Loading...
HomeMy WebLinkAbout1569 Travertine TerD"-r�9�iE MAR 2 7 20 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: /'9- /S Documented Construction Value: $ 3,925.00 Job Address: 1569 TRAVERTINE TER SANFORD, FL 32771 Historic District: Yes ❑ No ❑ Parcel ID: 33-19-30-520-0000-1290 Residential X❑ Commercial ❑ Type of Work: New ❑ Addition ❑ Alteration n Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: Replace existing 2.5 ton Heat Pump system with new 14 SEER AC heat pump system 5 KW supplimental heat strip Plan Review Contact Person: Steven Perry Title• Owner Phone: 407-388-1300 - Fax: 407-210-8852 Email: steven@electricool.com Property Owner Information Name MOORTHY MAHADEVAN, Phone: 407-314-6809 Street: 2110 ROLOND GLEN RD City, State Zip: CARY , NC 27519 Resident of property? : No Contractor Information Name ElectriCool Inc / Steven H Perry Phone: 407-388-1300 Street: 733 S Edgemon Ave Fax: 407-210-8852 City, State Zip: Winter Springs FL 32708 State License No.: CAC1817352 Name: Street: City, St, Zip: Bonding Company: Address: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5th Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application D D I I I NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Signature of Contractor/Agent Date Steven H actor/Ag is Name �7 Si `7iSfai-State ofFlonda--- ate LISA APITCFJINI ?; Public - State of Florida _ Wn. Fxr ies May 21, 2018 o ;nis,, n # FF 125242 Contractor/Age�]t� s Personally no to Me or Produced ID V Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas ❑ Roof ❑ Construction Type: Occupancy Use: Flood Zone: _ Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application PropgnyBecoACard _ Parcel: Property Address; 1569 TRAVERTINE TF..R SAN FORD. RL 327711, ElectriCool Inc. Proposal 5703 Red Bug Lake Road Suite 322 Winter Springs, FL 32708-4969 (407)388-1300 steven@electricool.com http://electricool.com Porzig Realty 1569 Travertine Terrace, Sanford Sanford, FL 32771 JOB LOCATION 1569 Travertine Terrace, Sanfor The AC system is starting to have problems, the air handler in the attic is showing signs of a refrigerant leak, the drain pan is got oil staining and the refrigerant was a little low, added reclaim refrigerant to get the system running properly. The outside AC heat pump compressor motor is making strange noises, sounds like something coming apart internal, the system is 13 years old, cost to replace the evaporator coil and the compressor motor would not be worth the expense with the system as old as it is, the parts would only come with a 1 year warranty also. 1) Remove and discard off property all existing heat pump equipment as per EPA requirements. 2) Install new secondary drain pan to accommodate new air handler. 3) Make connections to existing duct -work. 4) install new 4" thick concrete pad and anchor down new heat pump unit as per building code. 5) Replace thermostat with digital programmable type 6) Re -use existing electrical wires and breakers, change breakers to match equipment if required. 7) 5-year parts warranty. 8) 1-year labor warranty. .......... Phone# 407-388-1300 TOTAL Fax# 407-210-8852 HVAC Lic# CAC-1817352 Elec. Lic# EC-13006674 1 3,925.00 Accepted By Accepted Date Phone# 407-388-1300 Fax# 407-210-8852 HVAC Lic# CAC-1817352 Elec. Lic# EC-13006674 3,925.00 $3,925.00 �l I ® lT. Certificatef Product Ratings AHRI Certified Reference Number: 7947635 Date : 03-27-2018 Model Status : Active AHRI Type: HRCU-A-CB Outdoor Unit Brand Name: AMERISTAR Outdoor Unit Model Number (Condenser or Single Package) : M4HP4030A1 Indoor Unit Model Number (Evaporator and/or Air Handler) : M4AH4032A1000AA The manufacturer of this AMERISTAR product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 29000 SEER : 14.00 EER (A2) - Single or -High Stage (95F) : 11.65 Heating Capacty (H12) Single or Hlgh Stage,::(47F) 28600 HSPF (Region IV) ,8 30 t.; t f . P 2S'" ; TM3 4 { E ! #..+.wsM4 1 @ : i A 3 v c y r r } x�p'� } " �8-a r tM��f tt P� t :l tH s t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being prod uced."Prod uction Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re -rate. The new Dublished rating is shown alona with the previous (i.e. WAS) ratina. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and AM, confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridlrectory.org, click on "Verify Certificate" link we make life better - and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right.i 131666309348355803 ©2018Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: