Loading...
HomeMy WebLinkAbout468 Rosalia Dr (2).-7 CITY OF' SkNFORDBuilding & Fire Prevention Division FEB Z 1�11� PERMIT APPLICATION Application No: .Documented Construction Value: $ 1200.00 Job Address: 468 Rosalia Drive Historic District: Yes❑No7 Parcel ID: 31-19-31-508-1300-0170 Residential Commercial❑ Type of Work: New[] Addition ✓❑ Alteration[] Repair❑ Demo❑ Change of Use Move❑ Description of Work: Reside gable ends and garage wall. &% f,�C Plan Review Contact Person: Phone: 321 377 6105 David Title: Owner Fax: N/A Email: dpazdur@msn.com Property Owner Information Name David J. Pazdur Construction LLC Phone: 321 377 6105 Street: 2301 Cameron Ave. City, State Zip: Sanford, FI. 32771 Resident of property? : Contractor Information Name David J. Pazdur Construction LLC Phone: 321 377 6105 Street: 2301 Cameron Ave. City, State Zip: Sanford, Fl. 32771 Name: N/A Street: City, St, Zip: Bonding Company: N/A Address: No Fax: N/A State License No.: CRC038083 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: N/A Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6th Edition (2017) Florida Building Code Revised: January I, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. �16 / Signature of Owner/Agent Date Signatur of Co ractor/Agent D to Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Name J,,non,1,acto,/Agcnt's Z_ Z(p- 1 Signature of Nota "' "'•. ANNETTE N1 BLAND Notary Public - State of Florida Commissior tt GG 17090C My Corrrr. Expires Jar 16, 2022 5crcec:hrc_crtia�cra NoarvAssn. Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas❑ Roof ❑ Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Flood Zone: # of Stories: Plumbing - # of Fixtures, Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: 5F 4.1. 1 Revised: January I, 2018 Permit Application This Instrument Prepared by and Return to: John Taylor Fassett, Anthony & Taylor, P.A. 1325 W. Colonial Dr. Orlando, FL 32804 Our File No.: 4529-170 (Toni Sweeney) Property Appraisers Parcel Identification (Folio) Numbers: 31-19-31-508-1300-0170 SPACE ABOVE THIS LINE FOR RECORDING DATA THIS WARRANTY DEED, made the 31 st day of January, 2018 by James C. Kneeland, III and Marilyn M.P. Kneeland, husband and wife, whose post office address is 1203 Slocum Road, Wapwallopen, PA 18660, herein called the grantor, to David J. Pazdur Construction LLC, a Florida limited liability company, whose post office address is: 2301 Cameron Avenue, Sanford, FL 32771, hereinafter called the grantee: (Wherever used herein the terms "grantor" and "grantee" include all the parties to this instrument and the heirs, legal representatives and assigns of individuals, and the successors and assigns of corporations) W I T N E S S E T H: That the grantor, for and in consideration of the sum of TEN AND 00/100'S ($10.00) Dollars and other valuable considerations, receipt whereof is hereby acknowledged, hereby grants, bargains, sells, aliens, remises, releases, conveys and confirms unto the grantee all that certain land situate in SEMINOLE County, State of Florida, described as follows: Lot (s) 17 and 18 and the West 25 feet of Lot 19, Block 13, 2nd Section San Lanta, according to the map or plat thereof, as recorded in Plat Book 4, Page(s) 38 through 40, inclusive, of the Public Records of Seminole County, Florida. Property Address: 468 Rosalia Drive, Sanford, FL 32771 Subject to covenants, conditions, restrictions, reservations, limitations, easements and agreements of record, if any, taxes and assessments for the year 2018 and subsequent years, and to all applicable zoning ordinances and/or restrictions and prohibitions imposed by governmental authorities, if any. TOGETHER, with all the tenements, hereditaments and appurtenances thereto belonging or in anywise appertaining. TO HAVE AND TO HOLD, the same in fee simple forever. AND, the grantor hereby covenants with said grantee that the grantor is lawfully seized of said land in fee simple; that the grantor has good right and lawful authority to sell and convey said land, and hereby fully warrants the title to said land and will defend the same against the lawful claims of all persons whomsoever. SIGNATURE PAGE TO FOLLOW SIGNATURE PAGE OF WARRANTY DEED IN WITNESS WHEREOF, the said grantor has signed and sealed these presents the day and year first above written. Signed, sealed and delivered in the presence of - WIN �jT NI8 EENEY _ Witness #1 Printed Name .fairies C. Kneeland, HI Witness #2 Signature �G Witness #2 Printed Name Ir aril M.P. Kneeland STATE OF FLORIDA COUNTY OF 0 10 The foregoing instrument was acknowledged before me this IL day of January, 2018 b James C. Kneeland, III and Marilyn M.P. Kneeland who are personally known to me or have produced rivers License as identification. Notary My Commission Expires: TONI SWEENEY =, MY COMMISSION # GG 105485 EXPIRES: August 25, 2021 Bonded Thru Notary Public Underwriters RECORD COPY LABORATORY July 30, 2017 Pingsheng Zhu, P. E. Product Compliance Engineer James Hardie Building Products 10901 Elm Ave. 09VIEWE190 POR CODE COMPLIANCE Fontana, CA 92337 %:7 PLANE EXAMINER Re-, NOA-17-0406.06 Relative to FBC 2017 DATE Project RIO-2679AA-1 7 Dear Pingsheng: ACCREDITED SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REOUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE After review of the 2017 FBC, it is my opinion that the current NOA-17-0406,06 is in compliance with the 2017 Florida Building Code. Referenced Standards in the 2017 FBC: 1. Wood: AWC NDS-2015 & SDPWS-2015 2, Structural Loads: ASCEISEI-7-10 3. Concrete: ACE-318-14 # 0 5 2 4. Masonry' TMS402-2016/AC1530-13,IASCE-5-13 S. Structural Steel: AISC 36D-10 {Including manual of steel construction 2010 (14"' edition)) ,\31LD 6, Cold -formed Steel'. AISI 100-12 T Aluminum: ADNI-1 -201 5 SANFORD In addition, I arn making the following Statement of Independence as reqUested: 4RTN G 1, Ronald Oqowa, does not have nor does it intend to acquire or will it acquire any financ!al intereM in any company Manufacturing or distr%uting products for which evaluations, are issued. 2. Ronald Ogawa is not awned, operated or controlled by arry company mantifacturing or distributing products It. evaluates oi, inspect. 3, Ronald Ogavva Inc does not have, nor wifl it acquire a financial interest in any company manufacturing or distributing products for Mkin reports are beirmissued.. 4. Ronald Ogawa does not have, :nor will it acquire a financial interest in any other entity Involved m the approval process of the product. Should you have any questions on anything, please contact me, Sincerely, Ronald I Ogawa RI Cigawa & Associates, Inc. [AS Laboratory Approval, TL 360 IAS Quality Control Agency, AA-705 CRRC Approved Testing Laboratory for Solar Reflectance and Emissivity State of Florida Approved Validator and Third Party Quality Control Agency (714) 292-2602 CC: Roger Ogawa — RI Ogawa & Associates, Inc. Karen Ogawa — RI Ogawa & Associates, Inc. V )GAVV� Lab Address, 1985 Sampson Avenue, Corona. CA 92879 a Phone (714) '�21-4939 a Fax (714) 546-181 5 a E-mail: r Zej@rpfvv,".i 01 Maiiing Address: 16835Algonquin St. #443,Hurtif)gtoii Beach, CA02CA9 - Phone (7021491-37'10- Fax (714)908-1815 Engineeiing 0 Ouality Control a Product Develapnieril # Inspections * Code Consulting * Exceit Witness * Testing Florida a Product whod+ Approval HardiePanelO Siding • For use inside HVHZ: o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami -Dade County Florida NOA 17- 0406.06. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. • For use outside of HVHZ, o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Reports RIO-2686-17 or RIO-2689-17. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. ' 1 HardlmePanelo"A��19. Vehtical Siding JamesHardle EFFECTIVE SEPTEMBER 2013 I.tiSIAL A lON EOCIF'sEb1c^. `� Es IDEN . A_ SING: Fr','I Y C PRIMED & r;r; Jf E L ; r '' jC_;' GTS Visit arc .,h.,r( I_., o_r for the most recent version. SMOOTH ° CEDARMILL° @ SELECT SIERRA 8 a STUCCO IMPORTANT: FAILURE TO INSTALL, AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY. BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS. INSTALLATION OF HZ1 O' m PRODUCTS OUTSIDE AN HZ100 LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HA13DIEZONE APPLIES 1.0 YOUR LOCATION, VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343 (866 9HARDIE) STORAGE & HANDLING: Store flat and keep dry and covered prior to installation. Installing siding wet or saturated may result in shrinkage at butt joints. Carry planks on edge. Protect edges and corners from breakage. James I lardie is not responsible for damage caused by improper storage and handling of the product. F-f OUTDOORS INDOORS 1. Position cutting station so that wind will blu:v dust away from user 1. Cut only using score and sna(), or shears (manual, electric or pneumatic). and others in working area. 2. Position cutting station in well -ventilated area 2. Use one of the following methods: a. Best: I. Score and snap ii. Shears (manual, electric or pneumatic), - NEVER! se a power saw indoors b. Better: i. Dust reducing circular saw equipped with a - NEVER use a circular save blade that does riot carry the I lardieBlade saw blade Uademai k HardieBiade' saw blade and HEPA vacuum extraction NEVER dry sweep — Use wet suppression. or HEPA Vacuum c. Good: i. Dust reducing circular saw with a HarcdieBlade saw blade (only use for low to moderate cutting) Important Note: Fur maximum protection (lowest respirable dust production). James Hardie recomntends always using "Best --level cutting methods where feasible. NIOSH-appro ad respirators can be used in conjunction with above cutting practices to further reduce dust exposures. Additional exposure information is available at www.jameshardie.com to help you determine the Trost appropriate cutting method for your job requirements. If concern still exists about exposure levels or you do not comply with the above practices, you should always consult a qualified industrial hygienist or contact James Hardie for further information. s re3,ce GENERAL REQUIREMENTS: • These instructions to be used for residential single family installations only. For Commercial / Multi -Family installation requirements go to Nnww.JamesHardieCommel-cial.com • HardiePanelO, vertical siding can be installed over braced wood or steel studs spaced a maximum of 24" o.c. See genernal fastening requirements. Irregularities in framing and sheathing call mirror through the finished application. James Hardie recommends installing HardiePanel on a capillary break (rainscreen/furring) as a best practice. • Information on installing James Hardie products over foarn can be located in JH Tech Bulletin 19 at www. lamehardie.com • A water -resistive barrier is required in accordance With local building code requirements. Tile water -resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration. James Hardie does manufacture HaidieWrap� Weather Barrier, a non -woven non -perforated housewrapl , which complies with building code requirements. • When installing James Hardie products all clearance details in figs. 5,6,7,8,9,10&11 must be followed. • Adjacent finished grade must slope away -from the building in accordance with local building codes - typically a minimum of 6" in the first 10'. • Do not install James Hardie products, such that they may remain in contact with standing water. • HardiePanel vertical siding may be installed on vertical wall a plicatjons only. • DO NOT use HardiePanel vertical sidingg In Fascia or Trim applications. • Some a plication are not suitable for RlorPlus. Refer to COIOIPILIS section pace 3. • DO NOT use stain, oil/alkyyd base paint, or powder coating on Jarnes Harclie� Products, • For larger projects, including commercial and multi -family projects, where the span of the wall is significant in length, the designer and/or architect should take into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be found in the Technical Bulletin #8 "Expansion Characteristics"at vvww.JamesHardie.com. INSTALLATION; Joint Treatment Fastener Requirements • Vertical Joints - Install panels in moderate contact (fig, 1), alternatively Position fasteners 3/8" from panel edges and no closer than joints may also be covered with battens. PVC or metal jointers or 2" away from corners. Do not nail into corners. caulked (Not applicable to ColorPlus" Finish) (fig. 2). HardiePanel Vertical Siding Installation • Horizontal Joints - Provide Z-flashing at all horizontal joints (fig. 3). • Framing must be provided at horizontal and vertical edges for nailing. Figure 2 Figure 3 • HardiePanel vertical siding must be joined on stud. water -resistive barrier water -resistive barrier • Double stud may be required to maintain minimum edge ? x a stud venter -resistive eater r s.;Live nailing distances. ( 2 x a stud harrier barrier Figure 1 r uppe panel . upper stud tit 1/4 gap Do not 1/4gap water -resistive %/ % Gaulle Caulk barrier^ �~ Batten Joint "H" Joint ~Z-flashing 9 sheathing �- I HardiePanel ; 1 r,. r. vertical siding water rest tive barrier Y. f �aCJtaave V f nd board keep nails 4 stud r lower lower 3/8" min panel — a from panel edges _ \ Figure 4 c,l .-...._. plate j -... leave appropriate gap between Recommendation V!'e^ y�l 3/8 panels then caulk l — allutg Sreic 8 010vide moderate contact Caulk Joint a d:;.tble stud it pan;l1\ JV\ ► (No,. aupI cable to Coui Phr,s" Finish) onts to avoid nailing keep fasteners 2" _. 'Apply caulk In accordance with caulk Ctrough grooves, away from corners _ nanutacturer's writtan applirafion Ins, actionsU_ For additional information on HardieWrapII Weather Barrier, consult James Hardie at 1-866-4Hardie or vn^vw.hardiewrap.com WARNING: AVOID BREATHING SILICA DUST James Hardie" predicts contain respirable crystalline silica. witch is known to the State of California to cause cancer ante is ronsidered by IARC and NIOSH to be a cause of cancer from some occupational sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and ^,eternally fatal lung disease called sifcoss, and has been linked with ether diseases. some studies suggest sr:ok rg inay in:;reuse these risks. During installation or handling: (., work in outdoor areas with ample ventilation: (2) use fiber cement shears for cutting or. where not feasible, use a ilardieBlade' saw blade and dust -reducing circular saw attached to a It vacuum: (3) warn others in the immediate area: (4) wear a properly -fled, NIOSI I -approved dust mask or resnirator e,g, N-95) in accordance with applicable government regulations and manufacturer Instructions to further limit respirable slica exposures During clean -rip. use r-EPA vacurms or wet cleanup nielhods - never dry sweep. Fur further information, refer to of I1Stallatinn instructions "�nd M'lre--vial Safety Doty Shur,: available at ww.:v.jameshardie.00rn or by calling 1-800-9H.ARD1_ (1-8ti0-942-7343). FAILURE TO ADHERE TO OUR WARNINGS. MSOS, AND INSTALLATION INSTRUCTIONS M.AY LEAD TO SERIOUS PERSONAL INJURY OR DEATH. HS1236 - P1/3 1/13 CLEARANCES Install siding and trim products in Maintain a minimum 1" Maintain a minimum 1 " 2" clearance At the juncture of the roof and vertical Maintain a 1/4" compliance with local building code - 2" clearance between between James Hardie products surfaces, flashing and counterflashing clearance between for clearance between requirementsmanufacturer's James Hardier and decking material. shall be installed per the roofing instructions. Provide a the bottom of James Hardie products and the bottom edge of the siding and products and paths: Figure 7 minimum 1 "- 2" clearance between horizontal flashing. the adjacent finished grade. steps and driveways. the roofing and the bottom edge of the Do not caulk gap. stud Figure 5 9 Figure 6 siding III water rbar siding and trim. Figure 8 Refer to fig. 3 or: page 1. ,� siding F- �. ee I ,'l 14' 1° - 2° min. concrete �, 6" f111n. I foundation Maintain a minimum 1" gap between gutter end caps and siding & trim. Figure 9 gutter and end cap deck material 1"-2" mi joist flashing ledger Do not bridge floors with HardiePanel" siding. Horizontal ��� �� � FLASHING joints should always be created between floors (fig. 10). Water- Because of the volume of water that can pour down a sloped Resistive ' I roof, one of the most critical flashing details occurs where a Fi ure 10 Barrier g ;;; \ j Framing roof intersects a sidewall. The roof must be flashed with step Flooring flashing. Where the roof terminates, install a kickout to deflect • Horizontal Trim water away from the siding. It is best to install a self -adhering rnernbrane on the wall before the subfascia and trim boards —: are nailed in place, and then come back to install the kickout. Figure 11, Kickout Flashing To prevent water from dumping behind the siding and the end of the roof Sheathing intersection, install a "kickout" as required by IRC code _ R905.2.8.3 "...flashing shall be a min, of 4" high and 4" fascia �' HardiePanelo wide." James Hardie ieconinnends the klckotlt be angled between 100' - 110' to maximize water deflection BLOCKED PENETRATIONS Penetrations such as hose bibs and holes 1 Y2" or larger such as dryer vents should have a block of trim around point of penetration. GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot -dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie products near the ocean, large bodies of water, or in very humid climates. - • Consult applicable product evaluation or listing for correct fastener type and placement to achieve specific design wind loads. • NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable compliance documentation. • Drive fasteners perpendicular to siding and framing. • Fastener heads should fit snug against siding (no air space). (fig. A) • Do not over -drive nail heads or drive nails at an angle, • If nail is countersunk, fill nail hole and add a nail. (fig. B) • For wood framing, under driven nails should be hit flush to the plank with a hammer (for steel framing, remove and replace nail). • NOTE: Whenever a structural member is present, HardiePlank should be fastened with even spacing to the structural member. The tables allowing direct to OSB orplywood should only be used when traditional framing is not available. • Do not use aluminum fasteners, staples, or clipped head nails. Snug Flush i A Countersunk, `ti.11-9 ` fill & add nail Figure A Figure B do not under drive nails DO NOT STAPLE Figure 11 �• Sk_p 9asmna / r�� r- Selfridheriq membrane =� iw -Sr If adficnng" s r ! ewes memW.ne £ Kickout' i flashing Drip edge I le�se,�rep t James Hardie products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachment on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive tinder driven nails snug with a smooth faced hammer - Does not apply for installation to steel framing). HS1236 - P2/3 8/13 CAULKING For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTIVI C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note: OSI Quad aswell as some other caulking manufacturers do not allow tooling. DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section CUT EDGE TREATMENT PAINTING Caulk, paint or prime all field cut edges. DO NOT use Stain, oivalkyd base paint, or povvder coating on James Hardier` Products. James Hardie products James Hardie touch-up kits are required must be painted within 180 days for primed product and 90 days for unprimed. 1001% acrylic topcoats are i to touch-up ColorPlus products, rucortir: ivended. Do not paint when wet. Fur application rates refer to paint R13111LIfaCti specifications, Back -rolling is recommended if the siding is sprayed. COLORPLUS' TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE • Care should be taken when handling and cutting James Hardie@ ColorPlus@ products. During installation use a wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product, then rinse with a garden hose. • Touch up nicks, scrapes and nail heads using the Colorfalus"' Technology touch-up applicator. TOLICh-UP should be used sparingly. If large areas require touch-up, replace the damaged area with new Hard jePane ", siding with C0101'PlUs Technology. • Laminate sheet must be removed immediately after installation of each course. • Terminate non -factory cut edges into trim where possible, and caulk. Color matched caulks are available from Your ColorPlus"' product dealer. • Treat all other non -factory Cut edges using the ColorPlus Technology edge coaters, available from Your ColorPlus product dealer. Note: James Hardie does not warrant the usage of third party touch -LIP or paints used as tOUCII-LIP on James Hardie ColorPlus products, Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up, will not be covered under the James Hardie ColorPlus Limited Finish Warranty. The following outlines the recommended applications for ColorPlus and Primed panels. Not all designs will be suitable for every application: • Exposed fasteners or battens is the recommended application for ColorPlus panel products • Do not use touch-up over fastener heads for smooth ColorPlus products - primed panel recommended • For ColorPlus panel applications that require fasteners in the field, it is acceptable to use touch -Up over fasteners for Cedarmill and Stucco panel only, but correct touch-up application is important. Some colors may show touch-up when applied over fasteners. Trim is recommended. to cover joints when appropriate. PAINTING JAMES HARDF-"" SIDING AND TRIM PRODUCTS WITH COLORPLUS" TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: • Ensure the surface is clean, dry, and free of any dust, dirt, or mildew • Repriming is normally not necessary • 100% acrylic topcoats are recommended • DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie" Products • Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature R0JGNIf ION: In accordance vvith I CC-LS EvalLial" On He JOr: FSR-1844. HardiePanel's', vertical siding is re cog: iized as, sjititle alienate tc that speared in, the 2006.20019, & 2012 InleirvIonal Residential 'code for One -and vo-Faintly Dwellings and the 2006. 2009, & 2012 IW6rn3tiO11aI Build:nq "odp. 3rdpi`ariel vRintical siding is also recognized for applicat on in the following: rl':by of Los Angeles Reseai­6 Rep)rT No. 24d62 Sate Of Florida 3 a I:SL::'g ECK Dade Couriby. FLridaNOANo. 02-0729,02, U.S. "Depl. ofHOIDWerialsRelease 1263r.,7ex@sDepartme.ito`lq�,Lfrane Produci EC-23, and Cilif rNal)SAPA- 19, : hose documents should alsoop consui,ed fol additik"14 :r)fo(nlrrt:on concrwing the "Jilability Of thy, riodA fol spedfic applionoi,,,, 0 2013 James Hardie Building Products, All rights reserved. TM. SM, and ®R denote trademarks or registered trademarks of James I lardieTechnology Limited ;1 is a registered trademark of James Hardie Technology Limited. Additional Installation Information Warranties, and Warnings are available at James wwvjarneshardie.corn HS1236-P3/3 6/13 B0UNOARY 5URVEY FOR: /c'�t/ "� ,r .t./ ,J%�+,;:<";°��, ". r`ltl"lzy/vNP DESCRIPTION: LOTS 17.18 AND THE WEST 25 FEET OF LOT 19. BLOCK l3. 2ND. SECTION SAN LANTA. AS RECORDED IN PLAT BOOK 4. PAGES 38-40 OF THE PUBLIC RECORDS OF SEMINOLE COUNTY. FLORIDA. 16 14. _o I z,>. 93' A a02- 23' F CH. BRO. . _ . L 30. 26' . 46CHORO-130, yg, 84' (a 3" W. (C. ) VSAW WACCERTY LANDVEYINORANGEVENUEO. B0X234y" 22 ZZJJ$$2? i6300F. (i07)3??-8611 0 ROSE L d Dom_ I V v 'OPEN-PAVEDI I. THIS PROPERTY LIES IN FLOOD ZONES($) .X PER NUIEA.M.ASIFLOODZOtnyRt10t�EERATE NAP. COMMUNITY -PANEL BER(DATED 4-17-95 2. TITLE DATA HAS NOT BEEN FURNISHED TO THE SURVEYOR. 3. UNDERGROUND IMPROVEMENTS ARE NOT LOCATED. 4. NOT VALID UNLESS SEALED WITH AN EMBOSSED SEAL. 5. THIS PROPERTY LIES IN SECTION(S) JI TOWNSHIP /9 SOUTH.RANGE 3I EAST. LEGEND REC DENOTES RECOVERED C.B. CONCRETE BLOCK C.M. CONCRETE MONUMENT W.F. WOOD FRAME I.P. IRON PIPE RES. RESIDENCE I.R. IRON ROD CONC. CONCRETE N.C. NAIL AND CAP A.C. AIR CONDITIONER P.O.C. POINT OF COMMENCEMENT UTIL. UTILITY P.O.B. POINT OF BEGINNING DRAIN. DRAINAGE CL CENTERLINE ESMT. - EASEMENT R/W RIGHT-OF-WAY L.S. LICENSED SURVEYOR (R.) RADIAL L.B. LICENSED BUSINESS (N.R.) NON RADIAL P. PLAT R.P. RADIUS POINT M. MEASURED P.C. POINT OF CURVATURE D. DESCRIPTION P.T. POINT OF TANGENCY C. CALCULATED P.R.C. POINT OF REVERSE A. R. ACTUAL, RADIUS P.C.C. - CURVATURE POINT OF COMPOUND L. LENGTH CURVATURE A DELTA,_ C.L. CHAIN LINK4, 20 SCALE: I'-30' DATE OF BOUNDARY: FOUND.: 2—/8—f0 FINAL: --- i/W-- CERTIFIED CORRECT T0: ""S-5 G'• A-A1_-ELgA/O, ZZ MEP/Lyf/ All'! .Y.VEEL.pA/O CouvreywioE,yol,E L0.4A/S, /A/C. j F/RST AMER/CA.(/ T/TLE i.VSURAvcG' I HEREBY CERTIFY THAT THE SURVEY SHOWN HEREON WAS MADE IN ACCORDANCE TO THE 'MINIMUM TECHNICAL STANDARDS' FOR LAND SURVEYING IN THE STATE OF FLORIDA CH.472.027 AND CH.61G17-6. b REGISTERED LAND 5 fY N0.3764 R1EQU1RE D PTS1P1EC•TION SEQUENCE IB1P# 0 — -,<7 Artidirlesn: L1(61% Min Max fnseefllon Desen'Il Lion. Footer / Setback Stemwall Foundation / Form Board.'Survey Slab !Mono Slab Prepour Lintel / Tie Beam / Fill / Down Cell Sheathing— Walls Sheathing— Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Roof Final Stucco / Siding Insulation Final Final Utility Building - Final Door Final Window Final Screen.Room Final. Pool Screen Enclosure Mobile Home Building Final Pre -Demo Final Demo Final Single Family Residence Final. Building. Other R EVIIS1ED: June 20'14 Mn Max: Inms2ecdon.11Descri2flon Electric. Underground Footer [Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final ' " Ye :% :.ppgy„v .... `L'tai' KN Apr w.... .S .J:P. • (M(�{,' �„S,? NAGtl µ (rY,.�^�� )�+. u"g�S'--zam 'A �AIiFNl' 7;;�;c�¢1i�'i4frz Y..Sysi��i"'[J�:^r liras Decfn®n 11Descn•It2tion Min Mays' Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final .........._ 1�1� 11\ I� •\I ���II:\III ��IIII ��'I\ III �II I�IIQ III ►nl �IllIIIIWIII —�Mechanical Rough Mechanical. Final G`�i ,��"i"".wb'Y �. e,s•�4.e7�' '�`v`}5n,�,�ly+.i2u�.st ;r>>grysrl-1=57i SG« ,�..�ir,'.cs�r9 rkn.�•.�Ynas _5t4 7., e•,..FI,r..?Sii r ttt .�'�. Gas Underground �-GasRough ._....�- CITY OF , SkNFORD Building & Fire Prevention Division RESIDENTIAL RE-R0OFAFFIDAVI7 FIRE DEPARTMENT RESIDENTIAL RE -ROOF INSPECTION AFFIDAVIT NAILING, SHEATHING, DRY -IN, FLASHING, AND ALL FINAL ROOF COVERINGS 4u1 PERMIT #: olb2" ADDRESS: 462p '�O SA0\, 5m4mro 17L 11y�+r , ", N , AS A(N) GENERAL, BUILDING, RESIDENTIAL, OR ROOFING CONTRACTOR, ENGINEER, ARCHITECT, OF F.S. CHAPTER 468 BUILDING INSPECTOR, I HEREBY AFFIRM, THAT ALL OF THE FOREGOING INFORMATION IS TRUE AND ACCURATE AND THAT ALL ROOFING COMPONENTS LISTED ON THE SCOPE OF WORK AT THE ABOVE REFERENCED ADDRESS HAVE BEEN INSTALLED IN ACCORDANCE WITH THEIR PRODUCT APPROVALS AND ALL APPLICABLE CODE REQUIREMENTS — SPECIFICALLY FLORIDA BUILDING CODE, EXISTING BUILDING. IN ADDITION I CERTIFY THE INSTALLATION MEETS ALL REQUIREMENTS FOR SECONDARY WATER BARRIER AND NAILING OF THE ROOF DECK, IN ACCORDANCE WITH THE HURRICANE RETROFIT MANUAL REQUIREMENTS (BASED ON F.S. CHAPTER 553.844). LICENSEA: COMPANY / CONTRA CONTRACTOR SIGNA (MUST BE SIGNED B Y CTOR: TU E: DATE: / 0 LICEN LDER UILDER) A FINAL ROOF INSPECTION IS REQUIRED: THIS SIGNED AND NOTARIZED AFFIDAVIT MUST BE PROVIDED AT THE JOB SITE AT THE TIME OF THE FINAL ROOF INSPECTION, ALONG WITH DIGITAL PHOTOGRAPHS OF EACH PLANE OF THE ROOF SHOWING IN DETAIL ALL COMPONENTS (DECKING, UNDERLAYMENT, FLASHING, DRIP EDGE ATTACHMENT) WITH THE PERMIT NUMBER OR ADDRESS CLEARLY MARKED ON THE DECK FOR EACH INSPECTION. THE PHOTOGRAPHS MUST INCLUDE A RULER OR MEASURING DEVICE TO CONFIRM ALL NAIL SPACING AND OVERLAPS, INCLUDING DRIP EDGE AND VALLEY FLASHING. PLEASE REFER TO THE RE -ROOF POLICY AND INSPECTION PROCEDURE PAPERWORK FOR FURTHER EXPLANATION OF ALL REQUIREMENTS. **FAILURE TO FOLLOW ALL REQUIREMENTS WILL RESULT IN A FAILED INSPECTION, A RE-INSPECTION'FEE AS WELL AS REQUIRING A DESIGN PROFESSIONAL (ARCHITECT OR ENGINEER) TO CERTIFY, BASED ON PERSONAL INSPECTION, THE INSTALLATION OF ALL ROOFING COMPONENTS. STATE OF FLORIDA COUNTY OF �eK dll� Sworn to and Subscribed before me this � day of r, 20 14' by: V/d / ,2 d." ,— Who is 1�ersonally Known to me or has ❑ Produced (type of identification) Signature of Notary Public State of Florida 1%,-a- Ca. (d cw e Print/Type/Stamp Name of Notary Public as identification. ............ VERA A CAD102121 .�..: Notary Public- S • : ( Commission >rMy Comm. ExpirHanded throughNat