Loading...
HomeMy WebLinkAbout804 Orange Ave 14-1151; HOME REHABMAR Q 6 2014 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: ' C Documented Construction Value: $ 51,926 Job Address: 804 Orange Sanford, Florida 32771 Historic District: Yes No Parcel ID: Parcel: 25-19-30-5A G-100E-0030 Zoning: Description of Work: Rehab of exsiting home per Seminole county scope of work. Plan Review Contact Person. Keith Owens Title: VP of Operations Phone: 407-388-5820 Fax: 866-674-1239 E-mail: kowens@blackstreetenterprises.com Property Owner Information Name Dinah Wright Phone: 407-430-8711 Street: 804 Orange Ave. Resident of property? : Yes City, State Zip: Sanford, Florida 32771 Contractor Information Name Blackstreet Enterprises Phone: 407-388-5820 Street: 13245 Daniels Landing Circle Fax: 866-674-1239 City, State Zip: Winter Garden, Florida 34787 State License No.: CGC-1509119 Architect/Engineer Information Name: N/A Phone: Street: Fax: City, St, Zip: E-mail; Bonding Company: N/A Address: Mortgage Lender: Address: PERMIT INFORMATION Building Permit 12 Square Footage: 1680 Construction Type: SFR No. of Dwelling Units: Flood Zone: N/A Electrical New Service — No. of AMPS: Mechanical 0 (Duct layout required for new systems) Plumbing No. of Stories: 1 New Construction - No. of Fixtures: Fire Sprinkler/Alarm No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 71.3. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Qp 1 ature of Own%' 422X ge ' n Date Signature of Contractor/Agent Date SignatuteofNota - fa Date E W E?T 1'; Commis ion # DD 996983 a My'6annmission Expires Ferr• June 01 , 2014 Owner/Agent i Personally Known to Me or Produced ID Type of ID "DL APPROVA S: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Keith Owens Print Si ate 0%,111"„4".INA gar ru°. s Corn fission EWETT t DD 996983 My C mi ion Expires I{ j°,r•'•• June f. I,, ", m,a• 1, 2014 Contractor/Agent is Personally Known to .Me or Produced ID yne of ID WASTE WATER: BUILDING: Rev 11.08 APR 0 2 2014 CITY OF SANFORD Y BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: i' 5 1 Documented Construction Value: $ 51,926 Job Address: 804 Orange Sanford, Florida 32771 Historic District: Yes No Parcel ID: Parcel: 25-19-30-5A G-100E-0030 Zoning: Description of Work: Rehab of exsiting home per Seminole county scope of work. Plan Review Contact Person: Keith Owens Title: VP of Operations Phone: 407-388-5820 Fax: 866-674-1239 E-mail: kowens@blackstreetenterprises.com Property Owner Information Name Dinah Wright Phone: 407-430-8711 Street: 804 Orange Ave. Resident of property? : Yes City, State Zip: Sanford, Florida 32771 Contractor Information Name Blackstreet Enterprises LLC. DBA BSE /Const. Group Phone: 407-388-5820 Street: 13245 Daniels Landing Circle Fax: 866-674-1239 City, State Zip: Winter Garden, Florida 34787 State License No.: CGC-1509119 Architect/Engineer Information Name: N/A Street: City, St, Zip: Bonding Company: N/A Address: Building Permit 12 Phone: Fax: E-mail: Mortgage Lender: Address: PERMIT INFORMATION Square Footage: 1680 Construction Type: SFR No. of Stories: 1 No. of Dwelling Units: Flood Zone: ?C 5 EE i C Ei Electrical A- / Plumbing New Service — No. of AMPS: New Construction - No. of Fixtures: Mechanical uct layout required for new systems) Fire Sprinkler/Alarm 13 No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, beaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. c Signature of Owner gen Date Sigature of Contractor/Agent Date r vi C'L S C Blac treet Enterp es - Keith Owens tmt ner/Agent's 14ame Il t Print Co actor/Agent's Na A Date T NI A JEWETTommisionMDD996983 Mycnmmission Expires June 01 . 2014 Owner/Agent t Personally Known to Me or Produced ID Type of ID TDL APPROVA S: ZONING- TILITIES: _ 41 1r4 ENGINEERING: FIRE: COMMENTS: Rev 11.08 jlsNp EWETTComsronDD996eS3 MY mi sion E. June 1, 2014 Contractor/Agent is Personally Known to Me or Produced ID —Ave of ID WASTE WATER: BUILDING: — •2— / `/ MAR 2 6 2014 CITY OF SANFORD B_ U_ ILDING & FIRE PREVENTION PERMIT APPLICATION Application No: { y —' \ Documented Construction Value: $ '31 a lc 3 7Z 1 Job Address:Historic District: Yes No; -- Parcel ID: lC, `3 0 . S !fit {, - to a p — o a' 3 o Zoning: Description of Work: G S?Qc k&,oJ, r o l4? -, )cs.41n4— hncS Plan Review Contact Person: C) -f-KI Title: Phone: Fax: G.G-?N Qrl!i E-mail:%aweH5 Property Owner Information Name en &In t 0 c=, Slick Phone: ti ° 7 . Jt1 l c — 4 • 11 Street: S 14 css Awt c r t c- Resident of property? : C S City, State Zip: Ca- '3;k---r-? l Contractor Information Name C-'L 71 ".4 / Phone: Street: City, State Zip: Fax: State License No.: Architect/Engineer Information Name: Ly [iN— Phone: Street: City, St, Zip: Bonding Company: lv A — Address: Building Permit Square Footage: No. of Dwelling Units: Electrical New Service — No. of AMPS: Fax: E-mail: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: Flood Zone: No. of Stories: Plumbing ®``7 7c—k .Jc.•-r <<Hd5 New Construction - No. of Fixtures: Mechanical 0 (Duct layout required for new systems) Fire Sprinkler/Alarm 0 No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Signature of Owner/Agent Date Signature of Contractor/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID _ APPROVALS: ZONING: UTILITIES: ENGINEERING: COMMENTS: Ili VOX cev, 0.,1 c wS Print Contractor/Agent's Name Signature of Notary -State of Florida Date Contractor/Agent is Personally Known to Me or Produced ID Type of ID WASTE WATER: BUILDING: Rev 11.08 THIS INSTRIJMENT PREPARED BY: Name: Keith Owens Address: 13245 Daniel.,; Landing Circle Winter Gatd rri'--.'- NOTICE OF COMMENCEMENT Permit Number: I /1 i 15 Parcel ID Number: 25-19-30-5A G-100E-0030 MRRVANW M)R',. SAIMCE UII.INTY I; l,l•;M Or MR11111 (,'(ItIRT & (;UMGTHOL11114 BH 0828;3 Pq 00831 (1 pq) CLERK' S ## 2014032939 Ftf (; tll(l)Fn 03PFifiX014 12.6;25 PM R01INI) ING R'lF3 10.00 R11- 111- tOH) 13y T Saith The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) LEG LOT 3 BLK 10 TR E TOWN OF SANFORD PB 1 PG 56 2. GENERAL DESCRIPTION OF IMPROVEMENT: Rehab of exsiting home to include new flooring, windows, painting & plumbing. 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: Dinah Wright 804 Orange Ave Sanford, Florida 32771 Interest in property: Rnmpnwnpr Fee Simple Title Holder (if other than owner listed above) Name: 4. CONTRACTOR: Name: Blackstreet Enterprises Phone Number: 772-3 4A?Qa1PY ~ I,n,'aRYF II , P- No Address: 535 NW Mercantile Place #107 Port St. Lucie, Florida 34986 Ct Of ni` 5. SURETY (If applicable, a copy of the payment bond is attached): cMINOL`t. Name: N/A Phone Number: Address: 6. LENDER: Name: N/A Address: Phone Number: 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name: Keith Owens Phone Number: 407-388-5820 Address: 13245 Daniels Landing Circle Winter Garden, Florida 34787 8. In addition to himself or herself, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number of person or entity designated by owner: 9. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true tot e',best gf m knowle an belief. Signature Owner ofLessee, or O efs or Le ee's (Print Name -and Provide ignatorys Title/Office) Authorized Officer/Director/Partner/Manager) State of FLofu a, County of pa/\M itiC2i The foregoing instrument was acknowledged before me this 7-44' nA day of w' _ NAt V 20 G by e &0sL Git-a A0,AA, - Who is personally known to me Name of person making state nt OR who has produced identification W type of identifi C,* FT a4I i NINA JEWETT ni Commission 8 DD 996983 2My Commission Expires June 01, 2014 IV CIS CONTRACTOR SERVICES AGREEMENT HOME PROGRAM RESIDENTIAL REHABILITATION 804 ORANGE AVENUE, SANFORD, FLORIDA 32771 CC-9000-13/AMM) THIS AGREEMENT is made and entered into this hAday of January , 20 14 , by and between BLACK STREET ENTERPRISES, LLC, duly authorized to conduct business in the State of Florida, whose address is 535 NW Mercantile Place, Unit 107, Port Saint Lucie, Florida 34986, hereinafter referred to as "CONTRACTOR", and SEMINOLE COUNTY, a political subdivision of the State of Florida, whose address is Seminole County Services Building, 1101 East First Street, Sanford, Florida 32771, hereinafter referred to as "COUNTY". WITNESSETH: WHEREAS, COUNTY desires to retain the professional residential Rehabilitation services of a competent and qualified contractor to provide for an identified HOME funded residential Rehabilitation project benefitting an income -qualified household in Seminole County; and WHEREAS, COUNTY has allocated funds from its currently available HOME Program funding allocation from the United States Department of Housing and Urban Development HUD") for completion of the Project herein described; and WHEREAS, COUNTY has requested and received competitive proposals for the retention of residential Rehabilitation services from qualified contractors; and WHEREAS, CONTRACTOR has been deemed competent and qualified to furnish contractor services to COUNTY and desires to provide professional services according to the terms and conditions stated herein, NOW, THEREFORE, in consideration of the mutual understandings and covenants set forth herein, COUNTY and CONTRACTOR agree as follows: HOME Program Residential Rehabilitation 804 Orange Avenue, Sanford, Florida 32771 CC-9000-13/AMM) Page 1 of 27 CERTIFIED COPY MARYANNE MORSE CLERK OF CIRCUIT COURT SEM OLE COUNTY, FLORIDA BY DEPUTY CLERK Section 1. Incorporation of Recitals. The above recitals are true and form a material part of the mutual understandings upon which the Parties have relied in entering into this Agreement. Section 2. Definitions. a) "CFR" means the Code of Federal Regulations. b) "Contract Documents" shall mean the documents and forms attached as the several Exhibits to this Agreement, the terms and conditions of which shall be complied with as part of the required Project services rendered. 1) The Contract Documents shall comprise the entire agreement between the Parties; are an integral part of this Agreement, incorporated herein by reference and shall specifically include the following: Exhibit A - This Agreement, including the Scope of Services attached as Exhibit A; Exhibit B - Bid Form; Exhibit C — Seminole County Rehabilitation Standards Exhibit D - EPA's Lead Based Paint Renovation, Repair and Painting Program; and 2) As the Project progresses, additional documents shall become part of this Agreement between COUNTY and CONTRACTOR. These documents are: A) Performance Bond; B) Payment Bond; C) Material and Workmanship Bond; D) Specifications; E) Technical Specifications provided in the Contract Documents; HOME Program Residential Rehabilitation 804 Orange Avenue, Sanford, Florida 32771 CC-9000-13/AMW Page 2 of 27 F) General Conditions; G) Supplementary Conditions, including any utility -specific forms provided by the applicable utility service provider; H) Notice to Proceed; 1) Change Orders; J) Certificate of Substantial Completion; K) Certificate of Final Inspection; L) Certificate of Engineer; M) Certificate of Final Completion; N) CONTRACTOR's Release; 0) Drawings and Plans; P) Supplemental Agreements; Q) CONTRACTOR's Waiver of Lien (Partial); R) CONTRACTOR's Waiver of Lien (Final and Complete); S) SubcontractorNendor's Waiver of Lien (Final and Complete); T) Consent of Surety to Final Payment; IT) Instructions to Bidders; and V) CONTRACTOR's Insurance Requirements, Certificate and Insurance Policies. c) There are no Contract Documents other than those listed above in this Section. The Contract Documents may only be altered, amended or repealed by a modification as provided in the General Conditions. HOME Program Residential Rehabilitation 804 Orange Avenue, Sanford, Florida 32771 CC-9000-13/AMM) Page 3 of 27 d) "CS Director" means the Community Services Director or his/her designee within COUNTY's Community Services Department. e) "COUNTY Approval" means written approval by the CS Director or the Board of County Commissioners as may be necessary from time to time. f) "HOME" or "HOME Program" shall mean the federally funded, affordable housing program authorized by 42 USC, Sections 12701, et seq. and administered by HUD pursuant to Title 24, CFR Part 92, and comprising the sole funding source for the Project through COUNTY. g) "HUD" shall mean the United States Department of Housing and Urban Development. h) "Parties" shall mean CONTRACTOR and COUNTY with respect to this Agreement. i) "Property" shall mean the real property parcel located at 804 Orange Avenue, Sanford, Florida 32771 and bearing parcel identification number 25-19-30-5AG-100E-0030. 0) "Rehabilitation" / "Project" shall mean the renovation of the existing residential structure on the Property and site work in a manner complaint with all applicable State and local building, fire and health codes, all as more specifically described in the Exhibits A and B. The terms Project and Rehabilitation are sometimes used interchangeably herein. k) "USC" means United States Code. Section 3. Services. COUNTY does hereby retain CONTRACTOR to furnish professional Rehabilitation services and perform those tasks as further described in and in accordance with the Contract Documents. CONTRACTOR shall also be bound by all requirements as contained in this Agreement, the attendant Contract Documents, bid solicitation package and any addenda thereto. HOME Program Residential Rehabilitation 804 Orange Avenue, Sanford, Florida 32771 CC-9000-13/AMM) Page 4 of 27 Required services shall be specifically enumerated, described and depicted in the Notice to Proceed authorizing performance of the Rehabilitation Project. This Agreement standing alone does not authorize the commencement of any work in the absence of the appropriate Notice to Proceed nor does it require COUNTY to issue any Notice to Proceed. Section 4. Term. This Agreement shall take effect on the date of its execution by COUNTY and shall run for a period of one (1) year, provided, however, that the Project must be completed and have obtained a certificate of occupancy from the Building Official by no later than ninety (90) days from issuance of a Notice to Proceed for the Project (sixty (60) days to substantial completion and an additional thirty (30) days to final completion). CONTRACTOR's failure to meet that deadline shall be a material breach of this Agreement. Expiration of the term of this Agreement shall have no effect upon a Notice to Proceed issued pursuant to this Agreement and prior to the expiration date. Obligations entered therein by both Parties shall remain in effect until completion of the work authorized by the Notice to Proceed. The foregoing notwithstanding, Sections 10, 111 14, 20 and 21 shall survive for their respective purposes and to comply with the public records retention requirements. Section 5. Authorization for Services. Authorization for performance of professional services by CONTRACTOR under this Agreement shall be in the form of a written Notice to Proceed issued and executed by COUNTY and signed by CONTRACTOR. Said Notice to Proceed shall describe the Project services required, state the dates for commencement and completion of work, and establish the amount and method of payment. The Notice to Proceed will be issued under and shall incorporate the terms of this Agreement. Section 6. Time for Completion and Liquidated Damages. The services to be rendered by CONTRACTOR shall be commenced as specified in the Notice to Proceed to be issued HOME Program Residential Rehabilitation 804 Orange Avenue, Sanford, Florida 32771 CC-9000-13/AMM) Page 5 of 27 hereunder and shall be completed within the time specified therein. It is agreed that in the event the Rehabilitation Project assignment is not completed within the specified time frame, CONTRACTOR shall pay COUNTY, as liquidated damages and not as a penalty, TWO HUNDRED FIFTY AND, N0/100 DOLLARS ($250.00) for each day of delay beyond the originally scheduled completion date. Section 7. Compensation. COUNTY agrees to compensate CONTRACTOR for the professional services called for under this Agreement a Fixed Fee in the amount of FIFTY-ONE THOUSAND NINE HUNDRED TWENTY-SIX AND N01100 DOLLARS ($51,926.00). CONTRACTOR shall perform all work required by the Scope of Services, but in no event shall CONTRACTOR be paid more than the negotiated Fixed Fee amount stated above. CONTRACTOR shall be compensated based on prices listed on the Bid Form attached as Exhibit B. Upon review and approval of CONTRACTOR's invoice, COUNTY shall, in accordance with the terms as set forth in Chapter 218, Part VII, Florida Statutes, pay CONTRACTOR the approved amount, subject in all respects to the provisions of Sections 8 and 9 of this Agreement. Section 8. Retainage. All authorized Project services shall be governed by the retainage provisions herein. If COUNTY determines that work is substantially complete and the amount retained is considered to be in excess, COUNTY may, at its sole and absolute discretion, release the retainage or any portion thereof. In order to assure timely, full and satisfactory performance under this Agreement, COUNTY shall withhold a retainage from CONTRACTOR's periodic requests for payment according to the following schedule: a) Until fifty percent (50%) of completion of the Project, as documented by CONTRACTOR's submission of monthly reports, in comparison to the construction timetable HOME Program Residential Rehabilitation 804 Orange Avenue, Sanford, Florida 32771 CC-9000-13JAMM) Page 6 of 27 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: 12-18-2013 I hereby name and appoint: an agent of: Keith Owens Rite Angle Plumbing Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The specific permit and application for work located at: Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: Rite Angle Plumbing State License Number: CFC 1427530 Signature of License Holder: STATE OF FLORIDA COUNTY OF Seminole 12-18-2014 The foregoing instrument was acknowledged before me this day of 1 C . , 20013 , by r,a - L-U l c, who is personally known to me or who has produced =FL.`-Da2 I . Lim . as identification and who did (did not) take an oath. Signature Notary Seal) BOBBIE BLACKWELL MY COMMISSION # EE044409 EXPIRES November 22, 2014 207ta8.0153 FlOndallotaryService.com Rev. 08.12) Print or type name Notary Public - State of Commission No. My Commission Expires: t1or 22 2011 LIMITED POWER O A T FORNEY Altamonte Springs, Cassellaerry, U lke Mary, l,ongg ood, Saetford, Seminole Cou ly, Winter St itt1, Date: 9 23-201 I hcreb\ name and appoint: 1"'cith Owifw; l laclatrccl. I:nterl,risc.s U.C. Sul a.;cnt c,L _ _-- _-- to he my lawful io ;icl li)r nue to ilppl; IOr. rcccipt II-ir. skin tier and dig all thim's. ncccSSary to this appointuicnt for (c•hcch. oui.N' One Option): D The specific permit and <fpplicitloll t(w '."ol-l; located at: Expiration Fate For Fhis Linliied I.iccnse I loldcr Nanle: I,iorlcl 11)unbar SLOW IJCCIL>C fVllillbel-: ii l atun: of Licrn e I lal lrr: ' S I :A H OF I-TORID A alha {3re2r it1 inslrt.tlent c,t rtc(a,a lti•rf eC beto.•c° [lie a tlethisz_: of o-4L6by / , i (,t,.. % 5 a hc is persalial ly known to ins- Or tdwhoIris produced r—LLt C_.; --- — as identiticatloll and hu did fdid nut) AI1 Math. SI2naturc Print or tYpc nanlc — c . Vly COMMISSION # EE044409 s1 0 EXPIRES November 22, 2014 e i ... C15:: Florad&T:otaYService.corn J cn.1i3.I21 Nouir\ Public - State III' _ C oninliision No. kly C olllmissioji Fxpilvs — I e vtc! 1c,},nRor,,a Property Record Card Parcel: 25-19-30-SAG-100E-0030 Owner: WRIGHT DINAHB SFtcnini0l EuN1v; ra.LiOq Property Address: 804 ORANGE AVE SANFORD, FL 32771 Back < Previous Parcel FNew Search Parcel: 25-19-30-5AG-100E-0030 Value Summary Property Address: 804 ORANGE AVE Owner. WRIGHT DINAH B M ailing: 804 ORANGE AVE SANFORD, FL 32771 - 2155 Subdivision Name: SANFORD TOWN OF Tax District: S1-SANFORD Exemptions: 00-HOMEST EAD (1994) DOR Use Code: 01-SINGLE FAMILY Map Aerial FB.thl Footprint + Extents Center Larger Map Advanced Map Dual Map View - External Legal Description LEG LOT 3 BLK 10 TR E TOWN OF SANFORD PB 1 PG 56 Tax Details 2014 Working 2013 Certif ied Values Values Valuation Cost/ Market Cost/Market Method Number of 1 1 Buildings Depreciated Bldg 60,459 56,930 Value Depreciated EXFT Value Land Value 9, 968 9,968 Market) Land Value Ag Just/ Market 70, 427 66,898 Value Portability Adj Save Our Homes 3,253 717 Adj Amendment 1 Adj Assessed Value 67,174 66,181 Tax Amount without SOH: $529 2013 Tax Bill Amount $523 Tax Estimator Save Our Homes Savings: $6 Does NOT INCLUDE Non Ad Valorem Assessments Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 67,174 67,174 0 Schools 67,174 25,000 42,174 City Sanford 67,174 42,174 25,000 SJWM( SaintJohns Water Management) 67,174 42,174 25,000 County Bondsl 67,1741 42,174 25,000 Sales I Deed[ Datel Bookl Paged Amounts Vac/Imp1 Qualified) Land Methodi Frontagel Depth Units Unit Price Land Value FRONT FOOT & DEPTH 64 117 000 175.001 9,968 Building Information Description Year Built Fixtures Base Total Living Ext Wall Adj Repl Appendages Actual/ Effective Area SF SF Value Value I SINGLE 1973 5 1,305.00 1,680.00 1,503.00 CONC 60,459 76,531 i FAMILY BLOCK Description$ Area cnudum,.., 77 SOW 804 Orange Ave - Building Permit.xlsx SOW FORM (revised 12-11-13) Rehabilitation at 804 Orange Ave. Sanford EXTERIOR Patch and repair all wall penetrations to prevent potential moisture infiltration. Include surface prep, bonding agents and finish to match existing. Foam sealants may only be applied as a substrate for masonry type products in openings of 4 inches or less. Painted 1 epandable foam will not be acceptable as a finish product. Remove sidewalk finishes to provide a suitable, non slip concrete finish. Texture coat 2 with acrylic pool deck finish colored to match existing. +/-100 SF Pressure clean and re -paint complete exterior, including inside walls of carport. +/-1700 3 SF 4 Remove all debris from attic space INTERIOR / DOORS / WINDOWS / DRYWALL / PAINT / TRIM Interior drywall and paint touch up is required in most rooms due to faded/mismatched 5 colors on walls and ceilings. Several coats may be needed to provide a neutral wall finish. Include patch and paint in all living areas, interior of laundry room, carport for complete 6 new interior finish. +/- 1406 SF 7 Replace all interior doors to all rooms closets, bedrooms etc. 8 Replace patio sliding doors with new. Include vertical blinds on interior of opening. Furnish and install new single hung, tinted, Low E windows sized to fit existing openings. 9 White finish. KITCHEN / CABINETS / COUNTERTOPS Venthood is beyond it's useful life and should be replaced with a newer model. Provide 10 proper clearances from cooktop to underside of unit. Furnish and install new double bowl sink at kitchen. Coordinate with new countertops and 11 kitchen cabinets. Remove and replace kitchen cabinets and countertops with new materials. Include 12 laminate top PLUMBING SYSTEM Remove and replace water heater with new 40 gal, energy star model. Include drain pan 13 and proper connections Replace existing water supply piping with new materials such as CPVC or pex pipe. 14 Include all new water supply fixtures and valves, sinks, water heater and toilets. 15 Vanity cabinets are outdated and may be replaced with new vanity cabinets with tops. 16 Replace all sinks and faucets with newer lever action models. Dryer vent duct behind unit is crushed and needs to be replaced. Provide dryer vent cover 17 on exterior HVAC SYSTEM Complete new system needs to be installed. Include new distribution ducts, minimum 15 SEER heat pump model sized per Manual J calculations. Include designed layout for new duct system for supply and return air distribution. Include compensation for new window, new exhaust fans, new electrical and cutting / patching of drywall to facilitate installation 18 and a 7 day programmable thermostat ELECTRICAL SYSTEM Replace existing electrical panel and branch circuit wiring with a newer, more reliable 19 system per NEC. Include new smoke detectors, GFI devices, receptacles, switches etc.. 20 Provide two pods for delivery and storage of homeowner belongings. Install new ceramic tile to laundry room floor, repair drywall ceiling and texture, paint 21 throughout walls and ceiling. Install drywall in garage/room conversion area to walls, repair ceilings as needed and 22 texture walls and ceiling, install new closet door,new carpet and paint throughout. 23 Install multi lock removable security cage over new A/C condensor 24 Secure all light fixtures to structure properly. CC-9000-13/AMM - HOME Program Residential Rehabilitation at 804 Orange Ave Sanford, FL 32771 Home Program Residential Rehab - 804 Orange Ave Exterior Dimensions Opening Location MO Width MO Height Construction Type Notes 1 Living Room 106" 50" Block Double Configuration w/ Mull 2 Enclosed Carport Front 50" 49" Wood 3 Enclosed Carport Right 50" 36" Wood 4 Laundry 37" 38" Block 5 Kitchen 35" 36" Block 6 Dining 72" 82" Block Sliding Glass Door 7 Hall Bath 37" 26" Block Obscure Glass 8 Bedroom 1 Right 37" 39" Block 9 Bedroom 1 Rear 37" 38" Block 10 Bedroom 2 Rear 37" 38" Block 11 Bedroom 2 Left 37" 38" Block 12 Bedroom 3 53" 38" Block 13 Master Bath 36" 25" Block Obscure Glass 14 Master Bedroom Right 37" 39" Block 15 Master Bedroom Front 53" 38" Block 16 11 12 Side B 13 14 Side C 10 15 Side A 804 Orange Ave. Parcel ID 25-19-30-SAG-100E-0030 Side D Florida Departmentof BCIS Home Log In User Registration Hot Topics I Submit Surcharge Stats & Facts Busines Professi nal Product Approval a.!a USER: Public User Regulation b osvt t(o l tAewm oavi e' osPR{o1HIs10N5°,co" Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL12968-R1 Application Type Revision Code Version 2007 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Corrurussion if necessary. Comments Archived Product Manufacturer General Aluminum Company Address/Phone/Email 1001 W. Crosby Rd. Carrollton, TX 75006 972) 242-5271 Ext 207 ivan.paredes@gactx.com Authorized Signature Ivan Paredes ivan.paredes@gactx.com Technical Representative Ivan Paredes Address/Phone/Email 1001 W. Crosby RD. Carrollton, TX 75006 Ivan. paredes@gactx. com Quality Assurance Representative Ted Scroback Address/Phone/Email 1001 W. Crosby RD Carrollton, TX 75056 ted.scroback@gactx.com Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard AAMA/WDMA/CSA 101/I.S.2/A440 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 11/02/2011 Date Validated 12/08/2011 Date Pending FBC Approval Date Approved 12/13/2011 Year 2005 Summary of Products C rL s rrooey numDer or name uescnpiion 12968.1 Series 1100 Alurinum S/H (Fin) 54" x 72" Annealed 3/16" Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL12968 R1 C CAC 02 Series 1100 (54 x 72) APC.odf Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 08/11/2013 Design Pressure: +40/-40 Installation Instructions Other: Units to be glazed per ASTM E1300-04. FL12968 RI II 02 08-00576A Rectanoular.odf FL12968 RI II 02 08-00577A Designer.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL12968 R1 AE 511035.pdf Created by Independent Third Party: Yes 12968.2 Series 1450 Aluminum S/H (Flange) 54" x 72" Annealed 3/16" Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL12968 R1 C CAC 04 Series 1450 (54 x 72) APC.pdf Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 08/12/2013 Design Pressure: +40/-40 Installation Instructions Other: Units to be glazed per ASTM E1300-04. FL12968 RI II 04 08-00632A Rectanoular.pdf FL12968 R1 II 04 08-00633A Desyner.odf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL12968 R1 AE 511037.odf Created by Independent Third Party: Yes 12968.3 Series 1550/1570 Aluminum S/H (Flange) 54" x 72" Insulated Annealed DSB Limits o Certification Agency Certificate Approved for use in HVHZ: No FL12968 R1 C CAC 01 Series 1550-1570 (54 x 72) APC.odf Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 08/12/2013 Design Pressure: +40/-40 Installation Instructions Other: Units to be glazed per ASTM E1300-04. FL12968 R1 II O1 08-00574A Rectanoular.odf FL12968 R1 II O1 08-00575A Desianer.odf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL12968 R1 AE 511034.odf Created by Independent Third Party: Yes 12968.4 Series 1900/1970 Aluminum S/H (Fin) 54" x 72" Insulated Annealed DSB Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL12968 R1 C CAC 03 Series 1900-1970 (54 x 72) APC.odf Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 08/11/2013 Design Pressure: +40/-40 Installation Instructions Other: Units to be glazed per ASTM E1300-04. FL12968 R1 II 03 08-00578A Rectanoular.odf FL12968 R1 II 03 08-00579A Desianer.odf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL12968 R1 AE 511036.odf Created by Independent Third Party: Yes 12968.5 Series 2700 Aluminum S/H (Fin) 48" x 72" Insulated Annealed DSB Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL12968 R1 C CAC CERT2700SINGLE.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/20/2015 Design Pressure: +40/-40 Installation Instructions Other: Units to be glazed per ASTM E1300-04. FL12968 R1 II 08-00815A.odf FL12968 R1 II 08-00816A.odf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL12968 RI AE 511360.odf Created by Independent Third Party: Yes 12968.6 Series 2700 Twin Aluminum S/H (Fin) 88 5/8" x 72" Insulated Annealed DSB Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL12968 R1 C CAC CERT2700TWIN.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/24/2015 Design Pressure: +40/-40 Installation Instructions Other: Units to be glazed per ASTM E1300-04. FL12968 R1 1I 08-00817A.odf FL12968 R1 II 08-00818A.odf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports CI 17DG4 D1 AC r11 Zr1 nAF FOR ANCHOR SPACING SEE NOTES 1I0`AANNDD 11 Number of anchors for units usino 3116"ITW Ta DCOn Unit w idth (In) Height (in) 26 50 'e" 30.60 3Z:00'`" 54 00 !''' Total Lowerl Upper Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb 26.0 13.0 2 2 3 2 3 2 3 2 4 2 38i43 19.2 2 3 3 3 3 3 3 3 4 3L1`12. 25.3; 2 3 3 3 3 3 3 3 4 3 545ry'°27.3 2 4 3 4 3 4 3 4 4 4 Z2.0>, 36.0. 1 2 4 3 4 3 4 3 4 4 4 Design pressures for units glazed with IGU 3/32" annealed Unit width (in) Height 19.1 26.5 30.5 37.0 54.0 in) Pos Neg Pos Neg Pos Neg Pos Neg Pos Neg 26.0 40.0 60.0 40.0 60.0 40.0 60.0 40.0 60.0 40.0 60.0 38.4 40.0 60.0 40.0 60.0 40.0 60.0 40.0 60.0 40.0 53.3 50.6 40.0 60.0 40.0 60.0 40.0 60.0 40.0 60.0 40.0 49.5 54.6 40.0 60.0 40.0 60.0 40.0 60.0 40.0 60.0 40.0 47.0 72.0 40.0 1 60.0 40.0 1 60.0 1 40.0 60.0 40.0 60.0 40.0 40.0 Design pressures for units glazed with IGU 1/8" annealed Unit width (in) Height 19.1 26.5 30.5 37.0 54.0 In) Pos Neg Pos Neg Pos Neg Pos Neg Pbs Neg 26.0 40.0 60.0 40.0 60.0 40.0 60.0 40.0 60.0 40.0 60.0 38.4 40.0 60.0 40.0 60.0 40.0 60.0 40.0 60.0 40.0 60.0 50.6 40.0 60.0 40.0 60.0 40.0 60.0 40.0 60.0 40.0 49.3 54.6 40.0 60.0 40.0 60.0 40.0 60.0 40.0 60.0 40.0 47.0 72.0 40O 0 60O 0 40.0 60O 0 40.0 1 60.0 40.0 1 50.0 40.0 40.0 54" MAX. WIDTH{ A B 72" MAX. HEIGHT A Iyrw.rrrim VIEWED FROM EXTERIOR DESIGN PRESSURE RATING IMPACT RATING t40PSF NONE REVISIONS DESCRIPTION DATE I APPROVED UPDATED PER NEW TESTING 08/26/09 1 R.L. GENERAL NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF FLORIDA BUILDING CODE. 2) OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. OPENING DESIGN IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON THIS PRODUCT IN WIND BORNE DEBRIS REGIONS 4) SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". SHIM WHERE SPACE IS 1/16" OR GREATER OCCURS. 5) WINDOW FRAME MATERIAL TO BE ALUMINUM ALLOY 5063-T5 .054" THICK. WINDOW SASH MATERIAL TO BE ALUMINUM ALLOY 6063-T5 .070" THICK. 6) USE CAULK BEHIND WINDOW FLANGE AT HEAD, JAMBS AND SILL. 7) USE CAULK FOR PERIMETER SEAL AROUND EXTERIOR OF WINDOW FLANGE. 8) GLASS THICKNESS MAY VARY PER THE REQUIREMENT OF ASTM E1300 GLASS CHARTS. 9) WHERE THE WATER RESISTANCE TEST REQUIREMENT OF 15% OF DESIGN LOAD APPLIES, POSITIVE DESIGN LOADS WILL BE LIMITED TO 40PSF DUE TO WATER TEST PRESSURE OF 6.0 PSF ACHIEVED IN TEST. 10) INSTALL FLANGE FRAME WINDOW WITH 3/16" DIAMETER TAPCON OF SUFFICIENT LENGTH TO ACHIEVE MIN. 1-1/4" EMBEDMENT INTO SUBSTRATE WITH 2 5/8" MINIMUM EDGE DISTANCE. FOR HEAD INSTALLATION LOCATE ANCHORS 6" MAX. FROM CORNERS. SPACING MUST NOT EXCEED 14". FOR JAMBS INSTALLATION LOCATE ANCHORS 6" MAX. FROM CORNERS. SPACING MUST NOT EXCEED 20". 11) IF EXACT WINDOW SIZE IS NOT LISTED IN ANCHOR CHART. USE ANCHOR QUANTITY LISTED WITH NEXT LARGER SIZE FOR THE APPROPRIATE DESIGN PRESSURE REQUIRED. 12) INSTALL RIGID FILLER AT EACH ANCHOR LOCATION. 13) ALLOWABLE STRESS INCREASE OF 113 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 14) INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIAL WITH THE FOLLOWING PROPERTIES: A. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. B. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). GENERAL ALUMINUM COMPANY 1001 W. CROSBY RD. CARROLLTON TEXAS 75006 SERIES 1550/1570 RECTANGULAR SH NON IMPACT 54" X 72" ELEVATION, CHARTS AND GENERAL NOTES IRAWN: I DWG NO. I RE' F.A. 1 08-00574 SCALE NTS JDATE 1 0/08/08 - SHEET 1 OF 2 J\\J\S tR I IL 0 o O; STATOF •: ONA i INSTALLATION ANCHOR CONCRETE/MASONRY BY OTHERSONEBYWOOD BUCK BY OTHERS CAULK BETWEEN WINDOW Q Q FLANGE & WOOD BUCK J CAULK BETWEEN WOOD BUCK & MASONRY OPENING BY OTHERS 1 1/4" MIN. REVISIONS DESCRIPTION DATE I APPROVED UPDATED PER NEW TESTING 08/26/09 IR.L. PERIMETER CAULK — WNDOW WIDTH ONE BY WOOD BY OTHERS 1/4" MAX. BUCK BY OTHERS SHIM SPACE FLANGE TYPE t/a" MAX. SHIM SPACEWINDOWFRAMERIGIDFILLER 1 1/4" MIN. EMBEDMENT HEADER GLAZING TYP. FLANGE TYPE WINDOW FRAME SEE SHEET TYP. INTERIOR JAMB a INSTALLATION SEE SHEET 1 ANCHOR EXTERIOR INTERIOR CAULK BETWEEN WINDOW 6 Q MASONRYOPENING HEIGHT EXTERIOR RIGID FILLER BY OTHERS puCAULKBETWEENWINDOWFLANGE & WOOD BUCK CONCRETEMASONRY BY OTHERS PERIMETER CAULK BY OTHERS n SECTION B—B FLANGE TYPE WINDOW FRAME SILL PERIMETER CAULK BY OTHERS SILL STOOL BY OTHERS a 4 CAULK BETWEEN WINDOW FLANGE PRE CAST SILL WITH VULKEM PRE CAST SILL 116 ADHESIVE CAULK OR BY OTHERS APPROVED EQUAL SECTION A —A GENERALoo Lw.MINURo eM Ro OMPANY \\`\\\\S 1 I Co CARROLLTON TEXAS 75006 ,•NOENSF S% SERIES 1550/ 1570 RECTANGULAR SH NON IMPACT 0„6951 54" X 72" ( — INSTALLATION DETAILS OO,. TAT OF • \ DRAWN: DWC NO. REV F.A. Dare 08 500574 A ONA 1Ea NTS 10/08/08 2 OF 2 Validator / Operations Administrator) General Aluminum Corporation P.O. Box 819022 Dallas, TX 75381 Attn: Ivan Paredes AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION I - m7_ MA The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based on successful completion of tests, and the reporting to the Administrator of the results of tests, accompanied by related drawings, by an AAMA Accredited Laboratory. 1. The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATION RECORD OF PRODUCT TESTEDAAMA/WDMA/CSA 101/I.S.2/A440-05 H-R40-1372x1829(54x72) COMPANY AND PLANT LOCATION CODE SERIES MODEL & PRODUCT MAXIMUM SIZE TESTED NO. DESCRIPTION General Aluminum Corporation FRAME SASH 1001 W. Crosby Rd. GA-1 1450/1550/1570 SH 1372 mm x 1829 mm 1349 mm x 924 mm Carrollton, TX 75006 AL)(O/X)(OG)(ASTM) 4'6" x 6'0") 4'5" x 3'0") 2. This Certification will expire August 12, 2013 and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3. Product Tested and Reported by: Construction Consulting Laboratory, International Report No.: 09-159 Date of Report: August 25, 2009 Date: August 27, 2009 Cc: AAMA JGS ACP-04 (Rev.8/06) Validated for Certification h' 4;t_ A oci ted Laboratories, Inc. Authorized for Certification Americ4AFchtte ctural Manu actu Association L. Roberto Lomas P.E. 1432 Woodford Rd. Lewisville, NC 27023 336-945-9695 rllomas@lrlomaspe.com Manufacturer: General Aluminum 1001 W. Crosby RD. Carrolton, TX 75006 Engineering Evaluation Report Product Line: Series 1550/1570 Aluminum SH Window — Non -Impact Report No.: 511034 Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Community Affairs for Statewide Acceptance per Rule 9N-3. The product listed herein complies with requirements of Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-00574 revision A, titled Series 1550/1570 Rectangular SH — Non - Impact and drawing number 08-00575 revision A, titled Series 1550/1570 Designer SH — Non -Impact, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Test report No.: CCLI-09-159 signed by Wesley Wilson Construction Consulting Laboratory International, Carrollton, TX AAMAMDMA/CSA 101/I.S.2/A440-05 Design pressure: ±40.Opsf Water penetration resistance: 6.Opsf. 3. Anchor calculations, report number 511034-1 B and comparative analysis report number 511034-2B, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: Maximum design pressure: ±40.Opsf Maximum unit size: 54" x 72" Units must be glazed per ASTM E 1300-04. This product is not rated to be used in the HVHZ. This product is not impact resistant and requires impact protection in wind borne debris regions. Frame material to be Aluminum 6063-T5 Installation: Units must be installed in accordance with approval document, 08-00574 revision A and 08-00575 revision A. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). 0 4-TAY 4F SF 0RI4P.G\.\ s 0NAL1E0 1 of 1 Luis R. Lomas, P.E. FL No.: 62514 11 /30/2011 gStla DepartmPn BCIS Home Log In User Registration Hot Topics j Submit Surcharge Stats & Facts Publications FBC Staff I BCIS Site Map Links Search ines* USER: professiIProduct Approval Public User Regulation Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL12274 _ Application Type New Code Version 2007 Application Status Approved Corrrrlents Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products General Aluminum Company 1001 W. Crosby Rd. Carrollton, TX 75006 972) 242-5271 Ext 207 ivan.paredes@gactx.com Ivan Paredes ivan.paredes@gactx.com Ivan Paredes 1001 W. Crosby RD. Carrollton, TX 75006 ivan.paredes@gactx.com Ted Scroback 1001 W. Crosby RD Carrollton, TX 75056 ted.scroback@gactx.com Exterior Doors Sliding Exterior Door Assemblies Certification Mark or Listing American Architectural Manufacturers Association Steven M. Urich, PE 4 Validation Checklist - Hardcopy Received Standard AAMA/WDMA/CSA 101/I.S.2/A440-05 Method 1 Option A 03/04/2009 03/04/2009 03/09/2009 04/07/2009 Year 2005 Model, Number or Name Description 12274.1 Series 420 Aluminum SGD XX and XO (Finless) 96" x 80" Single Glass and Insulatea I enperea. Per Manutacturers installation instructions. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL12274 RO C CAC 01 Series 420 XX (96 x 80) APC.Ddf Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 06/30/2012 Design Pressure: +40/-40 Installation Instructions Other: See attached drawings for the installation instructions, FL12274 RO II 01 FL00498 Drawina.Ddf product performance, limits/DP and other lircats of use. Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 12274.2 Series 420 Aluminum SGD XX and XO (Finless) 96" x 96" Single Glass and Insulated Tempered. Per Manufacturer's installation instructions. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL12274 RO C CAC 02 Series 420 XX (96 x 96) APC.Ddf Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 06/30/2012 Design Pressure: +40/-40 Installation Instructions Other: See attached drawings for the installation instructions, FL12274 RO II 02 FL00499 Drawino.Ddf product performance, lirnits/DP and other limits of use. Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 12274.3 Series 420 Alurrrinum SGD OXO (Finless) 146" x 80" Single Glass and Insulated Tempered. Per Manufacturer's installation instructions. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL12274 RO C CAC 03 Series 420 OXO (146 x 801 APC.Ddf Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 07/02/2012 Design Pressure: +40/-40 Installation Instructions Other: See attached drawings for the installation instructions, FL12274 RO II 03 FL00500 Drawina.Ddf product performance, limits/DP and other limits of use. Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 12274.4 Series 420 Aluminum SGD OXO (Finless) 146" x 96" Single Glass and Insulated Tempered. Per Manufacturer's installation instructions. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL12274 RO C CAC 04 Series 420 OXO (146 x 96) APC.Ddf Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 07/02/2012 Design Pressure: +40/-40 Installation Instructions Other: See attached drawings for the installation instructions, FL12274 RO II 04 FL00501 Drawing.odf product perforrrence, lirnits/DP and other hints of use. Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 12274.5 Series 430 Aluminum SGD XXX (Finless) 143" x 80" Single Glass and Insulated Tempered. Per Manufacturer's installation instructions. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL12274 RO C CAC 05 Series 430 XXX (143 x 80) APC.Ddf Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 07/02/2012 Design Pressure: +40/-40 Installation Instructions Other: See attached drawings for the installation instructions, FL12274 RO II 05 FL00502 DrawinD.Ddf product performance, limits/DP and other limits of use. Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 12274.6 Series 430 Aluminum SGD XXX (Finless) 143" x 96" Single Glass and Insulated Tempered. Per Manufacturer's installation instructions. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL12274 RO C CAC 06 Series 430 XXX (143 x 96) APC.Ddf Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 07/02/2012 Design Pressure: +40/-40 Installation Instructions Other: See attached drawings for the installation instructions, FL12274 RO II 06 FL00503 Drawino.Ddf product performance, limits/DP and other limits of use. Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: back Next MOASONERr : ON OTHERS CAULK p TWF"EN WOOD BUCK WSONRY OPENING BY OTHERS. CONCRCTE OR MASONRY IN llON ANCHOR OVLOn CRS MIN Iwo x DOCK BY OTHERSHERS ENi a SRA CE PERIMETER-/ A GAOTH BY / OTHERSA% SHIM M J/ FINLESSTVPEFRAME HEADER 1gI M SPACE EXTERIOR INTERIOR s GLAZING iVP. SEE SHEET 2 III ryI- DEC' FITILESSRAM TYPE FINLE55 TVPC FRAMF. FRAME SILL 1 JAMB 1 — N EMBEDMENt 1 — a \ u EMI CDMENiON E BY WOOD BUCK BY OTHERS CONCRETE OR J \ MASONRY OPENING l BY OTHERS `CAULK BETWEEN DOOR SILL s CONCRETEIN' wLKEM- 16 ADHESIVE CAULK OR I// Il SEC TON A— A APPROVED EQUAL EDGE Nr RAI HOTS ER" Ij MC PRODUCT S+OAN HERHN IS DESIGNED AND uANUlICnRED TO COUPLY w,TH ME O DISTANCE 2) OPENING TOBE DESIGNED AND ANCHORID TO PROPERLY REANSER ALL LADRIX+S 10SrRURECHA CECD. 3) ODURNG MPAACTCRESSiAN CM EW FfO HH R ON THIS P ftOWCT iN AREAS R 7I Y a) EACOH INSTAU. nTION C OR .11I D Of G SHIM. ASIMUu I15OAt/15 DST N E1/1'. IM WHERE SPACE GREATER OCCURS. S) A wADOOR RA MMT RA LKTO OC AL MIN u ALL., PARAR SEPARATOR r 67 Np DOORAHNLCSSHEAD AN JA185. SI . MUST BE ATTACHED TO 11E SUBSTRATE 1— ITH wLKEM 116 AGIfSIVC CAULK DR APPROVED EQUAL. T) USC CAULK FOR PERIMETER SEAL AROJND IIR:RIOR OF DOOR. 3/16 TAPCON J R. B) GLA55 M MAY VA M R TTIREMCNT OF AST 1 ARI PPLIS. 9) WHERE TIERESISTANCE WIFEMENI OF ISDESIGNLOADAPPLIESwnrERmssWREPOSTLDELIMITEDIaAOPSFDUCTOwA2RTESTPRCSSUREOFEIPSFACHIEVEDOGISr` O10) INSTALL HNLES5 FRAME DOOR vAIH RIO SCREW OF SUFF NT LENCRE TO ACiIEVE MIN. 1-1/]' CFROM CONCRETE J EMBEDMENT INTO SUBSRATE. LOCATE ANCHORS G' MAx CORNERS AND 19 NAN. O.C. REAP TER FOR HEADY ArvO JAues. OR MASONRY 1/ OPENING SHIM SPACE II) INSTALL n AUC ODOR Wi I.3/Ifi DIAMETER TAP HCIENI LENGRE 10 EMREOMENT B9 BY OTHERS KIN-1 / a INTO SURSTRATE. LOCALE ANCHORS 6-MP%. FROM CORNERS AND NA%. O.C. MERAFTER FOR HEAD AND JAMBS r21 MC 1/1 STRUCTURE WCREASC IS NOT USED IN THIS PRODUtr. 1}) INSTALLATION AN CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUESTRATE MATFRIAI. RIIES: Nu SPECIFIC GRAVITY OF 1- 0,12 DESIGN PflESSURE flAT1AG MPACT RATING B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3.200 PSI. To TYRE I ATER). 340PSF IMORE C. MASONRY - STRENGTH CONFOFMANCE ASTM C-90. GRADE N. (OR a N TERIOR EXTERIOR PERIMETER BY OTNERI SEC11ON 6- 8 HHA GRACE I.- I ELEVATION AEWFO FROM EXTERIOR OP MA SONRY NG OPNI BVEOTHERS CAULK BETWEEN WOODBUCKITSONRY OPENING BY OTHERS. I INSTALLATION ANCHOR TWODy W000 BUCK BY OTHERSDiybEy svn by Luis R. LOR P.E. Locatlm: tA32ywomoro Rd. Lexavilk. RIC 27023 kte: 2008.00. 0418:03:51 - 05'OD By OTHERS IANCHCHOOLPTION R BUCKT BY OTHERS-/ PERIMETERCAULKBYoTHeas FINLE$$ TYPEFRAMETIRE EXTERIOR GLAZING — EE SHEET 1 FINLESS — FRAME SILL CACBE—EN — RUCKIsONRvOPENINGBY OTHERS. I "'" CONCRETE OR SOY 0EIINR OPENIGI /2 MIN. BY OTHERS DOOR WTUTH CONMTE OR Rv ASEOry OPENINGsl/i° vncr INTERIOR IUA E sHl SPACBYOTHERS f I/ 9" M A% J SHIM SPACE e I I CAULK HE— EN wOOD ONRY BUCKkBY SOTtERSPENININTERIORDooR HEIE 9Z INNTALLATION ANCHOR EXTERIORFINLESS TYPE PERIMETER 1-I/]' MIN. FRAME JAMB " CAULK OTHERS TWO SY WOOD BUCK RY OTHERS EMBEDMENT SECTION B- B a' IN fMd. C BY BUCK CHNBY OTHERSCONCRETEIXtJ - ° dUCH MA%. DOIXt WDM 9fi MA NRY OTHERS pY OTHERSCAULKBETWEEN DOOR SILL HGR= r A SEE NOTES11CONCRETE WITH VIILNEM 2 ;/2 ID nND tl I RO EVE CAULK OR SECTION A -AAPPROVEDEQUALEDISTAN1ANCE DOoaAracIGHTy 10N B El SEPAR" 1 T/,BIAPCoN A ELEVATION CONCRETE VIEWED FROM EXTERIOR OR MASONRY ° OPENING By tERs SHIM1 - GENERAL ALUMINUM COMPANY oEsl'cN PREssuRe Ranr o MPAcrn.nne 140PSF NGr+E r Validator / Operations Administrator) General Aluminum Corporation P.O. Box 819022 Dallas, TX 75381 Attn: Ivan Paredes AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based on successful completion of tests, and the reporting to the Administrator of the results of tests, accompanied by related drawings, by an AAMA Accredited Laboratory. 1. The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATION RECORD OF PRODUCT TESTEDAAMAIWDMA/CSA 101/I.S.2/A440-05 SD-R40-2438x2032 (96x80) CODE SERIES MODEL & PRODUCT COMPANY AND PLANT LOCATION MAXIMUM SIZE TESTED NO. DESCRIPTION General Aluminum Corporation FRAME PANEL 1001 W. Crosby Rd. GA-1 420 SGD AL XX C G)(ASTM) 2438 mm x 2032 mm 1232 mm x 2007 mm Carrollton, TX 75006 8'0" x 6'8") 4'1" x 67') 2. This Certification will expire June 30, 2012 and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3. Product Tested and Reported by: Construction Consulting Laboratory, International Report No.: 08-165 Date of Report: February 4, 2009 Date: February 18, 2009 Cc: AAMA JGS ACP-04 (Rev. 8/06) Validated for Certification h' 4W A4ocidLaboratories, Inc. Authorized for Certification 7; Ameri 4h--rcte`'c{ual Ma`nt fact-ure Association mwo a a o 10 v Parcel lDZ5-|V-3O-SAC-lUOEfN3O F1 omnms ~' TR ~'` /\ IOX6[/ D m* a 7`-u D 6 side 14 IM 3 TR r---^ 15 NOTE: TR:'TRANSFER REGISTERS |NEACH BEDROOM AHU:- J.STONS AIR HANDLER |NCLOSET WITH 5KVVHEAT ONDEN6ER:'Z.STON HEAT PUMP 15SEER CONDENSER 1DXI4FILTER BACK RETURN GRILL UNDER PLATFORM Street Address u ..r 804 Oran e Aveg Sanford FL 32771 y Latitude, Lon girtude .; 29.14620,-81.0534° r a a s House Square Foota.- eg s I503-sq ft f i' Nar Dinah B Wright F: ....... .... ...... N' . f i : a Phone: 407-844 9179 i Email o. SH R 75 Number of residents 2 Ceiling height 9 Waif-U-value R-value 0.09 11 Floor U-value I R-value 0.2 15 Cei I i n g U va'I ue` R-value Q0333` 30 Window U-value 1 Window SHGF V 0i 6 Moisture grains 58 z Duct loss % 10 Duct gain % 10 Cooking infiltraction (ACH)' 0;`6 Heating infiltration (ACH) 0.8 Winter ventilation 0' Summer ventilation 0 Indoor Heating Cooling 7 ...................................... ............... . ........ . ... ... . ........... .. ... ....................... .................... .......... . ....... ......... . ...... .......... . ............. . .... ........ . ............ ...... . ......... 4"1Indbor temperature F) 70 75 A ............ ................. .......................................... - ..................................................................................... ................... .......... ............. . ... .............. I Design temperature difference(OF) 33 15 Windows 7095 26.2 Heating Loads 27,051 BTU/hr I Ceiling I . System Efficiency Loss Windows Wall Floor J \ Infiltration 3 4: Area Btuh % of load_ Wafl 1$94 6.2 Ceiling 2002 7 8'.' Windows 9749 37.9 Sensible Infiltration 2076 8 1 z x Latent Infiltration 4962 19.3 System Efficiency.,Gain 2038 7 9 , Internal 2400 9 3 Sensible People Load .4,60: 1 Latent People Load. 460 1 r8r' r Tota"f K 25741 i u.,. w._:... ......... Serisible .Load a 20h9 Latent load 5422 q.. iiIry SH R 0.79 R ........ Capacity at 75- SHR 2.26 Tons Cooling Loads 25,741 BTU/hr 3 Sensible People Load Latent People Load Wall AED Graph 15000 -- I 10000 — — 0 5000 8am 9am loam 11am 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm Hourly Loads — Average Winter Outdoor Winter Indoor`' 370F 70°F Sensible Cooling 20,319 Btuh Latent Cooling 5,4 22Btuh'f i Required Cooling Airflow 924 CFM Sensible Heating ; 27,051Btuh F Required Heating Airflow 351 CFM All calculations are based rovedupona hvac industry standards and procedures, and comply with all local, P pp ti"Y state and federal coderequirements. All computed results are Estimates. Product provided by Energy Design Systems and Idea Tree f fff y i APR 14 2014CITY OF SANFORD s. BUILDING & FIRE PREVENTION T ----- -- PERMIT APPLICATION Application No: 1 _ , Documented Construction Value: $_ QL ciNo p Job Address: `d Ol.f OKA-0 VC-_- A-t1 Historic District: Yes NoX Parcel ID: Zoning: Description of Work: 26TOP 14&-- fVyA 9 wsmu_ Corr - Plan Review Contact Person: Title: Phone: Fax: E-mail: Property Owner Information Name Phone: Street: City, State Zip: Resident of property? : Contractor Information Name = Cnr)( , (;-- P0Phone: UO % J Street: _3; 1 qxu-snf C, S Fax: t f City, State Zip: (X ( .a n &.C) E ( 3 835 State License No.: A spsbO 4 p'/ Name: Street: City, St, Zip: Bonding Company: Address: Building Permit Square Footage: _ No. of Dwelling Units: Electrical Architect/ Engineer Information Phone: Fax: E- mail: _ Mortgage Lender: Address: PERMIT INFORMATION Construction Type: No. of Stories: Flood Zone: Plumbing New Service - No. of AMPS: New Construction - No. of Fixtures: Mechanical N ( Duct layout required for new ysterns) Fire Sprinkler/Alarm 0 No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID j Ll_ Signatur o gent Date Print Contractor/Agent is Produced ID yi4 lifla`lj Public - StatelfFlorida My Comm. Expires Jan 16, 2018 Commission N FF 071760 Elonded Through National Notary Assn. Personally Known to Me or Type of ID F L. 7 L" APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: COMMENTS: FIRE: BUILDING: Rev 11.08 CKSTEE'' Et4jrp tpRISIES, LLC SUBCONTRACT 1NSTRUCTIO1*1S DATE: CONTRACTOR: Black Street Enterprises, LLC JOB: 804 Orange Ave, Sanford FL, 32771 TRADE:. HVAC SUBCONTRACTOR: ABCool Heating & Air A3TENII:ON: Mannie Wooten mentoned project. Congratulations on being awarded this subcontract for the above se instructions st p byVclosed the step: subcontract. documents and ask that you please read carefully and fol1. .AttachedaretheSubcontractAgreementsfortheCC-9MW3AMM, 804 Orange Ave., Sanford, 'L You will need to print TWO copies and return BOTH to BSE for Lionel's signature (One Nvdl be scot back to you with original signatures for -Your records). a- Initial ALL pages of the boiler Plato agreement in the lower right hand corner. b. Fill out Page 11, including Contact Information (if not already completed by BSE) c. Sign Page 11, provid.e.2 witnesses and add your. Tax ID number d. Exhibits (Keep copies for your records and return only the ones indicated to BSE) A. Nothing to fill out, form for your future use (Return to BSE with initials) B. Sign and Date at bottom (Return to BSE with original signature) . C. initial each page (Return to. BSE with, original signature) D.. D. l and D.2 nothing to fill out,forms for your future use (Return to BSE with initials) F. Sign, Date, and have Notarized (Return to BSE with original signature) G. Nothing to fill out (Return to BSE with initials) H. Nothing to fill out (Return to BSE with initials) e. Return. TWO (2) S,IGNED copies of the Agreement and required exhibits to: Black Street Enterprises,LLC 13245 Daniels Landing Circle Winter Garden. FL 34787 Attn: KEITH OWENS ALONG WITH: i- V21id're6iotration for Sominolc.County ii. Certificate of Insurance naming Black Street Enterprises, LLC as additional insured Fax ( 866) 674-1239), in compliance with 1. General Liability coverage 2. Workanan's Compensation coverage 3. Automobile coverage iii. W-9 form, completed in full iv. Copy of your Florida certified license, if applicable f. Upon our receipt, we will review and send you back a copy executed by Black Street g: Call Keith Owens (407) 388-5820 with any questions Trade: HVAC Subcontractor. A13Co01 Heating S Air SUBCONTRACT AGREEMENT Agreement) is executed this 1 day of April . 2014, by and between Black This Subcontract Agreement (Ag Referred to as Subcontractor). Street Enterprises, iLC (referred to as BSE) and ABCooI Heating &Air: a ed Subcontractor to perform the Work at the Property, for the Trade listed above, andBSEhasengg described in Exhibit ,V and any attached proposal. atthe prices and upon the terms and conditions The Subcontractor desires toperform the Work at the Property, of their ll agree as follows: Agreement. BSE and Subcontractor, in considederation, mutually mutual Covenants andration as expressed in thisgagreementsinthisAgreement and for other good and valuable cons) 1 n the Agreement DEFINITIONS — Unless defined elsewhere in the Agreement, the capitalized terms i have the following meaning: attachments, and a -Agreement" means this Subcontract Agreement and all schedules, exhibits, includes the Construction Documents. statin their b) "Change Order" means a written instrument signed by BSE and Subcontractor, g agreement to adjust the Work and Price in the Agreement. (See Exhibit "A" ). c) "commencement Date" means the date that the Work begins. d) "Construction Documents" consists of all of the design documents prepared for the Owner by hisdesignprofessionals, including architectural, structural, mechanical, electrical, plumbing, andlandscapeplans, as well as and the Scopes of Work Specifications prepared for the Subcontractor See Exhibit "C"). The Construction Documents, if any, are incorporated as part of the Agreement. See Exhibit "E"). e) "Effective bate" means the date this Agreement is executed by the Parties. f) "Indemnmed pal -lies- means all partiea indomnified by Subcontractor in Paragraph 7.d. including butnotlimitedtotheOwner, BSE, their officers, affiliates, independent contractor associates, and employees. g) "Job" shall mean all of the Work to be performed at the-Property,.that BSE has been engaged to perform by the Owner. h) "Owner" means the party that has engaged BSE to complete the Job at the Property. i) "Parties" means BSE and the Subcontractor. j) "Price: means the total amount payable by BSE to the Subcontractor for the Work, in stages, if any, including any adjustments made by Change Orders. (See Exhibit "B") k) "Property" means the real property described by the address 804 Orange Ave..Sanford. FL32771, that is owned by Owner Dinah Wright 1) "Term" means the period between the Effective Date and the end of the Subcontractor's Work and warranty period. m) "Work" means the construction and services required by the Agreement and the Construction Documents, and include all labor, materials, equipment, and services to be provided by the Subcontractor. 2 80.9 Orange Ave. HVAC. ART - BOILER AGREEMENT.BSE.docx INITIAL pane 1 of 11 n) "Exhibits" to this Agreement are as follows: i) Exhibit A — Sample Change Order ii) Exhibit B — Price and Time Schedule id from the iii Exhibit.0 — Subcontractor Scope of Work. If and overn any conflict. Subcontractor is attached, then the Exhibit C Scope of Work shall prevailg iv) Exhibit.D.1' and D.2 —par , tial and Final Release of Lien Forms v) Exhibit E — List of the Construction Documents vi) Exhibit F — Affidavit of independent Contractor Status vii) Exhibit G — Davis Bacon Act Wage Determination viii) Exhibit.H -Section 3 information 2) Complete Agreement; Merger Clause shalt be deemed to bind the Parties. All prior negotiations andThisAgreementcontainstheentireagreementbetweentheParties. No other agreements, representations, warranties or other matters, oral or written, representations are merged into this Agreement. 3) Payment. a) Subcontractor shall not,perform any work unless so requested by BSir. b) Payments, subject to additions and dtheductionsbyChange xed order., price, l be made in completion ofrthe Wodance rk. the Price Schedule (see Exhibit B1. The Pnce is roved and c) No extras; additional labor .or materials or changes will be paid if not previously app issued on a Change Order; d) Subcontractor shall furnish BSE with partial or final affidavit and release forms from Subcontractor asapplicableaswellasfromanylowertiersubcontractorsorsuppliers. ny e) Payment to Subcontractor will not constituterelieve Subcontractor Off any of is obl gat o sork, or waiver of a SSE will not be under this Agreement and dots of BSE es not retie of the following conditions exist (iyobligatedtomakeanypaymenttoSubcontractorifany (••) Subcontractor has failed to perform any of its obligations or is in default under the Agreementses in u Subcontractor has failed to furnish BSE with invoices, signed receipts, vouchers and lien releas or waivers; (iii) Any part of a payment requested is for Woto any rk that is defective, or not performed of accordance with the Agreement.; (iv) Subcontractor has.failed to make payment promptly its subcontractors, suppliers oremployees; (v) BSE' reasonably determines that the amounts; then remainingunpaidtoSubcontractorwillnotbesufficienttocompletetheWorkandcorrectdeficiencies in the Work; (vi) Subcontractor has failed to procure, maintain or pay for required insurance as described in herein or NO SSE has received payment from SSE's.`ciient or customer f) BSE has the right, whenever it deems advisable, to make payments by joint checki To any lower tier subcontractors or suppliers that Subcontractor has failed to pay. g) Final payment.. subject to withholdings permitted hereunder, shall be made after Subcontractor's work has been fully completed and approved by BSE'in writing; and satisfactory proof of payment of all amounts owed by Subcontractor in connection with the Agreement has been provided. h)' The Retention amount, if any, as described in the Price Schedule (see Exhibit "B"), shall be paid to Subcontractor upon the later of (1) .after all Subcontractor obligations have been fulfilled to the reasonable satisfaction of BSI=, or (2) sixty (60) days after the Subcontractor has. completed the Work i) Payment is to be made, subject to the condition precedent stated below, in current funds at such time as the contractor receives them from the owner. It shall be a condition precedentto any liability of the contractor to the subcontractor for any payment .to the subcontractor that. the contractor be in receipt of payment from the owner for the subcontractor's work. If the owner, has not paid the contractor for any reason whatsoever, including the owner's inancial.inability'to py or other reason not related to this subcontractor, the subcontractor agrees that the contractor shall notbe liable for 2 PO4 oranae Ave. HVAC. P.RI EOILER AGREEMENT.HSE_dcch Page 2 of 11 nvrriat. The subcontractor assurnes the creditsubcontractor. nor be indebted to the aowner's credit and not of the contractor. risk of the owner and agrees that he has relief on th 4) prosecution of the Work, n written notification to do so from BSE and willillstarttheWorkimmediatyupodillent a) Subcontractor wan proceed with the Work during normal business hours until and agreed time sched e, ( See workmanlike manner, in strict accordance with 'the A9 em Exhibit "Cl, and in such time so as not to delay the other trades. four (24 hours written notice, Subcontractor is unable or b) if in BSE's sole opinion and after twenty- )with the Agreement, which results in unwilling to commence and efadeshen SSE may, at accordance optionafter an additional forty-eight (40) delays of the Work or rovide through whatever means BSE determines is houropportunityforSubcontractor` to cure, p portion of the Work. reasonable, any such'work and deducc'the h pwith Subcontractor for allue to o rany p oti Further, BSE may at its sole option terminate its vela Pand take possession, for the purpose of and will have the right to enter upon the Property finish the completing the Work, of Subcontractor's materials, tools r contractors, aand Subcontractor rwill not be entitled he Work, eitherwithitsownemployeesorotherbyBSEincompleting. receive further payments under the Agreement. If the expenses S bcontractincurredwill pay the difference to Work exceed any unpaid balance due to Subcontractor, BSE"together with, 1) interest at the rate of one and -half percent default (t 5%) and ii) any and all other damages incurred by BSE as the result of Subc5) Time ofperformancea) Subcontractor will proceed with the Work in a prompt and diligent manner, in accordance with BSE's schedule asreasonablyamendedfromtimetotime.. TIME IS OF THE ESSENCE. b)" If requested by BSE; Subcontractorshail submit a detailed schetdhUlae fll orperformance, utorementsftheoofthe in:a form acceptable to BSE, which schedule shall comply Agreement_ BSEmay, in its sole discretion, direct Subcontractor to make reasonable modifications and revisions in the schedule at no extra.cost. c) Subcontractor will coordinate its work with the work of BSE's other subcontractors so no.delays or interference willoccurinthecompletionofanypartoftheJob. 6) subcontractor' s Investigations and Representations a) Subcontractor represents that if is fully qualified, can perform the Work with the highest quality standards, andhastheexperienceandcapacitytoperformtheWork, and Subcontractor has, with a view towardeliminatingambiguitiesorextrawork, investigated (i) the required Work, (ii) the conditions involved inperformingtheWork, and (iii) the obligations of this Agreement: and (b) verified all information.furnishedbyBSEorotherssatisfyingitselfastothecorrectnessandaccuracyofthatinformation. b) Subcontractor is responsible for inspecting the Property, and commencement of the Work is an acknowledgment thatthe.Property is safe :and ready for the Work to commence and proceed in a good and workmanlike manner and compliance with all applicablelaws, codes and regulations bearing on the Work. Subcontractor further representsthat it is fully familiar with the requirements of any governmental authority having jurisdiction over the Work and' is prepared to and will comply With all such requirements without additional compensation. c) Subcontractor understands and agrees that BSE is not responsible for providing any on -site utilities. Subcontractor shall be responsible for providing, at no additional cost, all utilities necessary to perform the Work,. including but not limited to water and %electricity. d)` The Subcontractrs suppliers, agents or employees shall not take photographs of the work on site, or publish or display advertising matter of any description, without first obtaining the written consent of BSE. e) Subcontractor shall schedule all inspections; required by all governmental agencies having jurisdiction so as not to interfere With the progress of the Work to be performed by Subcontractor and other subcontractors. Subcontractor shall promptly replace or correct any Work or materials, which 2 804 Orange Ave. HVAC. ARI - 'BOILER RGREEMIENT.BSE.docx INITIALitit Page 3 of 11 Orl to the requirement of Subcontractor or any inspection shall reject as failinet to 48 (hours after written notice to correct Agreement. If Subcontractor does not so within forty- 9 { ) tor shall be liable deduct. the same, SSE shall have the right to do so and S k o°materials, then BSE at its option, may of. u it is not expedient to correct or replace rejected Work payments due, onto become due to $ en the fair vactO lue of therinsucharerejectedWorkanmountas, in d materials and the value will represent (i) the difference betweenAgreement, or (ii) the'cost of correction; whichever.is higher. thereof if the Work complied with the 7) subcontractor's l.iabirdy a) Subcontractor shall comply with Section 3 of the Housing and Urban Development Actgenerated by U.S.C. 1701 u) (Section 3) to ensure that employment and other economic opp certain 1701 financial assistance shall, to the greatest extent feasible, be directed to low AndAsvery art of low income persons, particularly those who are recipientsbleforcompfancre 'witmenth assistance pplicable housing requirement,- as this project, subcontractor will be responsibledefinedinPart135ofSection3regulations (See Exhibit H). b) Subcontractor shall provide and pay for all tabor; materials, equipment, tools, construction equipment and machinery, water, heat, utilities, ntransportationaSubcontractor assumes the responsibi ty and liability foerfacilitiesandservicesnecessaryrall proper execution and completion of lies, and materialsuntil final acceptance of the WorkWork,, supervision, labor, equipment, tools, sul p from Willful mi conduct or by BSE. In the event of any loss, damage or destructiono subcontractors Subcontractor shall be negligence of the Subcontractor or its agents, employ a or destruction.. liable. therefore, and shall repair, rebuild and make good to SSE said loss, damag. c) suppliersSubcontractorshallbeliabletoBSEforalol failureets perfordrrtas a shall nclude the failuURofrreofitssuppe to perform<this Agreement Subcontrashal include, and/or subcontractors of any tier to perform. Subcontractor's IE s inCre'ased c sts of performancce, to (1) damages and other delay costs recoverable by BSE; Q) such as extended overhead and :increased/added performance costs resulting from Subcontractoreworkcosts; (4) liability to third parties; (5) excesscauseddelaysorimproperWork; (3) warranty and r. costs-, and (6) attorneys fees and related costs. d) In the event that Subcontractor or its subcontractors utilize any machinery, equipment, tools, scaffolding,.hoists, lifts or similar items belonging. to or under the control of.BSE, Subcoe onelrin wshall be liable to BSE for any loss or damage (including property. damage, economic loss, p injury and/or death) which may result from such: use, except where such loss or damage shall be due solelytothegrossnegligenceofBSE's employees operating equipment owned or leased by, BSE. e) Subcontractor shall. indemnify, defend, and hold harmless the Indemnified Parties, including theOwner, BSE, their officers, affiliates, independent. contract associates; and employees from liabilities; damages, losses and costs; including but not limited to reasonable.attorney'.s fees to the extentcaused byfifenegligence, recklessness, or intentional wrongful misconduct of the Subcontractor and/or all personsemployedorutilizedbytheSubcontractorintheperformanceoftheAgreement. SubcontractorshaltassumeonbehalfofOwnerand/or BSE and all Indemnified Parties;and conduct with due diligence and in good faith the defense thereof with counsel satisfactory'to BSE; provided, that the Indemnified Parties shall have the right to be represented by counsel of its own selection; and provided further, that if the defendants in any such action include Subcontractor. and any or all of the Indemnified Parties, then the Indemnified Parties shall have reasonably concluded _that there.may be legal defenses available to it which are different from or additional to; or inconsistent with, those available to Subcontractor, Construction Manager and/or Owner shall have the rightto have and select. separate counsel to participate in the defense of such action on either one or both's behalf at Contractor' s expense. In the event of failure, by Contractor to fully perform in accordance with this subsection, the Indemnified Parties, at its option and without relieving Subcontractor of its obligations hereunder, mayso perform. In that event all costs and expenses so incurred by the Indemnified.Parties from the date any such expense was,paid by it or them until reimbursed bySubcontractor, shall also bear interest at the highest rate allowable by law. 8) Protection of Worts 2 804 Orange Ave. RVAC. ARI - BOILER AGREENENT.BSE.docx Sage 4 of 11. c) At BSE's sole discretion, BSE may withhold from any payments due Subcontractor, reasonable amounts to secure Subcontractor's performance of its warranty obligations hereunder and offset against such amounts any warranty costs. 14) Liens a) In the event that liens are filed by anyone working under Subcontractor, Subcontractor agrees to have the same released,. discharged, or transferred to bond or cash deposit pursuant to Florida Statute 713.24 within five (5) days of written notice from BSE. In the event such lien is not.timely released,. discharged, or transferred the Subcontractor may be terminated or BSE may bond the lien. and back charge all costs, at BSE's option. b) Prior to final payment Subcontractor shall provide BSE a release of all liens and claims, and releases or waivers of all liens and claims of all persons furnishing labor.and/or materials through Subcontractor, and a final Subcontractor's affidavit truthfully reflecting no unpaid lienors under Subcontractor (See Exhibit "D.2"). c) As a condition precedent to entitlement to any subsequent payment, Subcontractor shall famish uncondfional releases of lien with respect to all prior payments, as part of each request for partial payment other than the initial request (See Exhibit"DA). d) BSE may issue joint checks to the. Subcontractor and any unpaid subcontractor, laborer, orsupplier. 15) Shop Drawings, Submittals, and Samples a) Subcontractor shad deliver to BSE 3 copies of shop drawings, cut sheets, samples and material lists required by. BSE, or the Construction Documents within sufficienttime so as not to delay performance of the Work and within sufficient time for BSE to submit the same to the design professional for review. Any deviation or change` from the Construction Documents must be clearly, identified on shop drawings and be accompanied by a letter describing such deviation or.change in detail along with the effect, if any; on the Subcontractor's Work and time of performance. b) BSE's review of shop drawings, cut sheets, samples and material lists is :only for the convenience of the BSE in following. the Work and: shall not relieve the Subcontractor from responsibility for any deviations from the requirements of the Construction Documents. 16) Clean Up Subcontractor shall daily, and upon completion of the Work, clean the site to BSE's satisfaction, including removal of all debris and other materials left.by Subcontractor, to a place designated by BSE for such: purpose. If Subcontractor fails to do so, Construction BSE may impose a cleanup back .charge for each day the Subcontractor fails to do so. 17) Subcontractor's Representatives An authorized, competent representative of Subcontractor fluent in English shall be on site at the Project site during all working hours. This representative must be able to read and understand all Hazardous Material literature relevant to the Work. This representative shall be authorized to make binding decisions on behalf of Subcontractor. Subcontractor shall provide BSE with. the proper names, phone numbers, mobile phone numbers and:e-mail addresses of its key field and home office personnel. 18) Back Charges Subcontractor shall resolve all back charges received from BSE within thirty (36) days after receipt of a back charge, and if the.same are not resol.ved within;said thirty (30) days, Subcontractor shall be deemed to have waived any assertions relating to the back charges. 19) Assignment and Subcontracting Subcontractor shall not assign or transfer Agreement or funds due hereunder, withoutthe prior written consent of BSE. All subcontracts and change orders awarded by Subcontractor are intended to be for the benefit of the BSE. All subcontracts of lower tier subcontractors shall be assignable by each such subcontractor to BSE upon the default termination of the Subcontractor.. 2 804 Orange Ave. HVAO. ARI - BOILER AGREDENT_ESE_dcex M111AL V Page e cf 11 nd agents thereof l comply a) Subcontractor and all employees, issued pursuant to the occupational asafety and Health Act Of 1970,. with the: applicable requirements be as amended and all other applicable health and safety laws and a gtsulof commission orotmissomission by liable to SSE for all loss, cost and expense attributable to anyactsission y Subcontractor, its employees and its subcontractors resuitin from failure to comply including, but not.limited to, any fines, penalties or corrective measures. b) Subcontractor at all times will furnish to its lower v olatiobcontractors and n of ppl cabe t wl by. any party, oyees a safe place will employment. If Subcontractor observes any immediately report such violation to SSE in writing. c) Subcontractor shall be subject up to $150.00 fine pefederal;safetycst ton and loclal requirements l maintain a itten safety program that complies with OSHA and all applicable d) Subcontractor will immediately notify SSE in writing in the event of an OSHA inspmeetictithe. Subcontractor shall maintain at thesite al Safety ata Shets Standard ND 313 for each(matuerial it brings onto requirements of 29 GFR 1910.1200(g) and Federal the Site. e) Subcontractor should maintain documentation training, weekly safety meetings, and additional site specific" programs not covered herein. f) It is each Subcontractor's responsibility to provide the following: i) Safety training for their own employees. ii) Maintain its own safety records. including OSHA iii) Provide all Personal Protection Equipment (PPE) for their employees, approved hard hats at all times iv) Provide respiratory equipment, if applicable, to their employees. v) Provide SSE a) a list of all hazardous substances that the subcontractor will use on the project, and b) a copy of the MSDSs for each of those hazardous substances. 9) Hurricane readiness, including but not limited to strapping.roof tiles, and securing the project site, shall be undertaken by Subcontractorinaccordancewithallapplicablecodes, laws and regulations at no: additional expense to BSE. 11) Changes a) BSE may, at any time, without notice, make changes in the Work. Any Change Order shall be in writing. Subcontractor shall performtheworkinaccordancewiththeChangeOrder- b), Subcontractor shall submit any claims for adjustment in the price or time of performance to BSE within seven (7) days ofthereceiptofthe.Change Orderi and before beginning any changed or extra work. BSE shall review theSubcontractor's requestand shall notify Subcontractor if such request has been accepted or rejected. Iftherequestisrejected, SSE shall discuss with Subcontractor the reasons for the denial of thepriceadjustment. If the parties are unable to agree on a price adjustment, both patties shall have the righttoterminatethisAgreement: Failure to timely give written notice.of sucha claim(s) shall be a waiver of any claimfor extra cost or extra time. c) Subcontractor shall, within seven (7) days of any request from HSE. Submit a reasonable price quotation for proposed changes. 12) Termination of Agreement a) 2 809 Orange Ave. HVAC. ART - BOILER AGRELNENT.BSE.docx Page 6 of 1. 1 BSE may terminate all or part of Subcontractor's right to perform the Work under this Agreement or any Change Order upon forty-eight (48) hours written notice to Subcontractor. upon receipt of such notice, unless directedotherwise, Subcontractor will immediately discontinue prosecution of the Work and the placing of orders for materials, equipment, machinery and supplies in connection therewith and will, if requested, make every reasonable effort to procure cancellation of all existing orders for contracts upon terms satisfactory to BSE. Then, unless otherwise directed by BSE, INITIAT Subcontractor will only do such work as may be necessary to preserve and protect that portion of the Work that has been incorporated into the Work and to protect materials, supplies and equipment at or about the site or in transit thereto. b) On the date set for the termination, the obligations of the parties to continue performance under this Agreement or Change Orders will cease. If, in the sole. opinion of BSE, the Subcontractor' shall at anytime (1) refuse or fail to provide sufficient and properly skilled workmen, or materials of the proper quality and sufficient quantity to maintain the progress of the work (2) fail in any respect to perform the Work according to the current schedule, (3) cause, by any actor omission, the stoppage or delay of or interference with the Work or the work of any other subcontractor, (4) fail to comply with any provision of this Agreement or the Construction Documents, (5) be adjudicated bankrupt; or make a general assignment for the benefit of its creditors, (6) have a receiver appointed, or (7) become insolvent or a debtor in reorganization proceedings, then, after serving three (3) days' written notice, unless the condition specified in such notice shall have been eliminated within such 'three (3) days, BSE; at its option (i) may take such steps as are necessaryto address the failure or condition, including but not limited to supplementation of the Subcontractor's workforce by other personnel supplied, in which case the Subcontractor shall be liable to BSE for the cost thereof, (ii) terminate the Agreement for default. In the event.of termination for default, BSE may, at its option, (a) enter upon the premises and take possession, for the purpose of completing the Work, of all materials, tools and appliances, supplies, and equipment of Subcontractor, (b) require Subcontractor to assign to BSE any or all of Subcontractor's subcontracts or purchase orders involving the Work, or (c) complete the Work by whatever method. BSE may deem reasonable. to case of termination for default;. Subcontractor or shall not be entitled to receive any further payment until the Work shall be fully completed and accepted by BSE. At such time, if the unpaid" balance of the price shall exceed the "expense incurred by BSE to complete; such excess shall be paid by BSE to Subcontractor. If such amount to complete and correct shall exceed such unpaid balance, then Subcontractor shall pay BSE the difference. Upon a default by Subcontractor, BSE may retain from any sum owed to Subcontractor all sums as may be owed from Subcontractor to BSE. BSE may retain a sufficient sum to protect, itself from any claim or demand asserted against it by a`third party as a result of work performed by Subcontractor hereunder until such claim or demand has been satisfied. c) Notwithstanding any other provision to the contrary, the termination of this Agreement or any Change Order will not prejudice any claim of either party arising prior to termination, or relieve either party from :any liability arising prior to termination, nor will it affect :Subcontractor's guarantee of the portion of the Work performedor relieve Subcontractor of its duty to correct any defective Work performed or to indemnify, defend and hold BSE harmless in those instances required by this Agreement.. d) BSE may terminate this agreement for convenience, without cause. In the event of a termination for convenience, the Subcontractor shall be paid the reasonable value of the work in place and any reasonable demobilization cost, but no lost profit on unperformed work. 13) Warranty a) The Subcontractor warrants to 13SE that materials and equipment fumished under the Agreement will be of specified quality and new unless otherwise required or permitted, that the Work will be free from defects, and that the Work will conform to the requirements of the Agreement. Work not conforming to these requirements including substitutions not previously approved and authorized before installation, may be considered defective. If required by BSE, the Subcontractor shall furnish satisfactory evidence as to the kind and quality of materials and equipment. The Warranty provided shall continue for a period of one (1) year next following the issuance of a Certificate of Occupancy for the building in which the work is done. b) Subcontractor shall remove and, repair or replace any defective workmanship, material, and/or equipment which defect occurs within one (1) years after acceptance of the work or within such longer period as may be provided in the Agreement at Subcontractor's expense and BSE's convenience. Subcontractor shall also pay all expenses incurred in removing, replacing or repairing any work that results from removing, replacing or repairing any part of its defective work: 2 804 Orange Ave. HVAC. ARI - BOILER AGREEMENT.BSE.docx Page 7 of 11. INITIAL a) Subcontractor will supervise, administer and protecttheWork against loss or damage from any causeandberesponsibleforallpartsoftheWork, temporary or permanent; finished or not, until inspected and accepted by BSE. Subcontractor will take reasonable precaution. n d maintain reasonable safeguards to protect against loss or damage to persons or property 9 to weather conditions including, but not limited to bracing and reinforcing where necessary. b) Subcontractor shall maintain the site in a neat and orderly condition consistent with reasonable conditionsassociatedwithaconstructionjob. This shall require removal of debris and garbage on a. daily basis. The site shall at all times be maintained consistent with local government requirements. All garbage and debris shall be stored in containers maintained at or adjacent to the site in approved locations 9) Prepara bon Immediately following execution and delivery of this Agreement; Subcontractor shall make appropriate preparationstoperform .the Work, including all of the following; which must be completed within 10 days followingfromEffectiveDate.or prior to the commencement of the Work, whichever is sooner: a) Insurance i) Subcontractor; at its cost, through the term of this Agreement; shah obtain and maintain in force andeffectthefollowinginsurance (with such insurance company rated no less than A- by AM BEST) with respect to.Subcontractoes operations under this Agreement: n) Worker's Compensation: Worker's compensation insurance covering all employees of Subcontractor in the amount of Subcontractor's full statutory liability. Exemptions are not permitted. iii) Employer's Liability: Employer's liability insurance with a.limitation of liability of at least $500,000 per accident or disease. iv) General Liability Insurance: Comprehensive General Liability Insurance with coverage limitations of not less than $1,000,000 combined single limit v) ' Contractual liability, completed operations; and environmental insurance. vi) Automobile Liability: Automobile liability insurance for personal injury or death with coverage limits of not less than $1,000,060 combined single limit. b) ' Subcontractor will `supply BSE with Certificate(s) of Insurance evidencing the required coverage at leastten (10) business days prior to Subcontractor's commencing the. Work. No certificate will be acceptableunlessitprovidesthatanychangeorterminationwithinthepolicyperiodswillllenotunder be effective unless and until BSE has received thirty(30) days prior written notice. Any. anyinsurancepolicyshallbepayablebySubcontractor. If Subcontractor's insurance coverage is not inforce; BSE may withholdpayment until the required insurance is obtained and evidence is submitted to BSE. c) If Subcontractor fails to obtain or maintain any required insurance, BSE shall have the option, but not the duty, to obtain or maintain such insurance for the account of Subcontractor, with all costs.incurred by BSE to be reimbursed by Subcontractor upon demand. d) All insurance must.name Owner, BSE and Subcontractor as co-insured, must be written by companies authorized todobusiness.in the State of Florida that are acceptable to BSE and must not contain any right of subrogation against Owner or BSE. e) Site Requirements Subcontractor shall. deliver to BSE a detailed written statement specifying the particulars, if any, in which the site is not in proper condition to receive the Work. Failure.to furnish such statement shall constitute an acceptance of the site, and act as a waiver of all claims by Subcontractor against BSE. f) Permits Subcontractor will obtain at itssole cost and expense all permits necessary for the Work. 10) Health and Safety 2 804 Orange Ave. HVAC. ARI - BOILER AGREEMENT.BSE.docx Page 5 Of 11 20) Taxes and permits Except as -otherwise provided by the Agreement, Subcontractor agrees to pay and hold the BSE and ,BSE harmless from the payment of all contributions, taxes, and/or premiums which may be payable bySubcontractorarisingoutoftheperformanceofthis .Agreement; as well as all sales, use, or other taxes of whatever nature levied or assessed arising out of this Agreement including any interest or penalties. Subcontractor waives any and all claims for additional compensation because of any increase in theaforementionedtaxesunlesspaymentforsaidincreaseisspecificallyprovidedforintheAgreement. Subcontractor shall obtain and pay for all permits, licenses, fees and certificates of inspection necessaryfor the prosecution and completion of.its work, and shall arrange for all necessary inspection and.approvals by public officials. 21) Laws, Regulations' and Ordinances a) Subcontractor agrees to be bound by, and, at its own cost, comply with all federal, state, and local laws, codes, ordinances and regulations applicable to this Agreement and the performance of the Work whether by reason of -general law or by reason of provisions in the Agreement. Subcontractor shall be duly licensed to operate under the law of the applicable jurisdictions. b) Subcontractor shall comply with Section 3 of the Housing and Urban Development Act of 1968.(12 U. S.C. 1701 u), (Section 3) to ensure that employment and other, economic opportunities generated by. certain HUD financial assistance shall, to the greatest"extent feasible, be directed to low and very low income persons, particularly those who are recipients of government assistance of housing. As part of this project, subcontractor will be responsible for compliance with all applicable requirements as defined in Parti35 of Section 3 regulations (See ExhibitH): 22} Severability and Waiver. A partial or complete invalidity of any one or more provisions of this Agreement shall not affect the validity of the remainder of the, contract. Any such invalid clause shall be considered severable. 23). Jurisdiction; Service Of Process This Agreement contains the entire Agreement between the Parties hereto and. shalll-supersede all other agreements,. either oral or written, between the Parties. This Agreement cannot be modified or amended without the express written consent of the Parties. This Agreement shall be construed in accordance with thelawsoftheStateofFlorida. In.the event of litigation between Parties, the venue will be the courts of the State of Florida, St, Lucie County and the Parties will accept service of process of such `courts. 24) Dispute Resolution Subcontractor and BSE;;hereby knowingly, voluntarily and intentionally waive the right to atrial by jury for any litigation arising rout, of under, or in connection with this Agreement; In connection with any such litigation, the prevailing partyshallbeentitledtorecoveritsreasonableattomey's fees and costs, incurred at both trial. and appellate levels. Such fees are limited to 50 000.. These provisions are material inducements.for the parties to enterintothisAgreement. Venue for any such litigation shall be in a court of competent, jurisdiction in St., Lucie County, Florida. 26) Independent Contractor. Per Exhibit " FA, Subcontractor is an independent contractor with respect to the Work, and neither Subcontractor nor anyone employed by Subcontractor will be deemed for any purpose to be the :agent,. employees, servant or representative of BSE in the performance of the Work. 26) Moisture Intrusion Prevention and Mold Action Plan b) Any moldy, wet, or damaged materials will be segregated and retumed by Subcontractor to.his suppliers, and is not to be used. c) Any water on the surfaces of building.construction materials and packages should be wiped dry before:storing to avoid adding moisture to storage areas. d) Subcontractor must follow manufacturer's direction for .material storage. These instructions must. be followedforwood; wood products, insulation materials, drywall, carpet, fabric, and paper products. 2 804. Orange Ave. HVP.C. ART - BOILER ",bRCEMENT:BSE.'docx INIITAI J Page 9 Of 11 e) Subcontractor to provide immediate notification to BSE of any and all moisture intrusion, includingbutnotlimitedtopipeleaks, condensation, flooding, window leaks, roof leaks, door threshold leaks or sliding glass door leaks. f) Subcontractor shall visually inspect building materials delivered to the site prior to storage to ensure building materials were delivered in original, factory sealed, .unopened packages containers orbundles. Wet or moldy packages must be rejected and returned or segregated from clean materials for. resolution. g) Segregate those packages with mold and/or water damage to eliminate spread of mold to clean materials in the storage area. Do not use drywall which has been exposed.to the elements. h) All piping (mechanical, electrical, plumbing, and fire sprinkler) risers should extend above slabs aminimumof4" and be caulked or foamed to prevent moisture intrusion through slabs. 27) Subcontractor's Commitment. to Customer Service The Subcontractor agrees to provide excellent Customer Service and follow the Customer Service Policy fisted below: b) Be on time for appointments and call BSE if more than 15 minutes late. c) Will not criticize the work of other subcontractors in front. d) Will not argue with or disrespect Owner, Owner's representatives or BSE. e) No smoking in any structure or building on the Property at any time or at any stage. f) No eating in the house at any time or at any stage. g) No tools or materials on countertops or other finished surfaces, regardless of protection. h) No shoes worn inside the Job after flooring installed. i) Close all windows and doors at the conclusion of a workday, or Subcontractor may be responsible for water damage. j) All service personnel to be dressed and groomed neatly when with Owners. k) Ask BSE to sign the service ticket when the work has been completed. Return these to BSE, within10daysofissue, or BSE will not know that the work has been completed. SSE, reserves the righttowithholdanymoniesdueSubcontractorifserviceworkisnotcompletedonatimelybasis. , 2 804 Orange Ave. HV'AC. ARI - BOILER AGREEMENT.BSE.dccx Page 10 of 11 INI C receiptrequested,addressed 28) Notices giveshall required to be be given by Certified Mail, return w: n heCein Ail notices q or Parties. as stated in below: tothepersonsS'ernine"Je.County 13 C C As to the 'Owner - 1101 E 1at Stre et Sanford, Florida 32771 As to Contractor. Black Street pnterpBSess LLC 536 t4W Mercantile uce, #107 PPort St. Lucie; FL 34986 As to the ABCo6l Heating & Air Sub - contractor: 32 S Hudson Street Orlando, Florida 32836 29) Subcontractor Contact Information Contact Berson M2nnie Wooten Mailing Address 32 S Hudson Street, Orlando, Florid 3283 Office Phone Number 407) 297-0550 Cell Phone NUMDer Fax Number Email Address Emergency Service Contac Emergency Service Phone Failure to respond immedir I Manure Wooten rsonnber ( 407) 297-0550 Shall resultin a back charge emergency acfion UNDER NO CIRCUMSTANCES SHALL EITHER PARTY BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL, OR PUNITIVE DAMAGES, INCLUDING, BUT NOT LIMITED TO LOST PROFITS. THIS WAIVER OFDAMAGESSHALLAPPLY. REGARDLES OF WHETHER ANY PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH CLAIMS. IN WITNESS WHEREOF, the parties, by their duly authorized representatives, have agreed to the terms and conditions of this Agreement. WITNESSES: SUBCONTRACTOR: ABCooI Heatina & A' Signature: YU (' Title:`' J TAX I.D. NO. 0147 7 --77 7 Subcontractor' s License No. BLACK STREET ENTERPRISES, LLC: By: Title: 2 904 Grange Ave. HVAC, ARI - BOILER AGREEMENT.BSE.docx NITTAL Page 1_1 of 11 esignStar Load Calculation Results are intended for use with Rheem heating and cooling systems Street Address 804 Orange Ave . Sanford. FL 32771 Latitude, Longitude 29.1462°„ 81. 05340 House Square Footage: 1503 sq. ft. Dame: Phone: Email: ro SH R 75 Number of residents 2 Ceiling height g Mall U-value ( R-value 0.09 1 11 Floor U-value ; R-value 0.2 1 5 Ceiling U-value j R-value 0.053 j 19 Window U-value 0,5 Window SHGF 0.85 Moisture grains 58 Duct I oss % 10 Duct gain % 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 Summer ventilation 0 GraphAED UU 10000 - aa J 5000 0 8am gam 10am 11am 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm Hourly Loads — Average System equipment selection will be made using the following derived values. Glass (E) 109 sq. ft. Glass (S) 15 sq. ft. Glass (N) 15 sq. ft. Glass (W) 76 sq, ft. Summer Outdoor 90OF Summer Wet Bulb 770F Summer Indoor 750F Summer Design Grains 50% Winter Outdoor 370F Winter Indoor 70OF Sensible Cooling 23,985 Btuh Latent Cool i ng 5,422 Btuh Required Cooling Airflow 1,090 CFM Sensible Heating 24,224 Btuh Required Heating Airflow 315 CFM All calculations are based upon approved hvac industry standards and procedures, and comply with all local, state and federal code requirements. All computed results are Estimates. Product provided by Energy Design Systems and Idea Tree Ceiling Windows Infiltration 2629 10.9 3548 14.6 6089 25.1 System Efficiency Loss 2202 9.1 Total: 24224 Heating Loads 24,224 BTUlhr Floor Infiltration System Efficiency Loss Ceiling i Wall Windows I . ..... ...................... .. - ...... ........ .... . ..... Windows 11897 40.5 Seri-;ible Infiltration 2076 7.1 1-.1 . ... ....... Latent Infiltration 4962 16.9 System Efficiency 2371 8.1 Internal 2400 8.2 S rl it le People Load 460 119 Latent People Load 460 1.6 Toi-5:11. 29406 Sensible load 23985 Latent load 5422 SHR 0.82 Capacity at.75 SHR 2.66 Tons Windows Cool i ng Loads 29,406 BTU/hr Sensible People Load Latent People Load Wall Sensible Infiltration System Efficiency Internal qqmmmmw Ceiling Latent Infiltration i Side C 10 g 11 Bd Rm 5121, TR 3d Rm E TR 10I6 loxs '-707Rm86d 6 GONDENS6! Side 8 13 NOTE: 8040rangeAve. 3v71 Parcel ID 25-19-30-SAG-100E-0030 I 5 4 10x6 0 4 a sic% 0 10I8 loxs IM 2 3 Liv Rm i F- 1 i I. a doA TR:- TRANSFER REGISTERS IN EACH BEDROOM AHU:- 2.5 TONS AIR HANDLER IN CLOSET WITH 5KW HEAT CONDENSER:- 2.5 TON HEAT PUMP 15 SEER CONDENSER 18X24 FILTER BACK RETURN GRILL UNDER PLATFORM