Loading...
HomeMy WebLinkAbout117 French AveI'77 i JAN 0 4 2018 CITY OIANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION LB°/:__._.. W� Application No: � � - L Documented Construl _41l10 : S Job Address: ZZ 7 /Llof19/; � A Historic District: YeS6 No ❑ Parcel ID: 7S ' 19 - _?0 -S-4 5- _ 0 j 09 � � %y � Residentialff"Commercial ❑ Type of Work: New ❑ Addition�a Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work:e_i4e � 1'1e Plan Review Contact Person: 71-4All �� ��%� Title: Phone: �(C(7- yoz- f362 Fax: Email: b D 1+3 vt 1) G�/1 Property Owner Information Name ��` G L� s�F,G Phone: Street:i62'0Resident of property? A 1 P rr City, State Zip,;,, �a� `�C+,,s'''z 72� /,, Contractor Information Name 4 l,� mac. 4 d 6- % b/0 R;' . ,4— S� W �'1 Phone: 0 �- 7�c� '73 Street: Fax: City, State Zip: [% C,17.e ,32 7 3 2 State License No.: e�"C oz_Z2 7 Name: Street: City, St, Zip: Architect/Engineer Information Phone: Fax: E-mail: Bonding Company: Mortgage Lender: Address: Address: n e-+ WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR .PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. J Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be, found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID N fez /., Signature of Contractor/Agent Date Print tractor/Agent's Name ,?AX�11O-ge�,,, ANNETTE BLAND c Notary Public - State of Florida N,` do Commission # GG 060623 of1F��P 1111 My Comm. Expires Jan 16, 2018 Confractorkfgerlt ersQk­v­m,n to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas❑ Roof ❑ Construction Type: Occupancy Use: Flood Zone: - Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads APPROVALS: ZONING: I-17r IS- UTILITIES: ENGINEERING: COMMENTS: FIRE: # of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application SCPA Parcel View: 25-19-30-5AG-0308-0100 Page 1 of 2 Property Record Card r7=a% DSO"'cFAParcel: 25-19-30-5AG-0308-0100 Owner: COM HOLDINGS LLC CAiU'Xx -(x)4"IJ Fl(7kOA Property Address: 117 FRENCH AVE SANFORD, FL 32771 Parcel information Parcel 2 5-19-30-5AG-0308-0100 Owner COM HOLDINGS LLC Property Address 117 FRENCH AVE SANFORD, FL 32771 Mailing Subdivision Name 117 S FRENCH AVE SANFORD, FL 32771 SANFORD TOWN OF Tax District S3-SANFORD-WATERFRONT REDVDST DOR Use Code Exemptions 0102-SINGLE FAMILY - SANFORD HISTORICAL DISTRICT Value Summary 2018 Working 2017 Certified Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value $41,909 $39,518 Depreciated EXFT Value Land Value (Market) $45,700 $45,700 Land Value Ag Just/Market Value'* $87,609 $85,218 Portability Adj Save Our Homes Adj $0 _ $0 Amendment 1 Adj $0 _.. -$0_ $0 _ P&G Adj $0 Assessed Value $87,609 $85,218 Tax Amount without SOH: $1,622.00 1 2017 Tax Bill Amount $1,622.00 Tax Estimator Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments Seminole County GIS http://parceldetail.scpafl.org/ParcelDetailInfo.aspx?PID=2519305AGO3080100 1/4/2018 M&B AIR SERVICE, LLC r 8 JAfV 0 1U1d LpY /I January 4, 2018 ATTENTION: ERIC LEACH COCA HOLDINGS LLC 386-747-3200 REFERENCE: 117 FRENCH AVE. SANFORD,FL, (WEST SIDE) M&B AIR SERVICE, LLC PROPOSES TO FURNISH THE MATERIAL AND LABOR NECESSARY TO COMPLETE THE ABOVE REFERENCED JOB. PLEASE NOTE TO FOLLOWING JOB QUALIFICATIONS: WORK SCOPE BASED ON JOB SITE VISIT & PLAN PROVIDED WORK SCOPE BASED ON CURRENT MECHANICAL CODE. AIR CONDITIONING UNITS ARE TO BE TEMPSTAR 14 SEER MODELS. 1- 2 TON AIR HANDLER FEM4X2400A 1- 2 TON HEAT PUMP CONDENSER N4H424GKB 1- 5KW HEAT STRIP 1- 2 STAGE DIGITAL THERMOSTAT LOW VOLTAGE WIRING TO UNITS. INSTALL NEW REFRIGERANT, CONDENSATE DRAIN LINES DUCT WORK, GRILLS & REGISTERS CITY PERMIT TOTAL: $5,200.00 1 YEAR WARRANTY LABOR 10 YEAR MANUFACTURE PARTS PAY SCHEDULE AS FOLLOWS 100% ON COMPLETION ROUGH IN AND CHANGE ORDERS MUST BE PAID IN FULL PRIOR TO START OF TRIM PAYMENTS ARE NET 15 DAYS AND CHANGE ORDERS NET 7 DAYS ANY ALTERATION OR DEVIATION FROM ABOVE SPECIFICATIONS INVOLVING EXTRA COSTS WILL BE EXECUTED ONLY UPON WRITTEN ORDERS AND WILL BECOME AN EXTRA CHARGE OVER AND ABOVE THE ESTIMATE. THIS PROPOSAL MAY WITHDRAWN BY US IF NOT ACCEPTED WITH IN 30 DAYS. BID PRICING SUBJECT TO CHANGE AFTER 120 DAYS, DUE TO RISING MATERIAL COST. THANK YOU FOR THE OPPORTUNITY TO QUOTE THIS PROJECT. IF YOU ARE IN AGREEMENT WITH THE QUALIFICATIONS, THE PROPOSAL COST, AND PAYMENTS TERMS. PLEASE SIGN BELOW AND RETURN TO AUTHORIZE WORK AND ACCEPTANCE OF OUR PROPOSAL. THANK YOU SINCERELY, APPROVED BY MARK 13OLTON DATE PO BOX 35 GENEVA FL_ 32732 407-402-9362 CAC043970 z5- c Leock 116117 2i3S nHV >M NI VM NVd 1NVON003S System Sizing Calculations m Summer Residential Load - Room by Room Component Details Erick J.Leach Project Title: F 117 South French Avenue Rooms 1-3 + Bath - 1102701B Sanford, FL 12/21 /2017 Reference City: Sanford, FL Temperature Difference: 20.OF(TMY3 99%) Humidity difference: 44gr. Type" Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len H t Gross Shaded Unshaded Shaded Unshaded 1 1 Clear 0.74, 0.98 B-L No N 1.3ft 1.0ft 15.2 0.0 15.2 25 25 383 Btuh 4 1 NFRC 0.30, 0.90 B-L No E 1.3ft 1.0ft 33.6 0.6 33.0 21 36 1213 Btuh Window Total 49 (sqft) 1596 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Frame - Wood - Ext 0.09 13.0/0.0 109.7 2.4 258 Btuh 2 Frame - Wood - Ext 0.09 13.0/0.0 134.8 2.4 317 Btuh 3 Frame - Wood - Ext 0.09 13.0/0.0 70.0 2.4 165 Btuh Wall Total 315 (sqft) 740 Btuh Doors Type Area (sqft) HTM Load 1 Wood - Exterior 20.0 14.3 285 Btuh Door Total 20 (sqft) 285 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Vented Attic/Light/Shingle 0,025 38.90.0 219.0 1.14 250 Btuh Ceiling Total 219 (sqft) 250 Btuh Floors Type R-Value Size HTM Load 1 Stem/Crawlsp(Carpet)(v) 19.0 219 (sqft) 0.8 170 Btuh Floor Total 219.0 (sqft) 170 Btuh Zone Envelope Subtotal: 3041 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.28 2190 0.35 11.7 Load 256 Btuh Internal gain Occupants Btuh/occupant Appliance 1 X 230 + 3400 Load 3630 Btuh Sensible Envelope Load: 6927 Btuh Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.236 1636 Btuh Sensible Zone Load 8563 Btuh lCom onent Loads for Room #2 Bathro m 1 p W a f,..' ,M°�a� _ Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 4 Frame - Wood - Ext 0.09 13.0/0.0 48.0 2.4 113 Btuh Wall Total 48 (sqft) 113 Btuh Type/Color/Surface U-Value R-Value Area(sqft) Load -Ceilings 2 Vented Attic/Light/Shingle 0.025 3840.0 49.0 1.14 56 Btuh Ceiling Total 49 (sqft) 56 Btuh Floors Type R-Value Size HTM Load 2 Stem/Crawlsp(v) 19.0 49 (sqft) 0.8 41 Btuh Floor TotalEnerinyGal sqft) 41 Btuh pj ige 1 Manual J Summer Calculations Residential Load - Component Details (continued) Erick J.Leach Project Title: Climate: FL_ORLANDO_SANFORD_AIRPOR 117 South French Avenue Rooms 1-3 + Bath - 1102701 B Sanford, FL 12/21 /2017 Zone Envelope Subtotal: 1 209 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.28 490 0.05 1.8 Load 39 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 0 Load 0 Btuh Sensible Envelope Load: 248 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Attic) (DGM of 0.236 59 Btuh Sensible Zone Load 307 Btuh Type" Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len H t Gross Shaded Unshaded Shaded Unshaded 2 1 Clear 0.74, 0.98 B-L No N 1.3ft 1.0ft 30.3 0.0 30.3 25 25 767 Btuh Window Total 30 (sqft) 767 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 5 Frame - Wood - Ext 0.09 13.010.0 119.7 2.4 281 Btuh Wall Total 120 (sqft) 281 Btuh Type/Color/Surface U-Value R-Value Area(sqft) HTM Load —Ceilings 3 Vented Attic/Light/Shingle 0.025 38.90.0 219.0 1.14 250 Btuh Ceiling Total 219 (sqft) 250 Btuh Floors Type R-Value Size HTM Load 3 Stem/Crawlsp(Carpet)(v) 19.0 219 (sqft) 0.8 170 Btuh Floor Total 219.0 (sqft) 170 Btuh Zone Envelope Subtotal: 1468 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load Natural 0.28 2190 0.13 4.4 97 Btuh Internal Occupants Btuh/occupant Appliance Load gain 1 X 230 + 0 230 Btuh Sensible Envelope Load: 1795 Btuh Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.236 424 Btuh Sensible Zone Load 2219 Btuh EnergyGauge® / USRCZB v5.1 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) Erick J.Leach Project Title: Climate: FL_ORLANDO_SANFORD_AIRPOR 117 South French Avenue Rooms 1-3 + Bath - 1102701 B Sanford, FL 12/21/2017 CoYrnponent Loads forRoom�#4 Room3� °S1ZlI'. a $ F Fm n�7 qua ni k. Type" Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross Shaded Unshaded Shaded Unshaded 3 1 Clear 0.74, 0.98 B-L No N 1.3ft 1.0ft 15.2 0.0 15.2 25 25 383 Btuh Window Total 15 (sgft) 383 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 6 Frame - Wood - Ext 0.09 13.0/0.0 150.0 2.4 353 Btuh 7 Frame - Wood - Ext 0.09 13.0/0.0 154.8 2.4 364 Btuh 8 Frame - Wood - Ext 0.09 13.0/0.0 120.0 2.4 282 Btuh Wall Total 425 (sgft) 999 Btuh Type/Color/Surface U-Value R-Value Area(sqft) HTM Load —Ceilings 4 Vented Attic/Light/Shingle 0.025 38.00.0 238.0 1.14 272 Btuh Ceiling Total 238 (sgft) 272 Btuh Floors Type R-Value Size HTM Load 4 Stem/CraWsp(Carpet)(v) 19.0 238(sgft) 0.8 184 Btuh Floor Total 238.0 (sqft) 184 Btuh Zone Envelope Subtotal: 1839 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load Natural 0.28 2380 0.47 15.7 345 Btuh Internal Occupants Btuh/occupant Appliance Load gain 1 X 230 + 0 230 Btuh Sensible Envelope Load: 2414 Btuh Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.236 570 Btuh Sensible Zone Load 2985 Btuh EnergyGauge® / USRCZB v5.1 Page 3 Manual J Summer Calculations Residential Load - Component Details (continued) Erick J.Leach Project Title: Climate:FL_ORLANDO_SANFORD_AIRPOR 117 South French Avenue Rooms 1-3 + Bath - 1102701 B Sanford, FL 12/21 /2017 �' - ,,Es� WHOLE HOUSTOTALS '" x Sensible Envelope Load All Zones 11385 Btuh Sensible Duct Load 2690 Btuh Total Sensible Zone Loads 14074 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 14074 Btuh Totals for Cooling Latent infiltration gain (for 44 gr. humidity difference) 1003 Btuh Latent ventilation gain 0 Btuh Latent duct gain 706 Btuh Latent occupant gain (3.0 people @ 200 Btuh per person) 600 Btuh Latent other gain 0 Btuh Latent total gain 2309 Btuh TOTAL GAIN 16383 Btuh � yt'X�.' �"' a � �,b.�Y� a t S�, ,� �� � 1� .� 1 � m � $ '� 2 £t '� � ^x `r w � �.��5. "7yy� �,✓ EQUIPMENT. Puri 1. Central Unit # 18000 Btuh *Key: Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U-Factor) (InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half(%)) (Omt - compass orientation) rGr g MRKURL .i EnergyGauge® / USRCZB v5.1 Page 4 Residential System Sizing Calculation Summary Erick J.Leach Project Title: 117 South French Avenue Rooms 1-3 + Bath - 11027016 Sanford, FL 12/21 /2017 Location for weather data: Sanford, FL - Defaults: Latitude(28.78) Altitude(89 ft.) Temp Range(M) Humidit data: Interior RH 50% Outdoor wet bulb 76F Humidity difference 44 r. Winter design temperature(TMY3 99%) 36 F Summer design temperature(TMY3 99%) 95 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 34 F Summer temperature difference 20 F Total heating load calculation 11318 Btuh Total cooling load calculation 16383 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 159.0 18000 Sensible (SHR = 0.77) 101.5 13860 Heat Pump + Auxiliary(O.OkW) 159.0 18000 Latent 179.3 4140 Total Electric Heat Pump) 109.9 18000 WINTER CALCULATIONS IA/infar Haafinn I and (fnr 77.ri cnftl Load component Load Window total 94 sgft 3049 Btuh Wall total 907 sgft 2737 Btuh Door total 20 sgft 313 Btuh Ceiling total 725 sgft 626 Btuh Floor total See detail report 954 Btuh Infiltration 45 cfm 1672 Btuh Duct loss 1968 Btuh Subtotal 11318 Btuh Ventilation 0 cfm 0 Btuh Summer Coolino Load (for 725 sgft Load component Load Window total 94 sgft 2746 Btuh Wall total 907 sgft 2133 Btuh Door total 20 sgft 285 Btuh Ceiling total 725 sgft 828 Btuh Floor total 564 Btuh Infiltration 34 cfm 738 Btuh Internal gain 4090 Btuh Duct gain 2690 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 14074 Btuh Latent gain(ducts) 706 Btuh Latent gain(infiltration) 1003 Btuh Latent gain(ventilation) 0 Btuh Latent gain(internal/occupants/other) 600 Btuh Total latent gain 2309 Btuh TOTAL HEAT GAIN 16383 Btuh QllCtS(2�.7"ia) M Infil.(14.8%} Ceilings(5.1%) Windo%vs(16.5°/a) Latent int(3.796j lnt Gain(25.0a%) EnergyGauge® System Sizing Jo A. f3&vvvv�a-, 8th Edition PREPARED BY:Southern Energy Evaluation Services qu DATE: EnergyGauge® / USRCZB v5.1 System Sizing Calculations - Winter Residential Load - Room by Room Component Details Erick J.Leach Project Title: 117 South French Avenue Rooms 1-3 + Bath - 1102701 B Sanford, FL Building Type: User 12/21 /2017 Reference City: Sanford, FL (Defaults) Winter Temperature Difference: 34.0 F (TMY3 99%) Component Loads for Room �.R Y aY 5^ k fi3 k Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 1, Clear Wood 0.98 N 15.2 33.3 505 Btuh 4 1, NFRC 0.30 Wood 0.90 E 33.6 30.6 1028 Btuh Window Total 48.8 s ft 1533 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame - Wood - Ext (0.089) 13.0/0.0 110 3.02 331 Btuh 2 Frame - Wood - Ext (0.089) 13.0/0.0 135 3.02 407 Btuh 3 Frame - Wood - Ext (0.089) 13.0/0.0 70 3.02 211 Btuh Wall Total 315 s ft 949 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Wood - Exterior, n (0.460) 20 15.6 313 Btuh Door Total 20 s ft 31313tuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Vented Attic/L/Shing (0.025) 38.0/0.0 219 0.9 189 Btuh Ceilinq Total 219 s ft 18913tuh Floors Type Ueff. R-Value Size X HTM= Load 1 Stem/C rawlsp (Carpet) (v) (0.049) 19.0/0.0 219.0 sqft 1.3 287 Btuh Floor Total 219 s ft 287 Btuh Room Envelope Subtotal: 3271 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.37 2190 0.35 15.5 580 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Attic) (DLM of 0.210) 810 Btuh Room #1 Sensible Room Subtotal 4661 Btuh x ;ComponentLoaiis for Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 4 Frame - Wood - Ext (0.089) 13.0/0.0 48 3.02 145 Btuh Wall Total 48 s ft 145 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 2 Vented Attic/L/Shing (0.025) 38.0/0.0 49 0.9 42 Btuh Ceilin Total 49 s ft 4213tuh Floors Type Ueff. R-Value Size X HTM= Load 2 Stem/Crawlsp(Tile)(v) (0.052) 19.0/0.0 49.0 sgft 1.4 69 Btuh Floor Total Ener Gau e® / USRCZB *1 SO 69 Btuh Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) Erick J.Leach Project Title: 117 South French Avenue Rooms 1-3 + Bath - 1102701B Sanford, FL Building Type: User 12/21 /2017 Room Envelope Subtotal: 256 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.37 490 0.05 2.4 88 Btuh Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DLM of 0.210) 72 Btuh Room #2 Sensible Room Subtotal 417 Btuh Window Panes/Type Frame U Orientation Area s ft X HTM= Load 2 1, Clear Wood 0.98 N 30.3 33.3 1011 Btuh Window Total 30.3 s ft 1011 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 5 Frame - Wood - Ext (0.089) 13.0/0.0 120 3.02 361 Btuh Wall Total 120 s ft 361 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 3 Vented Attic/L/Shing (0.025) 38.0/0.0 219 0.9 189 Btuh Ceiling Total 219 s ft 18913tuh Floors Type Ueff. R-Value Size X HTM= Load 3 Stem/Crawlsp(Carpet)(v) (0.049) 19.0/0.0 219.0 sgft 1.3 287 Btuh Floor Total 219 s ft 287 Btuh Room Envelope Subtotal: 1848 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.37 2190 0.13 5.9 221 Btuh Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DLM of 0.210) 435 Btuh Room #3 Sensible Room Subtotal 2603 Btuh EnergyGauge® / USRCZB v5.1 Page 2 Manual J Winter Calculations Residential Load - Component Details (continued) Erick J.Leach Project Title: 117 South French Avenue Rooms 1-3 + Bath - 1102701B Sanford, FL Building Type: User 12/21 /2017 Window Panes/Type Frame U Orientation Area s ft X HTM= Load 3 1, Clear Wood 0.98 N 15.2 33.3 505 Btuh Window Total 15.2 s ft 505 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 6 Frame - Wood - Ext (0.089) 13.0/0.0 150 3.02 453 Btuh 7 Frame - Wood - Ext (0.089) 13.0/0.0 155 3.02 467 Btuh 8 Frame - Wood - Ext (0.089) 13.0/0.0 120 3.02 362 Btuh Wall Total 425 s ft 1282 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 4 Vented Attic/L/Shing (0.025) 38.0/0.0 238 0.9 205 Btuh Ceilin Total 238 s ft 2056tuh Floors Type Ueff. R-Value Size X HTM= Load 4 Stem/Crawlsp(Carpet)(v) (0.049) 19.0/0.0 238.0 sqft 1.3 312 Btuh Floor Total 238 s ft 312 Btuh Room Envelope Subtotal: 2304 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.37 2380 0.47 21.0 783 Btuh Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DLM of 0.210) 650 Btuh Room #4 Sensible Room Subtotal 3737 Btuh Subtotal Sensible Heat Loss 11318 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 11318 Btuh EnergyGauge® / USRCZB v5.1 Page 3 Manual J Winter Calculations Residential Load -Component Details (continued) Erick J.Leach Project Title: 117 South French Avenue Rooms 1-3 + Bath - 1102701B Sanford, FL Building Type: User 12/21 /2017 1. Electric Heat Pump # 18000 Btuh Key: Window types - NFRC (Requires U-Factor and Shading coefficient(SHGC) of glass as numerical values) or - Glass as 'Clear' or'Tint' (Uses U-Factor and SHGC defaults) U - (Window U-Factor) HTM - (ManualJ Heat Transfer Multiplier) EnergyGauge® / USRCZB v5.1 Page 4 .FORMR405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*= 92 The lower theEnergyPerformance Index, the moreefficient the home. 1. New constructionor existing 2. Single familyor multiple family 3. Number of units, if multiple family 4. Numberof Bedrooms 5. Is this a worst case? 6. Conditionedfloor area(ft2) 7. Windows" Description a. U-Factor: Sgl, U=0.90 SHGC: SHGC=0.30 b. U-Factor: Sgl, default SHGC: Clear, default c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 117 South French Avenue, Sanford, FL, Existing (Projecte 9. Wall Types Insulation Area Single-family a. Frame- Wood, Exterior R=13.0 1021.30 ft2 b. N/A R= ff 1 c. N/A R= ff° 0 d. N/A R= ff, 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=38.0 725.00 ft2 725 b. N/A R= ff Area c. N/A R= ff 33.58 ft2 11. Ducts R ff a. Sup: Room 1, Ret: Room 1, AH: Room 6 149 60.67 ft2 12. Cooling systems k Btu/tr Efficiency ff'- a. Central Unit 18.0 SEER:14.00 8. Floor Types Insulation a. Crawlspace R=19.0 b. N/A R= c. N/A R= ff 13. Heating systems kBtu/tr Efficiency 1.333 ft. a. Electric Heat Pump 18.0 HSPF:8.20 0.622 Area 14. Hot water systems 725.00 ft2 a • E F: ff b. Conservation features ff 15. Credits CF I certify that this home haxomplied with the Florida Energy Efficiency Code folBuilding Constructionthrough the above energy saving features which will beinstalled (orexceeded) in this home before final inspection. Otherwise, a new EPL Display Cardwill becompleted based oninstalled Codecompliant features. BuilderSignature: Date: Address of NewHome: 117 South French Avenue City/FLZip: Sanford, FL "Note: This is not aBuilding Energy Rating. If yourindex isbelow 70, yourhome mayqualify forenergyefficient mortgage (EEM)incentives if youobtain a Florida EnergyGauge Rating. Contact theEnergyGauge Hotline at (321) 638-1492 or seetheEnergyGauge web site alenergygauge.com forinformation and a list ofcertified Raters. For information about the FloridaBuilding Code, Energy Conservation, contact the FloridaBuilding Commission's support staff. "Labelrequired bySection R303.1.3 of the FloridaBuilding Code, Energy Conservation, if not DEFAULT. 12/21/2017 11:07 AM EnergyGauge® USA- v5.1- Section R405.4.1 Compliant Software Page 1 of 1 FORMR405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department ofBusiness andProfessional Regulation -Residential Performance Method Project Name: Rooms 1-3+ Bath- 1102701E Builder Name: Owner Street: 117 South French Avenue Permit Office: City of Sanford City, State,Zip: Sanford , FL , Permit Number: Owner: Erick J.Leach Jurisdiction: 691500 Design Location: FL, Sanford County:: Seminole (Florida Climate Zone 2) 1. New constructionor existing Existing (Projecte 9. Wall Types(1021.3 sqft.) Insulation Area 2. Single familyor multiple family Single-family a. Frame- Wood, Exterior R=13.0 1021.30 ft2 b. N/A R= ff 3. Numberof units, if multiple family 1 c. N/A R= ff 4. Numberof Bedrooms 0 d. N/A R= ff 10. Ceiling Types(725.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=38.0 725.00 ft 2 6. Conditionedfloor area abovegrade(ft2) 725 b. N/A R= ff Conditioned floor area below grade (ft2) 0 c• N/A R= ff 11. Ducts R ff 7. Window(94.3 sqft.) Description Area a. Sup: Room 1, Ret: Room 1, AH: Room 6 149 a. U-Factor: S911 U=0.90 33.58 ft2 SHGC: SHGC=0.30 b. U-Factor: Sgl, default 60.67 ft2 12. Cooling systems k Btu/fr Efficiency SHGC: Clear, default a. Central Unit 18.0 SEER:14.00 c. U-Factor: N/A ff, SHGC: 13. Heating systems kBtu/tr Efficiency d. U-Factor: N/A ff a. Electric Heat Pump 18.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.622 14. Hot water systems 8. Floor Types (725.0 sqft.) Insulation Area a EF: 0.000 a. Crawlspace R=19.0 725.00 ft2 b. Conservation features b. N/A R= ff c. N/A R= ff 15. Credits CIF Glass/Floor Area: 0.130 Total Proposed Modified Loads: 27.65 C PASS TotalBaseline Loads: 29.97 6�1v�7 I herebycertify that the plans andspecifications covered by Reviewof the plans and VBE ST,g?' thiscalculation are incompliance with the FloridaEnergy Code. specifications covered by this calculation indicates k�~O°'� }a 40' ' Jo o ,�J , , A 13o Vv v�A '`'►" " compliance �fii ��• with the Florida Energy Code. PREPAREDBY: Southern Energy Evaluation Services Before construction iscompleted DATE: 12-21-17 this building will be inspected for compliance with Section 553.908 0 a I herebycertify that this building, as designed, is in compliance Florida Statutes. 5� CDDv with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: -Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. -Compliance requires an AirBarrier andinsulation Inspection Checklist in accordance with R402.4.1.1 andstarting July 1, 2017 thisproject requires anenvelope leakage testreport with envelope leakage no greater than 5.0 ACH50(R402.4.1.2). 12/21/2017 11:05 AM EnergyGauge® USA- v5.1- Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: Rooms 1-3+ Bath- 1102701 Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 725 Lot # Owner: Erick J.Leach Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Owner Rotate Angle: 0 Street: 117 South French Aven Permit Office: City of Sanford Cross Ventilation: County: Seminole Jurisdiction: 691500 Whole House Fan: City, State, Zip: Sanford , Family Type: Single-family FL , New/Existing: Existing (Projected) Comment: CLIMATE v IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Sanford FL_ORLANDO_SANFOR 2 39 93 70 75 677 44 Medium BLOCKS Number Name Area Volume 1 Block1 725 7250 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Room 1 219 2190 Yes 1 1 Yes Yes Yes 2 Bathroom 1 49 490 No 0 0 1 Yes Yes Yes 3 Room 2 219 2190 No 1 0 1 Yes Yes Yes 4 Room 3 238 2380 No 1 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Crawlspace Room 1 35 ft 0 219 ft2 19 0 0 1 2Crawlspace Bathroom 1 6 ft 0 49 ft2 19 1 0 0 3Crawlspace Room 2 15 ft 0 219 ft2 19 0 0 1 4Crawlspace Room 3 29 ft 0 238 ft2 19 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 785 ft2 150 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC RBS IRCC V # Type Ventilation Vent Ratio (1 in) Area 1 Full attic Vented 300 725 ft2 N N 12/21/2017 11:05 AM EnergyGauge® USA- v5.1- Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 . I I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Room 1 38 Blown 219 ft2 0.11 Wood 2 Under Attic (Vented) Bathroom 1 38 Blown 49 ft2 0.11 Wood 3 Under Attic (Vented) Room 2 38 Blown 219 ft2 0.11 Wood 4 Under Attic (Vented) Room 3 38 Blown 238 ft2 0.11 Wood WALLS Adjacent To INall Type_ Space Cavity Width Height Sheathing Framing Solar Below 1 E Exterior Frame - Wood Room 1 13 14.33 10 143.3 ft2 0 0.349999 0 2 N Exterior Frame - Wood Room 1 13 15 10 150.0 ft2 0 0.349999 0 3 S Exterior Frame - Wood Room 1 13 9 10 90.0 ft2 0 0.349999 0 4 E Exterior Frame - Wood Bathroom 1 13 6 8 48.0 ft2 0 0.349999 0 5 N Exterior Frame - Wood Room 2 13 15 10 150.0 ft2 0 0.349999 0 6 W Exterior Frame - Wood Room 3 13 15 10 150.0 ft2 0 0.349999 0 _ 7 N Exterior Frame - Wood Room 3 13 17 10 170.0 ft2 0 0.349999 0 _ 8 S Exterior Frame - Wood Room 3 13 12 10 120.0 ft2 0 0.349999 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Room 1 None .46 3 6.7 20 ft2 WINDOWS Orientation shownis the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 2 Wood Single (Clear) No 0.95 0.8 15.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 2 N 5 Wood Single (Clear) No 0.95 0.8 30.3 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 3 N 7 Wood Single (Clear) No 0.95 0.8 15.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 4 E 1 Wood Single (Tinted) Yes 0.9 0.3 33.6 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 EIA Eq A ACH ACH 50 1 Wholehouse Proposed CFM(50) .000318 604 33.16 62.36 .2319 4.9986 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 18 kBtu/hr 1 sys#1 12/21/2017 11:05 AM EnergyGauge® USA- v5.1- Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 14 18 kBtu/hr 540 cfm 0.77 1 sys#1 SOLAR HOT WATERSYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF ff° DUCTS V -- Supply-- --- Return-- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Room 1 6 149 ft2 Room 1 99 ft2 Default Leakage Room 1 (Default) (Default) 1 1 TEMPERATURES Programable ThermostatNone Ceiling Fans: CoolingJan �X� [[ Feb [[ Mar E A r f May [X Jun [X] Jul Au X Se [ Oct [ Nov Dec Heatin Jan [X� Feb [X� Mar Apr Jun [ ]Jul ay IM Au rj Sep [ Oct [X� Nov Dec Ventin [[ Jan [[ Feb [X Mar [X A r [ Ma Jun [ ] Jul E Aug [ Se [X Oct [X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 12/21/2017 11:05 AM EnergyGauge® USA- v5.1- Section R405.4.1 Compliant Software Page 4 of 4 PORjt� N CERTIFICATE OF APPROPRIATENESS HISTORIC PRESERVATION BOARD CITY OF SANFORD 300 S. Park Avenue Sanford, Florida 32771 407.688.5145 * www.sanfordfl.gov/HP THIS DOCUMENT MUST BE POSTED AT ALL TIMES UNTIL PROJECT IS COMPLETED. ISSUED TO: Eric Leach for 117 French Avenue Sanford, FL 32771 DATE ISSUED: January 17, 2018 DATE EXPIRES: June 18, 2018 BP# 18-381 Approved to install new A/C HVAC unit adjacent to north elevation of house, screened from view; may not be visible from the Right of Way. hw"-I-1 - Christine Dalton, AICP Historic Preservation Officer/Community Planner Please be advised it is the owner and/or agent's responsibility to notify staff of any potential changes from the approved COA that arise and obtain approval prior to commencing the changes. This Certificate of Appropriateness does not constitute final development approval. The applicant is responsible for obtaining all necessary permits and approvals from applicable departments before initiating development. IS A BUILDING PERMIT REQUIRED FOR THE ACTIVITY LISTED ABOVE? OYES ❑ NO Building Department Representative CITY OF 'Aa S,,kNFORD FLORIDA APPLICATION # FOR A CERTIFICATE OF APPOPRIATENESS Answer all the questions on this form and submit all required attachments. Incomplete applications will not be -reviewed. If you have questions about application requirements contact the Historic Preservation Officer at 407.688.6145 to ensure your application is complete. General Information Downtown Commercial Historic District[] Residential Historic District�ls this a retroactive request? Yes ❑ No Is this application filed in response to a Notice of Violation from the Co a Enforcement Department? Yes[] No Proposed improvements will affect the following elevations: North South ❑ East ❑ West ❑ Property Address: 117 S, %//'e/I r- h AW . 5 9ll c/ , �G 3 7 7/ Property Owner Information Print Name: _ �r/c. L ed f�o %d n 4 S Mailing Address: /17 5. F,-en c& A Phone: 366-7�7- '3 a 0-0 Email: CK t c-J-LEA Cff a &MA (L . Cd hit Signature: Applicant/Agent Information Print Name: fir'/C Le-Q Ck Mailing Address: _ ( (7 5 , F—!`enLA 46,V- 4 Phone: 386-7y7-3a6aEmail:6"Z/C�TL9-4r a 0-MIL., GDir Signature: BY SIGNING BELOW YOU ACKNOWLEDGE THAT A BUILDING PERMIT MAY BE REQUIRED FOR THE SCOPE OF WORK LISTED BELOW. YOU MUST CONTACT THE BUILDING DEPARTMENT TO DETERMINE IF A BUILDING PERMIT IS REQUIRED. FAILURE TO OBTAIN A BUILDING PERMIT WILL RESULT IN A STOP WORK ORDER, DOUBLE PERMIT FEES, AND POTENTIAL FINES. BY SIGNING BELOW, YOU ALSO ACKNOWLEDGE THAT THE INFORMATION CONTAINED IN THIS APPLICATION IS TRUE AND ACCURATE TO THE BEST OF YOUR KNOWLEDGE. hereby understand and agree to the above statements and will pay all city fees related to this application as required by the city's adopted Fee Resol tion. Signature: L� Date: ❑ Would you like to receive emails regarding Historic Preservation and Community Planning within your community? Description of proposed work Completely describe the entire scope of work, including changes in material and color, and methods that will be used to accomplish the proposed work. For large projects an itemized list is required. Use the reverse side if necessary. �n 5' /�e7% 17eLN AICI Q,- T On No rTk Sid/C� OF h0U5C� � cl. n cv% jC2/IG2 6e, Ai�J01 P.n V1yP w HISTORIC PRESERVATION BOARD • 300 N. Park Avenue • Sanford, Florida 32771 •407.688.5145 • www.sanfordfl.gov/HP L fy— S Z � N uU 1 q r aas nHv dM N1vM Nvd AHVON003S ^,� DEPARTMENTFIRE PERMIT NO. / f 4? (0 ISSUE DATE: CONTRACTOR: 11") a ri JOB ADDRESS: TYPE OF WORK: Building & Fire Prevention Division Residential Permit Card • Post this permit in a conspicuous location outside • Approved plans must be posted with permit for inspection Leave all work uncovered until inspected and approved Permit expires 6 months from date of issue or last approved inspection PROTECT FROM WEATHER BUILDING INSPECTION TYPE APPROVED REJECTED INSPECTOR ELECTRICAL INSPECTION TYPE APPROVED RFJF_C7ED INSPECTOR FOOTER INSPECTION ELECTRIC UNDERGROUND STEMWALL FOOTER/SLAB STEEL BOND FORMBOARD SURVEY T.U.G. / PRE POWER SLAB / MONO -SLAB ELECTRIC ROUGH LINTEL / TIE BEAM ELECTRIC FINAL SHEATHING - ROOF MECHANICAL INSPECTION 7TPE APPROVED REIECTED INSPECTOR SHEATHING - WALLS FRAME MECHANICAL ROUGH INSULATION ROUGH IN MECHANICAL FINAL DRYWALL/SHEETROCK PLUMBING INSPECTION 7TPE- APPROVED REJECTED INSPECTOR LATH INSPECTION FINAL STUCCO/SIDING UNDERGROUND ROUGH FIREWALL SCREW TUB SET FIREWALL FINAL SEWER INSULATION FINAL PLUMBING FINAL FINAL SFR GAS INSPECTIONS INSPECTION TYPE APPROVED REJECTED INSPECTOR ROOF INSPECTION 7TPE APPROVED RFJECTF_D INS'PFCTOR GAS UNDERGROUND PIPE ROOF DRY -IN GAS ROUGH -IN FINAL ROOF GAS FINAL MISCELLANEOUS / FINAL INSPECTIONS IN.S'TPCTION 7TPE APPROVED REJECTED INSPECTOR INSPECTION TYPE APPROVED REJECTED 1NS'1E0OR FINAL DEMO FINAL DOOR FINAL SOLAR PANELS FINAL WINDOW FINAL POOL SCREEN FINAL SCREEN ROOM FINAL UTILITY BUILDING FINAL BUILDING OTHER MOBILE HOME TIE -DOWN MOBILE HOME FINAL WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT, THERE MAY BE ADDITIONAL RESTRICTIONS APPLICABLE TO THIS PROPERTY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY, AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES OR FEDERAL AGENCIES FBC 105.3.3 REVISED: 4-17 Inspection Line: 407.792.6069 or 855.541.2112 TO SCHEDULE AN INSPECTION: • Dial 407.792.6069 or 855.541.2112 • Provide the items requested during the message • The type of inspection requested must be scheduled under the appropriate permit type • Follow the prompts *** To Schedule Fire Inspections: Please call 407.562.2786 *** PLEASE NOTE: Inspections scheduled by 5:00 p.m. will be conducted the next business day. If you experience difficulty, please call 407.688.5150 Monday - Thursday 7:30 am - 5:30 pm for assistance. AUTOMATED INSPECTION SYSTEM CODES BUILDING ELECTRICAL FOOTER 104 ELECTRIC UNDERGROUND 211 STEMWALL 102 FOOTER / SLAB STEEL BOND 221 FORMBOARD SURVEY 147 T.U.G. 216 SLAB / MONO -SLAB 103 PRE POWER FINAL 218 LINTEL / TIE BEAM 105 ELECTRIC ROUGH 212 SHEATHING - ROOF 106 ELECTRIC FINAL 213 MECHANICAL SHEATHING - WALLS 115 FRAME 109 MECHANICAL ROUGH 409 INSULATION ROUGH -IN 110 MECHANICAL FINAL 410 PLUMBING DRYWALL / SHEETROCK 131 LATH INSPECTION 132 UNDERGROUND ROUGH 322 FINAL STUCCO / SIDING 130 TUB SET 312 FIREWALL SCREW 120 SEWER 311 FIREWALL FINAL 143 PLUMBING FINAL 313 GAS INSULATION FINAL 113 FINAL SFR 138 GAS PIPING UNDERGROUND GAS ROUGH -IN 328 314 ROOF ROOF DRY -IN 116 GAS FINAL 315 FINAL ROOF III FINAL DEMO FINAL SOLAR PANELS FINAL POOL SCREEN FINAL UTILITY BUILDING MOBILE HOME TIE -DOWN Miscellaneous Notes: MISCELLANEOUS / FINAL INSPECTIONS 126 FINAL DOOR 136 134 FINAL WINDOW 137 139 FINAL SCREEN STRUCTURE 127 124 FINAL BUILDING - OTHER 112 145 MOBILE HOME BUILDING FINAL 146 REVISED: 4-17 Inspection Line: 407.792.6069 or 855.541.2112 CERTIFICATE OF APPROPRIATENESS HISTORIC PRESERVATION BOARD CITY OF SANFORD 300 S. Park Avenue Sanford, Florida 32771 407.688.5145 • www.sanfordfl.gov/HP lgov/H P/H P THIS DOCUMENT MUST BE POSTED AT ALL TIMES UNTIL PROJECT IS COMPLETED. s ISSUED TO: DATE ISSUED: Eric Leach January 17, 2018 for 117 French Avenue DATE EXPIRES: Sanford, FL 32771 June 18, 2018 BP# 18-381 Approved to install new A/C HVAC unit adjacent to north elevation of house, screened from view; may not be visible from the Right of Way. Christine Dalton, AICP Historic Preservation Officer/Community Planner Please be advised it is the owner and/or agent's responsibility to notify staff of any potential changes from the approved COA that arise and obtain approval prior to commencing the changes. This Certificate of Appropriateness does not constitute final development approval. The applicant is responsible for obtaining all necessary permits and approvals from applicable departments before initiating development. IS A BUILDING PERMIT REQUIRED FOR THE ACTIVITY LISTED ABOVE? [YES ❑ NO Building Department Representative CITY OF SkNFORD FLORIDA APPLICATION # ?S !3 FOR A CERTIFICATE OF APPOPRIATENESS Answer all the questions on this form and submit all required attachments. Incomplete applications will not . be reviewed. If you have questions about application requirements contact the Historic Preservation Officer at 407.688.5145 to ensure your application is complete. General Information Downtown Commercial Historic District[] Residential Historic DistrictE�ls this a retroactive request? Yes❑ Is this application filed in response to a Notice of Violation from the Code Enforcement Department? Yes[] Noe Proposed improvements will affect the following elevations: North South ❑ East ❑ West ❑ Property Address: _ 1 /7 %-/ ez/ c 7 %� Property Owner Information Print Name: �r�%c; LPac1L. C.�m >40131 Mailing Address: / /7 s. F/-c:n GIB Phone: 386-7(-/7` 33 Z U Email: ER r C-- 5L-E,q Cf((Z-�, GYj b /L . CtI M Signature: Applicant/Agent Information Print Name: _ E;:-;G I-e Q Ck Mailing Address: ((7 S , -!`e-nd1t 47 4 Phone: 386-7YZ- 3�3Xd Email: 8/2,IG`7 LGH i2 (-Nh /L, Signature: BY SIGNING BELOW YOU ACKNOWLEDGE THAT A BUILDING PERMIT MAY BE REQUIRED FOR THE SCOPE OF WORK LISTED BELOW. YOU MUST CONTACT THE BUILDING DEPARTMENT TO DETERMINE IF A BUILDING PERMIT IS REQUIRED. FAILURE TO OBTAIN A BUILDING PERMIT WILL RESULT IN A STOP WORK ORDER, DOUBLE PERMIT FEES, AND POTENTIAL FINES. BY SIGNING BELOW, YOU ALSO ACKNOWLEDGE THAT THE INFORMATION CONTAINED IN THIS APPLICATION IS TRUE AND ACCURATE TO THE BEST OF YOUR KNOWLEDGE. hereby understand and agree to the above statements and will pay all city fees related to this application as required by the city's adopted Fee Resol tion. Signature: 0, Date: f L7 ❑ Would you like to receive emails regarding Historic Preservation and Community Planning within your community? Description of proposed work Completely describe the entire scope of work, including changes in material and color, and methods that will be used to accomplish the proposed work. For large projects an itemized )list is required. Use the reverse side if necessary. _Z:_15"40// /I!?t� A& 0171-T On /�U �`��1 s�o�� 07C haU5C HISTORIC PRESERVATION BOARD • 300 N. Park Avenue • Sanford, Florida 32771 •407.688.5145 • www.sanfordfl.gov/HP a o N o oa r 83s nHV W N-W \\\ NVd K'dVON003S �,��J