Loading...
HomeMy WebLinkAbout2030 Jefferson Ave 12-133; ADDITION1 qPERMITADDRESvV Lfl(I O Al 4LWLv CONTRACT ADDRESS PHONE NUMBER PROPERTY OWNER VV ADDRESS PHONE NUMBER ELECTRICAL CONTRACTOR MECHANICAL CONTRACTO PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE SUBDIVISION PERMIT # DATE PERMIT DESCRIPTION Gz PERMIT VALUATION a,1 E-b 2 SQUARE FOOTAGE i FN3_1r-_-dCEIVED CITY OF SANFORD OCI, 2 0 2011 401 (0/ /Y. 1B U - ILDING.& FIRE 0ktVtNti6N PERMIT APPLICATION 1BY: I I . , 0, Application No: Documeited Construction Value: 7JobAddress: 3o oxi Historic District: Yes 0 Noj3- V_ Parcel ID:Zoning' Description of Work: ow Plan Review Contact Person. tle.: 2E-mail: Phone:o. Fax: E Property Owner Information ame'. Phone: k7,- treet: 0 r Resident of property? 1 1 4 Ity, State Zip: Contractor Information Name Street: City, State Zip: Name: Street: City, St, Zip: Y 3Y, 2yiSv ?, d-O Bonding Company: Address: 3uilding Permit I quare Footage: do. of Dwelling Units: lectrical E3 few Service— No. -of AMPS: Arch itecVEngineer Info Phone: Fax: State License No.: Phone: Fax: E-mail: aye Lender: Address: PERMIT INFORMATION Construction Type: Flood Zone: No. of Stories: Plumbing 13 New Construction - No. of Fixtures: lechanical 13 (Duct layout required for new systems) Fire Sprinkler/Alarm 0 No. of heads: Application 'is hereby made to obtain a permit to do the work and installations as indicated. I certify that i work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee b sed on past permit activity levels. Should calculated charges exceed the documented construction vl6khen the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Print Owner/Agent's Name 40 // OfFloriftBBIE BLANTON D Notary Public . State of Florida My Comm. Expires Feb 25, 2011 Commission N EE 60182 Bonded ThmLgh National Notary Assn. Owner/Agent is Personally Known to Me or Produced ID Type of ID APPROVALS: ZONING: 1 11-10,11 UTILITIES: ENGINEERING: `(mil 8-/t FIRE: Signature of Contractor/Agent Date Print Contractor/Agent's Name Signature of Notary -State of Florida Date Contractor/Agent is Personally Known to Me or Produced ID Type of ID WASTE WATER: I ILBUILDING: JZ — COMMENTS: OVc w i2t. 11 c.I t E ,ba, i,, t,,tat o c1o c,rct e.tc>l Rev 11.08 STATEMENT/AFFIDAVITOWNERBUILDER C Altamonte Springs, Casselberry, Lake Mary, Longwood, Oviedo, Sanford, Seminole County, Winter Springs Florida Statutes are quoted here in part for your information to indicate the authority for exemptions for homeowners from qualifying as contractors and to express any applicable restrictions and responsibilities. OWNERS MUST PERSONALLY APPEAR AT THE BUILDING DIVISION TO SIGN THIS DOCUMENT BY SITING THIS STATEMENT, I ATTEST THAT: (Initial to the left of each statement) I understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an exemption from the law. The exemption specifies that 1, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. 1 I understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. I understand that, as an owner -builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that a contractor is required by law to be licensed in Florida and to list his or her license numbers on all permit and contracts. I understand that I may build or improve a one -family or two-family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or residence must be for my own use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within to1 year after the construction is complete, the law will presume that I built or substantially improved it r sale or lease, which violates this exemption. f understand that, as the owner -builder, I must provide direct, onsite supervision of the construction. r .. I understand that I may not hire an unlicensed individual person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom. I employ have the licenses required by law and by city ordinance. TI understand that it is a frequent practice of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously implies that the property owner is providing his or her own labor jand materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner - builder and am aware of the limits of my insurance coverage for injuries to workers on my property. I understand that I may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on my building who Is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers' compensation for the employee. I understand that my failure to follow these laws may subject me to serious financial risk. Rev. 9.14.2009 1 60 rr I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern owner -builders as well as employers. I also understand that the construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. I,am of aware of construction practices and I have access to the Florida Building Codes. I understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, the Florida Department of Financial r Services, and the Florida Department of Revenue. I also understand that I may contact the Florida struction Industry Licensing Board at 1-850-487-1395 or at www.myflorida.com/dbpr/pro/cilb/ for Yrmore information about licensed contractors. f I am aware of, and consent to, an owner -builder building permit applied for in my name and understand that I am the party legally and financially responsible for the proposed construction activity at the address listed below. I agree to notify the building department immediately of any additions, deletions, or changes to any of the formation that I have provided on this disclosure or in the permit application package. Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Construction Industry Licensing Board, the Department of Business and Professional Regulation and the building department may be unable to assist you with any financial loss that you sustain as a result of a complaint. Your only remedy against an unlicensed contractor may be in r civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is property licensed and the status of the contractor's workers' compensation coverage. P`bperty do hereby state that I am qualified and capable. of performing the requested construction involved with the permit application filed and agree to the of Identificati Must be Photo ID) Date A violation of this exemption is a misdemeanor of the first degree punishable by a term of imprisonment not exceeding 1 year and a $1,000.00 fine in addition to any civil penalties. In addition, the local permitting jurisdiction shall withhold final approval, revoke the permit, or pursue any action or remedy for unlicensed activity against the owner and any person performing work that requires licensure under the permit issued. Rev. 9.14.2009 PERMIT # a - 3 3 PROJECT ADDRESS L CONTRACTOR REVISION DATE PHONE # 'fo (.g f 9 - % FAX # CONTACT PERSON DESCRIPTION OF REVISION UTILITY DEPT FIRE PREVENTION PLANNING BUILDING 11.2a orCtditi- on a NNo WaI,,,,,.hsmu A Owner: Eckhard Wachsmuth 2030 Jefferson Avenue Sandford, Florida 32772 Phone- (407)619-4764 Engineer: pr 321-863-3223 ES,LL ' NA I NIS. FLvF E DA 32754 IM 0 ` rs velleonenue0 Sandford FlI 32772 3 i Sheet List Sheet Number Sheet Name G-1 General Notes A-1 Floor Plan A-2 Front Elevation & Section A-3 Side & Rear Elevations S-1 Structural Plan S-2 R f ramin an S-3 Window &Door Details 72 Door Schedule J Floor Plan 1/4" = 1'-0" 22' - 0" Door Mark Count Family and Type Width Height Design Pressure p (PSO Positive Pressure Negative Pressure Zone 4 Zone 5 D1 1 Single -Flush: 36" x 80" T - 0" 6' - 8" 18.9 20.6 24.6 D2 1 Double -Glass 1: 60" x 80" 5'- 0" 6' - 8" 18.4 20.1 23.6 D3 1 Single -Flush: 32" x 80" 2' - 8" 6' - 8" 19.2 20.9 25.2 Window Schedule Window Mark Count Family and Type Rough Opening Design Pressure p (Pso Width Height Positive Pressure Negative Pressure Zone 4 Zone 5 W1 4 Single Hung Fin: 3232 3' - 1" 3' - 2" 19.9 21.6 26.7 Keynote Legend 02 41 OO.C22 WALL TO BE REMOVED 04 22 OO.W8 8" CMU WALL W/ (1) #5 IN FILLED CELL @ 6'-0" O.C. MAX (24" MIM LAP) Er.) smN.SK:I:E:. 32.1-81,3.,3223 r PE 47515 j Seal No. Description Date 3 Added Window & Door Repair Details 1/23/11 Addition for Wachsmuth Residence 2030 Jefferson Avenue Sandford, Florida 32772 Floor Plan Project number 11-0422 Date 8/20/11 Drawn by J. Kelley Checked by E. Shinkskie A-1 Scale 1/4" = 1'-0" b.C" ALL FLANGE VNjS) 8.mor n, ALL HEIGHTS ALL FLANGE UNITS) AT MIDPOINT OF ADJACENT ANCHORS FOR HEIGHTS OVER 72" HIGH ALL FLANGE UNITS) C.L. OF UNIT ENTER OF JAMB ALL HEIGHTS ALL FLANGE UNITS) AT MIDPOINT OF ADJACENT ANCHORS FOR HEIGHTS OVER 77' HIGH ALL FLANGE UNITS) i I 8,0W u ALL HEIGHTS TALL FLANGE UNITS) CENTER OF UNIT r1 FLANGE UNITS OVER 48" W1DE All FLANGE'IJNITS) WINDOW ELEVATION VIEWED FROM EXTERIOR) viol# iiXii ANCHOR LOCATIONS FOR FLAN E M UNT INSTALLATION C,L, OF ANCHOR STRAP 2. 'FASTENER 6."OFF ENCENTERS IN N { ALL FLANGE DSS] T —' 3 ANCHOR STRAPS FLAGE UNITS C. L. OF ANCHOR STRAP i (TYP.) z ALL FLANGE UNITS OVER 48" WIDE I C. L. OF ANCHOR STRAP b OW" OFF ENDS ALL FLANGE UNITS) FLORIDA FLANGE UNITS- REFER TO ADJACENT ELEVATION FOR SPACING UNIT HEIGHTS NO, OF INTERIOR ANCHORS PER JAMB INTERIOR JAMB ANCHOR TYPE 36"- 48" 3 1/4" TAPGON X 2 1/4" LG. 49"- 60" 3 „ b 1 "-72" 3 73"- 84" 5 85"- 94" 5 UNIT WIDTHS NO. OF ANCHORS PER HEAD NO. OF ANCHORS PER SILL ANCHOR TYPE -HEAD ANCHOR TYPE -SILL 24"- 36" 2 2 1/4"TAPCON X 2 1/4" LG. )/4"TAPCONS INTO STRAP ANCHOR 37"- 48" 2 2 „ 49"- 6U'; 3 3 CONCRETE FILLED CELL POUR w/ ( 1) #5 VERTICAL BAR 1/ 4" x 2-1/2" CONCRETE SCREW SEE MFG. SPECS FOR SPACING MINIMUM 1-1/4" EMBEDMENT) TYPICAL DOOR JAMB CAULK ENTIRE UNIT n/ Door Buck Repair Detail 1 1/2" = 1'-0" CONCRETE FILLED CELL POUR w/ ( 1) #5 VERTICAL BAR 1/ 4" x 3-3/4" CONCRETE SCREW MINIMUM 1-1/4" EMBEDMENT) CAULK PERIMETER TYPICAL WINDOW UNIT WOOD SCREW SEE MFG. SPECS FOR SIZE AND SPACING) 1x6 WOOD FILLER 2x6 WOOD PT WOOD BUCKING WRAPPED WITH ALL WEATHER FLASHING TAPE 1x WINDOW TRIM CAULK PERIMETER e Exterior Exterior 1/ ow Buck Repair Detail C1'-0" m ANCHOR EMBEDMENT AND EDGE DISTANCE: MINIMUM PENETRATION FOR BLOCK CONSTRUCTION: " 1 J4' MINIMUM PENETRATION FOR FRAME. 1 1/2" MINIMUM EDGE DISTANCE FROM BLOCK: 1 1/2" MINIMUM EDGE DISTANCE FROM FR,,kME. i 1/2" Ell ` rHINISKIT - 321- 863-3223 NTERPRISES, LLC Descri Seal Date Addition for Wachsmuth Residence 2030 Jefferson Avenue Sandford, Florida 32772 c c Window & Door Details Project number 11-0422 Date 8/20/11 C_3 Drawn by Author V Checked by Checker Scale 1 1/2" = 1'4" Florida uildinc, Code Online ®FF E http://www.floi-idabuildinc,.or./pr/pr_app_dtl.aspx?paf-am=w... x• ''g N n C I t s F t ta`€F + d Y E BCIS Home Log In User Registration Hot Topics Submit Surcharge Slats & Facts Publications FBC Stag BCIS Site Map Links Search i 1 o eSSj01 I @ USER: P Product User al •. Al LPmfll -3 r` d Pre6uctApt:iovaiMwu>Picduci0,ApplicationSearch>Aoclica;iciList > Application Detail NOV0 i011 rs S 'v Y L FL # FL10674-R5 Application Type Revision — t Code Version 2007 Application Status Approved Approved by DCA. Approvals by DCA shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments I- 1q7d 1 of 2 Archived El Product Manufacturer Address/ Phone/Email Authorized Signature Technical Representative Address/ Phone/Email Quality Assurance Representative Address/ Phone/Email Category Subcategory Compliance Method Owens Corning One Owens Corning Parkway Toledo, OH 43659 419) 376-8360 mel. sancrant@owenscorning.com Darrel Higgs darrel. higgs@owenscorning.com Darrel Higgs One Owens Corning Parkway Toledo, OH 43659 419) 248-7060 darrel. higgs@owenscorning.com Roofing Asphalt Shingles Certification Mark or Listing Certification Agency Underwriters Laboratories Inc. Validated By Robert J. M. Nieminen, PE Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard ASTM D3161, Class F ASTM D3462 ASTM D6381, Class H ASTM D7158, Class H 0j, ] l Year 2003 2004 2003 2005 11/ 03/2011 12:10 AM Floiida;:uildinc, Code Online http://www. fl on dabui 1 di nC. org/pr/pr_app_dtl . asp0paratn =w... Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products TAS 107 UL 2390, Class H Method 1 Option A 07/20/2011 07/20/2011 07/25/2011 1995 2004 FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, laminated, starter, and hip & ridge Shingles and Starters Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10674 R5 C CAC AHJ letter 2-21-11.pdf Approved for use outside HVHZ: Yes FL10674 R5 C CAC UL Certification DOcuments.pdf Impact Resistant: N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 02/21/2012 Other: Refer to UL Certification uploads for fastening Installation Instructions requirements and substrate limitations. FL10674 R5 II BERKSHIRE SHINGLES.pdf FL10674 R5 11 DURATION SHINGLES.pdf FL10674 R5 II HIP RIDGE SHINGLES.pdf FL10674 R5 II OAKRIDGE SHINGLES.pdf FL10674 R5 II STARTERS.pdf FL10674 R5 II THREE -TAB SHINGLES.pdf FL10674 R5 II WEATHERGUARD HP.pdf Verified By: Underwriters Laboratories Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webmaster@dbpr.state.fl.us. Product Approval Accepts: 5.. *.!• scA "a IN ct ttritl + Ve tsig4 1 Tru lted 4 _ w v!xap!k 2 of 2 1 1 /03/201 1 12:10 AM Plans Examiner,:Jj,,y ' 1 Application #: 1C - 3 Project Address: Z:) 3a Contact Person: Contact Phone #: City of Sanford Building & Fire Prevention Division Response to Comments Date:Submittal NOV 12011 BY:_ 11-0/. i/ Quote ` http://sstsrv.Iowes.com/m2o_a/mediumQuote. jsp?projectld=10... Back to Qttote LOWE'S HOME CENTERS, INC. #1657 3780 ORLANDO DRIVE SANFORD, FL 32773 USA Date: 10/31 /201 1 407) 430-4060 Project #: 339408412 Description: doors Customer Name: SABINEWACHSMUTH Customer Phone: 407) 620-9436 CustomerAddress: NA SANFORD, FL 32773 USA Line Item Product Code Frame Size Description 0002 Manufacturer: Reliabilt by JELD-WEN Millwork Masters O Size = 60" W x 80" H Patio Doors ivision: Millwork Yoduct: Doors Iype: Patio Qanufacturer: Rel iabilt by JELD-WEN Millwork Masters atio Doors nergy Efficient Options: No 5roduct Style: Door Yoduct Design: French onfiguration: Door Unit toom Description: Other 1 atio System Layout: Double oorMaterial: Steel landing: 26 RH US xterior Door Finish Type: None nterior Door Finish Type: None ize Application: Retro tough Opening Width: 60" tough Opening Height: 80" Jnit Width: 59 1/2" Jnit Height: 79 1 /2" 3rickmould Width: 62" 3rickmould Height: 80 3/4" mpact Glass Option: Standard Glass itePattern: 10 Lite External Grille nsert Frame: Standard Glass Frame Mass Option: Tempered I.G. singe Finish: Light Brass Hinges xterior Frame Finish Type: None III-_- LV 1\11 LJ Unit Price Quantity Total Price r - qc- ` 1 of 4 10/31 /201 1 10:50 PM I Quote P http://sstsrv.Iowes.com/m2o_a/mediumQuote.jsp?projectId=10... nteriorFrame Finish Type: None amb Species: Primed amb Width: 4 9/16" xteriorTrim: No Brickmould Weatherstrip: White Compression ill Style: Adjustable Vinyl Cap Sill ill Finish: Aluminum ill Pan: No icreen Type: None Sore: Double ockSet: No Lockset ead Time: 18 Days Picture is not an exact represntation of the unit that has een ordered. *** flit is built to spedifications given in the configurator. k you for ordering aReliabilt Entry Door product by WEN. O CatatloQ Version: 2.36.0*"' Manufacturer: ReliabiIt by Masonite Division : Millwork Product : Doors Type: Entry/Exterior Energy Star Compliant Products : Yes (Energy Star Product) Configuration : Single Unit Material Type: Steel Door Material : Steel Finish : Unfinished Doorwith Glass: Clear Door Style: Half Lite Glass Family : Vent Lite Glass Type: Clear Insulated Handing: Right lnswing Sill Style: Mill Finish Slab Width : 36" Rough Opening Width : 38 1/4" Height Type: Standard Slab Height: 79" Rough Opening Height : 82 1/8" Jamb Finish : Unfinished Jamb: Primed Jamb Size: 4 9/ 16" Brickmould : No HingeType: Brass (standard) Bore: Double Product Approval Number4904.6 . 280.90 1 $280.90 2 of 4 10/31/201 1 10:50 PM Quote http://sstsrv.Iowes.com/m2o_a/mediumQuote.jsp?pi-ojectId=10... rder : No Time: 12 days This Product is an Energy Star Compliant roduct**** UNIT WILL BE DELIVERED PRIMED.*** Picture is not an exact representation ofthe unit that is been ordered. *** nit is built to specifications given in theconfigurator. hank you for Ordering a Rel i abi l t by Masoni to Product. Manufacturer: Reliabilt by Masonite iivision : Millwork roduct : Doors ype: Entry/Exterior nergy StarCompliant Products : Yes (Energy Star Configuration : Single Unit Material Type: Steel Door Material : Steel Finish : Unfinished Door with Glass : Decorative Door Style: 3/4 Oval Glass Family: Hampton Caming Style: Patina Lite Frame Surround Option : Frame with Plugs Handing : Right Inswing Sill Style: Mill Finish Slab Width: 36" Rough Opening Width: 38 1/4" Height Type: Standard Slab Height : 79" Rough Opening Height: 82 1/8" Jamb Finish : Unfinished Jamb: Primed Jamb Size: 4 9/16" Brickmould : No Hinge Type : Standard (matches caming color) Bore: Double Product Approval Number: 4904.6 Re -Order: No Lead Time: 12 days This Product is an Energy Star Compliant UNIT WILL BE DELIVERED PRIMED.` 414 3 of 4 10/31/201 1 10:50 PM BolseCascade Double 1-3/4" x 14" VERSA-LAMO 2.0 3100 SP Roof Beam\RB01 BC CALCO 3.0 Design Report - US 1 span No cantilevers 1 0/12 slope Monday, October 31, 2011 Build 440 File Name: 17474 WACHSMUTH RES.BCC Job Name: Description: R601 Address:OFFICE Specifier: City, State, Zip: , Designer: 'p' Customer: Company: E p Code reports. ESR-1040 Misc: o n r.5.. r z .a* ?` F„k. s( z §z 17-nn-nn BO DL 2,888 Ibs RLL 3,153 Ibs Total of Horizontal Design Spans = 17-00-00 B1 DL 2,888 Ibs RLL 3,153 Ibs Live Dead Snow Wind Roof Live Trib. (in.) Load Summary Tag Description Load Type Ref. Start End 100% 90%. 115% 133% 125% 1 Standard Load Unf. Area (psf) L 00-00-00 17-00-00 10 0 01-00-00 2 ROOF Unf. Lin. (plf) L 00-00-00 17-00-00 204 239 n/a 3 EXISTING Unf. Lin. (plf) L 00-00-00 17-00-00 112 132 n/a Controls Summary Value Allowable Duration Case Span Pos. Moment 25,678 ft-Ibs 70.7% 125% 5 1 -internal End Shear 5,161 Ibs 44.3% 125% 5 1 - Left Total Load Defl. U244 (0.834") 98.2% 5 1 Live Load Defl. U468 (0.436") 76.9% 5 1 Max Defl. 0.834" 83.4% 5 1 Span / Depth 14.6 n/a 1 Cautions For roof members with slope (1/4)/12 or less final design must ensure that ponding instability will not occur. For roof members with slope (1/2)/12 or less final design must account for Rain -on -Snow surcharge load. Notes Design meets User specified (U240) Total load deflection criteria. Design meets User specified (U360) Live load deflection criteria. Design meets arbitrary (1") Maximum load deflection criteria. Minimum bearing length for BO is 2-5/16". Minimum bearing length for B1 is 2-5/16". Entered/Displayed Horizontal Span Length(s) = Clear Span + 1/2 min. end bearing + 1/2 intermediate bearing Connection Diaaram b d a c e o a a minimum = 2" ...c ::=:5" b minimum = 3" d =12" Member has no side loads....;..::i_. Connectors are: 16d Common Nails Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code -accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call 800)232-0788 before installation. BC CALCO, BC FRAMER®, AJS-, ALLJOISTO , BC RIM BOARD-, BCI@ , BOISE GLULAMTM, SIMPLE FRAMING SYSTEM@ , VERSA -LAM@, VERSA -RIM PLUS@ , VERSA -RIM@, VERSA -STRAND@, VERSA -STUD@ are trademarks of Boise Cascade, L.L.C. Page 1 of 1 _ -, SUPPORT REPORT JOB DESCRIPTION: 17474 WIND CODE: WIND MPH: 120 BLDG TYPE: CLOSED TRUSS TRUSS SUPPORT SUPPORT BEARING BEARING REACT. REACT. MAX WIND DESC SPAN-ft SIZE -in. TYPE XLOC-ft. YLOC-ft. MAX.+# MAX.-# UPLFT.-# C1 22.50 7.00 WALL 0.000 8.000 991 238 Cl 22.50 7.00 WALL 21.917 8.000 990 204 C2 22.50 7.00 WALL 0.000 8.000 976 235 C2 22.50 3.50 WALL 21.917 8.000 907 184 C3 21.92 7.00 WALL 0.000 8.000 978 236 C3 21.92 3.00 HANGER 21.854 8.000 881 173 GE1 22.50 270.00 WALL 0.000 8.000 1981 441 GE2 22.50 263.00 WALL 0.000 8.000 1876 409 GE2 22.50 7.00 WALL 21.917 8.000 15 7 HANGER denotes a hanger calculated by the layout program. Refer to the layout HANGER SCHEDULE for complete list of hangers and nails required. 17474-Owner Bldr Wachsmuth res -- 2030 Jefferson Ave - C1) THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY T USS MFR. Top chord 2x4 SP M-31 :T2 2x4 SP #1: 120 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED Bldg, Located Bot chord 2x4 SP #2 anywhere in roof, CAT I1, EXP B, wind TC DL=4.2 psf, wind BC DL=5.0Webs2x4SP #3 :W2, W6 2x4 SP #2: psf. Iw=1.00 GCpi(+/-)=0.18 Roof overhang supports 2.00 psf soffit load. Wind loads and reactions based on MWFRS with additional C&C member design. Max JT VERT DEFL: LL: 0.35" DL: 0.36" recommended camber 5/8" a) #3 or better scab brace. Same size & 80% length of web member. Bottom chord checked for 10.00 psf non -concurrent live load. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC. Deflection meets L/360 live and L/240 total load. PROVIDE FOR ADEQUATE ROOF DRAINAGE. IF PARAPET WALLS OR CONDITIONS EXIST THAT RESTRICT FREE RUNOFF OF WATER, DRAINS AND SCUPPERS MUST BE PROVIDED THAT WILL ALLOW COMPLETE DRAINAGE. Roof application only. A MIN. ROOF SLOPE OF 0.25" PER LINEAR FOOT MUST BE PROVIDED THIS TRUSS IS NOT DESIGNED FOR PONDING. PROVIDE FOR COMPLETE DRAINAGE OF TRUSS. i 3X4= i I 0.25 _ 3X4= 1.5X3111 T2 6X6= 5X8= 1 0 W6 1 9 10 Ion a) 8-0-0 5X8= H0308= 6X12= 2 X 8 III 2 X 8 III L-5 Q'i 1 5 0- LE 22-6-0 Over 2 Support I 1 R=991 U=238 W=7" P P, R=990 U=204 W=7" Design Crit: FBC2007Res/TPI-200 STD•' I PLT TYP. ZO Gauge HS,Wave FT RT=20% OD/p 10 10Kf TY:3 FL 3 R Scale=.3125" Ft. WARNING"= READ AND FOLLOW ALL NOTES ON THIS SHEET! LUD T C L L 20.0 P S F R E F R 6 6 6 6- j5 4 7 7 5INPURTANT** FURNISH THIS BESIGN TO ALL CONTRACTORS INCING INSTALLERS. rrp:: e: re Pita a=creme tare in fa.ricating, antlling, shIpPL19, 1ns[alling and br far to a y T C D L 10. 0 P S F DATE 10 / 2 8 followthelatesteUitlonofBCsI (D ulldtng tom pu nent safety Infor matio m, Uy TPI anH o ming these func[1Pns. Installers shall provide temporary bi CAI fo sat Y Ing pet. BC DRW HCUSR6666 11301001 practicespriorperforUnless noted otherwise. top chord shall nave properly a[[a<hetl structural she "InI ng a hall have a properly attached rigid caning. Locations shown for permanent lateral I L,j 11pV rtl tr ket. aj weUs j+(/ j TE r Eft d',V• Bl. DL 100 PSF H C- E N G D R/ W P F shall have bracing installed per BCSI sections B3. B7 or BID. as applicable. N Bun ding ComPonenes Group Inc. (1ruBCG1 shall not be responsible f.r deviation 1°. V B C L L 0 .0 P S F ALPINEany failure to build the truss in conformance with ANSI/TPI 1, or far handling, shippl ny. Y. bracing or truss s. APPIy plates to each fate of Vuss and poll ttPn as shown above and o0 .i / Details, unless noted oCherwl se. Refer to drawings 1GOA-2 far standard plate posl [I ons. AL\1' TOT. L D . 40.0 P S F S E Q N - 8001 0 D U R . F A C . 1.25 FROM M C IBuildingcomponentsGroupno. drawtng or cover page listing this tlr awt mg, indicates acceptance of prole sslonaI engineerIng VMS rapnsibilitysolelyforthedesignshown. The suitability and Is, of this design for any st-C _ Haines City, FL 33844 the responsl bl'Ity of the Building Designer per AN11/TPI I Sec.2. For m e information see: This Jo genera, notes page: ITN-BCG: www.i[wbcg.com; TPI: www.[pins[.prg; NTCA: www.sUclndustry.Co.; 10728720iI SPACING 24.0" JREF lUGK66i66Z01 FLCOA# 0278 ICC: w w.it°,are.org u 17474-Owner Bldr Wachsmuth res -- 2030 Jefferson Ave - C2) Top chord 2x4 SP M-31 :T2 2x4 SP #2: Bot chord 2x4 SP #2 Webs 2x4 SP #3 :W2 2x4 SP #2: Right cantilever is exposed to wind Roof overhang supports 2.00 psf soffit load. a) #3 or better scab brace. Same size & 80% length of web member. Attach with 10d Box or Gun (0.128"x3",min.)nalls @ 6" OC. Deflection meets L/360 live and L/240 total load. PROVIDE FOR ADEQUATE ROOF DRAINAGE. IF PARAPET WALLS OR CONDITIONS EXIST THAT RESTRICT FREE RUNOFF OF WATER, DRAINS AND SCUPPERS MUST BE PROVIDED THAT WILL ALLOW COMPLETE DRAINAGE. Roof application only. A MIN. ROOF SLOPE OF 0.25" PER LINEAR FOOT MUST BE PROVIDED THIS TRUSS IS NOT DESIGNED FOR PONDING. PROVIDE FOR COMPLETE DRAINAGE OF TRUSS. 6X6= 0.25 — 3X4= THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TFOSS MFR. 120 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=5.0 psf. Iw=1.00 GCpi(+/-)=0.18 Wind loads and reactions based on MWFRS with additional C&C member design. Max JT VERT DEFL: ILL: 0.34" DL: 0.34" recommended camber 5/8" Bottom chord checked for 10.00 psf non -concurrent live load. 3X4= 4X8= T2 1.5X3 III 1TI I L__j 0 21 (a) 6X6= H03083X4= 2X8111 4X8 1 9 l 8- 0-0 5 0 0 3t8 22- 6-0 Over 2 Support _I R= 976 U=235 W=7" W=3.5" Design Crit: FBC2007Res/TPI-200 STD o ; PLT TYP. 20 Gauge HS,Wave FT RT=20% O/10 TY:2 FL 3 R - Scale WARNING -" READ AND FOLLOW ALL NOTES ON THIS SWEET' IMPORTANT'* FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS. Trusses regutre extreme care 1n fabrlca[Ing. handling, slilppL,g. Installing and br -n {4 fer co a follow the latest edition .1 BC51 (Builtll ng component Safety Infor ma clan, b, TPI and -CAI fo - v prat [ l ces trial co performing these Yu nc [tans. Installers snail provide temporary b Ing Rem 8C Unless noted o[nerwlse. cot chord shall nave proterlY attacned scructurai sneath"" a D c ph ra shall nave a properly attached rigid telling. Locations s1—h for permanent lateral r I 3Y L of webs r r + i E 0 ; , at. L'/t/• T C ILL TlJ D L BC DL 20 . 0 10 0 10. 0 P S F P S F PSF R E F R 6 6 6 6- 5 4 7 7 6 DATE 1 0 2 8 1 I DRW HCLISR6666 11301002 I H C - E N G D R / W P-F ALPINE 7iBUilding shall nave bracing Installed per BCSI sections B3. B] or BID. as applicable. J W Builtlin9 Components Group Inc. (,TWBCG) shall net be responsible far any devlatton ' g dny ran ure [o build [he truss In conformance wltn ANSI/TPI 1. or for noodling. sNlppiny. br a ctng or trusses. Aptly places co eachface of cra.: and to s, t, on as shown above ana o, ,+QT / Details, unless noted ,th er.ise. Hefer to 1 ..i n.. 1GOA-Z for s[aodard plate posl tl on s. ,A t\T 0 I r r+ era• B C L L T 0 T . L D . 0 . 0 40 . 0 P $ F P S F S E Q N - 80015 D U R . F A C . 1 .2 5 FROM M C it componentsGroupno, Haines City, FL 33844 FLCOA# 0278 drawing or cover page listing this drawing, indicates acceptance of Drofesstonal engineering V responsibility solely for the design sh.,h. The sultaElllty and use of this design for any strut - the responsibility of the Building Designer per ANSI/TPI .. c.2. Far mare inf alma [i on see: Th1s Joj general notes page: ITN-BCG: .ww.1[wbcy.com; III: wwv.to'nst.arg; HTCA: vvw.so_indus[ry.cam: ICc: wwv.1c...fe.org AL It 1 0/2p/20 1 I SPACING 2 4. 0" J R E F- 1 U G K 6 6 6 6 Z 0 1 i TNTc nWr oq Cpa Con. r..pIITc. T—IT xnc c .. 1/4/4-uwner blar wachsmuth res -- 2030 Jefferson Ave - C3) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 :B2 2x4 SP #1: Webs 2x4 SP #3 :W2 2x4 SP #2: Roof overhang supports 2.00 psf soffit load. Max JT VERT DEFL: LL: 0.35" DL: 0.36" recommended camber 5/8" Bottom chord checked for 10.00 psf non -concurrent live load. Deflection meets L/360 live and L/240 total load. PROVIDE FOR ADEQUATE ROOF DRAINAGE. IF PARAPET WALLS OR CONDITIONS EXIST THAT RESTRICT FREE RUNOFF OF WATER, DRAINS AND SCUPPERS MUST BE PROVIDED THAT WILL ALLOW COMPLETE DRAINAGE. Roof application only. A MIN. ROOF SLOPE OF 0.25" PER LINEAR FOOT MUST BE PROVIDED THIS TRUSS IS NOT DESIGNED FOR PONDING. PROVIDE FOR COMPLETE DRAINAGE OF TRUSS. 3X4= 0.25 120 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, not located within 4.50 ft from roof edge, CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=5.0 psf. Iw=1.00 GCpi(+/-)=0.18 Wind loads and reactions based on MWFRS with additional C&C member design. a) #3 or better scab brace. Same size & 80% length of web member. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC. 3X4= 5 X 7 =_ 1.5X3111 11- 9 8-0-0 22-1-4 Over 2 Support R=978 U=236 W=7" ., 1 1`is R=881 U=173 Design Crit: FBC2007Res/TPI-2OO2 TD).-7 PLT TYP. 20 Gauge HS,Wave FT RT=20% Op/p 10 : io ft 22$i .12.E IT Y:9 FL 3 - R - Scale=.3125" Ft. WARNING— READ AND FOLLOW ALL NOTES ON THIS SHEET! 0 • T C L L 20 . 0 P S F IMPORTANT— FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS. : + R E F R 6 6 6 6- 54777 Trusses repulre extreme care In fabricating. handling, shipping, insta111ng and bra 9 R,.Pr to T C D L 10 .0 P S F DATE 1 0 / 2 8 / 1 1follow [he latest etli [ton of SCSI ........ uilding ComVonen[ Safety InPorma[lon, by TPI and 1 A) for %safe N p r acttces prior to performing these functions. Installers shall provlde temporary bra ,q'''ppe rer 11CS TE . Unless noted othe—Ise. top chord shall nave Properly attached structural sheacblhg a ow{y a ` J BC DL 10.0 PSF DRW HCUSR6666 11301003 shall nave a properly attached rlgtd Ceiling. Locations sbpwn for permanent lateral re 1. laL l ebs shall nave bracln9 Ins caned per SCSI sections810, as apPl,cablo B C L L 0. 0 P S F H C- E N G D R/ W P F ALPINE N Bulldln9 Components Gr"P Ina. (..W"') shall not be responsible for any deviation T es, A! R V any failure to build the truss 1n conror ma nce with ANSI/TPI 1, or for handling, shlVDl n9. 1 .,.,f m bracing of trusses. Apply plates to each rase of truss ana P-1 ti- - shown above ana cn Cr TOT. LID . 40.0 P $ F S E Q N - 80035 Details, unless noted otherwise. Refer to arawln9s 16DA-Z for standard plate posttl-S. A sea ( • e A drawl", or cov r page listing this drawing, Indtca tes acceptance of prone ssional engineering , pn 1 Building Components Group nc. respp"stbnitresplely rpr the desl9n snpwn. The spttab n ity a"ape pr tnts design rpr any scrptcpr D U R . F A C . 1.25 FROM MC the re spo"stbtlity of the BU1ltling Designer per ANSI/TPI t Sec.2. s'or more inf or ma tton see: This Job's 1 D/•10 /•1Q1 1 Haines City, FL 33844 general "pies page: ITN-BCG: w...1t_p .to.: IPi: www.tpinst.orq; NTCA: www.sbcindustry.cpm; I LO L SPACING 2 4. 0" J R E F 1 U G K 6 6 6 6 Z 0 1 FLCOA#0278 ICC: w w.icc,,fe..rq THIS DWG PREPARED FROM COMPDTFR 1NPHT rl nant R nTMFNCTONCT CNQMTTTFn Rv TP11— Mrp Lit— uwutor olur Vld(. 11l5mulll 1'eb -- euiu JeTTerson Ave - lTtl Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Roof overhang supports 2.00 psf soffit load. See DWGS A12015050109 & GBLLETIN0109 for more requirements. Deflection meets L/360 live and L/240 total load. PROVIDE FOR ADEQUATE ROOF DRAINAGE. IF PARAPET WALLS OR CONDITIONS EXIST THAT RESTRICT FREE RUNOFF OF WATER, DRAINS AND SCUPPERS MUST BE PROVIDED THAT WILL ALLOW COMPLETE DRAINAGE. Roof application only. A MIN. ROOF SLOPE OF 0.25" PER LINEAR FOOT MUST BE PROVIDED THIS TRUSS IS NOT DESIGNED FOR PONDING. PROVIDE FOR COMPLETE DRAINAGE OF TRUSS. 3X4= 120 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=5.0 psf. Iw=1.00 GCpl(+/-)=0.18 Wind loads and reactions based on MWFRS with additional C&C member design. Bottom chord checked for 10.00 psf non -concurrent live load 3X4= 0.25 3X4= 1 T O 1.5X4111 1YA— 3X4= 3 X 4 =_ Q_1_Q1+ 22-6-0 Over Continuous Su R=88 PLF U=20 PLF W=22-6-0 Note: All Plates Are 1.5X3 Except As Shown. Design Crit: FBC2007Res/TPI-200 STI PLT TYP. Wave FT RT=20%(O%) 10 WARNING— READ AND FOLLOW ALL NOTES ON THIS SKEET! IMPORTANT*" FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS. ; Trusses "I'll, extreme rca a 1n f.Drlcating, ha nUling. shipping, tns[a111 ng and DfallowthelatesteU1 [Ion ofBEST IB u/1Uing E.4 ne nt Safely [nf orma Llan. Dy TPI a 17 (y prat tl ces prlor t1 De rf Ormtng In— functlons. Installers mall prDvlde to mporaryn cing 'I U.- notes of h1-1-. top chord snail nave properly attached structural sneatht ,1 0 botto snail have a properly attached ri giU ceiling. Locations shown ror permanent lateral sin shall nave bracing Installed per BCSI sections 83. B] ar B10, as applicable. I{ yy ALPINE ITN Building Components Group Inc. (ITWBCG) sbal, "" be resDonslble ror any devlatl any failure to Dulld the truss In conformance u,In ANSI/TPI I. or ror handling, sntppin Dracing of trusses. Apply Vidtez tD each race of truss ano pal tlon as shoRn above and tt Details, unless noted athervise. Refer to dr—Ings IGOA-Z for standard plate position i. drawing or cover page Ilz[1 ng this dra vl ng. Indicates acceptance or pro/e ss10 nai engineering I Building Componemd Group nc. responzfDnity solely ror the de sl 9n snoNn. The su1[aLi ll [y ana use o! this design for any z the resP-11,tllty Of the Bullding Designer per ANSI/TPI 1 Sec.2. For 'or' inf Or motion s Haines City, FL 33844 genera, hates Dage; ITM-BEG: _ ltsbc9.con; TPI: to I.— NTCA:--oc-u-Iry.com; FL COA #0278 ICC:.,....Itt,afe.org P. 1 02 9.iz efjt. d4- aID F.-- 0 s. 11VALi hi 10 10/ 28/201 I 1. 5X4III L- 1-5-Q'i QTY: 1 FL 3 R TC ILL 20.0 PSF TC DL 10.0 PSF BC DL 10.0 PSF BC LL 0.0 PSF TOT. LD. 40.0 PSF DUR. FAC. 1.25 SPACING 24.0" 1- 9 10 8- 0-0 Scale=. 3125"/Ft. REF R6666- 54778 DATE 10/28/11 D R W HCUSR6666 11301005 HC- ENG DR/WPF SEQN- 80011 FROM MC JREF- 1UGK6666Z01 THIS DWG PREPARED FROM COMPUTER INPUT !LOADS & D7MFNSIONSI SHRMITTFD Rv TRH q MFR i/4/4-uwner bear wacnsmuth res -- 2030 Jetterson Ave - GE2 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Roof overhang supports 2.00 psf soffit load. Gable end supports 8" max rake overhang. Bottom chord checked for 10.00 psf non -concurrent live load. PROVIDE FOR ADEQUATE ROOF DRAINAGE. IF PARAPET WALLS OR CONDITIONS EXIST THAT RESTRICT FREE RUNOFF OF WATER, DRAINS AND SCUPPERS MUST BE PROVIDED THAT WILL ALLOW COMPLETE DRAINAGE. Roof application only. A MIN. ROOF SLOPE OF 0.25" PER LINEAR FOOT MUST BE PROVIDED THIS TRUSS IS NOT DESIGNED FOR PONDING. PROVIDE FOR COMPLETE DRAINAGE OF TRUSS. ItaY4E 1 T O 1.5X4III 3X4= 3X4= 120 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED Bldg, Located anywhere 1n roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=5.0 psf. Iw=1.00 GCpi(+/-)=0.18 Wind loads and reactions based on MWFRS with additional C&C member design. See DWGS A12015050109 & GBLLETIN0109 for more requirements. Deflection meets L/360 live and L1240 total load. 3X4= 0.25 22-6-0 Over 2 Supports 3X3= 3X4= R=86 PLF U=19 PLF W=21-11-0 4`9 ? ;f R=15 U=7 W=7" 1-9 10 8-0-0 Note: All Plates Are 1.5X3 Except As Shown. ; Iy'ti,j+,J. Design Crit: FBC2007Res/TPI-200 ST +• 0 PLT TYP. Wave FT RT=20%(O%) /10 1 2 9 JQTY:1 FL - 3 R - Scale=.3125" Ft. WARNING— READ AND FOLLOW ALL NOTES ON THIS SHEET! ' TC LL 20.0 PSF REF R6666 54779 IMPORTANT" FURNISH THIS DESIGN TO ALL CONTRACTOR S INCLUDING INSTALLERS. r rrpsses respire eareme to a in fabricating, handling. shipping. Installing ana b iice r, defer to - a '+ . TC D-L 10.0 PSF DATE 1 Q 2 8 1 1followu,e rarest edl Iron of rats! !Bpi !ding component safety Inrorma tion. br TP1 an iT[,4f rrr W Ir f prat [lees prior fo performing these font!lass. Installers shall or o i de temporary ct ng P%r SC Unless noted otherwise, IOD thurd shall have properly .[!ached structural sheath!ng " bp[[gi c pr, ^ has nave a properly attached rigid cell,ng. Locations snows for permanent lateral !•o we f * t!. BC DL 10.0 PSF DRW HCUSR6666 11301004 shall have bracing installed per SCSI sections 63. B] or BID. as appllcable. ALPINE ITN Iullling Co'Dpnents UrouD Inc. (ITNBCGI ,hall not be respona,ble for am deviati 7 1, . B C L L 0.0 P S F H C- E N G D R/ W P F lai lure to ball. the truss in conformance will, ANSI/TPI 1, or for ha nJltng, shl ppin TM' t1• or ling of tros . Apply plate, to each fate of trpss and Position - ,how" ao"1 and o 4•,••'' TOT. LD. 40.0 PSF SEQN 80012 Detarls. pnleas noted otherwise. Refer to drawings 16OA-z for standard plate positions. drawing or raver page listing th15 drawing, indicates acceptance of professional engineering hj / 7111. dinComponents Group ne. r p.nslbTTltr solely far ule des,gn shDwn. The spitabnitr ana p e pr tnia design for am stl `F11, OUR FAC. 1 .25 FROM MC he respon s10111tr of Cl,e Building Designer per ANSI/TPI I Sec .2. sFor more inf orma [ton see: Tliis KO/2 HainesCityFL33844generalnoteVage: ITN-SCG: www.itwbcg.com; TPI: www.[pinsL ors; NTCA: www.sbolnduslrr.tom: I8/20 1 1 SPACING 2 4. 0" J REF - l U G K 6 6 6 6 Z 0 1 FLCOA#0278 ICC: www.lccsafe.org ASCE 7-05 GABLE STUD REINS RCEMENT DETAIL 120 MPH WIND SPEED, 15' MEAN HEIGHT, ENCL SED, I = 1,00, EXPOSURE C, Kzt = 1.00 F- RACE GABLE VERTIC 2X4 rGRADESPACINGSPECIES NO BRACES 1) 1X4 'L' BRACE x 1) 2X4 'L' BRACE - 2) 2X4 'L' BRACE wx 1) 2X6 'L' BRACE A 2) 2X6 'L' BRACE GROUP A GROUP B GROUP A GROUP B GROUP A GROUP B GROUP A GROUP B GROUP A GROUP B E 2 3' 7' 6' 3" 6' 5' 7' 4" 7' 7° 8' 9' 9' 0" 11' 7' 11' 11" 13' 9" 14' 0" Z S r 3' 6' S' S' S' S" 7' 2" 7' 2" 8' 9" 8' 9" 11' 1' 11' 1" 13' 9" 13' 9' LL) STUD 3' 6° 5' 4" 5' 4" 7' 1' 7' 1" 8' 9" 8' 9" 11' 1" 11' 1" 13' 9" 3' 9° STANDARD 3' 6" 4' 7" 4' 7' 6' i' 6' 1" 8' 2" 8' 2" 9' 6" 9' 6" 12' 11" 12' 11" 1 3' 11' 6' 3" 6' 8" 7' 4' 7' 11" 8' 9" 9' 6" 11' 7' 12' 6" 13' 9° 14' 0" J S P 2 3' 10" 6' 3` 6' 8" 7' 4" 7' 11" 8' 9' 9' 6" 11' 7' 12' 6` 13' 9" 4' 0" 3 3' 8 5' 6' 5' 6' 7' 4" 7' 4' 8' 9" 9' 3" IV 5" 11' 5" 1 13' 9" 14' 0" lf D P L STUD 3' 8' 5' 6" 5' 6' 7' 3" 7' 3" 8' 9' 9' 3" 11' 3" 11' 3" 13' 9" 14' 0" U STANDARD 3' 7' 4' 9" V 9" 6' 3" 6' 3" 8' 5' B' S" 9' 9' 9' 9" 13' 2' 13' 2" 1 / #2 4' 1" 7' 1' 7' 4" 8' 5" 8' 8" 10, 1' 10' 4" 13' 3' 13' 7' 14' 0" 14' 0" S P P 3 4' 0" 6' 7" 6' 7' 8' 5" 8' 5" 10, 1' 10, 1" 13' 3" 13' 3" 14' 0" 14' 0" U I L STUD 4' 0' 6' 7" 6' 7" B' 5° 8' 5' 10, 1" 10, 1" 13' 3" 13' 3" 14' 0' 14' 0" LLl I - STANDARD 4' 0' 5' 8" 5' 8" 7' 6" T 6' 10, 1" 10, 1' 11181 11' 8" 14' 0" 14' 0" 1 4' 6' 7' 1' 7' 8" 8' 5" 9' 1' 10' 1' 10' 10" 13' 3" 14' 0" 14' 0" 14' 0" S P 2 4' 5' 7' 1' 7' 8" 8' 5" 9' 1" 10, 1' 10, 10" 13' 3" 14' 0" 14' 0" 14' 0" 3 4' 3' 6' 9" 6' 9' 8' 5" 8' 11' 10, 1' 10' 7" 13' 3" 13' 11' 14' 0" 14' 0' D P L STUD 4' 3' 6' 9" 6' 9' 8' 5" 8' 10, 10' 1" 10' 7° 13' 3' 13' 9" 14' 0' 14' 0" STANDARD 4' 1" 5' 10' 5' 10' 7' 8" 7' 8" 10, 1' 10' 3" 11' 11" 11' Ill 14' 0' 14, 0" 1 / #2 4' 7' 7' 10' 8' 1' 9' 3' 9' 6" 11' 1" 11' 5' 14' 0" 14' 0" 14' 0' 14' G" Q S P P 3 4' 5" 7' 8" 7' 8' 9' 3' 9' 3' 11' 1' 11' 1" 14' 0' 14' 0" 14' 0' 14' G" LD HF STUD 4' 5' 7' 7" 7' 7" 9' 3' 9' 3' 11' 1' 11' 11 14' 0' 14' 0" 14' 0' 14' 0" 0 STANDARD 4' 5" 6' 7' 6' 7" 8' 8" 8' 8" I1' 1' I1' 1" 13' 5" 13' 5" 14' 0' 14' 0" 1 5' 0" 7' 10" 8' 5° 9' 3" 10, 0' 11' 1' 11' 11" 14' 0" 14' 0" 14' C" 14' 0" Q S P 2 4' 10' 7' 10" 8' 5" 9' 3' 10' 0" 11, 1' 11, 11, 14' 0" 14' 0" 14' 0" 14' 0" 3 4' 8' 7' 10' 7' 10' 9' 3' 9' 9" 11, 1' I1' 8' 14' 0" 14' 0" 14' G" 14, 0" D L L STUD 4' 8' 7' 9" 7' 9" 9' 3" 9' 9" 11, 1' 11' 8" 14' 0' 14' 0' 14' 0" 14' 0" STANDARD 1 4' 7' 1 6' 8" 6' 8" 8' 10" 8' 10' 11' 1' 11' S" 13' 9" 1 13' 9" 1 14' 0" 14' 0" YMM ABOUTi 2X4 #2N OR BETTERGABLETRUSS DIAGONAL BRACE OPTION: T VERTICAL LENGTH MAY BE 18, iK DOUBLED WHEN DIAGONAL L 1 BRACE IS USED. CONNECT DIAGONAL BRACE FOR 74D# BRACE KWATEACHEND. MAX WEB TOTAL LENGTH IS l4'. 2X4 SP OR DF-L STUD tl OR #3, SPF #1/442, H-F 42 ]g° VERTICAL LENGTH SHOWN OR BETTER DIAGONAL L IN TABLE ABOVE, BRACEI SINGLE OR DOUBLE CUT (AS SHOWN) AT UPPER END, A I r CONNECT DIAGONAL AT REFER TO C i GE A14 MIDPOINT OF VERTICAL WEB. s wWARNINGww RSA AND FOLLOW ALL NOTES ON THIS SHEETI i Trusses require extreme core in fabricating, handling, shipping, installing and b—in Refer. to and Follow BCSI (Building Component Safety Information, by TPI and WTCA) For safety p tices Jr- to performing these functions. Installers shall provide temporary bracing per BCSI. l eted otherwise, top chord shall have properly attached structural panels and bo tton c rJ'Rh IF - properly attached rigid ceiling. Locations shown for permanent lot eral restraint o webs slwll e BCSI B3 & B7. See this notes orfo rip.— to rT_Ebracinginstalledpersectionsjob's general page INSTALLATION CONTRACTOR.TM '{J wwIMPOilding • FURNISH COPY OF THIS DESIGN ` ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any de via tlo hia Building Components Group Inc. design, any failure to build the truss in conformonce with TPI, or fabricating, handlin//}(yyyy{g } installing & bracing of trusses. ITWBCG connector plates are made of 20/18/166A (W,H 3 i grade 37/40/60 (K/W/H,S) galy. steel. Apply plates to each face of truss, positioned a . .0...( and on Joint Details. A seal on this drawing orcoverpage indicates acceptance and professional engineering res A1. forthetrussdesignshown. The suitability and use of this component for J7911i'1` solelycomponentbuilding is the responsibility of the Building Designer per ANST/TPI 1 Sec. 2. j Earth City, MO 63045 ITW-BCG: w,..itwbcg,comj TPI, www.tpinst.co ; WTCA: vww.sbcindustry.c—, ICC: www.:ccsafe.org a LENGTH, BRACING GROUP SPECIES AND GRADES: GROUP A: SPRUCE - PINE -FIR HEM -FIR 1 / # 2 ISTANDARD 112 STUD 3 STUD #3 STANDARD DOUGLAS FIR -LARCH SOUTHERN PINE 3 # 3 STUD STUD STANDARD STANDARD GROUP B HEM - FIR 1 & BTR I SOUTHERN PINE DOUGLAS FIR -LARCH 1 # 1 2 # 2 GABLE TRUSS DETAIL NOTES LIVE LOAD DEFLECTION CRITERIA IS L/240. PROVIDE UPLIFT CONNECTIONS FOR 105 PILE OVER CONTINUOUS BEARING (5 ESE TC DEAD LOAD). GABLE END SUPPORTS LOAD FROM 4' 0' UTLOOKERS WITH 2' 0' OVERHANG, OR 12' PLYWOOD OVERHANG, ATTACH EACH 'L' BRACE WITH 10cl NAILS. 0. 128'x3' min K FOR (1) 'L' BRACE SPACE NAILS AT 2' O.C. IN 18' END ZONES AND 4' O.C. BETWEEN ZONES. KXFOR ( 2) 'L' BRACES: SPACE NAILS AT 3' O.C. IN 18' END ZONES AND 6' O.C. BETWEEN ZONES. L' BRACING MUST BE A MINIMUM OF 80% OF WEB MEMBER LENGTH. GABLE VERTICAL PLATE SIZES REFER TO COMMON TRUSS DESIGN FOR PEAK, SPLICE, AND HEEL PLATES. VERTICAL LENGTH NO SPLICE LESS THAN 4' 0' 1X4 OR 2X3 GREATER THAN LESS THAN 4' 0', BUT 11' 6' 3X4 GREATER THAN 11' 6' 3.5X4 MAX. T T, LD, 60 PSF 8 Ill 8/ 2011 MAX, SPACING 24,0" REF ASCE7-05-GAB12015 DATE 1/1/09 DRWG A12015050109 RIGID SHEATHING REINME GABLE DETAIL FOR LET —IN VERTICALS GABLE TRUSS PLATE SIZES REFER TO APPROPRIATE ITW GABLE DETAIL FOR MINIMUM PLATE SIZES FOR VERTICAL STUDS, ERED TRUSS DESIGN FOR PEAK, HEEL PLATES. AL PLATES OVERLAP, USE A iAT COVERS THE TOTAL AREA OF I PLATES TO SPAN THE WEB. X4 2X4 2X8 YKUVIUL LUNNLI, I IUNJ 1-UK UYLItI JYLI. It ILU UN IHL LNUINLLKL I) IKUSS ULJIUN ATTACH EACH 'T' REINFORCING MEMBER WITH END DRIVEN NAILS: IOd COMMON (0.148'X 3.',M1N) NAILS AT 4' OC. PLUS 14) NAILS IN TOP AND BOTTOM CHORD. TOENAILED NAILS: 10d COMMON (0.148'x3',MIN) TOENAILS AT 4' O.C. PLUS 4) TOENAILS IN TOP AND BOTTOM CHORD, THIS DETAIL TO BE USED WITH THE APPROPRIATE ITW GABLE DETAIL FOR ASCE WIND LOAD. ASCE 7-98 GABLE DETAIL DRAWINGS A13015980109, A12015980109, A11015980109, A10015980109, A13030980109, A12030980109, A11030980109, A10030980109 ASCE 7-02 GABLE DETAIL DRAWINGS A13015020109, A12015020109, A11015020109, A10015020109, A14015020109, A13030020109, A12030020109, A11030020109, A10030020109, A14030020109 ASCE 7-05 GABLE DETAIL DRAWINGS A13015050109, A12015050109, A11015050109, A10015050109, A14015050109, A13030050109, A12030050109, A11030050109, A10030050109, A14030050109 SEE APPROPRIATE ITW GABLE DETAIL FOR MAXIMUM UNREINFORCED GABLE VERTICAL LENGTH.! T' REINFORCEMENT ATTACHMENT DETAIL T' REINFORCING 'T' REINFORCING MEMBER MEMBER TOENAIL - OR - JENDNAIL TO CONVERT FROM 'L' TO 'T' REINFORCING MEMBERS, MULTIPLY 'T' INCREASE BY LENGTH (BASED ON APPROPRIATE ITW GABLE DETAIL). MAXIMUM ALLOWABLE 'T' REINFORCED GABLE VERTICAL LENGTH IS 14' FROM TOP TO BOTTOM CHORD. EB LENGTH INCREASE W/ "T" BRACE WIND SPEED AND MRH T' REINF. MBR. SIZE T INCREASE 140 MPH 15 FT 2x4 10 2x6 50 140 MPH 30 FT 2x4 10 2x6 50 130 MPH 15 FT 2x4 10 2x6 50 130 MPH 30 FT 2x4 10 2x6 50 % 120 MPH 15 FT 2x4 10 % 2x6 50 X 120 MPH 30 FT 2x4 10 7. 2x6 40 7. 110 MPH 15 FT 2x4 10 2x6 40 X 110 MPH 30 FT 2x4 10 2x6 50 Z 100 MPH 15 FT 2x4 20 X 2x6 30 X 100 MPH 30 FT 2x4 10 % 2x6 40 Y. 90 MPH 15 FT 2x4 20 2x6 20 X 90 MPH 30 FT 2x4 20 2x6 30 X EXAMPLE ASCE WIND SPEED = 100 MPH MEAN ROOF HEIGHT = 30 FT, Kzt = 1.00 GABLE VERTICAL = 24' D.C. SP #3 T' REINFORCING MEMBER SIZE = 2X4 T' BRACE INCREASE (FROM ABOVE) = 10% = IAO 1) 2X4 'L' BRACE LENGTH = 6' 7" MAXIMUM 'T' REINFORCED GABLE VERTICAL LENGTH 1,10 x 6' 7' = 7' 3' Building Components Gmup Inc. Earth City, MO 63045 11=NGww READ AND FOLLOW ALL NOTES UN THIS SHEET! • an Tru require extre n fabricating, ha ntlling, shipping, installing and brnci Re, to followeBCSI (Building Component in Information, by TPI and WTCA) for saFety tices or to performing these functions. Installers shall provide temporary bracing per BC SI. leis .ted otherwise, top chord shall have properly attached structural panels and bottom ,.It have properly attached rigid ceiling. Locations shown for permanent lateral restraint webs V,all bracing installed per BCSI sections B3 6 B7. See this job's general notes page f more 'N'or INSTALLATION CONTRACTOR. r IMPORTANTC FURNISH COPY OF THIS DESIGN sheikshop not be responsible for any tlhand F tITWBuOanyComponentsGroupInc. truss conformance • design, any failure to build the truss in conFor mn ace with TPI, or fabricating, 0A ( mst a((ing 6 bracing of trusses. ]TWHCG connector plates are node of 20/".si i (W, 5 grade 37/40/60 (K/W/H,S) galy. steel. Apply plates to each face of truss, positioned b 9r nd on Joint Details. w• fAsealonthisdrawingorcoverpageIndicatesacceptanceandprofessionalengineeringre7solelyforthetrusscomponentdesignshown. The suitability pad use pf this component Fp building is the responsibility of the Building Designer per ANST/TPI I Sec. 2. ITW-BC& www.itwbcg.com; TPI: www.tpinst.com; WTCA www.sbcindustry.con; ]CC. ww..¢csafe.org r V • V i yamO [, y rr r rr• w.rorr• fjSg/ ' )pL8 ' 11 MAX TOT, LD. 60 PSF R E F LET —IN V E R T DATE 1/1/09 DRWG GBLLETIN0109 DUR, FAC. ANY MAX SPACING 24,0" 0 cc GE2 1 w m w --+ w m= o o i m L 2 C2 2 B 0' CEILING z z z z m U 2' 1'10"8 z' z' 2 C2 z' 0 2 o i in a'e" u2CEILING zGE 1 11' 22'8" up CUSTOMER: Owner Bldr JOB NAME: Wachsmuth Res. DATE: 10/27/2011 JOB NO.: 17474 MODEL: BUILDERS WARNING* THIS LAYOUT IS FOR PLRCEMENT OF ENGINEERED COMPONENTS. FOR ERECTION AND INSTALLATION CTEMPORRRY AND PERMANENT) FOLLOW INSTRUCTIONS ON BCSI-B1 SUMMARY SHEETS AND FINAL ENGINEERING SHEETS FOR EACH TRUSS. SEE FINRL'ENGINEERING SHEETS FOR NUMBER OF GIRDER PLIES, CONNECTIONS, WEB CONFIGURATIONS, BRACING, TRUSS SPACING RND REACTIONS. ALTERATIONS RND/OR REPRIRS TO TRUSSES MUST BE APPROVED IN RDVRNCE BY OUR ENGINEERING DEPARTMENT. BRCKCHRRGES WILL NOT BE ACCEPTED UNLESS OUR ENGINEERING DEPARTMENT RPPROVES THEM IN ADVANCE. ALL PLANS ARE NOT TO SCALE. DO NOT SCALE ANY PLANS, IF DIMENSIONS RRE MISSING OR ARE UNCLEAR, PLEASE CALL THE OFFICE TO GET THE DIMENSION. LORDING: 20+7+10 =37psf WIND SPEED: 120mph RSCE 7-05 Closed "B" SPACING: 24" DRAWN BY: Matthew PITCH: 0.25/12 OVERHANG: 16" CANT.: NR BEARING SIZE (s) : 8" SOURRE FT.: 680 WALL HE I GHT Cs) : 8 ' 0 " PLAT OF BOUNDARY SURVEY OFFICE for PERMIT zzECKHARDWACHSMUTH Legal Description Lots 19, 20, and 21, Block N9, BEL-AIR, according to the plat thereof as recorded in Plat Book 3, Page 79, of the Public Records of Seminole County, Florida. OG 5 1.05'- In 1.06'- 7 0 IN c on-r-Wi Q" c- -i7r, nn' O OiN) C S 89'58'18" E 125.00' 22 SURVEY NOTES: 1) The street address of the above -described property is 2030 Jefferson Avenue, 2) The above -described proparty lies in a Flood Zone X. rouro , , /.' woN RPC ( No n 0. W sooty a o.oe' .cn n m O z C W 0 z Q 4J J CCLn SURVEYOR' S CERTIFICATE This is to certify that I have made a Survey of the above described property and that the plat hereon delineated is an accurate representation of the same. I further certify that this Survey meets the Minimum Technical Standards set forth by the Florida Board of Land Surveyors pursuant to Section 427.027 of the Florida Statutes. REVISIONS: RESURVEYED ( NO CNANGE5)t 14 APRIL260 O 101 PROJECT NO: to - IZ i - 1\ 111•LI\ JVI\VL 111\U, 1JV1 .L R. BLAIR KITNER - P.L.S. NO:- 3382 Post Office Box 823, Sanford, F1. 32772-0823 40` 7) 322-20W SURVEY DATE: i j JANUARY ZQIQ CORRECT TO: Owner: Eckhard Wachsmuth 2030 Jefferson Avenue Sandford, Florida 32772 Phone: (407)619-4764 Engineer: C ED S 3IN5KiE 321-863-3223 M LMS. FLOR I DA =2754 RIO Drafting Service: Avenue2030 2772Saandfol"d i lu 3- - lefferson, SANFORD BUILDING DEPT. THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR PERMIT. A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER, OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE Or A. PERMIT PREVENT THE BUILDING DEPT FROM THEREAFTER REQUIRING A CORREC- TION OF ERRORS ON THE PLANS. CONSTRUCTION QR OTHER VIOLAT¢ONS OF THE CODES. Sheet List Sheet Number Sheet Name G-1 General Notes A-1 Floor Plan A-2 Front Elevation & Section A-3 Side & Rear Elevations S-1 Structural Plan S-2 Roof Framing Plan No. Description Date SCOPE OF WORK: CONCRETE NOTE: 1. FOOTINGS AND SLAB CONCRETE SHALL BE MINIMUM 3,000 P.S.I. AT 28 DAYS. 1. CONTRACTOR TO VERIFY EXISTING FOUNDATION FOOTER IS A MINIMUM 18" DEEP AND 16" WIDE. 2. DEMO EXISTING SLAB AS SHOW TO ALLOW FOR NEW FOOTER INSTALLATION. DEMO 6"x6" CONCRETE CURB. 3. CONSTRUCT 22'-0"x30'-0" WORKSHOP ADDITION ON EXISTING CONCRETE FOUNDATION. 4. ELECTRICAL AND MECHANICAL WORK BEYOND MINIMUM REQUIREMENTS IS NOT INCLUDED AS PART OF THESE CONSTRUCTION DOCUMENTS AND WILL BE COMPLETED UNDER SEPRATE PERMIT. GENERAL NOTES: 1. ALL WORK MUST COMPLY WITH CURRENTLY ADOPTED VERSIONS OF APPLICABLE CODES, INCLUDING, BUT NOT NECESSARILY LIMITED TO, THE FLORIDA BUILDING CODE 2007 w/ 2009 SUPPLEMENT, RESIDENTIAL, CHAPTER 3. SHOULD CONFLICTS ARISE BETWEEN ANY CODE REQUIREMENTS AND INFORMATION SHOWN ON THESE DRAWINGS, THE APPLICABLE CODE SHALL GOVERN. 2. TO THE BEST OF OUR KNOWLEDGE, THESE PLANS COMPLY WITH APPLICABLE BUILDING CODES. 3. AIA DOCUMENT A201, "THE GENERAL CONDITIONS OF THE CONTRACT FOR THE CONSTRUCTION OF BUILDINGS", SHALL BE CONSIDERED A PART OF THESE DOCUMENTS AND SHALL GOVERN ALL WORK OF THE CONTRACTOR AND SUBCONTRACTOR. 4. DIFFERING SITE CONDITIONS; CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. IF A DIMENSIONAL ERROR OCCURS OR A CONDITION NOT COVERED IN THE DRAWINGS IS ENCOUNTERED, CONTRACTOR SHALL NOTIFY THE ENGINEER BEFORE COMMENCING WITH THAT PORTION OF THE WORK. 2. BATCH, TRANSPORT, PLACE, AND CURE ALL CONCRETE ACCORDING TO THE AMERICAN CONCRETE INSTITUTE, LATEST ADDITION AND THE FLORIDA BUILDING CODE. 3. ALL REINFORCING STEEL SHALL BE DESIGNED, FABRICATED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE AND THE MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES. ALL REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM 615-74. WELDING WIRE FABRIC SHALL CONFORM TO ASTM A-185. 4. ALL SLABS ON GRADE SHALL BE 4" THICK AND REINFORCED WITH FIBERCRETE UNLESS OTHERWISE NOTED. MOISTURE BARRIER BENEATH FLOOR SLABS SHALL BE 6 MIL VISQUEEN. REBARS NOTES: 1. ALL DETAILING AND ACCESSORIES SHALL CONFORM TO TYPICAL DETAILS SHOWN IN THE "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES ACI 315, LATEST EDITION". 2. ALL CONTINUOUS VERTICAL OR HORIZONTAL BARS IN FOOTINGS, FOUNDATION WALLS, SLABS AND OTHER CONCRETE SHALL BE LAP -SPLICED WHERE NECESSARY OR DESIRABLE, BY WIRING TOGETHER IN CONTACT. LENGTH OF ALL LAPS SHALL BE 36-BAR DIAMETERS OR 25" MINIMUM, WHICHEVER IS GREATER. DESIGN LOADS: 1. ASSUMED DESIGN LOADS ARE AS FOLLOWS: A. WIND LOADS (FBC-2007): B. FLOOR LIVE LOADS: C. FLOOR DEAD LOADS: D. ROOF LIVE LOADS: E. ROOF DEAD LOADS: F BASIS FOR DESIGN: 2. A - INDICATES TRIBUTARY AREA a - INDICATES END ZONE WIDTH (FT.) 120 MPH SPEED 1.0 IMPORTANCE FACTOR EXPOSURE B PRESSURE COEF. = t0.18 40 PSF. 15 PSF. 20 PSF. 7 PSF. ENCLOSED V - INDICATES WIND VELOCITY I - INDICATES IMPORTANCE FACTOR 3. GROSS PRESSURES SHALL BE LINEARLY INTERPOLATED FOR (A) SHOWN IN TABLE. 4. GROSS PRESSURES ARE FOR COMPONENTS & CLADDING. 5. POSITIVE PRESSURES INDICATE FORCES ACTING TOWARD TO PROJECTED SURFACE. NEGATIVE PRESSURES INDICATE FORCES ACTING AWAY FROM THE PROJECTED SURFACE. 6. ROOF ZONES - 1, 2, & 3, (INCLUDES OVERHANG ZONES 1, 2, & 3) 7. WALL ZONES - 4 & 5 8. PRESSURES ARE BASED ON ASCE 7-02 CRITERIA 3. ALL REINFORCING STEEL SHALL BE DESIGNED, FABRICATED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE BUILDING CODE 9. NET DESIGN ROOF PRESSURES SHALL BE CALCULATED USING THE GROSS WIND REQUIREMENTS FOR REINFORCED CONCRETE STRUCTURES. ALL REINFORCING PRESSURES LESS THE SELF WEIGHT OF THE MATERIALS (DEAD LOAD). HOWEVER, STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615-A706/A706M- THE APPLIED DEAD LOADS SHALL NOT EXCEED 5 PSF FOR ROOF OF STRUCTURE. 01, GRADE 40, FY = 40,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185-01. 4. MINIMUM CONCRETE COVERAGE OF STEEL TO BE 3" CLEAR AT BOTTOM OF FOOTINGS; 1/2" CLEAR AT OUTSIDE OF WALLS, 3/4" CLEAR AT INSIDE OF WALLS. 5. CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BRACING, SHORING, GUYING OR OTHER MEANS TO AVOID EXCESSIVE WOOD NOTES (ROOF): STRESSES AND TO HOLD STRUCTURAL ELEMENTS IN PLACE DURING 1. ALL WOOD FRAMING SHALL BE FABRICATED AND INSTALLED AS PER AITC, CONSTRUCTION. TPI AND NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION. 6. TYPICAL DETAILS APPLY, WHETHER SPECIFICALLY REFERRED TO 2. ALL WOOD STRUCTURAL MEMBERS SHALL BE CONTROLLED STRESS GRADE OR NOT IN THE DRAWINGS AND SPECIFICATIONS. LUMBER HAVING A FIBER STRESS OF AT LEAST 1,200 PSI. 7. ANY DEVIATIONS FROM THESE GENERAL NOTES, OR FROM THE MATERIALS, SPECIFICATIONS, AND TECHNIQUES INDICATED ON THE PLANS, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, AND SHALL BE VERIFIED BY THE ENGINEER AS ACCEPTABLE TO THE BUILDING OFFICIAL HAVING JURISDICTION BEFORE EXECUTION. 10. WALLS IN AREAS SUBJECT TO MOISTURE, INCLUDING TUB - SHOWERS AND STALL SHOWERS SHALL BE PROTECTED BY MOISTURE RESISTANT, MATERIALS TO A MINIMUM HEIGHT OF 70" ABOVE FINISHED FLOOR (70" ABOVE DRAIN OPENING AT SHOWERS OR TUB WITH SHOWER) 3. ALL WOOD MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE AND MASONRY SHALL BE TREATED. TRUSS NOTES: 1. PREFABRICATED ROOF TRUSSES SHALL BE DESIGNED BY THE MANUFACTURED IN ACCORDANCE WITH THE DESIGN SPECIFICATION FOR METAL PLATE CONNECTED WOOD TRUSSES, TP1-78, BY THE TRUSS PLATE INSTITUTE, FOR THE SPAN AND CONDITIONS SPECIFIED. SHOP DRAWINGS AND SPECIFICATIONS, BEARING THE SEAL OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA, SHALL BE SUBMITTED FOR REVIEW AND TRANSMITTAL TO THE BUILDING DEPARTMENT -FOR APPROVAL. FOR BASIC PLANS PROVIDE TRUSS ENGINEERING ATTACHED TO PLAN. 11. PROVIDE ADEQUATE VENTILATION IN ATTIC SPACE. WHEN 50% OF THE VENT AREA IS PROVIDED AT UPPER ROOF LEVELS THAT IS MORE 2. PRE-ENGINEERED TRUSSES SHALL BE DESIGNED FOR 125 MPH WIND LOAD THAN 3'-0" ABOVE THE LOWER VENTS (E.G. RIDGE VENTS), VENT AS PER FLORIDA BUILDING CODE AND GRAVITY LOADS AS LISTED BELOW, AREA MUST BE AT LEAST 1/300 NET OF THE AREA OF THE VENTED UNLESS NOTED OTHERWISE. SPACE; WHERE HIGH-LEVEL VENTING IS NOT PROVIDED, TOTAL VENT AREA MUST BE AT LEAST 1/150 NET OF THE AREA OF THE VENTED TOP CHORD LIVE AND DEAD LOAD: = 35 PSF SPACE. BOTTOM CHORD DEAD LOAD: = 10 PSF 45 PSF 12. PROVIDE 22" X 30" MINIMUM ACCESS TO EACH ATTIC SPACE WITH 30" OF HEAD ROOM. ACCESS CLOSURE SHALL BE WEATHER- 3. ROOF FRAMING AND COMPONENTS, AS SHOWN OR THAT MAY BE REQUIRED STRIPPED AND INSULATED TO THE "R" VALUE OF THE SURROUNDING SHALL BE DESIGNED TO ACT AS SHEAR DIAPHRAGM. ALSO ADEQUATE CEILING AREA.. BRACING BE PROVIDED BETWEEN THE TRUSSES FOR THE DIAPHRAGM ACTION. BRACE ALL TRUSSES BOTH DURING CONSTRUCTION AND PERMANENTLY. 13. SEE SITE PLAN BY OTHERS FOR BUILDING LOCATION, BUILDING SETBACKS, EASEMENTS, AND TOPOGRAPHICAL ELEVATIONS. 14. ALL SOFFITS AND FASCIAS SHALL HAVE A MINIMUM DESIGN PRESSURE OF +33/-43 PSF, AS DETERMINED BY THE AAMA 1402-86 TEST STANDARD. UNSUPPORTED SOFFIT LENGTHS SHALL NOT EXCEED THE MAXIMUM DIMENSIONS OF THE TESTED CONFIGURATION, AS REPORTED BY THE MANUFACTURER. SOFFITS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURERS RECOMMENDATIONS FOR HIGH WIND REGIONS. 4. FOR TRUSS DESIGN, UPLIFT CALCULATIONS AND THE FINAL TRUSS PLANS, SEE STRUCTURAL SHOP DRAWINGS SUPPLIED BY THE TRUSS MANUFACTURER. TIE DOWN SCHEDULE WILL BE PROVIDED BASED ON UPLIFT CALCULATIONS SUPPLIED BY THE TRUSS ENGINEER. DECKING NOTES: 1. PREFABRICATED ROOF TRUSSES SHALL BE SHEATHED WITH PLYWOOD, O.S.B. OR THERMO-PLY INSULATED SHEATHING, EXCEPT IN DESIGNATED ALTERNATE BRACED PANELS PER FLORIDA BUILDING CODE 2007 RESIDENTIAL WHERE PLYWOOD IS SPECIFIED BY THE CODE. LAY SHEATHING WITH LONG DIMENSIONS PERPENDICULAR TO TRUSSES AND NAILED TO ROOF TRUSSES AT 4" O.C. AT EDGES AND 6" O.C. FIELD WITH 8D COMMON NAILS. PROVIDE BLOCKING OR HURRICANE CLIPS AT HORIZONTAL JOINTS AND STAGGER ENDS. ZONE I ZONE ZONE I ZONE ZONE 1 2 3 4 5 PSF) (PSF) (PSF) (PSF) (PSF) TRIBUTARY LOCATION AREA SF) PE 47515 z A <_ 10 F 27.03 27.03 27.03 30.78 30 78 cn Sttir.s e: MAIN 44.29 51.80 51.80 48.05 59.31 321-863-3223 BUILDING ENTERPRISES LLC a=3.5 FT V=130 MPH 2 A >_ 100 F 23.27 36.78 23.27 4429 23.27 44.29 24.15 41.42fi46.05 2415 arts. 4aiORMt D A3275ANkl3}. b FiCiro tJAt,tr3{ 1=1.0 SealA>_500Fz 23.7 23.7 23.27 19.5219.52 36.78 44.29 30.78 36.78 36.78 No. Description Date Addition for Wachsmuth Residence 2030 Jefferson Avenue Sandford, Florida 32772 General Notes Project number 11-0422 Date 8/20/11 G _ Drawn by J. Kelley Checked by E. Shinkskie Scale 1 : 1 Door Schedule 22' - 0" 1 5'- 9 1/2" 1 5'- 2 1/2" 1 14' - 4" 8'- 4" 1 n Floor Plan 1 /4" = 1'-0" Design Pressure p (Pso Door Positive Negative Pressure Mark Count Family and Type Width Height Pressure Zone 4 Zone 5 D1 2 Single -Flush: 36" x 80" T - 0" 6' - 8" 22.6 -24.6 -26.5 1 Double -Glass 1: 60" x 80" 5'- 0" 6' - 8" 21.9 -23.8 1 -27.9 Window Schedule Rough Opening Design Pressure p (Pso Positive Negative Pressure Count Family and Type Width Height Pressure Zone 4 Zone 5 4 Single Hung Fin: 3640 3' - 5 1/2" 3' - 11 1/2" 23.4 -25.4 -31.0 02 41 OO.C22 WALL TO BE REMOVED 04 22 OO.W8 8" CMU WALL W/ (1) #5 IN FILLED CELL @ 6'-0" O.C. MAX (24" MIM LAP) No. Er) '4E thSKlr.: 32-863.3223 LLC 7 Wiu>Ttkirr tn. 3RSMr itt?q,iim 27i4 PE 47515 Seal Date Addition for Wachsmuth Residence 2030 Jefferson Avenue Sandford, Florida 32772 Floor Plan Project number 11-0422 Date 8/20/11 Drawn by J. Kelley Checked by E. Shinkskie ED SmxsK.i:r.. cra G v v i = 3 321-863-3223 ENTERPtRiSES,LLC as MiNO f C)fl DA 417, 4 Seal No. Description Date Checked on for Wachsmuth Residence 2030 Jefferson Avenue Sandford, Florida 32772 Elevation & Section er 11-0422 8/20/11 A-2 J. Kelley E. Shinkskie Scale As indicated 04 22 OO.W8 8" CMU WALL W/ (1) #5 IN FILLED CELL @ 6-0" O.C. MAX (24" MIM LAP) 107 46 10.A1 I FIBER CEMENT SIDING LJ yRight Elevation 1 /4" = 1'-0" n Rear Elevation L 1 /4" = 1'-0" P 7 Ell smNSKIr 3.21-863-3223 Y ENTERPRISES, LC jj 4707 It 91 U Tog f Pu,J. 4t3t{ F CN'W:F a i t 7q: t Sea No. Description Date Addition for Wachsmuth Residence 2030 Jefferson Avenue Sandford, Florida 32772 Side & Rear Elevations I< Project number 11-0422 Date 8/20/11 n _ 3DrawnbyJ. Kelley / l Checked by E. Shinkskie Scale 1/4" = 1'-0" LVL to CMU Connection 0 0 c 0 N 22'-0" a m[.-_.- a—.-- •------®-----aI I------------------ -------IIOO. C44 I 02 41 I lei I I I I I IO2 41 OO.C44 I IO2 20 07.3 II I I I I I I lei EXISTING CONCRETE SLAB DESIGNED BY OTHERS. CONTRACT TO VERIFY MINIMUM FOOTER SIZE PRIOR TO CONSTRUCTION DEMO HATCH SECTION AND INSTALL 16"x16" FOOTER w/ (2) #5 BARS CONTINUOUS EPDXY # 5 REBAR 8" INTO EXISTING FOOTER @16" O.C. EPDXY ( 2) #5 REBAR 8" INTO EXISTING FOOTER DEMO HATCH SECTION AND INSTALL 16"x16" FOOTER w/ (2) #5 BARS CONTINUOUS 2'- 0" 1 18'-0" I lei I I II I I I I I I I' I I I le I 2'- 0" Existing Foundation = 22' - 0" Foundation Foundation Plan 1 / 4" = 1'-0" Keynote Legend 02 20 07.1 EXISTING ROOF TO REMAIN IN PLACE 02 20 07.3 EXISTING FOUNDATION 02 20 08.30 EXISTING CMU WALL 02 41 OO.C44 EXISTING CONCRETE CURB TO BE REMOVED AND GROUND FLUSH WITH EXISTING SLAB 06 05 23.MT18 SIMPSON MTS18 TWIST STRAP AT EACH TRUSS BEARING POINT 06 11 OO.D11 2x4 FRAMING SPIKED TO TRUSSES WITH 8d NAILS @ 8" O.C. STAGGARED 06 18 OO.131 LVL WOOD BEAM. SEE TRUSS MFG SHOP DRAWINGS FOR SIZE. 0 0 M u c 0c 0 U- c U) X W T y Ell SHINISKIE P 515 g 321-863-3223 ENTERPRISES, LLC 3 tii.l4r rcelaira,+ d7f... Seal No. Description Date Addition for Wachsmuth Residence 2030 Jefferson Avenue Sandford, Florida 32772 Structural Plan Project number 11-0422 Date 8/20/11 C _ 1 Drawn by J. Kelley V Checked by E. Shinkskie Scale As indicated URoof Framing 1 /4" = V-0" ED SHINSK1[. 321-863-3223 ENTERPRISES,LLCiLC J 4r 1V LO 1:D e kui e E Seal No. Description Date Addition for Wachsmuth Residence 2030 Jefferson Avenue Sandford, Florida 32772 Roof Framing Plan Project number 11-0422 Date 8/20/11 C _2 Drawn by J. Kelley V Checked by E. Shinkskie Scale 1/4" = V-0"