Loading...
HomeMy WebLinkAbout2425 Bay Ave.� CITY 01;- ;; J Building &Fire Prevention Division PERMIT APPLICATION Application No: / (P— % 10 Documented Construction Value: $ 4407.68 Job Address: 2425 Bay Avenue Historic District: Yes❑Nowl Parcel ID: 31-19-31-520-0000-1300 Residentiala Commercial Type of Work: New❑ Addition❑ AiterationFI RepairW Demo Change of Use❑ Move Description of Work: Hvac Equipment Change Out with Ductwork C.. . Plan Review Contact Person: Eddie Palmateer Title: Pres/CEO Phone: 386-668-8651 Fax: 386-668-7758 Email: epaimateer@aceac.com Property Owner information Name Phillip Smock Phone: 407-221-2329 Street: 2425 Bay Avenue Resident of property? : Yes City, State Zip: Sanford, FL 32771 Contractor Information Name Ace Air Conditioning, Inc Phone: 386-668-8651 Street: 2985 Enterprise Rd Fax: 386-668-7758 City, State Zip: Debary, FL 32713 CAC1813533 State License No Name: Street: City, St, Zip: Bonding Company: Address: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6"' Edition (2017) Florida Building Code A _ Pi Revised: January 1,2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713, The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating cons tion and zoning. Signature of Owner/Agent Date Signature of Contractor/Agent Date w I c T -er Print Owner/Agent's Name Print Contractor/Agent's Name Signature of Notary -State ofFtorida Date ff. LDac ;.`�,gro"'•,,, BRENDAGALEHARNISH �• Notary Public» State of Florida Comm.issitn # GG 169359 My Comm. Expires Dec 19, 2021 Bondart ;luuwl` National Nolary Rssa. Owner/Agent is Personally Known to Me or. Contractor/Agent is n to Me or Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas❑ Roof ❑ Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads Fire Alarm Permit: Yes ❑ No E APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: V 4 a- COMMENTS: Revised_ January 1, 10IS Permit Application SCPA Parcel View: 31-19-31-520-0000-1300 http://parceldetaii. scpafl. org/Parceit)etaillnfo. aspx?Pl D=3119315200... Property Record Card Parcel: 31-19-31-520-0000-1300 r Property Address: 2425 BAY AVE SANFORD, FL 32771 Parcel Information GIS _ ..._..... .............. Legal Description LOTS 130 & 132 (LESS E 25.49 FT) & N 17 FT OF LOT 134 (LESS E 25.49 FT) SANFO PARK PB5PG62 I Value Summary .................. ._............ _........_._...... 2018 Workin9 2017 Certified Values Values ......... ...... _................. ..... ..__............... ... ... Valuation Method _,._._._...._. .................... ...._._...;.. Cost/Market _...__..... ........... .... ..._.... ..; Cost/Market Number of Buildings 1 1 Depreciated Bldg Value $102,438 $96,484 Depreciated EXFT Valve $1,400 $1,400 Land Value (Market) $26,033 $20.826 Land Value Ag JustlMarket Value "• $129,871 $118,710 PortabilityAdj Save Our Homes Adj $25,265 $16,256 Amendment 1 Adj $0 P&G Adi $0 $0 Assessed Value $104,606 $102,454 I o� Tax Amount without SOH: $1,472.00 2017_Tax Bill Amount $1,163.00 Tax Estimator Save Our domes Savings: $309.00 ' Does NOT INCLUDE Non Ad Valorem Assessments 5.... _....__...... _. ....._. .... ......... ......._.._..__...._....____....................... .. .......... ....._...._....... ......... ........ _ ........ .. ..... _ ...... _. ......... ......... _._ Taxes i Taxing Authority ..... ...... I Assessment Value ............ ......... ........ Exempt Values _... ._ Taxable Value ........ .. j County General Fund .... .............. $104,606 ._.... $50,000 i $54.606 Schools $104,606 $25,000 $79,606 .... .._........ _..__. -.. ..._..._. _............ City Sanford _.- _-........... _.... .......... $104,606 _.. _ ._.. ....... ..... . $50,000 , $54.606 i. _ _......... .............. _ _...._...._ SJWM(Saint Johns Water Management) .._..... . ....... ............... __ $104,606 $50,000 ........ ... ...._..... $54,606 County Bonds _ $104,606 _ $50,000 j _0 $54,606 1 . .. _ Sales .... .. Description Date Book ;Page Amount Qualified Vac/Imp 1 TRUSTEE DEED 6/28/2010 07408 1529 $110,000 : Yes Improved WARRANTY DEED 7/1/1996 03100 0184 $100 . No Improved QUITCLAIM DEED 1011/1995 02975 1712 $100: No Improved ......... ............. ADMINISTRATIVE DEED 1/1/1987 0 821 0850 _..._.. $100 : No Improved ; Firth Comparable Sales Land Method ; Frontage Depth Units Units Price € Land Value 1 ! FRONT FOOT & DEPTH 117,00 115.00 0 $250 00 $26,033 Building Information Year Built Description Fixtures : Bed Bath Base Area i Total SF I Living SF Ext Wall ?Adj Value Rep1 Value ;Appendages Actual/Effective I 1 of 25 4/5/2018, 8:28 AM Billing Address: I Smock, Phillip 2425 Bay Ave Sanford, FL 32771 Ace Air Conditioning, Inc State Lic #CAC1813533 2985 Enterprise Rd. Suite A Debary, FL 32713 Phone: (386) 668-8651 cctNo: 20048320 HVAC Repair / Replacement Proposal Date: Wednesday, April 4, 2018 Ordered By: Phillip Smock Terms: Due On Receipt Department: Debary- HVAC Installation Service / Jobsite Address: Smock, Phillip 2425 Bay Ave Sanford, FL 32771 407-221-2329 Mobile 541682 COLLAR06 6" Tab Collar / Start Collar 2.00 EA $0.00 $0.00 COLLAR07 7" Tab Collar/ Start Collar 2.00 EA $0.00 $0.00 COLLAR08 8" Tab Collar/ Start Collar 4.00 EA $0.00 $0.00 COLLAR09 9" Tab Collar / Start Collar 4.00 EA $0.00 $0.00 COLLARIO 10" Tab Collar / Start Collar 6.00 EA $0.00 $0.00 COLLAR12 12" Tab Collar/ Start Collar 6.00 EA $0.00 $0.00 COLLAR16 16" Tab Collar/ Start Collar 6.00 EA $0.00 $0.00 COLLAR18 18" Tab Collar/ Start Collar 3.00 EA $0.00 $0.00 COLLAR20 20" Tab Collar/ Start Collar 2.00 EA $0.00 $0.00 COPPER38 3/8" Copper Tube 50' O D 1.00 ROLL $0.00 $0.00 Rolled COPPER78 7/8" Copper Tube 50' 0 D 1.00 ROLL $0.00 $0.00 Rolled AFLEX78 7/8" X 1/2" Wall Armaflex Wall 36.00 FT $0.00 $0.00 PVC34 Pvc 3/4" Pipe Sch. 40 10' 5.00 EA $0.00 $0.00 AFLEX118 11/8" X 1/2" Armaflex Wall 12.00 FT $0.00 $0.00 . SS2 3/4" Pvc Float Switch Ss2 1.00 EA $0.00 $0.00 25VNA848AO03 4 Ton Variable Spd H/P 410a 1,00 EA $0.00 $0.00 Carrier 4 Ton Variable Spd H/P 410a FE4ANF005 Carrier/ Bryant 3.0-4.0 Ton Ah 1.00 $0.00 $0.00 Variable Speed R410a/Puron = Evolution/ Infnity System CE090INIO 1Okw Electric Heater 1.00 $0.00 $0.00 SYSTXCCITC01 Carrier Infinity Controller 1.00 EA $0.00 $0.00 Carrier Infinity Controller For Carrier Infinity System With Wif1 CANSTOCK Canstock 11/2" X 10' 2.00 EA $0.00 $0.00 Remit To: / Sub Total: $4,407.68 Ace Air Conditioning, Inc- X Sales Tax: $0.00 2985 Enterprise Rd. Authoriz d Signature Suite A Debary, FL 32713 - Phone: (386) 668-8651 Date l Pr oposal To Fax: (386) 668-7758 Amount: $4 407.68 Page 2 of 2 Printed on Friday, April 6 at 09:58AM by Phillip Smock RECORD COPY c—a Calling for 36,249 BTUH Sheet 1 Add supply in WIC. 20 ", 19.01t ' 12x6 t 139 cfm 8 ", 7.0 fl 16 ", 12.0 ft Garage Use existing supply bcation 10 ", 15.6 ft x 12 for new return. Cfm Cut in new I suppy. , Master i 14 x Boys 14 12", 12.2ff I = 12-, 12.8R 14 x 14 i4X6 272 cfm Y 8x4 48cfm 's 4",9.0R 3_1WIC ' 6 ", 8.6It rt 5 `, 9.4 it mow! , h O lox 6 ,ems � CI r _ - \ 12 x 12 82 dm a�ll x.,:_; I 24xf6 \ � 746 cfm It ', 9.5 (t B ", 4.0 it 126 fr11 9 lox 10 Guest 24 x 18 T 905 cfm `t l 14x6 4.7ft' CL. 215cfm IV,4.3(t `18",29.8f _ !W � \14x6 215 cfm \10",3.5ft �12",21.2it \9",6.tft 3\ 14 x 6 Living 251 cfm B w\LDIA/C Srf- SANF0"R1) R�\� #18-1701 Job #: Phil Smock Scale: 1, 113 -Performed for: Page 1 Right -Suite® Universal 2017 17.0.04 RS000268 Sanford, FL 2018-Mar-27 14:49:53 ons\Owner Builder\Phil Smock.rup fSXKFORD Building & Fire Prevention Division DEPARTMENTResidential Permit Card Pill[O� .e PERMIT NO. I � • 1 47 O S ISSUE DATE: ` `� ' too CONTRACTOR: JOB ADDRESS: — V TYPE OF WORK: w VA C 414, w/ duz*um,,k- Post this permit in a conspicuous location outside • Approved plans must be posted with permit for inspection Leave all work uncovered until inspected and approved Permit ex Tres 6 months from date of issue or last apRroved inspection PROTECT FROM WEATHER BUILDING INSPECTION TYPE APPROVED REJECTED INSPECTOR ELECTRICAL INSPECTION TYPE APPROVED REJECTED INSPECTOR FOOTER INSPECTION ELECTRIC UNDERGROUND STEMWALL FOOTER/SLAB STEEL BOND FORMBOARD SURVEY T.U.G. / PRE POWER SLAB / MONO -SLAB ELECTRIC ROUGH LINTEL / TIE BEAM ELECTRIC FINAL SHEATHING - ROOF MECHANICAL INSPECTION 7TPE APPROVED RFJEC'TED INSPECTOR SHEATHING - WALLS FRAME MECHANICAL ROUGH1-4 INSULATION ROUGH IN MECHANICAL FINAL DRYWALL/SHEETROCK PLUMBING INSPECTION TYPE APPROVED REJECTED INSPECTOR LATH INSPECTION FINAL STUCCO/SIDING UNDERGROUND ROUGH FIREWALL SCREW TUB SET FIREWALL FINAL SEWER INSULATION FINAL PLUMBING FINAL FINAL SFR GAS INSPECTIONS INSPECTION 7TPF_ APPROVED REJECTED INSPECTOR ROOF INSPECTION TYPE APPROVED REJECTED INSPECTOR GAS UNDERGROUND PIPE ROOF DRY -IN GAS ROUGH IN FINAL ROOF GAS FINAL MISCELLANEOUS / FINAL INSPECTIONS INSPECTION TYPE APPROVED REJECTED INSPECTOR INSPECTION TYPE APPROVED REJECTED INSPECTOR FINAL DEMO FINAL DOOR FINAL SOLAR PANELS FINAL WINDOW FINAL POOL SCREEN FINAL SCREEN ROOM FINAL UTILITY BUILDING FINAL BUILDING OTHER MOBILE HOME TIE -DOWN MOBILE HOME FINAL WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT, THERE MAY BE ADDITIONAL RESTRICTIONS APPLICABLE TO THIS PROPERTY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY, AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES OR FEDERAL AGENCIES FBC105.3.3 Inspection Line: 407.792.6069 or 855.541.2112 TO SCHEDULE AN INSPECTION: • Dial 407.792.6069 or 855.541.2112 • Provide the items requested during the message • The type of inspection requested must be scheduled under the appropriate permit type • Follow the prompts *** To Schedule Fire Inspections: Please call 407.562.2786 *** PLEASE NOTE: Inspections scheduled by 5:00 p.m. will be conducted the next business day. If you experience difficulty, please call 407.688.5150 Monday - Thursday 7:30 am - 5:30 pm for assistance. AUTOMATED INSPECTION SYSTEM CODES BUILDING ELECTRICAL FOOTER 104 ELECTRIC UNDERGROUND 211 STEMWALL 102 FOOTER / SLAB STEEL BOND 221 FORMBOARD SURVEY 147 T.U.G. 216 SLAB / MONO -SLAB 103 PRE POWER FINAL 218 LINTEL / TIE BEAM 105 ELECTRIC ROUGH 212 SHEATHING - ROOF 106 ELECTRIC FINAL 213 MECHANICAL SHEATHING - WALLS 115 FRAME 109 MECHANICAL ROUGH 409 INSULATION ROUGH -IN 110 MECHANICAL FINAL 410 PLUMBING DRYWALL / SHEETROCK 131 LATH INSPECTION 132 UNDERGROUND ROUGH 322 FINAL STUCCO / SIDING 130 TUB SET 312 FIREWALL SCREW 120 SEWER 311 FIREWALL FINAL 143 PLUMBING FINAL 313 GAS INSULATION FINAL 113 FINAL SFR 138 GAS PIPING UNDERGROUND GAS ROUGH -IN 328 314 ROOF ROOF DRY -IN 116 GAS FINAL 315 FINAL ROOF III MISCELLANEOUS / FINAL INSPECTIONS FINAL DEMO 126 FINAL DOOR 136 FINAL SOLAR PANELS 134 FINAL WINDOW 137 FINAL POOL SCREEN 139 FINAL SCREEN STRUCTURE 127 FINAL UTILITY BUILDING 124 FINAL BUILDING - OTHER 112 MOBILE HOME TIE -DOWN 145 MOBILE HOME BUILDING FINAL 146 Miscellaneous Notes: REVISED: 4-17 Inspection Line: 407.792.6069 or 855.541.2112 SITE COPY E Add supply in WIC. 20 ". 19.0 it Calling for 36,249 BTUH 116 -, 12.0 it Garage Job #: Phil Smock Performed for: Sanford, FL Sheet I Use existing supply location M 15.6 it x Q for new return. 3 cf. Cut In new supply. Master Boys 14 x 14 2' i 12 12.2 if fill 1 2 1' i4x 14 14 x 6 272 cfm 8x4 i m 48 cfm 10 13.3 it 4 9.0 it WIC 61 86ft S' 94ft loxi -6 (D cf P \12x 12 P2 cfm 6 all CL, 24x18,... 4 x M 746 cfm 12 X 6 M crm 9.6 ft 8 4.0 It \ 12 x 6 123 cfm mg1 lox 10 Guest 8 7.0 it 24 x 18 T 905 cfm 1829.8 14 x 6 16 4J it 215 cfm 9* 43(t 14 x 6 215cfm 3.5 it 12 ", 2t.2 it It 14 x 6 Living 251 rim 0 S A N F C .12, nt JA P� 7 Scale: 1: 113 Page I Right -Suite® Universal 2017 17.0.04 RS000268 2018-Mar-27 14:49:53 ... onslOwner BuildeAPWI Smock.rup