HomeMy WebLinkAbout103 Ventura Dr (2)e
CITY OF SANFORD
C� BUILDING & FIRE PREVENTION
PERMIT APPLICATION
Application No: 1 - 9_y,D_1
Documented Construction Value: $ 1337.85
Job Address: 103 VENTORA DRIVE SANFORD, FL 32773 Historic District: Yes ❑ No ❑
Parcel ID: 10-20-30-503-0400-0860 Residential 0 Commercial ❑
Type of Work: New ❑ Addition ❑ Alteration ❑ Repair 0 Demo ❑ Change of Use ❑ Move ❑
Description of Work: REPLACE EXISTING GARAGE DOOR SIZE FOR SIZE
Plan Review Contact Person: CHARLES MERINO 'Title: INSTALL MANAGER
Phone: 321-284-8290
Fax: 877-225-0658 Email: CMERINO@PRECISIONDOOR.NET
Property Owner Information
Name THOMPSON, JANINE & PETER
Street: 103 VENTURA DR
City, State Zip:
SANFORD, FL 32773
Name WILLIAM WALDEN
Street: 244 OBRIEN RD
City, State Zip: FERN PARK FL 32730
Name:
Street:
City, St, Zip:
Bonding Company:
Address:
Phone: 407-701-9371
Resident of property? : YES
Contractor Information
Phone: 321-284-8290
Fax: 877-225-0658
State License No.: CRC1330671
Architect/Engineer Information
Phone:
Fax:
E-mail:
Mortgage Lender:
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application: and the code in effect as of that date: 5t' Edition (2014) Florida Building Code
Revised: June 30, 2015 Permit Application
i
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ]CC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
Signature of Owne Agent Date Signature of Contractor/Agent Date
P Tl�
Y J� h, v07 WILLIAM WALDEN
Print Owner/Agent's Name Print Contractor/ ent's me
7 _
Signature of Not da Date Signatu p idA -Stat �� ate
L398-0163_
'' Mrs ,: sE. ��r�THv 1:S1NG MYCOMMISSION u FF940MY COMMI •4 SSION # FF993'5q EXPIFZESDecember 01,EXPIRES May 18, 2020 OLIO398-0-.53P�ordallot2019
rySeriicacem
F�oriWNae Sen�cB.opn
Owner/Agent is Personal Known to e or Contractor/Agent is X Personally Known to Me or
Produced ID pe of IDS L- Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas❑ Roof ❑
Construction Type:
Total Sq Ft of Bldg:
Occupancy Use:
Min. Occupancy Load:
New Construction: Electric - # of Amps
Fire Sprinkler Permit: Yes ❑ No ❑
APPROVALS: ZONING:
ENGINEERING:
COMMENTS:
# of Heads
UTILITIES:
FIRE:
Flood Zone:
# of Stories:
Plumbing - # of Fixtures
Fire Alarm Permit: Yes ❑ No ❑
WASTE WATER:
BUILDING: 'IC76-(4• It
Revised: June 30, 2015 Permit Application
REQUIRED HgSIPECTI.ON SEQUENCE
npa F-)— n _r',l-7
B'><jm, , DING 1 Bptmr
Min ID@sctrIl ttll®n.
Footer / Setback
Stemwall
Foundation / Form Board Survey
Slab / Mono Slab Prepour
Lintel / Tie Beam / Fill / Down Cell
Sheathing — Walls
Sheathing-- Roof
Roof Dry In
Frame
Insulation Rough In
Firewall Screw Pattern
Drywall / Sheetrock
Lath Inspection
Final Solar
Final Roof
Final Stucco / Siding
Insulation Final
Final Utility Building
Final Door
Final Window
Final Screen.Room
Final. Pool Screen Enclosure
Mobile Home Building Final
Pre -Demo
Final Demo
Final Single Family Residence
Final. Building Other
Addr@ss-
��:6'DSll�� IPrlE9�rll1L
Min Max. Ins @c tion Descri¶D1rllon
.�
Electric. Underground
Footer / Slab Steel Bond
Electric Rough
T.U.G.
Pre -Power Final
Electric Final
.;..e�
'.,.,.�d�'-k'.�dn'FY&'�4Ir�`NA.� '�.�..`1.iy�a .V+4; e� N'h":tl'hYli��. ��.,:*'Y�^`•
Max Inspection Descri2flon
Min
Plumbing Underground
Plumbing Sewer
Plumbing Tub Set
Plumbing Final
Min Mays
llns @@tion ](Descri]fion
Mechanical Rough
Mechanical Final,
Min
Mast
Ins @@ttion. Descri�ttion
Gas Underground
Gas Rough
Gas Final
REVISED: June 2014
Billing Address
Peter Thompson
103 Ventura Drive
Sanford, FL 32773 USA
Precision Door Service of Central Florida Invoice 45745934
244O'Brien Rd Invoice Date 5/21/2018
Fern Park, FL 32730 Completed Date
877-225-0658
Customer PO
Description of Work
Job Address
Peter Thompson
103 Ventura Drive
Sanford, FL 32773 USA
Task #
Description
Quantity Your Price Your Total
42511
12 inch Radius Track
1.00
$0.00
$0.00
159179
8x7 Garage Door - Haas door
1.00
$938.00
$938.00
42518
Lifetime Warranty on Hardware
1.00
$0.00
$0.00
42515
Lifetime Warranty on Paint Finish
1.00
$0.00
$0.00
41620
Short Panel Design
1.00
$0.00
$0.00
143438
New Door Vinyl Trim Kit for Single Car Garage Door: Includes (1) Horizontal piece and
1.00
$59.95
$59.95
(2) Vertical pieces
143432
8' 2x4 Pressure Treated Header
1.00
$59.95
$59.95
156052
$150 off New Garage Door
1.00
$-150.00
$-150.00
109269
Senior Citizen/Military 5% off total invoice *Website*
1.00
$-70.00
$-70.00
41620
Short Panel Design
1.00
$0.00
$0.00
41762
Dark Brown Color
1.00
$0.00
$0.00
130290
Seminole County: Door Permit
1.00
$100.00
$100.00
45213
Linear LDO50 Chain Driven Garage Door Opener: 1/2 HP AC Motor with 1 remote,
1.00
$449.95
$449.95
wall control and safety sensors
151293
$50 off Any New Garage Door Opener
1.00
$-50.00
$-50.00
8159199
Haas 100 Non Insulated: Heavy-duty 24 Gauge Exterior Steel - Durable, Reliable, Low
1.00
$0.00
$0.00
Maintenance
Paid On Type Memo Amount
5/21/2018 Discover $150.00
Sub -Total $1,337.85
Tax $0.00
Total Due $1,337.85
Payment $150.00
Balance Due $1,187.85
Contractor Number: CRC1330671
I authorize Precision Door Service of Central Florida to perform an initial door/service or repair estimate which will be presented to me
in writing.
I acknowledge that an initial door/service or repair estimate was performed on and presented to me in writing and sent by e-mail.
I authorize Precision Door Service of Central Florida to charge the agreed amount to my credit card provided herein. I agree that I will
pay for this purchase in accordance with the issuing bank cardholder agreement.
5/21/2018
5/22/2018
SCPA Parcel View: 10-20-30-503-0400-0860
Legal Description
LOT 86 BILK 4
HIDDEN LAKE PHASE II UNIT I
PB 24 PGS 15 TO 17
1............ _... .... .......
.__-�..�..__..._.__.�_._.._____.-_
Taxes
Property Record Card
Parcel; 10-20-30-503-0400-0860
Property Address; 103 VENTURA DR SANFORD, FL 32771
Value Summary
Taxing Authority
Assessment Value
Exempt Values Taxable Value
-_...._......._,..._...._.__..-._..._.__..____._...................__._..._.__....____....__.__.....___..,.....,..........._...._.___..___..__....._
County General Fund
._.......... _---__....__.___.._..V.........--........._.___._._......._._.
(
_._.;_.......................__.._....._..._._......_......................__..._._.....__;..__.._.___.........................._...._........_......_._._...................,
$70 229
$45 229 ,
$25,000
Schools
i
$70,229 !
$25 000 :
$45,229
City Sanford
$70 229
$45 229
$25 000
SJWM(Salnt Johns Water Management)
$70 229.
$45 229
$25V000
County Bonds
........_._._....._._._._.._..._.._.....__..__---.._._._._.W...._...._.._.._._-........_..-.-.._....._...-._._._..._.
$70,229
_....._..._......__.....-___________
$45 229
......_._____...__ ___ _...
$25 000 i
......... ..
Sales
...
r
I Description
Book Page
Amount
Qualified Vac/Imp
�JDate
QUIT CLAIM DEED 5/1/1996
�' 03071 1448
mm
$24,100 No Improved
j QUIT CLAIM DEED 6/1/1992
02610 1204
$23,100 No Improved
.... .................. ....
i... ...........
WARRANTY DEED 1/1/1981
? 01315 1200
—
_ _.. ...............
!
$41,400 Yes Improved
......._..._..__............_.......... _
!i
........_......................... ..... -._..__._
Land
.....
.....
Method E Frontage
_ .....
Depth
Units
Units PriceLand
Value
LOT 0.00
0.00
1
$30,000.00
$30,000
.., .-,__.._................
Building Information
..... ..� ......_...,_,..-F_ , ..........
._._._,....,,.,,� ..........,,.,., .,
i
i Is Bed Bath count incorrect? Click Here
# Description Year Built Fixtures Bed
i
Bath st Base Area ` Total SF Living
SF Ext Wall
' Ad1 Value Repl Value Appendages
;
http://parceldetail.scpafl.org/Parcel Detail I nfo.aspx?PI
D=10203050304000860
1 /2
LIMITED POWER OF ATTORNEY
Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford,
Seminole County, Winter Springs
Date: 05/22/18
I hereby name and appoint: Thomas Beesing
an agent of:
Precision Door Service
(Name of Company)
to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things
necessary to this appointment for (check only one option):
® The specific permit and application for work located at:
103 VENTURA DRIVE SANFORD, FL 32771
(Street Address)
Expiration Date for This Limited Power of Attorney: N/A
License Holder Name: William Walden
State License Number: CRC1330671 11�
Signature of License Holder: (,(,�I"� �/ ofl
STATE OF FLORIDA
COUNTY OF Seminole
The foregoing instrument was acknowledged before me this 22 day of MAY ,
200 18, by William Walden who is iXpersonally known
to me or ❑ who has produced as
identification and who did (did not) take an o �.—.
Signature
(Notary Seal)
Print or type name
Notary Public - State of Florida
Commission No.
My Commission Expires:
(Rev. 08.12)
CHARLES E. DER!
tiPy,V G RAY COMMISSION # FrF9
December 01.
FlocdallotpN wica.ccr
i4Cll3�e-0t53
E�398-O'53
"IARLES C. MERII�®
COMMISSION #i FF940114
PFRES December 01, 2019
r10r1daN0tnService.c0rr
D18
. ,
parceldetail.scpafl.org/FootprintPage.aspx?PID=10203050304000860&BLDGNO=1 &PAGENO=1
Parcel: 10-20-30-503-0400-0860 Building No.: 1 Page No: 1
RECU UP
16
SPU 10
160'sf
8.
40 13
BASE 26, GRF I
1040 s# 338 s#
REVIEWED FOR CODE COMPLIANCE
PLANS EXAMINER
DATE
OPF 13
4 88 0
22
Sketch by Apem Sketch
SANFORD BUILDING DIVISION
A PERMIT ISSUED SHALL BE CONSTRUED TO BE A
LICENSE TO PROCEED WITH THE WORK AND NOT AS
AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET
ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL
CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT
THE BUILDING OFFICIAL FROM THEREAFTER
REQUIRING A CORRECTION OF ERRORS IN PLANS,
CONSTRUCTION OR VIOLATIONS OF THIS CODE
e
1 8- 2 i 7
+y
http://parceldetail.scpafl.org/FootprintPage.aspx?PID=l0203050304000860&BLDGN0=1 &PAGEN0=1 1 /1
4
€a w J13
y
City of Sanford
Building and Fire Prevention
Product Approval Specification Form
Permit #.
Project Location Address 103 VENTURA DRIVE, SANFORD, FL 32773
As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the
information and product approval number(s) on the building components listed below if they are to be
utilized on the construction project for which you are applying for a building permit. We recommend that
you contact your local product supplier should you not know the product approval number for any of the
applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in
accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product
Approval can be obtained at www.floridabuilding.org.
The following information must be available on the jobsite for inspections:
1. This entire product approval form
2. A copy of the manufacturer's installation details and requirements for each product.
Category / Subcategory
Manufacturer
Product
Description
Florida Approval #
(include decimal)
1. Exterior Doors
Swinging
Sliding
Sectional
HAAS
MODEL 2480 8X7
FL16660.22-R7
Roll U
Automatic
Other - OVERHEAD
2. Windows
Single Hun
Horizontal Slider
Casement
Double Hun
Fixed
Awning
Pass Through
Projected
Mullions
Wind Breaker
Dual Action
Other
June 2014
�t
M
Category/ Subcategory
Manufacturer
Product
Description(including
Florida Approval #
decimal)
3. Panel Walls
Siding
Soffits
Storefronts
Curtain Walls
Wall Louver
Glass block
Membrane
Greenhouse
E.P.S Composite
Panels
Other
4. Roofing Products
Asphalt Shingles
Underla ments
Roofing Fasteners
Nonstructural
Metal Roofing
Wood Shakes and
Shingles
Roofing tiles
Roofing
Insulation
Waterproofing
Built up roofing
System
Modified Bitumen
Single Ply Roof
Systems
Roofing slate
Cements/
Adhesives /
Coating
Liquid Applied
Roofing Systems
Roof Tile
adhesive
Spray Applied
Polyurethane
Roofing
E.P.S. Roof
Panels
Roof Vents
Other
_
June 2014
__.
i
Category/Subcategory
Manufacturer
Product
Description
Florida Approval #
include decimal
5. Shutters
Accordion
Bahama
Colonial
Roll u
Equipment
Other
6. Skylights
Skylights
Other
7. Structural
Components
Wood Connectors /
Anchors
Truss Plates
Engineered Lumber
Railing
Coolers/Freezers
Concrete Admixtures
Precast Lintels
Insulation Forms
Plastics
Deck / Roof
Wall
Prefab Sheds
Other
8. New Exterior
Envelope Products
J
Applicant's Signature co �I--oh,) A)CcQL �
Applicant's Name d C, ( d �' 1
(Please Print)
June 2014
tom
EI
1 2 3 14 + 5
Door Width 9' - 2" Shown NOTE: For lite options see Sheet 3 of 3.
See chart below for other
door widths
op Bracket Strut &Strut Att
F,F;D1T1d1
aent
A (sheet 2.13) Detail J (sheet 2.1 3) rp
6 1 7
NOTE: Track configuration above
the door opening does not affect
the wind load rating of the door.
8
F.
at
2 of 3)
E
Slide Lock or Lock Bars
Door Height Detail O (sheet 2 of 3)
g Manual door locks are ,
8' _ 0" Shown required unless al automatic '
See chart operator is installed. DetalF(sJmbheetracket
p
below for other 66" +/- 3"
door heights'
i
D 382' +/- 3" i D
I � �
Qz
III �
Bottom Bracket L End Hinge Strut A Shut Attachment Intermediate Hinge
Detail C (sheet 2 of 3) Detail B (sheet 2 of 3) Detail E (sheet 2 of 3) Detail D (sheet 2 of 3) 1 01., +/ 3" Digitally signed by,John E. Scates P.E.
2 Date: 2017.09.29 15:58:08 -1
C This product hes been evaluated per ANSI/DASMA 108-05 (and —12) for static air pressure. Jamb bracket quantities shown are for use with grade 2 or better southern pine jambs. C
Supporting structural elements are to be designed by a registered professional engineer
Mod IN mber for specific wind loads.
e u
PAN C2460 8 R2460 SERIES
PAN C2461 8 R2461 SERIES
PAN C2470 8 R2470 SERIES
PAN C2410 8 R2410 SERIES
PAN C2471 8 R2471 SERIES
PAN C2480 8 R2480 SERIES
PAN C2472 8 R2472 SERIES
PAN C2481 8 R2481 SERIES
PAN R2560 SERIES
PAN C2011 SERIES
PAN C2482 a R2482 SERIES
PAN R2561 SERIES
PAN C2015 SERIES
PAN R26BO SERIES
PAN R2570 SERIES
PAN C2411 SERIES
B
PAN R2581 SERIES
PAN R2571 SERIES
PAN C2415 SERIES
PAN R2582 SERIES
PAN R2572 SERIES
PAN C2511 SERIES
Door Widths
Up To
Desi n Pressures
+ psf -psf
End Stile
Center
Center
Center
Impact
Resistant
Stiles
Hinges
Stiles
Stiles
Hin es
2
-27.0
Single
1
1
1
1
1
NO
-2
21.3
-24.1
Single
1
1
1
7Hinges
1
1
NO
10'-2"
17.3
-19.6
Single
2
2
1
2
2
NO
12'-2"
12.1
-13.6
Single
2
2
1
2
2
NO
Door
Height
Total
No.oi�^IMmebnkEm
Sections
Total # of Struts
Pam„^ anal Kc
n "v,uv e, me qnu
Jamb
Brkts/Side
6'-0"
3
3
2
6'-0"
4
3
2
6-3"
4
3
2
6'-6"
4
3
3
6-9"
4
3
3
T-0"
4
3
3
T-3"
4
3
3
T-6"
4
3
3
T6"
5
4
3
T-9"
4
3
3
T-9"
5
4
3
3
3
4
3
NOTICE:
��� �� t4 ///
These drawings are a supplement to the
r,�,6148�r•.
installation instructions for a standard door
and only covers those procedures that vary
`
` •"rJi
from standard door installation. If these
"� ' *:
•
specific procedures are not followed. the door
may not perform as designed.
t F _
.••-'Op\' TATE OF
H
NOTICE:
The lice section of this door may be replaced
0
with o section with another lite style or a
the
�/
/ •� \
solid section. In either case strut and
stile configuration should remain the some.
tQ
///��S oN' ` 6 \\1
B
NOTICE:
Only one lite section per door is permitted.
John E Scales, P.E.
The lite section con be used anywhere except
2560 King Arthur Blvd, Ste 124-54
for the bottom section. If the lite section is
Lewisville, Texas 75056
not the top section then the struts must be
Florida P.E. b 51737
located as shown in the STRUT
CONFIGURATION on page 3 of 3.
FI 01666(199 Professional
Engineer seal prodded only for
This product is designed and sold by PSF.
the AHJ or Engineer of Record is responsible for determining the Maximum section height is 24 in.
PSF required for any given site.
Maximum door height is 16 ft.
v -
DESCRIPTION Y ,rANanoasraleswn,tnn swtl
All doors. even those above the tested height,
_
LOAD SECTIONAL DOOR
A
are available with jamb brackets or commercial
- �'
DESIGN PRESSURE 121.31-24.1 PSF
A
full angle. The maximum spacing of the jamb
e -
ORIWIRR RLL: wL2000.UI10-0&21-24L fRFFf:1OF3 REV. F.
brackets/track clips should be maintained.
m C m%. i'n
DATE RRR: 9/14114 1 DRAWN IT: MVS
MODEll Sec Sheet 3
1 2
3 4 5 6
7 1 8
F- 1 2
3 4
5 6
7 B
PUSH NUT
23rr
PUSH NUT
7/16"
See DETAIL K for push nut
7/16
See DETAIL K for push nut
4 END HINGE
14 Ga Galvanized Steel
TEK SCREW
I/4" X 3/4" Hex Washer Head
F
placement.
a
placement.
TEK SCREW
g ( per Bottom Bracket)
Self Drillin 3ADJUSTABLE
F
TOP FIXTURE
1
1/4" x 3/4" Hex Washer Head
no
12 Go
TEK SCREW
1
Self Drilling (6 per Hinge)
BOTTOM BRACKET
TEK EW
1/a" XC3/4" Hex Washer Head
1/4" X 3/4" Hex Washer Head
Self Drilling (2 per Bracket)
NOTE- This screw should
q0J 13 Go Galvanized Steel
® Self Drilling (4 per Bracket)
he located below the prepunched
PUSH NUT
LOW HEADROOM TOP
hole and go through the hinge,
7/18"
END STILES
BRACKET
p end stile and skin edge.
See DETAIL K for push nut
18 Go Galvanized Steel
placement.
PUSH NUT
DETAIL A LOW
HEADROOM
7/16"
DETAIL B See DETAIL K for push nut
DETAIL C BOTTOM SEAL
E
placement.
E
TOP BRACKET
24'r INTERMEDIATE STILE
3 1/4" x 3 1/4" E STRUT
2.25" x 2.75" E STRUT
18 Go 70 Kt Minimum
18 Go Galvanized Steel
18 Go 70 KSI Minimum
Gazed Steel lvani
Galvanized Steel
��
JAMB BRACKET
12 Ca Galvanized Steel
z3"
o Q o INTERMEDIATE HINGE
18 14 Go Galvanized Steel
�r
� 34"
o
If
or
TEK SCREW
BOLT & NUT
24
D
D
1/4" X 3/4' Hex Washer Head
TEK SCREW
1/4-20 X 5/8" Carriage
TEK SCREW
g ( per Hinge) Self Drilling 4 e
1/4" X 3/4' Hex Washer
Boll & 1/4-20 Hex Washer
1/4" X 3/4" Hex Washer
i
DETAIL D
DETAIL E Head Self Drilling (2 per
DETAIL F Nat (I per Jamb Bracket)
DETAIL J Head Self Drilling (1 per End
End & Intermediate Stiles)
Stile & 2 per Intermediate Stile)
WITH AND WITHOUT
BRACE
00
NOTE:
Details on some views omitted for clarity.
Doubleend stiles and end hardware may be
01
r;.-
equired on wider or heavier doors.
°
o0 0 oapapa
0
SLIDE LOCK or LOCK BARS
`a 0 0 0
(not required with operator)
A
Q°
Maximum
o
°
o
y
1/2"
TEK SCREW
1/4" X 3/4" Hex Washer
��Illillttt//
RESIDENTIAL & LIGHT COMMERCIAL COMMERCIAL DETAIL K
Head Self Drilling (4 per
COMMERCIAL For Standard. High For Standard, High
Lift & Vertical Lifte There should be a
Slide Lock)
` �•,
NO 5iTV
For Low Headroom & Vertical
space of maximum
`,
r,
With 2" Track and With 2" Track and With 3" Track cnd 1/2" between the roller DETAIL
G
_
� * —
Single End Stiles Single End Stiles Single End
Stiles
hub and the outside
FLAG BRACKET
ALTERNATE BOTTOM BRACKETS
edge of the roller
o0 oo"op
8TA�
holder Which is set by
NOTE: The bottom bracket tested (shown in DETAIL C) is the lightest bracket ovoila ble.
the push nut.
BOLT I O P \ \
5 16 X 1 5 8" Lot Bolt // � `'�QR�D�e
/ / / \'
B
� (4 per Flag
Bracket). /�/ SYQ/QNA� Fi \�� ':
B
oo
`DOOR SKIN Min.
of 1' Mintmol 25 Go Galvanized Painted Steel of I' (1
BOLT &
1/4-20
NUT
P.E.
John E Scales,Arthur
X 5/8" Track Bolt John King Arthur Blvd. Ste 124-54
tJ�
& 1/4-20 Hex Washer Nut Lewisville, Texas 75056
32�[
(2 for Horizontal
Vertical Track)
& 2 for Florida P.E. # 51737
ROLLER
FL
Profess oval Eng neer seal provided only far
#16660.22 verificat an of wind load construction details.
BOLT & WASHER VERTICAL TRACK 2" Nom lot
5/16' X 1 5 8' Log Bolt & 2" O.D.
/ 9
Wool JAMB 2 Diameter Nominal
DESCRIPTION:
13 Gc Golvan zed Steel tested
x 7/16" I.D. Flat Washer _
Nominal Goa s aisa
The vert <al wood jamb Eleven Ball Nylon Or
fasteners may be counter sunk
9T R LOADWyEC7pNALDOOR D
M
A`
A
NOTE. Jamb bracket must be ;n a us
direct cant eel with the 2x6 (No PProved o Iternale.
to provide a flat mounting Ten Ball Steel With
Minimum Workable
DESIGN PRESSURE .21.3/-A.I PSE
tlrywaIf allawetl).
surface. See jamb attachment a
DRAWING NO.:R'1--?W0.UI IU-0B-:I.2CL RXFET:26F3 REV. E
r quire
NOTE: The fief wcsher 'is not e d
defogs on sheet 3 for attaching Shaft Length Shawn.
DETAIL H
am PATE URN: 8/14/14 DRAWN BY: YVS
forangle moan..
jombs to the structure.
ry.nxe
®c.rRYN�mi'� MODEL(S): See Sheet 3
1 2
3 4
5 6
7 1 8
IF
OPE
, HEI
E
DI
c. I
M=
FAI_
11 2
FAFiTFNFR Tn C:nNTINt IF
I
PAST HEADER
2 X 6 GRADE 2 OR BETTER SOUTHERN
PINE JAMBS.
'SEE
o
CHART FOR WOOD JAMB ATTACHMENT
TO BUILDING STRUCTURE.
41NG
OPENING
3HT
WIDTH
o
MAXIMUM ON
pit
r CENTER SPACING
FIRST FASTENER 4" to 10"
I
ABOVE THE FLOOR
SEC I ION
LIE
SE ION
L E
SEC I ION
3 SECTIONS 4 SECTIONS 5 SECTIONS
WITH LITE SECTION AT TOP
1 1 2
4 5 6 7 1 8
MODEL NUMBERS AND LITE OPTIONS
NOTE: GLASS OPTIONS ARE AVAILABLE IN DS8 MINIMUM, TEMPERED AND INSULATED GLASS LINRS. F.
WOOD JAMB ATTACHMENT
Building
Mlnlmum
Minimum
Minmum
M.kr—
Albwede
SUUCture
Fastener Type
Embetlmerrt
E10e
DI
Cereer
Spa
-C—er
T..ibn
,.—
Spaeiv
Up
Min. 2500 PSI to
Tape n + (PLUS)
2^
2.50"
5.00"
24'
551
4000 PSI Concrete
1 /4" wl i" OD washer
Southern Pine
3/8" Lag w/
1.50"
1.50"
1.50"
24'
620
1 1/8" OD washer
Spruce Pine Fir
3/8' Lag "'/
1.50"
1.50"
1.50"
24'
482
1 1 /8" OD washer
NOTE: 2X6 mounted to the Wall must be Southern Pine Grade 2 or better.
MODEL NUMBERS
AVAILABLE
PAN C2011 SERIES
PAN C2015 SERIES
PAN C2411 SERIES
PAN C2415 SERIES
PAN C2511 SERIES
PAN C2410 & R2410 SERIES
PAN C2460 & R2460 SERIES
PAN C2461 & R2461 SERIES
PAN C2470 & R2470 SERIES
PAN C2471 & R2471 SERIES
PAN C2472 & R2472 SERIES
PAN C2480 & R2480 SERIES
PAN C2481 & R2481 SERIES
PAN C2482 & R2482 SERIES
PAN R2560 SERIES
PAN R2561 SERIES
PAN R2570 SERIES
PAN R2571 SERIES
PAN R2572 SERIES
PAN R2580 SERIES
PAN R2581 SERIES
PAN R2582 SERIES
LITE OPTIONS AVAILABLE
CARRIAGE
HOUSE
RANCH
STANDARD
LARGE
CaMMERCUL
24x 12
SMALE
COMMERcuI
24 x6
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
_
X
X
X
38 1/2'
x 12 5/8"
38 1/2"
x 10 1/2"
17 1/4"
x 10 114"
21 112"
x 9 1/2"
21 112"
x 3 1/4"
DAY LIGHT OPENING (DLO) - WIDE x TALL
c
SECIE
E
ON
SEC
IE
ON
= No. 51737
LIE
LIE
SE
I ION
SE
ION
-is, , STATES fjj=
LIE
L
E
LIE/p0.(�..,.04ORMP'
p\�vvttN�` ..
SE
ION
SE
ION
SE
ION
B
John E Scotes, P.E.
2560 King Arthur Blvd. Ste 124-54
-
Lewlsvlie. Texas 75056
Florida P.E. # 51737
FL #�6660.22 Professional Engineer seal provided only far
verification of wind load construction details.
DESCRIPTION:
92' PAN 2(MSERIES W/I.ITIiSWIND
4 SECTIONS
6 SECTIONS
5 SECTIONS
7 SECTIONS
7 SECTIONS
a SECTIONS
8 SECTIONS
5 SECTIONS
7 SECTIONS
6 SECTIONS
8 SECTIONS
7 SEECTIONS
8 SECTIONS
7 SECTIONS
6 SECTIONS
LOAD SECTIONAL DOOR
` - DFSI(iN PRESSURE -21.V-24.1 PSF
A`
WITH LATE
SECTION
ANYWHERE
EXCEPT
B SECTIONS
THE
TOP AND
BOTTOM
SECTION
ORAWINONLL:Nil-2UgW11W13-21-24LSNEET:30F3 REV. E
STRUT
CONFIGURATION
Fmnrour N: R/ 4n4 x: Mvs
I
MOOEDATE
m ca�b�miiS°7 MODEL(S): See Sheet 3
Sheet
3 4 5 6 7 8