Loading...
HomeMy WebLinkAbout108 Aldean StCITY OF . ` Building & Fire Prevention Division FORDPERMIT APPLICATION APR 2 P � ja FIRE aEPaltTMENI� Application No: q0 ���� Documented Construction Value: 10$ I.JLJ - Job Address: b Historic District: Yes ❑ No ❑ Parcel ID: Residentialo-Commercial❑ Type of Work: New❑ Addition Alteration❑ Repair Demo[] Change of Use❑ Move❑ Description of Work: ,0ee%cerim f ©T h vat; -V5� ell-7 Wt /-/, o /70j�-7 Plan Review Contact Person: -61(� CGS'�� —i(`C, Title: C?�f�C � Phone: Z&(o 'R (o 9531 Fax: Email: ? n ��l �P_ 1-}` " �C _ C0' Property Owner Information Name Phone: Street: Resident of property? City, State Zip: 4A ALV �_L Cle wv,^,,4 A (ram Contractor Information Name G� Phone: �C� Street: �y�/� y Fax: /� City, State Zip: � `Chu/ G l6 State License No.: QT U �, Name: Street: City, St, Zip: Bonding Company: Address: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6' Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application U l �Q 3� •NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is. Personally Known to Me or Produced ID Type of ID 0 Signa of Contractor/Agent Date )e&-- k4q Print tractor/Agent's Name C,6z�Ap Signature of Notary -State of Florida Date 'PNOTARY PUBLIC STATE OF FLORIDA Cornrn# FF958204 Personally E-VIres 2/8/2020 Contractor/Agent is Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical Q Plumbing❑ Gas ❑ Roof ❑ Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes ❑ No ❑ APPROVALS: ZONING: ENGINEERING: COMMENTS: # of Heads UTILITIES: FIRE: Flood Zone: # of Stories: Plumbing - # of Fixtures, Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: Revised: January 1, 2018 Permit Application JIMMY PATRONIS CHIEF FINANICAL OFFICER STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW * * CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: 9/29/2017 PERSON: BRAY FEIN: 475007601 BUSINESS NAME AND ADDRESS: ELEMENT AIR & REFRIGERATION LLC 25 PUTTER DRIVE PALM COAST FL 32164 SCOPE OF BUSINESS OR TRADE: Heating, Ventilation, Air - Conditioning and Refrigeration Systems Installation, Service and Repair, Shop, Yard & Drivers EXPIRATION DATE: 9/29/2019 lkwup N z IMPORTANT: Pursuant to Chapter 440.05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter. Pursuant to Chapter 440.05(12), F.S., Certificates of election to be exempt... apply only within the scope of the business or trade listed on the notice of election to be exempt. Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt and certificates of election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. DFS-F2-DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 08-13 QUESTIONS? (850)413-1609 SCPA Parcel View: 34-19-30-518-OD00-0070 Page 1 of 2 na alaMesancrn amagy Record Card PP Parcel: 34-19-30-518-OD00-0070 OM R rcnarxxazcc�. env, rx� Property Address: 108 ALDEAN DR SANFORD, FL 32771-3662 Parcel Information Value Summary .......... 2018 Working 2017 Certified Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value $141,855 $133,567 Depreciated EXFT Value $8 663 $5 875 Land Value (Market) ; $45 000 $37 500 Land Value Ag Market Value " $195,518 $176 942 R Portability Adj j 0 ! Save Our Homes Ad/ I $0 $0 Amendment t Adj $882 $0 P&G Adj $0 $0 - - 1 Assessed Value $194,636 $176,942 )_ Tax Amount without SOH: $3,369.00 ,'fir r 2017 Tax Bill Amount $3,369.00 �a Tax Estimator Save Our Homes Savings: $0.00 A ' Does NOT INCLUDE Non Ad Valorem Assessments 95 80 rb Seminole County GIS Legal Description LOT 7 BLK D �� w IDYLLWILDE OF LOCH ARBOR SEC 4 PB 16 PG 100 Taxes Taxing Authority Assessment P -�� --- � Value � Exempt Value s Taxable Value County General Fund 1, $194,636 $0 $194,636 Schools $195,518 $0 i $195,518 __--_-- City Sanford $194,636 ! $0 $194,636 SJWM(Saint Johns Water Management) $194,636 $0 ! $194,636" County Bonds $194,636 ` $0 ' $194,636 Sales l Description — Date Book Page Anount Qualified Vac/Imp WARRANTY DEED 5/1/2016 08714 1862 $100 ! No Improved WARRANTY DEED 9/1/2015 08557 0848 $220 000 Yes Improved _....... - j _ _ _ _. _ _ _. ___ .. . QUIT CLAIM DEED 10/1/2005 i 06127 0839 $100 ( No Improved QUIT CLAIM DEED j 4/1/2005 05740 0833 [ $100 No Improved �roved QUIT CLAIM DEED 12/1/1989 02146 0715 $10IQUIT CLAIM DEED 8/1/1989 02277 1063 $100 No Ived 01393 1759 $82 500 Yes Improved WARRANTY DEED 5/111982 _ " WARRANTY DEED �1/1/1975 01068 E 1948 $46 900 = Yes Improved Find Comparabl, Safes _..__. �. Land Method Frontage Depth Units Units Price Land Value LO T 0.00 , 0.00�t $45,000.00 $45,000 J http://parceldetail.scpafl.org/ParcelDetailInfo.aspx?PID=3419305180D000070 4/20/2018 ESTI MATE Element Air & Refrigeration , LLC Element Air & Refrigeration, LLC All mailing: 25 putter dr, palm coast, FL 32164 Physical Estimate # address: 101 Hibiscus ave Bunnel FL suite#911 Date Bunnell, FI 32110 Phone: (386) 986-9931 Business / Tax # Email: rbray@element-Ilc.com Web: WWW.ELEMENT-LLC.COM Description Grala Steve 108 Aldean Dr Sanford, FL 32771 (321) 696-9842 002186 06/30/2016 FL LICENSE # CAC1818305 INSURANCE # 1000362336151 4.0 TON HEAT PUMP BRYANT-CARRIER REPLACEMENT W/NEW DUCT SYSTEM INSTALLATION ELEMENT AIR AND REFRIGERATION, LLC IS PRESENTING THE PROPOSAL TO REMOVE FAILED AIR HANDLER AND CONDENSING SYSTEM, AND REPLACE WITH NEW 14 SEER BRYANT (CARRIER) HEAT PUMP SYSTEM. INSTALLATION IS TO INCLUDE THE FOLLOWING: -REMOVAL AND DISPOSAL OF FAILED SYSTEM -RE-SIZE OF ELECTRICAL BREAKERS IF NECESSARY -INSTALLATION OF HURRICANE RATED 150 MPH CONCRETE PAD PER FL BUILDING CODE -INSTALLATION AND MODIFICATION OF DRAIN LINES -INSTALLATION OF NEW ALUMINUM AIR HANDLER STAND -PROPER EVACUATION AND RECOVERY, SYSTEM EVACUATED TO <600 MICRONS AND PURGED WITH NITROGEN AS PER MFG SPEC FOR INSTALLATION -ALL NECESSARY DUCT WORK MODIFICATION OF PLENUM TO ATTACH NEW SYSTEM TO EXISTING DUCT WORK - PLENUM TO BE SEALED WITH FAB CLOTH, METAL TAPE, AND MASTIC AS PER ENERGY STAR SPECIFICATION - ANCHOR CLIPS TO BE USED TO FASTEN NEW CONDENSER TO PAD -INSTALLATION, SET UP AND CALIBRATION OF NEW 4 TON BRYANT 14 SEER HEAT PUMP CONDENSER MODEL# 1214DNA04800 -INSTALLATION, SET UP AND CALIBRATION OF NEW MATCHING 4 TON BRYANT AIR HANDLER MODEL# F134CMP04800 - THERMOSTAT OPTION HONEYWELL 6000 PROGRAMMABLE W/ SCHEDULING 2H/1 C -AUXILIARY HEAT INCLUDED INSTALLATION OF NEW 7/8 AND 3/8 COPPER LINE REFRIGERANT LINE SET. WITH 3/4" WALL INSULATED ARMAFLEX Total $6,500.00 Page 1 of 3