HomeMy WebLinkAbout3773 Crawley Down Lp 18-918; NEW SFHCOUNTY OF SEMINOLE ' Q}
IMPACT FEE STATEMENT Q
STATEMENT NUMBER: 18100001 DATE: February 20, 2018BUILDINGAPPLICATION #: 18-10000141
BUILDING PERMIT NUMBER: 18-10000141
UNIT ADDRESS: CRAWLEY DOWN LOOP 3773 17-20-31-5VC-0000-1250
TRAFFIC ZONE:022 JURISDICTION:
SEC: TWP: RNG: SUF: PARCEL:
SUBDIVISION: TRACT:
PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT:
OWNER NAME:
ADDRESS:
APPLICANT NAME: NVR INC DBA RYAN'HOMES
ADDRESS: 4307 VINELAND ROAD SUITE H-20 ORLANDO FL 32811
LAND USE: SINGLE FAMILY RESIDENCE
TYPE USE:
WORK DESCRIPTION: CITY-SANFORD
SPECIAL NOTES: 3773 CRAWLEY DOWN LOOP / KENSINGTON
RESERVE / SFR
FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUETYPEDISTSCHEDRATEUNITSTYPE
ROADS-ARTERIALS CO -WIDE ORD
Single Family Housing 705.00 1.000 dwl unit 705.00
ROADS -COLLECTORS N/A
Single Family Housing .00 1.000 dwl unit .00FIRERESCUEN/A
LIBRARY CO -WIDE ORD
00
Single Family Housing 54.00 1.000 dwl unit 54.00SCHOOLSCO -WIDE ORD
Single Family Housing 5,000.00 1.000 dwl unit 5,000.00PARKSN/A
LAW ENFORCE N/A
00
DRAINAGE N/A .
00
00
AMOUNT DUE 5,759.00
PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE
SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL
ISSUANCE OF A BUILDING PERMIT.
PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER
TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES
MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDARDAYSOFTHEDATEABOVE, BUT NO LATER THAN
CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW
MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE.
COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED,
FROM THE BUSINESS OFFICE• 1101 EAST FIRST STREET,
SANFORD FL, 32771; 407-665-7356.
PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD
BUILDING DEPARTMENT
1101 EAST FIRST STREET
SANFORD, FL 32771
PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE
THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT.
THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT
ISSUED WITHIN 60 CALENDAR DAYS FROM THE DATE ABOVE
REQUIRED INSPECTION SEQUENCE
RYAN HOMES SFR-DETACHED
Permit #
BUILDING PERMIT
Min Max Inspection Description
10 Form board / Foundation Survey
10 Slab / Mono Slab Prepour
20 Lintel / Tie Beam / Fill / Down Cell
30 Sheathing — Walls
30 Sheathing — Roof
30 50 Final Window
40 Roof Dry In
50 Frame
60 Insulation Rough In
70 Drywall / Sheetrock
40 70 Lath Inspection
50 1000 Final Roof
50 1000 Final Stucco / Siding
80 1000 Insulation Final
1000 Final Single Family Residence
Addrecc:
Min Max Inspection Description
10 Electric Underground
10 Footer / Slab Steel Bond
20 30 Temporary Underground Power (TUG)
30 Electric Rough
1000 Electric Final
N Pu[
s.5yefi53f"'^"•M h?
tB1,.', .: "*.4.. ,,..m,ukC,3r".yi, t14s9 +
Inspection DescriptionMinMax
10 Plumbing Underground
20 Plumbing Tubset
10 1000 Plumbing Sewer
1000 Plumbing Final
r^r' i€",r%' KX -:
ME.CHANICALPERMIT7..._.... ... ...._, _I'i . ..,... ,
K... ....a.-....
ram?. z;. •' x - `v'a.
wr " . k +fi+.... R.. ..a..s,.....c>i .. v,,._.,....
Min Max Inspection Description
10 Mechanical Rough
1000 Mechanical Final
REVISED: June 2014
1 iilll iilii illll iliii illil I ili illl liil
THIS INSTRUMENT PREPARED BY:
GRANTtlral_C?Y, SEh1Il°10LE COUNTYName: NVR Inc. dba Ryan Homes (
C:LEF;, OF CIRCUIT G0 1F:T tz COMPTROLLERAddress: 4307 Vineland Rd, Suite H-20 CLERKRK i F's RCUI ( CO
s ) Orlando FL 32811 C:LERK's v 2018034516
RECORDED 03;29/201u 12°33e --' PH
NOTICE OF COMMENCEMENT RECORDED
FEES
lid torca ICI
REGORDE!) I''t' hdevut'r_
Permit Number: 18-0686
Parcel ID Number: 17-20-31-5VC-0000-0610
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the
following information is provided in this Notice of Commencement.
1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available)
Lot # 61 of Kensington Reserve 3677 Crawley Down Loop
2. GENERAL DESCRIPTION OF IMPROVEMENT:
Construction of Single Family Home Residential
3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT:
Name and address: NVR Inc. dba Ryan Homes- 4307 Vineland Rd, Suite H-20 Orlando FL 32811
Interest in property:
Fee Simple Title Holder (if other than owner listed above) Name: NA
4. CONTRACTOR: Name: NVR, Inc dba Ryan Homes Phone Number: 407-692-9820
Address: 4307 Vineland Rd, Suite H-20 Orlando FL 32811
V 5. SURETY (If applicable, a copy of the payment bond is attached): Name: NA
Address: Amount of Bond:
6. LENDER:
Address:
Phone Number:
7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section
713.13(1)(a)7., Florida Statutes.
Name:_ Dayna Whitson Phone Number: 407-
C.RTIFIE
0 OPCIRCU T COURT
OY
Aririrvss. 4307 Vineland Rd Suite H-20. Orlando FL 32811 AND COMPTR, 016LER 3
8. In addition, Owner designates of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number: B .
9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different da 9
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE
CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE
JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Dayna Whitson Assistant Secretary
Signature of 16jner or Lessee, or Owners or Lessee's (Print Name and Provide Signatory's Title/Office)
Authodz Officer/Director/Partner/Manager)
State of Florida County of Orange
The foregoing instrument was acknowledged before me this —2— day of l v` 20 18
by Dayna Whitson Who is personally known to l(OR
Name of person making statement
who has produced identification type of identification produced:
i°, Y"u>4•, TRACY LEIGH i\i1CDONALl::
N1Y"CONiNIISSION # FF9250'
c EXPIRES October 06. 20"IS Of iVn•
1407) 99t3 0 53 f luridallo aryS:;rvlce cen"
REQUEST FOR TUG & PREPOWER AGREEMENT
Dater
Project Name:
ALL RESIDENTIAL PROPERTIES
Altamonte Springs, Casselberry, Longwood, Oviedo, Sanford,
Seminole County, Winter Springs
Project Address: , 5 O o .
Building Permit #: I Y —C) ( Electrical Permit #
Kensington Reserve
In consideration for authorizing the appropriate utility company to energize the facility, we agree with and
understand the following:
1. This Tug/Pre-power application is valid only for one -and two-family dwellings.
2. The facility will not be occupied until a certificate of occupancy has been issued.
3. If the jurisdiction hereafter finds that the facility has been occupied before a certificate of occupancy has
been issued, the jurisdiction will have the unilateral right to direct the utility to terminate electrical service
without notice. Furthermore, we understand and agree that should the jurisdiction exercise such right, the
jurisdiction will not be responsible for any damages or costs which may result from the exercise of such
right. Also, in the event any third party claims damages from the exercise of such right, we agree to jointly
and individually indemnify and hold harmless the jurisdiction from all such damages and costs, including
attorney's fees.
4. Prior to pre -power, the building or structure shall be weather tight and secure. The electrical wiring in the
area designated for pre -power shall be complete and in safe order. All electrical services associated with the
area will be 100% complete unless specifically approved by the electrical inspector.
5. Interior electrical rooms shall be lockable, if electrical panels are in an area that cannot be locked by doors,
the panels shall be equipped with a locking mechanism (approved by the AHJ). The licensed electrical
contractor or his licensed representative shall hold the keys(s) for such access to electrical panels to prevent
energizing circuits other than those that are safe.
6. This TUG/Pre-power approval is valid for a maximum of 180 days from date of approval.
7. If provided, the fire sprinkler system must be operational with water on the system prior to pre -power.
8. TUG approval is for service and outside GFCI outlets only.
9. Check with the local jurisdiction for fees associated with tugs.
Robert Lattanzi - Ryan Homes
Print Name f Owner/Ten
Signature of ner/Tenant
Robert Lattanzi - Ryan Homes
Print Nam ofklen. Co tra
Signature of Gen. Contractor
C BC 1257565
Gen. Contractor License #
Scott L Easterbrook - Palmer Electric
Print Name of El. Contractor
ignature of El. Contractor
EC0003096
El. Contractor License #
JURISDICTION EMPLOYEE NAME:
JURISDICTION:
CALLED INTO: Progress Energy Florida Power and Light on_
Rev. 02/10/15)
REQUIRED INSPECTION SEQUENCE
RYAN HOMES SFR-DETACHED
Permit #
BUILDING PERMIT
Min Max Inspection Description
10 Form board / Foundation Survey
10 Slab / Mono Slab Prepour
20 Lintel / Tie Beam / Fill / Down Cell
30 Sheathing — Walls
30 Sheathing — Roof
30 50 Final Window
40 Roof Dry In
50 Frame
60 Insulation Rough In
70 Drywall / Sheetrock
40 70 Lath Inspection
50 1000 Final Roof
50 1000 Final Stucco / Siding
80 1000 Insulation Final
1000 Final Single Family Residence
Address:
Min Max Inspection Description
10 Electric Underground
10 Footer / Slab Steel Bond
20 30 Temporary Underground Power (TUG)
30 Electric Rough
1000 Electric Final .
rtt=.>.;
xi.
r`, 4+ K y ,
G,
k ."
i q 3 r*arb .i'"'' . ,
Min Max Inspection Description
10 Plumbing Underground
20 Plumbing Tubset
10 1000 Plumbing Sewer
1000 Plumbing Final
ME.CHANICAL*PERMIT s."K.. ` •^ ' *`
Min Max Inspection Description
10 Mechanical Rough
1000 Mechanical Final
REVISED: June 2014
FEB 1e 2018
1
h C
CITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
Application No:
Documented Construction Value: $ 4ReM
Job Address: 3773 Crawley Down Loop
Parcel ID: 17-20-31-5VC-0000-1250
Type of Work: New X Addition Alteration
Description of Work: New Single Family Residence
Historic District: Yes No X
Residential X Commercial
Repair Demo Change of Use Move
Plan Review Contact Person: Tracy McDonald Title: Production Admin
Phone: 407-692-9831 Fax: Email: trmcdona@nvrinc.com
Property Owner Information
Name NVR INC. dba Ryan Homes Phone: 407-692-9831
Street: 4307 Vineland Rd #H20 Resident of property?
City, State Zip: Orlando FL 32811
Contractor Information
Name NVR, Inc, dba Ryan Homes Phone: 407-692-9820
Street: 4307 Vineland Rd # H-20 Fax: 407-692-9821
City, State Zip: Orlando FL 32811 State License No.: CBC1257565
Architect/Engineer Information
Name: AB Design Phone: 407-774-6078
Street: 1441 N Ronald Reagan Blvd Fax:
City, St, Zip: Longwood FL
Bonding Company:
Address:
N/A
E-mail: brian@abdesigngroup.com
Mortgage Lender
Address:
N/A
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51' Edition (2014) Florida Building Code
Revised: June 30, 2015 It b I -
Permit Application
3 0 2-'!"
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
P/' 2/15/2018 j 2/15/2018
Signature P\A"gerrt Date Signature f ntr gent Date
Tracy McDonald Tracy McDonald
Print Owner/Agent's Name Print Contractor/Agent's Name
l ----
2/15/2018 2/15/2018
Signature of Notary -State of Florida Date Signature of Notary -State of Florida Date
o Rv pu",, MEAGAN LYNNE FOWLER
ct
LYNNE FOWLER
ON # GG 063253MYCOMMISSION _
u; o EXPIRES: January 17.2021
ota4YMEAGAN
MY COMMISSION # GG 063253
N EXPIRES; January 17.2021
y'F of F G Bonded Tuna Budget Notary Services
o
STF o K4 Bp sd Thna Budget Notary Sery ces
Owner/Agent is X_ Personally Known to Me or Contractor/Agent is X Personally Known to Me or
Produced ID Type of ID Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building ^ Electrical 9 Mechanical W PlumbingV9 Gas Roof
Construction Type: %f P-2 Occupancy Use: R3 Flood Zone: )G S cc
AiToC U{
Total Sq Ft of Bldg: 2 _ Min. Occupancy Load: 1!5 # of Stories: Z-
New Construction: Electric - # of Amps ZOO Plumbing - # of Fixtures I I
Fire Sprinkler Permit: Yes No 5( # of Heads
APPROVALS: ZONING: UTILITIES:
COMMENTS:
ENGINEERING: 'MSC. 7,4& $ FIRE:
Ok to construct single family home
with setbacks and impervious area
shown on plan. 3(o.'7ot.
Lo,feo UCI-A, C,(Z
Fire Alarm Permit: Yes No Y
WASTE WATER:
BUILDING:V 3 -a- e
Revised: June 30, 2015 Permit Application
Job Address: 3773 Crawley Down Loop
Parcel ID: 17-20-31-5VC-0000-1250
Type of Work: New EA Addition
ut
F 1q1 CITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
Application No:
Documented Construction Value: $ 88,191
Historic District: Yes No
Residential X Commercial
Alteration Repair Demo Change of Use Move
Description of Work: New Single Family Residence
Plan Review Contact Person: Tracy McDonald
Phone: 407-692-9831 Fax:
Title: Production Admin
Email: trmcdona@nvrinc.com
Property Owner Information
Name NVR INC. dba Ryan Homes Phone: 407-692-9831
Street: 4307 Vineland Rd #H20 Resident of property? : _
City, State Zip: Orlando FL 32811
Name NVR, Inc, dba Ryan Homes
Street: 4307 Vineland Rd # H-20
City, State Zip: Orlando FL 32811
Contractor Information
Phone: 407-692-9820
Fax: 407-692-9821
State License No.: CBC1257565
Architect/Engineer Information
Name: AB Design
Street: 1441 N Ronald Reagan Blvd
Phone: 407-774-6078
Fax:
City, St, Zip: Longwood FL E-mail: brian@abdesigngroup.com
Bonding Company:
N/A Mortgage Lender: N/A
Address: Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 511' Edition (2014) Florida Building Code
Revised: June 30, 2015 Permit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there maybe additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
10
2/15/2018 A 2/15/2018
Signature e A nt Date Signature f ntr gent Date
Tracy McDonald
Print Owner/Agent's Name
2/15/2018
Signature of Notary -State of Florida Date
Sky P,. MEAGAN LYNNE FOWLER
MY COMMISSION # GG 063253
EXPIRES: January 17, 2021
o: vv Bonded Tnru Budget Notary Services
Tracy McDonald
PrinnttCContractor/Agent's Name
2/15/2018
Signature of Notary -State of Florida Date
o,.av P ,,MEAGAN LYNNE FOWLER
MY COMMISSION # GG 063253
1P021
NfsjFor AP eBonded Thru Budget Notary 3enlces
Owner/Agent is _x Personally Known to Me or Contractor/Agent is X Personally Known to Me or
Produced ID Type of ID Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building Electrical Mechanical Plumbing Gas Roof
Construction Type:
Total Sq Ft of Bldg:
Occupancy Use:
Min. Occupancy Load:
New Construction: Electric - # of Amps
Fire Sprinkler Permit: Yes No # of Heads
APPROVALS: ZONING:
ENGINEERING:
COMMENTS:
Flood Zone:
of Stories:
Plumbing - # of Fixtures
Fire Alarm Permit: Yes No
UTILITIES: 1 0
FIRE:
WASTE WATER:
BUILDING:
Revised: June 30, 2015 Permit Application
City of Sanford
Planning and Development Services
Engineering — Floodplain Management
Flood Zone Determination Request Form
Name: Vicky Otero Firm: NVR, Inc.
Address: 4307 Vineland Road #H20
City: Orlando State: FL Zip Code: 32811
Phone: 407.692.9820 Fax: 407.692.9821 Email: votero@nvrinc.com
Property Address: 3773 Crawley Down Loop
Property Owner: NVR, Inc. dba Ryan Homes
Parcel identification Number: 17-20-31-5VC-0000-1250
Phone Number: 407.692.9820 Email: votero@nvrinc.com
The reason for the flood plain determination is:
New structure Existing Structure (pre-2007 FIRM adoption)
Expansion/Addition Existing Structure (post 2007 FIRM adoption)
Pre 2007 FIRM adoption = finished floor elevation 12" above BFE
Post 2007 FIRM adoption = finished floor elevation 24" above BFE (Ordinance 4360)
EFCIALOYOn,IJ laaaewcFlood
Zone: X Base Flood Elevation: N/A Datum: N/A FIRM
Panel Number: 120294 0090 F Map Date: Sept. 28, 2007 The
referenced Flood Insurance Rate Map indicates the following: The
parcel is in the: floodplain floodway A
portion of the parcel is in the: floodplain floodway The
parcel is not in the: FE-Ifloodplain floodway The
structure is in the: floodplain floodway The
structure is not in the: floodplain floodway If
the subject property is determined to be flood zone `A', the best available information used to determine
the base flood elevation is: BP#
18-918 Reviewed
by: Michael Cash, CFM Date: February 28, 2018
i Application for Paved Driveway, Sidewalk or
WalkwayIncluding Right -of -Way Use & 9 9 Y
Fti°$ 7- Landscaping i11 Right -of -Way
www.sanfordfl.gov Department of Planning & Development Services
300 North Park Avenue, Sanford, Florida 32771
Phone:407.688.5140 Fax:407.688.5141
This permit authorizes work to be done on the subject property or in the City of Sanford's right-of-way in accordance with the
City's regulations and the attached construction plans approved as part of this permit. The permit is required for driveway or
sidewalk construction over 100 square feet of concrete or other material on the subject parcel and / or any construction of a
driveway, walkway or landscape improvements within the city right-of-way. It does not approve any work within any other c
t
jurisdiction's right-of-way. All requested information below as well as a current survey, site plan or plat clearly identifying the Know where below.
size and location of the existing right—of-way and use shall be provided or application could be delayed. Call before you dig.
1. Project Location/Address: 3773 Crawley Down Loop, Sanford, FL 32773
2. Proposed Activity: X_ Driveway Walkway Other:
3. Schedule of Work: Start Date Completion Date Emergency Repairs
4. Brief Description of work: Construction of New Single Family Home
This application is sub itt by:
Property Owner:
Signature:
Address: 4307 Vin nl
Phone: (407) 692-9831
H-20 Orlando, FL 32811
Fax:
Print Name: Tracy McDonald
Email: trmcdona@nvrinc.com Date: 02/15/2018
Maintenance Responsibilities/Indemnification
The Requestor, and his successors and assigns, shall be responsible for perpetual maintenance of the improvement installed under this Agreement. This
shall include maintenance of the improvement and unpaved portion of right-of-way adjacent thereto. Requestor may, with written City authorization,
remove said installation/improvement fully restoring the right-of-way to its previous condition. In the event that any future construction of roadways,
utilities, stormwater facilities, or any general maintenance activities by the City becomes in conflict with the above permitted activity, the permittee shall
remove, relocate and/or repair as necessary at no cost to the City of Sanford insofar as such facilities are in the public right-of-way. If the Requestor does
not continuously maintain the improvement and area in accordance with previously stated criteria, or completely restore the right-of-way to its previous
condition, the City shall, after appropriate notice, restore the area to its previous condition at the Requestor's expense and, if necessary, file a lien on the
Requestor's property to recover costs of restoration.
To the fullest extent permitted by law, Requestor agrees to defend, indemnify, and hold harmless the City, its councilpersons, agents, servants, or employ-
ees (appointed, elected, or hired) from and against any and all liabilities, claims, penalties, demands, suits, judgments, losses, expenses, damages (direct,
indirect or consequential), or injury of any nature whatsoever to person or property, and the costs and expenses incident thereto .(including costs of
defense, settlement, and reasonable attorney's fees up to and including an appeal), resulting in any fashion from or arising directly or indirectly out of or
connected with the use of the City's right-of-way.
I have read and upde-rstand the above statement and by signing this application I agree to its terms.
Signature:
Pre -pour Inspection by:
Application No: _
Reviewed:
Public Works
Utilities
Approved:
Engineering
Site Inspected by:
Special Permit Conditions:
Date: 02/15/2018
This permit shall be posted on the site during construction.
Please call 407.688.6080 24 hours in advance to schedule a pre -pour inspection.
Date:
Official Use Only
Fee: Date:
Date:
Date:
Date:
Date:
November 2015 ROW Use Driveway.pdf
2/15/2018 SCPA Parcel View: 17-20-31-5VC-0000-1250
t1avl0 OtYtlQn, CiA
see v+oi.c cauxry a.r n
Property Record Card
Parcel: 17-20-31-5VC-0000-1250
Property Address: 3773 CRAWLEY DOWN LOOP SANFORD, FL 32773
Value Summary
2018 Working
Values
2017 Certified
Values
Valuation Method Cost/Market
0
Cost/Market
0
14,000
14,600
0
Number of Buildings
Depreciated Bldg Value
Depreciated EXFT Value
14,000LandValue (Market)
Land Value Ag
Just/Market Value "" 14,000
Portability AdjSaveOurOurHomesAdj0
T
Amendment 1 Adj 0 0
P&G Adj 0 _ 0
Assessed Value 14,000 14,000
Tax Amount without SOH: $266.58
2017 Tax Bill Amount $266.58
Tax Estimator
Save Our Homes Savings: $0.00
Does NOT INCLUDE Non Ad Valorem Assessments
Legal Description
LOT 125
KENSINGTON RESERVE
PB 81 PGS 86-92
Taxes
Taxing Authority Assessment Value Exempt Values Taxable Value
County General Fund 14,000 0 $14,000
Schools — 14,000 0 $14,000
City Sanford 14,000 0 $14,000
SJWM(Saint Johns Water Management) ^ 14,000 so _ $14,000
County Bonds 14,000 0 i $14,000
Sales
Description Date Book Page Amount Qualified Vac/Imp
No Sales
Fond Comparable Sales
Land
Method Frontage Depth Units Units Price Land Value
LOT 1 1 $14,000.00 14,000
Building Information
Permits _ 1
Permit # Description Agency Amount CO Date Permit Date
http://parceidetail.scpafl.org/ParcelDetaillnfo.aspx?PID=1720315VC0000125O 1/2
2/15/2018 SCPA Parcel View: 17-20-31-5VC-0000-1250
No Permits
Extra Features
Description Year Built Units Value New Cost
No Extra Features
http://parceidetail.scpafl.org/Parcel Detail lnfo.aspx?PID=1720315VC00001250 2/2
LIMITED POWER OF ATTORNEY
Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford,
Seminole County, Winter Springs
Date:
I hereby name and appoint: Tracy McDonald
an agent of: NVR Inc., dba Ryan Homes
Name of Company)
to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things
necessary to this appointment for (check only one option):
The specific pe it and appli ation for work located at:
S eet Address)
Expiration Date for This Limited Power of Attorney
License Holder Name: Robert Lattanzi
State License Number:
Signature of License H
STATE OF FLORIDA
COUNTY OF Orange
May 20,2018
The foregoing instrument was acknowledged before me this VS day of
200 L9 , by Robert Lattanzi who is ® ersonal y known}
rtome or who has produced as
identification and who did (did not) take an oath.
Notary Seal)
MEAGAN LYNNE FOWLER
t,4Y COMMISSION # GG 063253
N Q EXPIRES. January 17.2021
jS'
Qp F7 Bonded Thru Budget Notary Sernces
Rev. 08.12)
Signature
MEAD" V(NNC- FoWU&2
Print or type name
Notary Public -State of FwR VtOA Commission
No. My
Commission Expires: 4kN 11, U 7-1
SQ.FT. CALC.]S
15T FLR LIVING W4 SO. FT.
2ND PLR. LIVING 1,265 SO1. FT.
TOTAL LIVING 2,165 Sa FT.
ENTRY 40 5a FT.
GARAGE 449 SQ FT.
LANAI O2. 260 SFT. TOTAL
2,918 SOL FT. GOIPONE
Nf AM C1AMM WIND LOADS BASIC WIND EWOBIItE FOR •
BEOCID QUISM CALL •
votitFt
am ZONE
16S WHI WIND N
R AGEDESTION1
112 16 - '
X -0 1w. 84- 5 24E0/-30.16 2
24 BOW DR 36' 4 21.15/-3605 3
33 2) 25-SH 16, 63' 5 21D/-34W 4
64 60W 660 14' 1 5 1 2631/-33.30 WIND
DESIGN CRITERIA A-
BASIC WIND SPEED MPH (3 SECOND GUST) VULT=
150 / VASD=116 MPH B.
INTERNAL PRESSURE COEFFICENT= .IS G.
RISK CATEGORY -TYPE II D.
EXPOSURE CATEGORY C NOTE:
VALUES
FOR COMPONENTS 4 CLADDING PRESSURE ARE BASED ON THE
V'It DESIGN WIND SPEED. FBCR 6TH ED. (2011) ALLOWS THESE PRESSURES
TO BE MULTIPLIED BY 0b TO MEET THE ALLOWABLE OR NOMINAL
TESTED VALUES USED BY PRODUCT MANUFACTURER5. NO1E
L
PRIOR TO DRnUALL kaTALLATION ON ALL FRAMPG M VERB 2'-0' FRCI'I THE FNISH FLOOR
WALL SE SPRAYED AID TREATED UV'BORATE' A TERM TF£.ATED SPRAY PWDR,
3
I/2' 2
TOP
K
2x4I=
FROIED K'
OL A
CABINET
SECTION 3/
4' TKG, SUe FLOOR GLUED 4 BCFEUED PER NAILING CCHEDULE PRE-
EIY FL.R iRJSSES PER TRIES PLAN 12)
LAYERS OF 3/4' PLYWOOD OR (2) LAYERS OF 314'
SUB FLOOR MATERIAL RIPS FOR SOLID NAILING BEELIKE
2x12 STRINGER TO SOLID NAILING W/ 12d NAILS
TO BE NAILED FROM BACKSIDE U
W.I.C. 10,
1\
FOYER STAIIi
DATA: 17
RL9ERS 07.57" 16
TREADS 010" +1" NOSING 1 /
4' v
L rb
V+tYJNG 2x4
P.T. PLATE 6EELRE W/ IOd OUT NAILS VW O.C. MAX STAIR
SECTION: 99 49 9 BRG.
HT. 1
SCALE: 1/2 - P-0' 10'-
8 3/4' RIND, 4
FIN FLRh
S'-4' 5Rf.. HT. Y
42'
HIGH I UNLL 3)
2xT2 SYP STRINGERS SECJRED W/ I2d
NAILS . 6'-$' OL. 2x12
S.YP. TREAD 2
4 RE-INFORCING • EA 2.12 STRINGER
3'
KICKPLATE 2.
12 STRINGER TO SIT ON LANDIW.. BEYOND)
3/
4' G SUB CA FLOORGLUED4 NAILED
D13L
2xb LEDGER SECURED TO BLOCK
W/ SAS' TAP CONS MIN.
I V4' EMB. 24'
O.O. STAGGERED o
0-0' FIN. FLR e
s
7
FED
SING 41 S'-
44- gam. Xb
P.T. PO6i LV W. x6 P.T. POST V LLD. U.
RAP TO 1'-8' AFF. WRAP TO T-V AFF. TO
I1ATQ4 BOX
B CO
TO
NATOH COL
U.IDTH 26'LANAI -
O'
xl0'-0' I
V-4' O4 I I
I
3'-
8' I I
I I
I I
I 2)
25-614 6080 W-0owl
I I I 1101 O -
0-- GREAT
ROOM 28'-
4'xl5'-0' 3'-
4' Otx 4X6
4X6
POST A POST C
j e
snx ETITCHEN
o 4-
SH PANTRY
Be
TIII 3'-
4' O_& n mlll MUD ROOM T
T T-4'Ori j
fFOYER
w4l
CIA oPr.
DBL
STUD KT. o
MIXILDRY] V', b, T
n. uWVE TO
EXTERIOR 7
2
CAR GARAGE 20'
9'
CLr. 0_
4' 6'-
8' '-0' II'-6' 4'-0' 5'-10' ENTRY
9'-
4' CLCx 0
F6 a
LINE
l: 2ND FLOOR ABOVE 16'-
0' x 1'-0' 04W O
FIRST
FLOOR PLAN SCALE:
1/4 = I'-0' ELEVATION 'A' L
v
9
A
R C X IT E C T E Design
Grou
h. 1441
N. RONALD RFACAN BLVD. LONGWOOD,
FL 32T50 PH:
407-7746078 FP%:
40T-T7q-0OTB www.
eEtlasigngroup.mm AA #:
0003325 II
J ommi
L:
J sysDiv.
ae IAT: KENSINGTON
RESERVE
LOT
125) MODAL•
LARGO
VERSION#
01) PROJ'
ECTTjT: 02997.
000 PAGE:
FIRST
FLOOR
PLAN
ARCHITECT:
STATE
OF RORDA DATE:
1 /11 /18 9
HffiET OF
9
OCWCNEPfr AND CLADDM WND LOADS BA9C YItO E)POWE
FCA 3 £CQO OJSfB
CALL# SMWE TlTKN ZC/E 90 LFH VIANDwontAGEDELsarr
I 30
I)3051-SH lI' 61' 5 I9bI/-3815
EGW55 TEMP
I 6
3051 TEP4''
36' 61, 5 I8b5/-31B5
SS
3 I5 16. 61, 4 I8b5/-31A
4 6 36' 61' 5 I8b5/-3125E
4A 6 36' 61' 4 I8b5/-3114E66
5 @ 36' 48' 5 39051-38.T0TRIP
6 6 I- 36' 61' 4 I865/-31A
WIND DESIGN CRITERIA
A. BASIC WIND SPEED MPH (3 SECOND GUST)
VULT=150 / VASD=116 MPH
B. INTERNAL PRESSURE COEFFICENT.. JS
C. RISK CATEGORT-.TYPE II
D. EXPOSU I;E CATEGORY O
NOTE:
VALUES FOR COMPONENTS / CLADDING PRESSURE ARE BASED ON
THE wlt DE5KaN WIND SPEED. P5CR 6TH ED. (201-1) ALLOUI6 THESE
PRESWRE5 TO BE MULTIPLIED BY 0.6 TO MEET THE ALLOWABLE OR
NOMINAL TESTED VALUES USED BY PRODUCT MANIFACTURERS.
NOTE: L PRIOR TO DRYWALL MSTALLATICN ON ALL FR4MMG 1101BERb 1'-0' FROM THE FINISH
FLOOR WLL BE SPRAYED AND TREATED W/'BORATE' A TEI"TE TREATED SPRAT
PI/DR.
3/4' TIC= SIB FLOOR GLUED l SCREWED PER NAILING SCHEDULE
PlE-ENO. RR TRIS.SEB PER 7l2J88 FLAN
IV LAYERS OF 3/4' 1Ylli00D OR 01 LAYERS OF
3/4' SUB FLOOR MATERIAL RIPS FOR SOLID NAILING
SECURE 1,11 STRINGER TO SOLID NAILING W/ 12d
NAILS TO BE NAILED Flital BACKSIDE
Y.I.C.
Im'
FOYER
w Q _
STAM DATA:
17 RISERS 07.57"
10 TREADS 010" +1" NOSING
bb Loom
1x4 P.T. ELATE SECURE W/ 10d CUT NAILS *'Or-, MAX
TAIR SECTION: 9'-4" BRG. HT.
Al F. 1/2 = P-0'
A 10'-5 3/4' 2ND.
ON. PLR-
BFYa. MT.
41' HK4J { WALL
3) 2.12 SYP STRINGERS SECURED W/
Dd NAILS • 6'-S' OL.
2.12 S.Y.P. TREAD
1x4 RE -REPRICING • EA 2.12
STRINGER
1' KICKPLATE
2W2 STRINGER TO SIT ON LANDING
BEYOND)
314. TICx SUB FLOOR GLUED 1
NAILED
D5L 1x6 LEDGER SECURED TO
BLOCK W/ 3/16' TAP DONS
MR1 11/4' ENS.
24' O.G. STAGGERED
a 0'-0' FIN. PLR
I PE /P LAT
SECOND FLOOR PLAN
SCALE: 1/4 = 1'-0' ELEVATION 'A'
4X4
POST
e
N
m
A R C H IT E C T S
Design
GrOU I..
141 N. RONALD REAGAN BLVD.
LO NGWOOD, FL32TS
PH: 407-77"078
FAXA07-7T44078
w w.aetlesigngmup.mmwP/1 M: 0003325
a
F
h
A
Q
8
E
0
r
c
t
Suu;nrv. & LOT:
KENSINGTON
RESERVE
LOT 125)
MODEL -
LARGO
VERSION#01)
PROJECT#:
02997.000
PACK:
SECOND
FLOOR PLAN
ELA)
ARCHITECT
STATE OF FLORDA
DATE: 1 /11 /19
SCALE: 1/4"=1'-O"
SKEET
4 OF 9
15 lightyears, Inc
776 Bennett Drive
Longwood, Florida 32750
June 1, 2018
To: Local Building Department
Cf— O—kJ LL.,-f
15
RE: Blower Door Test & Duct Leakage Test Reports
To whom it may concern,
Lo l8~91g lig htye
a rs This letter
is to request that the attached forms be accepted for compliance of the 2017 Florida Building Code statute
R402.4.1.2 Envelope leakage testing (Blower Door Testing) and R403.3.3 Duct testing. The attached
forms were provided by the Florida Building Commission as the accepted forms to be submitted. These
forms are listed on the 2017 Florida Building Code, Energy Conservation Technical Assistance Manual,
Document Number: TAM-2017-1.0, released February 02, 2018, pages R-78 through R-80 (
page numbers 159-161). Web link
provided for quick access to the TAM document https://tinyuri.com/2017FBC-TAM These forms
meet all three required Residential Energy Efficiency Compliance Paths listed under R401.2, Prescriptive, Performance,
and Energy Rating Index (ERI) paths. We are
working with building departments across Florida to standardized the form submittal process and would like
your department to allow these forms to meet compliance. If there are any issues with accepting these
forms, please reach out to me directly and I will ensure that we submit any specific form that you
will require. Tim Smith (407)-951-3236 tsmith@151ightyears.com Respectfully, Timothy`-
15
Lightyears,
Chief Operations Officer Energy Technical
Advisor RESNET Quality
Assurance Designee IECC Residential
Energy Inspector/ Plans Examiner Member, Building
Officials Association of Florida Member and Code Development Committee participating member.
Also, representative to the Florida Building Commissions, Energy Technical Advisory Committee
for the BOAF- CDC
Builder: gvd,. Community:
J ( &va2L t:
Address: Unit:
City: 5 State: A, Zip: v< i
System 1
cfm25
System 2
cfm25
System 3 cfm25
Sum of any
additional systems cfm25
Total of all
systems L= cfm25
Company Name: 15 Lightyears, Inc Phone: 855-438-1515
1 hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy
Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test: v ° /)O /`
Printed Name of Tester: Dylan Tindall
License/Certification #: 3766919 Issuing Authority:
RESNET
Copy of License / Certificate of the tester must be attached)
Company Name: 15 Lightyears, inc Phone: 855-438-1515
1 hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy
Conservation requirements accordingto the co Hance method selected above.
Signature of Tester: Date of Test:
V NJ
Printed Name of Tester: Dylan Tindall
License/Certification #: 3766919 Issuing Authority:
RESNET
Copy of License / Certificate of the tester must be attached)
r_
CITY OF SANi=ORD
BUILDING & FIRE PREVENTION
Pill PERMIT APPLICATION
Application No:
Documented Construction Value: _
Q 33
Jab Address: _J 9 Historic District: Yes No
Parcel ID:
ResidentiatqCommercial
Type of Work: 1\' " Addition Alteration Repair Demo Change'of Use move
Description of Work: J\\,/ WY) J
Plan Review Contact Person: Title:
Phone: Fax: Email:
Property Owner Information
Name l K-' f
Phone-,1fl
Street: ' Resident of -property.: %\
City, State Zip;
n
1
Contractor Information
D (', yt, l Phone: t(_
Street; 75 Jac Fax: L] 1.2 - RQ, -'
c ?
r 7d/" / , City, State Zip: '
f '
7
i State License Na:
Architect/Engineer Information
Name: Phone:
Street: Fax:
City, St, Zip: E-mail:
Bonding Company: Mortgage Lender:
Address: Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE, OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a pert -nit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shalt be inscribed with the date of application and the code in effect as of that date: 5t° Edition (2014) Florida Building Code
Revised: June30, 2015 Permit Application
A" I
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may befoundinthepublicrecordsofthiscounty, and there maybe additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should "calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be, done in compliance with all applicable laws regulating construction and zoning.
Signature of owner/Agent Date
Print Owner/Agent's Name
Signature of Notary -State of Florida Date
Owner/Agentis Personally Known to Me or
Produced ID Type of ID
WP'ature of Contractor/Agent Date
P! nt C ntractor/}Agent's Name
Signatl rf Notary-5tatc of Florida Datc
ra"
Iky PUel,
n,
PAMEiAS TERNUS
Commission # GG110622
dpy Expires August 7, 2021' N
lFUf rLV'
tl4
Bonded Th. aedget 4`iotarX$91vl8S
Contractor/Agent iS ;Personally Known toMe.or
Produced ID T e of ID
Permits Required: Building[] Electrical Mechanical[] Plumbing[] Gas Roof
Construction Type Occupancy Use: Flood Zone:
Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories:
New Construction: Electric - # of Amps Plumbing - # of Fixtures
Fire Sprinkler Permit: Yes NoEl # of Heads Fire Alarm Permit: Yes NoEl APPROVALS:
ZONING: UTILITIES: WASTE WATER: ENGINEERING:
COMMENTS:
FIRE:
BUILDING: Revised:
June 30, 2015 Permit Application
L1
CITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
Application No: c' 1
Documented Construction Value: $ "I .
G
Job Address: Lk
Parcel ID:
Historic District: Yes No 0
Residential Commercial
Type of Work: New Addition Alteration Repair Demo Change of Use Move
Description of Wor : Plumbing; New Residential Construction
Plan Review Contact Person: Khrissy or Jamie Title: Clerical
Phone: 407-323-7515 Fax: 407-323-8954 Email: info malpi-orlando.com
S
Property Owner Information
Name Phone:
Street: Resident of property?
City, State Zip:
Contractor Information
Name Advantage Plumbing, Inc. Phone:
Street: PO Box 1117
Fax:
City, State Zip: Sanford, FL 32772
Name:
Street:
City, St, Zip:
Bonding Company:
Address:
407-323-7515
407-323-8954
State License No.: CF-0057881
Architect/Engineer Information
Phone:
Fax:
E-mail: _
Mortgage Lender:
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a.permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51h Edition (2014) Florida Building Code
Revised: June 30, 2015 Permit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may befoundinthepublicrecordsofthiscounty, and there may be additional permits required from other governmental entities such as watermanagementdistricts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is requiredinordertocalculateaplanreviewchargeandwillbeconsideredtheestimatedconstructionvalueofthejobatthetimeofsubmittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, inaccordancewithlocalordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in campliance with all applicable laws regulating construction and zoning.
Satoie of Qwnt rlAgent late
PrintiOwner/Ageirt's Name
Signature ofNotary-State of Florida
Owner/Agent is Personally Known to Me
or Produced ID Type of ID
Signature of ContractorlAgent to .
A. Thomas Smith
Prim Contractor/Age ni's Name
Sigaa pre o otary- M ofthFlLnda
m sM0 DateWei
NOTARY PUBLIC
STATE OF FLORIDA
Canmg GG136M
a,e Expires 80/2021
Contractor/Agent is X Personally Known to Me or
Produced ID Type of 1D
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building Electrical Mechanical Plumbing[] Gas Roof
Construction Type: Occupancy Use: Flood Zone:
Total Sq Ft of Bldg: Min. Occupancy Load: I # of Stories:
New Construction: Electric - # of Amps Plumbing - # of Fixtures
Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No
APPROVALS: ZONING: _ UTILITIES:
a WASTE WATER
ENGINEERING:
CON EWENTS:
FIRE: BUILDING:
Revised: June 30, 2015
Permit Application
CITY OF SANFORD
BUILDING,& FIRE. 'PREVENTION
PERMITAPPLICATION Application
No: Documented
Construction Value: S - Job
Address: , a- ` Hlstbre Uistrtct:. Yes Parcel
ID: Resideilti Connmercial Type
of Work: N_ 6ivP_- Addition Alteration Repair DemoEl .Change of Use El Moye 11 Description of
Work: t Plan Review
Contact Person: Phone: t _
Name _
Street: ! "
City,
State
Zip: Name Street:
City,
State
Zip: Title:. 34
03
Email:kac&Llnjb i c. ty Owner
Information Phone: Resident
of
property? :. ` State License
No.: CA 8 Q 0 Architect/Engineer
Information Name: Phone:
Street: Fax:
City, St,
Zip: E-mail: Bonding Company:
Address: Mortgage
Lender:
Address: WARNING
TO
OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. ' A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application
is
hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior
to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this
jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers,
heaters, tanks, and air conditioners, etc. FBC 105.
3 Shall be inscribed with the date of application and the code in effect as of that date: 5!h Edition (2014) Florida Building Code Revised: June
30, 2015 Permit Application
NOTICE- In°addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in'the public records of this county, and there may be additional permits requiredfrom other governmental entities such as water management
districts, state agencies, or federal agencies. Acceptance
of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The
City of Sanford requires payment of a plan review fee at the time of permit. submittal. A copy of the executed contract is required in
order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The
actual, construction value will be figured bascd on the current' ICC Valuation Table in effect at the time the permit is issued, in accordance
with .,local ordinance. .Should =calculated charges, figured off the executed contract exceed the actual construction value, credit.
wilI be applied toypur permit,fecs,when the permit is, isstted. OWNER'
S ; +F.IDAVIT: I certify that all of the foregoing information is accurate la t work will be
done in compliance with alI applicable flaws :regulating: construction and 70 g,- Signature
of Owner/Agent Date Sig rc of Contractor/Agent I" ta_ Print
Owner/Agent's Name P ' t=Contractor/A ent's Name SignatureofNotary-
State of Florida Date Signature of No ry-$tatCofFlorida mte' CHERYL
D AKERS A. MY
COMMISSION # FF998962 mEXPIRES
June 05, 2020 d07
A8-0sa aorre„Hokvysarvkc"cnm_ _ Owner/
Agent is Personally Known to Me, or Corittactor/)`gent, is _Personally Knownto.Me or Produced
ID Type of ID Produced ID .._.._ Type of ID 4 9
v e BELOW
IS FOR OFFICE USE ONLY Permits
Required: Building Electrical Mechanical Plumbing[] 'Gas[] Roof Construction
Type: Occupancy Use: _ Flood Zone: Total
Sq Ft of Bldg: Min. Occupancy Load: # of Stories:..... New
Construction: Electric - # of Amps Plumbing - # of Fixtures Fire
Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS:
ZONING UTILITIES: WASTE WATER: ENGINEERING:
FIRE: BUILDING: COMMENTS:
r Revised_
June 30, 2015 Permit Application
STATEWIDE State Cert CAC032448
1-888-831-2665 EL -A
Irt/I
JASMINE, COVE VERSION 1 OPT
LUXURY OWNER'S SUITE 3.0 15.0 3 1$4,6,()4.00'
JASMINE COVE VERSION 1 OPT
SITTING RM 3.0 15.0 3 4,509.00
LARGO
LAUDERDALE
3.0
3.5
15.0
15.0
4 -
3
5,530.00
4,878.66
LAUDERDALE OPT BONUS 5.0 15.0 3 6,733.06
LAUDERDALE OPT BONUS BATH 5.0 15.0 4 6,818.00
LAUDERDALE OPT BONUS BDRM 5.0 15.0 4 6,929.00
PALMDALE 2.0 / 2.5 15.0 4 8,029'.00
PONTE VEDRA 2.5 15.0 3 4,712.00
SANDPIPER POINT VERSION 2 3.0 15.0 2 4;250.00
SANDPIPER POINT VERSION 2 OPT
1 ST FL BDRM/BDRM 5 _ 3.0 15.0 3 4,3£99 00
SANDPIPER POINT VERSION 2 OPT
LUXURY OWNER'S SUITE BATH, _ , 3.5. 15.0 3,4,901.00
SANDPIPER POINT VERSION-2-OPT
OWNER'S BATH _ 3.0 15.0 2
SANDPIPER POINT VERSION 2 OPT'
SITTING RM 3.5 15.0 2 4,6600
SANDPIPER POINT"VERSION 2 OPT
STUDY 3.0 15.0 2 45333.00
SANIBEL VERSION 1 2.0 / 2.5 15.0 4 8,098.00
SANIBEL VERSION 1 OPT I ST FL
BDRM 2..512.5 15.0 5 750.00 „
SANIBEL VERSION 1 OPT BATH 2 2.0 / 2.5 15.0 5 8,213.6
SANIBEL VERSION 1 OPT GUEST
SUITE 2.5 / 2.5 15.0 ' 5 9,406.00
SANIBEL VERSION 1 OPT MORNING
RM 2.5 / 2.5 15.0 4 8,455.00
SANIBEL VERSION 1 OPT STUDY 2.0 / 2.5 15.0 4 8,200.00
SANTA ROSA _ _ 3.5 15.0 4 5,496,OU
SANTA ROSA OPT BDRM 4 3.5 15.0 4 51526.0:0
SANTA ROSA OPT MORNING RM 3.5 15.0 4 5,600.00
SANTA ROSA OPT STUDY 3.5 15.0 4 51581.6,0
SAWGRASS 3.5 / 2.0 15.0 4 9,232.00,
SAWGRASS OPT 1ST FL SUITE 3.5 / 2.0 15.0 5 9,485.00
SAWGRASS OPT 2ND FL EXTENSION 3.0/3.0 115.0 5 9,725.00
SAWGRASS OPT BATH 2 3.5 / 2.0 15.0 5 9-248.00
SAWGRASS OPT BONUS BDRM 3.5 / 2.0 115.0 14 9,222.00
11% %C
5.11 COI)IS(O
41171 3,134 001.
DESCRIPTION AS FURNISHED: Lot '125, KENSINGTON , RESERVE, as recorded in Plat Book 81, Pages 86
through 92, Public Records of Seminole County, Florida.
BOUNDARY FOR / CERTIFIED TO: Morisela Cinor; NVR Inc. dbo Ryan Homes; Stewart Title Guaranty
Company; NVR Settlement Services, Inc.; NVRM
TRACT J
POND-O
REC, 112" I,R. N 00019 09 W
REC. 112" I.R.
NO I.D. 50.00 j 4596
J
0
9
0.
s-
C?,
h
I
7
31.80'
41.80'
LOT 125
o j
26.0'
3.5'x3.5'
o COO CONNC.
C. AC
PAD 5.
00' 15.00' 30.
0' LOT
126 03Co
LOT
124 p
0
o TWO
STORY p p RESIDENCE
F.
F.= 31.04' n
p y
p
U1 7
C6 7 vI 377
3 C COV'
D. 5.
00" 8.
7 BRICK i
8.
7' o 21.
3' 15,00' BRICK
16 WALK
BRICK DR.
25.
20 5.20' 10'
UTIL 9ry^ P.C. LOT Ap,
ESMT. 9* 36 LOT 247_ 121 4'
CONC. WALK REC. 112" I.R. REC.
112' I.R. NO I.D. INO
I.D. ONLINE B.B.) ITT 00o19 Q,9 W ONLINE 50.
00' CRA
TrLEY _D 0 TAN L OOP 50'
WIDE PRIVATE R/W) 1?
G
G BUILDING
SETBACKS: AS FURNISHED PROPOSED =
FINSHED SPOT GRADE ELEVATIONS FRONT = 25' PER
DRAINAGE PLANS PLOT PLAN AREA CALCULATIONS REAR = 20' PROPOSED
DRAINAGE FLOW IMPERVIOUS COVERAGE = 2,113f SQUARE FEET OR 36.71 SIDE = 5' FOR 40' LOTS FOR
60' LOTS LOT
GRADING TYPE 8 p 0 LOT
CONTAINS 5,750f SQUARE FEET SIDE = 7.5' OQ
LIVING AREA CONTAINS 1,353t SQUARE FEET SIDE = 10' FOR 75' LOTS PROPOSED
FINISH FLOOR PER PLANS = 31.0, QQ CONC/LANAI/PORCH CONTAINS 760t SQUARE FEET SIDE STREET = 25' GRUSEjVffErEJ?-
ISCOTT ASSOC, INC. - LAND ,SURVEYORS LEGEND -
LEGEND - 5400
E. COLONIAL DR. ORLANDO, FL. 32807 (407)-277-3232 FAX (407)-658- 1436 P =
PLAT F =
FIELD LP. =
IRON PIPE PA.
L. POINT ON LINE TYP,
TYPICAL PRO. =
POINT OF REVERSE CURVATURE NOTES:
1.
THE UNDERSIGNED DOES HEREBY CERTIFY THAT THIS SURVEY MEETS THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF I.
R, IRON ROD P,C.C. • POINT OF COMPOUND CURVATURE PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER 5J-17 FLORIDA ADMINISTRATIVE CODE PURSUANT TO SECTION 472.027, FLORIDA STATUES C.
M. = CONCRETE MONUMENT RAD. = RADIAL 2, UNLESS EMBOSSED WITH SURVEYOR'S SIGNATURE AND ORIGINAL RAISED SEAL, THIS SURVEY MAP OR COPIES ARE NOT VALID. SET
I.R. 1/2' IR. w/NLB 4596 MR. NON -RADIAL WP.
WITNESS POINT 3. THIS SURVEY WAS PREPARED FROM TITLE INFORMATION FURNISHED TO THE SURVEYOR, THERE MAY BE OTHER RESTRICTIONS REC. =
RECOVERED P.
O.B. = POINT OF BEGINNING P,
OC. = POINT OF COMMENCEMENT CALC. = CALCULATED
P.R.
M.^ PERMANENT REFERENCE MONUMENT OR EASEMENTS
THAT AFFECT THIS' PROPERTY. 4. NO
UNDERGROUND IMPROVEMENTS HAVE .BEEN LOCATED UNLESS OTHERWISE SHOWN. Q = CENTERLINE
FF. FINISHED FLOOR ELEVATION 5. THIS SURVEY IS PP,EPAREO FOR THE SOLE BENEFIT OF THOSE CERTIFIED TO AND SHOULD NOT BE RELIED UPON BY ANY OTHER ENTITI'. NLO NAIL
B DISK B.SL. BUILDING SETBACK LINE 6. DIMENSIONS SHOW"L FOR T.'IE LOCATION OF IMPROVEMENTS HEREON SHOULD NOT BE USED TO RECONSTRUCT BOUNDARY LINES. R/W
RIGHT-OF-WAY B.M. BENCHMARK B.B.
BASE BEARING 7. BEARINGS, ARE, EASED ASSUMED, DATUM AND ON THE LINE SHOWN AS BASE BEARING (B.B.) ESMT. = EASEMENTS. ELEVATIONS, IF SHOWN, ARE BASED. ON NATIONAL GEODETIC VERTICAL DATUM OF 1929, UNLESS OTHERWISE NOTED. DRAIN, DRAINAGEUTIL. UTILITY
CL,FC.
CHAIN LINK FENCE 9. CERTIFICATE
OF AUTHORIZATION No. 4596, - WD.FC.
WOOD FENCE C/B =
CONCRETE BLOCK SCALE M- 1" = 20' DRAWN BY:— p,C,
POINT OF CURVATURE P.T. =
POINT OF TANGENCY CERTIFIED BY: DATE ORDER
NO. DESC. DESCRIPTION
RADIUS PLOT
PLAN 12-05-2017 5378-17 R L =
ARCLENGTH PLOT PLAN 12-22-2017 5819-17 D = DELTA
CHORD FORFOUNDATION/ELEVS. 04-30-18 2612-18 C B. =
CHORD BEARING NORTH FINAL
ELEVS. 07-23-2018 IELEV 4673-18 THIS BUILDING/
PROPERTY DOES NOT LIE WITHIN r - A
R.L.
S. 4714 THE ESTABLISHED
100 YEAR FLOOD PLANE AS PER "FIRM" T GRUSEN
EVER, H 4801 ZONE "
X"
MAP j 12117C0090F (09-28-07) JA W.
SCO R.LS t
FORM R405-2017 RECORD COPY
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot125KensingtonReserveLargoAGR Builder Name: RYAN HOMES LDIANG
Street: 3773 CRAWLEY DOWN LOOP Permit Office: SANFORD
City, State, Zip: SANFORD , FL, 32773 Permit Number _ 8 SANFORD
Owner:
Location: FL, Orlando
Jurisdiction: 91 0DesignCounty:: Seminole (Florida Climate Zone 2)
4R
1. New construction or existing New (From Plans) 9. Wall Types (2524.0 sqft.) Insulation Area
2. Single family or multiple family Single-family
a. Frame - Wood, Exterior R=13.0 1208.00 ft2
b. Concrete Block - Int Insul, Exterior R=4.1 966.00 ft2
3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 350.00 ft2
4. Number of Bedrooms 4 d. N/A R= ft2
10. Ceiling Types (1301.0 sqft.) Insulation Area
5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1301.00 ft2
6. Conditioned floor area above grade (ft2) 2154 b. N/A R= ft2
Conditioned floor area below grade (ft2) 0
c.
11. Ducts R=
ft2 R
ft2 7.
Windows(231.5 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 430.8 a.
U-Factor: Dbl, U=0.35 183.50 ft2 SHGC:
SHGC=0.29 b.
U-Factor: Dbl, U=0.62 48.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC:
SHGC=0.29 a.
Central Unit 34.8 SEER:15.00 c.
U-Factor: N/A ft2 SHGC:
13. Heating systems kBtu/hr Efficiency d.
U-Factor: N/A ft2 a. Electric Heat Pump 32.6 HSPF:8.50 SHGC:
Area
Weighted Average Overhang Depth: 3.073 ft. Area
Weighted Average SHGC: 0.290 14. Hot water systems a.
Electric Cap: 50 gallons 8.
Floor Types (1301.0 sqft.) Insulation Area EF: 0.950 a.
Slab -On -Grade Edge Insulation R=0.0 904.00 ft2 b. Conservation features b.
Floor over Garage R=11.0 397.00 ft2 None c.
N/A R= ft2 15. Credits Pstat Total
Proposed Modified Loads: 63.48 Glass/
Floor Area: 0.107 P q SS PASSTotal
Baseline Loads: 64.82 I
hereby certify that the plans ands cifications covered by Review of the plans and i`f1iE Srq?, this
calculation are in compliance th the Florida Energy specifications covered by this Code.
calculation indicates compliance with
the Florida Energy Code. t++ri PREPARED
BY: ~ "'T
Before construction is completed DATE:
2-6-1 R Scott Pratt this building will be inspected for compliance
with Section 553.908 0
I
hereby certify that this buildi g, as designed, is in compliance Florida
Statutes. with
the Florida Energ Co OWNER/
AGENT: BUILDING OFFICIAL: ! DATE:
DATE: 3 Zit$ Compliance
requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified
factory -sealed in accordance with R403.3.2.1. Compliance
requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope
leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Compliance
with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested
in accordance with ANSURESNET/ICC 380, is not greater than 0.060 Qn for whole house. 2/
6/2018 6:44 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017
PROJECT
Title:
Building Type:
Owner Name:
of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot125KensingtonReserveLar Bedrooms: 4
User Conditioned Area: 2154
Total Stories: 2
1 Worst Case: No
RYAN HOMES Rotate Angle: 0
SANFORD Cross Ventilation: No
691500 Whole House Fan: No
Single-family
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
125
KENSINGTON RESE
3773 CRAWLEY DOW
Seminole
SANFORD ,
FL , 32773
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Orlando FL_ORLANDO_INTL_AR 41 91 70 75 526 44 Medium
BLOCKS
Number Name Area Volume
1 Block1 2154 18309
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 2154 18309 Yes 5 4 1 Yes Yes Yes
FLOORS
Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Floor over Garage Main ---- ----
2 Slab -On -Grade Edge Insulatio Main 103.5 ft
397 ft2
904 ft2
11 0.16 0 0.84
0.39 0 0.61
ROOF
v # Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1 Gable or Shed Composition shingles 1371 ft2 216 ft2 Medium 0.85 N 0.85 No 0 18.4
ATTIC
V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC
1 Full attic Vented 300 1301 ft2 N N
CEILING
Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic (Vented) Main 30 Blown 1301 ft2 0.11 Wood
2/6/2018 6:44 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017
WALLS
Adjacent
Wall Typ,FtSpaceCavR_Vaity Width Height Sheathing Framing Solar Belowo
1 N Exterior Frame - Wood Main 13 45 6 8 0 364.0 ft2 0 0.23 0.6 0
2 N Exterior Concrete Block - Int Insul Main 4.1 27 0 9 4 252.0 ft2 0 0 0.6 0
3 E Exterior Frame - Wood Main 13 30 0 8 0 240.0 ft2 0 0.23 0.6 0
4 E Exterior Concrete Block - Int Insul Main 4.1 8 6 9 4 79.3 ft2 0 0 0.6 0
5 S Exterior Frame - Wood Main 13 45 6 8 0 364.0 ft2 0 0.23 0.6 0
6 S Exterior Concrete Block - Int Insul Main 4.1 38 0 9 4 354.7 ft2 0 0 0.6 0
7 W Exterior Frame - Wood Main 13 30 0 8 0 240.0 ft2 0 0.23 0.6 0
8 W Exterior Concrete Block - Int Insul Main 4.1 12 0 9 4 112.0 ft2 0 0 0.6 0
9 Garage Frame - Wood Main 13 37 6 9 4 350.0 ft2 0 0.23 0.3 0
10 W Exterior Concrete Block - Int Insul Main 4.1 10 0 9 4 93.3 ft2 0 0 0.6 0
11 W Exterior Concrete Block - Int Insul Main 4.1 8 0 9 4 74.7 ft2 0 0 0.6 0
DOORS
Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E Insulated Main None 25 3 8 24 ft2
2 Wood Main None 25 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall Overhang
v Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N 1 Vinyl Low-E Double Yes 0.35 0.29 N 12.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5
2 N 1 Vinyl Low-E Double Yes 0.35 0.29 N 15.3 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5
3 E 3 Vinyl Low-E Double Yes 0.35 0.29 N 15.3 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5
4 E 3 Vinyl Low-E Double Yes 0.35 0.29 N 30.5 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5
5 S 5 Vinyl Low-E Double Yes 0.35 0.29 N 15.3 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5
6 W 7 Vinyl Low-E Double Yes 0.35 0.29 N 30.5 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5
7 W 11 Vinyl Low-E Double Yes 0.35 0.29 N 32.4 ft2 1 ft 0 in 10 ft 10 in Drapes/blinds Exterior 5
8 W 8 Metal Low-E Double Yes 0.62 0.29 N 48.0 ft2 11 ft 0 in 0 ft 6 in None Exterior 5
9 S 6 Vinyl Low-E Double Yes 0.35 0.29 N 32.4 ft2 1 ft 0 in 10 ft 10 in Drapes/blinds Exterior 5
GARAGE
Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 449 ft2 449 ft2 33 ft 9.3 ft 1
INFILTRATION
Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000378 2136.1 117.27 220.54 3398 7
2/6/2018 6:44 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017
HEATING SYSTEM
System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 32.6 kBtu/hr 1 sys#1
COOLING SYSTEM
System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 15 34.8 kBtu/hr 0 cfm 0.75 1 sys#1
HOT WATER SYSTEM
System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert Company Name System Model # Collector Model Area Volume FEF
None None ft2
DUCTS
Supply ---- Return ---- Air CFM 25 CFM25 HVAC #
v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 430.8 ft Attic 107.7 ft Proposed Qn Main cfm 129.2 cfm 0.06 0.60 1 1
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling[ j Jan Feb [[ ]Mar A r May [Xj Jun X Julf Au Se f Oct NovDecffHeatin[X] Jan Feb [X] Mar f APr May [ ]Jun Jul Aurj SePXj Oct X Nov X Dec
Ventin [ Jan [ Feb [X Mar X A r Ma [ ] Jun [ Jul Aug Se X Oct X Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
2/6/2018 6:44 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
3773 CRAWLEY DOWN LOOP, SANFORD, FL, 32773
1. New construction or existing New (From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family
a. Frame - Wood, Exterior R=13.0 1208.00 ft2
b. Concrete Block - Int Insul, Exterior R=4.1 966.00 ft2
3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 350.00 ft2
4. Number of Bedrooms 4 d. N/A R= ft2
5. Is this a worst case? No 10. Ceiling Types Insulation Area
a. Under Attic (Vented) R=30.0 1301.00 ft2
6. Conditioned floor area (ft2) 2154 b. N/A R= ft2
7. Windows" Description Area
c. N/A R= ft2
a. U-Factor: Dbl, U=0.35 183.50 ft2
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Main
R ft2
6 430.8
SHGC: SHGC=0.29
b. U-Factor: Dbl, U=0.62 48.00 ft2
SHGC: SHGC=0.29 12. Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a. Central Unit 34.8 SEER:15.00
SHGC:
d. U-Factor: N/A ft2
SHGC: 13. Heating systems kBtu/hr Efficiency
a. Electric Heat Pump 32.6 HSPF:8.50
Area Weighted Average Overhang Depth: 3.073 ft.
Area Weighted Average SHGC: 0.290
8. Floor Types Insulation Area 14. Hot water systems
a. Slab -On -Grade Edge Insulation R=0.0 904.00 ft2 a. Electric Cap: 50 gallons
EF: 0.95
b. Floor over Garage R=11.0 397.00 ft2
c. N/A R= ft2
b. Conservation features
None
15. Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code_comp jent features.
Builder Signature: Date: 2/7/2018
Address of New Home: 3773 Crawley Down Loop City/FL Zip: 32773
Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/6/2018 6:44 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 3773 CRAWLEY DOWN LOOP Permit Number:
SANFORD , FL, 32773
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory).The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing
methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended
weatherstripping or other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond
intended infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air Ieakagd/Vindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
2/6/2018 6:44 AM EnergyGauge@ USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C)
or below 55°F (13°C) shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
2/6/2018 6:44 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complian Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 '% inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38°C to 60oC).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy.When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM
CFM)
MINIMUM EFFICACY a
CFM/WATT)
AIRFLOW RATE MAXIMUIV
CFM)
Range hoods Any 2.8 cfm/watt Any
In -line fan Any 2.8 cfm/watt Any
Bathroom, utility room 10 1.4 cfm/watt 90
Bathroom, utility room 90 2.8 cfm/watt Any
For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916
2/6/2018 6:44 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50oF (10°C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF (4.8°C).
R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
2/6/2018 6:44 AM EnergyGauge(D USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas (Mandatofte energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights.
2/6/2018 6:44 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Lot125KensingtonReserve LargoAGR Builder Name: RYAN HOMES Street:
3773 CRAWLEY DOWN LOOP Permit Office: SANFORD City,
State, Zip: SANFORD , FL, 32773 Permit Number: Owner:
Jurisdiction: 691500 Design
Location: FL, Orlando COMPONENT
AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General
A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements
The
exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks
or joints in the air barrier shall be sealed. Ceiling/
attic The
air barrier in any dropped ceiling/soffit shall be aligned with The insulation ided ceiling/soffit n any droppedg /soffit the insulation and
any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop
down stairs or knee wall doors to unconditioned attic spaces
shall be sealed. Walls The junction
of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of
the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material
having a thermal resistance of R-3 per inch Knee walls shall
be sealed. minimum. Exterior thermal envelope
insulation for framed walls shall be installed
in substantial contact and continuous alignment with
the air barrier. Windows, skylights The
space between window/doorjambs and framing, and and doors skylights
and framing shall be sealed. Rim joists Rim
joists shall include the air barrier. Rim joists shall be insulated. Floors The air
barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to including insulation. maintain
permanent contact with the underside of above -garage subfloor
decking, or floor framing cavity insulation and cantilevered shall
be permitted to be in contact with the top side floors) of sheathing,
or continuous insulation installed on the underside of
floor framing and extends from the bottom to the
top of all perimeter floor framing members. Crawl space
walls
Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I
vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct
shafts, utility penetrations, and flue shafts opening to exterior or unconditioned
space shall be sealed. Batts in narrow
cavities shall be cut to fit, or narrow Narrow cavities cavities
shall be filled by insulation that on installation readily conforms
to the available cavity spaces. Garage separation
Air
sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed
light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed
to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms
to available space shall extend behind p'
p'no and wiring, Shower/tub The
air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall
tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box
or The air barrier shall be installed behind electrical or communication exterior walls boxes
or air -sealed boxes shall be installed. HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be sealed to
the sub -floor or drywall. Concealed When required
to be sealed, concealed fire sprinklers shall only be sprinklers sealed in
a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings. a. In addition,
inspection of log walls shall be in accordance with the provisions of ICC-400. 2/6/2018
6:44 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
t Manual S Compliance Report Job: LotlMensingtonReser...
wrightso1 `® Date: 7/25/2015
Entire House By: FJF
DEL -AIR HEATING & AIR CONDITIONING
w
o _ Project Information
For: RYAN HOMES
3701 CRAWLEY DOWN LOOP, SANFORD, FL32773
Design Conditions
Outdoor design DB: 92.5°F Sensible gain: 28247 Btuh Entering coil DB: 77.0°F
Outdoor design WB: 76.2°F Latent gain: 3973 Btuh Entering coil WB: 63.5°F
Indoor design DB: 75.0°F Total gain: 32220 Btuh
Indoor RH: 50% Estimated airflow: 1160 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASH
Manufacturer: Goodman Mfg.
Actual airflow: 1160 cfm
Sensible capacity: 28936 Btuh
Latent capacity: 4738 Btuh
Total capacity: 33674 Btuh
Design Conditions
Outdoor design DB: 42.30F
Indoor design DB: 70.0°F
Model: GSZ140361K+ASPT47D14A
102% of load
119% of load
105% of load S H R : 86%
Heat loss: 23283 Btuh
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Goodman Mfg. Model: GSZ140361 K+ASPT47D14A
Actual airflow: 1160 cfm
Output capacity: 32112 Btuh 138% of load
Supplemental heat required: 0 Btuh
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1160 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 OF
Meets are all requirements of ACCA Manual S.
Entering coil DB: 69.4°F
Capacity balance: 34 IF
Economic balance: -99 OF
2018-Jan-13 11:02:55
t wrightSOW Right -Suite® Universal 2017 17.0.23 RSU23828 Page 1
A+CK ...veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MJ8 House faces: E
1.t$06 ` fa.® Component Constructions Job: Lot137KensingtonReser...
H/i191 i 6 Date: 7/25/2015
Entire House By: FJF
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM
For: RYAN HOMES
3701 CRAWLEY DOWN LOOP, SANFORD, FL32773
Location: Indoor: Heating Cooling
Orlando/Jetport, FL, US Indoor temperature (OF) 70 75
Elevation: 105 ft Design TD (OF) 28 18
Latitude: 28°N Relative humidity (%) 30 50
Outdoor: Heating Cooling Moisture difference (gr/lb) 0.8 45.8
Dry bulb (IF) 42 93 Infiltration:
Daily range (IF) - 16 ( M Method Simplified
Wet bulb (OF) - 76 Construction quality Semi -tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
ft Btu h/ft2- °F ft%T/Btuh BtuhM Btu Btu h/ft Btu
Walls
12C-Osw: Frm wall, stucco ext, r-13 cav ins, 1/2" gypsum board int n 337 0.091 13.0 2.52 849 2.85 959
fnsh, 2"x4" wood frm, 16" o.c. stud e 194 0.091 13.0 2.52 490 2.85 553
s 349 0.091 13.0 2.52 879 2.85 993
w 210 0.091 13.0 2.52 528 2.85 596
all 1089 0.091 13.0 2.52 2746 2.85 3101
13A-2ocs: Blk wall, stucco ext, r-2 ext bd ins, 8" thk, 1/2" gypsum n 252 0.201 0 5.57 1403 5.29 1334
board int fnsh e 55 0.201 0 5.57 308 5.29 293
s 323 0.201 0 5.57 1800 5.29 1712
w 199 0.201 0 5.57 1110 5.29 1055
all 830 0.201 0 5.57 4621 5.29 4394
Partitions
12C-Osw: Frm wall, r-13 cav ins, 1/2" gypsum board int fnsh, 2"x4" 332 0.091 13.0 2.52 837 1.45 482
wood frm, 16" o.c. stud
Windows
2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, n 12 0.540 0 15.0 179 14.1 169
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.31); 50% drapes, medium; 1
ft overhang (4 ft window ht, 1.17 ft sep.); 6.67 ft head ht
2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, n 15 0.540 0 15.0 228 14.1 215
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.31); 50% drapes, medium; 1 e 46 0.540 0 15.0 684 33.9 1549
ft overhang (5.08 ft window ht, 1.17 ft sep.); 6.67 ft head ht s 15 0.540 0 15.0 228 14.3 219
w 31 0.540 0 15.0 456 33.9 1033
all 107 0.540 0 15.0 1597 28.2 3015
2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, s 15 0.540 0 15.0 231 15.7 242
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.31); 50% drapes, medium; 1
ft overhang (5.3 ft window ht, 10.83 ft sep.); 6.67 ft head ht s 16 0.540 0 15.0 238 15.7 249
all 31 0.540 0 15.0 469 15.7 491
2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, w 33 0.540 0 15.0 489 14.1 460
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.31); 50% drapes, medium; 11
ft overhang (5.3 ft window ht, 0.5 ft sep.); 6.67 ft head ht
2018-Jan-13 11:02:55
WrlgfltSOft'° Right -Suite® Universal 2017 17.0.23 RSU23828 Page 1
ACCA...veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MJ8 House faces: E
2A-2omd: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, w 48 0.620 0 17.2 824 16.1 772
1/4" gap, 1/8" thk; NFRC rated (SHGC=0.25); 11 ft overhang (8 ft
window ht, 0.5 ft sep.); 6.67 ft head ht
Doors
11 DO: Door, wd sc type e 24 0.390 0 10.8 259 12.0 2B9
n 18 0.390 0 10.B 193 12.0 215
all 42 0.390 0 10.8 452 12.0 504
Ceilings
16B-30ad:Attic ceiling, asphalt shingles roof mat, r-30 ceiI ins, 1/2" 1301 0.032 30.0 0.89 1153 1.74 2263
gypsum board int fnsh
Floors
20P-11t: Flr floor, frm flr, 12" thkns, r-11 cav ins, gar ovr 397 0.078 11.0 2.16 857 1.12 444
22A-tpl: Bg floor, light dry soil, on grade depth 104 0.989 0 27.4 2835 0 0
2018-Jan-13 11:02:55
C. " f wrightsoft` Right -Suite® Universal 2017 17.0.23 RSU23828 Page 2
ZtAP...veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MJ8 House faces: E
Project Summary Job: Lot 1MensingtonReser...
WI'iQf1t$O Date: 7/25/2015
Entire House By: FJF
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW-DEL-AIR.COM
For: RYAN HOMES
3701 CRAWLEY DOWN LOOP, SANFORD, FL32773
Desi' n InformPrs .a anon.. r
Weather: Orlando/Jetport, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 IF Outside db 93 IF
Inside db 70 IF Inside db 75 IF
Design TD 28 IF Design TD 18 IF
Daily range M
Relative humidity 50 %
Moisture difference 46 gr/lb
Heating Summary
Structure 19731 Btuh
Ducts 3552 Btuh
Central vent (0 cfm) 0 Btuh
none)
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 23283 Btuh
Infiltration
Method
Construction quality
Fireplaces
Area (ft2
Volume ft3)
Air changes/hour
Equiv. AVF (cfm)
Simplified
Semi -tight
0
He tin Co olig
2154 21n54
18852 18852
0.28 0.15
88 47
Heating Equipment Summary
Make Goodman Mfg.
Trade GOODMAN; JANITROL; AMANA DISTI
Model GSZ140361 K
A H R I ref :8242629
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
Capacity balance point = 34 OF
Backup:
8.5 HSPF
32600 Btuh @ 47°F
26 OF
1160 cfm
0.050 cfm/Btuh
0.30 in H2O
Input = 0 kW, Output = 0 Btuh, 100 AFUE
Sensible Cooling Equipment Load Sizing
Structure 21939 Btuh
Ducts 6308 Btuh
Central vent (0 cfm) 0 Btuh
none)
Blower 0 Btuh
Use manufacturer's data y
Rate/swing multiplier 1.00
Equipment sensible load 28247 Btuh
Latent Cooling Equipment Load Sizing
Structure 2462 Btuh
Ducts 1512 Btuh
Central vent (0 cfm) 0 Btuh
none)
Equipment latent load 3973 Btuh
Equipment Total Load (Sen+Lat) 32220 Btuh
Req. total capacity at 0.75 SHR 3.1 ton
Cooling Equipment Summary
Make Goodman Mfg.
Trade GOODMAN; JANITROL; AMANA DIST]...
Cond GSZ140361 K
Coil ASPT471D14A
A H R I ref :8242629
Efficiency 12.5 EER, 15 SEER
Sensible cooling 26100 Btuh
Latent cooling 8700 Btuh
Total cooling 34800 Btuh
Actual air flow 1160 cfm
Air flow factor 0.041 cfm/Btuh
Static pressure 0.30 in H2O
Load sensible heat ratio 0.88
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
WriihtSOft" 2018-Jan-1311:02:55 9
Right -Suite® Universal 2017 17.0.23 RSU23828 Page 1 ACCk ..
veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MJ8 House faces: E
wrightsoft° Right-JO Worksheet
Entire House
DEL -AIR HEATING & AIR
CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM
Job: Lot137KensingtonReserveL...
Date: 7/25/2015
By: FJF
1 Room name Entire House great rm
2 Exposed wall 254.5 ft 62.0 ft
3 Room height 8.5 ft 9.3 it heat/cool
4 Room dimensions 30.0 x 16.0 it
5 Room area 2205.8 ft2 480.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number Btuh/ft2-'F) Btu ft2) or perimeter (it) Btuh) or perimeter (it) Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 Vf/ 12C-Osw 0.091 n 2.52 2.85 364 337 849 959 0 0 0 0
2A-2om 0.540 n 14.96 14.08 12 0 179 169 0 0 0 0
L
G
2A-2om 0.540 n , 14.96 14.08 15 0 228 215 0 0 0 0
W 13A-2ocs 0.201 n 5.57 5.29 252 252 1403 1334 149 149 831 791
11 12C-Osw 0,091 e 2.52 2.85 240 194 490 553 0 0 0 0
2A-2om 0.540 e 14.96 33.86 46 0 684 1549 0 0 0 0
W 13A-2ocs 0,201 e 5.57 5.29 79 55 308 293 0 0 0 0
L-D 11DO 0.390 e 10.80 12.03 24 24 259 289 0 0 0 0
12C-Osw 0.091 s 2.52 2:85 364 349 879 993 0 0 0 0
2A-2om: 0.540. s 14.96 14.34 15 13 228 219 0 0 0 0
13A-2ocs 0.201 s 5.57 5.29 355 323 1800 1712 149 118 657 625
2A-20m 0.540 s 14.96 15.65 15 0 231 242 15 0 231 242
2A-20m 0.540 s 14.96 15.65 16 0 238 249 16 0 238 249
12C-Osw 0.091 w 2:52 2.85 240 210 528 596 0 0 0 0
2A-2om 0.540 w 14.96 33.86 31 10 456 1033 0 0 0 0
V 13A-2ocs 0.201 w 5.57 5.29 280 199 1110 1055 280 199 1110 1055
G 2A-2om 0.540 w 14.96 14.08 33 33 489 460 33 33 489 460
G 2A-2omd 0.620 w 17.17 16.08 48 48 824 772 48 48 824 772
f 12C-Osw 0.091 2.52 1.45 350 332 837 482 0 0 0 0
11DO 0.390 n., 10.80, 12.03 18 18 193 215 0 0 0 0
C 16B-30ad 0.032 0.89 1.74 1301 1301 1153 2263 0 0 0 0
F 2OP-11t 0.078 2:16 1.12 397 397 857 444. 0 0 0 0
F 22A-tpl 0.989 27.40 0.00 905 104 2835 0 480 62 1699 0
6 c) AED excursion 789 872
Envelope loss/gain 17061 16885 6079 5066
12 a) Infiltration 2670 904 711 241
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 5 1150 4 920
Appliances/other 30DO 600
Subtotal (lines 6 to 13) 19731 21939 6790 6826
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 19731 21939 6790 6826
15 Duct loads 18 % 29 % 3552 6308 15 % 28 % 1012 1911
Total room load 23283 282471 7801 8738
Air required (cfm) 1160 1160 389 359
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoft'
2018-Jan-1311:02:55
9 Right -Suite@ Universal 2017 17.0.23 RSU23828 Page 1
veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MJ8 House faces: E
wrightsoft, Right-JO Worksheet
Entire House
DEL -AIR HEATING & AIR
CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM
Job: Lot137KensingtonReserveL...
Date: 7/25/2015
By: FJF
1 Room name pdr mud rm
2 Exposed wall 8.0 it 6.0 It
3 Room height 9.3 it heat/cool 9.3 it heat/cool
4 Room dimensions 4.5 x 8.0 ft 6.0 x 6.0 ft
5 Room area 36.0 ft2 36.0 ft2
Ty Construction LI-value Or HTM Area (ft2) Load Area (ft2) Load
number Btuh/ft2°F) Btuh/ft2) or perimeter (ft) Btuh) or perimeter (it) Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 V+/ 12C-0sw 0.091 n 2.52 2.85 0 0 0 0 0 0 0 0
2A-2om 0.540 n 14.96. 14.08 0 0 0 0 0 0 0 0IGG
2A-2om 0.540 n 14.96 14.08 0 0 0 0 0 0 0 0
W 13A-2ocs 0.201 n 5.57 5.29 0 0 0 0 56 56 312 297
11 VI/ 12C-Osw 0.091 e`- 2.52 2.85 0 0 0 0 0 0 0 0
I-G 2A-2om 0.540 e. 14.96 33.86 0 0 0 0. 0 0 0 0
VI/
T-D
13A-2ocs 0.201 e 5.57 5.29 0 0 0 0 0 0 0 0
11DO 0.390 e 10.80 12.03 0 0 0 0 0 0 0 0
V+/ 12C-0sw 0.091 s' 252 2.85 0 0 0 0 0 0 0 0
G 2A-2om ., 0.540 s_. 14.96 14.34 0 0 0 0, 0_ 0 0 0
13A-2ocs 0.201 s 5.57 5.29 75 75 416 395 0 0 0 0T_j 2A-2om 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
2A-2om 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
1/ 12C-0sw 0.091 w- 2.52 2.85 0 0 0 0 0 0 0 0
G 2A-2om 0.540 w_ 14.96 33.86 0 0 0 0 0 0 0 0
13A-2ocs 0.201 w 5.57 5.29 0 0 0 0 0 0 0 0
2A-2om 0.540 w 14.96 14.08 0 0 0 0 0 0 0 0
2A-2omd 0.620 w 17.17 16.08 0 0 0 0 0 0 0 0
R 12C-Osw 0.091 2.52 1.45 0 0 0 0 79 61 155 89
I-D 11DO 0.390 n 10.80 12.03 0 0 0 0 18 18 193 215
C 1613-30ad 0.032 0.89 1.74 0 0 0 0 0 0 0 0
F 20P-11t 0.078 2.16 1.12 0, 0 0 0 0 0 0 0
F 22A-tpl 0.989 27.40 0.00 36 8 219 0 36 6 164 0
6 c) AED excursion 29 42
Envelope loss/gain 635 367 824 559
12 a) Infiltration 92 31 69 23
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13) 727 398 893 582
Less external load 0 0 b 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 727 398 893 582
15 Duct loads 15 % 28 % 108 111 15 % 28% 133 163
Total room load 835 509 1026 745
Air required (cfm) 42 21 51 31
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoft• 2018-Jan-1311:02:55
A.
9 Right -Suite@ Universal 2017 17.0.23 RSU23828 Page 2
veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MJ8 House faces: E
rF wrightsoft° Right-JO Worksheet
Entire House
DEL -AIR HEATING & AIR
CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM
Job: Lot137KensingtonReservelL
Date: 7/25/2015
By: FJF
1 Room name kitchen mstr rm
2 Exposed wall 27.5 ft 30.5 ft
3 Room height 9.3 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 1.0 x 352.5 ft 1.0 x 251.5 ft
5 Room area 352.5 ft2 251.5 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number Btuh/ft2-OF) Btuh/ft2) or perimeter (ft) Btuh) or perimeter (ft) Btuh)
Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 VfJ 12C-Osw 0.091 n 2.52 2.85 0 0 0 0 0 0 0 0
2A-2om 0.540 n 14.96 14.08 0 0 0 0 0 0 0 0
L
G
2A-2om 0.540 0 14.96 14.08 0 0 0 0 0 0 0 0
W 13A-2ocs 0.201 n 5.57 5.29 47 47 260 247 0 0 0 0
11 L_G12C-Osw 0.091 e 2.52 2:85 0 0 0 0 0 0 0 0
2A-2om 0.540 e 14.96 33.86 0 0 0 0 0 0 0 0
y/ 13A-2ocs 0.201 e 5.57 5.29 79 55 308 293 0 0 0 0
I-D 11DO 0.390 e 10.80 12.03 24 24 259 289 0 0 0 0
V+/ 12C-Osw 0.091' s 2.52 2.85 0 0 0 0 136 136 343' 387
2A-2om 0.54o s 14.96 14.34 0 0 0 0 0 0 0. 0
v 13A-2ocs 0.201 s 5.57 5.29 131 131 728 692 0 0 0 0
I--C
C
2A-2om 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
2A-2om 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
V 12C-Osw 0.091 w 2.52 2.85 0 0 0 0 108 78 195 221
G 2A-2om 0.540 w 14.96 33.86 0 0 0 0 31 0 456 1033
13A-2ocs 0.201 w 5.57 5.29 0 0 0 0 0 0 0 0
2A-2om 0.540 w 14.96 14.08 0 0 0 D 0 0 0 0
2A-2omd 0.620 w 17.17 16.08 0 0 0 0 0 0 0 0
f- 12C-Osw 0.091 2.52 1.45 271 271 682 393 0 0 0 0
11 DO 0.390 n 10.80 12.03 0 0 0 0 0. 0 0 0
C 1613-30ad 0.032 0.89 1.74 0 0 0 0 252 252 223 437
F 20P-11t 0.078 2.16 1.12 0 0 0 0 0 0. 0 0
F 22A-tpl 0.989 27.40 0.00 353 28 753 D 0 0 0 0
6 c) AED excursion 216 294
Envelope loss/gain 2990 1697 1217 2372
12 a) Infiltration 315 107 300 101
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 1200 600
Subtotal (lines 6 to 13) 1 3306 3004 115171 3303
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3306 3004 1517 3303
15 Duct loads 15 % 28 % 493 841 23 % 29 % 342 974
Total room load 3798 3845 1859 4277
Air required (cfm) 189 158 93 176
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
writ htsoft- 2018-Jan-1311:02:55gP.
9 Right -Suite@ Universal 2017 17.0.23 RSU23828 Pa e 3
veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MJ8 House faces: E
wrightsoft, Right-J® Worksheet
Entire House
DEL -AIR HEATING & AIR
CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM
Job: Lot137KensingtonReserveL...
Date: 7/25/2015
By: FJF
1 Room name rm 3 wic rm 2
2 Exposed wall 12.0 ft 7.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 7.0 x 5.0 It 1.0 x 149.8 ft
5 Room area 35.0 ft2 149.8 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number Btuh/ftz°F) Btu ft2) or perimeter (ft) Btuh) or perimeter (ft) Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 V/ 12C-Osw 0.091 n 2.52 2.85 0 0 0 0 0 0 0 0
2A-20m 0.540 n 14.96 14.08 0 0 0 0 0 0 0 0
I
G
2A-2om 0.540 n 14.96 14.08 0 0 0 0 0 0 0 0
W 13A-2ocs 0.201 n 5.57 5.29 0 0 0 0 0 0 0 0
11 W 12C-Osw 0.091 a 2.52 2.85 56 56 141 159 36 21 52 59
I 2A-2om 0.540 e 14.96 33.86 0 0 0 0 15 0 228 516
L-D
13A-2ocs 0.201 e 5.57 5.29 0 0 0 0 0 0 0 0
11 DO 0.390 e 10.80 12.03 0 0 0 0 0 0 0 0
V+l 12C-Osw 0.091 s 2.52 2.85 40 40 101 114 20 20 50 57
t-G 2A-2om 0.540 s 14.96 14.34 0 0 0 0 0 0 0 0
13A-2ocs 0.201 s 5.57 5.29 0 0 0 0 0 0 0 0
2A-2om 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
GG' 2A-20m 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
t12C-Osw 0.091 w 2.52 2.85 0 0 0 0 0 0 0 0
1 2A-2om 0.540 w 14.96 33.86 0 0 0 0 0 0 0 0
0.201 w 5.57 5.29 0 0 0 0 0 0 0 0
2A-2om 0.540 w 14.96 14.08 0 0 0 0 0 0 0 0LJ13A-
2ocs
2A-2omd 0.620 w 17.17 16.08 0 0 0 0 0 0 0 0
12C-Osw 0.091 2.52 1.45 0 0 0 0 0 0 0 0
11 DO 0.390 n 10.80 12.03 0 0 0 0 0 0 0 0
C 168-30ad 0.032 0.89 1.74 35 35 31 61 150 150 133 260
F 2OP-11t 0.078 2.16 1.12 35 35 76 39 84 84 180 93
F 22A-tpl 0.989 27.40 0.00 0 0 0 0 0 0 0 0
6 c) AED excursion 28 75
Envelope loss/gain 349 346 644 1061
12 a) Infiltration 118 40 69 23
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13) 467 385 713 1084
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 467 385 713 1084
15 Duct loads 23 % 29 % 105 114 23 % 29 % 161 320
Total room load 572 499 873 1404
Air required (cfm) 28 20 44 58
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Wri htsoft- 2018-Jan-1311:02:55
t= 9 Right -Suite® Universal 2017 17.0.23 RSU23828 Page 4
veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MJ8 House faces: E
J& wrightsoft® Right-JO Worksheet
Entire House
DEL -AIR HEATING & AIR
CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM
Job: LotlMensingtonReserveL...
Date: 7/25/2015
By: FJF
1 Room name rm 3 bth 1
2 Exposed wall 25.0 it 5.5 it
3 Room height 8.0 it heat/cool 8.0 it heat/cool
4 Room dimensions 14.5 x 10.5 it 11.0 x 5.5 it
5 Room area 152.3 ft2 60.5 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number BtuWftz°F) Btuh/ft2) or perimeter (it) Btuh) or perimeter (it) Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 VI/ 12C-Osw 0.091 n 2.52 2.85 84 84 212 239 44 44 111 125
2A-2om 0.540 n 14.96 14.08 0 0 0 0 0 0 0 0
L
G
2A-2om 0.540 n 14.96 14.08 0 0 0 0 0 0 0 0
W 13A-2ocs 0.201 n 5.57 5.29 0 0 0 0 0 0 0 0
11 VGW 12C-Osw 0.091 e 2.52 2.85 116 86 216 243 0 0 0 0
2A-2om 0.540 e- 14.96 33.86 31 0 456 1033 0 0 0 0
W 13A-2ocs 0.201 a 5.57 5.29 0 0 0 0 0 0 0 0
I-D 11 DO 0.390 e 10.80 12.03 0 0 0 0 0 0 0 0
12C-Osw 0.091 s 2.52 2.85 0 0 0 0 0 0 0 0
2A-2om 0.540 s 14.96 14.34 0 0 0 0 0 0 0 0
t 13A-2ocs 0.201 s 5.57 5.29 0 0 D D 0 D 0 0
I-G 2A-2om 0.540 s 14.96 15.65 0 0 0 0 D 0 0 0
1------(GGG' 2A-2om 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
12C-Osw 0.091 w 2.52 2.85 0 0 0 0 0 0 0 0
2A-2om 0.540 w 14.96 33.86 0 0 0 0 0 0 0 0
13A-20cs 0.201 w 5.57 5.29 0 0 0 0 O f 0 0 0
0.540 w 14.96 14.08 0 0 0 0 0 0 0 0j2A-2om
2A-2omd 0.620 w 17.17 16.08 0 0 0 0 0 0 0 0
1--D12C-Osw 0.091 2.52 1.45 0 0 0 0 0 0 0 0
11 DO 0.390 n 10.80 12.03 0 0 0 0 0 0 0 0
C 168-30ad 0.032 0.89 1.74 152 152 135 265 61 61 54 105
F 20P-11t 0.078 2.16 1.12 152 152 329 170 61 61 131 68
F 22A-tpl 0.989 27.40 0.00 0 0 0 0 0 0 0 0
61 c) AED excursion 1 149 21
Envelope loss/gain 1347 2099 295 277
12 a) Infiltration 246 83 54 18
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13) 1593 2182 349 295
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1593 2182 349 295
15 Duct loads 23% 29% 359 643 23% 29%1 791 87
Total room load 1952 2826 428 382
Air required (cfm) 97 116 21 16
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoft- 2018-Jan-1311:02:55
P.
9 Right -Suite® Universal 2017 17.0.23 RSU23828 Page 5
veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MJ8 House faces: E
wrightsoft° Right-J® Worksheet
Entire House
DEL -AIR HEATING & AIR
CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM
Job: Lot 1 37Kensington Reservell-
Date: 7/25/2015
By: FJF
1 Room name laundry rm 4
2 Exposed wall 5.5 it 11.0 ft
3 Room height 8.0 it heat/cool 8.0 it heat/cool
4 Room dimensions 6.5 x 5.5 ft 1.0 x 132.3 ft
5 Room area 35.8 ft2 132.3 ft2
Ty Construction
number
U-value
Btuh/ft2°F)
Or HTM
Btu h ft2)
Area (ft2)
or perimeter (it)
Load
Btuh)
Area (ft2)
or perimeter (ft)
Load
Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 0.091 n 2.52 2.85 44 44 111 125 88 73 183 207
tj12C-0sw
2A-20m 0.540 n 14.96 14.08 0 0 0 0 0 0 0 0
2A-2om 0.540 n 14.96 14.08 0 0 0 0 15 0 228 215
W 13A-2ocs 0.201 n 5.57 5.29 0 0 0 0 0 0 0 0
11 12C-0sw 0.091 a 2.52 2.85 0 0 0 0 0 0 0 0
I-G 2A-2om 0.540 e: 14.96 33.86 0 0 0 0 0 0 0 0
V/ 13A-2ocs 0.201 e 5.57 5.29 0 0 0 0 0 0 0 0
I-0 11 DO 0.390 e 10.80 12.03 0 0 0 0 0 0 0 0
y/ 12C-0sw 0.091 s 2.52 2.85 0 0 0 0- 0 0 0 0
2A-2om 0.540 s 14.96 14.34 0 0 0 0. 0 0 0 0
13A-2ocs 0.201 s 5.57 5.29 0 0 0 0 0 0 0 0
2A-2om 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
2A-2om 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
12C-0sw 0.091 w 2.52 2.85 0 0 0 0 0 0 0 0
G 2A-2om 0.540 w 14.96 33.86 0 0 0 0 0 0 0 0
13A-2ocs 0.201 w 5.57 5.29 0 0 0 0 0 0 0 0
2A-2om 0.540 w 14.96 14.08 0 0 0 0 0 0 0 0
2A-2omd 0.620 w 17.17 16.08 0 0 0 0 0 0 0 0
12C-Osw 0.091 2.52 1.45 0 0 0 0 0 0 0 0
11 DO 0.390 h 10.80 12.03 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 0.89 1.74 36 36 32 62 132 132 117 230
F _ . 20P-llt, 0.078 2.16, 1.12 18 18 38 20 0 0 0 0
F 22A-tpl 0.989 27.40 0.00 0 0 0 0 0 0 0 0
6 c) AED excursion 55 46
Envelope loss/gain 180 152 529 606
12 a) Infiltration 54 18 108 37
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 600 0
Subtotal (lines 6 to 13) 234 770 637 642
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 234 770 637 642
15 Duct loads 23% 29% 53 227 23% 29%1 144 189
Total room load 287 997 780 832
Air required (cfm) 14 41 39 34
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft'
2018-Jan-13 11:ge 6
P.
Right-SuiteC Universal 2017 17.0.23 RSU23828 Page
veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Cale = MJ8 House faces: E
wrightsoft® Right-JO Worksheet
Entire House
DEL -AIR HEATING & AIR
CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM
Job: Lot137KensingtonReservelL
Date: 7/25/2015
By: FJF
1 Room name mstr bth mstr wic
2 Exposed wall 22.0 it 7.5 ft
3 Room height 8.0 it heat/cool 8.0 it heat/cool
4 Room dimensions 1.0 x 111.0 ft 7.5 x 5.0 it
5 Room area 111.0 ft2 37.5 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number Btuh/ftZ°F) Btuh/ft2) or perimeter (it) Btuh) or perimeter (ft) Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 0.091 n 2.52 2.85 1o4 92 232 262 0 0 0 0T12C-Osw
2A-2om 0:540 n 14.96 14.08 12 0 179 169 0 0 0 0
2A-2om 0.540 n 14.96 14.'08 0 0 0 0 0 0_ 0 0
W 13A-2ocs 0.201 n 5.57 5.29 0 0 0 0 0 0 0 0
11 VLG12C-Osw 0.091 e 2:52 2.85 0 0 0 0 0 0 0 0
2A-2om 0.540 e. 14.96 33.86 0 0 0_ 0 0 0 0 0
t-D
13A-2ocs 0.201 e 5.57 5.29 0 0 0 0 0 0 0 0
11 DO 0.390 e 10.80 12.03 0 0 0 0 0 0 0 0
Vf/ 12C-Osw 0.091 s 2.52 2.85 0 0 0 D 0 0 0 0
I--G 2A-2om 0.540 s-, 14.96. 14.34 0 0, 0 0 0 0 0 0
13A-2ocs 0.201 s 5.57 5.29 0 0 0 D D 0 0 0
2A-2om 0.540 s 14.96 15.65 0 D 0 0 0 0 0 0
CGC: 2A-2om 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
y/ 12C-Osw 0.091 w 2.52 2.85 72 72 181 205 60 60 151 171
I--G 2A-2om 0.540 w 14.96. 33.86 0 0 0 0 0 0 0 0
0.2D1 w 5.57 5.29 0 0 0 0 0 0 0 0
tj13A-2ocs
2A-2om 0.540 w 14.96 14.08 0 0 0 0 0 0 0 0
2A-2omd 0.620 w 17.17 16.08 0 0 0 0 0 0 0 0
F1 12C-Osw 0.091 2.52 1.45 0 0 0 0 0 0 0 0
11 DO 0.390 n 1080. 12.03 0 0 0 0_ 0 0 0 0
C 168-30ad 0.032 0.89 1.74 111 111 98 193 38 38 33 65
F 2OP-11t 0.078 2.16 1.12 0 0 0 0 0 0 0 0
F 22A-tpl 0.989 27.40 0.00 0 0 0 0 0 0 0 0
6 c) AED excursion 61 18
Envelope loss/gain 691 768 184 218
12 a) Infiltration 216 73 74 25
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13) 907 841 258 243
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 907 841 258 243
15 Duct loads 23 % 29% 205 248 23% 29 % 58 72
Total room load 1 11121 1090 316 315
Air required (cfm) 55 45 16 13
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Fk- wrightsoft- 2018-Jan-13 11:02:55
Right -Suite® Universal 2017 17.0.23 RSU23828 Page 7
veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MJ8 House faces: E
wrightsoft, Right-M Worksheet
Entire House
DEL -AIR HEATING & AIR
CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM
Job: Lot 137KensingtonReserveL...
Date: 7/25/2015
By: FJF
1 Room name mstr wic int mstr we
2 Exposed wall 0 ft 0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 5.5 x 4.5 ft 5.5 x 4.0 ft
5 Room area 24.8 ft2 22.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number Btuh/ft2-'F) Btuh/ft2) or perimeter (ft) Btuh) or perimeter (ft) Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 y/ 12C-Osw 0.091 n' 2.52 2.85 0 0 0 0 0 0 0 0
2A-2om 0.540 n 14.96 14.08 0 0 0 0 0 0 0 0IGG
2A-2om 0.540. n 14.96 14.08 0 0 0 0 0 0 0 0
W 13A-2ocs 0.201 n 5.57 5.29 0 0 0 0 0 0 0 0
11 V?/' 12C-Osw 0.091 e 2.52 2.85 0 0 0 0 0 0 0 0
1 2A-2om. 0.540 e 14.96: 33.86 0 0 0 0 0 0 0 0
13A-2ocs 0.201 e 5.57 5.29 0 0 0 0 0 0 0 0Y__D 11 DO 0.390 e 10.80 12.03 0 0 0 0 0 0 0 0
yJ 12C-Osw 0.091 s 2.52 2.85 0 0 0 0 0 0 0 0
1LZ 2A-2om 0.540 s 14.96. 14.34 0 0 0 0 0 0_ 0 0
V)/ 13A-20cs 0.201 s 5.57 5.29 0 0 0 0 0 0 0 0
2A-2om 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
I
G
2A-2om 0.540 s 14.96 15.65 0 0 0 0 0 0 0 0
VI/ 12C-Osw 0.091 w 2.52 2.85 0 0 0 0 0 0 0 0
LG 2A72om 0.540 w 14.96 33.86 0 0 0 0 0, 0, 0 0
V 13A-2ocs 0.201 w 5.57 5.29 0 0 0 0 0 0 0 0
2A-2om 0.540 w 14.96 14.08 0 0 0 0 0 0 0 0
2A-2omd 0.620 w 17.17 16.08 0 0 0 0 0 0 0 0
Fi- 12C-Osw 0.091 2.52 1.45 0 0 0 0 0 0 0 0
ID 11 DO 0.390 n 10.80 12.03 0 0 0 0 0 0 0 0
C 11613-30ad 0.032 0.89 1.74 25 25 22 43 22 22 20 38
F 201P-11t 0.078 2.16 1.12 0 0 0 0 0 0 0 0
F 22A-tpl 0.989 27.40 0.00 0 0 0 0 0 0 0 0
6 c) AED excursion 3 3
Envelope loss/gain 22 40 20 36
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13) 22 40 20 36
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 22 40 20 36
15 Duct loads 23 % 29 % 5 12 23 % 299.1 4 11
Total room load 27 52 24 46
Air required (cfm) 1 2 1 2
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Wri ht30ft"
2018-Jan-1311:02:55
9 Right-SuiteO Universal 2017 17.0.23 RSU23828 Page 8
veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Cale = MJ8 House faces: E
wrightsoft, Right-JO Worksheet
Entire House
DEL -AIR HEATING & AIR
CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM
Job: Lot137KensingtonReserveL...
Date: 7/25/2015
By: FJF
1 Room name loft
2 Exposed wall 25.0 ft
3 Room height 8.0 ft heat/cool
4 Room dimensions 1.0 x 289.0 ft
5 Room area 289.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area Load
number Btuh/ftz°F) BtuhJft2) or perimeter (ft) Btuh) or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 VI/ 12C-Osw 0.091 n 2.52 2.85 0 0 0 0
2A-20m 0.540 n 14.96 14.08 0 0 0 0`
2A-20m 0.540 n 14.96 14.08 0 0 0 0
W 13A-2ocs 0.201 n 5.57 5.29 0 0 0 0
11 V l 12C-Osw 0.091 e.' 2.52 2.85 32 32 81 91
L-( 2A-2om 0.540 e , 14.96 33.86 0 0 0 0
V/ 13A-2ocs 0.201 e 5.57 5.29 0 0 0 0
11DO 0.390 e 10.80 12.03 0 0 0 0Z
yl 12C-Osw 0.091 s 2.52 2.85 168 153 385 435
a 2A-2om 0.540 s 14.96 14.34 15 13 228 219
13A-2ocs 0.201 s 5.57 5.29 0 0 0 0
2A-20m 0.540 s 14.96 15.65 0 0 0 0
2A-2om 0.540 s 14.96 15.65 0 0 0 0
V/ 12C-Osw 0.091' w 2.52 2.85 0 0 0 0
t-G 2A-2om 0.540 w 14.96 33.86 D 0 0 0
y/ 13A-2ocs 0.201 w 5.57 5.29 0 0 0 0
2A-2om 0.540 w 14.96 14.08 0 0 0 0
2A-2omd 0.620 w 17.17 16.08 0 0 0 0
R 12C-Osw 0.091 2.52 1.45 0 0 0 0
I-D 11 DO 0.390 n 10.80 12.03 0 0 0 0
C 1613-30ad 0.032 0.89 1.74 289 289 256 503
F 2OP-11t 0.078 2.16 1.12 48 48 104 54
F 22A-tpl 0.989 27.40 0.00 0 0 0 0
6 c) AED excursion 79
Envelope loss/gain 1054 1222
12 a) Infiltration 246 83
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal (lines 6 to 13) 1299 1305
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 1299 1305
15 Duct loads 23 % 29 % 293 385
Total room load 1592 1690
Air required (cfm) 79 69
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsOft- 2018-Jan-1311:02:55
9 Right -Suite@ Universal 2017 17.0.23 RSU23828 Page 9
veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Cale = MJ8 House faces: E
g
Duct System Summary Job: Lot137KensingtonReser...
Wrightso'fte Date: 7/25/2015
Entire House By: FJF
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM
For: RYAN HOMES
3701 CRAWLEY DOWN LOOP, SAN FORD, FL32773
Heating Cooling
External static pressure 0.30 in H2O 0.30 in H2O
Pressure losses 0.06 in H2O 0.06 in H2O
Available static pressure 0.24 in H2O 0.24 in H2O
Supply / return available pressure 0.120 / 0.120 in H2O 0.120 / 0.120 in H2O
Lowest friction rate 0.197 in/100ft 0.197 in/100ft
Actual air flow 1160 cfm 1160 cfm
Total effective length (TEL) 122 ft
Name
Design
Btuh)
Htg
cfm)
Clg
cfm)
Design
FIR
Diam
in)
H x W
in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft) Trunk
loth 1 h 428 21 16 0.237 4.0 Ox 0 VIFx 16.1 85.0 SO
great rm h 3901 194 179 0.203 8.0 Ox 0 VIFx 23.2 95.0 st2
great rm-A h 3901 194 179 0.212 8.0 Ox 0 VIFx 18.0 95.0 st2
kitchen h 3798 189 158 0.212 8.0 Ox 0 VIFx 18.0 95.0 st2
laundry c 997 14 41 0.235 4.0 Ox 0 VIFx 16.9 85.0 st1
loft h 1592 79 69 0.295 5.0 Ox 0 VIFx 11.3 70.0
mstr bth h 1112 55 45 0.295 5.0 Ox 0 VIFx 11.3 70.0
mstr rm c 4277 93 176 0.304 8.0 Ox 0 VIFx 9.1 70.0
mstr we c 46 1 2 0.304 4.0 Ox 0 VIFx 8.9 70.0
mstr wic h 316 16 13 0.294 4.0 Ox 0 VIFx 11.6 70.0
mstr wic int c 52 1 2 0.326 4.0 Ox 0 VIFx 3.5 70.0
mud rm h 1026 51 31 0.206 4.0 Ox 0 VIFx 21.3 95.0 st2
pdr h 835 42 21 0.197 4.0 Ox 0 VIFx 27.1 95.0 st2
rm 2 c 1404 44 58 0.232 6.0 Ox 0 VIFx 18.4 85.0 st1
rm 3 c 2826 97 116 0.227 6.0 Ox 0 VIFx 20.8 85.0 st1
rm 3 wic h 572 28 20 0.209 4.0 Ox 0 VIFx 29.8 85.0 st1
rm 4 h 780 39 34 0.300 6.0 Ox 0 VIFx 10.1 70.0
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type cfm) cfm) FR fpm) in) in) Material Trunk
st2 Peak AVF 671 568 0.197 627 14.0 0 x 0 VinlFlx
SO Peak AVF 205 251 0.209 568 9.0 0 x 0 VinlAx
2018-Jan-13 11:02:56
ter WrlghtSOW Right -Suite@ Universal 2017 17.0.23 RSU23828 Page 1
m...veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MJ8 House faces: E
Name
Grille
Size (in)
Htg
cfm)
Clg
cfm)
TEL
ft)
Design
FR
Veloc
fpm)
Diam
in)
H x W
in)
Stud/Joist
Opening (in)
Duct
Matl Trunk
rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx
2018-Jan-13 11:02:56
Act- wrightSOW Right -Suite@) Universal 2017 17.0.23 RSU23828 Page 2
M...veLargoAGRE\Lot125KensingtonReserveLargoAGR.rup Calc = MA House faces: E
I
FORM R405-2017
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the
residential Simulated Performance Method shall include:
This checklist
A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, e-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst -case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report (one page) and an input summary checklist that can
be used for field verification (usually four pages/may be greater).
Energy Performance Level (EPL) Display Card (one page)
HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
Mandatory Requirements (five pages)
Required prior to CO for the Performance Method:
Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 -
one page)
A completed Envelope Leakage Test Report (usually one page)
If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report (usually one page)
EnergyGauge@ - USRCSB v6.0
1/13/2018 11:19:52 AM Page 1 of 1
r-----------------r
II I
II I
TANAI
I I Y-4• Cie. I.
II 1
II I
it I
II I
II
l7)!}EH 1 I •p 1
GREAT ROOM
9W an,
16'x12'
1 0
k14x8
lwcd 14x lw d
8'
PAN
3' bath duct - >Q160
to roof cap 14x8 lwcd 4'
w/fan AY ;;iNutone696RNB
O47M -____--
Transfer ducts/grilles sized In
compliance with Florida Residential
Building Code - M1602.4 Balanced
Return Air, exceptions 1-3, Builder
must provide unrestricted I Inch
undercut on doors to habitable
rooms,
2 CAR GIL— N— ARAGB
Y-Y Cl.h
I
Y
I
1610 x 70 owo
low
42X42 A/C SLAB
BY BLDR MIN
2' FROM WALL
A/C
A
Builder will need to
provide a/c duct chase
m ee ewe r-
8154 lwcd
4' n 45
t
s x`0K
loath
14' to roof cap
ag
an
Nutone 696RNI
1418 lwcd
17
All.
IV, 11 ,
0- i35
06 '
y ' I• I ' '2Qx6 wait ragI
ss
lOx6 lwcd
I'4 4d
20x6 wal /rao
ago'Laa
20
8x4 lwco
3.0 TON W/8KW P240V 1PH
1843 plen
platform by
bldr
scale -1/8'=1'0'
Must have a mIn1mum clearance of 4 Inches around the air handler per the State Energy code, Alt duct has an r=6 Insulation value,
L 8x4 lwcd E
20x6 wall rag
115
c6 lwcd roan
ear ee78'1P
4' dryer duct
to roof cap
w/dryer vent box
3' bath duct
to roof cap
w/fan
Nutone 696RNB
Rating
LIJ
Ld
LLJ
z
Ld 0
0 L-D O
o
z
z o) V) Lr-)
Q L Ln z CLJ LL
d 1j W
r-,LL_
z
o r
V m
w
o z o
z
Ja
1
ml-a
o =) Q Q:
mCL-icno0
j4.s j :-7-, V3;D I tl 1,S i o ,J
PSG pWV/
Advantage Plumbing, Inc
Signature
it
r3
h
b
o
RECORD COPY
3
0iLortic
SANFoRD
Al
VTA."
RECORD COPY
DESCRIPTION AS FURNISHED: Lot 125, KENSINGTON ,RESERVE, as recorded in Plat Book 81, Pages 86
through 92, Public Records of Seminole County, Florida.
PLOT PLAN FOR / CERTIFIED TO: Ryan Homes/NVR 'Inc.
TRACT J
POND-D
N 00*19,09" W
50.00'
I
31.80'
I
41.80'
LOT 125
I
a { J ( A\C o EXTENDED LANAI
5.00' 30.0' 15.00'
LOT 126 /
I
Lh
U1 A
O
M PROPOSED MODEL
LARGO VS1 - A
N GARAGE RIGHT y
m
5.00, 8.7, ENTRY
v o
d
Y 21.3" 15.00' J
3 16' DRIVE
I
25,20' 25.20'
10" UTIL.—
ESMT.
5' CONC WALK
CURB
N 00019'09" W
50.00'
C%
01
l-Ott
Ok to construct single family home
with setbacks and impervious area
shown on plan. 3(0.'7'/o ,y,1p•
1av'Oo vs1-A, CR
LOT 124
y P.C. LOT
LOT 121
r----- - - - - -o
247.36'
CRA TYIEY 1D0 iff I OOP
50' WIDE PRIVATE R/W)
PROPOSED = FINSHED SPOT GRADE ELEVATIONS PLOT PLAN ONLY NOT A SURVEY dUlLulr, [Il7Al KJ: AJ YUr<NIJNtU
PER DRAINAGE PLANS FR NT = 25'
PLOT PLAN AREA CALCULATIONS REAR = 20'
PROPOSED DRAINAGE FLOW GFO IMPERVIOUS COVERAGE = 2,113t SQUARE FEET OR 36.71- SIDE = 5' FOR 40' LOTS
LOT GRADING TYPE B Q0 LOT CONTAINS 5, 750f SQUARE FEET SIDE = 7.5' FOR 60' LOTS
PROPOSED FINISH FLOOR PER PANS = 31.0' LIVING AREA CONTAINS 1,353t SQUARE FEET SIDE = 10' FOR 75' LOTS
Q CONC/LANAI/PORCH CONTAINS 760f SQUARE FEET SIDE STREET = 25'
CRUASEYVH KER—S'COTT c ASAS'OC. , INC. — LAND S'UR V rORS ,
LEGEND - LEGEND -
P = PLAT P.D.L. • POINT ON LINE
5400 E. COLONIAL OR, ORLANDO, FL. 32807 (407)-277-3232 FAX (407)-658-1436
F = FIELD TYP. a TYPICAL NOTES:
I.P. IRON PIPE PR.C. POINT OF REVERSE CURVATURE
I.R. = IRON ROD PZ'CRAD. • POINT OF COMPOUND CURVATURE 1. THE UNDERSIGNED DOES HEREBY CERTIFY THAT THIS SURVEY MEETS THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF
C.M. MONUMENT = RADIAL PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER 5J-17 FLORIDA ADMINISTRATIVE CODE PURSUANT TO SECTION 472.027, FLORIDA STATUES
1/2, I.R.
TE
N.R. SET I.R. 1/" I=/pLB 4596 N.R. NON -RADIAL 2. UNLESS EMBOSSED WITH SURVEYOR'S SIGNATURE AND ORIGINAL RAISED SEAL, THIS SURVEY MAP OP. COME ARE NOT VALID.
REC. RECOVERED VP. = WITNESS POINT 3. THIS SURVEY WAS PREPARED FROM TITLE INFORMATION FURNISHED TO THE SURVEYOR. THERE MAY BE OTH R RESTRICTIONS
P.O.B. POINT OF BEGINNING CALC. =CALCULATED OR EASEMENTS THAT AFFECT THIS PROPERTY.
PA.C. PONT OF COMMENCEMENT PR.K = PERMANENT REFMONUMENT 4. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED UNLESS OTHERWISE SHOWN. I. INISHED FLOORERENCE ION CENTERLINEN&D NAIL 6 DISK B.S.L. BUILDING SETBACKLINE 5, THIS SURVEY IS PREPARED FOR THE SOLE BENEFIT OF THOSE CERTIFIED TO AND SHOULD NOT BE RELIED UPON BY ANY OTHER ENTITY. R/W
RIGHT-OF-WAY B.M = BENCHMARK 6. DIMENSIONS SHOWN FOR THE LOCATION OF IMPROVEMENTS HEREON SHOULD NOT BE USED TO RECONSTRUCT BOUNDARY LINES. ESMT. EASEMENT
B.B. • -BASE BEARING 7 BEARINGS, ARE BASED ASSUMED DATUM AND ON THE LINE SHOWN AS BASE BEARING (B.B.) - DRAIN. - DRAINAGE
UTIL. = UTILITY
B. ELEVATIONS, IF SHOWN, ARE BASED ON NATIONAL CEODERC VERTICAL DATUM OF 1929, UNLESS OTHERWISE NOTED. CL.FC. =
CHAIN LINK FENCE 9. CERTIFICATE OF AUTHORIZATION No. 4596. WDIFC. • WOOD
FENCE CID CONCRETE
BLOCK SCALE H- I" 20' -1 DRAWN BY: + P.C. POINT OF CURVATURE P.T.
PONT OF TANGENCY DESC. DESCRIPTION
CERTIFIED BY: DATE , ORDER No. L = ARCIUS
LENGTH PLOTPLAN 12-05-2017 5378- 17 D = DELTA
PLOT PLAN 12-22-2017 5819-17 C CHORD
C.B.
CHORD BEARING NORTH THIS
BUILDING/
PROPERTY DOES NOT LIE WITHIN-,,,r111,,,-'''.. . - ' L.J.-._._...._ THE ESTABLISHED
100 YEAR FLOOD PLANE AS PER "FIRM" tI TCF X. CR MEYER, R.L.S. 4714 J ES
W. SCOTT, R.L.S # 4801 ZONE "X"
MAP j 12117C0090F (09-28-07)
RECORD COPY
Permit #
CW of Sanford
Building and Fire Prevention
Product Approval Specification Forms
91
Project Location Address
gUILOiy
SA/VpORD
As required by Florida Statute 553.842 and Florida AdministratiTeCode 9N-3, please provide the information
and product approval number(s) on the building components listed below if they are to be utilized
on the construction project for which you are applying for a building permit. We recommend that you
contact your local product supplier should you not know the product approval number for any of the applicable
listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance
with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval
can be obtained at www.floridabuilding.org. The
following information must be available on the jobsite for inspections: 1.
This entire product approval form 2.
A copy of the manufacturer's installation details and requirements for each product. Category/
Subcategory Manufacturer Product Description
Florida
Approval # include
decimal 1.
Exterior Doors Swinging
Therma Tru Smooth Star 15000.2 Sliding
Ply Gem 4780 SGD 14634.2 - R1 Sectional
Wayne Dalton 9100 - #0600 / #0607 9174.11 8174.20 - R11 Roll
Up Automatic
Other
2.
Windows Single
Hung Ply Gem 1500 16103 - Horizontal
Slider Casement
Double
Hung Fixed
Awning
Pass
Through Projected
Mullions
Ply Gem 1500 16118 _ Wind
Breaker Dual
Action Other
Time
2014 1
Category/Subcategory Manufacturer Product
Description
Florida Approval #
Including decimal
3. Panel Walls
Siding
Soffits Aluminum Coils Inc. Aluminum l 12194- R5
Storefronts
Curtain Walls
Wall Louver
Glass block
Membrane
Greenhouse
E.P.S Composite
Panels
Other
4. Roofing Products
Asphalt Shingles CertainTeed Corp. CertainTeed Asphalt Roofing Shingles 5444 - R11
Underla meets InterWrap Inc. Rhino Roof Underlayment 151216 - R2
Roofing Fasteners
Nonstructural
Metal Roofing
Wood Shakes and
Shingles
Roofing tiles
Roofing
Insulation
Waterproofing
Built up roofing
System
Modified Bitumen
Single Ply Roof
Systems
Roofing slate
Cements/
Adhesives /
Coating
Liquid Applied
Roofing Systems
Roof Tile
adhesive
Spray Applied
Polyurethane
Roofing
E.P.S. Roof
Panels
Roof Vents Millennium Metals Inc. MMI-213 Off Ridge Vent 16568.2 - R1
Other
June 2014
Category/Subcategory ; Manufacturer Product Florida'Approvat # Description (
include. decimal) . 5.
Shutters Accordion
Bahama
Colonial
Roll
up Equipment
Other
6.
Skylights Skylights
Other
7.
Structural Components
Wood
Connectors / Anchors
Truss
Plates Engineered
Lumber Railing
Coolers/
Freezers Concrete
Admixtures Precast
Lintels Lott's Concrete Products Lintel 17867 Insulation
Forms Plastics
Deck
I Roof Wall
Prefab
Sheds Other
8.
New Exterior Envelope
Products Applicant'
s Signatu, c; _ Applicant'
s Name Please
Print) June
2014 J
Tracy
McDonald 3