Loading...
HomeMy WebLinkAbout3000 S Mellonville Ave 18-2786 ELECTRICALG 4 f 4 No: Application1�D. y Documented 1Construction Value-.$ X -7(P Job Address: �� �P %11V11 ' �1 Historic District: Yes ❑ No ❑ Parcel 1l): UP— 'W 3 _ SC0 -•- U212—L0201 Zoning: Description of Work: Plait Review Contact Person: Title: Phone: 40-1 `j (n`_3 ` 3LI C4 5 rax: �o�- 3J -i ( _ E-mail.- Property -mail:Property Owner Information Name �L� 1 � i~ Phone: street: 6 'r <deve j _`ij 1QCf . Resident of property? C �� s City, Mate dip: a G)�Nk;6t Co�ntractor Information wine ., r w / Cu t.Ufi Plione: , G -D -X03 3 q n {� Street:�ye— �aa ii . ii Eax:_ City, State Zip: Mate License iso.: EEd_,DWQRq 0 ko wt -6 -1 0_d. 'P.13 P Maine: Street: City, St, Zip: Bonding Company: Address: Building Permit El Square rootage: No. of Dwelling Units-. Electrical 13 New Service --- No. of AMPS: Aarchitect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: Construction Type: No. of Stories: Flood Zone: Mechanical 0 (Duct layout required for new systems) Plumbing 11 New Construction -Ilio. of Fixtures: Fire Sprinkler/Alarm ® No. of heads: SCOPE OF WORK yIntegrated Security Consolidated-AOE/SOWIFroduct Ordering The scope of work is a description of the project and services to be provided. It is a short narrative to include design brief, deliverables both products and services, and project objectives; Le., "what are we trying to accomplish for the customer?" SCOPE OF WORK Contact Information: Michael Magner (321)696-2827. Michael.magner@toro.com System Operation: Replace existing end -of -life Focus 200 panel which controls and monitors fire alarm and security for building. Furnish install, program, commission and test: 1-TYC250FBP alarm control panel w/battery backup and power supply; phone room 1 -Dual line supervised dialer module 1 -Smoke detector above control panel 1- TYCO6160CR annunciator/keypad main entry 1-IYG06160 keypad employee entrance 1 -Key Box exterior main entry 23- zone interface modules 5- Door contacts connect existing 4- Overhead door contacts connect existing a -Motion sensors connect existing 1-waterilow switch connect existing _ 1- valve tamper switch connect existing - note waterflow and valve tamper switches to zones 'onboard" control panel. Do not connect to vplex loop. -install surge suppression devices for panel power, waterflow and valve tamper switch circuit and alarm system telephone line circuits. -The installer will follow the steps below to test an alarm system and any backup communication system. Step Action 1 -Arm the system and test each device 2 -Backup communication systems, If installed. Remove primary means of communication and test the backup system. 3 -Gail the VRT to verify all signals and restores. 4 -ITS will issue a confirmation number and place the system in service after all devices (zones) and backup communication has been verified. - All zones to be labeled indicating device location description and number. Use up to 32 Characters as needed to describe device and location. Customer responsible to label devices if so desired. Programming Info: -Standard Intrusion System programming -standard Fire System programming Program open/close logging Site Conditions: - Existing construction; 6-12' ladders & Lift required. Lift on video proposal. Report Generated for. MBURNS on: 0222812018 Estimate#: 130T106Y Rev#: 1 Page 10 of 16 tyCo Integratedsecurity Consolidated - AOEISOW/Product Ordering Existing Equipment: Focus 200 w/ PIDS Customer Expectations: Disruptions to be kpi)t to a minimum and ensure areas of work are clean before leaving. Johnson Controls Tmohniclans are to sign in and out of customer's premise, if required by the customer. if required by the customer Johnson Controls Technicians =hall personally check in the contact person upon arrival and upon departure. - System installation atiali be in a good and workmanlike manner. Training Expectations: - Johnson Controls Socurity installers are to train the designated person or persons on the full operation of all systems. This is to include adding, deleting user codes, viewing alarm history on the keypads, reviewing zones and resetting of the system. -Train customer on use of system including silencing and resetting of alarms and troubles. Ensure that they have been given the master code and personal identification code. Ensurethat the customer has been given their new Johnson Controls Security CS number, phone numbers to contact Johnson Controls Security General Comments: -Fire alarm permit cost included. Customer shall be responsible for the execution of any permit and if required, Notice of Commencement by building representative or property owner. Customer Responsibilities / Tyco Exclusions: -Customer to provide dedicated 120VAC circuit to fire alarm equipment as required for system operation. This shall include a junction box within 3' of system for installation of surge protection equipment. The customer will remove or relocate any customer -owned furniture and/or inventory impeding the installation of wiring and/or devices or the testing of existing devices. - Unrestricted access throughout the facility between the hours of Sam-4:30pm, Monday -Friday (excludes Johnson Controls observed holiday) for system installation. - Customer to provide scaled floor plan in PDF or AutoCad format which accurately depicts current, or If undergoing remodeling, wall, door, window, and any other required for permit plan submittal. Documentation Needs: Completion Packet Drawing Fire Alarm permit User Manual Enhanced Job Details: System Type: BA Product Family: Construction Complexity: Network Integration: Square Footage: Report Generated for. MBURNS on: 02/28/2018 Estimate#: 1-30T106Y Rev*. 1 Page 11 of 16 AREA OF WORK AREA OF WORK IS SHOWING IN RED CONSTRUCTION DOCUMENT SET - NOT ALL INFORMATION OR DEVICES DISPLAYED ON THIS PAGE APPEAR ON DRAWINGS - SYSTEM CODES NFPA 70 NEC ARTICLE 760 2014 FLORIDA BUILDING CODE 6th Edition (2017) FLORIDA FIRE PREVENTION CODE 6th Edition NFPA 101 LIFE SAFETY CODE 2015 WITH FLORIDA AMENDMENTS NFPA 1 UNIFORM FIRE CODE 2015 WITH FLORIDA AMENDMENTS MONITORING LOCATION JOHNSON CONTROLS SECURITY SOLUTIONS, LLC 7805 NW 97TH TER KANSAS CITY MO 64153-2484 1-888-238-2666 ALARM SERVICE CO.: 360682-011 - SERVICE CENTER NUMBER: 265 - UL LISTING: S994-147 GENERAL NOTES: 1. ALL FIRE ALARM DEVICES ARE TO BE INSTALLED ACCORDING THE THE REQUIREMENTS OF NEPA 72 AND THE MANUFACTURES INSTRUCTIONS, 2. ALL FIRE ALARM DEVICES ARE TO BE MOUNTED ON BACK BOXES. 3. ALL FIRE ALARM DEVICES ARE TO BE UL LISTED AND COMPATIBLE, 4. ALL WIRE IS TO BE IN CONDUIT FROM THE DEVICE BACK BOX TO ABOVE THE FALSE CEILING OR TO THE BAR JOISTS. WIRE MAY BE RUN EXPOSED HORIZONTALLY BUT MUST BE ATTACHED TO THE BUILDING STRUCTURE OR SUPPORTED BY APPROVED HANGERS. 5. ALL WIRE IS TO BE POWER LIMITED, TYPE FPLP UNLESS OTHERWISE NOTED. ALL WIRING IS TO BE INSTALLED IN ACCORDANCE WITH THE ADAPTED NFPA 70 (NEC SECTION 760), NFPA 72 AND ALL LOCAL CODES. 6. CONTROL PANELS AND POWER SUPPLIES ARE TO BE MOUNTED AS SH()WING ON DRAWING UNLESS THE AHJ REQUIRES OTHERWISE. THEY ARE TO BE MOUNTED NO MORE THAT 72 INCHES ABOVE THE FLOOR TO THE TOP OF THE CABINET, 7. ANNUNCIATOR/KEYPADS ARE TO BE MOUNTED AT 54 INCHES ABOVE THE FLOOR TO THE TOP OF THE UNIT UNLESS THE AHJ REQUIRES OTHERWISE. 8. MANUAL PULL STATIONS ARE TO BE MOUNTED AT 48 INCHES ABOVE THE FLOOR TO THE CENTER OF THE BOX UNLESS THE AHJ REQUIRES OTHERWISE. 9. WALL MOUNTED HORNS AND STROBES SHALL BE MOUNTED AT 80 INCHES TO THE BOTTOM OF THE BOX ABOVE THE FINISHED FLOOR.THE CANDELA RATING IS NOTED NEAR THE DEVICE ON THE DRAWINGS. 10. CEILING MOUNTED HORNS AND STROBES WILL BE NOTED WITH A "CM".THE CANDELA RATING IS NOTED NEAR THE DEVICE ON THE DRAWINGS, 11. CEILING MOUNTED STROBES ARE SPACED BASED ON A CEILING HEIGHT OF 12' ALL CEILINGS IN THE TENET SPACE ARE 12' OR LESS. 12. THE ELECTRICAL CONTRACTOR IS TO SUPPLY ALL REQUIRED 120VAC TO THE FIRE ALARM CONTROL PANEL AND ALL POWER SUPPLIES ON DEDICATED CIRCUIT(S), THE CIRCUIT(S) ARE TO BE LOCKED AND LABEL "FIRE ALARM DO NOT TURN OFF". LABELING OF CABLE AND PANELS 1. ALL PANELS SHOULD HAVE A LABEL TO DESCRIBE ITS FUNCTION, I.E. 24VDC POWER SUPPLY FOR LOCK POWER AND AUXILIARY DEVICES. 2. ALL CABLE IS TO BE LABELED AT BOTH ENDS AND CABLE DRESSED NEATLY IN PANEL, I,E. FRONT LOBBY DOOR READER, FRONT LOBBY DOOR DSM, FRONT DOOR REQUEST TO EXIT, ETC, 3. JCI TO UTILIZE A LABEL MAKER TO PRINT ALL LABELS (NOT A SHARPIE). IF A HAND WRITTEN LABEL NEEDS TO BE USED IT MUST BE NEAT, LEGIBLE AND PERMANENT. RECORD DRAWINGS: ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ON THESE DRAWINGS AND RETURNED TO THE JCI OFFICE AT THE ADDRESS LISTED ABOVE FOR COMPLETION OF AS -BUILT DRAWINGS. PROPRIETARY AND CONFIDENTIAL INFORMATION NOTICE: THIS PROPOSAL, DRAWING(S) AND RELATED DOCUMENTATION (AND THE INFORMATION HEREIN CONTAINED) IS THE PROPRIETARY, CONFIDENTIAL AND TRADE SECRET INFORMATION OF JOHNSON CONTROLS SECURITY SOLUTIONS, LLC. ("JCI") AND IS SUPPLIED UPON THE EXPRESS CONDITIONS THAT: (1) THE SAME SHALL BE RETURNED TO JCI UPON REQUEST, (2) NO REPRODUCTION OF THIS DOCUMENTATION OR ANY PART THEREOF SHALL BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF JCI. ATTENTION: THESE DRAWINGS MAY CONTAIN CONFIDENTIAL INFORMATION AND SHOULD NOT BE DISTRIBUTED. DRAWING ACCEPTANCE: THIS DRAWING IS TO BE USED ONLY FOR THE PURPOSE OF PLACING AND LOCATING JCI EQUIPMENT AND IS NOT TO BE USED FOR ANY OTHER PURPOSES. IT IS THE RESPONSIBILITY OF THE LOCAL JCI SALES & SERVICE OFFICE (SSO) TO REVIEW THE CONTENT OF THESE DRAWINGS FOR ACCURACY AND COMPLIANCE WITH LOCAL AND STATE CODES PRIOR TO RELEASING THEM TO THE FIELD. SHEET INDEX FA 100 GENERAL SHEET NOTES &LEGENDS FA 101 FLOOR PLAN &SYSTEM LAYOUT FA 102 RISER DIAGRAM &POWER CALCULATIONS HONEYWELL 250FBP-24 FAA ANNUNCIATOR PANEL INSTALLATION CONTRACTOR: JOHNSON CONTROLS SECURITY SOLUTIONS, LLC. FLORIDA LICENSE: EF20000890 PERSONAL PROTECTIVE EQUIPMENT JCI REQUIRES ALL EMPLOYEES USE THE MINIMUM PERSONAL PROTECTIVE EQUIPMENT REQUIRED TO BE WORN BY EMPLOYEES PERFORMING WORK IN THE SECURITY AND FIRE DOMAINS OF THE BUILDING SOLUTIONS NORTH AMERICA BUSINESS. THIS INCLUDES ANY LEADER OR MEMBER OF THE SALES TEAM OR ADMIN/SUPPORT STAFF, IF THEIR WORK PLACES THEM IN THE ENVIRONMENT SPECIFIED BY COMPANY POLICY. POLICY EFFECTIVE DATE: 03.01.2018 - REVISION: 14 SAt4FORD FIRE DEPARTMENT THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR PERMIT. AN ISSUED PERMIT SMALL BE DEEMED PERMISSION TO PROCEED WiTH WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THESE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OFA PERMIT PREVENT THE FIRE PREVENTION DIVISION FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS ON THE PLANS, CONSTRUCTION OR OTHER VIOLATIONS OF THE CODE. REVIEWED BY: MATT MINNETT SANFORD FIRE D PT .��DATE..,,, ' < In si F � s V E4 El 04 FIRE ALARM EQUIPMENT LEGEND ■� = EQUIPMENT USED ON PROJECT SYMBOL DEVICE DESCRIPTION MANUFACTURE PART # FRCP I FIRE ALARM CONTROL PANEL HONEYWELL 250FBP-24 FAA ANNUNCIATOR PANEL HONEYWELL 6160 FSCP FIRE SYSTEM CONTROL PANEL WD WIRELESS DEVICE FAPS FIRE ALARM POWER SUPPLY N4 NEMA 4 - NON CORROSION -PROOF ENCLOSURE FDB FIRE DOCUMENT BOX N12 NEMA 12 - SEALED ENCLOSURE I7ffV_A_C­I VOICE EVACUATION PANEL HS HEIGHT STRIP MIC VOICE EVACUATION REMOTE MICROPHONE MM MULLION MOUNTED cAc CELLULAR ALARM COMMUNICATOR MM MONITOR MODULE - ADDRESSABLE 18/2 CMP CR CONTROL RELAY - ADDRESSABLE E E Op SMOKE DETECTOR - PHOTOELECTRIC HONEYWELL 5193 © MANUAL STATION - PULL STATION F F m HEAT DETECTOR F F F SMOKE DETECTOR - DUCT F CAT 6 RTS REMOTE ALARM INDICATING AND TEST SWITCH Fl -01-1 REMOTE RELAY (FORM -C / DRY CONTACT) FKB_1 KNOX BOX PER AHJ PER AHJ KHS KITCHEN HOOD SYb I EM END OF LINE DEVICE - RESISTOR HONEYWELL 7628 SP SURGE PROTECTION EMERSON FAS -120 TRANSFORMER ENCLOSURE BOSCH D8004 STROBE - WALL - VdM C STROBE - CEILING - CM 9<1 SPEAKER WITH LIGHT - WALL WM 9<1 WP SPEAKER WITH LIGHT - WM - WEATHERPROOF SPEAKER WITH LIGHT - CEILING - CM v FLOW DETECTOR/SWITCH POC VALVE WITH TAMPER DETECTOR/SWITCH POC POST -INDICATOR VALVE 14 ABBREVIATIONS SYMBOL DEVICE DESCRIPTION WM WALL MOUNTED CM CEILING MOUNTED WP WEATHER-PROOF XP EXPLOSION -PROOF EX EXISTING DEVICE ND NEW DEVICE WD WIRELESS DEVICE HD HARD -WIRED DEVICE N4 NEMA 4 - NON CORROSION -PROOF ENCLOSURE N4X NEMA 4X - CORROSION -PROOF ENCLOSURE N12 NEMA 12 - SEALED ENCLOSURE CO CARBON MONOXIDE HS HEIGHT STRIP JM JAMB -MULLION MM MULLION MOUNTED CABLE: A A A A A A A A A THHN s a a a a a B s s 14/2 CMP c C C c C— c c C C 18/4 CMP 18/2 CMP E E E E E =-E E E E CAT 5e F F F F F F F F F CAT 6 COMPOSITE THIS DESIGN INCLUDING SPECIFICATIONS, DRAWINGS AND DESIGN CONCEPTS IS THE PROPERTY OF JOHNSON CONTROLS, (JCI) AND IS FURNISHED ON A CONFIDENTIAL BASIS, WITH THE EXPRESSED UNDERSTANDING THAT IT WILL NOT BE SOLD, TRANSFERRED, COPIED OR USED TO THE DETRIMENT OF JCI WITHOUT WRITTEN PERMISSION. THE RECIPIENT FURTHER AGREES NOTTO DISCLOSE THE CONTENTS TO ANY OTHER PARTY EXCEPT FOR THE SPECIFIC PURPOSE CONTRACTED FOR WITH JCI. JCI MAKES NO REPRESENTATIONS AS TO THE OPERABILITY OR ACCURACY OF ANY SYSTEMS, SUBSYSTEMS, ASSEMBLIES OR OTHER INFORMATION CONTAINED HEREIN UNLESS SPECIFICALLY IDENTIFIED FOR CONSTRUCTION. 24" X 36" - ARCH D SIZE LAST PRINTED: LAST SAVED BY: FILE PATH: E:\ACAD\Master Tyco Drawings\01-Toro Company\State, City\TY-Security Systems\Drawings\2.0 Develoment-DD\180507 - DD01\TORO.dwg Johnson Controls JOHNSON CONTROLS 6830 SHADOWRIDGE DR SUITE 211 ORLANDO, FLORIDA 32812 EF20000890 co z� QW I > � ®J rr U -> 0 ozi O AJC) 0 LL- LLJ U) z VJ co o G. O U wW 5;Z wO CC U 0 0 U_ U_ zl T V UJ D� Oa co J 8 o CO CO LU o 0 C/) o c�� DRAWN BY; WJM CHECKED BY: ISSUE DATE: 06.18.2018 PROJECT #: 173-17043-12 COPYRIGHT: JOHNSON CONTROLS SYSTEM: FIRE ALARM SYSTEM SHEET: GENERAL NOTES & LEGENDS FA1 00 v 0 c 0 E �2 T � t'_ t �T r� c e m go` c� ` on c 01' `om .2 RM T c on T N EM 0y ro O o , YI .- r= m ya of x o cw d% N L ,p L � O a� 'o w� 'v c L -°7 ;4 a U o•_ Ev v ca c t5 o� c ; L ro oL u +' Ew 011 � c t; o" u 0, do -m c� a� Cy of by Y N c o� v E' d s� rs c� v= 'o :Fy E� c 02 E� `oo Li m= v� �y `o �r u c E Com" C 2 o� wu � N °o anv ,72 �y �o o u o`o _E y V Ycoo Lw o� v`c �v r a c ro •� 3 o= u c� vw �c 0 ON woU .- Z ° Z � Q u� �a 24° x 36" - AHUH U 51LE LA61 HHIN t EU: LAST SAVED BY: FILE PATH: E:\ACRD\Master Tyco Drawings\01-Toro Company\State, City\TY-Security Systems\Drawings\20 Develoment-DD\180507 - DD01\TORO.dwg v L 0 0 �v C T a: i i Ta C C O O _T t N .^ ya c on � G o � v Z` c v .^ ao ov c m E0 a o a c E r u c �b �c o Y� N � l= N � L L i vJ � O a o �u cc t� �L ca ac A E of me oa E aci vv La o� C O T v� m€ `o e, c a o� v o E -• c� �v 00 T C a 'C C U; O f0 i m � m m v v� •� o JL U O N f0 a C C O N O t N Cd Oa i aT c v0 a E� v c +L' �a all aw �a c � '^ v o� c v u � •� o o v v� v� Lo r �- T oa o� VIq of a E .50 m v �y O Cc u OS O V p C O t c y T v m �a v� N T L C u � �a vy m4' 9 O C `a E � ++ L C a+ O w O O T Ea oE 58 `o v a � A `o on .. Ca C v A lE v`v La c L 03, C 3 � O � N � O .. a Y � W u � O r yr W 0 Oa "a r Z 0 O a� z� ao �a VPLEX LOOP TO ALL EXISTING SECURITY EQUIPMENT WITH NEW VPLEX INTERFACE DEVICES. REUSE EXISTING CABLE RISER DIAGRAM SCALE: NOT TO SCALE REUSE EXISTING CABLE 120 VAC T FH FIRE ALARM JONNECT TO THE IWIRE ZONES. 'LEX LOOP) Select Panel from_p_ultdown Iiat: Polling L.up(.A) ......,...., Auxlllanry Power A) battery C Panel Stamtlby glarm (mA) a FacilityInformation Enter Standbyand Alarm Times Factorpy Max/mum Panel Al—Output Location: Calculated Current Draw PowerBudget p Remove Unused Devices From Ust Battery Standby (hours): 24Account#: 1700 3 01 470 165 Calculated Bell Draw 16.1 Bell Power Budget External Bell Power Req'd (mA): 1700 1700 1000 2300 Alarm Duration (minutes): 5 lo.e Q Apply UL Power Limits? (Required to maintain UL Usting including Model: 0 086 201 Standb Bud et UL864) En sneer: Recommended Ext. UL Power RectV (mA): O Commercial Fire Installation Date: Battery (AH) O Commercial Burg Installetlon Select Panel from_p_ultdown Iiat: Polling L.up(.A) ......,...., Auxlllanry Power A) Alarm Auxiliary Powe,(.A) Panel Stamtlby glarm (mA) a ..o.. -. Ountpuf a ..a.. ,.. Ouatput (if d; ma Maximum Panel Standby Output Max/mum Panel Al—Output ,.,e. o�„n, y Supported by Panel Calculated Current Draw PowerBudget p Remove Unused Devices From Ust 128 35.7 52.3L250 1000 1700 3 01 470 165 Calculated Bell Draw 16.1 Bell Power Budget External Bell Power Req'd (mA): 1700 1700 1000 2300 34.4 Total Standby Total Alarm 0 086 201 Standb Bud et Alarm Budget ;uu.0 Ext. UL Power RectV (mA): Cora eu-our crevice(s) are nor supporrect Dy selacreQ panel How many Total Enter powered Standby (aux Alarm Total Polling Standby To al -,--a,KEYPADSIINTERFACES Quantity extarnany7 P-)Current(Aux) Polling Loop Loop Current Total Alarm Current Current Reaulred 2 WIRE & 4 WIRE SMOKE DETECTORS (except v lex How many Total ( P P Enter powered Standby(auxAl.—Total Polling Standby Total Exfemal Polling Loop detectors) Quanflty externally? pw) Current(Aux) Polling Loop Loop current Total Alarm Cument Current Required 7wa wbe smoke tletector curmnf is built info the panel budgola. These fields are included to help y.v oze a comp Iota equipment list. The line belowlndlcntes Ifnumberordetect—exceeds panel capacity, ori/the selected panel does not support 2 -wire snake daleclors. How many Total Enter powered Standby(eux Alarm Total Polling Standby Tofel Exfemal AUXILIARY POWERED DEVICES Quanf/ty externally? pwr) Currant (Aux) Polling Loop Loop Current total Alarm Current Current Required How any 12V NOTIFICATION DEVICES ON Enm Enter powered Standby (aux Alarm Toter Tofel Polling Standby Total Sounder Cunedtfrorn Patrol Total Sounder BELL OUTPUT#1 quantity externally? pwr) current (Aux) Polling Loop Loop Current Bell #1 Current (external) FRUIT, 12V NOTIFICATION DEVICES ON How many Total Total Sounder Enter powered Standby(aux Alarm Total Polling Standby Current from Pane( Total Sounder BELL OUTPUT #2 (IF USED) Quantity ext—fly? pwr) current (Aux) Polling Loop Loop Current 8.11 42 Current (external) t, r POWER CALCULATIONS SCALE: NOT TO SCALE L4" A :30" - HI flit I U JILL LAJ I rHnN ICL): LAS 15AVLU bY: t-ILE NA I H: E:\ACAD\Master Tyco Drawings\01-Toro Company\State, City\TY-Security System s\Drawings\2. 0 Develoment-DD\180507 - DD01\TORO,dwg l'f Johnson Controls JOHNSON CONTROLS 6830 SHADOWRIDGE DR SUITE 211 ORLANDO, FLORIDA 32812 000 890 M Z � r - Q W nj d. Q co W _� D ®J cr U 0 Oz� � OJ p ® w °C f— 2 0 W cn z Z o cQ I— o cY) z O °wCf) z 0 � O Cf) m m � LL LL 0 0 1- 12 75 Z � � 0CD co J0'd 'Co) LU 1co)(8) Y C/) � DRAWN BY: WJfvl CHECKED BY: ISSUE DATE: 06.18.2018 PROJECT #: 173-17043-12 COPYRIGHT: JOHNSON CONTROLS SYSTEM: FIRE ALARM SYSTEM SHEET: RISER DIAGRAM & BATTERY CALCULATIONS FA1 02