HomeMy WebLinkAbout900 S Elm Ave (2)s ' .2 2018
CITY OF
_ _Building & Fire Prevention Division
FPERMIT APPLICATION
S��FIRE DEPARTMENT �% — 2 �o'
Application No:
Documented Construction Value: $ i 0 o
Job Address: Do J "�� y�� ��52_�we Historic District: Yes[ANo❑
Parcel ID• Residential Commercial❑
Type of Work: New❑ Addition❑ Alteration ❑ Repair S�emo ❑ Change of Use❑ Move ❑
Description of Work: K �2 :�:M STS
Plan Review Contact Person: Title:
Phone: Fax: Email:
LcProperty Owner Information q
Name t �2. f�- � Phone: �0-7 ` / —�/ 7
Street: 1 Resident of property? :
City, State Zip:
Name
Street:
City, State Zip:
Name:
Street:
City, St, Zip:
Bonding Company: _
Address:
Contractor Information
Phone:
Fax:
State License No.:
Architect/Engineer Information
Phone:
Fax:
E-mail:
Mortgage Lender:
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6" Edition (2017) Florida Building Code
Revised: January 1, 2018 Permit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
Signature of Owner/Agent Date
Print Owner/Agent's Name
of
Notary State of Florida
. IL Ha
r. INNancy Naufe
My Commission GG 002231
o, adl Expires 061612020
y/S//00-1,
Owner/Agent is V Personally Known to Me or
Produced ID Type of ID
Signature of Contractor/Agent Date
Print Contractor/Agent's Name
Signature of Notary -State of Florida Date
Contractor/Agent is Personally Known to Me or
Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing[] Gas[] Roof ❑
Construction Type:
Total Sq Ft of Bldg:
Occupancy Use:
Min. Occupancy Load:
New Construction: Electric - # of Amps
Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads
APPROVALS: ZONING:�,Io TILITIES:
ENGINEERING:
COMMENTS:
FIRE:
Flood Zone:
# of Stories:
Plumbing - # of Fixtures.
Fire Alarm Permit: Yes ❑ No ❑
WASTE WATER:
BUILDING: 4;c- 5-2" 19
Revised: January 1, 2018 Permit Application
RECORD COPY
Structural Observation Report
Single -Family Residence in Sanford
900 S. Elm Avenue
Sanford, FL 32771
April 24, 2018
6J\� WG
SQNFo
Prepared for: _
Mike & Erika Crenshaw, Owners °FPAR�
Prepared by:
Devlen Engineering, Inc.
4021 Church Street
Sanford, FL 32771
www.devleneng.com
(D.E. Project 2018-194)
L EXECUTIVE. SUMMARY
Devlen Engineering was retained to observe evaluate, and make recommendations
regarding the condition of five new wood porch columns supporting the roof of the rear
porch of the subject residence. It is our, understanding. that this residence is currently up
for sale and that the building department issueda violation for work without a permit,
requiring inspection from a structural engineering firm.
Through a site visit and conversations with the homeowner, it is our understanding that
the existing wood posts at the rear porch were significantly deteriorated and subsequently
replaced with new pressure treated 6x6 wood posts.
In Devlen Engineering's professional opinion, some additional fasteners should be
installed at the top of column location. to ensure that uplift forces from the existing roof'
structure can be transmitted
fro m the perimeter beam to. posts below,
LI. BACKGROUND AND INSPECTION FINDINGS
Devlen Engineering was retained by the homeowner to investigate and document porch
columns that were replaced due to deterioration for the subject home located in Sanford,
FL. Mr. Brett Bartz, P.E. met Mrs. Erika Crenshaw at the residence and discussed: the
history behind the column replacements. He also spoke to Mr. Mike Crenshaw (via phone
call), who installed the replacement. columns. Please note that repair recommendations
and details are beyond the scope of this report and are not included.
Mr. Brett J. Bartz, PE visited the subject location, making the following observations:
Date- April 24, 2018
Time: 1.0.00 am 11'-.00' am
Weather: Typically clear, 75 degrees F
Access Methods: Walking, interior' and 'exterior of residence.
The residence is a one-story, single-family structure that faces east (herein. east for
reference in this report). Data from the Seminole County tax appraiser indicates the home.
was built originally in 1920 and consists of 1912 square feet gross area and 1408 square
feet living area under roof. The house includes an open front porch and open rear porch
on the east and west faces of the houses. and is situated on a lot with a mild slope which
slopes away from the house. The. residential structure is observed to have wood siding
over wood frame construction with a shingle -covered roof (roof and wall. elements are
outside the scope of this report). See Photo #1.
Porch Post (column) Inspection:
The subject- of this inspection are the five (5) wood columns that support the roof of the
rear covered porch (Photo #1). These columns measured 5 1/Z' x 5 1/2" square and
were approximately 96 tall. No visible lumber grading marks were, observed, but the
exposed portions of the the columns that were not painted were consistent with pressure -
treated southern yellow pine. The base of these columns bore on built-up pre -cast
concrete pedestals and were thru-bolted to deck framing below with at least one (1) 1,/2"
2
s
diameter carriage bolt (Photo #2).'The top end of the column was notched approximately
3"' wide by 6" deep to receive the perimeter beam of the porch The columns were
attached to the roof perimeter beam with (4) 3" long deck screws at each location (Photo
#3).
Conclusions and Recommendations
This: report is limited to observations and inspection of the (5) 6x6 rear porch wood
columns.
The. 6x6 pressure treated wood columns have adequate capacity to support the design
loads from the covered porch roofabove. The following design loads were used for this
determination:
Roof bead Load` ....... _ ..15psf
Roof Live Load ... _ ........ 20 psf
Wind Design' Criteria:
Wind Design Speed-......... 139mph (ult.)
- - Exposure = -B - - ---- - - - -- -- -- - - -
Risk Category . -Il
Uplift (nominal) ..............-1.8.9psf
The single 1/2" carriage bolt is sufficient at the base connection to carry the uplift loads
to the deck framing below. At the top of these columns, deck. screws were utilized for the
connection. beck screws are not recommended for structural connections since they are
not a ductile fastener and may undergo brittle failure without any warning like a ductile
fastener would..
A single,1/2diameter carriage bolt with hex nut and flat washer (all hot -dip galvanized')
shall be installed at the top of each column in addition to the deck screws. See attached'
sketch SK-01 for proper placement of these bolts.
3
III. PHOTOGRAPHS
PHOTO 1
PHOTO 2
Bottom of Column Bearing Condition & Connection Detail.
PHOTO 3
Top of column connection to edge beam.
IV. STATEMENT
Devlen Engineering stands behind the findings of this report but reserves the right to add
or to modify this report should new information be presented or discovered at a later date.
This report was made for the exclusive use of Mr & Mrs. Mike Crenshaw, and is not to be
used as a repair manual or guide by other engineers or contractors.
Respectfully submitted,
04-24- l 8
Brett J. Bartz P.E.
FL Reg. No. 75359
Devlen Engineering, Inc., COA No. 9459
EXIST RAFTER
(B'El'OND)
EXIST. ROOF / A \-1/2"` D1A. CARRIAC-,E
BEAT" i BOLT
%X& R.T.
_WOOD COL. 1, EXIST. ROOF BEA
(SYF #2)- SECTION A -A
1/2" DIA. CAS
BOLT U
WASHER
F. ROOF
1.
F'.T.
wvvv COL..
,`gy;�remee�fftkf�. (Sl P 02)
Or
b
F ,- Qj: SCALE: 1 1/2" = 1'-0"
.,�
O�• r r a p �"
BRETT`J. BARTZ
FL. REG.-NO. 75359
O
Pmj. No..: 18-194 DEVLEN ENGINEERING, Inc..: DATE: 04/24/201
STRUCTURAL ENGINEERING 4021 CHURCH ST.
DR'AMIN] ME G.O.A. 9459 SANFORD, FL 32771
PHONE: (407) 324-5300
FAX`. (407)324-5999
CHECK: B J B EN AIL: RON@:DEVLENENG.COM
WEB: WWW.DEVLENENG:COM
900 S. ELM AVENUE SANFORD FL 32771 SK_O 1
BP200I01
CITY OF SANFORD 5/02/18
Application Inquiry 13:35:54
Application number . . .
. . 18 00002101
Application status, date
. . CLOSED 5/02/18
Property . . . . . . . .
. . 900 ELM AVE
Parcel Number. . . . . .
. . 25.19.30.5AG-1107-0010
Old CID . . . . . . . . .
. .
Subdivision . . . . . .
. . TWN OF SANFORD (TRAFFORDS MAP)
Zoning . . . . . . . . .
. . : SR1 SINGLE FAMILY
Application type . . . .
. . GNRP GENERAL REPAIRS RESIDENTIAL
Application date . . . .
. . 5/02/18
Tenant number, name . .
. .
Master plan number, rev'wd by: AB
Estimated valuation . .
. . 450
Total square footage . .
. . 0
Public building . . . .
. . NO
Work description, qty .
. .
Pin number . . . . . . .
. . 804801
Application desc . . . .
. . REPAIR ROTTEN WOOD
Press Enter to continue.
F3=Exit FS=Land inq F7=Appl names F8=Tracking inq F9=Bond inquiry F10=Fees
F11=Receipts F12=Cancel
F13=Val calcs F14=Misc info F24=More keys