Loading...
HomeMy WebLinkAbout182 Walnut Crest Run (2)=6r«1CITY OF S�,NFORd � F I �Rt D E �PA R T M A Building & Fire Prevention Division PERMIT APPLICATION Application No: / y _ I d / y �( On J T Documented Construction Value: $ q I? _ Job Address: "Of5i at),A-/ Historic District: YesF]Noa Parcel ID: Residential Commercial Type of Work: New❑ Addition❑ Alteration Repair Demo ❑ Change of Use❑ Move ❑ Description of Work: Plan Review Contact Person: Title: Phone: Fax: Email: Property Owner Information Name Phone: Street: 2 2 i r CvAg e A- 14 S f =1r_' L%� .D Resident of property? City, State Zip: fi iL _47- fir- Zs�c Contractor Information Name Phone: L-72crcp -) f 0 q Street: 1 S j 2F71 n n a Q Fax: City, State Zip: C tee) a Yqcl = State License No.: 02t A2_\`1� 1� Name: Street: City, St, Zip: Bonding Company: Address: Arch itect/E ng I neer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 61^ Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property of the requirements of Florida Lien Law, FS 713, The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Sio6turc 6fOvi)5ffA&cat Date Signature o ontractor/Agent Date r �� Print Owner/Agent's Name Prin ontract r/Agent s Name �t \ \ l Signature - n_• Signatur ,1+>rgY&{ ;State of Fk9E*E FLANTON Datcl' . o: CHARLOTTE A MILES _,: MY COMMISSION # 1'F t7as4a I MY COMMISSION #F FF985939 P EXPIRES: February25, 2019 �, EXPIRES June 19,2020 t3ontledThru Notary Public ('107;19iea-01,53 F10r,1,tuotar Sarvke;tam Owner/Agent is Personally Known to Me or Contractor/Agent is Personally Known to Me or Produced ID ✓ Type of ID Jll V e_J' ( c4n f e Produced ID Type of ID L s BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas❑ Roof ❑ Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads Fire Alarm Permit: Yes ❑ No ❑ APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: COMMENTS: Revised: January I, 2018 Permit Application 2/20/2018 SCPA Parcel View. 22-19-30-502-0000-1880 o cyt Property Record Card �P Parcel: 22-19-30-502-0000-1880 scnarucx.cr�rrrv,oann Property Address: 182 WALNUT CREST RUN SANFORD, FL 32771 Parcel Information Parcel 22-19-30-502-0000-1880 Owner OFFERPAD (SPVBORROWER5) LLC Property Address 182 WALNUT CREST RUN SANFORD, FL 32771 Mailing 2212 E WILLIAMS FIELD RD BLDG 11 #225 GILBERT, AZ 85295- 0771 Subdivision Name PRESERVE AT LAKE MONROE Tax District S3-SANFORD-WATERFRONT REDVDST DOR Use Code 01-SINGLE FAMILY PyPmntinng nn_HQhAFCTFAn/ n1 1 LO 9 A Legal Description LOT 188 PRESERVE AT LAKE MONROE PB 62 PGS 12 - 15 a_ _._____..._ _.._.___.___ Taxes ram ^ V O LO Seminole County GIS Taxing Authority Assessment Value i Exempt Values Taxable Value County General Fund —-- V�— $142,573 $50,000 $92,573 __.-_—_.............__._.._._.. __._.. ___.. _ ._..---._.. Schools __..___. _._......... _..._._ _._._ $142,573 ± $25,000 $117,573 City Sanford $142 573 ' $50,000 $92,573 SJWM(SaintJohns Water Management) $142,573 ' $50,000 $92,573 County Bonds $142,573 ; $50,000 $92,573 Sales Description Date Book Page Amount Qualified Uac/Imp WARRANTYDEED 1/1/2018 ! 09061 0892 $209,000 i Yes 1 Improved WARRANTYDEED 12/1/2009 07318 ; 0829 $160,000 ! Yes I I WARRANTYDEED j 6/1/2005 05867 1476 $265,000 Yes I Improved WARRANTYDEED 7/1/2004 ` 05415 1738 $169,100 Yes Improved Rnd Comptarabb Sates Land Method Frontage Depth Units Units Price Land Value LOT — 1 ,i $40,000.00 $40,000 NBuilding Information Is Bed/Bath count incorrect? Click Here. http://parceldetaiI.scpafl.org/ParcelDetaiIInfo.aspx?PlD=22193050200001880 1/2 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: atke> . I hereby name and appoint: V N antra S s� \ A\ a an agent of: t-- AY (Name to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): VI The specific permit and application for work located at: (Street Address) ^ (� Expiration Date for This Limited Power of Attorney: (9L "1 License Holder Name: State License Number: Signature of License Holder: STATE OF FLORIDA COUNTY OF The foregoing instrument as acknowledged before me this aday of 200 j�, by 0y--\ who is personally known to me or ❑ who has pr duced identification and who did (did not) take an oath. Sinature U `':0A�,ssiory ���irmt or type name �•�O pH 10, o 2 OF 100263 a�a f`m 9'!l �hiic UVO O �� O � � (Rev.6.'•��� Notary Public -State of Roo dc, Commission No. F�-_ JCN�LL03 My Commission Expires: AlkZ1 1 as L-7;�' e�� �5k�K HEATING & AIR CONDITIONING 1512 E. GARY RD LAKELAND FL 33801 ORLANDO 407-COOLING-TAMPA/LAKELAND 863-940-9800 www.404COOLING.COM 02/19/2018 OfferPad 182 Walnut Crest Run HVAC Sanford FL, 32771 • Electric split system 3 ton (R-22) • The air handler is 14 years old in poor condition. The interior evaporator coil fins are very brittle, extremely dirty showing signs of rust causing it to clog and restrict its capacity preventing heat/cooling transfer and will cause a 20-40% drop in performance ultimately causing the coil to fail prematurely. The evaporator coil is leaking at a capillary tube. • The AC is 14 years old in poor condition. The exterior condenser coil fins are damaged and are affecting the performance of the system. The system has reached its life expectancy. • Ductwork is in fair condition; use existing supplies, use existing returns • 150 AMP panel; Service completed: Diagnostic $59.00 (waived for replacement) Pull and clean blower assembly $89.00 Cleared drain line $31.00 Leak search $149.00 Service option #1: Replace evaporator coil $1,931.00 10lbs of R22 $790.00 Total: $3,049.00 3-ton HVAC system includes the following: 3-ton outdoor unit 14 SEER with R-410A refrigerant 3-ton air handler with 5KW heat strips Ductwork (tie intoexisting) Digital Thermostat Low & high voltage (high voltage is supplied by the customer) Mastic seal joints at system Remove existing & discard Hurricane Pad for outdoor unit Hurricane tie downs Includes all labor & material to complete job Mechanical permit (electrical permit not included) Costs• Above system $3,350.00 Incurred cost $149.00 Total: $3,499.00 Eric Medina National Accounts Manager Air Conditioning Experts Office: (404) COOLING FAX: (770) 921-2198 CELL: (678) 637-3382 � 1,, 1 !�J : 1�qi 111111111 iTqtullo[;� r-Titrull L :. - 0 - I i� 11111L AHRI Certified Reference Number: 201644607 Date : 02-22-2018 Model Status : Active Old AHRI Reference Number : 7995253 AHRI Type : HRCU-A-CB Series : GSZ14 Outdoor Unit Brand Name : GOODMAN Outdoor Unit Model Number (Condenser or Single Package) : GSZ140361 K* Indoor Unit Brand Name : Indoor Unit Model Number (Evaporator and/or Air Handler) : ARUF37C14A*+TXV Furnace Model Number : The manufacturer of this GOODMAN product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity ,(A2) - Single or High Stage (95F), btuh : 34600 SEER: 14.00 EER (A2) - Single or High Stage (95F) : 11.50 Heating Capacity (H12) -Single or High Stage (47F) : 32800 HSPF (Region IV) : 8.20 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratinas that are accompanied by WAS indicate an involuntary re -rate. The new published rating is shown along with the previous (i.e. WAS) rating. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and ,2 24-1 confidential reference purposes. The contents of this Certificate may not, In whole or In part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The Information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make lire better - and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which is listed above, and the Certificate No., which is listed at bottom right. ©2018Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 131637818138715000