HomeMy WebLinkAbout1000 Oak Ave 18-3413- NEW BUILDING-SHED0 D 0. M A. STRUCTURAL WORK SHALL. BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, (oTH EDITION (2011), AS ADOPTED AND SUPPLEMENTED BY LOCAL REGULATIONS. B. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS AT THE 51TE AND SHALL. NOTIFY THE ENGINEER OF DISCREPANCIES BETWEEN THE ACTUAL CONDITIONS AND INFORMATION SHOWN ON THE DRAWINGS BEFORE PROCEEDING WITH THE WORK. C. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE COMPLETE DESIGN OF THE STRUCTURE. THEY DO NOT INDICATE THE METHODS OF CONSTRUCTION UNLESS SD STATED OR NOTED. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE WORKMEN OR OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR EARTH BANKS, FORMS, SCAFFOLDINGc, PLANKING, SAFETY NETS, SUPPORT AND BRACING FOR CRANES AND GIN POLES. D. THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACING AND SHORING OF ALL STRUCTURAL MEMBERS AS REQUIRED FOR STRUCTURAL STABILITY OF THE STRUCTURE DURING ALL PHASES OF CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY CONDITION WHICH, IN HIS OPINION, MIGHT ENDANGER THE STABILITY OF THE STRUCTURE OR CAUSE D16TRE65 IN THE STRUCTURE. E, CONSTRUCTION MATERIALS SHALL NOT BE STACKED ON FLOORS OR ROOFS IN EXCESS OF THE DESIGN LIVE LOADS WHICH ARE INDICATED IN THE GENERAL NOTES. IT 15 THE GENERAL CONTRACTOR'S RESPONSIE31LITY TO INSURE THAT THE SUBCONTRACTORS ARE INFORMED AND DO NOT VIOLATE THIS IMPORTANT REQUIREMENT. IMPACT SHALL BY AVOIDED WHEN PLACING MATERIALS ON FLOORS OR ROOFS. F. PLANS, SECTIONS AND DETAILS ARE NOT TO BE SCALED FOR DETERMINATION OF QUANTITIES, LENGTHS OR FIT OF MATERIALS. G. FOR ACTUAL ELEVATION OF FIRST FLOOR EL. 100'-0', SEE SITE PLAN. H. SUBMIT WRITTEN REQUEST TO THE ENGINEER FOR APPROVAL OF ANY PROPOSED CHANGE TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. SPLICING, CUTTING, NOTCHING OR OTHER ALTERATIONS TO STRUCTURAL MEMBERS ARE NOT PERMITTED WITHOUT WRITTEN AUTHORIZATION OF THE STRUCTURAL ENGINEER. ANY UNAUTHORIZED DEVIATION FROM THE CONTRACT DOCUMENTS, AND CORRECTION THEREOF, IS THE RESPONSIBILITY OF THE CONTRACTOR. 1=555�IC'14�" A. DESIGN DATA 1. ROOF DEAD LOAD .......... 20 PSF 2. ROOF LIVE LOAD ...... 1. 20 PSF B. WIND LOADS THIS STRUCTURE HAS BEEN DESIGNED FOR WIND LOADS IN ACCORDANCE WITH CHAPTER 16 OF THE FLORIDA BUILDING CODE, 6TH EDITION (2010 AND A5CE-1 AS FOLLOWS: RISK CATEGORY . I ........ CATEGORY II ULTIMATE DESIGN WIND SPEED .......... 140 MPH (3 -SECOND GUST) NOMINAL DESIGN WIND SPEED .......... 108 MPH EXPOSURE CATEGORY C BUILDING CLA551FICATICN ENCLOSED INT. PRESSURE COEFF. (+/-) 0.18 THIS STRUCTURE (RISK CATEGORY II AND LANDWARD OF THE COUNTOUR LINE) 15 NOT IN THE WIND-BORNE DEBRIS REGION C. NOMINAL DE61GN WIND PRESSURES (COMPONENTS AND CLADDING): a 1. A = 6'-1" A-< >-A H = 15'_ 7 " 2. PRESSURES SHOWN ARE APPLIED NORMAL TO THE SURFACE. 3, PLUS AND MINUS SIGNS SIGNIFY PRESSURE ACTING TOWARDS AND AWAY FROM THE SURFACES, RESPECTIVELY. 4. FOR EFFECTIVE WIND AREAS BETWEEN THOSE GIVEN, VALUE MAY ISE INTERPOLATED, OTHERWISE USE THE VALUE ASSOCIATED WITH THE LOWER EFFECTIVE WIND AREA. WOOD RRAMNG A. ALL 50LID SAWN (55) FRAMING LUMBER TO BE AS FOLLOWS-. I. RAFTERS/JOISTS. . . ...... ............................. STP 12, UN.O. B ALL SHEATHING TO BE AS FOLLOWS: L ALL SHEATHING TO BE APA OR TECO RATED. 2. ALL ROOF/FLOOR SHEATHING TO BE ORIENTED PERPENDICULAR TO SUPPORTS. 3. NOMINAL PANEL THICKNESSES SPECIFIED ON PLAN TO BE AS FOLLOWS: a. 1/16' .421' THICKNESS - 24/0 SPAN RATING b. 15/32' - .469" THICKNESS - 24/16 SPAN RATING c. 19/32' - 594" THICKNESS - 32/16 SPAN RATING d. 23/32 ° - _119" THICKINESS - 48/24 SPAN RATING C. ALL ATTACHMENTS SHALL BE AS INDICATED IN FBG TABLE 2304.9.1, U.N.O. D. METAL CONNECTORS TO BE PROVIDED BY SIMPSON STRONG -TIE. REFER TO SIMPSON WOOD CONSTRUCTION CONNECTORS CATALOG (CURRENT EDITION) FOR ADDITIONAL, INFORMATION. ALTERNATE CONNECTORS WITH EQUIVALENT OR HIGHER LOADS MAY BE USED IN LIEU OF SPECIFIED COMPONENTS. E. ALL NAILS SHALL BE "COMMON", U.N.O. NAIL SIZES TO BE AS FOLLOWS: 1. 8d - .131" x 2 1/2" 2. 10d - .148" x 3" 3. 12d - .148" x 3 1/4' 4. IroD - .162" x 3 1/2" F_ ALL LUMBER SPECIFIED ON DRAWINGS ARE INTENDED FOR DRY USE ONLY (MOISTURE CONTENT OF 19% OR LESS), U.N.D. ALL WATERPROOFING AND FIRE SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE DESIGNED AND DETAILED BY OTHERS. G. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH OR CONCRETE SHALL BE PRESSURE TREATED. UNTREATED WOOD SHALL. NOT BE IN DIRECT CONTACT WITH CONCRETE OR MASONRY. SEAT PLATES TO BE PROVIDED AT ALL SEARING LOCATIONS WITHOUT WOODEN TOP PLATES. MIL I T I TM A. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS AT THE SITE, INCLUDING, BUT NOT LIMITED TO, EX15TING PIPES, UTILITIES, POWER LINES, ETC., AND SHALL NOTIFY THE OWNER OF DISCREPANCIES BETWEEN THE ACTUAL CONDITIONS AND INFORMATION SHOWN ON THE DRAWINGS, BEFORE PROCEEDING WITH THE WORK. EATH INATTAC 1 1 T A. PLYWOOD ROOF SHEATHING ROOF DECK SHALL BE 19/32" EXPOSURE 1, C -D PLYWOOD. ALL END JOINTS SHALL BE STAGGERED 1/2 PANEL LENGTH IN ALTERNATING ROWS, LONG DIMENSION SHALL BE PERPENDICULAR TO FRAMING. FASTENERS FOR THE ROOF SHEATHING SHALL. BE AS FOLLOWS: ZONE 1: MIN. Sd RING SHANK 6' D.G. ALONG EDGES, BLOCKING AND FIELD ZONE 2: MIN. 8d RING SHANK 6' O.C, ALONG EDGES, BLOCKING AND FIELD ZONE 3: MIN. Sd RING SHANK 4" O.G. ALONG EDGES, 5L.00KING AND 6' D.C. FIELD NOTE: USE 10d RING SHANK NAILS EDGES, BLOCKING AND SUPPORTS AT SPACING ABOVE WHEN 19/32" ROOF SHEATHING IS USED. 4 FT_ U 1 I- _ _ - - _ - - - _.._. __._ - __.__ - _.__ - ..,_Z-71 a T -4 HT_ 4 FT_ 2 r- - - - - - - - - - - - - ® __ 4 FT. 0 4 FT.l H IND5X OF DESIGN WIND PRESSURES (PSF): COMPONENTS AND CLADDING FOR NOMINAL WIND SPEED (ASD) a EFFECTIVE AISC ROOF WALLS AREA (5F) ZONE I ZONE 2 ZONE 3 ZONE 4 ZONE 5 0 TO 19.99 12.0/ -31.4 12.8 / -52.1 12.8 / -52.1 20.1/ -31.1 20.1/ -38,3 20 TO 49.99 12.0/,30.6 12.0/-411 12.0/-41.1 21.4/-29_S 21.4/-35.6 50 TO 99.99 10.9 / -295 10.9 / -39.6 10.9 / -39fo 25.8 / -28.2 25.8 / -32.5 100 AND OVE 10.1 / -28.-i 10J / -34.0 10.1 / -34.0 24.5 / -26.9 24.5 WOOD RRAMNG A. ALL 50LID SAWN (55) FRAMING LUMBER TO BE AS FOLLOWS-. I. RAFTERS/JOISTS. . . ...... ............................. STP 12, UN.O. B ALL SHEATHING TO BE AS FOLLOWS: L ALL SHEATHING TO BE APA OR TECO RATED. 2. ALL ROOF/FLOOR SHEATHING TO BE ORIENTED PERPENDICULAR TO SUPPORTS. 3. NOMINAL PANEL THICKNESSES SPECIFIED ON PLAN TO BE AS FOLLOWS: a. 1/16' .421' THICKNESS - 24/0 SPAN RATING b. 15/32' - .469" THICKNESS - 24/16 SPAN RATING c. 19/32' - 594" THICKNESS - 32/16 SPAN RATING d. 23/32 ° - _119" THICKINESS - 48/24 SPAN RATING C. ALL ATTACHMENTS SHALL BE AS INDICATED IN FBG TABLE 2304.9.1, U.N.O. D. METAL CONNECTORS TO BE PROVIDED BY SIMPSON STRONG -TIE. REFER TO SIMPSON WOOD CONSTRUCTION CONNECTORS CATALOG (CURRENT EDITION) FOR ADDITIONAL, INFORMATION. ALTERNATE CONNECTORS WITH EQUIVALENT OR HIGHER LOADS MAY BE USED IN LIEU OF SPECIFIED COMPONENTS. E. ALL NAILS SHALL BE "COMMON", U.N.O. NAIL SIZES TO BE AS FOLLOWS: 1. 8d - .131" x 2 1/2" 2. 10d - .148" x 3" 3. 12d - .148" x 3 1/4' 4. IroD - .162" x 3 1/2" F_ ALL LUMBER SPECIFIED ON DRAWINGS ARE INTENDED FOR DRY USE ONLY (MOISTURE CONTENT OF 19% OR LESS), U.N.D. ALL WATERPROOFING AND FIRE SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE DESIGNED AND DETAILED BY OTHERS. G. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH OR CONCRETE SHALL BE PRESSURE TREATED. UNTREATED WOOD SHALL. NOT BE IN DIRECT CONTACT WITH CONCRETE OR MASONRY. SEAT PLATES TO BE PROVIDED AT ALL SEARING LOCATIONS WITHOUT WOODEN TOP PLATES. MIL I T I TM A. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS AT THE SITE, INCLUDING, BUT NOT LIMITED TO, EX15TING PIPES, UTILITIES, POWER LINES, ETC., AND SHALL NOTIFY THE OWNER OF DISCREPANCIES BETWEEN THE ACTUAL CONDITIONS AND INFORMATION SHOWN ON THE DRAWINGS, BEFORE PROCEEDING WITH THE WORK. EATH INATTAC 1 1 T A. PLYWOOD ROOF SHEATHING ROOF DECK SHALL BE 19/32" EXPOSURE 1, C -D PLYWOOD. ALL END JOINTS SHALL BE STAGGERED 1/2 PANEL LENGTH IN ALTERNATING ROWS, LONG DIMENSION SHALL BE PERPENDICULAR TO FRAMING. FASTENERS FOR THE ROOF SHEATHING SHALL. BE AS FOLLOWS: ZONE 1: MIN. Sd RING SHANK 6' D.G. ALONG EDGES, BLOCKING AND FIELD ZONE 2: MIN. 8d RING SHANK 6' O.C, ALONG EDGES, BLOCKING AND FIELD ZONE 3: MIN. Sd RING SHANK 4" O.G. ALONG EDGES, 5L.00KING AND 6' D.C. FIELD NOTE: USE 10d RING SHANK NAILS EDGES, BLOCKING AND SUPPORTS AT SPACING ABOVE WHEN 19/32" ROOF SHEATHING IS USED. 4 FT_ U 1 I- _ _ - - _ - - - _.._. __._ - __.__ - _.__ - ..,_Z-71 a T -4 HT_ 4 FT_ 2 r- - - - - - - - - - - - - ® __ 4 FT. 0 4 FT.l H IND5X OF STRUCTURAL !:)RALUINaS a AMERICAN CONCRETE INSTITUTE AISC } FR CONSTRUCTION to PAGE SHEET ALTERNATE/ALTERNATIVE TITLE W- 1 S-l.l G.C. GENERAL STRUCTURAL NOTES AWS 1 5 2.1 BOTTOM OF PLAN AND DETAILS BOND BEAM A_B_ ANCHOR BOL.T5 ACI AMERICAN CONCRETE INSTITUTE AISC AMERICAN INSTITUTE OF STEEL FR CONSTRUCTION 4I5I AMERICAN IRON AND STEEL INSTITUTE ALT ALTERNATE/ALTERNATIVE ARCH. ARCHITECTURE/ARCHITECTURAL ASTM AMERICAN SOCIETY FOR TESTING AND G.C. MATERIALS AWS AMERICAN WELDING SOCIETY B/ BOTTOM OF BB BOND BEAM BLDG BUILDING BLK BLOCK BM BEAM 51 BASE PLATE/BEARING PLATE BRG BEARING BTJ BOLTED TIE JOIST CANT CANTILEVER CP CONCRETE BEAM CG CONCRETE COLUMN CJ CONTRACTION JOINT/CONTROL JOINT CL CENTERLINE CMU CONCRETE MASONRY UNIT GL -R. CLEAR/CLEARANCE COL COLUMN CONC. CONCRETE CONNX CONNECTION CONST CONSTRUCTION CSJ CONSTRUCTION JOINT DEPT DEPARTMENT PET. DETAIL DFT DRY FILM THICKNESS DIA. DIAMETER DIM DIMENSION DIST DISTANCE DN DOWN DR DRAIN DWG DRAWING EA. EACH EE EACH END EF EACH FACE EL ELEVATION EMB EMBEDMENT ENGR ENGINEER E05 EDGE OF SLAB EW EACH WAY EXIST. EXISTING EXT_ EXTERIOR F.D. FLOOR DRAIN FF FINISH FLOOR FLR FLOOR FR FIRE RETARDANT FTG FOOTING F.V. FIELD VERIFY GA. GAGE/GAUGE GALV. GALVANIZED G.C. GENERAL CONTRACTOR GLU-LAM GLUE -LAMINATED 6N_ GENERAL NOTES N.A.S. HEADED ANCHOR STUDS HORIZ. HORIZONTAL. HSS HOLLOW STRUCTURAL SECTIONS HT, HEIGHT INT. INTERIOR JST JOIST JT JOINT LDH LONG DIMENSION HORIZONTAL LDV LONG DIMENSION VERTICAL LGTH LENGTH LLH LONG LEG HORIZONTAL. L.LV LONG LEG VERTICAL LSL LONG -SLOTTED l MANUF. MANUFACTURE/MANUFACTURER MATL MATERIAL MAX. MAXIMUM MB MASONRY BEAM MD METAL DECK MECH. MECHANICAL MEZZ MEZZANINE MIN. MINIMUM MISC. MISCELLANEOUS MO MASONRY OPENING MTL METAL N.I.G. NOT IN CONTRACT NOM NOMINAL N.T.S. NOT TO SCALE N.W.T. NORMAL WEIGHT TOPPING O_C_ ON CENTER OPNG OPENING OPP. OPPOSITE PGC PRE -CAST CONCRETE PEMB PRE-ENGINEERED METAL BUILDING PL PLATE PLY. PLYWOOD PRE -ENG PRE-ENGINEERED PREFAI5 PREFABRICATED Pi�'OJ PROJECTION PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED PW PANEL WIDTH RCP REINFORCED CONCRETE PIPE R.A. ROOF DRAIN REF REFERENCE REINF REINFORCING READ. REQUIRED RW RETAINING WALL SA STUD ANCHOR SCHED SCHEDULE SF STEPPED FOOTING SIM, SIMILAR SPC SPACE/SPACES SPECS SPECIFICATIONS SQ. SQUARE 55 STAINLESS STEEL SSL SHORT -SLOTTED STD STANDARD 5TL STEEL STRUCT. STRUCTURAL SYM SYMMETRICAL T/ TOP OF T AND B TOP AND BOTTOM T 4 G TONGUE AND GROOVE TE3 TIE BEAM TND THREAD/THREADED THK THICK TS TUBE STEEL TYP. TYPICAL UN -0. UNLESS NOTED OTHERWISE VERT. VERTICAL VOL VOLUME W WIDE FLANGE W/ WITH W/O WITHOUT WD WOOD WF WALL FOOTING WH WEEP HOLE WP WATERPROOF W.P. WORKING POINT W.W.F. WELDED WIRE FABRIC RECORD COPY REVIEWED FOR CODE COMPLIANCE PL, EXAMINER DATE AUO 0 9 201 u L i A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOIAT E, CAN(,' EL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OFA PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERROR$ IN PLANS, CONSTRUCTION OR VIOLATIONS OF TFIIS CODE JAN!`"O[L) HISTORIC PERMIT All work must be done nt ntricr accordwee with the Approved Con, ,crate cif Appropriaten6s !:Building docs not appri r ,:, r, work oatsWa this scope Permit Applicant it; sotey responsible for compliance w �xF Awa. 42� V� C �o ywE-� 13 a w;a 'c 4E W 0 VwW ❑a