Loading...
HomeMy WebLinkAbout331 Red Rose Ln (3)Application No: r FEB 13 201� �Y CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Documented Construction Value: $ems Job Address:. " E05.Q ��1 0 ��� 11� Historic District: Yes ❑ N Parcel ID: a- I 1 - 3b 7T' O'3 `f� 3-20Z 1 1 Zoning: Description of Work: Plan Review Contact Person: Vf/ hnex- i ne Title:y P Phone: i4D1-10SIZ- oto O`j Fax: — E-mail: k bree-K C (5�p so "41 . Property Owner Information Name % L 1 Phone: Street:1 ja� -� 2 Resident of property? �,Ij City, State Zip: &t c��Yc� �a �"7 Contractor Information Name _ rt 4, 0l taco Phone: 40- - (08g 0(.00S Street: To City, State Zip: n°-&�A� L5a-7-7 Fax: State License No.: ckCO2Q:73-1 Architect/Engineer Information Name:�i�A Street: (44� P Ta M(' QYh t _— - llj City, St, Zip: C+10L� L9-M--2.f(1 3� 8 O Bonding Company: Address: Building Permit Square Footage: _3DO Phone:gq I mil- n-E a Fax: E-mail: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: No. of Stories: No. of Dwelling Units: Flood Zone: Electrical ❑ New Service - No. of AMPS: Mechanical 0 (Duct layout required for new systems) Plumbing ❑ New Construction - No. of Fixtures: Fire Sprinkler/Alarm ❑ No. of heads: J Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. 7 tS a e of Owner/Agent . K�Y\(�« 1LlT�CX1Q� Print' ownep/Agent's Name of Florida 1 Date Owner/Agent is Personally Kno. c A�! a/qp0/Fi0,�� Produced ID Type of IDfflps� s�/9 APPROVALS: ZONING: IN I(e) UTIL ENGINEERING: COMMENTS: n a�1b ins u a+eA WI FIRE: 2-12_G •`;o,`"�e % PHILLIP A. HAGUE Notary Public - State of Florida A., My Comm. Expires Apr 1. 2018 Commission #JF 106332 r g n is ersonal y own to Me or ID Type of ID WASTE WATER: BUILDING: -OF 2 - b - r g 'Oh cre-k s lab wt1i cc,(e se acks s o t/1-1 fln Ptah . Rev 11.08 SCPA Parcel View: 21-19-30-5TT-0000-0340 Property Record Card Parcel: 21-19-30-5TT-0000-0340 Property Address: 331 RED ROSE LN SANFORD, FL 32771 Parcel Information Parcel 21-19-30-5TT-0000-0340 Owner LITZNER, KATHLEEN M Property Address 331 RED ROSE LN SANFORD, FL 32771 Mailing 331 RED ROSE LN SANFORD, FL 32771 Subdivision Name THORNBROOKE PHASE 1 Tax District S1-SANFORD DOR Use Code 01-SINGLE FAMILY Exemptions OD-HOMESTEAD(2017) g + � � 34.43 •cP IQ CP w Z Cs W '. 0 a 20i 118 Seminole County GIS Legal Description LOT 34 THORNBROOKE PHASE 1 PB79PGS3TO7 Taxes Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund $254,883 $50,000 $204,883 Schools $254,883 $25,000 i $229,883 City Sanford $254,883 $50,000 ' ___-_-- $204,883 SJWM(Saint Johns Water Management) $254,883 $50,000 $204,883 County Bonds $254,883 $50,000 ( $204,883 Sales Description Date Book Page Amount i Qualified Vadimp SPECIAL WARRANTY DEED 6/1/2016 08710 0923 $288,500 Yes Improved Find Comparable Solos Land Method Frontage I Depth V (Units Units Price Land Value ( LOT t_ 1 $45,500.00 $47,775 Building Information --- ------- -. Bed/Bath count incorrect? Click Here. # Description Year Built Fixtures Bed Bath Base Area Total SF Living F Ex Actual/Effective t Wall Adj Value Repl Value Appendages 1 'SINGLE 2016 11 4 2 5 1,199 ' 3,135 ; 2,468 i CB/STUCCO { $214,153 $215,229 FAMILY FINISH Description Area GARAGE 462.00 a FINISHED i "OPEN r i i PORCH 205.00 - I n�ucucn i THIS INSTJtUMENT PREPAIIIE D BY: Name. cil:_i!';'li'i...s.{tAM '' :,t:ii:tiL1LR_ (t)tJ1'Ii'` Address "i._;::C:K- tJR Cl:E;;C:U}: i cCli_lf'tT & c_(�i`ff'TrtCiL.L_E:rt C:LERtK'' S 2018017014• NOTICE C 1 { ft4di:�„iC.E 1?i'ij:{.f'•'iifl Permit Number: Parcel ID Number: g21-Iq - bo- L-5, TT-ocpo— 03q The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) 2. GENERAL DESCRIPTION OF IMPROVEMENT: In'9I A(r �k d Z>Q 3. OWNER INFORMATION Oft LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: IsaAln" e (l L-, T 2 :> n I Y-W-CX L�>rF- LA-) QY t\r-y rGi Udl- 1 t Interest in property: UtOro r Fee Simple Title Holder (if other than owner listed above) Name: 4. CONTRACTOR: Address: 5. SURETY (If applicable, a copy of the payment bond is attached): Name: sa 11 .- i 1•� Address: Amount of Bond: 6. LENDER: Name: Phone Number: Address: _ 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as prc 713.13(1)(a)7., Florida Statutes. ANO Name. Phone Number. 8. In addition, Owner designates of BY to receive a copy of the Lienoes Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. I�LQ'e'n L(tZ4U,4- LAZ)ma,t~ (Signat�ofOer or Le , or Owner's or Lessee's (Print Name and Provide Signatory'sTitle/Office) Authorized Officer/Director/Partner/Manager) State of �I (JQ. County of The foregoing instrument was acknowledged before me this day of , 20 by V� p 1 l�c-E Zc Wh onally known t me ❑ OR Name of person making statement who has produced identification 0 type of identification produced: •""r'p "�• r;• 4 KATHERINE BREEHL Notary Public - State of Flotlda ' • °,i My Comm. Expites Apr 1, 2016 Commission 0 FF 1063% d ��rt \`v"W Signature LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Labe Mary, Longwood, Oviedo, Sanford, Seminole County, Winter Springs Date: I hereby name and appoint: K:H0,e (—r n. 1 -,-Pe—hJ an agent of: Amie - ca-4n cLyy-\,, o,�� 1�1 (Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): ❑ All permits and applications submitted by this contractor. The specific permit and application for work located at: 0 Address) Expiration Date For This Limited Power Of Attorney: License Holder Name: L j • B ree" State License Number: Signature of License He STATE OF FLORIDA COUNTY The foregoing instrument was acknowledged before me this of , 20 by (.� ►� Qs personally known to me/ or who has produced as identification and who did/did (Notary Seal) Signature V " o . Print or Type N Notary Public — ' °'�tYP'M�on, '° b���4 °,� ' Fx Spar GAF Commission Number �'Ssio °j'Ps e°/F FF � 0j My Commission Expires: REQUIRED INSPECTION ECTION SEQUENCE BP# 1Q — 3�2 slamDMKG pls Mnn Max-Ynsectlon.I<Descri d6n. Footer / Setback Stemwall Foundation / Form Board. Survey Slab [ Mono Slab Pre our Lintel / Tie Beam / Fili / Down Cell Sheathing— Walls - Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen.Room Final. Pool Screen Enclosure Mobile Home Building Final Pre -Demo Final Demo Final Single Family Residence Final. Building. Other I Address: 3 31 r2 b Po SIB )�� I�� ¢� _._.. Min Max. Ens2ec® pDescri2flonn Electric. Underground Footer /' Slab Steel Bond Electric Rough T-U.G. Pre -Power Final Electric Final s.Nv+�y�i'r"-wY? u'�c �..�ary w.atCi... .i7x t,. `+Sr�i3:' .�.,`dg. Max. ][imectllon IlDescrIl] tion MllIlIl Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final _......._._..... ��illl I\ _........... III �0 ��111111 ��1 �'�iI IIUIi�U 111 Mechanical �uh �— Mechanical. Final ail.. I..1\ Iw fur lluel IIIc 1�uilnnl derground REIEWS EIID: June 2014 Owners: Kathy Litzner Address: 331 Red Rose Lane Cit\, state: Sanford, FL Subdivision: Email addresses: ftgreernrrn Date: Aug 4, 2017 Work Phone r: Z'P: 32771 Home Phone =: Cell Phone 1: 407-923-5691 Email addresses: Color: Bronze Excavate an area on the rear of the house 12'x 25'6"x 12 . Cut and cap irrigation, Pour a concrete slab, with an S" thickened footer edge with steel rebar. Broom finish install a Screen Room Enclosure,12'x 256" x 12' includes a 3" insulated roof And a 2' overhang, trim and gutters. Solid post Powerbeams with Wide picture Window views. Start height of 11' tall,16" aluminum kickp/ate.1 door, Anchors away hidden fastener base plate, fiberglass screen. Tax, engineering, building permit included Total $9957.00 Credit 1 door-$100.00 2— prewired fan beams + $500.00 Total $10,357.00 ** electrical hook up to the house is not included. TOTAL: $ 10 357.00 Performance Draw Schedule as Follows: Notes: "NO BLOW DOWN WAKKAIV t f 20 years Deposit $ 3000.00 Delivery of enclosure Draw $ 3500.00 After Concrete Pour Draw $ 1800.00 NA Draw $ NA Draw $ Completion Draw $ 2057.00 Len Bre.eh Y . r—� /�l ? _........ Owner Date cree osures Sal ep t / 1 SEE REVERSE FOR DITIONAL TERMS Oivner Date BY SIGNM THIS AGREEMENT YOU AGREE TO THESE TERMS. GENERAL NOTES 1. DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2017 FLORIDA BUILDING CODE, 6TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23 WOOD. 2. ASCE 7-10. & SE17 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. AC1318 CONCRETE REFRENCE MANUAL. 5. PCI PRECAST & PRESTRESSED CONCRETE. 6. AA ASM 35 & AA ADM 1 WIND LOADS: 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 130 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. SCREENED ROOF ENCLOSURE FBC 2017 CH. 20 TABLE 2002.4 CONCRETE & FOUNDATION DESIGN: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: A. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 - ASTM C 150 II. AGGREGATES - LARGE AGGREGATE 3/4" MAX. - ASTM C 33 III. AIR ENTRAINING +/- 1% - ASTM C 260 IV. WATER REDUCING AGENT - ASTM C 494 V. CLEAN POTABLE WATER VI. OTHER ADMIXTURES NOT PERMITTED B. METAL ACCESSORIES SHALL CONFORM TO: I. REINFORCING BARS - ASTM A615, GRADE 60 II. WELDED WIRE FABRIC - ASTM A185 C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. D. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. E. MOIST CURE OR POLYETHYLENE CURING PERMITTED. F. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. G. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. FOOTING SIZE: EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB (3000 PSI) IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. 3. WHEN APPLICABLE FOR ATTACHING NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS. 4. WHEN INSTALLING 4" CONCRETE SLAB -ADD ADJACENT TO EXISTING-DOWELL INTO EXISTING CONCRETE 48" O/C W/8" #5 REBARS- DRILL 3/4" HOLE 4" EMBEDMENT- EPDXY W/ NON -SHRINKING "SIMPSON EPDXY TIE" (OR EQUAL). 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHER WISE NOTED. ALUMINUM SPECIFICATIONS: 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE SPECIFIED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. FASTNER SPECIFICATIONS: 1. FASTNERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG.) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, AND FASTENERS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4"X3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4"X2-3/4" TAPCONS OR EQUAL AT 24" C.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14X2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10X1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE VX2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5-0" IN HEIGHT. MISCELLANEOUS: RECORD COPY �1 S( L S FEB 13 2018 ��\\\111111111//// i� � zip Cj (D o CD ': o O =z o - w a 00 0 ;v Co Q z N o • > z "' D r4 w o u; 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND INSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4101.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE SMB UNLESS OTHERWISE INDICATED RESPONSIBILITIES: 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. LEGEND: (ALL MAY NOT APPL SCR = SCREEN KP = KICK PLATE PW = PICTURE WINDOW X = HORIZ. SLIDING WINDOW O = HORIZ. STATIONARY WINDOW DH = DOUBLE HUNG WINDOW SH= SINGLE HUNG WINDOW SIP = SOLID INSULATED PANEDLEVI!EWED FORCODECOMPLIANCE CT = CABLE TIE SG = SUPER GUTTER p N6 EXAMINER CS = CLEAR SPAN .1q, I$ KB = KNEE BRACE DATE ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2"x2"x0.044" 2 x 3: 2"x3"x0.044" 2 x 4: 2"x4"4.044" 2 x 5: 2"x5'4.050" SANFORD-E UILDIN IVI ION OPEN BACK SECTIONS A PERMIT ISSUED S IALL BE CONSTRUED TO BE A 1 x 2: 1 "x2"x0.044" LICENSE TO PROCEE WITH THE WORK AND NOT Al 1 x 3: 1 "x3"4.044" AUTHORITY TO Vi0 ATE, CANCEL, ALTER OR SET ASIDE ANY OF THE P OVISIONS OF THE TECHNICAL IONS CODES, NOR SHALL I UANCE OF A PERMIT PREVEP SNAP SECT 2 x 2 SNAP: IONS THE BUILDING 0 FICIAL FROM THEREAFTER 0.050„ 2 x 3 SNAP: 2"x3"x0.050" REQUIRING A CORK CTION OF ERRORS IN PLANS, CONSTRUCTION 0 VIOLATIONS OF THIS CODE 2 x 4 SNAP: 2"x4"x0.045" SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044"x0.100" 2 x 5 SMB: 2"x5"x0.050"x0.100" Ov��D�NG 2 x 6 SMB: 2"x6"x0.050"x0.120" 2 x 7 SMB: 2"x7x0.057"x0.120" SANFORD 2 x 8 SMB: 2"x8"x0.072"x0.124" 2 x 9 SMB: 2"x9"x0.082"x0.124" �Ff'A.R,�= 2 x 10 SMB: 2"x10"4.092"4.398" NOTE: AS INDICATED ABOVE ALL MEMBER PROFILES ARE INDICATED 1 8- 8 5 2 IN INCHES. 1X2 f--—10'-7" HOUSE o NEW 4" CONCRETE SLAB N 3000 PSI W/ FIBERMESH 8" x 8" FOOTER 25'-6" CONC. PLAN SCALE: N.T.S. HOUSE WALL I I I I I I I I =I I OI I 01 3" x .024"x1 LB INSULATED ROOF 3105-H14'/4"-1' SLOPE (MIN.) FL7561-R4 I li I I I I I I I 1'-0" O/H I SEE DETAIL "B" PAGE 4� m a X N 25'-6" 2X8SMB C.B. V IT V N N 2X4X.044 N 16" .024 KP 6-4 -" -1 6-4 1"---6'-4 1"- 6-4 1" 0�1.2 Grade 3000 PSI 8 FIBERMESH 8" X 8" FOOTI G W(1) #5 REBAR CONT. 1X2 a Y CO X (.0 N `- 2X2 DJ 2X2 DJ N N X x N � 1X2 10'-7" -i SEE DETAIL m "B" PAGE 4 Lo x N Q�: N LL Q-' LLI =Z:co o O J a 00 w N .U_ Q - Z � �O O C� ''� �6- ' •.. L i P.R•'' U� (4) #10x3/4" SMS FASTENING SECONDARY ANGLE TO COLUMN (TYP EACH SIDE) (B) 3/8" 0 CONCRETE SCREW ANCHOR INTO SECONDARY ANGLE (TYP EACH SIDE) (SEE TABLE) ANCHOR SPA (MIN) (TYP) (SEE TABLE) COLUMN SIZE 3/8" 0 CONCRETE SCREW ANCHOR B MIN SPA 2X3 0 0 2X4 1 3 2X5 1 3 2X6 1 4 2X7 1 5 2X8 2 3 2X9 2 4 2X10 2 4.5 NOTES: SECONDARY ANGLE MIN 0.125" THICK (NOT REQUIRED FOR 2x3 MEMBER) ,-PRIMARY 2"x2" x0.125" ANGLE 2) #10x3/4" SMS FASTENING COLUMN TO PRIMARY ANGLE O (TYP EACH SIDE) O O "x2" BASE MEMBER (TYP EACH SIDE) 1) 3/8" 0 CONCRETE SCREW ANCHOR INTO PRIMARY ANGLE AND @ 1/4" 0 CONCRETE �T' MIN. SCREW ANCHOR @ 24" O.G. BETWEEN COLUMNS (TYP EACH SIDE) 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2 3/4" AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTH AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED ON S-1, D. FASTENERS, OTHER BRAND & TYPE SHALL BE APPROVED BY ENGINEER. 4. 2X3 W/ 1X2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. 5. IF FOR AN IN -FILL, TOP OF COLUMN CONNECTIONS SIMILAR IF CONCRETE LINTEL IF WOOD LINTEL SUBSTITUTE 1/4" 0X3" LAG SCREW FOR 3/8" 0 LDT FOR BOTH PRIMARY & SECONDARY ANGLES. 6. 2X2X.045 DOOR JAMB MEMBER SHALL CONNECT SIMILAR TO 2X3 MEMBER. 2"x3" OR LARGER UPRIGHT TO CONCRETE W/WO PAVER DETAILS SCALE:NTS HOST ROOF PER PLAN ALTERNATES FOR COL. TO 2"X2"AT HEADER: 1- DETAIL "C" SHT 3 2-(4)#10X3"SMS THROUGH MEMBER ABOVE INTO COL SCREW BOSS 3- NOTCH COL. TO RECEIVE BEAM FASTEN W/ (2) W THRU-BOLT I CHAIR RAIL PER PLAN II 1 /4"X2-3/4" TAPCONS -OR EQUAL AT 24" O.C. AND 6" FROM ENDS WHERE KICK PLATE IS INDICATED FASTEN W/ #10 X 9/16" SMS 8" O/C AT PERIMETER COL. PER PLAN 1 "X2" FASTEN TO' ADJOINING WALL W/#12 X 1-1/2" SMS @ 18" O.C. .024 FLASHING SEALED TO WALL (TYP.) 0 O O O O #12x3/4" SMS @ 12" O.C. TOP & BOTTOM r 050-3" RECEIVING CHANNEL CONCRETE OR FILLED FASTEN TO MASONRY WALL MASONRY W/ 1/4" X 3" TAPCONS 18" O/C (INTERNAL) ROOF PANEL ATTACHMENT - MASONRY SCALE:NTS 2"X2" PER PLAN ATTACH TO ROOF PANELS W/# 12 X 2-1/2" SMS 12" O/C 6" FROM ENDS -CARRIER BEAM (2) 1/4" THRU-BOLT SEE ALSO COUEDGE BEAM ALTERNATES ADJOINING BEARING WALL 1" X 2" FASTEN TO ADJOINING WALL W/#12 X 1-1/2" SMS @ 18" O.C. WHERE SMB USED FOR COL. ATTACH PER DETAIL "B" ................................................. ............... ..,....................... EXISTING CONCRETE TYPICAL SIDE WALL 1/4" TAPCON (RED HEAD MFG. OR EQUAL) 6" FROM ENDS 24" O.C. COLUMN 1-1/2" PENETRATION INTO UNDERLYING FOOTING SCREEN ROOM END WALL SCALE:NTS WALL HOST EXISTING RAFTER OR TRUSSER O C O C #12x3/4" SMS @ 12" O.C. TOP P & BOTTOM .040 X 3" U-HEADER 2" NOMINAL STRUCTURAL FOR COMPOSITE PANELS: FASCIA MIN. (2) #12 X 2"SMS THROUGH RECEIVING FOR ALUMINUM PANS: CHANNEL @ 12" O.C. #12 X 2" SMS THROUGH "BOXED END": INTO WD FASCIA ALTERNATELY: (3) PER PAN (1) 1/4"x3" LAG BOLT THROUGH RECEIVING CHANNEL @ 12" O.C. ROOF PANEL ATTACHMENT - WOOD FRAME SCALE:NTS FOR ALUMINUM PANS OR GALVALUME STEEL PANS USE #12 X 9/16" W/ 5/8" NEO-WASHER (3) PER PAN FOR COMPOSITE PANELS #12 X 1" LG. THAN PANEL THICKNESS SMS W/ 1-1/2" NEO-WASHER 12" O/C ROOF PER PLAN I f II /COVER END OF PANEL BEAM PER PLAN (2) 1/4" THRU-BOLT - SEE ALSO COL/EDGE BEAM ALTERNATES POST ROOF TO CARRIER BEAM CONNECTION SCALE: NTS nciOPEN BACK TO HOST DETAIL SCALE:NTS ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL w/(4) #10x.75" INTO GIRT OR PURLIN & (2) #14x.75" INTO BEAM OR UPRIGHT 0,062 ANGLE CLIPS MAYBE USED #10x2" SMS INTO REW BOSSES UPRIGHT, BEAM -SNAP, SELF MATING, OR HOLLOW DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE:NTS C) 0) f P1 co� Z 7 Q Q p U U w J 0 00 — LLB Q J 0) LL Lr) .s I1 w L C vZ M Or-�' Lu Q NJ L. N 4> Q 0 Q F.-U = > 0 Lo J LL N O 0 W N 00 r O M w U U M 0 .94- O 00 FOR WOOD APPLICATION: #10 x 3" WOOD SCREWS @ 12" O.C. O CONCRETE: 1/4" DIA. x 3" CONCRETE ANCHOR 0 @ 24" O.C. Z Z W W 06 C) U) Z J J W Q W O LL Z� UW w WWO W a N,Z Q(n w J(h(n O O d DESIGN DATE: 02/12/2018 REVISION 1: DATE PAGE: REVISION 2: DATE SCALE: NTS ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2x2:2"x2"x0.046" 2 x 3: 2" x 3" x 0.050" 2 x 4: 2" x 4" x 0.050" 2x5:2"x5"x0.050" OPEN BACK SECTIONS 1x2:1"x2"x0.040" 1 x3:1"x3"x0.045" SNAP SECTIONS 2 x 2 Snap: 2" x 2" x 0.045" 2 x 3 Snap: 2" x 3" x 0.050" 2 x 4 Snap: 2" x 4" x 0.045" SELF MATING (SMB) 2 x 4 SMB: 2" x 4" x 0.044" x 0. 100" 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" 2 x 6 SMB: 2" x 6" x 0.050" x 0. 120" 2 x 7 SMB: 2" x 7" x 0.057" x 0. 120" 2 x 8 SMB: 2" x 8" x 0.072" x 0. 124" 2 x 9 SMB: 2" x 9" x 0.072" x 0. 124" 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" MINIMUM FASTENER EDGE DISTANCE: 1/2" MINIMUM FASTENER SPACING: 3/4" CONCRETE SCREW ANCHOR: SIMPSON TITEN HD OR EQUIVALENT SHEET METAL SCREWS (SMS): ITW/BUILDEX OR EQUIVALENT 1 /6" x 2" x 2" EXTRU ANGLE 6052 H-32 ALLO j F_00 SLAB/FOOTING �A SEE PLAN F SIDE VIEW (1) 3/6" DIA. CANCRETE SCREW ANC+IQRS (2 1/4" CAN( EMBE 1" x 2" BASE PLATE ANCHORED TO CONC W/ CONCRETE SCREW A pR; ;. ; (MIN. 1 1/4" EMBED) 6" MAX EACH SIDE OF POS AND 24" O.C. MAX FRONT VIEW 4000 P81 GROUT FILLED SELF -MATING SECTION W/(2) #5 REBAR DOWELED INTO SLAB W/ EPDXY ADHESIVE 6" MIN. 1"x2" INTERNALLY SCREWED -'J INSPECTION HERE 4" TO THRU UPRIGHT W/ (2) #10 x 1-1/2" ', ; i 6" ABOVE SLABE FASTEN 1 "x2" TO CONCRETE W/ i 1/4" x 2-3/4" CONCRETE ANCHOR i'.',' ,•. 6" FROM UPRIGHT & @ 24" O.C. j," ".;"j [[• 4 11 .. I. I SEE PLANE FOR I I FOUNDATIO 41 REQUIREMENTS f I. 5d MIN EDGE DISTANCE FROM EXTERIOR OF COLUMN TO I... OUTSIDE EDGE OF SLAB SIDE VIEW SELF -MATING UPRIGHT FILLED W/ COCRETE TO DECK DETAILS SCALE:NTS (4) # 14 x 3/4" SMS 1 1/2" x 12" x 0.125" INTO DJ 6063-T6 ALUM STRAP W/ (5) #14 x 3/4" 2x2 ANGLE CONNECTION AT IN BOTH 2" x SMB / BACKSIDE OF BEAM SEE CARRIER BEAM & 2" x / D-1/A-2 SMB UPRIGHT EA. SIDE DJ-1 DOOR JAMB TO CONCRETE DETAIL SCALE:NTS 0 0 0 2"x3"DJ 0 0 0 1x2 O.B. ATTACH TO UPRIGHT WITH (2) #10 x 2 1/2" SMS THRU ° UPRIGHT INTO SCREW BOSES PLUS #10 x 1 1/2" SMS 6" FROM EACH SIDE OF UPRIGHT AND TYPICAL AT 24" O.C. MAX S-1 CARRIER BEAM CONNECTION SCALE: NTS 2" x 2" x 1/6" x 6" ANSI F BOTH SIDE W/(4) #14 x 5/8" SMS CARR' TOP OF GROUND D-1 FRONT WALL POST TO CARRY BEAM CONNECTION DETAIL SCALE:NTS 1"x2"O.B-' 2"x2"x1/8"x12"LONG ALUM PLAT W/(8) # 14 x 3/4" EACH SIDE OF SPL 2" x POWER REINFORCEMENTS TO 12" BELOW TOP OF POST ;T EAM FRONT WALL CARRIEI 00 00 00 _ 00 0 0 (8) #14 x 3/4 0 OVERLAP UPRIG °O SIDE 00 2" x POW[ FRONT WALL ELEVATION SIDE WALL ELEVATION , 04 o ,,// m •• LLI Q IL C4 0 00 (7 U CO -�K Q %; z— 0 N ZU) _ �i •°•., ,, d•,� ........RAF W LU P 2" x SMB FRONT L " x 2" x 1/8" x 12" ALUM ANGLE CARRY BEAM W/(8) # 14 x 3/4 SMS EACH LEG 2" x POWER BEAM 2" x SMB 2" x SMB SIDE WALL UPRIGHT ,--CARRIER BEAM NOTCH TO OVERLAP UPRIGHT \ (8) #14 x 3/4" SMS @ 2" x 2" x 1/8" x 12" ALUM PL E VERLAP BETWEEN W/(8) # 14 x 3/4 S UPRIGHT AND EACH SIDE SIDE BEAM PLAN VIEW S-2 CARRY BEAM TO UPRIGHT CONNECTION SCALE:NTS DESCRIPTION AS FURNISHED: Lot 34, THORNBROOKE PHASE 1, os recorded in Plat Book 79, Pages .3 _ thru 7, Public Records of Seminole County, Florida. BOUNDARY FOR/CER77FIED T0: Kathleen 1fi. Litzner; Inspired Title Services, LLC; First American Title Insurance Company; The Mortgage Firm REC. 112" I.R. NO 10. �i 48.78' 'A/C 5.00' TRACT K (RECREATION/OPEN SPACE) S 89045' 05" FY 59.40' (CALL.) I I c� I � LOT 34 I I 48.82' I I 40.0' � tT' O O LOT 33 O C6 O T' o o TIYO STORY O v RESIDENCE F.F.=23.02' o t; 4.9, N 5.00' 21.8' 1D R, �i 15' BRICK DRIVE o 13.3" ^ COV 0 BRICK o 19.6' 39.22' BRICK I r- 1iALK ! 0.6' OF-F 'EA G I I I I I 14.40' 0.7! OFF I REC. 112" I.R. r10 10. I1-1 o W Lo m REC. 112" I.R. NO 10. I D=89°55'50" 25.20' R=25.00' - - - -- --- - L=39.24' ?s, 0 10' unL. ES.WT, 1.0, y C=35.33' s9 OF. 16 OFF tiO .s�h CB= S 44'47' i 1 " f , ap 1$ - �2 REC. 518" / LR.:.o to. s' cork. WALK ' ZONIN 0 & DATE REC. '12" J.R. ND Iv. t� -uj Zy- S" ak\ t2' x 25,5` S 89°45' 05" iY 34.43' ConCre+2 Sk0.�o W %-�n S�reeYl Ado 1- o'•�1�� r��,n 4na ins �la-ied r� ti RED ROSE LANE �G�o ti{�``�� (50 R/W) TRACT I wi S'e+b s P 0V-% Pear . C38. 2�1a 1 f?0POSEO = 9NISHE-O SPOT' GRADE ELEVAiIUN PLOT PLO.' AREA CALCULATIONS ER DRAINAGE YtAN1S LOT CONTAINS 7,469 SQUARE FEET aVL0YV_G SLTElACKS. TOTAL IMPERVIOUS AREA = Z564 SQ. FT OR 34,3% FRONT-25' r ^ s PROPOSED DRAINAGE FLOW _ REAR = 15' OT G;2,CIA2; TYPE ,; APPROACtf= 53 Sq. Ft. LEAP 1'lALH= 37. Sq. f't. SIDE = 5.0' ROPOSEU FF PER PLANS = 23.0' SJOFV/ALK= 960 Sq. Ft. DRIV_ 627 Sq. Ft �J SIDE CORNER = 10' USYV AI11IE ETR-AS'COT.7' P P' AT a FIELD PL'L =POINT ON LINE1- IP_ IRON RODPIP - 1R. IRON CD iYP. PAC TYPICAL • POINT OF REVERSE CURVATME C-`i C¢•L-BETE H-Iru.'EIIT F.CE, PAD. - PDIRT OF r"CUND CURVATURE :ET 1"..• UL •/GLS 157E REL RR. • RADIAL w NON AL RECOVERED I.O.D. - PDIRT 7F SLGT`:IUCi P•'L VIR Ct.LC. VI -BADEST pOUIY CALCULATED PHUT TIP COHRElICEF.'EIIT i CRJTERLCJ.T PRH PERMATFAT REFERENCE PO4URENT NAD * !EVIL t DISK T.R &S.L • FDISHED FLOOR ElEVATTCTI BUILDIRO SEFBa LII:E P''d - R;N.T-CF-NAY ESHT. EASEYL:IT OH . BEt2HPARK I-RAIR " ERAIR D.B. • BASE BEARING act UFiL. DTILIIY 'I.S C. = CNAPI ' IN' FENCE VOFG WOOD FEN"E C/D > ED:r_RETE ELa-s P.C. POEM OF CURVATURE P.T. + POINT OF TAI1-.'!CY Past. DESCRIPIIGN RADIUS _ aBC LENGTH D DELTA r. ChCRD C.9 DIM= PCAUNS NORTR T)IJ5 ataL;UtG/pITOp,-R ry DOES.Nor UE Ifl7141N THE ESIlRC15HF.D TGD YEAR FLO^A PIME AS PER FIRM' ZDA:E 'x- MAP ¢ 12117C 0055 F. & A AS1S`OC, .. , ZAI C. - LAND ASlUR IILT.YO 'S` 5400F.. COLONIAL DR. ORLANDO, FL. 32807 (407)-277-3232 FAX (407)--6,5F3- t • 3r &M.S: I, 'HE UNOERS'GIlED DOLT HREOY CfRT1FY IF'AT THIS SURVEY MEETS THE M:t11HUU fiCHh:C'tl STM:I7ARDS SET fCPTH 11Y iFfE FLORIDA BOSCD OF FACFF38:CtUi 'A"'_ SVRI'LYCP,S CI CHVTER W-17 OF THE 11ORIDA ADMI,NISIR47M CODE. 2. Ut.1FSS EMBOSSED RTII! SURVEYCR•S SE,IL• THIS SURVEY IS NOT VAIia Alin IS l'RESEtl7E0 FOR 111FORMATIOU-V PURPOSES 01:LY, J. 1HIS SURIT! {575 PREPARED FROM TIRE ViFGRUAHUI! FURIIISHED TO T)fE SUAVLYOR. THERF. MAY BE OTHER Rc"STNfCI(C'HS f{ av FAs£NERIS TTikT AFTECT THIS PROPMY 4. NO VUVERGROURD a"O SMEMS HAVE 8EF11 LOCATM UNLESS OTFTEPxTSE SHOTiYt. 5. THIS SURVEY LS I'REPAREO FOR THE SOLE BENEFIT OF THOSE CERRRED TO AND SHOULD NOT BE RELIED UPON Ely AtfY OTHER Fttmr. - t OT49lSIOtT.S SH0;55/ Fl`R :IlE LO.AP.Oil OF tMPRG�VEI(TS11 HERFCN SHDUUI wr HE USED TO RECO.RSTRUE. RUWr00TY In, 7. Re'API.4GS ARE WEI) ASSUIITD DATUM MID Oil THE 11.4E SHOf4:4 AS RASE REitR1tIC (OR.) A. £.,EY.ITiONS, 1F 5TJ9NN, :ItF. 8>.SED OV IFAIJO.'!dl GEODETIC 6'ERTICAL IIATUM OF 1929. UNLESS 07HERHISE III, 9. C&TR%ICQ. Or A6QHTIAIZAT70i, Ra, 4598. S01LE 1-_ T• 20'---1 ORM, OY: •,• "------.._ _ CERIIHED BY: caTE------------ - PLOT PLAN 05-30-:5 2137_JS �OL:NpATTRt:/[LENS. 09-09-15 3065- 1.5 FIYAL/ELEVS. Of-05-16 100_ I6 i AODEO CERAiICAT10TIS 03--TG-LG i RaISEO CERTIFICATIONS ONLY 06-DJ-16 7C�f'AS ;f CRUSEtf/l£YF.R. R.L.S. 4.714 I Jfi4l S IV. Scon R.L.S j 4801