Loading...
HomeMy WebLinkAbout103 Wilkins CirCITY OF SANFORD BAN '1 5 201$ BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Scoo Documented Construction Value: $ ?1dCK Job Address: as C t RZG (e- Historic District: Yes ❑ No ❑ Parcel ID: - 0-5Z Z- d G (D C)— o 2-0 Residential [Commercial ❑ Type of Work: New ❑ Addition ❑ Alteration Re air ❑ Demo L Change of Use ❑ Move ❑ YP f P g Description of Work: C_h i t ti1, Cr-(-, ��� FL< c_+eze Cam- & Poft C t✓ S *N d 64 Plan Review Contact Person: (_;� t (`_ 0 Q e i t4i;J Title: Phone: 6ol--5c- 1 L; 1 7�% Fax: Email: Property Owner Information Name _ l rw is Phone: Street: 2 5 242 IN E i< V w 4u Resident of property? City, State Zip: &Vo!p 3 2 O� n ' ,� Contractor Information / Name�i � iZ 1 L f- t ckW ' C�� P Phone: Street: 1( R-6cv4�i-n'- Fax: City, State Zip: )&i t M �e ?,q 2& F t- State License No.: IZ 13 110 4 c/ 4 Name: Street: City, St, Zip: Bonding Company: Address: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 1053 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date �Ignalure of Contractor/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Pri ntractor/Agent's Name Signature of Notary -State of Florida Date ANNETTE M BLAND Notary Public -State of Florida Corrrrissior " GG 170900 '•.<�—�`., A1y Co rr. Expires Jar 16.2C22 Contra R11 wn to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing[] Gas❑ Roof ❑ Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes ❑ No ❑ APPROVALS: ZONING: ENGINEERING: COMMENTS: # of Heads UTILITIES: FIRE: Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application We hereby submit specifications and estimates for: 1- Demo and remove outdoor meter can and small panel. 2- Provide and install new meter can. Approved by Duke or FPL 3- Provide and install wires rated for 150 amps from meter cane to the 150 amps main outdoor panel. 4- Provide and install 1 new 150 amps main breaker outdoor panel. 5- Upgrading riser wire rated for 150 amps. 6- Provide and install new wire rated 150 amps from outdoor panel to the panel inside patio. 7- Demo and remove the 2 Federal pacific panels in patio. 8- Provide upgrade and install 1 new 150 amps rated outdoor panel inside patio and combine the 2 panels as one. 9- Terminate all wires in panels. Provide and install new breakers matching existing circuits breakers and make code correction if necessary. 10- Provide and install 3-30 amps circuit breakers. 11- Provide and install 1- 40 amps circuit breakers. 12- Provide and install 2- 2 pole 20 amps circuit breakers. 13- Provide and install 12- 20 amps circuit breakers. 14- Provide and install new Ground fault/arc fault circuit breakers for the outlets with no ground. 15- Installed any breakers needed to complete the work and to correct double tap breakers. 16- Provide and install GFCI receptacle where requires and replace outlets that worn-out. 17- Checked and label panel. 18- Checked to ensure everything is working properly. 19- Pull permit from city of Sanford. Total Price: $ 2400.89 `mod t P&C ELECTRIC LLC 5452 Bracken Court Winter Park, FL 32792 Office/Cell#(407) 529-4138 ER13014942 PROPOSAL Proposal submittedto: Phone: 407-312-9056 Date: 01-21-2018 Jennifer Wagner Address: Job Name/Location 103 Wilkins Circle Repairs/Sanford Sanford, FL 32771 Note: All works will be done in a like man manner and according to code and electrical standards. Price above is for the line items list above, anything discovers or adding later is extras. All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to specifications submitted, per standard practices. Any alteration or deviation from above specifications involving extra Authorized Signature: costs will be executed only upon written orders, and will become an extra charge over and above the estimate. All Pierre Tido agreements contingent upon strikes, accidents, or delays beyond our control. Owner to tarty fire, tornado, and other necessary insurance. Our workers are fully covered by Workers Compensation Insurance. Note: This proposal may be withdrawn by us if not accepted within 30 days. Payment due upon completion Acceptance of Proposal - The above prices, specifications, and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. Date of acceptance: Signature: I SCPA Parcel View: 35-19-30-522-0000-0020 Page 1 of 2 1JANRWR Property Record Card P Parcel: 35-19-30-522-0000-0020 x��+acccxrvrYr�cartnn Property Address: 103 WILKINS CIR SANFORD, FL 32771-4122 Parcel 35-19-30-522-0000-0020 Owner ALLEYNE, DENNIS Property Address 103 WILKINS CIR SANFORD, FL 32771-4122 Mailing 2528 WEKIVA WALK WAY APOPKA, FL 32703-4844 Subdivision Name COUNTRY CLUB MANOR UNIT 3 Tax District S1-SANFORD DOR Use Code 01-SINGLE FAMILY Exemptions 2018 Working 2017 Certified Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value $54,618 $46,800 Depreciated EXFT Value $1,000 $1,000 Land Value (Market) $12,500 $12,500 Land Value Ag Just/Market Value *' $68,118 $60,300 Portability Adj Save Our Homes Adj $0 $17,360 Amendment 1 Adj - $0 - -- $0 - - P&G Adj - $0 $0 Assessed Value $68,118 $42,940 Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund $68,118 $0 $68,118 Schools _ $68,118 $0 $68,118 _ City Sanford $68,118 $0 $68,118 11 SJWM(Saint Johns Water Management) $68,118 $0 $68,118 County Bonds $68,118 $0 $68,118 Description Date Book Page Amount Qualified Vac/Imp WARRANTY DEED 8/1/2017 08976 1574 $90,000 Yes Improved CORRECTIVE DEED QUIT CLAIM DEED 8/1/2017 6-/-1/2017 08976 08929 1573 1503 1 $100 ` No $10,000 No Improved Improved WARRANTY DEED -�- E 6/1/1990 02198 0212 $47,500 Yes Improved ADMINISTRATIVE DEED TWARRANTY 1 7/1/1989 02090 0071 $100 No Improved DEED 1/1/1989----1 ;32 1� 278 $100 No Improved WARRANTY DEED 3/1/1986 7 121717 1995 $100 No Improved Method Frontage Depth Units Units Price Land Value LOT 0.00 0.00 1 $12,500.00 $12,500 http://parceldetail. scpafl.org/ParcelDetaillnfo.aspx?PID=3 5193O5220000002O 1 /25/2018