Loading...
HomeMy WebLinkAbout716 Cypress Ave.�P CITY OF Building & Fire Prevention Division iki4FORD, PERMIT APPLICATION Application No: Documented Construction Value: $ 12385.00 Job Address: 716 CYPRESS AVE Historic District: Yes❑NoF] Parcel ID: Residential Commercial Type of Work: NewRI Addition❑ Alteration Repair❑ Demo❑ Change of Use❑ Move[ Description of Work: new plumbing for 3 bath / 1 powder bath / kitchen sink ,dishwasher ice maker hook up,washer box / 2 hose bibbs/ 1 water heater Plan Review Contact_ Person: Melissa Wingate Title: schedule manager Phone: 407-291-9364 ex 1 Fax: 407-299-7725 Email: melissa@hqpy.com Property Owner Information Name Phone: v Street: 'Resident of proper City, State Zip: Contractor Information Name Michael R HPhone: olloway/Holloway Quality Plumbing 407-291-9364 . Street: 7050 Edgewater Dr suite G Fax: 407-299-7725 City, State Zip: Orlando Name: Street: State License No.: CFC 1428969 Arch itecVEngi neer Information Phone: Fax: City, St, Zip: E-mail: Bonding Company Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and, installations as indicated. I certify that no work or installation has commenced prior to the issuance; of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc.; FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 61 Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law,,FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date A'(6 Signature of Contractor/Agent Date Ptint,Contracior/Agent's Name /, I I - : State ofFlorida Date �0 Notary Public $tate of Florida Melissa Wingate ,tQ My Commission GG 129602 a �t� Expires 07/30/2021 OwnerlAgerit is Personally Known to Me or Contractor, g nT� lss ersona ly nown o Me or Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas❑ Roof ❑ Construction Type:. Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures _. Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: FIRE: COMMENTS: Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: Revised: January 1, 2018 Permit Application LAOn t" 3 3" 3 H �k'k 3 z Vic; �\3 Ad z� 717 ICY?, --Ss 44tC- .{,A4.4 %V, 7' S z'0Za. h PY 2 „s'TXL WG loc. 2 a 3" z.. �., LAV AV 3'' 3 440 r 3b 3� 3 -� 3 `� 3� we- 2 ,. T+�3 7050 EDGEWATER DRIVE SUITE G ORLANDO, FLORIDA 32810 407-291-9364 FAX:407-299-7725 CFC1428969 CONTRACTOR: UNIVERSAL ROCK CONSTRUCTION SERVICES 17544 DEER ISLE CIRCLE WINTER GARDEN, FL 34787. JOB-: HUDDLESTON :RESIDENCE BASE BID DATE: 12-Dec-l'i GERBER, MOEN. OR EQUAL FIXTURES-AND.FAUCETS QTY . MASTER BATH 2ND FLOOR 1 GERBER ELONGATED WATER. CLOSET BISC WITH SEAT. BRAIDED SUPPLY. 2 GERBER S.R CHINA 19 INCH RDLAVATORY WHITE / MOEN TRIM L64625 CHROME LEVER FAUCET. 1 7901 SCALD GUARD 62300 TL182 VALVE & TRIM MOEN CHROME. 2% SLOPE BY OTHERS. BATH 2 1 GERBER ELONGATED WATER CLOSET'BISC WITH. SEAT. BRAIDED: SUPPLY. 2 GERBER S.R CHINA 19 INCH RDLAVATORY WHITE / MOEN TRIM L64625 CHROME LEVER FAUCET. 1 7901 SCALD GUARD 62300 TL182 VALVE S TRIM MOEN CHROME. 29 SLOPE BY OTHERS. BATH 3 2ND FLOOR 1 GERBER ELONGATED WATER.- CLOSET BISC WITH SEAT.. BRAIDED SUPPLY. 1 GERBER S.R CHINA 19 INCH RD LAVATORY WHITE / MOEN TRIM L64625 CHROME LEVER FAUCET. 1 5FT STEEL BRIGGS TUB BISC WITH 62300 TLI83 CHROME-TRIM.-MOEN POWDER BATH 1 GERBER ELONGATED WATER CLOSET BISC WITH SEAT. BRAIDED.SUPPLY., 1 GERBER S.R CHINA 19 INCH"RD LAVATORY WHITE / MOEN TRIM L64625 CHROME LEVER FAUCET. KITCHEN 1 ROUGH IN AND INSTALL OWNERS KITCHEN SINK WITH '67430 'W SPRAY 1 FURNISH DISPOSALL BADGER 5 I CONNECT OWNERS DISHWASHER WITH SHOCK'ARRES.TOR/ACCOR OONNECTION/DW 90^ ELL FITG 1 COLD WATER LINE TO REFRIGERATOR SPACE". PVC BOX LAUNDRY 2 WASHER BOX. PVC WITH DRAIN WITH SHOCK,ARRESTOR 1 FIRST FLOOR 1 2ND .FLOOR - i SAFTY-DRIP PAN FOR 2ND..FLOOR WASHER WITH DRAIN':TO OUTSIDE MEN 1 50 GALLON RHEEM OR STATE -WATER HEATER 'W PAN W EXPANSION. VALVE AND STAND_. TANK BOOSTER PRO MIXING VALVE INCLUDED.. MISC 2 Outside. Hose Bibs. 1 A.0 CHASE, 4." PVC. ' NOTE: IF BACKFLOW PREVENTOR REQUIRED AT METER .ADD $350.00 TO BID FOR WILKENS 975XL RP BACKFLOW. GRAVITY DWV SYSTEM BID. NO SUMP PUMP IN BID_ CONNECT OWNER'S EXTERIOR SANITARY ,4" 3034 NO ASSESSMENTS NOT OVER 3' DEEP. NOT OVER 40' LONG. NO GAS PIPE OR FLU IN BID CONNECT OWNER'S WATER 1" .PIPE. NO ASSESSMENT'S NOT OVER 40' SANITARY DRAINS,WASTE,VENTS TO BE PVC PIPE. NO FIRE PROTECTION IN THIS JOB 1 TYPE CPVC WITH JOINTS UNDER SLAB. FIXTURES BY OWNER'S SPECIFICATIONS. (NOTE) NO BACKFLOW DEVICE IN BID FOR WATER SERVICE. NO PRESSURE REDUCING DEVICE FIGURED. (NOTE) HOLLOWAY NOW OFFERS BACKFLOW TEST, CERTIFICATION. AT A REASONABLE PRICE IF PRESSURE REDUCING DEVICE IS,NEEDED EXTRA COST: ADD FOR 3/4" $230.00, 1" $250.00,-1-1/2." $270..00. BID DOES NOT INCLUDE METER BACKFLOW DEVICE,OR WARRANTY OF OWNERS FU_RNI.SHED FIXTURES; BID REFLECTS CLEAN HAND DIGGABLE FILL DIRT, NOT ADVERSE DIGGING CONDITIONS HARD DIGGING NOT IN BID ADD $2.00.00. BID DOES 'NOT INCLUDE BACKFILL OF TRENCHES.,BACKF'ILLING BY TRACTOR PROHIBITED.NO IMPLIED WARRANTY OTHER THAN STATED. NO WARRANTY ON QUICK SELF CLOSING VALVES OR THEIR CONNECTIONS. N6TE:IF WATER IS LEFT ON HOME .AFTER FINAL INSPECTION WITHOUT BEING OCCUPIED OR MAINTAINED, HOLLOWAY WILL NOT BE RESPONSIBLE FOR ANY DAMAGES'.YOU NEED.. TO. TURN WATER OFF'.!! HOLLOWAY HAS AVAILABLE AUTOMATED WATER SENSING DEVICE THAT WILL CUT OF WATER. TO YOUR. HOUSE. REQUEST FOR A QUOTE FOR THIS DEVICE. WE CAN NOT WARRANTY WATER DAMAGE WITHOUT THIS DEVICE BEING INSTALLED. SLOPE OF SHOWER FLOORS TO BE DONE BY OTHERS. THERE WILL BE NO HETAINAGE HELD ON THIS JOB. PAYMENT OF CONTRACT AS PER PERCENTAGE OF COMPLETION OF CONTRACT IS DUE WHEN WORK IS COMPLETED., OWNERS SELECTED FIXTURE PACKAGE PERCENTAGE TO BE BILLED ONCE PACKAGE IS SELECTED, AT ALL PHASES. IF OWNER DOES NOT FURNISH OWNER FIXTURES. AT START OF PHASE.. TIME, THEN IT IS DEEMED COMPLETE. NOTE: NO WARRANTY OF JOB IF PAYMENT IS DELIQUENT, IF ICE MACHINE FURNISHED, PLUMBER WILL :NOT BE RESPONSIBLE FOR OWNER NOT MAINTAINING IT:. Bid is only good from start date: for 90 days, Note for material increases. DRAWS AS FOLLOWS: UNDER GROUND 25% $3,096.25 SECOND ROUGH 35% $4,334.75 .FINISH 40% _$4,954.00 CONTRACTPRICE: ---------------------------------------------------------------------------------------------------- $1'2,385.00 In the event that any phase of this contract goes more than 30 days without completion, a draw of 50% of that phase will be immediately due. Peae - I Pricing is based on payment by cash or check. We accept credit cards for an additional 4% 'charge. 'ff. M a.17," Building & Fire Prevention Division PERMIT APPLICATION Application No: I? U 1 s' Documented Construction Value: $ 1 1 AH ?I ' Job Address: 716 Cypress Ave Parcel ID: Type of Work: New❑✓ Addition❑ Alteration Repair Demo Description of Work: New Construction Electric 11 o`� oo Plan Review Contact Person: Phone: Fax: Email: Property Owner Information Name Jeff Huddelston & Lorraine Savage Phone: Street: 716 Cypress Ave City, State Zip: Sanford, FI. 32771 Historic District: YesF—]NoF] Residential® Commercial Change of Use❑ Move Resident of property? : Contractor Information Name Terry's Electric, Inc Street: 600 N Thacker Ave Ste A City, State Zip: Kissimmee, FI. 34741 Name: Street: City, St, Zip: Bonding Company: Address: Phone: 407-572-2127 Fax: State License No.: EC0001018 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 61" Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date i o n . C_ ate fj�- Neu Print Owner/Agent's Name P mt ontractor/Agent's Name Signature of Notary -State of Florida Date Signature of Notary -State o Florida Date Owner/Agent is Personally Known to Me or Contractor/Agent is ersonally Known to Me or Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing[] Gas[] Roof ❑ Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Flood Zone: # of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: Revised: January 1, 2018 Permit Application Subcontract Agreement This agreement is between Universal Rock Construction Services Corporation (URCS) 17544 Deer Isle Circle, Winter Garden, FL And Subcontractor: Terry's Electric Incorporated 600 N. Thacker Ave. Kissimmee, FL Date: January 9, 2018 Project Name: Huddleston Res. Project Address: 716 Cypress Ave. Sanford, FL Description of work to be aerformed: Electrical Work 1. The subcontractor shall complete the electrical work for the Huddleston project per local and state building codes. The work shall comply with Industry standards. The subcontractor shall provide supervision, tabor, equipment and sundry items to complete the work. All work shall comply with OSHA safety standards. Should the subcontractor be absent from the project for more than three (3) working days when scheduled to work without written approval from the General Contractor this contract may be terminated. The electrical work shall include but not be limited to the following. Main Service, Main Panel, outlets, wiring, vent fans, ceiling fan pre -wire, phone and cable wiring, rough electrical, trim electrical, can lights, etc.. The subcontractor shall also coordinate with other subcontractors working on the project. All work shall be completed per plans, specifications and other contract documents Sheet A,1,2,3,4,5 and 6 on drawings developed by John Pilkey and Associates, Inc. dated 11-20-2017. Should the work fail to meet the above mentioned guidelines, the subcontractor must correct faulty work or be liable for the cost of corrective measures. Payment Schedule: 70%- Rough 30%- Trim, Total Cost: $11,648.00 Contractor's Signature: Date: ¢" 5— l? Subcontractor's Signature: Ru� Date: Subcontractor Agreement a-t� .......... ........ :1 .......... ...................... p ......... i .......... wp.e ....... ................................................ t .............. m� ....... ................ THIS AGREEMENT made and entered into by and between Universal.Rock Construction Services Corporation , hereinafter called the Contractor, and Armstrong Air and Heating, Inc., hereinafter called the Subcontractor. WITNESSETH: The Contractor, for the full, complete and faithful performance of this subcontract, agrees to pay to the Subcontractor, in accordance herewith, the sum of Ten Thousand Seven Hundred One Dollars and 00/100 ($10701.00) payable as follows: 100% After completion of the Framing work. In consideration therefore, the Subcontractor agrees as follows: 1. To furnish all supervision, labor and equipment, to perform all work as described in Paragraph 3, and in accordance with all plans, specifications and other contract documents Sheet A,1,2,3,4,5 and 6 on drawings developed by John Pilkey and Associates, Inc. dated 11-20-2017 bid on for the project known as: Huddleston Residence on 716 Cypress Ave. Sanford, FL 2. N/A 3. That the labor and materials to be furnished, and the work to be performed by the Subcontractor are as follows: Signed this I D d y of J Ate, 20 t Signature of Contractor: Signature of Subcontractor: (PROVISIONS PRINTED ON ALL PARTS OF THIS AGREEMENT ARE BINDING UPON THE PARTIES) THE SUBCONTRACTOR AGREES: HVAC Subcontractor agrees to furnish all labor, materials equipment and other facilities required to complete the following work: Provide all labor, permitting, materials, equipment, supervision, hoisting equipment and sundry items to complete the work. The work shall include but may not be limited to the following: duct work installation, upstairs and downstairs (Two) 15 SEER condenser units, upstairs and downstairs (Two)15 SEER air handler units, thermostats, vent grilles, bath fans and venting material, dryer vent, exterior vent caps. All equipment shall be carrier or equal. All work shall be completed per local and state building codes, OSHA safety standards and to the owner's satisfaction, architects intent and per the manufacturer's instructions. This contract also includes a blower door test and report. (a) To assume toward the CONTRACTOR, so far as the SUBCONTRACT work is www.socrates.com Page 1 of 3 LF325 -I- Rev, 02/05 concerned, all the obligations and responsibilities, which the CONTRACTOR assumed toward the OWNER by the MAIN CONTRACT, which includes the general and special conditions thereof, and the plans and specifications and addenda, and all modifications thereof incorporated in the documents before their execution (which documents shall be available to the SUBCONTRACTOR). The SUBCONTRACTOR agrees not to assign or sublet said work or any portion thereof without the written consent of the CONTRACTOR. (b) To start work when notified by the CONTRACTOR, and to complete the several portions and the whole of the work herein sublet, at such times as will enable the CONTRACTOR to fully comply with the contract with the OWNER, and to be bound by provisions in the MAIN CONTRACT with the OWNER for liquidated damages, if caused by SUBCONTRACTOR. (c) To submit to the CONTRACTOR applications for payment at such reasonable times as to enable the CONTRACTOR to apply for and obtain payment from the OWNER, and to receive as progress payments from the CONTRACTOR the amounts allowed to the CONTRACTOR by the OWNER on account of the SUBCONTRACTOR'S work to the extent of the SUBCONTRACTOR'S interest therein. Final payment shall be made within a reasonable time after the completion and acceptance of the subcontract work unless a definite time for final payments is fixed on the face thereof. (d) The CONTRACTOR may, without invalidating this SUBCONTRACT, order extra work or make changes by altering, adding to, or deducting from the work; the price herein being adjusted accordingly. All such work shall be executed under the conditions hereof, and of the MAIN CONTRACT, except that any claim for extension of time caused thereby must be agreed upon at the time of ordering such change. (e) To make no claims for extras unless the same shall be fully agreed upon in writing by the CONTRACTOR prior to the performance of any such work. (f) The CONTRACTOR has the status of an employer as defined by the Unemployment Compensation Act of the State, and all similar acts of the National Government, and including all Social Security Acts; that he/she will withhold from his/her payrolls the necessary Social Security and Unemployment reserves, and pay the same; that the CONTRACTOR shall in no way be liable as an employer to or on account of any of the employees of the SUBCONTRACTOR; that the SUBCONTRACTOR will as an employer, to the extent of any of his/her employees under this contract, conform to all rules and regulations of Social Security Acts and Unemployment Commissions created by said laws, and that he/she will furnish satisfactory evidence to the CONTRACTOR that he/she is conforming to said laws, rules and regulations. The SUBCONTRACTOR hereby releases and indemnifies the CONTRACTOR from any and all liabilities under said laws. (g) That the SUBCONTRACTOR will pay any and all federal, state and municipal taxes and licenses, including sales taxes, if any, for which the SUBCONTRACTOR may be liable in connection with the labor and materials herein, or in carrying out the SUBCONTRACT, prior to final payment being made to him/her. (h) To pay industrial insurance and all other payments required under Workmen's Compensation laws as the same become due, and to furnish the CONTRACTOR with evidence that the same has been paid before final payment is made on this SUBCONTRACT. (i) That all materials delivered by or on account of the SUBCONTRACTOR and intended to be incorporated into the construction hereunder shall become the property of the OWNER as delivered; but the SUBCONTRACTOR may repossess himself/herself of any surplus remaining at the completion of his contract. That all scaffolding, apparatus, ways, works, machinery and plans brought upon the premises by the SUBCONTRACTOR shall remain his/her property, but in case of default and the completion of the work by the CONTRACTOR, the latter shall be entitled to use the said scaffolding, apparatus, ways, works, machinery and plans without cost or liability for depreciation of damage by use and without prejudice to CONTRACTOR'S other rights or remedies for any damage or loss sustained by reason of said default. wwwsocrates,com Page 2 of 3 LF325-1•Rev. 02/05 0) In the event the contract herein is upon a unit price, it is understood and agreed that any quantities and amounts mentioned are approximate only and may be more or less at the same unit price and subject to change as ordered and directed by the CONTRACTOR. Subcontractor shall provide proof of General Liability and Worker's Compensation Insurance. (k) To indemnify and save harmless the CONTRACTOR from and against any and all suits, claims, actions, losses, costs, penalties and damages, of whatsoever kind or nature, including attorney's fees, arising out of, in connection with, or incident to the SUBCONTRACTOR'S performance of this SUBCONTRACT. (1) To immediately, after receiving written notice from the CONTRACTOR, proceed to remove or take down from the grounds or buildings, all materials condemned by the CONTRACTOR whether worked or not, as unsound or improper, or as in any way failing to conform to the MAIN CONTRACT, including the general or special conditions, drawings, specifications or addenda. Failure of the CONTRACTOR to immediately condemn any work or materials as installed shall not in any way waive the CONTRACTOR'S right to object thereto at any subsequent time. (m) To commence and at all times to carry on, perform and complete this SUBCONTRACT to the full and complete satisfaction of the CONTRACTOR, and of the Architect or OWNER. It is specifically understood and agreed that in the event the CONTRACTOR shall at any time be of the opinion that the SUBCONTRACTOR is not proceeding with diligence and in such a manner as to satisfactorily complete said work within the required time, then and in that event the CONTRACTOR shall have the right, after reasonable notice, to take over said work and to complete the same at the cost and expense of the SUBCONTRACTOR, without prejudice to the CONTRACTOR'S other rights or remedies for any loss or damage sustained. (n) Upon completion of any unit of the work, and upon final completion thereof, to clean up all refuse and rubbish, same caused by the SUBCONTRACTOR, and to promptly remove all excess material, tools, structures, etc., which may have been brought on the premises or erected by the SUBCONTRACTOR, and in the event of the failure of the SUBCONTRACTOR so to do, the CONTRACTOR may, after reasonable notice to the SUBCONTRACTOR, clean up the premises at the cost and expense of the SUBCONTRACTOR. www„socrales.com Page 3 of 3 LF325-1• Rev, 02105 Revision ❑ Response to Comments Permit # < 5 Project Address: JUL 'ML__ ----- Submittal Date Contact: 6(---61-T 1" � J- K:ES Ph: V 3 Fax: Email: %2 (' L eEk::� <�2- Trades enc passed in revision: Building ❑ Plumbing ❑ Electrical ❑ Mechanical ❑ Life Safety ❑ Waste Water Department. ❑ Utilities ❑ Waste Water ❑ Planning ❑ Engineering ❑ Fire Prevention Lf Building City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov r7-1Z- /0V General description of revision: id Zw C) /-/ 9,5s, 1,1T %j ROUTING INFORMATION Approvals C� 1• �6�t P RECORD COPY 5pencer N.Robinson, P.E. Iorlda Royi®tratlon No. 81250 S I UCtUI 4L ENGIN E ING INS. Industrial, Commercial 8 Residential Office 863.815.a541 1121 Shadow Drive Cell ab3.b60.8012 5vits 3 Fox 863.855.11861 Lakeland, IL 3380q 5-mail: mrob(nron24@5tr-eng.rom .� aW.� � � ,,��; gig% � • JUL 17 2018 .' r'Br:_ DATE: 7/11/201P TO : G 1 TY OP SANFORD E3U I LD I NCB DEFARTMENT RE: PERMIT 40-675 HUDDLESON RESIDENCE 716 G' FRESS AVE. SANFORD, FL. 52711 UN I VERAL ROG< GONSTRUGT I ON THIS OPF I GE APPROVES THE FOLLOK NCB : TRUSS STRAP GHAN67E FROM 5I MPSON HT520 TO S I MP50N (2) H2 5 A EAGH 51 DE OF TRU55 (E30TH END) AND TO TOP PLATE. Natrerj�i r ; G � ...R61'r r .0 • No 81250 2 . r 4 STATE OF � 4e/ ; r 40 S Ca 00\LDI/UG SANFORD 2&N F)'AR� `�.