Loading...
HomeMy WebLinkAbout1015 W 1 St 18-3214 Overhang repair SFH10AMAGF=1n) FOR W6A=rF=R GENERAL NOTES 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND SHALL NOTIFY THE ARCHITECT OF ANY ERROR, INCONSISTENCY PRIOR TO BIDDING AND/OR PROCEEDING WITH THE WORK. 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE AND BECOME FAMILIAR WITH LOCAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED AND CORRELATE PERSONAL OBSERVATIONS WITH REQUIREMENTS OF THE CONTRACT DOCUMENTS. 3. THE CONTRACTOR IS TO HAVE INSPECTED THE SITE AND REVIEW ALL EXISTING CONSTRUCTION CONDITIONS PRIOR TO PRICING. FAILURE OF THE CONTRACTOR TO INSPECT EXISTING CONDITIONS SHALL IN NO WAY RELIEVE THE CONTRACTOR FROM ANY OBLIGATION WITH RESPECT TO HIS WORK. 4. THE CONTRACTOR IS TO BE THOROUGHLY FAMILIAR WITH THE PLANS, SPECIFICATIONS, AND DOCUMENTS. THE FAILURE OR OMISSION OF ANY CONTRACTOR TO EXAMINE ANY FORM, INSTRUMENT, OR DOCUMENT, SHALL IN NO WAY RELIEVE THE CONTRACTOR FROM ANY OBLIGATION WITH RESPECT TO HIS WORK. 5. THE CONTRACTOR SHALL AT ALL TIMES ENFORCE STRICT DISCIPLINE AND GOOD ORDER AMONG THE CONTRACTOR'S EMPLOYEES AND SHALL NOT EMPLOY ON THE WORK ANY UNFIT PERSON OR ANYONE NOT SKILLED IN THE TASK ASSIGNED THEM. 6. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE CONTRACTOR'S BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, AND I SHALL COORDINATE ALL PORTIONS OF THE WORK. 7. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, CODES, ORDINANCES, RULES, REGULATIONS AND LAWFUL y ORDERS OF ANY PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK. 8. THE ARCHITECT/OWNER RESERVES THE RIGHT TO REJECT ITEMS INCORPORATED INTO THE WORK, WHICH FAIL TO MEET THE SPECIFIED MINIMUM REQUIREMENTS. THE ARCHITECT FURTHER RESERVES THE RIGHT, AND WITH OUT PREJUDICE TO OTHER RECOURSE THE ARCHITECT MAY TAKE, TO ACCEPT NON -COMPLYING ITEMS SUBJECT TO AN ADJUSTMENT IN THE CONTRACT AMOUNT AS APPROVED BY THE ARCHITECT AND THE OWNER. 9 THE CONTRACTOR WARRANTS TO THE OWNER THAT ALL MATFRIALS AND EQUIPMENT FURNISHED UNDER THIS CONTRACT WILL BE NEW UNLESS OTHERWISE SPECIFIED, AND THAT ALL WORK WILL BE OF GOOD QUALITY, FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. ALL WORK NOT CONFORMING TO THESE REQUIREMENTS, INCLUDING SUBSTITUTIONS NOT PROPERLY APPROVED AND AUTHORIZED, MAY BE CONSIDERED DEFECTIVE. MATERIALS AND EQUIPMENT SPECIFIED FOR REUSE ARE TO BE PROPERLY CLEANED AND RECONDITIONED PRIOR TO REINSTALLATION. 10. IT IS THE INTENT OF THE PLANS AND SPECIFICATIONS TO PROVIDE A COMPLETE INSTALLATION, WHICH WILL OPERATE SATISFACTORILY. I ANY APPARATUS, APPLIANCE, MATERIAL, APPURTENANCE OR LABOR THAT MAY BE NECESSARY TO COMPLETE WORK IN ACCORDANCE WITH THE INTENT OR PURPOSE OF THESE PLANS SHALL BE FURNISHED AND INSTALLED, WITHOUT EXTRA COST, AS IF MENTIONED IN THE SPECIFICATIONS, OF SHOWN IN THE PLANS. 11. ALL DIMENSIONS INDICATED "CLR" TO BE MAINTAINED AS CLEAR FINISHED DIMENSIONS. 12. ALL PENETRATIONS IN FLOOR, ROOF OR WALLS ARE TO BE SEALED TO MAINTAIN STRUCTURAL, WATERPROOF, FIRE -RATING, AND FIREPROOFING INTEGRITY. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OF DAMAGE DONE TO PROPERTY BY PERSONS IN HIS EMPLOY OR IN THE EMPLOY OF HIS SUBCONTRACTORS. 14. PROTECT ALL WORK FROM DAMAGE THAT IS TO REMAIN IN PLACE. USE BARRICADES, TARPAULIN, TEMPORARY WALLS, PLYWOOD, PLANKING, MASKING, OR OTHER SUITABLE MEANS AND METHODS AS APPROVED. IF WORK TO REMAIN IN PLACE IS DAMAGED, RESTORE TO ORIGINAL CONDITION AT NO ADDITIONAL COST TO OWNER. 15. THE CONTRACTOR SHALL MAINTAIN THE PREMISES IN A CLEAN & ORDEPLY FASHION DURING THE ENTIRE CONSTRUCTION PERIOD, REMOVING ALL TRASH & DEBRIS AS REQUIRED, 16. CONTRACTOR TO REVIEW AND COORDINATE KEYING SYSTEM WITH OWNER AND PROVIDE TYPE REQUIRED (MASTER, GRAND- MASTER, OR GREAT -GRANDMASTER) INTEGRAL TO MATCH OWNER'S EXISTING SYSTEM, NO EXCEPTIONS. 17. MATCH ALL EXISTING FINISHES U.N.O. (INCLUDES FINISH HEIGHTS) 18. FIRE ALARM AND SMOKE DETECTION SYSTEMS SHALL ALWAYS BE ACTIVE. HEADS MAY BE COVERED DURING HOURS OF CONSTRUCTION BUT THE COVERS SHALL BE REMOVED AT THE END OF THE DAY. IF THIS IS IMPOSSIBLE, THEN INSTALL A FIRE WATCH UNTIL THESE SYSTEMS ARE ACTIVE 19. ALL THE AREAS UNDER DEMOLITION/CONSTRUCTION SHALL BE KEPT UNDER NEGATIVE PRESSURE RELATIVE TO THE SURROUNDING OCCUPIED AREAS. NEGATIVE PRESSURE SHALL BE MAINTAINED PRIOR TO ANY DEMOLITION/CONSTRUCTION WORK. A MANOMETER SHALL BE USED TO VERIFY PRESSURES AND A DAILY LOG SHALL BE MAINTAINED. Provide 2"x4"x3'-6" portion of wood for 20. THE EXISTING DUCT WORK BEING MODIFIED SHALL BE CLOSED DURING DEMOLITION/CONSTRUCTION. RETURN AIR INTAKES ARE TO BE new overhang attach to existing top CLOSED AND SEALED FOR THE DURATION OF CONSTRUCTION chord of truss w/ 16d nails @ 12" o.c. - .... . 1:,.1:11. «.«.:: 1111 New plywwod deck- singles - - 1.1__11 ---- ..............._......----..................... 1............ ..._..........._..__ & fascia shall be provided at GENERAL SPECIFICATIONS .6 e pan general notes) 1111.. __ ......j DESIGN PARAMETERS (See I & e s 1) -ALL WOOD SHAL BE (SYP) SOUTHDERM YELLOW GRADE 2 OR BETTER - 1111.- -- _ -_ __-_- . .. ..__-----._..........__..................._...._..........; 12 2) -ALL WOOD AGAINST CONCRETE SHOULD BE P.T. OR /AND HAVE PAPER i (Vult) Ultimate Design Wind Speed - FELT BETWEEN (TYP) (3 SECONDS GUST)----------------------------- 140 mph f 3 t 3) -PROVIDE WATER RESISTANT GYP.BACKING BD. OR GLASS MAT WATER (Vasd) Nominal design win speed -------------108 mph RESISTANT GYP. BACKING PANELS UP TO 4'-0" HEIGHT IN ALL WET WALL Wind Importance Factor -------------------------1,0 H2.5 Simpson hurricane ties E` AREAS OF THE RENOVATION BATHROOM & KITCHEN Building Risk Category ----------------------------II over each new 2"x4"x4'-0" �. 4) -ALL WOOD SHALL BE 8" MIN AWAY FROM FILLED GRADE Wind Exposure Category ------------------------- B Building Type ----------------------------------------Enclosed Internal Pressure ---------------------------------+/- 0.18 DESIGN & PARAMETERS SHALL CUMPLY W / FLORIDA BUILDING CODE 2017 6th EDITION & FRC 5) -ALL CONCRETE SHALL BE 3,000 PSI 6 -ALL CONCRETE IN CONTACT WITH THE FILL SHAL BE PROTECTED AGAINST TERMITE WITH POISON TREATED FILL 7) -ALL CONCRETE IN CONTACT WITH THE FILL SHALL BE PROVIDED W/6MILL VAPOR BARRIER LOAD REGUL ATIONS PERTABE 301.5 OF FBCR Attic without storage ---------------------------------10 psf Attic with limited storage--------------------------- 20 psf ' Guardrails and handrails ------------------------ 200 psf Guardrails in -fill components--------------------- 50 psf Rooms others than sleeping rooms------------- 40 psf Sleeping rooms--------------------------------------- 30 psf Stairs------------------------�---------------------------- 40 psf ............................................ _............................................................... ........................................... .................................................... ...................................... GENERAL DEMOLITION NOTES & STEPS NOTES: 1) -ALL WOOD SHALL BE SOUTHDERM YELLOW PINE (SYP) GRADE #2 OR BETTER 2) -ALL WOOD AGAINST CONCRETE SHOULD BE P.T. OR /AND HAVE PAPER FELT BETWEEN (TYP) 1)- PROVIDE PRIOR TO DEMOLITION OR ALTERATION "NOTICE OF ASBESTOS RENOVATION ORDEMOLITION" 2)- REMOVE THE EXIST. SHINGLES FROM THE AREA TO BE REPAIR 3)- REMOVE THE EXISTING DECK FROM THE AREA TO BE REPAIR 4) -PROCEED TO INSTALL THE REINFORCING COMPONENTS INDICATE IN THE SECTION 1/G11 5)- INSTALL THE NEW 1/2" PLYWOOD DECK (See schedule this sheet) & SHINGLES (per endorsed manufacturer Spec) 4" Pre -finish alum. flash (Drip edge) nailer to 2"x6" fascia w/ 1 "x3"coated nails 2"x6" fascia Vented soffit system 1/2" Plywood ---- 1/2" Wood siding � BATISTAMONTAERRAT INVInus U1U QDD�C���o1091 CONDOR PLACE WINTER SPRING FL / 32708 14 FLOOR PLAN G1.1 3/16" = V-0" ASPHALT ROOF SHINGLES OVER 1/2" STRUCTURAL PLYWOOD ON (2) UNDERLAYMENTS LAYERS OF A MINIMUM 19" WIDE STRIP FIRT LAYER OF UNDERLAYMENT ' FELT PARALLEL WITH AND STARTING AT THE EAVES AND 36" WIDE STRIP „ » SECOND LAYER STARTING AT THE EAVES OVERLAPPING 19" WIDE STRIP LAYER. [ ,. Exist. pre -engineering wood truss @ 24" o.c. I i I Truss layout is for reference only,fabricator Y - verify all shapes & dimmensions. Provided shop 1 I drawing signed & sealed by a florida register engineer prior to fabrication. Provide uplift I 2'- 0" information - 0 Provide 2'-0" of 1/2" plywood at opposite I side of truss with the 2"x4"portion of roof Overhang damaged - --- overhang. Attach plywood to top & bottom [ chord of truss w/10d nails @ 8" o.c. DETAILED SECTION. SCALE: 3/4" = V-0" 0 0 00 CM ZONE - USE 8d (2 1/2") RING -SHANK NAILS @ 8" CC ROOF DECK SHEATING ZONE USE 8d (2 1/2") RING -SHANK NAILS @ 6" CC EDGES AND 8" CC FIELD ZONE3 - USE 8d (2 1/2") RING -SHANK NAILS @ 4" CC GABLE EDGES, 6" CCOTHER EDGES AND 6" FIELD NAILING SCHEDULE OVERHANG TO BE REPAIR RECORD COPY REVIEWED FOR CODE COMPLIANCE PLANSEXAMINER �-Zo'Ig DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS « AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET G� ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, q'�7TAEN� CONSTRUCTION OR VIOLATIONS OF THIS CODE #18-321.4 LEE I• iii► r— 00 <( CCV L ry z LL O C'7 O LU I❑ E U) 11' W Z0 O N 0 0 i z U) p .W () I U)W n - I L N — v U I..L a) O 0,5 c� OiL L O cn� O L) Cn ® U/ " u 'E c� E a� FU E U) O i(D LU W ~ IUo � co .o �– 0U) WQ q Cl)o CL ao < 0 E Q LO N O m V) O �o a N r– my W = CD +� -O O CD CD O w U � :03co 0 m 0 - 0 C CD CD 0 o M o W I• I— r— 00 <( CCV ry LL C'7 O I❑ - 11' ❑ O 11 7 0 z U) ,� t6 .W () Q �❑ U)W - L N — z �� cn� ® 07 U U) ([T W>z ~ I— m Q o X00 0U) 0����zZ0 O W _ w _ W EY 0- = CD J c) J C) CD CD Job Number: 18-033 Date: 07-12-2018 Drawn: G.P. Checked: J.E.B. Title GENERAL NOTES PERIMETER HOUSE & DETAIL SHEET No OF Sheet