Loading...
HomeMy WebLinkAbout2624 River Laing DrCITY OF SANFORD BUILDING & FIRE PREVENTION TF�D PERMIT APPLICATION Application No: coLA II Documented Construction Value: $ 2300.00 Job Address: 2624 River Laing Drive Historic District: Yes ❑ No Parcel ID: 26-19-30-5SY-0000-0800 Residential ® Commercial ❑ Type of Work: New ❑ Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: screen room with 3" Elite panel roof installed on existing slab Plan Review Contact Person: Annette Geissler Phone: 407 461-9926 Fax: 407 365-3194 Title: Secretary Email: sunstatesiding@aol.com Property Owner Information Name Norma M Simmons Phone: 40WOO-2'133i Street: 2624 River Landing Drive Resident of property? : yes City, State Zip: Sanford, FL 32771 Contractor Information Name Donald G. Geissler, Jr Sun State Siding, Inc Phone: 407 830-7778 Street: 510 Lake Lenelle Drive Fax: 407 365-3194 City, State Zip: Chuluota, FL 32766 State License No.: SCC048423 Architect/Engineer Information Name: Craig Gunderson Florida Engineering LLC Phone: 941 391-5980 Street: 4456 Tamiami Trail, B14 City, St, Zip: Port Charlotte, FL 33980-2101 Bonding Company: Address: Fax: 941 979-8195 E-mail: contact@flengineeringlic.com Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51 Edition (2014) Florida Building Code' Revised: June 30, 2015 Permit Application "' NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. t�� (signature of caner ' — Date WW6L W -Sc Wr -) OR wner/21g- n 's Name Sign tore Owner/Agent r n or Produced ID Type of ID QHC11) r ✓er b[ of No -State of Florida Date ;.•otPF�"�s��•.; JULIETTEM.ALVAREZ Notary Public - State Florida of Commission � FF 116887 ••�9j,FOFe��p�' My Comm. Expires Apr 28.2018 Permits Required Construction Type: Total Sq Ft of Bldg: yl� I 1"-I� Signature of Contractor/Agent Date TL o"a\d, � . �ac,5�r Print Contract or/A ent's Name 'Iwa 4 z-1z-LB +-, Notary tate of Flori =toMe r►'"W o1 Florida M138or a 0 Contractor/Agent is Personally Known to Me or - Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas❑ Roof ❑ Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads Job- . APPROVALS: ZONING: - - Sm TILITIES: ENGINEERING: COMMF"TTc- Flood Zone: # of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: Ok to install screen room with 3" elite panel roof on existing slab as shown on plan. The screen enclosure shall be constructed with same design, material and style as the others in the nearby and adjacent building. Revised: June 30, 2015 Permit Application R EQ UffRED ENSF ECTIO S1EQU ENC1E i SumBD]GmG PER.Mr Mnm M`al};c' Jj®� ee�u®n 11De�eII'u �u®m. Footer / Setback Stemwall Foundation / Form Board -.'Survey Slab /' Mono Slab. Pre our Lintel / Tie Beam / Fill / Down Cell Sheathing— Walls- Sheathing— Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Roof Final Stucco./ Siding Insulation Final Final Utility Building - Final Door Final Window - Final Screen.Room Final. Pool Screen Enclosure Mobile Home Building Final. Pre -Demo Final Demo. Final Single Family- Residence Final. Building. Other Mun Ma. Imp ecdon Description Electric. Underground Footer /' Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final �. '{I:�Artn�l.��t.,tt��/��':.iv L�����++ s2,aryuw:.. aq,yyL�+.RrY� .�vY,T1•Vl.' s �tyi�G-� C�7$I+�¢i h'C;G �ijzl"h!'r„ EA..a.. ,��'.f4j. ; Min max Inspection IIDescn*2flon Plumbing Underground Plumbing Sewer Plumbing Tub. Set Plumbing Final Mum Marc liras ection J(D•escrLion Mechanical Rough Mechanical. Final. Min Max rms ecgom.IIDescri ¢ion Gas Underground Gas Rough Gas Final REVISED: June 20144 SUN STATE SIDING, INC. PROPOSAL # 1 510 LAKE LENELLE DRIVE DATE 1 /04/2018 CHULUOTA, FL 32766 407 830-7778 phone 407 365-3194 faxState License SCC048423 Submitted to: Job Location: Marie Simmons SAME 2624 River Landing Drive Riverview Lot 80 Sanford, FL 32771 ree 31877Calg ma i I. c om We propose to furnish all the materials and perform all the labor necessary for the completion of: Furnish and install screen room on existing slab with 3" Elite panel roof $ 2,300.00 with 12" overhang, extruded drip edge fascia, 14' of 6" gutter and (1) 3 x 4 downspout, (1) 3' 0" x 6' 8" screen door, 18 x 14 charcoal screen, finish caulk. Chair rail height is 36" Site specific, engineer stamped plans & City of Sanford permit$ 300.00 All material is guaranteed to be as specified and the above work to be performed in accordance with the drawings and specifications submitted for the above work and completed in a substantial workmanlike manner for the sum of: $ 2,600.00 With payments to be made as follows: FULL PAYMENT UPON COMPLETION (we accept CASH or CHECK only) 0i Any alteration or deviation from the above specifications involving extra cost will be executed only upon written orders and will become an extra charge over and above the estimate. All agreements contingent upon strikes, accidents or delays beyond our control. Owner to carry fire, tornado, and other necessary insurance upon the above work. Workman's Compensation and Public Liability insurance on above work to be taken out by Sun State Siding, Inc. Submitted by DONALD G. GEISSLER, JR., PRESIDENT This proposal may be withdrawn by us if not accepted within 30 days. ACCEPTANCE OF PROPOSAL The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to perform the work specified. Payment will be made as outlined above. Homeowner_is.respopsible for any costs of engineer drawings and permits if contract is cancelled prior to work being performed. w� LCDate: Marie Simmons 8 Printed: Marie Simmons GENERAL NOTES 1. DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2017 FLORIDA BUILDING CODE, 6TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23 WOOD. 2. ASCE 7-10. & SE17 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. AC1318 CONCRETE REFRENCE MANUAL. 5. PCI PRECAST & PRESTRESSED CONCRETE. 6. AA ASM 35 & AA ADM 1 WIND LOADS: 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 130 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. SCREENED ROOF ENCLOSURE FBC 2017 CH. 20 TABLE 2002.4 CONCRETE & FOUNDATION DESIGN: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: A. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 -"ASTM C 150 11. AGGREGATES - LARGE AGGREGATE 3/4" MAX. - ASTM C 33 III. AIR ENTRAINING +/- 1 % - ASTM C 260 IV. WATER REDUCING AGENT - ASTM C 494 V. CLEAN POTABLE WATER VI. OTHER ADMIXTURES NOT PERMITTED B. METAL ACCESSORIES SHALL CONFORM TO: I. REINFORCING BARS - ASTM A615, GRADE 60 II. WELDED WIRE FABRIC - ASTM A185 C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. D. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. E. MOIST CURE OR POLYETHYLENE CURING PERMITTED. F. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. G. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION. 3. WHEN APPLICABLE FOR ATTACHING NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS. 4. WHEN INSTALLING 4" CONCRETE SLAB -ADD ADJACENT TO EXISTING-DOWELL INTO EXISTING CONCRETE 48" O/C W/8" #5 REBARS- DRILL 3/4'' HOLE 4" EMBEDMENT- EPDXY W/ NON -SHRINKING "SIMPSON EPDXY TIE" (OR EQUAL). 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHER WISE NOTED. ALUMINUM SPECIFICATIONS: ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE SPECIFIED. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. FASTNER SPECIFICATIONS: 1. FASTNERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG.) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, AND FASTENERS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4"X3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4"X2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14X2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10X1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE VX2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. MISCELLANEOUS: RECORD COPY REVIEWED FOR CODE COMPLIANCE PLANS EXAMINER 4,7-t DATE .� 0� ....... O� N u- =z:co o O =U ;v coo Q C)C). ' Z __ 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND INSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE SMB UNLESS OTHERWISE INDICATED RESPONSIBILITIES: 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. LEGEND: (ALL MAY NOT APPL SCR = SCREEN KP = KICK PLATE PW = PICTURE WINDOW X = HORIZ. SLIDING WINDOW 0 = HORIZ. STATIONARY WINDOW DH = DOUBLE HUNG WINDOW SH= SINGLE HUNG WINDOW SIP = SOLID INSULATED PANEL CT = CABLE TIE SG = SUPER GUTTER CS = CLEAR SPAN KB = KNEE BRACE ALUMINUM MEMBER HOLLOW SECTIONS 2 x 2: 2"x2"0.044" 2 x 3: 2"x3"x0.044" 2 x 4: 2"x4"x0.044" 2 x 5: 2"x5"0.050" OPEN BACK SECTIONS 1 x 2: 1 "x2"x0.044" 1 x 3: 1 "x3"x0.044" SNAP SECTIONS 2 x 2 SNAP: 2"x2"x0.050" 2 x 3 SNAP: 2"x3"x0.050" 2 x 4 SNAP: 2"x4"0.045" A PERMIT ISSUEC LICENSE TO PROCI AUTHORITY TO V ASIDE ANY OF THE CODES, NOR SHALI THE BUILDING REQUIRING A COI SELF MATING (SMB) 2 x 4 SMB: 2"x4"0.044"0.100" 2 x 5 SMB: 2"x5"x0.050"x0.100" 2 x 6 SMB: 2"x6"x0.050"x0.120" 2 x 7 SMB: 2"x7"0.057"0.120" 2 x 8 SMB: 2"x8"0.072"0.124" 2 x 9 SMB: 2"x9"0.082"0.124" 2 x 10 SMB: 2"x10"x0.092"0.398" NOTE: AS INDICATED ABOVE ALL MEMBER PROFILES ARE INDICATED IN INCHES. SHALL BE CONSTRUED TO BI :ED WITH THE WORK AND NO' OLATE, CANCEL, ALTER OR S' PROVISIONS OF THE TECHNII ISSUANCE OF A PERMIT PRE OFFICIAL FROM THEREAFTER SECTION OF ERRORS IN PLAT OR VIOLATIONS OF THIS COE 18-1647 3" X. 024 X 1 LB FL 7561.1-R4 1X2 `^z N NON Nn1 00 x x_x xx�,_ �N co , 0o 2X2 2X2 °O 0 1X2 1X2 "' 2'-0" 51-0" \ EXISTING COVERED LANAI X, " X .024 X 1 LB COMPOSITE ROOF PANEL$ O O (FL. PRODUCT APPROVAL # 7561.1-R4) ------------------------------------ 6" SUPER GUTTER 14'-0" \EXISTING SHINGLE ROOF\ 2X3 I 2X3 N N 2X2 I 2X2 1X2 1 1X2 6'-2" 6'-2" 12'-4" O 3" X .024 X 1 LB FL 7561.1-R4 /p" 1 X2 2X2 00 N N N N x x= x x 00 Ln N 00 2X2 2X2 00 0 `o 1X2 1X2 �-5-0"� \4'-2"\ EXISTING SHINGLE ROOF i o co uj. a :Z CD w ::� 0 CQ > Z co C3 O ,, d,� •......PRoF ,� w ROOF PER PLAN HOST m COLPER CHAIR RAIL PER F Lu rn 0 x 1/4'X2-1/4" TAPCONS @ 24" O.C. 2"X2" PER PLAN ATTACH To ROOF PANELS W/# 12 X 2-1/2" SMS 12" O/C ALTERNATES FOR C TO 2"X2"AT HEADER 1- DETAIL C 2- (4) # 10 X 3" SMS THROUGH MEMBER INTO COL SCREW Bi 3- NOTCH COL TO R BEAM FASTEN Wl (2) W THRU-BOLT 1 " X 2" FASTEN TO ADJOINING WALL W #12 X 1-1/2" SMS 181, O/C ------ EXISTING CONCRETE TYPICAL SIDE WALL DETAIL: SCREEN ROOM END WALL SCALE:NTS -1 SELF -MATING OR 1/8"x2"x2"x ANGLE SNAP SECTION TYP. 5032 H-32 ANGLE 2 - #12 SMS INTO COLUMN 1"x2" O.B. BASE PLATE-TYP. 1/4" MASONRY ANCHOR EACH o ol ANGLE - EACH SIDE COL. o 0 2-Y4" MIN. CONC. ANCHOR EMBEDMENT MIN 4" SLAB 3000 PSI . ...... ....... 2" MIN, INCREASE DISTANCE CONC. w/FIBERMESH WHEN GREATER THAN 2x4 UPRIGHT IS USED ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL w/(4) #10x.75" INTO GIRT OR PURLIN & (2) #14x.75" (4) #10 x 1-1/2" SMS INTO INTO BEAM OR UPRIGHT 0.062 ANGLE T1 CLIPS MAYBE USED CONC. FOOTING BELOW-----� SCREW BOSSES SIDE VIEW NOTE: WHERE PAVERS ARE PRESENT USE 5/16" TAPCON XL (RED HEAD MFG.) MASONRY ANCHORS TO PENETRATE UNDERLYING CONCRETE FOOTING 2-1/4" (MIN.) 1/4" MASONRY ANCHOR PURLIN, GIRT, AT EACH ANGLE 2 - #12 SMS HEADER OR SILL —4 1 UPRIGHT, BEAM -SNAP, i'1_1/4" TAPCON XL (RED HEAD MFG. OR EQUAL) SELF MATING, OR HOLLOW 2 @ lx2 BASE 2 @ SLAB (BEYOND) i Lv�_l i T 2SIF .... .... . ............ 1"x2" BASE PLATE ANCHORED .......... ....... TO CONC vil 1/4" MASONRY BEAM ....... ANCHOR 6" MAX EACH SIDE DETAIL "C" -GIRT OR PURLIN TO TAND 24" O.C. MAX OR POST OF POS 0 0 DETAIL R ST �DETAIIL SCALE: ......... CONC. FOOTING BELOW------ FRONT VIEW NOTE FOR 2x3 UPRIGHT TO DECK USE DETAIL "B" �-2"xC4" OR LARGER SELF MATING (1) 1/4" MASONRY ANCHOR @ BASE PLATE E/S '0 LARGER S _ T T TO DECK 9 p TT Fu' PRIGH DE K DETAILS SCALE:NTS ADJOINING BEARING WALL c"I .......... G 0 0 0) CD IL 00 LU (.0 LIJ 0 0 Z W 0 w 0 FOR ALUMINUM PANS #12 X 2" SMS THROUGH "BOXED END" INTO WD FASCIA (3) PER PAN FOR COMPOSITE PANELS #12 X3/4" SMS 12" O/C #1? x 2" SMS 12" O/C *(internal) .0 3" BEAM PER 'U-head&' COL. PER PI AN WHERE MIDPOINI COL IS INDICATE[ CHAIR RAIL PER PLAJ, FASTEN PER DETA_ WHERE PAVERS ARE PRESENT INSURE PENETRATION INTO UNDERLYING CONC. OF 1 1/2" MI WHERE KICK PLATE IS INDICATED --- FASTEN Wt #10 X 9/16" SMS 8" O/C AT PERIMETER I FOR PANS #12 X 9/16" SMS Wt 5/8" NEO-WASHER-(3) PER PAN FOR COMPOSITE PANELS (#12 x PANEL THICKNESS SMS PLUS 1" LG.) Wt 1-1/2" NEO- WASHER @ 12" O/C COVER END PANEL �,__ (2) 1/4" THRU-BOLT DETAIL: SCREEN ROOM FRONT WALL SCALE:NTS ALTERNATES FOR DECK ATTACHMENT SMB -PER DETAIL B 1/8" X 3" RECEIVING CHANNEL (2) 1/4" X 2" QUICKSET INTO CONC. (2) #14 X 9/16" E/S COL. 1/8" X 2 X 2 X COL SIZE ANGLE 2) 114" X 2" QUICKSET INTO CONC. 2) #14 X 9/16" E/S COL. FOR WOOD DECK ALL FASTENERS TO DECK 1/4" X 2 1/2" GALV. LAG BOLT 64880eWes Inc. Land Surveyors 769 Douglas Avenue, Altamonte Springs, Florida. 32714 (407)788-8808 Member of the Florida Surveying and Mapping Society and American Congress on Surveying and Mapping Areas Lad Leadw.& V-7 75 +23 Sq. FL 320 Sq. FL 75 7esq. FL 341 sq. FL rl 1BSm. 341 S¢ Fr. 79 ZSsq. FL W! Sq. FL 79 HSq. FL 341 Sq. FL 80 r23 Sq. FL 320 Sq. R Map of Survey _ Tract C" Drainage & Retention O LLot L—V o ietv -&�mtownh0 e49.33'D .� 136.o0'Wt?Fuxhad F E7av: 24 '�Lot 74 e for 7s Lor 77 cor 7a Lor 79 ! Lot Bo ..,JLot 81 uroeo7f 14 rta� ~ z �rr.r~ V350;' tsvr 4. S 54 2231"E 165.01 3.50 357.73 54 _ _ _ _ _�-- e acp — )Met Et2120 N W22'31" W 71223 t� CIL River Landing Drive (34' WW) Tract '8"AccessI� LEGAL DESCRIPTION Lots 75, 76, 77, 78, 79, 80, Riverview Townhomes Phase lI" I _ �[ I VCy� accordy to the plat thereof as recorded in plat bdok 75 atpage(s) 51- 58 �(-"-_' - - - - -• of the public records or Seminole county. Florida (,-. �; . . FLOOD HAZARD DATA: The panaal shown hereon lies widdR Flood Zmre X' sErnef'vc. according to the Flood lnsumrn Rate Map community panel number Ok to install screen room with 3" elite pane 1202940060Fdated 92af2007. Plead Z odete—nali--padoormadbyg-pt—ptotanghornFlood roof on existing slab asshown on plan. The insurance Rate Maps provided by FEMA No held surveying ivas performed this firm to determine this zone. The exact = a, location can only be determ screen enclosure shall be constructed with - byan sfavalion study. We assume no responstbAW foraclualllooding same design, material and style as the others to General Notes.- 1. This is a BOUNDARY Survey performed in the held on o f the nearby and adjacent building. - Z No astral, surface or subsurface ubTify installations, underground improve�SErs subsurfacoa@ralencroachments Bany, were located. Sow 14ackalsdawatk 3. Building ties shown are to the exterior unfinished foundation surface or forrlbdald. so L� F'C Flint olCurvNum 4. Elevadons shown hereon, irany, are assumed and were obtained from approved C«vrrprfDes Anob PCC. FbW of campemd Cuvalum P P' °a c°"°u P°`°r Conshucdon plans provided by the Client unless omerwise noted, and are shown CALC ��d PsgPene . Page onlyto depict the pmposed ore dMerene9 m elevation relative to the assumed Ce Chmd aeanng P krvxr MgnumeN - P.RM. Pmpe temporary Benchmark shovm hereon. 5. The parcel shown hereon is sub%M tD a9 easements, m3emlions, restrictions, cc cl-y Line Fvt Property tine and C.M. Concrete Lfonu~t P.D.B. IY:Mof Beg)noing Rightsvf--way of -card whether depicted or not on this docuntenf. No search of the FLarEL Gnmter./Proposed) P.o.a F—afCammencament FINAL D- t+ue°s"`�1 PR Ports oftntm Public Records has been made by this office. � Cu FhWarT.Me.:�� 6. The legal descnption shown hereon is as fumishad by dent Rn.Al Elev. FrnishedF-bor6sveton PT. 7. Platted and measured distances and directions are the same unless otherwise noted. I.P. Iron F.pe Pr. Radii ar re perry R Radius only. 8. Copies of this Survey may be made for the original transaction on e Denotes %* iron rod with plastic cap marked LB4937, or W iron rod with 1 R. eon Rod R/tD Radial ti- L Am Length RES. Rksidence red plastic cap marked Witness Comer, unless otherwise noted. La Lxenwd af5iest; RAv R9NdbWay Land Sxveror TWa Temporary Benolmara O Denotes P.C.P. (Permanent control point) usea Measure•! TYP. Types ® Denotes Permanent Reference Monument rvrD(NdOI Nsl and Disk �� Fence symxl (see drawing) ® 2013 Herx & Assoctates Iria All rights reserved N.R. NN Racal x F£npe symbW isso drawing) Cutaleadon: not raid wmout Ne - mddle anOblal nlsrdsoa/ Drawn by: CM ofa Aorfds lieonsadSorvryormd r Checked by. DLP ymeets the +agWre MinimumT Prepared for. Homes in =C, Adatnmrakm _ Sketch of Legal Description 07- mob Number. 074D5 OZ - This is NOT a surveyscale: Plot Pram Perrermed: 03-04-13 n Performed. WW—A. Harx, P.Ls. Florida R09is:em 3 $$$mveiotNO. 31 Fonmboard Survey. Danes f-Pr +rvatiac.4 P.s". RepiYerwJ �yOra,,o copper No. saw Final Survey: Hens a Assoaues Im. State of F o ids tB a „f Revfsfoms: TOTAL P.01 'Florida Building Code Online https://floridabuilding.org/pr/pi app_dti.aspx?param=wGEVXQwtDq. ;: FA BCIS Home Log In User Registration Hot Topics Submit Surcharge r Stats & Facts Publications FBC Staff j SCIS Site Map $ Links i Search bHoridp Product Approval r? USER: Public User Product Approval Menu > Product or Aoolication Search > Application list > Apprkation Detatf FL # FL7561-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Elite Aluminum Corporation Address/Phone/Email 4650 Lyons Technology Parkway Coconut Creek, FL 33073 (954) 949-3200 dk@dokimengineering.net Authorized Signature Do Kim dk@dokimengineering.net Technical Representative Bruce Peacock Address/Phone/Email 4650 Lyons Technology Parkway Coconut Creek, FL 33073 (954) 949-3200 bpeacock@elitealuminum.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Products Introduced as a Result of New Technology Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer - Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Do Kim, P.E. the Evaluation Report Florida License PE-49497 Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/30/2022 Validated By CBUCK Engineering Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL7561 R4 COI Cert of Indeoendence.odf 1709.2 1 of 2 2/25/2018, 1:12 P1V Florida building Code Online https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDq.. Product Approval Method Method 2 Option B Date Submitted 08/15/2017 Date Validated 08/16/2017 Date Pending FBC Approval 08/20/2017 Date Approved 10/10/2017 Summary of Products Model, Number or Name + Description 7561.1 Aluminum/Aluminum Composite j 3"/4"/6"x0.024"xllb EPS Composite Panel, Panels i 3"/4"/6"x0.032xIlb EPS Composite Panel, 37476"x0.024"x2lb EPS Composite Panel, ft� ! 3"/4"/6"x0.030"x2ib EPS Composite Panel, ` Limits of Use 1 Installation Instructions Approved for use in HVHZ. Yes ! FL7561 R4 II 2017 FBC-Elite Aluminum Coro -Install Approved for use outside HVHZ: Yes Instruct.pdf Impact Resistant: No Verified By: Do Kim, P.E. PE 49497 { I Design Pressure: +801-80 Created by Independent Third Party: Yes Other: In HVHZ, not to be used in structures considered Evaluation Reports living areas per FBC Section 1616 unless impact protection is FL7561 R4 AE FL 7561 Evaluation Report-2017 FBC pdf provided. See installation drawing for nominal allowable Created by Independent Third Party: Yes design pressures and spans. Bade Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 phone: 850-487-1824 The State of Florida is an AAIEEO empbyer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: A ceecibiilty Statement:: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mad address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have arty questions, please contact 850.487.1395. *Pursuant to Section 4S5.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaits provided maybe used for official communication with the licensee. However email addresses are public record. V you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you area licensee under Chapter 455, F.S., please click ham. Product -Approval Accepts: W® t.CFFCY. Credit 2 of 2 2/25/2018, 1:12 PM ®O KIM & ASSDCIATES9, LLC CONSULTING STRUCTURAL ENGINEERS Florida .Board of Engineers Certificate of Authorization No. 26887 Product Evaluation Deport Date: August 10, 2017 Report No.: FL# 7561-R4 Product Category: Roofing Product sub -category: Products introduced as a Result of New Technology Product Name: EPS Foam Core w/ Aluminum Skin Composite .Panels Manufacturer: Elite Aluminum Corporation 4650 Lyons Technology Park -way Coconut Creek, FL 33073 Phone: 800-421-0682 Scope: This product evaluation report issued by Do Kim and Associates, LLC and Do Kim, P.E. for Elite Aluminum Corporation is based on Florida Department of Business and Professional Regulation Rule 61 G20-3.005 (2) Method 2 (b) of the State of Florida Product .Approval .Re-evaluation of this product shall be required following pertinent Florida Building Code modifications or updates. Do Kim and Associates, LLC and Do Kim, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Florida .Building Code, 6`h Edition (FBC) and where pressure and deflection requirements, as determined by Chapter 16 of the Florida Building Code, do not exceed the design pressures as shown on the approval. Q0 '10EN''�/ Na. �31B] (CS FLORIDP..`��`; 3H.a—n.,b> dR lcg gMd�Wby.00v. oniAL 10sd Wsd.leudngod—d5g-dv dPamed Wdi na:ao�ml.���da>.ady�.�a.�a..em. yy1.LBAm�nmm.�yd�,w�.�cn. NJ17118.15113133133 -04'1' W Do Kim, P.E. FL #49497 P.O. Box 10039 813.857-9955 Tampa, FL 33679 dk@dokimengineering.net Sheet 1 of 3 DO KIM & AssociATES, LLC CONSULTING STRUCTURAL ENGINEERS Supportin6 Documents 1. Code Compliance a. The product assembly described herein has demonstrated compliance with the Florida Building Code 61h Edition (FBC), Section 1709.2. 2. Drawings: a. Drawing No. FL-1001 titled `'EPS Foam Core Composite Panels", Sheets 1 and 2 prepared by Do Kim and Associates, LLC., signed and sealed by Do Kim, P.E. 3. Testing a. Testing per ASTM E72-05 as perfonned by Hurricane Engineering & Testing, Inc. (HETI), and reported in test report numbers HETI-05-1988, HETI-06-2104, HETI-06- 2066, HETI-06-2105, HETI-06-2067, HETI-05-1.002, HETI-06-2107, HETI-05-1987, HETI-06-2069, HETI-06-2070, HETI-06-2071, HETI-05-1994, HETI-05-1991, H:ETI- 06-2072, HETI-06-2073, HETI-06-2074, HETI-05-1996, HETI-05-1989, HETI-05-1993, HETI-05-1985, HETI-05-1995, HETI-05-1.990, HETI-05-1997, HETI-05-2037, HETI- 05-2029, HETI-05-2039, HETI-05-2030, HETI-05-2041, HETI-05-2048, HETI-05-2036, HETI-05-2031, HETI-05-2038, HETI-05-2065, HETI-05-2040, HETT-05-2042. 4. Calculations a. Panel performance engineering analysis for tested loading conditions have been prepared based on comparative and/or rational analysis, prepared, and submitted by Do Kiln, P.E. 5. Other a. Quality Assurance Agreement verified with Quality Auditing -Institute, LTD. (QAI Laboratories, LTD.) (FBC Organization #QUA7628). P.O. Box 10039 813.857-9955 Tampa, FL 33679 dk@dokimengineering.net Sheet 2 of 3 ®O Kim & ASSOCIATES9 LLC CONSULTING STRUCTURAL ENGINEERS Limitations and Condition of Use 1. Code Compliance a. The product assembly described herein has demonstrated compliance with the Florida .Building Code 6"' Edition (FBC), Section 1709.2. 2. Large and small missile impact resistance has NOT been tested to or evaluated for in this approval. In HVHZ, this product shall be used in structures "not to be considered living areas" per Section 1616 unless impact resistance in accordance to the H.VHZ requirements are met. 3. Each product listed above shall be installed in strict compliance with its respective Product Evaluation Document and site -specific engineering along with all components noted herein. 4. Use of each product shall be in strict accordance with its Product Approval Evaluation and Limitations of Use. 5. Composite panels shall be constructed using type 3003-H154 aluminum facings, 1 or 2 :PCF ASTM C-578 Dyplast Products LLC brand EPS foam insulation (NOA No. 16-1129.05) adhere to aluminum facings with Ashland Chemical 2020D ISO grip. Fabrication to be by Elite panel products only in accordance with approved fabrication methods. 6. Elite roof panels maintain a UL 1715 (int) class `B' (ext) rating and are NER-501 approved. 7. This specification has been designed and shall be fabricated in accordance with the requirements of the FBC, composite panels comply with Chapter 7 Section 720, Chapter 8 Section 803, Class A interior finish, and Chapter 26 Section 2603. All local building code amendments shall be adhered to as required. 8. The designer shall determine by accepted engineering practice the allowable loads for site specific load conditions (including load combinations) using the data from the allowable loads tables and spans in this approval. 9. Deflection limits and allowable spans have been listed to meet FBC including the HVHZ (L/80 for spans < 12'-0" and L/180 for spans > 12'-0"). 10. All supporting host structures shall be designed to resist all superimposed loads. 11. All components which are permanently installed shall be protected against corrosion, contamination, and other such damage. 12. Size and Span .Limitations: a. Composite panels shall be limited to those specific panels listed in the DWG. FL-1001. b. Panel spans shall not exceed those listed in the tables of DWG. FL-1001. P.O. Box 10039 813,857-9955 Tampa, FL 33679 dk@dokimengineering.net Sheet 3 of 3 ELITE PANEL SPAN TABLES 3" x 0.024 x I - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD <PSF)I. MAX. ALLOWABLE SPAN (FT> L/80 L/120 L/180 L/240 10 16,17 l5.76 15.03 14.10 20 13,44 I3.44 12.22 10.35 30 10.78 10.7E 9.41 6.60 40 9.22 9.22 6,60 2.85 $0 0.17 8,17 3,79 60 7A0 6.39 0,98 70 6.BI 4.51 80 1 633- 4" x 0.024 x I - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 19.00 19.00 17.17 16,53 20 15.01 I5.01 15.0! 13.95 30 12.90 I2.50 12.50 11.38 40 10.97 10.97 10.97 8.80 50 9,92 9.92 9,aa 6.22 6D 9.IJ 9.t3 7.51 3.64 70 8.5; 852 5.58 1.07 BO 8,02 8,02 3.64 - 6' x 0,024 x I - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX, ALLOWABLE SPAN <FT) L/80 L/120 L/180 L/240 IO 23.00 2L 4 21.47 20.85 20 18, 06 18.06 I B.06 18.06 30 IS,i3 15.13 I5.13 15.13 40 13.3a 13.34 13.34 13.34 50 12.10 12.10 12,10 10.91 60 11.17 n.17 11.17 8.43 10 10A4 10.44 10.30 5.95 80 9.85 9,8$ 8.43 3,47 1. Net allowable loads are permitted to be multiplied by 1.67 to derive ultimate loads (psf). 3' x 0.032 x I - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)I MAX, ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 77.S0 I7.50 1691 15.96 20 16,64 15.96 14.06 12.16 30 15.17 14.06 11.21 36 8M76 40 13.69 12.16 8.36 50 12.22 10.26 5.51 60 10.75 836 2.66 70 9.27 6.46 80 7.80 4.56 4' x 0.032 x I - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD <PSF)I MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/I11 L/240 10 20.50 20.50 20,11 19.24 20 19.61 l9.24 17,49 15,74 30 18.17 l7, q 9 14.87 1224 40 16.72 15,74 12.24 8.74 SO 15.28 13.99 9,62 5.25 60 13.84 12.24 7.U0 1.75 70 12g0 10,49 4.38 BO ]0.95 8,74 1.75 6' x 0,032 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX, ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 t0 24.00 24.00 24,00 23.42 20 23.34 23.21 21.82 2022 30 22.10 21.63 19.42 17.0 40 20.86 20.05 17.02 13.82 50 19.62 18.47 14.62 10,62 60 1H.38 16.89 12.22 7.42 70 17,1q IS.JO 9.02 4.22 BO 15.91 1 13.72 7.42 1.02 3' x 0,024 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS> NET ALLOWABLE LOAD (PSF)1 MAX, ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 19.33 18.95 18.3I t7.66 20 18,11 7 7.66 16.36 15.06 30 I6.80 16.36 14.41 12A6 40 15.49 15.06 12.46 9.06 50 14.18 i3.76 10.31 7.26 60 12,87 1246 8.57 q.67 70 11.57 11.16 6.62 2.07 80 1026 9.86 4.67 4' x 0.024 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)I MAX, ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 2197 2L97 21.52 20.97 20 20.77 20.77 19.86 16.76 30 19.57 19.$7 lB.21 16.53 40 18.36 I B.36 16.55 14.34 50 17.16 I],IG 14.09 12.13 60 15.96 15.96 13.24 9.93 70 14.75 14.75 11.58 7,72 80 1J,55 13.55 9.93 5.51 6" x 0,024 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)I MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 23.93 23.93 23,Be 2360 20 23.20 23.20 23.03 22.46 30 22.47 22.47 22.18 21.33 40 21.75 21.75 21.33 20.20 50 21.02 21.02 20.49 19.07 60 20.29 20�29 t9.64 17.94 70 19.57 19.57 I8.79 16.81 80 1 u,t 10.84 17.94 1$.68 GENERAL NOTES 1. Composite panels shall be constructed using type 3003-11154 aluminum facings, I or 2 PCF ASTM C-578 carpenter brand EPS adhere to aluminum facings with Ashland Chemical 20201) ISO grip. Fabrication to be by Elite panel products only in accordance with approved fabrication methods. 2. Elite roorpanels maintain a UL 1715 tint) class'B' (exl) rating and arc NER-501 approved. -. This specification has been designed and shall be fabricated in accordance with the requirements of the Florida Building Code 6'h Edition (FBC), composite panels comply with Chapter 7 Section 720. Chapter B Section 903, Class A interior finish, and Chapter 26 Section 2603.. All local building code amendments shall be adhered to as required. 4. The designer shall determine by accepted engineering practice the allowable loads liar site specific load conditions (including load combinations) using the data IPont the allowable loads tables and spans in this approval. 5. Deflection limits and allowable spans have been listed to meet FBC including the HVIiZ:In lIV[ IZ, this product shall be used in strue(urcs "not to be considered living areas" per Section 1616 unless impact resistance in accordance to the I IVIiZ requirements are met. 6. Safety factor of 2.0 has been used to develop allowable loads and spats front testing in accordance to the Cuidelines Ibr Aluminum Structures Pan I and conforms to [lie FI3C Chapter 16 and 20. 7. 'Testing has been conducted in accordance to ASTM E72-05: Strength Test of Panels for Building Construction. 8.. licl'ercncc test reports: FIETI-05-1988, IIETI-06-2104, 11FTI-06-2066, FIETI-06-2105, FIEfL06.2067, HE 1-1.05-1002, 06-2107. 11E'r1-65-1957, HEPI.06-2069, llErl-06-2070,.11E-1'I-06.207I, FIET1-05-094, I1ETI.05-1991. FlETI-06-2072, I-IETI-06.207.3, FIETI-0&2074. I-IETI-05-1996, FIETI-03-I989, I-IETI-05.1993, IIETI-05-1985, I IETI-05-1995. IF)ETI-05- 1990. IIETI-05.1997, 1-IIiTl-05.2037, FII r1-05-2029, 11111-05-2039, lil'I'i-05-2030, lit'TI-05.2041. FIE1-I-05.2048, HL'fl- 05.2036. 111 11-05-203I, HEIl-05-2035. ME I'I-05-2065, IF'I'i-05.2040. 1-111TI-05-2042. 9. Linear interpolation shall be allowed f-or figures within (he tables shown, 10. Panels with lim beans shall be considered equivalent to similar panels without tun beams. Design professionals may include 3' x 0.030 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/L80 L/240 10 20.11 20.03 19A2 IB.81 20 19,02 18,81 17.5E 16.35 30 I1.93 17.58 15.73 1 13.89 40 16,8 3 16.35 13.89 1 1.43 50 15.74 15,12 9 12.05 8.97 60 14,64 13.89 10.21 6.52 70 73.55 12.66 8.36 4.06 80 12.46 11.43 6,52 1,60 4' x 0,030 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)I MAX, ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 ID 24,17 e4,17 24.17 24.17 20 23.64 23,64 23,41 23.11 30 22.57 2257 21.90 2141 40 21.51 21.51 20.39 18.97 SO 20A5 20.a5 18.88 i6.B0 60 19.39 19.39 17.37 14.70 70 18.33 1833 15.66 12.59 80 17R6 17.26 14,35 10.99 6' x 0,030 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD ([`St )i MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 t0 24.00 P4.00 24A0 23.8a 20 23.65 23.63 23.34 22.84 30 22.94 22.9a 2259 21.BS 40 22.23 2223 21.85 20.85 50 21.53 2L53 21.10 19.86 60 20.82 20,82 ?-0.36 10.8] 70 20.11 20, 11 19,61 17,87 80 19A0 19.40 18.87 16.80 _ SEAL JOINT WITH CONTINUOUS CAULKING )U U0 U(-T UUUU OUOUOn za )0000000000i aH OTTOM FA I S INTERLOCKING CRn" SECTION OPTIONAL GUTTER OR w DRIP CAP SLOPE 4' MAX WIDTH INTERLOCKING 000 PANEL (I14.7FT MIN SLOPE) V 000000000000 ? EPS CORE ILB OR 2LB 00 o0O00 as 000 000 00 a ALUMINUM BOTTOM 00 i I FACINGS O0C CLEAR SPAN (U INSIDE. TO INSI➢E 00 O.H.-- 0 000 ENGINEER OF RECORD TO PROVIDE 0 FOR ROOF CONNECTIONS & A00 THICKNESS OF 00 36' MAX IN FRONT 2.25X c SUPPORTING STRUCTURE DETAIL BY WALL FOR TOTAL 000 OF PANEL WIDTH B SIDES a THIS OR ANY OTHER ENGINEER, - PANEL SPAN, 000 (12' MAX AT SIDES) c EPS ROOF PANEL/ SPAN DESCRIPTION D❑ KIM 6 ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tamp,, FL 33679 TO (813) 057-9955 Q J p N Z d' a O Y M W DO CL N (v pr PMU EL M rn 5 a rn _j DL 0 0 o LL M of U to 0 CL E t U a w Ui � V p LU 0 C U Z F a J 0 a j( J 1110 L) Oa0¢ t° (L UU O J LL I -TA p Y.' I k' O.WYGENSF .�/ Y FLA. AEC. NU1.IBER 49487* �'. DO KIIA 8 ASSOCIATES. LIB ��CC/(��fJ�, 2266BB7 'PIS�b�110039; SS F�e7R pDB?6�� Drawing No. - FL-1001 SHEET 1 OF 1