Loading...
HomeMy WebLinkAbout245 Big Spring TerCITY OF SANFC[@[@ BUILDING & FIRE PREVENTiUN Q� PERMIT APPLICATION APR 13 20�� Application No: / BY: 1 ocumented Construction Value: $ Job Address: 245 Big Spring Terrace Historic District: Yes ❑ No ❑ Parcel ID: OCQ0 1100 Residential V3 Commercial ❑ Type of Work: New ❑ Addition ❑ Alteration Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: 'T_n aQ 1 Q-{- on Cky0 —Yl' k ly)�P Plan Review Contact Person: j C M `G Title:jY i�� YYIi ax) Phone: Ooz�l 1p - oo?)l Fax: Email: MCr,(a� ,+fSo . Ooyn Property Owner Information Name Jeannelle Beaubrun-Soomer Phone: 6178992458 Street: 245 Big Spring Terrace Resident of property? City, State Zip: Sanford, FL 32771 SoCl 1 N Contractor Information I � Name Tesla Energy Operations, Inc. Phone: 702-716-0084 Street: 8500 Parkline Blvd Ste 100 Fax: City, State Zip: Orlando, FL 32809 State License No.: EC13006226 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51' Edition (2014) Florida Building Codk Revised: June 30, 2015 Permit Application S NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that ma,, found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. S ture of Owner/Agent Date Jeannelle Beaubrun-Soomer Print Owner/Agent's Name Signature t o�R nre o£F i at 9Z9001 33 # u01ss1wwo3 BIN -Cl unr sai1dx3 *ww03 6yy °; r= epli0lJ 10 alelS • 011Qnd !l3HSI3 'S 0 VHOIN ";a�, tl+ Owner/ ��,.• or Produced ID Type of ID A 411 AA 4 /1A Signature of Contractor/AgeniV ate Print Contractor/Agent's 14ame Signature ofNota -Stje of Florida Date KASEY TAYLOR State of Florida -Notary Public =► •c Commission # GG 149323 My Commission Expires October 08, 2021 Produced ID Type of to Me or BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing[] Gas ❑ Roof ❑ Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads Fire Alarm Permit: Yes ❑ No ❑ APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: Sr 4 • rl • t8 COMMENTS: Revised: June 30, 2015 Permit Application REQUMED INSF ECTION' SEQUENCIE' lspg 15', - V -1,ikQL Addirens: LWAM ruspecdon Dese on. Eaa. ooter / Setback 'Remwall Fbi-indaticry. / Prwm RnarrT.'R'Tlr%7F-xr Slab /16-ono Slab-Pkepour Lintel / Tie Beam / FM Down Cell Sheathing— WaUs- Sheathing— Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection 1. Final Solar Final Roof Final Stuccol Siding Insulation Final Final Utility Building - Final Door Final Window - Final Screen.Room Final. Pool Screen Enclosure Mobile Home Building Final Pre -Demo Final Demo. Fihal Single F-anuffy-Reddencet Final. Building. (Other) max j ]funsclflon.Descrl2flon Electric. Underground I Footer /' Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final Min Max Hns2ectiolm as n Plumbing Underground Plumbing Sewer Plumbing Tub, Set Plumbing Final ..... ........ ... -Mechanical _�.ough I Mechanical. Final 60 derground Gas Rough REVISED: June 2014 THIS INSTRUMENT PREPARED BY: Name: rlo Erica McCurdy Address: ar ine v to an a, NOTICE OF COMMENCEMENT State of Florida County of Seminole ! 1�1111 i11i11#II �llf� � 1 111 loll WHITMALOYr 1ENINIBLE CU lf� CI...ERK OF' CIRCUIT COURT MLLER BI( 9110 Ps 1181 (1F`ss) CLERK'S 4 20/8040622 RECORDED 04/13/2011 li ,:40--2;. All RECORDING FEES $10,00 RECORDED BY hdevore Permit Number: Parcel ID Number: 71- 1 "i 01 / � u- 00Q7 - ( I oc) The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) 1r1� IQ -�\r)nu % -79 ?&5 43 4n 4-5 245 Big Spring Terrace GENERAL DESCRIPTION OF IMPROVEMENT: f�1S-4 g I W-k�nn o`i no'i -Yl' our- >? Gibn (AF )(A+rj tc (II-1 IS-I-P OWNER INFORMATION: Name: Jeannelle Beaubrun-Soomer Address: 245 Big Spring Terrace Sanford, FL 32771 Fee Simple Title Holder (if other than owner) Name: CONTRACTOR: Name: Tesla Energy Operations, Inc. Address: 8500 Parkline Blvd Ste 100 Orlando, FL 32809 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: In addition to himself, Owner Designates To receive a copy of the. Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of myknglwledge and belief. t� Jeannelle Beaubrun-Soomer 1 Owners Signature Owners Printed Name Florida Statute 713.13(1)(g): " The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead." State of F),0YrD%) County of em )r10 � The foregoing instrument was acknowledged before me this day of IQ a N' , 20 C' by �c-C c Y1 /�P' �e fi-b t Pf VJ1 — J(j0M e ✓ Who is personally known to me Name of person making statement t OR h o c f n 'fic do t e f entification produced: dwP „lb ?o� RICHARD S. FISHER` .t �;.t,' c Notary Public - State of Florida N,+� :o, My,Comm. Expires Jun 13. 2018 ' ado e'�. �or•' Commission a FF 100626 N ery Signature M" DocuSign Envelope ID: 85 K This disclosure is designed to help�you-'understand the key terms of your purchase of a, It is not a substitute;for your purchaise contract ('Contract"), loan or any other documentt Information -presented below is `subject to the terms of your Contract.- Read allf,documents carefully so you fully understand the transaction. For.more information ori'becom"ing a smart solar consumer please vish'www.seia.org/co To'better understand the cost of the electricity produced by your System, please refer to SETA® Solar Purchase Disclosure Addendum — Estimated Cost Per kWh. Provider:=Testa; `Inc. Address: 3500 Deer Greek Road Palo Alto, CA 94304 Tel.: 888-518-3752 License # (if applicable): Not Applicable Email: customercare@tesla.com Purchase Price Your purchase price: $26,61.7.50 List of any credits incentives or r *NOTE: Not everyone is eligi Payment Sc Amount you o Amount you o 0 Amount you o Your financinc le Installer: Tesla Energy Operations.lr, Address: 3055 Clearview Way San Mateo, CA 94402 Tel.: 888-765-2489 State/County°Contractor License #: FL EC13006226 Email: customercare@tesla.com m"). this e separate form, >Customer: Jeanneile Beaubrun- Soomer System Installation; Address: 245 Big Spring Terrace, Sanford, FL 32771 Customer Mailing Address: 245 Big Spring Terrace, Sanford, FL 32771 Email asoomer@gmail.corn�"��, Contract Date: 3/30/2018t- EW in the above purchase price: $0.00 or rebates or can rider at Contract signing: $0.00 Cider at the commencement of installation: $0,00' cider at the completion of installation: $0.00 r will make the final payment to the Provider after Financing Your system: WILL be financed NOTE: If your System is financed, carefully read statement does not contain the terms of your arrangement, contact your finance provider and r Installation Timing Approximate Start Date: 60-120 d Approximate Completion Date: 6C Interconnection Approval, PROVIDER is Solar Purchase Discl 3182697 following amount: $26,617.50 ments and/or disclosure forms provided by your lender. This agreement. If you have any questions about your financing incing disclosures before signing a Contract. 1 1. date the Agreement is signed. Im the dateof the Agreement is signed. interconnection application. A. 1-1i DocuSign Envelope ID: Site & Design Assurrlp� The estimated size of your Estimated gross annual,elE Estimated System Lifetime Estimated annual 016ttricit, System location on your pr Con"MHN I I The Sy§t m At,,the time of installatiqq,,) b 'A such credit are,set by yc lZ r- $89D-AACO-E74373708185 1,4 ns,4 r your Purchase fstem 1 8.19 kW;; DC "icity pro, ud ion,in"kilowatt-hours qLy cars reduction decrease due to natun erty, "rooftop -L`be" connected to the electric g ,�,,Jocal utility WILL credit you for jurisdiction. ce & Repairs IS included for 20 years from the Instalk Lei Shade, Management: Shading on your solar display dramatically reduces "electricity production, Keep trees or other tall plants trimmed to prevent shade on your system. Panel Cleaning: Cleaning your panels of debris can improve your system performance. Flushing the panels from the ground with a water hose can let more,tunlight penetrate through the glass cover. "System repairs" refers to actions needed to fix your System if it is malfunctioning. System repairs ARE provided ,by the Installer. If System repairs ARE included, the coverac Inverter Warranty: 20 years Please check the Manufacturer's warranty -,ft, If System repairs ARE years) are: Solar System: 20 year Please review your,Cc 11 106 OM Note that equip At in subcontract any of its i requests. hardware component of your System (in years-) are: of other hardware components. bor/workmanship for each component" Systprnp,(in tract ,for.",taditich'alJhformation about any warranties on the System`installdtidhand equipment. rrantiesbardware,�are not required to include labor/workmanship. Your Provider mayassignor , �-,p-q,- lhts or obligations under this Agreement to any affiliate,'successorartner(O , rchaser. If such a oa"7,ndtifildd if this will change the address or phone" number to use -for system, maintenance or Warranty.%4 0 Dof IS warranted against leaks from the system installation for th 1,fijrst 10 years the he Provider. 7l ,e Perf f ffi",", hce or Production Guarantee Provider is providing you with a: • Performance guarantee for 20 years • System production guarantee for 20 yo Underperformance or underproduction will be part and restore System performance. If at,th( monthly payment the cumulative ActujIXWK'4 we will send you a refund check equal, to Guaranteed kWh multiplied by thg� GuairaMee Taxes You are responsible for may result from enterin( Solar Purchase Disclosure 201 3182697 pia "O� !d as follows: Tesla will repair or replace any defective each successive 24 month anniversary of your firstg,,,,, d by the System is less than the Guaranteed kWh`, —the &',between the cumulative Actual kWh and4he^ per kWh. you own. Consult a tax professional to DocuSign Envelope ID: Utility and Electricity Usal You HAVE been provided with If provided, the savings,estlma net metering value and°`thede codes, location, system size, c the based on your r ased on: Estima , which can be a and local utility i r system will Iast.30!years;ti' M important to -understand that electricity rates are estimates onl increases may vary. iider IS NOT. baranteeing these savings. Cooling t'ffkPeHod/ Right to Cancel In addition to any rights you have under state or local law, you HAVE the right to terminate this agreement without penalty within three (3) business days of 3/30/2018 by notifying Provider in writing at the above address. /4\1 SETA Solar Business Code Provider DOES abide by and agrees to be, For more information about the SETA Solar http://www.seia.org/consqmers Additional DisclosU or Terms Customer's Initials here help, addendum is action. Solar Business Code and its complaint resolution Ind complaint resolution process, please visit ESTIMATED COST PER kWh eplace, t1i SEIA® Solar Purchase Disclosure, It provide nerav system (Svstem) over the life of the Svstem. for your purchase contract, loan or any other documents Information presentbb below is subject to the terms of your purchase contract. Read,all documents carefully so you fully understand the transaction: For,more information on becoming a smart solar consumer please visitwww.sE Provider: Tesla,"Inc. Installer:' Tesla Energy Operations, Address: 3500 Deer Creek Road Inc. Palo Alto, CA 94304 Address:w3055 Clearview Way Tel.: 888-518-3752 San Mateo; CA 94402 License # (if applicable): Not Tel.: 888-765.2489 Applicable State/CountyOContractor License #: Email: customercare@tesla.cofii FLC'93006226 2.x. . Email.-customercare@tesla.com System Charac Solar Purchase Disclosun 3182697 Customer: Jeannelle Beaubrun- Soomer System Installation Address: ° 245 Big Spring Terrace, Sanford, FL 32771 Customer Mailing Address,: 245 Big Spring Terrace, Sanford, FL 32771 Email: asoomer@gmall c m"° Contract Date 3/3012018z', JIR,�',-� ._ _& DocuSign Envelope The pricing in this Solar don't sign this Solar Hor 3/3012018, Tesla resery agree to our then currer This Change Order sh, it 1s rn writing and sigr ,Min,, Order: This Change n Improvement, Agreement Change Order is valid for 30 days rovement'Agreement"Change Order and return it to us on or ,ight toxreJ' ct this Solar Home improvement Agreement Char ncorporated into the Agreement and shall become"part c the parties prior to the commencement ofany work, covi ipersedes any prior change order. y,„ Customer's Name: Jeannelle Beaubrun-Soomer DocuSigneo by: Signature: ' btAa I( AIS06MI V Date: 4/10/2018 Customer's Name: Signature Date: Solar Home 3182697 greement only if this Change Solar Home ilmprovement Agreement Tesla: Approved Cal Yankton VP, Energy Sales and Operations rll Date: 3/30/2018 - 1,2018 RECORD COPY Version #72.1 - TBD RU Ed Generated March 29, 2018 RE: CERTIFICATION LETTER SANFORD BUILDING DIVISION Project/Job # 327511 Project Address: Soomer Residence A PERMIT ISSUED SHALL BE CONSTRUED TO BE A 245 Big Spring Terrace LICENSE TO PROCEED WITH THE WORK AND NOT AS Sanford, FL 32771 AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL AHJ City of Sanford CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT SC Office Orlando THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, Design Criteria: CONSTRUCTION OR VIOLATIONS OF THIS CODE Applicable Codes = 2017 Florida Building Code (6th Edition) / IEBC, ASCE 7-10, and 2012 NDS Risk Category = II Wind Speed = 135 mph, Exposure Category C, Partially/Fully Enclosed Method Ground/Roof Snow Load = 0 psf - MP3A: 2x4 @ 24" OC, Roof DL = 6.5 psf, Roof LL = 18 psf f - REVIEWED FOR CODE COMPLIANCE - MP38. 2x4 @ 24 OC, Roof DL = 6.5 ps ,R oo - ps - MP4: 2x4 @ 24" OC, Roof DL = 6.5 psf, Roof LL = 18 psf - MP5: 2x4 @ 24" OC, Roof DL = 6.5 psf, Roof LL = 18 psf PLA S EXAMINER DATE Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.09945 < 0.4g and Seismic Design Category (SDC) = A < D To Whom It May Concern, Ajobsite survey of the existing framing system of the address indicated above was performed by a site survey team from Tesla. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the alteration to the existing structure by installation of the PV system, with upgrades specified in the plans, meets the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Sincerely, Humphrey Kariuki, P.E. Professional Engineer T:443.451.3515 email: hkariuki@tesla.com Digitally signed by Humphrey Kariuki Date: 2018.03.29 22:39:51-04'00' ��a�ttlirrf�jr1 KAId,/q f,. Jam.•' . G 2 : No. 81 20 ED STATE OF40R1QN f 1ONA1- 1 8 — 1 7 w 2 Tesla, Inc. T S 5 l.. n Version #72.1 - TBD RU Ed Generated HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware '- Hardware - Landscape Mod les'Standoff Specifications X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP3A 72" 24" 41" NA Staggered 67.6% MP3B 72" 24" 41" NA Staggered 67.6% MP4 72" 24" 41" NA Staggered 67.6% MPS 72" 24" 41" NA Staggered 67.6% Portrait Hardware -'Hardware - Portrait Modules' Standoff S ecifications X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP3A 48" 21" 62" NA Staggered 68.2% MP36 48" 21" 62" NA Staggered 68.2% MP4 48" 21" 62" NA Staggered 68.2% MP5 48" 21" 62" NA Staggered 68.2% Mounting Plane Structure Information Qualification Results Type Pitch Spacing Member Evaluation Results MP3A Pre -Fab Truss 27° 24" O.C. Member Impact Check OK MP3B Pre -Fab Truss 27° 24" O.C. Member Impact Check OK MP4 Pre -Fab Truss 27° 24" O.C. Member Impact Check OK MPS Pre -Fab Truss 27° 24" O.C. Member Impact Check OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site. The existing gravity and lateral load carrying members were evaluated in accordance with the IEBC and the IBC. Tesla, Inc. T = 5 L n �- ��t.r� y ,ct C12, S ,0 E3c 10 JSTRUCTURE' ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP3A` Member Properties Summary MP3A Horizontal--MembecSpans < Rafter Properties Overhang 1.16 ft Actual W 1.50" Roof System Properties " Span 1 „" 7.71 ft ._' Actual D 3.50" Number of Spans w/o Overhang) 1 Span 2 Nominal Yes Roofin Material':,-• -�,w, r�'; Comp;Roof,;;, Span3 5.25 Re -Roof No San 4 Sx(in .A3 3.06 Plywood. Sheathin Yes_ S an.5 Ix in^4 5.36 Board Sheathing None Total Rake Span 9.96 ft TL Defl'n Limit 120 Vaulted Ceiling': _" No _ PV 1 Start #'' 1.25 ft Wood S ecies SPF Ceiling Finish 1/2" Gypsum Board PV 1 End 7.58 ft Wood Grade #2 Rafter Slo a s Rafter Spacing 24" O.C. PV 2 End Fv(psi) 135 To LatBracin Fully PV 3 Start E (psi) 1,400,000 Bot Lat Bracing At Supports PV 3 End E-minpsi) 510,000 'Member Loading Summary Roof Pitch4 6/12 .1 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 6.5 psf x 1.12 7.3 psf 7.3 psf PV Dead Load PV-DL 3.0`psf x 1.12 3.4 psf Roof Live Load RLL 20.0 psf x 0.90 18.0 psf Live/show Load. LUSL1' a, Total Load(Governing LC TL 25.3 psf 10.7 psf Notes: 1. ps = Cs'pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (Ct) (Is) p9 ; Ce 0.9, Ct=1.1, Is=1.0 Member Analysis Results Summary Governing Analysis Pre-PV Load s Post-PV` Net Impact Result Gravity Loading Check 25.3 10.7 -58% Pass �ZEP HARDWARE,`D`ESIGN CALCULATIONS�FMP3A .,.�„ � � �' PV Mount SRV Wiiiid.Desi n C`riteria r, Design Code IBC 2015 ASCE 7 10 Wmd Desjgn.Method , .w artially/Fully Enclosadm Method „. . Ultimate Wind Speed V-Ult 135 mph Fig 1609A 4, Roof Style Gable Roof Fig 30 4 2A/B/C 5A/B Mean Roof— Hei ht „m h.. 25 ft Sectioh 26 2 Wind Pressure::Calculation Coefficients ,-" Wind Pressure Exposure KZ 0.95 Table 30 3 1 Topographic,Factor K�, ;. 1 00 Section 26 8 Wind Directionality Factor Kd 0.85 Section 26.6 1 Im ortanee Factor I NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V12) Equation 30.3-1 37.5 sf Ext. Pressure Coefficient U GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext::Pressure'Coefficient Down ' GC Down), ;- 045 >. „- .. �.._ -------- Fig.304-2wB/C=5A/B' Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Rressure.0 p`„ -32.8 psf: Wind Pressure Down � ` �, �_` � aowo � � � � 16.9 sf �A►LLOWABLE STANDOFF SPACINGS.��_.��_..� .��.�_.� r.�,.��.�� ...�'.__�_ __�.a.x._.r ._ _ .._��.,.�.- .wx� �. � �,�_ ��.�,_� ���� ST�RUCTUREy,ANALYSIS -LOADING SUMMARY AND MEMBER CHECK_- MP3B�-�_��� Member Properties Summary MP36Y Horizontal, Member Spans ,Rafter, Properties;, Overhang 1.16 ft Actual W 1.50" ;. Roof S. stem Properties ; . Span .1, 7.44,ft- - ; , Actua[!), . Number of Spans w/o Overhang) 2 Span 2 7.37 ft Nominal Yes Roofing Material- Comp Roof Span 3_ _ A=(in^2).;5.25 .. Re -Roof No San 4 Sx in.113 3.06 PI wood Sheathing Yes . San 5', bt in"4 5.36 Board Sheathing None Total Rake Span 17.92 ft TL DOM Limit 120 Vaulted Ceiling No PV 1 Start `8.25 ft._' Woo`d Species SPF Ceilina Finish 1/2" Gypsum Board PV 1 End 14.58 ft Wood Grade #2 Rafter Slope ,' 27° PV 2 Stain Fb" si : 875 Rafter Spacing 24" O.C. PV 2 End Fv (psi)135 To ` LatBracin Full' PV3Start E' si1;400;000" Bot Lat BracingAt Supports PV 3 End I E-min(psi) 510,000 Member Loading Summary Roof Pitch-. =`. ;, -. 5/12 = ,Initial Pitch Ad'ust Non-PV Areas PV-Areas ' Roof Dead Load DL 6.5 psf x 1.12 7.3 psf 7.3 psf PV.Dead Load 'PV-DL 3.0 psf: x 1.12 _ 3.4psf - Roof Live Load RLL 20.0 psf x 0.90 18.0 psf Live/Snow Load LUSL? Total Load(Governing LC TL 25.3 psf 10.7 psf Notes: 1. ps = Cs'pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (Ct) (IS) p9 ; Ce 0.9, Ct=1.1, IS=1.0 .. Member Analysis.,Results.Suminary.=.`. =� Governing Anal'sis Pre-PV Load s Post-PV Net Impact Result Gravi Loading Check 1 25.3 1 10.7 -58% Pass ZtF HARDWARE-- DESIGN CALCULATIONS -- MP3B Mounting Plane Information Roofing Material Comp Roof, Roof Slope 27' Framin T e /Direction TY Rafters PV S stem T e Y YP SolarCity SleekMountTm _ ZepSystem Type _ _ _._ _ ZS Comp- _ Standoff Attachment Hardware Comp Mount SRV Spanning Vents No Wind Design Criteria -' Design Code IBC 2015 ASCE 7 10 _w ,_ Wind Design MethodPartially/Fully�Enclosed �. Method o Ultimate Wind Speed V Ult 135 mph Fig. 1609A yExposure Category C7777 _ Section 26J Roof Style Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof,,Hei ht .:,..: :.7. ;. h. "' 7 r; , Section 26:2 Wind Pressure Calculation Coefficients -._- Wind Pressure Exposure KZ 0.95 Table 30.3-1 Topograpliic Factor �. Kn LL _ q 1 00 F� Section 26:8 Wind Directionality Factor Kd q e 0.85 Section 26.6-1 lm 'ortance Factor I NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V-2) Equation 30.3-1 37.5 psf Wind Pressure Ext. Pressure Coefficient U GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext:>Pressure Coefficient'(Down ;:.; ..GCp•(Down) �. . ,,` . �,"0.45 ,,,. r , �, �., . ;. ° , .,. ,Fig. 30.4 2A/BIQ=We Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure Up p -32.8 psf Wind Pressure Down down 16.9 p§f . . ' Member Propqrtles Summary Roof S�stem Properties Span 1 7�55 ft Actual D, _3.50�­ Number of Sp;—ns (w/o Overhang) 2 Span 2 7.33 ft Nominal Yes Roofing Material Cornp Roof Span 3 Plywood Sheathing Yes Span 6 IX (16A 4)--- 5.36 Board Sheathing None Total Rake Span 18.00 ft TL DOM Limit 120 Vaulted Ceiling-.- No - --,,PV 1- Start, 0.67 ft Wood Species SPF: Ceiling Finish 1/2" Gypsum Board PV 1 End 10.17 ft Wood Grade #2 Roof Pitch Initial Pitch Adjust F Non-PV Areas PV Areas P.V Dead Load Wember-AnalysivResbits Summary Post-'PV Net lmpact� Result' Gravity Loading Check 25.3 1 10.7 -58% Pass --ly-HARDWARE DESIGN CALCULATIONS MP4 Mounting, Plane Information F�oofing-Material'�`,--': Comp Roof,,-, Roof Slope 27° F �am Lin'j,-f Direction - -7 Rafters` 77777-7 �Y-'Y fters 7",7, PV System Type SolarCity SleekMountTM omb 7 7 Standoff (Attachment Hardware) Comp Mount SRV S02�hniqg enLs J, No 4X Wind Design Criteria Design Code IBC 2015 ASCE 7-10 Wind q —M -- Partially/Fully Enclosed Metjc d Ultimate Wind Speed V-Ult 135 mph Fig. 1609A Exposure Cateqqr �y ____Section 26 7 Gable Roof Fig. 30.4-2A/B/C-5A/B 7—h 25 ff --:— Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure K, 0.95 Table 30.3-1-- qgr@p�ic Factor lop4.w�msvn� Wind Directionality Factor Kd- 0& 0.85 7 Se ion 26.8 Section Section 26.6-1 Factor, NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 37.5 psf Equation 30.3-1 I - - Wind Pressure- Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient (Down) 0.45, Fig. 30-4 -2A/B/C-5A/B Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure Up P(.P) -32.8 psf Wind Pressure Down P(down) 16.9 psf . ' . . ' —'-'--''------'--'--'''-'------------'---'--------''--' - ---- - ' Roof System Properties -Span 1 Number of Spans (w/o Overhang) 5 Span 2 1.99 ft Nominal Yes eS Board Sheathing None Total Rake Span 17.79 ft TL Defl'n Limit 120 Vaulted Ceiling No, PV I -Start 1- 3.42 ft Wood Species SPF - Ceiling Finish 1/2" Gypsum Board PV 1 End 9.75 ft Wood Grade #2 Loading Summary,,,. Roof Pitch PV Areas PV, Dead -Load Gravity Loading Check 25.3 10.7 -58% Pass �ZEP HARDWARE DESIGN CALCULATIONS.:: MP5 Mounting Plane Information, Roofing Material ComprRoot Roof Slope 27' —te F raMin 'TY 6 Direction Y3 �f PV System Type SolarCity SleekMountTm —p System 7ZS Comp Standoff (Attachment Hardware) Comp Mount SRV Wind Design Criteria°°; Design Code IBC 2015 ASCE 7-10 jj� Design Method_Partially%Fully Enclosed Method Ultimate Wind Speed V-Ult 135 mph Fig. 1609A Ex P91k49k _Sects 26.7 Roof Style Gable Roof Fig. 0.4- -5A/ ,Mean'Roof Height 2,: Section 26- I Wind Pressure Calculation Coefficients Wind Pressure Exposure K, 0.95 Table 30.3-1 T9p.9g!@pALC Z-7 j 760 Section 26 Wind Directionality Factor K, 0.85 Section 26.6-1 Wortan-ce Factor INA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V-2) Equation 30.3-1 37.5 psf Wind Pressure L Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext. 'P.'re'siureCoefficient. Down GCp (Down) -,,,445 Fig. 30.4 -2A/6/C-5A/ B Design Wind Pressure P p = qh (GCp) Equation 30.4-1 Wind Pressure Up plup) -32.8 psf Wind Pressure Down P(down) 16.9 psf -7- ALLOWABLE - -STANDOFF '91"ACI W-9---r 7 ABBREVIATIONS ELECTRICAL NOTES I JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONIC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET —BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT LICENSE MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: City of Sanford UTILITY: Florida Power and Light CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN MA10LE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION MATH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER —CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY —RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(8). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH THE 2017 FLORIDA BUILDING CODE (6TH EDITION). 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE. JOB NUMBER J B-3 2 7 511 00 MOUNTING SYSTEM: ZS Como V4 w Flashing —Insert (26) SolarCity#SC31582 INVERTER: SOLAREDGE # SE760OH—USOOOSNU2 EV ANDERSON SOOMER 245 BIG SPRING TERRACE SANFORD, FL 32771 VICINITY MAP I INDEX Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS Sheet 4 UPLIFT CALCULATIONS ' Sheet 5 THREE LINE DIAGRAM X Cutsheets Attached I � I ` A REV BY DATE COMMENTS W 1st St )laitalGlobe. U.S. Geoloaical Survev ®�.�� 8.19 KW PV ARRAY PAGE NAME: COVER SHEET Roberto Gurrusquieto Quezad SHEET: REM: DATE- 1 3/29/2018 T=SLn 245 Big Spring Terrace 1��1(E) DRFVEWAY .;•5'�.Front Of House i 11 CHANGE f I� \\`II111111j� / KANiq..... �%GE N SSr .G -:Z • No 8120 -_ PITCH: 27 ARRAY PITCH: 27 * MP3 AZIMUTH: 90 ARRAY AZIMUTH: 90 — MATERIAL: Comp Shingle STORY: 2 Stories STATE OF !V�\ PITCH: 27 ARRAY PITCH: 27 MP4 AZIMUTH:270 ARRAY AZIMUTH:270 t� tORIa MATERIAL: Comp Shingle STORY: 2 Stories SS /ONAL �C,\`\ PITCH: 27 ARRAY PITCH: 27 AZIMUTH:180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories Digitally signed by Humphrey Kariuki Date: 2018.03.29 22:41:47 I FGFND (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS © AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS M DISTRIBUTION PANEL & LABELS F LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER RSO RAPID SHUTDOWN O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE O HEAT PRODUCING VENTS ARE RED 1 INTERIOR EQUIPMENT IS DASHED L ='J SITE PLAN N Scale:1/16" = 1' w E 01, 16' 32' S CONFIDENTIAL — THE INFORMATION HEREIN SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WTH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERIAISSION OF TESTA INC. JOB NUMBER J B-3 2 7 511 00 CUSMER DESCRIPTION. ANDERSON SOOMER 8.19 KW PV ARRAY 245 BIG SPRING TERRACE SANFORD, FL 32771 PAGE NAME SITE PLAN DESIGN:CONTAINED Roberto Gurrusquieta Quezad 1 T = 5 L n MOUNTING SYSTEM: ZS Comp V4 wFlashing—Insert MODULES: (26) SolarCity#SC315B2 SHEEP. Wt. DATE 1 2 3/29/2018 IMUTER: SOLAREDGE # SE760OH—USOOOSNU2 • -D4 SIDE VIEW OF M13B NTS MP36 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" 41" 0" STAGGERED PORTRAIT 48" 21" 62" 0" TOP CHORD 2X4 @ 24" OC BOT CHORD 2x4 @24" OC ROOF AZI ARRAY AZI 90 PITCH 27 STORIES: 2 90 PITCH 27 Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. n SIDE VIEW OF MP4 NTS MP4 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" 41" 0" STAGGERED PORTRAIT 48" 21" 62" 0" TOP CHORD 2X4 @ 24 OC BOT CHORD 2X4 @24" OC ROOF AZI ARRAY AZI 270 PITCH 27 STORIES: 2 270 PITCH 27 Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION. EXCEPT IN CONNECTION MATH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, IWTHOUT THE WRITTEN PERMISSION OF TESLA INC. .W NUMEER: J B- 3 2 7 511 00 MOUNTNG SYSTEM: ZS Coma V4 w Flashina—Insert 1582 INIARTER: SOLAREDGE # SE760OH—USOOOSNU2 `���IIIIIIrr�/' 0 ENS _ No. 8120 ; 3 ��� � 0 . STATE OF • .FLOR4DP..•' ��: �'SS��NA>` E�.• ��7�rrrIII11���� ANDERSON SOOMER 245 BIG SPRING TERRACE SANFORD, FL 32771 CC-)_ SIDE VIEW OF MP3A NTS MP3A X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" 411' Oil STAGGERED PORTRAIT 48" 21" 62" 0" TOP CHORD 20 @ 24 OC BOT CHORD 2X4 @24" OC ROOF AZI ARRAY AZI 90 PITCH 27 STORIES: 2 90 PITCH 27 Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP MOUNTING BLOCK ZEP FLASHING INSERT (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG SCREW LI (2-1/2" EMBED, MIN) (E) RAFTER DESCRIPTION: 8.19 KW PV ARRAY PAGE NAVE STRUCTURAL VIEWS INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. ATTACH FLASHING INSERT TO (2) MOUNTING BLOCK AND ATTACH TO RAFTER USING LAG SCREW. INJECT SEALANT INTO FLASHING (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE ROOF PENETRATION. INSTALL LEVELING FOOT ON TOP (4) OF MOUNTING BLOCK & SECURELY FASTEN WITH BOLT. DESIGN: Roberto Gurrusquieta Quez SHEEP. REV.. DATE 3 3/29/2018 T=SLn CF�- SIDE VIEW OF MP5 NTS MP5 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" 41" 01. STAGGERED PORTRAIT 48" 21" 62" 0" TOP CHORD 2x4 @ 24" OC BOT CHORD 2x4 !7a 24" OC ROOF AZI ARRAY AZI I 180 PITCH 27 STORIES: 2 180 PITCH 27 Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. (E) 2x4 THIS STRUCTURE WILL RECEIVE A BLOCKING UPGRADE. (N) STANDOFF SHALL LAG DIRECTLY INTO (N) BLOCKING (N) 2x6 DF#2 OR SPF#2 BLOCKING. (E) JACK TRUSS OR RAFTER (BLOCKING NOT REQUIRED DOWN HERE) (N) SIMPSON A34 CUPS (2 PER BLOCK) W/ (8) 8d (0.131") X 1-1/2" NAILS PER CLIP (E) SHORTEST BOX TRUSS (BLOCKING FROM HERE UP TO RIDGE AS NEEDED) INSTALLATION NOTES: 1. CUT (N) BLOCKING TO FIT TIGHT BETWEEN (E) TRUSSES AND KEEP FLUSH TO ROOF SHEATHING. ENSURE THERE ARE NO GAPS BETWEEN MEMBERS. 2. INSTALL (N) BLOCKING WITH TWO A34 CLIPS, ONE AT EACH END OF BLOCKING. 3. NAIL A34 CLIPS TO EXISTING RAFTERS WITH (8) 8D (0.131") X 1.5" NAILS, FILLING ALL HOLES. ENSURE ALL NAILS ARE LOCATED AWAY FROM EDGE OF MEMBERS TO AVOID SPLITTING WOOD. * INSTALL BLOCKING ONLY BELOW STANDOFF LOCATIONS. NEW BLOCKING SIDE VIEW V -)j Scale: 1/2" = 1' �����wlllrri<<i KANi.4 ' Q�.••. ��CENSF'•.��G� No.8120 �� STATE OF C(� '•.FCORIOP.•' GN /ONAt_ '�IJIl111�� CONFIDENTIAL - THE INFORMATION HEREIN CONTATED HALLANYONOT BE E USED TESLTHENOR SHALL IT BE DISCLOSED IN MOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESIa INC. joB NUMEER: J B-3 2 7 511 O O CUSTOMER DESCRIPTION. ANDERSON SOOMER 8.19 KW PV ARRAY 245 BIG SPRING TERRACE SANFORD, FL 32771 PAGE NAME. PAGE STRUCTURAL VIEWS DESIGN. Roberto Gurrusquieta Quezad T 1 5 L n MOUNTING srslEM ZS Comp V4 w Flashing —Insert uoouu;s (26) SolarCity#SC315B2 SHEEP: REV DAIS 3/29/2018 NOS' SOLAREDGE SE7600H—USOOOSNU2 SEE SEPARATE PACKET FOR 5TRL CTIMAL CALCULATK I& mdw NrIR "- tfi-i1�6.. Affl +a►Aw vim *elm N" PR'. 4m a om*,*m mwm.dft w mar x> Wftgmd `ftmiiiiiiin Ns AZ *111M NL4 I� NO NE ! N l E N9 lN1N< � m011 Wrl NEIEE BNB 0 I fl I I (t)� � ryIe tetr _J irc mm I I s MAW UW- AT PIP EAM +eew AC DC �1I ■ �f . . . . . . . . . . . . . OMER: CUST CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. kN)° M2-ZJUUM MOUNTING SYSTEM: ZS Comp V4 w Flashing —Insert MODULES: (26) SolarCity#SC315B2 INVERTER: SOLAREDGE # SE760OH—USOOOSNU2 o•t p I If,,, 8.19 245 BIG SPRING TERRACE SANFORD, FL 32771 KW PV ARRAY PAGE NAME: THREE LINE DIAGRAM DESIGN: squ SHEET: REV: DATE 5 3/29/2018 -SLn ";^SolarQty ®pSolar Next -Level PV Mounting Technology "i""SolarCity ®pSolar Next -Level PV Mounting Technology .ZS Comp for composition shingle roofs Components Mounting Block Array Skirt Part No. 850-1633 Part No. 850-1608 or 500-0113 Listed to UL 2703 Listed to UL 2703 Interlock Part No. 850-1388 or 850-1613 Listed to UL 2703 a � Flashing Insert Grip Ground Zep V2 Part No. 850-1628 Part No. 850-1606 or 850-1421 Part No. 850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 �OMPq T� Description PV mounting solution for composition shingle roofs e� Works with all Zep Compatible Modules COMP"I' Auto bonding UL-listed hardware creates structural and electrical bond ZS Comp has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Captured Washer Lag End Cap U� LISTED Part No. 850-1631-001 Part No. Specifications 850-1631-002 (L) 850-1586 or 850-1460 850-1631-003 (R) 850-1588 or 850-1467 Designed for pitched roofs 850-1631-004 Installs in portrait and landscape orientations ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 Wind tunnel report to ASCE 7-05 and 7-10 standards ZS Comp grounding products are UL listed to UL 2703 and UL 467 ZS Comp bonding products are UL listed to UL 2703 Engineered for spans up to 72" and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices Leveling Foot Part No. 850-1397 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800.1839-001 Rev D Date last exported: April 29, 2016 11:22 AM DC Wire Clip Part No. 850-1509 Listed to UL 1565 This document does not create any express warranty by Zap Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps. zspats.com. Document # 800-1839-001 Rev D Date last exported: April 29, 2016 11:22 AM solar SolarEdge Power Optimizer - Zep Compatible TM Module Add -On For North America P300-ZEP, P400-ZEP Compatible with Zep Groove framed modules - Certified Zep Compatible" bracket - Attaches to module frame without screws - reduces on -roof labor and mounting costs - Power optimizer equipment grounded through the bracket - Up to 25% more energy - Superior efficiency (99.5%) - Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading - Flexible system design for maximum space utilization - Next generation maintenance with module -level monitoring - Module -level voltage shutdown for installer and firefighter safety USA -CANADA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -UK -ISRAEL -TURKEY -HUNGARY -BELGIUM -ROMANIA -BULGARIA www.solaredge.us solar=@@SolarEdge Power Optimizer - Zep CompatibleTM Module Add -On For North America P400-ZEP Rated Input DC power'tl ............... Absolute Maximum Input Voltage (Voc at lowest temperature) ....._...._........................... MPPT Operating Range Maximum Short Circuit Current (Isc) _ _ ._ . __.._........................ Maximum DC Input Current ........... I ................... Maximum Efficiency Weighted Efficiency _.............................. P300-ZEP (for 60cell PV modules) I P400-ZEP (for72 & 96-cell modules) 300 400 W 48 80 Vdc ................................................................................ 48 8 - ................................. 8-80 .......................... .................. ...... I....... Vdc .... 30 ...............12.5........................................12.63........................Adc..... 10.1 Adc ............................................... ............................................................. 99.5 .............................................................................................. % .............. 98.8 ............ ................... ................I......................._._................ I % ............. OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc .._ ...............................................................................I.......I.......I.............. Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC Safety RoHS INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage ................................................................. ..... Dimensions including mounting bracket (WXLxH) I Dimensions excluding mounting bracket (WXLxH) 1 ._.......... I ............. Weight (including cables and mounting bracket) ................................................. Input Connector ...... ....._ ... - .................... Output Connector Output Wire Length .................. ............ ....... I ......... ..... Operating Temperature Range ..Protection Rating ............................................... ..............Rati...............................I................. Relative Humidity .............................................................. m Rated STC power of the module. Module of up to+5% power tolerance allowed. FCC Part15 Gass B, IEC63000-6-2, IEC61000-6-3 ......... ........... IEC62109-1(class II safety), UL1741 Yes 1000 Vdc _............. ...._............_ .__..._.._....._......._..I. .... t8x196x27.5/5x7.71x1.08 128 x 196 x 35 / 5 x 7.71 x 1.37 mm/in ...................................................................................................... tgx152x27.5/5x5.97x1.08 128x152x35/ mm/in Sx5.97x1.37 720 / 1.6 840 / 1.9....................kg / lb ................................................. MC4 Compatible --------........._................._.......--................ . Double Insulated; MC4 Compatible _ 31.9- ............................. 0.95/3.0 ...... ..2/3.9 m/ft -40 - +85 / -40 - +185 'C / 'F .....................................................................................1....1....... IP68 / NEMA 6P ........................................_........ ....-........................ .I............ 0 - 100 % PV SYSTEM DESIGN USING A SINGLE PHASE SINGLE PHASE THREE PHASE SOLAREDGE INVERTERIzi HD -WAVE 208V Minimum String Length (Power Optimizers) 8 10 _.__ ......._........................................... __........................ Maximum String Length (Power Optimizers) 25 25 __. - ......................................... Maximum Power per String5700 (6000 with 5250 6000 SE7600H-US) Parallel Strings of Different Lengths or Yes Orientations ......_.._................................................................................................................ (2) for detailed string suing Information refer to: httpJ/www.wiaredge.mm/s¢es/defaulVflles/ming_slzlr4Lm.pdf. THREE PHASE 480V 1..8 ............................ . 50 12750 W solar =@@ SolarEdge Single Phasi for North America SE3000H-US / SE380OH-US / SE5000H SE760OH-US • �i J Optimized installation with HD -Wave technology Record -breaking efficiency Integrated arc fault protection for NEC 2011 690.11 and integrated rapid shutdown for NEC 2014 690.12 Extremely smal High reliability without any electrolytic capacitors 11111110111I D Built-in module -level monitoring wave Outdoor and indoor installation wave — Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.S% accuracy) Optional: Self -Sustaining Power - produce up to 1.5kW directly from PV during grid failure USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTHAFRICA-BULGARIA www.solaredge.us solar ' • • . Single Phase Inverters for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US - - SE3000H-US I SE39WH-US -- I SESOOOH-US j - - SE6000H-US I -- SE760OH-US - OUTPUT Rated AC Power Output 3000 ....... 3800 .................... 5000 6000 7600 VA Max. AC Power Output ............................................. 3000 3800 .................... 5000 .................... .................... 6000 7600 .................... VA ............. AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) ..................................................... - ................... .................... ✓ .................... .................... - - .................... Vac ............. AC Output Voltage Min: Nom.-Max. (211 - 240 - 264) ✓ .... ..✓ .................. ✓ ........ ..... ✓ .. ✓ .......... . Vac AC Frequency (Nominal) .................... 59.3 - 60 - 60.5 Ili .................... .................... .................... Hz ........ ...... ... ..... ........ .......I.. .. ............................. Maximum Continuous Output Current 208V ..............P...................,............................. .2-1 .................. 24 .................... ..........:......... ..........:........ A ............. Maximum Continuous Output Current ............. 12.5 16 21 25 32 A ........ ................. .............. GFDI Threshold 1 A ............. .......... ....................... ................. Utility Monitoring, Islanding Protection, ............................................... Yes.................................................. Maximum DC Power ................................................................................ 4650 5900 7750 9300 11800 .................... .................... .................... .................... W ............. Transformer -less, Ungrounded Yes Maximum Input Voltage Vdc Nominal DC InP ut Voltag a 380 400 Vdc Maximum Input Current 208V ...............I............................. - 15.5 .. ..........:......... .................... ................... ... Maximum Input Current 240V 8.5 10.5 13.5 16.5 20 ....... ... ....... Adc ............. .................................I.......I. Max. Input Short Circuit Current ......................................................................................I........................I 45 .................................................. Adc Reverse-Polari Protection Yes ............. ................................................................................................................................................. Ground -Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency ............_............. 99 99.2 .....I...... % ........... CEC Weighted Efficiency. ...... ...................... ........... 99 % Nighttime Power Consumption < 2.5 W SELF-SUSTAINING POWER OUTLET (OPTIONAL) Nominal Output Voltage 120 V Maximum Output Power .............................................................................................................................................................. 1500 W ............. External Outlet with GFDI Yes ADDITIONAL FEATURES Supported Communication Interfaces R5485, Ethernet, ZigBee (optional), Cellular (optional) ................. Internal RGM support ....... ............................... ANSI C12.20 class 0.5 compliant ........................ Rapid Shutdown*- 2014 690.12 Automatic Rapid Shutdown STANDARD COMPLIANCE Safety UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 ....................................... ............ ............. Grid Connection Standards IEEE1547, Rule 21, Rule14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 0.75-1" Conduit / 14-6 AWG _............................................. _.......... ...... _........................................ ............. DC Input Conduit Size / # of Strings / AWG Range 0.75-1" Conduit /1-3 strings / 14-6 AWG ...... ............................... ............. Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 z 370 x 174 in / mm Weight with Safety Switch............................................................. ...............25... 11:5.................. .... ................. .. I.......... No < 25 dBA ........ise ............................................................................................................................................................ ............. Cooling Natural Convection ........_....................................... ............. 3� Operating Temperature Range 13 to +140 / -25 to +601 ( 40'F / 40'C option) 'F / 'C ............................................................. ............................... Protection Rating NEMA 3R (Inverter with Safety Switch) ........................................................................ ................................................................... in For other regional settings please contact SolarEdge support Depends on PV availability 131 Power de -rating from 50'C SC-B2 SERIES MODULE MORE POWER, FEWER MODULES With a sunlight to electricity conversion efficiency of over 18.8%, the module ranks amongst the highest in the industry. That means our modules can harvest more energy from the sun, which means it takes fewer of our modules to power your home. Plus, they generate more power output during the hottest times of the day, even in warmer climates. SC315132 AND SC31062 BLACK MODULE Zep Compatible 96-Cell Black -on -Black PV Module For use in residential and commercial PV installations MORE POWER PER MODULE Our 315W module generates 16% more power than a standard 270 W module. MORE ENERGY EVERY YEAR More yearly energy (kWh) compared to other modules as they perform better in the heat. MORE LAYERS, MORE POWER Manufactured by Panasonic for SolarCity, the module uses Heterojunction cell technology, which adds a layer of thin film silicon on top of high efficiency crystalline silicon. OUTSTANDING DURABILITY With more than 20 additional tests performed beyond what is currently mandated, these modules far exceed industry standards. LEADING WARRANTY Our modules rank among the best in warranty coverage, with workmanship that extends to 15 years. LIMITED WARRANTY Power Output 10years (90%ofPM,) 25 years (80% of PM.) Workmanship 15 years MATERIALS Cell Material 5 inch photovoltaic cells Glass Material AR coated tempered glass Frame Materials Black anodized aluminum CAUTION Please read the installation manual carefully before using the product. Modules are manufactured by Panasonic to the specification of SolarCity. Modules are only warranted by Panasonic if the modules are included in a PV system sold by SolarCity or Tesla. SolarCity and Tesla make no warranties related to the modules, which are sold as -is. SolarCity will handle any warranty claims on behalf of any purchaser. SOLARCITY 1146037-00-A 1 MODULE SPECIFICATIONS ELECTRICAL CHARACTERISTICS Model ------------ SC315B2 SC310B2 Max Power (VV) 315 ............. - ----_ 310 .. ............ Max Power Voltage, VMp (V) 58.4 58.1 Max Power Current, IMP (A) 5.40 5.34 Open Circuit Voltage, V. M 70.2 69.9 Short Circuit Current, I. (A) 5.83 5.78 System Voltage (V) 600 600 Max Series Fuse Rating (A) 15 15 Solar Module Efficiency (%) 18.8 - - ... 18.5 .. ---- ----- Power Tolerance (%) +5 / -0 +5 / -0 AT NOCT (NORMAL OPERATING CONDITIONS) Model SC315B2 SC31OB2 Max Power (W) 234.6 230.7 Max Power Voltage, VMP M 53.6 53.3 Max Power Current, IMp (A) 4.37 4.33 Open Circuit Voltage, V. (V) 65.7 65.4 Short Circuit Current, Isc (A) 4.70 4.66 MECHANICAL DATA Weight 19.5kg (42.99lbs) Dimensions 1590 mm (62.60") / 1053 mm (41.46") / 40 mm (1.57") Connector MC4 Frame Color Black S a Wind and Snow Load 2400 Pa (50lbs/ft') Fire Type UL 1703 Type 2 Section A -A' Section B-B' Section C-C' SOLARCITY TEMPERATURE CORRECTION NOCT ('C) 49 P, (%/°C) -0.29 -__ - --------------- VW (%/"C) -0.25 Iac (%/°C) 0.03 Electrical characteristics are within-5/+10% of the indicated values of lu., V_ and PM. under standard test conditions (irradiance of 100 mW/cm, AM 1.5 spectrum, and a cell temperature of 25 degrees Celsius or 77 degrees Fahrenheit). AT LOW IRRADIANCE (20%) Model SC315B2 SC310B2 Max Power (W) 59.7 58.6 Max Power Voltage, VMe M 55.7 55.2 Max Power Current, IMP (A) 1.07 1.06 Open Circuit Voltage, V. (V) 65A 65.0 Short Circuit Current, 1. (A) 1.17 1.16 1146037-00-A a, n sr, _T Unit: mm (in) 2