HomeMy WebLinkAbout128 Gleason CoveCITY OF SANFORD
BUILDING & FIRE PREVENTION
E �� IPERMIT APPLICATION
F B O 7 2018 Application No: Ig— %
BY: 5,275.00
Documented Construction Value. $
Job Address: 128 GLEASON COVE, SANFORD FL 32773 Historic District: Yes ❑ No ❑
Parcel ID: 02-20-30-523-0000-1140 Residential Q Commercial ❑
Type of Work: New ❑ Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑
Description of Work: REMOVE AND REPLACE ROOF WITH SHINGLES
Plan Review Contact Person: Title:
Phone:
Fax:
Email:
Property Owner Information
Name JUAN FERNANDEZ JR I Phone: (321) 262-6717
Street: 128 GLEASON COVE
City, State Zip: SANFORD FL 32773
Resident of property? : YES
Contractor Information
Name PRO ROOFING & ASSOCIATES, INC Phone: 407-542-5903
Street: 3024 KANANAWOOD CT STE 1008
City, State Zip: OVIEDO , FL 32765
Name:
Street:
City, St, Zip:
Bonding Company:
Address:
Fax: 407-542-8790
State License No.: CCC1328416
Arch itectlEngineer Information
Phone:
Fax:
E-mail:
Mortgage Lender:
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code, in effect.as of that date: 5"h Edition (2014) Florida Buildi Code ?A
Revised: June 30, 2015 Permit Application ��
NOTICE: In addition to the requirements of this'permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in complian ith plicable laws regulating construction and zoning.
SigoaftireXOWYA Date Signature of Contractor/Agent Date
Print
S
OZIEL HERNANDEZ
E Notary Public - State of Florida
Commission # FF 990343
My Comm. Expires May 9, 2020
Owner/Agent is Personally Known to Me or
Produced ID Type of ID t—
ELME
Print Conte
MPOS
Name
Si atuFe of Notary-St'at f Fjwprd ft,,, A"
° a 021EL HERNANDEZ
,2+1.�:
v� Notary Public . State of Florida :N
* Commission # FF 990343
yl a•;
'o;oFF o. My Comm. Ex Tres Ma p y 9, 2020
Contractor/Agent iS4 Personally Known to e or
Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing[] Gas❑ Roof ❑
Construction Type: Occupancy Use: Flood Zone: -
Total Sq Ft of Bldg:
Min. Occupancy Load:
New Construction: Electric - # of Amps
# of Stories:
Plumbing - # of Fixtures
Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads Fire Alarm Permit: Yes ❑ No ❑
APPROVALS: ZONING:
ENGINEERING:
COMMENTS:
UTILITIES:
FIRE:
WASTE WATER:
BUILDING:
Revised: June 30, 2015 Permit Application
SEMINOLE COUNTY and/or CITY OF SANFORD
DATE: 2/5/2018
I hereby name and appoint: �O!SA H-' E>- fos',t
an agent of: PRO ROOFING & ASSOCIATES, INC.
(Name of Company)
to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all
things necessary to this appointment for (check only one option):
❑ All permits and applications submitted by this contractor.
VThe specific permit and application for work located at:
128 GLEASON COVE, SANFORD, FL 32773
(job Site Address)
Expiration Date for This Limited Power of Attorney: DECEMBER 31 2018
License Holder: ELMER A. CAMPOS
State License #:
CCC1328416
Signature of License Holder:
State of Florida
County of SEMINOLE
The foregoing instrument was acknowledged before me this S day of Y� 20
by ELMER A. CAMPOS who is personally known to me and did not take an oath.
WITNESS my hand and official seal this -57
AofNotary
Signublic — State of Florida
OZiEL HERNANDEZ
Notary Public - State of Florida
^o;
Commission # FF 990343
o My Comm. Expires May 9, 2020
NOTARY SEAL
day of 20 hS ,
r► i
(Printed Name.)
Commission No. FF ':T% 03`Vt
State of FL. County of SEMINOLE
My Commission expires: $ ��
Rev.12/13
111111111111111111 dill 1111111111111 fill fill
GRANT MALOY7 SEMINOLE COUNTY
CLERK OF CIRCUIT COURT & COMMOLLCR
Permit Number: BK 9071 Fg 405
Folio/Parcel Identification Number: 02-20-30-523-0000-1140 CLERK'S g 2018014474
Prepared by: IDELAYDIS CAMPOS RECORDED 02/07/201vu 02:07:31 PM
Return to: PRO ROOFING & ASSOCIATES, INC. RECORDING FEES $10.00
3024 KANANWOOD COURT, SUITE 1008, OVIEDO FL 32765 RECORDED BY hdevare
NOTICE OF COMMENCEMENT
State of Florida, County of SEMINOLE
The undersigned hereby gives notice that improvement(s) will be made to certain real property, and in accordance with Chapter 713,
Florida Statutes, the followin information is provided in this Notice of Commencement.
1. Description of property flegal description of the property, and street address if available)
PLACID WOODS PH 2 LOT 114. 128 GLEASON COVE, SANFORD. FL 32773
2. General description of improvement(s)
REMOVE AND REPLACE ROOF WITH SHINGLES
3. Owner information
Name: jUAN FERNANDEZ JR Interest in Property OWNER__
Address128 GLEASON COVE, SANFORD, FL 32773
4. Fee Simple title Holder (if other than owner shown above)
Name: N/A Telephone Number:
Address
5. Contractor
Name: PRO ROOFING & ASSOCIATES. INC.
Telephone Number: .407-542-5903 - -----
Address 3024 IKANANWOOD_ COURT, SUITE 1008, OVIEDO FL 32765
6. Surety (if any)
Name: ----N/A- Telephone Number:
Address -__-Amount of bond $
7. Lender (if any)
Name: Telephone Number:
Address N/A ------ ...... ....
8. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as
provided by §713.13(1)(a)7, Florida Statutes.
Name: _N/A_ ----- - Telephone Number:
Address
9. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as
provided in §713.13(1)(b), Florida Statutes.
Name: N/A Telephone Number:
Address
10. Expiration date of notice of commencement (the expiration date is one year from the date of recording unless a
different date is specified) - -----
---
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Verification pursuant to Sec *or' 21, Florida Statutes: Under penalties of perjury, I declare that I have read the foregoing and that the facts stated
5
w R
in it are true to the b-ogrotimv kn�owg and belief.
Signatory "fo"M!t
Authorized Office r/QOctor/Pa rtner/M a nager §713.13[i][d])
This document was acknowledged before me this day of 2018 by
who is persona I ly_known or produced 6--6h L as identification.
tt- --�'
Sign ure of NItary Public — StRA
A K"6
$11m
V
OZIEL HERNANDEZ
Notary Public - State of Florida
Commission # FF 990343
MY COMM. Expires May 9. 2020 1
0EPU_1Y CLEIR
mum", 0,
ROD IFl"[i to
,
DONE RIGHT I RAIN TIGHT, GUARANTEED
Certifie PREFERRED
oflmaoii
3024 Kananwood Cit., #1008
Oviedo'
viedo FL. 32765
P.407-542-590r3 F.407-542-8790
PROPERTY ADDRESS
JUAN FERNANDEZJR
128 GLEASON COVE
SANFORD, FL 32773
County: SEMINOLE
ROOF TEAR -OFF:
1 Layer Shingles
Single Ply Flat Roof
Felt Underlayment
2 Layer Shingles
Gravel Roof
Other
�LLL
>RMSM�.. W Lkir,1L� ..
LL LL
LZ
FL. ROOFING CONTRACTOR I #CCC1328416
h
r
•9Q��®C�
VISA
888-8 B,p 7-6787
10752 Deerwood Park Blvd., #100
Jacksonville, FL. 32256
www.cfproroofing.com P.904-394-2959 F.904-394-8383
WOOD REPAIR: Customer Approval:
Inspect Roof Deck for Damaged Sheathing
Re -Nail Entire Roof Deck Up -To Code
Plywood sheathing replaced at $45.00 per sheet.
❑� Truss, fascia and wood boards will be replaced at
5.00 per linear foot.
Other:
FLAT ROOF SYSTEM:
❑ Torch Down Single Ply ❑ 75 Ibs Fiberglass Underlayment
COLD SYSTEM: El Self Adhered Modified Bitumen Roofing System
❑ Peel & Stick Underlayment ❑ Fiberglass Reinforced Felt
TAPERED SYSTEM:
BISO Cold Polyisocyanurate Roof Insulation
ISO Plus Composite Polyisocyanurate/Perlite Roof Insulation
NEW ROOF FLASHINGS:
16" Flashing on: ❑ Roof Valley(s) ❑ Flat Roof Pitch Change
Plumbing Vent Boots: 1.5" 2" 2 3" 1 4"
❑ Boot Guards Color:
Gooseneck Vents 4" 2 6" _ 10" _Color:
NEW GALVANIZED DRIP EDGE:
0 21/2 inch Face installed around entire perimeter of roof
❑ Other: Color:
ALUMINUM SEAMLESS GUTTERS:
❑ Aluminum Seamless Gutters ❑ Gutters Included In Price
Gutter Price Quote:
Gutter Feet: Down Spouts:
Additional Gutters will be: per linear foot.
Additional Downspout will be : each.
PROPOSAL NOTES:
This proposal is for a Limited Lifetime Architectural shingle, rated at 130 MPH. We propo.
flashing and damaged wood, wood'repairs price is listed above . A 5 layer protection cyst
Stick" felt on all places checked below. A fiberglass reinforced felt, "Peel & Stick" will be L
+; PROPOSAL NUM: -PRO-77255408654
Date: 12/26/2017
Phone: (321) 262-6717
Cell:
Email: JUAN01026@GMAIL.COM
ALUMINUM SOFFITS & FASCIA:
❑ Aluminum Fascia 8 Aluminum Soffit
❑ Fascia Incluced In Price Soffit Included in Price
❑ Eintire Roof Perimeter Soffit &Fascia Color:
Fascia 14alled Only On:
Soffit Installed Only On:
Price
ROOF VENTILATION:
❑ Aluminum Ridge Ven ft. Color:
❑d Baffled Shingle over Ridge Vent 25 ft.
Off -Ridge Vent(s): ' 8 4 ft. Qty: Color:
POWER VENT: 6 ft. Qty Color:
8 Electric Exhaust Fan: * City: Price:
Solar Powered -Exhaust Fan: Qty: Price:
*(Electrical work not included.)
CHIMNEY AREA.
El New flashing ❑ Replace existing flashing if needed.
❑ Build Chimney Cricket Price:
El Remove Chimney Price:
SKYLIGHTS:
❑ New Skylight ElReuse existing Skylight
2 x 2: _ Price: 1 4 x 2: — Price:
Other: Price:
E OF SKYLIGHT
Self Flashing B Curb Mounted
Insulated Glass Polycarbonate Dome
New skylight installations include interior work; wood frame,
dry wall, paint and labor. Labor charge: ea.
SOLAR TUNNEL:
❑ 10" Price:
❑ 22" Price: ❑ 14" Price:
BUILDING JURISDICTION: W County ❑ City
HOME OWNERS ASSOCIATION REQUIREMENTS:
❑ YES ❑ NO Contact:
1
e to tear -off your old roof to the wood deck and replace all vents, lead boots,
!m is used arouhdlperipherals penetrating your roof deck including a "Peel &
sed which is stronger than a 30 lb felt. All taxes and permiting fees are included.
Weatherproof with "Peel & Stick" in the
following areas:
' Eves Chimney Area
Roof Valleys Skylights
d Vent Pipes Low Slopes
Kitchen & Bath Vents Wall Flashing
El Other:
4� ENTIRE ROOF DECK RENAILED
Packet Total:
a Gold Package Total $5 275.0Q
Pro Roofing & Associates, Inc. will clean roof debris from gutters in addition to magnetically sweep entire perimeter of job site. All roofing debris will be hauled away and is
included as part of our service. All materials are guaranteed as specified. We will obtain all city or county permits necessary for the completion of the job. All work will be
completed according to standard roofing practices and current building codes. Any alteration or,deviation from above specifications involving extra costs will be executed
only upon written order and will become an extra charge item over and above this agreement. Any leaks occurring during the warranty period will be repaired per our
written warranty. This proposal may be withdrawn by us if not accepted within 15 days.
ACCEPTANCE OF PROPOSAL
The above specifications, prices and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will
be made as outlined herein. If payment is not received within 5 business days, after completion of job there will be a 3% late fee added to the balance
due. Any payment recieved by a credit card is subject to a convienence fee.
Payment Schedule n Completion Start Date: Completion Date:
ELMER CAMPOS 1212612017
uth riz gnature Date Pro Roofing & Associates Date
Y
f�
f
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Emall •
Quality Assurance Representative
Address/Phone/Email '
CertainTeed Corporation -Roofing
20 Moores Road
Malvern, PA 19355
(610)893-5400
mark.d.harner@saint-gobain.com
Mark Hamer
mark.d.harner@satnt-gobafn.com
Mark D, Hamer
18 Moores Road
Malvern, PA 19355.,.
(610) 651-5847 -
Mark, D.Harner@sa,int-gobain.com
Category
Roofing
Subcategory
Asphalt Shingles
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professlonal Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nleminen
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
03/09/2020
Validated By
John W. Knezevtch, PE
,,eValldatlon Checklist - Hardcopy Received
Certificate of Independence
Ft 5444 R12 CON 2017 01 C0,1 Menilnen oaf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D3161
2016
ASTM D3462
2010
ASTM D7158
2011
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Valldated
Date Pending FBC Approval
Date Approved
Date Revlsed
Summary of Products
Method 1 Option D
09/07/2017
09/12/2017
09/15/2017
12/12/2017
01/24/2018
FL #
Model, Number or Name
Description
5444.1
CertalnTeed Asphalt Roof Shingles
3-tab, 4-tab, strip (no -cut-outs), laminated and architectural
asphalt roof shingles
Limits of Use
Installation Instructions
Approved.for use In HVHZ; No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER Section 5 for Limits of Use
FL5444 R12 Ix_ 24 $ 1A1. .R CEMiNTEE12 ASPHALT .
f N ES i 1"�444-R12.odf
Verified By: Robert Nleminen, PE PE-59166
Created by Independent Third Party: Yes
Evaluation Reports.
FL 444 t2S2` 4E 320j7 05 FINAL r:_ft__aRjAjNT= A5PHALI
St�iN LES f"La444-R12 gdf ,.
Created by Independent Third Party: Yes_
hack Next
Contact Us :: 7661' 61( Slonc h ��tl. I'ptloh tdse1`L %3 399 Ph'onc,• 65GAV-18m
' The State of Florida Is an AA/EEo employer. ht2 7.7.019 Srp,�cgf Fkiritia.:: krivacy1 tnmul :: AccessiblIftY Stater"at :: Refund Statement
under Florida law, email addresses are public records. if you do not want your a -mall address released In response bo a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If.you have any questions, please contact 850.487.1395. *Pursuant to Section
455,275(1), Florida Statutes, effective October 1,.2012, licensees licensed under Chapter 455,.F,S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a persona(
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F,S.,
please dick here.. .. . _. .
.. Product Approval Accepts:
9912
Credit Card
Safe
`,[�RINITYIERD
EVALUATION REPORT
EXTERIOR RESEARCH & DESIGN, LLC.
Certiflcote of Autharizotion 1/9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203) 262-9245
CertainTeed Corporation Evaluation Report 3532.09.05-1113
20 Moores Road FL5444-R12
Malvern, PA 19355 Date of Issuance: 09/22/2005
(610) 651-5847 Revision 23: 09/05/2017
SCOPE:
This .Evaluation Report Is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: CertainTeed Asphalt Roof Shingles.
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein
and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityjERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.'
ADVERTISEMENT: The Evaluation Report -number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of -the Evaluation Report Is displayed, then it shall, be done in Its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
'distributors and shall be available for inspection at the Job site at the request of the Building Official. -
This Evaluation Report conslsts of pages 1 through 12.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nleminen,
P.E on 09/05/2017. This does not serve as an alectronlally signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nleminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code, evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which'this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained
specifically for that purpose.
r
`.-,- TRINHY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE;
Product Category:
Roofing
Sub -Category:
Asphalt Shingles
Compliance Statement:
CertainTeed. Asphalt Roof
Shingles, as .produced
by CertainTeed Corporation, have
demonstrated compliance with the following sections of
the eh Edition (2017) Florida Building Code and 6th Edition
(2017) Florida Building
Code, Residential Volume through
testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
standard.
Year-
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2010
1507.2.7.1, R90S.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2011
3. REFERENCES:
Kftfty
Examination
Reference
Date.
UL (TST 1740)
ASTM D3161
94NK9632
05/15/1998
UL (TST 1740)
ASTM D3161
99NK26506
11/23/1999
UL (TST 1740)
ASTM D3161
03CA12702
05/27/2003
UL (TST 1740)
ASTM D3161
03CA12702
06/16/2003 -
UL(TST 1740)
ASTM D3161
03NK29847
10/03/2003
UL (TST 1740)
ASTM D3161
04CA11329
05/24/2004 ^
UL (TST 1740)
ASTM D3161
04CA32986
12/03/2004
UL (TST 1740)
ASTM D3161
05NK07049
04/15/2005
UL (TST. 1740)
ASTM 03161
05NK16778
05/12/2005
UL (TST 1740)
ASTM D3161
05CA16778,,
05/12/2005
UL (TST 1740)
ASTM D3161
05NK14836
05/22/2005
UL(TST 1740)
ASTM D3161
OSNK22800
06/22/2005
UL(TST 1740)
ASTM 03462
R684
09/21/2005
UL•(TST 1740)
ASTM D7158
05NK08037
06/28/2006
UL (TST 1740)
ASTM D3161 & D3462
09CA28873
07/23/2009
UL(TST 1740)
ASTM D3462
10CA41303
10/07/2010
UL(TST 1740)
ASTM D3161
10CA41303
10/08/2010
UL(TST 1740)
ASTM D7158
IOCA41303
10/27/2010
UL(TST 1740)
ASTM D3161 & D3462
10CA44960
11/11/2010
ULLLC (TST 9628)
ASTM D3161, D3462 & 07158
13CA32897
11/21/2013
UL LLC (TST 9628)
ASTM 03161, D3462
TFWZ.R684
04/22/2014
UL LLC (TST 9628)
ASTM D7158 `
TGAH.11684
04/22/2014
ULLLC_ (TST 9628)
ASTM D3161 & D3462
4786334434
09/16/2014
UL LLC (TST 9628)
ASTM D3161 & D3462
4786570826
02/12/2015
ULLLC (TST 9628)
ASTM D3161, D3462 & D7158
4786570717
12/16/2015
UL LLC (TST 9628)
ASTM D3161 & D3462
4787195678
02/09/2016
UL LLC (TST 9628)
ASTM D3161, D3462 & D7158
4787390356
10/26/2016
UL LLC (TST 9628)
ASTM'D3462
4787380357
10/13/2016
ULLLC (TST 9628)
ASTM D7158
4787380357
11/08/2016
ULLLC (TST 9628)
ASTM D3161
4787380357
11/09/2016
UL LLC (TST 9628)
ASTM D3161, D3462 & D7158
4787586427
01/25/2017
UL LLC (QUA 9625)
Quality Control
Service Confirmation
Exp. 03/09/2020
Exterior Research and Design, I.M. Evaluation Report 3532.09.05-R13
Certlflcate of Authorizatlon #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-1112
CertainTeed Asphalt Roof Shingles; (610) 651.5847 Revislon 13:09/0512017
Page 2 of 12
`-J TRINITY ERD
4. PRODUCT DESCRIPTION:
4.1 ' CT20'", XT" 25, XT" 30 and XT'" 301R are fiberglass reinforced, 3-tab asphalt roof shingles.
4.2 Arcadia'", • Belmont®, Belmont® IR, Carriage House Shangle®, Grand Manor Shangle", Landmark-,
Landmark' IR;Landmark'"" 'Pro, Landmark'" Premium, Landmark'" TL, Landmark" Solaris and
Landmark"Solaris IR are fiberglass reinforced, laminated asphalt roof shingles.
•4.3 ` NorthGate'" is a fiberglass reinforced, laminated, S135 modified bitumen roof shingle.
4.4 Presidential Shake'", Presidential, Shake'" IR, Presidential Shake TL'" and Presidential Solaris'" are
fiberglass reinforced, architectural asphalt roof shingles.
4.5 Hatteras'", Highland Slate'" and Highland Slate' IR are fiberglass reinforced, 4-tab asphalt roof shingles.
4.6 Patriot'" is a fiberglass reinforced asphalt roof strip -shingle (with no cut-outs) providing a laminated
appearance through an intermittent shadow line with contrasting blend drops for color definition.
4.7 Presidential Accessory, Accessory for Hatteras, Shangle Ridge'"', Shadow Ridge'", Cedar Crest•", Cedar
Crest'" IR, NorthGate Ridge and NorthGate Accessory are fiberglass reinforced accessory shingles for hip
and ridge installation.
4.8 Any of the above listed shingles may be produced in AR (algae resistant) versions.
S. LIMITATIONS:
5:1
5.2
5.3
" '5.4
5.4.1
5.4.2
5.4.3
5.4.3.1
.5.5
This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, Is/was
used for permitting or design guidance unless retained specifically for that purpose.
-This Evaluation Report is not for use within FBC HVHZ jurisdictions. - - -
Fire Classification is not part of this Evaluation Report; refer"to'current Approved Roofing Materials
Directory for fire ratings of this product.
Wind Classification:
All shingles noted herein are Classified in accordance with FBC Tables-1507.2.7.1 and R905.2.6.1 to ASTM
D3161, Class•F and/or ASTM D7158,,Ciass H, Indicating the shingles are acceptable for us in all wind zones
up to V,,d = 150 mph (Vast = 194 mph). Refer to Section 6 for installation requirements to meet this wind
rating.
Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge, Cedar Crest, NorthGate Ridge
and NorthGate Accessory`hip & ridge -shingles have been evaluated in accordance with ASTM D3161, Class
F. All except NorthGate Ridge and NorthGate Accessory require use of BASF Sonolastic NP 1 adhesive or
Henkel PLO Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's application
instructions, for use in wind zones up to Vosd = 150 mph (Val, =194 mph).
Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required, for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
Analysis in accordance with ASTM D7158 indicates the measured uplift resistance (RT) for the CertainTeed
asphalt Roof shingles listed in Section 4.1 through 4.6 (except Presidential Solaris') exceeds the calculated
uplift force (FT) at a maximum design wind speed of V.d = 150 mph Wait = 194 mph) for residential
buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean
roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these
conditions using the Installation procedures detailed in this Evaluation Report and CertainTeed minimum
requirements, subject to minimum codified fastening requirements established within any local
jurisdiction, which shall take precedence.
All products in the roof assembly shall have quality assurance audits in accordance with F.A.C. Rule 61G20-
3.
Exterior Research and Design, I.I.C. Evaluation Report 3537..09.05-R13
Certificate ofAuthorl:atlon H9503 6"' EDITION (2017) FBC NON-HVHZ EVALUATION FL5444•R12
CertainTeed Asphalt Roof shingles; (610) 651-5847 Revision 13: 09/05/2017
Page 3 of 12
T�II�IIIYJERD
6. INSTALLATION;
6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 If R90S.2 and the shingle
manufacturer's minimum requirements.
6.1.1 Underlayment shall be acceptable to CertalnTeed Corporation and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or
R905.2.3.
6.2 Installation of asphalt shingles shall comply with the CertalnTeed Corporation current published
instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6
and the minimum requirements herein.
6.2.1- Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the "Steep Slope" directions.
6.3 CertalnTeed asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and CertalnTeed published installation instructions.
R 6.4 i 24"", kT"" 25XTT"' 3{ls XTr"' 30it
rf
LOW AND STANDARD SLOPE
ENGIISH 12" 12" 1T
305"nyn)=� -(3t)5 trim --�—{305 rirn}
1" (25 mm) — 11-t^ 1" (?shill)
5 s/e" (145 mro)
5 i1^k+'hSirmod
6.4.1
METRIC
t" (25 mm} Sealatit 1" (26 "'
F/gwa 113; Ussforornallsforevmfidiskin9fa
Usefonr naffs and six spots of asphalt roofing cement* for every Poll
shingle,(F1gnre 11-4). Asphalt ioofing cement meeting ASTM D4586
'rippe U is suggested,
apply l" (26 mn) spots of asphall roofing cement
under Each lab eornar.
Flgarell-4: Usefournal4 cmdsh spolsgfxPhdll rzn)rMIon daPsfopea
el:AUTION: Excessive use of roofing cement can cause shingles
to blister.
Hip & Ridtte for CT20T".. XT'" 25, XT'm 30, XT'''' 30.IR: Cut Shingles
t"") F' "I i" 2" (50 mm) Rtmova_
Cap .r Cap ca .— in)
Shingle Shingle Shingle Min
Flgum 1124, Oil hok, liars him back 10 nMko cap slri"As
(6nglltb dbaenslons shown).
flgru+r ll-2S.' /ruialln/Avn of txrpsalottg fGe hips and i!r'fgos..
6.4.1.1 For ASTM D3161, Class F performance use BASF "Sonolastic° NP1"' adheslve or Henkel "PL09 Polyurethane
Roof & Flashing Sealant", in accordance with CertalnTeed requirements.
Exterior Research and Design, LLC. t Evaluation Report 3532.09.05-R13
Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R12
CertalnTeed Asphalt Roof Shingles; (610) 651-5847 Revision 13: 09/05/2017
Page 4 of 12
6.5
6.5.1
LOW AND STANDARD SLOPE
Use SLX nails for et--eq hill shingle located as slwwn belotu
Figure 2: Uso sir malls, fnr viva fill sbiuglo.
�4TRINITY ERD
Use SIX nails and FOUR slxas of asphalt routing cement for every full
shingle us shown bdutP. Apply a.+pli;dl roafmg cement 1"(25 mui)
from edge of shingle. Asphalt roofing cement meeting ASYAI D 4586
type it is sngg". ed.
--.11�1'125um1 1'(2smN�l �+—
ftun j: Use Sir nits a,nd fanr SPOTS of mpbalf
roofing cenlotll oli $loopsloPis.
Hip & Ridse for Arcadia'14: Cedar Crest*"', Cedar Crest'" IR
Use two (2), minimum 11/4-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch
from each side edge and about 2-inch up from the starter shingle's exposed butt edge, ensuring minimum
-inch embedment into the deck, or full penetration through the deck. For each full Cedar Crest shingle,
place fasteners &5/8-inch up from its exposed butt edge and 1-inch from each side edge.
For ASTM 03161, Class F performance use BASF "Sonolastic® NPI"A" adhesive or Henkel "PL®
Polyurethane Roof & Flashing Sealant", In accordancewithCertalnTeed requirements, to hand -seal
Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the shingle's raised overlay on the
top piece and extending approximately 4. inch along the sides of the headlap along a line % to 1-inch from
each side of the shingle's headlap. Immediately align and apply the overlying shingle, gently pressing tab
sides into the adhesive, and install nails. To secure the other side, apply a 1-inch diameter spot of NP 1 or
PL adhesive between the shingle layers.
Hand -sealing adhesive
41-
1/4"JL
314"
Dab or asphalt
cement between 1„
shingle layers
Exterior Research and Design, LLC. Evaluation Report 3532.04.05-R13
certlficateofAuthorlratlan #9503 6EDITION (2017) FBC NON-HVH2 EVALUATION FL5444-R12
CertalnTeed Asphalt Roof Shingles; (610) 651-5847 Revision 13:09/05/2017
Page 5 of 12
TRINITYI ERD
Low and Standard Slope Steep Slope (greater than 2 :
(2:12 to 21:12); ' Use SEVEN nails and EIGHT spots of
Use FIVE nails for every full Belmont shingle, asphalt roofing cement" for every full
located as shown below. Belmont shingle. Apply asphalt roofing
cement f" (25inin) from edge of shingle_
11 a,(Icad ml See below. Asphalt roofing cement meeting
ASTM D4586 Type 11 is suggested.
I+-1' (25 mm) 1' f25 mmj—tl
v Additional Iuils it Ieuuimd.
6.6
r t2s mm)--i ---
.'
8 518'
(220mn1)
6.6.1 Hip & Rtdre for Belmont9 or eetmont° iR:
6.6.1.1 Option 1: For Belmont', refer to instructions herein for Cedar.Crestv".or Cedar Crest'"° IR hip and ridge
shingles. For Belmont' IR, refer to Instructions herein for Cedar Crest"I IR hip and ridge shingles.
6.6.1.2 P011on2. For Belmont': Shangle' Ridge
1' r'
Fasten the
left side
FIRST
aks,
1'(25MM)
Exposure Remove tape
from the right side
8+ and faslen
SECOND
RIGHT
Pigniv 17-19, IlWalbillon ojsbnu glee Ridge ibingles
Figure 17-18. Shnagle, Xlrlge. o+r hips nerd ridges
6.6.1.3 For ASTM D3161, Class F performance use BASF "Sonolastic' NPI"' adhesive or Henkel "PL'
Polyurethane Roof & Flashing Sealant", in accordance with CertainTeed requirements.
Exterior Research and Design, I.I.C. Evaluation Report 3S32.09.05-R13
Cerrilleare ofAutharizotlon #9503 6t" EDITION (2017) F13C NON•HVH2 EVALUATION FL5444-R12
CertalnTeed Asphalt Roof Shingles; (610) 651.5847 Revision 13: 09/05/2017
Page 6 of 12
63 CARfiiAGE (HOUSE°SHgNGl1 ANOGE1ANp;MANOR?
LOW AND
STANDARD SLOPE
use five nails for every NO Shangle.
5 law
(16 mm) (27mm)
F7�@rrre /7.4: Ure flee tkrila for r+rry fill! Grand �llrrnnr Shaugfe,
crurlage norm Slyrngle, or rkulemrlal S9alo.
(-1',JT'R1N1TY.jERD
STEEP SLOPE
Ilse seven nails and Ihrm spills of asplmh roofing mment for every
6dl Grind Mmor Shangle, 11.4e five halls atilt 11in+e spills of asphalt
roofing eemem for ever full Girrlage House Shingle and Centennial
Slate. Apply asphalt roofing centetil 1', (25 mm) from edge of shingle
(Rlpara 17-5). Asphalt aiotog ccmcnt nteaing MYS) 1)4580'4pe II
Is suggested.
H,gnre 17.5: wMi hiskdling 6mud JlanorNmuglcv on sleep slope,
i+so somm unlls and 16rm spills ofasplvdf mflug rmmnl.
6.7.1 Hip &'Rldse for C-arrlaee. House-Shansle09 and Grand Manor Shanjzle: Refer to Instructions herein for
Shangle® Ridge hip and ridge shingles
6.8
s
iANDMARrhCrM, LANOMARIS'"' 1R, l ANOMAfiK"=" PRO,'LANOMARI PA MIUM,°�AN10;MARK"" TL, LAiVDI�IARKY"''
SflLAR1S, LE4NDIVIAtt(r"' SOIARIS'(R, }VORTHGATE s r -� ,��.,
LOW AND STANDARD w
LANDMARK TL
SLOPE
METRIC DIMENSIONS
17, 143/4" IT
-• .(305 mm)— ,•-475
f .f.✓y^'JSirL -CR t:�t :'� x7�'ikf-T::k .�t.•faicfi cL - cZ:
w 1" (25 mm) ReM a Tape I" (25 mm) `�
Nailabta�
Am
131f2" 13" 13'f2"
I• I" (25 milt) 11" (25 mm)-� Figure l,f.•!. file fwrr halls for el-y fill sbh+gle.
NorthGate:
t+n uan 1r 14 314' 12,
t WA �.. (305 mm) —► 4� (375 mm) 1- r (335 mm)
1 Wing ur.'16
otnotfno
f -►. *+— ' (25 mm) tuWr*nallr' V (25 mm)-►
Nllorq aloes for low end ehndord ijppoa (fiurn 2:12 to 21 12)
Hatberneirn utn:er b lrnm trews thGNr a>%ra.
Exterior Research and Design, U.C. Evaluation Report 3532-09.05-1113
Certificate of Authorization N903 Ent EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R12
CertainTeed Asphalt Roof Shingles; (610) 651.5847 Revision 13: 09/0512017
Page 7 of 12
,.,[TRINITYJERD
SIEEP SLOPE
Use six nails and four spots of 11spluill roofing CCOIC111 for every filu LANDMARK Tt
lanijji;Ije(l shingle. see beloiv. Asphalt roofing cement shotifil meet
Ab7hi D4586 1),pe If. Apply I' spas of asphidi roofing ceinem mile
each cornerju(1:11 iboul 12" to 13" In front each edge. (343 mm) (330'mm) (343 mm)
ME7111C DIMENSIONS
(305 foi) (315 mm) (3m W)
(25 mm)(25 mm)
Raoting Cement
1"(25 MM) f
NA Area
ForSicepT
Ngurs,13-5- asesixnads ffndfour spots of
asphaff twfing C'N'tu", on dWP slop"
(25 mm) (25 aW
T Roofing Cement
NorthGate:
STEEP 1z, i",V 12"
SLOPE --- 3,05 610)— (375 MMY-1 —(305 lnm)-`-
NAILING
Nallin - Mill;
AAEA I suer (25 mrn)-.�—
1,11"(25 mm) Wee
Roolinn90 enyenk
Nalling areas for 869p. slopes (greatee than.21,12)
and
Will behNeen Idwer,2 nail rjn6'6 as shoWn above.
6.8.1 fflpltRidge for Landmark Landmarky.14.111, Landmark'" Pro, tandmark"m Premium, Landmark"' TL,
Landmark"' S6141s, Landmark"! Solarls I R. NorihGate:
6.8.1.1 pj2tion 1: Shadow Ridge"" or NothGate Accessary
'Te 9, W_�
P50 M) ., ,
a
Jr—,
(i25mm) 025mm)
— " (ib
0017m) (156MM)
notch for Notch for
12' 131l4'
Notches to 7516'
�14eTOPEdlied0povotts the Top Edged the PniA6S (iglimrn)
C;p1br55i8'(I4Imm) Bcposu
T\" -------
English Dimension Metric Dimension
Shadow Ridge'" Shadow RldgeTM
Exterior Research and Design, I.I.C. Evaluation Report 3532.09.05-RI3
Cenifkate ofAuthorization &9503 6"'EDITION 12017) FOC NON-HVHZ EVALUATION F1.5444-R12
CertaInTeed Asphalt Roof Shingles; (610) 651-S847 Revision 13:09/05/2017
Page 8 of 12
TRINITY # ERD
4 1 phs"(IYa t1101 )
131/8'
Caritef) q Notch
- —(333 mm)
6 610
_ III 168 mina 166 mm
131/1'
{337 trtfi) tg
`nob
r
Centering
Notch
tins taldp
G1tN Of
7 5M'
131/4'
1337 rtiin)
prltYiOtllCtx,rdu
(194n1m)
Align these
lop
edge of
7�.
MM
(184)
4
q rovious course.
r
NorthGate Ridge
NorthGate Accessory
12' _
(30.5rn��)
�+--' �.E:ttyingNotah
., ills" 13101 Use faUig notcbes to canter 9Lhiglas an UPI and
M&M, and to locate the conwi arposum
6.8.1.2 For ASTM D3161, Class F performance use BASF "Sonolastice NP1T"" adhesive or Henkel "Pie
Polyurethane Roof & Flashing Sealant", In accordance with CertainTeed requirements.
6.8.1.3 dption 2c Refer to instructions herein for Cedar Crest'", Cedar CrestT" IR hip and ridge shingles.
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-1113
Certificate ofAuthor&ation #9503 Ern EDITION (2017) FBC NON-HVHZ EVALUATION F1.5444-1112
CartalnTeed Asphalt Roof shingles; (610) 651-5847 Revision 13: 09/05/2017
Page 9 of 12
6.9 ` FRESJDEtViAl SHAKFI"`, lal;IDEfNTtALSNAKE'
LOW AND STANDARD SLOPE:
For low and standard slopes, use live nails for each full Presidential
SW* as shown below.
Figure 16 & Fa3'kwfng Pmaidmrllnl aid 8rcdlelm11al TL Shalw
sLinoks on fora muislan&vd slopes
Y. `TRINITYI ERD
SUEP SLOPE:
For steep slopes, use nine nails for each full Presidential shingle and
apply I diameter spots of asphalt roofing cement under each shingle tab.
After applying 5 calls In between Ilse calling guide lines, apply 4 nags 1"
above tab cutouts mafdng certain tabs of overlying shingle cover nails.
T
I' diameter asphalt roofing cement
Plgrrm 16 7: Faslearing Freskten1kd arrd P wOdmllal T/L Sbnlm
shllwtf s on swp slog
6.9.1 Hip & Ridge for Presidential Shake`, Presidential Shake'" IR, Presidential Shake TV". Presidential
Solar(s":
6.9.1.1 Option .1: Presidential Accessory
PRESIDENTIAL ACCESSORY
Presidential accessory shingles'can be used for covering hips and
ridges. Apply shingles up to the ridge (expose no more than 7' f>'om
the bottom edge of the "tooth." Fasten each accessory with two fas-
teners. The fasteners must be 13/4' long or longer, so they penetrate
either 3/4" into the deck or completely through the deck, Presidential
accessory comes In two different sizes; Accessory produced in
Btrmingham,•AL Is 12" x 12"; Portland, ORproduces'97/s° x 131/
accessory.
6.9.1.2 For ASTM 03161, Class F performance use BASF "SonolasticO NP1'"" adhesive or Henkel "PLO
Polyurethane Roof & Flashing Sealant', in accordance with CertainTeed requirements.
6.9.1.3 O tp ion Z: Refer to Instructions herein for Cedar Crest"", Cedar Crest"' IR hip and ridge shingles.
6.10
1.04 STANDARD AND STEEP StoPEt
Flprm lS•.1� liiif�ufirk /lnffemt Sblx�{tt ort
totewit SlandardVoprs
ror lory will skmthud slopes, use gre nails for M11 tell
MIUeeas s4inglc sts $IXAYn above.
N;tror15.1.- ruds4ing1kdArm86dnkYwr.chrp.!YW$
For steep delay, ow Grr pans aml cighi spois of upW roofing
cement for Lich full Mutems shlvoe as titnrcn AmM Alrpty V
(25mtu) dlamcler spots of roofing remcot to%rat n 45961gpe 11
surLe; 4:d) Haler Tacit lab corny- Press Alitoe Into glare; do Rot
e%rosc ecmenl.
cAurioNe too morh moffr%eeaxat Teri nurse d1logies to blister:
Exterior Research and Design, LLC, Evaluation Report 3532.09.05-R13
Cealf)cate of Authorization M03 6m EDITION (2017) F8C NON-HVHZ EVALUATION FL5444•R12
CertainTeed Asphalt Roof Shingles; (6101651.5847 Revision 13: 09/0512017
Page 10 of 12
RiN11Y I ERD
6.10.1 Hip & Ridge for' HatterasY":
6.10.1.1 Option 1: Accessory for Hatteras
s
;i
spa
1 2
Fkam 15-14, 18 tbree plecs units separate to make
541tattem Aweswrysbingt zc
6.10.1.2 Option 2: Cut Hatteras Shingles
t g" 18, (460 RIM p��h
---I—
. es
460 )
Cap Cap Cap Cap
„
dShingle .-Shingle Shingle Shingle c334a
�12�Om
Figure 15-.20., Cur Hatteras skin& to make Cofer cap. FYgtav 15 21, Insl'a/latlon of caps along Ups and ridgm
6.10.1.3 For ASTM D3161; Class F performance use BASF "Sonolasti& NP1'"A" adhesive or Henkel "PLO Polyurethane
Roof & Flashing Sealant", In accordance with CertainTeed requirements.
LOW AND STANDARD SLOPE:
STEEP SLOPE:
Use FIVE nails and SIGHT spats of asphalt roollag ecmeW for each
fail Noland Slate shingle. For hnaml-Dade, SIX nniis are tequired.
Apply V diameter spots of asphalt roolingcement under each lab
corner. Asphdtroolingcement meeting AMI D4586 Type D Is sewswa.
otoNrir.). � M4xnc0�rry.eii�.
Sixrtde(boraL
iivture au er#r
a4aAo�skan),
Flg"re rI-3� t/teFlV6nalkjoreu�ryNgGknsrtSk+resMrtgle.
Plgnro Jr-9d0ae xla nods m,aelgbl apols 41'nspcnrr
nwlingcsnuv:r vndoruacb rob crornac
'CAUTION: Excesslre use of rooting cement can cause shingles
to busim
Nips & Ridge for Highland Slate'"; Wishland Slatem IR: Refer to instructions herein for Cedar Crest', Cedar
Cresty'A IR or Shangle Ridge" hip and ridge shingles.
Exterlor Research and Design, I.I.C. Evaluation Report 3532.09.05-R13
Certificate of Autbort:oNon #9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R12
CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 13: 09/OS/2017
Page 11 of 12
'TRINITY I ERD
6.12
LOW ANDSTANDARD SLOPE
"STEEP SLOPE
Use FOUR hails foi- cveiT full shingle lwAlcd as shoWl, below.
I . FOUR nails :rod four spoi,; of aspluill roofing LrimoH for every full
sbhtglc ns shomi below: %sph:dl roofing cenienl ineding,►.4l'b1 D4586
1)pe II is suggesled. Apph' 1'(25 )in,) spuls of asph:dl raolhig
S€alaM
ccnu�tl :Lc Shon•n,
L+ MIre V
CAUTION: INCeAve tuc Of I Ing cenmil Call Cause shingles G2 blLcl(�r.
ITS ptr) (2S mmj
(156 num)
Ti-
3'331r,nJ
uY�mtd l;e
..i_ —
Roalinp Cpneet-
it tp' i13
6.121 Hip & Rifta for Patriot'"':. Refer to instructions herein
for Cedar Crest'"', Cedar CrestTm IR, Shadow Ridge'",
NorthGate or Shangle Ridge'" hip and ridge shingles.
LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1 / R905.2.6.1.
BUILDING PERMIT REQUIREMENTS:
As required by the Building•Official or Authority Having Jurisdiction in order to properly evaluate -the installation of this
product.
MANUFACTURING PLANTS:
Contact the. named QA entity -for, information on .which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625; (414) 248-6409; karen.buchmann@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC.
Certificate ofAathorlratfon #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Asphalt Roof Shingles; (610) 651-5847
Evaluation Report 3532.09.0S-R13
FL5444-R12
Revision 13: 09/OS/2017
Page 12 of 12
�/4/2fl�8 Florida Building Code Online
BCIS Home Log In I User Registration Hot Topics I Submit Surcharge Stats & Facts Publications FBC Staff I BCIS Site Map i Links �i Search
Florida
L Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
• +ei:_d, FL # FL21350-R1
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative .,
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
The QA entity has been called into question.10/16/17
Atlas Roofing Corporation
2000 RiverEdge Parkway
Suite 800
Atlanta, GA 30328
(770)946-4571
mcollins@atlasroofing.com
Meldrin Collins
mcollins@atlasroofing.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
i Evaluation Report - Hardcopy Received
Zachary R. Priest
PE-74021
Intertek Testing Services NA, Inc. - QA Entity
12/31/2099
Locke Bowden
v, Validation Checklist - Hardcopy Received
FL21350 R1 COI ATL16001.1 2017 FBC Eval Report Summit
Underlavments final.odf
1507.1.1
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgve007nSKOaGG1n00QjbPsHZx6O4z4FctlJN8mPQQEF2wp/o3d%3d 1/2
.".1 /4/2018
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Florida Building Code Online
Method 2 Option B
09/30/2017
10/04/2017
10/08/2017
12/12/2017
FL #
Model, Number or Name
Description
21350.1
Summit Underlayments
Mechanically attached, synthetic underlayments used as an
alternative to ASTM D 226 Type I and II underlayment.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21350 R1 II ATL16001.1 2017 FBC Eval Reoort Summit
Underlavments final.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL21350 R1 AE ATL16001.1 2017 FBC Eval Reoort Summit
Underlavments final.odf
Created by Independent Third Party: Yes
Contact Us ;: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
._ The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions., please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under.Chapter 455, F.S.,
please click here .
.. Product Approval Accepts:
-N9 - ..
Credit Card
Safe
N.
ttps://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgve007nSKOaGGIn00QjbPsHZx6O4z4FctlJN8mPQQEF2w%3d%3d 2/2
.7
2 IL
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer: ATLAS ROOFING CORPORATION
2000 Riveredge Parkway, Suite 800
Atlanta, GA 30328
(770) 612-6267
www.atiasroofin.g.com
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE, 6TH EDITION (2017)
Manufacturing Locations: Hebei, China
Quality Assurance: Intertek Testing Services NA Inc. (QUA1673)
SCOPE
Issued September 30, 2017
Category:
Subcategory:
Code Sections:
Properties:
REFERENCES
Roofing
Underlayments
1507.1.1
Physical properties
Entity
Report No. Standard Year
Intertek Testing Services NA,
Inc. (EVL11327) CCRR-1038 AC 188 2012
Intertek Testing Services NA,
Inc. (EVL11327) CCRR-1038 ASTM D 226 2009
Intertek Testing Services NA Ltd. (TST1509) 141128020SHJ-BP-1 AC 188 '2012
PRODUCT DESCRIPTION
Summit 30
A mechanically attached, synthetic underlayment used an alternative to ASTM D 226,
-Type, I and Type II roofing underlayments. The roll is available in 48-inch, ,wide x 150-ft
long format and weighs approximately 20 lbs.
Summit 60
A mechanically attached, synthetic underlayment used an alternative to ASTM D 226,
Type I and Type II roofing underlayments. The roll is available in 48-inch wide x 150-ft
long format and weighs approximately 23 lbs.
Summit 180
A mechanically attached, synthetic underlayment used an alternative to ASTM D 226,
Type I and Type II roofing underlayments. The roll is available in 48-inch wide x 150-ft
long format and weighs approximately 30 lbs.
Summit 190
A mechanically attached, synthetic underlayment used an alternative to ASTM D 226,
Type I and Type II roofing underlayments. The roll is available in 48-inch wide x 150-ft
long format and weighs approximately 38 lbs.
ATL16001.1 FL21350-R1 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
N
CREEK
TECHNICAL SERVICES, LLC
APPLICATION INSTRUCTIONS
ATLAS ROOFING CORPORATION
Summit Underlayments
Deck Type: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing
construction.. Sheathing shall be installed in accordance with FBC requirements. Roof
decks shall have no more than 1/8" gap at abutting joints.
Attachment method: Underlayment shall be attached in accordance with the FBC and manufacturer's
installation instructions. The underlayment is installed starting at the eave, with the
length of the roll parallel to the eave with the printed side facing up. All side laps shall be
installed to shed water from the deck. End laps shall be staggered between courses in
accordance with the manufacturer's application instructions. Minimum application
temperature shall be 50°F.
Allowable roof coverings: Mechanically fastened roof coverings as prescribed in FBC Table 1507.1.1 shall be
permitted.
LIMITATIONS
1) This evaluation report is not for use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance is not within the scope of this evaluation.
4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail. -
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Roof slope limitations shall be in accordance with FBC requirements.
7) Contact the manufacturer when installing at temperatures below the minimum application temperature.
8) The underlayment may used as described in other current FBC product approval documents.
9) Roof coveringsshall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.
10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
ATL16001.1 FL21350-R1 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
X
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
ATLAS ROOFING CORPORATION
Summit Underlayments
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
,�P.' •.R�'- 2017.09.30
\G•E•NSF•
No 74021
• % 12:51:10
04'00'
� '.•. S TAT E OF : �4/`
®omT •.�� O `vo` Zachary R. Priest, P.E.
s R (j �` Florida Registration No. 74021
,0NA `� ,,moo Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.,,
END OF REPORT
ATL16001.1 FL21350-RI Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
SCPA Parcel View: 02-20-30-523-0000-1140
Page 1 of 2
opav�a annFunp.cr�FA' Property Record Card
PR�P� Parcel: 02-20-30-523-0000-1140
ta:na.ecflurnv ricxno� Property Address: 128 GLEASON CV SANFORD, FL 32773-4451
Value Summary
2018 Working
Values
2017 Certified
Values
Valuation Method
Cost/Market
Cost/Market
Number of Buildings
1
1
Depreciated Bldg Value
$161,686
$143,305
Depreciated EXFT Value
Land Value (Market) y
$1,150_
$28,000
$1,200
$25,000
Land Value,Ag
Just/Market Valuee $.836190
$169,505
http://parceldetail.scpafl.org/ParcelDetailInfo.aspx?PID=02203052300001140 2/7/2018
City of Sanford Building Division
Residential Re -Roof Inspection Policy & Procedures
PERMITTING REQUIREMENTS — NO PLAN REVIEw REQUIRED
This document (signed) along with an accurate and�completed Residential Re -Roof Scope of Work are required
to be submitted as part of your permit application.
The Scope of Work must include all applicable Florida Product Approval numbers for all roof components that
will be installed on the project.
A permit will not be issued without these documents. Copies will,be made to post on the job site.
"Projects located in the Sanford Historic District will require plan review and approval by the Sanford
Historic Preservation Board
INSPECTION POLICY & PROCEDURES
A Final Roof Inspection is the only inspection required 1for: Residential (Single Family, Townhouse, Mobile
Home, Apartment and/or Condominium) Re -Roof Permits.
The Following is required to be provide on the job site:
a Permit Card, posted in a conspicuous and weatherproof location
O Completed Residential Re -Roof Scope of Work
a Completed and Notarized Inspection Affidavit
a All Florida Product Approval and Corresponding Installation Instructions
a (Product Approval shall match what is on the scope of work)
a Digital Photographs (must include the permit number or address in each picture)
o Each plane of the roof, showing the underlayment installed
o Roof Deck Nailing Pattern & Spacing (including a measuring device or ruler)
o Roof Deck Nails used (including a measuring device or ruler showing size of nails)
o Underlayment Pattern & Spacing (including a measuring device or ruler)
o Drip Edge & Valley Attachment (including a measuring device or ruler)
o Shingles installed, nail pattern and location of nails
Skylights (if applicable)
o Digital photographs showing all installation components, per FL Product Approval
o Digital photographs showing all required,flashing, per FL Product Approval
Failure to follow these specific guidelines will result in an affidavit provided by a Florida Design
Professional (architect or engineer), certify' BC code co pliance by personal inspection.
CONTRACTOR (OR OWNER/BUILDER) SIGNATURE: / DATE:
PERMIT # / 0 - _�
City of Sanford Building Division
Residential Re -Roof Scope of Work
JOB ADDRESS:
STRUCTURE TYPE: (erSINGLE FAMILY RESIDENCE/TOWNHOUSE O MOBILE HOME O APARTMENT/CONDOMINIUM
RE -ROOF TYPE: PLACEMENT (TEAR OFF EXISTING ROOF AND REPLACE WITH NEW COMPONENTS)
O RE-COVER (NEW ROOF INSTALLED OVER EXISTING ROOF)
DECK TYPE (PLEASE SPECIFY):
* *PLEASE NOTE: ONLY 100 SQUARE FEET OF E EXISTING DECK IS PERMITTED TO BE REPLACED
ROOF VENTILATION: D OFF -RIDGE RIDGE OSOFFIT OPOWERED VENT OTURBINES
SKYLIGHTS: O YES (!5/NO IF YES, PLEASE PROVIDE FLORIDA PRODUCT APPROVAL #:
MAIN ROOF AREA
ROOF SLOPE: O LESS THAN 2:12 O 2:12 - 4:12 4:12 OR GREATER
TYPE 9F ROOF
MANUFACTURE
FLORIDA PRODUCT APPROVAL
SHINGLE
�`� �0�
FL#�
"- L
O METAL
FL#
O MODIFIED BITUMEN
FL#
O TORCH DOWN
FL#
OINSULATED
FL#
O TILE
0 OTHER: V ��
FL#
_
FL#
ROOF EXTENSIONS (PORCHES PATIOS ETC.) **IFAPPLICABLE**
ROOF SLOPE: O LESS THAN 2:12 O 2:12 - 4:12 O 4:12 OR GREATER
TYPE OF ROOF
MANUFACTURER
FLORIDA PRODUCT APPROVAL
O SHINGLE
FL#
O METAL
FL#
O MODIFIED BITUMEN
FL#
O TORCH DOWN
FL#
OINSULATED
O TILE
0 OTHER:
FL#
FL#
FL#