITH GAUGE COCK �--- FLEXIBLE CONNECTION PRESSURE RELIEF VALVE ❑M MOTORIZED ACTUATOR OPENING IN WALL ABOVE CEILING AH EQUIPMENT TYPE MARK EQUIPMENT TAG 1 " DOOR UNDER CUT. ARROW INDICATES DIRECTION UC OF FLOW t� FLEX DUCT NOTE: ELBOW WITH TURNING VANES SYMBOLS SHOWN ON THIS MECHANICAL LEGEND ARE FOR REFERENCE PURPOSES ONLY. ALL OF THESE SYMBOLS MAY NOT BE USED FOR THIS PROJECT. & sll$'Q 47x00 4 C, .r Ido+ ✓� ° +°. °°°° �)1, 'M„V'?• 6 ney PdF-44i6 24 m 0 Q. U Q) 0 Q) as f� Q) v U C a r"v � c a •� v�iO�Qo ry N 10) �3V =o This ileus has been electronically signed and sealed by Nelsun Blalikeuship, Jr. on 10/19/18 using a digital signature. Printed copies of this document are not considered signed and seated and the signature must be verified on iwy electronic copies. Nelson Blankenship, ALA ;urz i'��'r P4 8 u H p �+ r ry!� U 1/g1�1 C� c�1 1 0 t cq �+ rt � DRAWN CHECKED MJR/KCM B.LS/AJB PROJECT NUMBER 1822 DRAWING NUMBER M-001 DATE 11-05-18 MAIN DUCT -2 - NTS SEAL INSULATION JOINTS AND BREAKS IN VAPOR BARRIER WITH GLASS FABRIC AND MASTIC (NO TAPE ALLOWED) BELLMOUTH FITTING = INSULATION AS SPECIFIED DRAWBAND ON OUTSIDE OF INSULATION AROUND JACKET — DRAWBAND ON FLEXIBLE DUCT (INNER SLEEVE) INSULATION AND JACKET FLEXIBLE DUCT �– BUTTERFLY DAMPER WITH LOCKING QUADRANT OPERATOR WATER BASE DUCT SEALER BETWEEN FLEXIBLE DUCT AND SHEETMETAL DUCT (APPLY SEALER TO BOTH SHEETMETAL AND INSIDE OF FLEX PRIOR TO ASSEMBLY) OVERLAP FULL DISTANCE OF NECK NOTES: 1. TYPICAL FOR: LOW PRESSURE AND HIGH PRESSURE CONNECTION TO MAIN DUCT, FAN TERMINAL UNITS, VARIABLE AIR VOLUME UNITS, AND DIFFUSERS. 2. DRAWBANDS SHALL BE EQUIVALENT TO PANDUIT PLT–H. FLEXIBLE DUCT CONNECTION DETAIL UPPER ATTACHMENT PER SMACNA MAXIMUM D/8 OFFSET ALLOWED IN LAST D INCHES TO DEVICE WHERE D IS THE INTERNAL FLEX DIAMETER — NECK SIZE TO MATCH FLEX DUCT SIZE INDICATED CEILING (T–BAR SHOWN) GYPSUM BOARD SIMILAR � AIR DEVICE SCHEDULE f �tlA OA MARK DESCRIPTION FACE SIZE NECK MATERIAL MANUFACTURER & MODEL NO, NOTES. A SQUARE CONE SUPPLY DIFFUSER 24"x24" SEE SCHED. ALUMINUM PRICE #ASCD 1., 2., 3., & 4. B EGGCRATE RETURN GRILLE (1/2"x1/2"x1/2") 24"x24" SEE SCHED. ALUMINUM PRICE X80 1. & 2. X EXISTING SUPPLY DIFFUSER 24"x24" – – EXISTING 5. NOTES: 1. COORIDINATE SURFACE FINISHES WITH ARCHITECTURAL DRAWINGS. 2. PROVIDE RAPID MOUNT FRAME FOR PLASTER AND SHEET ROCK CEILINGS. 3. SUPPLY COMPLETE FACTORY INSTALLED 1/2" THICK FOIL BACKED INSULATION. 4. PROVIDE REMOTE DAMPERS FOR AIR DEVICE IN HARD CEILING. 5. SUPPLY DIFFUSER TO BE REMOVED AND CLEANED. REPLACE IF REQUIRED. UPPER ATTACHMENT PER SMACNA MAXIMUM D/8 OFFSET ALLOWED IN LAST D INCHES TO DEVICE WHERE D IS THE INTERNAL FLEX DIAMETER — NECK SIZE TO MATCH FLEX DUCT SIZE INDICATED CEILING (T–BAR SHOWN) GYPSUM BOARD SIMILAR � f �tlA OA M>1 !11 0 X 21 A O A OC 0 U � v a �^ C c V � X t A I CJ `nJ3•ti �=' O X 4 item has bean electronically signed and sealed by Nelson 4 digital signature. Printed copies of this _j X and sealed and the signature must be verilied on my electronic copies. Nelson Blatilcenship, AIA 4 X i- a � n � fr P4 G�- jb d cn X x plc) r- — -x O r M �-a rr4 r i DRAWN CHECKED X BLS/AJB PRUJEC"f NUMBER 1822 DRAWING NUMBER M-201. RENOVATION- FLOOR ENOVATIONFLOOR PLAN -MECHANICAL SCALE: t/4"=P-0" ROUND SPIN–IN COLLAR MOUNT IN SIDE OF DUCT UNLESS SPECIFICALLY SHOWN OTHERWISE ADJUSTABLE CLAMP MAX. SAG Yz" PER FOOT BETWEEN SUPPORT POINTS `--SEE NOTE 3 ADJUSTABLE CLAMP STAINLESS STEEL DUCT SEALER INSULATE TOP PANEL OF LAY -IN DIFFUSER AIR DISTRIBUTION DEVICE, SEE SCHEDULE. LAY -IN SHOWN - SURFACE MOUNT SIMILAR DUCT SEALER AT SPIN COLLAR CONNECTION TO MAIN SUPPLY DUCT SIZE AS F SHOWN ON PLANS VOLUME DAMPER WITH LOCKING QUADRANT AND 2" STANDOFF NOTES: 1. FLEXIBLE DUCTS SHALL BE ONE-PIECE AND SHALL NOT BE SPLICED TOGETHER. 2. EXTEND FLEXIBLE DUCT INSULATION TO DUCT/DIFFUSER PANEL INSULATION AND SEAL WITH MASTIC. 3. MINIMUM 1-1/2" WIDE 22 GAUGE GALVANIZED STRAP HANGER WITH HEMMED EDGES PER SMACNA FIGURE 3-10, 4. FLEXIBLE AIR DUCT SHALL BE FULLY EXTENDED AND NOT COMPRESSED WITH ELBOW RADIUS NO LESS THAN R/D=1.0. 1 NTS FLEXIBLE DUCT DETAIL PROVIDE CEILING ACCESS PANEL FOR DAMPER ACCESS IN NON–ACCESSIBLE CEILINGS GENERAL NOTES: A. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE OF THE WORK.' PRIOR TO SUBMITTING BID, VISIT THE JOB SITE TO OBSERVE THE EXISTING CONDITIONS OF THE PROJECT. REVIEW GENERAL NOTES. SPECIFICATIONS AND PLANS FOR ADDITIONAL REQUIREMENTS THAT MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID, B. DUCT SIZES SERVING DIFFUSERS AND GRILLES ARE SAME SIZE AS DIFFUSER OR GRILLE NECK UNLESS NOTED OTHERWISE. C. CONTRACTOR IS RESPONSIBLE FOR COORDINATING DIFFUSERS/REGISTERS BORDER STYLES WITH ARCHITECTURAL CEILING TYPES. D. PROVIDE VOLUME BALANCING DAMPER AT ALL NINETY -DEGREE DUCT TAKE -OFFS. THIS ALSO APPLIES TO TAKE -OFFS TO DIFFUSERS OR REGISTERS LOCATED DIRECTLY UNDER DUCTS. E. MECHANICAL CONTRACTOR TO FIELD VERIFY WITH STRUCTURE ALL DUCT ROUTING PRIOR TO FABRICATION. F. CONTRACTOR SHALL COMPLY WITH ALL LANDLORD'S TENANT CRITERIA. COORDINATE AND SCHEDULE ALL WORK WITH LANDLORD'S FIELD REPRESENTATIVE. G. PROVIDE ALL NECESSARY TRANSITIONS AND OFFSETS AND OFFSETS IN SUPPLY AND RETURN AIR DUCTWORK TO AVOID STRUCTURE, WATER, GAS, SPRINKLER PIPING, OTHER DUCTWORK, OTHER TRADES, ETC. H. WHERE CEILING SPACE IS NOT SUFFICIENT TO PERMIT TOP CONNECTION TO CEILING DIFFUSER WITH PROPER BEND RADIUS FOR FLEXIBLE DUCTS, CONTRACTOR SHALL FABRICATE AND/OR PROVIDE AN ADAPTER BOX FOR DIFFUSER TO PERMIT SIDE CONNECTION TO FLEXIBLE DUCT. I. CONTRACTOR SHALL PERFORM A COMPLETE CERTIFIED TEST AND BALANCE OF EACH MECHANICAL SYSTEM INCLUSIVE OF EXHAUST FANS, ROOF TOP UNITS, AND CEILING DEVICES. SEE SPECIFICATIONS FOR DETAILS AND PROVIDE THREE (3) WRITTEN COPIES OF THE COMPLETED TEST AND BALANCE REPORT TO THE OWNER FOR REVIEW. J. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL EQUIPMENT AND ACCESSORIES FOR HVAC EQUIPMENT. THIS CONTRACTOR SHALL VERIFY ALL EQUIPMENT REQUIREMENT AND QUANTITIES PRIOR TO BID. REFERENCE NOTES: o ( EXISTING SUPPLY DIFFUSER TO REMAIN IN PLACE. O2 RELOCATE EXISTING SUPPLY DIFFUSER TO NEW LOCATION SHOWN. PROVIDE NEW FLEX DUCTWORK IF REQUIRED. 30 RELOCATE EXISTING RETURN GRILLE TO NEW LOCATION SHOWN. PROVIDE NEW FLEX DUCTWORK IF REQUIRED. ® INSTALL NEW SUPPLY DIFFUSER AND CONNECT TO NEAREST MAIN SUPPLY DUCT SERVING SPACE NEAR NEW OFFICE AREA. sf fi t, si k arney . . # . 69124 UAIE 11-U5-18 f �tlA OA M>1 !11 0 U OC 0 U � v a �^ C c V � W-��� -n=N C. al'J p.0 Y� Oa(.i CJ `nJ3•ti �=' O (0 This item has bean electronically signed and sealed by Nelson Blankenship, Jr. on 10/19/18 using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verilied on my electronic copies. Nelson Blatilcenship, AIA 4 P.4 i- a � n � fr P4 G�- d cn N ci plc) r- r M �-a rr4 r i DRAWN CHECKED MJR/KCM BLS/AJB PRUJEC"f NUMBER 1822 DRAWING NUMBER M-201. UAIE 11-U5-18 ELECTRICAL LEGEND WIRING AND POWER S* SWITCH (NONE) SINGLE POLE TOGGLE SWITCH 2 TWO POLE TOGGLE SWITCH 3 THREE WAY TOGGLE SWITCH WP SINGLE POLE WEATHERPROOF SWITCH K SINGLE POLE KEYED SWITCH OS OCCUPANCY SENSOR SWITCH M MANUAL MOTOR CONTROLLER W/O OVERLOADS S abc LOWER CASE LETTERS INDICATES SWITCHING DESIGNATIONS, QUANTITY OF LETTERS EQUAL QUANTITY OF GANGED SWITCHES (� SINGLE RECEPTACLE * GFI GROUND FAULT CIRCUIT INTERRUPTER WP WEATHERPROOF IG ISOLATED GROUND C COUNTER HEIGHT (ABOVE COUNTER OR 42" AFF) DUPLEX RECEPTACLE GFI GROUND FAULT CIRCUIT INTERRUPTER WP WEATHERPROOF IG ISOLATED GROUND C COUNTER HEIGHT (ABOVE COUNTER OR 42" AFF) EWC ELECTRIC WATER COOLER, COORDINATE LOCATION WITH PLUMBING CONTRACTOR USB TAMPER RESISTANT RECEPTACLE WITH USB CHARGING OUTLET IS QUADRAPLEX RECEPTACLE GFI GROUND FAULT CIRCUIT INTERRUPTER WP WEATHERPROOF IG ISOLATED GROUND C COUNTER HEIGHT (ABOVE COUNTER OR 42" AFF) 0* 0 DIP U M VSD VSD �-� EF -1 TC WH HVP1-6 SPECIAL RECEPTACLE X TYPE X (SEE RECEPTACLE SCHEDULE) C COUNTER HEIGHT POWER POLE RECESSED FLOOR MOUNTED DUPLEX RECEPTACLE SURFACE—MOUNTED FLOOR DUPLEX RECEPTACLE CEILING—MOUNTED DUPLEX RECEPTACLE PLUG MOLD C COUNTER HEIGHT JUNCTION BOX DISCONNECT SWITCH DISCONNECT SWITCH — WEATHERPROOF (NEMA 3R) FUSED DISCONNECT SWITCH MAGNETIC MOTOR STARTER COMBINATION FUSED DISCONNECT/ MAGNETIC STARTER SWITCH HOA HAND/OFF/AUTO SS START/STOP MANUAL STARTER COMBINATION VARIABLE SPEED DRIVE AND DISCONNECT VARIABLE SPEED DRIVE MOTOR WITH DESIGNATOR TIME CLOCK WATER HEATER BRANCH CIRCUIT HOME RUN WITH PANEL NAME AND CIRCUIT NUMBER, QUANTITY OF ARROWHEADS DENOTES QUANTITY OF BRANCH CIRCUITS BRANCH CIRCUIT WIRING, PROVIDE QUANTITIES OF CONDUCTORS REQUIRED FOR CIRCUITING AND SWITCHING INDICATED POWER LEG ONLY (NO SWITCH LEG BETWEEN ROOMS) MUSHROOM HEAD PUSH BUTTON (EMERGENCY STOP) RELAY GROUND ROD TRANSFORMER TYPE "K" TRANSFORMER ELECTRIC UNIT HEATER (FURNISHED UNDER DIV 15 UNLESS NOTED OTHERWISE) LIGHTING ® XX NEW ELECTRICAL PANEL XXX (SEE LIGHTING FIXTURE SCHEDULE FOR LETTER DESIGNATION AND DESCRIPTION OF FIXTURES) AC - MDP MAIN DISTRIBUTION PANEL (SEE PANEL SCHEDULE) AFF - TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION ATS AUTOMATIC TRANSFER SWITCH ® ELECTRICAL SYSTEMS PANEL XXX BATTERY POWERED EMERGENCY LIGHT —4 SACP SECURITY ALARM CONTROL PANEL TK FACP FIRE ALARM CONTROL PANEL 0 MC MASTER CLOCK CONTROL PANEL WG PA PUBLIC ADDRESS CONTROL PANEL OS FAAP FIRE ALARM ANNUNCIATOR PANEL LIGHTING ® XX LIGHTING FIXTURE ® 0 4 (SEE LIGHTING FIXTURE SCHEDULE FOR LETTER DESIGNATION AND DESCRIPTION OF FIXTURES) AC - ALTERNATING CURRENT AFF - EMERGENCY/NIGHT LIGHT LIGHTING FIXTURE AFG - EXIT LIGHTING FIXTURE UNIVERSAL MOUNT, SINGLE/DOUBLE FACE -.- (WHERE USED, ARROW INDICATES CHEVRON DIRECTION) AWG - BATTERY POWERED EMERGENCY LIGHT —4 EMERGENCY LIGHT REMOTE HEAD TK TRACK LIGHTING 0 TRACK LIGHTING HEAD WG WIRE CAGE LIGHT GUARD OS OCCUPANCY SENSOR - CEILING MOUNTED osc OCCUPANCY SENSOR - CEILING MOUNTED - CORRIDOR osw OCCUPANCY SENSOR - WALL MOUNTED Lc LIGHTING CONTACTOR PC PHOTOCELL S * SWITCH EMS - OS OCCUPANCY SENSOR SWITCH EF - D DIMMER EMT - D3 THREE WAY DIMMER (INCANDESCENT) FIRE ALARM SYSTEMS D FIRE ALARM PULL STATION [Ell FIRE ALARM HORN F FIRE ALARM HORN AND STROBE COMBINATION EA WP FIRE ALARM HORN AND STROBE COMBINATION, WEATHERPROOF El FIRE ALARM SPEAKER FS FIRE ALARM SPEAKER AND STROBE COMBINATION F FIRE ALARM STROBE CD SMOKE DETECTOR Q HEAT DETECTOR. DD DUCT DETECTOR RTS REMOTE TEST STATION FOR DUCT DETECTOR FSR FIRE ALARM SHUT DOWN RELAY FIRE DOOR HOLD OPEN AREA OF RESCUE CALL STATION ADA AREA OF RESCUE MASTER TELEPHONE STATION FE -B-1 FIRE DEPARTMENT LOCK BOX TELECOMMUNICATIONS ® DATA/COMM OUTLET [TV TELEVISION OUTLET SP SPEAKER NOTE: SYMBOLS SHOWN ON THIS ELECTRICAL LEGEND ARE FOR REFERENCE PURPOSES ONLY. ALL OF THESE SYMBOLS MAY NOT BE USED FOR THIS PROJECT, ABBREVIATIONS A - AMPERES A/C - AIR CONDITIONING AC - ALTERNATING CURRENT AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE AHU - AIR HANDLING UNIT AWG - AMERICAN WIRE GAUGE C - CONDUIT CFL - COMPACT FLUORESCENT LAMP CH - COUNTER HEIGHT CONC - CONCRETE COND - CONDUIT CU - COPPER DISC - DISCONNECT ECB - ENCLOSED CIRCUIT BREAKER ELEC - ELECTRICAL EM - EMERGENCY EMS - ENERGY MANAGEMENT SYSTEM EF - EXHAUST FAN EMT - ELECTRICAL METALLIC TUBING EWC - ELECTRIC WATER COOLER ETR - EXISTING TO REMAIN EX - EXISTING FA - FIRE ALARM FAAP - FIRE ALARM ANNUNCIATOR PANEL FACP - FIRE ALARM CONTROL PANEL G - GROUND GFI - GROUND FAULT INTERRUPTER OND - GROUND GRC - GALVANIZED RIGID CONDUIT H.I.D. - HIGH INTENSITY DISCHARGE HVAC - HEATING, VENTILATING, AND AIR CONDITIONING I.G. - ISOLATED GROUND J - JUNCTION KAIC - (THOUSAND) AMPERE INTERRUPTING CAPACITY KVA - KILOVOLT -AMPERES KW - KILOWATT LTG - LIGHTING MCM - THOUSANDS OF CIRCULAR MILS MCU - MASTER CONTROL UNIT MCP - MOTOR CIRCUIT PROTECTION MH - METAL HALIDE N - NEUTRAL NA - NOT APPLICABLE NF NON-FUSED NL - NIGHT LIGHT NEC - NATIONAL ELECTRICAL CODE NEMA - NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION NFPA - NATIONAL FIRE PROTECTION ASSOCIATION NIC - NOT IN CONTRACT O.C. - ON CENTER O.F.C.I. - OWNER FURNISHED CONTRACTOR INSTALLED P - POLE PNL - PANELBOARD PVC - POLYVINYL CHLORIDE RGS - RIGID GALVANIZED STEEL RM - ROOM SPEC - SPECIFICATION SS - STAINLESS STEEL TVSS - TRANSIENT VOLTAGE SURGE SUPPRESSION TYP - TYPICAL UON - UNLESS OTHERWISE NOTED V - VOLTS W - WIRE WP - WEATHERPROOF 1) ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE (NFPA 70), AND THE LATEST ADOPTED EDITION OF THE FLORIDA BUILDING CODE. 2) CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND COORDINATE WITH EXISTING EQUIPMENT PRIOR TO BIDDING. 3) ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABEL LISTED BY AN APPROVED THIRD -PARTY TESTING AGENCY. BUILDING: 4) INSTALLATION HEIGHT OF EQUIPMENT (TO CENTERLINE) ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE SHALL BE: RECEPTACLE = 18" CLOCK = 7,-6" SWITCH = 44" MODULAR JACK FOR WALL MOUNTED TELEPHONE = 52" MODULAR TELEPHONE JACK = 18" TELEVISION OUTLET = 84" COMPUTER OUTLET = 18" CALL SWITCH = 44" REMOTE TEST STATION FOR DUCT DETECTOR = 52" C = ABOVE COUNTER BACKSPLASH, COORDINATE WITH ARCHITECTURAL ELEVATIONS AND MILLWORK. 5) ALL CONDUIT AND WIRING SHALL BE CONCEALED IN WALLS OR ABOVE CEILINGS UNLESS NOTED OTHERWISE OR APPROVED BY THE ARCHITECT/ENGINEER. ALL DEVICE OUTLET BOXES SHALL BE RECESSED UNLESS NOTED OTHERWISE OR APPROVED BY THE ARCHITECT/ENGINEER. WHERE APPROVED OR NOTED SURFACE METAL RACEWAY AND DEVICE BOXES SHALL BE USED IN LIEU OF CONDUIT AND CONCEALED BOXES AT NO EXTRA COST TO THE OWNER. 6) ALL CONDUIT ROUTES SHOWN ARE APPROXIMATE ONLY. CONTRACTOR SHALL FIELD VERIFY FINAL ROUTE. 7) CONDUIT RUNS SHOWN ARE SCHEMATIC AND DO NOT INDICATE THE NECESSARY FITTINGS AND JUNCTION BOXES THAT ARE INCLUDED IN THE SCOPE OF THE WORK, 8) CONTRACTOR SHALL PERMANENTLY IDENTIFY ALL WIRING WITH THE SOURCE AND CIRCUIT AT ALL ELECTRICAL EQUIPMENT, PULL AND JUNCTION BOXES AND ELECTRICAL TERMINATIONS PROVIDED OR ASSOCIATED WITH THIS CONSTRUCTION. 9) CONTRACTOR SHALL PATCH AND REPAIR ALL DAMAGED SURFACES AND AREAS WHERE EQUIPMENT WAS REMOVED OR MODIFIED, TO MATCH EXISTING CONDITIONS. 10) ALL ABANDONED AUDIO OR CONTROL CABLES SHALL BE REMOVED. ALL BOX OR EQUIPMENT OPENINGS SHALL BE CLOSED WITH LISTED CLOSURE DEVICE AS APPROVED BY THE EQUIPMENT MANUFACTURER. 1 1) WHERE EXISTING EQUIPMENT OR MATERIALS ARE REMOVED OR CHANGED, ALL BRANCH CONDUITS WHICH NO LONGER ARE IN SERVICE, SHALL BE REMOVED AS DIRECTED BY THE ENGINEER, IF, IN THE COURSE OF THIS WORK, OUTLETS ARE COVERED UP OR OTHERWISE RENDERED INACCESSIBLE, ALL WIRING TO SAME SHALL BE REMOVED TO THE SOURCE. IF A CIRCUIT THAT MUST REMAIN IN SERVICE IS INTERRUPTED THEREBY, IT SHALL BE RECONNECTED BY THE MOST INCONSPICUOUS MEANS SO AS TO REMAIN OPERATIONAL, WITH THE SAME CAPACITY AS BEFORE. ALL BUILDING SURFACES DAMAGED, AND OPENINGS LEFT BY REMOVAL OF BOXES, PIPING OR OTHER EQUIPMENT SHALL BE REPAIRED BY THE CONTRACTOR. ALL HOLES LEFT IN JUNCTION BOXES, SWITCHES, PANELS, ETC. SHALL BE CLOSED. 12) ALL REUSABLE DEVICES, FIXTURES AND EQUIPMENT SHALL BECOME THE PROPERTY OF THE OWNER. ALL OTHER SALVAGE AND DEBRIS SHALL BE REMOVED FROM THE PREMISES DAILY. 13) THIS CONTRACTOR SHALL FURNISH AND PROVIDE ALL DEMOLITION REQUIRED TO ACCOMMODATE THIS PROJECT WHETHER INDICATED ON DRAWINGS, OR DIRECTED IN THE FIELD. GROUNDING: 14) ALL METAL RACEWAYS, INCLUDING CONDUIT, WIRE TROUGHS, WIREMOLD, ETC., SHALL BE GROUNDED. ALL CONNECTIONS IN METAL RACEWAYS SHALL BE COMPLETED IN SUCH A MANNER AS TO MAINTAIN A CONTINUOUS PATH TO GROUND THROUGHOUT THE ENTIRE LENGTH OF THE RACEWAY, WIRING: 15) UNLESS NOTED OTHERWISE ON THE DRAWINGS OR ON THE EQUIPMENT WIRING SCHEDULE, EACH BRANCH CIRCUIT HOME RUN SHALL BE THREE (3) #12 AWG THHN/THWN (1 HOT, 1 NEUTRAL & 1 EQUIPMENT GROUND) IN 3/4" EMT CONDUIT. PROTECT EACH CIRCUIT WITH A 20 AMPERE, 1 -POLE OVERCURRENT DEVICE UNLESS NOTED OTHERWISE. COMBINED NEUTRALS ARE NOT PERMITTED. EXISTING DEVICES TO REMAIN: 16) UNLESS OTHERWISE NOTED: a. ON DEMOLITION AND NEW WORK PLANS - DEVICES AND EQUIPMENT SHOWN IN LIGHT LINETYPE ARE EXISTING TO REMAIN. b. ON DEMOLITION PLANS - DEVICES AND EQUIPMENT SHOWN IN DARK LINETYPE ARE EXISTING TO BE REMOVED c. ON NEW WORK PLANS - DEVICES AND EQUIPMENT SHOWN IN DARK LINETYPE ARE NEW. `� ��'• ,, .. S, oma, Q Y O '8'��nt�iAri� rFc��\44t�leth f"Q-1 A 0 coo n 0 0- (D (D q) 07 0 O N �g E V C 'Ovv' I Lr .Onm-1z � a. iZ =o o 0 Tlds item has beea electronically signed and sealed by Nelson Blankenship, Jr. oa 10/f9/18 using a digital signature. Printed copies of this <IOCaWellt are not cunsidered signed dna sealed dna the signatnro auist be verified ou aay electrum; copies. Nelson Bltmkenship, AIA in rL V r l0 U 1� I in y C� V 4_4 ID � Q bb � W DRAWN CHECKED MJR/KCM BLS/AJB PROJEc-r NUMBER 1822 DRAWING NUMBER E-0 0 DATE 11 -US -t8 , , , , _1 _ = RENOVATION - FLOOR PLAN - LIGHTING Z SCALE: 1/4"=1'-0" DEMOLITION REFERENCE NOTES: 0 D1 LIGHTING FIXTURE EXISTING TO REMAIN. PREPARE FOR CONNECTION TO NEW SWITCHING AND CIRCUITRY. D2 EXISTING ELECTRICAL OUTLET TO BE REMOVED COMPLETE BACK TO SOURCE OR NEAREST ACCESSIBLE JUNCTION BOX. PROVIDE ALL CONDUIT, CONDUCTORS, JUNCTION BOXES, ETC. AS REQUIRED TO MAINTAIN CIRCUIT CONTINUITY TO EXISTING DEVICES TO REMAIN. D3 EXISTING TELEPHONE/DATA OUTLETS AND CABLING TO BE REMOVED COMPLETE BACK TO SOURCE. 04 EXISTING FIRE DEVICES TO BE REMOVED COMPLETE BACK TO SOURCE OR NEAREST ACCESSIBLE JUNCTION BOX. PROVIDE JUNCTION BOX ABOVE ACCESSIBLE CEILING TO MAINTAIN CIRCUIT CONTINUITY TO REMAINING DEVICES AS REQUIRED. D5 EXISTING LIGHTING FIXTURES TO BE REMOVED. WALL SWITCHES REMOVED SHALL BE TERMINATED AT NEAREST JUNCTION BOX, ALL EXTRANEOUS JUNCTION BOXES, CONDUIT, CONDUCTORS, ETC. TO BE REMOVED BACK TO SOURCE AS REQUIRED. FIXTURE TO BE HELD FOR REUSE DURING RENOVATION. SEE RENOVATION PLAN ADDITIONAL INFORMATION. GENERAL DEMOLITION NOTES: DA ALL ELECTRICAL DEVICES INDICATED IN DARK LINETYPE ON DRAWING SHALL BE REMOVED OR RELOCATED UNLESS NOTED OTHERWISE. REROUTING/RELOCATION OF EXISTING ELECTRICAL SYSTEMS MAY BE REQUIRED AT NEW OPENINGS IN EXISTING CONSTRUCTION OR DUE TO INTERFERENCE WITH OTHER NEW WORK AS DESCRIBED IN THE FOLLOWING NOTES. DB DRAWINGS INDICATE SPECIFIC ITEMS TO BE REMOVED, REROUTED, AND/OR RELOCATED IN ORDER TO INDICATE GENERAL SCOPE. ADDITIONAL ITEMS NOT INDICATED BUT NECESSARY FOR PROJECT RENOVATIONS SHALL BE REMOVED, REROUTED, OR RELOCATED AS REQUIRED, ASSUME WITHIN THE BASE BID A NOMINAL AMOUNT OF BRANCH CIRCUITS, FIXTURES, DEVICES, AND SYSTEMS WIRING WITHIN WALLS OR OPENINGS BEING REMOVED OR RELOCATED AS REQUIRED TO ACCOMMODATE THE NEW CONSTRUCTION. DC FOR ITEMS INDICATED TO BE DEMOLISHED, REMOVE WIRING AND CONDUIT BACK TO THE SOURCE PANELBOARD UNLESS NOTED OTHERWISE. MAINTAIN CIRCUIT CONTINUITY TO REMAINING ITEMS ON CIRCUITS REQUIRED TO REMAIN. RELOCATE ANY CIRCUITS TO REMAIN TO AVOID CONFLICT WITH NEW CONSTRUCTION AS REQUIRED. PROPERLY TERMINATE ALL WIRING. DD MAINTAIN CIRCUIT CONTINUITY TO ALL REMAINING ELECTRICAL SYSTEMS UNAFFECTED BY BUT PASSING THROUGH RENOVATED SPACES OR WHERE ONLY A PORTION OF A CIRCUIT IS REMOVED. ANY EXISTING ELECTRICAL DEVICES LEFT WITHOUT POWER DUE TO THIS RENOVATION SHALL BE RECONNECTED TO SAME SIZE CIRCUIT(S) AS PRESENTLY SERVED. NO ELECTRICAL DEVICES SHALL BE LEFT WITHOUT POWER. DE REFER TO ARCHITECTURAL DEMOLITION DRAWINGS AND NOTES FOR COORDINATION. PATCH AND REPAIR ALL SURFACES CONTAINING DEMOLITION. COORDINATE WITH ARCHITECTURAL DRAWINGS. MATERIALS AND FINISHES SHALL MATCH EXISTING. DF VISIT THE SITE TO DETERMINE THE EXACT EXTENT OF ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT. EXISTING CONDITIONS INDICATED ON THESE DRAWINGS ARE TAKEN FROM EXISTING BUILDING DOCUMENTS AND FIELD OBSERVATION. OTHER ELECTRICAL ITEMS MAY EXIST FOR WHICH THE ELECTRICAL CONTRACTOR IS RESPONSIBLE WHICH MAY NOT BE SPECIFICALLY ADDRESSED IN THESE DRAWINGS. DG PROPERLY DISPOSE OF ALL ITEMS BEING REMOVED AS PART OF THIS PROJECT. THE OWNER SHALL HAVE THE RIGHT TO RETAIN ANY ITEMS BEING REMOVED, COORDINATE ITEMS TO BE RETAINED WITH OWNER. DH CONDUCTORS IN RENOVATED AREA SHALL BE NEW. DO NOT REUSE EXISTING WIRING UNLESS NOTED OTHERWISE. EXISTING CONDUIT IN THE RENOVATED AREA MAY BE REUSED IF IT COMPLIES WITH ALL REQUIREMENTS OF THE NEC AND SPECIFICATIONS, IF NEW DEVICE OR EQUIPMENT LOCATION COINCIDES WITH EXISTING LOCATION, AND IF PRACTICAL. CONDUIT NOT INTENDED TO BE REUSED SHALL BE REMOVED IF POSSIBLE (I.E., NOT EMBEDDED IN CONCRETE FLOOR, ETC.). = RENOVATION UC. FLOOR PLAN - POWER SYSTEMS SCALE: 1/4"=1'-0" ►MM -1 I NIC U r= FYP:-k- TYP - D 9 D3 D2 �l cc 0 s o NIC D? IF o{ry�o r; a0 S C x Q TYF 111is iteral has been electronically signed and sealed by Nelson Blaulcenship, .Ir, on 10/19/18 using a digital signature. Printed copies of this do(AMMIt are not considered signed and sealed and the signature niust be verified on any electronic copies. Nelson Blatilcenship, A[A Jam D4 7F] P.NIC P-,w�® w s rn , U .0 z F� n P4 C� + 4 it = RENOVATION - FLOOR PLAN - LIGHTING Z SCALE: 1/4"=1'-0" DEMOLITION REFERENCE NOTES: 0 D1 LIGHTING FIXTURE EXISTING TO REMAIN. PREPARE FOR CONNECTION TO NEW SWITCHING AND CIRCUITRY. D2 EXISTING ELECTRICAL OUTLET TO BE REMOVED COMPLETE BACK TO SOURCE OR NEAREST ACCESSIBLE JUNCTION BOX. PROVIDE ALL CONDUIT, CONDUCTORS, JUNCTION BOXES, ETC. AS REQUIRED TO MAINTAIN CIRCUIT CONTINUITY TO EXISTING DEVICES TO REMAIN. D3 EXISTING TELEPHONE/DATA OUTLETS AND CABLING TO BE REMOVED COMPLETE BACK TO SOURCE. 04 EXISTING FIRE DEVICES TO BE REMOVED COMPLETE BACK TO SOURCE OR NEAREST ACCESSIBLE JUNCTION BOX. PROVIDE JUNCTION BOX ABOVE ACCESSIBLE CEILING TO MAINTAIN CIRCUIT CONTINUITY TO REMAINING DEVICES AS REQUIRED. D5 EXISTING LIGHTING FIXTURES TO BE REMOVED. WALL SWITCHES REMOVED SHALL BE TERMINATED AT NEAREST JUNCTION BOX, ALL EXTRANEOUS JUNCTION BOXES, CONDUIT, CONDUCTORS, ETC. TO BE REMOVED BACK TO SOURCE AS REQUIRED. FIXTURE TO BE HELD FOR REUSE DURING RENOVATION. SEE RENOVATION PLAN ADDITIONAL INFORMATION. GENERAL DEMOLITION NOTES: DA ALL ELECTRICAL DEVICES INDICATED IN DARK LINETYPE ON DRAWING SHALL BE REMOVED OR RELOCATED UNLESS NOTED OTHERWISE. REROUTING/RELOCATION OF EXISTING ELECTRICAL SYSTEMS MAY BE REQUIRED AT NEW OPENINGS IN EXISTING CONSTRUCTION OR DUE TO INTERFERENCE WITH OTHER NEW WORK AS DESCRIBED IN THE FOLLOWING NOTES. DB DRAWINGS INDICATE SPECIFIC ITEMS TO BE REMOVED, REROUTED, AND/OR RELOCATED IN ORDER TO INDICATE GENERAL SCOPE. ADDITIONAL ITEMS NOT INDICATED BUT NECESSARY FOR PROJECT RENOVATIONS SHALL BE REMOVED, REROUTED, OR RELOCATED AS REQUIRED, ASSUME WITHIN THE BASE BID A NOMINAL AMOUNT OF BRANCH CIRCUITS, FIXTURES, DEVICES, AND SYSTEMS WIRING WITHIN WALLS OR OPENINGS BEING REMOVED OR RELOCATED AS REQUIRED TO ACCOMMODATE THE NEW CONSTRUCTION. DC FOR ITEMS INDICATED TO BE DEMOLISHED, REMOVE WIRING AND CONDUIT BACK TO THE SOURCE PANELBOARD UNLESS NOTED OTHERWISE. MAINTAIN CIRCUIT CONTINUITY TO REMAINING ITEMS ON CIRCUITS REQUIRED TO REMAIN. RELOCATE ANY CIRCUITS TO REMAIN TO AVOID CONFLICT WITH NEW CONSTRUCTION AS REQUIRED. PROPERLY TERMINATE ALL WIRING. DD MAINTAIN CIRCUIT CONTINUITY TO ALL REMAINING ELECTRICAL SYSTEMS UNAFFECTED BY BUT PASSING THROUGH RENOVATED SPACES OR WHERE ONLY A PORTION OF A CIRCUIT IS REMOVED. ANY EXISTING ELECTRICAL DEVICES LEFT WITHOUT POWER DUE TO THIS RENOVATION SHALL BE RECONNECTED TO SAME SIZE CIRCUIT(S) AS PRESENTLY SERVED. NO ELECTRICAL DEVICES SHALL BE LEFT WITHOUT POWER. DE REFER TO ARCHITECTURAL DEMOLITION DRAWINGS AND NOTES FOR COORDINATION. PATCH AND REPAIR ALL SURFACES CONTAINING DEMOLITION. COORDINATE WITH ARCHITECTURAL DRAWINGS. MATERIALS AND FINISHES SHALL MATCH EXISTING. DF VISIT THE SITE TO DETERMINE THE EXACT EXTENT OF ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT. EXISTING CONDITIONS INDICATED ON THESE DRAWINGS ARE TAKEN FROM EXISTING BUILDING DOCUMENTS AND FIELD OBSERVATION. OTHER ELECTRICAL ITEMS MAY EXIST FOR WHICH THE ELECTRICAL CONTRACTOR IS RESPONSIBLE WHICH MAY NOT BE SPECIFICALLY ADDRESSED IN THESE DRAWINGS. DG PROPERLY DISPOSE OF ALL ITEMS BEING REMOVED AS PART OF THIS PROJECT. THE OWNER SHALL HAVE THE RIGHT TO RETAIN ANY ITEMS BEING REMOVED, COORDINATE ITEMS TO BE RETAINED WITH OWNER. DH CONDUCTORS IN RENOVATED AREA SHALL BE NEW. DO NOT REUSE EXISTING WIRING UNLESS NOTED OTHERWISE. EXISTING CONDUIT IN THE RENOVATED AREA MAY BE REUSED IF IT COMPLIES WITH ALL REQUIREMENTS OF THE NEC AND SPECIFICATIONS, IF NEW DEVICE OR EQUIPMENT LOCATION COINCIDES WITH EXISTING LOCATION, AND IF PRACTICAL. CONDUIT NOT INTENDED TO BE REUSED SHALL BE REMOVED IF POSSIBLE (I.E., NOT EMBEDDED IN CONCRETE FLOOR, ETC.). = RENOVATION UC. FLOOR PLAN - POWER SYSTEMS SCALE: 1/4"=1'-0" ►MM DEMO O z 0 =FLOOR PLAN - ELECTRICAL SCALE: 1 /4 '=1'-0" GENERAL NOTES: A. DO NOT SCALE ELECTRICAL DRAWING FOR ANY DIMENSIONS. B. ALL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE, NATIONAL, STATE AND LOCAL CODES. PROVIDE GROUNDING AND BONDING PER NEC 250. C. SEE SINGLE LINE DIAGRAM FOR FEEDER WIRE AND CONDUIT SIZE. ALL CIRCUITS NOT SIZED ON DRAWING SHALL BE INSTALLED TO MEET MINIMUM SIZE REQUIRED BY NEC. ALL CONDUCTORS SHALL HAVE AN EQUIPMENT GROUND WIRE SIZED PER NEC. D. FIELD VERIFY EXACT LOCATION OF ALL DEVICES AND EQUIPMENT PRIOR TO ROUGH IN. E. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS AND ORIENTATIONS. F. REFER TO ARCHITECTURAL ELEVATIONS AND SECTIONS FOR ADDITIONAL LIGHTING FIXTURE MOUNTING DETAILS AND INFORMATION, G. ALL EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS SHALL BE CONNECTED "HOT" TO THE INDICATED LOCAL LIGHTING CIRCUIT, H. VERIFY ALL MOUNTING HEIGHTS AND PENDANT LENGTHS WITH ARCHITECT AND ENGINEER PRIOR TO ORDERING FIXTURES. I. EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A PERIOD OF 90 MINUTES IN THE EVENT OF FAILURE OF NORMAL LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOTCANDLE (10 LUX) AND A MINIMUM AT ANY POINT OF 0.1 FOOTCANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOTCANDLE (6 LUX) AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOTCANDLE (0.6 LUX) AT THE END OF THE EMERGENCY LIGHTING TIME DURATION, A MAXIMUM—TO—MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40:1 SHALL NOT BE EXCEEDED, J. ELECTRICAL ENERGY MONITORING: MEASUREMENT DEVICES (EMON DMON OR APPROVED SUBSTITUTION) SHALL BE INSTALLED IN NEW BUILDINGS TO MONITOR THE ELECTRICAL ENERGY OF THESE SYSTEMS (TOTAL ELECTRICAL ENERGY, HVAC SYSTEMS, INTERIOR LIGHTING, EXTERIOR LIGHTING AND RECEPTACLE CIRCUITS) PER ASHRAE 90.1 2013, SECTION 8.4.3.1. REFERENCE NOTES: O 0 CONNECT 120V RECEPTACLE CIRCUIT IN OFFICE SPACE VIA WATTSTOPPER PLUG LOAD POWER PACK #BZ -200 (OR APPROVED SUBSTITUTION) FOR AUTOMATIC CONTROL OF RECEPTACLES. RECEPTACLES SHALL BE SPLIT WIRED SO THAT THE POWER PACK SHALL AUTOMATICALLY "TURN OFF" THE TOP OUTLET ON EACH RECEPTACLE IF SPACE IS UNOCCUPIED FOR 20 MINUTES AND THE BOTTOM OUTLET SHALL BE CONSTANT HOT. OUTLETS SHALL BE VISUALLY MARKED AS REQUIRED TO DIFFERENTIATE CONTROLLED OUTLETS FROM UNCONTROLLED OUTLETS. RECEPTACLE POWER PACKS SHALL BE CONTROLLED VIA LOW VOLTAGE VACANCY SENSORS AS SHOWN ON LIGHTING PLAN, PROVIDE ALL CONDUIT AND LOW VOLTAGE WIRING AS REQUIRED TO INTERCONNECT RECEPTACLE POWER PACKS AND LIGHTING POWER PACKS. INSTALLATION SHALL COMPLY WITH FLORIDA BUILDING CODE SECTION C405.7.1, 2014 EDITION AND ASHRAE STANDARD 90.1. O PROVIDE CEILING MOUNTED, DUAL TECHNOLOGY, LOW VOLTAGE VACANCY SENSOR, WATTSTOPPER #DT -200 (OR APPROVED SUBSTITUTION) TO OVERRIDE WALL SWITCHES AND TURN OFF LIGHTS IF ROOM IS UNOCCUPIED FOR MORE THAN 30 MINUTES. COORDINATE LOCATION WITH CONDITIONS IN FIELD TO PROVIDE MAXIMUM COVERAGE OF SPACE. PROVIDE ADDITIONAL SENSORS, RELAYS, POWER PACKS, ETC. AS REQUIRED FOR COMPLETE COVERAGE OF SPACE. PROVIDE ALL CONDUIT AND LOW VOLTAGE WIRING AS REQUIRED TO INTERCONNECT LIGHTING POWER PACKS WITH RECEPTACLE POWER PACKS IN SPACE FOR AUTOMATIC CONTROL OF RECEPTACLES IF INDICATED ON POWER PLANS. INSTALLATION SHALL COMPLY WITH FLORIDA BUILDING CODE SECTION C405.7.1, 2014 EDITION. �3 PROVIDE WALL MOUNTED, DUAL TECHNOLOGY, LOW VOLTAGE VACANCY SENSOR, WATTSTOPPER #DW -100-24 (OR APPROVED SUBSTITUTION) FOR AUTOMATIC CONTROL OF LIGHTING. CONNECT LIGHTING IN SPACE AS SHOWN ON PLANS VIA WATTSTOPPER LIGHTING POWER PACK #BZ -200 (OR APPROVED SUBSTITUTION). PROVIDE ALL ADDITIONAL POWER PACKS, RELAYS, SENSORS AS REQUIRED FOR COMPLETE COVERAGE OF SPACE AND SWITCHING AS SHOWN ON PLANS. PROVIDE ALL CONDUIT AND LOW VOLTAGE WIRING AS REQUIRED TO INTERCONNECT LIGHTING POWER PACKS WITH RECEPTACLE POWER PACKS IN SPACE FOR AUTOMATIC CONTROL OF RECEPTACLES IF INDICATED ON POWER PLANS. INSTALLATION SHALL COMPLY WITH FLORIDA BUILDING CODE SECTION C405.7.1, 2014 EDITION. ® CONNECT EXISTING LIGHT FIXTURE TO NEW CIRCUITRY AND NEW LIGHTING CONTROLS AS SHOWN. 0 CONNECT NEW FIRE ALARM DEVICE TO EXISTING BUILDING FIRE ALARM SYSTEM. PROVIDE ALL SYSTEM UPGRADES, BATTERY UPGRADES, AND REPROGRAMMING AS REQUIRED. COORDINATE EXACT CONNECTION REQUIREMENTS WITH CONDITIONS IN FIELD AND MANUFACTURER'S RECOMMENDATIONS PRIOR TO ROUGH -IN AND PROVIDE AS REQUIRED. m -1 I 0 U r= D - D 9 D3 D2 �l cc 0 s o NIC D? IF o{ry�o r; a0 S C x Q 111is iteral has been electronically signed and sealed by Nelson Blaulcenship, .Ir, on 10/19/18 using a digital signature. Printed copies of this do(AMMIt are not considered signed and sealed and the signature niust be verified on any electronic copies. Nelson Blatilcenship, A[A D4 7F] P-,w�® w s rn , U .0 z F� n DEMO O z 0 =FLOOR PLAN - ELECTRICAL SCALE: 1 /4 '=1'-0" GENERAL NOTES: A. DO NOT SCALE ELECTRICAL DRAWING FOR ANY DIMENSIONS. B. ALL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE, NATIONAL, STATE AND LOCAL CODES. PROVIDE GROUNDING AND BONDING PER NEC 250. C. SEE SINGLE LINE DIAGRAM FOR FEEDER WIRE AND CONDUIT SIZE. ALL CIRCUITS NOT SIZED ON DRAWING SHALL BE INSTALLED TO MEET MINIMUM SIZE REQUIRED BY NEC. ALL CONDUCTORS SHALL HAVE AN EQUIPMENT GROUND WIRE SIZED PER NEC. D. FIELD VERIFY EXACT LOCATION OF ALL DEVICES AND EQUIPMENT PRIOR TO ROUGH IN. E. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS AND ORIENTATIONS. F. REFER TO ARCHITECTURAL ELEVATIONS AND SECTIONS FOR ADDITIONAL LIGHTING FIXTURE MOUNTING DETAILS AND INFORMATION, G. ALL EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS SHALL BE CONNECTED "HOT" TO THE INDICATED LOCAL LIGHTING CIRCUIT, H. VERIFY ALL MOUNTING HEIGHTS AND PENDANT LENGTHS WITH ARCHITECT AND ENGINEER PRIOR TO ORDERING FIXTURES. I. EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A PERIOD OF 90 MINUTES IN THE EVENT OF FAILURE OF NORMAL LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOTCANDLE (10 LUX) AND A MINIMUM AT ANY POINT OF 0.1 FOOTCANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOTCANDLE (6 LUX) AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOTCANDLE (0.6 LUX) AT THE END OF THE EMERGENCY LIGHTING TIME DURATION, A MAXIMUM—TO—MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40:1 SHALL NOT BE EXCEEDED, J. ELECTRICAL ENERGY MONITORING: MEASUREMENT DEVICES (EMON DMON OR APPROVED SUBSTITUTION) SHALL BE INSTALLED IN NEW BUILDINGS TO MONITOR THE ELECTRICAL ENERGY OF THESE SYSTEMS (TOTAL ELECTRICAL ENERGY, HVAC SYSTEMS, INTERIOR LIGHTING, EXTERIOR LIGHTING AND RECEPTACLE CIRCUITS) PER ASHRAE 90.1 2013, SECTION 8.4.3.1. REFERENCE NOTES: O 0 CONNECT 120V RECEPTACLE CIRCUIT IN OFFICE SPACE VIA WATTSTOPPER PLUG LOAD POWER PACK #BZ -200 (OR APPROVED SUBSTITUTION) FOR AUTOMATIC CONTROL OF RECEPTACLES. RECEPTACLES SHALL BE SPLIT WIRED SO THAT THE POWER PACK SHALL AUTOMATICALLY "TURN OFF" THE TOP OUTLET ON EACH RECEPTACLE IF SPACE IS UNOCCUPIED FOR 20 MINUTES AND THE BOTTOM OUTLET SHALL BE CONSTANT HOT. OUTLETS SHALL BE VISUALLY MARKED AS REQUIRED TO DIFFERENTIATE CONTROLLED OUTLETS FROM UNCONTROLLED OUTLETS. RECEPTACLE POWER PACKS SHALL BE CONTROLLED VIA LOW VOLTAGE VACANCY SENSORS AS SHOWN ON LIGHTING PLAN, PROVIDE ALL CONDUIT AND LOW VOLTAGE WIRING AS REQUIRED TO INTERCONNECT RECEPTACLE POWER PACKS AND LIGHTING POWER PACKS. INSTALLATION SHALL COMPLY WITH FLORIDA BUILDING CODE SECTION C405.7.1, 2014 EDITION AND ASHRAE STANDARD 90.1. O PROVIDE CEILING MOUNTED, DUAL TECHNOLOGY, LOW VOLTAGE VACANCY SENSOR, WATTSTOPPER #DT -200 (OR APPROVED SUBSTITUTION) TO OVERRIDE WALL SWITCHES AND TURN OFF LIGHTS IF ROOM IS UNOCCUPIED FOR MORE THAN 30 MINUTES. COORDINATE LOCATION WITH CONDITIONS IN FIELD TO PROVIDE MAXIMUM COVERAGE OF SPACE. PROVIDE ADDITIONAL SENSORS, RELAYS, POWER PACKS, ETC. AS REQUIRED FOR COMPLETE COVERAGE OF SPACE. PROVIDE ALL CONDUIT AND LOW VOLTAGE WIRING AS REQUIRED TO INTERCONNECT LIGHTING POWER PACKS WITH RECEPTACLE POWER PACKS IN SPACE FOR AUTOMATIC CONTROL OF RECEPTACLES IF INDICATED ON POWER PLANS. INSTALLATION SHALL COMPLY WITH FLORIDA BUILDING CODE SECTION C405.7.1, 2014 EDITION. �3 PROVIDE WALL MOUNTED, DUAL TECHNOLOGY, LOW VOLTAGE VACANCY SENSOR, WATTSTOPPER #DW -100-24 (OR APPROVED SUBSTITUTION) FOR AUTOMATIC CONTROL OF LIGHTING. CONNECT LIGHTING IN SPACE AS SHOWN ON PLANS VIA WATTSTOPPER LIGHTING POWER PACK #BZ -200 (OR APPROVED SUBSTITUTION). PROVIDE ALL ADDITIONAL POWER PACKS, RELAYS, SENSORS AS REQUIRED FOR COMPLETE COVERAGE OF SPACE AND SWITCHING AS SHOWN ON PLANS. PROVIDE ALL CONDUIT AND LOW VOLTAGE WIRING AS REQUIRED TO INTERCONNECT LIGHTING POWER PACKS WITH RECEPTACLE POWER PACKS IN SPACE FOR AUTOMATIC CONTROL OF RECEPTACLES IF INDICATED ON POWER PLANS. INSTALLATION SHALL COMPLY WITH FLORIDA BUILDING CODE SECTION C405.7.1, 2014 EDITION. ® CONNECT EXISTING LIGHT FIXTURE TO NEW CIRCUITRY AND NEW LIGHTING CONTROLS AS SHOWN. 0 CONNECT NEW FIRE ALARM DEVICE TO EXISTING BUILDING FIRE ALARM SYSTEM. PROVIDE ALL SYSTEM UPGRADES, BATTERY UPGRADES, AND REPROGRAMMING AS REQUIRED. COORDINATE EXACT CONNECTION REQUIREMENTS WITH CONDITIONS IN FIELD AND MANUFACTURER'S RECOMMENDATIONS PRIOR TO ROUGH -IN AND PROVIDE AS REQUIRED. m 0 U D - �l cc 0 s o 3 IF o{ry�o r; a0 S C x Q 111is iteral has been electronically signed and sealed by Nelson Blaulcenship, .Ir, on 10/19/18 using a digital signature. Printed copies of this do(AMMIt are not considered signed and sealed and the signature niust be verified on any electronic copies. Nelson Blatilcenship, A[A P-,w�® w s rn , U .0 z F� n P4 C� + 4 rI �I ti 0 �I COOO 0 �1 DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1822 DRAWING NUMBER E-201 DATE 11-05-18 ELECTRICAL LOAD SUMMARY EXISTING ELECTRICAL LOAD REMOVED DURING DEMOLITION POWER 1.26 KVA LIGHTING 0.34 KVA NtW tLLUIKIUAL LUAU AUULU UUKING KtNOVAIIUN RECEPTACLES 2.34 KVA LIGHTING 0.70 KVA TOTAL ADDED 3.04 KVA NET TOTAL 0.99 KVA ADDED TO SERVICE EXISTING SERVICE IS ADEQUATE NN oe •, •'�,\CFN;S O °69060 A . ' r Q b,.d< G0 s��Nf1 Bla��►k���Gc�w��l�ddeth P.E. 669060 12 C O t2 U U U Q Q) O oN o t7 C a O .r_. •/1���M ��M1zN C QvrnV C �FF�v z ..0 i0 C 0 wF 0 a 'Chis iteut has been electronically sigued and sealed by Nelson Blaiiccnship, Jr. on 10/19/18 using a digital signature. Printed copies of this document are not considered sigued and sealed and the siguadure waist be verified on any eleeh'onie copies. Nelson Blankenship, AIA :. «, gas11 E-4 V4 Uri G 0 V ®.� U O �� Ct F oPH w I H Q .� � cu u DRAWN CHECKED MJWKCM BLS/AJB PROJECT NUMBER 1822 DRAWING NUMBER E-301 DATE 11-05-18 EXISTING PANEL'C' LOCATION: HALLWAY VOLTAGE: 208VI20V 30 4W MIN, AIC RATING: EXISTING NOTES: PROVIDE TYPED WRITTEN DIRECTORY PROVIDE GROUND & NEUTRAL BUS TYPE: EXISTING MAINS: 100A ®MLO ElMCB MOUNTING: SURFACE FED FROM: MDP LUGS: ❑ SUB -FEED ❑ FEED-THRU ENCLOSURE: NEMA 1 CIRCUIT DESCRIPTION o z BRANCH CIRCUIT BKR LOAD KVA PHASE 0 LOAD KVA BKR BRANCH CIRCUIT o CIRCUIT DESCRIPTION 0 NEUT GND COND 0 NEUT GND COND t SPARE EX EX EX EX 20/1 - A 0.54 20/1 EX EX EX EX RECEPT OFFICE 2 3 RECEPT COMPUTER RM EX EX EX EX 20/1 0.54 B 0.54 20/1 EX EX EX EX RECEPT OFFICE 4 5 COMPUTER RECEPT EX - - - 20/2 1.50 C 0.54 20/1 EX EX EX EX RECEPT BATH -CONFER. RM 6 7 - EX EX EX EX - 1.50 A 0.54 20/1 EX EX EX EX RECEPT CONFER RM 8 9 COMPUTER RECEPT EX - - - 20/2 1.50 B 0.90 20/1 12. 12 12 12 RECEPT TEACHING RM 10 11 - EX - - - - 1.50 C 0.72 20/1 12 12 12 12 RECEPT TEACHING RM 12 13 RECEPT GEN OFFICE EX EX EX EX 20/1 0.54 A 0.72 20/1 12 12 12 12 RECEPT TEACHING RM 14 15 RECEPT GEN OFFICE EX EX EX EX 20/1 0.54 B - 20/1 - - - - SPARE 16 17 SPARE OMIT EF 2 EX EX EX EX 20/1 0.50 C 0.50 20/1 EX EX EX I EX I jUPS 18 19 LTS TEACHING RM 12 12 12 12 20/1 0.56 A 0.50 20/1 EX EX EX EX EF BATHRMS 20 21 LTS WALK -WAY EX EX EX EX 20/1 1.00 B 1.50 20/1 EX EX EX EX DATA RACK (RT) 22 23 SALES SERVICE CUB. EX EXI EX EX 20/1 0.72 C 1.50 20/1 EX EX EX EX DATA RACK (LF) 24 25 SALES SERVICE CUB. EX EX EX EX 20/1 0.72 A - 20/1 - - - - 26 27 SALES CUB. EX EX EX EX 20/1 0.72 B - 20/1 - - - - 28 29 SALES CUB. EX EX EX EX 20/1 0.72 C - 20/1 - - - - - 30 EQUIPMENT SERVED CONN. LOAD L.F. D.F. DEMAND LOAD EXISTING LIGHTING 1.00 KVA 125% 1.25 KVA EXISTING EQUIPMENT AND RECEPTACLES 16.66 KVA 100% 16.66 KVA NEW LIGHTING 0.56 KVA 125% 0.70 KVA NEW RECEPTACLES 2.34 KVA 100% 2.34 KVA NOTES: TOTAL DEMAND LOAD: 20.95 KVA TOTAL DEMAND AMPS: 58.19 AMPS ELECTRICAL LOAD SUMMARY EXISTING ELECTRICAL LOAD REMOVED DURING DEMOLITION POWER 1.26 KVA LIGHTING 0.34 KVA NtW tLLUIKIUAL LUAU AUULU UUKING KtNOVAIIUN RECEPTACLES 2.34 KVA LIGHTING 0.70 KVA TOTAL ADDED 3.04 KVA NET TOTAL 0.99 KVA ADDED TO SERVICE EXISTING SERVICE IS ADEQUATE NN oe •, •'�,\CFN;S O °69060 A . ' r Q b,.d< G0 s��Nf1 Bla��►k���Gc�w��l�ddeth P.E. 669060 12 C O t2 U U U Q Q) O oN o t7 C a O .r_. •/1���M ��M1zN C QvrnV C �FF�v z ..0 i0 C 0 wF 0 a 'Chis iteut has been electronically sigued and sealed by Nelson Blaiiccnship, Jr. on 10/19/18 using a digital signature. Printed copies of this document are not considered sigued and sealed and the siguadure waist be verified on any eleeh'onie copies. Nelson Blankenship, AIA :. «, gas11 E-4 V4 Uri G 0 V ®.� U O �� Ct F oPH w I H Q .� � cu u DRAWN CHECKED MJWKCM BLS/AJB PROJECT NUMBER 1822 DRAWING NUMBER E-301 DATE 11-05-18 3' MINIMUM CEILING MOUNTED N,F.P.A, 72 -. 4" SMOKE DETECTOR CEILING z w A/C SUPPLY in � m DIFFUSER ACCEPTABLE HERE N z o NOT ACCEPTABLE HERE—/c% o AUDIO/VISUAL 0- m AND VISUAL AUDIO ONLYONLY DEVICES DEVICE FINISHED WALL SYNCHRONIZE MORE THAN TWO APPLIANCES IN ANY FIELD OF VIEW LU N.F.P.A. 72 a I? In J � o r- w `-` SIDE WALL o tL CL 0 N t -n- oa- r - Z o o m n- `- MANUAL o o PULL 0 R STATION (D Z Qi �R AQ CD0) o0 NOT TO 9 EXCEED 5'-0" R 4 FINISHED FLOOR 3 NTS SSS IFS System No, W -J-1020 C us F Rating — 2 Hr Classified by T Ratings — 0 and 114 Hr (See Item 3B) Underwriters Laboratories, Inc. to UL 1479 and CANIULC-s115 L Rating At Ambient — Less Than 1 CFM/Sq Ft L Rating At 400 F -- 4 CFM/Sq Ft SECTION A -A SECTION A -A �SS1pl% v C us Classified by underwriters Laboratories, Inc. to UL 1479 and CANULC•3116 MEN System No. W -L-1175 F Ratings -1 and 2 Hr (See Item 1) T Rating - 0 Hr L Rating at Ambient - Less Than 1 CFM/sq ft L Rating at 400 F - Less Than 1 CFM/sq ft 1. Wall Assembly— Min 5 in, thick reinforced lightweight or normal weight (100-150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks`. Max diam of opening is 8 in, See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Through Penetrants — One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The annular space between pipe, conduit or tubing and periphery of opening shall be min 3/4 in. to max 3-112 in. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Conduit — Nom 4 in. diam (or smaller) electrical metallic tubing or steel conduit. B. Copper Tubing Nom 4 in. diam (or smaller) Type L (or heavier) copper tubing. C. Copper Pipe - Nom 4 in. diam (or smaller) Regular (or heavier) copper pipe. 3. Firestop System The hourly F and T Rating for the firestop systems are dependent upon the type and size of pipe, annular space, fill material thickness and fill material type as described in the table below. When the annular space in the table shows a range of distances, the penetrating item may be installed either concentrically or eccentrically within the firestop system. The firestop systems shall consist of the following: A. Packing Material — Mineral wool batt insulation firmly packed into opening as a permanent form. As an option to the above, backer rod and/or foamed plastic backer material may be used. Packing material to be recessed from both surfaces of wall as required to accommodate the required thickness of fill material. B. Fill, Void or Cavity Material — Sealant' — Applied within the annulus, flush with both surfaces of wall as shown in the table below: Pipe Type Min Fill Mtl Thkns In. F Rating Hr. T Rating Hr. 2A 1/4 2 1/4 2B 1/2 2 0 'Bearing the UL Classification Mark 1 NTS UL FIRE RATED DETAIL (W -J-1020) 1. Wall Assembly — The 1 or 2 hr fire rated wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features. A. Studs — Wall framing shall consist of either wood studs or steel channel studs. Wood studs to consist of norn 2 by 4 in, lumber spaced 16 in. OC. Steel studs to be ruin 2-1/2 in. wide and spaced max 24 in. OC. B. Gypsum Board' — Norn 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the Fire Resistance Directory. Max diam of opening is 5-112 in. The hourly F and T Ratings of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrant — One metallic tubing or conduit installed concentrically or eccentrically within the firestop system. Tube or conduit to be rigidly supported on both sides of wall assembly. The annular space between the tube or conduit and periphery of the steel sleeve shall be min 0 in. (point contact) to max 1 in. The following types and sizes of metallic tube or conduit may be used: A. Conduit — Nom 4 in. diam (or smaller) steel electrical metallic tubing or steel conduit. 3. Fill Void or Cavity Material' — Putty — Min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. At point contact location between penetrant and wall, a 114 in. crown of fill material shall be applied at the conduit/wall interface on both sides of the assembly, lapping 1/4 in. on the conduit and 114 in. beyond the periphery of the opening. 'Bearing the UL Classification Mark 2 :), UL FIRE RATED DETAIL (W -L-1175) NTS ` `+Itilllilli// T " N�9y060 'A TTd �~ B��K� �v(ifi ��ce >2fdeth m c 0 CL U c� a� CE /moo a e 0 Cr 1E �1 ' •�,<ry c a�� ! V (]2N10 r� 0,nai vo So o This item has been electruuieally signed and sealed by Nelson 131aakenship, Jr. ua 10/19/18 using rr digital signature. fruited copies of this document 17re not considered signed raid sealed and lire sigaalure must be verified oa any electronic copies. Nelson Blankenship, AIA p� N - a 0 � �1 n 6 cn � w�1 S� CSI ^� cn � G/) N � DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1822 DRAWING NUMBER E-401 DATE 1-05-18 NERAL REQUIREMM A. DO ALL WORK IN COMPLIANCE. WITH THE LATEST ADOPTED EDITION OF THE FLORIDA BUILDING CODE (FOC -2017), NFPA 70 (NEC -2014) AND NFPA 101 (LIFE SAFETY CODE -2015), AND THE REGULATIONS OF THE LOCAL UTILITY TELEPHONE, CABLE TELEVISION AND POWER UTILITY COMPANIES. OBTAIN AND PAY FOR ANY AND ALL REQUIRED PERMITS, INSPECTIONS, CERTIFICATES OF INSPECTIONS AND APPROVAL, AND THE LIKE, AND DELIVER SUCH CERTIFICATES TO THE ENGINEER. B. THE CONTRACTOR SHALL FURNISH, PERFORM, OR OTHERWISE PROVIDE ALL LABOR (INCLUDING, BUT NOT LIMITED TO, ALL PLANNING, PURCHASING, PAINTING, TRANSPORTING, RIGGING, HOISTING, STORING, INSTALLING, TESTING, CHASING, CHANNELING, CUTTING, TRENCHING, EXCAVATING AND BACKFILLING), COORDINATION, FIELD VERIFICATION, EQUIPMENT INSTALLATION, SUPPORT; AND SAFETY, SUPPLIES, AND MATERIALS NECESSARY FOR THE CORRECT INSTALLATION OF COMPLETE AND FUNCTIONAL ELECTRICAL SYSTEMS (AS DESCRIBED OR IMPLIED BY THESE SPECIFICATIONS AND THE APPLICABLE DRAWINGS). C. ALL DRAWINGS AND SPECIFICATIONS ON THE PROJECT ARE COMPLEMENTARY, EACH TO ALL OTHER B SETS, AND THEY SHALL BE USED IN COMBINATION FOR THE EXECUTION OF THIS WORK. DIVISION 16 WORK SHOWN ON ANY ONE SET OF DRAWINGS, INCLUDING ALL ARCHITECTURAL DRAWINGS, MECHANICAL, PLUMBING AND FIRE PROTECTION DRAWINGS FOR GENERAL WORK AND EQUIPMENT, AND DIVISION 16 WORK CALLED FOR UNDER ANY SECTION OF THE PROJECT SPECIFICATIONS, SHALL BE CONSIDERED AS INCLUDED IN THIS WORK UNLESS SPECIFICALLY EXCLUDED BY INCLUSION IN SOME OTHER BRANCH OF THE WORK. THIS SHALL INCLUDE ROUGHING -IN FOR CONNECTIONS AND EQUIPMENT AS CALLED FOR OR INFERRED. THE CONTRACTOR SHALL CHECK ALL DRAWINGS AND SPECIFICATIONS FOR THE PROJECT AND SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL DIVISION 16 WORK. D. THE CONTRACTOR SHALL CAREFULLY CHECK THE DRAWINGS AND SPECIFICATIONS OF ALL OTHER TRADES AND DIVISIONS BEFORE INSTALLING ANY OF HIS WORK. HE SHALL IN ALL CASES CONSIDER THE WORK OF ALL OTHER TRADES, AND SHALL COORDINATE HIS WORK WITH THEM SO THAT THE BEST ARRANGEMENTS OF ALL EQUIPMENT, PIPING, CONDUIT, DUCTS, ROUGH -IN, ETC., CAN BE OBTAINED. E. LOCATIONS DESIGNATED FOR OUTLETS, SWITCHES, DEVICES, EQUIPMENT, ETC., ARE APPROXIMATE AND FINAL LOCATIONS SHALL BE VERIFIED IN THE FIELD. CONTRACTOR SHALL LOCATE ALL DEVICES UP TO 5 FEET IN ANY DIRECTION AS DIRECTED BY OWNER AND PER CODE. WHERE INSTRUCTIONS OR NOTES ARE INSUFFICIENT TO CONVEY THE INTENT OF THE DESIGN, CONSULT THE OWNER PRIOR TO BIDDING AND INSTALLATION. F. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING AND COORDINATING THE LOCATIONS OF DEVICES TO BE USED AND COORDINATING THE FINAL LOCATIONS OF ELECTRICAL EQUIPMENT WITH MILLWORK, SINKS, BENCHES, COUNTERS AND SHELVING PRIOR TO BIDDING AND INSTALLATION. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER. G. DIVISION 16 CONTRACTOR SHALL HAVE HAD EXPERIENCE OF AT LEAST THE SAME SIZE AND SCOPE AS THIS PROJECT, ON AT LEAST TWO OTHER PROJECTS WITHIN THE LAST FIVE YEARS IN ORDER TO BE QUALIFIED TO BID THIS PROJECT. H. CONTRACTOR SHALL AND DOES HEREBY WARRANT ALL MATERIALS AND EQUIPMENT FURNISHED UNDER THIS SECTION OF THE SPECIFICATIONS TO BE FREE FROM DEFECTS AND TO FUNCTION OR OPERATE SATISFACTORILY FOR ONE YEAR AFTER FINAL ACCEPTANCE OF THE WORK, AND THAT ANY ITEMS NOT MEETING THIS REQUIREMENT WILL BE MADE GOOD BY HIM WITHOUT COST TO OWNER, PROVIDED SUCH DEFECTS OR FAILURES ARE NOT DUE TO ABUSE, NEGLECT, OR LACK OF REASONABLE AND ORDINARY MAINTENANCE. I. ALL WORK SHALL BE EXECUTED IN A WORKMANSHIP MANNER DISPLAYING A NEAT MECHANICAL APPEARANCE UPON COMPLETION. J. BALANCE TOTAL PHASE LOADS IN EACH ELECTRICAL PANEL TO A VALUE WITHIN 10% OF EACH OTHER. K. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION, WHEREVER WORK IS TO BE PERFORMED IN FINISHED/OCCUPIED SPACES, TO PREVENT DAMAGE TO ADJACENT AREAS, EQUIPMENT, OR FURNISHINGS; TO PREVENT ACCIDENTAL INJURY TO BUILDING OCCUPANTS AND THE PUBLIC; TO PREVENT THE SPREADING OF DUST, DIRT, DEBRIS, AND MOISTURE FROM THE AREA WHERE WORK IS BEING PERFORMED; AND TO PREVENT DUST, DIRT, DEBRIS, AND MOISTURE FROM GETTING ON OR IN THE BUILDING OCCUPANT'S FURNISHINGS OR EQUIPMENT, L. THE CONTRACTOR SHALL REPAIR, AT NO COST TO THE OWNER, ANY DAMAGE DONE BY HIMSELF OR HIS EMPLOYEES. HE SHALL ALSO BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED TO PROPERLY INSTALL HIS WORK. THIS SHALL ALSO INCLUDE THE PATCHING OF EXISTING ROADWAYS (PAVED OR IMPROVED), PARKING AREAS, SIDEWALKS, WALLS, STAIRS, MECHANICAL WORK, CURBS, GUTTERS, ETC., CUT TO INSTALL WORK PROVIDED BY THE CONTRACTOR. PATCH WORK SHALL COMPLY WITH THE APPLICABLE SECTIONS OF THESE SPECIFICATIONS AND SHALL MATCH THE EXISTING FINISHES. M. UPON COMPLETION OF WORK, THE ENTIRE WIRING SYSTEM SHALL BE TESTED, AND SHALL BE SHOWN TO BE IN PROPER WORKING CONDITION IN ACCORDANCE WITH INTENT OF SPECIFICATIONS AND DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE ALL SYSTEMS READY FOR OPERATION AND TO HAVE AN ELECTRICIAN AVAILABLE TO OPERATE SAME IN ACCORDANCE WITH AND UNDER THE SUPERVISION OF THE INSPECTION REPRESENTATIVE OF THE ENGINEER. THE CONTRACTOR SHALL BE AVAILABLE TO ASSIST IN REMOVAL OF PANEL FRONTS, ETC., TO PERMIT INSPECTION AS .REQUIRED. N. IN ACCORDANCE WITH DIVISION 1 AND THE CONDITIONS OF THE CONTRACT, THE CONTRACTOR SHALL PROVIDE AND KEEP UP TO DATE A COMPLETE RECORD SET OF CONSTRUCTION "AS-BUILTS" BLUELINE PRINTS WHICH SHALL BE CORRECTED DAILY, AND SHALL SHOW EVERY CHANGE FROM THE ORIGINAL CONTRACT DRAWINGS, INCLUDING ADDENDA AND CHANGE ORDERS IN ACCORDANCE WITH GENERAL REQUIREMENTS AND SPECIAL CONDITIONS. 'THIS SET OF PRINTS SHALL BE KEPT ON THE JOB SITE, AND SHALL BE USED ONLY AS A RECORD SET. THIS SHALL NOT BE CONSTRUED AS AUTHORIZATION FOR THE CONTRACTORS TO MAKE CHANGES IN THE LAYOUT WITHOUT DEFINITE INSTRUCTION IN EACH CASE. II. ELECTRICAL SCOPE: A. FURNISHING AND INSTALLATION OF POWER SYSTEMS, AND AUXILIARY SYSTEMS AS SHOWN OR HEREIN SPECIFIED. B. CONNECTION OF ALL EQUIPMENT REQUIRING ELECTRICAL CONNECTION; MENTIONED IN THIS DIVISION OR SHOWN ON DRAWINGS, WHETHER FURNISHED BY DIVISION 16 OR UNDER OTHER DIVISIONS, OR FURNISHED BY OWNER. C. FURNISHING AND INSTALLATION OF OUTLET BOXES, CONDUIT RACEWAYS, FOR A TELEPHONE AND DATA RACEWAY DISTRIBUTION SYSTEM. (TELEPHONE AND DATA HARDWARE, AS WELL AS WIRING AND SOFTWARE IS NOT INCLUDED.) L D. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR CONTACTING THE OFFICES OF ALL LOCAL AND/OR STATE AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT IN .ORDER TO SCHEDULE ALL REQUIRED INSPECTIONS AND OBTAIN ALL NECESSARY PERMITS; ETC. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER OF ALL SCHEDULED INSPECTIONS AT LEAST TWO WEEKS IN ADVANCE OF THE SCHEDULED DATE. E. THE CONTRACTOR SHALL REPLACE ANY DEFECTIVE MATERIALS, EQUIPMENT, OR WORKMANSHIP WITHOUT COST TO THE OWNER WITHIN THE STIPULATED GUARANTEED PERIOD. F. IT SHALL BE THE RESPONSIBILITY OF THE DIVISION 16 CONTRACTOR TO HAVE ALL SYSTEMS READY FOR OPERATION AND TO HAVE AN ELECTRICIAN AVAILABLE FOR ALL INSPECTIONS. THE CONTRACTOR SHALL PROVIDE PERSONNEL TO ASSIST IN REMOVAL OF PANEL FRONTS, ETC. TO PERMIT INSPECTION AS REQUIRED. G. SUBMIT TO THE ARCHITECT/ENGINEER PROMPTLY AFTER AWARD OF CONTRACT AND PRIOR TO PURCHASING, SIX COPIES OF MANUFACTURER'S SHOP DRAWINGS IN ACCORDANCE WITH DIVISION 1, SECTION 01300 - SUBMITTALS FOR THE FOLLOWING ITEMS, ALL SHOP DRAWINGS OF A SPECIFIC ITEM OR SYSTEM SHALL BE MADE IN ONE SUBMITTAL AND WITHIN TEN DAYS AFTER AWARD OF CONTRACT. 1. PANELBOARDS 4. DISCONNECT SWITCHES 2. SUPPORTS 5. CONDUIT 3. WIRING DEVICES 6. WIRE H. COMPLETED WIRING SYSTEMS SHALL BE FREE FROM SHORT CIRCUITS AND AFTER COMPLETION, PERFORM TESTS FOR INSULATION RESISTANCE IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE. ALL WIRING SYSTEMS SHALL BE COMPLETELY AND TOTALLY "SAFED" DURING CONSTRUCTION, ONLY QUALIFIED PERSONNEL SHALL HANDLE ELECTRICAL SYSTEMS. I. BEFORE ROUGH -IN OF CIRCUITRY OR CONNECTING TO EQUIPMENT, FURNISHED UNDER THIS DIVISION, ANY OTHER DIVISION, OR BY THE OWNER, THE CONTRACTOR SHALL VERIFY THE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF THE EQUIPMENT BEING FURNISHED AND FOR THAT SPECIFIED AND SHOWN ON THE DRAWINGS AND PROVIDE FOR PROPER ROUGH -IN AND CONNECTION. J. THE ELECTRICAL CIRCUITS, COMPONENTS, AND CONTROLS FOR ALL EQUIPMENT ARE SELECTED AND SIZED, BASED ON THE EQUIPMENT SPECIFIED. IF SUBSTITUTIONS AND/OR EQUIVALENT EQUIPMENT ARE FURNISHED, IT SHALL BE THE RESPONSIBILITY OF ALL PARTIES CONCERNED, INVOLVED IN, AND FURNISHING THE SUBSTITUTE AND/OR EQUIVALENT EQUIPMENT TO VERIFY AND COMPARE THE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF THAT FURNISHED TO THAT SPECIFIED AND/OR SHOWN. IF GREATER CAPACITY OR MORE MATERIALS OR LABOR IS REQUIRED FOR THE ROUGH -IN, CIRCUITRY OR CONNECTIONS THAN FOR THE ITEM SPECIFIED AND PROVIDED FOR, THEN IT SHALL BE THE RESPONSIBILITY OF THE PARTIES INVOLVED IN PROVIDING THE SUBSTITUTE AND/OR EQUIVALENT. ITEMS OF EQUIPMENT TO PROVIDE ALL COMPENSATION FOR ADDITIONAL CHARGES MADE FOR THE PROPER ROUGH -IN,- CIRCUITRY AND CONNECTIONS FOR THE EQUIPMENT FURNISHED. NO ADDITIONAL CHARGES ABOVE THE BASE BID SHALL BE ALLOWED FOR SUCH REVISIONS. K. EXCAVATION FOR UNDERGROUND ELECTRICAL STRUCTURES: CONFORM TO ELEVATIONS AND DIMENSIONS SHOWN WITHIN A TOLERANCE OF PLUS OR MINUS 0.10'; PLUS A SUFFICIENT DISTANCE TO PERMIT PLACING AND REMOVAL OF CONCRETE FORMWORK, INSTALLATION OF SERVICES, OTHER CONSTRUCTION, AND FOR INSPECTION. L. TRENCHING: EXCAVATE TRENCHES FOR ELECTRICAL INSTALLATIONS AS FOLLOWS: 1. EXCAVATE TRENCHES TO THE UNIFORM WIDTH, SUFFICIENTLY WIDE TO PROVIDE AMPLE WORKING ROOM AND A MINIMUM OF 6" TO 9" CLEARANCE ON BOTH SIDES OF RACEWAYS AND EQUIPMENT. 2. EXCAVATE TRENCHES TO DEPTH INDICATED OR REQUIRED. CAN BE MADE AND G CINSTALLATIONS 3. LIMIT THE LENGTH OF OPEN TRENCH TO THAT IN WHICH THE TRENCH BACKFILLED WITHIN THE SAME DAY. 4. WHERE ROCK IS ENCOUNTERED, CARRY EXCAVATION BELOW REQUIRED ELEVATION AND BACKFILL WITH A LAYER OF CRUSHED STONE OR GRAVEL PRIOR TO INSTALLATION OF RACEWAYS AND EQUIPMENT. PROVIDE A MINIMUM OF 6" OF STONE OR GRAVEL CUSHION BETWEEN ROCK BEARING SURFACE AND ELECTRICAL INSTALLATIONS. M. THE CONTRACTOR SHALL PROVIDE ALL INSERTS FOR THE SUPPORT OF DIVISION 16 EQUIPMENT TO BE PLACED IN CONCRETE OR THROUGH CONCRETE SLABS AS CONSTRUCTION PROGRESSES. HE SHALL PROVIDE ALL MISCELLANEOUS HANGING AND SUPPORTING HARDWARE. ALL ELECTRICAL WORK IS TO BE CONCEALED IN OR BUILT INTO GENERAL CONSTRUCTION SHALL BE PLACED AS CONSTRUCTION PROGRESSES. FAILURE OF THE CONTRACTOR TO COORDINATE WORK WITH OTHER TRADES AND THE PROJECT CONSTRUCTION PROGRESS SHALL MAKE HIM RESPONSIBLE FOR ALL COST OF CUTTING AND PATCHING, AS REQUIRED TO INSTALL WORK. NO STRUCTURAL MEMBER, MASONRY CONSTRUCTION OR FINISHED WORK SHALL BE CUT OR ALTERED WITHOUT PRIOR WRITTEN APPROVAL BY THE ARCHITECT/ENGINEER. CONTRACTOR SHALL FIRE RATE ALL PENETRATIONS THROUGH ALL FIRE RATED SLABS OR WALLS PER 'THE INTENDED RATING. N. THE CONTRACTOR SHALL SUPPLY AND SET INTO PLACE ALL WALL SLEEVES FOR CONDUITS AND CEILING INSERTS FOR HANGERS IN AREAS OF NEW CONSTRUCTION AS BUILDING CONSTRUCTION PROGRESSES. INSTALL EQUIPMENT NOTED TO BE CONCEALED IN WALLS BEFORE WALLS ARE CONSTRUCTED IN ORDER THAT WALLS MAY BE CONSTRUCTED AROUND CONDUITS, ENCLOSURES, ETC, 0. METALLIC MATERIALS SHALL BE PROTECTED AGAINST CORROSION. EQUIPMENT ENCLOSURES SHALL BE GIVEN RUST -INHIBITING TREATMENT AND STANDARD FINISH BY MANUFACTURER. ALUMINUM SHALL NOT BE USED ON CONTACT WITH EARTH, AND, WHERE CONNECTED TO DISSIMILAR METAL, SHALL BE PROTECTED BY SUITABLE FITTINGS AND TREATMENT. ALL FERROUS METALS SUCH AS ANCHORS, BOLTS, BRACES, BOXES, BODIES, CLAMPS, FITTINGS, GUARDS, NUTS, PINS, RODS, SHIMS, THIMBLES, WASHERS, AND MISCELLANEOUS PARTS, NOT OF STAINLESS STEEL OR NONFERROUS MATERIALS, SHALL BE HOT -DIPPED GALVANIZED. P. ALL CONDUITS STUBBED OUT FOR FUTURE USE SHALL HAVE A PULL WIRE INSTALLED, A PLASTIC CAP INSTALLED AND BE IDENTIFIED AS TO THE CONDUIT ORIGIN. Q. THE RESPONSIBILITY FOR ANY CUTTING OF CONSTRUCTION WHICH IS REQUIRED FOR THE INSTALLATION OF DIVISION 16 WORK, SHALL BE BY THE CONTRACTOR. THE CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES AND THE OWNER BEFORE ANY CUTTING AND OBTAIN APPROVAL FROM THE ARCHITECT/ENGINEER PRIOR TO ANY CUTTING. ALL PATCHING AND FINISHING SHALL BE BY THE CONTRACTOR. R. WHERE OPENINGS OR HOLES ARE CUT IN CONSTRUCTION AND THE CUTTING BREAKS ELECTRICAL CIRCUITRY OR CONTROL CIRCUITRY CONDUIT AND WIRING, THEN IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REROUTE THE CIRCUITRY CONDUIT AND REWIRING AND TO COMPLETE THE CIRCUITRY AS REQUIRED AND AS APPROVED BY THE ARCHITECT/ENGINEER. TEMPORARY COMPLETION SHALL BE PROVIDED WHERE NECESSARY BEFORE THE PERMANENT REROUTING AND COMPLETION WORK IS FINISHED. S. ANY PENETRATIONS OF FIRE OR SMOKE RATED ASSEMBLIES MADE BY THIS CONTRACTOR IN VERTICAL OR HORIZONTAL CONSTRUCTION SHALL BE SEALED AND PROTECTED BY THIS CONTRACTOR IN ORDER TO MAINTAIN THE ESTABLISHED FIRE RATING WITH METHODS AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. III. IDENTIFICATION: A. IDENTIFICATION NAMEPLATES SHALL BE LAMINATED PLASTIC, SECURED TO EQUIPMENT WITH TWO SCREWS. B. EACH PANELBOARD AND SWITCHBOARD SHALL BE EQUIPPED WITH A PERMANENT PLASTIC NAMEPLATE WITH 1/2" MINIMUM LETTERS, SECURELY FASTENED TO THE DEVICE. C. EACH INDIVIDUALLY MOUNTED CIRCUIT BREAKER, SWITCH, TRANSFER SWITCH, MOTOR STARTER, LIGHTING CONTACTOR, TRANSFORMER AND/OR ANY OTHER CONTROL OR PROTECTIVE DEVICE INCLUDING EQUIPMENT DISCONNECT SWITCHES SHALL BE EQUIPPED WITH A PERMANENT PLASTIC NAMEPLATE WITH 1/2" MINIMUM LETTERS. D. PANELBOARDS SHALL HAVE TYPEWRITTEN DIRECTORIES. ALL CIRCUITS TO BE IDENTIFIED BY DEVICES SERVED AND ROOM NUMBERS (I.E., LIGHTING ROOM 216). HANDWRITTEN DIRECTORIES WILL NOT BE ALLOWED. E. EACH JUNCTION BOX CABINET OR WIREWAY LARGER THAN 6" X 6" SHALL BE EQUIPPED WITH A PLASTIC NAMEPLATE WITH 1/2" MINIMUM LETTERS INDICATING THE SYSTEM ENCLOSED. F. ALL SYSTEMS JUNCTION BOXES AND CONDUIT SHALL BE COLOR CODED INSIDE AND OUTSIDE OF THE BOX PRIOR TO THE INSTALLATION OF CONDUCTORS PER THE FOLLOWING: 1. CCN SYSTEM: GREEN 2. TELEPHONE DATA SYSTEM: BLUE 3. FIRE ALARM SYSTEM: RED G. ENTIRE BOX INSIDE AND OUT, INCLUDING COVER, SHALL BE PAINTED PRIOR TO INSTALLING CONDUCTORS. IV, WIRING DEVICES: A. SWITCHES AND RECEPTACLES IN LOBBIES, CORRIDORS OR COMMERCIAL SPACES, UNFINISHED AND MECHANICAL SPACES SHALL BE 20 AMP COMMERCIAL GRADE 125 VAC. GRAY IN COLOR WITH STAINLESS STEEL COVERPLATES. B. WEATHERPROOF RECEPTACLES SHALL BE GFCI TYPES WITH GASKETED STAINLESS STEEL KEY LOCKABLE FLIP COVER TYPE COVERPLATES. SURGE SUPPRESSION TYPE OUTLETS IN MDFS AND IDFS SHALL BE HUBBELL #83625 (BLUE) OR EQUAL. C. RECEPTACLES PROVIDED FOR ATTACHMENT OF CORD AND PLUG EQUIPMENT SHALL BE HEAVY DUTY, SPECIFICATION GRADE, NON -INTERCHANGEABLE, FLUSH MOUNTED TYPES OF THE PROPER NEMA CONFIGURATION TO SERVE THE EQUIPMENT. NEMA CONFIGURATIONS SHALL BE VERIFIED PRIOR TO INSTALLATION OF CIRCUIT CONDUCTORS. CONTRACTOR TO PROVIDE ALL CONNECTION, WIRING, PIGTAILS FOR DISHWASHERS, COOKING RANGES, OVENS AND GARBAGE DISPOSALS. D. ALL DEVICES SHALL HAVE PROPER PLATES, CARPET FLANGES, TRIMS, RINGS, ESCUTCHEONS, ETC., AS MANUFACTURED BY SAME MANUFACTURER AS DEVICES. ANY TELEPHONE OR OTHER OUTLET WHICH IS NOT EQUIPPED WITH A PLATE FURNISHED BY OTHERS SHALL HAVE ONE PROVIDED BY THIS CONTRACTOR, DEVICE PLATES SHALL BE COLOR AND TYPE AS SHOWN BELOW. 1. FINISHED SPACES DECORA LINE: a. IVORY DEVICES b. IVORY NYLON PLATES 2. UNFINISHED OR INDUSTRIAL OR COMMERCIAL TYPE SPACES: a. GRAY DEVICES b. STAINLESS STEEL OR STAMPED GALVANIZED STEEL ON SURFACE MOUNTED BOXES c. STAINLESS STEEL PLATES ON FLUSH MOUNTED BOXES ELECTRICAL SPECIFICATIONS F. MOUNTING HEIGHTS ARE APPROXIMATE. THE EXACT LOCATIONS AND MOUNTING HEIGHTS SHALL BE DETERMINED ON THE JOB AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH ALL TRADES TO INSURE CORRECT INSTALLATION, I.E., OVER COUNTERS IN OR ABOVE BACK -SPLASHES, IN BLOCK WALLS, TILE, AND OTHER SPECIFIC CONSTRUCTION FEATURES, LOCATION OF OUTLETS MOUNTED IN BUILT-INS, MILLWORK, AND CABINETRY SHALL BE VERIFIED. OUTLETS MOUNTED IN KICK OR TOE SPACES SHALL BE MOUNTED HORIZONTALLY. OUTLET BOXES SHALL BE MOUNTED TO PREVENT DEVICE PLATE FROM OVERLAPPING BACKSPLASH, TRIM, TILE, ETC. LOCATE SO DEVICE PLATE WILL LAY FLAT AGAINST SURFACE COMPLETELY AROUND THE PERIMETER OF PLATE. G. OUTLETS, OTHER THAN THOSE COORDINATED WITH COUNTER TOPS, SHELVES, AND CABINETS, SHALL BE LOCATED WITH THE CENTER LINE OF OUTLET BOXES THE FOLLOWING DISTANCE ABOVE THE FINISHED FLOOR, UNLESS OTHERWISE INDICATED: 1. RECEPTACLES, GENERAL: 1'-6" AFF 2. TELEPHONE OUTLETS: 1'-6" AFF 3. SWITCHES, GENERAL: 4'-0" AFF V. RACEWAYS A. SHALL BE GALVANIZED OUTSIDE AND INSIDE BY HOT DIPPING. E.M.T. SHALL BE ELECTRO- GALVANIZED. CONDUITS SHALL BE AS MANUFACTURED BY REPUBLIC, PITTSBURGH STANDARD, WHEATLAND, TRIANGLE, ALLIED, OR YOUNGSTOWN. B. SHALL BE STANDARD THREADED TYPE, GALVANIZED OUTSIDE AND INSIDE BY HOT DIPPING. THREADLESS AND CLAMP TYPE NOT ACCEPTABLE. SHALL BE AS MANUFACTURED BY RACO, EFCOR, OR APPLETON. C. SHALL BE STEEL THREADED COMPRESSION TYPE. ALL COUPLINGS AND CONNECTORS SHALL BE EFCOR OR RACO. PRESSURE INDENTED TYPE CONNECTORS OR CAST METAL WILL NOT BE APPROVED FOR ANY LOCATION. D. CONNECTORS SHALL HAVE PLASTIC INSULATED THROAT INSERTS. E. THE USE OF METAL CLAD CABLE IS ACCEPTABLE IN LOCATIONS AS ACCEPTED BY THE NEC AND ALL LOCAL JURISDICTIONAL CODES. F. STEEL METAL CLAD CABLE, TYPE MC, EMPLOYING CIRCUIT CONDUCTORS #12 SOLID TO #2 AWG, SOLID OR STRANDED COPPER WITH THHN INSULATION, AN INSULATED GREEN GROUNDING CONDUCTOR AND GALVANIZED STEEL INTERLOCKED ARMOR CLADDING. THE CABLES SHALL BE SUITABLE FOR USE IN DRY LOCATIONS AT TEMPERATURES NOT EXCEEDING 90' C ON AD CIRCUITS UP TO 600 VOLTS IN ACCORDANCE WITH N.E.C., ARTICLE 334. THE CABLE SHALL BE ONE AND TWO HOUR FIRE RATED PER ANSI/UL 1479 FOR USE IN WALL, CEILING AND FLOOR ASSEMBLIES. G. FLEXIBLE METALLIC CONDUIT RACEWAYS MAY BE USED TO CONNECT HVAC UNITS LOCATED IN INTERIOR MECHANICAL AREAS. MINIMUM SIZE 3/4". H. CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE LATEST NATIONAL ELECTRICAL CODE EXCEPT THAT NO CONDUIT SHALL BE SMALLER THAN 3/4" UNLESS OTHERWISE NOTED. CONDUIT SHALL BE SIZED LARGER THAN REQUIRED ABOVE WHEN SO SHOWN ON THE DRAWINGS OR WHEN REQUIRED BY LOCAL CODE. I. ANY CONDUIT STUBBED OUT FOR FUTURE SHALL BE CAPPED WITH A PLASTIC CAP AND MARKED WITH A 2" MINIMUM RED METAL TAG WHICH IDENTIFIES CONDUIT ORIGIN. CONDUITS STUBBED UP ABOVE GRADE OR ROOF SHALL BE TAGGED ON THE CONDUIT. CONDUIT STUBBED OUT BELOW GRADE SHALL BE TAGGED ON NEAREST BUILDING WALL, CURB, ETC., DIRECTLY OVER THE CONDUIT RUN. ALL EMPTY CONDUITS SHALL HAVE PULL WIRES. A. SCHEDULE, 40 RIGID PVC: A. CONDUIT SHALL BE COMPOSED OF POLYVINYLCHLORIDE AND SHALL BE UL RATED TYPE 40 FOR USE WITH 90EC RATED CONDUCTORS. CONDUIT SHALL CONFORM TO NEMA STANDARDS AND APPLICABLE SECTIONS OF NEC. B. INSTALLATION OF RIGID NON-METALLIC CONDUIT SHALL COMPLY WITH ARTICLE 347 OF THE NATIONAL ELECTRICAL CODE (NFPA 70) AND THESE SPECIFICATIONS, C. PROVIDE A CONTINUOUS, INSULATED, GROUNDING CONDUCTOR IN EVERY RIGID, NON-METALLIC RACEWAY EVEN IF NOT SHOWN ON THE DRAWINGS. THE GROUNDING CONDUCTOR SHALL BE CONNECTED TO GROUND AT EACH END OF THE RACEWAY IN ACCORDANCE WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE (NFPA 70). D. WHERE RIGID NON-METALLIC CONDUIT TRANSITIONS TO METALLIC CONDUIT, THE LOCATION OF THE TRANSITION SHALL BE UNDERGROUND. E. NO PVC CONDUIT SHALL BE RUN EXPOSED, OR ABOVE GRADE. VII WIRE AND CABLE 600 VOLT: A. CONDUCTORS SHALL HAVE CURRENT CARRYING CAPACITIES AS PER NEC AND WITH 600 VOLT INSULATION, #12 AVERAGE MINIMUM FOR 20 AMP CIRCUITS AND #14 FOR 15 AMP CIRCUITS EXCEPT FOR CONTROLS, AND FIXTURE WIRE. CONDUCTORS SHALL BE COPPER. B. #12 AND #10 SHALL BE SOLID, TYPE THW/THWN INSULATION. C. #8 AND LARGER, AND ANY SIZE TO MOTORS SHALL BE STRANDED TYPE THW. D. SHALL BE MADE WITH T & B STA-KON WIRE JOINTS, PT SERIES, COMPLETE WITH INSULATING CAPS AND INSTALLED WITH WT161 TOOL OR WT2000 TOOL, IDEAL SUPER -NUTS (NOT WIRE NUTS), IDEAL WING NUTS, OR BUCHANAN ELEC. PRODUCTS B CAP OR SERIES 2000 PRES- SURE CONNECTORS COMPLETE WITH NYLON SNAP-ON INSULATORS AND INSTALLED WITH C24 PRESSURE TOOL. E. ALL JOINTS AND SPLICES IN WIRE SHALL BE MADE WITH APPROVED SOLDERLESS CONNECTORS, AND COVERED SO THAT INSULATION IS OWNER APPROVED EQUAL TO CONDUCTOR INSULATION. SPLICES SHALL NOT BE PERMITTED IN CONTROL, SECURITY, FIRE ALARM, TELEVISION OR COMMUNICATIONS SYSTEMS, OR WHERE OTHERWISE NOTED. SPLICING OF WIRE OR CABLES WILL NOT BE ALLOWED BELOW GRADE, INCLUDING IN BOXES BELOW GRADE. F. BOTH CONDUCTORS AND CONDUITS SHALL BE CONTINUOUS FROM OUTLET TO OUTLET. G. IN INSTALLING THE MAIN ELECTRICAL SERVICE, ADDITIONAL SLACK CONDUCTORS SHALL BE PROVIDED AND TERMINATED AS REQUIRED BY ELECTRIC UTILITY FOR CONNECTION TO THEIR EQUIPMENT. FIELD COORDINATE WITH UTILITY PRIOR TO INSTALLING CONDUCTORS. H. IN INSTALLING PARALLEL CONDUCTORS IT IS MANDATORY THAT ALL CONDUCTORS MAKING UP THE FEEDER BE EXACTLY THE SAME LENGTH, THE SAME SIZE AND THE SAME TYPE OF CONDUCTOR WITHTHESA E INSOLATION. FURTHER, EACHGROUPOF CONDUCTORS MAKINGING UP A PHASE OR NEUTRAL MUST BE BONDED AT BOTH ENDS IN AN APPROVED MANNER. I. CONDUCTOR SIZES INDICATED ON CIRCUIT HOMERUNS OR IN PANELBOARD SCHEDULES SHALL BE INSTALLED OVER THE ENTIRE LENGTH OF THE CIRCUIT UNLESS NOTED OTHERWISE ON THE DRAWINGS. J. CONDUCTORS SHALL BE CONTINUOUS AND UNSPLICED WHERE INSTALLED IN CONDUIT. SPLICES SHALL OCCUR ONLY WITHIN WIRING TROUGHS, WIREWAYS, JUNCTION BOXES, OUTLET BOXES, OR EQUIPMENT ENCLOSURES WHERE SUFFICIENT ADDITIONAL ROOM IS PROVIDED FOR ALL SPLICES. K. EACH BRANCH CIRCUIT AND FEEDER CONDUCTOR SHALL BE COLOR CODED. FOR CONDUCTOR SIZES THRU NO. 6 AWG, THE INSULATION SHALL BE OF THE COLOR AS INDICATED BELOW. COLOR CODE SHALL BE STRICTLY ADHERED TO. FOR CONDUCTOR SIZES NO. 4 AWG AND LARGER, COLOR CODED PHASE TAPE MAY BE APPLIED COMPLETELY AROUND THE CONDUCTOR INSULATION WITHIN 8" OF EACH END OF THE CONDUCTOR AND IN EACH PULL OR JUNCTION BOX OR WHENEVER CONDUCTORS ARE PHYSICALLY EXPOSED TO VIEW. GROUNDING CONDUCTORS AND GROUNDED CONDUCTORS SHALL HAVE INSULATION COLOR AS INDICATED FOR SIZES THROUGH #6 AWG. 120/208 V, 3PHASE4W PHASE A, COLOR: BLACK PHASE B, COLOR: RED PHASE C, COLOR: BLUE NEUTRAL, COLOR: WHITE GROUND, COLOR: GREEN VIII. GROUNDING: A. THIS SECTION DEALS WITH THE GROUNDING OF SERVICE EQUIPMENT, TRANSFORMERS, NON- CURRENT CARRYING CONDUCTIVE SURFACES OF EQUIPMENT, METAL BUILDING, STRUCTURES AND OTHER EQUIPMENT. B. ALL GROUNDING CONNECTIONS SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES AND REQUIREMENTS, SUCH CODES SHALL BE CONSIDERED MINIMUM REQUIREMENTS AND THE INSTALLATION OF THE GROUNDING SYSTEM SHALL INSURE FREEDOM FROM DANGEROUS SHOCK EXPOSURE AND SHALL PROVIDE A LOW IMPEDANCE GROUND FAULT PATH TO PERMIT OPERATION OF OVERCURRENT AND GROUND FAULT PROTECTIVE DEVICES. C. ALL SERVICE AND EQUIPMENT GROUNDING CONDUCTORS, AND BONDING JUMPERS SHALL BE INSULATED COPPER, TYPE THHN, THWN, OR THW CONDUCTORS (UNLESS NOTED OTHERWISE) AND SHALL BE SIZED IN ACCORDANCE WITH THE APPLICABLE PORTIONS OF ARTICLES 250 AND 517 OF THE NATIONAL ELECTRICAL CODE. GROUNDING CONDUCTORS #6 AWG AND SMALLER SHALL HAVE A GREEN COLOR INSULATION. ALL GROUNDING CONDUCTORS #4 AWG AND LARGER SHALL BE ADEQUATELY IDENTIFIED WITH A GREEN TRACER AND/OR GREEN COLORED TAPE AT EACH END OF THE GROUNDING CONDUCTOR AND AT EACH PULLBOX OR OTHER ACCESSIBLE LOCATION. D. THE MAIN SERVICE GROUNDING ELECTRODE SYSTEM SHALL CONSIST OF THE FOLLOWING ITEMS BONDED TOGETHER BY THE GROUNDING ELECTRODE CONDUCTORS IN ACCORDANCE WITH NEC ARTICLE 250, PART H: 1. THE MAIN UNDERGROUND COLD WATER PIPE, IF METAL, NEC 250- 81(A) 2. METAL FRAME OF BUILDING WHERE AVAILABLE, NEC 250-81(8) 3. CONCRETE ENCASED ELECTRODE, NEC 250-81(C) 4. THE BUILDING LIGHTNING PROTECTION SYSTEM, E. THE NEUTRAL CONDUCTOR SHALL BE GROUNDED AT THE SERVICE ENTRANCE MAIN DISCONNECT, AND AT EACH SEPARATELY DERIVED SYSTEM ONLY PER NEC ARTICLE 250. F. A #6 (MINIMUM) INSULATED COPPER CONDUCTOR INSTALLED IN 3/4" CONCEALED CONDUIT SHALL BE CONNECTED FROM THE BUILDING GROUNDING ELECTRODE SYSTEM TO EACH BUILDING TELEPHONE TERMINAL/DATA IDF TERMINAL BOARDS, OR CABINETS, FIRE ALARM CONTROL CABINETS, CCN SYSTEM CABINETS, EMS CABINETS, AND SECURITY SYSTEM CABINETS, TERMINATE ON AN APPROPRIATELY SIZED (8) TERMINAL MULTI -CONDUCTOR CONNECTION GROUNDING LUG LOCATED WITHIN CABINET OR ON TERMINAL BOARDS. 7:1►C01-.I/7:L A. PANELBOARDS SHALL BE DEAD FRONT TYPE AND SHALL BE IN ACCORDANCE WITH UNDERWRITERS' LABORATORIES, INC„ STANDARD FOR PANELBOARDS AND ENCLOSING CABINETS AND SO LABELED. B. PANELBOARDS SHALL BE FACTORY ASSEMBLED WITH BRANCH BREAKERS ARRANGED AS SHOWN IN SCHEDULES. BREAKERS SHALL BE NUMBERED VERTICALLY BEGINNING TOP LEFT. BREAKER NUMBERS SHALL BE PERMANENTLY ATTACHED TO TRIM. PANEL SHALL BE MINIMUM 20" WIDE OR 16" FOR RESIDENTIAL LOAD CENTERS, UNLESS SPECIFICALLY NOTED OTHERWISE. C. ANY SPECIAL REQUIREMENTS ON THE DRAWINGS OR SCHEDULES, SUCH AS GROUND FAULT PROTECTION, ARC -FAULT CIRCUIT BREAKERS, INCREASED INTERRUPTING CAPACITY, SHUNT TRIP TYPE CIRCUIT BREAKER, FEED THRU PANELBOARDS, ETC., SHALL SUPERSEDE THESE SPECIFICATIONS, BUT ONLY INSOFAR AS THAT PARTICULAR REQUIREMENT IS CONCERNED AND AS INDICATED. D. WIRING IN PANELBOARD GUTTERS SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. WIRING SHALL BE GROUPED INTO NEAT BUNDLES AND SECURED WITH NYLON TIE WRAPS. E. PROVIDE TYPE WRITTEN DIRECTORIES FOR EACH PANELBOARD INDICATING THE LOAD SERVED. X. LIGHTING FIXTURES: A. LIGHTING FIXTURES SHALL BE FURNISHED AS SHOWN ON DRAWINGS AND IN THE LIGHTING FIXTURE SCHEDULE. IT SHALL SPECIFICALLY BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXACT TYPE CEILING AND RECESSING DEPTH OF ALL RECESSED FIXTURES AND TO FURNISH THE MOUNTING TRIMS AND ACCESSORIES OF THE SPECIFIED AND/OR APPROVED FIXTURES FOR THE CEILING TO BE INSTALLED. LIGHTING FIXTURES SHALL BE PROVIDED WITH JOINER PLATES, END CAPS, RETAINING CLIPS, PLASTER FRAMES, HOUSINGS, AND ALL OTHER ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION. B. ALL FIXTURES SHALL BE EQUIPPED WITH LAMPS UNLESS OTHERWISE NOTED. LAMPS SHALL BE INSTALLED NEW, IMMEDIATELY PRIOR TO FINAL INSPECTION, AND SHALL NOT BE USED FOR CONSTRUCTION. C. FIXTURE CATALOG NUMBER REPRESENTS BASIC LUMINARY SIZE, TYPE, QUALITY AND CONFIGURATION. ACCESSORIES SHALL BE FURNISHED WITH EACH UNIT AS REQUIRED FOR A COMPLETE FINISHED INSTALLATION. BASIC ACCESSORIES SHALL INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: 1. JOINING PLATES, END CAPS, RETAINING CLIPS, ETC. 2. TRIMS FOR RECESSED FIXTURES. 3. FIXTURE STEMS AND CANOPIES FINISHED TO MATCH FIXTURES. 4. SPECIAL MOUNTING BRACKETS, TENONS, SLIP FILTERS, CONCRETE BASES, POLES, ANCHOR BOLTS, JUNCTION BOXES, AND STANCHIONS FOR ALL EXTERIOR LIGHTING FIXTURES. PROVIDE ALL WEATHERPROOFING FOR ALL LIGHTING FIXTURES TO BE INSTALLED IN EXTERIOR LOCATIONS. D. STRUCTURAL SUPPORT OF ALL FIXTURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. E. THE SYSTEM GROUNDING CONDUCTOR SHALL BE SECURED TO EACH FIXTURE BODY BY MEANS 0F A BONDING SCREW. F. OWNER/DEVELOPER WILL HAVE RIGHT TO RELOCATE LIGHTING FIXTURES OR LIGHTING SWITCHES WITHIN 72" OF LOCATION SHOWN ON FIRST WALK-THROUGH AT NO ADDITIONAL EXPENSE. COORDINATE THE WALK-THROUGH PRIOR TO THE INSTALLATION OF THE WIRING. XI. FIRE ALARM SYSTEMS A. THIS SECTION INCLUDES AUTOMATIC ADDRESSABLE VOICE EVACUATION FIRE ALARM SYSTEMS, INCLUDING FIRE ALARM CONTROL PANEL, AND REMOTE ANNUNCIATOR, MANUAL PULL STATIONS, HEAT AND SMOKE DETECTORS, FIRE ALARM AUDIO, VISUAL SIGNAL EQUIPMENT, CONTROLS, AND SURGE PROTECTION DEVICES. COORDINATE ALL WIRING AND DEVICE INTERFACES WITH OWNER'S REPRESENTATIVE. THE FIRE ALARM SYSTEM SHALL MEET THE LATEST ADOPTED EDITION OF NFPA 72 WITH ALL LOCAL AND STATE AMENDMENTS AND FEDERAL ADA REQUIREMENTS. ALL DEVICES SHALL BE WHITE IN COLOR WITH RED LETTERING. B. GENERAL: COMPLETE, ZONED, NONCODED, ADDRESSABLE, MICROPROCESSOR -BASED FIRE DETECTION ALARM SYSTEM WITH MANUAL AND AUTOMATIC ALARM INITIATION SIGNALS FROM A SUPERVISED FIRE ALARM SOUND DISTRIBUTION SYSTEM. DEVICES LOCATED OUTDOORS SHALL BE SPECIFICALLY DESIGNED FOR EXTERIOR SERVICE. PROVIDE BATTERY BACK-UP BASED UPON TOTAL LOAD PER NFPA 72. ALARM SHALL ACHIEVE A MINIMUM OF 80 DB THROUGHOUT OCCUPIABLE SPACES AND MEET ADA REQUIREMENTS. 0 C. TRANSMISSION TO REMOTE CENTRAL STATION: PROVIDE WIRING TO AUTOMATICALLY R UTE AN ALARM, SUPERVISORY, AND TROUBLE SIGNALS TO THE GRAND SANDESTIN CENTRAL STATION SERVICE TRANSMITTER LOCATED IN MAIN FIRE ALARM CONTROL PANEL USING LISTED AND APPROVED EQUIPMENT. PROVIDE ALL NECESSARY WIRING CONNECTION BY THIS CONTRACTOR. D. GENERAL ALARM: A SYSTEM GENERAL ALARM INCLUDES: 1. INDICATING THE GENERAL ALARM CONDITION AT THE FACP AND THE INTEGRAL ANNUNCIATOR. 2. IDENTIFYING THE DEVICE THAT IS THE SOURCE OF THE ALARM AT THE FACP AND THE ANNUNCIATOR, 3. INITIATING AUDIBLE AND VISIBLE ALARM SIGNALS THROUGHOUT THE BUILDING. 4. STOPPING HVAC SUPPLY AND RETURN FANS, 5. INITIATING TRANSMISSION OF ALARM SIGNAL TO REMOTE CENTRAL STATION. 6. MANUAL STATION ALARM OPERATION INITIATES A GENERAL ALARM, 7. SMOKE OR HEAT DETECTION INITIATES A GENERAL ALARM. E. INSTALLER QUALIFICATIONS: A CERTIFIED FACTORY -TRAINED TECHNICIAN IS TO PERFORM THE WORK OF THIS SECTION, MAKING UP ALL TERMINAL CABINETS, INSTALLING ALL SURGE SUPPRESSORS, AND INCLUDING LANDING AND TESTING EACH WIRE, MOUNTING AND CONNECTING ALL DEVICES, PROGRAMMING THE MAIN FACP, TROUBLE SHOOTING AND CERTIFYING THE FINAL SYSTEM. THE CONTRACTOR SHALL BE CURRENTLY LICENSED BY THE STATE OF FLORIDA FOR FIRE ALARM WORK, AND SHALL BE A CERTIFIED FACTORY -TRAINED TECHNICIAN, CONTRACTOR IS RESPONSIBLE FOR OBTAINING NECESSARY FIRE ALARM PERMITS FROM AUTHORITY HAVING JURISDICTION. F. FIRE ALARM DEVICES AND EQUIPMENT TO BE INSTALLED OUTDOORS IN EXTERIOR LOCATIONS SHALL BE SPECIFICALLY DESIGNED AND U.L. LISTED AS WEATHER AND WATERPROOF. PROVIDE WEATHERPROOF NEOPRENE GASKETS BETWEEN WALL MOUNTING SURFACE AND FIRE ALARM DEVICE FOR ALL DEVICES MOUNTED OUTDOORS. G. AVAILABLE MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS. ALL DEVICES SHALL BE PROVIDED FOR AND MANUFACTURED BY SIMPLEX, EST, NOTIFIER, OR PYROTRONICS. H. DESCRIPTION; DOUBLE -ACTION NON -BREAK GLASS, ADDRESSABLE TYPE, FABRICATED OF METAL OR PLASTIC, AND FINISHED IN WHITE WITH MOLDED, RAISED -LETTER OPERATING INSTRUCTIONS OF RED COLOR. ADDRESS OF UNIT SHALL BE FIELD-SETTABLE WITHOUT SPECIAL TOOLS. I. INITIATION CIRCUITS (LOOP): INITIATION LOOP CONDUCTORS SHALL BE WEST PENN #D991 FOR 3000'-0" IN LENGTH AND LESS. WEST PENN #D995 SHALL BE USED FOR CIRCUITS OVER 3000'-0" IN LENGTH. BELOW GRADE, WET OR DAMP LOCATION INSTALLED CABLE, INCLUDING CABLE INSTALLED ON THE TOP OF EXTERIOR WALKWAYS, SHALL BE WEST PENN AQUASEAL MULTI -CONDUCTOR (14 GAUGE), UNLESS NOTED OTHERWISE, SHALL BE INSTALLED IN CONDUIT. J. SIGNAL CIRCUITS: SIGNAL CIRCUITS SHALL BE #12 AWG THWN 19 STRAND COPPER. K. ANNUNCIATOR CIRCUITS: #12 AWG THWN 19 STRAND COPPER. L. EACH AND EVERY WIRE SHALL BE LABELED AT EACH END WITH SLC #, CHANNEL # OR SIGNAL #. EACH SEPARATE CIRCUIT, INITIATION, SIGNAL AND AUXILIARY SHALL HAVE A SPECIFIC NUMBER, LABEL EACH CONDUCTOR BY THIS CIRCUIT NUMBER AT THE CONTROL CONNECTIONS AND AT EACH TERMINAL CONNECTION IN THE TERMINAL CABINETS. M. PROVIDE COMPLETE SIGNAL, SPEAKER DATA LOOP AND POWER SIDE SURGE SUPPRESSION MODULES ON ALL WIRING ENTERING OR LEAVING EACH BUILDING. THE CONTRACTOR SHALL REPAIR ANY DAMAGED COMPONENTS OR WIRING DUE TO TRANSIENT VOLTAGE SURGES FOR A PERIOD OF ONE YEAR FROM SUBSTANTIAL COMPLETION DATE AT NO ADDITIONAL COST. N. PROVIDE RELAYS FOR OTHER LOCAL CONTROL SUCH AS HVAC SHUTDOWN AND/OR STAIR PRESSURIZATION FAN INITIATION, ROLL -UP DOOR ACTIVATION, FIRE/SMOKE DAMPER RELEASE OR SMOKE EVACUATION INITIATION, RELAYS SHALL BE 10 AMP RATED RELAYS. UPON ACTIVATION OF THE FIRE ALARM SYSTEM, THE RELAY SHALL ACTIVATE AND SHUTDOWN THE CONTROLLED EQUIPMENT. LOCATE ALL RELAYS WITHIN 36" OF EQUIPMENT CONTROLLED. PROVIDE WEATHERPROOF UNITS WHERE INDICATED OR INSTALL IN WEATHERPROOF BOXES. 0. PROVIDE REMOTE AUDIO/VISUAL POWER SUPPLY AND BATTERY CHARGER IN A SELF-CONTAINED LOCKABLE CABINET: PROVIDE (4) STYLE Y NOTIFICATION CIRCUITS, AND AN INTEGRAL BATTERY CHARGER. PROVIDE UNIT WITH INTEGRAL 120 VOLT INPUT A/C POWER AND INTEGRAL LEAD ACID BATTERY. PROVIDE SURGE SUPPRESSION FOR 120 VOLT BRANCH CIRCUIT AND PROVIDE A 20 AMP 125 VAC SPECIFICATION GRADE KEY TYPE SWITCH TO CONTROL THE POWER TO THE SIGNAL EXPANDER FOR MAINTENANCE. IDENTIFY THE 120 VOLT CIRCUIT SERVING THE SWITCH (I.E. PANELBOARD AND BRANCH CIRCUIT NUMBER). P. PROVIDE A FLUSH MOUNTED LCD REMOTE ANNUNCIATOR. UNIT SHALL BE NO LARGER THAN 12" TALL X 16" LONG, AND SHALL BE COMPLETELY FLUSH MOUNTED IN THE MAIN LOBBY OF THE FACILITY. Q. INSTALLATION: CONTRACTOR SHALL PROVIDE ALL CONDUIT, WIRING RELAYS, CONTROLS AND ASSOCIATED DEVICES AND DETECTORS FOR PHASE I AND PHASE II RECALL PER FLORIDA BUILDING CODE (FBC) REQUIREMENTS AND STATE ELEVATOR INSPECTOR REQUIREMENTS. R. WIRING METHOD: INSTALL WIRING IN METAL RACEWAY. CONCEAL RACEWAY EXCEPT IN UNFINISHED SPACES AND AS INDICATED. S. NO FIRE ALARM CONDUCTORS SHALL BE INSTALLED BELOW GRADE WITH THE EXCEPTION OF CONDUCTORS ROUTED FROM BUILDING TO BUILDING, AS NOTED, OR WHERE ABSOLUTELY NECESSARY AND WITH PRIOR WRITTEN PERMISSION OF THE OWNER AND ENGINEER. ALL OTHER WIRING SHALL BE OVERHEAD INSTALLED IN CONCEALED CONDUIT MINIMUM 1/2". NO UNDERGROUND, ON GROUND OR UNDERGROUND SPLICES IN PULL BOXES WILL BE ALLOWED, T. MOUNTING BOXES FOR SPEAKERS/HORN/STROBES, CONTROL AND MONITOR MODULES SHALL BE INSTALLED IN DEEP JUNCTION BOXES WITH EXTENSION RING ATTACHED. U. MINIMUM SYSTEM TESTS: TEST THE SYSTEM ACCORDING TO THE PROCEDURES OUTLINED IN NFPA 72. MINIMUM REQUIRED TESTS ARE AS FOLLOWS: 1. VERIFY THE ABSENCE OF UNWANTED VOLTAGES BETWEEN CIRCUIT CONDUCTORS AND GROUND. 2. MEGGER TEST ALL CONDUCTORS OTHER THAN THOSE INTENTIONALLY AND PERMANENTLY GROUNDED WITH ELECTRONIC COMPONENTS DISCONNECTED. TEST FOR RESISTANCE TO GROUND. REPORT READINGS OF LESS THAN 1 -MEGOHM FOR EVALUATION. 3. TEST ALL CONDUCTORS FOR SHORT CIRCUITS UTILIZING AN INSULATION -TESTING DEVICE. 4. WITH EACH CIRCUIT PAIR, SHORT CIRCUIT AT THE FAR END OF THE CIRCUIT AND MEASURE THE CIRCUIT RESISTANCE WITH AN OHMMETER, RECORD THE CIRCUIT RESISTANCE OF EACH CIRCUIT ON THE RECORD DRAWINGS. 5. VERIFY THE CONTROL UNIT IS IN THE NORMAL CONDITION AS DETAILED IN THE MANUFACTURER'S OPERATING AND MAINTENANCE MANUAL. 6. TEST INITIATING AND INDICATING CIRCUITS FOR PROPER SIGNAL TRANSMISSION UNDER OPEN CIRCUIT CONDITIONS. ONE CONNECTION EACH SHOULD BE OPENED AT NOT LESS THAN 10 PERCENT OF THE INITIATING AND INDICATING DEVICES. OBSERVE PROPER SIGNAL TRANSMISSION ACCORDING TO CLASS OF WIRING USED, 7. TEST EACH INITIATING AND INDICATING DEVICE FOR ALARM OPERATION AND PROPER RESPONSE AT THE CONTROL UNIT. TEST SMOKE DETECTORS WITH ACTUAL PRODUCTS OF COMBUSTION. 8. TEST THE SYSTEM FOR ALL SPECIFIED FUNCTIONS ACCORDING TO THE MANUFACTURER's OPERATING AND MAINTENANCE MANUAL. SYSTEMATICALLY INITIATE SPECIFIED FUNCTIONAL PERFORMANCE ITEMS AT EACH STATION INCLUDING MAKING ALL POSSIBLE ALARM AND MONITORING INITIATIONS AND USING ALL COMMUNICATIONS OPTIONS. FOR EACH ITEM, OBSERVE RELATED PERFORMANCE AT ALL DEVICES REQUIRED TO BE AFFECTED BY THE ITEM UNDER ALL SYSTEM SEQUENCES. OBSERVE INDICATING LIGHTS, DISPLAYS, SIGNAL TONES, AND ANNUNCIATOR INDICATIONS. OBSERVE ALL VOICE AUDIO FOR ROUTING, CLARITY, QUALITY, FREEDOM FROM NOISE AND DISTORTION, AND PROPER VOLUME LEVEL. 9. TEST BOTH PRIMARY POWER AND SECONDARY POWER. VERIFY, BY TEST, THE SECONDARY POWER SYSTEM IS CAPABLE OF OPERATING THE SYSTEM FOR THE PERIOD AND IN THE MANNER SPECIFIED. V. OCCUPANCY ADJUSTMENTS: WHEN REQUESTED WITHIN ONE YEAR OF DATE OF SUBSTANTIAL COMPLETION, PROVIDE ON-SITE ASSISTANCE IN ADJUSTING SOUND LEVELS AND ADJUSTING CONTROLS AND SENSITIVITIES TO SUIT ACTUAL OCCUPIED CONDITIONS. PROVIDE UP TO FIVE PREPAID VISITS TO THE SITE FOR THIS PURPOSE. W. PROVIDE THE SERVICES OF A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO DEMONSTRATE THE SYSTEM AND TRAIN OWNER'S MAINTENANCE PERSONNEL AS SPECIFIED BELOW: 1. TRAIN OWNER'S MAINTENANCE PERSONNEL IN THE LOCATION OF DEVICES, BOXES, PROCEDURES AND SCHEDULES INVOLVED IN OPERATING, TROUBLESHOOTING, SERVICING, AND PREVENTIVE MAINTAINING OF THE SYSTEM. PROVIDE A MINIMUM OF 4 HOURS TRAINING. TRAINING INCLUDE SHALL H IN A COMPLETE PROJECT WALKDOWN WITH OWNER's AUTHORIZED REPRESENTATIVE TO IDENTIFY DEVICE LOCATIONS, JUNCTION BOX LOCATIONS AND SURG SUPPRESE ULE LOCA SIGN MOD TIONS. 2. SCHEDULE TRAINING WITH THE OWNER AT LEAST SEVEN WORKING DAYS IN ADVANCE. m c 0 0 .Y 0 U) (D 0 Q) 0 (D i O N 06 � o T, -f 0 v � j �ovoO o C Q N 00 6 .��`V = .Lr- zo 0- 0m .q ^` a This item has been electronically signed and sealed by Nelson Blankenship, Jr. on 10/19/18 using a digital signature. Printed copies of this clocuateut are not considered signed and settled tmd the signature must be verified on any electronic copies. Nelson Blankenship, AIA 1 �I .�L� 11 i � ,t�° Ill e W, a � n I�4 •, Is V U �t a r/, cn u r � �! a H® _t 0 J 0 O M ® � ;Q o ate `I9 0 pq ti ;' ��, cl� V •r� CJ ;4 , cc) u c ^ W O Qt w 0 V" 1i 2 f� I O 4 C/)o [� °' w C/) � A 0 �� .� 4.4 rte+ u '�' ct �' o U m T • �l � .6.� u DRAWN I CHECKED MJR/KCM I BLS/AJB PROJECT NUMBER 1822 DRAWING NUMBER E-501 DATE I -US -18 , , ,