Loading...
HomeMy WebLinkAbout2407 S Sanford Ave (3)0 1 S]�iM1Ty a FEB 2 2 2018 Building & Fire Prevention Division NFORDH PERMIT APPLICATION FIRE DEPARTMENT Application No: Documented Construction Value: $ 5,500.00 Job Address: 2407 S. sanford Ave Sanford FL 32771 Historic District: Yes ❑No❑ Parcel ID: 31193151700000050 Residential Commercial❑ Type of Work: New[] Addition[] Alteration ❑ Repair RI Demo ❑ Change of Use❑ Move ❑ Description of Work: Foundation Stabilization two pins on the back left side of the house and two on the right side of (UTF) Middle of the house Plan Review Contact Person: Silvia Rodriguez Phone:3525934141 Fax:3525934151 Title: Office mananger Email: FRSLLC.TM@GMAIL.COM Property Owner Information Name Short Street Investments, LLC Phone: Street: 4300 W. lake Mary Blvd Suite 1010 City, State Zip: Lake Mary, FL 32746 Name Rafael Rodriguez Street: 18766 Cortez Blvd Resident of property? : Contractor Information City, State Zip: Brooksville FL 34601 Name: Sinkhole Geotech Street: 21859 State Road 54 City, St, Zip: Lutz FL 34610 Bonding Company: Address: Yes Phone: 352-593-4141 Fax: 352-593-4151 State License No.: CRC1331016 Architect/Engineer Information Phone: 813-312-0090 Fax: E-mail: admin@sinkholegeotech.com Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a pennit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces,"boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6" Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. ) L 0 1., 1,0 E ( - Signature of Owner/ gent Date AC61 6KWI Print Owner/Agent's Name 1-31- jig Si re of Notary -State of Florida Date �pv ode o ;. JONATHAN MCDONALD •? MY COMMISSION #FF112805 '•'for'`' EXPIRES April 15, 2018 Owne ° sa tto 4e or Produced ID Type of ID " //, J k�- / -3l --2-1 g Siga e of Contractor/e-t Date Print Contractor/Agent's Name ature of lfotary-State of Florida Date JONATHAN MCDONALD MY COMMISSION #FF712805 "'••,'F�......'��'-!!!o°:•' EXPIRES April 15, 2018 Contra FlorlcRIS el "wn o Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas❑ Roof ❑ Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads Fire Alarm Permit: Yes ❑ No ❑ APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: 5V7 9.7-1 COMMENTS: Revised: June 30.2015 Permit Application State of Florida ' County of Seminole 4 Permit Number: Parcel ID Number: 31193151700000050 a The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following Information is provided in this Notice of Commencement, �o Tou °pjparK sanfior�da ` t� ` 8 ' an straeave an>or� 32771 VaRttILaDtIonRof t�°e" OF IC . eof sd�e of the house and right side middles of the house w r7 Z u-, u .._I 1 /I rl LrI ` I CI C)A= mr�r3� Uj — , 1+:1 ,-+ .!a Ld t w ri N U,. ,:.t L'- I C , 7� C7 W L—d rt LI Cu 41- Ce O C-1 r_ 1 [CUJ W:..?C„•C C. CCJ:4—.iLdWW OWNER -INFORMATION: -- - - _._. Name: Michael`Dumen Address: 291. Short st Lake Mary FL 32746 n rev ne Yue error r uT r nr lot 0 Fee Simple Title Holder (If other than owner) Name:- Fee Sltriple A,'40 COMPTROLLER Address: se19!i111BtE cc) Uf 'fI $Y CONTRACTOR: Name:- Rafael R. Rodriguez/Titan Foundation Repair Specialist Address: 18766 Cortez Blvd .Brooksville FL 34601 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: Address: In addition to himself, Owner Designates of To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date Is 1 year from date of recording unless a different date is specified) INAgNiNG TO `O NER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT;ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES; AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF . COMMENCEMENT MUST BE , RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT, Under penalties of. perjury, I declare that i have read the foregoing and that the facts stated in It are true tot b o y knowledge and belief. c Ow" ignatum Owners Printed Fkxida Statute 713.1 1)(g): kThe owner must sign the notice of commencement and no one else may be pe to sign in his w her stead• - State of — C1o.1 County of , `-� )-n I n The foregoing Instrument was acknowledged before me this l day of bX <' Who is personalty known to me ❑ Name of person making tement OR who has produced identificationtype of identification produced: JONATHAN MCDONALD =•i • MY COMMISSION #FF112805 °�f EXPIRES April 15, 2018 � ary Signature (407) 39"153 FtoridallotaryService.com 18766 Cortez Boulevard o Brooksville, Florida 34601 c Office: 352.593.4141 a Fax: 352.593.4151 3 �s41tc,* C-L-6 SinkholeTitan.com s(0-1010 t+309 DATE: %� NAME: ADDRESSv9,gL PHONE: EMAIL: • ® • e e Steel Piers G� 7 � o s $ Pier Depth Exceeding Proposed Depth $ Interior Piers $ Interior Pier Depth Exceeding Proposed Depth $ Slab Piers $ Slab Piers Exceeding Proposed Depth $ Spreader I -Beams $ Remove and Replace Concrete $ Chemical Grout $ Permit t'�"v J� $ SL) 6 Engineering Fee / �� c?6 / , $ 3 01 Service Other: Lj Total Estimate Cost Range: 1 �1 $ J C-06 TERMS OF PAYMENT: 30 % Deposit Due upon acceptance of proposal. Balance of contract due upon completion. Owner agrees to pay cost of collection should any action be taken to collect any/all amounts due and unpaid, to include court cost and attorneys fees. Cosmetic repairs such as patching and painting are not included in the proposal. Titan will make every effort in the performance of our work to prevent or minimize damage that could result from repairs. Titan is not responsible for interior or exterior damage to windows, doors, tile, drywall, paneling, appliances, roofing, HVAC, landscaping or plumbing, etc. Any additional costs incurred for removal and/or replacement of HVAC, electrical, plumbing, sewer, pool equipment, sprinkler system, utilities, or any other underground unknowns are not included in this proposal, unless specified, and will be an additional expense. No allowance is included for dealing with previous foundation repair efforts by others or design changes there of. Titan Complies with FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001-713.37, FLORIDA STATUTES) If this contract should be breached after the allotted time frame, Titan Foundation Repair Specialist, LLC, as the Contractor, is entitled to recover any and all applicable fees, (which include, but are not limited to, documenting fees, labor, travel, or equipment, to complete any portion of the contract), plus $2,000.00 or 10 % of the contract's value, which ever may be higher. Additionally, we, the Contractor, will not be held liable for any cost incurred by any legal action associated with the breach of his co tract. Thank you for considering us for s p of t. If a can be of further service please do hesitate to contact us. This proposal is goo or 30 ays. CUSTOMER SIGNATURE: DATE: v '� RECORD COPY CITY OF DEPARTMENTFIRE To: Sinkhole Titan Foundation Repair Rafael Rodriguez 18766 Cortez Blvd Brooksville, FL 34601 Re: Foundation Repair 2407 S. Sanford Ave Sanford, FL 32773 BP# 18-1014 March 21, 2018 Building & Fire Prevention Division FOUNDATIONREPAIR Please be aware that the Building Official requires an affidavit from the Engineer of record for the final inspection for the stabilization of the building's foundation. No inspections will be performed` by the Building Department. When work is complete, please provide the Building Department with a signed and sealed affidavit from the Engineer of record indicating a positive conclusion for the final inspection to complete this permit. Whenever a permit is issued in reliance upon an affidavit or whenever the work to be covered by a permit involves installation under conditions which, in the opinion of the building official, are hazardous or complex, the building official shall require that the architect or engineer who signed the affidavit or prepared the drawings or computations shall supervise such work. In addition, they shall be responsible for conformity to the permit, provide copies of inspection reports as inspections are performed, and upon completion make and file with the Building Official a written affidavit that the work has been done in conformity to the reviewed plans and with the structural provisions of the technical codes. In the event such architect or engineer is not available, the owner shall employ in his stead a competent person or agency whose qualifications are reviewed by the Building Official. The Building Official shall ensure that any person conducting inspections is qualified as a building inspector under Part III of Chapter 468, Florida Statutes. Sincerely, Steve Fiorey, CBO Deputy Building Official City of Sanford 407.688.5065 steve.fiorey@sanfordfl.gov Subsidence Investigation Summary SINKHOLE GEOTEC , INC. Geotechnical & Structural Consulting Mailing Address: 21859 State Road 54, Lutz, FL 34639 Homeowner MOORE, MARY F Address ` 2407 5 SANFORD AVE, SANFORD, FL82771 Parcel ID 31-19-31-517-0000-0050 Legal Description LOT 5 SOUTH PARK SANFORD SGT Project No. SGT- F1802-91136 Permit No. i Investigation Findings Sinkhole Geotech (SGT) was requested to check this residence to recommend the appropriate remediation for the damage. SGT inspected the residence to study the nature and potential causes of the damage. The damage to the residence is cosmetic in nature. To the best of my knowledge, there no previous foundation work has been done. With only a visual foundation inspection, the damage seem to be a result of long-term post construction movement and for shrinkage or expansion cracks. The most significant damage is the hairline cracks in two corners. The purpose of this Soil & Structure Assessment completed by SGT for the project site was to evaluate the foundation and determine if the residence is stabilized and habitable at this time. A two -stage engineering investigation was performed which consisted of the elements listed below. Stage I • Performing a field inspection of the residential structure, selecting field test locations, and reviewing existing information consisting of general subsoil conditions in the project area and any other available project area related information. Stage II • Evaluating the exterior and interior damage, if any, • Obtaining representative soil samples from test locations, if needed, ® Grouting or filling all soil borings in general accordance with applicable guidelines, as necessary, s Reviewing soil samples of all selected samples, as necessary, to evaluate pertinent engineering characteristics of the soil and assist in their classification, and; o Compiling the field exploration data, providing an evaluation of sub -soil conditions and summarizing comments, findings, and conclusions as they relate to the completed repair, ongoing damages on the property. : 6 . ,) .. --mend,,:a n: -—diativ- The observed damage is consistent with differential movement of the foundation due to lack of support from underlying soils. SGT was requested by the homeowner and/or his contractor to provide a partial remediation plan. A remediation consists of 4 underpinning points as requested by homeowner/homeowner contractor. The depth of the underpinning piers is a function of the pressure exerted to barely lift the wall without damaging it. The underpinning transfers the house load to more stable deeper soil and prevents further foundation movement. Estimated total cost is in the range of $5,000 to $8,000. Respectfully, SINKHOLE G EOT£CH, INC. Ahmed Said, P .D., PE Principal Engineering Consultant Florida License Number: 70901 Existing masonry exterlo wall to remain ASSUMED LOADS r & —1 Vertical Loads Dead Live Wind Roofx(house width) 10 20 2 Floorx(house width) 30 40 n/a Grade Beam plf 80 n/a n/a Wall plf 531 n/a n/a Ceiling plf 113 n/a n/a Gable Ends -If 99 n/a n/a PRESSURE PIER BRACKET DETAILS Drawing not to scale For Clarification purpose only Similar system can be used For more information see Said 2014 PRE3WRE PIER SPECIFICATIONSCOMPCOMPUAWE TH FASS P LICA UP UNDERPIN APPROACH A STABILI T IVE APPROACH WLL BE USED TO STAMUZE THE STRUCTURE IN ITS CURRENT CONDITION WHILE LIMITING THE POTENTIAL FOR COLLATERAL DAMAGES VAICH COULD RESULT FROM UFTINO PREPARE THE BEARING AREA UNDER THE FOOTNG TO A LEVEL CONDITION, AND ADJUST THE FACE OF THE FOOTER AT THE POINT OF BRACKET ATTACHMENT ATTACH THE DRIVE STAND AND THE HYDRAULIC CYUNDER TO FORCE THE PIER PIPE INTO THE SOL AND MOUNT ON THE ORIVE STAID ADVANCE THE PIER PIPE INTO THE SOIL USING THE STRUCTURE AS THE REACTION FORCE WTHA I(I PSI DUET, VIBRATIDN-FREE HYDRAULIC PUMP AND CYLINDER COMBINATION CONTINUE PIER INSTALLATION UNTIL ROCK OR SUITABLE BEARINOSTRATA IS ENCOUNTERED BELONTiE UNSTABLE SOIL NEAR THE SURFACE y yFR[ Njy D RPLjt , SPACING rj�D RPI (Pe( CI SWLLL HOT EXCEED B FEET ON CENTER EXCEPT TO ACCOMOMTE WNIX V / DOOR OPENINGS AND AREAS OF RESTRICTION MAERELPON SPREADER BEAMS MALL BE USED UNDERPINS AT CORNERS HALL BE WTHIN 2 FEET OF THE CORNER OF THE STRUCTURE SPREADER SPREADERBFFSS MALL BE A MINIMUM OF ] FEET IN LENGTH AND LOCATED ON EITER SIDE OF W NDOW / DOOR OPENINGS AND WLL BE OF A SPECIRM SIZE AND LENGTH TO ACCOMMODATE WINDOW I DOOR OPENINGS GREATER THAN 8 FEET IN WOTH PRESSURE %ER FOUNDATION BRALNET NETBIID STANDARD BRAG 43.5 KIPS SPREADER BRMAET n (UPS SYSTEM DESIGN CAPACITY 3T KIPS TOP PLATE NOT-DIPZINC GAL 7 MILS ISATM AI23/ALZAII SPREADER BEAM A STEEL 'NMX13 BEAM, OR AN EGUVALENT BEAM WTH AN EQUAL OR GREATER SECTION MODULUS, WLL BE MECHANICALLY ATTACHED TO THE BRACKET FOOTING PREPARATION CONTINUOUS STRIP FOOTINGS B INCHES THICK OR LESS BALL BE SAIAH UT AND BUSHED AS NECESSARY TO ENSURE THAT THE ECCENTRICITY SETAEEN TIE MALL LOAD AND THE UNDERPIN BRACKET IS MINIMIZED. FOOTING THCIOESB GREATER THAN 81NCNES SHAH BE ANM,YZED BY THE ENGINEER TO DETERMINE ACCEPTABLE ECCENTRICITY. A CORROSION INHIBITOR WILL BE APPUED TO REBAR EXPOSED FROM CUTTING THE FOOTING WLL BE PREPARED TO ESTABLISH FILL CONTACT YATH THE BRACKET OR SPREADER BEAM. IF ADEQUATE FOOTINGS ARE IDENTIFIED THE ENGINEER MAY DESIGN A RETROFIT GRADE BEAM PRIOR TO COMPLETING THE UNDERPINS, THE UNDERPIN PIPE WILL BE SEALED TO PREVENT MOISTURE AND SOA FROM ENTERING. PIPE INSTALLATION THE ARGUE OF THE UNDERPINS SHOULD BE AS CLOSE TO VERTICAL AS POSSIBLE AND WLL NOT BE GRFATEfl THMN 5 DEGREES FROM VERTICAL MOJACENT UNDERPINS W LL NOT BE INSTALLED CONCURRENRY, UNDERPIN LIFT UFT MALL BE MONRORED TO REMAIN BELOW X. INCH. UNDERNNCOMPLETIOi UNDER%NPRESSLRESAND DEPTHSWILLBEREGORDEDANDPRONDEDTOTHEENGINEER THE AMOUNT OF BURRING UFT AT EACH UNDERPIN WLL BE RECORDED. DETASS CF ANY FOOTING PREP WORK WLL BE RECORDED UNDERPIN LOCATIONS WLL BE RECORDED. COBMETC REPMRS WLL NOT COMMENCE UNTIL A MINIMUM OF 34 DAYS AFTER CO PIZTIRI OF UNDERPINNING THE ESTIMATED PIN COMPLETION DEPTH WLL BE DETERMINED FOR EACH PIN DURING RNSTALAT SY THE MAXIMUM JACKING PRESSIRF OF ]WO P81 OR THE MAXIMUM UFT, WMICHIV ER IS ENCOUNTERED FIRST THE ENGINEER MAY SPEOFY A LOWER PRESSURE BASED ON THE CONDITION OF THE FOUNDATION AT SPECIFIC LOCATIONS TO AVOID DAMAGING THE STRUCTURE PRESS, %ER IMSTAl1ATON BYIIEM PIER TUBE 2.vr DO, 25551D._TM A580 DOA GRADE BC COLD'ORMED CARBON STEEL, Y LENGTHS MIN. YIELD STRESS+42 MMIN. TENBUE • SD KB SYSTEM CAPACITY 37 KIFS PRESSURE PIER INSTALLATION SYSTEM TACK SHEFFER, 3-IM' MORE, RATED 3.000 PM, (NOMINAL 24,900 M) PUMP SPX POWER TEAM ELECTRIC PUMP RATED I0,000 PB, 4- PRESSURE G Existing standard cast in place concrete monolithic footingi to be properly prepared, Intact, undamaged, and In full contnct with bracket or spreader beam Cas needed) M___16 �Mqq 4 1 SCALE (feet) IiiiiiiMMMD P1 P2 P3 PARTIAL EXTERIOR UNDERPINNING LAYOUT RECORDED OWNER; MOORE, MARY F PROPERTY ID: 31-19-31-517-0000-0060 ADDRESS: 2407 S SANFORD AVE SANFORD, FL 32771 LEGAL DESCRIPTIOW LOT 5 SOUTH PARK SANFORD PB3PG 62 LAND USE: SINGLE FAMILY RESIDENCE AREA(S): Base/Aux 1,248/354 YEAR BUILT: 1971 AERIAL LOCATION MAP A B1 = 5 240 A 3 A a A A 25 j 82 s 83 3 ^� - A Q1 • A P lay R A 84 I y Ir] A } $ 8519 PARCEL LOCATION MAP LEGEND: General Notes • ALL CONSTRUCTION SHALL COMPLY WITH 2O17 SIXTH EDITION BUILDING CODE AS WELL AS ALL STATE LAWS, LOCAL ORDINANCES, FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, THE STANDARD MECHANICAL CODE, THE STANDARD PLUMBING CODE, THE OCCUPATIONAL SAFETY AND HEALTH ACT, NFPA AND THE CURRENTLY ADAPTED STANDARD BUILDING CODE. • CONTRACTOR SHALL REMOVE ALL DEBRIS FROM THE PROJECT SITE AS REQUIRED TO MAINTAIN A SAFE AND ORDERLY WORK ENVIRONMENT. • GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO AND DURING CONSTRUCTION. • EXISTING GROUND SHALL BE PROTECTED DURING CONSTRUCTION. THE CONTRACTOR SHALL CLEAN AFTER CONSTRUCTION AND REPLACE AREAS DAMAGED AS A RESULT OF PERFORMANCE OF THE WORK. • THE CONTRACTOR SHALL SECURE ALL OPENINGS UNDER CONSTRUCTION AT THE END OF EACH WORKING DAY. • CONTRACTOR SHOULD HAVE GENERAL LIABILITY INSURANCE. • CONDITIONS SUCH AS INSUFFICIENT STEEL IN THE SLAB AND/OR OTHER STRUCTURAL CONDITIONS MAY BE DISCOVERED AFTER WORK COMMENCES THAT MAY NOT BE VISIBLE PRIOR TO COMMENCEMENT OF WORK OR EVEN DURING THE WORK. IF SUCH CONDITIONS ARE FOUND, CONTRACTOR WILL IMMEDIATELY HALT WORK AND INFORM THE OWNER AND/OR THE SITE ENGINEER. • IF, DURING THE COURSE OF FOUNDATION REPAIR, UNFORESEEN CONDITIONS ARE ENCOUNTERED THAT CREATE AN OBSTRUCTION FOR THE CONTRACTOR, THE CONTRACTOR WILL STOP THE WORK AND NOTIFY THE OWNER ANWOR THE SITE ENGINEER OF SUCH CONDITIONS. • CONTRACTOR WILL CHECK FOR DOMESTIC WATER LEAKS BEFORE AND AFTER THE FOUNDATION REPAIR PROGRAM. ANY PLUMBING LEAKS FOUND WILL BE IMMEDIATELY REPORTED TO THE OWNER AND/OR THE SITE ENGINEER. • CONTRACTOR WARRANTS THAT THE WORK AND MATERIALS WILL BE FREE FROM DEFECTS NOT INHERENT IN THE NATURE OF SUCH WORK AND MATERIALS. ALL WORK WILL BE PERFORMED AS STATED HEREIN. • CONTRACTOR NEEDS TO LOCATE ALL UTILITIES INCLUDING WATER, SEWER, ELECTRICAL, TELEPHONE AND IRRIGATION LINES AROUND THE PERIMETER OF THE BUILDING. • THIS LIMITED SUBSOIL STABILIZATION PROPOSAL tS BASED ON OUR CLIENT REQUEST AND THE PROJECT BUDGET. SINKHOLE GEOTECH, INC. WILL ACT AS A THIRD PARTY MONITOR ON BEHALF OF THE CLINT TO DOCUMENT, CONFIRM AND RECORD ALL FIELD DATA. WE CANNOT BE RESPONSIBLE FOR UNFORESEEN SOIL SHIFTS, MOVEMENTS, OR BUILDING CRACKING THAT MAY RESULT AS PART OF IMPLEMENTING THIS STABILIZATION PROCESS. SINKHOLE GEOTECH, INC SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES OCCUR DURING THE REPAIRiCONSTRUCTION WORK. IT IS OUR UNDERSTANDING THAT THE CONTRACTOR WARRANTS THAT THE WORK AND MATERIALS ARE FREE FROM DEFECTS AND IT IS UP TO FLORIDA BUILDING CODES AS DEFINED IN CHAPTER 18. • THIS LIMITED PROPOSED PLAN IS NOT INTENDED TO DEAL WITH ANY DEEP SOIL OR SINKHOLE CONDITIONS THAT MIGHT BE EXIST AT THE SITE NOR INTENDED TO BE A REPLACEMENT FOR A COMPACTION GROUTING PROGRAM. No. I Redsion/Inue I Dote P21 • INDICATES EXTERIOR UNDERPIN LOCATION AND NUMBER NOTES: 1. FLOOR PLAN LAYOUT IS APPROXIMATE 2. PIERS AND/OR OTHER INSTALLATION LOCATIONS ARE APPROXIMATE AND MAY REQUIRE ADJUSTMENT IN THE FIELD, AS APPROVED BY THE ENGINEER 3. STEP-UPS AND SPREADERS MAY BE USED IF NEEDED I hereby cer* that ibis plan and specification �w�p�by mgr6r undo' my�irect styaem� on / Ahmed Said., P.E. 70901 / /1NII II�M N /Ie� SiNmoLE GEOncm GE'OIBCIRUCAL s STRUCPURAI, CONSULTING 21M STATE ROAD Sl LUTL FLOMDA "M 171M PABCO ACRES DRIVE, SPRING HBL PItNUDA 3M810 EXTERM LNGERPDOGM PLAN ATI 1mt 1®RE lu50 HEATHVOOD AVE, SPRING HILL f�IM/OFeY•FMD TITAN FOUNDATIW REPAIR SPECIALIST 2407 S SANFORD AVE SANFUtD, FL IIM�1NE ei.w SGi.F1801-911]5 2-0-MIB ONE eMY AS SHOWN 03/28/2018 09:39 TITIAN (TAX)352 953 4151 P.0021002 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Nary, Longwood, Sanford, Seminole County, Winter Springs Date: -'�- ?,� 19 I hereby nw an agent of '4 to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The s ecific permit. and appl' tion for rk located at: n �.�..,__ I _ (street .address) Expiration Date for This Limited Power of Attorney:3- ,!;56 - 20 LK License Holder State License Number: Cfz-o'I � 5 ICE L (P Signature of License Holder: STATE OF );L� COUNTY OF p The foregoing ' Lqtru=nt was owledged before me this o� day of 1'Ci�-s 200, by r► 2— who is ❑ personally known to me or who has produced hU identification and who did 04Pnt1j take an oath. Si re (Notary Seal) Soon a f'�n i'� r.�►� 4i Print or type name Notary Public - State of Commission No. a/1 ,19 o S My Commission Expires: *6- 1 i? �r JONATHAN MCDONA[A (Rev. 08.12) � My COMMISSION *FFp1128p6 �+a'a,Yre EXPIRES April 16, g01a I�o� �osN�sa FladdaNataryagrylob.com 04/17/2018 13:11 TITIAN ff 4352 953 4151 P.0011011 F . IT 7AN FOUNDATION REPAIR SPECIALIST To:�17'tr Fax number:2— From: FOUNDATION REPAIR SPECIALIST,LLC Fax number: 352.593-4151 Date: .# :`f 7= (�)5 1 Regarding: ejosp- P-erm 1 18766 CORTEZ BLVD t3o* /r"" /O % v _ BROOKSVILLE FLMM.phone number fOr t — OFFICE: 352-593-4141 °°° 352-593-4141' o a o ]FAX: 352-593--4151 ai:�- up; Pages Including cover sheet: `l S FOUNDATION REPAIR SPECIALIST I.I.C. Offic U ER 35 93-4141 r r r J* S--)0)� 04/17/2018 13:11 TITIAN TAX)352 953 4151 P.0021011 SINKHOLE GEOTECH, INC. Geotechnical & Structural Consulting 21859 State Road 54, Lutz, Florida 33549 Report of Foundation Stabilization Short Street Investments LLC Property 2407 S Sanford Ave. Sanford, FL 34690-5910 Project No. SGT-F180z-91136 4/2/2018 04/17/2018 13:11 TITIAN (TAX)352 953 4151 P.0031011 E Jonathan McDonald & Rafael Rodriguez Presidents Titan Foundation Repair Specialist 18766 Cortez Blvd. Brooksville, FL 34601 Sinkhole Geotech, Inc. Geotechnical & Structural Consulting 21859 State Road 54, Lutz, Florida 33549 RE; Remediation Activities Summary Report At: Short Street Investments LLC Property 2407 S Sanford Ave. Sanford FL 34690-5910 Project No. SGT-171802-91136 Dear Mr. McDonald & Mr. Rodriguez, Per your request, Sinkhole Geotech, Inc. (SGT) is pleased to submit the Foundation Stabilization Report for monitoring partial underpinning pressure piers at the above referenced site. Per your request to provide underpinning pier plan to augment the foundation, SGT monitored the partial underpinning plan. The underpinning transfers the house load to more stable deeper soil and prevents further foundation movement. The purpose of this report is to provide certification that SGT, as a third party, monitored the partial foundation stabilization operation performed by Titan Foundation Repair Specialist on behalf of the client or homeowner at the above referenced structure. This report documents the pressure pier and the partial underpinning installation details of the work completed. The approximate locations of the perimeter underpin piers are depicted on the enclosed underpinning layout. WHAT IS UNDERPINNING? Underpinning is a process of augmenting the foundation underneath the building. There are a variety of methods to accomplish this, each with its own benefits and drawbacks. Generally, underpinning is a method of transferring the wall and roof loads on the foundations to deeper soils or even to the limestone itself. Short Street Investments Property SGT Project No.: SGT- F1802-91136 Page 1 of 3 04117/2018 13:11 TITIAN TAX)352 953 4151 P.0041011 HOW DOES UNDERPINNING WORK? Sinkhole Geotech, Inc. Geotechnical & Structural Consulting 21859 State Road S4, Lutz, Florida 33549 Underpinning Involves attaching steel piers using pin brackets to the foundation of the home, and driving those piers into deeper competent soils or to the limestone formation. If correctly planed out and mounted, underpinning supplies the lift the structure or foundation needs to meet a more satisfactory level, also providing a future support as a preventative from settling of the underpinned area. WHEN SHOULD UNDERPINNING BE USED? There is a variety of reasons when underpinning should be used. When buildings are on unpredictable land, there is often a possibility the foundation will become unstable. In this situation, underpinning may be necessary. Here are a few examples of situations that would require underpinning: • Structure is not even: re -leveling the structure • Cosmetic/structural cracks: closing of wide cracks caused by excessive settlement • Soils have changed or cavities were created; bypass weak soil layers • Soils have not been completely identified before construction began. pre - construction underpinning • The foundation may no longer be strong or stable enough for support of the structure: foundation augmentation • The structure's purpose may have changed: meeting the weight increase on the foundation • Structure needs additional foundation capacity to footings or mats with too little bearing capacity (building movement or ground consolidation is excessive) • Distressed or undermined Structure needs support; a catastrophic event (e.g. erosion, landslides, burst pipes, mine subsidence, etc.) • Adding load capacity to an existing foundation system to accommodate a seismic retrofit or addition of new structure, building stories, etc. • Cost considerations: homeowner preference to secure the foundation e At the Short Street Investments LLC Property, the underpin piers were hydraulically driven down to refusal or a maximum pressure into the underlying soils. The pier depths ranged from 16 feet to a maximum of 26 feet below foundation (see appendix B). The plan utilized 4 underpinning points as shown in the As -Built Plan, The jacking of each pier was terminated at a pressure that was appropriate to avoid damaging the structure based the condition of the foundation at each location. The piers were jacked to pressure up to approximately 3,000 psi, which provides more than 24,000 pounds of foundation support per pier. When the piers reached the ultimate support depth, each underpin bracket was sedured to the pressure pier with a 1/2" pin. The jacking depth Short Street Investments Property SGT Project No.: SGT- F1802-91136 Page 2 of 3 04/17/2018 13:12 TITIAN TAX)352 953 4151 P.0051011 Sinkhole Geotech, Inc. Geotechnical & Structural Consulting 21859 State Road 54, Lutz, Florida 33549 and pressures of each individual pier are presented in tabular form in the appendix of this report. In conclusion, to the best of our belief or knowledge, Titan Foundation Repair Specialist has completed this partial underpinning installation in accordance with applicable standard practice and the foundation has been stabilized and habitable at this time. Therefore, it is also our opinion that there Is no visual evidence of new or continued settlement activity at this corner location at this time. This documentation is limited to the partial underpinning installation only and not intended to deal with problem behind the limits of this partial underpinning repair. Our opinion is based on a reasonable professional probability from similar conditions and similar locations. In addition, it is not intended to remediate soil conditions that may or may not exist at the site such as buried debris, organic matter, or improper foundation design or embedment. No structural analysis has been performed to determine the structural integrity of covered structural members. SGT does not imply any warranty to the effectiveness of work performed nor should any be implied, but only accuracy of the information reported herein. We cannot be responsible for unforeseen soil shifts, movements, or building cracking that may result as part of implementing this stabilization process. �. This report and information contained herein was prepared for the specific and exclusive use of Titan Foundation Repair Specialist. Any other use of this report or parts of this report shall be authorized in writing by Sinkhole Geotech, Inc. The reproduction of any portion of this report in plans or other engineering documents supplied to parties other than the client or assigned parties must bear the language indicating that the information contained in the report is for general information only, and that neither the client nor SGT are liable to such parties. Respectfi]lll�Suhm.ltted, STlii;O,1NC. "Athted8 ltiv kl D r rltf pa�,l ls'gte eri�l. o n s u lta n t Apri12;-�, Short Street Investments Property SGT Project No.: SGT- F1802-91136 Page 3 of 3 04/1712018 13:12 TITIAN (TAX)352 953 4151 P.006101 1 a) As -built Plan b) Underpinning Logs c) Site Photos P2 P. LL LL-i IM- P3 P4 Lj* ,PARTTALIE)(TERJORUNDERPIUMNULAYQW 0411712018 13:12 TITIAN (FAX)352 953 4151 P.0081011 Short Street Investments Property PIER #1 PIER #2 PIER #3 PIER 44 PRESS, DEPTH PRESS, DEPTH PRESS. DEPTH PRESS. (psi) feet (psi) feet (psi)feet (psi) 100 3 100 3 100 3 100 100 6 200 6 200 6 200 100 9 800 9 2000 9 1500 V 500 12 2200 12 2200 12 1800 600 15 1000 15 2300 15 1800 1800 18 800 18 3000 18 2000 2200 21 2000 21 21 2400 2300 24 3000 24 24 2400 3000 27 27 27 30 30 30 30 33 33 33 33 36 36 36 1 36 39 39 39 39 42 1 42 42 42 45 4S 45 45 48 48 48 48 51 51 51 51 54 54 54 1 54 57 57 57 57 60 60 60 60 63 63 63 63 66 66 66 66 Lift 1/8" Lift 1/8" Lift 1/8" Lift 1/8" TOTAL DEPTH (Ft) 26 TOTAL DEPTH (Ft) 2 2/ TOTAL DEPTH (Ft) 16I TOTAL DEPTH (Ft) 24' Sinkhole Geotech, Inc. Project No.: SGT- F1802-91136 Page bl of bl 04117/2018 13:13 TITIAN (TAX)352 953 4151 P.009/011 Short Street Investments Property Sinkhole Geotech, Inc. Project No.: SGT- F1802-91136 Page c1 of c3 04/17/2018 13:13 TITIAN (FAX)352 953 4151 P.0101011 Short Street Investments Property Sinkhole Geotech, Inc. Project No.: SGT- F1802-91136 Page c2 of c3