Loading...
HomeMy WebLinkAbout2669 Flicker Cv 18-3489 (A) NEW SFH� ao �� Building &Fire Prevention Division PERMIT APPLICATION FIRE DEPARTMENT Application No: IF— 3 l B 9 3312o1 Documented Construction Value: $ Job Address: abbg T 1;cox CbyL-. Skn�e(,� FI 12773Historic District: Yes No Parcel ID: 17-20-31-502-0000-1 A9 0 Residential Commercial Type of Work: Neww] Addition[] Alteration Repair Demo❑ Change of Use❑ Move❑ Description of Work: NEW SINGLE FAMILY HOME WYNDHAM PRESERVE LOT # k 19 Plan Review Contact Person: ANTHONY PERROTTI Phone: 407-592-4187 Title: Account Manager Fax: Email: Anthony@PermitsPermitsPermits.com NTA Property Owner Information Anthony Perrotti 407-592-4187 Name Park Square Enterprises LLC Street: 5200 Vineland Rd STE 100 City, State Zip: Orlando FL 32811 Phone: Anthony@PermitsPerm its Permits. com Resident of property? : Contractor Information Name VISHAAL S GUPTA - PARK SQUARE HOMES Phone: 407-5293100 Street: 5200 Vineland Rd STE 100 City, State Zip: Name: Street: City, St, Zip: _ Orlando FL 32811 Bonding Company: Address: N/A Fax: State License No.: CRC1330351 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: N/A Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6" Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: N C� Documented Construction Value: $ 2,400.00 .lob Address: 2669 Flicker Cove, Sanford 32771 (Lot 119) Historic District: Yes ❑ No ❑ Parcel ID: Parent 17203150100000010 Residential ❑X Commercial ❑ Type of Work: New ❑ Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of work: Temporary Construction Trailer - no bathroom Plan Review Contact Person: Michelle Parkison Phoue:407-529-3135 Fax: Name Park Square Enterprises LLC Street: 5200 Vineland Rd Suite 200 City, State Zip: Orlando, FL 32811 Title: Permitting Manager Email: mparkisonnparksquarehomes.com Property Owner Information Phone: 407-529-3000 Resident of property? No Contractor Information Name Park Square Homes/ Vishaal Gupta Pltone: 407-529-3000 Street: 5200 Vineland Rd Suite 200 Fax: 407-529-3001 City, State Zip: Orlando, FL 32811 Name: Street: City, St, Zip: Bonding Compaily: State License No.: CRC1330351 Architect/Engineer Information Phone: Fax: E-mail: — Mortgage Lender: Address: Address: WARNING TO O'VYNER: YOUR FAILURE TO RECORD A NOTICE; OF CONINIENCEMENT i11AY RESULTIN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF CONINIENCEAIENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE TRE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NO'T'ICE OF COMMENCEMENT. Application is hereby (rtade to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. 1+BC 105.3 Shall be inscribed with the date of application and (lie code in effect as of that date: 5"' Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application PIER & STRAPPING SCHEDULE 30' BOX 6 PIERS 0 U PER SIDE O Ill- 30' BOX 130 MPH 3 STRAPS PER SIDE 30' BOX 140 MPH 4 STRAPS PER SIDE xw 30' BOX 150 MPH 4 STRAPS PER SIDE O J z 30' BOX 160 MPH 5 STRAPS PER SIDE Q 30' BOX 170 MPH 6 STRAPS PER SIDE z BOX 180 MPH 7 STRAPS PER SIDE �HVHZ�30' HVHZ 40' BOX 7 PIERS PER SIDE 40' BOX 130 MPH 5 STRAPS PER SIDE 40' BOX 140 MPH 5 STRAPS PER SIDE 40' BOX 150 MPH 6 STRAPS PER SIDE 40' BOX 160 MPI-] 6 STRAPS PER SIDE 40' BOX 170 MPH 7 STRAPS PER SIDE 40' BOX 180 MPH 8 STRAPS PER SIDE �HVHZ� HVHZ 44' BOX 8 PIERS PER SIDE 44' BOX 130 MPH 5 STRAPS PER SIDE 44' BOX 140 MPH 5 STRAPS PER SIDE 44' BOX 150 MPH 6 STRAPS PER SIDE 44' BOX 160 MPH 7 STRAPS PER SIDE 44' BOX 170 MPH 8 STRAPS PER SIDE BOX 180 MPH 9 STRAPS PER SIDE �HVHZ�44' HVHZ 46' BOX 8 PIERS PER SIDE 46' BOX 130 MPH 5 STRAPS PER SIDE 46' BOX 140 MPH 5 STRAPS PER SIDE 46' BOX 150 MPH 6 STRAPS PER SIDE 46' BOX 160 MPH 7 STRAPS PER SIDE 46' BOX 170 MPH 8 STRAPS PER SIDE BOX 180 MPH 9 STRAPS PER SIDE �HW$46' HVH 52' BOX 9 PIERS PER SIDE 52' BOX 130 MPH 5 STRAPS PER SIDE 52' BOX 140 MPH 5 STRAPS PER SIDE 52' BOX 150 MPH 6 STRAPS PER SIDE 52' BOX 160 MPI-] 7 STRAPS PER SIDE 52' BOX 170 MPH 8 STRAPS PER SIDEMHZ HZ) 52' BOX 180 MPH 9 STRAPS PER SIDE ) 56' BOX 10 PIERS PER SIDE 56' BOX 130 MPH 5 STRAPS PER SIDE 56' BOX 140 MPI-] 6 STRAPS PER SIDE 56' BOX 150 MPH 7 STRAPS PER SIDE 56' BOX 160 MPH 8 STRAPS PER SIDE 56' BOX 170 MPH 9 STRAPS PER SIDE (HVHZ 56' BOX 180 MPI-] 10 STRAPS PER SIDE (HVHZ) 60' BOX 10 PIERS PER SIDE 60' BOX 130 MPH 6 STRAPS PER SIDE 60' BOX "140 MPH 7 STRAPS PER SIDE 60' BOX 150 MPH 8 STRAPS PER SIDE 60' BOX 160 MPI-] 9 STRAPS PER SIDE 60' BOX 170 MPH 10 STRAPS PER SIDEFIVFIZ 60' BOX 180 MPH 11 STRAPS PER SIDE ((HVHZ n r n,..8 JI -]IMS w i I,.. --OPTIONAL CAP BLOCK 16"x18"0/8" ABS PAD- --8"x8"x•16" BLOCK NOTE: MAXIMUM OF (2) LAYERS OF WOOD MAY BE USED. A PIER "A" 14 I.7C LE- S/4"l = tI-Olt z 0 U F- v) J L m OU rr 0 SFE MODULAR BUILD] IaL _!Ln�_ 111111 -TUT L w F.T. F.T. LLLU UTE: THIS FOUNDATION PLAN WAS DESIGNED IN ACCORDANCE WITH THE FBC 5th EDITION & THE 2015 EPCOT BUILDING CODE. NOTE: STEEL PIERS MAY BE SUBSTITUTED IN LIEU OF THE MASONRY PIERS SHOWN. NOTE: LESSEE/END USER IS RESPONSIBLE FOR LOCATING SIZE ALL UNDERGROUND UTILITIES AND OBSTRUCTIONS. FOUNDATION PLAN OTE: LESSEE/END USER IS RESPONSIBLE FOR CONDUCTING SCALE: 1/41' = I' -01I A "PULL TEST' IF REQUIRED FOR PERMITTING. 16"x18"x3/4" ABS PAD (MINUTE MAN PRODUCT OR AN APPROVED EQUAL) J D 1- ¢ 1= ¢ ILI � 0 U Z O Ill- D U o� ly- N W GENERAL NOTE: C-) � O O ® ® � 0 / T Z U O V Z ¢ O ¢Q xw J J W >¢ ro C) V) V) ANCHORS ABILITY O J z UPLIFT MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. o Q V) z 0 L� TYP. ANCHOR TYPES SCALE: -NTS- - SYMBOLS TF.T. FRAME TIE -DOWN FASTENED TO GROUND ANCHOR P.T. 2x8 SHIMS 2S 11% : 2 - 4"x8"x16" CAP BLOCK �i °O 1 (3) 16"X18" ABS PAD 4 2 - 8"x8"x16" BLOCK _ .......:......... . NOTE: MAXIMUM OF (2) LAYERS 1 -g 2'-8" OF WOOD MAY BE USED. NOTE: EACH ADDITIONAL COURSE OF BLOCK 3) 16"x•18%3/4" ABS PADS STACKED MUST BE SET PERPINDICULAR TO THE PREVIOUS MINUTE MAN PRODUCT OR AN APPROVED COURSE. EQUAL) PIERS 3211- 40" SCALE: 3/4" = P-0" PER 1"7 B SECTION TIE DOWN, SIDEWALL(TYP.) __ A n SCALE: 3/411= P -O" ABER BEYOND A (TYP) X66 FOUNDATION NOTES. MATERIAL SPECIFICATIONS: SOIL & SITE PREPARATION: 1. FOUNDATION DESIGN IS BASED ON AN ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF.•IAN Y SOIL CONDITIONS THAT MAY DIFFER FROM THIS MUST BE BROUGHT TO THE fTTENTION OF THE ARCHITECT, 2. FOUNDATIONS SHALL BE BUILT ON UNDISTURBED SOIL OR PROPERLY COMPACT FILL MATERIAL. COMPACTED SOILS SHALL BE TESTED TO A MINIMUM OF 95% PROCTOR IN ACCORDANCE WITH ASTM D 1557. 3. EXCAVATIONS FOR FOUNDATIONS SHALL BE BACKFILLED WITH SOIL WHICH IS FREE OF ORGANIC MATERIAL, CONSTRUCTION DEBRIS, AND LARGE ROCKS. 4. LESSEE/END USER IS RESPONSIBLE FOR INSURING THAT SITE/SOIL CONDITIONS MEET OR EXCEED THE REQUIREMENTS SHOWN. BASE PAD: I. PIER FOOTING TYPE "A" SHALL BE 16"X18" ABS PAD OR 16"X16"X4", 2500 PSI CONCRETE PAD. PIER TYPE "B" SHALL USE (3) 16"X18" PADS STACKED, 2, CONCRETE IN FOOTINGS SHALL HAVE A SPECIFIED COMPRESSIVE S'T'RENGTH OF NO LESS 'THAN 2500 PSI AI' 28 DAYS. MASONRY UNIT: 1. PIERS SHALL BE CONSTRUCTED WITH NOMINAL 8"X8"X16" CONCRETE MASONRY UNITS CONFORMING TO ASTM C-90. WOOD & SHIM MATERIAL: 1. ALL WOOD BLOCKING AND SHIMS SHALL BE CEDAR OR PRESSURE TREATED. GROUND ANCHORS: L„ 1. GROUND ANCHORS SHALL HAVE 47254 MIN. ULTIMATE CAPACITY & SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. TIE -DOWN STRAPS: 1. THE TIE -DOWN S'T'RAPS SHALL BE 1-q'" X 0.35" GALVANIZED STEEL QQS-781-H TYPE 1 FINISH -B, GRADE -1. TLE -DOWN STRAPS ANC CONNECTING HARDWARE SHALL HAVE 4725# MIN. ULTIMATE CAPACITY. INSTALLATION SPECIFICATIONS: SOIL & SITE PREPA P.ATION: 1. WHERE WATER IMPACTS THE GROUND FROM A ROOF VALLEY, DOWN SPOUT, SCUPPER, OR O'T'HER RAINWATER COLLECTION OR DIVERSION DEVICE, PROVISIONS SHALL BE MADE TO PREVENT SOIL EROSION AND DIRECT THE WATER AWAY FROM THE FOUNDATION. 2. FINISH GRADE SHALL BE SLOPED AWAY FROM THE FOUNDATION FOR DIWNAGE. THE ARES`• UNDER FOOTINGS, FOUNDATIONS, AND CONCRETE SLABS ON GRADE SHALL H:^, VE NO VEGII'ATION, S'L'UMPS, ROOTS, AND FOREIGN MATERIAL REMOVED PRIOR TO THEIR CONSTRUCTION. FILL MATERIAL SHALL BE FREE OF VEGETATION AND FOREIGN MATERIAL. RECORD COPY MASONRY UNIT: 1. LONG DIMENSION OF ALL PIERS MAY BE INSTALLED PER PINDICULAR OR PARALLEL TO THE FRAME. MAXIMUM OF (4) COURSES, (32" HIGH) UNLESS O'T'HERWISE NOTED. 2. FOUNDATION WALLS OF HOLLOW MASONRY CONSTRUCTION SHALL BE CAPPED WITH 4" OF SOLID MASONRY OR CONCRETE, OR SOLID 2x P.T. LUMBER. 3. CONCRETE MASONRY UNIT'S SHALL CONFORM TO THE ASTM C 90 STANDARDS. 4. CONSTRUCTION.OF DRY -STACKED, SURFACE BONDED MANSONRY WALLS WHEN S ECTFIED I C G A 00, CD �! r p r( r I` 00 o0 oo 0c z 00 0_. c �✓ n- u cn W yr Z (D Q c a N w f= CL W Q Q Q QO LL D O o LL Z a < O b � r —1 r� n Ct P , N LUDIN ST CKING AND LEVELING OF ALL UNITS, MIXING AND THF, • APPLICATION OF MOR'T'AR, CURING AND PROTECTION SHALL COMPLY WITH ASTM C 946. TIE -DOWN STRAPS; LL 1. THE FIRS 1' TIE -DOWN STRIP FROM THE ENDWALL SHALL NOT EXCEED 2'-611. uj 2. REFER TO TIE -DOWN CHART FOR MINIMUM NUMBER OF GROUND ANCHORS, NUMBER OF ANCHORS MAY VARY FROM WHAT IS SHOWN ON THE FOUNDATION �/� PLAN. V r O 5th Edition FBC w/ 2016 SUPPLEMENTS DESIGN LOADS: 1. BASIC WIND SPEED- SEE PIER & STRAPPING SCHED. 2, RISK CATEGORY : II 3. WIND EXPOSURE: C 4. INTERNAL PRESSURE COEFF.: ' ; 0.18 SANFC RD BUII_DINQ DIVISION A PERMIT IS UED SHALL BE CONSTRUED TO BE A LICENSE TO P IOCEED WITH THE WORK AND NOT A H Y ''O VIOLATE, CANCEL, ALTER OR SET CONSULTING ARCHIVE ANY THE PROVISIONS OF THE TECHNICA (. 3, NO ' 1ALL ISSUANCE OF A PERMIT PREVE THOMAS L. MELTON THE Bl L ING OFFICIAL FROM THEREAFTER REQUIRIN i CORRECTION OF ERRORS IN PLANS FLORIDA # AR0017033CQN5rF C rION OR VIOLATIONS OF THIS CODE REVISION DATE: DATE: 04-17-2017 0SA/Vp0no DRAWN: R.C.S. JOB #: STOCH SHEET NO. A4 I'D COPYNIGH f 2007 MUUI II_AR PI AN`,.; DESIGN, CO ---- , , , , D U 1= J � U) Z ANCHOR Ill- D o� EIle N GENERAL NOTE: SANFC RD BUII_DINQ DIVISION A PERMIT IS UED SHALL BE CONSTRUED TO BE A LICENSE TO P IOCEED WITH THE WORK AND NOT A H Y ''O VIOLATE, CANCEL, ALTER OR SET CONSULTING ARCHIVE ANY THE PROVISIONS OF THE TECHNICA (. 3, NO ' 1ALL ISSUANCE OF A PERMIT PREVE THOMAS L. MELTON THE Bl L ING OFFICIAL FROM THEREAFTER REQUIRIN i CORRECTION OF ERRORS IN PLANS FLORIDA # AR0017033CQN5rF C rION OR VIOLATIONS OF THIS CODE REVISION DATE: DATE: 04-17-2017 0SA/Vp0no DRAWN: R.C.S. JOB #: STOCH SHEET NO. A4 I'D COPYNIGH f 2007 MUUI II_AR PI AN`,.; DESIGN, CO ---- , , , , REVIEWED FOR CODE COMPLIANCE J GROUND ANCHOR _ NOTEe,F ee� PLANS EXAMINER GENERAL NOTE: lE5-I4-%'I DATE ® ® � STABILIZER PLATES ARE NOT REQUIRED WITH INSTALLATION. HOWEVER ANY UNSTABLE SOIL CONDITIONS THAT MAY IMPACT THE GROUND ANCHORS ABILITY TO RESIST UPLIFT MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. SANFC RD BUII_DINQ DIVISION A PERMIT IS UED SHALL BE CONSTRUED TO BE A LICENSE TO P IOCEED WITH THE WORK AND NOT A H Y ''O VIOLATE, CANCEL, ALTER OR SET CONSULTING ARCHIVE ANY THE PROVISIONS OF THE TECHNICA (. 3, NO ' 1ALL ISSUANCE OF A PERMIT PREVE THOMAS L. MELTON THE Bl L ING OFFICIAL FROM THEREAFTER REQUIRIN i CORRECTION OF ERRORS IN PLANS FLORIDA # AR0017033CQN5rF C rION OR VIOLATIONS OF THIS CODE REVISION DATE: DATE: 04-17-2017 0SA/Vp0no DRAWN: R.C.S. JOB #: STOCH SHEET NO. A4 I'D COPYNIGH f 2007 MUUI II_AR PI AN`,.; DESIGN, CO ---- , , , , F.I.F ELEV 2'-6"(2.50') c END OF RAMP VIEW i" DIRECTION/ 7'-4" LANDING w RSl SCALE: 3/4" = I'-0" V ' ❑ 2"x5"x1/8" C' 5'-4" i\ DENOTES ANCHOR LOCATION SEE PAGE 9 FOR DETAILS AND NOTE #17 ON COVER PAGE L- II li li I 4'-0" x 10'-0" 4'-0" x 10'-0" RAMP SECTION RAMP SECTION it II r 4'-0" x 10'-0" RAMP SECTION ELEV-1 0'-0"(0.00') RAMP DOWN (1:12 MAX.) H RS1 TIE DOWN PLAN SCALE: 3/16" = 1'-0" TIE -DOWN DESIGN LOADS: WIND LOAD: 180 MPH rvnr.ni irir i--.nrr��r-w. n ELEVATION PLAN SCALE: 3/16" = V-0" W V r NOTE: NO OPENING WILL ALLOW A 4" SPHERE TO PASS THROUGH. ri�rd- NOTE: ALL OTHER LANDING WALKING RAILS SIMILIAR SURFACE I 5'-4" ELEVATION VIEW A 5'-411 LANDING RAIL RS1 SCALE: 1 1/2" = F-0" UM0 1-MAINNEL #14 x 3/4" LONG SELF 2" x 5" x 3/16" DRILLING PAN HEAD SCREW (12" O.C. MAX) 1/8" 2-12 1/81, 2-12 2"x5"x1/8" URS DECK ANGLE 3/4"x0. 6" OR 8" SELF MATING EXTRUDE[ QK ALUMINUM DECK WITH SLIP RESISTANT SURFACE 1 1 /2"x1 "x0.093" 2"x5"x1/8" SNAP CHANNEL f� SELF MATING CHANNEL W/ CLOSURE iC 1/8" V CORNERLANDISNG PLAN VIEW 1"x3"x1/8" RECT. ALUM. TUBE STRINGER, a 51-4 11 S Q LANDING R$1 SCALE: 1 1/2" = V-0" 11" STAIR TO LANDING CONNECTION 2 2RS1 1/8 1 DETAIL 2"x5"x SELF -MATING CHAN 1 7/16"x WALL TUBE VEF DENOTES ANCHOR LOCATION M c END OF RAMP VIEW A w RSl SCALE: 3/4" = I'-0" V GENERAL NOTES: ❑ 2"x5"x1/8" C' 1. V �1 b � 2 DETAIL SELF MATING ALUM. ALUMINUM ASSOCIATION SPECIFICATIONS AND GUIDELINES FOR ALUMINUM STRUCTURES: uj F_ � CHANNEL W/,125" TO BE 6061-T6, 6063-T6 AND 6005-T5ALUMINUM ALLOY, RS1 N RADIUS EDGES i� 5, WELDING SHALL BE IN ACCORDANCE WITH ANSI/AWS D1:2-97 GAS METAL ARC WELD :NG CGMAW) SCALE: NTS 6, m i 7. LANDING, RAMP, AND STAIR SECTIONS ARE TO BE ENGINEERED FOR A 10OPSF LIVE _❑AD. 8. LANDING AND RAMP WALKING SURFACES SHALL BE DESIGNED FOR A MINIMUM C❑NCEHTRATED EXTRUDED SLIP -RESISTANT VERTICAL LOAD OF 300 LBS APPLIED EVENLY OVER A 12"x12' AREA: STAIR TREPDS SHALL j 2"x5"x1/8" URS DECK ANGLE 3/4"x0. 6" OR 8" SELF MATING EXTRUDE[ QK ALUMINUM DECK WITH SLIP RESISTANT SURFACE 1 1 /2"x1 "x0.093" 2"x5"x1/8" SNAP CHANNEL f� SELF MATING CHANNEL W/ CLOSURE iC 1/8" V CORNERLANDISNG PLAN VIEW 1"x3"x1/8" RECT. ALUM. TUBE STRINGER, a 51-4 11 S Q LANDING R$1 SCALE: 1 1/2" = V-0" 11" STAIR TO LANDING CONNECTION 2 2RS1 1/8 1 DETAIL 2"x5"x SELF -MATING CHAN 1 7/16"x WALL TUBE VEF DENOTES ANCHOR LOCATION M c ISO RAMP W/ RAILING RS1 SCALE: 3" = U-0" STAIR STRINGERRS1 SLIP -RESISTANT STAIR TREAD 3 2" x 8" x 1/8" ALUM TUBE SCALE: 3"=1'-0" 24 I L--� 0 (TYPICAL) L— o LANDING URS CHANNEL w 2" x 5" x 1/8" W EACH OCCURANCE 1"-3" U) U) - 1/4" x 3/4" LG SELF. U- DRILLING HEX HEAD SCREW co EACH OCCURANCE 1/8" 1"-12" EACH VERTICAL LEG (EVERY TREAD) 1/8" 1 1/4" EACH OCCURANCE 1/8" 2-12 RISER PLATE 8" x 1/8" THK c END OF RAMP VIEW A w RSl SCALE: 3/4" = I'-0" V GENERAL NOTES: ❑ 2"x5"x1/8" C' 1. V ♦��^^ � 2 DETAIL SELF MATING ALUM. ALUMINUM ASSOCIATION SPECIFICATIONS AND GUIDELINES FOR ALUMINUM STRUCTURES: uj F_ � CHANNEL W/,125" TO BE 6061-T6, 6063-T6 AND 6005-T5ALUMINUM ALLOY, RS1 N RADIUS EDGES i� 5, WELDING SHALL BE IN ACCORDANCE WITH ANSI/AWS D1:2-97 GAS METAL ARC WELD :NG CGMAW) SCALE: NTS 6, m 7. c ISO RAMP W/ RAILING RS1 SCALE: 3" = U-0" STAIR STRINGERRS1 SLIP -RESISTANT STAIR TREAD 3 2" x 8" x 1/8" ALUM TUBE SCALE: 3"=1'-0" 24 I L--� 0 (TYPICAL) L— o LANDING URS CHANNEL w 2" x 5" x 1/8" W EACH OCCURANCE 1"-3" U) U) - 1/4" x 3/4" LG SELF. U- DRILLING HEX HEAD SCREW co EACH OCCURANCE 1/8" 1"-12" EACH VERTICAL LEG (EVERY TREAD) 1/8" 1 1/4" EACH OCCURANCE 1/8" 2-12 RISER PLATE 8" x 1/8" THK TOP OF RAMP DECK co c, 1 RS1 ---_.... RAIL MOUNTING POCKET 2" x 2" x 1/8" TUBE CIDI 1/4"x3/4" H.H. SELF oDRILLING SCREWS (TYP) 1'-0" U.C. MIN. 1/8" 1/2" @ EVERY RIB F RAMP TO RAIL CONNECTION ELE V A•I •IUN PLAN SCALE: 3/16" = 1'4 ALL RECTANGULAR LANDINGS o TOP OF LANDING THRESHOLD 'z V1 1/4" D EA. LEG 1/8" 1/2" @ EA. RIB1/8"O 0 .a LL PRESSURE TREATED WOOD BLOCKS (EVERY 18' TO 24" O.C.j/ DIFFERENT TYPES OF ATTACHMENT: 1.) FOR ATTACHMENT LIGHT GAUGE METAL JOIST: THROUGH BOLT WITH 5/16" DIA. HEX -HEAD BOLT, FLAT WASHER, & 5/16" NUT. (12" O.C. MAX.) 2.) FOR ATTACHMENT TO WOOD: 5/16" DIA. HEX - HEAD LAG SCREWS (12" O.G. MAX.) 3.) FOR ATTACHMENT CEMENT: 3/8" DIA. HEX - HEAD SLEEVE ANCHORS. (12" O.C. MAX.) RAMP TO RAIL CONNECTION SCALE: 1 1/2" = P-0" 11 15/16" SCALE: 1 1/2" = P-0" 3 3/4" (INSIDE/INSIDE) i SEE NOTE BEL 3"x3"x1/4" THK ANGLE x6 3/4" V-6" MIN LEVEL 12 \ I. (TYP) I� 1 "LOWER END HOOP cv r 12 I 1 / FINISHED GRADE WALKING SURFACE VERTICAL PICKET GUARDRAIL 1/4" THK TRANSITION PLATE 1 1/2"x 6" AND 8" ALUM. DECK W/SLIP RESISTANT SURFACE NOTE: NO OPENING WILL ALLOW A 4" SPHERE TO PASS THROUGH. c END OF RAMP VIEW A CROSS SECTION RSl SCALE: 3/4" = I'-0" V GENERAL NOTES: 2"x5"x1/8" C' 1. ALUMINUM RAMP, LANDING AND STAIR SECTIONS SHALL BE A RIGID, FREE -SPAN DESIGN, ♦��^^ 2, 2 DETAIL SELF MATING ALUM. ALUMINUM ASSOCIATION SPECIFICATIONS AND GUIDELINES FOR ALUMINUM STRUCTURES: uj 3. ALUMINUM CONSTRUCTION USING THE 6000 SERIES ALUMINUM ALLOYS, STRUCTURAL MEMBERS CHANNEL W/,125" TO BE 6061-T6, 6063-T6 AND 6005-T5ALUMINUM ALLOY, RS1 2 3/4"X1 1/2" STAIR URS HINGE RADIUS EDGES i� 5, WELDING SHALL BE IN ACCORDANCE WITH ANSI/AWS D1:2-97 GAS METAL ARC WELD :NG CGMAW) SCALE: NTS 6, ALL FASTENERS TO BE III -8 (SERIES 304) STAINLESS STEEL UNLESS OTHERWISE NITED. 7. LANDING, RAMP, AND STAIR SECTIONS ARE TO BE ENGINEERED FOR A 10OPSF LIVE _❑AD. 8. LANDING AND RAMP WALKING SURFACES SHALL BE DESIGNED FOR A MINIMUM C❑NCEHTRATED EXTRUDED SLIP -RESISTANT VERTICAL LOAD OF 300 LBS APPLIED EVENLY OVER A 12"x12' AREA: STAIR TREPDS SHALL j BE DESIGNED TO WITHSTAND A MINIMUM CONCENTRATED LOAD OF 300 LBS OVER A 4 INCH ALUMINUM STAIR TREAD (TYPICAL) AREA, J TOP OF RAMP DECK co c, 1 RS1 ---_.... RAIL MOUNTING POCKET 2" x 2" x 1/8" TUBE CIDI 1/4"x3/4" H.H. SELF oDRILLING SCREWS (TYP) 1'-0" U.C. MIN. 1/8" 1/2" @ EVERY RIB F RAMP TO RAIL CONNECTION ELE V A•I •IUN PLAN SCALE: 3/16" = 1'4 ALL RECTANGULAR LANDINGS o TOP OF LANDING THRESHOLD 'z V1 1/4" D EA. LEG 1/8" 1/2" @ EA. RIB1/8"O 0 .a LL PRESSURE TREATED WOOD BLOCKS (EVERY 18' TO 24" O.C.j/ DIFFERENT TYPES OF ATTACHMENT: 1.) FOR ATTACHMENT LIGHT GAUGE METAL JOIST: THROUGH BOLT WITH 5/16" DIA. HEX -HEAD BOLT, FLAT WASHER, & 5/16" NUT. (12" O.C. MAX.) 2.) FOR ATTACHMENT TO WOOD: 5/16" DIA. HEX - HEAD LAG SCREWS (12" O.G. MAX.) 3.) FOR ATTACHMENT CEMENT: 3/8" DIA. HEX - HEAD SLEEVE ANCHORS. (12" O.C. MAX.) RAMP TO RAIL CONNECTION SCALE: 1 1/2" = P-0" 11 15/16" SCALE: 1 1/2" = P-0" 3 3/4" (INSIDE/INSIDE) i SEE NOTE BEL 3"x3"x1/4" THK ANGLE x6 3/4" V-6" MIN LEVEL 12 \ I. (TYP) I� 1 "LOWER END HOOP cv r 12 I 1 / FINISHED GRADE WALKING SURFACE VERTICAL PICKET GUARDRAIL 1/4" THK TRANSITION PLATE 1 1/2"x 6" AND 8" ALUM. DECK W/SLIP RESISTANT SURFACE NOTE: NO OPENING WILL ALLOW A 4" SPHERE TO PASS THROUGH. SCALE: 3" = 1'-0" V-6" LONG xm5/8" 1 1/4"x0.035" TIE -DOWN EARTH STRAPPING ANSI & ANCHOR WITH GROUND ASTM CERTIFIED DOUBLE HELIX AND STABILIZER PLATE BEHIND ANCHOR 5"x1 /8" IBE z 0 E TIE DOWN EARTH ANCHOR RS1 SCALE: 1 1/2" = 1'-0" FBC, 5TH EDITION W/ 2016 SUPP COMPLIANCE STATEMENT: 1. BASIC WIND SPEED- 180 MPH (HVHZ) 2. RISK CATEGORY: II 3. WIND EXPOSURE: C 4. DECK LIVE LOAD: 100 PSF 5. HANDRAIL IMPACT: 200 PSF DESIGN CRITERIA COMPLIANCE STATEMENT: FLORIDA BUILDING CODE, 5TH ED W/ 2016 SUPP FFPC, 5TH EDITION W/ 2016 SUPPLEMENTS 2015 EPCOT BUILDING CODE W 2016 & 2017 SUPP 2015 EPCOT ACCESSIBILITY CODE W/ 2016 SUPP REVISION DATE: Q CUPYRIGhiT 2015 -MODULAR PLAN5 DESIGN, CO. CONSULTIN(I ARCHITECT THOMAS L. MELTON FLORIDA # AROO17033 ❑ M 0 o 0 w co G a -o 00 OD0� co CID� .co co } Co coo GGo m a U- z a. ❑ O 0 N w a U) w Q ¢w < O 00 u Q v�-jM w n QY co 4 J M C.7 0 UD z =ET NO. RS -1 c END OF RAMP VIEW A RSl SCALE: 3/4" = I'-0" V GENERAL NOTES: C' 1. ALUMINUM RAMP, LANDING AND STAIR SECTIONS SHALL BE A RIGID, FREE -SPAN DESIGN, ♦��^^ 2, DESIGN OF THE ALUMINUM STRUCTURES SHALL CONFORM TO THE CURRENT EDITION CIF THE y V) SCALE: 3" = 1'-0" V-6" LONG xm5/8" 1 1/4"x0.035" TIE -DOWN EARTH STRAPPING ANSI & ANCHOR WITH GROUND ASTM CERTIFIED DOUBLE HELIX AND STABILIZER PLATE BEHIND ANCHOR 5"x1 /8" IBE z 0 E TIE DOWN EARTH ANCHOR RS1 SCALE: 1 1/2" = 1'-0" FBC, 5TH EDITION W/ 2016 SUPP COMPLIANCE STATEMENT: 1. BASIC WIND SPEED- 180 MPH (HVHZ) 2. RISK CATEGORY: II 3. WIND EXPOSURE: C 4. DECK LIVE LOAD: 100 PSF 5. HANDRAIL IMPACT: 200 PSF DESIGN CRITERIA COMPLIANCE STATEMENT: FLORIDA BUILDING CODE, 5TH ED W/ 2016 SUPP FFPC, 5TH EDITION W/ 2016 SUPPLEMENTS 2015 EPCOT BUILDING CODE W 2016 & 2017 SUPP 2015 EPCOT ACCESSIBILITY CODE W/ 2016 SUPP REVISION DATE: Q CUPYRIGhiT 2015 -MODULAR PLAN5 DESIGN, CO. CONSULTIN(I ARCHITECT THOMAS L. MELTON FLORIDA # AROO17033 ❑ M 0 o 0 w co G a -o 00 OD0� co CID� .co co } Co coo GGo m a U- z a. ❑ O 0 N w a U) w Q ¢w < O 00 u Q v�-jM w n QY co 4 J M C.7 0 UD z =ET NO. RS -1 c END OF RAMP VIEW A RSl SCALE: 3/4" = I'-0" V GENERAL NOTES: C' 1. ALUMINUM RAMP, LANDING AND STAIR SECTIONS SHALL BE A RIGID, FREE -SPAN DESIGN, ♦��^^ 2, DESIGN OF THE ALUMINUM STRUCTURES SHALL CONFORM TO THE CURRENT EDITION CIF THE v� ALUMINUM ASSOCIATION SPECIFICATIONS AND GUIDELINES FOR ALUMINUM STRUCTURES: uj 3. ALUMINUM CONSTRUCTION USING THE 6000 SERIES ALUMINUM ALLOYS, STRUCTURAL MEMBERS 0. TO BE 6061-T6, 6063-T6 AND 6005-T5ALUMINUM ALLOY, 4, ALUMINUM WILL BE STANDARD MILL FINISH UNLESS OTHERWISE NOTED: ♦�y 5, WELDING SHALL BE IN ACCORDANCE WITH ANSI/AWS D1:2-97 GAS METAL ARC WELD :NG CGMAW) vn 6, ALL FASTENERS TO BE III -8 (SERIES 304) STAINLESS STEEL UNLESS OTHERWISE NITED. 7. LANDING, RAMP, AND STAIR SECTIONS ARE TO BE ENGINEERED FOR A 10OPSF LIVE _❑AD. 8. LANDING AND RAMP WALKING SURFACES SHALL BE DESIGNED FOR A MINIMUM C❑NCEHTRATED VERTICAL LOAD OF 300 LBS APPLIED EVENLY OVER A 12"x12' AREA: STAIR TREPDS SHALL j BE DESIGNED TO WITHSTAND A MINIMUM CONCENTRATED LOAD OF 300 LBS OVER A 4 INCH AREA, 9, RAMP AND LANDING GUARDRAILS TO BE 42 INCH MINUMUM HEIGHT UNLESS OTHERWISE �✓ SPECIFIED. (34 AND 38 INCH TWO-LINE RAMP RAILS AND 34 AND 38 INCH VERTIC )L PICKET RAMP RAILS AS WELL AS CUSTOM DESIGN RAMP RAILS AVAILABLE UPON REQUEST -OR SYSTEMS NO MORE THAN 30 INCHES ABOVE FINISHED GROUND LEVEL, 10,HANDRAIL ASSEMBLIES AND GUARDRAILS SHALL BE ABLE TO RESIST A LOAD OF 50 'LF APPLIED IN ANY DIRECTION AT THE TOP ❑F -THE RAIL, 11: HANDRAIL ASSEMBLIES AND GUARDRAILS SHALL BE ABLE TO RESIST A SINGLE CONCENTRATED, LOAD OF 250 LBS, APPLIED IN ANY DIRECTION AT ANY P❑INT ALONG THE TOP OF THE RAIL, THIS LOAD NEED NOT BE ASSUMED TO ACT CONCURRENTLY WITI- THE LOADS SPECIFIED IN THE PRECIDING PARAGRAPH, 12, INTERMEDIATE RAILS ( 1LL -THOSE EXCEPT HANDRAILS), BALUSTERS AND PANEL FILLERS SHALL BE DESIGNED T I WITHSTAND A HORIZONTALLY APPLIED NORMAL LOAD OF 5( LBS ON AN EQUAL TO 1 SQUATS FOOT, INCLUDING OPENINGS AND SPACE BETWEEN RAILS, 13, GUARDRAIL SYSTEMS S TALL BE DESIGNED S❑ -THAT A 4 (FOUR) INCH SPHERE CANN IT PASS THROUGH ANY OPENING, 14, DECK SURFACE SHALL BE SLIP RESISTANT, EXTRUDED ALUMINUM DECKING WITH A RIPLE I -BEAM, SELF -MATING DESIGN, 15, ALL SURFACES, MEMBERS AND THEIR WELDED JOINTS SHALL BE SMOOTH AND FREE FROM SHARP OR JAGGED EDGES, 16.ALL DESIGNS SHOWN HEREIN ARE SUBJECT TO CHANGE PENDING FIELD VERIFICATIO \I OF EXISTING CONDITIONS, (5J) SLOPE RAMP SECTION RAMP @ 1;12 (HANDRAIL NOT INSTALLED) PROPRIETARY HINGE EXTRUSION (SAME WIDTH AS RAMP) TOP OF DECK _ TOP OF – DECK � 1 1/8" 1 1/4" @ EA. LEG 1/8" 1/2" @ EA. RIB RAMP TO LANDING CONNECTOR 1/4"x3/4" SELF DRILLING HEX HEAD SCREWS RAMP TO LANDING CONNECTION SCALE: 3" = 1'-0" V-6" LONG xm5/8" 1 1/4"x0.035" TIE -DOWN EARTH STRAPPING ANSI & ANCHOR WITH GROUND ASTM CERTIFIED DOUBLE HELIX AND STABILIZER PLATE BEHIND ANCHOR 5"x1 /8" IBE z 0 E TIE DOWN EARTH ANCHOR RS1 SCALE: 1 1/2" = 1'-0" FBC, 5TH EDITION W/ 2016 SUPP COMPLIANCE STATEMENT: 1. BASIC WIND SPEED- 180 MPH (HVHZ) 2. RISK CATEGORY: II 3. WIND EXPOSURE: C 4. DECK LIVE LOAD: 100 PSF 5. HANDRAIL IMPACT: 200 PSF DESIGN CRITERIA COMPLIANCE STATEMENT: FLORIDA BUILDING CODE, 5TH ED W/ 2016 SUPP FFPC, 5TH EDITION W/ 2016 SUPPLEMENTS 2015 EPCOT BUILDING CODE W 2016 & 2017 SUPP 2015 EPCOT ACCESSIBILITY CODE W/ 2016 SUPP REVISION DATE: Q CUPYRIGhiT 2015 -MODULAR PLAN5 DESIGN, CO. CONSULTIN(I ARCHITECT THOMAS L. MELTON FLORIDA # AROO17033 ❑ M 0 o 0 w co G a -o 00 OD0� co CID� .co co } Co coo GGo m a U- z a. ❑ O 0 N w a U) w Q ¢w < O 00 u Q v�-jM w n QY co 4 J M C.7 0 UD z =ET NO. RS -1