Loading...
HomeMy WebLinkAbout2004 Northlake DrA0R 1 0 2018 t CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION w Application No: Documented Construction Value: $ Job Address: Wq Ootthlgke Lam. 6Ve- 3M3 Historic District: Yes ❑ No ❑ Parcel ID: ILj -20-30- 5i6 -2000 2004 Residential ® Commercial ❑ Type of Work: New ❑ Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: Qpnlace 10 (.t�lne�x�5 Size Gr- 5i7-e Plan Review Contact Person: JOnnXR4 lacti l Title: Phone: 14d7 389 1 q00 Fax: Email: oefrn)-1 0 lUlncbW>enrtd GTbn60 cc, Property Owner Information Name )QmES Fctrn5wortY1 Phone: 8(o3- �QG - ?I(pO Street: _QW 1( Resident of property? : U City, State Zip: _ SQnCpr6 FL 2-2,73 Contractor Information Name Michael Tillman Window World Street: 3882 Center Loop City, State Zip: Orlando, FL 32808 Name: Street: City, St, Zip: Bonding Company: Address: Phone: 407-389-1400 Fax: 407-389-1402 State License No.: CGC 1514205 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51h Edition (2014) Florida Building Code - n 0 Revised: June 30, 2015 Pennit Application '� �1 NOTICE: In addition to the requirements of this permit, There may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713). The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signa rre o caner/ gent Date ignature of ontractor/Ag t Date Print Owner/Agent's Name Print Contractor/Agent's Name Signature Owner/Agent is Produced ID Signature Date 1>4.:�oE•. JEN'NIFERMASON _°; •` Notary Public - State of Florida : ;» JENNIFER b1ASON Commission � GG 181615 `?c; Al Notary Public - State of Florida My Comm. Expires May 27, 2022 Commissior. = GG ' 8' 615 .: " Bonded through National Notary Assn. :F�r . My Comm. Exoires Vay 27, 2022 Bonded through National Notary Assn. ersona y nown to e or Contractor/Agen Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas ❑ Roof ❑ Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: FIRE: COMMENTS: Flood Zone: # of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: cr 4a q& Revised: June 30, 2015 Permit Application RIEQUIIRIEIID INSF EcCTI ON SIEQUIEN CIE Bpff I A - 1 " 1T9 Address: avimtDE14C. PF-1 'r MIln Max I[ns e��ll®n IlDesen�i ill®nn. aaa a Footer / Setback Stemwall Foundation / Form Board -Survey Slab /Mono Slab.Prepour Lintel / Tie Beam / Fill / Down Cell Sheathing— Walls' Sheathing— Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Roof Final Stucco. / Siding insulation Final Final Utility Building - Final Door. Final Window - Final Screen.Room Final. Pool Screen Enclosure Mobile Home Building Final Pre -Demo Final Demo. Final Single F�amiTyResidence Final. Building. Other VV 1 � U We IPr�¢at�➢ � .... _. . Imn Mgt line eein®n.I[Desen•i2fl®n Electric. Underground F ooter /' Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final .t _ 1.g11 Jf.,bwY �; \ V t7tittlf. �LVi.Wjl� �iq;Ww=t\/I w'..4 c(� '��tiicl �+t3t��l�i`I _ f MllIIn Max lhmecdon DeSCId DdOn Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final ~_ 1f1 Iln max. ks ecdon DeseICj2!!2n Mechanical Rough Mechanical. Final �x min Max rMsRection.Descrif2do.n Gas Underground Gas Rough Gas Final RIEVIS El1D: Yane 2014 SEMINOLE COUNTY MULTI%URISDICTIONNL LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: 04/09/2018 hereby name and appoint: JORGE TORRES an agent of: WINDOW WORLD (Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): ❑ All permits and applications submitted by this contractor Or The specific permit and application for work located at: 2004 Northlake Drive, Sanford, FL 32773 (Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: State License Number Signature of License F STATE OF FLORI COUNTY OF MICHAEL TILLMAN Theforegoing instrument was acknowledged before me this day of I , 20 , by A k k__0 C j�-R'A -- who is�ersonally known to me or ❑ who has produced and who did (did not) take an oath. C —1y � Signaftfie of Notary as identification Print or type Notary name ,•tipr'a�E:• JENNIFER MASON NotaryPublic- StateofFlNotary Public -State of�- 9�Q, Commission =GG'St6 I �I ;oF F o,: My Comm. Expires May 27],Y20 Commission No. "''" Bond. trough National Notar My Commission Expires: G THIS INSTRUMENT PREPARED BY: Name: Window World 3`I Address: 3882 Center Loop Orlando FL 32808 NOTICE OF COMMENCEMENT State of Florida County of Seminole Permit Number: GRANT I'IALOYT HNINOLE COUNTY C:i._ ::M OF r_ IRCUIT COURT & CONPTROLLER BK 91Ci7 Ps 1272 (1P:j-,) CLERK'S 4 2018038748 RECORDED 04.i111/21_i18 111C1.18"- 6 i.^-WI RECORDING FEES $10.00 RECORDED BY hdevore Parcel ID Number: 1 y .? 0 30 - J 1 F - .>2 W " 2CO Li The undersigned hereby gives notice that improvement will be made *to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) Unit 2OOLI R lc)c1 20 _ Nof-thICIVie Vil1Qw2 10 PC, Ll I 4)G5 70 Thry -7-2 GENERAL DESCRIPTION OF IMPROVEMENT: 12 F,nlCxce IG IUIn 0Gu-1; OWNER INFORMATION: Name: JOrneL vc'f n5ccof'-01 Address: NoSthlUkz �Snn(�Tfcl L ,32`7'73 Fee Simple Title Holder (if other than owner) j(V CONTRACTOR: v Name: Michael Tillman Address: 3882 Center Loop Orlando, FL 32808 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: Address: In addition to himself, Owner Designates of To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713,13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the bestofmy knowledge and belief. PO O c 0 er's na ure Owner's Printed Name Florida Statute 713.13(1)(g): " The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead." J State of Lk County of The foregoing Instrument was acknowledged before me this day of yp <Gc by - " C� �`� �'C•^'�-r"l'�-'�-�� ` .Who is personally known to me ❑ =� r�-� o Name of person making statement l� \. ---- OR who has produced identification ❑ type of identification produced:C) ����• •' y'.. JENNIFER MASON v t s Notary Public - State of Florida %f Cor'irnission 4 GG 181615 My COMM. Expires May 27, 2022 r " Bonded through National Notary Assn. Notary Signature v m [ 4/3/2018 SCPA Parcel View: 14-20-30-518-2t)00-2004 11 1�1 u Ahnson, CIA PWO SEtim+cxEr�rrv. Property Record Card Parcel: 14-20-30-518-2000-2004 Property Address: 2004 NORTHLAKE DR SANFORD, FL 32773 Parcel 14-20-30-518-2000-2004 Owner FARNSWORTH, JAMES D Property Address 2004 NORTHLAKE DR SANFORD, FL 32773 Mailing 2004 NORTHLAKE OR SANFORD, FL 32773- Subdivision Name NORTHLAKE VILLAGE 10 Tax District j S1-SANFORD DOR Use Code 04-CONDOMINIUM Exemptions 00-HOMESTEAD(2015) Legal Description UNIT 2004 BLDG 20 NORTHLAKE VILLAGE 10 PG 41 PGS 74 THRU 77 Taxes Value Summary I 2018 Working 2017 Certified Tax Amount without SOH: $439.00 2017 Tax Bill Amount $333.00 Tax Estimator Save Our Homes Savings: $106.00 * Does NOT INCLUDE Non Ad Valorem Assessments Values Values Valuation Method � Cost/Market Cost/Market Number of Buildings � 1 ( 1 Depreciated Bldg Value i $53,872 $48,100 Depreciated EXFT Value C —� Land Value (Market) Land Value Ag � Just/Market Value $53,872 $48,100 Portability Adj Save Our Homes Adj � $10,448 $5,569 �. Amendment 1 Adj !so P&G Adj !so i $0 Assessed Value � $43,424 ! $42,531 Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund $43,424 $25,000 1 $18,424 Schools — $43,424 � $25,000 i $18,424 �--_--$25,000---�-$18,424 City Sanford $43,424 SJWM(Saint Johns Water Management) � $43,424 $25,000 � $18,424 County Bonds $43,424 $25,000 j $18,424 Sales Description Date Book Page Amount Qualified Vac/Imp SPECIAL WARRANTY DEED � 11/1/2011 ': 07667 1733 $31,000 i No � —$100 Improved CERTIFICATE OF TITLE 12/1/2010 � 07488 1646 ' � No Improved SPECIAL WARRANTY DEED f 11/1/2010 07524 0040 � { $100 No Improved WARRANTY DEED —� i 4/1/2008 � 06986 0860 $108,500 � Yes Improved WARRANTY DEED � 12/1/2001 04274 11732 I $64,000 ;Yes Improved WARRANTY DEED 14/1/1998 y 03406 1316 � $48,000--Y-Yes Improved SPECIAL WARRANTY DEED 4/1/1998 03406 � 1313 � $42,100 No Improved — SPECIAL WARRANTY DEED � 1 9/1/1997 03312 0326 � $100 i No � Improved CERTIFICATE OF TITLE 9/1/1997 ' 03301 11627 $54,100 j No Improved WARRANTY DEED �3/1/1990 ! 02167 1247� $51,100 j Yes Improved Find Comparable Sales Land http://parceldetail.scpafl.org/ParcelDetaillnfo.aspx?PID=14203051820002004 1/2 ,3fiTM • "Simply the Best for Less" 3882 Center Loop, Orlando, FL 32808 (407) 389-1400 • 1-800-NEXT-WINDOW • (407) 389-1402 Fax windowworldorlando.com / CGC 1514205 Name: -'sG1PlS i �i, rA!yti�WDf InstallAddress: State, Zip: cArlr-VfPf- / T k 4- DOUBLE HUNG _jeries 4000 DH Insulated 101U1 _ ries 4000 DH Insulated 102-114U1 _ Series 4000 DH Insulated over 114U1 _ Series 6000 DH Insulated 114U1 Series 6000 DH Insulated over 114U1 3 Email: $ 189 $ 240 $ 340 $ 275 $ 375 SLIDING 2 Lite Slider Insulated < 90 UI $ 259 2 Lite Slider Insulated $ 369 3 Lite Slider Insulated > 121 UI $ 449 3 Lite Slider Insulated < 121 UI $ 649 IMPACT WINDOWS / DOORS Single Hung $ Double - Hung $ 2 & 3 lite slider $ Fixed Glass $ Sliding Patio Door $ OPTIONS Half Screens $ 39 Full Screens $ 59 _ Solar Zone Elite Low-E Glass/Argon $ 129� Tint Gray/Bronze $ 69 Flat Colonial Grids $ 79 Contoured Colonial Grids $ 99 Beige Color $ 79 Wood Grain, Interior (4000 or 6000) $ 109 Architectural Exterior Color $ 169 MISCELLANEOUS J Channel Application 1 $ 69 Custom Exterior Cap & Wrap Installation/Trim Packs $ 99 $ 119 Mull to Form Multi -Unit $ 69 Tempered DH Sash (BSO) (TSO) $ 59 Tempered (Fixed Units) $ 12/Sq. Ft. Obscured Glass $ 69 Engineering Fee $ 369 Code Compliant Plywood Services>101IJI $ 109 Code Compliant Plywood Services < 101U1 $ 89 Code Compliant Plywood Sliding $ 209 Phone (H): 0103 Fflf ofy Phone (W)- a3' Z t / _( 5/7 (.80 Multiplier) SPECIALTY PATIO DOORS Vinyl Sliding Patio Door 5' x 6' 8" $ 929 Vinyl Sliding Patio Door 6' x 6' 8" $ 1039 Vinyl Sliding Patio Door 8' x 68" $ 1189 Vinyl Sliding Patio Door 9' x 6' 8" $ 1529 Vinyl Sliding Patio Door 12' x 6' 8" $ 2059 Vinyl Sliding Patio Door 5' x 8' $ 1319 Vinyl Sliding Patio Door 6' x 8' $ 1569 Vinyl Sliding Patio Door 8' x 8' $ 2279 Vinyl Sliding Patio Door 9' x 8' $ 2589 Vinyl Sliding Patio Door 12' x 8' $ 2989 Sliding Door Screen $ 139 Colonial Grids $ 209 Solar Zone Elite Low-E / Argon $ 319 Removal & Install $ 350 Custom Exterior Trim $ 149 Beige Color $ 289 Architectural Exterior Color (6'-9') $ 459 Specialty Sliding Door Blinds 5' - $675 6' - $850 8'- $975 9' - $1225 12' - $1500 Customer agrees to make themselves available to the city and/or county inspectors for a final inspection 1! NO EXTRA WORK IF NOT IN WRITING!! *Received ptywood code (Volusia) St. Jude's Donation $ Other $ Setup & Disposal Fee $ $ 100.00 Permit & Fees $ //$ 289.00 Total Amount $ SCE 10 Custom Order Deposit 50% $ 1;243 C�Q v� Balance Paid to Insaller upon Completion $ C;ZZ5p�. ev CHECK RETURN FEE $59 Buyer agrees that he has read and understands all terms and conditions on front Please see reverse for additional terms &con itions and back of this contract and agrees to every term and condition. l Sal n Date White Copy - Original Own Date Yellow Copy - Customer WWWIN02118 WINDOW MEASUREMENT ORDER FORM 1 2 3 4 5 E 7 E 5 1C 13 ? 1 14 1° 1( I V V 2( 2: 2� 2: 24 2! 21 2' 21 NAME: Farnsworth, ! # OF STORIES : 1 MEASURED BY: 039 Mike Barr DATE: 4/3/18 TYPE OF CONSTRUCTION: BLOCK TYPE OF WINDOWS: ALSH 1# OF WINDOWS: 10 INSTALLERS NOTES: May need small ladder DRAWING SCREWED IN X_STUCCO x_BRICK OTHER w 8>0>E> 8S,wbc,Zm zc=�mD=cn�o cn�o�^zOm� O vcnn � 9pP=28mm0 r-_m 10 <-4nD<m, ZrAcon-c ..a 4pTmzD-acm) O'�pOo o � MF.DZ ow 002m=>7D� �a =�mgMTZ>M C��'u=�Z0 OZmTC5m�rn N mcn m>-4>> co -a m A" ASSOCIATED SSOCIATED MATERIALS 'Aj IN P O R AT ED 3773 STATE ROAD CUYAHOGA FALLS, OH 44223 MODEL 300713BO113A01/3AB1 "ST" EXTRUDED VINYL DOUBLE HUNG "Replacement" WINDOW WON -IMPACT GENERAL NOTES 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product is required to be protected with an impact resistant covering that complies with FBC Sections 1609.1.2 & R301.2.1.2. 4. For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS SHEEN DESCRIPTION 1 Typical elevations, design pressures & general notes 2 Horizontal cross sections 3 Vertical cross sections 4 Buck and frame anchoring 5 Bill of materials, components and glazing detail FRAME WIDTH 2 w x w / / 2 w / X / OVERALL :FRAME DIMENSION MAX. D:LO. (TOP) MAX. D.L.O. (BOTTOM} G[ASS TYPE DESIGNPRESSURE(PSF) POSITIVE, NEGATIVE 36.0" X 60.0" 29.12" X 25.75' 30.12" X NIS' G1 +50.0 -60.0 36.0" X 72.0" 29.12" X 31.75' 30.12" X 32.7S' G1 +50.0 -55.0 36.0" x 78.0" 29.12" X 34.75' 30.12" X 35.75' G1 +45.0 -45.0 44.0" x 750' 37.12" X 33.25' 38.12" X 34.25' G1 +35.0 -35.0 52.0" x 62.0" 45.12" X 26.75' 46.12" X 27.75' G1 +35.0 -35.0 48.0" x 84.0" 41.12" X 37.75' 42.12" X 38.75" G1 +30.0 -30.0 44.0" x 96.0" 37.12" X 43.7S' 38.12" X 44.75" G1 +25.0 -25.0 52.0" x 96.0" 45.12" X 43.75' 46.12" X 44.75' G1 +155 0 15.0 X n DATE: 1 111217,5 SCALE N. T. S. DWG. Br: JK CHK. BY, LFS DRAWMG NO.- FL- 11720.9 SHEET 7 Of rJ k 1-141MIN. EMB. 1-1/4' MIN. INTERIOR EMB' EXTERIOR 1 HORIZONTAL CROSS SECTION y N Buck construction INTERIOR EXTERIOR INTERIOR EXTERIOR NOTE Sheet Metal Screws must penetrate a min. of 3 threads through at least two (2) sheets of metal. Maintain 51r min. edge distance. 1'4-'� HORIZONTAL CROSS SECTION Q Shown w/ Steel Stud Framing Option Shown w/ MED Bottom Sash Stiles ON•; v a x20 S C W � Ct a a � "� o a 'm o 0 E E 9z u W 8 �a Z 3 p W Z En 3 N j en J O m V = W •-� al Q O a oIo _ INTERIOR EXTERIOR DATE: 11112113 SCALE: N.T.S. DWG. BY: JK CHK. Br: LFS DRAN9NO NO.: FL-1 1720.9 SHEEP 2 OF S d°p*cjj�-z ca : 00 • znp ... ....... `�� J j m B D z I n rns+ z o ao d 0,00 C fm �ta7 U •;zj O C. 0 L Nacm n w mo IL t 8 w 0 z s: 8 �y 7 12 18 z Z o 20 3 � G1 9 12 20 z" o EXTERIOR INTERIOR 12 E= _ 15 m < 1 $ VERTICALCROSSSECTION Dc Buck construction 14 �I o 3 14 b a a 4 12 12 4 J J J m EXTERIOR INTERIOR 4 N m Gt GI 13 GI B 12 B 2 N N 0? EXTERIOR 12 w N j 12 INTERIOR 2 0 z 2 19 INTERIOR oQo0.0_w � N Z 18 2 EXTERIOR 0 1 B a ��~ww� z z �N U 18 c6 B i E � �w QaQQaw Pa E ioc p a o00000 a0.0.0.0_ > > > Q E D S ? o `Oh O✓lN d• Z 0 U DATE 11 112113 z • • a SCALE: N.T.S. 2 VERTICAL CROSS SECTION 3 VERTICAL CROSS SECTION MO. BY: JK M. 4 VERTICAL CROSS SECTION 3 2x Buck Construction 3 Optional masonry sTI OHK. BY: LFS 3 rc 3 Optional masonry sill Shown wJ MED Bottom Sash Rails oRnwiHc Ho.: N Shown w/ MED Bottom Sash Rails FL-1 1720.9 0 N SHEET _L OF 2X BUCK MASONR' OPENING 4" ITYP.) ---i I---- i FRAME P 2X BUCK _ L TYP. EXTERIOR INTERIOR TRACK TRACK FRAME ANCHORING BUCK ANCHORING (2X Buck) CONCRETE ANCHOR NOTES: 1. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortar joints. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortar joints, additional concrete anchors may be required to ensure the 'MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: MASONRY OPENING ANCHpR :ANCHOR MIN. MIN. CLEARANCE MIN. CLEARANCE TYPE SIZE ? EMBEDMENT TO MASONRY TO ADJACENT EDGE;; ANCHOR: ITW ®. 1/4" 1-1/4" 2" 4" TAPCON ELCO ® 1/4" T 1/4" V. 4- WOOD WOOD SCREW INSTALLATION NOTES: 1. Maintain a minimum 5/8" edge distance, I"end distance, & I"o.c. spacing of wood screws to prevent the splitting of wood. INTERIOR EXTERIOR TRACK TRACK 4' i Z �r Ss� 4W ''�I ••••.. 00 - J r .... •) ��� O m m ; 11l O 17 Z UN• V a d Z E. zm°ems S u g 9 `E a a L a� 6 H IXBUCK E 0'z 1XBUCK G DIRECT TO MASONRY — v o 3a K STEEL T, z FRAME TYP. 3 3 - Z � w ONRY = w OPENING `4 . j O O U O K m a a m U U m m ut � FRAME ANCHORING o w w (1 X Buck, Direct to Masonry, Steel Stud) o o p a a w z DATE: 11 12113 i SCALE N.T.S. DWG. sY: JK CHK. BY. LFS 3 a DRAWING NO- FL— 11720.9 n SHEET 4 or $ 63 BILL OF MATERIALS REM # DESCRIP110N MATERM A 1 X BUCK (SG >= 0.42) WOOD B 2X BUCK (SG >= 0.42) WOOD C 1 /4" MAX. SHIM SPACE D 1 /4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE F #10 X 2-1/7' PFH WOOD SCREW (1-3/8" MIN. EMBEDMENT) STEEL G 1 /4" x 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL H 1 /4" X 3-1 /4" PFH ELCO OR ITW CONCRETE SCREW STEEL K #10 PFH SELF -DRILLING SMS STEEL L #10 X 2-1 /4" PFH WOOD SCREW (1-5/16" MIN. EMBEDMENT) STEEL X STEEL STUD Min. Thk .033" (ASTM A653 GRADE 33 Fy=33 Ksi Min, Fu=45 Ksi Min) STEEL 1 EXTRUDED VINYL HEAD AND JAMB * RIGID PVC 2 EXTRUDED VINYL SILL* RIGID PVC 3 EXTRUDED VINYL LOCK RAIL * RIGID PVC 4 EXTRUDED VINYL MEETING RAIL* RIGID PVC 5 EXTRUDED VINYL SASH STILE (MED) * RIGID PVC 6 EXTRUDED VINYL LOCK RAIL (MED) * RIGID PVC 7 EXTRUDED VINYL HEAD INSERT * RIGID PVC 8 EXTRUDED VINYL BOTTOM LIFT RAIL * RIGID PVC 9 EXTRUDED VINYL TOP PULL RAIL * RIGID PVC 10 BALANCE COVER 11 EXTRUDED VINYL SASH STILE* RIGID PVC 12 GLAZING BEAD* RIGID PVC 13 EXTRUDED VINYL BOTTOM LIFT RAIL (MED) * RIGID PVC 14 REINFORCEMENT - MEETING RAIL STEEL 15 REINFORCEMENT- LOCK RAIL STEEL 16 REINFORCEMENT - SM. STILE STEEL 17 REINFORCEMENT - MED. STILE STEEL 18 WEATHERSTRIP (FIN PILE) 19 WEATHERSTRIP (VINYL BULB) VINYL 20 CAM LOCK STEEL * THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". . pm������ 0 1 —0.071 1RC 0.76" 0.75" C 0 in 0.061—E01. 0.06, 1" ---I F�-1.07' - ►I 16 REINFORCEMENT T REINFORCEMEM SM Sh1es MED Stiles f� 3.25 I � 0.06" i cO J N 3.95' T HEAD d JAMB 0.04" k tl1:j 2 SILL 2.04!' I I 0.065' `o 0.065' o, I 0.065' 2.ON' --i i- 1.3" 9 TOP PULL RAIL 8 BOTTOM UFT RAIL T 3 BOTTOM UFT RAIL MED 1.35' l .5S' �{ 1.55' -j j I LsS .065' 9 o � d o 11 SASH rntE 6 LOCK RAIL 3 LOCK RA4 MED Lzs - .065' 1� -{ 0.91" S SASH STILE Bottom Sash MED �? 1.39" 0 HEAD INSERT I-- 0.36" 0.05 12 GLAZING BEAD 0 o 1.57" 4 MEETING RAIL 1 /2' GLASS BITE --}�--�-I GLAZING TAPE 13/16" THICK GLASS � 1/8"ANNEALED GLASS FAIR SPACE STEELSPACER G1 GLAZING DETAIL ANNEALED GLASS Dm �aM »m� N M onmz a xz'a Z m U S6oa m aa.� DATE: 11 / 1211 SCALE: N.T.S. M. BY: JK CHK. BY: LFS DRAWING NO.: FL-1 1720.9 SHEET 5 OF 5 ri Comments Archived Product Manufacturer Associated Materials Inc. Address/Phone[Ema€1 3773 State Road Cuyahoga Falls, ON 44223 (330) 922-2108 rickwarwbid gconsultants. corn Authorized Signature Vivian Wright rickwOrwbldgconsultants, com Technical Representative Address/Phohe/Emafl Quality Assurance Representative A40resvphone/Emall Category Windows Subcategory Double Hung Comps€ante Method Evaluation Report from a Florida Registered Architect or a licensed Florida Professional Engineer Evaluation Report - ►lardcopy Received Florida Engineer or Archltect Name who developed Lyndon F, Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity Architectural Testing; Inc. Quality Assurance contract Expiration Gate 12/31/2020 Validated By Ryan J. King, P.E. Validation Checklist. Hardtopy Received Certificate of IndependenceltaL a�! Ql a1 art of In e" �5 Referenced Standard and Year (of Standard) Mgpdard year ANSI/AAMA/NWWIJA 1011I.S.21A440 2006 ANSI/AAMA/NWWDA 10I/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2005 Equivalence of Product Standards Certified By Sections from the code Quick Notes Page 1