Loading...
HomeMy WebLinkAbout524 San Lanta Cir (2).tea Job Address: 524 SAN LANTA CIR SANFORD, FL 32771 Parcel ID: 31-19-31-505-0000-1240 Type of Work: New ❑ Addition ❑ Alteration ❑ 7— 7 MAR 0 t�1� t CITY OF SANFORD MAR O ZO18 ` BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: % `g -0 Z-7 Documented Construction Value: $ 8,800 Historic District: Yes ❑ No Residential K Commercial ❑ Repair bg Demo ❑ Change of Use ❑ Move ❑ Description of Work: REPLACE 12 WINDOWS NON -IMPACT SIZE FOR SIZE. Plan Review Contact Person: Title: PERMIT MANAGER Phone: 954-7924415x243 Fax: 407-4728380 Email: permits@fhaproducts.com Property Owner Information G Name BUTLER, CHRISTOPHER Phone: �O� - 5710 ' q� � ` Street: 524 SAN LANTA CIR Resident of property? : OWNER City, State Zip: SANFORD, FL 32771 Contractor Information Name FLORIDA HOME -IMPROVEMENT ASSOC. Phone: 954-7924415 Street: 3044 SW 42 ST Fax: 407-4728380 City, State Zip: HOLLYWOOD, FL. 33312 State License No.: CGC061890 Architect/Engineer Information Name: N/A Phone: N/A Street: N/A Fax: N/A City, St, Zip: N/A E-mail: N/A Bonding Company: N/A Mortgage Lender: N/A Address: N/A Address: N/A WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property -that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies; or- federal agencies. Acceptanceof permit- is verificationthat.I will notify the owner of the.property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued,in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and. zoning. CA.- a-k 1?1 � M� ; Signature of Owner/Agent Date Signature o Date Arf-f 2,;J(_O Pritrt Owner/Agents Name � 0 tore of tale of Florida Date S00 t` ay PURL/0 * Go \Ss\ Owner/Agent is Personall; Kno Produced ID Type of 0�4rF oF'�' Name `\0go ��\G oeLO �\'` Q\1 : �a op" -State of Florida Date TE C3 ,QuaQc Go�\�` lca5\" o p" a• 0 Contractor/Agent is _ _ Perpnallynawn ttt Ade or Produced ID Type of fbr- °` Permits Required: Building❑ 'Electrical 0 -Mechanical ® Plumbing[] Gas[] Roof 0 Construction Type: Total Sq-Ft of -Bldg; Occupancy Use: Mn.-Occupancy Load: New Construction: Electric # of Amps ]Fire Sprinkler Permit: Yes 0 No ® # of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: FIRE: .Flood.Zone: # of Stories: Plumbing - # of Mitures Tire Alarm Permit: Yes[] 'No 0 WASTE WATER: BUILDING: S • tom Revised: June 3% 2015 Permit Application SCPA Parcel View: 31-19-31-505-0000-1240 Page 1 of 2 CFA Property Record Card P Parcel: 31-19-31-505-0000-1240 $EM7J0LtOWN" PLO Xo Property Address: 524 SAN LANTA CIR SANFORD, FL 32771 Value Summary 2018 Working Values 2017 Certified Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value Depreciated EXFT Value $74,234 $70,005 Land Value (Market) $15,000 $15,000 Land Value Ag Just/Market Value ** $89,234 $85,005 Portability Adj Save Our Homes Adj $17,553 $14,798 Amendment 1 Adj $0 P&G Adj $0 $0 Assessed Value $71,681 $70,207 Tax Amount without SOH: 2017 Tax Bill Amount Tax Estimator Save Our Homes Savings: Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund Schools _ $71,681 $46,681 $71,681 $25,000 $25,000 $46,681 g City Sanford ^� $71,681 $46,681 $25,000 SJWM(Saint Johns Water Management) County Bonds $71,681�� $46,681 I $71,681 _ $46,681 $25,000 $25,000 Description Date Book Page Amount Qualified Vac/Imp WARRANTY DEED WARRANTY DEED 7/1/2003 3/1/1980 104975 01273 10802 0796 $75,000 Yes I $30,100 Yes Improved Improved WARRANTY DEED � 3/1/1980 n _ 113 11 r _ 1445 .......E.._Hw.�..�.�.n- ! $301100 No mm� Improved Method Frontage Depth Units Units Price Land Value LOT 0.00 1 0,001 1 $15,000.00 I $15,000 IS bea/barn count Incorreci! DICK Here. # Description Year Built Fixtures Bed Bath Base Area Total SF Living SF Ext Wall Adj Value Repl Value Appendages Actual/Effective 1 SINGLE 1973 6 3 2_0 1,026 I 1,749 1 1,531 BRICK+WOOD $74,234 $97,676 Description Area I FAMILY E COMBO 180.00 http://parceldetail.scpafl.org/ParcelDetailInfo.aspx?PID=31193150500001240 2/9/2018 O, oil cmv ,, r r _m3 mur 'e<^A. �Ow ul% w ' �„a ,",, IWINM bdW rz r a WOMMA Aa Q 'm-2j F2A ft i 999 8 a. Win._..... s°. ZVI m� r % 9 r�GAR oil IF Y+sr 6» 3 w em F d ee '" #..:tom. L. °� . X'x.,.. ;,.mom.« ,.�.,.A.a »r �... '' xrx?`Comm- AR ec�4"=..7t,.,�Ffr.,:"�-«,ier>>, _^€€,s"a«a==4r�°-u"^"•'�.." .,,,.. v r 's�«.aA"V iY�; ¢r�r6 3 Md �Wu fi"x _mdCw_I=Iwot ON Most 5 LOA °iT. w wwanm3 Mac to na 0 fsmfaye W _7_ A THIS INSTRUMENT PREPARED BY: Name: BARBARA ESPARZA Address: FLORIDA OME IMPROVEMENT ASSOC. 8034 SUNPORT DR.1f401. ORLANDO, FL. 328 State of Florida County of Seminole Permit Number: ii UERI.'6 v 2Li18ii?3ii t i:.l. II1.IiCi Ii:l.:.'i d:i.t_trilif K_'': Parcel ID Number: 31-19-31-505-0000-1240 The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following Information is provided in this Notice of Commencement DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) LOT 124 SAN LANTA 3RD SECTS 13 PG 75 524 SAN LANTA CIR SANFORD FL 32771 GENERAL DESCRIPTION OF IMPROVEMENT: WINDOWS OWNER INFORMATION: Name: BUTLER, CHRISTOPHER Address: 524 SAN LANTA CIR SANFORD, FL 32771 Fee Simple Title Holder (if other than owner) Name. n/a Address: n/a CONTRACTOR: Name: FLORIDA HOME IMPROVEMENT ASSOC. Address: 3044 SW 42 ST. HOLLYWOOD, FL. 33312 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: n/a Address: n/a In addition to himself, Owner Designates Na of To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration -Date of Notice of Commencement (The errpWon date is i-year from date of recording unless a different date Is specified) WARNING W OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1,.SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY -BEFORE COMMENCINGWORK OR -RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that t have read the foregoing and that the facts stated in it are true to the "t of my knowledge and belief. Owrwes Signature Omars Prided Name Florida Stature 713.13(1xg): ' The owner must sign the notice of oanmencement arof no one else may be pa rnitted to sign In his or herstead' State of County of The fol oing in mine was acknowledged before me this Z 'b day of v , 26 �0, L e N by ! Y" l Who is personalty known to md' of person making atatement OR who has produced Identification ❑ type of identification produced: J 0,4�1 Paul Norman �PaYPVb Notary Public r Nalaryre�P 10 State of Florida � 9'-0 OF F`r � � My Commission Expires 3/10/2020 Commission No. FF 970481 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, bake Mary, Longwoo , Sanfor , Seminole County, Winter Springs Date: I hereby name and appoint: LUIS COLLAZO AND MERCEDES COLLAZO an agent of: FLORIDA HOME IMPROVEMENT ASSOC. (Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): IN The specific permit and application for work located at: 524 SAN LANTA CIR SANFORD FL 32771 (Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: WAYNE T. BURNETT State Licens Signature of STATE OF COUNTY C The f egoing instrument was acknowledged before me this 2 b day of FG,6 , 200 , by WAYNE T. BURNETT who i onally known to me or o who has produced as identification and who did (did not) take an oath. (Notary Seal) Paul Norman pY PV Notary Public 0�P State of Florida �9 OF F,Oo My Commission Expires 311012020 Commission No. FF 97WI (Rev. 08.12) q'611 0171411 Print or type name Notary Public - State of �G Commission No. My Commission Expires: /6 1711 io:roduct Approval ' pp! o Specification a m AML Permit # # 1 8- 1 1 2 7 sa�lFORo ARTM��� Project Location Address_ 524 San Lanta Cir, San or , FL 32771 As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # (include decimal) 1. Exterior Doors SANFORD B ILDI NIG DIVISION Swinging REVIEWED FOR CODE COMPLIANCE A PERMIT ISSUED SHALL BE ONSTRUED TO BE A Slidin LICENSE TO PROCEED WITH T 1E Sectional ASIDE ANY OF THE PROVISIO1 S OF THE TECHNICAL Roll U CODES, NOR SHALL THEREAFTER Automatic REQUIRING A CORRECTION OF ERRORS IN PLANS, Other 2. Windows Single Hung CWS 8100 FL4091.1 Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 , Category / Subcategory Manufacturer Product Description Florida Approval # (includin decimal) 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category/ Su6category Manufacturer Product Description Florida Approval # (include decimal) 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name WAYNE T. BURNETT (Please Print) June 2014 a firfi 1/4/2018 Florida Building Code Online ........... r !i � IIAwl 3 w st y ;.�3an q EMS Home ; Log In User Registration Hot Topics Submit Surcharge Slats &Facts Publications FBC Staff -I. BCIS Site Map Links- '', Search ��D1"IaG d, 41 Product. Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail E g/5 Y ,✓±F 3 3, FL k FL4091 RS Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352) 368-6922 Ext 245 kpine@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext221 amonteverde@cws.cc Category Windows Subcategory Singie Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lucas A. Turner the Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/2.1/2020 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL4091 R8 COI EvalReoort154F;odf Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440-05 2005 AAMA/WDMA/CSA/101/I.S 2/A440-08 2008 PA TAS 202 1994 Equivalence of Product Standards Certified By htto://www.floridabuildina.arci/or/or aoo dtl.asox?oaram=wGEVXQwtDquz931%2b4g5faHJ3x%2fpCz8Ew7OMgLld528M%3d 113 1/4/2018 Florida Building Code Online Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL 4091.1 Method 1 Option D 09/26/2017 09/29/2017 10/08/2017 12/12/2017 # Model, Number or Name Description - - -- . — - - - - - -- SH-8100 8100 Vinyl Flange/Fin Frame Single Hung - Installation Instructions Limf sofUse Approved for use in HVHZ: No j FL4091 R8 II CWS-1546pdf i Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +50/-50 Evaluation Reports Other: SH-8100, Max. size 53.125" x 76". Glass complies FL4091 R8 AE EvalReport154F.odf with ASTM E1300-04. Created by Independent Third Party: Yes I _. _ ...- .................... _._._.— - _ _ - - 4091.2 ( SH-8100 SH-8100 Vinyl Single Hung Non Impact. - Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL4091 R$ Ii CWS-485C.pdf Approved for use outside HVHZ: Yes i i Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Impact Resistant: No I Design Pressure: N/A Evaluation Reports Other: SH-8100 Vinyl Single Hung, OX, Max. size 52" x 71", FL4091 R8 AE EvalReport485C'.pdf see installation dwgs for DP. Glass complies with ASTM E1300 Created by Independent Third Party: ' Yes I 04. _......_ ................. ...-... - -- - - - 4091.3 --- SH-8100 Continuous Head & Sill I SH 8100 Vinyl Single Hung Continuous Head & Sill, Non I- Impact - -- - -- —�—_ _ - - -- Limits of Use Installation Instructions FL4091 R8 II CWS-442C.Ddf i Approved for use in HVHZ: No I Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: SH-8100 Cont. Hd. & Sill, Max. size 72 7/8" x 61 3/4", FL4091 R8 AE EvalRgport442C.pdf DP +67.5/-70 psf. Glass complies with ASTM E1300-04. 1 Created by Independent Third Party Yes - - _ .... .._.. T-_ _... —. __ .._ .. 4091.4 �SH-8100 Continuous Head & Sill SH 8100 Vinyl Single Hung Cont. Head & Sill, Non -Impact_ i of Use Installation Instructions !Limits I Approved for use in HVHZ: No FL4091 R8 II CWS-492C.Ddl 1 Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: SH-8100 Cont. Hd. & Sill, Max, size 74 1/8" x 72", see FL4091 R8 AE EvalRepor1:492C,ndf chart on installation dwgs. for DP. Glass complies with ASTM Created by Independent Third Party: Yes ; #E1300-04. { r4091.5 SH-8100 Oriel 8100 Vinyl Single Hung Oriel w/ HD Meet. Rail Limits of Installation Instructions Approved for use in HVHZ: No FL4091 R8 II CWS-293D.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +60/-60 Evaluation Reports Other: SH-8100, Max. size S2" x 96", Oriel. Glass complies 1 FL4091 R8 AE EvalReport293D.tidf with ASTM E1300-04. 1 Created by Independent Third Party: Yes J Contact Us 2601 Blair Stone Road Tallahassee FL 32399 Phone, 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida. law, email addresses are public records. If you do not want your e-mail address released inresponseto a public -records request, do not send electronic mail to .this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. `Pursuant to Section htirl•/lwww.flnridahuildino.ora/Dr/or aoD dti.asox?param=wGEVXQwtDquz931%2b4g5faHJ3x%2fpCz8Ew7OMgLld528M%3d 2/3 1/4/2018 Florida Building Code Online 455.275(1),. Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. mustprovide the Department with an email address if they have one. The emails provided maybe used for officialcommunication with the licensee, However email addresses arepublic record. if you do not wish to supply a -personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe httD://www.floridabuildina.ora/or/i)r apo dtl.aspx?param=wGEVXQwtDquz931%2b4g5faHJ3x%2fpCz8Ew7OMgLld528M%3d 3/3 RNER1 V , ENGINEERING & CONSULTING, INC. 1.239 Jabara Ave. r North PortAFL _34288 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report 154F August 28, 2017 Product Description: Series 8100 PVC Single Hung Window, Non Impact, 53 1/8" x 76" unit size, 54 3/8" x 77 1 /4" flange size Manufacturer: Custom Window Systems, Inc. 1900 SW 44"' Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements of the 6t" Edition (2017) Florida Building Code outside the High Velocity Hurricane Zone. The product testing standards performedare outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-154F, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3809-1 and -1A, from. National Certified Testing Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E. a. Testing Performed: AAMA/WDMA/CSA 101/l.S.2/A440-08 4) Supplemental Calculations to support CWS-154F, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-154F. Limitations of Use: This product: ® May be used in the configurations and sizes and with daylight openings as indicated in CWS-154F ® Achieves design pressures as indicated in comparative analysis table in CWS-154F • Is non -impact and requires the use of shutters in windborne debris regions • May not be used in the High Velocity Hurricane Zone • Requires glass as shown in CWS-I54F ® Requires Quanex (Mikron) white rigid PVC extrusions as shown in CWS-I54F Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in. Custom Window Systems or in any comlaany manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. trr�t�t. `"NJ%tiiltLucas 41 . - ` 1• No 582201' ' 8/28/20.175 Turner ` ` = * f Lucas A. Turner, P.E. 2017-08-30 ,� 15:58+20:00•, = FL PE #58201. STATE Or w A'_ SINGLE HUNG - NON -IMPACT (SHOWN W/DIFFERENT OPTIONS) 54 318" MAX OVERALL 54 3f—^" FLANGE WIDTH MAX OVERALL 531/8' --� FLANGE WIDTH MAX. UNIT WIDTH 48 1 -MAX. UNIT WIDTH GLASS DLO `t A GLASS DLO T I 33 5116" 69 1/2' O I I GLASS MAX DLO OVERALL 33 5/16' B B FLANGE O GLASS HEIGHT DLO .I-- 1 §8 I HT MAX UNIT � f 3611116" + HEIGHT MAX. SASH /� I 33 5 GLASS 3�A3/Y16 �/ X 26 7/8" HEIGHT n I DLO SASH A GLASS A A i C 6 � 465116" ---i r— 465/16" GLASS DLO GLASS DLO EQUAL SPLIT 5 HI SASH ORIEL `_— 54 3/6" MAX OVERALL FLANGE W IDTH 53 1{8' MAX. UNIT WIDTH r- 48 15116" GLASS DLO�� 63 5/16" 1 MAX OVERALL 133 5/16' FLANGE O GLASS HEIGHT DLO 62 1116" MAX UNIT —r HEIGHT 24" 2011116' SASH X GL11 ASS E-- 46 5116' --! GLASS OLO 60/40 SPLIT ORIEL TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS....,1 DP CHARTS & GLAZING DETAIL........2 SECTION VIEWS& ALT, FRAME EXTRUSIONS & B.O.M........................A ANCHOR SCHEDULE & NOTES .......... 5. INSTALLATION DETAILS.....................6. GENERAL NOTES: //'S799®08- t IWINDOW 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED SYSTEMS TO COMPLY WITH THE FLORIDA BUILDING CODE (FBQ. CURRENT EDITION. 1900 SW 44TH AVE. OCALA, FLORIDA 34474 2, GLAZING OPTIONS:. (SEE SHEET 2) W W W.CWS'.CC 3. CONFIGURATIONS: "O/X". 8100 PVC 4, DESIGN PRESSURE RATING (SEE SHEET 2): SINGLE HUNG NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. NON -IMPACT -POSITIVE. DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS. TABLES ASTM E-1300-04e01/09. < z `t 5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED z w -0 w , 0 < w z x z I, - IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR ° z 0 R 3 §.z DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD w Q ANCHOR. CALCULATIONS, Z z= m`< x W p O 0 0f-06<x,w 6. NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE p 0 co� z z F j CL SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION. 7� O Z U� z.co U 7. ALL FRAMES AND VENTS FULLY WELDED, SMALL JOINT SEAM SEALANT }' U < y O.w O Oi O z L) USED AT FIXED MEETING RAIL AND JAMB. < - p F 10 w OT (0011jow 8. SERIES / MODEL DESIGNATION SH-8100. a z = w 0: O _ � 9..THE DESIGNATION X AND O STAND FOR THE FOLLOWING: p r-0. �>- wax x w m w ~ a C X= OPERABLE SASH, O= FIXED SASH a a 10. ALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR Etv uREt.. LOCATION, ,`}�`P............ E N 11, EXTERNAL WEEP SLOT= 1/2" x 2-1/2" LOCATED 4" FROM BOTH ENDS. N- 58201 P : STATE OF 0 ",TF,F40R Lucas qr..\�.�� G. Turner %SS.ONP.� 2017-08-30 17:10+20:00 CONFIG. MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING EQUAL 53-1/8" x 76" SEE COMPARATIVE ANALYSIS CHART, SHEET 2 NONE 5 HI ORIEL 53-1/8" x 68-1/4" NONE 60/40 ORIEL 53-1/8" x 62-1/16" NONE `� 8/28/2017 LUCAS A, TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941.380-1574 GENERAL NOTES AND ELEVATIONS BAT 04/29/08 VG G: REV.: CWS-154 F :ALE: SHEET 1:33.33 1 OF 6 i, Design Pressures (PSF) with Glass Types A, B, C, Or Unit Sash Unit Widths (in.) Heights (in.) Heights (in.) 23 1/2 27 1/2 29 1/2 31 1/2 1 35 1/2 39 1/2 41 1/2 43 1/2 47 1/2 51 1/2 53 1/8 35 1/2 17 +50 / -75 +50 / -75 +SO / -75 +50 / -75 1 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 39 1/2 19 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50/ -75 41 1/2 20 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -73.1 43 1/2 21 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -73 A +50 / -70.6 47 1/2 23 +50 / -75 +50 / -75 +SO / -75 +50 / -75 +50 / -75 1 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -68.9 +50 / -66.2 51 1/2 25 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -72.7 +SO / -65.2 +50 / -62.6 53 1/2 26 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50 / -71 +50 / -63.6 +50 / -61 55 1/2 27 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-69.5 +50/-62.1 +50/-59.5 59 1/2 29 +50 / -75. +50 / -75 +50 / -75 +50/ -75 +50 / -75 +50 / -75 +50 / -75 +50 / -75 +50/ -66.8 +50 / -59.5 +50 / -57 63 1/2 31 +50/-75 +50/-72.9 +50/-72 +50/-71.6 +50/-71.6 +50/-71.6 +50/-71.6 +50/-71.6 +50/-64.6 +50/-57.3 +50/-54.8 65 1/2 32 +50/ -73.2 +50 / -69.1 +50 / -68 +50 / -67.4 +50 / -67.3 +50 / -67.3 +50 / -67.3 +50 / -67.3 +50 / -63.6 +50 / -56.4 +50 / -53.9 67 1/2 33 +50 / -69.8 +50 / -65.6 +50 / -64.4 +50 / -63.7 +50 / -63.4 +50 / -63.4 +50 / -63.4 +50/ -63.4 +50 / -62.7 +50 / -55.5 +50 / -53 71 1/2 35 +50 / -64 +50 / -59.7 +50 / -58.3 +50 / -57.3 +50 / -56.5 +50 / -56.5 +50 / -56.5 +50 / -56.5 +50 / -56.5 +50 / -53.9 +50 / -51.5 74 3/4 36 5/8 +50/-59.9 +50/-55.6 +50/-S4.1 +50/-53 +50/-51.8 +50/-51.7 +50/-51.7 +50/-51.7 +50/-51.7 +50/-51.7 + 76 37 1/4 +50 / -58.5 +50 / -54.1 +50 / -52.6 +50 / -51.5 +50 / -50.2 +50 / -50 +50 / - SO +50 / -50 +50 /-50 +50 / -50 +50 / -50 7/8" OVERALL 718" OVERALL 7/8' OVERALL-i-7/8' OVERALL 116" ANNEALED - �3116" ANNEALED �" +-118" TEMPERED - 3116' TEMPERED 518" AIR SPACE 112" AIRSPACE 5/8" AIR SPACE 12- AIRSPACE 118" ANNEALED �3/16" ANNEALED 118" TEMPERED - i -3/16" TEMPERED SIKAFLEX 552 OR I SIKAFLEX 552 OR SIKAFLEX 552 OR SIKAFLEX 552 OR PURFECT GLAZE"H' 46 PURFECT GLAZE"H" 46 PURFECT GLAZE'H' 46 PURFECT GLAZE"H" VF'f2 GLASS BITE j t/2' GLASS BITE I "� 112" GLASS BITE I 1!2" GLASS BITE GLASS TYPE A NOTE: IF SIZE INTENDED IS NOT SHOWN, USE NEXT LARGER SIZE. GLASS TYPE B GLASS TYPE C L GLASS TYPE D gum' WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA. 34474 1NWIN,CWS.CC 8100 PVC j SINGLE HUNG NON -IMPACT a z 3 ¢z3 z WJQ <-,wo w zOz Crt_t 0 z c03>-OD=�m u 1-w. ZF-3m= O OII--,.0Z6<mOD U UtnF'a�u~ia z oo:) � n zoozo V -u20 Z < KKK}230N W O�WNpwcoW Ft zco n p w'0 ax02� D: w n n w�0 OREw/T r ENgt�L'A'1�� 'w No 58201 • F� 3,% STATE OF :40z ',,S70NA 4"'��� ly_ '�:n 8/28/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PART, FL 34288 PH. 941-380-1574 SHEET DESCRIPTION: COMPARATIVE ANALYSIS AND GLAZING DETAILS DRA:NN BY: DATE: BAT 04/29/08 DWG#: REV.: CWS-154 F SHEET t:1 20F6 INTERIOR 900 WIN�44TH SYSTEAVEMS OCALA. FLORIDA 34474 www.cws.cc- i a5 32 _ 54 12 3 13 35 32® 45 T 8100 PVC SINGLE HUNG Lo NON -IMPACT 45' Q Z a Z 3 owp ¢moo z a�3>o�3m u. i4 331 � Z Z=iQ�wpp t5 53 1� 65 6E �6�19 L4 O OF-O�ja=ram SECTION B-B p Z`noZZFaw 53— NOTE: LEFT SIDE SHOWS FIXED SECTION VIEW, < a �-O OD z RIGHT SIDE SHOWS SASH SECTION VIEW. w 00DLL i w ZTww p�u, � 14 ` 39 _~� wO. L.0 40 2 a �3a 7 8 71 �'� INTERIOR `�� `� pE7a No 58201 STATE- OF :�4'` 29 SS�ONAL- 1s 46� z Z `o S/2S/2017 3 t8 3 _ LUCAS A. TURNER, P,E. " 3'J FL PE # 56201 G D 1239 JABARA AVE, 30 NORTH PORT, FL 3428E 405 PH. 94.1--380-1574 a SECTION C'.-C SHEET DESCRIPTION: ALTERNATEFIN FRAME SECTION A -A SECTION VIEWS DRAWN BY: DATE: BAT 04/29/08 DWGq: REV.: NOTE: ITEMS NOT SHOWN FOR CLARITY: CWS-154 F 20, 23. 25-26, 31, 36, 37, 44, 51=52, 55-56,.64, 67-68 SCALE: SHEET 1:2 3 OF 6 i, w/Flg.. PVC, Sill Nlikmn Vinyl i I _ 3Ins 9116" O I t PVC FRAME FIN H-6026 `' 3116"-j IKH_6031 , w/Fig., PVC, L. Jb, Mikron Viny l i, Fig., PVC, R. Jb. Mikron Vinyl =xd. Keymark Alum Rail, PVC. Mikron Vinyl Meet. Rail Keymark Alum n Rail, PVC Mikron Vinyl op/Bot. Rail Mikron Vinyl :./S.S.R Keymark Alum 3",Fxd., Horiz. Mikron Vinyl 3",Fxd., Vert. Mikron Vinyl 3",Sash, Horiz. Mikron Vinyl 3",Sash, Vert. Mikron Vinyl ., w/Nib, PVC, Horiz. Mikron Vinyl ., PVC, Vert. Mikron Vinyl Filler, PVC, Vert. -Mikron Vinyl BSIPVC BSI PlasticPd, SSact, PVC Interlolck PVC Interlock l Zamac,w/ Flap Geer Plastic 0 x .187 back FinSeal, Gray Ullrafab 0 x .187 back: FinSeal, Gray Ultrafab 0 x .187 back-FinSeal, Gray Ultrafab N Y=3/btl A0XU"""'"`"'""J nuu l.ity .� , 39 P�4051W #8 x 1-.250 Ph FHTEK, -Whl. Hub City Steel 40 P-4264 1#8 x 3M FH PH w/#6 Head, TEK,. Wht Hub City Steel 44 1 P-3342 ISeam Sealer, SM-5504 i Schnee 46 P3436 SiKatleX JbG or runect Ulaze rr aiKamenKei 48 1-3 2 Set. Blk., 85 Our., 1/B" x 5/8" z 2" Lg, F. Lowe Rubber 51 P-3681 ITemporary LN.(NFRC/DP) 52 1 P-3613 ICWS Lbl. (logo) Pro Label k 5116"---t 109 l— 1116• PVC SCREEN SUPPORT S-6014 i g 1' REINF. SASH MTG. RAIL H-1497 �f5/16"--{ 1 5I16" PVC SASH BTM. RAIL H-6028 1 3116` 1ft6' t PVC SASH SIDE RAIL H-6004 111�� ,2" F 18 L /is" PVC SCREEN CATCH S-6013 3I76' 13 1116" REINF. SBR/SSR S-1498 67 j P3029 IScreen Pull Tab Summit Alum 1/2' N P-3033 Screen Spring, SS 69 H302b Main Fr., SH, w/Fin., PVC FI. Screen Mikron SS Vinyl 3116"1 I 3"---� 70 1 P-3113 IScrew Support for PVC T. Plastics Nylon _ T-� 71 S-6063 Fixed. Rail Cover Mikron Vinyl SCREW SUPPORT P-3113 LINE ITEMS NOT USED: NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 6-7, 11, 21-23. 29, 31. 41-43. 47, 49-50, 57-61 777--- (-- 2 3116" — i � B 1 516" 1116' i PVC SASH MTG. RAIL H-6027 Ft 1/2` i 05, IJ 2 1/8" - — 1/16- {I 1I6" FIXED MTG. RAIL H-1836 i..-_ -_13116' L irt6' PVC SASH STOP S-6029 v4" — r '�� 14 7/8" 7 L_ 16 1 PVC GLAZING BEAD S-6064 9/16` T_ V PVC FIXED RAIL COVER S-6063 FRAME CORNER CONSTRUCTION CORNER WELD (ALL SIDES) 1:8 37 FIXED MEETING RAIL SCREWED TOGETHER WITH OUTERFRAME 1:6 05010M. WINDOW SYSTEMS 1900 SW 44Dh AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8100 PVC SINGLE HUNG NON -IMPACT Qzo F- pW0 <Wzw z uj�oz0z Qtzw o ;wcW;i>-0M3:E z zi�a�3'zx O O1- <x'M c� 0wF-z0_' g_ oI z—'U) n QpWO=0Z W 00 w>-0w O w U`0w 0 O-,m f- If ` JVPS.��GE1Jg� G"Q2� i No 582D1 :1 = O: TAT E F ,ice S/28/2017 I LUCASA. TURNER, P.E. FL PE # 58201 1239JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 BOM AND EXTRUSIONS BAT 04/29/08 VG n: REv.: CWS-154 F ALE: SHEET 1:8 4OF6, j?" MAX.O.0 6' MAX. (TYF 6" MAX. (TYF IQ: MAX. O.C. (TYP.) 4- (TYP) 4- (TYP) ANCHORLAYOUT- (FLANGE) 0TE 2 4" MAX. (TYP) 4- MAX. (TYP.) >TE 2 WINDOW SYSTEMS L 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8100 PVC SINGLE HUNG e" NON -IMPACT MAX O.C. O (TYP.) z �: ¢z� INSTALLATION Z -W � Q Q k Z Q THRU FRAME ANCHOR ANCHORS TYP. w Z O 2'-- W — — H MEETING RAIL AT FIXED MEETING RAIL 0 Q. co� >.O CC � m CENTERLINE (TYP.) Z Z= g Q K 3 E _' O O r 0 ¢ _ � Z: U 00n -Z0- O Z— U)— Z F O y X Z O_ O O U— F-Z.O VLL�pOw,z NSTALLATION cr 2. Q O F- ANCHORS TYP. /X ccF} j 3 O 2 lT w uZ O_ 00 U)i � a ANCHOR LAYOUT - (FIN) NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS. HEAD. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS, MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED, 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS. SEE TABLE 1, SHEET 6. C.Pc'SAG Eli No 58201'�� STATE OF :'W 'z'7__' 8/28/2017 LUCAS A. TURNER, RE. 4. ALL INSTALLATION ANCHORS MUST BE. MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 1239 Al 39 JABARA RA AVE. 5, INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT, FL 34288 PH. 941-380-1574 SPECIFIED IN TABLE 1. SHEET 6. SHEET DESCRIPTION: 6, ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE - 1X BUCKS ARE ANCHOR SCHEDULE At OPTIONAL. NOTES 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1' FOR WOOD AND METAL. oRAwN ev: 8. WOOD OR MASONRY OPENINGS', BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. BAT �.ATE; 04/29/08 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. GWG#: REV.: 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: I CWS-154 F FIANAAMA 100(FIN WINDOWS). FMA/AAMA200(FLANGE. WINDOWS), FMA/WDMA250(BOXWINDOWS),FMAIAAMA°NDMA300(EXTERIOR DOORS) SCALE` .SHEET 1`:25 5 OF 6 MIN. EMBEDMENT i / ( ?•I /7CN77�fTSN)'L/�{/� TYPICAL HEAD ANCHORAGE SEE TABLE 1 SUBSTRATE �Llib(1'dvCY UUC% f�l ��/jl� I� BY OTHERS WINDOW✓ SYSTEMS MIN, EDGE DIST. 1/4' MAX SHIM --I SEE TABLE 1 MIN. EDGE DIST. — SUBSTRATE —,—SEE TABLE t - SEE TABLE 1 BY OTHERS OCA A, FLORIDA AVE. I 114" MAX. SHIM SEE TABLE i wWW. WS.CC 34474 � SUBSTRATE BY OTHERS-� � I � WWW.CWS.CC SEE TABLE 1 1� o MIN. EDGE DIST, MIN. EMBEDMENT SEE TABLET SEE TABLET PERIMETERSEALANT1- 8100 PVC BY INSTALLER j INSTALLATION ANCHOR - INS IDEAND OUT SEE TABLE I SINGLE HUNG SEALANT BEHIND T MIN. EMBEDMENT FLANGE BY INSTALLER 1!4" MAX. SHIM ( SEE TABLE 1 NON -IMPACT PERIMETER SEALANT Z o J o Q I W- 121 W LSEAILANT PERIMETER SEALANT nBYINSTALLER w ZOZ (r- BY INSTALLER .mINSIDE AND OUT 0 HW 3 ZO��SINSIDE.AND OUT INSTALLATION ANCHOR Z Z=M6OfW00 BEHIND SEE TABLE 1 O O 1- 0,3 Q.= ♦- INSTALLATION ANCHOR FLANGE BY INSTALLER SEALANT BEHIND 0 O In N Z d ~ In (- SEE TABLE 1 FIN BY INSTALLER Z z C7 0_ Z I-- U N g HORIZONTAL SECTION C_ HORIZONTAL SECTION: Q 1• Z u g O 0 u 0 6 TYPICAL JAMB ANCHORAGE TYPICAL FIN ANCHORAGE ry 3 O I= I=- Z Z HEAD AND SILL SIMILAR FOR FIN INSTALLATION � } L) 3: O SEALANT BEHIND - FLANGE BY INSTALLER PERIMETER SEALANT - BYINSTALLER INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1 114' MAX. SHIM MIN. EMBED! SEE TABLE 1 —MIN. EDGE DIST. SEE TABLE 1 SECTION. SILL ANCHORAGE TABLE 1: APPROVED INSTALLATION FASTENERS FRAME TYPE SUBSTRATE. TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. FLANGE CONCRETE (2.0 KSI MIN.) 3/16' ITW TAPCON 1" 1-1/8" FLANGE 2„ NGE CONCRETE (2.85 KSI MIN.) 3116" ELCO ULTRACON 7" 1" FLANGE GHITIT - FLANGE 2XMIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON 1-3/8" 7/8" OR ELCO ULTRACON FLANGE 12XMIN. SOUTHERN PINE(G=0.55) 10 WOOD SCREW 1.3/8" 7/8" 16 GAUGE (0.0(30") MIN. STEEL STUD !t10-1fi HILTI KW IK-FLEX OR ITW FULL THREAD 7/16" FLANGE (33 KSI YIELD MIN) TEKS SELF -DRILLING SCREW THRU 0.060" 1/8 ALUM. (6063-T5 MIN.) OR 910 GRADE 5 SELF -TAPPING / FULL THREAD 7/16' FLANGE 1/8".STEEL (33 KSI MIN.) DRILLING SCREW THRU 0.125" FIN 2XMIN, SOUTHERN PINE (G=0.55) 1910 WOOD SCREW 1-1/2" 1/2' W Ft 0u0 W0Q�U H 0 w a0 aOx2> a X a r3a"' N o 58201 .9 — �O•. STATE OF :•u/� t y O 9/28/2017 LUCAS A. TURNER, P.E. FL PE # 58201 PERIMETER SEALANT--- 1239 JABARA AVE. BY INSTALLER NORTH PORT, FL 34288 INSIDE AND OUT HORIZONTAL SECTION PH. 941-380-1574 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: SIMILAR FOR SILL AND JAMBS FOR BOX INSTALLATION INSTALLATION DETAILS FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED: DRAWN BY: DATE: BAT 04/29/08 - PAIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED DWGS: REV.: - INSIDE AND OUT, FULL PERIMETER, BY INSTALLER. CWS-154 ` F PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SHOWN FOR FLANGE WINDOWS. SCALE: SHEET 12 6OF6