HomeMy WebLinkAbout468 Rosalia Dr (2).-7
CITY OF'
SkNFORDBuilding & Fire Prevention Division
FEB Z 1�11� PERMIT APPLICATION
Application No:
.Documented Construction Value: $ 1200.00
Job Address: 468 Rosalia Drive Historic District: Yes❑No7
Parcel ID: 31-19-31-508-1300-0170 Residential Commercial❑
Type of Work: New[] Addition ✓❑ Alteration[] Repair❑ Demo❑ Change of Use Move❑
Description of Work: Reside gable ends and garage wall. &% f,�C
Plan Review Contact Person:
Phone: 321 377 6105
David Title: Owner
Fax: N/A
Email: dpazdur@msn.com
Property Owner Information
Name David J. Pazdur Construction LLC Phone: 321 377 6105
Street: 2301 Cameron Ave.
City, State Zip: Sanford, FI. 32771
Resident of property? :
Contractor Information
Name David J. Pazdur Construction LLC Phone: 321 377 6105
Street: 2301 Cameron Ave.
City, State Zip: Sanford, Fl. 32771
Name: N/A
Street:
City, St, Zip:
Bonding Company: N/A
Address:
No
Fax: N/A
State License No.: CRC038083
Architect/Engineer Information
Phone:
Fax:
E-mail:
Mortgage Lender: N/A
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6th Edition (2017) Florida Building Code
Revised: January I, 2018 Permit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
�16 /
Signature of Owner/Agent Date Signatur of Co ractor/Agent D to
Print Owner/Agent's Name
Signature of Notary -State of Florida Date
Owner/Agent is Personally Known to Me or
Produced ID Type of ID
Name
J,,non,1,acto,/Agcnt's
Z_ Z(p- 1
Signature of Nota
"' "'•.
ANNETTE N1 BLAND
Notary Public - State of Florida
Commissior tt GG 17090C
My Corrrr. Expires Jar 16, 2022
5crcec:hrc_crtia�cra NoarvAssn.
Contractor/Agent is Personally Known to Me or
Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas❑ Roof ❑
Construction Type:
Total Sq Ft of Bldg:
Occupancy Use:
Min. Occupancy Load:
New Construction: Electric - # of Amps
Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads
APPROVALS: ZONING:
ENGINEERING:
COMMENTS:
UTILITIES:
FIRE:
Flood Zone:
# of Stories:
Plumbing - # of Fixtures,
Fire Alarm Permit: Yes ❑ No ❑
WASTE WATER:
BUILDING: 5F 4.1. 1
Revised: January I, 2018 Permit Application
This Instrument Prepared by and Return to:
John Taylor
Fassett, Anthony & Taylor, P.A.
1325 W. Colonial Dr.
Orlando, FL 32804
Our File No.: 4529-170 (Toni Sweeney)
Property Appraisers Parcel Identification (Folio) Numbers:
31-19-31-508-1300-0170
SPACE ABOVE THIS LINE FOR RECORDING DATA
THIS WARRANTY DEED, made the 31 st day of January, 2018 by James C. Kneeland, III and Marilyn M.P.
Kneeland, husband and wife, whose post office address is 1203 Slocum Road, Wapwallopen, PA 18660, herein called
the grantor, to David J. Pazdur Construction LLC, a Florida limited liability company, whose post office address is:
2301 Cameron Avenue, Sanford, FL 32771, hereinafter called the grantee:
(Wherever used herein the terms "grantor" and "grantee" include all the parties to this instrument and the heirs, legal
representatives and assigns of individuals, and the successors and assigns of corporations)
W I T N E S S E T H: That the grantor, for and in consideration of the sum of TEN AND 00/100'S ($10.00) Dollars and
other valuable considerations, receipt whereof is hereby acknowledged, hereby grants, bargains, sells, aliens, remises,
releases, conveys and confirms unto the grantee all that certain land situate in SEMINOLE County, State of Florida,
described as follows:
Lot (s) 17 and 18 and the West 25 feet of Lot 19, Block 13, 2nd Section San Lanta, according to the map or
plat thereof, as recorded in Plat Book 4, Page(s) 38 through 40, inclusive, of the Public Records of Seminole
County, Florida.
Property Address: 468 Rosalia Drive, Sanford, FL 32771
Subject to covenants, conditions, restrictions, reservations, limitations, easements and agreements of record, if any, taxes
and assessments for the year 2018 and subsequent years, and to all applicable zoning ordinances and/or restrictions and
prohibitions imposed by governmental authorities, if any.
TOGETHER, with all the tenements, hereditaments and appurtenances thereto belonging or in anywise appertaining.
TO HAVE AND TO HOLD, the same in fee simple forever.
AND, the grantor hereby covenants with said grantee that the grantor is lawfully seized of said land in fee simple; that the
grantor has good right and lawful authority to sell and convey said land, and hereby fully warrants the title to said land
and will defend the same against the lawful claims of all persons whomsoever.
SIGNATURE PAGE TO FOLLOW
SIGNATURE PAGE OF WARRANTY DEED
IN WITNESS WHEREOF, the said grantor has signed and sealed these presents the day and year first above written.
Signed, sealed and delivered in the presence of -
WIN
�jT NI8 EENEY _
Witness #1 Printed Name .fairies C. Kneeland, HI
Witness #2 Signature
�G
Witness #2 Printed Name Ir
aril M.P. Kneeland
STATE OF FLORIDA
COUNTY OF 0 10
The foregoing instrument was acknowledged before me this IL day of January, 2018 b James C. Kneeland, III and
Marilyn M.P. Kneeland who are personally known to me or have produced rivers License as
identification.
Notary
My Commission Expires:
TONI SWEENEY
=,
MY COMMISSION # GG 105485
EXPIRES: August 25, 2021
Bonded Thru Notary Public Underwriters
RECORD COPY
LABORATORY
July 30, 2017
Pingsheng Zhu, P. E.
Product Compliance Engineer
James Hardie Building Products
10901 Elm Ave. 09VIEWE190 POR CODE COMPLIANCE
Fontana, CA 92337 %:7
PLANE EXAMINER
Re-, NOA-17-0406.06
Relative to FBC 2017 DATE
Project RIO-2679AA-1 7
Dear Pingsheng:
ACCREDITED
SANFORD BUILDING DIVISION
A PERMIT ISSUED SHALL BE CONSTRUED TO BE A
LICENSE TO PROCEED WITH THE WORK AND NOT AS
AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET
ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL
CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT
THE BUILDING OFFICIAL FROM THEREAFTER
REOUIRING A CORRECTION OF ERRORS IN PLANS,
CONSTRUCTION OR VIOLATIONS OF THIS CODE
After review of the 2017 FBC, it is my opinion that the current NOA-17-0406,06 is in compliance with the 2017 Florida
Building Code.
Referenced Standards in the 2017 FBC:
1. Wood: AWC NDS-2015 & SDPWS-2015
2, Structural Loads: ASCEISEI-7-10
3. Concrete: ACE-318-14 # 0 5 2
4. Masonry' TMS402-2016/AC1530-13,IASCE-5-13
S. Structural Steel: AISC 36D-10 {Including manual of steel construction 2010 (14"' edition))
,\31LD
6, Cold -formed Steel'. AISI 100-12
T Aluminum: ADNI-1 -201 5 SANFORD
In addition, I arn making the following Statement of Independence as reqUested:
4RTN
G
1, Ronald Oqowa, does not have nor does it intend to acquire or will it acquire any financ!al intereM in any company Manufacturing or
distr%uting products for which evaluations, are issued.
2. Ronald Ogawa is not awned, operated or controlled by arry company mantifacturing or distributing products It. evaluates oi, inspect.
3, Ronald Ogavva Inc does not have, nor wifl it acquire a financial interest in any company manufacturing or distributing products for
Mkin reports are beirmissued..
4. Ronald Ogawa does not have, :nor will it acquire a financial interest in any other entity Involved m the approval process of the product.
Should you have any questions on anything, please contact me,
Sincerely,
Ronald I Ogawa
RI Cigawa & Associates, Inc.
[AS Laboratory Approval, TL 360
IAS Quality Control Agency, AA-705
CRRC Approved Testing Laboratory for Solar Reflectance and Emissivity
State of Florida Approved Validator and Third Party Quality Control Agency
(714) 292-2602
CC: Roger Ogawa — RI Ogawa & Associates, Inc.
Karen Ogawa — RI Ogawa & Associates, Inc.
V )GAVV�
Lab Address, 1985 Sampson Avenue, Corona. CA 92879 a Phone (714) '�21-4939 a Fax (714) 546-181 5 a E-mail: r Zej@rpfvv,".i 01
Maiiing Address: 16835Algonquin St. #443,Hurtif)gtoii Beach, CA02CA9 - Phone (7021491-37'10- Fax (714)908-1815
Engineeiing 0 Ouality Control a Product Develapnieril # Inspections * Code Consulting * Exceit Witness * Testing
Florida
a Product
whod+ Approval
HardiePanelO Siding
• For use inside HVHZ:
o HardiePanel Siding fastener types, fastening schedule, and installation
shall be in accordance with the Miami -Dade County Florida NOA 17-
0406.06. Consult the HardiePanel product installation instructions on the
follow pages for all other installation requirements.
• For use outside of HVHZ,
o HardiePanel Siding fastener types, fastening schedule, and installation
shall be in accordance with Engineering Evaluation Reports RIO-2686-17
or RIO-2689-17. Consult the HardiePanel product installation instructions
on the follow pages for all other installation requirements. '
1
HardlmePanelo"A��19. Vehtical Siding JamesHardle
EFFECTIVE SEPTEMBER 2013
I.tiSIAL A lON EOCIF'sEb1c^. `� Es IDEN . A_ SING: Fr','I Y C PRIMED & r;r; Jf E L ; r '' jC_;' GTS
Visit arc .,h.,r( I_., o_r for the most recent version.
SMOOTH ° CEDARMILL° @ SELECT SIERRA 8 a STUCCO
IMPORTANT: FAILURE TO INSTALL, AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE
WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES,
AND VOID THE PRODUCT ONLY WARRANTY. BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS.
INSTALLATION OF HZ1 O' m PRODUCTS OUTSIDE AN HZ100 LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HA13DIEZONE APPLIES
1.0 YOUR LOCATION, VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343 (866 9HARDIE)
STORAGE & HANDLING:
Store flat and keep dry and
covered prior to installation. Installing
siding wet or saturated may result in
shrinkage at butt joints. Carry planks
on edge. Protect edges and corners
from breakage. James I lardie is not
responsible for damage caused
by improper storage and handling of
the product. F-f
OUTDOORS INDOORS
1. Position cutting station so that wind will blu:v dust away from user 1. Cut only using score and sna(), or shears (manual, electric or pneumatic).
and others in working area. 2. Position cutting station in well -ventilated area
2. Use one of the following methods:
a. Best: I. Score and snap
ii. Shears (manual, electric or pneumatic), - NEVER! se a power saw indoors
b. Better: i. Dust reducing circular saw equipped with a - NEVER use a circular save blade that does riot carry the I lardieBlade saw blade Uademai k
HardieBiade' saw blade and HEPA vacuum extraction NEVER dry sweep — Use wet suppression. or HEPA Vacuum
c. Good: i. Dust reducing circular saw with a HarcdieBlade saw blade
(only use for low to moderate cutting)
Important Note: Fur maximum protection (lowest respirable dust production). James Hardie recomntends always using "Best --level cutting methods where feasible.
NIOSH-appro ad respirators can be used in conjunction with above cutting practices to further reduce dust exposures. Additional exposure information is available
at www.jameshardie.com to help you determine the Trost appropriate cutting method for your job requirements. If concern still exists about exposure levels or you
do not comply with the above practices, you should always consult a qualified industrial hygienist or contact James Hardie for further information. s re3,ce
GENERAL REQUIREMENTS:
• These instructions to be used for residential single family installations only. For Commercial / Multi -Family installation requirements go to Nnww.JamesHardieCommel-cial.com
• HardiePanelO, vertical siding can be installed over braced wood or steel studs spaced a maximum of 24" o.c. See genernal fastening requirements. Irregularities in
framing and sheathing call mirror through the finished application. James Hardie recommends installing HardiePanel on a capillary break (rainscreen/furring) as a best practice.
• Information on installing James Hardie products over foarn can be located in JH Tech Bulletin 19 at www. lamehardie.com
• A water -resistive barrier is required in accordance With local building code requirements. Tile water -resistive barrier must be appropriately installed with
penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration. James
Hardie does manufacture HaidieWrap� Weather Barrier, a non -woven non -perforated housewrapl , which complies with building code requirements.
• When installing James Hardie products all clearance details in figs. 5,6,7,8,9,10&11 must be followed.
• Adjacent finished grade must slope away -from the building in accordance with local building codes - typically a minimum of 6" in the first 10'.
• Do not install James Hardie products, such that they may remain in contact with standing water.
• HardiePanel vertical siding may be installed on vertical wall a plicatjons only.
• DO NOT use HardiePanel vertical sidingg In Fascia or Trim applications.
• Some a plication are not suitable for RlorPlus. Refer to COIOIPILIS section pace 3.
• DO NOT use stain, oil/alkyyd base paint, or powder coating on Jarnes Harclie� Products,
• For larger projects, including commercial and multi -family projects, where the span of the wall is significant in length, the designer and/or architect should take
into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be found in the Technical Bulletin
#8 "Expansion Characteristics"at vvww.JamesHardie.com.
INSTALLATION; Joint Treatment
Fastener Requirements • Vertical Joints - Install panels in moderate contact (fig, 1), alternatively
Position fasteners 3/8" from panel edges and no closer than joints may also be covered with battens. PVC or metal jointers or
2" away from corners. Do not nail into corners. caulked (Not applicable to ColorPlus" Finish) (fig. 2).
HardiePanel Vertical Siding Installation • Horizontal Joints - Provide Z-flashing at all horizontal joints (fig. 3).
• Framing must be provided at horizontal and vertical edges for nailing. Figure 2 Figure 3
• HardiePanel vertical siding must be joined on stud. water -resistive barrier water -resistive barrier
• Double stud may be required to maintain minimum edge ? x a stud venter -resistive eater r s.;Live
nailing distances. ( 2 x a stud harrier barrier
Figure 1 r uppe panel . upper
stud tit 1/4 gap Do not 1/4gap
water -resistive %/ % Gaulle Caulk
barrier^ �~
Batten Joint "H" Joint ~Z-flashing 9
sheathing �- I HardiePanel ;
1 r,. r. vertical siding water rest tive barrier Y. f �aCJtaave
V f nd board
keep nails 4 stud r lower lower
3/8" min panel — a
from panel
edges
_ \ Figure 4
c,l .-...._.
plate j -...
leave appropriate gap between Recommendation V!'e^
y�l 3/8 panels then caulk
l — allutg Sreic 8 010vide
moderate contact Caulk Joint a d:;.tble stud it pan;l1\ JV\
► (No,. aupI cable to Coui Phr,s" Finish) onts to avoid nailing
keep fasteners 2" _. 'Apply caulk In accordance with caulk Ctrough grooves,
away from corners _ nanutacturer's writtan applirafion Ins, actionsU_
For additional information on HardieWrapII Weather Barrier, consult James Hardie at 1-866-4Hardie or vn^vw.hardiewrap.com
WARNING: AVOID BREATHING SILICA DUST
James Hardie" predicts contain respirable crystalline silica. witch is known to the State of California to cause cancer ante is ronsidered by IARC and NIOSH to be a cause of cancer from some occupational sources. Breathing
excessive amounts of respirable silica dust can also cause a disabling and ^,eternally fatal lung disease called sifcoss, and has been linked with ether diseases. some studies suggest sr:ok rg inay in:;reuse these risks. During
installation or handling: (., work in outdoor areas with ample ventilation: (2) use fiber cement shears for cutting or. where not feasible, use a ilardieBlade' saw blade and dust -reducing circular saw attached to a It vacuum:
(3) warn others in the immediate area: (4) wear a properly -fled, NIOSI I -approved dust mask or resnirator e,g, N-95) in accordance with applicable government regulations and manufacturer Instructions to further limit
respirable slica exposures During clean -rip. use r-EPA vacurms or wet cleanup nielhods - never dry sweep. Fur further information, refer to of I1Stallatinn instructions "�nd M'lre--vial Safety Doty Shur,: available at
ww.:v.jameshardie.00rn or by calling 1-800-9H.ARD1_ (1-8ti0-942-7343). FAILURE TO ADHERE TO OUR WARNINGS. MSOS, AND INSTALLATION INSTRUCTIONS M.AY LEAD TO SERIOUS PERSONAL INJURY OR DEATH.
HS1236 - P1/3 1/13
CLEARANCES
Install siding and trim products in
Maintain a minimum 1"
Maintain a minimum 1 " 2" clearance
At the juncture of the roof and vertical
Maintain a 1/4"
compliance with local building code
- 2" clearance between
between James Hardie products
surfaces, flashing and counterflashing
clearance between
for clearance between
requirementsmanufacturer's
James Hardier
and decking material.
shall be installed per the roofing
instructions. Provide a
the bottom of James
Hardie products and
the bottom edge of the siding and
products and paths:
Figure 7
minimum 1 "- 2" clearance between
horizontal flashing.
the adjacent finished grade.
steps and driveways.
the roofing and the bottom edge of the
Do not caulk gap.
stud
Figure 5
9
Figure 6
siding
III
water
rbar
siding and trim.
Figure 8
Refer to fig. 3 or:
page 1.
,�
siding F-
�.
ee
I
,'l 14' 1° - 2° min.
concrete
�, 6" f111n. I foundation
Maintain a minimum 1" gap
between gutter end caps and
siding & trim.
Figure 9
gutter and end cap
deck material
1"-2" mi
joist flashing
ledger
Do not bridge floors with HardiePanel"
siding. Horizontal
��� �� � FLASHING
joints should always be created between
floors (fig. 10).
Water-
Because of the volume of water that can pour down a sloped
Resistive
' I
roof, one of the most critical flashing details occurs where a
Fi ure 10 Barrier
g
;;; \ j
Framing roof intersects a sidewall. The roof must be flashed with step
Flooring flashing. Where the roof terminates, install a kickout to deflect
• Horizontal
Trim
water away from the siding. It is best to install a self -adhering
rnernbrane on the wall before the subfascia and trim boards
—: are nailed in place, and then come back to install the kickout.
Figure 11, Kickout Flashing To prevent water from
dumping behind the siding and the end of the roof
Sheathing
intersection, install a "kickout" as required by IRC code
_
R905.2.8.3 "...flashing shall be a min, of 4" high and 4"
fascia �' HardiePanelo
wide." James Hardie ieconinnends the klckotlt be angled
between 100' - 110' to maximize water deflection
BLOCKED PENETRATIONS
Penetrations such as hose bibs and holes 1 Y2" or larger such as dryer vents
should have a block of trim around point of penetration.
GENERAL FASTENING REQUIREMENTS
Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are
acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality,
hot -dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of
fasteners. Stainless steel fasteners are recommended when installing James Hardie products near
the ocean, large bodies of water, or in very humid climates. -
• Consult applicable product evaluation or listing for correct fastener type and placement to achieve
specific design wind loads.
• NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have
specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable
compliance documentation.
• Drive fasteners perpendicular to siding and framing.
• Fastener heads should fit snug against siding (no air space). (fig. A)
• Do not over -drive nail heads or drive nails at an angle,
• If nail is countersunk, fill nail hole and add a nail. (fig. B)
• For wood framing, under driven nails should be hit flush to the plank with a hammer (for steel
framing, remove and replace nail).
• NOTE: Whenever a structural member is present, HardiePlank should be fastened with even
spacing to the structural member. The tables allowing direct to OSB orplywood should only be
used when traditional framing is not available.
• Do not use aluminum fasteners, staples, or clipped head nails.
Snug
Flush
i A
Countersunk,
`ti.11-9
`
fill & add nail
Figure
A
Figure B
do not under
drive nails
DO NOT
STAPLE
Figure
11
�•
Sk_p 9asmna / r�� r-
Selfridheriq
membrane =� iw
-Sr If adficnng"
s r ! ewes memW.ne £
Kickout'
i flashing
Drip edge
I le�se,�rep
t
James Hardie products can be hand nailed or fastened with a
pneumatic tool. Pneumatic fastening is highly recommended.
Set air pressure so that the fastener is driven snug with the
surface of the siding. A flush mount attachment on the
pneumatic tool is recommended. This will help control the
depth the nail is driven. If setting the nail depth proves difficult,
choose a setting that under drives the nail. (Drive tinder driven
nails snug with a smooth faced hammer - Does not apply for
installation to steel framing).
HS1236 - P2/3 8/13
CAULKING
For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTIVI C834.
Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note: OSI Quad aswell as some other caulking
manufacturers do not allow tooling.
DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section
CUT EDGE TREATMENT PAINTING
Caulk, paint or prime all field cut edges. DO NOT use Stain, oivalkyd base paint, or povvder coating on James Hardier` Products. James Hardie products
James Hardie touch-up kits are required must be painted within 180 days for primed product and 90 days for unprimed. 1001% acrylic topcoats are
i
to touch-up ColorPlus products, rucortir: ivended. Do not paint when wet. Fur application rates refer to paint R13111LIfaCti specifications,
Back -rolling is recommended if the siding is sprayed.
COLORPLUS' TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE
• Care should be taken when handling and cutting James Hardie@ ColorPlus@ products. During installation use a wet soft cloth or soft brush to
gently wipe off any residue or construction dust left on the product, then rinse with a garden hose.
• Touch up nicks, scrapes and nail heads using the Colorfalus"' Technology touch-up applicator. TOLICh-UP should be used sparingly.
If large areas require touch-up, replace the damaged area with new Hard jePane ", siding with C0101'PlUs Technology.
• Laminate sheet must be removed immediately after installation of each course.
• Terminate non -factory cut edges into trim where possible, and caulk. Color matched caulks are available from Your ColorPlus"' product dealer.
• Treat all other non -factory Cut edges using the ColorPlus Technology edge coaters, available from Your ColorPlus product dealer.
Note: James Hardie does not warrant the usage of third party touch -LIP or paints used as tOUCII-LIP on James Hardie ColorPlus products,
Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie
touch-up, will not be covered under the James Hardie ColorPlus Limited Finish Warranty.
The following outlines the recommended applications for ColorPlus and Primed panels. Not all designs will be suitable for
every application:
• Exposed fasteners or battens is the recommended application for ColorPlus panel products
• Do not use touch-up over fastener heads for smooth ColorPlus products - primed panel recommended
• For ColorPlus panel applications that require fasteners in the field, it is acceptable to use touch -Up over fasteners for Cedarmill and Stucco panel
only, but correct touch-up application is important. Some colors may show touch-up when applied over fasteners. Trim is recommended. to cover
joints when appropriate.
PAINTING JAMES HARDF-"" SIDING AND TRIM PRODUCTS WITH COLORPLUS" TECHNOLOGY
When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application:
• Ensure the surface is clean, dry, and free of any dust, dirt, or mildew
• Repriming is normally not necessary
• 100% acrylic topcoats are recommended
• DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie" Products
• Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application
temperature
R0JGNIf ION: In accordance vvith I CC-LS EvalLial" On He JOr: FSR-1844. HardiePanel's', vertical siding is re cog: iized as, sjititle alienate tc that speared in, the 2006.20019, & 2012 InleirvIonal Residential 'code for One -and
vo-Faintly Dwellings and the 2006. 2009, & 2012 IW6rn3tiO11aI Build:nq "odp. 3rdpi`ariel vRintical siding is also recognized for applicat on in the following: rl':by of Los Angeles Reseai6 Rep)rT No. 24d62 Sate Of Florida
3 a
I:SL::'g ECK Dade Couriby. FLridaNOANo. 02-0729,02, U.S. "Depl. ofHOIDWerialsRelease 1263r.,7ex@sDepartme.ito`lq�,Lfrane Produci EC-23, and Cilif rNal)SAPA- 19,
: hose documents should alsoop consui,ed fol additik"14 :r)fo(nlrrt:on concrwing the "Jilability Of thy, riodA fol spedfic applionoi,,,,
0 2013 James Hardie Building Products, All rights reserved.
TM. SM, and ®R denote trademarks or registered trademarks of
James I lardieTechnology Limited ;1 is a registered
trademark of James Hardie Technology Limited.
Additional Installation Information
Warranties, and Warnings are available at James
wwvjarneshardie.corn
HS1236-P3/3 6/13
B0UNOARY 5URVEY FOR: /c'�t/ "� ,r .t./ ,J%�+,;:<";°��, ". r`ltl"lzy/vNP
DESCRIPTION: LOTS 17.18 AND THE WEST 25 FEET OF LOT 19. BLOCK l3. 2ND. SECTION SAN
LANTA. AS RECORDED IN PLAT BOOK 4. PAGES 38-40 OF THE PUBLIC RECORDS
OF SEMINOLE COUNTY. FLORIDA.
16
14. _o I z,>. 93' A a02- 23' F
CH. BRO. . _ . L 30. 26' .
46CHORO-130, yg,
84' (a 3" W. (C. )
VSAW
WACCERTY LANDVEYINORANGEVENUEO. B0X234y" 22 ZZJJ$$2? i6300F. (i07)3??-8611
0
ROSE L d Dom_ I V v
'OPEN-PAVEDI
I. THIS PROPERTY LIES IN FLOOD ZONES($) .X PER
NUIEA.M.ASIFLOODZOtnyRt10t�EERATE NAP. COMMUNITY -PANEL
BER(DATED 4-17-95
2. TITLE DATA HAS NOT BEEN FURNISHED TO THE SURVEYOR.
3. UNDERGROUND IMPROVEMENTS ARE NOT LOCATED.
4. NOT VALID UNLESS SEALED WITH AN EMBOSSED SEAL.
5. THIS PROPERTY LIES IN SECTION(S) JI
TOWNSHIP /9 SOUTH.RANGE 3I EAST.
LEGEND
REC DENOTES
RECOVERED
C.B.
CONCRETE BLOCK
C.M.
CONCRETE MONUMENT
W.F.
WOOD FRAME
I.P.
IRON PIPE
RES.
RESIDENCE
I.R.
IRON ROD
CONC.
CONCRETE
N.C.
NAIL AND CAP
A.C.
AIR CONDITIONER
P.O.C.
POINT OF COMMENCEMENT
UTIL.
UTILITY
P.O.B.
POINT OF BEGINNING
DRAIN.
DRAINAGE
CL
CENTERLINE
ESMT. -
EASEMENT
R/W
RIGHT-OF-WAY
L.S.
LICENSED SURVEYOR
(R.)
RADIAL
L.B.
LICENSED BUSINESS
(N.R.)
NON RADIAL
P.
PLAT
R.P.
RADIUS POINT
M.
MEASURED
P.C.
POINT OF CURVATURE
D.
DESCRIPTION
P.T.
POINT OF TANGENCY
C.
CALCULATED
P.R.C.
POINT OF REVERSE
A.
R.
ACTUAL,
RADIUS
P.C.C. -
CURVATURE
POINT OF COMPOUND
L.
LENGTH
CURVATURE
A
DELTA,_
C.L.
CHAIN LINK4,
20
SCALE: I'-30'
DATE OF
BOUNDARY:
FOUND.: 2—/8—f0
FINAL:
--- i/W--
CERTIFIED CORRECT T0:
""S-5 G'• A-A1_-ELgA/O, ZZ MEP/Lyf/ All'!
.Y.VEEL.pA/O CouvreywioE,yol,E
L0.4A/S, /A/C. j
F/RST AMER/CA.(/ T/TLE i.VSURAvcG'
I HEREBY CERTIFY THAT THE SURVEY SHOWN
HEREON WAS MADE IN ACCORDANCE TO THE
'MINIMUM TECHNICAL STANDARDS' FOR
LAND SURVEYING IN THE STATE OF FLORIDA
CH.472.027 AND CH.61G17-6.
b
REGISTERED LAND 5 fY N0.3764
R1EQU1RE D PTS1P1EC•TION SEQUENCE
IB1P# 0 — -,<7 Artidirlesn: L1(61%
Min Max fnseefllon Desen'Il Lion.
Footer / Setback
Stemwall
Foundation / Form Board.'Survey
Slab !Mono Slab Prepour
Lintel / Tie Beam / Fill / Down Cell
Sheathing— Walls
Sheathing— Roof
Roof Dry In
Frame
Insulation Rough In
Firewall Screw Pattern
Drywall / Sheetrock
Lath Inspection
Final Solar
Final Roof
Final Stucco / Siding
Insulation Final
Final Utility Building -
Final Door
Final Window
Final Screen.Room
Final. Pool Screen Enclosure
Mobile Home Building Final
Pre -Demo
Final Demo
Final Single Family Residence
Final. Building. Other
R EVIIS1ED: June 20'14
Mn
Max:
Inms2ecdon.11Descri2flon
Electric. Underground
Footer [Slab Steel Bond
Electric Rough
T.U.G.
Pre -Power Final
Electric Final '
" Ye :% :.ppgy„v
....
`L'tai' KN Apr
w.... .S .J:P.
• (M(�{,' �„S,? NAGtl µ (rY,.�^�� )�+. u"g�S'--zam 'A �AIiFNl' 7;;�;c�¢1i�'i4frz
Y..Sysi��i"'[J�:^r
liras Decfn®n 11Descn•It2tion
Min
Mays'
Plumbing Underground
Plumbing Sewer
Plumbing Tub Set
Plumbing Final
.........._
1�1� 11\ I� •\I ���II:\III
��IIII ��'I\ III �II I�IIQ III ►nl �IllIIIIWIII
—�Mechanical
Rough
Mechanical. Final
G`�i ,��"i"".wb'Y
�.
e,s•�4.e7�' '�`v`}5n,�,�ly+.i2u�.st ;r>>grysrl-1=57i
SG« ,�..�ir,'.cs�r9 rkn.�•.�Ynas _5t4 7., e•,..FI,r..?Sii r
ttt
.�'�.
Gas Underground
�-GasRough
._....�-
CITY OF ,
SkNFORD Building & Fire Prevention Division
RESIDENTIAL RE-R0OFAFFIDAVI7
FIRE DEPARTMENT
RESIDENTIAL RE -ROOF INSPECTION AFFIDAVIT
NAILING, SHEATHING, DRY -IN, FLASHING, AND ALL FINAL ROOF COVERINGS
4u1 PERMIT #: olb2" ADDRESS: 462p '�O SA0\,
5m4mro 17L
11y�+r , ", N , AS A(N) GENERAL, BUILDING, RESIDENTIAL, OR
ROOFING CONTRACTOR, ENGINEER, ARCHITECT, OF F.S. CHAPTER 468 BUILDING INSPECTOR, I HEREBY AFFIRM, THAT ALL OF THE
FOREGOING INFORMATION IS TRUE AND ACCURATE AND THAT ALL ROOFING COMPONENTS LISTED ON THE SCOPE OF WORK AT THE
ABOVE REFERENCED ADDRESS HAVE BEEN INSTALLED IN ACCORDANCE WITH THEIR PRODUCT APPROVALS AND ALL APPLICABLE CODE
REQUIREMENTS — SPECIFICALLY FLORIDA BUILDING CODE, EXISTING BUILDING. IN ADDITION I CERTIFY THE INSTALLATION MEETS ALL
REQUIREMENTS FOR SECONDARY WATER BARRIER AND NAILING OF THE ROOF DECK, IN ACCORDANCE WITH THE HURRICANE RETROFIT
MANUAL REQUIREMENTS (BASED ON F.S. CHAPTER 553.844).
LICENSEA:
COMPANY / CONTRA
CONTRACTOR SIGNA
(MUST BE SIGNED B
Y
CTOR:
TU E: DATE: / 0
LICEN LDER UILDER)
A FINAL ROOF INSPECTION IS REQUIRED:
THIS SIGNED AND NOTARIZED AFFIDAVIT MUST BE PROVIDED AT THE JOB SITE AT THE TIME OF THE FINAL ROOF INSPECTION,
ALONG WITH DIGITAL PHOTOGRAPHS OF EACH PLANE OF THE ROOF SHOWING IN DETAIL ALL COMPONENTS (DECKING,
UNDERLAYMENT, FLASHING, DRIP EDGE ATTACHMENT) WITH THE PERMIT NUMBER OR ADDRESS CLEARLY MARKED ON THE DECK
FOR EACH INSPECTION. THE PHOTOGRAPHS MUST INCLUDE A RULER OR MEASURING DEVICE TO CONFIRM ALL NAIL SPACING AND
OVERLAPS, INCLUDING DRIP EDGE AND VALLEY FLASHING. PLEASE REFER TO THE RE -ROOF POLICY AND INSPECTION PROCEDURE
PAPERWORK FOR FURTHER EXPLANATION OF ALL REQUIREMENTS.
**FAILURE TO FOLLOW ALL REQUIREMENTS WILL RESULT IN A FAILED INSPECTION, A RE-INSPECTION'FEE AS
WELL AS REQUIRING A DESIGN PROFESSIONAL (ARCHITECT OR ENGINEER) TO CERTIFY, BASED ON PERSONAL
INSPECTION, THE INSTALLATION OF ALL ROOFING COMPONENTS.
STATE OF FLORIDA COUNTY OF �eK dll�
Sworn to and Subscribed before me this � day of r, 20 14' by:
V/d / ,2 d." ,— Who is 1�ersonally Known to me or has ❑ Produced (type of
identification)
Signature of Notary Public
State of Florida
1%,-a- Ca. (d cw e
Print/Type/Stamp Name
of Notary Public
as identification.
............
VERA A CAD102121
.�..:
Notary Public- S
• : (
Commission >rMy
Comm. ExpirHanded
throughNat