HomeMy WebLinkAbout524 San Lanta CtCITY OF T r7a ;re Building & Fire Prevention Division FOt MAY 1 � 201 PERMIT APPLICATION FIRE DEPARTMENT- — 1 3 BY:. -- - - - Application No: 1Q) O� Documented Construction Value: $ 1415.00 Job Address: 524 San Lanta Circle Historic District: Yes❑NoFv—1 Parcel YD: 31-19-31-505-0000-1240 Residential Commercial❑ Type of Work: New❑ Addition❑ Alteration❑✓ Repair❑ Demo❑ Change of Use❑ Move❑ Description of Work: Remove and replace exterior main panel. Plan Review Contact Person: Jim DePoy Phone:407-322-1562 Fax:407-330-1764 Name Christopher Butler Title: Elec Contractor Email:jdepoysec@gmail.com Property Owner Information Street: 524 San Lanta Circle City, State zip: Sanford FI. 32771 Name Sanford Electric Co II Street: 107 Commerce Way City, State zip: Sanford FI. 32771 Name: N/A Street: City, St, Zip: Bonding Company: N/A Address: Phone: 407-529-4919 Resident of property? : no Contractor Information Phone: 407-322-1562 Fax: 407-330-1764 State License No.: Ec13001943 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: N/A Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6' Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713, The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID gnature of Contractor/Agent Date A/ P nt ontractor/Agent'sb4me Signature of No ary-State of Florida tiuumm NOTARY PUBLIC STATE OF FLORIDA 6at,,LW Comm# FF911626 E-Vres 9/8/2019 Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas ❑ Roof ❑ Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Flood Zone: # of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes ❑ No WASTE WATER: BUILDING: Revised: January 1, 2018 Permit Application 5/9/2018 SCPA Parcel View: 31-19-31-505-0000-1240 Year Built # Description Fixtures Bed Bath Base Area Total SF Living SF Ext Wall Adj Value Repl Value Appendages Actual/Effective ---- - - - - ------ ---- _ __---- 1 [SINGLE 1973 6 3 : 2 0 ' 1,026 1,749 € 1,531 BRICK+WOOD $80 905E $106,454 Description Area i http://parceldetail.scpafl.org/ParcelDetaillnfo.aspx?PID=31193150500001240 1/2 SANFORD ELECTRIC COMPANY II, INC. Electrical Contractors Proposal 107 Commerce Way COMMERCIAL ❑ SPECIFICATIONS NO. 18-OSSR Unford, FI. 32773 RESIDENTAL ® AND ESTIMATE jdepoysec@gmail.com SERVICE ❑ (407) 322-1562 — FAX (407) 330-1764 Contractor # EC13001943 Page No. 1 of 1 Page Proposal Submitted to Phone Date Christopher Butler 407-529-4919 4-15-18 Street Job Name 524 San Lanta Circle Exterior Panel Replacement City, State and Zip Code Job Location Sanford Fl. 32771 Same ATTENTION Job Phone Christopher crsbtlr@yahoo.com We hereby propose to furnish materials and labor necessary for the completion of: Provide removal and replacement of existing exterior panel. 1)Mark and label existing circuitry, disconnect circuitry and remove cables and conduits. Remove feed from meter and remove panel. 2)Provide new ITE Siemens W2040ML1200 panel and ground bar. Provide new 150 amp main breaker. 3)Provide new ITE breakers as follows; (1) 2 pole 20, (1) 2 pole 50, (4) 2 pole 30's, (4) 20/20 tandem's, (2) 15115 tandem breakers. 4)Install new 2/0 Al. XHHW conductors from meter base to main breaker. Provide new wire as needed to extend existing circuitry to new breaker locations. 5)Provide new 1 %2" myers hub for top of panel and 1 1/2" PVC chase to sleeve existing romex cables. 6)Electrical Permit. WE PROPOSE hereby to furnish material and labor — complete in accordance with above specifications, for the sum of One Thousand Four Hundred Fifteen Dollars $ 1415 00 Payment to be made as follows: Due Upon Completion All material is guaranteed to be as specified. All work to be completed in a substantial workmanlike Authorized manner according to specifications submitted, per standard practice. Any alteration or deviation from Signature IT/,or 9000 above specifications involving extra costs will be executed only upon written orders and will become an extra charge over and above the estimate. All agreements contingent upon strikes, accidents or delays Note: This proposal may be withdrawn beyond our control. Owner to carry fire, tornado, Builders Risk, 8, other necessary insurance. by us if not accepted with 30* days. Our workers are covered by Workmen's' Compensation Insurance. ACCEPTANCE OF PROPOSAL The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. Signature Date of Acceptance: Signature