Loading...
HomeMy WebLinkAbout2650 W 25 St (NO PERMIT #-LETTER)P. A . William M. Baldwin, P.E. , GonsultingEngineer CEDARS EXECUTIVE CENTER - SUITE 250-B 2639 NORTH MONROE STREET TALLAHASSEE, FLORIDA 32303 January 7, 1985 TO: Mr. Harold Leslie 753 Old Dirt Road Tallahassee, Florida 32301 RE: Roof Deck TELEPHONE 904/386-3206 HOME 904/385-31 98 , The condition described by phone, hand crimped deck is the same as the deck tested in Miami about 5 years ago. The deck tests for uplift were run using only a handmade crimp at the hidden connector. The test results showed that the crimp would provide a connection which exceeded the limits of the test equipment. Tests were run at about 40 psf, which is the minimum acceptable per the South Florida Building Code. The single crimp at the connector is not sufficient to develop the deck shear. A minimum of two crimps between purlins is necessary to develop shear diaphram action. If a more detailed study is necessary, please advise me. Sincerely, WILLIAM M. BALDWIN, P.E. WMB/bb