Loading...
HomeMy WebLinkAbout3962 Saltmarsh Lp- 18-1135 - NEW SFHCOUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT BER: BUILDDINNG APPLICATIONI#000118-10000108 BUILDING PERMIT NUMBER: 18-10000108 1 x/,, ,cC c DATE: February 06, 2018 VI v'+' a`.1 UNIT ADDRESS: SALTMARSH LOOP 3962 17-20-31-502-0000-0430 TRAFFIC ZONE:022 JURISDICTION: TT" SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: Park Square Enterprises LLC ADDRESS: 5200 Vineland Road, Suite 200 ORLANDO FL 32811 LAND USE: Wyndham Preserve TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 3962 SALTMARSH LOOP/ WYNDHAM PRESERVE LOT 43 SFR DETACHED FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUE TYPE DIST SCHED RATE UNITS TYPE ROADS-ARTERIALS CO -WIDE ORD Single Family Housing 705.00 1.000 dwl unit 705.00 ROADS -COLLECTORS N/A Single Family Housing .00 1.000 dwl unit 00 FIRE RE / 00 LIBRARY CO -WIDE ORD Single Family Housingg 54.00 SCHQOLS 1.000 dwl unit 54.00 CO WIDE ORD Family Housiing 5,000.00 1.000 dwl unit 5,000.00PARIngle 00 LAW ENFORCE N/A DRAINAGE N/A 00 AMOUNT DUE 5,759.00 PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE OrSEMINOLECOUNTYROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQQUEST WITHIN 45 CALENDAR DAYS OF THE DATE ABOVE BUT NO LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE BUSINESS OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT ISSUED WITHIN 60 CALENDAR DAYS FROM THE DATE ABOVE of Sanford " ' 77 ", h CITY OF SANFORD MAR - BUILDING & FIRE PREVENTION t 6 2018 . PERMIT APPLICATION 3 r , mendDevelop nt application No: Zz Documented Construction Value: $ S19k,5W*V8 28(c,gZ5.00 Job Address: 3962 Saltmarsh Loop, Sanford (Wyndham Preserve lot 26) Historic District: Yes No Parcel ID: 17-20-31-502-0000-0430 Residential ® Commercial Type of Work: New X Addition Alteration Repair Demo Change of Use Move Description of Work: Construction of new single family residence Plan Review Contact Person: Michelle Parkison Phone:407-529-3135 Fax: Name Title: Permitting Manager Email: mparkisonng,,parksguarehomes.com Property Owner Information Phone: Street: Resident of property? : City, State Zip: No Contractor Information Name Park Square Homes/ Vishaal Gupta Phone: 407-529-3000 Street: 5200 Vineland Rd Suite 200 City, State Zip: Orlando, FL 32811 Fax: 407-529-3001 State License No.: CRC1330351 Arch. / MJS Home Designs Architect/Engineer Information Name: Eng. / Don Bolden Eng. Phone: Arch./ 250 N. Wymore Rd. Suite B Winter Park FL 32789 Street: Eng./ PO Box 530783. Debary FL 32753 Fax: _ City, St, Zip: Bonding Company: Address: E-mail: Arch. 407-629-6711 Eng. 386-668-7606 Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed withh the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 3 Permit Application 3 ozS 1) NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that ] will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ]CC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 4L*11 3- / • /8 Signature of Owner/Agent Date Vishaal Gupta Print Owner/Agent's N e 3• I. 18 tgn lure Notary -State o Florida Date 16 w;; ;' ••. MICHELLE PARKISON 4• Notary Public — State of Florida s Commission # GG 157861 My Comm. Expires Nov 5, 2021 nded lh National Notary Assn. Owner/Ag or Produced 1D Type of 1D 46-- 3• • /8 Signature of Contractor/Agent Date Vishaal Gupta Print Contractor/A s Name 8 q •., MICHELLE PARKISON at'. . e• Notary Public - State of Florida Commission # GG 157861 My Comm Expires Nov 5, 2021 Bonded Ihro* National Notary Assn. Contractor/ gen is ersonal y Known to Me or Produced ID Type of lD BELOW IS FOR OFFICE USE ONLY Permits Required: Building [sc]' Electrical a Mechanical [R' Plumbing[3 Gas Roof Construction Type: Occupancy Use: {Z7-1 Flood Zone: )(-SEE A-t ChGllttlV Total Sq Ft of Bldg: Min. Occupancy Load: 1 # of Stories: 2- New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes[] No g # of Heads APPROVALS: ZONING: al Ilia COMMENTS: Plumbing - # of Fixtures 7,0 Fire Alarm Permit: Yes No UTILITIES: /, / --4 WASTEWATER: ENGINEERING: WQ, 3 -l°I-1i3 FIRE: Ok to construct single family home with setbacks and impervious area shown on plan. 3'7.9 74 M p. Ale Sor ren+ri- A, CTg- BUILDING: SF A/ l Q l8 Revised: June 30, 2015 Permit Application 1ii ii IIIiI 011111111111i GRANT MALOYr CLERK ONNT BY9126 RSEMTOETCOUtOMY PTROLLER Fs 11 CLERK'S ;67" 7 (iFss) RECORDED , ig/o% 2l 14912: 1919. 0 RECORDING FEES 81i1.0o b I'PI RECORDED BY tsmith THIS INSTRUMENT PREPARED BY: Name: Tania Pickering Address: 5200 Vineland Road Suite 200 Orlando, Florida 32811 NOTICE OF COMMENCEMENT Permit Number: 18- 1135 Parcel ID Number: 17-20-31-502-0000-0430 The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information Is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) Lot 43 Wyndham Preserve Plat Book 81 / Pages 93-102 3962 Saltmarsh Loop, Sanford FL 32773 2. GENERAL DESCRIPTION OF IMPROVEMENT: Construction of a new single family residence 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: Park Square Enterprises LLC 5200 Vineland Rd Suite 200 Orlando FL 32811 Interest in property: Fee Simple Fee Simple Title Holder (if other than owner listed above) Name: Address: 4. CONTRACTOR: Name: Park Square Homes Phone Number. 407-529-3000 Address: 5200 Vineland Road Suite 200 Orlando, Florida 32811 5. SURETY (if applicable, a copy of the payment bond is attached): Name. N/A Address: N/A Amount of Bond: N/A 6. LENDER: Name: Fifth Third Bank Phone Number. Address: 5050 Kingsley Dr. MD: 1 MOCU Cincinnati, OH 45227 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)( a)7., Florida Statutes. Name: Phone Number. Address- S In addition, Owner designates of to receive a copy of the Uenors Notice as provided in Section 713.13(1 xb), Florida Statutes. Phone number. 8. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Vishaal Gupta, Executive Vice President SI of s or Lessee's (Pdni Name and Provide Signatorys TidalOmce) Wa+orized a % PaMernAanayer) State of _'PtaricLa County of Q j3U0Q _ The foregoing Instrument was acknowledged before me this day of .1 . V 2 L It byl-s tao'A l',p , Who is personally known to m9V OR Name or person nultinghuterrient who has produced Identification 0 type of Identification produced: TeNe M. Pidcerbtp NOTARY PUBLIC STATE OF FLORIDA Caron* 00002,898 E*m 81i1/ 2020 CER10E0 C09y GRANT MAIOy CLERK OF THECIRCUITCOURTMv% CotJIPTROIIER OR10A DEPUn CLERK Date REQUIRED INSPECTION SEQUENCE PARK SQUARE HOMES SFR-DETACHED Permit # BUILDING PERMIT Min Max Inspection Description 10 Form board / Foundation Survey 10 Slab / Mono Slab Pre our 20 Lintel / Tie Beam / Fill / Down Cell 30 Sheathing — Walls 30 Sheathing — Roof 40 Roof Dry In 50 Frame 60 Insulation Rough In 70 Drywall / Sheetrock 40 70 Lath Inspection 50 1000 Final Roof 50 1000 Final Stucco / Siding 80 1000 Insulation Final 1000 Final Single Family Residence Addrecc• E- EGTRICA L,•'PERIVIIT' Min Max Inspection Description 10 Underground Electric 10 Footer / Slab Steel Bond 20 30 emporary Underground Power TUG 30 Electric Rough 1000 Electric Final Max Inspection Descriptionr20Min10PlumbingUnderground Plumbing Tubset 10 1000 Plumbing Sewer 1000 Plumbing Final MEC_ ANIC AI:PERIVIIT• ,.',.: _-'=._...; -. ", ;=;i; Min Max Inspection Description 10 Mechanical Rough 1000 Mechanical Final REVISED: June 2014 MAR - i ?1018(- CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: l0—/z- __' Documented Construction Value: S 150,537.00 Job Address: 3962 Saltmarsh Loop, Sanford (Wyndham Preserve lot 26) Historic District: Yes No Parcel ID: 17-20-31-502-0000-0430 Residential ® Commercial Type of Work: New X Addition Alteration Repair Demo Change of Use Move Description of Work: Construction of new single family residence Plan Review Contact Person: Michelle Parkison Title: Permitting Manager Phone:407-529-3135 Fax: Email: mparkison(a per, arksquarehomes,com Property Owner Information Name Phone: Street: City, State Zip: Resident of property? : Contractor Information Name Park Square Homes/ Vishaal Gupta Street: 5200 Vineland Rd Suite 200 City, State Zip: Orlando, FL 32811 No Phone: 407-529-3000 Fax: 407-529-3001 State License No.: CRC1330351 Arch. / MJS Home Designs Architect/Engineer Information Arch. 407-629-6711 Name: Eng. / Don Bolden. Eng. Phone: Eng. 386-668-7606 Arch./ 250 N. Wymore Rd. Suite B Winter Park FL 32789 Street: Eng./ PO Box 530783, Debary FL 32753 Fax: City, St, Zip: Bonding Company: E-mail: Mortgage Lender: Address: " Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application 119 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 3•/- /8 Signature of Owner/Agent Date Vishaal Gupta Print Owner/Agent's N e 3• I- f8 Signifture pf Notary -State o Florida Date MICHELLE PARKISONx Notary Public - Stale of Florida Commission p GG 157861 My Comm. Expires Nov 5.2021 j NellmalNWaryAun. Owl er/Ag or Produced ID Type of ID 41(1-- 3.1./& Signature of Contractor/Agent Date Print Is MICHELLE PARKISON t Notary Public- Stale of Florida Commission # GG 157861 7= My Comm. Expires Nov 5, 2021E« `0 Bondod Nraph Now Ndaryllssn. Contractor/AgenTfs "Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Flood Zone: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps, Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No 2 0 APPROVALS: ZONING: UTILITIES: A 7 `4 WASTEWATER: ENGINEERING: COMMENTS: FIRE: BUILDING: Revised: June 30, 2015 Permit Application p I r 8 7-1 City of Sanford Planning and Development Services Engineering — Floodplain Management Flood Zone Determination Request Form Name: Michelle Parkison Firm: Park Square Homes Address: 5200 Vineland Road, Suite 200 City: Orlando State: FL Zip Code: 32811 Phone: 407-529-3135 Fax: Email: mparkison@parksquarehomes.com Property Address: 3962 Saltmarsh Loop Property Owner: Park Square Enterprises, LLC Parcel identification Number: 17-20-31-502-0000-0430 Phone Number: 407-529-3000 Email: The reason for the flood plain determination is: New structure Existing Structure (pre-2007 FIRM adoption) Expansion/Addition Existing Structure (post 2007 FIRM adoption) Pre 2007 FIRM adoption = finished floor elevation 12" above BFE Post 2007 FIRM adoption = finished floor elevation 24" above BFE (Ordinance 4360) OFP CIAL S O Y Flood Zone: X Base Flood Elevation: N/A Datum: N/A FIRM Panel Number: 120294 0090 F Map Date: Sept. 28, 2007 The referenced Flood Insurance Rate Map indicates the following: The parcel is in the: floodplain floodway A portion of the parcel is in the: floodplain floodway The parcel is not in the: M floodplain floodway The structure is in the: floodplain floodway The structure is not in the: floodplain floodway If the subject property is determined to be flood zone W, the best available information used to determine the base flood elevation is: BP# 18-1135 Reviewed by: Michael Cash, CFM Date: March 19, 2018 Application for Paved Driveway, Sidewalk or WalkwayIncluding Right -of -Way Use & 9 9 Y FtO1;;D9 Landscaping in Right -of -Way www.sanfordn.gov Department of Planning & Development Services 300 North Park Avenue, Sanford, Florida 32771 Phone:407.688.5140 Fax:407.688.5141 This permit authorizes work to be done on the subject property or in the City of Sanford's right-of-way in accordance with the City's regulations and the attached construction plans approved as part of this permit. The permit is required for driveway or sidewalk construction over 100 square feet of concrete or other material on the subject parcel and / or any construction of a driveway, walkway or landscape improvements within the city right-of-way. It does not approve any work within any other jurisdiction's right-of-way. All requested information below as well as a current survey, site plan or plat clearly identifying the size and location of the existing right—of-way and use shall be provided or application could be delayed. Callbetoreyouft 1. Project Location/Address: Sgt. a Or Ci 2. Proposed Activity: D Driveway El Walkway Other: 3. Schedule of Work: Stan Date Completion Date 4. Brief Description of Work: Construction of new driveway for new single family residence This application is submitted by. Rqxrtyowner- Signature: Address: 5200 Vineland Rd Suite 200 Orlando, FL 32811 Phone: (407) 529-3135 Fax: Print Name: Vishaal Gupta El Emergency Repairs Email: mparkison@parksquarehomes.com Date: 3' / ' J 8 Maintenance Responsibilities/Indemnification The Requestor, and his successors and assigns, shall be responsible for perpetual maintenance of the improvement installed under this Agreement. This shall include maintenance of the improvement and unpaved portion of nght-of-way adjacent thereto. Requestor may. with written City authorization, remove said installation/improvement fully restoring the right-of-way to its previous condition. In the event that any future construction of roadways, utilities, stornwater facilities, or any general maintenance activities by the City becomes in conflict with the above permitted activity, the permittee shall remove, relocate and/or repair as necessary at no cost to the City of Sanford insofar as such facilities are in the public right-of-way. If the Requestor does not continuously maintain the improvement and area in accordance with previously stated criteria, or completely restore the nght-of-way to its previous condition, the City shall, after appropriate notice, restore the area to its previous condition at the Requestor's expense and, if necessary, file a lien on the Requestor's property to recover costs of restoration. To the fullest extent permitted by law, Requestor agrees to defend, indemnify, and hold harmless the City, its councilpersons, agents, servants, or employ- ees (appointed, elected, or hired) from and against any and all liabilities, claims, penalties, demands, suits, judgments, losses, expenses, damages (direct, indirect or consequential), or injury of any nature whatsoever to person or property, and the costs and expenses incident thereto (including costs of defense, settlement, and reasonable attorney's fees up to and including an appeal), resulting in any fashion from or ansing directly or indirectly out of or connected with the use of the City's right-of-way. I have read and understand the above statement and by signing this application I agree to its terms. Signature. Date: This permit shall be posted on the site during construction. Please call 407.688.5080 24 hours in advance to schedule a pre -pour inspection. Pre -pour Inspection by: Date: Application No: Reviewed: Public Works Utilities Approved: Engineering V Site Inspected by: Special Permit Conditions: Official Use Only Fee: Date: Date: Date: Date: '5 - 1 9 .Z018 Date: November 2015 ROW Use Driveway.pol LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: 3. 1 • /& I hereby name and appoint: David Mercer an agent of: Park Square Homes Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): 0 The specificpermit and application for work located at: Expiration Date for This Limited Power of Attorney: la • 31. 0101A License Holder Name: Vishaal Gupta State License Number: CRC1330351 Signature of License Holder: Z -.01 STATE OF FLORIDA COUNTY OF Orange The foregoing instrument was acknowledged before me this 1 day of rYlorc,-. , 200r IPA by Vishaal Gupta who is q(personally known to me or o who has produced as identification and who did (did not) take an oath. Signature Notary Seal) 50N of Florida 157861 N.' s Nov 5. 2021 NOlary ADM. Rev. 08.12) Print or type name Notary Public - State of for Ckc,,. Commission No.GG 16-18Ca I My Commission Expires: c' c. l 44 THIS INSTRUMENT PREPARED BY AND UPON RECORDING, PLEASE RETURN TO: R. Travis Retz, Esq. GODBOLD, DOWNING, BILL & RENTZ, PA 222 W. Comstock Avenue, Suite 101 inter Park, FL 32789 I IIIIII IIIII Illf l IIIII Illll illli f III Ifll GRANT MALOY, SEMINOLE COUNTY CLERK, OF CIRCUIT COURT 6 COMPTROLLERBK. 9033 Pas 5-8 (4P9s) CLERK'S : 2017121544 RECORDED 12/01/2017 02:45:57 PMDEEDDOCTAX $5 376.00 RECORDING FEES $35.50 RECORDED BY hdevoro_ SPACE ABOVE THIS LINE FOR RECORDING DATA]--------- --- ---------- ---..--- SPECIAL WARRANTY DEED THIS SPECIAL WARRANTY DEED is made and entered into as of the 29-- day of November, 2017, by and between BRISSON INVESTMENTS, LLC, a Florida limited liability company, whose post office address is 27 North Summerlin Avenue, Orlando, FL 32801 Grantor"), to PARK SQUARE ENTERPRISES, LLC, a Delaware limited liability company, whose address is 5200 Vineland Road, Suite 100, Orlando, FL 32811 ("Grantee"). Wherever used er e & the terms "Grantor" and "Grantee" shall be deemed to include all the parties to this Specr a'I Warranty Deed and the heirs, legal representatives and assigns of individuals and the succe'ssors and assigns of corporations. The singular shall be deemed to include the plural, and vi+-fee versa, where the context so permits. TNESSETH• THAT, for and in consideration ofathe sum of Ten and No/100 Dollars ($10.00) and other good and valuable considerations, the rT,ecy.it and sufficiency of which is acknowledged by Grantor, Grantor hereby grants, bargains, sell-SCAnveys and confirms unto Grantee all that certain real property together with the improvemen;*' ?hereon (hereinafter collectively referred to as the "Real Property") in Seminole County, Florid a,oye particularly described as follows: See Exhibit "A" attached hereto and inco ikated herein by this reference. 0 TOGETHER WITH all the tenements, hereditaments appurtenances thereto belonging or in any way appertaining. TO HAVE AND TO HOLD the same unto Grantee in fee simple, forever. AND Grantor hereby fully warrants the title to the Real Property and will defend the same against the lawful claims of all persons claiming by, through or under the Grantor, but not otherwise; the foregoing subject to, real estate taxes or assessments for 2018 and the matters set forth on Exhibit "B" attached hereto and incorporated herein by this reference, all of which, by reference hereto, shall not serve to reimpose same. Book9033/Page5 CFN#2017121544 Page 1 of 4 qb IN WITNESS WHEREOF, Grantor has caused this Special Warranty Deed to be executed as of the day and year first above written. Signed, Sealed and Delivered in the Presence of: Print Name: 1 Print Name: v aA e-e -sC— NY o STATE OF FLORIDA COUNTY OF ORANGE GRANTOR: BRISSON INVESTMENTS LLC, a Florida limited liability company 0 The foregoing instrument was acknowled`gecl' 2017, by Robert Zlatkiss, as Authorized Representat limited liability company, on behalf of said entity. He as identification. ti,, rnNnsao+z wcowASSMSPOOM o Mq 15.2= eane.e nw twu r Ae euee.0.. uss Representative A. me this 2 , day of November, trisso Inv ents LLC, a Florida pally known to me r has produced Notary Public, State'-Flon Seal) Book9033/Page6 CFN#2017121544 Page 2 of 4 Exhibit "A" Legal Description Lots 19, 20, 21, 42, 43, 73, 74, 75, 76,133, 134, 135, 148 and 178, Wyndham Preserve according to the Plat thereof as recorded in Plat Book 81, Page 93, Public Records of Seminole County, Florida. Book9033/Page7 CFN#2017121544 Page 3 of 4 Exhibit "B" Permitted Exceptions Annexation Ordinance recorded October 13, 2005 in Book 5950, Page 1143. 2. City of Sanford Development Order No. 12-20 recorded August 16, 2012 in Book 7835, Page 76; re -recorded October 5, 2012 in Book 7870, Page 613; and corrected and recorded September 11, 2014 in Book 8330, Page 60. 3. Cooperation Agreement between Serengeti Properties, LLC, a Florida limited liability company and Brisson Investments LLC, a Florida limited liability company, recorded October 31, 2012 in Book 7889, Page 598 and Amendment to Cooperation Agreement recorded October 26, 2016 in Official Records Book 8793, Page 289. 4. Provisions oi iadham Preserve, recorded in Plat Book 81, Pages 93 through 102, inclusive. 5. Declaration and DedicA.;_ .of Avigation Easement and Related Covenant and Agreements recorded May 0! O17 in Book 8916, Page 1019. 6. Declaration of Covenants, C'oiis Easements and Restrictions for Wyndham Preserve recorded July 5, 2017 in Bak 8947, Page 158. 7. Memorandum of Post Closing Agreeme(recorded August 3, 2017 in Official Records Book 8965, Page 159. 8. Zoning, ordinances and/or restrictions and prohibit-1101 jimposed by governmental Authorities. CA Book9033/Page8 CFN#2017121544 Page 4 of 4 RECORD COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 043 Sorrento A RHG Bed4 Loft - N Builder Name: Park Square Homes Street: 3962 Saltmarsh Loop Permit Office: C# of Sanford City, State, Zip: Sanford , FL, Permit Number: T 8 _ 1 35 n-'ft' Owner: Park Square Homes Jurisdiction: 691500 Design Location: FL, Orlando County:: Seminole (Florida Climate Zone 2 q X. 1. New construction or existing New (From Plans) 9. Wall Types (2612.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1302.00 IF b. Frame - Wood, Exterior R=11.0 1026.00 f12 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11.0 284.67112 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (1518.0 sgft.) Insulation Area 5. Is this a worst cases No a. Under Attic (Vented) R=30.0 1518.00 ft 2 6. Conditioned floor area above grade (ft2) 2078 b. N/A R= f12 Conditioned floor area below grade (W) 0 c. N/A 11. Ducts R= f12 R 1`12 7. Windows(241.0 sqft.) Description Area a. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor 6 415.6 a. U-Factor: Dbl, U=0.55 135.00 112 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.58 64.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:16.00 c. U-Factor: Dbl, U=0.54 42.00 ft2 SHGC: SHGC=0.25 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 33.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 2.682 ft. Area Weighted Average SHGC: 0.233 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2078.0 sqft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 1324.00 1`12 b. Conservation features b. Floor Over Other Space R=0.0 560.00 ft2 None c. other (see details) R= 194.00 ft2 15. Credits Pstat Glass/Floor Area: 0.116 Total Proposed Modified Loads: 63.37 PASSTotalBaselineLoads: 66.24 1 hereby certify that the plans and specifications covered by Review of the plans and 411E STq, this calculation are in compliance with the Florida Energy specifications covered by this Code. Digitally signed byRafael calculation indicates compliance 4j iq,'' =E,•',, + Rafael Izquierdo 12Quierdu with the Florida Energy Code. Uatr 2018 03.01 WW 16 -05'00' PREPARED BY: i Before construction is completed DATE: this building will be inspected for a compliance with Section 553.908 I hereby certify that this buildin , as designe , is in compliance Florida Statutes. j, C with the Florida Energy C OD tNE OWNER/AGEN BUILDING OFFICIAL: a DATE: DATE: 04 AW9 Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. 3/1/2018 9:07 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: Lot 043 Sorrento A RHG Bed Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 2078 Lot # 43 Owner Name: Park Square Homes Total Stories: 2 Block/Subdivision: WP of Units: 1 Worst Case: No PlatBook: Builder Name: Park Square Homes Rotate Angle: 0 Street: 3962 Saltmarsh Loop Permit Office: City of Sanford Cross Ventilation: No County: Seminole Jurisdiction: 691500 Whole House Fan: No City, State, Zip: Sanford , Family Type: Single-family FL , New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Orlando FL_ORLANDO INTL_AR 41 91 70 75 526 44 Medium BLOCKS Number Name Area Volume 1 Blockl 2078 19099.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1 st Floor 1324 12313.2 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 754 6786 No 3 3 1 Yes Yes Yes FLOORS 1r Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Floor over Garage 2nd Floor ---- ---- 194 ft2 11 0.29 0 0.71 2 Slab -On -Grade Edge Insulatio 1 st Floor 139.5 ft 0 1324 Hz 0.29 0 0.71 3 Floor Over Other Space 2nd Floor ---- 560 ft2 0 0.29 0 0.71 ROOF J Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Absor. Tested Tested Insul. deg) 1 Hip Composition shingles 1698 ftz 0 f12 Dark 0.9 N 0.9 No 0 26.6 ATTIC J Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1518 ft= N N 3/1/2018 9:07 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FnRM Rdf16-9(Y17 CEILING Y Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) 1st Floor 30 Blown 1518 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo* wOrntTnWallTypeSpace 1 N Exterior Frame - Wood 2nd Floor 11 30 0 9 0 270.0112 0 0.25 0.8 0 2 N Exterior Concrete Block - Int Insul 1 st Floor 4.1 10 0 9 4 93.3 ft2 0 0 0.8 0 3 E Exterior Frame - Wood 2nd Floor 11 27 0 9 0 243.0 W 0 0.25 0.8 0 4 E Exterior Concrete Block - Int Insul 1st Floor 4.1 55 0 9 4 513.3 ft2 0 0 0.8 0 5 S Exterior Frame - Wood 2nd Floor 11 30 0 9 0 270.0 ft2 0 0.25 0.8 0 6 S Exterior Concrete Block - Int Insul 1st Floor 4.1 30 0 9 4 280.0 f12 0 0 0.8 0 7 W Exterior Frame - Wood 2nd Floor 11 27 0 9 0 243.0 ft2 0 0.25 0.8 0 8 W Exterior Concrete Block - Int Insul 1st Floor 4.1 44 6 9 4 415.3 ft2 0 0 0.8 0 9 Garage Frame - Wood 1 st Floor 11 30 6 9 4 284.7 ft2 0 0.25 0.8 0 DOORS A Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated 1st Floor None 39 3 8 24112 2 Wood 1st Floor None 39 2 8 8 21.3112 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Low-E Double Yes 0.55 0.22 N 15.0 W 1 it 0 in 1 it 4 in Drapes/blinds None 2 n 1 Metal Low-E Double Yes 0.54 0.25 N 12.0 ft2 1 it 0 in 1 1t 4 in Drapes/blinds None 3 e 3 Metal Low-E Double Yes 0.55 0.22 N 15.0 IF 1 It 0 in 1 it 4 in Drapes/blinds None 4 e 3 Metal Low-E Double Yes 0.54 0.25 N 12.0 f12 1 ft 0 in 1 it 4 in Drapes/blinds None 5 e 4 Metal Low-E Double Yes 0.55 0.22 N 15.0 ft2 1 It 0 in 1 it 4 in Drapes/blinds None 6 e 4 Metal Low-E Double Yes 0.54 0.25 N 8.0 112 1 It 0 in 11 116 in Drapes/blinds None 7 e 4 Metal Low-E Double Yes 0.54 0.25 N 6.0 ft2 1 It 0 in 11 ft 6 in Drapes/blinds None 8 s 5 Metal Low-E Double Yes 0.55 0.22 N 15.0 f12 1 it 0 in 1 it 4 in Drapes/blinds None 9 s 5 Metal Low-E Double Yes 0.54 0.25 N 4.0 f12 1 It 0 in 1 it 4 in Drapes/blinds None 10 s 6 Metal Low-E Double Yes 0.55 0.22 N 30.0 ft2 1 It 0 in 1 ft 4 in Drapes/blinds None 11 s 6 Metal Low-E Double Yes 0.58 0.25 N 64.0 f12 7114 in 1 it 4 in None None 12 W 8 Metal Low-E Double Yes 0.55 0.22 N 30.0 f12 1 It 0 in 1 114 in Drapes/blinds None 13 W 8 Metal Low-E Double Yes 0.55 0.22 N 15.0 ft2 1 it 0 in 11 ft 6 in Drapes/blinds None 3/1/2018 9:07 AM EnergyGaugeS USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 GARAGE it Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 420 ft2 420 f12 54 ft 9.3 ft 1 INFILTRATION Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000409 2228.2 122.33 230.05 .3674 7 HEATING SYSTEM ff System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF.9 33 kBtu/hr 1 sys#1 COOLING SYSTEM p System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 34.8 kBtu/hr 1044 cfm 0.75 1 sys#1 HOT WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart 11 Company Name Collector Storage System Model ft Collector Model it Area Volume FEF None None ft2 DUCTS v # Supply --- Location R-Value Area Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 415.6 ft 2nd Floor 103.9 ft Prop. Leak Free 2nd Floor --- cfm 62.3 cfm 0.03 0.50 1 1 3/1/2018 9:07 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingII ]] Jan HeatinrX1 Jan II jj Feb jX] Feb jj jj Mar jX] Mar f A r Apr jj j jj Ma j May IIJ Jun un jX Jul j] Jul Xj Au 41AujfX] Se Sep j ] Oct Oct j Nov j Nov Dec Dec Ventin ` ] Jan jj Feb X) Mar A r JJ Ma Jun 1 Jul Aug I) Se X1 Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling ( WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling ( WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating ( WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating ( WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/ 1/2018 9:07 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 3962 Saltmarsh Loop Permit Number: Sanford , FL, MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air Ieakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 3/1/2018 9:07 AM EnergyGauge® USA - FlaRes2017 - FBC 61h Edition (2017) Complia Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC-raled and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psi (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 controls. SECTION R403 SYSTEMS R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or 7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(1), (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test. Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping Insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or below 55°F (13°C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 3/l/2018 9:07 AM EnergyGauge® USA - FlaRes2017 - FBC 61h Edition (2017) Complian Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend o1 at least 31/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 606C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3• If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (it split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM) MINIMUM EFFICACY a CFM/WATT) AIRFLOW RATE MAXIMU CFM) Range hoods Any 2.8 cim/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt 90 Bathroom, utility room 90 2.8 clm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 3/1/2018 9:07 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (100C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40OF (4.80C). R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the healer. Operation of such swatch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 3/1/2018 9:07 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verity procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandator9)he energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 3/1/2018 9:07 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 96 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft-) 7. Windows" Description a. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.58 SHGC: SHGC=0.25 c. U-Factor: Dbl, U-0.54 SHGC: SHGC=0.25 d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 3962 Saltmarsh Loop, Sanford, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1302.00 ft2 b. Frame - Wood, Exterior R=11.0 1026.001t 1 c. Frame - Wood, Adjacent R=11.0 284.671t2 4 d. N/A R. ft2 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 1518.00 ft2 2078 b. N/A R. 1t2 c. N/A R= ft2 Area Ducts R ft2 135.00 ft2 a. a. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor 6 415.6 64.00 ft2 12. Cooling systems kBtu/hr Efficiency 42.00 112 a. Central Unit 34.8 SEER:16.00 ft2 2.682 ft. 0.233 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1324.00112 b. Floor Over Other Space R=0.0 560.00 ft2 c. other (see details) R= 194.00 ft2 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code complia eatu . Builder Signature: Date: J Address of New Home: (oa rs ( City/FL Zip: kBtu/hr Efficiency 33.0 HSPF:9.00 Cap: 50 gallons EF: 0.9 Pstat tOE Sri c a OD WE Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport a@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/1/2018 9:07 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 t SecProSummary Job: Lot 043 Sorrento ARHG B... wrightsoft` ry Date: 05/20/2017 Entire House By. LF/RI/AT One Stop Cooling and Heating 7225 Sardscove Cont. Wirter Park FL 32792 Phone: (407) 629.6920 Fax: (407) 629.9307 Web: vAmOreStopCoolirg com License CAC032444 Project Information For: Park Square Homes 3962 Saltmarsh Loop, Sanford, FL Notes: psinn Infinrmafia Weather: Orlando Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 92 OF Inside db 68 OF Inside db 74 OF Design TD 26 OF Design TD 18 OF Daily range M Relative humidity 50 Moisture difference 49 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20573 Btuh Structure 19587 Btuh Ducts 2266 Btuh Ducts 4681 Btuh Central vent (0 cim) 0 Btuh Central vent (0 ctm) 0 Btuh none) none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22839 Btuh Use manufacturer's data n Rate/swin multi ier 0.97 BtuhInfiltrationEquipmensensleload23637 Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4048 Btuh Ducts 971 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg none) Area (ft 2117 2M Equipment latent load 5019 Btuh Volume (ft3) 19452 19452 Air changes/hour 0.41 0.21 Equipment Total Load (Sen+Lat) Req. 0.75 SHR 28657 2.6 Btuh tonEquiv. AVF (cfm) 133 68 total capacity at Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR6036H1 Cond 4TWR6036H1 AHRI ref 7562981 Coil TEM6A0C36H31++TDR AHRI ref 7562981 Efficiency 9 HSPF Efficiency 13.0 EER,16 SEER Heating Input Sensible cooling 26100 Btuh Heating output 33000 Btuh @ 47°F Latent cooling 8700 Btuh Temperature rise 0 OF Total cooling 34800 Btuh Actual air flow 0 cfm Actual air flow 1160 cfrn Air flow factor 0 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 32 OF Calculations approved byACCAto meet all requirements of Manual J 8th Ed. t wri_ghtsof[' 2018-Mar-010853:14PageRighlSule®Uriversa12018 18A.08 RSU16202 L Temp\Lot 043 Sorrerto A RHG Bed4 Loft - N.rtp Calc = MM Frort Door laces: N 1 wrightsoft' Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove CoA Wafer Parr FL 32792 Phone: (407) 629. 6920 Fax: (407) 629 - 9307 Web: wawOneStopCoolirg oom License: CA0032444 Job: Lot 043 Sorrento A RHG Bed4 ... Date: 05/20/2017 By. tF/RI/AT 1 Room name Entire House PWDR 2 Exposed wall 2535 ft 12D 11 3 Room height 92 ft d 9.3 ft heaVoDol 4 Room dimensions 45 x 75 It 5 Room area 21173 1F 33.8 IP Ty Consrumon number U-value Bbrh4F g Or HTM Btuh" Area (Ili or perimeter (ft) Load Bluh) Area (Il2) or perimeter (It) Load BWh) Heat Cool Gross NIPS Heat Cool Gross NiP/S Heat Cod 6 Vjl 1213-0sw 4A5-20m 4B5-21m OD97 0550 0540 n n n 2S3 1435 14.09 2.82 13.41 13S7 270 15 12 243 0 0 615 215 169 685 201 164 0 0 0 0 0 0 0 0 0 0 0 0 tqI 13A-401s 0.143 n V3 2.90 93 69 258 200 42 42 156 121 11 L--_0 11 DO 0" n 10.18 1227 24 24 244 294 0 0 0 0 Vy G 12B-0sw 4A5-2om 4B5-21m 0A97 0550 0540 a a a 253 1435 14.09 2M 27.44 29.62 243 15 12 216 0 0 547 215 169 609 412 355 0 0 0 0 0 0 0 0 0 0 0 0I--G 4A5-20m 0.143 0550 a a 3.73 1435 2.90 27.44 512 15 483 0 1801 215 1397 412 70 0 66 0 245 0 190 0TE 13A-4ocs 4B5.21m 4B5-2tm 1213-09m 0540 0540 0.097 a a s 14.09 14.09 253 29.62 29.62 2.82 8 6 270 0 0 251 113 85 635 237 178 707 4 0 0 0 0 0 56 0 0 118 0 0 C 4A5-2om 4B5-21rn 0550 0540 s 5 1435 14.09 13b1 13.67 15 4 12 4 215 56 204 55 0 0 0 0 0 0 0 0C VpI 13A-4om 4A5.2om 4A5-2omd 0.143 0550 05W s s s 3.73 1435 M14 2.90 13Z1 15,90 279 30 64 185 25 64 690 431 969 536 408 1018 0 0 0 0 0 0 0 0 0 0 0 0 1--- II-- 2 W y! 12B-0%N 13A-4ocs 4A5-torn 0A97 0.143 O55D w w w 2S3 3.73 1435 2.82 2.90 27.44 243 414 30 243 369 0 615 1377 431 685 1068 823 0 0 0 0 0 0 0 0 0 0 0 0f. 4A5-20m _ 12C-096v 11DO 16B-30ad 0550 0A91 03M 0A32 w n 1435 238 10.18 0.84 27.44 151 1227 1.76 15 284 21 1517 0 262 21 1517 215 623 217 1267 412 395 262 2668 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P LD C F 19C-19= 0A49 0.44 031 194 194 86 60 0 0 0 0 F 22A-Oxn _ 1,18D 30.80 0.00 1324 140 4296 0 34 12 370 0 6 0) AED excursion 0 13 Ernelope lossfon 16771 14444 828 443 12 a) IrMlMon 3802 1373 183 66 b) Room eenfilabon 0 0 0 0 13 Internal gains: Occupants @ 230 9 2070 0 0 Applianoesbther 1700 0 Subtotal (lines 6 to 13) 20573 19587 1010 509 Less external load 0 0 0 0 Len trarder 0 0 0 0 Redistribution 0 0 875 467 14 Subtotal 20573 19587 1885 976 15 Dud loads I 11% 24%1 2266 4681 11% 24% 208 233 Trial room load I I 228391 24268 2093 1210 Air required (dm) 0 1160 0 58 Calculations approved NACCAto meet all requirements of Manual J 8tf1 Ed. f wr`gtr+tsoft- 2018-Mar-01085314 AM Rigl*Suie®Uriversal 2018 18.0.08 RSU16202 Page 1 L Temp%Lol 043 Sorrerw A RHG Bed4 Loft- N rap Cale - MJ8 Frori Door faces: N wrightsofr Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Coati W irter Park FL 32792 Phone, (407) 629.6920 Fax: (407) 629 - 9307 Web- wwwOneStopCoohrg com License: CAC032444 Job: Lao 043 Sorrento ARHG Bed4 ... Date: 05/20/2017 By: LF/RI/AT 1 Room name STC1 WDY 2 Exposadwell 17.0 f1 0 If 3 Room height 93 fi heaUmN 9.3 f1 heaV000lol 4 5 Room dimensions Room area 45 x 17.0 11 765 W 6.0 x 75 1t 45D W Ty Construction number U-value BWW`F) Or HTM BWh" Area (8) or perimeter (it) Load BWh) Area (W) or perimeter (f1) Load BWh) Heat Cool Gross NiP/S Heat Cod Grass NPS Heat Cod 6 1213-09w 4A5.20m 4BS2fin O.097 0550 0540 n n n 2.53 1435 14 09 2.82 13AI 13b7 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 11 r D 13A-flocs 11 DO 0.143 03W n n 3.73 10.18 2.90 1227 0 0__ 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 12B-0s6y 4A5.2om 4B5-2kn UP 0550 0540 a a a 253 1435 14A9 2.82 27.44 29.62 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A4ocs 4A5.2om 0.143 0550 a a 3.73 1435 2.90 27.44 158 0 152 0 568 0 440 0 0 0 0 0 0 0 0 0 v^ GG 48S21rn 4BS2hn 12B-0sw 0540 0540 O.097 a e s 14.09 14.09 253 29.62 29.62 2.82 0 6- 0 0 0 0 0 85 0 0 178 0 0 0 0 0 0 0 0 0 0 0 0 01l C 4A5-2om 4B5-2trn 0550 0540 s s 1435 14.09 13.61 13.67 0 0- 0 0- 0 0_ 0 0- 0 0 0 0 0 0 0 0C G 13A-4ocs 4A5.2om 4A5-2omd 0.143 OS% 05M s 5 s 3.73 14.35 15.14 2.90 13.61 15.90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0C W 12B-09w 13A-4a5 4A5.2om O.097 0.143 0550 w w w 253 3.73 1435 2.82 2.90 27.44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5.20m 12C-096Y 11D0 168-30ad 05W 0.091 0" O.032 w n 1435 238 laiS 0.84 27.44 151 1227 1.76 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 56 21 0- 0 34 21 0 0 82 217 0 0 52 262 0 P L-D C F 19C-19mcp O.049 0.44 031 0 0 0 0 0 0 0 0 F 22A-tom , 1.180 30.80 OAO 77 17 524 0 45 0 0 0 6 c) AED excursion 20 23 Envelope lossoWn 1176 638 299 291 12 a) Infiltration 259 93 0 0 b) Room %entlaton 0 0 0 0 13 Intemalgams Oocupanls@ 230 0 0 0 0 Apphancesbther 0 500 Subtotal(lines 6to13) 1435 732 299 791 Low external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 1435 732 284 183 14 Subtotal 0 0 583 973 15 Duct bads I 11% 24%1 0 0 11% 24% 64 233 Total room load 0 0 647 1206 Air required (dm) 0 0 1 0 58 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 10-`ghtsoTt- 2018-Mar-01085314 cA Riglt-Suta®Unversal 201818.0.08 RSU16202 Page 2 L TempIo1043 SorrertoA RHG Bed4 Loft- N nq Calc a KM Frort Door laces N wrightsofr Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sardsouve Cotn Winter Park FL 32792 Phone: (407) 629 - 6920 Fax, (407) 629.9307 Web: wmmOreSlopCoolirg com License' CAC032444 Job: Lot 043 Sorrento ARHG Bed4 ... Date: 05/20/2017 By. LF/RI/AT 1 Room name Krr DNE 2 Exposed wall 105 ft 95 ft 3 Room height 93 4 heattool 93 ft heaVmol 4 Room dimensions 14.0 x 105 ft 1 A x 147D ft 5 Room area 147D IF 147D W Ty Construtrion number U-%Wue BWhRF n Or HTM fth" Area (W) or perimeter (ft) Load Bluh) Area (W) or perimeter (ft) Load Bluh) Heat Cod Gross NWP/S Heat Cod Gross NiP/S Heat Cod 6 Vy 1213 9w OA97 n 2S3 2,82 0 0 0 0 0 0 0 0 WSW n 1435 13A1 0 0 0 0 0 0 0 0fC44AS-20m 852trn 0540 n 14.09 1367 0 0 0 0 0 0 0 0 0.143 n V3 2.90 0 0 0 0 0 0 0 0 1. 13A-4as 11 11 DO 03,% n 10.18 1227 0 0 0 0 0 0 0 0 y 1213-0svu OA97 a 2.53 282 0 0 0 0 0 0 0 0 G 4A5-2om 0550 a 1435 27.44 0 0 0 0 0 0 0 0 l 4135-21m 0540 e 14.09 29.62 0_ 0 0 0 0 0 0 0 V i13A4ors4A5-20m 0.143 0550 a a V3 1435 2.90 27.44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 485.21rn 485.21m 0540 0540 a a 14.09 14.09 29.62 29.62 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12B-0s v 0.097 s 253 282 0 0 0 0 0 0 0 0 4AS-2om 0550 s 1435 13.61 0 0 0 0 0 0 0 0 485.21m 0540 s 14.09 13.67 0 0 0 0- 0 0 0 0 W 13A-4ors 0.143 s 73 2.90 0 0 0 0 0 0 0 0 4A5.2om 0550 s 14.35 13.61 0 0 0 0 0 0 0 0 fi 4A5-2omd 0560 s 15.14 15.90 0 0 0 0 0 0 0 0 W- 12B-0s6v OD97 w 253 282 0 0 0 0- 0- 0 0 0 13A-4ors 4A5-2om 0.143 0550 w w 73 1435 2.90 27.44 98 0 98 0 364 0 283 0 88 0 73 0 274 0 212 0 I=2 4A5.2om 12C-09w 11DO 0550 OA91 039D w n 1435 238 10.18 27.44 151 1227 0 130 0 0 130 0 0 309 0 0 196 0 15 0 0 0 0 0 215 0 0 412 0 0 PI - r--D C 16B-30ad 0A32 0.84 1.76 0 0 0 0 56 56 47 98 F 19C-19cscp 0A49 0.44 031 0 0 0 0 0 0 0 0 F - 22A-tDm 1.180 3080 OAO 147 11 323 0 147 10 293 0 6 c) AED exclusion 49 152 Envelope losstain 997 430 828 875 12 a) Infiltration 160 58 145 52 b) Room %enblabon 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliancesblher 120D 0 SubblalPines 6to13) 1157 1687 973 927 Less external load 0 0 0 0 LesstrarkSler 0 0 0 0 Redistribution 63 41 113 73 14 Subldal 1220 1728 1086 1000 15 Dud loads I 11% 24%1 134 413 11% 249% 120 239 Total room load I I 1354 2141 1 1206 1239 Air required (dm) 0 102 1 0 59 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. f wrlglsrsoTt- 2018-Mar-010853:14 At & Right-SU190Universal 2018 18.0.08 RSU16202 Page 3 L Temp1Lo1043 SorrenioA RHG Sed4 Loft- NJup Calc. MJB Frorl Door laces: N wrightsoftRight-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Cott W irter Park FL 32792 Phore: (407) 629 - 6920 Fax, (407) 629.9307 Web. wwwOreStopCoohrg com License: CA0032444 Job: Lot 043 Sorrento A RHG Bed4 ... Date: 05/20/2017 By. LF/RI/AT 1 Room name GRT WED 2 Exposedvdl 325 4 395 ft 3 Room height 93 ft heaV000l 93 4 heaVcod 4 5 Room dimensions Room area 1. 0 x 2815 ft 2815 W 145 x 175 ft 253. 8 W Ty Coratrucdon number U- value BWhA - 9 Or HTM BWh*) Area ( It) or perimeter (ft) Load BWh) Area ( II) or perimeter (ft) Load BWh) Heat cod Gross NP S Heat Cod Gross NAS Heat cool 6 12B-09N 4A5- 20m 4B5- 21m 0A97 0550 05Q n n n 253 1435 14. 09 2. 82 13A1 13. 67 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 t 1 yI 0 13A- 4oce 11 DO 0, 143 0390 n n V3 10. 18 2. 90 1227 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 Vjl 2 12B- 0sw 4A5. 2om 4B5- 2Im 0. 097 0550 0S40 a a a 253 1435 14. 09 2. 82 27. 44 29. 62 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 s 4A5- 2om 0. 143 0550 a a 3. 73 14. 35 2. 90 27. 44 0 0 0 0 0 0 0 0 0 163 15 148 0 551 215 428 412 TE13A- 4o 4B5- 21m 4135. 2trn 12B- 09w 0. 540 0540 OD97 a a s 14. 09 14. 09 253 29. 62 29. 62 zw 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5- 20m 41215- 21n 0550 0540 s s 1435 14. 09 13S1 13. 67 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 13A- 40CS 0.143 s 3.73 2.90 144 80 299 232 135 105 391 304 4A5- 20m 0S50 s 1435 13b1 0 0 0 0 30 25 431 408 l 4A5-2omd 0580 s 15.14 15.90 64 64 969 1018 0 0 0 0 W y! 1213- 09w , 13A- 4as 4AS20m 0. 097 0. 143 0550 w w w 253 3. 73 1435 2. 82 2. 90 27. 44 0 158 30 0 128 0 0 478 431 0 371 823 0 70 0 0 70 0 0 260 0 0 202 0 24A5-20m 12C- 09w 11 DO 0550 OD91 03M w n 1435 238 10. 18 27. 44 151 1227 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 R C 16630ad OA32 0.84 1.76 282 282 235 495 254 254 212 446 F 19c-19cscp 0A49 0.44 031 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 30.80 OAO 282 33 1001 0 254 40 1217 0 6 c) AED excursion 82 82 Envelope lossrgain 3413 3021 3278 2118 12 a) tr ftbon 495 179 601 217 b) Room ventlabon 0 0 0 0 13 Inlernal gains Ooaupaft @ 230 0 0 2 460 Applianoesbtlwer 0 0 Subtotal pines 6Io 13) 39D7 3200 3879 2795 Len external load 0 0 0 0 Len transfer 0 0 0 0 Redistribubon 0 0 0 0 14 Subtotal 3907 3200 3879 2795 15 Duct loads 1 11% 24%1 430 765 11% 24% 427 668 Total room load I 1 1 4338 3964 4306 3463 Air required (dm) 0 189 1 1 0 166 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1*- wrt0I'T-=4w1't- 2018-Mar-010853.14 RigtFStiteODUnversal 201818.0.08 RSU16202 Page 4 L Temptlot 043 Sorrerto A RHG Bed4 Loft- N rtp Calc =" Frort Door laces N wrightsofr Right-JO Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Court Wirter Park FL 32792 PhDre: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCoolirg oom License: CAC032444 Job: Lot 043 Sorrento ARHG Be& ... Date: 05/20/2017 By. LF/RI/AT 1 Room name MTOI METH 2 Exposed well 0 h 13.0 h 3 Room height 93 h heattool 93 h heaV000l 4 5 Room dimensions Room area 35 x 6.0 h 21 A IF 65 x 13.0 h 84.5 1P Ty Construction U-value Or HTM Area (flz) Load Area (It) Load number Bb1hW-*g I or perimeter (h) Bbrh) or perimeter (ft) Bbrh) Heat Cod Gross NAS Heat Cod Gross NAS Heat Cod 6 Vjl 12B•O96v O.097 n 2.53 2.82 0 0 0 0 0 0 0 0 4A5.2om 05W n 14.35 13.41 0 0 0 0 0 0 0 0II--- fCi 4135-21m O-W n 14.09 13.67 0 0_ 0 0 0 0 0 0 W 13A-flocs 0.143 n 3.73 2.90 0 0 0 0 0 0 0 0 11 L-D 11 DO 0.3W n 10.18 1227 0 0 0 0_ 0 0 0 0 12B-0av OD97 a 2.53 282 0 0 0 0 0 0 0 0 4AS-2om 05W a 1435 27.44 0 0 0 0 0 0 0 0 485.21m 0540 a 14M 29.62 0 0 0 0_ 0 0 0 0 G 13A-4oas 0.143 a 3.73 2.90 0 0 0 0 121 117 436 339 4A5-2om 05W a 1435 77.44 0 0 0 0 0 0 0 0 II-G 48S2hn 0540 a 14.09 29.62 0 0 0 0 4 0 56 118 4135-21m _ O.540 e 14.09 29.62 0 0- 0 0 0 0 0 0 1213-0sw 0.097 s 253 2.82 0 0 0 0 0 0 0 0 4A5-2om 41215-21irn _ 0550 O.540 s s 1435 14.09 13.61 13A7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Vj! G 13A-4oc s 0.143 s 3.73 2.90 0 0 0 0 0 0 0 0 4A5-2om 0550 s 14.35 13.61 0 0 0 0 0 0 0 0 G 4A5-2omd, 0580 s_ 15.14 15.90 0 0 0 0 0 0 0 W y/ G 12B-09N 13A-4oce 4AS2om O. 097 0. 143 0550 w w w 253 3. 73 14.35 282 2. 90 27.44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G R LD 4A5- 20m 12C-09w 11DO 0. 550 OA91 0390 w n 1435 238 1( 118 27.44 151 1227 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 168. 30ad O.032 084 1.76 21 21 18 37 68 68 57 120 F 19C• 19cscP O.049 0.44 031 0 0 0 0 0 0 0 0 F _ 22A- tom 1.180 3080 0.00 21 0 0 0 85 13 400 0 6 c) AED excursion 1 8 Envelope lossrgmn 18 36 950 586 12 a) btbllrabon 0 0 198 71 b) Room wifilalion 0 0 0 0 13 Internalorm O=parns@ 230 0 0 0 0 Applianoesttw 0 0 Subtotal (lines 6 b 13) 18 36 1148 657 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 759 393 14 Subtotal 18 36 1907 1050 15 DuCloads I11% 24%1 2 9 11% 24% 210 251 Trial room load 19 44 1 2117 1301 Air required ( dm) 0 2 10 62 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 wr grstsoTe- 2018-Mar-010853:14 At& Riga- Sute®Uriversal 2018 18.0.08 RSU16202 Page 5 L TempIol043 SorrerfpA RHG Bed4 Loh - Krup Cale - MR Fror1 Door faces: N wrightsoft, Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Court Wirier Park, FL 32792 Phone: (407) 629.6920 Fax: (407) 629.9307 Web: wwwOreStopCoolirg com License' CA0032444 Job: Lot 043 Sorrento ARHG Bed4 ... Date: 05/20/2017 By. LF/RI/AT 1 Room name MWIC H 2 Exposed %ell 0 A 55 11 3 Room height 93 it heal0cnd 93 11 heaVood 4 5 Room dimensions Room area 1.0 x 602 11 60.9 fF 1.0 x 1722 11 1722 W Ty Construction number U-value BWhA g Or HTM BWW Area (W) or perimeter (It) Load BAJh) Area M or permeter (11) Load BWh) Heal Cool Gross NAPS Heat Cool Gross NPIS Heal Cod 6 12B-09N 4AS-20M 4B5-21n OD97 0550 0540 n n n 2.53 14.35 14.09 2.82 13.41 13b7 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 11 Vy 13A-4- 11 DO 0.143 0390 n n 3.73 10.18 2M 1227 0 0 0 0 0 0 0 0 51 24 27 24 101 244 79 294 12B-09w 4A5-2om 4B5.21m OD97 0550 0540 a a a 253 1435 14.09 2.82 27.44 29.62 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-4ors 4A5.2om 0.143 0550 a a 3.73 14.35 2.90 27.44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5.21m 4B5-2trn 12B-Osw 0540 0540 0.097 a a s 14.09 14.09 253 29.62 29.62 2.82 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Vjl f 4A5.2om 485-2lm 0550 0.540 s s 1435 14.09 13.61 13.67 0 0 0 0 0 0 0 0 0 0, 0 0 0 0 0 0TC Vj! I-: 13A-4ocs 4ASS-20m 4A5-2omd 0.143 0550 0580 s s 5 a73 1435 15.14 2.90 13.61 15.90 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 W V613A-4o04 12B-09N 4A5.2om 0.097 0.143 0550 w w w 2M 3.73 1435 2.82 2.90 27.44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5.20m 12C-09w 11D0 16B-30ad 0550 OA91 0" OA32 w n 14.35 238 10.18 084 27.44 151 1227 1.76 0 0 0 43 0 0 0 43 0 0 0 36 0 0 0 76 0 98 0 0 0 98 0 0 0 232 0 0 0 147 0 0 R C F 19C-19c %P 0.049 0.44 031 0 0 0 0 0 0 0 0 F 22A-Iom 1.180 30.80 0.00 61 0 0 0 173 6 169 0 6 c) AED excursion 2 16 Emoelope lossrgain 36 74 747 5(34 12 a) Infiltration 0 0 84 30 b) Room wntilabon 0 0 0 0 13 Intemalgains Omrpants@ 230 0 0 0 0 Applianoerrot er 0 1 0 Subtotal pines 6 to 13) 36 74 831 535 Low exlemalload 0 0 0 0 Lesstrarafer 0 0 0 0 Redistribution 171 110 831 535 14 Subtotal 207 184 0 0 151 Duciloads ll% 24%1 23 44 11% 24% 0 0 Total room load 230 228 0 0 Air required (dm) 0 11 1 1 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrr gt+tsoft- 2018-Mar-010853:14 AE•-zc " "' """^'^-' Righ-SuteOUnversal 201818.0.08 RSU16202 Page 6 L Temp%ol043 SorrerwA RHG Bed4 Loft - Nnp Cale a" Frort Door laces N wrightsoft' Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Court. Wirier Park, FL 32792 Phone: (407) 629. 6920 Fax. (407) 629. 9307 Web' wwwOreStopCooling oom License: CAC032444 Job: Lot 043 Sorrento ARHG Bed4 ... Date: 05/20/2017 By. LF/RI/AT 1 Room name BED2 BED3 2 E wan 25D 11 25.0 ff 3 Room height 9.0 f1 heat/mol 9.0 11 heakool 4 5 Room dimensions Room area 135 x 115 ff 1553 Ili 1.0 x 164.0 It 164D Its Ty number 1v -F) value Q Btuh*) orHTM perimeetter (11) LoW BUrh) or perimeetter (II) Load BGrh) Heat Cool Gross NrP/S Heat Cool Gross NrPIS Heat Cod 6 V)I IL-- 12B-0sw 4A5-20m 485.21m 0.097 0550 0540 n n n 2S314. 35 14. 09 2. 82 13. 41 13S7 0 0 0 0 0 0 0 0 0 0 0 0 99 15 0 84 0 0 213 215 0 237 201 0 11 Vy D 13A- 4 11 DO 0. 143 0390 n n- 3. 73 10. 18 2. 90 1227 0 0 0 0 0 0 0 0 0 0 0- 0 0 0 0 12B- 09m 4A5. 2om 4B5. 21m 0A97 05M 0540 a a a 253 1435 14. 09 2. 82 27. 44 29. 62 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A- 4o s 4A5. 20m 0. 143 0550 a a a73 14. 35 2. 90 27. 44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TE 4BS2hn 4B5- 2hn 12B- 09w O- W 0540 OA97 a a s 14. 09 14. 09 253 29. 62 29. 62 2. 82 0 0_ 122 0 0 107 0 0 270 0 0 300 0 0 0 0 0__ 0 0 0 0 0 0 0 V F 4A5.2om 4B5- 21n. US% 0. 540 s s 14. 35 14. 09 13b1 13S7 15 0 12 0 215 0 204 0_ 0 0 0 0._ 0 0 0 0 G CG 1pr 13A-4= 4AS20m 4A5- 2omd 0. 143 0550 0580 s s s 3. 73 14. 35 15. 14 2. 90 13. 61 15. 90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TC' W 12B-0sw 13A- 4ocs 4A5S2om 0A97 0. 143 o550 w w w 2. 53 3. 73 1435 282. 2. 90 27. 44 104 0 0 104 0 0 262 0 0 292 0 0 126 0 0 126 0 0 319 0 0 355 0 0 I= i 4A5.20m 12C- 09v 11 DO 168. 30ad 0. 550 OA91 0" 0. 032 w n 14M 238 10. 18 0, 84 27. 44 151 1227 1. 76 0 0 0 155 0 0 0 155 0 0 0 130 0. 0 0 273 0 0 0 164 0 0 0 164 0 0 0 137 0 0 0 288 P L-- 0 C F 19C-19rscp 0.049 0.44 031 0 0 0 0 99 99 44 31 F. 22A•tDM 1.180 30.80 OAO 0 0 0 0 0 0 0 0 6 c) AED excursion 36 42 Ernelope lossrgain 877 1033 928 1070 12 a) Infiltration 368 133 368 133 b) Room wnOlation 0 0 0 0 13 Intarnal gains: Omuparns@ 230 1 230 1 230 Appliancesrother 0 0 Subtotal ( lines 6 to 13) 1245 1396 1296 1433 Less external load 0 0 0 0 Less transler 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1245 1396 1296 1433 15 Dud loads 1 11%, 24%1 137 334 11% 24% 143 343 Total room load I I 1382 11730 1439 1776 Air required (dm) 0 83 1 1 0 85 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. A} t = 221 rS4 - 2018-Mar-01 0853:14 8K '"""" RigN•Sute4DUriversal 201818.0.08 RSU16202 Page 7 L TempIot 043 Sorrerto A RHG Bed4 Loft- N rup Cale KMFrori Door laces: N wrighttsoft* Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Court Wirser Park, FL 32792 Phore: (407) 629 - 6920 Fax: (407) 629.9307 Web. wAw0reStopCoolirg com License: CAC032444 Job: Lot 043 Sorrento A RHG Bed4 ... Date: 05/20/2017 By. LF/RI/AT 1 Room name TOP BEN 2 Exposed Nell 75 ft 245 11 3 Room height 9.0 D heaV=l 91) f1 heaU000l 4 5 Room dimensions Room area 6.0 x 6.0 tt 36.0 fF 1.0 x 137D f1 137.0 W Ty U-value Or HTM Area (fF) Load Area (W) Load number BRA MIL- BWh4F) or perimeter (I) Btuh) or perimeter (4) Bhuh) Heal Cool Gross NAPSS Heal Cod Gross NAPS Heat Cod 6 1213-09N 4A5-2om Q5-21m 0.097 0550 0540 n n n 253 1435 14A9 2.82 13A1 13.67 54 0 6 48 0 0 122 0 85 135 0 82 117 0 6 111 0 0 281 0 85 313 0 82 G 1--G 11 y1 L-D 13A-40cs 11 DO 0.143 0.390 n n 3.73 10.18 2.90 1227 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12B-09N 4A5-2om 4B5.2kn OA97 0550 0.540 a a a 2.53 1435 14.09 2.82 27.44 29.62 0 0 0 0 0 0 0 0 0 0 0 0 104 15 0 89 0 0 224 215 249 412 0 yl C 13A-4ocs 4A5-20m 0.143 05W a a 3.73 14.35 2.90 27.44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G Imo' 4BS21m 4135.21n 128-09w 0540 0.540 0.097 a e, s 14.09 14.09 253 29.62 29.62 2.82 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0VjI 4A5-2om 4B5.21m 0550 0540 s s 1435 14.09 13A1 13.67 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0C 13A4ocs 4A5.2om 4A5-2omd 0.143 05500580 s s 6 3. 73 14. 35 15. 14 2- 90 13bl 15. 90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W VjI I-- G 12B- 09w 13A- 40CS 4AS2om 0. 097 0. 143 0550 w w w 253 3. 73 14. 35 2. 82 2. 90 27. 44 14 0 0 14 0 0 34 0 0 38 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Ili P C 4A5. 2om 12C• 09w 11DO 1613• 30ad 0550 0A91 0390 0. 032 w n 1435 238 10. 18 0. 84 27. 44 151 1227 1. 76 0_ 0 0 36 0 0 0 36 0 0 0 30 0_ 0 0 63 0 0 0 137 0 0 0 137 0 0 0 114 0 0 0 241 F _ 19C-19cscp 0.049 0.44 031 36 36 16 11 22 22 10 7 F 22A-tom 1.180 30.80 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 10 16 Emelope Iossbain 286 319 929 1288 12 a) trlfiWon 110 40 361 130 b). Room %enfilabon 0 0 0 0 13 Internal gains O=paft@ no 0 0 1 230 Applaxeslother 0 0 Subtotal ( lines 6 to 13) 397 359 1290 1648 Less erdemalload 0 0 0 0 Less trarder 0 0 0 0 Redistribution 0 0 98 539 14 Subtotal 397 359 1387 2187 15 Dud loads I 11% 24%1 44 86 11% 24% 153 523 Total room bad 440 445 1540 2710 Air required (dm) 0 21 0 130 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr` ghtsolt 2018-Mar-010853:14 A& '"""' ""'-"---- Regis-Sute4MUriversal201818.0.08RSU16202 Page L Temp\Lot 043 SorrerloA RHG Bed4 Loft- N.rup Cale a M,18 Frort Door taces' N wrightsoftRight-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Court, W irter Park FL 32792 Phore: (407) 629 - 6920 Fax: (407) 629. 9307 Web- wwwOr eSlopCoolirg com License- CAC032444 Job: Lot 043 Sorrento ARHG Bed4 ... Date: 05/20/2017 By. LF/RI/AT 1 Room name LOFT STC2 2 Exposed Hall 12.0 II 155 0 3 Room height 9.0 ff heatkool 9.0 If heattool 4 5 Room dimensions Room area 1. 0 x 191 A ff 191 A r 45 x 11 A It 495 W Ty Construction number U- value BWh4F- 9 Or HTM BWh" Area ( A) or perimeter (It) Load BWh) Area ( II) or perimeter (4) Load BWh) Heat Cod Gross NAS Heat Cod Gross NP/S Heat Cod 6 V I I--( 12B- 0sw 4A5. 20m 4B5- 2bn OA97 O- W 0540 n n n 253 14. 35 14. 09 282 13AI 1387 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 L-C Vy D 1113A- 4ors 11D0 0. 143 0390 n n 3. 73 10. 18 2. 90 1227 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ILS12B- 0sw 4AS- 2om 485. 21M 0. 097 0550 0540 a a a 2. 53 1435 14. 09 2. 82 27. 44 29. 62 0 0 0 0 0 0 0 0 0 0 0 0 99 0 12 87 0 0 220 0 169 245 0 355 13A- 4ocs 4A5- 2om 0. 143 0550 a a 3. 73 1435 2. 90 27. 44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5. 2trn 4B5. 21M 128• Osw 0540 0540 0. 097 a e_ s 14. 09 14D9 253 29. 62 29. 62 2. 82 0 0 108 0 0_ 104 0 0 263 0 0 293 0 0 41 0 0 41 0 0 103 0 0 114 4AS- 2om 4B5- 2trn 0550 0540 s s 1435 14. 09 13. 61 13. 67 0 4 0 4 0 56 0 55 0 0 0 0_ 0 0 0 0 T= 13A-4oce 4A5. 2om 4A5. 2omd 0. 143 0550 0580 s s s 3. 73 1435 15. 14 2. 90 1381 15. 90 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W y 612B- 09w 13A- 4oeS 4A5. 2orn OD97 0. 143 0550 w w w 253 3. 73 1435 2. 82 2. 90 27. 44 0 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 R L- D C 4A5- 2om _ 12C- 09w 11D0 16& 30ad 05W 0. 091 03M 0. 032 w n 1435 238 10. 18 084 27. 44 151 1227 1. 76 0_ 0 0 191 0 0 0 191 0 0 0 160 0 0 0 336 0 0 0 50 0 0 0 50 0 0 0 41 0 0 0 87 F 19C-19oscp O.049 0.44 031 3 3 1 1 0 0 0 0 F 22A-lom 1.180 3080 OAO 0 0 0 0. 0 0 0 0 6 c) AED exojrsion 21 56 Envelope loss0gain 480 663 533 857 12 a) Infiltration 177 64 228 82 b) Room verrolation 0 0 0 0 13 Internal gains Ocapants@ 230 0 0 0 0 Applianoesrolher 0 0 Subtotal pines 6 to 13) 657 727 762 940 Less external load 0 0 0 0 Lessiranster 0 0 0 0 Redist ibution 857 1475 762 940 14 Subtotal 1514 2202 0 0 15 Dud loads 1 11% 24%1 167 526 11% 24% 0 0 Total room load I I 1680 12728 0 0 Air required (dm) 0 130 1 1 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrr` glstsol!- 2018-Mar-010853,14 RigltSute® Unversal201818.0.08 RSU16202 Page L Temp\Lol 043 Sorrerto A RHG Sed4 Loft - N rup Cale a" Frort Door laces N wrightsoft Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Court Winter Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web- wawOreStopCoolirg com License CAC032444 Job: Lot 043 Sorrento A RHG Bed4 ... Date: 05/20/2017 By. LF/RI/AT 1 Room name 2 Exposedvell 0 4 45 4 3 Room height 9.0 4 heaVcool 9.0 4 heaftol 4 Room dimensions 25 x 3.0 4 45 x 45 4 5 Room area 75 W 203 W Ty Construction number U-value Btuh4R--q Or HTM BWF1 Area (W) or perimeter (4) Load BWh) Area (4x) or perimeter (4) Load Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cod 6 C 12B-OsN 4A5.20m 0.097 0S50 n n 253 1435 2.82 13AI 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 48S21m 0540 n 14.09 13.67 0 0 0 0 0 0 0 0 VpI 13A-4ocs 0.143 n 3.73 2.90 0 0 0 0 0 0 0 0 11 D 11 DO 03W n 10.18 1227 0 0 0_ 0_ 0 0 0 0 1gl I 2 1213-05w 4A5-2omQ5-21m 0.097 0550 0540 a a a 253 1435 14A9 2.82 27.44 29.62 0 0 0 0 0 0 0 0 0 0 0 0 41 0 0 41 0 0 103 0 0_ 114 0 0 G 13A-4oes 4A5.20m 0.143 0550 a a 3.73 1435 2.90 27.44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4BS21m 4B5-2tm 12B-ftN 0540 0540 0A97 a a s 14.09 14.09 253 29.62 29.62 2.82 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2om 485.21m 0550 o540 s s 1435 14.09 13.61 13.67 0 0 0 0_ 0 0 0 0 0 0_ 0 0 0 0 0 0 13A-4o s 4A5.20m 0.143 0550 s s 3.73 14.35 2.90 13.61 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5.2omd 0580 s 15.14 15.90 0 0 0 0 0 0 0 0 W yy11 EGG 128-096v 13A-40 s 4A5.20m OD97 0.143 0550 w w w 2S3 3.73 1435 2.82 2.90 27.44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Ili 4A5.20m 12C-09w 11DO _ 168-30ad 0550 0A91 0390 0.032 w" n 1435 238 10.18 0.84 27.44 151 1227 1.76 0 0 0 8 0 0 0 8 0 0 0 6 0 0 0 13 0 0 0 20 0 0 0 20 0 0 0 17 0 0 0 36 P L-D C F 19C-19cscp 0A49 0.44 031 8 8 3_ 2_ 0 0 0 0 F 22A-1Dm 1.180 30.80 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 31 Envelopelosslgain 10 15 119 119 12 a) Infi"on 0 0 66 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 4 920 Appliancesbther 0 0 Subtotal Pines 6ID 13) 10 15 186 1063 Lem external load 0 0 0 0 Lesstransler 0 0 0 0 Redistribution 10 15 186 1063 14 Sublolal 0 0 0 0 151 Dud loads 1 11% 249/6 0 0 11% 24"/0 0 0 Total room load 0 0 0 0 Air required (dm) 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrl glstsofl 2018-Mar-010853.14 Right-Sute4DUriversal 201818.0.08 RSU16202 Page 10 L Temp\Lo1043 SorrerloA RHG Bed4 Loft. N.rup Cale= KM Front Door laces N wrightsoft• Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Court Winer Park FL 32792 Phore. (407) 629 - 6920 Fax, (407) 629.9307 Web: wwwOreStopCoolirg.com License: CAC032444 Job: Lot 043 Sorrento ARHG Bed4 ... Date: 05/20/2017 By: LF/RI/AT 1 Room name BTH2 2 Exposed Nell 0 e 3 Room height 9.0 4 heaftol 4 Room dimensions 6A x 55 f1 5 Room area 33D W Ty CConstrudion U-vaalue Or HTM Area (It) Load Area Load number Bbuh4RL`9 Bbu11AP) or perimeter (II) BWh) or perimeter Heal Cod Gross NiPIS Heat cod Gross PUPS Heal Cod 6 V)I 12B-09w OD97 n 2.53 2.82 0 0 0 0 4A5.2om OS50 n 1435 13.41 0 0 0 0IE---GG 4BS21m 0540 n 14.09 13.67 0 0 0 0 VI-D 13A-40cs 0.143 n 3.73 2.90 0 0 0 0 1 1 11 DO 0390 n 10.18 1227 0 0 0 0 12B-0sw OD97 a 253 2.82 0 0 0 0 4A5.2om O-&W a 1435 27.44 0 0 0 0 485-21n 0540 a 14.09 29.62 0 0 0 0 G 13A-4ocs 0.143 a 3.73 2.90 0 0 0 0 4A5.2om 050 a 1435 2. 0 0 0 0 L G aBS2bn OS40 a 14.09 299.6262 0 0 0 0 4135.21n 0540 a 14.09 29.62 0 0 0 0 1213-09w 0.097 s 2.53 2.82 0 0 0 0 4A5-2om 0550 s 14,35 13.61 0 0 0 0 485-21m. 0540 s 14.09 13.67 0 0 0_ 0- 13A-4ocs 0.143 s 3.73 2.90 0 0 0 0 4A5.2om 0550 s 1435 13.61 0 0 0 0 4A5-2omd 0580 s 15.14 15.90 0 0 0 W 1213-0sw 0.097 w 253 2.82 0 0 0 0 0 2 13A-40cs 4A5-20m 0.143 0550 w w 3.73 1435 2.90 27.44 0 0 0 0 0 0 0 0 4A5.20m 0550 w 1435 27.44 0 0 0 0 R I--D 12C-09w 0.091 238 151 0 0 0 0 11 DO 0390 n 10.18 1227 0 0 0 0 c 1613-30ad 0.032 0.84 1.76 33 33 28 58 F 19C-19csg1 0.049 0.44 031 27 27 12 8 F 22A-bxn - 1.180 30.80 0.00 0 0-- 0 0 6 c) AED excursion 2 Envelope lossigain 40 65 12 a) Irfillrabon 0 0 b) Room ven8lalion 0 0 13 hiemal gains: Oo @ 230 0 0 ApphancestfW 0 Subtotal (lines 6 to 13) 40 65 Less eA8rrkd load 0 0 Lesstansfer 0 0 Redislribulion 3 4 14 Subtotal 42 69 15 Dud bads 1 11%, 24%1 5 16 Total room load 47 85 Air required (dm) 0 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t- wr`gtstsoTt 2018-Mar-010853.14 cA "^"' "-^ Rig116Sute6Uriversal201818A.08 RSU16202 Page 11 L TempNLot 043 SorrerloA RHG Sed4 Loll- N.rup Calc-" Fron Door laces: N Duct System SJob: LoI043 Sorrer4o ARHG B... wrightsoft• y Summary Date: 05/20/2017 Entire House By. LF/RI/AT One Stop Cooling and Heating 7225 Sardscove Co rL W uter Park FL 32792 Phore: (407) 629 - 6920 Fax. (407) 629 - 9307 Web. wwwOreStopCoolmg com Louise: CAC032444 For: Park Square Homes 3962 Saltmarsh Loop, Sanford, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0. 50 in H2O 0. 16 in H2O 0. 34 in H2O 0. 170/0.170 in H2O 0. 169 in/100ft 0 cfm 201 Cooling 0. 50 in H2O 0. 16 in H2O 0. 34 in H2O 0. 170/0.170 in H2O 0. 169 in/100ft 1160 cfm Name Design Btuh) Htg cfm) Gg cfm) Design FR Diam in) H x W in) Dud Matt Actual Ln ( ft) Ftg. Egv Ln ( ft) Trunk BED2 c 1730 0 83 0.277 6.0 Ox 0 VIFx 22.8 100.0 SO BEDS c 1776 0 85 0.268 6.0 Ox 0 MR 22.1 105.0 SO BEN c 2710 0 130 0.275 7.0 Ox 0 MR 23.7 100.0 SO BTH2 c 85 0 4 0.307 4.0 Ox 0 VIFx 15.6 95.0 st1 DWE c 1239 0 59 0.179 5.0 Ox 0 VIFx 45.4 145.0 st3 GRT c 3964 0 189 0.176 9.0 Ox 0 VIFx 48.0 145.0 st3 Kfr c 2141 0 102 0.214 6.0 Ox 0 MR 28.9 130.0 st2 LNDV c 1206 0 58 0.228 5.0 Ox 0 VIFx 24.4 125.0 st2 LOFT• A c 2728 0 130 0.282 6.0 Ox 0 VIFx 20.5 100.0 SO MBED c 3463 0 166 0.170 8.0 Ox 0 VIFx 50.5 150.0 st3 MBTH c 1301 0 62 0.169 5.0 Ox 0 VIFx 51.4 150.0 st3 wrol c 44 0 2 0.177 4.0 Ox 0 VIFx 41.9 150.0 st3 MWr, A c 228 0 11 0.176 4.0 Ox 0 VIFx 43.4 150.0 st3 PWDR c 1210 0 58 0.219 5.0 Ox 0 VIFx 24.9 130.0 st2 TOp c 445 0 21 0.293 4.0 Ox 0 MR 20.9 95.0 st1 Trunk Htg Cig Design Veloc Diam H x W Duct Name Type dm) cfm) FR fpm) in) in) Material Trunk st2 PeakAVF 0 707 0.169 662 14.0 0 x 0 unIFIX st1 PeakAVF 0 453 0.268 577 12.0 0 x 0 unIFIX s13 PeakAVF 0 489 0.169 623 12.0 0 x 0 unIFIX st2 wrightsoTt' 2018-Mar-010853:16 r.... Right-Sute®Unversal2018 18.0.08 RSU16202 Page 1 ACCk ... L Temp\Lo1043 SorrertoA RHG Bed4 Loft. N.np Calc- MA Frort Door laces N Name Grille Size (in) Htg cim) Clg cim) TEL ft) Design FR Veloc tpm) Diam in) H x W in) Stud/Joist Opening (in) Dud Mal Trunk rb1 Ox 0 0 1160 0 0 0 0 Ox 0 VIFx wrightsoft' 2018-Mar-01 0853:16 w• .....,.,•.-. , Righ-SUIe®Uriversa1201818.0.08 RSU16202 Pape 2 14CCP....L Templet 043 Sorrerlo A RHG Bed4 Loll - N nq Calc -" Frort Door laces N Static Pressure and Friction Rate Job: Lot 043Sorrento ARHGB... wrightsoft' Date: 05/20/2017 Entire House By. LF/RI/AT One Stop Cooling and Heating 7225 Sardscove Cout W irter Park FL 32792 Phone: (407) 629.6920 Fax, (407) 629 - 9307 Web wvrwOneStopCoolirg.com License: CAC032444 For: Park Square Homes 3962 Saltmarsh Loop, Sanford, FL Heating Cooling in H2O) in H2O) External static pressure 0.50 0.50 Pressurelosses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 0.34 Total• Supply Return ft) ft) Measured length of run -out 15 0 Measured length of trunk 37 0 Equivalent length of fittings 150 0 Total length 201 0 Total effective length 201 FrictionRate Heating Cooling . in/ 100ft) in/100ft) Supply Duds 0.169 OK 0.169 OK Return Duds 0.169 OK 0.169 OK Fitting Equivalent LengthDetails supply 4X--35,11 A=20,11 G=5,11 G=5,11 A=20,11 J=15,1 A--35,11 G=5,11 G=5,11 Gam: TotalEL=150 Return TotalEL=O wrightsoft' 2018-Mar-01 0853:16 Righ- Sute®Uriversal 201818,0.08 RSU16202 Page 1 A .- L TempIot 043 Sorrerto A RHG Bed4 Loft- Niup Cale - MA Frort Door taces N 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 043 Sorrento A RHG Bed4 Loft - N Builder Name: Park Square Homes Street: 3962 Saltmarsh Loop Permit Office: City of Sanford City, State, Zip: Sanford , FL , Permit Number: Owner: Park Square Homes Jurisdiction: 691500 Design Location: FL, Orlando COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fore snrinkler cover plates and walls or reolpring a. In addition, inspection of log walls shall be in accordance with the provisions of IGG-400. 3/1/2018 9:07 AM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 10X6 62 cfm 10X6 58 cfm EF1 VfW Job #- Lot 043 Sorrento A RHG Bed4 Loft - N Performed by LF/RVAT for: Park Square Homes 3962 Sahmarsh Loop Sanford, FL Level 1 EF1 = 50 CFM Fan EF2 = 80 CFM Fan EF3 = 110 CFM Fan EFL1 = 50 CFM Fan EFL2 = 80 CFM Fan EFL3 = 110 CFM Fan VTR = Vent to Roof VTW = Vent to Wall DV = Dryer Vent RV = Range Vent Lineset Chase Condensate O= Thermostat 18/8 SRB = Small Reduction Box LRB = Large Reduction Box FBB = Feld Built Box One Stop Cooling and Heating 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 wAw OneStopCooling.com Scale:1 : 95 Page 1 Right -Suite® Universal 2018 18.0.0E RSU16202 2018-Mar-010857:13 Sorrento A RHG Bed4 Loft - N.nrp Job #: Lot 043 Sorrento A RHG Bed4 Loft - N Pertormed by LF/RVAT for: Park Square Homes 3962 Saltmarsh Loop Sanford, FL Level 2 One Stop Cooling and Heating 7225 Sandscove Court Winter Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 wAw OneStopCooling.00m 4"cale:1 : 95 Page 2 Right -Suite® Uruversal 2018 1110.08 RSU 16202 2018-Mar-0108:57:13 Sorrenlo ARHG Bed4 Loft- N.rup pal- S(u 9-14a/h cr to&trjoXas Snv(=-," RECORD COPY s 7t? 9iLoory d AJ VIP 2 4 If LALP Pfll h A, 3 4 3 OJLDpyG SANFORD DESCRIPTION AS FURNISHED: Lot 43 , WYNDHAM PRESERVE, as recorded in Plat Book 81, Pages 93 through 102 of the Public Records of Seminole County, Florida. PLOT PLAN FOR/CERTIFIED TO: Park Square Enterprises, LLC (a Delaware Corporation); Winderweedle, Haines, Ward & Woodman, PA; Attorneys' Title Insurance Fund; 6a'nk of Americo P.C. RECORD COPY 0 I LOT 44 L_ N 89P40'51 " E 54.89' tip° i I 1 I I D=90002'12" R=25.00' L=39.29' / C=35.37' CB=N 45018'03" W SETBACKS AS FURNISHED FRONT - 25'(•) REAR a 20' SIDE a 5' (40' LOT) 7.5' (60' LOT) 10' (75' LOT) SIDE STREET - 25' (60' & 75' LOT) 15' (40' LOT) 25' FRONT SETBACK CAN BE REDUCED TO 20' ON CERTAIN LOTS. NO MORE THAN 2) IN SUCCESSION AT 20' AND A MINIMUM OF (2) IN SUCCESSION AT 25' PROPOSED a FINSHED SPOT GRADE ELEVATIONS PER DRAINAGE PLANS G ten- Q PROPOSED DRAINAGE FLOW LOT GRADING TYPE A E{ OQO PROPOSED F.F. PER PLANS a 28.8' QQ` LOT 43 I 18.61' 14, I I I PROPOSED RESIDENCE 2078-SORRENTO-A o 2 CAR GARAGE RIGHT I I I I 79.p4' 9.3, I 5.20, LOT 42 5.20' 3P s- y6 JI I DATE_ Ok to construct single family home with setbacks and impervious are; shown on plan. 37.9 % , BLUE GROUSE LANE 2078 Sorre it> -/- 1 C=p, 50'PRIVATE R/W) PLOT PLAN ONLY PLOT PLAN AREA CALCULATIONS NOT A SURVEY TOTAL LOT AREA 6,292 t SQUARE FEET FLATWORK ON/OFF LOT a TOTAL 3 SQUARE FEET FLATWORK DRIVE 4031 128- 532 t SQUARE FEET FOUNDATION/PAD 1,756 3 SQUARE FEET WALKS 37/ 894a 9J1t SQUARE FEET REAR PATIO 112 t SQUARE FEET FROM PORCH DECK 60 f SQUARE FEETSOD3,945 11,025- 4,970 f SQUARE FEET POOL DECK f SQUARE FEET NOTE FROM SIDEWALK AND STREET LOCATION TAKEN FROM PLANS PROVIDED BY Cu NT • NOT FIELD VERIFlED CRUSETNMETYER- SCOTT & ASSOC., INC. - LAND SURVEYORS I ULU— P RAT IA. IRS)"DPIIC IA. IRDN ROD C. H. CONCRETE H7RBO17 SET LR. IR' IA •/NLI 4578 REC. RECOVERED PAD. PIIINi OT BEGD4ONG P. 6C. POINT OF CIRDOXEMEIR E CENTCRLDC IbD HAIL L DISK R/ V RIGHT -Or -VAT MT. EASEMENT ORMrt DRAINAGE VTIL. arc. UTILITY OWNLINKFENCE VD/ C. VOOD FEMCE Cro CONCRETE POCK P. C. POINT OF CURVATURC P. T. POINT OF TANGENCY st' fV1101 R RADA AMC LENGTH 0 DELTA D LLCHOBEARING P 5400 E. COLONIAL DR. ORLANDO. FL. 32807 (407)-277-3232 FAX (407)-658-1436 POI/ IT ON LINE NOTES: TV P A. rnIEAL POINTorREVOKE CYRV TIDIC 1. THE UNOE7TSEGNED DOES HEREBY CERw THAT THIS SLRTVEY man THE STM/LV m Or PRAL:RCE SET roRDI Br THE n=44 BMRO PF CL POINT OT COMPOUND CWVATWC PROlES510NA1. SWAZMRS AND MAPPERS INR CHAP= 91-17 ORIM ADMINISTRATIVE CODE PkMUW ID SMIRCH 472027, FLORIDA STATUES RAL H.Q. RADIAL NON -RADIAL 2. UNlL55 EM8055ED WITH SURVEYORS SIGNATURE AND ORIGUW. RAISIN SEAR. THIS SURVEY MM OR COMM ARE NOT VAU0. VP. VITHESS POW: I THIS SURVEY WAS PREPARED FROM TRUE INFORMATION FURNISHED TO THE SURVEVIOR, THERE MAY BE OMER RESTRICTIONS CALL CALCULATE OR EASEWENTS TAW AFFECT THIS PROPERTY. FAX PERHAHENT nrato= 1ONUNEIT ND UNDERGROUND WPROVEUEIM HAVE DUN LMTED UNLESS OIHERIIISE SHOWN. Fr. 034. FINISHED FLOOR ELEVATION BUILDING SETBACK LINE S THIS SURVEY LS PREPARED FOR THE SOLE BENEFIT OF THOSE CERTIFIED TO AND SHOULD NOT BE RELIED UPON BI' ANY OTHER ENRTY. BA BEICHWARK 0. ONENSIONS SHOWN FOR THE LOCATION OF INPROKLEMS HEREON SHOULD NOT BE USED TO REC01S EMT BDUNOAWr UNE9. LIL DAZE DEARING 7. BF.VIINRi ME BASED ASSUMED OATUAI AND ON THE LINE M MM AS BASE BEARING (B.B.) A amIrICK V SHOW4 ARE BASED ON N4110NAL GEODETIC VERTICAL DAM or 1928. UK= OIHERINSE NOTED. 9. CERRFRAre Or AUMOMLATION HL 4."S. L) CERTIFIED BY: SCALE I- DRAWN LTTT ••• DATE ORDER No. ... . PLOT PLAN 12-08-17 5446-17 REVISED PLOT PLAN (SO. FT. CALL.) 04-05-18 THIS BWLOING\PROPERTY DOES NOT LIE WTTHIN THE ESTABLISHED 100 YEAR FLOOD PLANE AS PER 'i1RM• ZONE X. LIAP / 12117CODOO F (09-28-07) TOM RUSENM R, kl_S JAM ES SCOT: FILS 1 4801 i Filename: PARK SQUARE SORRENTO 2,078SRE(FORD COPY Lighting and Small Appliance/Laundry Circuits Floor Area SmAppNo LaundNo Line Neutral 2 2 1 Lighting Summary Standard 3,527 3,527 I ------- Optional 4,506 3,527 Ranges & Ovens Range No. No? Nameplate Line Neutral 1 1 8000 2 0 0 3 0 0 Range/Oven Summary Standard 6,400 4,480 Optional 8,000 4,480 Dryers------------------------------------------------ 8-_---3-5----- Dryer No. No? Nameplate Line Neutral 1 1 5000 gV I iNG, 3 0 SAIVFORD Dryer Summary Standard 5,000 3,500 0 AgRTN1 Optional 5,000 3,500 Heating and Cooling: Actual Number 2 Name M? Ph No Amps Volts VA HP Line Neutral 1 M 1 1 14.0 240 3,360 0 1 M 1 1 2.0 240 480 0 M 1 1 5.0 240 1,200 0 1 1 1 1 14 240 1 3,360 0 2 M 1 1 14.0 240 3,360 0 2 M 1 1 2.0 240 480 0 2 M 1 1 5.0 240 1,200 0 2 1 1 1 14 240 1 3,360 0 Heat/Cool Summary Standard 16,800 0 Optional 16,800 0 Fixed Appliances: Actual Number = 6 IJame M? Ph No Amps Volts VA HP Line Neutral DISP 1 1 120 600 600 600 DISH 1 1 120 1200 1,200 1,200 MICRO 1 1 120 1200 1,200 1,200 WH 1 1 18.5 240 4,440 0 OPT POOL 1 1 10 240 2,400 0 OPT POOL HEAT 1 1 31 240 7,440 0 Fixed Appliance Summary Standard 12,960 2,250 Optional 17,280 2,250 Other Appliances: Actual Number = 0 Name M? Ph No Amps Volts VA HP Line Neutral Other Appliance Summary Standard 0 0 Optional 0 0 25% of Max Motor: Line is Std Only; Neutral for Both Maximum Phase Amps Volts 1 14 240 Heat/Cool Phase Amps Volts 1 14 240 Fixed Appl, Phase Amps Volts 0 Other Appl. Phase Amps Volts 0 Max Motor Summary Standard Only 840 0 SUMMARY Standard Line Neutral Total Total = 45,527 13,757 Maximum Amperage = 190 57 Service Voltage = 240 Service Phase = 1 Optional Line Neutral Total Total = 36,714 13,757 Maximum Amperage = 153 57 Service Voltage = 240 Service Phase = 1 Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. RECORD cnm RE: P2078AC-T - Park Sq Hms/ Sorrento-AorC 2078 MiTek USA, Inc. Site Information: 6904 Parke EasttpB.11v d. Customer Info: PARK SQUARE HMS. Project Name: P2078AC-T Model: SORRENTbaT287 3o6G /Tray Clg. Lot/Block: 43 Subdivision: WYNDHAM PRESERVE 40' Address: 3962 SALTMARSH LOOP City: SANFORD State: FLORIDA Name Address and License # o t a I Engineer of Record, If there is one, for the building. Name: License #: Ctyitdress: e p_t4v: State: General Truss Engineering CHI d gn Loads (Individual Truss Design Drawings Show Special Loading Conditions): 4 Design Code: FBC2017ITP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 140 mph Roof Load: 40.0 psf # 1 a Floor Load: 55.0 psf This package includes 49 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 611315-31.003, section 5 of the Florida Board of Professional Engineers Rules. INo. Seal# ITruss Name Date No. I Seal# ITruss Name 11/12/18 Date 1 IT12944419 1A1 1/12/18 12 1 T12944430 1 B6 12 IT129444201A1T 11/12/18 I13 IT12944431 IC1 11/12/18 I 3 IT12944421 1A2T 11/12/18 114 IT12944432 JC21/12/181 4 IT12944422 1A3T 1/12/18 115 IT12944433 JC3 1/12/18 5 IT12944423 JA4T 1/12/18 116 IT12944434 1CJ 1/12/18 6 IT12944424 A5T 1/12/18 117 1 T12944435 1 CJ1 1/12/18 7 IT12944425 JB1 112/18 118 IT12944436 1CJ3 1/12/18 8 IT12944426 1132 1/12/18 11Q IT12944437 1CJ3T 1/12/18 9 IT12944427 1133 1/12/18 120 IT12944438 1CJ4 1/12/18 10 IT12944428 1134 1/12/18 121 1 T12944439 I CJ5 1/12/18 11 IT12944429 1135 1/12/18 122 IT12944440 1CJ5T 1/12/18 This item has been electronically signed and sealed by Magid, Michael, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Mid -Florida Lumber Acquisitions, Inc.. Truss Design Engineer's Name: Magid, Michael My license renewal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and property incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. j.a, "',.„jai -T ,a.•.e, 1rs.,..a, E/ f January 12,2018 Magid, Michael 1 of 2 RE: P2078AC-T - Park Sq Hms/ Sorrento-AorC 2078 Site Information: Customer Info: PARK SQUARE HMS. Project Name: P2078AC-T Model: SORRENTO - 2078 Aor C / Tray Clg. Lot/Block: 43 Subdivision: WYNDHAM PRESERVE 40' Address: 3962 SALTMARSH LOOP City: SANFORD State: FLORIDA No. Seal# ITruss Name Date 23 IT12944441 ID1 1/12/18 24 IT12944442 ID2 1/12/18 25 IT1294441LL113 1/12/18 26 IT12944444 JE1 1/12/18 27 IT12944445 IE2 1/12/18 I28 IT12944446 I F1 11/12/18 1 I29 IT12944447 I F2 11/12/18 1 I30 IT12944448 I F2A 11/12/18 1 I31 IT12944449 I F3 11/12/18 1 32 IT12944450 F3G 1/12/18 33 IT12944451 F4 1/12/18 134 IT12944452 I F4A 11/12/18 I 35 IT12944453 F5 11/12/18 136 IT12944454 I F6 11/12/18 1 137 IT12944455 JF7 11/12/18 1 138 IT12944456 1 FT1 11/12/18 I 39 __ IT12944457 I FT2 11/12/18 I 40 IT12944458 IFT3 11/12/18 1 I41 IT12944459 I FT4 11/12/18 1 I42 IT12944460 1 J3 11/12/18 1 43 IT12944461 IJ7 11/12/18 1 44 IT12944462 IPT I1/12/18 1 45 IT12944463 JKJ2 1 /12/18 46 IT12944464 IKJ3 1/12/18 47 IT12944465 JKJ7 1/12/18 I48 IT12944466 I KJ7T 11/12/18 I 49 IT12944467 I M1 11/12/18 1 2 of 2 Job Truss Truss Type Oty Ply Park Sci Hms/Sorrento-AorC 2078 T12944a19 P2078AC T Al COMMON 6 1 Job Reference (optional) Mid -Florida Lumber. Barlow. FL. 8.130 s Sep 15 2017 MTek Industries. Inc. Fri Jan 12 07:49:00 2018 Page 1 ID-LwgElgAb9YkKIRKdr2TZXPzS7xJ.HoMyHE 3CoXIY W bbOp2GIP4vaCw3LyeTYIABlpzw9on 1001 7-11-11 F 15.0-0 I 22-0-5 30-0.0 1-0{1 1-0-0 7.11-11 7 5 7-0.5 7-11-11 1-00' 40 = 4x4 = 6.00 12 30 = 4x6 = 30 = 1062.3 19-9-13 304.0 10.2.3 9.7-11 10-2-3 Scab = 1.53.5 4x4 = i LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.75 Vert(LL) -0.35 8-10 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.76 Vert(CT) -0.50 10-13 >721 180 BCLL 0.0 Rep Stress Ina YES WS 0.34 Horz(CT) 0.06 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight, 137 lb FT = 20% LUMBER. BRACING - TOP CHORD 20 SP No.2 TOP CHORD Structural wood sheathing direly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.t BOT CHORD Rigid ceiling direly applied or 9.1-5 oc bracing. WEBS 20 SP No.3 REACTIONS. (lb/size) 2=1260/0-8-0, 6=1260/0.8-0 Max Horz 2=164(LC 11) Max Uplift 2=328(LC 12), 6=328(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=2096/624, 3-4=1893/637, 4-5=1893/637, 5.6=2096/624 BOT CHORD 2-10=-441/1873, 8-10=205/1211. 6.8=-455/1821 WEBS 4-8=217/820, 5-8=467/270, 4-10=217/820. 3-10=467/270 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 8=45ft; L-30ft; eave=oft, Cat. II; Exp B: End., GCpi=0.18: MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0.0, Interior(1) 2-0.0 to 15-0-0. Exterior(2) 15.0-0 to 18-0.0 zone.C-C for members and forces 6 MWFRS for reactions shown; Lumber DOL-1.60 plate grip DOL-1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconeurrent with any other live bads. 4) - This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3.6.0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL - IO.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ili uplift at joints) except (jt=lb) 2=328,6=328. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies 0 WARNING - Varfry design Paternal. and READ NOTES ON THIS AND INCLUDED MTEK REFERENCE PAGE M67473 rev. 1dA1MIS BEFORE USE Design valid for use only with Mi7ekm connectors. This design is based only upon parameters sham, and is for an individual building component, not a truss "an. Before use, the building designer must very the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated Is to prevent buciding of individual truss web and/or Nord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. Forgers" guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss "am&, see ANsvrPI1 rtuallty criteria. DS849 and BCSI Building component 6904 Pate East Blvd. Safety Information available from Truss Plate Insibuie. 218 N. Lee Street, Suite 312. Alexandria, VA 22314 Tampa, FL 36810 Job Truss Truss Type Oly Ply Park Sq Hms/ Sorrento-AorC 2078 T12944420 P2078AC-T A1T SPECIAL 1 1 Job Reference (ootionall Mid-Flonda Lumber. Barlow, FL. 8.130 s Sep 15 2017 MTek Industries. Inc. Fn Jan 12 07:49 Ot 2018 Page I ID:L%VE/gAb9YkKfRKdr2TZXPzS7xJa_3g9dEhz6f9AgMeXZ VCdd34cFA4MHanywkHFzw9om 2-5-0 2 7-40 72-0 B 15-0-0 19.9.13 24-7.71 300-0 1 2-50 0. -0 4-" 4$$ 2-11-0 4-9.73 4-9-13 5-4-5 1-0-0 Scab = 1-55.9 5xe = INC Cc lV.V.Cw1 4x6 IIFORSCABCONNECTION. 4 26 3x4 8 ZZ- 7x6 i I.SX4 6.00 I2 3 3x4 25 7 8 3x4 II 2 27 1 14 9 q 15 6x6 = 101a,R 20 II II 2.4 II 404 — 13 12 1 5x4 II 3x4 = t.5x4 II WO= 40 = 2S 0 2 7-" + 12-0 6 I 15-0-0 I 22.2.12 30-0-0 25-0 0. •8 4-0-8 4-0.8 2.11.6 7-2-12 7.9.4 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 TCDL 10.0 Lumber DOL 1.25 BC 083 BCLL 0.0 Rep Stress Incr YES WB 0.57 BCDL 10.0 Code FBC2017rrP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 'Except' 1-3: 2x6 SP No.1 BOT CHORD 2x4 SP No.2 'Except' 2-14: 2x6 SP No.t, 4-13: 2x4 SP No.3 WEBS 2x4 SP No.3 OTHERS 2x6 SP No.1 LBR SCAB 1-3 2x6 SP No.1 one side REACTIONS. (lb/size) 1=1204/0-8-0, 9=1249/0-8-0 Max Horz 1=162(LC 10) Max Uplift 1-276(LC 12), 9=325(LC 12) DEFL. in (loc) I/dell Ud PLATES GRIP Verl(LL) -0.19 15-21 >999 240 MT20 244/190 Vert(CT) -0.3915.21 >908 180 Horz(CT) 0.22 9 n/a n/a Weight: 200 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-7-10 oc puffins. BOT CHORD Rigid ceiling direly applied or 8-3-10 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2--545/195, 2-3=2793/796, 3-4=1944/613, 4-5=1891/670, 5.6=1395/505, 6-8=2014/619, 8-9=22131648 BOT CHORD 2-15=608/2552, 14-15=-606/2531, 11.12-357/1565, 9-11=501/1945 WEBS 3.15=52/407, 3.14=989/319, 12-14=165/1157, 5-14=353/1191, 6-12 =560/245, 6-11=85/451, 8-11=2971165 NOTES- 1) Attached 8-6-3 scab 1 to 3, front face(s) 2x6 SP No.1 with 2 row(s) of IOd (0.131"x3") nails spaced 9" o.c.except : starling at 1-11-3 from end at joint 1, nail 2 row(s) at 2" o.c. for 2-8-6. 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-10: Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf; h=25ft; 8=4511; L=30tt; eave=dtt; Cat. II; Exp B; End., GCpi=0.18, MWFRS (directional) and C-C Extenor(2) 04-0 to 3-3-0, Interior(1) 3-3-0 to 154)-0, Exterior(2)15-0-0 to 18-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL-1.60 plate grip DOL=1.60 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent wrth any other live loads. 5) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 24).0 wide will to between the bottom chord and any other members. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSI/rPl 1 angle to grain formula. Building designer should verily capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=276,9=325. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING - Verily design parameters and READ NOTES ON TM AND INCLUDED WTEK REFERENCE PAGE WF7473 rev. 14100367015 BEFORE USE. Design valid for use only with Mirek® connectors This design Is based only upon parameters shown, and is for an individual building component, not a truss system Before use, the budding designer must vent' the applicability of design parameters and property incorporate this design into the overall buildup design Bracing Indicated is to provers budding of individual truss Web and/or chord member only. Additional temporary and permanent braong n ins always required for stability and to prevent collapse With possible personal injury and property damage. For general guidance regarding the fabrication. storage, delivery, erection and bracing of trusses and truss "am*. no ANSVrPrt Quality Criteria, DS849 and SCSI Building Component 6904 Parka East Blvd. Safety Information available from Truss Plate Insldute. 218 N. Lee Street, Sune 312. Alexandria, VA 22314. Tampa, FL 36610 b Truss Truss Type Oty PlyPark Sq Hms/ Sorrento-AorC 2078MT129421rP2078AGTA2TSPECIAL11 all Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Jan 12 07 49,02 2018 Page 1 ID:LwgEfgAb9YkKIRKdr2TZXPzS7xJ.DAdCNzFJjOnOngl 8E4kkg9DgObTplgm?dHgizw9ol 2,50 2- 7-" 12-0 B 17-0-0 232-12 30." 1 2-5-0 a Le 4-8-84 8 8 11 4-" 6-2-12 6.9-4 1-0-0 4x4 6.00 12 4x6 4 27 28 5 Sub = 1:56.0 REFER TO NOTE p1 FOR SCAB CONNECTION. 7x8 4 26 29 3x4 3 6 25 ? O 3x4 11 2 30 1 13 J 7 14 _ B ) s 2.4 II 2x4 II 4xl4 _ 20 II 12 11 10 1x4 II 1x4 11 300 = tx4 II 2 5-0 2- 7-" 72-0 8 17 0 0 232-12 30-04 2S-0 0. A . 4-B-B 11 4-0-0 6-2-12 6.94 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.84 TCDL 10.0 Lumber DOL 1.25 BC 0.82 BCLL 0.0 Rep Stress Inu YES WB 0.82 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 'Except' 1-3: 2x6 SP No.1 BOT CHORD 20 SP No.2 'Except' 2-13: 2x6 SP No.1, 12-16: 20 SP No.3 WEBS 20 SP No.3 OTHERS 2x6 SP No.1 LBR SCAB 1-3 2x6 SP No.1 one side REACTIONS. (lb/size) 1=1215/0-84), 7=1257/0.8-0 Max Nor[ 1-142(LC 10) Max Uplift 1-273(LC 12), 7-323(LC 12) 40 = DEFL. in (loc) Well Ud PLATES GRIP Vert(LL) -0.1914-21 >999 240 MT20 2441190 Vert(CT) -0.39 14-21 >9D9 180 Horz(CT) 0.22 7 n/a n/a Weight: 195 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing direly applied or 3-5-15 oc purlins. BOT CHORD Rigid ceiling direly applied or 8-1-8 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-536/200, 2-3-2826/830, 3-4-1893/623, 4-5-1609/593, 5-6-1605/553, 6-7-22161666 BOT CHORD 2-14-644/2588, 13-14=642/2569, 9.10=513/1919, 7-9=513/1919 WEBS 3-14-34/416, 3-13-1064/361, 4-13=-146/561, 6.10=-650/260, 6-9=0/284, 10-13-292/1373, 5-13-106/491 NOTES- 1) Attached 8.63 scab 1 to 3, front face(s) 2x6 SP No.1 with 2 row(s) of 10d (0.131"x3) nails spaced 9" o.c except. starting at 3-8-12 from end at joint 3, nail 2 row(s) at 2" D.C. for 2-8-6. 2) Unbalanced roof live loads have been considered for this design. 3) Wtnd: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL-4.2psf, BCDL=3.Opsf, h=25ft; B=4511; L=30ft; eave=oft; Cat. II; Exp B; End., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 04-0 to 3-3-0, Interior(1) 3-3-0 to 13-0-0, Exterior(2) 13)-0 to 20.0-0. Intenor(1) 20." to 31.0-0 zone;GC for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurent with any other live loads. 6) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify Capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1-273, 7.323. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies 0 WARNING • Verily deslgrt peramelars end READ NOTES ON TM AND INCLUDED NITEK REFERENCE PAGE WF7473 rid. 1063Qd1S BEFORE USE. Design valid for use only with MrrekS wrineclom This design is based only upon parameters shown, and is for an Individual budding component, not a truss system Before use, the buildup designer must vent' the appkobiiy of design parameters and property incorporate this design into the overall budding design. Breang indKeed is to prevent buWng of individual trots Web andlor Chord members only. Additional temporary and permanent brsong Is &Ways required for stability and to prevent Collapse with possible Personal injury and property damage. For general guidance regarding the fabrication. storage. delivery, erearon and brsong of trusses and truss systems, ate ANSW PII Quality criteria, OSS49 and BCSI Building Component 6904 Pause East Blvd. Safety Information available from Truss Plele Insldule. 21a N. Lee Street, Suite 312, AlexandM, VA 22314. Tampa, FL 36810 Job Truss Truss Type oy Py Park Sq Hms/ Sorrento-AorC 2078 T12944422 P2078AC-T A3T SPECIAL 1 1 o ' all Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries. Inc Fri Jan 12 07:49:03 2018 Page 1 I D: LwgEfgAb9YkKfRKdr'2TZXPzS7xJ-hN BbaJGxUjvtP_KAiybzH2iPZOxIYGSvE GPrM8zw9ok I g-12 11-0-0 2-0-8 19-0-0 24.2-12 30-0-0 1 2.5-0 0-0 4 2 4 4-2 1-0 8 6.11-8 5.2-12 5 9 4 1-0-0 6.00 12 5x5 = 150 II REFER TO NOTE #1 4 0 26 27 28 4xe 296 Scale - 1.52.2 2x4 11 _... _ _ 12 11 10 1x4 11 30 11 5x8 = 1x4 11 40 = 1 2252 0• A1 to 241. 1- 01 2.1122 + 2 4-1-4 -04 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Gnp DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Inv YES BCDL 10.0 Code FBC2017/rP12014 LUMBER - TOP CHORD 2x4 SP No.2 'Except- 1-3: 2x6 SP No.1 BOT CHORD 20 SP No.2 'Except- 2-13: 2x6 SP No.1, 5-12: 2x4 SP No.3 WEBS 20 SP No.3 OTHERS 2x6 SP No.1 LBR SCAB 1-3 2x6 SP No.1 one side REACTIONS. (lb/size) 1=1204/0-B-0, 8=1249/0-8-0 Max Horz 1-121(LC 10) Max Uplift 1=276(LC 12), 8-325(LC 12) CSI. DEFL. in (loc) I/den L/d TC 0.83 Vert(LL) 0.2014-20 999 240 BC 0.81 Vert(CT) 0.4014-20 894 180 WB 0.53 Horz(CT) 0.22 8 n/a n/a Matrix -MS PLATES GRIP MT20 2441190 Weight: 196 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-2-12 oc pur ins. BOT CHORD Rigid ceiling directly applied or 7-10.10 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=530/204, 2-3=2870/870, 3-4=304611018. 4-5=19191696, 5-6=19211701, 6-7 =1764/ 610, 7-8-2237/702 BOT CHORD 2- 14=683/2631, 13-14L423/1806, 5 13=419/215, 10.11=555/1946, 8-10=555/1946 WEBS 3-14- 543/267, 4-13=-165/547, 11-13=347/1380, 6-13-155/574, 6-11-12/281, 7-11=503/ 217. 4-14=-417/1255 NOTES- 1) Attached 7- 11-3 scab 1 to 3, front faces) 2x6 SP No.1 with 2 row(s) of 10d (0.131"0") nails spaced 9" o.c.except , starting at 3.1-13 from end at joint 3, nail 2 row(s) at 2" D.C. for 2-8-6. 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-10; Vu8=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL-3.0psf; h=25ft; B=45ft, L=3011, eave=4ft; Cat. II, Exp B; End., GCpi=0.18; MWFRS (directional) and C-C Extenor(2) 0-4-0 to 33-0, Intenor(1) 3-3-0 to 11-0-0, Exterior(2) 11-0-0 to 22-0.0, Interior(1) 22.0.0 to 31.0.0 zone,C-C for members and forces 8 MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0.0 wide will rd between the bottom chord and any other members. 7) Bearing at joints) 1 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verity capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (A=lb) 1=276,8= 325. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING • Vedly daslgn persmef. end READ NOTES ON THIS AND INCLUDED MINK REFERENCE PAGE WI.7473 rw, faotXWO15 BEFORE USE. Design valid for use only with MTek® connectors, This design is based only upon parameters drown, and is for an individual budding component, not a truss system Before use, the building designer must vent' the applicability of design parameters and property Incorporate this design into the overall budding design. Bracing indicated is to proven bulding of individual truss web and/or chord members only. Additional temporary and permanent bracing IRAn'r' its always required for siabddy and to prevent collapse with possible personal injury and property damage. For general guidance regarding the U6lfl'. fabrication, storage, delivery. erection and braung of trusses and truss systems, we ANSII IM Owety Criteria. DSB-99 and SCSI Building Component 6904 Parke East Blvd. Safely Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria, VA 22314 Tamps, FL 36610 b Truss Truss Type oty Ply Park Sq Hms/ Sorrerdo-AorC 2078 rP2 T72944423 078AC-T A4T SPECIAL 1 1 Mid-Flonda Lumber, Barlow. FL. 8.130 s Sep 15 2017 MI-Tek Industries. Inc. Fri Jan 12 0749:04 2018 Page 1 ID:L"ElgAb9YkKfRKdr2TZXPzS7xJ-9ZIzo1HaF 11 kl8vMF16CpFFaJpDTHh72Sw80uazw9oj 2-5-0 2- S 12 940 12-0.8 166-4 214-0 252.12 30 40 1 2 5-0 0. 8 3 2 4 32.4 3-0 8 4-512 4-512 4-2-12 4-9-4 1-0-0 REFER TO NOTE N1 FOR SCAB CONNECTION. Scab - 1:51.3 5x8 1.50 II 30 = 4x6 = 28 4 5 27 6 2829 7 6.00 12 3x4 G 3 30 1.5x4 i 6 2x4 11 d 213 ZL 4 31 1 11 9 1N1615 US = 10 ) Q 6x8 = 2x4 II 3x4 = 20 II 13 12 11 t.5x4 11 20 11 4x10 = 3x4 = 3x8 = 2S-0 2- S&12 &QO 12," 1641.4 21-0 0 30-0-0 25-0 0. -0 3.24.512 4572 940 Plate Offsets (X.Y)- 12.0.54.Edne). 14.04-0.0.7-8L 17:0.54.0.2-01. 19.0-8-0.0.0-141. I14:0.2-4.0.3-01.119:0-2-0.0-0-41 LOADING ( psf) SPACING- 2-0-0 CSI. DEFL. in loc) Uden Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Verl(LL) -0.19 14 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.98 Verl(CT) -0.39 11-25 >912 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.69 Horz(CT) 0.22 9 n/a n/a BCDL 10.0 Code FSC2017/rP12014 Matrix -MS Weight: 202 Ile FT - 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 'Except' TOP CHORD Structural wood sheathing directly applied or 3-7-7 oc purlins. 1- 4: 2x6 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.2 *Except' 2' 14. 2x6 SP No.2, 513, 2x4 SP No.3 WEBS 2x4 SP No.3 OTHERS 2x6 SP No.t LBR SCAB 1-4 2x6 SP No.1 one side REACTIONS. ( lb/size) 1-1204/0-M, 9=1249/0-8-0Max Horz 1=100(LC 10) Max Uplift 1 =276(LC 12), 9=325(LC 12) FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2--530/206, 2-3-3264/1021, 3-4=2428f796, 4-5=2418/840, 5-6-2408838, 6- 7=1941f718, 7-8=1923/651, 8-9=2225f752 BOT CHORD 2-16=-858/3068, 15-16=-858/J068, 14-15=536/2123, 11-12=432/1669, 9-11=-607/1967 WEBS 3-16=53/295, 3-15=1100/380, 4-15=171/628, 4-14=162/508, 12-14=-493/1812, 6- 14-154/611, 6-12=-678/250, 7-12=157/473, 7-11=-48/395, 8-11=349/199 NOTES- 1) Attached 10.2-10 scab 1 to 4, front face(s) 2x6 SP No.1 with 2 row(s) of 10d (0.131"xW) nails spaced 9" o.c,except : starting at 1- 11-3 from end at joint 1, nail 2 row(s) at 2" o.c. for 2-8-6. 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-10; Vuft=140mph (3-second gust) Vasd=108mph; TCDL-4.2psf; BCDL=3.Opsf; h=25tt; B=45f ; L=30ft; eave=4ft: Cat. II; Exp B; End., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0.4-0 to 3-3-0, Interior(1) 3.3-0 to 9-0.0, Exterior(2) 9-0-0 to 244)- 0, Interior(1) 24-0.0 to 31-0-0 zone;C-C for members and forces S MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL= 1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verity capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (p=1b) printed copies of this document are 1=276, 9=325. not considered signed and sealed and the signature must be verified on any electronic copies 0 WARNING - Verily design paramerars and READ NOTES ON Ties AND INCLUDED NrlEK REFERENCE PAGE WF7473 rev faCM0/5 BEFORE USE. Design valid for use only with Mnektp connectors. This design is based only upon parameters Shown, and is for an individual buildup component, not a truss system. Before use, the building designer must cony the applicability of design parameters and property incorporate this design into the overall No building design. Bracing indicated is to prevem butldrng of indrodual truss web and/or chord members only. Additional temporary and permanent bracing n is always required for Stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage. delivery, Steelton and bracing of trusses and uuss systems, see ANSVrP" Quality Crherle, DSM9 and BCSI Building Component 69W Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N Lee Street, Sude 312. Alexandre, VA 22314. Tamps, FL 36610 Job Truss Truss Type Ply Park Sq Hms/ Sorrento-AorC 2078Oty T12944424 P2078AC-T A5T SPECIAL 1 1 Job Reference (optionali Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries. Inc. Fri Jan 12 07:49:05 2018 Page 1 ID LwgEfgAb9YkK02Kdr2TZXPzS7xJ-dIJL771COL968 WpNeRMTnIXDhS061Chauy00zw9oi 2-5-0 2• 7-0-0 12-0-8 74 4-0 787-2 230-0 26 2-t2 30-0-0 t 2-5.0 4 4 4$ 5-0-6 2.38 4 32 4 4-14 .2.12 3-94 I. 5x9 30 II sxe = 1.50 II 44 = 6.0o t2 3 26 27 4 28 5 29 30 6 31 32 7 Lsmii&k I Vio"', Jr—li AIM = 1.5x4 II 14 33 t3 34 35 12 36 37 77 2x4 II 1.50 II t 5x4 II 6x6 = Sx8 = 30 = LOADING (psQ SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 'Except' 1-3: 2x6 SP No.2 BOT CHORD 20 SP No.2 'Except' 4-14: 2x4 SP No 3 WEBS 20 SP No.3 Scab - 1.52.2 3x4 = CSI. DEFL. in (toe) I/dell Ud PLATES GRIP TC 0.80 Vert(L-) 0.1116-22 >999 240 MT20 2441190 BC 0.49 Vert(CT) 0.2116-22 >809 180 WB 0,79 Horz(CT) 0.09 13 n/a n/a Matrix -MS Weight: 160 lb FT - 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc puffins. BOT CHORD Rigid ceiling directly applied or 4-4-7 oc bracing. WEBS 1 Row at midpt 3-15 REACTIONS. (lb/size) 1=396/0-8-0, 9=669/0.8-0, 13=3116/0-" Max Horz 1=80(LC 6) Max Uplift 1-126(LC 8). 9=-211(LC 8). 13-945(LC 8) Max Grav 1=404(LC 17).9=731(LC 18). 13=3116(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3L451/256, 3-4-293/1264, 4-5-310/1306, 5.6-72/301, 6-7-72/301, 7-8=-930/291, 8-9-1151/311 BOT CHORD 2-16-187/412, 15-16—1891438, 4-15=-409/215, 12-13-1708/577, 11-12=-210/813, 9-11- 217/1012 WEBS 316- 121/488, 315=-1873/578, 13-15-1840/637, 5-15-231/635, 5.13=2125/701, 7-11= 80/643, 8-11-282/114, 6-12-520/267, 5-12=606/2064, 7-12-1049/290 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind ASCE 7-10; VuR=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Ops1; h=25ft; B=45ft; L-30111; eave=oft; Cat. II, Exp B; End., GCpi=0.18, MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI t angle to grain formula. Building designer should verity capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to beanng plate capable of withstanding 100 lb uplift at joint(s) except @=lb) 1=126, 9=211, 13=945. 8) Hanger( s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 109 Ile down and 139 Ile up at 7-0. 0, 80 lb down and 91 lb up at 9-0-12, 80 lb down and 91 lb up at 11-0-12, 97 lb down and 106 lb up at 13.412, 97 lb down and 106 lb up at 15-0-0, 97 lb down and 106 lb up at 16-11-4, 97 lb down and 106 lb up at 18-11-4, and 97 lb down and 106 lb up at 2D-11- 4, and 189 lb down and 206 lb up at 23-0-0 on top chord, and 340 lb down and 158 lb up at 7-0-0, 66 lb down at 13.0-12, 66 lb down at 15.0.0, 66 lb down at 16-11-4, 66 lb down at 18-11-4, and 66 lb down at 20-11-4, and 327 lb down and 97 lb up at 22-11- 4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B) LOAD CASE( S) Standard Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING • Verily, deslpn parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERENCE PAGE WF7473 rev. 1016=015 BEFORE USE. Design valid for use only wM Mrekm connectors This design is based Only upon parameters shown, and is for an individual building component, not a truss system. Before use, the budding designer must verily the applicability of design parameters and property mcorporate thisdesign into the overall building design. Bracing indicated is to prevent budding of individual truss web and/or Nord members only. Additional temporary and permanent bracing (15Sir is ahxays requiredforstabilityandtopreventCollapsewithpossiblepersonalinjuryandpropertydamage. Fig general guidance regarding the 1, fabncelion, storage, delivery, erection and bracing of trusses and truss systems, see ANSVrPI1 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke Eau Blvd. Safety Information available Qom Truss Plate InstaNe. 218 N. Lee Street. Suite 312. Alexandria. VA 22314 Tamps, FL 36610 Job Truss Truss Type Oty Ply Park Sq Hms/Sorrento-AorC 2078 T12944424 P207SAC-TI A5T SPECIAL 1 1 It MIO-PlOncla LUMDer, I18rtOW, FL. a.1 su s sep To zui i Nit ieK inousutas. Inc. rn ,Ian 1z ut:,;v:uo zulo rage z ID LwgEfgAb9YkKiRKdr2TZXPzS7xJ4JL??ICOL9bflUYpNeRMTnIXDhSOSIChauyOOzw9oi LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plc) Vert: 1-21=-82, 3.21=-W. 3-7=-60, 7-10=-W, 1520=20, 14-23=20 Concentrated Loads (lb) Vert: 3=80(F) 7-142(F) 16=340(F) 11=327(F) 26=80(F) 27=80(F) 28=wW(F) 29=97(F) 30=97(F) 31=97(F) 32-97(F) 33=41(F) 34-41(F) 35=41(F) 36=41(F) 37=-41(F) O WARNING • Verity design parameters and READ NOTES ON THIS AND INCLUDED WTFK REFERENCE PAGE M7473 rev. 18011=015 BEFORE USE. Design valid for use only with MTeKm connectors. This design i1 based only upon parameters shown, and is for an indmdual budding component. not a truss system. Before use. the building designer must verity the applicability of design parameters and property mcorporale this design into the overall L. building design. Bracing indicated is to prevent budding of individual truss web andlor chord members only. Addmonal temporary *no permaiiem bracing Is &Ways required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the +1I1! fabrication, storage, tkbvery. erection and bracing of trusses and truss systems, tali ANSVTPII Quality Criteria, DSBa! and BCSI Building Component 6904 Parke East Blvd. InformationaSafetyInformationrabble from Truss Plate InstAute. 218 N Lee Street. Suae 312, Aleirandna, VA 22314. Tamps, FL 36610 Job Truss Truss Type Oty Park Sq Hms/ Sorrento-AorC 2078ty, T12944425 P2078AC-T S1 SPECIAL 1 1 Job Reference 'o a Mid -Florida Lumber. Banow, FL. 8.130 s Sep 15 2017 MiTek Industries. Inc. Fri Jan 12 07 49.06 2018 Page 1 ID: LwgElgAb9YkK02Kdr2TZXPzS7xJ-6x4DLlgneHSGR21N49gvgKvldwnldSLwEdVzTzw9oh 1-0-0I 6.7-4 I 12$-0 1s-4-0 120." I 274-0 1-0-0 6.7-4 8.0.12 5-0-01$0 7-0.0 1-0-0t 30 = LOADING (psf) TCLL 20.0 TCDL 10.0 BCLL 0.0 ' BCDL 10.0 LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 SPACING- 2-0.0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Ina YES Code FBC2017/TPI2014 REACTIONS. (lb/size) 2=1140/D-3-8, 7=1140/0-3-8 Max Hors 2=135(LC 10) Max Uplift 2=299(LC 12), 7=299(LC 12) 4x4 = 3x4 = 3x4 = 10 e 3x10 = 1.5x4 I I 30 = Stab a 1:49.0 CSI. DEFL. in (loc) I/deg Ud PLATES GRIP TC 0.78 Ven(LL) 0.2210-12 >999 240 MT20 244/190 SC 0.93 Vert(CT) 0.4110.12 >800 180 WB 0.57 Horz(CT) 0.06 7 n/a n/a Matnx-MS Weight 132 lb FT - 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puffins. BOT CHORD Rigid ceiling direly applied or 2-2-0 of: bracing, FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1909/608, 3-4=1661/573, 4-5=21301792, 5-6=1799/629, 6-7=1914/608 BOT CHORD 2-12=425/1673, 10-12=216/1145, 9-10=-448/1641, 7-9=445/1635 WEBS 3-12=-409/235, 4-12-141/631, 4-10=403/1080, 5-10=1085/436, 6.10=83/522 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vesd=108mph; TCDL=4.2psf: BCDL-3.Opsf: h=25ft; B=45f1; L=27tt, eave=oft; Cat. II; Exp B; End., GCpi=0.18; MWFRS (directional) and C-C Exlenor(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-8-0, Exterior(2) 12-8-0 to 15-8-0, Interior(1) 18-4-0 to 28-0-0 zone,C-C for members and forces d MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members, with BCDL = 10,Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (0-1b) 2=299, 7=299. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING - Verily design Paternal. and READ NOTES ON THIS AND INCLUDED /IITEK REFERENCE PAGE 111I167473 rev. 1000441015 BEFORE USE. Design valid for use only with Wake connectors. This design is based only upon Parameters shown, and is for an individual building component, not a truss system. Before use, the budding designer must vent' the oplikabllrty of design parameters and properly incorporate this design into the overall No building design Bracing indicated is to prevent building of individual truss web and/or chord members ony. Additional temporary and permanent bracing IN'AMT" Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the RiVIll fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPH Ouslhy Crlterfa, DS"9 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Moo Institute. 218 N. Lee Street, Suite 312. Mexandne. VA 22314 Tampa, FL 36610 Job Truss Truss Type Oty Park Sq Hms/ Sorremo-AorC 2078 T12944426 P2078AC-T B2 SPECIAL 1 ty 1Job Reference (oplionall Mid-Flonda Lumber, Bartow, FL. 8.130 s Sep 15 2017 MTek Industries. Inc. Fri Jan 12 07 49:07 2018 Page 1 ID:LwgEfgAb9YkK02Kdr2TZXPzS7xJ-a8R5OhJSYyPJubdmmgvRut411J4U4xV9uN2Vvcw9og 1-0-0I 6r7.4 I 12 ? I 20.4-0 122-0-0 T 27-0-0 1-0-0 6.7-4 6-0.12 7-8-0 1$0 5-0-0 1-0-0 40 = 1J 11 IV D 3x5 = tx4 II 3x4 = 3x8 = 30 = 1x4 II 30 = I 6-7-4 + 12A-0 I 20."- 0 122-0-0 I 27 0-0 6.7-4 6-0.12 7A1A-0 50-0 LOADING ( psf) SPACING- 2 0 0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.80 TCDL 10.0 Lumber DOL 1.25 BC 0,73 BCLL 0.0 Rep Stress Inv YES WB 0.56 BCDL 10.0 Code FSC2017/TPI2014 Matrix -MS Scale = 1,49.0 DEFL. in (loc) Well Ud PLATES GRIP Vert( LL) -0.1210.11 >999 240 MT20 2"/190 Vert( CT) -0.2910.11 >999 ISO Horz( CT) 0,08 7 n/a We Weight: 134 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 'Except' TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puriins. 4- 5: 20 SP No.1 BOT CHORD Rigid ceiling direly applied or 7.614 oc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpi 5-11 WEBS 20 SP No.3 REACTIONS. lb/size) 2-1140/0.3-8, 7=1140/0.3-8 Max Horz 2=135(LC 10) Max Uplift 2=299(LC 12), 7-299(LC 12) FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1957/588, 3-4=1398/494, 4-5=1413/470, 5-6=2153/718, 6-7=2007/634 BOT CHORD 2-13=-412/1688, 11-13=-412/1688, 10-11=607/2187, 9-10= 489/1742, 7-9=486/1739 WEBS 3-13=0/252, 3-11=-613/243, 4-11=199/767, 5-11=1067/425, 5-10=590/256, 6- 10=226/803 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd-108mph; TCDL=4.2psf, BCDL=3.Opsf; h-25ft; B=45ft, L=2711, eave=oft; Cat. It: Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-" to 2-0-0. Interior(1) 2-0-0 to 12-8-0. Exterior(2) 12-8-0 to 15- 8-0, Interior(1) 204-0 to 28-0-0 zone;C-C for members and forces d MWFRS for reactions shown; Lumber DOL-1.60 plate grip DOL= 1.60 3) Provide adequate drainage to prevent water ponding 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to beanng plate capable of withstanding 100 lb uplift at joints) except (jt=lb) 2- 299, 7=299. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING - Wfly design parameters and READ NOTES ON TM AND INCLUDED MITEK REFERENCE PAGE 601-7473 rw, 18003/7015 BEFORE USE. Design valid for use only war MRekO connectors. This desgn is based only upon parameters shown, and is for an IndMdual building component, not a truss system. Before use, the buadrng designer must verity ale appbuibaay of design parameters and propery, incorporate this design into the overall building design Bracing indicated Is to prevent budding of rndMOual miss web and/or dIord members only. Additional temporary and permanent bracing 11U1' rs always required for stabddy and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, deirvery. erection and bracing of trusses and truss systems. see ANSVIPII Owliy Cfterla, DSBa9 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate InetnNe. 216 N Lee Street, Suite 312, Alenndne. VA 22314 Tampa, FL 30610 Job TrTruss Truss Type 0y Py Park SoHms/ Sorrento-AorC 2078 T12944427 P2078AC T SPECIAL 1 1 e t Mid - Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 Mi rek Industries, Inc. Fort Jan 12 07:49:07 2018 Page 1 ID: LwgEfgAb9YkKIRKdr2TZXPzS7x,La8R50hJSYyPJubdxxngvRulBm1 J3U2LV9uN2Wtw9og 47- 0 I B 7 8 I 1-0- 8 2. 8-0 I 22-" 124-0 0 I 27-0 0 8-0-0, 1- 00 4-7-0 4-04 49" 3x4 = 3x4 = LOADING ( psf) SPACING- 2-0-0 TCLL 20. 0 Plate Grip DOL 1.25 TCDL 10. 0 Lumber DOL 1.25 BCLL 0. 0 Rep Stress Ina NO BCDL 10. 0 Code FBC2017 TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 Except' 9-13: 2x6 SP No.2 WEBS 20 SP No.3 REACTIONS. (lb/ size) 2=1166/0-3-8, 9=1521/0.38 Max Horz 2=135(LC 6) Max Uplift 2=307(LC 8), 9=-411(LC 8) 4x4 = 14 13 12 11 US = 71t6 = 3x4 = 3x8 II 4x4 = Scale - 1: 49.0 CSI. DEFL. in loc) I/dell Ud PLATES GRIP TC 0. 37 Verl(LL) -0.12 13 >999 240 MT20 240/190 BC 0. 73 Vert(CT) -0.2412-13 999 180 WB 0. 66 Horz(CT) 0.08 9 n/a n/a Matrix -MS Weight, 151 Ili FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-4-7 oc purlins. BOT CHORD Rigid ceiling direly applied or 8-10.8 oc bracing. FORCES. (lb) - Max. Comp./Max Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=2095/506, 3-4=1963/507, 4-5=1406/409, 5-6=1427/403, 6-7=2165/547, 7-8= 3013n45, 8-9=-26741659 BOT CHORD 2-15=37911832, 14-15-273/1510, 13-14=373/1890, 12-13=689/3080. 11-12=540/2425, 9-11- 528/2377 WEBS 4- 15=77/393, 4-14-456/174, 5-14=250/950, 6-14=-845/271, 7-13=1243/332, 7-12=- 679/196, 8-12=180/920, 8-11=123/491. 6-13-82/504 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind ASCE 7-10; VUM=140mph (3-second gust) Vasd=108mph; TCDL-4.2psf; BCDL=3.Opsf, h=2511; B=45R; L=27ft; eave=oft, Cat. II; Exp B; Encl.. GCpi=0.18; MWFRS (directional); Lumber DOL-1.60 plate grip DOL-1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (n=lb) 2=307. 9=411. 7) Hanger( s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 407 lb down and 133 lb up at 25.3- 4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, bads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE( S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads ( p") Vert: 1- 5=60, 5-7=-00, 7-8=60, 8-10=-60, 9-16-20 Concentrated Loads ( lb) Vert. 21 — 407(F) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING . Verily design parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE 490-7473 rev. 10r113R015 BEFORE USE. Design valid for use only with Mneklp connectors. This design 1s based only upon parameters shown, and is for an individual budding component, not a truss system. Before use. the building designer must verity the applicability of design parameters and properly incorporate Net design Into the overall buildup design Bracing indicated Is to prevent budding of individual truss web anAlor chord members only. Additional temporary and permanent bracing Iµ;A^ sW3551! I. akvaysrequiredforstabilityand10preventcollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regarding the fabncaton, storage, delivery. erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, DS849 and BCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute. 21a N. Lee Wool. Suite 312. Alexandna. VA 22314 Tampa, FL 36610 b Truss Truss Type Oy PlyPark Sq Hms/ Sorrento-AorC 2078T12944128rP2078ACTBISPECIAL11 t' all Mid-Floride Lumber, Bartow, FL. 8.130 s Sep 15 2017 MTek Industries, Inc. Fri Jan 12 07 49 08 2018 Page 1 ID:L%VEfgAb9YkKlRKdr2TZXPzS7xJ-2K Ud1K4JGXAWC7UVB8 5PL9Re4Da3eNY6c1Lzv9of rt-0-0+ 4$8 &10 8 1 10G 8 I 12 8-0 1 16410 1 II.2-12 1 27-00 8-0-0, 4- 2-016-0 2-1 3-a0 5-2-12 5-9.4 1." Snide' 1/4*-V 5x5 = 4x4 = 4. 4 = — 624 725 2 10 la 1( 11 3x4 = 3x4 — 3, 9 = 1.Sx4 II 3x4 AIM 3x4 = 8- 10-8 70 6 8 16-0-0 21-2-12 1 274).0 1 1 ) 8- 10.8 7-0.0 5•SA 5-2-12 5.9.4 Plate Offsets (X.YI— 16:0.2-8.0-2-41 LOADING ( psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/de8 Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) -0.14 15.18 >999 240 MT20 2"/190 TCDL 10.0 Lumber DOL 1.25 BC 0.81 Vert(CT) -0.29 15.18 >999 180 BCLL 0.0 ' Rep Stress Inv YES WB 0.37 Horz(CT) 0.07 9 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 146 lb FT = 20% LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-10-8 oc puffins. BOT CHORD 20 SP No.2 BOT CHORD Rigid ceiling directly applied or 7-10-10 oc bracing. WEBS 20 SP No.3 REACTIONS. ( lb/sae) 2=1140/0.3-8, 9=1140/0.3.8 Max Nor[ 2-119(LC 10) Max Uplift 2-299(LC 12), 9=299(LC 12) FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1998/696, 34=1716/603, 4-5-1495/588, 5-6=1696/688, 6-7=1289/534, 7- 8=1511/555, 8.9=2000/637 BOT CHORD 2-15-554/1760, 14-15-393/1495, 12-14-310/1294, 11-12=494/1736, 9-11=494/1736 WEBS 3-15-332/184, 4-15=1041473, 5.14=-699/292, 6-14=-245/610, 7-12=120/408, B- 12-525/218 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B-4511; L-2711; eave=4ft; Cat. 11, Exp B: End., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1.0.0 to 2-0.0, Interior(1) 2-0.0 to 8-10-8, Exterior(2) 8-10-8 to I S-8411, Intenor(1) 15-8411 to 28-0-0 zone;C-C for members and forces d MWFRS for reactions shown; Lumber DOL =1.60 plate grip DOL= 1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) - This truss has been designed for a live bad of 20.Opsf on the bottom chord in all areas where a rectangle 36-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2= 299, 9=299. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING . Vanity design pen haters and READ NOTES ON TM AND INCLUDED WTEK REFERENCE PAGE aD1.7473 rev. 149=015 BEFORE USE. Design vabd for use only with MlTeli® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss $"am Before use. the building designer must verity the applicability of design parameters and property incorporate this design into the overall DWOxig design Bracing indicated is to prevent budding of rndmdual truss web andlor tlard members only. Additional temporary and pwmanem bracing is always required for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding the - fabriration, storage, delivery, erection and bracing of trusses and truss systems, see ANSIRPIf Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Irdon allon available from Truss Plate Instdine. 218 N Lee Street. Suite 312. Alexandria, VA 22314. Tamps. FL 36610 Job Truss Truss Type Oy Ply Perk Sq Hms/ Sorrento-AorC 2078 T12944129 P2078AC-T BS HIP 1 1 Job Reference (optional) Mid -Florida Lumber, Bartow. FL 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Jan 12 07:49:09 2018 Page 1 ID-LwgEfgAb9YkKfRKdr2TZX PzS7xJ-WWYsrMLi4Zg07vnK2CIN WJyWeq_8y3boeCs9Zozw9oe 1-0-0I 4-9t1-0-0 4- 6-013" 18." + 22.2-12 I 27-" 28-0-0I 1- 0-0 4Z a2.12 40 4." 4.2.12 4-94 40 = 30 = 40 = 4 20 5 21 6 1z 1V 4x4 = US = 3x4 = 3x8 = 4x4 90- 0 18.40 27-" n. rtin n_r>_n u.nn LOADING ( psf) SPACING- 2A0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.41 TCDL 10.0 Lumber DOL 1.25 BC 0.82 BCLL 0.0 ' Rep Stress Ina YES WB 0.23 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Scab = 1:47.2 DEFL. in (loc) I/dell Ud PLATES GRIP Verl( LL) -0.14 10.18 >999 240 MT20 244/190 Vert( CT) -0.3010.18 >999 180 Horz( CT) 0.07 8 n/a n/a LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. ( lb/size) 2=1140/0.3-8, 8=1140/0.3.8 Max Horz 2=99(LC 10) Max Uplift 2=299(1_C 12), 8-299(LC 12) FORCES. ( lb) - Max Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1989/718, 3-4=1687/600, 4-5=1464/584, 5-6=1464/584, 6-7=1687/600, 7- 8=1989f?18 BOT CHORD 2-12=570/1756, 10.12=-444/1606, 8-10=578/1756 WEBS 3-12=349/228, 4-12=-126/494, 5-12=2961134, 5-10=296/134, 6-10=126/494, 7- 10=3491228 Weight: 132 lb FT = 20% Structural wood sheathing directly applied or 3-10.6 oc purlins. Rigid ceiling directly applied or 7-9-2 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind, ASCE 7-10, Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL-3.Opsf; h=25ft; B=45ft; L=27ft; eave=off; Cat. II, Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1.0-0 to 2-0-0. Interior(1) 2-0-0 to 9-0-0, Extenor(2) 9.0.0 to 22- 4-11, Interior(1) 22-4-11 to 28-0-0 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (it=lb) 2= 299, 8=299. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING • Verfy design Parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE WF7473 rev. 1003Q015 BEFORE USE. Design valid for use only with Mnek4li Connectors This design is based only upon parameters shown. and is for an individual building Component. rim a truss system. Before use, the building designer must very the applicability of design parameters and properly MCCiporole this design into the overall building design. Bracing indicated is to prevent buckling of utdrAdual truss web and/or Chord members only. Additional temporary and permanent bracing its always required for stability and to prevent Collapse with possible personal injury and property damage. For general guidance regarding the IaDriratron, siorage, delivery, erection and bracing of trusses and truss systems, ace ANSIRPII Owlhy CrherU, DSB-69 and BCSI Building Component 6904 Parke East Blvd. Solely Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria, VA 22314 Tampa, FL 36610 b Truss Truss Type Oty Ply Park Sq Hms/ Sorrento-AorC 2078T12944430 078AC TrP2 B6 HIP 1 1 0all Mid -Florida Lumber, Bartow, FL. 8A 30 s Sep 15 2017 MTek Industries, Inc. Fn Jan 12 07:49 10 2018 Pape 1 ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-J6E2iLKAotl3MWLwDW WWIEKmhTaxrsb)62Ezw9od F 1-0-01 1-1" 7.0-0 + 11-49 1 15-7-7 I 20-0-0 1 22.2"2 1 27-0-0 fB l 1-0-0 3A4 3.2-12 4_,-9 4-2-13 4-9 3.2-12 3.9 4x5 = 4xe = 30 = 1x1 II 4x8 = 4 21 522 23 24 6 25 26 7 i• w ii ii 3x4 = 64 = 300 = 3x4 1 7-0.0 1 11 4 9 I 15 7.7 F 20." 27.0-0 7-M 44 42-13 4-4-9 7-0-0 LOADING (psf) SPACING- 2 0 0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 TCDL 10.0 Lumber DOL 1.25 BC 0.80 BCLL 0.0 ' Rep Stress Incr NO WB 0.44 BCDL 10.0 Code FBC2017frP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=2022/0-3-8, 9=202310-3-8 Max Horz 2=79(LC 6) Max Uplift 2=607(LC 8). 9=-607(LC 8) Scale - 1:47.2 4x5 = DEFL. in (loc) I/den Ud PLATES GRIP Vert(LL) -0.2112-13 >999 240 MT20 244/190 Vert(CT) -0.4312-13 >746 180 Horz(CT) 0.13 9 n/a n/a Weight 140 Ile FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 5.10.10 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=3964/1173, 3-4=-3757/1129, 4-5=4188/1293, 5.6=4211/1301, 6-7=4211/1301, 7-8=3759/1129, 8-9=3966/1172 BOT CHORD 2-14=978/3504, 13-14=894/3351, 12-13=1161/4209, 11-12-894/3354, 9-11--978/3506 WEBS 3-14-265/98. 4-14-711604, 4-13-339/1134, 5-13-546/267, 6-12-5171273, 7-12-345/1147. 7-11-71 /611. 8-11-265198 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vuh=140mph (3-second gust) Vasd=108m^ TCDL=4.2psf; BCDL=3.Ops1; h=25ft; B=4511; L=27ft; eave=oft: Cat. 11; Exp B; Encl., GCpi-0.18; MWFRS (directional); Lumber DOL-1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrerd with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except (jt=lb) 2-607, 9=607. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 189 lb down and 205 lb up at 7-0-0, 97 lb down and 106 lb up at 9-0-12, 97 lb down and 106 lb up at 11.0612, 97 lb down and 106 lb up at 13-0-12. 97 lb down and 106 lb up at 13-11-4, 97 lb down and 106 Ile up at 15-11-4, and 97 lb down and 106 lb up at 17-11-4, and 189 Ile down and 205 Ile up at 20-0-0 on top chord, and 327 lb down and 97 lb up at 74)-0, 66 lb down at 9.0-12, 66 lb down at 11-0612, 66 lb down at 13-0-12. 66 lb down at 13-114, 66 lb down at 15-114, and 66 lb down at 17-114. and 327 Ile down and 97 lb up at 19-114 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead Roof Live (balanced) Lumber Increase-1.25, Plate Increase=1.25 Uniform Loads (ptf) Vert: 1-4=60, 4-7=60, 7-10a:wK 15-18-20 Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOTES ONTM AND INCLUDED aTEK REFERENCE PAGE M/F7477 rsw. /aW,7015 BEFORE USE. Design valid for use only with MrrekO connectors. This design is based ony upon parameters shown. and is for an individual buNtling component, not a truss system. Before use, the budding designer muss verify the applicability of Design parameters and property incorporate this design into the overall budding design. Bracing indicated is to prevem budding of individual truss web and/or chord member only. Additional temporary and permanent bracing IIIA.T" is always required for stability and to prenro co9apse with possible personal injury and property damage. For general guidance regarding the KIVI fabrication, storage, delivery, erection and bracing of lNsses and 1russ systems, see ANSVTP11 Quality Criteria, DSBa9 and BCSI Building Component 6904 Parke East Blvd Safety Information available from Truss Plate Inst ule, 216 N Lee Street. Suite 312, Aftundna, VA 22314. Tamps, FL 36610 Job Truss Truss Type Oty Ply Park Sq Hms/ Sorrento-AorC 2078 T1294M30 P207BAC•T B6 HIP 1 I Job Reference (onfloriall M16FIoncia Lumber, t%anow, FL. 8.130 s Sep 15 Z017 MiTek Industries. Inc. Fri Jan 12 07:49:10 Z018 Page 2 ID:LwgEfgAb9YkKiRKdr2TZXP2S7xJ-J6E2iLKnotI3MV4 wDc3VWbfEKmhTexrsbj6Ezw9od LOAD CASE(S) Standard Concentrated Loads (Ib) Vert 4-142(F) 7=142(F) 13=-41(F) 14-327(F) 11=327(F) 21-97(F) 22=97(F) 23=97(F) 24-97(F) 25=97(F) 26-97(F) 27=41(F) 28=41(F) 29=41(F) 30=41(F) 31=41(F) 0 WARMNG • Verify desln Parsmarers and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE 110167473 rev. 10011=15 BEFORE USE. Design valid for use only with MRek® connectors. This design its based only upon parameters shown, and its for an individual budding Component. net a truss system. Before use. the budding designer must verity the applicability of design parameters and property incorporate this design into the overact MR building design Bracing indicated its to prevent buckling of individual truss web andfor chord members only Additional temporary and pemtanem bracing t is always regwred for stability and to prevent collapse with possible personal injury and property damage For general guidance regarding cite fabrication, storage, delivery, erection and bracing of trusses and truss &"am*. see ANSIRPH Quality Criteria. DSB-119 and BCSI Building Component 69W Parke East Blvd Safety Information wadable from Truss Plate Institute. 218 N. Lee Street. Suite 312. Menandna, VA 22314. Tampa, FL 36810 Job Truss Truss Type Oty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944431 P2078AC-T C1 HIP 1 1 Job Reference (optional) Mid -Florida Lumber, Bartow. FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Jan 12 07:49:11 2018 Page 1 ID: L"EfgAb9YkKIRKdr2TZXPzS7xJ•SvgcG2MzcBvANDxW dkrbk 1 t9ejPOwc43WLGegzw9oc 9 1d 4-0 I 19812 I 2S2 8 t-0-0 S9 4 S2.12 3." 52.12 57-12 3 Scale = 143.3 axe = 40 = i 21 22 5 30 = 1x4 II 3x4'= 30 =US = 1x4 II 3x4 = 11-0-0 14-" I 19b-12 I 252.8 5.9.4 9 3-0M 52.12 57.12 LOADING (psf) SPACING- 2-0.0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) -0.07 11 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.51 Vert(CT) -0.14 11-12 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.39 HOIz(CT) 0.06 7 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 130lb FT is 20% LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (Ib/size) 7=1007/Mechanical, 2=1070/0-3-8 Max Horz 2=114(LC 11) Max Uplift 7=239(LC 12), 2-283(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ili) or less except when shown. TOP CHORD 2-3=1852/612, 3.4=1343/507, 4-5=1138/498, 5-6=1343/507, 6-7=1826/603 BOT CHORD 2-12 =501/1603, 11-12 =501/1603, 9-11 =292/1137, 8-9=478/1576, 7-8=478/1576 WEBS 3.11-543/240, 4-11-91/350, 59=109/346, 6-9=516/232 Structural wood sheathing directly applied or 4-1-0 oc purlins. Rigid ceiling directly applied or 8-3-10 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VuB=140mph (3-second gust) Vasd=108mph; TCDL=4.2ps1; BCDL=3.Opsf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Encl.. GCpi=0.18: MWFRS (directional) and C-C Exterior(2) -1-0.0 to 2-0.0, Interior(1) 2-0.0 to 11-0.0, Exterior(2) 11.0.0 to 14-4-0, Interior(1) 18.E-15 to 252-8 zone:C-C for members and forces d MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 24)-0 wide vAll fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except (lt=lb) 7=239.2=283. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING • Verify design parameters end READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI.7473 rev. 1"MI5 BEFORE USE. Design valid for use only with Mrr*M connectors. This design is based only upon parameters shown. and is for an individual building component, notHKatrusssyslemBeforeuse. the building designer must verily, the appbcabllity of design parameters and property Incmporale this design Imo the overall µ building design. Sang indicined is to prevent buctdeng of ndrvidual truss Web and/or Nord members only. Additional temporary and permanent bracing isis always required for stability and to prevent collapse with possible personal injury and property damage. For general gudence regarding the YaIV fatir"ron, storage, delivery, erection and bracing of trusses and truss systems, see ANSUMI Quality criteria, DS048 and BCSI Building Component 8804 Parke East Blvd. Safety Information available from Truss Palo Insidine. 218 N. Lee Street. Subs 312. Mexandna. VA 22314 Tamps, FL 36610 Job Truss Truss Type city Park Sq Hms/ Sorrento-AorC 2078Ply T729M432 P2078AC-T C2 HIP 1 1 i all Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 M7ek Industries. Inc. Fn Jan 12 07:49.12 2018 Page 1 ID:LwgEfgAb9YkKIRKdr2TZXPzS7x3-w5E TONbNU2b_MVMLG48xavd2Ov9RNEIA4pA6zw9ob 1-001 4-9-4 9.40 I 16.4-0 + 20E 12 I 25-4-0 12W-0, t-0-0 4-9.4 I 4.2-12 7-4 0 a2-12 4-SA Scale a 1.44.5 airs = 4x8 = 1 19 20 21 22 5 04 = 3x8 = 30 = 3x4 = 04 = 9.0-0 18 4-0 25." n_n_n •s n n n LOADING (per SPACING- 2-0-0 TCLL 20.0 Plate Gnp DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Inv YES BCDL 10.0 Code FBC2017/TP12014 CSI. DEFL. in loc) I/dell Ud TC 0.94 Vert(LL) 0.15 9-17 999 240 BC 0.75 Vert(CT) 0.33 9-17 913 180 WB 0.16 Holz(CT) 0.06 7 n/a n/a Matrix -MS PLATES GRIP MT20 244/190 Weight: 121 lb FT = 20e%o LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling direly applied or 8-1-3 oc bracing. WEBS 20 SP No.3 WEBS 1 Row at midpt 5-11 REACTIONS. lb/size) 2=1073/0.38, 7-1073/0-3-8 Max Hors 2=97(LC 10) Max Uplift 2=283(LC 12), 7=283(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1832/667, 3-4-1545/560, 4-5-1340/551, 5-6=15451560. 6-7-1832/667 BOT CHORD 2-11=523/1615, 9-11=347/1340, 7-9 =53111615 WEBS 3-11-321/209, 4-11--45/402, 5-9=49/402, 6.9=321/209 NOTES- 1) Unbalanced roof live bads have been considered for this design. 2) Wind: ASCE 7-10: VuR=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf; h=25ft, B=45ft; L=25f1, eave=411; Cat. If: Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0.0 to 2-0-0, Interior(1) 2-0-0 to 9-", Exterior(2) 9-0.0 to 20-8-11, Interior(1) 20-8-11 to 264-0 zone;C-C for members and forces d MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (t=lb) 2=283, 7=283. d a a Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING - Varlfy design Pa.,. and READ NOTES ON THIS AND INCLUDED M/TEK REFERENCE PAGE M P7473 rev. 18W,7015 BEFORE USE. srr Design vabd for use only wih M7ek® connectors. This design is based only upon paramefers shown, and is for an enfIrvrdual budding component, not a truss system. Before use. the buddufg designer must verily the applicability of design parameters a rl property incorporate this design ado the overall budding design. Bracing indicated is to prevent buckbng of Individual truss Web and/or chord members only. Addroonal temporary and permanent bracing 11tIn is always required for stability and to prevent collapse with possible personal injury and property damage. For general guWance regardxtg the fabrication, storage, debvery, erection and broong of trusses and truss systems, a" ANSVrPI`1 Clualny Criteria, DSB49 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Inslaule. 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tamps, FL 38610 Job Truss Truss Type Oy Ply Park Sq Hms/ Sorrento-AorC 2078 T12944433 P2078AC-T C3 HIP 1 1 Job Reference (optionall Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries. Inc. Fri Jan 12 07:49:13 2018 Page 1 ID:LwgEfgAb9YkKIRKdr2TZXPzS7xJ-OloNhkODBuAScW55H2nJh979mSISurinNXggNjZzw9oa 7-0-0 ( 10 915 1457 1 184 0 I 21512 1 25-0 126 4-01 1-0-0 3 9 Af 32.12 3 9 15 341.3 3-9-15 32-12 3-9.4 1-0-0 If 4x5 = 4x8 = 3x4 = tx4 11 Afire = 4 21 5 22 23 24 6 25 7 30 = 5x5 = 3x8 = 30 = 7.0-0 10 9.15 14$1 18 0 25.4-0 7-0-0 I'll3.8.3 3-9.15 7-0-0 Seale = 1.44.5 4x5 = LOADING (psf) SPACING- 2-0.0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Verl(LL) 0.18 12-13 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.99 Verl(CT) 0.37 12-13 832 180 BCLL 0.0 Rep Stress Incr NO WB 0.34 Horz(CT) 0.13 9 n/a file BCDL 100 Code FBC2017/rP12014 Matrix -MS Weight: 133 lb FT = 20% LUMBER - TOP CHORD 20 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 20 SP No.3 REACTIONS. (lb/size) 2=1887/0.3-8, 9=1888/0.3-0 Max Horz 2=77(LC 6) Max Uplift 2-567(LC 8), 9=567(LC 8) BRACING - TOP CHORD Structural wood sheathing directly applied or 2-7-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 5.11-0 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=3669/1086, 3-4=3456/1040, 4-5=3692/1146, 5-6=3714/1152, 6-7=3714/1152, 7-8=3459/1040, 8-9=3671/1086 BOT CHORD 2-14-900/3243, 13.14=-814/3081, 12-13-1012/3710, 11-12=-014/3084, 9.11-900/3244 WEBS 3-14=268/101, 4-14=73/598, 4-13 =273/892, 5-13=470/228, 6.12=439/237, 7-12-277/903, 7-11=-73/604, 8-11=268/100 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=4511, L=25ft, eave=4ft, Cat. II; Exp B; End., GCpi=0.18; MWFRS (directional), Lumber DOL=1.60 plate gnp DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (ft=lb) 2=567, 9=567. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 189 lb down and 204 lb up at 7-0-0, 97 lb down and 106 lb up at 940-72. 97 lb down and 106 lb up at 11.0-12, 97 lb down and 106 lb up at 12-841, 97 lb down and 106 lb up at 14-3-4, and 97 lb down and 106 lb up at 16-3-4, and 189 lb down and 204 lb up at 184-0 on top chord, and 327 lb down and 97 lb up at 7-0-0, 66 lb down at 9.0-12, 66 lb down at 11.0-12, 66 lb down at 12-M, 66 lb down at 14-3-4, and 66 lb down at 16-3-4, and 327 lb down and 97 lb up at 18-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, bads applied to the face of the truss are noted as front (F) or back (8). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plc) Vert 14=60, 4-7=-60, 7-10=60, 15 18=20 Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies QWARMNG - Vadly design paramatera and READ NOTES ON THIS AND INCLUDED M/TEK REFERENCE PAGE MP747$ rev. 180"015 BEFORE USE. Design valid for use only with Mrekm connectors. This design a based only upon parameters shown. and is for an individual building component, nor a truss syetem. Before use, the buildup designer must vent' the applicability of design parameters and properly incorporate this design into the overact is budding design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only. Additional temporary and permanent bracing 11t11e" is always required for stability and to prevent collapse wah possible personal injury and properly damage. For general guidance regarding the K#ia.!!1!M fabrication, storage, delivery, erection and bracing of trusses and truss systems, tee ANSIrP11 Quality Criteria. DS849 and SCSI Building Component 6904 Parke East Bad Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suse 312, Alexandra, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oy Park Sq Hms/ Sorrento-AorC 2078 T12844433 IP2078AC-T C3 HIP 1 IPly 1 Job Reference (optional) M16Flonde Lumber, Barlow, FL. 8.130 S Sep 15 2017 MfTek Industries. Inc. Fri Jan 12 07 49 13 2018 Page 2 ID LwgEIgAb9YkKIRKdr2TZXPzS7xJ-OloNhkOD8oAScW55H2nJh979mSISurmNXggNjZzw9oa LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 4=142(F) 7=142(F) 14=327(F) 5=97(F) 6=97(F) 12=41(F) 11=327(F) 21-97(F) 23=97(F) 25=97(F) 26=41(F) 27=41(F) 28=41(F) 29=41(F) O WARNING • Verify design paamaters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE WO.7473 rev. 180=015 BEFORE USE. Design valid for use only with MRekm conneclom This design is based Only upon parameters shown, and Is for an individual building componem, nor a wss system. Before use, the budding designer must vent' the appbcabrlrty, of design parameters and properly incorporate this design into the overall budding design. Bracing indicated is to prevent budding of individual truss web and/or chord members only. Additional temporary and permanent bracing t is always required for stability and to prevent Collapse with possible personal injury and property damage. For general guidance regarding the WI fabrication, storage, delivery. erection and bracing of trusses and wss "am&. see ANSVIM Quality Criteria, DS649 and BCS1 Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute. 218 N Lee Street. Suds 312. Alexandria. VA 22314 Tampa, FL 36610 b Truss Truss Type Oy Ply Park Sq Hms/ Sorrento-AorC 2078 rP2 T12944434 078AC-T CJ JACK 4 1 Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 M7ek Industries, Inc. Fri Jan 12 07:49.13 2018 Page 1 ID:LwgEfgAb9YkKfRKd2TZXPzS7xyOloNhkOD8oASeW55H2nJh97GgSXTuw7NXggN)Zzw9oa 1-0.0 1-0.0 Scab = 1, 10.7 0-441 . 1-0.0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.14 Vert(LL) 0.00 5 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 SC 0,03 Vert(CT) 0.00 5 >999 180 BCLL 0.0 Rep Stress Inv YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MR Weight- 6 Ile FT = 20% LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purtins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 20 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/sae) $=149/0-4-0, 3=-12/Mechanical, 4-1/Mechanical Max Hors 5=43(LC 12) Max Uplift 5=54(LC 12), 3=12(LC 1), 4=10(1-C 12) Max Grav 5-149(LC 1), 3=3(LC 8). 4=13(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10, Vuft=140mph (3-second gust) Vasd=108mph; TCDL=4.2ps1; BCDL=3.Opsf, h=25ft; B=4511, L=24ft; eave=oft; Cat. II; Ex r B; End., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces d MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live bad nonconcurrent with any other live bads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 5, 3, 4. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies 0 WARNING - Ver11y design Pa..$. and READ NOTES ON TM AND INCLUDED WTEK REFERENCE PAGE WO.7473 rev. I&W4615 BEFORE USE. Design valid for use only with Mnelab connectors. This design la based only upon parameters shown, and is for an individual budding component, not a truss system. Before use, the buldmg designer must verily the aliplxibarty, of design parameters and property incorporate this design into the overall budding design Bracing indicated is to Prevent burJduip of individual truss web and/or chord members only. Addruonal temporary and permanent bracing na @Ways required for stablay and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 1Y fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPI1 Ouallty Criteria, DSB49 and BCSI Building Component 61104 Parke East Blvd. Safety Information evallable from Truss Plate Institute. 218 N. Lee Street. Suite 312. AWAndna, VA 22314, Tamps, FL 36610 Job Truss Truss Type Oty Ply Perk Sq Hms/ Sorrento-AorC 2078 T12944435 P2078AC-T CJ1 JACK 18 1 Mid-Flonda Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries. Inc. Fri Jan 12 07 49:14 2018 Page 1 I D.LmVE"9YkKIRKdr2TZXP2S7xJ-IUMIu4Orv61JEggHrilYDMFSin_dNNXmUZwF 72w9oZ 1-0-0 1-0-0 1-0-0 1.0-0 LOADING (psf) SPACING- 2.0.0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.07 TCDL 10.0 Lumber DOL 1.25 BC 0.01 BCLL 0.0 ' Rep Stress Ina YES WB 0.00 BCDL 10.0 Code FBC2017ITPI2014 Matrix -MP LUMBER - TOP CHORD 20 SP No.2 BOT CHORD 20 SP No.2 REACTIONS. (lb/size) 3=10/Mechanical, 2=130/0-3.8, 4=0/Mechanical Max Horz 2=42(LC 12) Max Uplift 3=3(LC 9), 2-73(LC 12) Max Grav 3=11(LC 17), 2=130(LC 1), 4=12(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Scale - 1.7.0 20 = DEFL. in (loc) I/dell Ud PLATES GRIP Vert(LL) 0.00 5 >999 240 MT20 244/190 Vert(CT) 0.00 5 >999 180 Horz(CT) 0.00 2 n/a n/a Weight: 5 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0.0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing. NOTES- 1) Wind. ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf: BCDL=3.Opsf; h=25ft; B=45ft, L=24ft; eave=oft; Cat. II; Exp B; End., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces 3 MWFRS for reactions shown; Lumber DOL-1.60 plate gnp DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live bad nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 240-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING - Vwffy design p oilers end READ NOTES ON THIS AND INCLUDED NITEK REFERENCE PAGE WO.7473 rev. 10O 7015 BEFORE USE. Design valid for use only with MTelet connectors. This design is based only upon parameters shown, and is for on individual building component, not a truss system Before use, the but ding designer must vent' the apphcabitity of design parameters and property mcorporste this design into the overall No budding design Bracing indicated rs to provers buckling of individual truss web and/or Chord members only. Additional temporary and permanent bracing „'r' is always required or stabildy and to prevent collapse with Possible personal injury and property damage. For general guidance regarding the O labmatnon, storage, delivery, erection and bracing of trusses and truss "am&, see ANSVTPIt Owlhy Criteria, D5849 and BCSI Building Component 6804 Parke Fast BW Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312. Alexandria. VA 22314. Tampa, FL 36610 Job Truss Truss Type oy Ply Park Sq Hms/ Sorrento•AorC 2078 712944436 P2078AC-T CJ3 JACK 14 1 tiall Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MTek Industries. Inc. Fri Jan 12 07:49:14 2018 Page 1 ID LwgEfgAb9YkKlRKdr'tTZXPzS7x,YtUMlu4orv61JEggHAIYDMfSLmzdNNXmUZwF7zw9oZ 1-0-0 3-0-0 1-0-0 3-0-0 Scab. "I* 20 = LOADING (psf) SPACING- 2 0 0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 TCDL 10.0 Lumber DOL 1.25 BC 0.08 BCLL 0.0 Rep Stress Inv YES WB 0.00 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=71/Mechanical, 2=168/0.3-8, 4=36/Mechanical Max Horz 2.74(LC 12) Max Uplift 3=34(LC 12). 2=-66(LC 12) Max Grav, 3.71(LC 1), 2=188(LC 1), 4=52(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. DEFL. in (loc) I/dell Ud PLATES GRIP Vert(LL) -0.00 4-7 >999 240 MT20 244/190 Verl(CT) -0.01 4-7 >999 180 Horz(CT) -0.00 3 n/a n/a Weight: 11 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3.0-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph, TCDL=4.2pst: BCDL=3.Opsf; h=25ft; 8=4511; L=24ft; eave=oft; Cat. II; Exp B. Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-11-4 zone;C-C for members and forces d MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconeurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10D lb uplift at joint(s) 3, 2. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING • verify design perameres and READ NOTES ON THIS AND INCLUDED MREK REFERENCE PAGE MI.7473 rev. 104=015 BEFORE USE. Design valid for use only with MRek® connectors This design is based only upon parameters shown, and is for an indmilual buildup wmponem, notMRatrusssystem. Before use, the building designer must veiny the applicability of design parameters and property incorporate this design into the overall t building design Brecmg indicated is to provers buciding of individual truss web s Wor chord members only. Additional temporary and permanent bra" isis always required for stability and to prevent Collapse wah Possible personal injury and property l36!QdamageForgeneralguidanceregardingtheN fabrication, storage, delivery. erection and bracing of trusses and true systems, see ANSVMI Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate lnstaNe. 218 N Lee Street. Suite 312. Alexandria, VA 22314. Tampa, FL 38610 Job Truss Truss Type Oty Ply Park Sq Hms/ SOrrerdo-AorC 2078 712944437 P2078AC-T CJ3T SPECIAL 2 1 Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 Mrfek Industries, Inc Fri Jan 12 07 49 15 2018 Page 1 I D.LwgElgAb9YkKfRKdr2TZXPzS7xJ-Lgw75OPTgPOArgETPTpnmaCdjF BGMgdg_SJTnRzw9oY 1-0 0 2-5-0 7-0 3-0.0 1-0-0 2.5-0 2-0 0- 0 2x4 = 2.5.0 2A OVA LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/deg Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.11 Verl(LL) 0.01 7 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.14 Verl(CT) -0.01 7 >999 ISO BCLL 0.0 Rep Stress Ina YES WB 0.00 Horz(CT) 0.01 5 We We BCDL 10.0 Code FBC20171TPI2014 Matrix -MR Weight: 13 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3.0.0 oc puriins. BOT CHORD 20 SP No.2 'Except' BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. 3-7: 2x4 SP No.3 REACTIONS. (lb/size) 2-189/0.8-0, 5=116/Mechaniral Max Horz 2=81(LC 12) Max Uplift 2=-64(LC 12), 5=46(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10: Vuh-140mph (3second gust) Vesd=108mph, TCDL=4.2psf; BCDL=3.Opsf, h-25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; End., GCpt--O.18; MWFRS (directional) and C-C Exterior(2) -1.0.0 to 2-0-0, Interior(1) 2.0-0 to 3-0.0 zone:C-C for members and forces 8r MWFRS for reactions shown; Lumber DOL-1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-64) tall by 2-0.0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, S. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies QWARMNG . Vanity dastgn paramefersand READ NOTES ON THIS AND INCLUDED a/1TEK REFERENCE PAGE a01.7473 rev. 10N.1/2015 BEFORE USE. ft= Design valid for use Only with MRek® connectors. This design is based only upon parameters shown. and is for an individual building component, not a truss system. Before use, the building designer must verify the applKabilny, of design parameters and property mcorporafe this design into the overall building design. Bracing mdrealed is to prevent buckling of inOwidual truss web and/or chord members only. Addhronal temporary and permanent bracing 11tJ1T wIs always required for stability and to prevent collapse with possible personal vyury and prop" damage. For general guidance regarding the Mir fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII QualityCrherla, DS849 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312. Alexandria, VA 22314 Temps. FL 36610 Job Truss Truss Type Oy Py Park Sq Hms/ Sorrento-AorC 2078 T12944438IP207BAC-T CJ4 JACK 1 1 oil Mid-Flonda Lumber, Bartow, FL. 8.130 s Sep 15 2017 MTek Industries, Inc. Fri Jan 12 07.49:16 2018 Page 1 ID:LwgEfgAb9YkKlRKdr2TZXPzS7xJ•p1TVJmO5O)Y1TjgyAKOInklYfW5HtgDo21 Juzw9oX 4.7.8 4.7.8 Scab = 1.17.1 3x4 = 4.7-8 4.7-8 LOADING (psf) SPACING- 2-0.0 CSI. DEFL. in loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.30 Vert(LL) 0.03 3.6 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.25 Vert(CT) 0.05 3.6 999 180 BCLL 0.0 Rep Stress Inv YES WB 0.00 Horz(CT) 0.01 1 n/a n/a BCDL 10.0 Code F8C2017/TP12014 Matrix -MP Weight: 15 lb FT = 200% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 1=183/0.3.8, 2=123/Mechanwal, 3=59/Mec hanwal Max Horz 1=76(LC 12) Max Uplift 1=21(LC 12), 2=-65(LC 12). 3-1 (LC 12) Max Grav 1=183(LC 1). 2=123(LC 1), 3=86(LC 3) FORCES. (Ile) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 4-7-8 oc puffins. BOT CHORD Rigid ceiling direly applied or 10-0.0 oc bracing. NOTES- 1) Wrnd: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft, L=24tt, eave=4fl; Cat. II; Exp B; End., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-". Interior(1) 3.0.0 to 4-6-12 zone;C-C for members and forces d MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 3. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING . Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAOE MI.7473 rev. 101=015 BEFORE USE. Design valid for use only with MtreltO connector*. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the app4ubgdy of design parameters acid popeily Incorporate this design into the overall building design Bracing indicated is to prevent budding of mdmdual truss web and/or chord members only. Additional temporary and permanent bracing 11t1wT is allays regwred for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the i I N. fabrication, storage. delivery, erection and bracing of trusses and truss "ams, see ANSVTPH Quality Criteria, OSB49 and SCSI Building Component 6904 Parke East BM. Safety Information available from Truss plate Institute. 218 N. Lee Street. Suite 312. AlaundM. VA 22314 Tampa. FL 36810 Job Truss Truss Type Oty Ply Park Sq Hms/ Sorrento-AorC 2078 1 T12944439 P2078AC-T CJS JACK 13 Job Reference (optional) Mid-Flonda Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries. Inc. Fri Jan 12 07:49:16 2018 Page 1 ID:LwgEfgAb9YkKfRKdr'ITZXPzS7x,YptTVJm050)Y t T_pgyAKOlnkkDfVY5HIgDo21 JuzwgoX t-0-0 54-0 1.0.0 "1" 2x4 LOADING (psf) SPACING- 2-0.0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 TCDL 10.0 Lumber DOL 1.25 SC 0.26 BCLL 0.0 Rep Stress Ina YES WB 0.00 BCDL 10.0 Code FBC2017frPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=127/Mechanical, 2=264/0-3-8, 4=64/Mechanical Max Horz 2=108(LC 12) Max UPIM 3=-64(LC 12), 2=73(LC 12) Max Grav 3=127(LC 1), 2=264(LC 1), 4=91(LC 3) FORCES. (lb) - Max. Comp /Max. Ten. - All forces 250 (lb) or less except when shown. Sale a 1.17.0 DEFL. in (loc) I/defl Vd PLATES GRIP Verl(LL) 0.04 4-7 >999 240 MT20 2441190 Verl(CT) -0.06 4-7 >988 180 Horz(CT) -0.00 3 n/a n/a Weight. 18 Ili FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling direly applied or 10-0-0 oc bracing. NOTES- 1) Wind. ASCE 7-10, Vul1=140mph (3 second gust) Vasd=108mph, TCDL=4.2psf, BCDL=3.Opsf, h=25ft, B=4511; L=24ft, eave=4f : Cat. II; Exp B. End., GCpi-0.18; MWFRS (directional) and C-C Exterior(2) -1.0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads. 3) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING • Verily daslgn paramefen and READ NOTES ON THIS AND INCLUDED MTEI( REFERENCE PAGE WP?473 rev. 1600=015 BEFORE USE. Design valid for use only with Mrrek® connectors. This design is based only upon parameters shorn, and is for an individual buildup component, not a truss, system Before use, the building designer must vent' the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buoding of mdmdual truss web and/or chord members only. AddNonal temporary and permanent bracing Ilt.'AwT is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding The fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIRPN Quality Criteria, DS049 and SCSI Building Component 69D4 Parke East Blvd. Safety Information available from Truss Pate Institute. 218 N. Lee Street. Suns 312, Alexandna. VA 22314, Tamps, FL 36610 b Truss Truss Type Oy Ply Park Sq Hms/ Sorrento-AorC 2078 T12944440rP2078AC-T CJST SPECIAL 2 1 Reference1JobMid - Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 Meek Industries, Inc. Fri Jan 12 07:49:17 2018 Page 1 ID: L"EfgAb9YkKIRKdf2TZXPzS7xJ.H31 tW5RjB 1 guS80sWurFrlHIU3gsgi7zSSoasKzw9oW t- 0-0 2-7-8 5-04) t 0 0 2.7-8 2.4-8 Scab a 1.17.0 20 = 2. 7-8 2- 7-8 54- 0 24. 8 Plate Offsets (X.YI— 12.Edde.04)-41. I3:0-3-8.0.2-01 LOADING ( psf) SPACING- 2-0-0 CSI. DEFL. In loc) UdeO Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.48 Vert(LL) 0.07 6 >802 240 MT20 244/190 TCDL 100 Lumber DOL 1.25 BC 0.32 Vert(CT) -0.10 6 >597 180 BCLL 0.0 ' Rep Stress Ina YES WB 0.00 Horz(CT) 0.05 5 n/a n/a BCDL 100 Code FBC2017frP12014 Matnx-MR Weight: 19 lb FT - 20% LUMBER- BRACING - TOP CHORD 20 SP N0.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc puffins. BOT CHORD 2x4 SP No.2 'Except' BOT CHORD Rigid ceiling directly applied or 6-0.0 oc bracing. 3- 7: 2x4 SP No.3 REACTIONS. ( lb/size) 4=114/Mechanical, 2-267/0-8-0, 5=81/Mechaniwl Max Horz 2=108(LC 12) Max Uplift 4=49(LC 12), 2-72(LC 12). 5=13(LC 12) Max Grav 4-114(LC 1), 2=267(LC 1), 5=88(LC 3) FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 8=45ft; L=24A; eave=4R, Cat. II; Exp B; End., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1.0.0 to 2.0.0, Interior(1) 2-0-0 to 4-11-4 zone;C-C for members and forces d MWFRS for reactions shown; Lumber DOL=1.60 plate gnp DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads. 3) - This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ili uplift at joint(s) 4, 2, 5. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING. Vady, design parameters end READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE a0F7473 rev. 100732015 BEFORE USE. Design valid for use only with Mfrel* conneciors Thy design is based only upon parameters shown, and is for an individual bulldog component, not a was system. Before use, the budding designer must verify the sppkcabildy of design parameters and property incorporate this design Into the overall MR building design. Bracing indicated is to prevent buckling of individual truss web andror chard members only Additional temporary and permanent bracing ILtA Z isalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalinjuryandpropertydamageForgeneralguidanceregardingthef3fii fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUMI Quality Criteria, DSB49 and BCSI Building Component 6904 Parke East Blvd. Safety bdonttatlo r available from Truss Plate Instdne, 218 N. Lee Street. Suds 312, Almndna. VA 22314. Tamps, FL 36610 Job Truss Truss Type Oy Ply Park Sq Hms/ Sorrento-AorC 2078 T12944441 P2078AC-T D1 SPECIAL 1 qJ o .11 Mid-Flonda Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries. Inc. Fri Jan 12 07 49:18 2018 Page 1 I D:LwgElgAb9YkKIRKdr2TZXP2S7xJaF bGkRSMyKoliHz24bMUOCgwkT 1 HZy76g6X8Omzw9oV 5.3-0 1 911 t143 } 7603 I 181-0 42 13 I 220- 23 1-1-0I 11-/0.9 3 S3.0 8 3x4 = 8x10 = Sx5 I I 8x10 MT20HS = 40 = 20 II Scab = 1: 38.0 11 Sxt4 = 5xB MT20HS II S3-0 1 9. 11-8 1 11.10.9 + 13.11& 1 1%M 1 11-10 1 20.3-8 1 5.3- 0 4•B•8 1.11.1 2.13 2 13 2Z,3 2.2.8 LOADING (psf) SPACING- 1-4-0 CSI. TCLL 20. 0 Plate Grip DOL 1.00 TC 0.96 TCDL 10. 0 Lumber DOL 1.00 BC 0.88 BCLL 0. 0 Rep Stress Ina NO WB 0.91 BCDL 10. 0 Code FBC2017/TPI2014 Matnx-MS LUMBER - TOP CHORD 2x4 SP No.2 *Except' 510: 20 SP No. 1D BOT CHORD 2x6 SP DSS WEBS 2x4 SP No.2 *Except* 10-11, 3-17,3.5,6-15,7-14,8.13,9-12: 20 SP No.3 REACTIONS. (lb/ size) 11=5533/0.3.8, 2=2397/0-8-0 Max Horz 2=1543(LC 8) Max Uplift 11-1954(LC 5), 2-510(LC 5) Max Grav 11=6575(LC 13). 2=2612(LC 13) DEFL. in ( loc) I/defl Ud PLATES GRIP Vert(LL) 0.4215-16 >582 360 MT20 244/190 Ven(CT) - 0.721516 >337 240 MT20HS 187/143 Horz(CT) 0.07 11 n/a n/a Weight: 368 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-6-7 oc purlins, except end verlicals. BOT CHORD Rigid ceiling direly applied or 10-0-0 oc bracing. FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3-5924/1250, 3-4=-494/239, 516-780/254, 5-6=25866/8266, 6-7=258748269, 7-8- 24846/7713, 8-9-11258/3380, 9.10=-11258/3380, 10-11-5824/1738 BOT CHORD 2-17-2560/6062, 16-17-7215/22186, 15-16-7946/23843, 14-15-7713/24846, 13.14-6193/20341, 12-13-6193120341, 11- 12-235/791 WEBS 3-17-125814390, 3-5-5660/1672, 517-16475/4756, 6-15-1496/486, 7-14-2116/710, 8.13=99/390, 9.12-1474/416, 5-15-353/2257, 7.15-615/1132, 10-12-3468/11541, 8-12-10011/3101, 8-14=1675/4966 NOTES- 1) 3-ply truss to be connected together with 10d (0.131'10") nails as follows: Top chords connected as follows: 20 - 1 row at 0.7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows. 20 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (8) face in the LOAD CASE(S) section. Ply to pry connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vuh=140mph (3- second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II, Exp B; End., GCpi=0.18; MWFRS ( directional); Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live bad nonconcurrent with any other live loads. 8) ' This truss has been designed for a live bad of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except (it=1b) 11=1954,2=510. 10) Girder tames tie- in span(s): 27-" from 10-0.0 to 20-3-8 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) . The design/selection of such connection device(s) is the responsibility of others. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies LD NNRNnrovV +ompn Par .$. and READ NOTES ON THIS AND INCLUDED NITEK REFERENCE PAGE WF7473 rev. 1d4 MI5 BEFORE USE. Design valid for use only with Mrrek® conneaors This design is based only upon parameters shwm, and is for an indMifuai buildup component. notMR a truss system. Before use, the budding designermustverilytheapplicabilityofdesignparametersandpropertyincorporatethisdesignintotheovera0 g. budding design. Bracing indicated is to prevent buddingofindividualtrussWeband/or chord members only Additional temporary and permanent bracing 155f is always required for stability and to preventcollapsewithpossiblepersonalinjuryandpropertydamageForgeneralguidanceregardingtheK fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSlrM1 Quality Criteria, DS"9 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suae 312. Alexandria, VA 22314. Tamps, FL 38610 Job Truss Truss Type Oty Ply Park Sq Hmsf Sorrento-AorC 2078 T12944441 P2078AC-T D1 SPECIAL 1 3 Job Reference (ootionall Mid -Florida Lumber, Bartow, FL. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1,00, Plate Increase=1.00 Uniform Loads (pit) Vert: 1-4-40, 5-10-673, 2-11=13 Concentrated Loads pb) Vert. 5=275 0 13D s Sep 15 zun maek maustnes. Inc. rn 3an 1z u/:4v it;zuia rage z ID•LwgEfgAbgYkKlRKdr2TZXPzS7xJ4FbGkRSMyKoliHz24bMUOCgwkT/HZy76g6X80mzwgoV WARNING • Vedly design paramsrars and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE 11110-7475 rev. 10103/7015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an indmdual budding component, not a truss system. Before use, the buildup designer must vedfy, the apptrab9ny, of design parameers and property incorporate this design into the overall buildup design. Bra" indicafed is to prevent budding of individual tons web and/or chord members only. Additional temporary and permanent bracing is aways required for stability and to provers coaapsa with possible personal injury and property damage. For general guidance regarding the piqr fabrication. storage. delivery. erection and bracing of frusaea and truss systems, see ANSVIPI1 Quality Criteria, DS949 and SCSI Building Component 6904 Parke East Blvd Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suae 312. Alexandria. VA 22314 Tamps, FL 36610 Job Truss Truss Type Oty Park Sq Hms/ Sorremo-AorC 2078 JPly T12944442IP2078AC-T D2 HIP 1 1all Mid-Flonda Lumber, Bartow, FL 8.130 s Sep 15 2017 MTek Industries, Inc. Fn Jan 12 07:49:18 2018 Page 1 ID:LwgEfgAb9YkKIRKdr2TZXPzS7x,LIFbGkRSMyKoliHz24bMUOCg2UT4HZ8V 6g6X80mzw9oV 4-9.4 l l 11-0-0 15.10-12 F 3-8 4-94 4-2-12194. 4. 12 I Scab = 1: 35.1 7 a 40 = 3xS = 4x4 = 30 = 40 = 9-0- 0 i 11 8-0 20-3-8 9.0- 0 2-0.0 8.7.8 Plate Offsets ( X.Y- 15:0-5-4.0-2-01 LOADING (psf) SPACING- 2-0.0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20. 0 Plate Grip DOL 1.25 TC 0.46 Vert(LL) 0.14 10-16 >999 240 MT20 244/190 TCDL 10. 0 Lumber DOL 1.25 BC 0.69 Vert(CT) 0.31 10-16 >788 180 BCLL 0. 0 ' Rep Stress Ina YES WB 0.18 Horz(CT) 0.03 7 n/a n/a BCDL 10. 0 Code FBC2017/TP12014 Matrix -MS Weight. 100 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-7.6 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 8-10-6 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (Ib/ size) 7=810/0-3.8, 2=873/a8-0 Max Horz 2=94(LC 11) Max Uplift 7=192(LC 12), 2=237(1-C 12) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1404/529, 3-4-1092/411, 4-5=922/412, 5-0=1070/407, 6-7=1353/501 BOT CHORD 2-10=-441/1236, 8-10-220/906, 7-8=399/1162 WEBS 3- 10=365/229, 4-10=-80/308, 5-8=52/264, 6-8=305/208 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vutt=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25R, B=4511; L=24ft, eave=4f1; Cat. II; Exp B; End., GCpi=0.18, MWFRS (directional) and C-C Extenor(2) -1-0.0 to 2-0.0, Intenor(1) 2-0.0 to 9-0.0, Exterior(2) 9-0.0 to 11-8- 0, Interior(1) 16-0-11 to 20-3.8 zone;C-C for members and forces d MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1. 60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 list bottom chord live load nonconcurrent with any other live bads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except 0t=1b) 7=192, 2=237. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING - Verily dn/gn parameters and READ NOTES ON THIS AND INCLUDED aBTEK REFERENCE PAGE MF7473 rw. I&WR015 BEFORE USE. Design valid for use only with MlTelit connectors. This design is based only upon parameters shown, and is for an individual buildup component, not a truss system. Before use, the budding designer must vent' the applicability of design parameters and property incorporate this design into the overeU EF budding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 11th9nT" is always requved for stability and to prevent collapse with possible personal injury and propertydamage For general guidance regarding viRi le ll fabrication, storage, delivery, erection and bracing of trusses and truss systems, ace ANSVTPII Quality Criteria, DS849 and BCSI Bustling Component 61104 Parke Fast Blvd Safety Information available from Truss Plate Inslkuie. 218 N Lee Street. Suite 312. Alexandria. VA 22314 Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sq Hms/ Sorrento-AorC 2078 I T12944443 P207SAC-T D3 HIP 1 Job Reference (ootionall MIG-Flonda Lumber. Bartow. FL. 0.13U s bep 15 ZU11 Mt I eK InOUSUtes, Inc. Fn Jan 1Z U1 4B.1B ZU14% rage 1 ID:LwgEfgAb9YkKIRKdr2TZXPzS7xJ-DS9exnSJewdCRYFeJujwOM7bsPZIZIGvmHhwCzw9oU t-0 0 394 7.0.0 10 e-0 1341.0 16 t :12 2133-B 1-0-0 3-9-4 3-2-12 3-4-0 3-4-0 3-2.12 3.4-12 4x4 = 30 = 04 = Scab - 1.35.6 4x4 4x4 = 3x6 = 3,9 = 4X5 = 74-0 13-8-0 20.3-8 74)60 6410 &7-8 LOADING (psi) SPACING- 2-00 CSI. DEFL. TCLL 20.0 Plate Gnp DOL 1.25 TC 0.89 Vert(LL) TCDL 10.0 Lumber DOL 1.25 BC 0.75 Vert(CT) BCLL 0.0 Rep Stress Incr NO WB 0.32 Horz(CT) BCDL 10.0 Code FBC20177rP12014 Matrix -MS in (loc) Udell Ud 0.12 9-11 >999 240 0.28 9-11 >863 180 0.07 8 n/a n/a LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.1 BOT CHORD WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 REACTIONS. (lb/sae) 8=1499/0-3-8, 2=1537/0.8-0 Max Horz 2-75(LC 7) Max Uplift 8=431(LC 8). 2=467(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=2924/867, 3-4=2718/815, 4-5=2422f758, 5-6=2362/743, 6-7=26301795, 7-8=2750/821 BOT CHORD 2-11-73812576, 9-11-745/2591. 6-9=-686/2373 WEBS 3-11=267/111, 4-11=170/833, 5-11=301/162, 5-9=387/188, 6-9=1547771 PLATES GRIP MT20 244/190 Weight: 100 lb FT = 20% Structural wood sheathing directly applied or 2-6-7 oc purlins. Rigid ceiling directly applied or 7-3-6 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VuB=140mph (3second gust) Vesd=108mph; TCDL=4.2psF BCDL-3.Opsf; h-2511; 8=45ft; L=24R; eave=4R; Cat. II; Exp B; End., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate gnp DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except (jt=lb) 8=431, 2=467. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 169 lb down and 204 lb up at 7.0.0. 97 lb down and 106 lb up at 9.0-12, 97 lb down and 106 lb up at 10.44), and 97 lb down and 106 lb up at 11-7-4, and 189 lb down and 204 lb up at 13.8-0 on top chord, and 327 lb down and 97 lb up at 74).0, 66 lb down at 9.0-12, 66 lb down at 10-4-0, and 66 lb down at 11-7-4, and 327 lb down and 97 lb up at 13-7-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, bads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced). Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (phi) Vert. 1-4=60, 4-0=-00, 6-8=60, 12-15=20 Concentrated Loads (lb) Vert: 4-142(F) 6=142(F) 11=327(F) 5=97(F) 9=327(F) 19=97(F) 20=97(F) 21=-41(F) 22-41(F) 23=41(F) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING - Varffy design parameters and READ NOTES ON THIS AND INCLUDED NITEK REFERENCE PAGE MI.7473 rev. 100=015 BEFORE USE. Design valid for use only with MTek® conlllpors. This design is based only upon parameters shown. and is for an individual building componem, not a truss system Before use, the budding designer must very the applicability of design parameters and property incorporate this design into the overall budding design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only. Additional temporary and permanent bracing 11t11..T' is always required for stability and to prevent collapse wah possible personal 'vij iry and property damage. For general guidance regarding the fabrication. storage, delivery, erection and bracing of trusses and truss systems, we ANSV" Quality Criteria, DSB-e9 and BCSI Building Component 69W Parke East BNd Safety Information &wit" from Truss plate Instdute. 218 N. Lee Street, Susie 312. Alexandria. VA 22314. Tampa. FL 36610 b Truss Truss Type Oy PlyPark Sq Hms/ Sonento•AorC 2078T72944444rP2078AGTEtCOMMON11 all Mid -Florida Lumber, Banow, FL. 8.130 s Sep 15 2017 MITek Industries, Inc Fri Jan 12 07:49:20 2018 Page 1 ID:LwgElgAb9YkK02Kdr2TZXPzS7xJ-heiO97TcUy2Tyb7R BOPyTdvOUGU 13mP8POE Sfzw9oT 1-0 0 5-0-0 10-0.0 1-0-0 5-0.0 5-0-0 Scab = 1.24.0 04 = 3x4 11 4xB = 6 3x4 11 5-0-0 k 10." 4A-0 &0-0 LOADING (psf) SPACING- 2-0.0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 TCDL 10.0 Lumber DOL 1.25 BC 0.21 BCLL 0.0 ' Rep Stress Ina YES WS 0.07 BCDL 10.0 Code FBC2017/rP12014 Matrix -MS DEFL. in (loc) I/dell Ud PLATES GRIP Vert(LL) -0.01 7-8 >999 240 MT20 244/190 Vert(CT) -0.03 7-8 >999 180 HOR(CT) 0.00 6 n/a n/a LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD BOT CHORD 20 SP No.2 WEBS 2x4 SP No.3 BOT CHORD REACTIONS. (lb/size) 8=457/04-0, 6=457/0-8-0 Max Horz 8=57(LC 11) Max Uplift 8-157(LC 12), 6=157(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=420/248, 3-4=-420/248, 4-6--413/330, 2-8=413/330 Weight: 55 lb FT - 20% Structural wood sheathing directly applied or 6-0.0 oc purtins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing, NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind ASCE 7-10, Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2ps1; BCDL=3.Opsf; h-15fl; 8=45ft; L=24H; eave=4f1; Cat. 11; Exp B: Part. Encl., GCpi=0.55; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-", Intenor(1) 2-0-0 to 5-0-0, Exterior(2) 5-0-0 to 8-" zone; cantilever left exposed ;C-C for members and forces 3 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psl bottom chord live load nonconcurrent with any other live bads. 4) • This truss has been designed for a live load of 20 Opsl on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will f4 between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (t-lb) 8=157.6=157. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies 0 WARNING- Verry das/gn panmaters end READ NOTES ON THIS AND INCLUDED NITEK REFERENCE PAGE W1.7473 roV. faC.112015 BEFORE USE. Design valid for use or y with MRekm wnnapors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must vent' the applicability of design parameters and property incorporate this design into the overall MR bubding design Bracing indicated is to prevent buUding of individual truss web and/or chard members only. Additional temporary and pem anent bracing IVA wT is always required for slabildy and 10 prevent Collapse with possible personal injury and property damage. For general guidance regarding the 5 111 fabrication, storage, delivery. erection and bracing of trusses and truss systems, see ANSIrrPlt Quality Criteria, DSO-e! and BCSI Building Component 6904 Parke East Blvd. Safety Information avadable from Truss Plate Institute, 218 N Lee Street, Susie 312. Alexandria, VA 22314. Tamps, FL 36610 Job Truss Truss Type Oty Ply Park Sq Hms/ Sorrento-AorC 2078 I T12944445 P2078AC•T E2 HIP 1 Job Reference (optionall M10-FI0008 Lumber, 58nOW, FL. 8.13u s Sep tO Zut 7 Mt f eK inousufes, inC. Fn Jan R u/:4v:Zt zute rage t ID:LwgElgAb9YkKIRKdr2TZXPzS7xJ.9gHOMTUEFFAJZlidkwB?rSd4gE 1 mViZN3mo?5zw9oS 1-0-0 34-0 7-0-0 to." tt.0.0 1-0-0 3.0.0 4-0.0 3-0-0 4xe = 4x4 = 3x4 11 3KS = 3xe = 7 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. to 3-0-0 7-" 10.0.0 2A-0 44-0 3," LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.25 TCDL 10.0 Lumber DOL 1.25 BC 0.18 BCLL 0.0 Rep Stress Ina NO WB 0.15 BCDL 10.0 Code FBC2017/TP12014 Matrix -MS 1.Sx4 II DEFL. in (loc) Well Ud PLATES GRIP Vert(LL) 0.01 8-9 >999 240 MT20 244/190 Ven(CT) -0.02 8-9 >999 180 Horz(CT) 0.00 7 n/a n/a LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD BOT CHORD 20 SP No.2 WEBS 20 SP No.3 BOT CHORD REACTIONS. (lb/size) 10=497/04-0, 7=497/0-8-0 Max Horz 10=39(LC 6) Max Uplift 10=250(LC 8), 7-250(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=501/278, 3-4=-411/267, 4-5-501/277, 5.7=-469/256, 2-10=469/257 BOT CHORD 8-9=209/411 WEBS 5-8=-212/406, 2-9 =213/406 Scab = 1:22 6 Weight: 56 lb FT = 20% Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL-3.Opsf,, h=15ft, B-45ft; L=24ft; eave=oft; CaL 11; Exp B; Part. Encl., GCpi=0.55; MWFRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL-1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-" tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ili uplift at joint(s) except Qt=lb) 10=250, 7=250. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 65 lb down and 182 lb up at 3-", and 9 lb down and 76 lb up at 5.0-0, and 65 lb down and 182 lb up at 7-0-0 on top chord, and 26 lb down and 30 Ili up at 3-0-0, and 12 lb down and 13 lb up at 5-0.0, and 26 lb down and 30 lb up at 6-11.4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 6) In the LOAD CASE(S) section, loads applied to the lace of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert. 1-2=60, 2-3=-00, 3-4=-W, 4-5 =60, 54=-60, 7-10=-20 Concentrated Loads (lb) Vert 3 =18(F) 4=18(F) 9=14(F) 8 =14(F) 12=9(F) 14=8(F) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING • Verity dasign paamefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MX7473 rev. 1&=2015 BEFORE USE. Design valid for use only with M17CIO conneclon. This design Is based only upon parameters sham, and is for an individual budding component, not a truss System. Before use, the building designer must very the applicability of design parameters and property incorporate this design aro the overall budding design. Bracing indicated is to prevent bun9drng of individual Iruss web and/or chord members only. Additional temporary and permanent bracing T' Is always required for stabdM.AV rlyandtopreventcollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regarding the US fabrication, storage, delivery, erection and bracing of woes and truss systems, am ANSVrPl1 Quality Criteria, DS849 and BCSI Building Component 6904 Parke East Blvd. Safety Information available hart Truss PISIe InatdNe. 218 N. Lee Street. Suae 312, Alexandria, VA 22314. Tamps, FL 36610 Job Truss Truss Type Oy Ply Park Sq Hms/ Sorrento-AorC 2078 T12944446 P2078AC-T F1 ROOF TRUSS 4 1 e Nao-rionoa Lumoer, nartOw, rL. 0-1-8 H F 1-3-00 5x6 1 tr3 = tx3 = 1 5 4 4x6 = 2 Pky 30 = US FP = 3x3 = 1x3 11 3x3 = 3 4 5 6 7 d.1.xl s aep a zu1 f Mi t ex mdustnes, mc. rn ,Ian a of 4trzz zule rage 1 ID:LwgEfgAb9YkK1RKdr2TZXPzS7xJ-eOnnZpVsOZIABvHgJRROY2 b44RMhibIYLXXzw9oR Scab = 1.33.8 3x3 = 30 = 4x6 = 5x6 = 8 9 10 11 q7 20 II Sxe = 4x6 = 30 = 34 = lx3 II 34 = 3x4 = 4x6 = 3x8 FP = 3x3 11 5x6 = 20.2.12 20.2-12 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) Udell Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 1.00 Veri(LL) 0.39 18 613 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.71 Verl(CT) 0.54 18 447 240 BCLL 0.0 Rep Stress Incr NO WB 1.00 HOR(CT) 0.09 12 n/a n/a BCDL 5.0 Code FBC2017rrPI2014 Matrix-S LUMBER- BRACING - TOP CHORD 2x4 SP No.2D(flat) TOP CHORD BOT CHORD 2x4 SP DSS(flet) 'Except' BOT CHORD 12-14: 2x4 SP No.2(tlat) WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 23=1566/0-8-0, 12=1210/0-3-8 FORCES. (lb) - Max,Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-23=1532/0, 11-12-1203/0, 1-2-1550/0, 2-3=3838/0, 3-5=512210, 5-6-5496/0, 6-7=5496/0, 7-8=5262/0, 8-9=4501/0, 9-10=3173/0, 10-11=-1248/0 BOT CHORD 21-22-0/2841, 20-21=0/4607, 19-20=0/5425, 18-19=0/5496, 17-18=0/5496, 16-17=0/5017, 15.16=0/3959, 13.15=0/2362 WEBS 11-13--0/1662, 1-22=0/2107,10-13=1549/0, 2-22-1796/0, 10-15=0/1129, 2-21=0/1386, 9-15=1093/0, 3-21 =1070/0, 9-16=0/754, 3-20=0/717, 8-16=718/0, 5.20=-479/0, 8-17-271521, 5-19=313/500, 7-17=602/156 Weight: 106 lb FT = 20%F, 11 %E Structural wood sheathing directly applied, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3) nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. 4) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase-1.00 Uniform Loads (plf) Vert: 23-26=85(F=75), 12-26=10, 1-11=100 Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING . Verify dss/gn parameters and READ NOTES ON THIS AND INCLUDED OTE1r REFERENCE PAOE WA7473 rev. 100=015 BEFORE USE. Design valid for use only with Urek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system Before use, the buildup designer must vent' the applicability of design parameters and properly incorporate this design mill the overall bunging design Bmang agitated is to prevent bucldmng of individual truss web and/or chord members only Additional temporary and permanent bracing is always required for stabnlry and to prevent collapse With possible personal injury and property damage For general guidance regarding the aVrii!!!l11. fabrication, storage, delivery, erection and bracing of musses and tons systems. see ANSIRPIt Oualhy Criteria, DS049 and SCSI Building Component 6504 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N Lee Street. Suite 312. Alexandria. VA 22314. Tamps. FL 36610 b Truss Truss Type Oty Ply Park Sq Hms/Sorrento-AorC 2078 rP2 T12944447 078AC-T F2 ROOFTRUSS 10 1 neto-rtonba Lumber, Barlow, I-L. 3x3 14 2 B.1 Ju s Sep 1b zu1 / mi f ex inaustftes. Ine. Fn Jan 1z uv4v:zz zultf rage 1 ID:gR7GTgtGeHxJkx7yRAMor5yENIx-eOnnZpVsOZIABvHgJRROY2 hE40OVsriblVLXXzw9oR r 1.5-6 i O-W Scale - 1:26.5 4x4 = 3x3 = 1x3 11 3x3 = 3x3 = 3x3 = 110 = 3 4 5 6 7 a 17 16 15 14 13 12 11 10 0 3x3 II 4x5 = 3x3 = 34 = 1x3 II 3x3 = 3x3 = 40 = 34 = 2-9-0 5.3-0 10." 13-2.8 15.11.8 LOADING (psf) SPACING- 240-0 CSI. DEFL. in (loc) Well Ud TCLL 40.0 Plate Grip DOL 1.00 TC 0.61 Vert(LL) 0.17 12-13 999 360 TCDL 10.0 Lumber DOL 1.00 BC 0.81 Vert(CT) 0.23 12-13 816 240 BCLL 0.0 Rep Stress Inv YES WB 0.55 Horz(CT) 0.04 9 n/a n/a BCDL 5.0 Code FBC2017/rP12014 Matrix-S LUMBER- BRACING - PLATES GRIP MT20 244/190 Weight: 84 lb FT = 20%F, 11%E TOP CHORD 20 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, BOT CHORD 2x4 SP No.l (flat) except end verl call. WEBS 20 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, REACTIONS. (lb/size) 17-864/Mechanical, 9=858/0-3-8 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-17=860/0, 8-9=-853/0, 1-2=-060/0, 2-3=2054/0, 3-4=2774/0, 4-5=2774/0, 5-6=2671/0, 6.7=2069/0, 7-8=856/0 BOT CHORD 15-16=0/1614, 14-15=0/2489, 13-14=0/2774, 12-13=0/2774, 11-12=0/2509, 10-11=011607 WEBS 8-10=0/1104. 1-16=0/1145, 7-10=1044/0, 2-16 =1049/0, 7-11=0/642, 2-15=0/612, 6-11-612/0, 3-15=-605/0, 6-12-0/333, 3-14=0/581, 5-12=368/108 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-" oc and fastened to each truss with 3-10d (0.131' X W) nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING • Vanity dasrgn paramerera and READ NOTES ON THIS AND INCLUDED af/TEK REFERENCE PAGE WO.7473 rev. 1MMI S BEFORE USE. Design valid for use only with MiTeltm connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use. the building designer must verily the applicability of design parameters and property incorporate this design into the overall No building design. Bracing indicated is to prevem buciduip of rndMdual truss Web and/or chord members only. Addaional temporary and permanent bracing .wT ' is always required for stability and to prevent collapse With possible personal injury and property damage For general guidance regarding the Ihl tabrtrat on, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria. DS649 and BCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Instaute, 218 N. Lee Street. Suss 312, Akxandna. VA 22314. Tamps, FL 30610 Job Truss Truss Type Park Sq Hms/ Sorrento-AorC 2078Otyly T12844448 P2078AC-T F2A GABLE 1 1 ReferenceJob mw-rw wtl wnwCr, otlnvw, IL. r1!FE 0" JV s pep rig LV I r MI. CK rnoustne3, InG. rn Jan 1[ VrlVa:LJ LVta rage 1 ID gR7GTgtGeHxJkx7yRAMor5yENlx-6DO9n9WntO1p3sOtM5GX_HUx4ER8rgNFv3_zw9oO olle Scale = 126.5 3 4 5 6 7 8 9 10 11 12 27 qT 26 25 24 23 22 21 20 19 18 17 16 15 14 34 II 3x3 = 7.4.4 a." 1.4.0 1.4.0 1.&0 1-A.0 1-3.8 GSa • 0-7-a e.8.4 0.1.4 1-2-a 1." 1.4.0 1-4.0 1.4.0 1.4.0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/dell Ud PLATES GRIP TCLL 40.0 Plate Gnp DOL 1.00 TC 0.08 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Inv YES WB 0.03 Horz(CT) 0.00 14 n/a n/a BCDL 5.0 Code FBC2017/rP12014 Matrix-R Weight: 71 lb FT is 209/6F, I I%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, BOT CHORD 20 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(8at) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 20 SP No.3(flat) REACTIONS. All bearings 15 11-8. lb) - Max Grav All reactions 250 lb or less at joints) 26, 14, 20, 15, 16. 17, 18, 19, 25, 24, 23, 22, 21 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES. 1) All plates are 1x3 MT20 unless otherwise Indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 14-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-00 oc and fastened to each truss with 3-1Od (0.131' X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARMNG - Verily design parameters and READ NOTES ON THIS AND INCLUDED MTEK REFERENCE PAGE WP747S rev. 10003/1015 BEFORE USE. Design valid for use only with Mnek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system Before use• the building designer must verity the applicability of design parameters and property rncoipon"a this design Into the overact is building design. Bracing indicated is to prevent budding of individual truss web and/or chord members, only Additional temporary and permanent bracing IltJIwT" is akvays required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the i5 111 fabrication, storage, delivery, erection and bracing of cusses and truss systems. a" ANSVrP11 Quality Criteria, DSBa9 and BCSI Building Component 6904 Parke Fag Blvd Safety Irdontratlon available boas, Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa. FL 36610 Job Truss Truss Type Oy Py Park Sq Hms/ Sorrento-AorC 2078 T12944449 P2078AC-T F3 ROOF TRUSS 1 1 mlo-rtonoa Lumber, uantlw, rL. o.1,1u s aep 10 ZVI I full I eK Inousutes, irw— rn .Ian a urgy:ca cula raga 1 ID gR7GTgtGeHxJkx7yRAMor5yENlx-aPyX_WWYAYuOCOCOsTudT42Pt6lzmW?31 SbOzw9oP I1 11-2-8 0-0 Scab e 126.1 F!7. Y Yam 3x3 = IX3 II 3x3 = 3 4 5 14 13 12 34 = 14 II 34 = 3x3 = 3x3 = 4x6 = 6 7 B q7 11 10 9 3x3 = 04 = 3x3 = I 2-9-0 I 530 I t0 S8 I 12.11.8 15A B I 2.91 280 5.2A 2$0 Plate Offsets fX.YI- 11.Edoe.0-1-81 LOADING (psi) SPACING- 2-0.0 CSI. DEFL. in (loc) I/den L/d TCLL 40.0 Plate Grip DOL 1.00 TC 0.56 Ven(LL) 0.16 12-13 999 360 TCDL 10.0 Lumber DOL 1.00 BC 0.73 Ven(CT) 0.21 12-13 874 240 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(CT) 0.04 9 n/a rile BCDL 5.0 Code FBC20171TP12014 Matrix-S LUMBER- BRACING - PLATES GRIP MT20 244/190 Weight 83 lb FT - 20%F, 11 %E TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purbns, BOT CHORD 22 12 No.1(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10*-0 oc bracing. REACTIONS. (lb/size) 17=850/Mechanical, 9=850/Mechanical FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-17=846/0, 8-9=-044/0, 1-2=844/0, 2-3=2011/0, 3.4=2691/0, 4-5=-2691/0, 5-6=2599/0, 6.7=2026/0, 7-8-839/0 BOT CHORD 15-16=0/1584, 14-15=0/2431, 13.14=0/2691, 12-13=0/2691, 11-12=0/2449, 10.11=011580 WEBS 8-10-0/1117. 1-16=0/1123, 7-10=1030/0. 2-16=1030/0, 7-11=0/620, 2-15=0/594, 6-11=589/0, 3-15=583/0, 6.12-0/312, 3-14=0/538, 5-12=338/112 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10.0.0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies QWARNING • Verily design paammters and READ NOTES ON THIS AND INCLUDED N/TEK REFERENCE PAGE W47473 rev. 1003*015 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown. and is for on nhdwedual budding component, no a truss syslem, Before use, the building designer must vent' the applicability of design parameters and property incorporate this design into the overall building design Bracing Indicated is to prevent buekbng of individual truss Web and/or chord members only. Additional temporary and permanent bracing j1r" is sways required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the w[r fabrication, storage, delivery, erection and bracing of basses and truss systems, see ANSVrPI/ Quality Criteria, DS849 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 216 N Lee Street, Suds 312, Alexandria, VA 22314, Tamps, FL 36610 Job Truss Truss Type Oty PlyPark Sq Hms/ Sorrento-AorC 2078 44T129450 P2078AC-T F3G ROOF TRUSS 1 1 Job Reference (ootionah MIV•r IVWO LurnV 'I Ced.eNw, IL. 1x3 11 1x3 II 3x7 = 34 = I5x6 2 3 4 5 20 19 18 17 16 IS 3x3 II 4x5 = 30 = 3x3 II 3x3 = 3x3 = 0" JV 5' al"I J LV 1 / Ml 10" IIIV VSVICS, In"rn Jan l L rage 1 ID gR7GTg1GeHxJkx7yRAMor5yENlx-aPyX V1N6YAYuOCOCOsTudT4zF16JziU?31_SbOzw9oP i 1S8 I Scab - 1 *26.1 3x3 = 3x3 = 3x3 6 7 8 14 13 12 11 tx3 II 1.3 11 3x3 = 4x5 = 4XS = 9 I 2St2 1 3S-0 317,8 1541-8 2b12 a71 D-1-0 12.1.0 ' Plate Offsets (X.Y- I1:Edoe.0.1-81.118:0-t-8.Edoel. 119:0-1-S.Edoel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Weft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.89 Vert(LL) -0.21 14-15 >865 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 SC 0.71 Vert(CT) -0.29 14-15 >633 240 BCLL 0.0 Rep Stress Inv NO WB 0.79 Horz(CT) 0.04 10 n/a n/a BCDL 5.0 Code FBC2017frPI2014 Matnx-S Weight. 87 lb FT = 20%F, 11%E LUMBER- BRACING - TOP CHORD 2x4 SP No 2(flat) TOP CHORD Structural wood sheathing direly applied or 5-2-7 oc purlins, BOT CHORD 2x4 SP DSS(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. REACTIONS. (lb/size) 20=981/Mechanical, 10=888/Mechanical FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-20=1066/0, 9-10=887/0, 1-2=1274/0, 2-3=1274/0, 3.4=1274/0, 4-5=2648/0, 5.6=2936/0, 6-7=-2760/0, 7-8-2137/0, 8-9=885/0 BOT CHORD 18-19=0/1274, 17-18=0/2353, 16 17=0/2353, 15 16=0/2950, 14-15=0/2760, 13-14=0/2760, 12-13=0/2760, 11-12=0/1651 WEBS 4-17=0/353, 1-19=0/1664, 4-18-1429/0. 2-19=51710, 3-18=0/339, 9-11=0/1179, 4-16=0/398, 8-11-1064/0, 5-16=427/0, 8-12=0/676, 7-12-897/0. 6-15=0/417, 6-14=357/0, 7-13=0/380 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0.0 oc and fastened to each truss with 3-10d (0.131' X 3) nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 169 lb down at 3-7-8 on bottom chord. The design/selection of such connection devtce(s) is the responsibility of others. 6) In the LOAD CASE(S) section, bads applied to the face of the truss are noted as front (F) or back (B). LOAD CASES) Standard 1) Dead + Floor Live (balanced): Lumber Increase-1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10.20=10, 1-9-100 Concentrated Loads (Ib) Vert, 17=169(F) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING • VaAy design Pa vmafars and READ NOTES ON MIS AND INCLUDED M/TEK REFERENCE PAGE M7173 ray. IGOM15 BEFORE USE. Design valid for use only with Mrrek* Connectors This design Is based only upon parameters shown, and is for an Individual budding Component, not a truss system. Before use, the building designer must vent' the appl cateday of design parameters and properly incorporate this design into the overall Am building design. Bracing Indicated Is to prevent buttdeng of IndMdual truss web and/or chord members only. Additional temporary and permanent bracing MAwT' is always required for stability and to prevent collapse with posstble personal Injury and property damage. For general guidance regarding the Vl fabrlcatlon, storage, delivery, eracflore and bracing of trusses and truss systems. "a ANSM11 Oualhy Criteria, DS849 and SCSI Building Component 6904 Parke East Blvd. Safety Information avallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply Perk Sq Hms/ Sorrento-AorC 2078 T12944451 P207SAC-T F4 ROOF TRUSS 5 1 all 1010-N Ktaa LVmDer, Vanua, rL. 0-1-8 H H '•3. 14 13 1 34 = o. Z s oep w cv i r mi i eie muusures, inc. rn ,con is w:+a:c cv io rag= i ID LwgEfgAb9YkKIRKdr2TZXPzS7xJ•2bVACrXUUhl2M?O Z?7MoFiHY?iHO81hk?$ww9oO 3x3 = lx3 II tx3 II 3x3 = 2 3 4 5 3x8 = 6 I'N 1 1FAAW6,ZAhL1we ewe YNINEY Y—Y 10 11 1, 1 1WOMEN LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/den Ud TCLL 40.0 Plate Grip DOL 1.00 TC 0.40 Vert(LL) 0.04 8-9 999 360 TCDL 10.0 Lumber DOL 1.00 BC 0.37 Vert(CT) 0.05 8-9 999 240 BCLL 0.0 Rep Stress Inv YES WB 0.30 Horz(CT) 0.01 7 n/a n/a BCDL 5.0 Code FBC2017lrP12014 Matrix-S LUMBER- BRACING- Scale = 1.10 1 7 3x3 II PLATES GRIP MT20 244/190 Weight: 53 lb FT - 20%F, 11 %E TOP CHORD 20 SP No.2(flat) TOP CHORD Structural wood sheathing direly applied or 6-0-0 oc purlins, BOT CHORD 20 SP No.2(flat) except end verticals. WEBS 20 SP No.3(flat) 'Except' BOT CHORD Rigid ceiling directly applied or 10-0-0 oC bracing. 1-12,6.7: 2x4 SP No.2(flat) REACTIONS. (lb/size) 12=529/0.8-0, 7=529/0-3-8 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-12-525/0, 6-7=525/0, 1-2=-455/0, 2-3-1029/0, 3-4=1029/0, 4-5=1029/0, 5-6-474/0 BOT CHORD 10-11=0/865, 9-10=0/1029, 8-9=0/880 WEBS 6-8=0/631, 1-11=0/618, 5-8--566/0, 2-11-571/0, 5-9=0/341, 2-10=0/354 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0.0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies 0 WARMNG • Verily daslpn parameters end READ NOTES ON THIS AND INCLUDED MTEK REFERENCE PAGE MW?4?3 rev. 104MIS BEFORE USE. Design valid for use only web Mnekm connectors. This design is based only upon parameters sham, and is for on individual building component. not a truss system Before use, tiro building designer must vent' the applicability of design parameters and properly incorporate this design unto the overall building design. Bracing Indicated is to prevent buckling of mdMdual truss Web and/or chord members only. Additional temporary and permanent bracing wT is always required for stability and to provers collapse with possible personal injury and property damage. For general guidance regarding the A. fabrication. storage, delivery, erection and bracing of asses and ass systems. see ANSIRP11 Quality Cnterls, DS8a9 and SCSI Building Component 6904 Parke East Bald. Safety Information available from Truss Plate Institute. 218 N Lee Street. Suite 312. Alexandria, VA 22314. Tamps, FL 36610 Job Truss Truss Type Oty Ply Park Sp Hms/ Sor ento AorC 2078 T12944452 IP207BAC-T F4A GABLE 1 1 Job Reference (optionall mto•rionaa LUmDer, oanow, rL. 3x3 II 1x3 II 1 2 i ri 0.1,1u s bep 1 b cut i nru i ex mousures, me. rn dan a uraxdo 4uta rape 1 ID:LwgEfgAb9YkKlRKdr2TZXPzS7xJ-V4 4HPAYN4opcgWabYHWMru9VThzmRoslWLTZ9Jzw9oN Scale=1:17.5 1x3 I I 1x3 I I 1x3 11 / x3 I I 1x3 11 1 x3 I I 3x3 I I 3 4 5 6 7 8 9 16 17 16 34 11 1x3 II tx3 II 15 14 13 114 II tx3 II tx3 II 12 11 10 1 x3 11 1 x3 11 34 11 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/den Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.08 Vert(LL) n/a n/a 999 MT20 2"1190 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(CT) n/a - n/a 999 BCLL 0.0 Rep Stress Inv YES WB 0.03 Holz(CT) 0.00 10 n/a n/a BCDL 5.0 Code FBC2017/TPI2014 Matrix-R Weight: 46 lb FT = 20%F, 11%E LUMBER- BRACING - TOP CHORD 20 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 20 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. OTHERS 2x4 SP No.3(flal) REACTIONS. All bearings 9-6-12. lb) - Max Grav All reactions 250 lb or less at joints) 18, 10, 14, 11. 12, 13. 17, 16, 15 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Gable requires continuous bottom chord bearing. 2) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 3) Gable studs spaced at 1-4-0 oc. 4) Recommend 2x6 strongbacks, on edge, spaced at 10.0.0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING • Vadly daslgn parameters and READ NOTES ON TM AND INCLUDED NITEK REFERENCE PAGE II111-7473 rev. I&OU7015 BEFORE USE. Design vabd for use only with Mrrek® connectors, This design is based only upon parameters shown, and is for an indmdual budding component, not a truss system. Before use. the building designer must venfy the applrcabdrty, of design parameters and property incorporate this design into the overall budding design. Bracing indicated is to prevent buckling of indmdual truss web and/or chord members only. Additional temporary and permanent bracing 11tA.T" is always required for stabdry and to prevent collapse wM possible personal injury and pmpeny damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVrPl1 Ousllty Criteria, DSBae and SCSI Building component 6804 Parke East Blvd Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312. Aterrelldna, VA 22314 Tampa, FL 36610 Job Truss Truss Type Perk Sg Hrml Sonemo-AOIC 2076T1294M53tyPy P2076AGT F5 ROOFTRUSS t bR raro-rr0noa L1lnaxer, tOnOW, M. 0-1-8 H I 1.M I 3x5 = O.1J V a nw 1 J LV 1 / MI I ex mVVJeres. — rn Jan lL —Us , ID•LwgE/gAb9YkKlRKdr2TZXPzS7xJ-xg3Wu6rFx4cBHsgXO1 CwIO_1 uXb8nZy18gG42zw4S4 Sceb 11:196 3x4 = 3x3 = tx3 II tx3 II 3x3 = 3x4 = 3x3 II 2 3 4 5 6 16 7 17 a 3x6 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1,00 TC 0.98 Ven(LL) -0.08 10-11 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.83 Vert(CT) -0.11 10-11 >999 240 BCLL 0.0 Rep Stress Inv NO WB 0.36 Horz(CT) 0.02 9 n/e n/a BCDL 5.0 Code FBC2017/rP12014 Matnx-S Weight. 65 lb FT = 20%F, 1196E LUMBER- BRACING - TOP CHORD 2x4 SP No.1(fIM) TOP CHORD Structural wood sheathing directly applied or 4-10-14 oc puffins, BOT CHORD 20 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling direly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 15=601/1-10.8, 9=963/Mechantoal, 14=117/0-38 Max Grav 15=601(LC 1), 9=1128(LC 8), 14-117(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1034/0, 3-4-1746/0, 4-5=1746/0, 5-6-1746/0, 6-7-1518/0 BOT CHORD 14-15=0/666, 1314=0/666, 12-13=0/1482, 11-12-0/1746, 10-11=0/1833, 9.10=011150 WEBS 7-9=15W/0, 2-15=887/0, 7-10=0/572, 2-13=01529. 6-10=519/0, 3-13=-M/0, 6-11-363/263. 3-12=0/593, 4-12=280/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 or. and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 347 lb down at 8-11-4. and 349 lb down at 10.11-4 on top chord. The design/selection of such connection device(s) is the responsibility of others. 5) In the LOAD CASE(S) section, bads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increasewl.00 Uniform Loads (plf) Veit: 9-15-10. 1-8-100 Concentrated Loads (lb) Ven: 16=201(B) 17=202(13) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING - Vedy, dasign parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE MI.7473 rev. faoo"015 BEFORE USE. Design valid for use only with M7elt® connectors This design is based only upon parameters shown, and is for an IndMdual budding component, not a truss system. Before use, the budding designer must verity the applicability of design parameters and property incorporate this design Into the overall No budding design. Bracing indicated is to provers budding of individual truss web and/or chord members only. Additional temporary and pamranen bracing is always requved for stability and to prayers collapse with possible personal injury and property damage For general guidance regarding the WIM labritatron, storage, delivery, ereciron and bracing of trusses and truss systems, see ANSVrP11 Quality Crherla, DSBa9 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Ins14Ne. 218 N. Lee Street Soae 312. Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oy Py Park Sq Hms/ Sorrento-AorC 2078 Ti2944454 P2078AG-T F6 ROOF TRUSS 2 1 ma-nunua wmuer, oauvw, rL. 10 9 O.1Ju s Jep to cut f ml i eK mousmes, inc. rn Jan 1c V/:4a.z/ zula rage 1 ID:LwgEfgAb9YkKIRKdr2TZXP2S7xJ-_eldWZ1r5xTHg9n6_1 bF6iR51hAExRI1D6Cl2w9oM 0.1-8 3x8 — H 319 = 1-3-0 2 0,0.11 0•10.12 3 rx3 II 4 1x3 II 3x3 II Scab - 1:9.4 LOADING (psf) SPACING- 2-0.0 CSI. DEFL. in loc) I/den Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.13 Vert(LL) 0.00 6 999 360 MT20 2"/190 TCDL 10.0 Lumber DOL 1.00 BC 0.10 Vert(CT) 0.01 6 999 240 BCLL 0.0 Rep Stress Ina YES WB 0.11 Holz(CT) 0.00 5 n/a We BCDL 5.0 Code FBC2017lrP12014 Malrix-S Weight: 26 lb FT = 20%F, 11%E LUMBER- BRACING - TOP CHORD 2x4 SP N0.2(flat) TOP CHORD Structural wood sheathing directly applied or 4-1-12 oc puffins, BOT CHORD 2x4 SP No.2(nat) except end verticals. WEBS 2x4 SP No.3(nat) BOT CHORD Rigid ceiling direly applied or 10-0.0 oc bracing. REACTIONS. (lb/size) 8=211/0-74, 5-211/Mechanical FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10.0.0 oc and fastened to each truss with 3.10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING • verify design psreniaters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE MLL7473 rev. IOW?015 BEFORE USE. Design valid for use only with Mnek® connectors This design is based only upon parameters sham, and is for an indNidual budding ixmp0nenl, not a truss system. Before Use, the building designer must vent' the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent budding of indmdual thus web and/or chord members only Additional temporary and permanent bracing 11U^ rs always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the Ki1N . fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVrPl1 Quality Criteria. DSB4i9 and SCSI Building Component 6904 Puke East Blvd. Safety Information available from Truss Plate Institute. 218 N Lee Street. Suite 312. Alexandria. VA 22314. Tampa. FL 36610 Job Truss Truss Type Park Sq Hms/ Sorrento-AorC 2078 T12944455 P2078AC-T F7 ROOF TRUSS 10ty1 IPly 1 Job Reference (optimal) mto-rionoa Lumber, nenOW. rL. o.10v s aep w cv r r m i en inousmes. rric. rn dan Pic vi:%v.z r cv io rape r ID:gR7GTg1GeHxJkx7yRAMor$yENtx-_efdWZ?r5xTHg9n6_1 bF6igd51AAEIRI?D6Ctw9oM 3x6 = 1 3x6 = 2 1x3 II 3 lx3 II 4 SOeb = 1,9 4 3x3 = 3x3 = e 7 6 5 3x3 11 3x3 11 18A 31i0 2-0-01!-0 LOADING (psf) SPACING- 2-0.0 CSI. DEFL. In loc) Ilden Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.12 Vert(LL) -0.00 7 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.06 Vert(CT) -0.00 7 >999 240 BCLL 0.0 Rep Stress Ina YES WB 0.08 Horz(CT) 0.00 5 We n/a BCDL 5.0 Code FBC2017rrP12014 Matrix-S Weight: 25 lb FT = 200AF, I I%E LUMBER- BRACING - TOP CHORD 20 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, BOT CHORD 20 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) SOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing. REACTIONS. (lb/size) 8-179/Mechanical.5=179/Mechanical FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies QWARMNO • Veifly desi0n panimaters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE ard.7473 n . 14119Yt015 BEFORE USE. Design valid for use only with hifTekm connectors. This design is based only upon parameters shown. and is for an individual building component, not a truss system Before use, the budding designer must verity the applicability of design parameters and property incorporate this design ono the overall building design. Bracing indicated is to prevent buWi ig of individual truss web and/or chord members only. Additional temporary and permanem bracing (1tA:.T' is &Ways ragwred for slabilry and to prevent collapse with possible personal injury and property damage. For general guidance regarding the Mir fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPn Quality Criteria, DSB29 and BCSI Building Component 6904 Parka East Blvd. Safety Information evallable from Truss Plate Institute. 218 N. Lee Street. Suite 312. Alexandria. VA 22314 Tamp. FL 36610 Job Truss Truss Type otter Ply Perk Sq Hires/ Sorrento-AorC 2078 T12944458 P2078AC-T FT1 SPECIAL 1 0It mttt rionoa wmDer, nantlw, r L. 0.1J4 s Jep to cut r mi i ex mouslnes, mc. r n Ian 1z u/.4a.ca zutd rage 1 I D:gR7GTgtGeHxJkx7yRAMor5yE Ntx-wNm02CaFNjBBX_JADP33KXnoXumSex%&CJiDHdzw9oK 2.10.t Sda6 8 2-11 70.71-0 14-11-4 163 4 181 t 8 27-7-13 2a 4-2 2727 29 10 6 2-t0.1 2 8 5 275 2-0 5 4-0-a 1 4-0 2 8 4 2$5 2$5 2$5 2•t0.1 Scale - 1.50.8 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 5x14 = 04 = 150 II US = 1.50 II 010 = 8x14 MT20HS = 4x12 = 3x8 = 1.5x4 II 3x10 = 1.5x4 II 3x10 = 1 2 3 28 27 4 5 6 7 8 28 9 1029 30 11 12 13 2x4 II 4x9 = 20 II 4x12 — 502 = 5x6 = 7x8 = 6x10 = 4x12 = 20 II 7x10 = 4x4 II 2- 1,1 586 8.211 10.11-0 13-11 0 76 3 4 78-11.8 27.7.73 24 2 27&7 29.10-0 2-10.1 2A5 2A 5 2-0S 3 0-0 2 4 4 2A-4 2-0 5 2.5 2.5 2-10.1 LOADING (psf) TCLL 40.0 TCDL 10.0 BCLL 0.0 ' BCDL 5.0 SPACING- 2-0-0 Plate Grip DOL 1.00 Lumber DOL 1.00 Rep Stress Iner NO Code FBC2017lrP12014 CSI. TC 0.99 BC 1.00 WB 0.93 Matrix-S DEFL. in (loc) Udell Led Vert(LL) -0.26 17 >733 360 Vert(CT) -0.39 16 17 >491 240 Horz(CT) 0.01 14 n/a n/a PLATES MT20 MT20HS Weight: 496 lb GRIP 244/190 187/143 FT - 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.1 'Except' TOP CHORD Structural wood sheathing directly applied or 1-4-12 oc purlins, 6-13: 20 SP DSS except end verticals. BOT CHORD 2x6 SP No.1 BOT CHORD Rigid ceiling direly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 *Except* 7-20,7-19: 20 SP No.1 1-24,3.24,3-22,5.22,6-21,8-18,9.17,11-17,11-15,13-15: 2x4 SP NoAD REACTIONS. (lb/size) 25-1756/0-7-4. 14=340110-7-4, 20=15805/0.7-7 Max Uplift 25=218(LC 4), 14=365(LC 5). 20=1838(1-C 8) Max Grav 25=1756(LC 1), 14=4237(LC 2). 20=17511(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-25=1565/202, 1-2=3824/457, 2-3=-3824/457, 3-4=-4070/535, 4-5=4070/535, 5-6=591/5654, 6.7=2118/20913, 7-8=-184/1798, B-9=11159/1220, 9-10=16867/1693, 10-11=16867/1693, 11-12-98111841, 12-13=98111841, 13-14-36821338 BOT CHORD 24-25-33/257, 23-24=705/6310, 22-23=705/6310. 21-22=5654/591, 20.21-20913/2118, 19-20-11422/1111, 18-19=1798/184, 17-18=1220111159, 16-17=1488/16115, 15-16-1488/ 16115, 14-15-50/567 WEBS 8-19=6491/769, 6-20= 7928/942, 7-20=11695/1241, 7-19-1200111857, 2-24=710/109, 323=5/1004, 4-22=2218/317, 5-21-5279/672, 12-15=6441105. 11-16=11/1253, 10-17=2044/294, 9-18=3888/ 498, 1-24=450/3797, 3-24=2638/263, 3-22-2377/209, 5.22=1037/10322, 6-21=1681/ 16197, 8-18-1370/13756, 9-17-519/6058, 11-17-251/1355, 11-15=-6692/ 687, 13-15=840/9812 NOTES- 1) 3-ply truss to be connected together with 10d (0.131'x3") nails as follows, Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows, 2x6 - 2 rows staggered at 0-6-0 oc. Webs connected as follows. 20 - 1 row at 0-7-0 oc, Except member 20.7 2x4 - 1 row at 0-9-0 oc, member 7-19 2x4 - 1 row at 0-9-0 oc, member 2-24 20 - 1 row at 0.9-0 oc, member 3-23 2x4 - 1 row at 0-9-0 oc, member 4-22 2x4 - 1 row at 0-9-0 oc, member 5.21 2x4 - 1 row at 0-9-0 oc, member 12-15 2x4 - 1 row at 0-9-0 oc, member 11-16 2x4 - 1 row at 0.9-0 oc, member 10-17 2x4 - 1 row at 0-9-0 oc, member 9-18 2x4 - 1 row at 0.9-0 oc, member 1-24 2x4 - 1 row at 0-9-0 oc, member 24-3 2x4 - 1 row at 0-9-0 oc, member 3-22 20 - 1 row at 0- 9-0 oc, member 22-5 2x4 - 1 row at 0-9-0 oc, member 6-21 2x4 - 1 row at 0.9-0 oc, member 18-8 20 - 1 row at 0-9.0 oc, member 9-17 2x4 - 1 row at 0-9-0 oc, member 17-11 2x4 - 1 row at 0-9-0 oc, member 1 t-15 2x4 - 1 row at 0.9-0 oc, printed copies of this document are p member 15-13 2x4 - 1 rowat0-9-0 oc. 2) All loads are considered equally applied to all plies, except R noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to not considered signed and sealed and ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. the Signature must be Verified On 3) Wind ASCE 7-10; VuR=140mph ( 3-second gust) Vesd=108mph; TCDL=4.2psf; BCDL-3.Opsf; h-15ft; B= 45ft; L=3011, eave=4n; Cat. any electronic copies 11; Exp B; End., GCpi=0.18; MWFRS (directional); Lumber DOL-1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. CAR'WWAb0-W$ &Wgre paremeras end READ NOTES ON ThU AND INCLUDED NITEK REFERENCE PAGE M0.7473 new 1407/1015 BEFORE USE. I=3 Design valid for use only with MrTekm connectors This design is based only upon parameters shown, and is for an individual budding component, not a truss system. Before use, the budding designer must verity the applicability of design parameters and property incorporate this design into the overall budding design. Bracing indicated its to prevent buciding of individual truss web and/or Gard members only. Additional temporary and pemianem bracing IitA4 its always required for stability and toproverscollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regarding the L1Y5S! fabrication, storage, delivery, erection and bracing of trusses and truss systems, sae ANSIrrPI1 Oualby Criteria, DSB49 and SCSI Building Component 6904 Parke East BMd. Safety Information available from Truss Plate Instaute. 21a N. Lee Street, Suite 312, Alexandria. VA 22314 Tamps, FL 36610 Job Truss Truss Type Oy Ply Park Sq Hms/ Sorrento-AorC 2078 Tt2944456 P2078AC-T FT1 SPECIAL 1 Job Reference (optionall Mid -Florida Lumber, Bartow, FL. 0.130 s Sep 15 2017 MiteK Industries, Inc. Fn Jan 12 07:49:Z9 Zulu Page Z ID:gR7GTgtGeHxJkx7yRAMor5yENlx-wNm02CaFNjBBX JADP33KXnoXumSex\*CJiDHdzW90K NOTES- 6) N/A 7) This truss has been designed for a 10.0 psf bottom chord live bad nonconcurrent with any other live loads. 8) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 218 Ib uplift at joint 25. 365 lb uplift at joint 14 and 1838 lb uplift at joint 20. 10) Girder carries tie-in span(s): 30-0 at 0.0.0 to 7-0-0 at 7-0.0.: 7-0-0 at 22-10-8 to 3-0-0 at 29-10-8.; 27-0-0 from 7-0-0 to 17-0.0; 25-2-8 from 174).0 to 23-0-0 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 840lb down at 8-1-8, 854 Ib down at 10.1-8, 854 lb down at 11-9-8, 854 Ib down at 13-9-8, 854 lb down at 15.9-8, 854 Ib down at 17-9-8, 854 lb down at 19-9-8, 854 Ib down at 21-9-8, 654 lb down at 23-9-8, 854 Ill down at 25-9.8, 854 lb down at 27-9-8. and 169 lb down at 5-1-0, and 971 lb down at 6-1-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (pit) Vert 26-28=-895, 26-30=845, 14-25=10 Concentrated Loads (lb) Vert 14-12 20=226(B) 22=222(B) 17=226(B) 31=39(8) 32=253(B) 33=226(B) 34-226(B) 35-226(B) 36 =226(B) 37=226(B) 38=226(B) 39=226(8) 40=226(B) Trapezoidal Loads (plf) Vert. 1=235-to-26=345, 30=345•to-13=235 0 WARNING • verify design persmere.a and READ NOTES ON THIS AND INCLUDEDWTEK REFERENCE PAGE WF74673 rev. 1 W4015 BEFORE USE. 03 Design valid for use only with MITekS connectors This design is based only upon parameters shovm, and is for an milmdual building component, not a truss system Before use. the building designer must verity the applicability of design parameters and property mcorporete this design into the overall building design. Bnong indicated is to prevent bupitlng of milmduat truss web and/or chord members only. Additional temporary and permanent bracing KNeKINKisalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regard" ru S fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVrPl1 Quality Criteria, DSB-69 and BCSI Building Component 6904 Parke East BNd. Safety Information available from Truss Plate Institute. 218 N Lee Street, suite 312. Alexandria, VA 22314, Tamps. FL 36610 Job Truss Truss Type Oty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944457 P207SAC-T FT2 SPECIAL 1 Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries. Inc. Fri Jan 12 07 49:29 2018 Page 1 ID:LwgEfgAb9YkKfRKdr2TZXPzS7x,NwNm02CaFNjBBX JADP33KXnpruoweyDkCJiDHdzw9oK 3.6-14 7-0-0 10-1.6 13.2-12 16.7-14 20.2.12 3-&14 3S2 3.1.6 3.1-6 3S2 3.&14 Scale - 1:34.2 7x8 = 1.5x4 11 6x8 = 1.5x4 II 7xe = 1.5x4 11 4x8 = 2 15 3 16 17 4 18 5 19 6 7 14 II 6x14 MT20HS = 8x10 MT20KS = 7x8 = 2x4 11 6x10 = 8 II THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 3 t4 7 0 0 10-1.8 13.2-12 1f>7-14 20.2.12 3814 3S2 3.1.8 31 3- .2 3814 LOADING (psf) SPACING- 1-8-0 CSI. DEFL. in (be) I/de0 Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.90 Veri(LL) 0.60 11-12 >399 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.88 Veri(CT) 0.82 11-12 >291 240 MT20HS 187/143 BCLL 0.0 ' Rep Stress Inv NO WB 0.89 Horz(CT) 0.07 8 n/a n/a BCDL 5.0 Code FBC2017/rP12014 Matrix -MS Weight: 332 lb FT = 20% LUMBER- BRACING - TOP CHORD 20 SP DSS 'Except' TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puffins, 5-7: 20 SP No.2 except end verticals. BOT CHORD 2x6 SP DSS BOT CHORD Rigid ceiling directly applied or 10-" oc bracing. WEBS 2x4 SP No.3 *Except* 1-13,7-9,3-13,59: 20 SP No.t REACTIONS. (lb/sae) 14=4419/0.7-4, 8=2866/0-3-8 Max Uplift 14=-628(LC 4). 8=400(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-14=3963/572, 1-2=-13244/1877, 2-3-1324411877, 3-4=23032/3199, 4-5=23032/3199, 5-6=-8641/1203, 6-7=-8641/1203, 7-8-2484/355 BOT CHORD 13-14=123/855, 12-13=3388/24064, 11-12=3388/24064, 10-11 =2456/17683, 9-10=2456/17683, B-9=761530 WEBS 1-13-1821/12864, 3-11-1081/198, 4-11=1907/285, 5-11=83215596. 5-10=65/603, 7-9 =1170/8423, 2-13=766/139, 3-13=1123611591, 59=9389/1321 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except it noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (8), unless otherwise indicated. 3) Wind: ASCE 7-10; Vu11=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf; h=15ft; B=45tt; L=2411; eave=4tt; Cat. 11; Exp B; End., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL-1.60 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 628 lb uplift at joint 14 and 400 lb uplift at joint S. 9) Girder carries tie-in spen(s): 2-4-0 at 0-0-0 to 6-8-0 at 7-0-0. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 847 lb down and 122 lb up at 10-2-0, and 1888 lb down and 273 lb up at 7-0-0. and 1073 lb down and 155 lb up at 9-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING - Verily design parameters end READ NOTES ON THIS AND INCLUDED NITEK REFERENCE PAGE 111,10*7477 rev. 10N5/2015 BEFORE USE. Design valid for use only with MTelrm connectors This design Is based only upon parameters shown, and Is for an milmdual building component, not a truss system. Before use, the building designer must vent' the applicability of design parameters and properly incorporate this design into the overall MR building design. Bracing indicated is to prevent buckling of indmdual truss web and/or chord members only. Additional temporary and permanam bracing is always repwred for stability and to prevent collapse wan possible personal injury and properly damage. For general guidance regarding the .O fabrication, storage, delivery, erection and bracing of trusses and trust systems, see ANSVTP11 Quality Criteria, DS049 and BCSI Building Component 6904 Parke East Bad. Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Nexandna, VA 22314. Tampa, FL 36610 Job Truss Truss Type 01y Ply Park Sq Hms/ Sorrento-AorC 2078 T12944457 P207SAC-T FT2 SPECIAL 1 q Mid-Florlda Lumber, BanOW, FL. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 3-4=207, 4-7=-83, 8-14=-8 Concentrated Loads (lb) Vert: 3-1888 4=847 17=1073 Trapezoidal Loads (plf) Vert: 1-208-10-3=327 tl.1 Ju s Jep 10 Lu17 MI I ex Industnes. Inc. Fn Jan 1 L ur:4ld:JU Lu1B wepe L ID:LwgElgAb9YkKiRKdr2TZXPzS7xJ.PZKoFYbt70J287uMn7alikK bl79NPTtRzRmp4zw9oJ 0 WARNING - Variry design Parsmetars and READ NOTES ON TNIS AND MCLUDED MTTEK REFERENCE PAGE MIF7477 raw. I&W*015 BEFORE USE. Design valid for use only with MRek® connedom This design is based only upon parameters shown, and is for an individual building component. not a tress system. Before use, the buildup designer must vent' the applicability of design parameters and properly incorporate this design into the overall budtlup design Bracing indicated is to prevent budding of individual truss web andror chord members only. Additional temporary and permanent bracing 114'A„ is always required for stability and to prevent Collapse with possible personal injury and properly damage. For general gudance regarding the LYr f1 fabncoron, storage, delivery. erecuon and bracing of trusses and truss systems, see ANSVIPIt OwUty, Criteria, 03"ll and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate InstitNe. 218 N. Lee Street. Suite 312. Alexandria. VA 22314. Tamps, FL 36810 Job Truss Truss Type Oy Py Park Sq Hms/ Sorrento-AorC 2078 T12944458 P207BAC-T FT3 FLOOR 1 1 Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Jan 12 07:49:30 2018 Page 1 ID: L%VEfgAb9YkKfRKdr2TZXPzS7xJ-PZKoFYbt7OJ287uMn7aitkKBPIJ WNeLIRzRmp4zw9oJ 1-10.0 1.10.0 1 U4 = 2 1.5x4 II Scale = 19.5 20 II 4x4 = LOADING (psi) TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 5.0 SPACING- 2-0-0 Plate Gnp DOL 1.00 Lumber DOL 1.00 Rep Stress Incr NO Code FBC2017fTP12014 CS1. TC 0.08 Bc 0.09 WS 0.00 Matrix -MP DEFL. in Vert(LL) -0.00 Vert(CT) -0.00 HOrz(CT) -0.00 loc) Well Ud 4 >999 360 4 >999 240 3 n/a n/a PLATES GRIP MT20 244/190 Weight: 11 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-10-0 oc puffins, BOT CHORD 2x6 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10.00 oc bracing. REACTIONS. (Ib/size) 4=172/0.3.8, 3=177/Mechanical FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Refer to girder(s) for truss to truss connections. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-" oc and fastened to each truss with 3.10d (0.131" X 3') nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 179 lb down at 0.11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 4) In the LOAD CASE(S) section, bads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (p1Q Vert: 1-2-100, 3-4 =10 Concentrated Loads (lb) Vert: 5=179(F) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies 0 WARMNG • Varffy design paramsrars and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE WF7473 rev. 1N0"013 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown. and Is for an individual budding componero, not a truss system. Before use, the buildup designer must vent' the applicability of design parameters and properly incorporate this design into the overall budding design. Bracing indicated its to prevent buckling of individual cast web and/or chord members only. Additional temporary and permanent bracing F.Wussway!required for stability and to prevent collapse with possible personal miury and property damage. For general guidance regarding theN fabrication. storage. delivery, ereggn and bracing of lasses and trust sytlems, see ANSM11 Quality Criteria, DS849 and SCSI Building Component 6904 Parke East Blvd Safety Information available from Truss Plate Institute. 216 N Lee Street, Suite 312. Alexandria, VA 22314. Tamps, FL 36610 Job Truss Truss Type ty Ply Park Sq Hms/ Sorremo-AcrC 2076 T12944459 P2078A6T FTI ROOF TRUSS 1 n N10FItin0a Lumber, aarlaw, FL a, 139 s Nov 13 z9i i Nuiek IndusNes. mt. Fn Jan 1Z 1e.41 SZ Z910 Pape 1 ID:L"EfgAb9YkKfRKdr2TZXP2S7x,LLxU1x2NINsUMlndlmSieLEYB 2CX1gnFmuCWRIzw88z 3.4-5 6$15 I 9-11-4 I 3.4-5 3-2-9 3.4-5 20 II 4x8 = 4x4 = 2x4 Scab - 1:18.4 LOADING (psf) TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 105.0 SPACING- 2-0-0 Plate Grip DOL 100 Lumber DOL 1.00 Rep Stress Ina NO Code FBC2017/rP12014 CSI. TC 0.72 BC 0.75 WB 0.55 Matrix -MS DEFL. in Vert(LL) -0.05 Ven(CT) -0.12 Horz(CT) 0.02 loc) UdeO Ud 6-7 >999 360 6-7 >995 240 5 n/a n/a PLATES GRIP MT20 244/190 Weight: 109 lb FT - 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-6-13 oc puffins, BOT CHORD 2x6 SP No.1 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling direly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=1530/0.7-4, 5=1559/0-5-8 Max Uplift 8=76(LC 4), 5=77(LC 5) Max Grav 8-1825(LC 2), 5=2101(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=326117, 2-3-4487/161, 3-4=412/18 BOT CHORD 7-8=165/4443, 6-7=165/4443, 5-6=161/4487 WEBS 2-8=4295/154, 2-7-0H 124, 3-6=011182, 3-5=4251/150 NOTES- 1) 2-ply truss to be connected together with IOd (0.131"x3") nails as follows: Top chords connected as follows. 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except it noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15f1; B=4511; L=2411; eave=4ft; Cat. II; Exp B, End., GCpi=O 18. MWFRS (directional); Lumber DOL-1.60 plate grip DOL-1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 76 Ile uplift at joint 8 and 77 Ile uplift at joint 5. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 22 lb down and 1 lb up at 8-1-8, and 773 lb down at 444, and 678 lb down at 8-1-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase-1.00, Plate Increase-1.00 Uniform Loads (pit) Vert: 1-4-100, 54 =210 Concentrated Loads (lb) Vert: 11=-46(B) 12-53(F-22, B=31) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING - Vadry design paamaers and READ NOTES ON THIS AND INCLUDED OTEK REFERENCE CAGE a111.7473 m. 10/MDIS BEFORE USE. Design valid for use only wait Mnek® connectors. This design Is based only upon parameters shorn, and is for an mdrvidual building component, netMRatrusssystemBeforeuse, the budding designer must veiny, the applicability of design parameters and properly mwrpome this Onginto the overallbuilding designBrocIngindicatedistopreventbucidrngofmdNldualtrussweband/or chord members only. Additional temporary and permanent bracing IIL.yI^ Is always required for stability and to prevent collapse with possible personal mlury and property damage. For general guidance regarding the 4Yi T! fabrication, sloneg , delivery, erenron and bracing of trussa and truss systems, see ANSVTPN Quality Criteria, OS049 and BCSI Building Component 6904 Parke East BNd. Safety Information available from Truss plate Institute. 218 N. Lee Street, Suite 312, Almridne, VA 22314. Tampa, FL 38610 Job Truss Truss Type oty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944460 P2078AC-T J3 JACK 3 1 all Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries. Inc. Fri Jan 12 07:49:31 2018 Page 1 ID:LwgEfgAb9YkKlRKdr2TZXPzS7x,LUtASuCVuKRvmHTYLg5XPysKsiev63b 1 gdBKLV&w9ol n-0-0 3-0-0 t-0-0 3.0-0 LOADING (PsT) SPACING- 2-0.0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Inv YES BCDL 10.0 Code FBC2017/rP12014 20 11 3-0-0 a tn CSI. DEFL. in loc) I/dell Ud TC 0.25 Vert(LL) 0.01 4-5 999 240 BC 0.14 Verl(CT) 0.01 4-5 999 180 WB 0.00 Horz(CT) 0.01 3 n/a n/a Matrix -MR LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD BOT CHORD 20 SP No.2 WEBS 2x4 SP No.3 BOT CHORD REACTIONS. (lb/size) 5=195/0.8-0, 3=69/Mechanical, 4=28/Mechanical Max Horz 5=78(LC 12) Max Uplift 5=47(LC 12), 3=54(LC 12), 4-5(LC 12) Max Grav 5=195(LC 1), 3=85(LC 17), 4=52(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown Scale a 1.15.7 PLATES GRIP MT20 244/190 Weight: 12 lb FT = 20% Structural wood sheathing directly applied or 3.0.0 oc purlins. except end verticals. Rigid ceiling directly applied or 10.0.0 oc bracing. NOTES- 1) Wind, ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h-15ft; B=45111; L=24ft, eave=oft, Cat. II, Exp B; Pan. Encl., GCpi=0.55; MWFRS (directional) and C-C Exterior(2) -1-0.0 to 2-0-0. Interior(1) 2-0.0 to 2-114 zone:C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live bad nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47 lb uplift at joint 5, 54 lb uplift at joint 3 and 5 lb uplift at joint 4. Printed copies of this document are not considered signed and sealed and the signature must be venfied on any electronic copies AWARNING- Vedly design parameters and READ NOTES ON THIS AND INCLUDEOWTEK REFERENCE PAGE 4111.7473 rev. 1,06"015 BEFORE USE. Wo Design valid for use only with MrFek® conneclors. This design its based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the bud0ing designer must verity the applicability of design parameters and property incorporate this design Into the overall ONbuildingdesign. Bracing indicated is to prevent pudding of individual truss web and/or chord members only Additional temporary and permanent bracing is always reghdred for stability end to prevent collapse wah possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of truass and truss systems, see ANSVTPII Quality Criteria. DS849 and BCSI Building Component 6904 Parke East Bald. Safety Information available from Truss Plate Insiaule. 218 N Lee Street. Suite 312. Nexandna. VA 22314. Tempe. FL 3600 b Truss Truss Type oty Ply Park Sq Hms/ Sorrento-AorC 2078 rP2 T12944461 07BAC-T J7 JACK 26 1 Mid -Florida Lumber, Bartow. FL. 8.130 s Sep 15 2017 MTek Industnes, Inc. Fn Jan 12 07:49 32 2018 Page 1 ID:LwgEIgAb9YkKIRKdr2TZXPzS7xJ-LyRYgEc8feZmOR2luXdmy9POD6uuM/gAvHvAuyzw9oH 1-0-0 7-0-0 1-0-0 7-0-0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 TCDL 10.0 Lumber DOL 1.25 BC 0.54 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=183/Mechanicel, 2=342/0-3.8, 4=90/Mechanical Max Horz 2=141(LC 12) Max Uplift 3=93(LC 12). 2=82(LC 12) Max Grev 3=183(LC 1), 2-342(LC 1), 4=129(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale - 1.218 DEFL. in (loc) I/dell Ud PLATES GRIP Vert(LL) 0.12 4-7 >679 240 MT20 244/190 Vert(CT) -0.24 4-7 >348 180 Horz(CT) 0.00 2 n/a n/a Weight: 24 Ili FT is 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vesd=108mph, TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L-24ft; eave=4f1; Cat. II; Exp B. Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-114 zone;C-C for members and forces d MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will 1d between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 93 lb uplift at joint 3 and 82 lb uplift at joint 2. Printed copies of this document are not considered signed and sealed and the signature must be verified on . any electronic copies O WARNING- verity, design parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE 411/I.7473 rev. I&MOIS BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon perarrrsters shown, and is for an individual budding component. not a truss system Before use, the building designer must vent' the applicability of design parameters and propel incorporate this design into the overan budding design. Brsang indicated is to prevent buc" of uWrviEual truss web srlO/or chord members ony. Additional temporary and permanent bracing NOTisalwaysrequrredforStabilityandtopreventcollapsewithpossiblepersonlmryryandprortyDamage. For general guidance regarding tits fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVIV II Quality Criteria, DSB49 and BCSI Budding Component 69D4 Parke East Blvd. Safety Information available from Truss Plate Insibuts. 218 N Lee Street. Suite 312. Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oy Ply Parts Sq Hmsr Sorrento•AorC 2078 T12944462 P2078AC-T J7T JACK 3 1 iall Mid•Flonda Lumber, Barlow, FL. 8.130 s Sep 15 2017 MTek Industries, Inc. Fn Jan 12 07:49:32 2018 Page 1 ID LwgEfgAb9YkKIRKd2TZXPzS7xJ•LyRYgEc8fe2mOR2luXdmy9PLr6sb"AvHwtuyzw9oH 1 0 0 7-0.0 30 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.86 TCDL 10.0 Lumber DOL 1.25 BC 0.69 BCLL 0.0 ' Rep Stress Inv YES WB 0.00 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MR LUMBER - TOP CHORD 2x4 SP NO-2 BOT CHORD 20 SP N0.2'Except' 3-7: 2x4 SP No.3 REACTIONS. (lb/size) 4=169/Mechanical, 2=346/0-". 5=107/Mechanical Max Hors 2=141(LC 12) Max Uplift 4=79(LC 12),2--"(LC 12), 5=13(LC 12) Max Grav 4=169(LC 1), 2=346(LC 1), 5=126(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Scale - 1:22 9 DEFL. in (loc) Uden Ud PLATES GRIP Verl(LL) 0.19 6 >432 240 MT20 244/190 Verl(CT) -0.32 6 >258 180 HOIz(CT) 0.16 5 We Tire Weight- 26 lb FT - 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-9-12 of: purlins. BOT CHORD Rigid ceiling directly applied or 6." oc bracing. NOTES- 1) Wind ASCE 7-10, Vuh-140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf, h=25ri; B=45f; L-2411, eave=oft; Cat. II, Exp B; Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2) -14)-0 to 2-", Interior(1) 2-0-0 to 6-11-4 zone,C-C for members and forces d MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 4, 81 lb uplift at joint 2 and 13 lb uplift at joint 5. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING - VMIy dasVn parameters and READ NOTES ON THIS AND INCLUDED WrTEK REFERENCE PAGE WF7473 rev. 1aW,2015 BEFORE USE. Design valid for use only with MiTek® constrictors. This design is based only upon parameters shown. and is for an indn+0ual building component, not a truss system. Before use, the building designer must vent' the applicability of design parameters and property incorporate this design into the overall is building design. Bracing indicated is to prevent buckling of individual truss web andfor chord members orgy. Additional temporary and permanent bracing 11tAn rs always required for stability and to prevent erlycollapsewithpossiblepersonalinjuryandpropdamage For general guidance regarding the KNOW fabrication, storage, delivery, erection and bracing of trusses and truss systems, we ANSIRPII Quality Criteria, OS849 and BCSI Building Component GW4 Parke East Blvd. Safety Information available from Trust Plate Institute. 218 N. Lee Street, Suite 312. Alexandria. VA 22314 Tamps, FL 36610 b Truss Truss Type Ply Park SitHms/ Sorrento-AorC 2078 10ty T12944463 078AC-TrP2 KJ2 JACK 1 1 Mid -Florida Lumber, Barlow, FL. 6.] 3U s 5ep 15 ZU1 A Nh I etc Industries, me. I-n San I uI:4V:33 Zu16 rage 1 I D:L"EfgAb9YkKfRKdr2TZXPzS7xJ-pB7xladmOxhdObdxSF87V Nyhl W M_az4K7xgOOPzw9oG 1 S-0 2-4-5 r 1-5-0 2-45 - 2x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/deb Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.14 Verl(LL) 0.00 7 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.04 Verl(CT) 0.00 7 999 180 BCLL 0.0 Rep Stress Ina NO WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=44/Mechanical, 2=202/0-5.11, 4-19/Mechanical Max Horz 2=52(LC 8) Max Uplift 3=14(LC 8), 2=97(LC 8) Max Grav 3=44(LC 1), 2=202(LC 1), 4=37(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Sub = 1.8.6 PLATES GRIP MT20 244/190 Weight: 10 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing direly applied or 2-4-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oC bracing. NOTES- 1) Wind. ASCE 7-10: Vub=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h-25ft, B=45ft; L=24ft; eave=oft; Cat. II; Exp B; End., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom Chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3 and 97 lb uplift at joint 2. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 9 lb up at 1-6-12 and 3 lb down and 9 lb up at 1-6-12 on top chord, and 2 lb up at 1-6-12, and 2 lb up at 1-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, bads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pm Vert: 1-3=60, 4-5=20 Concentrated Loads (lb) Vert: 9=4(F=2, B=2) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING - Varfy, design parsmatars and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGEWI.7473 rev. 1MMIS BEFORE USE. Design valid for use only with Mrek® connectors. This design is based only upon Parameters shown, and is for an individual building component, not a truss system. Before use, the budding designer must verity the applicability of design parameters and property incorporate this design into the overall MR build" design. Bracing indicated is to proven buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing IItA rs always required for stability and to prevent Collapse with possible personal intury and property damage. For general guidance regarding the 3t aa fabrication, storage, delivery, erection and bracing of trusses; and coµsynerns. see ANSVTPII Ovally Criteria, DSB-89 and SCSI Building Component 6904 Parke East Bald. Safety information available it= Truss Plate Instnine, 218 N. Lee Street. Sure 312. Alexandria, VA 22314. Tamps, FL 36610 Job Truss Truss Type Oy Ply Park Sq Hms/ Sorrento-AorC 2078 Job T12944464 P2078AC-T KJ3 JACK 2 Referencet mio-rionaa LUITIDer, 11811OW, rL. 8.130 S 5ep 15 Z017 MtiTek Industries, Inc. Fn Jan 12 07.49:33 2018 Page 1 ID LwgEfgAb9YkK1RKdr2TZXPzS7xJ-p8?xtadmOxhdObdxSF8?VNyhzWK2az4K7xgOOPZW9oG 1 5 0 4-2-15 1S0 4-2.15 1.50 II 4-2-15 LOADING (psf) SPACING- 2-0.0 CS1. DEFL. in loc) I/den Ud TOLL 20.0 Plate Grip DOL 1.25 TC 0.19 Vert(LL) 0.01 4-5 999 240 TCDL 10.0 Lumber DOL 1.25 SC 0.16 Vert(CT) 0.02 4-5 999 180 BCLL 0.0 Rep Stress Inv NO WS 0.00 Horz(CT) 0.01 3 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MR LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD SOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BOT CHORD REACTIONS. (Ib/size) 5=226/0.11-5, 3=84/Mechanical, 4=34/Mechanical Max Horz 5=79(LC 8) Max Uplift 5=124(LC 8), 3=73(LC 8), 4=7(LC 8) Max Grav 5=226(LC 1). 3=84(LC 1), 4=70(LC 3) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Scale = 1.15.4 PLATES GRIP MT20 244/190 Weight 16 Ile FT = 20% Structural wood sheathing directly applied or 4-2-15 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind, ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 8=45ft; L=24ft; eave=4ft; Col. II, Exp B, Part. End, GCpi=0.55; MWFRS (directional), Lumber DOL-1.60 plate gnp DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 124 lb uplift at joint 5, 73 Ile uplift at joint 3 and 7 Ile uplift at joint 4. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 100 Ile up at 1-6-12. and 100 lb up at 1-6-12 on top chord, and 12 lb up at 1-6-12, and 12 Ib up at 1-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert- 1-2=-60, 2-3=-60, 4-5=20 Concentrated Loads (Ile) Vert 6=64(F=32, B=32) 7-10(F=5, B=5) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Q WARNING - Verfly deslpn parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE W7473 rev. 10/=015 BEFORE USE Design valid for use a* WM MITek® connectors This design Is based only upon parameters shown, and is for an individual budding componenL not a truss system. Before use, the buildup designer must verify the applicability of design parameters and properly incorporate this design into the overall t bun" design. Bracing indicated is to prevent buckling of individual truss Web and/or chord members only. Additional temporary and permanent bracing 11l'An rs aWays require0 for s4bdrly and to prevent cogspse WM possible personal Injury and propeM damage. For general guidance regarding the of fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIlIPI7 Quality Criteria, DSB29 and BCSI Building Component 6904 Parke East Blvd. Safety Information available tram Truss Plate Institute. 218 N Lee Street. Suke 312. Alexandria, VA 22314 Tampa. FL 36610 Job Truss Truss Type Oty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944465 P2078AC-T KJ7 JACK 7 1 tall Mid -Florida Lumber, Bartow. FL. 8.130 s Sep 15 2017 M7ek Industries, Inc. Fri Jan 12 07.49:34 2018 Page 1 ID:LwgEfgAb9YkKfRKdr2TZXP2S7xJ•HKZJ5weOBFpTd1870yfE 1aUpovc2JLgTMbPylzw9oF I 1-5-0 I 5-2-5 I 9.10-13 1.5.0 52-5 4-S-S Scab = 1.21.9 20 = 1x4 n 5 30 = S2S 5-25 I 9.1013 4$A LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.38 Ven(LL) -0.03 6-7 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.43 Veri(CT) -0.07 6-7 >999 180 BCLL 0.0 Rep Stress Inv NO WB 0.36 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight 42 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-" oc bracing. WEBS 20 SP No.3 REACTIONS. (lb/size) 4=128/Mechanical, 2-511/0-511, 5=328/Mechanical Max Horz 2=142(LC 8) Max Uplift 4=70(LC 8), 2=148(LC 8), 5=-69(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=775/136 BOT CHORD 2-7=2081708. 6-7=208/708 WEBS 3-7=0/275, 3-6=769/225 NOTES- 1) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; End., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load noneoncurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will nit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 4, 148 lb uplift at joint 2 and 69 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 11 lb up at 1-6-12, 3 lb down and 11 lb up at 1-6-12, 3 lb down and 44 lb up at "12. 3 lb down and 44 Ile up at 4-4-12, and 27 lb down and 77 lb up at 7-2-11, and 27 lb down and 77 lb up at 7-2-11 on top chord, and 2 lb up at 1-6-12, 2 lb up at 1.6-12, 5 lb down at 4-4-12, 5 lb down at "12, and 20 lb down at 7-2-11. and 20 lb down at 7-2-11 on bottom chord. The design/selection o1 such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Undone Loads (ptf) Vert: 1-4-60, 5-8-20 Concentrated Loads (lb) Vert: 13=53(F=27, B=27) 14=4(F=2, B=2) 15=1O(F=5, B=-5) 16=35(F=17, B=17) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Vefy daslpn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE WI.7473 rev. fay M15 BEFORE USE. Design valid for use only with Mnekm connectors. This design is based only upon parameters shown, and is for an individual budding component, not a truss system. Before use, the budding designer must verify the applicability of design parameters and property incorporate this design Into the overall budding design. Bracing indicated is to Prevent buckling of individual truss web and/or chord members only Additional temporary and permanent bracing %t' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the vvr+ fabrication, storage, delivery, erection and bracing of trusses and truss systems, ace ANSVITII Quality Crkerla, DSB49 and SCSI Building Component 69W Parke East Blvd. Safety Information available from Truss Rate Institute, 218 N Lee Street, Sude 312. Alexandria, VA 22314. Tamps, FL 36810 Job Truss Truss Type Oty Ply Park Sq Hmsf Sorrento-AorC 2078 T12944466 P207BAC-T KJ77 SPECIAL 1 1 Job Reference (optionall Mid -Florida Lumber, Barlow, FL. 8.130 S Sep 15 2017 MiTek Industries. Inc. Fri Jan 12 07:49:35 2018 Page 1 ID:I9EL2vgrkv4uEJUYC21FzkFng4X7h1 FfOyZxKFvmJegATao1 tZJgk2oudbF9XUHzw9oE 1-500 I 3d-2 I 6-4-11 9.10.13 I 1 5-0 3-2-2 32-9 3-6-2 40 = 3x4 or 3.2.2 6-4-11 9.10.13 3.2-2 3-2-9 3.6.2 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in hoc) War! Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.82 Verl(LL) 0.23 3-8 521 240 TCDL 10.0 Lumber DOL 1.25 BC 0.92 Vert(CT) 0.47 3-8 253 180 BCLL 0.0 ' Rep Stress Ina NO WB 0.30 Horz(CT) 0.18 6 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matnx-MS LUMBER - TOP CHORD 2x4 SP DSS SOT CHORD 2x4 SP No.2 *Except* 3-9: 2x4 SP No,3, 3-6: 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 5=70/Mechanical, 2=500/0-5-11, 6=367/Mechanical Max Horz 2=142(LC 8) Max Uplift 5=40(LC 8), 2=149(LC 8), 6=101(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=1015/253 BOT CHORD 3-8=312/978. 7-8=313/981 WEBS 4-8=-27/299, 4-7=1057/337 Scale = 1:21.4 PLATES GRIP MT20 244/190 Weight 40 lb FT - 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 5-10-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL-4.2psf; BCDL=3.Opsf, h=25ft; B=45ft; L=24ft; eave=4ft; Cal. II; Exp B, Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL-1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will red between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 40 lb uplift at joint 5, 149 lb uplift at joint 2 and 101 lb uplift at joint 6. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 Ile down and 11 lb up at 1-6-12, 3 lb down and 11 lb up at 1-6-12, and 33 lb down and 76 lb up at 7-2-11. and 33 lb down and 76 lb up at 7-2-11 on top chord, and 2 lb up at 1-6-12. 2 lb up at 1-6-12, at 4-4-12, at 4-4-12, and 2 lb down at 7-2-11, and 2 Ile down at 7-2-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, bads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead ; Roof Live (balanced), Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=60, 3-5=60, 9-10-20, 3-6-20 Concentrated Loads (lb) Vert: 14=-66(F =33, B=33) 15=4(F=2, 8=2) 17=2(F=-1, B=1) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING - verity design panmefors and READ NOTES ON THIS AND INCLUDED MTEK REFERENCE PAGE 11e1-7473 raw. 100"015 BEFORE USE. INDesignvalidforuseonlywithMrrek® connectors This design is based only upon parameter shown, and is for an Individual building component. not a truss system. Before use, the buildup designer must vent' the appYrcy abdof design parameter and property incorporare this design imo the overall building design Bracing indicated is to prevent bucidmng of individual truss web and/or chord member only. Additional temporary and permanent bracing(ISAis shwaysregwredforstabilityandtopreventcollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regarding the $0 fabrication. storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, D5849 and SCSI Building Component 6904 Parke East Bald. Safety Information available from Truss Plare Instaute. 218 N. Lee Street, Surge 312. Alexandria, VA 22314 Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sq Hirst Sorrento-AorC 2078 T12944467 P2078AC-T M1 MONO HIP 1 1 Job Reference (optionall MG-1-1000a Lumber, 118110w, FL. o.1Ju s bep 1u zu1l NuieK incustnes, Inc. rn,Ian tc ur 4%raa cuto rage I ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ4X7hlFf0yZxKFwWagATaol zWyc2s)dbF9XUHzw9oE 1-8.0 3-0-0 1_84 14-0 LOADING (psf) SPACING- 2-" TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr NO BCDL 10.0 Code FBC2017/TPI2014 3 1 5x4 11 to 0 344 CSI. DEFL. in loc) Udell Ud TC 0.41 Vert(LL) 0.01 6 999 240 BC 0.41 Ven(CT) 0.02 4-6 999 180 WB 0.06 Horz(CT) 0.00 4 TIM n/a Matrix -MP LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No 3 BOT CHORD REACTIONS. (lb/size) 1=796/0-3-8, 4=416/Mechanical Max Horz 1-28(LC 8) Max Uplift 1=192(LC 8), 4=110(LC 5) FORCES. (Ili) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-4=298/85 Scab - 1.8.7 PLATES GRIP MT20 244/190 Weight: 14 Ili FT = 20% Structural wood sheathing direly applied or 3-0-0 oc puffins, except end verticals. Rigid ceiling directly applied or 10-0.0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10, Vul1=140mph (3-second gust) Vasd=108mph, TCDL=4.2ps1; 8CDL-3.0ps1; h=251h B=45ft, L=2411, eave=oft, Cat. 11; Exp S; End., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to beanng plate capable of withstanding 192 lb uplift at joint 1 and 110 lb uplift at joint 4. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 7 lb down and 30 Ili up at 141-0 on top chord, and 982 Ili down and 258 Ili up at 1-0-12, and 2 lb down at 14-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face o1 the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-2=-60, 2-3=60, 1-4=20 Concentrated Loads (Ili) Vert, 6=982(8) 7=2(F) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies O WARNING . Vadly daargn Peremsters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE 910-747S rev. faDMIS BEFORE USE. Design valid for use only Whir Llrekib connection. This design is based only upon parameters shown. and b for on indrodual budding component, not a truss "am. Before use. the buildmg designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent bucldbV of indMdual truss Web andror chord members only. Additional temporary and permanent bracing Is shvays required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regardng the fabircown, storage, delivery, erection and bracing of trusses and truss systems, sea ANSVMi quality Criteria, OS049 and SCSI Building Component 6904 Parke East BNd Safety Information ovallable from Truss Plate Inraduie. 218 N. Lee Street. Store 312. Nexandne. VA 22314 Tampa. FL 36610 Symbols I Numbering System I A General Safety Notes PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-tilts' I For 4 x 2 orientation, locate plates 0- 'het' from outside edge of truss. This symbol Indicates the required direction of slots in connector plates. Plate location details available in MiTek 20120 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of theroutput. Use T or I bracing if indicated. BEARING Indicates location where bearings supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89- Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6.4-8 dimensions shown in fl-in-sixteenths Drawings not to scale) 2 3 0 w O U O H BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS IMES Reports: ESR-1311. ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. 0 2012 MiTek® All Rights Reserved MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015 Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the budding designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSUTPI 1. S. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design Is not applicable for use with fire retardant. preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, sae, orientation and location dimensions indicated are minimum plating requirements 12. Lumber used shall be of the species and size, and In all respects, equal to or better than that specked. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, it no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not art or after truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 16. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consuft with project engineer before use. 19. Review all portions of this design (front. back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Oualdy Criteria. i C 1 1 1 1 1, FOR HEAD CLEARANCE BELOW. FLOOR AREA FRAMED BY BLDR. NOTE: SEE ENGINEERING PROFILES FOR SPECIAL CONNECTIONS AND NAILING SCHEDULES. FLOOR SPACING 24" O.C. UNLESS OTHERWISE NOTED. ALL WALLS SHOWN ARE LOAD BEARING AT 9'-4" UNLESS OTHERWISE NOTED. O 2 - HGUS26-2 2-PLY HGRS. d 1& 16 - HHUS46 FLR. HGRS RECORD APPROVED TRUSS ANCHOR BY BUILDER BOTTOM =4x2 TOP = 4x2 TRUSS END DETAIL APPROVED TRUSS ANCHOR BY BUILDER PLUMB CUT OVERHANG HEEL HEIGHT = 2 x 4 BOTTOM = 2 x 4 TOP= 2x4 / TRUSS FNn nFTAII ING SP'NF0R 1 1DEPAR _ 3 5 v o> 8 MID - FLORIDA LUMBER ACQUISITIONS BARTOW, FLORIDA ROOF TRUSSES I LOOR TRUSSES TO' CHORD LIVE 20.0 ITOP CHORD LIVE 400 TO' CHORD DEAD 100 ITOP CHORD DEAD 100 LORD IPSFI THIS TRUSS SYSTEM HIS BEEN DESIGNED WITH LORDS GENERRTEO BY 140 MPH WINDS USING 42 PSF TOP CHORD DEMO LORD AM 30 PSF BOTTOM CHORD DERD LORD 0 MILES FROM HU30CRNE OCERNLINE CRT 11. El?. B OiSCE 7-141 2078 - A or C IPark Square Homes TRAY CLG. OPT P2078AC Sorrento - A or C NA 19-12.171 Bmax Le 25'- 4" 20" 1, 27'- 0" NOTE: SEE ENGINEERING PROFILES FOR SPECIAL CONNECTIONS AND NAILING SCHEDULES. FLOOR SPACING 24" O.C. UNLESS OTHERWISE NOTED. APPROVED TRUSS ANCHOR BY BUILDER BOTTOM =4x2 TOP = 4x2 2x4 Cont. Band r-\ 0 TRUSS END DETAIL o APPROVED TRUSS ANCHOR BY BUILDER PLUMB CUT OVERHANG HEEL HEIGHT = 2 x 4 BOTTOM = 2 x 4 2 / TOP= 2x4 6 Pm'- c --moo 12 TRUSS END DETAIL 0 0 N J L 2 - HUS26 1-PLY HGRS. MID - FLORIDA LUMBER ACQUISITIONS BARTOW, FLORIDA TRUSS LOADING CONDITIONS ROOF TRUSSES FLOOR TRUSSES P CHORD LIUE 200 ITOP CHORD LIVE. 400 100 ITOTHL LORD FSFI 400 ITOTRL LORD O'SFI 550 1 THIS TRUSS SYSTEM MS BEEN DESIGNED WITH LORDS MNERPTED BY 148 I'M WINDS USRG 42 PSF 101' OUtD DERD LOO FIND 30 PSF BOTTOM 0011 QFb LORD 0 MILES FROM HRRRRIU E O[EFKIIE CRT. I I EXP B IFW 7.141 2078 - A or C IPark Square Homes Sorrento - A or C ALL WALLS SHOWN ARE LOAD BEARING AT 9'-4" UNLESS OTHERWISE NOTED. P2078AC 'L '" M fWA 8-7-17 Bmax RECORD COPY City of Sanford Building and Fire Prevention Product Approval Specification Form Permit # it 1 A- 1 1 3 5 Project Location Add V1LDWN SANFORD As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuildin-.ora. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Therma - Tru Single Door FL8871.5 Sliding MI Windows and Doors Series 420 Alum SGD - 2 Panel FL.15332.4 Sectional Clopay Building Products 94rr40-W4 FL15279.20 Roll U Automatic Other 2. Windows Single Hung MI Windows & Doors Series GA 185 Aluminum SH FL 17499.2 Horizontal Slider Casement Double Hun Fixed MI Windows & Doors Series GA 185 Alum Picture Fixed FL15349.1 Awning Pass Through Projected Mullions MI Windows & Doors 5764 Vedcal Alum Mullion FL 15353.2 Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Descri tion Florida Approval # includin decimal 3. Panel Walls Siding James Harding Bldg Products Hardie Panel FL13223.2 Soffits Aluminum Coils, Inc Coils / Soffits FL12194.1 Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles IKO Industries, LTD Asphalt Shingles / Cambridge FL7006.1 Underla ments Warrior Roofing 15 and #30 Roofing Felt FL2346.1 Roofinq Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Please Print) June 2014 Florida Building Code Online Page 1 of 3 i •• Wofesfio6alt 1 ra- s fir.,_ Mf SCIS Home ' Lop In User Registration Hot Topics I Submit Surcharge Stats d Facts { Publications FBC Stall BCIS Site Map Links I Search gym, Product Approval 1 USER: Public User Product Approval Menu > ProduQ or Apol,cation Search > Appiicabon Ust > Application Detail FL # FL8871-R8 Application Type Revision Code Version 2017 Application Status Approved Comments Archived D Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton, OH 43517 419)298-1740 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@)rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan ). King, P.E. R, Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL8871 R8 COI (b) Certificate of Independence.pdf Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 2003 ASTM E1300 1998 ASTM E84 2000 ASTM G26 1995 TAS 201, 202, 203 1994 Florida Licensed Professional Engineer or Architect FL8871 R8 Eauiv (b) Eouivalencv of Standards.pdf http://www.floridabuilding.org/pr/Pi_app_dtl.aspx?param=wGEVXQwtDgty3Ij Wak2nHrp... 2/10/2018 Florida Building Code Online Page 2 of 3 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 10/17/2017 10/17/2017 10/19/2017 12/12/2017 FL # Model, Number or Name Description 8871.1 a. "ClassicCraft Rustic" Series T6 x 8'0 "Impact" Opaque Fiberglass Radius Top Single Door (X) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 II (b) Inst 8871.1.udf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.1 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.1 odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 8871.2 b. "ClassicCraft" or "ClassicCraft 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door (X) - RusGc" Series Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 (b) Inst 8871.2.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.2 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.2.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and Installation instructions. 8871.3 c. "ClassicCraR" or "ClassicCraR 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door with Rustic" Series Sidelite (OX or XO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 II (b) Inst 8871.3.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.3 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.3.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of "3" part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871.4 d. "ClassicCraft" or "ClassicCraft 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door with Rustic" Series Sidelites (OXO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 II (b) Inst 8871.4.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure. N/A Evaluation Reports Other: See INST 8871.4 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.4.odf specific Model and for anyi"er additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of "3" part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871.5 e. "FiberClassic" or "SmoothStar" 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door (X) - Series Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 II (b) Inst 8871.5.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.5 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.5.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. http://www. floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgty3Ii Wak2nHrp... 2/10/2018 Florida Building Code Online Page 3 of 3 8871.6 f. "FiberClassic" or "SmoothStar" 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door with Series Sidelite (OX or XO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 II (b) Inst 8871.6.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.6 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.6.pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of "I" part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871.7 g. "FiberClassic" or "SmoothStar" 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door with Series Sidelites (OXO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 (b) Inst 8871.7.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.7 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.7.Ddf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of "J" part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871.8 FiberClassic", "SmoothStar", 6'0 x 8'0 "Impact" Opaque Fiberglass Double Door (XX) - ssicCraft-or "ClassicCraftrR Inswing or Outswing tic" Series Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 II (b) Inst 8871.8.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.8 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.8.Ddf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 8871.9 1. "FiberClassic", "SmoothStar", 6'0 x 8'0 "Impact" Opaque Fiberglass Double Door with ClassicCraft" or "ClassicCraft Sidelites (OXXO) - Inswing or Outswing Rustic" Series Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 (b) Inst 8871.9.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.9 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.9.Ddf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of ")" part numbers for these sidelites, which have been stained or painted within six months of Installation.) Contact Us : • 2601 Blau Stone Road. Tallahassee FL 32399 Phone: 850-487.1824 The State of Florida is an AA/EEO employer. Copyright 2007.2013 State of Florida.:: Privacy Statement .: Accessibility Statement :: Refund Statement under Florida -law, email addresses are public records. If you do not want your-e-mall address released in response -to a.publk•retgrds request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. It you have any questions, please contact 850 487.1395. "Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record, if you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine it you are a licensee under Chapter 4s5, F.S., please click here . Product Approval Accepts: Credit Card Safe http://v;,A,w.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgty3Ij Wak2nHrp... 2/10/2018 THERMAITRU 41) THERMA TRU DOORS 1 1 8 INOu6TR1AL OR., EOGERTON, OH 4351 7 SMOOTH STAR & FIBER CLASSIC FIBERGLASS SINGLE DOOR INSWING / OUTSWING GENERAL NOTES rrIMPAc r 1. This product has been evaluated and 6 in compliance with the 61h Edition (2017) Florida Balding Code (FBC) structural requirements including the 1Ugh Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used In Ihe'HVHT this product compiles vlith Section 1626 of the Florida Building Code and does not require an Impact resistant covering. 4. When used In areas outside of the HVHr requiring wind bome debris protection, this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an Impact resistant covering. This product meets missile level V and includes Wind Zone 4 as defined In ASTM E 1996 and FBC Sections 1609.1.2.2 3 R301.2.1.2.1. 5. For N stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of this droving require further engineering analysis by a licensed engineer or registered architect. 7. Oulswing configurations using coastal sN item 84 under active doors meet wafer Ihfiltroilon requirements for 1Mr. 8. Inswing configurations and outswing configurations using sill Item 95 under the door do not meet the water Infiltration requirements for the imir and shall be Waited only In non -habitable areas or at habitable locations protected by on overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. TABLE OF CONTENIS DESCRIPTION Typicol elevations, design essures enrol notes DoorpaneletftDoorpaneldafls(Fiber dossic) Horizontal post sectionsVerticalcrosssections 6 Buck and from - 2X buck masonry comhuction 7 1 kome an - I X buck masonry conMruction 8 B of Molerloh IL Components 37.75 MAK rFRAME WIDTH 3U17MAX. PANEL WIDTH x = Id din VERALL DESIGN•PR'ESSURE PSF): Py N' flFM@NSIO pOSI[IVE$ NEG 4i1VE: INSWING 37.75" x 98.00" 80.0 80.0 SMOOTH OUTSWING 37.75" x 96.50" 80.0 80.0 STAR INSWING 37.75" x 98.00" 80.0 80.0 FIBER OUTSWING 37.75 x 96.50" 80.0 80.0- CLASSIC See Sheet 8 for design pressure knitalbro. ro N.T.S. BY.. Dty3 er: LFS rora Ira.: FL-8871.5 7 —L or 8 L DETAIL A -A J b 10 DOOR ANEL cSmoothNor 00000000 42t 0000000 `l 000000000000000 0000/000 0000000 43 00000000000000a00000000 46 0000000000000000000000 O O0000000a0000000 000000000 0 ?. 00000 0000000000000000000000 28.8676OPEN 00000000 45 AREA MAX. 000000000000000000000000000000 DETAIL A•A Panel reinforcement INTERIOR 1 HORIZONTAL CROSS SECTION 2 EXTERIOR 4c Nixj o oa can 1111 8 o i 9m• 0 IL mad12 CZ Cw N INTERIOR V 41 47 1d fCCLa 19 46 45 1 INGE lE IS OOTTO RAII 2 VERTICAL CROSS SECTION 2 NOTE: WOOD DOOR COMPONENTS: PINE (SG >= 0.42) en 0WS ic LFS ; Rem na ra FL-887I.5 ° a n _L OF 8 0 r 3 64 bb 67 61 EXTERIOR 67 bl 63 OF p- —— wo.1 l 1 1 l L DETAIL A -A J d0 DOO EL T d.i DETAIL A -A Ponel reinforcement TYP. 4 CORNERS OF PANEL llill INTERIOR 1 HORIZONTAL CROSS SECTION 3 III Illilll NOTE: WOOD DOOR COMPONENTS: PINE (SG - 0.421 gyp: 4.4 EXTERIOR INTERIOR 2 VERTICAL CROSS SECTION 3 gcan 111 u p .i z°zu m. Rg m a9°•afea W li a °oz dcd CS-) SML N.T.S. on. on OlNS m cwc er•. LFS ; aaeum No-. R m FL-8871.5 °a w _L or N Q 1-1 /r' MIl EM 1.-1.0 1 HORIZONTAL CROSS SECTION 4 Wso approveiswing shownd - lrvmgal INTERIOR EXTERIOR 4 s +tee sr - +e 49 Nff 8 i o Z c{i m C V mD o 0EcccZ o W W = 1-1 /P MIN, FMB. (IYP.) N.T.S. Or. OwS W. LFS RM No- FL-8871.5 u —4— as 8 10 4K N•: a O,yt i o a E 4: INTERIOR EXTERIi'1R rstf Ps u o iD 4•• x g N Z Ca L za 40 9° 6CV i oWoa mnn` q C 10 0 Z Y 5 60 aEC 40 40 60 10 I id g c Yj 60 10 g E o 9 v Q EXTERIOR INTERIOR 9 EXTERIOR INTERIOR v m `" 3 VERTICAL CROSS SECTION& 1 VERTICAL CROSS SECTION 2 VERTICAL CROSS SECTION 5 oulsvwsg co gurotion 5 Oulswkg shown - 5 Nsown w/ M sub -buck see general notes sheet I Gl rc calso approved I., HVHrwofer infatrarion g requirementsa a EXTERIOR INTERIOR EXTERIOR INTERIOR 0 a pN 0 q0 40 INTERIOR EXTERIOR 1' 612 Z o w 6 60 60 N 3 a 1 4 40 I" eke 2 7 3 7 10 A 60 a% i 1: 1 ON e E err ev—Z v' v d v . d u art: 05122108 0 v v v v c o.. • srat N.T.S. v O • • v v . o v oUK er. DWS m 4 VERTICAL CROSS SECTION S VERTICAL CROSS SECTION r6 VERTICAL CROSS SECTION cH, W. LFS 3 a dawing configuration 5 WAg configuration 5 Oulswing configuration OPAR a ,p, see general notes, sheet t for ' HVHTwaferinfdlrotlon see general notes, sheaf I far woferin01ro1bn see general notes sheet 1 Ior11VHZ' woterinfilhalion FL-8871.5 c swn - L or 8 O requirementsrequirementssrequirementss GI ZSo rw 1 TYP. HEAD s JAMBS h TYP. HEAD s E , 9 Ow MASONRY MASONRY JAMBS 5fat n a OPENING OPENING V a 4 ci0 o 'J a FRAME x 2 n O n Ll d o Y 2X BUCK-,,,.2X BUCK a J» jai o- a BUCK ANCHORING HINGE JAMB FRAME ANCHORING SMXE JAMB Mosorvy 2X buck const uclion CONCRETE ANCHOR NOTES: 1. Concrete anchor locations of the comers may be adjusted to maintain the min. edge distance to mortarjolnts. 2. Concrete anchor locations noted os MAX. ON CENTER'must be adjusted to maintain the min. edge distance to mortar Joints, additional concrete anchors may be required to ensure the MAX. ON CENTER' dimenslon ore not exceeded. 3. Concrete anchor fable: ANCHOR ANCHOR MIN.: MIN. CLEARANCE MIN. CLEARANCE EMBEbMENT CTO.MASONRY TO ADJACENT E6GE ::'• :• ANCHOR . . ITW • 1/4" 1-1/4" 2" 4" TAPCON ELCO o 1/4" 1.1/4" 1" 4" ULTRACON I WOOD SCREW INSTALLATION NOTES: 1. Maintain a minimum 5/8" edge distance. I"end distance. 3 1"o.c. spacing of wood screws to prevent the spli fing of wood. HINGE DETAIL LATCH t: DEADBOLT DETAIL ey: DWS a rr: VS 3 rno No-. FL-8871.5 u a 6 or 8 a JK 4 r! zo 1,21 0; HEAD f;; z 6TYP. g; O..:z JAMBS 0 MASONRY 1 aw 5OPENINGmdaIn O CU! Or 2 0 7 17 FRAME 0 1 X BUCK 0a: LATCH 4 DEADSOLT DETAIL V1 0 t 3R HINGE JAMB 3TRIKEJAMB CONCRETE ANCHOR NOTES: FRAME ANCHORING LU I. Concrete anchor locations at the corners maybe cdMfed to maintain the min. Masonry I X buck construction 12 edge distance to mortarMnIL 2. Concrete anchor focallons rioted os'MAX ON CENTER'must be cdIusfed to maintain The nft edge distance to molar Joint& oddIllonal concrete anchors may be required to ensure the MAX. ON CENTER' dimension are not exceeded. J. Concrete anchor table: ANCHOR- ANCHANCHOR. f.- CLEARANCE MIN.CLEARANCE TO MASONRY TOADJACENT' 4YPE..' lu 9M:qfDMEW EDGE-': asc 5/22/08 lrW a m fJ TA/ CON t i BILL OF MATERIALS REM DESCRIPTION MATERIAL A I X BUCK SG >= 0.55 WOOD 8 2X BUCK SG >= 0.55 WOOD C MAX. 1/4' SHIM SPACE WOOD D 1 /4" X 2-3K PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - 3.000 PSI MIN. CONCRETE CONFORMING TO ACI301ORHOLLOWBLOCKCONFORMINGTOASTMC90 CONCRETE G 3/I6" X 3-1/4" PFH ITW CONCRETE SCREW STEEL J 1 /4" X 3-3/,('PFH ITW CONCRETE SCREW STEEL L R 10 X 2-1 IT PFH WOOD SCREW 1.1 S' MIN. EMBEDMENT STEEL 1 INSWING ADJUSTABLE THRESHOLD IS300AJ) ALUM./WOOD 2 INSWING THRESHOLD (IS300HP5) ALUM./COMP. 3 INSWING SELF ADJUST THERMAL BREAK THRESHOLD ISP30M) ALUM./COMP. 4 OUTSWING COASTAL THRESHOLD ALUM./WOOD 5 ' OUTSWING STANDARD THRESHOLD ALUM./WOOD 6 INSWING THRESHOLD ALUM./COMP. 7 DOOR BOTTOM SWEEP VINYL 8 JAMB PINE SG >= 0.42 WOOD 9 JAMB OAK SG >= 0.42 WOOD 10 WEATHERSTRIP FOAM 11 HINGE STEEL 010 X 3/4' PFH SCREW STEEL A9 X 3"PFH WOOD SCREW STEEL LATCH STRIKE PLATE STEELrJ2SECURITYSTRIKEPLATESTEEL 8 X 2-1/2"PFH SCREW STEEL H8 X 3/4"PFH SCREW STEEL KWIKSET SERIES PASSAGE LOCK STEEL 19 KWIKSET SERIES DEADBOLT 660 STEEL 40 SMOOTH STAR DOOR - SEE DOOR PANEL DETAIL SHEET FOR DETAILS 41 DOOR SKIN 0.072" THK. SMOOTH STAR = 6,000 PSI MIN. FIBERGLASS 42 TOP RAIL SMOOTH STAR COMP. 43 LOCK STILE SMOOTH STAR WOOD/LVL 44 HINGE STILE SMOOTH STAR WOOD 45 BOTTOM RAIL SMOOTH STAR COMP. 46 PANEL REINFORCEMENT 0.023" THK. SMOOTH STAR STEEL 47 FOAM CORE POLYURETHANE 60 FIBER CLASSIC DOOR - SEE DOOR PANEL DETAIL SHEET FOR DETAILS 61 DOOR SKIN 0.137" THK. FIBER CLASSIC = 6,000 PSI MIN. FIBERGLASS 62 TOP RAIL FIBER CLASSIC COMP. 63 LOCK STILE FIBER CLASSIC WOOD/LVL 64 HINGE STILE FIBER CLASSIC WOOD 65 BOTTOM RAIL FIBER CLASSIC COMP. 66 PANEL REINFORCEMENT 0.023' THK, FIBER CLASSIC STEEL 67 FOAM CORE POLYURETHANE 4.56' e 1EAD t SIDEIEADtSIDE Jomb 1 THRESHOLD kv*v adpntoble SJIT THRESHOLD hwwhg sell-cepm 5.75' Q 5 1HRESHOLDOubW*V slondard 2 THRESHOLD hasp adjustable 4 RESHOLD Oulswing coastal r 5.83' T- 4 10 OLO MAX. DESIGN PRESSURE _ +/- 50 PSF i 4K 0 9 Z G10, o mZ a o•Z{ E w Z$ O V g 9 nmnonTW CZ 0d Q: 0§ srui: N.T.S. mrt or DWS cxc er: VS FL- 8871.5 r 8 or-! Florida Building Code Online Page I of 6 mom11- SCIS Home t Log In User Registration Hot Topics Submit Surcharge Stan 6 Facts E Publications FBC Stag k BCIS Site Map Unks Search j a r i-"o"ProductApprovalUSER: Public Userdbp Product Approval Menu > ProduR or AODlicatlon Search > Application Ust > Application Detail 9 FL # FL15279-R5 Application Type Revision Code Version 2017 Application Status Approved Comments reapply 11/28/17 Archived Ej Product Manufacturer Clopay Building Products Company Address/Phone/Email 8585 Duke Blvd. Mason, OH 45040 513) 770-6062 mwesterf'ield@clopay.com Authorized Signature Scott Hamilton shamiltonoclopay. com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency intertek Testing Services NA, Inc. Validated By Gary Pfuehler Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year ANSI/DASMA 108 2005 ANSI/DASMA 115 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 Equivalence of Product Standards Certified By Florida Ucensed Professional Engineer or Architect FL 1 S279 RS Eauiv 20170809 - FBC - DASMA 108 eauiv.Ddf FLIS279 R5 Eauiv 20170809 - FBC - DASMA US eauiv.Ddf Product Approval Method Method 1 Option A Date Submitted 08/10/2017 Date Validated 11/29/2017 https://www.floridabuilding.org/pr/car_app_dtl.aspx?param=wGEVXQwtDgv;yVVKJZ1 Q... 2/1/2018 Florida Building Code Online Page 2 of 6 Date Pending FBC Approval Date Approved 12/05/2017 Summary of Products Go to Page = a 0 a Page 1/ 8 0 0 FL # Model, Number or Name Description 15279.1 001 W3-09 DSIE-1A171: 2050, 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; 2051, 2053, 4050, 4051, 4053, 62, interior skin 29 ga. min.) Single -Car (up to 9'0" wide) 64, 65, 62G, 62LG, 64G, SDP38, WINDCODE® W3 Garage Door SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL15279 R5 C CAC Letter with proof of contract and oroof of inspection.pdf Impact Resistant: N/A FLIS279 R5 C CAC W3 Listmp Intertek.odf Design Pressure: +20 PSF/-20 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 RS 11 101655-Revl2.odf windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.2 002 W3-09 DSIE-1A471: GD1SP, Gallery/Artistry/Expressions: 1-3/8" Double -skin Insulated GR1SP, GD1LP, GR1LP, ARiSP, EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) AR1LP, ED1SP, ED1LP, 4132, 2132, Single -Car (up to 9'0" wide) WINDCODE® W3 Garage Door 6132, SFC38, MFC38 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLIS279 R5 C CAC Letter with proof of contract and proof of inspection.odfApproved.for use outside HVHZ: Yes Impact Resistant: N/A FLIS279 R5 C CAC W3 Listing Intertek.pdf Design Pressure: +20 PSF/-21 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FLIS279 R5 II 103952-Rev0l.pdf windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.3 003 W3-09 DSIU-1A171: 9130, Double -skin Insulated PUR (exterior skin 27 ga. min.; 9131, 9133, HDP13, HDPF13, interior skin 27 ga. min.) Single -Car (up to 9'0" wide) HDPL13, 7130, 7131, 7133, 8130, WINDCODE® W3 Garage Door 8131, 8133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of inspection.pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W3 Listino Intertek.pdf Design Pressure: +20 PSF/-20 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 RS 11 104175-Rev0l.pdf windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.4 004 W3-16 DSIE-1A171: 2050, 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; 2051, 2053, 4050, 4051, 4053, 62, interior skin 29 ga. min.) Double -Car (9'2" to 16'0" wide) 64, 65, 62G, 62LG, 64G, SDP38, WINDCODE® W3 Garage Door SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLIS279 RS C CAC Letter with proof of contract and proof of mspection.pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W3 Listing Intertek.pdf Design Pressure: +20 PSF/-21 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 II 101820-Revl3.odf windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windbome Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.5 https://www.floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZI Q... 2/1/2018 Florida Building Code Online Page 3 of 6 005 W3-16 DSIE-1A471: GD1SP, Gallery/Artistry/Expressions: 1-3/8' Double -skin Insulated GR1SP, GD1LP, GR1LP, AR1SP, EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) AR1LP, ED1SP, ED1LP, 4132, 2132, Double -Car (9'2" up to 16'0" wide) WINDCODE® W3 Garage 6132, SFC38, MFC38 I Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other. The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windbome debris regions (ref 1609.1.4 FBC). 15279.6 006 W3-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7233, 8130, 8131, 8133 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure. +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the Impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windbome debris regions (ref 1609.1.4 FBC). 15279.7 148B,SSS,4RST,6RST,4RSF,6RSF 007 W3-16 PAN-2F153: 73, 1500, 75, 190, 84A, 94, 42, 48, 55, 42B, Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure- +20 PSF/-21 PSF Other'. The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windbome debris regions (ref 1609.1.4 FBC). 15279.8 008 W4-09 DSIE-1FI71: 4300, 4301, 4310, 4400, 4401, HOG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of insoection.odf FL15279 RS C CAC W3 Listino Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLI5279 R5 II 104028-ReV01 Ddf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Double -skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double -Car (9'2" to 16'0" wide) WINDCODE® W3 Garage Door Certification Agency Certificate FLI5279 R5 C CAC Letter with proof of contract and proof of insoection.odf FLI5279 R5 C CAC W3 Listing Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 RS II 104168-Rev0l.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) WINDCODE® W3 Garage Door Certification Agency Certificate FLI5279 R5 C CAC Letter with proof of contract and proof of inspection.odf FL15279 RS C CAC W3 Listing Intertek.odf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 RS II 101308-Rev12.Ddf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2" Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODM W4 Garage Door Certification Agency Certificate FL15279 RS C CAC Letter with proof of contract and proof of msoection.Ddf FL15279 RS C CAC W4 Listing Intertek.Ddf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 RS II 101652-B-Rev1I.Ddf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.9 009 W4-09 DSIE-11`471: GD2SP, Gallery/Artistry/Expressions: 2" Double -skin Insulated EPS GR2SP, GD2LP, GR2LP, AR2SP, (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single- AR2LP, ED2SP, ED2LP, 4302, Car (up to 9'0" wide) WINDCODE® W4 Garage Door HDGC, 6202, SFC68, MFI Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 RS C CAC Letter with proof of contract and proof Approved for use outside HVHZ: Yes of insaection.Ddf Impact Resistant: No FLI5279 RS C CAC W4 Listing Intertek.odf Design Pressure: +28 PSF/-29 PSF Quality Assurance Contract Expiration Date Other: The standard glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions FLI5279 R5 II 103969-B-Rev02.pdf https://www.floridabuilding.ortz/t) r_app_dtl.aspx?param=wGEVXQWtDgv;yVVKJZ1Q... 2/1/2018 Florida Building Code Online Page 4 of 6 DOES NOT meet the impact resistant requirement for Verified By: Intertek Testing Services NA, Inc. windborne debris regions. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.10 FHDPJL20, 09 DSIU-1F171: 9200, Double -skin Insulated PUR (exterior skin 27 ga. min.; 203, HDP20, HDPF20, interior skin 27 ga. min.) Single -Car (up to 9'0" wide) 7200, 7201, 7203, 8200, WINDCODE® W4 Garage Door 203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES' comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of inspection.odf FLIS279 R5 C CAC W4 Listing Intertek.Ddf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 R5 II 104183-RevOl.pdf Verified By: Intertek Testing'Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.11 011 W4-09 DSIUO-1K479: Canyon Double Skin Insulated PUR (exterior skin 27 ga. min.; Ridge/Brookstone interior skin 279a. min.) with Overlay Single -Car (up to 9'0" wide) WINDCODE® W4 Garage Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windbome debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 RS C CAC Letter with proof of contract and proof of insoection.pdf FL15279 R5 C CAC W4 Listing Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 RS 1I 104456-Rev0l.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.12 012 W4-09 PAN-2F151: 73, 1500, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 75, 190, 84A, 94, 76, 42, 48, 55, WINDCODE® W4 Garage Door 42B, 48B, 555, 4RST, 6RST, 4RSF, 6RSF, 2RST, GOSS, GDSSV, GRSS, GRSSV, ARSS, ARSSV, EDSS, EDSSV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. 15279.13 013 W4-09 PAN-2F441: G4S, GS4, G4L, GL4, GD4S, GD4L, GR4S, GR4L, G4SV, GS4V, G4LV, GL4V, GD4SV, GD4LV, GR4SV, GR4LV, E4S, E4L, ED4S, ED4L, E4SV, E4LV, ED4SV, ED4LV, SS4, SL4, AR4S, AR4L, SS4V., SL4V, ARASV; AR4LV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the -building code but DOES NOT meet the impact resistant requirement for windborne debris regions. Certification Agency Certificate FL35279 RS C CAC Letter with proof of contract and proof of inspection.Ddf FLIS279 R5 C CAC W4 Listino Intertek.odf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 R5 it 300159-8-Revl6.odf Venfied By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Single - Car (up to 9'0" wide) WINDCODE® W4 Garage Door Certification Agency Certificate FLIS279 R5 C CAC Letter with proof of contract and proof of inspection.pdf FL15279 R5 C CAC W4 Listing Intertek.Ddf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 R5 II 103486-B-RevOS.odf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.14 014 W4-09 SPO-2F449: Grand Steel Pan (min. 24 ga.) with Overlay Single -Car (up to Harbor, Stone Manor 9'0"wide) WINDCODE® W4 Garage Door https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZ1 Q... 2/1/2018 Florida Building Code Online Page 3 of 6 005 W3-16 DSIE-1A471: GD1SP, Gallery/Artistry/Expressions: 1-3/8" Double -skin Insulated GR1SP, GD1LP, GR1LP, AR1SP, EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) AR1LP, ED1SP, ED1LP, 4132, 2132, Double -Car (9'2" up to 16'0" wide) WINDCODE® W3 Garage 6132, SFC38, MFC38 Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of inspection.pdf FLIS279 R5 C CAC W3 Listino Intertek.odf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 RS II 104028-Rev0l.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.6 006 W3-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double -skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double -Car (9'2" to 16'0" wide) WINDCODE® W3 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 RS C CAC Letter with proof of contract and proof of inspection.pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W3 Listing Intertek.odf Design Pressure: +20 PSF/-21 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FLIS279 R5 II 104168-Rev0l.pdf windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windbome Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.7 ' 148B,SSS,4RST,6RST,4RSF,6RSF 007 W3-16 PAN-2F153: 73, 1S00, 75, 190, 84A, 94, 42, 48, 55, 42B, Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the Impact resistant requirement for windbome debris regions (ref 1609.1.4 FBC). 15279.8 008 W4-09 DSIE-11`171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) WINDCODE® W3 Garage Door Certification Agency Certificate FL35279 R5 C CAC Letter with proof of contract and proof of inspection.odf FL15279 RS C CAC W3 Listing Intertek.odf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 RS II 101308-Revl2.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2" Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODE® W4 Garage Door Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of inspection.pdf I FL15279 RS C CAC W4 Listing Intertek.Ddf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 11 101652-B-Revll.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.9 009 W4-09 DSIE-1F471: GD2SP, Gallery/Artistry/Expressions: 2" Double -skin Insulated EPS GR2SP, GD2LP, GR2LP, AR2SP, (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single- AR2LP, ED2SP, ED2LP, 4302, Car (up to 9'0" wide) WINDCODE® W4 Garage Door HDGC, 6202, SPC68, MFC68 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL35279 R5 C CAC Letter with proof of contract and proof Approved for use outside HVHZ: Yes of msoection.Ddf Impact Resistant: No FL15279 R5 C CAC W4 Listing Intertek.odf Design Pressure: +28 PSF/-29 PSF Quality Assurance Contract Expiration Date Other: The standard glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions FLIS279 R5 11 103969-B-Rev02.odf https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZI Q... 2/l/2018 Florida Building Code Online Page 4 of 6 DOES NOT meet the impact resistant requirement for Verified By: Intertek Testing Services NA, Inc. windborne debris regions. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.10 010 W4-09 DSIU-11`171: 9200, Double -skin Insulated PUR (exterior skin 27 ga. min.; 9201, 9203, HDP20, HDPF20, interior skin 27 ga. min.) Single -Car (up to 9'0" wide) HDPL20, 7200, 7201, 7203, 8200, WINDCODE® W4 Garage Door 8201,8203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.11 I011 W4-09 DSIUO-lK479: Canyon Ridge/Brookstone Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof ofinspection.Ddf FL15279 RS C CAC W4 Listing Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15270 R5 II 104183-Rev0l.pdf Verified By: Intertek Testing'Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Double Skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Single -Car (up to 9'0" wide) WINDCODE® W4 Garage Door Certification Agency Certificate FL15279 R5 C CAC Letter with oroof of contract and proof ofinspecbon.pdf FL15279 R5 C CAC W4 Lisbno Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 R5 II 104456-RevOl.odf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.12 012 W4-09 PAN-2F151: 73, 1500, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 75, 190, 84A, 94, 76, 42, 48, 55, WINDCODE® W4 Garage Door 428, 48B, 55S, 4RST, 6RST, 4RSF, 6RSF, 2RST, GOSS, GD5SV, GRSS, GR5SV, ARSS, ARSSV, EDSS, ED5SV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. 15279.13 013 W4-09 PAN-2F441: G4S, GS4, G4L, GL4, GD4S, GD4L, GR4S, GR4L, G4SV, GS4V, G4LV, GL4V, GD4SV, GD4LV, GR4SV, GR4LV, E4S, E4L, ENS, ED4L, E4SV, E4LV, ED4SV, ED4LV, SS4, SL4, AR4S, AR4L, SS4V., SL4V, ARASV; AR4LV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other. The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof ofinspection.pdf FL15279 R5 C CAC W4 Listinb Intertek.odf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 R5 II 300159-B-Revl6.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Single - Car (up to 9'0" wide) WINDCODE® W4 Garage Door Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof ofinspection.pdf FL15279 R5 C CAC W4 Listmo Intertek.Ddf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 R5 II 103486-B-RevO8.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.14 014 W4-09 SPO-2F449: Grand Steel Pan (min. 24 ga.) with Overlay Single -Car (up to Harbor, Stone Manor 9'0"wide) WINDCODE® W4 Garage Door https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZ 1 Q... 2/1 /2018 Florida Building Code Online Page 5 of 6 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-32 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.15 015 W4-16 DSIE-1F171:4300, 4301, 4310, 4400, 4401, HOG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.5 PSF/-25.5 PSF Other. The standard glazing available for this product meets the wind load requirements of the budding code but DOES NOT meet the impact resistant requirement for windborne debris regions. 15279.16 016 W4-16 DSIE-1F471: GD2SP, GR2SP, GD2LP, GR2LP, AR2SP, AR2LP, ED2SP, ED2LP, 4302, HDGC, 6202, SFC68, MFC68 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure. +25.5 PSF/-25.5 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. Certification Agency Certificate FLIS279 R5 C CAC Letter with proof of contract and proof of inspection.pdf FL15279 R5 C CAC W4 Listing Intertek.odf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 R5 11 103549-RevO6.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2" Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double -Car (9'2" to 16'0" wide) WINDCODE® W4 Garage Door Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of inspection.odf FL15279 RS C CAC W4 Listing Intertek.odf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 II 101481-B-Rev13.Ddf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Gallery/Artistry/Expressions: 2" Double -skin Insulated EPS exterior skin 27 ga. min.; interior skin 27 ga. min.) Double - Car (9'2" up to 16'0" wide) WINDCODE® W4 Garage Door Certification Agency Certificate FLIS279 R5 C CAC Letter with proof of contract and proof of insoection.pdf FLIS279 RS C CAC W4 Listing Intertek.odf Quality Assurance Contract Expiration Date OS/21/2028 Installation Instructions FLIS279 R5 II 104029-S-Rev03.odf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.17 017 W4-16 DSIEO-IF479: Coachman/Settlers/Affinity Double Skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Double -Car (up to 16'0" wide) WINDCODE® W4 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLI5279 R5 C CAC Letter with proof of contract and proof of inspection.pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 RS C CAC W4 Listing Intertek.odf Design Pressure: +25 PSF/-25 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 II 103046-RevO7.pdf windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windbome Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.18 018 W4-16 DSIU-1F171: 9200, Double -skin Insulated PUR (exterior skin 27 ga. min.; 9201, 9203, HDP20, HDPF20, interior skin 27 ga. min.) Double -Car (9'2" to 16'0" wide) HDPL20, 7200, 7201, 7203, 8200, WINDCODEO W4 Garage Door 8201, 8203 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside HVHZ: Yes .• Impact Resistant: N/A FLIS279 R5 C CAC Letter with proof of contract and proof of inspection.pdf FLIS279S279 R5 C CAC W4 Listing Intertek.odf Design Pressure: +25.5 PSF/-25.5 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES FLIS279S279 R5 II 104169-RevOl.Ddf Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windbome Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yWKJZ1 Q... 2/1/2018 Florida Building Code Online Page 6 of 6 15279.19 019 W4-16 DSIUO-11<479: Canyon Double Skin Insulated PUR (exterior skin 27 ga. min.; Ridge/Brookstone interior skin 27ga. min.) with Overlay Double -Car (9'2" to126'0"wide) WINDCODE® W4 Garage Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25.5 PSF/-25.5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the Impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of inspection.pdf FL15279 R5 C CAC W4 Listino Intertek.odf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 RS II 104457-Rev02.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.20 020 W4-16 PAN-2F153: 73, 1500, Steel Pan (min. 2S ga.) Double -Car (9'2" to 16'0" wide) 75, 190, 84A, 94, 42, 48, 55, WINDCODE®-W4 Garage Door 4RST, 6RST, 4RSF, 6RSF, GOSS, GD5SV, GRSS, GRSSV, ARSS, ARSSV, EDSS, EDSSV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24 PSF/-24.5 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. Go to Page = Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of hnsoection.odf FL15279 R5 C CAC W4 Listing Intertek.Ddf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279- R5 II 101711-B-RevI5,Ddf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Hert ii 0 Pagel/80 0 Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487.2824 The State of Flonda is an WEED employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. It you do not want your e-mail address released in response to a Public -records request do not send eleCWnic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please Contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 45S, F.S. must provide the Department with an email address If they have one. The emallS provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you area licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M99 F Cns EM Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQ... 2/1/2018 TANNAGE HRW MID PAIL imm, M t MCAMA641DNLK ffEm=imp Mcz CiTmim===1= 6rara._J 0 FFii 61 !•t!• WIl YJ R11'1''7 A O Y [100Au Vt Wollo NOOV OPTIONAL GLAZING MAY BE STANDARD OR IMPACT RESISTANT GLAZING. SEE SECTION B-B FOR OEFAIL4. MAX STANDARD SIZE IS 42-1/2'.16-. IMPACT RESISTANT GLAZING IS 21-3/6•.14-1/6•. 01 IIMIlI IllHE lR lfi®IIIIf ml Trim I `On WL WIm 0 A ` OIOVI OIRSQ IL1m 1001 AOi141 IP.. 000 SM . N'-0' OIA>9C W IR Inl MIQ fIs71M. Yn0 Oc Is716C '-0 Wlaf M/a2 W AlAO Nc10.0 NrAr stossous man a w m re s. s .11!•YmW Gear_Y 70!>Li. SEE SHEET TWO FOR IMPACT RESISTANT CONSTRUCTION DETAIL 'A' AND STANDARD CONSTRUCT DETAIL 'B-; TRACK AND JAMB DETAILS. Y If DENSITY POLYSTYRENE FOAM INSULATION 1-5/16' THICK WITH wm HNRCELL EIACI(ER (INSULATED MODELS ONLY) 25 Gil MIN. CALV. STEEL SKIN WITH A OWED -ON PRIMER. AND A OAKEO-ON POLYESTER TOP COAT APPLIED TO BOTH SIDES OF STEEL SKK nm u a snssa " a m wa Id qa m s o w mw ac i °Ow 0 b a At 0 " ".1. r w mm1 s 0 DoWa0Iqs' v WWI Yad. 00 0eR A AIR 7 YOG A q YO W AOOP Ysml IM0121mm aWaa-vmro uawms A onto warssv w Wv sra Wm al 10 al IM t a s. CA c.A Lc Lc A A. m s v I e I I sr Clopay ng Products °yASON°oN ,UXE 5oY0i/ Ony ( SIJ) 770-46W mww a-p—d- AI NAM. tba1..1 SECTION A -A (SIDE NEWT I f- 2' THICK NDSS 000RL FOR ASOET-1 J' TALL U-M 20 GA. GALV. STEEL MIN. YOLD STRENGTH: 50 KSI Cl J- T 12 GA CALV. STEEL TOP ROLLER BRACKET. EACH BRACKET ATTACHED W/(4) 145 6• SHEET METAL 14 GA. GALV. ROLLER HINGE EACH HINGE FASTENED TO ENO STILES WITH (4) /14.5/6' SHEET METAL SCREWS AND (4) 1/ 4'.3/4' SELF TAPPING SCREWS. SEE NEW V. 0 TALL . 20 CA CALV. STEEL U-BARS IN A 2-1-2-1 PATTERN (I.E. TWO U-EWtS ON BOTTOM SECTION. ONE U-BM ON NEXT SECTION. ETC.). EACH U-BAR ATTACHED 2 ER ( 2 1/4'.J/4' SELF TAPPING SCREWS 13 GA. GyV. E lLS 0ELBOTTOMFRACKET. ATTACHED WITH (2) 1145/6' SHEET METAL SCREWS. ALUMINUM EXTRUSION t VINYL WEATHERSTRIP. DESIGN LOADS: +24.0 PSF Jk -24.5 PSF TEST LOADS: +36.0 PSF t -37.0 PSF W 4 16.0-W x 16.0-H csaroTmA CLASSIC AND CH RP STEEL PAN DOUBLE - CAR. 16'W +24 -24.5 PSF B INIUMEIe 101711 iviab BC AIGOAR IwR• RAM Awl oOms TOOT I"GA145CaAT% mjjvr- N RT" LcAAtGAaIw o wart o v Irra1 7/s'd W salOa OM ! alm0n 1-1 OA WSISII RLaRO). L4G SER17 WW s[ OOIRIImINi 0RR RO1 R071O0) 10 /110Ya( A N91 10amsA aR/ACT. IIGIoONGiL AWa N IOf TIW61al UM 4• m ARaOR SOU.- at a• Q1110R /1AFO 9 1K ONKR31X tall® 111M UE M .Roan an1/4'.r Orm sat" ON Ir Comm ddEO Ri aL awcolm al r ONMO (0-0 aCMA 1' OD6 um m faO RmM TM07a. Ammm WT of MWERSINt 1of m IIWW A 111w1 WWW aarAEt 11 N 0 UP& A001 m M M I05-I01. A IQ)® DOW RA1 ALSO Om10Am m AFFIO.S ALICUM FASIOA96 AIO/al aw a wwwom r SW AaAaO R OOaI N{van (I0 GRII 04Y. im OC iIGL L/ vOIA IS[ am —,la at WL 1,0115 a K GAIN. >Tm 111E31. fOL> I IMPACT RESISTANT ASSEMBLY DETAILS ORAWINO 1 O 171 1 •A SECTION R-R (IMPACT -RESISTANT GLAZING OPTION) G0[ Ot lF OTm11R.[ FiO F FAGv. A laeR11AL ai em SMART 01Osm1 Sso. aM AM FROM GrGCf R®OMI tl®Q WsmRIR R[PSO m1710®W iMIR RIINiai11Oof• ,. 1rR 1flG AAAaK tOaR an i Ism I STANDARD ASSEMBLY0171DET AILS IORAWINO1/ SECTION R-S (NON -IMPACT RESISTANT GLAZING OpnON) aaG 1RAAa 111" Ov GGODRr am 0V= ata¢ Him 11Rf Fina1T mmm Is womm MAR IORTAMf FRYR m alATta 1aGm toot IrtE RETAGOL gyp RR 1rAo sOG1r STANDARD ASSEMBLY CONSTRUCTION: ar11aRL m ao a 1 ACVMX 1.101 A MILAI L OFIaVL IGMC a r1AS12 2 Ora al Haft CCE FLASM a ! RI MIM OWN OR emu ooa ASSOKT OmLq m III cola wn RIM THIS so m1f 1Gn1 as Ww 1d0 SmouTmon or Rc FLOW SNmO am OR "OlimaK a11a1GmEcRVACT R[ SISTINf OOam New" W. OvPM is n AMa SHEET 2 OF 2 SEa7PTM N SHEET ow IS•. 1-O/O' L40 7aS 11 1 t1vm IRK a v. INR GCI m w= \ loaf 0311 D m swm 1 IS' La P Mw O AAM FASIaO To 14 K am 11Na imm na1 IOa[ Rm IRA01 wvc m FASRM m m SRm aM (4) fW: TRACK CONFIGURATION R win wlf 14n/o' aaT lau OW" wn H) no i/• w w.sla /4•• L4• m vwRo oohs ABOVE 1FIE ODOR OPENING DOES NOT AFFECT THE WIND LOAD RATING OF THIS DOOR r Io SA11. ism /1111 am amm sm am M R11O1 in JNm 11a1 t OpOR mTOR et r wL Dan Ala uRDa I( m; Ta Orval OF 09 i/rCflstl AROCMOL DOOM 1WLL K TK u K GAW. lIE6 NO aUOZG UW TOP BRACKET DOUBLE HORQOMAL TESPONI/11' s n9 FFMCBMIAL O fam 1a O[ Ntpo a SKSRIaa Alp M ALg0OA1a[ 1RM aRRIR GLUM W013 sM as low Ap1 (ulpE,p Iq Slppp y101 Slml J) a/ir.1-s/R OOOO uO ICIMV% TRACK 1e1m a TK ORAIRIR LOW NFAOR OGY OPIION 1 t. im rGALvsmmWL TPAOI MSJO aw p TOP a-Ih'•1: a GALV Sim mfm 1SIAn= 66 14) IRiaf wiaan ra WL 11DIL IOOOOWLAYIEdsi. J• asnR[ our 1mR 1RAdi AvuuA:.. Balm 0O14. FTM6' Afa /1 *0 Ml ooae aKa r ULL 1J 4 oily. sTFLL ow SA100T. I'lTfABOO® m ROOD YlO , SCIEft mr arly. aRa TINa TjwmOq" IOl Clopay Gwim MCSO" D ' Building ProductsMASON ON 4B5040 Cnrylnnnv (513) 7i boo 6 I BiSTiiiatiiRml juo i10 to) lliraiivafii 8 1m m a® Ga F t• IY/ a1 oo aa g ) mscuR f1 awL Ror jQ I' FR 0 019A7 FI iG10M FOR 1a1E Dort. • Am IT DESIGN LOADS: + 24.0 PSF & -24.5 PSF TEST LOADS: + 36.0 PSF R -37.0 PSF MPC: PAN- 2Ft 53 1f0m° ° RATm W 4 wa Iml 16.O W aTa R I6• o'H MTD 1/ 3/97 CLASSIC AND CH DOUBLE -CAR. 16'W RP STEEL PAN 24/-24. 3 PSF ORAVN " JACUacaD Sn MWW B auvuc Nuam 101711 BC Florida Building Code Online Page 1 of 4 M__m: .. a BCIS Moore Lop In User Registration ! Hot TophcS Submit Surcharge Stats 6 Facts Publications FBC Starr { SCIS SiteVMap Links Search olic a 6i Product ApprovalraUSER: Public User Pcacla1'2 Product ADDroyal Menu > ProduR or Aoohcatlon Search > Application List > Application Detail FL FL17499-R3 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email MI Windows and Doors 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year AAMA 506 2011 AAMA/WDMA/CSA 101/I.S.2/A440 2008 AAMA/WDMA/CSA 101/I.S.2/A440 2011 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 01/15/2018 Date Validated 01/15/2018 Date Pending FBC Approval Date Approved 01/21/2018 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtCUGgvj Qiz6B... 2/l /2018 Florida Building Code Online Page 2 of 4 Summary of Products FL tf Model, Number or Name Description 17499.1 185 SH 36x84 Fin/Flange Frame IG/SG Impact Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL17499 R3 C CAC MI Windows - 185 SH (Fin) Impact 4).Ddf Impact Resistant: Yes Design Pressure: +55/-55 FL17499 R3 C CAC MI Windows - 185 SH (Fin) Impact (5) Done.odf Other: R-PG55*, Missile Level D, Wind Zone 3. Glass to be FL17499 R3 C CAC MI Windows - 185 SH (Flanae) Impact 3).DdfbeddedinPecora896sealant. FL17499 R3 C CAC MI Windows - 185 SH (Flange) Impact 4).Ddf Quality Assurance Contract Expiration Date 10/17/2018 Installation Instructions FL17499 R3 II 08-02545B.Ddf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513321B-3.pdf Created by Independent Third Party: Yes 17499.2 185 SH 52x72 Fin/Flange Frame IG/SG Single Hung Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC APC(13361)E1726.01-109-47-RO 185 SH(FLG waiver).pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL17499 R3 C CAC MI Windows - 185 SH (Fin) (11).odf FL17499 R3 C CAC MI Windows - 185 SH (Fin) (12).DdfDesignPressure: +60/-60 FL17499 R3 C CAC MI Windows - 185 SH (Flange) Other: R-PG60 10).odf Quality Assurance Contract Expiration Date 10/08/2018 Installation Instructions FL17499 R3 II 08-02549B.pdf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513327B-4.pdf Created by Independent Third Party: Yes 17499.3 185 SH 36x84 Fin/Flange Frame IG/SG Single Hung Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC APC(13363)E1729.01-109-47-RO 185 SH (FLG waiver).DdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 FL17499 R3 C CAC MI Windows - 18S SH (Fin) (13).odf FL17499 R3 C CAC MI Windows - 185 SH (Fin) (14).Ddf FL17499 R3 C CAC MI Windows - 185 SH (FlannelOther: R-PG60* 11). Ddf Quality Assurance Contract Expiration Date 10/17/2018 Installation Instructions FL17499 R3 I] 08-02550B.odf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513328B-S.Ddf Created by Independent Third Party: Yes 17499.4 185 SH 36x71 Fin, Finless, Flange Frame IG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC APC H0462.01-109-47-RO 185 SH 042522).odfApprovedforuseoutsideHVHZ: Yes Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +60/-67 04/25/2022 Other: R-PG60* Installation Instructions FL17499 R3 11 08-03163.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 514082.pdf Created by Independent Third Party: Yes 17499.5 185 SH 52x72 Fin/Flange Frame IG/SG Impact Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC MI Windows - 185 SH (Fin) Impact 2).DdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: Yes FL17499 R3 C CAC MI Windows - 185 SH (Fin) Impact https://www.floridabuilding.orglpr/pr app_dtl.aspx?param=wGEVXQwtDgtCUGgvjQiz6B... 2/1/2018 Florida Building Code Online Page 3 of 4 Design Pressure: +55/-55 3).odf Other: R-PG55, Missile Level D, Wind Zone 3. Glass to be FL17499 R3 C CAC MI Windows - 185 SH (Flange) Impact 2).odfbeddedinPecora896sealant. FL17499 R3 C CAC MI Windows - 185 SH (Flange) Impact 51. Ddf Quality Assurance Contract Expiration Date 10/10/2018 Installation Instructions FL17499 R3 II 08-02544B-I.pdf Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 51332OB-1.Ddf Created by Independent Third Party: Yes 17499.6 185 SH 52x84 Fin/Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ:'No FL17499 R3 C CAC APC(13362)E1725.01-109-47-RO 185 SH(FLG waiver)5-BIG 1-8A 52 1-8X84 R60(100918).odfApprovedforuseoutsideHVHZ: Yes FL17499 R3 C CAC MI Windows - 185 SH (Fin) (10).odfImpactResistant: No FL17499 R3 C CAC MI Windows - 185 SH (Fin) (9).DdfDesignPressure: +60/-60 FL17499 R3 C CAC MI Windows - 185 SH (Flange) (9).DdfOther: R-PG60 Quality Assurance Contract Expiration Date 10/09/2018 Installation Instructions FL17499 R3 11 08-02546B-2.Ddf Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513322E-2.odf Created by Independent Third Party: Yes 17499.7 185 Triple SH 111x72 Fin Frame IG/SG Single Hung 110x72 Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC MI Windows - 185 SH Triple (Fin) Approved for use outside HVHZ: Yes 3).Ddf Impact Resistant: No FL17499 R3 C CAC MI Windows - 185 SH Triple (Fin) Design Pressure: +50/-50 4).Ddf Other: R-PG50' FL17499 R3 C CAC MI Windows - 185 SH Triple (Flange) 3).Ddf FL17499 R3 C CAC MI Windows - 185 SH Triple (Flange) 4).Ddf Quality Assurance Contract Expiration Date 10/20/2018 Installation Instructions FL17499 R3 II 08-02548B.pdf Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513324B-6.odf Created by Independent Third Party: Yes 17499.8 185 Twin SH 106x72 Fin Frame IG/SG Single Hung 105x72 Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC MI Windows - 185 SH Twin (Fin) Approved for use outside HVHZ: Yes 3).odf Impact Resistant: No FL17499 R3 C CAC MI Windows - 185 SH Twin (Fin) Design Pressure: +45/-45 4).odf Other: R-PG45 FL17499 R3 C CAC MI Windows - 185 SH Twin (Flange) 31.Ddf FL17499 R3 C CAC MI Windows - 185 SH Twin (Flange) 4).Ddf Quality Assurance Contract Expiration Date 10/20/2018 Installation Instructions FL17499 R3 II 08-02547B-7.pdf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513323B-7.odf Created by Independent Third Party: Yes Back Nest Contact us : • 2601 Blair Stone Road, Tallahassee FL 32399 Phone: SSo-487.1824 The State of Florida B an AAMEO employer. Copyright 2007.2013 State of Flonda. •: Privacy Statement :: Accessibility Statement :: Refund Statement https://www. floridabuilding. org/prlpr_app_dtl. aspx?param=wGEVXQwtDgtCUGgvj Qiz6B... 2/ 1 /2018 Florida Building Code Online Page 4 of 4 Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity Instead, contact the office by phone or by traditional mad. If you have any questions, please contact 850.487.2395. -Pursuant to Section 455.275(1), Fionda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F S. must provide the Department with an email address If they have one The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to Supply a Personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click h= Product Approval Accepts: goKeen Seilerits"nLT. Kici https:// www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtCUGgvj Qiz6B... 2/1 /2018 NOTES• 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL, 5, WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6 WHERE IX BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. S. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REOUIREO AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10 WIND LOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. I1. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 11 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WINO BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE H8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE, LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. REVISIONS .. I REV I OESCRIPIION I DATE I APPROVED A I REVISED ANCHOR SPACING & CHARTS 107/11/16 I R.L. ' 8 REVISED GLASS 10/02/17 R.L. 15.FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS 17.FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT. 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G-0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2.000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2.000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU-30KSI .048" THICK MINIMUM I TABLE OF CONTENTS 1 SHEET NO. I DESCRIPTION 1 I NOTES 2 - 3 ELEVATIONS 4 - 10 INSTALLATION DETAILS SIGNED: 1211412017 AND LLCMIWINDOWS650 1a IIL0///// WET RET STREET J\5 E NS8 9d, GRATZ. PA 17030-0370 v; •VG f1 0 5SERIES185ALUMINUMSINGLEHUNGWINDOW 52" X 72" NON -IMPACT NOTES STATES OF F•;°(OR10;• ORAMN: arc NO. REv N.G. 08-0022549 B OWA Luis R. Lomas P.E. FL NO.: 62514 w¢ NTS 12/29/14 1 OF 11/111 L.ROGERrOLauSP.E. 1432 NVOOFORD RD LEWlSVILLE MC 27Mn434-M-0609 i0omas@&A Spf com M FR HE 52' MAX FRAME WIDTH 2" MAX r 16" MAX O.C. 2" MAX 2' MAX L 16' O.C. 2" T_ 4X ME GHT 0MAX rf 4 52' MAX FRAME WIDTH 16" MAX O.C. 2" MAX 2 16' on O.C. 72" 1- MAX FRAME HEIGHT 4 X 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW DESIGNER EXTERIOR VIEW FLANGES FINLESS INSTALLATION FLANGES FINLESS INSTALLATION SEE CHART / I FOR SMALLER UNITS REOU/REO ANCHORS SEE CHART f I FOR SMALLER UNITS REOU/REO ANCHORS DESIGN PRESSURE RATING IMPACT RATING t60.OPSF NONE MI WINDOWS AND DOORS, LLC NOTES: 650 WEST MARKET STREET 1. MAXIMUM SASH SIZE. 51" X 36". GRATZ. PA 17030-0370 2. MAXIMUM SASH O.LO.: 47 5/8" X 32 1/2". 3. MAXIMUM FIXED O.L O : 49 3/8" X 32 1/2', SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FLANGE do FINLESS ELEVATIONS DRAW* owc w. N.G. 08-02549 HARDWARE SCHEDULE SCALE NTS 12/29/14 s'w2 OF 11 P) METAL SWEEP LOCK AT 8' FROM EACH END INTERIOR MEETING RAIL L ROBERrOLOMASP.E. 1432 WOOOFORO RO LEWISVILLE, NC 27023 2) BLOCK AND TACKLE BALANCE AT JAMBS 434•66a-0609 lAwM5@sl*M&w cam RVISIORS REV OESCRWMH DATE APPROVED A REVISED ANCHOR SPACING 8: CHARTS 07/11/16 RL 8 1 REVISED GLASS 10/02/17 1 RL CHART #I Number of anchor locations required Frame Frams Wld1h (In) Height 18.00 24.00 J0.00 1 , , J6.00 12.00 48.00 1 52.00 In) Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb 24.00 2 3 3 3 3 3 0 3 4 3 4 3 4 3 30.00 2 3 3 3 3 3 3 3 4 3 4 3 4 3 36.00 2 3 3 3 3 3 3 3 4 3 4 3 4 3 12.00 2 4 3 4 3 4 3 4 4 4 4 4 4 4 18.00 2 4 3 4 3 4 3 4 4 4 4 4 4 4 54400 2 5 3 5 3 5 3 5 4 5 4 5 4 5 60.00 2 5 3 5 3 5 3 5 4 5 4 5 4 5 66.00 2 5 3 5 3 5 3 5 4 5 4 5 1 4 1 5 72.00 2 6 3 6 3 6 3 6 4 6 4 6 1 4 1 6 SIGNED: 1211412017 J' Vft.. I I`l AI r, \ G E N SO' V 9iP f ATAT5 Sjs/ONA LL G\`\ Luis R. Lomas P.E. FL No.: 62514 7 N FIR HE 2" MAX I 10" MAX O C. 2" AX ME GHT 7. 2" MAX 2' MAX — z 10' MAX O.C. T- 52' MAX FRAME WIDTH 10" MAX O.C. 72" MAX FRAME HEIGHT . F/ REMIONS REV OESCRV MN eAIE APPROKO A REASEO ANCHOR SPACING h CHARTS 07/11/16 rR L 2" MAX8 REVISED GLASS 10/02/17 L. CHART#2 Number of anchor locations required Frame Frame Width In Height 18.00 24.00 30.00 36.00 1 42.001 48.00 52.00 In) H 6 S Jamb H d S Jamb H 6 S Jamb H d S Jamb H 6 S Jamb H 6 S Jamb H 6 S Jamb 24.00 3 3 3 3 4 3 5 3 5 3 6 3 6 3 30.00 3 4 3 4 4 4 4 5 4 6 4 6 4 36.00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 42.00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 4&00 3 6 3 6 4 6 5 6 5 6 6 6 6 6 4.00 3 6 3 6 4 6 5. 6 5 6 6 6 6 6 60.00 3 7 3 7 4 7 7 5 7 6 7 6 7 66.00 3 8 3 8 4 8 5 8 5 8 6 8 6 8 72.00 3 8 3 8 4 8 5 8 5 B 6 8 6 8 I 1 ' 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW EXTERIOR VIEW FIN INSTALLATION FIN INSTALLATION SEE CHART d2 FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART I2 FOR SMALLER UNITS REQUIRED ANCHORS DESIGN PRESSURE RATING IMPACT RATING t60.OPSF NONE NOTES: I MAXIMUM SASH SIZE: 51" X 36". 2 MAXIMUM SASH O.L.O.: 47 5/8" X 32 1/2". 3. MAXIMUM FIXED O.L.O.: 49 3/8" X 32 1/2". HARDWARES METAL SWEEP LOCK AT 8' FROM BLOCK AND TACKLE BALANCE AT SIGNED: 1211412017 MI WINDOWS MNDEDOORDOORS, LLC IFLEltoWEST GRATZ, PA 17030-0370 J v,•\G NSA J SERIES 185 ALUMINUM SINGLE HUNG WINDOW z k;'jl(10 5 *~ 52" X 72" NON —IMPACT FIN ELEVATIONS A , STATE OF i ' O4ORIOP• DRAW N.C. owC N0. 08 REv 8 a1E 50022549NTS12/29/14 3 OF 11 L. R06ERTO LOWS P.E. 1432 WOODFORD RO LEMSVILLE. NG 27023 Luis R. Lomas P.E. FL No.: 62514434-eea-0609 441r1ur Oelamaspe Co. RENSSOM ' 1/2" MIN REV OESCRWnDN EDGE DISTANCE A REVISED ANOHOR SPACING k CHARTS WOOD FRAMING OR 2X BUCK B REVISED CU155 BY OTHERS 1 1 /4" MIN. BEOMENT BACKER ROD APPROVED 1/4' MAX SEALANT SHIM SPACE 1 MIN, MENTIIIII # 10 WOOD SCREW EMBBEDED INTERIOR 1 1/2" MIN EDGE DISTANCE 10 WOOD SCREW / WOOD FRAMING J/ OR 2X BUCKEXTERIORNBYOTHERS BACKER ROD k APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS VERTICAL CROSS SECTION SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4" MAX. SHIM SPACE WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH AS TM E2112 1 /4" MAX. SHIM SPACE INTERIOR BACKER ROD do APPROVED EXTERIOR SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION DATE 4PPRMW 07/11/16 R L. 10/02/17 R L. SIGNED: 1211412017 MI DOOR LLC II I1li 650DWEST MARKETD E,T S 0 9,pi GRATZ. PA 17030-0370 r •GENS SERIES 185 ALUMINUM SINGLE HUNG WINDOW 0 X 72" NON —IMPACT INSTALLATION DETAILS T OP`52" yaFLANGE DRAW OB B SS/OIIIA1110 G\`\ Luis R. Lomas P.E. FL No.: 62514 s vE NTS arE 12/29/14 s"M49 OF 11 L. RMERTOLOM4SRE. 14M W000FOR0 RD LEWISVILLE, NO 27=3 434. 6n.OW9 db." &bMM#.aom 1/2" MIN I EDGE DISTANCE MCI STRUCTU BY OTHE APPROVED SEALANT 1/4" MAX. SHIM SPACE REVw5wDN5 - REV OESCRIPIION BATE APPROVED A REVISED ANCHOR SPACING do CHARTS 07/11/16 R.L. 0 REVISED GLASS 10/02/17 R.L. 1/4" MAX. SHIM SPACE 10 SMS OR SELF DRILLING SCREW ly10 SMS OR INTERIORINTERIORSELFDRILLING SCREWS 1 MIN. EDGE DISTANCE T EXTERIOR METAL EXTERIOR STRUCTURE BACKER ROD BY OTHERS & APPROVED I SEALANT I11L JAMB INSTALLATION DETAIL Id METAL STRUCTURE INSTALLATION SILL TO BE SET IN A BED OF APPROVED STRUCTURAL BACKER ROD SEALANT do APPROVED SEALANT 1/4" MAX F SHIM SPACE METAL STRUCTURE MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ. PA 17030-0370 VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS NOTES: DRAW. owwc No I. INTERIOR AND EXTERIOR FINISHES. BY OTHERS, N.G. 08-02549 NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE sr4l NTS 0AlE 12/29/14 1 SNEEI55 OF 11 DESIGNEO IN ACCOROANCE WITH ASTM E2112 1. Rp9ERT0 LOADS P.E 143214000FOR0 RO LEIVISVILLE. NC 27023 434-m-OW9 dbmaS@wbnwvv ox" SIGNED: 1211412017 f t1 I li TAT 5EOF 401110't Luis R. Lomas P.E. FL No.: 62514 RE S10"s 2 1/ MIN. EDGE DISTANCE REV oEscRmnoN are AvvaovEo A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L. CONCRETE/MASONRY BY OTHERS B REVISED CU155 10/02/17 R.L.° 1 1/4" 'MIN. OPTIONAL IX BUCK a EMBEDMENT 1 1/4" MIN. SEE NOTES 3 — 7 X, 4 r EMBEDMENT SHEET 1 1/4 MAX. CONCRETE/MASONRY SHIM SPACE BY OTHERS 1/4" MAX. BACKER ROD SHIM SPACE do APPROVED SEALANT 3/ 16" TAPCON .^ ' 3/ 16" TAPCON e INTERIOR INTERIOR MIN. EDGE v DISTANCE " FSAC KERROOTERIOR OPTIONALIX BUCK EXTERIOR SEE NOTES 3 — 7 SHEET I .IAMB INSTALLATION DETAIL CONCRET& M4SONRY INSTALLATION SILL TO BE SET IN A 8E0 OF NOTES. I INTERIOR AND EXTERIOR FINISHES. BY OTHERS, BACKER ROO APPROVED NOTSHOWNFORCLARITY. do APPROVED STRUCTURAL 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE SEALANT SEALANT DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 12/14/2017 OPTIONAL IX BUCK 1/4" MAX. .. MI WINDOWS AND DOORS, LLC I1111111ii, SEE NOTE 3 — 7 SHEET t SHIM SPACE 650 WEST MARKET STREET g R LO/ GRATZ. PA 17030-0370 GEAIs 9fp yCONCRETE/ MASONRY BY OTHERS SERIES IBS ALUMINUM SINGLE HUNG WINDOW*• 52" X 72" NON —IMPACT 05 spa• = FLANGE INSTALLATION DETAILS TATE OF i rye ORAWN: oWG NO. REV jO•:(ORIOP• J 08 B tv s`r OMA \'`' scxE atE sNEEr549 NTS12/29/14 6 OF 11 j1S VERTICAL CROSS SECTION Luis R. Lomas P.E. CONCRET&MASONRYINSTALLATION 1432W000FORORDLEMSMI.E,AFC 27023 FL No.: 62514 434,srra,OW9 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD APPROVED SEALANT BACKER ROD APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 1/2" MIN EDGE DISTANCE 1/4" MAX. IHIM SPACE 10 WOOD SCREW SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4" MAX. SHIM SPACE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 1 1/4" MIN. EMBEDMENT 1_ 1/2" MIN EDGE DISTANCE g10 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS NENSIONS REv OESCRWMW M1E I APPRMW A REVISED ANCHOR SPACING & CHARTS 07/I I/I6 R.L. B REVISED GLASS 10/02/ 17 R L. 1/4" MAX. SHIM SPACE INTERIOR EXTERIOR BACKER ROO APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ. PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS DRAWN DW6 NO. f 08-02549NTSDA'E 12/29/14 '7 OF 11 L.ROBERTO LOU4S P.E. 14M WOODFORD RD LEWISVILLE. AC 27029 4344N-0609 Ab.As@&bMSp* o SIGNED: 1211412017 ll 1 ! i.. 41 VG E N'y TATE OF q REv 'F•:°(OR10P• \' DIVA j1 G Luis R. Lomas P.E. FL No.: 62514 2 1 /2' MIN. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS e • ' n e OPTIONAL IX BUCK / •a • e' EMBEDMENT SEE NOTES 3 — 7 SHEET 1 — 1/4- MAX BACKER ROD SHIM SPACE APPROVED SEALANT 3/16- TAPCON 1 1/4' MIN. EMBEDMENT CONCRETE/MASONRY BY OTHERS 3/16" TAPCON REVISIONS REV OESCRPTION DATE MPROVEO A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L. 0 REVISED GLASS 10/02/17 1 R.I. OPTIONAL IX BUCK SEE NOTES 3 — 7 SHEET 1 1/4" MAX. SHIM SPACE INTERIOR 2 qlME DISTANCE • EXTERIOR J- BACKER ROD k APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETE41ASONRY INSTALLATION SILL TO BE SET BACKER R00 APPROVED IN A BED OF APPROVED NOTES: I. INTERIOR AND EMRIORFINISHES, BYOTHERS, SEALANT STRUCTURAL SEALANT NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT SY OTHERS TO BE OPTIONAL 1X BUCK 1/4• MAX DESIGNED IN ACCORDANCE WITH ASTM E2112 SEE NOTE 3 — 7 SHIM SPACE SIGNED: 1211412017 SHEET 1 MI AND DOOR DOORS, LLC 1t- 0'' CONCRETE/ MASONRY 6soDOWS WESTco L BY OTHERS a n GRATZ, PA 17030-0370 v ••GENS 9% SERIES 185 ALUMINUM SINGLE HUNG WINDOW*•' 0 5 k= 52" X 72" NON —IMPACT d• '• FINLESS INSTALLATION DETAILS TATE OF ; a 0;p ZORIDt- ow.wN xxe owc No 08 5o2 5a9 REv a iiss ONA VERTICALCROSSSECTIONDA,E NTS12/29/14 9 OF 11 j1E G` CONGRET& MASONRY INS TALLA TION L. ROGERTOLOMASPE 14M HOODFORD RD LEMSV4LE. NC 27023 Luis R. Lomas P.E. 4J43C!• 0609 fOomas®EMTatpe eom FL No.: 62514 APPROVED SEALANT BE FIN I 7/16" MIN j EDGE DISTANCE 1 1/4' MIN. EMBEDMENT 8 WOOD SCREW WOOD FRAMING BY OTHERS 1/4" MAX. SHIM SPACE REV61016 REV DESCRIPTION WE I APPROVED A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L. 0 REVISED GLASS 10/02/17 1 R.L. 11 WOOD FRAMING 1/4' MAX BY OTHERS 1 SHIM SPACE INTERIOR # 8 WOOD SCREW INTERIOR t 1/a' MIN. EMBEDMENT I APPROVED SEALANT EXTERIOR BEHIND FIN 7/ 16' MIN EXTERIOR II III EDGE DISTANCE r 7/16- MIN EDGE DISTANCE APPROVED SEALANT BEHIND FIN CMOCvmr.. VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1/4- MAX 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, SHIM SPACE NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TOBE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET WOOD GRATZ. PA 17030-0370 FRAMING BY OTHERS SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON -IMPACT FIN INSTALLATION DETAILS DRAWN: arc NO. N.G. 08-02549 SCAU NTS I DATE 12/29/14 1 SHEET 10 OF 11 L ROSERTO LOINS P.E. 14M WOOOFORD RO LEWISVILLE. NC 27023 434-M-0609 Abmas®KRnaV@m SIGNED: 12/14/2017 fo 5 TAT E OF ;".2, iO' Fs;:c ORlO; Luis R. Lomas P.E. FL No.: 62514 METAL STRUCTURE BY OTHERS APPROVED SEALANT 1/2" MIN EDGE DISTANCE 1/4" MAX SHIM SPACE 10 SMS OR SELF DRILLING SCREW INTERIOR EXTERIOR BACKER ROC do APPROVEC SEALANT METAL STRUCTURE BY OTHERS VERTICAL CROSS SECTION METAL STRUCTURE IIJSTALLATION NOTES: I. INTERIOR AND EXTERIOR FINISHES. BYOTHERS. NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED W ACCORDANCE WITH ASTM E2112 SILL TO BE SET NABED OF APPROVED STRUCTURAL SEALANT 1/ 4" MAX. SHIM SPACE REV4gNS REV DESCRIPTION OAIE I APPROK0 A REVISED ANCHOR SPACING do CHARTS 07/11/16 R.L. 8 REVISED GLASS 10/02/17 R.L. 1 / 4" MAX. SHIM SPACE p 10 SMS OR I INTERIOR SELF DRILLING SCREWS 1/ 2' -- MIN. EDGE DISTANCE 1 EXTERIOR METAL BACKER ROD STRUCTURE EE APPROVED BY OTHERS SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA • 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON -IMPACT FINLESS INSTALLATION DETAILS DRAW OWC No N. G. 1 08-02549 r TS JOATr 12/29/14 ISH1118 OF 11 L RMERTOLOMASRE. W WOODFORD RO LEMSVXLE NC 2M23 4344M. 0509 dbmw AbmuPrcml SIGNED: 1211412017 NN JR I IL 0 pENs'9J,% TATE OF i0. REv ' F"! 10RV0' N N e i 7SS ONAj1EaG` Luis R. Lomas P.E. FL No.: 62514 2 3/16' 13/I6" FLANGE FRAME HEAD CM-I8501 ALUMINUM 606.7-T5.050' THICK 2 5/ 16' — 3 3/8" Lf---4 FLANGE FRAME SILL CM-16502 ALUMINUM 6063-T5.055' THICK 1 7/8' 2 3I/ 16' 1 FLANGE FRAME JAMB CM•18503 ALUMINUM 6063-TS 050' THICK FINLESS FRAME SILL CM•18554 ALUMINUM 6063-T5.055' THICK 2 3/16' —I 5/16' 1 FINLESS FRAME HEAD CM•18553 ALUMINUM 6063•T5.050' THICK 2 5/16" —1 3 3/4" FIN FRAME SILL CM-18509 ALUMINUM 6063•T5.055' THICK 1 3 2 3/16" FINLESS FRAME JAMB CM-18513 ALUMINUM 6063•T5.050' THICK 2 3/16' ] 2 Fqj FIN FRAME HEAD CM-18508 ALUMINUM 6063-T5.050' THICK 1 7/16' 2 3/8" 1 5/8' — 1 1 /8" 2 5/16" FF 2 3/16" _j 13/4" 2 L LOCK RAIUSTILE SASH BOTTOM RAIL MEETING RAIL FIN FRAME JAMB CM•18505 CM•18555 CM•18504 CM•18510 ALUMINUM 6063•T5.062'THICK ALUMINUM6063•T5.0THICK ALUMINUM 6063•T5.055'THICK ALUM/NUM6067•T5 050'TH/CK 50' I RV I OESCRPIION I are I APPROVED I A I REVISED ANCHOR SPACING & CHARTS 107/11/16 I R.L. ' 8 REVISED GLASS 10/02/17 RL. 5/8" 1/8' ANN. — 1/8" ANN. 1/8" ANN. 090 PVB BY KURARAY METAL REINFORCED BUTYL SPACER EXTERIOR 1 INTERIOR 1/2" BITE SEALANT SETTING BLOCK GLAZING DETAIL SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC 1a 11L0,,// 1 3/8' gyp/ 650 GRATZ.SPA 17030 0370RKETSTREETS SERIES 185 ALUMINUM SINGLE HUNG WINDOW PACT52" xCOMPO 1" 4 15/16" 06126 EECOMPONENTSTATOF GLAZING BEAD SASH STILE 5.c•• F P,• Q: 0R10FsORAwNtnvGN0. 08 02549 REV B CM-18535 CM-18507 RIGID PVC 050' THICK ALUMINUM 6063-T5.050' THICK SNCALGC NTS « 12/29/14 11 OF 11 Luis R. Lomas P.E. FL No.: 62514 L. ROBERTO LOMAS P E. 1432 WOODFORD RO LEMSVILLE. NC 2702J 434.6M-M9 Wwm Florida Building Code Online Page 1 of 3 Iti Fla bpr BCIS Home Log to Use, Registration Mot Topcs submit surcharge Slats a Facts 1 Publications FBC stall BUS site Map Unks Searchd. J a a, Product Approval q fir+ USER: Public User Product Approval Menu > Product or Aooli[atlon Search > Application Ust > ApDIIoHon Detail FL # FL15349-R9 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved n MI Windows and Doors 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Windows Fixed Certification Mark or Usting American Architectural Manufacturers Association Steven M. Unch, PE 2 Validation Checklist - Hardcopy Received Standard Year AAMA 506 2011 AAMA/WDMA/CSA 101/I.S. 2/A440 2008 Method 1 Option A 12/31/2017 12/31/2017 01/04/2018 https://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWI... 1 /31 /2018 Florida Building Code Online Page 2 of 3 FL # I Model, Number or Name Description 15349.1 1 185 PW 73 x 72 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R9 C CAC APC 12786.odf Approved for use outside HVHZ: Yes FL15349 R9 C CAC APC 12787.odf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure. +60/-60 04/03/2018 Other: CW-PG60 Installation Instructions FL15349 R9 II 08-02357B.odf Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL15349 R9 AE 513124B.Ddf Created by Independent Third Party: Yes 15349.2 185 PW 159 x 54 Triple CHS Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R9 C CAC APC 15350.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 01/24/2021 Design Pressure: +55/-55 Installation Instructions Other: R-PG55 FL15349 R9 II 08-02949.odf Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL15349 R9 AE 513783.odf Created by Independent Third Party: Yes 15349.3 185 PW Impact 72 x 72 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R9 C CAC APC 15454.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/25/2021 Design Pressure: +55/-55 Installation Instructions Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FLIS349 R9 II 08-02948.odf consisted of 5/32" tempered exterior - spacer - 5/32" Verified By: Luis R. Lomas, PE 62514 annealed / 0.100 Solutia Saflex HP / 5/32" annealed. Glass Created by Independent Third Party: Yes was bedded in Pecora 896 silicone with 5/8" glass bite. Evaluation Reports FL15349 R9 AE 513782.Ddf Created by Independent Third Party: Yes 15349.4 185 PW Impact 159 x 54 Triple CHS Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLIS349 R9 C CAC APC 8272.odf Approved for use outside HVHZ: Yes FL15349 R9 C CAC APC 8273.odf Impact Resistant: Yes Quality Assurance Contract Expiration Date Design Pressure: +55/-55 01/24/2021 Other: FW-R55, Missile Level D, Wind Zone 3. Glass Installation Instructions consisted of 1/8" annealed exterior - spacer - 3/32" FL15349 R9 II 08-01614B.odf annealed / 0.090 Solutia PVB / 3/32" annealed. Glass was Verified By: Luis Roberto Lomas 62514 bedded in Pecora 896 silicone with 5/8" glass bite. Created by Independent Third Party: Yes Evaluation Reports FL15349 R9 AE 512278B.odf Created by Independent Third Party: Yes 15349.5 185 PW Impact 96 x 60 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLIS349 R9 C CAC APC 7962.odf Approved for use.outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/05/2020 Design Pressure: +55/-55 Installation Instructions Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FL15349 R9 II 08-01613B.odf consisted of 5/32" annealed exterior - spacer - 5/32" Verified By: Luis Roberto Lomas 62514 annealed / 0.100 Solutia Saflex HP / 5/32" annealed. Glass Created by independent Third Party: Yes was bedded in Pecora 896 silicone with 5/8" glass bite. Evaluation Reports FLIS349 R9 AE 512277B.Ddf Created by Independent Third Party: Yes Back Next Contact tK : • 760, Stair Stone Road. Tallahassee FL 32399 Phone: 950J87-1524 The State of Flonda is an AA/EEO employer. Copyright 2007.2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement https://www.floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWl... 1/3 1 /2018 Florida Building Code Online Page 3 of 3 Under Fonda law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, Contact the office by phone or by tradltional mall. If you have any questions, please Contact 850.487.1395. -Pursuant to Section 4SS.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F S. must provide the Department with an email address If they have one The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here . Product Approval Accepts: 009®® 9M Credd Card. Safe https://www.floridabuilding.org/pr/pr app._dtl.aspx?param=wGEVXQwtDgtH8572gvdW1... 1/31/2018 NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2* WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY. CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2- OR GREATER. BUCK SHALL BE SECURELY FASTENED TO MASONRY. CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE: -SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16- OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED. APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED ALUMINUM 6063—T5. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE e6 WOOD. SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4- MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. DESCRV WN NMTE APPROVED REVISED INSTALLATION DEVILS 06/01/15 R.L. REVISED NAME AND ADDRESS 10/27/16 R.L. 15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR IX BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16.FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/I6- TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4- MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17.FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT. 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G-0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2.000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm-2.000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048') FY=33KSI/FU-52KSI OR ALUMINUM 6063—T5 FU-30KSI .048' THICK MINIMUM 20. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN IN SHEET 2. MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ. PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT NOTES TABLE OF CONTENTS DRAW*. 0" No. NEV SHEET N0. DESCRIPTION J.L. 08-02357 B 1 I NOTES 101 NTS O"E 09/03/14 1 '""1 OF 12 2 — 3 ELEVATIONS. CHARTS AND GLAZING DETAILS 4 — 12 INSTALLATION DETAILS L. ROIIERTO LOMAS P.E. 1432 INOWFORD RD LEMSVILLE. NC 27023 4344W-06" .o0mS@&bM&wc0m SIGNED: 11/15/2016 to GENSF •d+ 10; STA E OF N ems` aOR `'taG\ III Luis R. Lomas P.E. FL No.: 62514 72 1/2" MAX FRAME WIDTH 6" MAX --r I$- MAX O.C. 6" MAX L MAX O.C. 71 1/2- MAX FRAME HEIGHT L _ j REFER TO CHARTS SERIES 185 ALUMINUM FIXED WINDOW P I & 02 EXTERIOR VIEW FOR NUMBER OF • ANCHORS REQUIRED 72 1/2" MAX FRAME WIDTH 6" MAX - 18" MAX U.C. - 6" MAX 71 1/2- 18 MAX MAX D.C. FRAME T HEIGHT j j REFER TO CHARTS SERIES 185 ALUMINUM FIXED DESIGNER WINDOW 11 do #2 EXTERIOR VIEW FOR NUMBER OF ANCHORS REQUIRED DESIGN PRESSURE RATING IMPACT RATING t60.0PSF NONE NOTES: 1. MAXIMUM D.L.O.: 69 3/4' X 68 3(4' REVISIONS DESCRIPTION DALE APPRUVM REVISED INSTALLATION DETAILS 06/01/15 R.L. REVISED NAME AND ADDRESS 1 10/27/16 R.L. CHART NI Number of anchors required ftvilhout rigid rollers) Frame Frame w4d46 (In) Height 24.00 30.00 30.00 42.00 46.00 4.00 60.00 1 66.00 72.50 in) H6S mb HSS amb HAS Jamb HAS amb HAS Iamb HAS amb HAS Jamb HAS Jamb His Jamb 24.00 2 L. 2 2 3 2 3 1 2 3 2 4 2 4 2 4 2 5 2 3000 2 2 2 2 3 2 3 2 3 2 4 2 4 2 4 2 S 2 30.00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 S 3 5 3 4L00 2 3 2 3 3 3 3 7 3 3 4 3 5 3 5 3 6 3 46.00 2 3 2 3 3 3 J 3 3 3 3 S 3 6 3 6 3 54.00 2 4 2 4 3 4 J 4 3 4. 4 4 5 4 6 4 7 4 60.00 2 4 2 4 3 4 3 S 3 5 4 5 S S 6 5 7 5 66.00 2 4 2 4 3 5 J S 3 6 6 S 6 6 6 7 6 71.60 2 S 2 S J 5 J 6 3 8 7 5 7 6 7 7 7 CHART e9 Number of anchors required (Wllh rigid fillers) Frame Frame wldlh (In) Height 24.00 30.00 3600 42.00 46.00 SI.00 60.00 1 66.00 7L50 in) HAS Famb HAS Jaab LAS Imb His Jamb HAS Jamb HAS mb HAS Jamb His amb H65 Jamb 24.00 2 2 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 JO 00 2 2 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 36.00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 4 3 5 3 42.00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 4 3 5 7 46.00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 4 3 5 3 4.00 2 4 2 J 4 3 3 4 4 4 4 4 5 4 Sao* 2 2 4 3 J 4 7 4 4 4 4 4 5 4 66.00 2 4 J 3 3 4 4 4 4 4 5 71.60 2 5 2 S J S 3 5 3 5 S 4 5 4 S 1 S S SEE SHEETS 4.7 FOR INSTALLATION DETAILS MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON -IMPACT FLANGE & FINLESS ELEVATION & CHARTS DRAWN: DRC NO. J.L. 08-02357 VALE NTS I DATE 09/03/14 1 S'w2 OF 12 L R06ERTO LOMAS P E. 1432 WO00FORD RD LEWISVXLE. NC 27023 434-666.0609 dLxw@*bm&w.00m SIGNED: 1111512016 R 1 I t o4 ////iJq GENSE' J, r Ik PTATPOF rv i0' oFS Luis R. Lomas P.E. FL No.: 62514 71 I FF Hi 6 MAX 72 1/2- MAX FRAME WIDTH Eri—r 18' MAX O.C. • 18 MAX O.C. 1/2" IAX IGHTIGH y 6" MAX REFER TO CHART #3 -_,,-_ ER/ES 185 ALUMINUM FIXED WINDOW FOR NUMBER OF EXTERIOR VIEW ANCHORS REQUIRED 72 1/2" MAX FRAME WIDTH 6" MAX 18" MAX O.C. 6" MAX 18 MAX O.C. 71 1/2" MAX FRAME HEIGHT REFER TO CHART e3 FOR NUMBER OF SERIES 185 ALUMINUM FIXED DESIGNER WINDOW ANCHORS REQUIRED EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING t60.0PSF NONE NOTES: 1, MAXIMUM D.L.O.. 69 9/I' X 66 yI' REWsnRs , REV OESa.6P110N DAIS I APPROVED A REVISED INSTALLATION DETAILS 06/01/15 ILL 8 REVISED NAME AND ADDRESS 10/27/16 R.L CHART83 Number of anchors required (fin Insialledon Frama width (in) 21.00 30T33 00 62.00 II.00 5a.00 00.00 66.00 72.50 in)HAS amb His amb HAS Pam HAS amb HAS amb H65 amb HAS amb H65 ambF( Ight J J J 1 1 J 1 7 S 5 7 6 J 1 J 1 1 J 5 3 s J e 7 3 3 1 7 1 3 5 5 7 6 42.00] 131111411S 1S1 61 Q.00 11 1 1 11115 151 61 51.00 1 J 1 1 1 1 1 1 1 5 1 5 1. 6 1 i0.00] S J S 1 5 1 5 1 S 5 5 5 5 6 5 i6003 5 7 5 1 5 1 5 1 S S S S S 6 S 71.603 6 7 6 1 6 1 6 1 6 5 6 5 6 6 e SEE SHEET 6 FOR INSTALLATION DETAILS MI WINDOWS AND DOORS, LLC 650 W. MARKFT ST. GRATZ, PA 1 030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FIN ELEVATION & CHART DRAW 0e0 R0. J.L. 08-02357 sr NTS DA'E 09/03/14 S'w3 OF 12 L R08ERTO LOADS P E. 1432 WOODFORD RD LEMSVXLE, ANC 27023 431.666-0609 MDnws®h4masp.ean SIGNED: 11/15/2016 0 6 *= TOF ;eve ZORIOP Luis R. Lomas P.E. FL No.: 62514 1/2" MIN. EDGE DISTANCE WOOD FRAMING 1 1 /4" MIN. OR 2X BUCK EMBEDMENT BY OTHERS I/4" MAX. BACKER ROD SHIM SPACE k APPROVED SEALANT g10 WOOD SCREW EXTERIOR INTERIOR 10 WOOD SCREW RIGID FILLER BACKER ROD do APPROVED 1/4" MAX. SEALANT F SHIM SPACE WOOD FRAMING 1 1/4" MIN OR 2X BUCK EMBEDMENTBYOTHERS 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4" MIN. 1/4" MAX. EMBEDMENT I SHIM SPACE 1/2" MIN. EDGE DISTANCE INTERIOR I 10 WOOD SCREW WOOD FRAMING EXTERIOR OR 2X BUCK BACKER R00BYOTHERS do APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE BY OTHERS BACKER ROD do APPROVED SEALANT EXTERIOR BACKER ROD — APPROVED SEALANT METAL - STRUCTURE BY OTHERS 3/4" MIN. EDGE DISTANCE r 3/4" MIN I EDGE DISTANCE 1 /4" MAX. 8 r SHIM SPACE 10 SMS OR SELF DRILLING SCREW INTERIOR 10 SMS OR SELF DRILLING SCREW RIGID FILLER 1 /4" MAX. SHIM SPACE d 3/4" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION 1 /4" MAX. r SHIM SPACE INTERIOR 10 SMS OR SELF DRILLING SCREWS METAL lp;k fEXTERIOR STRUCTURE BACKER ROD BY OTHERS do APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION RCVISgNS '• REV OESCRIVW" DATE I AMMOVEO A REVISED INSTALLATION DETAILS 06/01/15 R.L. 0 REVISED NAME AND ADDRESS 10/27/16 R.L. NOTES: I INTERIOR AND EXTERIOR FINISHES. BY OTHERS. NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH AS TM E2112 SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW tk• 0y6 51 73" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS WITHOUT FILLERS gip' STATE OF i/.P S F( pR10 . •, \\ DRAWN: Dvw NO. REv 08 e s,°rypil`•`. WAU NTS o'TE 09/03/14 5"EE'47 OF 12 L.ROSERTOLOMASPE. 1472 WVOOFORD RD LEWLSV4.LE. NC 27023 Luis R. Lomas P.E. FL No.: 62514A9.6a1-OM IOXMLWWb Spsmm REv610R5 I REV OESCROTOR I CAFE APPRWEO 2 1/2" MIN. A REVISED INSTALLATION DETAILS 06/01/15 R.L. EDGE DISTANCE I B REVISED NAME AND ADDRESS 10/27/16 R.L. CONCRETE/MASONRY BY OTHERS 1 I/4" MIN. 1 1/4" MIN. EMBEDMENT OPTIONAL IX BUCK EMBEDMENTSEENOTES3 — 7 SHEET 1 CONCRETE/MASONRY BACKER R00 1/4• MAX, BY OTHERS 1/4" MAX. if APPROVED SHIM SPACE SHIM SPACE SEALANT OPTIONAL 1X BUCK SEE NOTES 3 - 7 SHEET I 3/16' TAPCON EXTERIOR INTERIOR 3/ 16" TAPCON INTERIOR 3/I6" TAPCON BACKER ROD h APPROVED SEALANT 1 MAX. 2 1 OPTIONAL 1X BUCK SHIMM SPACE MINN.. SEE NOTE 3 — 7 EDGE SHEET I DISTANCE EXTERIOR CONCRETE/MASONRY BACKEq ROD BY OTHERS 1 1/4" MIN. APPROVED SEALANT EMBEDMENT a•' . JAMB INSTALLATION DETAIL CONCRETEANASONRY INSTALLATION 2 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETE/MASONRY INSTALLATION SIGNED: 11/15/2016 MI WIND DOORS, LLCoWw. MNDK 5 GRATZ. PA 17030 GENSF d+% NOTES. SERIES 185 ALUMINUM FIXED WINDOW o 5 • * I. INTERIOR AND EXTERIOR FINISHES, BY OTHERS. 73" X 72" NON —IMPACT t• 02 jNOTSHOWNFORCLARITY. FINLESS INSTALLATION DETAILS WITHUT FILLERS 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 DRAW* 7No REv 08 SOE2E357 e i/S ONASCALEarENTS09/03/14 5 OF 12 L RMRr0LOM4SP.E II32 WOODFORD RD LEWISVXLE, NC 27023 Luis R. Lomas P.E. FL No.: 62514 IN6ts-0609 dbmn &Uma;ps oom WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD APPROVED SEALANT EXTERIOR BACKER ROD APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 1/2" MIN. EDGE DISTANCE 1 1/4' MIN. r EMBEDMENT 1/4' MAX. SHIM SPACE RIGID FILLER 10 WOOD SCREW INTERIOR 10 WOOD SCREW RIGID FILLER 1/4' MAX. SHIM SPACE MIN. EMBEDMENT 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4" MIN. 1/4" MAX. EMBEDMENT I SHIM SPACE J f RIGID FILLER 1/2" MIN. EDGE DISTANCE I INTERIOR 10 WOOD SCREW WOOD FRAMING EXTERIOR OR 2X BUCK BACKER RODBYOTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE BY OTHERS BACKER ROD APPROVED SEALANT EXTERIOR BACKER ROD APPROVED SEALANT METAL STRUCTURE BY OTHERS 3/4' MIN. EDGE DISTANCE r 3/4" MIN I EDGE DISTANCE 1/4" MAX. 8 r SHIM SPACE f:::::'_ RIGID FILLER 10 SMS OR SELF DRILLING SCREW INTERIOR 10 SMS OR SELF DRILLING SCREW RIGID FILLER 1/4' MAX, SHIM SPACE F' 3/4' MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION 1/4- MAX. r SHIM SPACE RIGID FILLER INTERIOR J10 SMS OR SELF DRILLING SCREWS EXTERIOR METAL STRUCTURE BACKER ROD BY OTHERS APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION KNISONs REV OESCRWION CATS I NWROVEO A REVISEO INSTALLATION DETAILS 06/01/15 1 R.L. B REVISED NAME AND AOORESS 1 10/27/16 IRL NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY 2, PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 1111512016 MI WINDOWS DOORS, LLC 5 F II` 0. MARKETMA GRATZ, PA 17030 VGENS 1P SERIES 185 ALUMINUM FIXEO WINDOW oy6126 73" X 72" NON -IMPACT FINLESS INSTALLATION DETAILS WITH RIGID FILLERS TATE OF omwN• owc No. REV tt`s:CORI Q: G` 08 502E357 B A SCALE aTENTS 09/03/14 6 OF 12 11E\ L. ROBERTO LOMAS P.E. 1432 WOOOFORO RD LEWISVILLE. NC 27023 Luis R. Lomos P.E. FL No.: 62514434.6m-mn t stbmm MMSIONS REV VESCROMON OAIE APPROVIM 2 1/2 MIN. A REVISED INSTALLATION DETAILS 06/01/15 R.L. EDGE DISTANCE B REVISED NAME AND ADDRESS 10/27/16 R.L. CONCRETE/MASONRY BY OTHERS 1 1/4" MIN. 1 1/4" MIN. EMBEDMENT OPTIONAL IX BUCK EMBEDMENTSEENOTES3 — 7 SHEET 1 CONCRETES ASONRY BACKER ROD 1/4" MAX, OTHERS 1/4- MAX. APPROVED SHIM SPACE SHIM SPACE SEALANT OPTIONAL IX BUCK RIGID FILLER SEE NOTES 3 — 7 RIGID FILLERSHEET1 3/16" TAPCON EXTERIOR INTERIOR 3/ 16- TAPCON INTERIOR 3/16" TAPCON BACKER R00 APPROVED RIGID FILLER SEALANT 1/4" MAX 2 1/2" OPTIONAL 1X BUCK SHIM SPACE MIN. SEE NOTE 3 - 7 SHEET I DISTANCE EXTERIOR CONCRETE/MASONRY BACKER ROD BY OTHERS e 1 1/4" MIN. NTOVEO 4. a EMBEDMENT IAMB INSTALLATION DETAIL e • • a CONCRETE/MASONRYINSTALLATION 2 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRET&MASONRY INSTALLATION NOTES: I. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2 PERIMETER AND JOINT SEALANT BYOTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS WITH RIGID FILLERS DRAWN: OWG N0. REv J.L. 08-02357 B sriT NTS °A1E 09/03/14U7 OF 12 L. ROSERTO LOMAS RE 14M W 7ODFORD RD LEYNSVILLE, NC 27023 434488.O 09 ,Oamts®%bnvspe. SIGNED: 1111512016 s R to 0 55 o (TTAATe{'rE O ev Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD h APPROVED SEALANT BEHIND FLANGE 1/2" MIN EDGE DISTANCE 1 1/4' MIN. EMBEDMENT 1/4' MAX. SHIM SPACE 10 WOOD SCREW EXTERIOR INTERIOR 10 WOOD SCREW RIGID FILLER BACKER ROD do APPROVED SEALANT 1/4" MAX BEHIND FLANGE SHIM SPACE WOOD FRAMING 1 I/4' MIN. OR 2X BUCK EMBEDMENT BY OTHERS 1 /2" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4" MIN. 1/4' MAX. EMBEDMENT SHIM SPACE 1/2" MIN EDGE DISTANc INTERIOR 10 WOOD SCREW WOOD FRAMING EXTERIOROR2XBUCK BY OTHERS BACKER ROO k APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE BY OTHERS BACKER ROD k APPROVED SEALANT BEHIND FLANGE r r MIN n ierwurr 1/4' MAX. SHIM SPACE 10 SMS OR ELF DRILLING CREW EXTERIOR INTERIOR 10 SMS OR SELF DRILLING SCREW BACKER R ID do RIGID FILLER APPROVED SEALANT BEHIND FIANCE 1/4• MAX. SHIM SPACE METAL STRUCTURE BY OTHERS 3/4" MIN i EDGE DISTANCE T— VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION 1/4' MAX. SHIM SPACE 3/4' MIN. INTERIOR EDGE DISTANCE 110 SMS OR SELF DRILLING SCREWS METAL EXTERIOR STRUCTURE BACKER ROO doBYOTHERSAPPROVEDSEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION RV OESCRWIM DATE I APPRMO A REVISED INSTALLATION OEfAILS 06/01/15 R.L. B REVISEO NAME AND ADDRESS 10/27/16 R.L. NOTES' I INTERIOR AND EXTERIOR FINISHES. BY OTHERS. NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 1111512016 MI WIND DOORS, LLC 1R II 10 9'', oWw. MnOK ST.\\, \5 GRATZ, PA 17030 v,•GENSF ,J' SERIES 185 ALUMINUM FIXED WINDOW oy8/25 * 73" X 72" NON —IMPACT FILLERS a+607` 4•• TATEFLANGEINSTALLATIONDETAILSWITHOUT OF ; Q,: DRAW ow No. REv i/OF3; F(ORlQP Gt ` J. L. 08 57 B aiE s02NITS09/03/14 8 OF 12 L ROGEWOLOMASAE. 1432 W000FORD RO LEWISVXLE, NC 27M Luis R. Lomas P.E. FL No.: 62514 434-666.0609 A wnas@trlmvspe cam REVISWIS • • REV DESCRPTION WTE APPROVED 2 1/2" MIN. A REVISED INSTALLATION DETAILS 06/01/15 R.L. EDGE DISTANCE B REVISED NAME AND ADDRESS 10/27/16 R.L. CONCRETE/MASONRY BY OTHERS e 1 1/4' MIN. a 1 1/4" MIN. EMBEDMENT OPTIONAL 1X BUCK EMBEDMENT SEE NOTES 3 - 7 SHEET 1 v CONCRETE/MASONRY BACKER R00 & 1 4 MAX. HERS 1/4" MAX. APPROVED SEALANT SHIM SPACE SHIM SPACE BEHIND FLANGE OPTIONAL IX BUCK SEE NOTES 3 - 7 SHEET 1 3/ 16" TAPCON v EXTERIOR INTERIOR 3/ 16" TAPCON INTERIOR 3/16" TAPCON BACKER ROD & APPROVED SEALANT BEHIND FLANGE 1/4' MAX. 2 1/2" OPTIONAL 1X BUCK SHIM SPACE MIN. vSEENOTE3 - 7 EDGE SHEET 1 DISTANCE EXTERIOR BACKER ROD & CONCRETE/MASONRY BY OTHERS 1 1/4" MIN. APPROVED SEALANT a EMBEDMENT BEHIND FIANCE JAMB INSTALLATION DETAIL e CONCRETEAWASONRYINSTALLATION e 2 1/2" MIN, EDGE DISTANCE VERTICAL CROSS SECTION CONCRETE/MASONRY INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES. BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BYOTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 1111512016 MI WINDOWS ANDDDOORS, LLC I tll1`I,i/, oW. wET ST.\\\\\\S GRATZ. PA 17030 w•GENSt•giP' 0 51 SERIES 185 ALUMINUMFIXEDWINDOW73" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS WITHOUT FILLERS QE OF DRAWN: OWo No REv 08`s02 57 B S:c OR1 P ii s/ONA —\\ LUIs R. Lomas P.E. FL No.: 62514 souE a1E NTS 09/03/14 9 OF 12 L. ROBERTO LOADS PE 14M WVOOFORD RO LEM7SVIELE. NC 2702J AJrit8.0609 rpxmas® NP'ssW m WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD k APPROVED SEALANT BEHIND FLANGE 1 /2' MIN. EDGE DISTANCE 1 1/4' MIN. 47 EMBEDMENT 1/4" MAX. SHIM SPACE RIGID FILLER 110 WOOD SCREW METAL STRUCTURE BY OTHERS BACKER ROD k APPROVED SEALANT BEHIND FLANGE 1/4" MAX. SHIM SPACE GID FILLER 10 SMS OR ELF DRILLING CREW REVISIONS • REV OESCRIPTION I DATE I APPROVED IAREVISEDINSTALLATIONDETAILS106/01/15 RL. 8 REVISED NAME AND AODRESS 1 10/27/16 1 R.L. EXTERIOR EXTERIOR INTERIOR INTERIOR 110 SMS OR 10 WOOD SCREW SELF DRILLING SCREW BACKER ROO k RIGID FILLER BACKER ROD do RIGID FILLER APPROVED SEALANT 1/4" MAX. APPROVED SEALANT BEHIND FLANGE SHIM SPACE BEHIND FLANGE 1/4• MAX. ir SHIM SPACE NOTES WOOD FRAMING METAL 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, OR 2% BUCK 1 1 4 MIN. STRUCTURE NOT SHOWN FOR CLARITY. BY OTHERS 7 EMBEDMENT BY OTHERS 2. PERIMETER AND JOINT SEALANT BY OTHERS TOBE T DESIGNED IN ACCORDANCE MTN ASTM E211217: 3/4" MIN IT 1/2" MIN EDGE DISTANCE EDGE DISTANCE DISTANCE VERTICAL CROSS SECTION VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4" MIN 1/4" MAX. EMBEDMENT SHIM SPACE r RIGID FILLER MIN.R_j / EDGE DISTANC 10 WOOD SCREW WOOD FRAMING EXTERIOROR2XBUCK BY OTHERS BACKER ROD k APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION 1/4' MAX. SHIM SPACE RIGID FILLER 3/4" MIN. INTERIOR EDGE DISTANCE i I SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC 11C1o i650W. MARKET ST. R5 4j9 i 10 SMS OR GRATZ. PA 17030 v •'\GENS. •J SERIES 185 ALUMINUM FIXED WINDOWSELFGRILLING 10 6rO'F SCREWS 73" X 72" NON —IMPACT f(/i,A(rl y0a` METAL EXTERIOR FLANGE INSTALLATION DETAILS WITH RIGID FILLERS 70 , TAT STRUCTURE, i0'• ( PORAvntORONO. 08—02357 REV aBY' OTHERS BACKER ROD k 0 SEAT i`S • ORIO . G\ ` BEHIND srALE DAreNTS 09/03/14 10 OF 12 JAMB INSTALLATION DETAIL Luis R. Lomas P.E. L ROBERTO LOMAS P.E. METAL STRUCTURE INSTALLATION 1432 WOOOFORO RD LEWISVILLE, NC 27o27 FL No.: 62514434,w,wy dbMS 1b "Mmm CONCRETE/MASONRY BY OTHERS OPTIONAL 1 X BUCK SEE NOTES 3 — 7 SHEET 1 BACKER ROD do APPROVED SEALANT BEHIND FLANGE EXTERIOR BACKER ROD do - APPROVED SEALANT BEHIND FLANGE OPTIONAL IX BUCK - SEE NOTE 3 - 7 SHEET 1 CONCRETE/MASONRY - BY OTHERS 2 1/2' MIN. EDGE DISTANCE 1 1/4- MIN a 1 1/4- MIN. EMBEDMENT EMBEDMENT CONCRETE/MASONRYlk1/4_ MAX, BY OTHERS SHIM SPACE OPTIONAL 1 X BUCK RIGID FILLER SEE NOTES 3 - 7 SHEET 1 REVISIONS REV DESCRVIION WE APPROVED A REVISED INSTALLATION DEwL5 06/01/15 R.L. B REVISED NAME AND ADDRESS 10/27/16 1 R L. 1/4* MAX. SHIM SPACE r RIGID FILLER 3/ t 6 TAPCON a INTERIOR 3/16" TAPCON INTERIOR 3/16" TAPCON RIGID FILLER 1/4- MAX. SHIM SPACE 1 1/4' MIN. a EMBEDMENT 2 1/2- MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETEVASONRY INSTALLATION 2 1/2- MIN. a EDGE DISTANCE EXTERIOR 1_ 7- BACKER ROD & APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL CONCRETEIWSONRY INSTALLATION NOTES., 1. INTERIOR AN, D EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON -IMPACT FLANGE INSTALLATION DETAILS WITH RIGID FILLERS DRAWN: 01VC NO Re J.L. I 08-02357 B ZZE NTS I O°E 09/03/14 1 "U 11 OF 12 L. Rmnro EOMAS P.E. IAT2 WOODFORD RO LEN7SVR.LE NC 27023 I3I.00<4wq Abws@&bmasmcnm SIGNED: 1111512016 J\ 1fl1111io/ i ter, •G E N fSr' 9iP TAT OF*iLce, Luis R. Lomas P.E. FL No.: 62514 REVISIONS REV OESCRIPTOM 0.1E APPROVED A REVISED INSTALLATION OEfAILS 06/01/15 R.L. APPROVED B REVISED NAME AND ADDRESS 10/27/16 R L. SEALANT BEHIND FIN 1 1/4' MIN. EMBEDMENT 6 WOOD WOOD SCREW FRAMING BY OTHERS 1/4* MAX. SHIM SPACE WOOD FRAMING—I 1/4" MAX 3/8. MIN OTHERS SHIM SPACE EDGE DISTANCE S6 WOOD INTERIORSCREW INTERIOR EXTERIOR 1 1/4- MIN. EMBEDMENT NOTES: 1/4- MAX 1. INTERIOR AND EMRIOR FINISHES, BY OTHERS. r SHIM SPACE APPROVED NOT SHOWN FOR CLARITY. 1 SEALANT 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE 1 BEHIND FIN EXTERIOR DESIGNED INACCORDANCEWITHASTME2112 3/8" MIN 3/B. MIN EDGE DISTANCE EDGE DISTANCE JAMB INSTALLATION DETAIL 6 WOOD SCREW W000 FRAMING WOOD FRAMING OR 2X BUCK INSTALLATION APPROVED 1 1/4" MIN • BY OTHERS SEALANT EMBEDMENT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ. PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FIN INSTALLATION DETAILS oRAmr 0R0 MD. r 08-02357 TS our 09/03/14 SKU12 OF 12 L. RMERTO LOM1S P.E. IAT2 WOODFORD ROLEWISVR.LE. NC 27023 tlI.M&QW9 dbmas@*bwsWOpm SIGNED: 1111512016 RE NS?19 A TAT OF luz 0NA 1E 1\ Luis R. Lomas P.E. FL No.: 62514 Florida Building Code Online Page 1 of 3 db BCIS Home Lop In User RegistrationHot Topics Submit Surcharge Stats 6 Facts ; PublicationsFBC Stall I SCIS Site Map Links Searchb pr Product Approval g a USER: Public User tiv ' Product Approval Menu > ProduR or Application Search > Application List > Application Detall 1 _ FL # FL15353-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived D Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Luis R Lomas, PE the Evaluation Report Florida License PE-62514 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Steven M. Urich, PE f7 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Fl IS353 R3 COI FLCOI.Ddf Standard AAMA 450 Method 1 Option D Year 2010 1 4+..n•//.•nlnir flnrirlol•nilrlinrt nrn/nr/nr or.n rail ocvNv77-i,Aram=,%xr(TFVX(hxrtT)ntT-TR577nvriWTR 12/1 /701 R Florida Building Code Online Page 2 of 3 Date submitted 10/16/2017 Date Validated 10/23/2017 Date Pending FBC Approval 10/26/2017 Date Approved 12/12/2017 summary of Products FL # Model, Number or Name Description 15353.1 5764 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01448B.odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512072B.odf span: 104-1/4". Created by Independent Third Party: Yes 15353.2 5764 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01439B.odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512063B.Ddf span: 83" Created by Independent Third Party: Yes 15353.3 S765 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL35353 R3 II 08-01449B.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512073B.Ddf span: 156-3/8" Created by Independent Third Party: Yes 15353.4 5765 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL35353 R3 II 08-01440B.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 5120646.odf span: 83". Created by Independent Third Party: Yes 15353.5 CM-18514 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 11 08-01442B.odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512066B.Ddf length - 83". Created by Independent Third Party: Yes 15353.6 CM-18520 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01451B.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pcessur-e: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL15353 R3 AE 51207513.1)df span - 156-3/8" Created by Independent Third Party: Yes 15353.7 CM-18523 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 11 08-01452B.odf Approved for use outside HVHZ: Yes:- Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL15353 R3 AE 512076B.Ddf span - 104-1/4". Created by Independent Third Party: Yes 15353.8 CM-18531 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 11 08-01443B.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtH85 72gvdWlS... 2/ 1 /2018 Florida Building Code Online Page 3 of 3 Impact Resistant. Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512067B.Ddf span - 83" Created by Independent Third Party: Yes 15353.9 CM-18532 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS353 R3 11 08-01453B.odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FLIS353 R3 AE 512077B.odf span - 156-3/8" Created by Independent Third Party: Yes 15353.10 CM-18533 Vertical Aluminum Mullion Limits of Use Installation Instructions. Approved for use in HVHZ:-No FLIS353 R3 II 08-01444B.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FLIS353 R3 AE 512068B.odf span: 83" Created by Independent Third Party: Yes 153S3.11 CM-18534 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS353 R3 II 08-01454B.odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FLIS353 R3 AE 512078B.Ddf span: 156-3/8". Created by Independent Third Party: Yes Back Next Contact Us :: 2601 &air Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007.2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this enilty. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please Click h&M. Product Approval Accepts: OEM E Cr6& Ccrd. Safe, https://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWI S... 2/1 /2018 NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) 3) 4) 5) 6) 7) 8) 9) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO MULPON. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI WINDOWS AND DOORS. INC. DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW OR DOOR UNIT. UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. MULLION VERTICAL INSTALLATION IS SHOWN. MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED ANQ MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT. DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EOUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH - W1 + W2 2 REVISIONS REV DESCRIPTION DATE I APPROVED A REVISED INSTALLATION DETAILS 06/10/15 1 R L. B REVISED ANCHORING NOTES @ INSTL OET. 1 06/07/17 IRL ANCHORING NOTES: 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 2) FOR ANCHORING INTO CONCRETE USE 1/4' ELCO ULTRCON TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT WITH 1' MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 3) FOR ANCHORING INTO METAL USE # 10 SMS OR SELF DRILLING SCREW WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 4) ALL FASTENERS TO BE CORROSION RESISTANT. 5) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW. A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3.200 PSI. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). D METAL STRUCTURE -STEEL 18GA (.048') FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .062" THICK MINIMUM. 6) FOR ATTACHING WINDOW UNITS TO MULLION USE 110 SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS 6' FROM EACH MULLION END AND 12" MAX O.C. THEREAFTER. STAGGER SCREWS AT EACH WINDOW TABLE OF CONTENTS SHEET NO. DESCRIPTION 1 NOTES 2 CONFIGURATIONS AND DP CHART 3 INSTALLATION DETAILS 4 COMPONENTS MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 - VERTICAL MULLION 83" MULLION SPAN GENERAL NOTES DRAWN: OWC ISO V.L. 1 08-01439 SMC NTS DATE 01/I1/12 1-E- 1 OF 4 L. ROBERTO LOADS AE 14M WOODFORD RD LEWISVILLE. AIC 27023 434-M-009 fD0nW$@*AW RSpe.cam SIGNED: 1011312017 J\ 9 R I I , x r,•-\GENS- - & fit: sl4o 5 . *' bT/,AtT1rE OF ; LLO'. REV '°F•'c(OROt• \\ e S/OIVA L1 aG\`\ Luis R. Lomas P.E. FL No.: 62514 107 3/8' COMBINED WIDTH W, -{ W2 - B3' 1 1 FRAME HEIGHT WINDOW WINDOW MULLION SPAN) I FW_ 107 3/11' COMBINED WIDTH 1 -jr- W2 107 3/8' COMBINED WIDTH w, --{ w2 83' 1 FRAME 'WINDOW HEIGHT WINDOW MULLION SPAN) 1 1 BY 1 1 WINDOW J WINDO FRAME HEIGHT WINDO MULLION SPAN) 1 1 1 W1 W2 107 3/8' COMBINED WIDTH Design pressure rating (psi) Mullion an In Tributary width (in) 18.13 2550 36.00 42.00 48.00 52.13 25.00 1200 1200 1200 1200 120.0 120.0 37.38 1200 1200 120.0 120.0 120.0 120.0 49.63 120.0 98.3 81.2 76.9 75.2 75.1 62.00 71.0 52.2 39.7 359 33.4 32.3 65.63 59.6 437 330 296 27.4 26.3 72.00 44.9 32.7 24.4 21.8 19.0 19.0 61.D0 28.1 20.3 LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT INCLUDE FLANGE. 107 3/8' COMBINED WIDTH W1 -I[- W2 B3'LwFRAME 1.0. HEIGHT MULLION SPAN) 1 rW1107 3/8' COMBINED WIDTH W2 83' J WINDOI WINDOW J FRAME / / /// HEIGHT !JWINDO MULLION SPAN) IL 1 1 W, i-- W2 107 3/8' COMBINED WIDTH REMSIONs I REV I DEscRrv110N I CATE I APPROVED 6 A REVISED INSTALLATION DETAILS 06/10/15 R.L. B REVISED ANCHORING NOTES & INSTL DET. 06/07/17 R.L. 107 3/11' COMBINED WIDTH IT F_ 1 W2 83" W J I WINDOW J FRAME HEIGHT WINDOW MULLION SPAN') 1 J 1 W, I F - W2 107 3/8- COMBINED WIDTH APPROVED CONFIGURATIONS MULTIPLE UNITS MAYBE MULLED TOGETHER AS LONG AS COMBINED WIDTH DOES NOT EXCEED 107 348' AS SHOWN HEREIN Des i npressure ratiog (pso with rebar Mullion span (in) butary width In 10.13 25.50 36.00 42.00 48.00 52.12 25.00 120.0 120.0 120.0 120.0 1200 120.0 37.38 1200 120.0 120.0 120.0 120.0 120.0 49.63 120.0 98.3 81.2 76.9 76.2 75.1 62.00 95.2 70.0 53.3 48.1 44.8 43.4 65.63 80.0 586 44.2 39.7 36.7 35.3 72.00 1 60.3 439 328 29.2 26.7 255 64.00 1 37.7 27.3 20.1 17.7 160 151 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 - VERTICAL MULLION 83" MULLION SPAN APPROVED CONFIGURATIONS AND RATING CHARTS LARGEAND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 V.L. DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT SCALE INCLUDE FLANGE. 08-01439 NTS DATE 01 / 1 1 / 12 ISHEE72 OF 4 L ROBERTO LOMAS PE. 1432 WOODFORD RD LEWLSOLLE. NC 27023 434.6660609 /Awnsst361wnusp4 Dom SIGNED: 1011312017 vJ\S CEIVS 9 i k• 0 5•• 0:< E iO OF':cZOR10r• -Z Luis R. Lomas P.E. FL No.: 62514 i 1" MIN EDGE DISTANCE MASONRY/CONCRETE BY OTHERS 1 1/4" MIN. EMBEDMENT 1/4" ELCO ULTRACON TAPCON SECT5796 CLIP OPTIONAL RESAR SECT5764 MULLION MT000022 CLIP 10 WOOD SCREW 18 MIN. EMBEDMENT WOOD FRAMING/ 1/2' MIN 2X BUCK EDGE L BY OTHERS DISTANCE VERTICAL CROSS SECTION MASONRYA;ONCRETE AND WOOD FRAMING INSTALLATION NOTE, CLIPS MAY BE USED IN MASONRY/CONCRETE OR WOOD FRAMING SUBSTRATE RCV1510N5 OESCawNON W.rE APPawEp REVISED INSTALLATION DETAILS 06/10/15 R.L. REVI5EO ANCHORING NOTES & INSTL OET 06/07/17 RL. MT000022 CLIP r 10 SMS OR i 1 SELF DRILLING SCREW METAL 1/2" MIN. STRUCTURE EDGE L BY OTHERS DISTANCE VERTICAL CROSS SECTION METAL INSTALLATION SIGNED: 1011312017 MI WINDOW650 WEST MA D ET STREET lLC GRATZ. PA 17030-0370 II`/ o v •\CENS- fdIi O 55764 — VERTICAL MULLION 83. MULLION SPAN INSTALLATION DETAILS a 7'" (, — g1 STATE OF ` O". Pi.e S :` S ONA j1\\\ CRAwN. oa0 N0 OS-011439 aLv B svLc areNTS 01/11/12 3 OF 4 L ROGERrO LOMAS P.E. 1432%'"FORD RD LEWISVILLE NC 27023 uu4-M460s10ams@61msvrcomLuis R. Lomas P.E. FL NO.: 62514 2.140" —I 1.125' SECT5764 MULLION ALUMINUM 6005•T5.115' THICK 0.688- 1.531" RF-14 ?EBAR 16 GA (062) GALVANIZED STEEL NOTES: 1. CLIPS MAY BE USED IN MASONRY/CONCRETE OR WOOD FRAMING SUBSTRATE 2, FOR WOOD & METAL INSTALLATION USE ALL FOUR ANCHOR LOCATIONS. 3. FOR CONCRETE INSTALLATION USE 2 ANCHOR LOCATIONS ONLY WITH 3 1/4" SEPARATION BETWEEN ANCHORS, 3 261' — 1.375" 0.625" H [ L 3.250' 0 843" 1 4.000' O MT000022 CLIP 160A (.0631 GALVANIZED STEEL SEE NOTE 2 6 3, THIS SHEET. 3.750' 2.i89" 1.0 0" D( 0.375" L— 0.843" 2x 00.210" I 1.562" r 1.562" LO SECT5796 CLIP FOR WOOD FRAMING INSTALLATION ALUMINUM 6063•T5.125• THICK 3.750' 1.000" 0.843- RLNSKINS OESCRIPMM OArE I IPPWIEO REVISED INSTALLATION DETAILS 06/10/15 R.L. REVISED ANCHORING NOTES & INSTL DET 06/07/17 R L. 2.675' SECT5796 CLIP \- 2x 00.210" FOR CONCRETE INSTALLATION ALUMINUM 6063.T5.125-THICK MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ. PA 17030-0370 5764 — VERTICAL MULLION 83" MULLION SPAN COMPONENTS DRAWN 7N0. V.L. 08-01439 suuE NTS I oAM 01/11/12 s'W4 OF 4 L ROSERTO LOMAS PE. 1432 WOODFORD RD LEH7SVXLE. NC 27023 434.66E-0609 .Oom+s Wia aaW odn SIGNED: 10/1"017 5111 1 I I I/ j//// i 1.011 5pp * O FS.. i/7/s'ONA j1\ \ Luis R. Lomas P.E. FL No.: 62514 Florida Building Code Online Page 1 of 3 SCIS Home l Log In I User Registration j Hot Topics I SubmR Surcharge l Stats & Facts ; Publications FSC Staff ' BCIS site Map Links search Florid a 11 wd: Product ApprovalrUSER: Public User 91-11IM". =-R Product Approval Menu > Product or Application Search > &QpJ%Atlpn LKt > Application Detail FL # FL13223-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived D Product Manufacturer James Hardie Building Products, Inc. Address/Phone/Email 26300 La Alameda Ste. 250 Mission Viejo, CA 92691 909)349-2927 pingsheng.zhu@jameshardie.com Authorized Signature Pingsheng Zhu pingsheng.zhu@jameshardie.com Technical Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana, CA 92337 909) 349-2927 pingsheng.zhu@jameshardie.com Quality Assurance Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana, CA 92337 909) 349-2927 pingsheng.zhu@jameshardie.com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Ronald 1. Ogawa the Evaluation Report Florida License PE-24121 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12131/2020 Validated By John Southard, P.E. G Validation Checklist - Hardcopy Received Certificate of Independence FL13223 R4 COI RIO - Certificate of Independence.odf Referenced Standard and Year (of Standard) Standard ASTM C1166 ASTM E330 Year 2007 2002 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL13223 R4 Eaulv RI0-2692B-17 ASTM C1186 eouivalencv.Ddf http://www. floridabuil ding.org/car/pr_app_dtl.aspx?param=wGEVXQwtDgvRk6bsvZ66FC... 2/6/2018 Florida Building Code Online Page 2 of 3 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/09/2017 08/25/2017 08/28/2017 10/10/2017 FL # Model, Number or Name Description 13223.1 Cempanel Siding fiber -cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13223 R4 II cemoanel-installation.Ddf Approved for use outside HVHZ: Yes F1_13223 R4 11 NOA 17-0406.06.odf Impact Resistant: Yes FL13223 R4 11 RIO 2689-17 Panel to Furrino.Ddf Design Pressure: N/A FL13223 R4 11 RIO-2686-17 Panel Wood Metal Frame.Ddf Verified By: Ronald 1. Ogawa 24121Other: For use inside a HVHZ install in accordance with NOA 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06,Ddf FL13223 R4 AE RIO 2689-17 Panel to Furring.Ddf FL13223 R4 AE Rio-2686-17 Panel Wood Metal Frame.odf Created by Independent Third Party: Yes 13223.2 HardiePanel Siding fiber -cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13223 R4 II HardiePanel-Installation.Ddf Approved for use outside HVHZ: Yes FL13223 R4 11 NOA 17-0406.06.odf Impact Resistant: Yes FL13223 R4 11 RIO 2689-17 Panel to Furrino.Ddf Design Pressure: N/A FL13223 R4 11 RIO-2686-17 Panel Wood Metal Frame.Ddf Verified By: Ronald I. Ogawa 24121Other: For use inside a HVHZ install in accordance with NOA 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06.Ddf FL13223 R4 AE RIO 2689-17 Panel to Furring.Ddf FL13223 R4 AE RIO-2686-17 Panel Wood Metal Frame.Ddf Created by Independent Third Party: Yes 13223.3 Prevail Panel Siding fiber -cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13223 R4 Il NOA 17-0406.06.Ddf Approved for use outside HVHZ: Yes FL13223 R4 11 Prevail- Panel- Installation, Ddf Impact Resistant: N/A FL13223 R4 Il RIO 2689-17 Panel to Furrina.Ddf Design Pressure. N/A FL13223 R4 II RIO-2686-17 Panel Wood Metal Frame.Ddf Venfied By: Ronald I. Ogawa 24121Other: For use inside a HVHZ install in accordance with NOA 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06.Ddf FL13223 R4 AE RIO 2689-17 Panel to Furrino.Ddf FL13223 R4 AE RIO-2686-17 Panel Wood Metal Frame.odf Created by Independent Third Party: Yes Badr next Contact Us :: 2601 &air Stone Road, Tallahassee FL 323" Phone: 850-487-1924 The State of Florida Is an AA/EEO employer. Copyright 2007.2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida low, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address It they have one. The emalis provided may be used for Official communication with the licensee. However email addresses are public record. If you d0 not wish to supply a personal address, please provide the Department with an email address which on be made available to the public. To determine of you are a licensee under Chapter 455, F.S., please pick here. Product Appr ovaal Accepts: E http://www.floridabuilding.org/car/pr_app_dtl. aspx?param=wGEVXQwtDgvRk6bsvZ66FC... 2/6/2018 Florida Building Code Online Page 3 of 3 Credh Card Safe http://www. flori dabuilding. org/pr/pr_app_dtl.aspx?param=w,GEVX QwtDgvRk6bsvZ66FC... 2/6/2018 Florida Product Approval HardiePanel® Siding For use inside HVHZ: o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami -Dade County Florida NOA 17- 0406.06. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. For use outside of HVHZ, o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Reports RIO-2686-17 or RIO-2689-17. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. a Hardie Pane I'IZZIM. JamesHardie Vertical Siding INSTALLATION REOUIREMENTS RESIDENTIAL SINGLE FAMILY ONLY - PRIMED & COLORPLUS° PRODUCTS EFFECTIVE SEPTEMBER 2013 Visit :vww.rameshardie.com for the most recent version. SMOOTH CEDARMILL® - SELECT SIERRA 8 - STUCCO IMPORTANT. FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY, BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS. INSTALLATION OF HZ1 OTm PRODUCTS OUTSIDE AN HZ1011 LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONE APPLIES TO YOUR LOCATION, VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343 STORAGE & HANDLING: Store flat and keep dry and covered prior to installation. Installing siding wet or saturated may result in shrinkage at butt joints. Carry planks on edge. Protect edges and corners from breakage. James Hardie is not responsible for damage caused by improper storage and handling of the product. CUTTING IN OLrrDOORS INDOORS 1. Position arcing station so that wind vAll blow dust away from user 1. Cut only using score and snap, or shears (manual, electric or pneumatic). and others in waking area 2. Position cutting station in wall -ventilated area 2. Use one of the following met hods: a. Best i. Score and snap - NEVER use a power saw indoorsi. Shears (manual, efetbrlC a pneumaGr.) b. Better. i. Dust reducing circular saw equipped with a - NEVER use a circular saw blade that does not carry the HardeBlade saw blade trademark HardteBWde° saw blade and HERA vacuum extraction NEVER dry sweep — Use wet suppression or HEPA Vacuum c. Good: I. Dust reducing circular saw with a IiardieBbde saw blade ony use for low to moderate cutting) linportant Note: For mandnwm protection pAiest respirable dust producttm), James Hardie recommends aNrdyS using "Best' -level witing methods whae feasible. NIOSH-approved respirators can be used canjunctim vA above arcing practices to furdter reduce dust a ipostnes. Additional evosure indormabon is available at m-m.jamesharche.com to help you determine the most appropriate cutting method for your job requirements ti concem still eases abort exposure levels or you do not comply with the above practices, you should always txnsrff a qualified i clustrhal hygienist or contact James Hardie for further Information. stnentrc, GENERAL REQUIREMENTS: These instructions to be used for residential single family installations only. For Commercial / Muhl -Family installation requirements go to www.JamesHardteCommercial.Com HardiePaneP vertical siding can be Installed over braced wood or steel studs spaced a maximum of 24" o.c. See genemal fastening requirements. Irregularities in framing and sheathing can mirror through the finished application. James Hardie recommends installing HardiePanel on a capillary break (ralnscreel*rring) as a best practice. Information on installing James Hardie products over foam can be located in JH Tech Bulletin 19 at www. Onnehardie.com A water -resistive barrier is required in accordance with local building code requirements. The water -resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water Infiltration. Jarnes Hardie does manufacture HardieWrapO Weather Barrier, a non -woven non -perforated housewrapl , which complies with building code requirements. When installing James Hardie products all clearance details in figs. 5,6,7,8,9,1 OW 1 must be followed. Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minimum of 6" in the first 10'. Do not install James Hardie products, such that they may remain in contact with standing water. HardiePanel vertical siding may be Installed on vertical wall applications only. DO NOT use HardiePanel vertical siding in Fascia or Trim appplications. Some application are not suitable for ColorPlus. Refer to ColorPlus section page 3. DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie4° Products. For larger projects, including commercial and mufti -family projects, where the span of the wall is significant in length, the designer and/or architect should take into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be found in the Technical Bulletin 8 "Expansion Characteristics" at wwww.JamesHardie.com. INSTALLATION: Joint Treatment Fastener Requirements • Vertical Joints - Install panels in moderate contact (fig. 1), alternativelyPositionfasteners3/8" from panel edges and no closer than joints may also be covered with battens, PVC or metal jointers or2" away from corners. Do not nail into corners. caulked (Not applicable to ColorPlus• Finish) (fig. 2). HardiePanel Vertical Siding Installation • Horizontal Joints - Provide Z-flashing at all horizontal joints (fig. 3). Framing must be provided at horizontal and vertical edges for nailing. Figure 2 Figure 3HardiePanelverticalsidingmustbejoinedonstud. water -resistive barrier water -resistive barrier Double stud may be required to maintain minimum edge 4 stud water-reslstwe water•resistrve nailing distances. - x 4 send barrier barrier Figurer stud .— upper panel ._upper panel water resistive Do not 1/4" gap Do not 1/4" gap barrier Caulk Caulk sheathing HardiePanel Batten Joint "H" Joint r'p".ne 8ashrno t ''Z•Ilashmg t 0 o vertical siding water -resistive barrier decorative 2 x 4 stud"— band board keep nails wer3/ m men. l `lower from panel panel edges plate o Figure 4 fie, 'Tleave appropriate gap between Recommendation: When o panels, then caulk* installing Sierra 8, provide ra Caulk Joint a trouble stud at panel modeto contact Ma applicable 10 ColaPlus• Finish) joints to avoid parting keep fasteners 2' Apply caulk in accordance with caulk through grooves. away from comers manufacturer's written application instructions. r For additional information on HardieWraVm Weather Barrier, consult .lames Hardie at 1-866-4Hardie or www.hardiewrap.com WARNING: AVOID BREATHING SILICA DUST James Hardie° aoduds conwn resalable Crystalline silica, which Is known ;o the State of California to cause canter and is consioared by IARC and NIOSH to be a cause of cancer from some occupetronal sources. &eaating excessive amourds 01 resfxrade saner dus an also cruse a disabling afro p0lemWtiy later lung disease celled sdIt0515, arid has teen linked wkh other diseases. Some stutlfes suggest smoking may Increase these risks.During installation or handling. (1) wok in outdoor areas wcJh amde ventilation; (2) use fiber cement shears for doting or, whale not feasible, use a Haroaade• saw blade and dust -reducing circular saw anadred 10 a HEPA vacuum: 0 warn others in the immediate area, (4) wear a proDerfy-lmeo, NIOSH-aDDroved dust mask or respirator (e.p N-95) in accordance with apoliable govainment regulations and mamdaciurer rnstrumon5 to further umrt resorrable sera exposures. During clean-uD, use HEPA vacuums or wet cleanup methods - new dry sweep. For fumes information, refer to our installation instructions and Material Safety Data Sheet available at www.)amesnarde. corn or by alhng 1-eoo-SHARD: (1-800.942.7343). rAlU6iE TO ADHERE TO WR WARNINGS, MSDS, AND INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH CMA HS1236 - P1/ 3 1/13 N >o. CLEARANCES Install siding and trim products in Maintain a minimum 1 " Maintain a minimum 1 " 2" clearance At the juncture of the roof and vertical Maintain a 1 /4" compliance with local building code 2" clearance between between James Hardie products decking material. surfaces, flashing and counterflashing shall be installed per the roofing clearance between the bottom of James requirements for clearance between James Hardie*` manufacturer's instructions. Provide a Hardie products and the bottom edge of the siding and products and paths, Figure 7 minimum 1 % 2" clearance between horizontal flashing. the adfacertt finished grade. steps and driveways. the roofing and the bottom edge of the Do not caulk gap. d siding Ififirlt, ater siding and trim. Refer to fig. 3 on Figure 5 _ Sl sldtna fYlf Figure 6 mer Figure 8 iLll it-rmin. page 1. t i rP r t nl n concretefoundation Maintain a minimum 1" gap between gutter end caps and siding & trim. Figure 9 siding gutter and end cap 1 r12min r t deck material Do not bridge floors with HardiePanel® siding. Horizontal joints should always be created between floors ffig.10). water. Resistive Berner Framing Figure 10 Horizomal Fbonng Trim Sheathng fascia ' VI-18rdiePartel" BLOCKED PENETRATIONS Penetrations such as hose bibs and holes 1 w or larger such as dryer vents should have a block of trim around point of penetration. GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot - dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie products near the ocean, large bodies of water, or in very humid climates. Consult applicable product evaluation or listing for correct fastener type and placement to achieve specific design wind loads. NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable compliance documentation. Drive fasteners perpendicular to siding and framing. Fastener heads should fit snug against siding (no air space). (fig. A) Do not over -drive nail heads or drive nails at an angle. If nail is countersunk, fill nail hole and add a nail. (fig. B) For wood framing, under driven nails should be hit flush to the plank with a hammer (for steel framing, remove and replace nail). NOTE: Whenever a structural member is present, HardiePlank should be fastened with even spacing to the structural member. The tables allowing direct to OSB orplywood should only be used when traditional framing is not available. Do not use aluminum fasteners, staples, or clipped head nails. Snug Flush 9711 Countersunk fill & add nail Figure A Figure B do not under drive nails Do NOT STAPLEKICKOUT FLASHING Because of the volume of water that can pour down a sloped roof, one of the most critical flashing details occurs where a roof intersects a sidewall. The roof must be flashed with step flashing. Where the roof terminates, install a kickout to deflect water away from the siding. lf is best to install a self -adhering membrane on the wall before the subfascia and trim boards are nailed in place, and then come back to install the kickout. Figure 11, Kickout Flashing To prevent water from dumping behind the siding and the end of the roof intersection, install a "kickout" as required by IRC code R905. 2.8.3 :'...flashing shall be a min. of 4" high and 4' wide." James Hardie recommends the kickout be angled between 1000 -110e to maximize water deflection Figure 11 PNEUMATIC FASTENING James Hardie products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachment on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive under driven nails snug with a smooth faced hammer - Does not apply for installation to steel framing). HS1236 • P2/3 8113 y >v, CAULKING For best results use an Elastomsric Joint Sealant complying with ASTM C920 Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTM C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note: OSI Quad as well as some other caulking manufacturers do not allow tooling. DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section CUT EDGE TREATMENT PAINTING Caulk, paint or prime all field cut edges. DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie6 Products. James Hardie products James Hardie touch-up kits are required must be painted within 180 days for primed product and 90 days for unprimed.100% acrylic topcoats are to touch-up ColorPlus products. recommended. Do not paint when wet. For application rates refer to paint manufacturers specifications. Back -rolling is recommended if the siding is sprayed. COLORPLUS° TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE Care should be taken when handling and cutting James Hardie® ColorPlus® products. During installation use a wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product, then rinse with a garden hose. Touch up nicks, scrapes and nail heads using the ColorPlus® Technology touch-up applicator. Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with new HardiePanel® siding with ColorPlus Technology. Laminate sheet must be removed immediately after installation of each course. Terminate non -factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus° product dealer. Treat all other non -factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer. Note: James Hardie does not warrant the usage of third parry touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up, will not be covered under the James Hardie ColorPlus Limited Finish Warranty. The following outlines the recommended applications for ColorPlus and Primed panels. Not all designs will be suitable for every application: Exposed fasteners or battens is the recommended application for ColorPlus panel products Do not use touch-up over fastener heads for smooth ColorPlus products - primed panel recommended For ColorPlus panel applications that require fasteners in the field, it is acceptable to use touch-up over fasteners for Cedarmill and Stucco panel only, but correct touch-up application is important. Some colors may show touch-up when applied over fasteners. Trim,is recommended to cover joints when appropriate. PAINTING JAMES HARDIE° SIDING AND TRIM PRODUCTS WITH COLORPLUS° TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: Ensure the surface is clean, dry, and free of any dust, dirt, or mildew Repriming is normally not necessary 100% acrylic topcoats are recommended DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie® Products Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature RECOGNITION: In accordance with IMES Evalualon Relion ESR-1844, HardiePane* vertical siding is recognized as a suitable akemate to that specified in. the 20D6.20D9, 8 2012 International Residential (ode la one -and Two-Famly Dwellings and the 2006, 2009.8 2012 International Building Code. HardePanal vertical siding is also recalinLed for apoIication In the foeovnng. City of Los Angeles Research Report No. 24862, State of Flodda listing FLfr889, Dade county, Flonoa NOA No. 02-0729.02, U.S. Dept. of HUD Materials Release 1263c, Texas Department of Insurance Product Evaluation EC-23. city of New York MEA 223.93-M, and California DSA PA-019. These documents should also be consulted for additional inforrnadon concerning the suitability of this product for specAc apolcanons. m 2013 James Hardie Building Products. All rights reserved. TM, SM, and ® denote trademarks or registered trademarks of Additional Installation Information. James HardieTechnology Limited E is a registered Warranties, and Warnings are available at r"N JamesHardie trademark of James Hardie Technology Limited. www.jameshardie.com HS1236 - P3/3 6/13 MtAM MADE COUMY ACCREDM ACCREDITED July 30, 2017 Pingsheng Zhu, P.E. Product Compliance Engineer James Hardie Building Products 10901 Elm Ave. Fontana, CA 92337 Re: NOA-17-0406.06 Relative to FBC 2017 Project RIO-2679AA-17 Dear Pingsheng. After review of the 2017 FBC, it is my opinion that the curreht' NOA-17-0406.06 is in compliance with the 2017 Florida Building Code. Referenced Standards in the-2017 FBC: 1. Wood: AWC NDS-2015 & SDPWS-2015 2. Structural Loads: ASCE/SEI-7-10 3. Concrete: ACE-318-14 4. Masonry: TMS402-2016/AC153ti-13/ASCE-5-13 . 5. Structural Steel: AISC 360-10 (Including manual of steel construdon 2010 (140"edition)) 6. Cold -formed Steel: AISI 100.12 1. Aluminum: ADM-1-2015 In addition, I am making the following Statement of Independence -as requested: 1. Ronald Ogawa. does not have nor does it intend to acquire or will it acquire any financial interest in any company manufacturing or distributing products for which evaluations are issued. 2. Ronald Ogawa is not owned, operated or controlled by.any company manufacturing or distributing products ft'evaluates or inspect. 3. Ronald Ogawa Inc does not have, nor will it'aoquire a financial interest In any company manufacturing or distributing products for which reports are being issued., 4. Ronald Ogawa does not have, nor will it acquire a financial interest in any other entity involved in the approval process of the producL Should you have any questions on anything, please'coritact rile. Sincerely, Ronald 1. Ogawa, P!E. U RI Ogawa & Associates, Inc. IAS Laboratory Approval, TL 360 IAS Quality Control Agency, AA-705 CRRC Approved Testing Laboratory for Solar Reflectance and Emissivity State of Florida Approved Validator and Third Party Quality Control Agency 714) 292-2602 ron&riogawa:com CC: Roger Ogawa — RI Ogawa & Associates, Inc.: Karen Ogawa — RI Ogawa & Associates, Inc. Lab Address: 1985 Sampson Avenue, Corona, CA 92879 • Phone (714) 321-4939 • Fax (714) 908-1815 • E-mail: rooeTerioaawa.com Malling Address: 16835 Algonquin St. it443. Huntington Bead,, CA 92649 • Phone.(702) 491-3710 a Fax (714) 908-1815 • E-mail: debbyOrioaawa.cam Engineering . Quality Control 9 Product Development 9 Inspections 9 Code Consulting • Expert Witness • Testing EMONVEM M IAMI-DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) wv/ w.miamidade.Qov/eOn 0-M-Y James Hardie Building Product, Inc. 10901 Elm Avenue Fontana, CA 92337 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: "Hardie", "Cem" and "Prevail" Planks and Panels Fiber Cement Siding and Soffit APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets I through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I. Ogawa, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo; Plant City, Florida, and the following statements: "ASTM C 1186 Type A compliant" and "Miami -Dade County Product Control Approved" is to be located on each siding plank or panel and per FBC 1710.9.2 and 1710.9.3 on soffit panels. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product - TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words J Cami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 15-0122.04 and: consists of this page 1 and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 17-0406.06 Expiration Date: May 1, 2022 Approval Date: May 4, 2017 y7 /2017 Page I James Hardie Building Products, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS "Submitted under NOA # 13-0311.07" 1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I. Ogawa, P.E. B. TESTS "Submitted under NOA # 13-0311.07" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of HardiePlank, HardieSoffit and HardiePanel, prepared by Intertek Testing Services NA LTD, Test Report No. 100733361COQ-004, dated 08/24/2012, with revision 1 dated 04/25/2013, signed and sealed by Rick Curkeet, P.E. C. so l9 Submitted under NOA # 02-0729.02" Laboratory Report Test Date Signature 2. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves P.E. 3. ATI 16423-2 PA 202 & 203 03/18/96 A. N. Reeves P.E. 4. ATI 16423-3 PA 202 & 203 03/18/96 A. N. Reeves P.E. CALCULATIONS 1. None. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS "Submitted under NOA # 15-0122.04" 1. Statement letter of code conformance to the 5 h edition (2014) FBC issued by Ronald I. Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald I: Ogawa, P.E. 04.r7/70107 Carlos M Utrera, P.E. Product Control Examiner NOA No. 17-0406.06 Expiration Date: May 1, 2022 Approval Date: May 4, 2017 E-1 PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Execration Ate 05/01 /2022 By MIamF-Dade Product MkCI' MVV liviAq *1 h aladimcwk No !! B WALL LENGTH - Stud Spacing at 115' O.C. I Ste* Nails at 16' O.C. (typ.) 318, Mihimum Edge Distance A«_ Sheathing fastener, as described in Note 1 Panel fastener, as described in Note 2 HardiePanel, Cempanel, Prevail Panel Siding Water -resistive barrier per Florida Building Code Section 1404.2 IN, 5/8" thick / 5 ply APA rated plywood sheathing fastened in accordance with Florida Building Code Section 2322.3 2" X 4" S-P-F Wood Studs The wall and soffit frames are m be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. PRQDUC[.E_SCMPTI0 1 SEE 1 IardiWP e_ Cempanel®, & DETAIL A Prevail® Panel Siding materials are nonasbestos fiber -cement products 5/8" thick 16 ply APA rated tested in accordance with ASTM plywood sheathing in C1186 Grade 11, Type A and meeting a=dence with Florida the requirements ofthe Florida Building Code Section Building Code. 23223 M-9 RItN IyS PM Water -resistive Width Length Thickness barrier per Florida q' 8,9,10' 5/16" Building Code Section 1404.2 DESIGN PRES Mag-BATING 2' X 4" S-P-F Installation Design Pressure Wood Studs Wood Studs -76 psf r HardiePanel, Impact Resistant- Planks installed over 5/B" thick / 5 ply Of g.g Cempanel, APA rated plywood sheathingPrevailPanel Siding klgf DlE,I t ]CEMP NEL, PRNAILEANEI.LSID NG INSTA_.LAO I DETA1.4$ All installation shell be done In conformance with this Notice of Acceptance, the manufaoturees installation recommendations, and the applicable sections of the Florida Building Code. Wood studs where HardiePanel, Cempanel, Prevail Panel Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.OA LWOW 1] 50 thick / 5 ply APA rated plywood sheathing shall be attached to the studs In accordance with Florida Building Code Section 2322.3. plywood sheathing supporterThesidingpanelsshallbeinstalledover5/8' thick 15 ply APA rated pl yw by a minimum of 2"X4" S-P.F wood studs spaced a maximum of 16.O.C. Note 2] The siding panel fastener shall be a 2" long, 0.223" head diameter, 0.092" shank diameter, corrosion resistant siding nail; the fasteners shall be spaced at 6" O.C. at p ratratedandintermediatestuds; the fasteners shall be driven through the 5/8" thick / 5 ply APA plywood sheathing into wood studs located at 16" O.C. Fasteners shall have a minimum edge distance of 318" and a minimum clearance of 2" from comers. HARDIEPANEL, CEMPANEL, PREVAIL PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 A I I PNL-PLK--SOFF Creator. E. Gonzales IscuE 1n" =1' 0° Date: 4/24/2013 Isrrr:m 1 OF 12 Fastener Spacing per Florida Cladding Building Code Section 2322.3 16.00in. I . FramingI iStt97NCi tEv1s» ' I • Fastener Spacing per Florida Sheathing o 0"giodg whir Ot•fA°rib Building Code Section 2322.3 BdIffins Coec Aooepww NO 12 I • I Pmdud I I I I ,'rrrrr rtcoDucTlv PRODUCT RENEWED wep}yi widtdrlElor a as complying with the Florida Baalft a-Gt /t,c'7 Building Code trio NOA-No. 17-0406.06 Exptratlon 05/01/2022 .per : STA • By, t Prodoa Contmt Miami- a duct Co tro - tS ' "" J0Noil'' siFiAMING NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE WITH3-11T 16d COMMON NAILS (2 PER TOP AND NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) BOTTOMCONNECTION) THE WALLANd SOFFIT FRAMESARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEA_ T.}lNG NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD HARDIEPANEL, CEMPANEL, PREVAIL PANEL SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA INSTALLATION DETAILS WOOD STUD CONSTRUCTION BUILDNG CODE SECTION 2322.3 • • (S' tApbINGJames Hardie Building Products, Inc. THE PANEL IS FASTENEb WITH 2• LONG, 0.223 HEAD DIAMETER, 0.092'•' SHANK DIAMETER, CORROSION 1° Fontana, a, CA 92337 Avenue RESISTANT SIDING NAILS, PLACE NAILS 6" O.C. AT PANEL EDGES AND INTERMEDIATE STUDS Phone: 909-356-6300 sae Fscu No own No Fax 909-421-0634 A PNL-PLKSOFF Creator. E. Gonzales sou.e 1• =1'-0" Date: 4/24 2013 sr+w 2 OF 12 1 PRO[ as con Bulldir NOA—N Expira By_ Mlaml- WALL. L i WALL LENGTH Stud Spacing at 16" O.C. a l Flat;me rro J/1.v7 3/8" Minimum Edge Distance 0121 '' No, 21 STATE ' 4' "kOR10 I /ONAII Nails at 6" O.C. (typ.) QFLA4.A_ Sheathing fastener, as described in Note 1. BELLhe-FkW& ir\` Panel fastener, as described In Note 2 HardiePanel® Siding r 1 IL Water -resistive barrier perr Florida Building Code Section 1404.2 0 1UCT RENEWED iplying with the Florida 9 Code o. 17-0406.06 5/8" thick / 5 ply APA rated plywood sheathing fastened to metal studs as descibed in Note 1. Ion D e05/01/2022 209a, 3-5/8" X 1 5/8" Metal C-stud The wall and soffit frames are to be designed a e Product Control by the Architect or Engineer of Record In I compliance with the Florida Building Code. SEE DETAIL A 518" thick / 5 ply APA rated plywood sheathing fastened to metal studs as described in Note 1 C--110BJL4 Water-reststive barrier per Florida Building Code Section 1404.2 20ga. 3-5/8" X 1-6/8" Metal C-stud p$Qt CMr;-Mr; HardlePanel®, Cempanel®, & PI'evailO Panel Siding materials are nonasbestos fiber -cement products tested in accordance with ASTM C1186 Grade II, Type A and meeting the requirements of the Florida Building Code. 9KI;4R N9N S 0_N.s. Width Length Thickness 4' 8,9,10- 5/16" QESIG_N 3ESSURE RATJfJ_G_ Installation Design Pressure Metal Studs -104 psf HardlePanel, Impact Resistant — Cempanel, Panel installed over 618" thick / 5 ply Prevail Panel APA rated plywood sheathing Siding tjAFRDIJ=PAiJ LyCEMPg VFsL PgE(AIL PAJ 1F,,_SIDING it_yS-1k- L.LAnoN_D_iumi-S All installation shall be done In eonforman6e with this Notice of Acceptance, the manufacturers installation recommendations, and the applicable sections of the Florida Building Code. Metal studs where HardiePanel, Cempanel, Prevail Panel Siding will be Installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. Note 115/8" thick / 5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc at panel edges and all intermediate supports using a No.6-18, 0.315" head diameter x 1-1/4' long bugle head screw The siding panels shall be installed over 5/8" thick / 5 ply APA rated plywood sheathing supported by a minimum 20ga, Nominal 3-5/8" X 1-5/8" Metal C-studs spaced a ma)dmum of 16" O.C. Note 21 The siding panel fastener shall be a minimum No. 6-18, 0.315" head diameter X 1-5/8" long' ribbed bugle head screw ('or screw shall have at least 3 full threads penetrating metal framing); the fasteners shall be spaced at 6" O.C. at panel edges and Intermediate studs; the fasteners shall be driven through the 5/8" thick / 5 ply APA rated plywood sheathing into metal studs located at 16" O.C. Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from comers. Phone.909-356-6300 SUE Fax 909A27-0634 A Creator. E. Gonzales SCALE HARDIEPANEL, CEMPANEI, PREVAIL PANEL fNSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 PNL-PLKSOFF 11r c 11-0" 1 Date: 4/24I2013 ISHEET 3 OF 12 6.00in. 6.001n. I I I•I I PRODUCT RENEWED • . as complying with the Florida 3ullding Code NOA-No. 17-0406.06 T xplration te05/01/2022 6.00in. y PRODUCTbtEvtsw ea complying with the irlmt b Air» /" 13Ir-T t F piratioovox l '% By Mcmu adcE'rodadt+atrol I II I• I 6.00in. I II• II II I PRCDtyCi REME o c'+ot0il^nf3 aiih the Fbrida orae c i • mite fted d. F_M—KI -G NOMINAL 20 GAUGE 3-5/0 FASTENED WITH 518, WAFER HEAD SCREWS ( 8' STEEL D2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO 8E DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE adJEA- JF )NGNOMINAL 5/8 THICK / 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6" OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A NO.8-18, 0.315' HEAD DIAMETER X 1-1W LONG BUGLE HEAD SCREW CLADDINGTHEPANEL IS FASTENED WITH NO. 8A8, 0.315" HEAD DIAMETER X 1-5/8' LONG CORROSION RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING), PLACE SCREWS 6" O.C. AT PANEL EDGES AND INTERMEDIATE STUDS 6.00in. Cladding Framing II Sheathing II I.1 I I II I•I .I I I I I OGA 4, I I I I ,III y 0. 121 STATE OF ' • I' I I I O FCO R10Q' • • '-i' s/ONA FOR METAL AND WOOD STUDS. PROVISIONS FOR TY LOAD NOT PARTF TDIAPHRAGM H S APPROVAL (MUST PROVIDE ALTERNA ES O PROVISIONS FORESELOADS)RE HARDIEPANEL, CEMPANEL, PREVAIL PANEL INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Ina 10901 Elm Avenue Fontana, CA 92337 Ei1ZE fSGid NO ammo hone: 0. 3 300PNL- PLK- SOFF Fax 94 A Creator: E Gonzales sage Date: 4124/2013 sneer a OF 12 T WALL i WALL LENG SEE Stud Spacing at 16" O.C. l7ETAtL A ds oort$lYio with {qe Floods I fie• . - I Bw"cdit I a-, I,t % =1 r r ! l:xpira{,orr » 7 I s15 1- s 1 Mi ode 1'rodrrtl Coohol 3!4" Minimum Edge Distance Nails at 16" O.C. (typ.) DETAIL A t , .. ,. •'777f i1i5 PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Sheathing fastener, as described in Note 1 Siding fastener, as described in Note 2 HardiePlank, Cemplank, Prevail r Lap Siding Water -resistive barrier per Florida Building Code Section 1404.2. 1 W 5/8" thick 15 ply APA rated plywood sheathing fastened r In accordance with Florida Building Code Section 2322.3 Expiration te05/01/2022 2"X 4' S-P-F Wood Studs The wall and soffit frames are to be designed By by the Architect or Engineer of Record in Miami ii a Product Control compliance with the Florida Building Code. MpQUS vacgalNT N HardiePlank®. Cemplank®, & Prevail® Plank Lap Siding materials 5/8" thick 15 ply APA are nonasbestos fiber -cement rated plywood products tested in accordance with sheathing in ASTM C1186 Grade 11, Type A and accordance with meeting the requirements of the Florida Building Code Florida Building Code. Section 2322.3 PAN E DJD -- _ SIGNS - Water - resistive Wid.dthLength Thickness barrier per Florida 59-112' 12' 5/16" Building Code Section 14042 ' QFSIGN-PRF_SSI.RtyRA:1 NQ 2" X 4" S-P-F Installation Design Pressure Wood Studs Wood Studs -92 psf Lap Siding Impact Resistant - Planks Installed over 5/8" thick / 5 ply 001.114" ialt X 5/16" APA rated plywood sheathing Bthick starter strip FigE201J= P_L 9 KLCEfiIIPLgN(PRE-AL L?A SIDINGJNSYALLA_T OR0 __J . All Installation shall be done in conformance with this Notice of Acceptance, the manufacturer's Installationrecommendations, and the applicable sections of the Florida Building Code. WoodstudswhereHardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an EngineerorArchitectpertheFloridaBuildingCodeandtherequirementsofthisN.O.A. Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall be attached to the studs In accordance with Florida Building Code Section 2322.3. Planksshallbeappliedhorizontallycommencingfrom the bottom course of the wall with 1AW wide laps at the top of the plank such that the exposure area of each plank is:5 6-1/4" vertically. Note21Thesidingfastenershallbea2-1/2' long, 0.223" head diameter, 0.092" shank diameter, oorroslon-resistant siding nail; The siding is fastened S 8-1/4" O.C. vertically and 16" O.C. horizontally: fastenersaredrivenintowoodsWdsthrough518" thick / 5 ply APA rated plywood sheathing, fasteners areplacedIntheoverlappingareaapproximately3Wfromthebottomedgeoftheoverlappingplank. Vertical Joints shall be placed over studs. Theplanksshallbeinstalledover5/8" thick / 5 ply APA rated plywood sheathing supported by a minimum of 2"X4" S-P-F wood studs spaced a maximum of 16" O.C_ Fasteners shall have a minimum edge distance of 3/8". HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING, INSTALLATION DETAILS WOOD STUD CON5TRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 hone: 909-356-6300 size FSC:M HO D1hG NO Pax 909-427-0634 A PNL-PLK-SOFF Creator. I- Gonzales SCALE 1/2" = t' o' Date: 4124/2013 s+eET 5 OA 12 Fastener Spacing per Florida Building Code Section 2322.3 16 in OC Cladding I ! • I • Framing Fastener Spacing per Florida Sheathin PRODUCT RENEWED Building Code Section 2322.3 9 F as complying with the Florida ' I Building Code INOA-No. 17-0406.06 •,_...__ __ 0.75in Expiral;lon D e05/01/2022 Miami-aBY- Miami- lYadre Product Control PRG WCT REV SED as vompiyiog with the 1 krigbk , awi Cods; ter ` se. 251n. mimo. Pe produa?T FRMINC NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-1/2' 16d COMMON NAILS (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING. NOMINAL 5/6" THICK / 5 PLY APA RATED PLYWOOD SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA BUILDING CODE SECTION 23=3 CLAQDJJ( G PLANKS. OVERLAP 1-1W THE EXPOSURE IS 58-1/4" THE PLANKS ARE FACE NAILED WITH 2-1/2• LONG, 0.223" HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION - RESISTANT SIDING NAILS, -PLACED 3/4' UP FROM THE BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION MoDUC17RI Vtsm S•• b onatpt with Itye ffta" I i ralS rzNo. 121 •`• ey i . de s1, O : STATE OF , 'qQ A SZONAL FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND NAVO LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION Jamea Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 A I I' PNL-PLK-SOFF 11 Stud Spacing at 16' O,C. li i PR a M Hdu WALL ii DigitIEIGHT tsy Mine i I .......... - - B 4--- 3W Minimum Edqe Distance QETAII Yu Flaria NGTH SEE PIIg01-1C7•DESC IP LQhI DETAIL HardiePlank6i,•Cemplank®, and 518^thick/ 5 piyAPn Prevails Plank Lap Siding materials rrated plywood r __....._.. __.._.... __._ / are nonasbestos fiber -cement ri sheathing fastened products tested In accordance with ASTM C1186 Grade II, Type A and 1: ! to metal studs as described In Note 1 meeting the requirements of the II t°• 1 ; (N '_! Florida Building Cade. Water resistive barrier per Florida )'L&, Ih K IgQWS_LQ•IS Building Code Width Length Thickness Section 1404.2 5 9-11T 12' 5/16" M7 4oc4dci Coe ut i ` 74 ; I I ': I ` 20ga, 34M' X 1.5/8' DESIGPR• ESSURE_RAIJ Metal l:rsWd N I F Installation Design Pressure HardiePlank, Metal Studs -92 _lsf L.._.-- _ ._ _ s • G\ 7 Cemplank, Prevail p cS' Lap Siding Impact Resistant — Nails at 16" O.C. (typ,) %DIVAL I 1-11a' tall X 5I18• Nick Starter ship APA Installed over 5/ 8" thick / 5 ply APA rated plywood sheathing Sheathing fastener, as described in Note 1 Siding fastener, as described in Note 2 IHardiePlank, Cemplank, Prevail Lap Siding Water -resistive barrier per Florida Building Code Section 1404.2 I ( 5/8" thick / 5 ply APA rated PRODUCT RENEWED L plywood sheathing fastened. to as complying with the Florida metal studs as described in, Building Code Note 1 NOA-No. 17- 0406.06 Expiration 05/01/ 2022 20ga, 3S/8" X 1-5/8" Metal C-stud The wall and soffit frames are to be designed By by the Architect or Engineer of Record in Miaml-ftdi Product Control compliance with the Florida Building Code. FIat2DIFplANfC CEMPI.ANIC, REVAIL P $Il7.j G 1N,S I Li?IQN DERAILS All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's Installation recommendations, and the applicable sections of the Florida Building Code. Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.OA Note 11 5/ 8" thick / 5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oo at panel edges and all intermediate supports using a No.B-18, 0.315" head diameter x 1-1/4" long bugle head screw Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4' wide laps at the top of the plank such that the exposure area of each plank is s 8-1/4" vertically. Note 2] The siding fastener shall be a minimum No. 8-18, 0.315" head diameter X 2-1W long' bugle head screw over metal studs (*or screw shall have at least 3 full threads penetrating metal framing); The siding is fastened s 8- IM' O.C. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 518" thick / 5 ply APA rated plywood sheathing,'fasteners are placed in the overlapping area approximately 3/4' from the bottom edge of the overlapping plank. Vertical joints shall be placed over studs. The planks shall be Installed over 5/8" thick / 5 ply APA rated plywood sheathing supported by a minimum 20ga, Nominal 3- 5/8" X 1-5/8" Metal Catuds spaced a maximum of 16" O.C. Fasteners shall have a minimum edge distance of 3/8". HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 Phone: 909-356- 6300 SIZE FSCM No Ow3 No Fax 909-427- 0634 A PNL-PLK SOFF Creator: E. Gonzales SCALE 112" 41'-0" Date: 4124/2013 1 SNEER' 7 OF 12 6.00in. I 6.00in. PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 _ 0.75in T' Explration,D te06/0112022 T By Miami-aMiarni-trafe Product Control 16 In. OC I 6. 00in.00 I I I. • I I . I it an cmaplyi a wi& die Flaride A, coptmoc No. i-•- - u l r oe 58. 251n. FR MIN NOMINAL 20 GAUGE 3.5/8" X 1-5/8" STEEL STUDS 16' O. C. FASTENED WITH SW LONG RIBBED BUGLE HEAD SCREWS ( 2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO 9E DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATh( ZJG ' NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6" OC AT -PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A NO. 8-18, 0.315" HEAD DIAMETER X 1-1/4' LONG BUGLE HEAD SCREW 9i Q.EIG PLANKS OVERLAP 1-1/4" THE EXPOSURE IS 5 8-1/4" THE PLANKS ARE FASTENED WITH NO. 8-18. 0.315" HEAD DIAMETER X 2-1/4' LONG CORROSION - RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING), PLACED 3W UP FROM THE BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION l i Cladding Framing Sheathing o I TATE OF ' c FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) tilHARDIEPLANK, CEMPIANK, PREVAIL LAP SIDING INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products,.inc. l10901ElmAvenueFontana, CA 92337 0hone: 909-3% 6300 Sir* rSCw rm owa No Fam 909-427-0634 A PNL-PLK-SOFF Creator. E. Gonzales SCAM 1" =1'-0" owe: 424/2013 S;Er 8 OF 12 1 ALL LENG1 Stud Spacing at 16" O.C. r I I i WALL IEIGHT i 3/8" Minimum 4QA1L,A Nails at 4" O.C. Distance Soffit fastener, as described in Note 1 PRODUCT RENEWED as complying with the Florida 1BuildingCode NOA-No. 17-0406.06 HardleSoffil, Cemsoffit Expiration e05/01/2022 By ' Miami- a e Product Control Io j Minimum 2" X 4" S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record In compliance With the Florida Building Code. P SEE DETAIL A I 2" X 4" S-P-F Wood Studs HardieSof% Cemsofnt bd SEA] L-N-BzB- typ•)PR6MC1' RSVL%W 9aawoyuvo0CCO& with I Ftorf4 gr t PM" Per . oi7tLc u sc lglrt0.(`i HardieSof * & Cemsoffit® materials are nonasbestos fiber -cement products tested in accordance with ASTM C1186 Grade 11, Type A and meeting the requirements of the Florida Building Code. SIQEELT IMEN$IOIJ3, Width Length Thickness 4' 8' 1/4" D15, gIQRR1-S_SU_RE8&T.1-N(j Installation Deslgn Pressure Wood Studs -70 psf OGAW/ No. 4 21 STATE OF JARDIESO- ff-EjCE.(VISGFFT NEL_[t IStQ1 4JJOnI pEJ.9.lLs All Installation shall be done In conformance with this Notice of Acceptance, the manufacturer's Installation recommendations, and the applicable sections of the Florida Building Code. Wood studs where HardleSoffit, Cemsofft will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. The soffit shall be installed over minimum Z%N1 S-P-F wood studs spaced a maximum of 16" O.C. Noto 1] The soffit fastener shall be a 2" tong, 0.223' head diameter, 0.092" shank diameter, corrosion resistant siding nail; the fasteners shall be spaced at 4" O.C. at panel edges and intermediate studs, the fasteners shall be driven into wood studs located at 16" O;C. Fasteners shalt have a minimum edge distance of 3/8" and a minimum clearance of 2" from comers. MODUCrRV4sM SURAVirtg ° 1e Fecrid. ANo 13•-0311,41 13y t ra& Pm&wt camw HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION SIZE I F'SCM NO James Hardie Building Products, Inc. 10001 Elm Avenue Fontana, CA 92337 PNL-PLK- SOFF Creator. E. Gonzales IscuE I - 1'-0" I bate: 41242913 ISHEET 9 OF 12 16.00in. Cladding Framing PRODUCT RENEWED as Complying with the Florida . Bullding Code NOA-No. 17-0406.06 Expiration Da 05101/2022 ey 4.00in.l Miamh Product Control PRtlbucr aEmED PRODUC IXE] LSFD t GA W ' B uldms cone ' A ID 1 ,07 oar o 007 N0. 121 Y * a Mirm tti..Aue1 Caa tol Miam' Ude ProEoet ComeW STATE OF E&A-M—LQ NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINLER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CkADDIN_ THE SOFFIT IS FASTENED WITH 2' LONG, 0.223" HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION RESISTANT SIDING NAILS, PLACE NAILS 4" O.C. AT PANEL E15GES AND INTERMEDIATE STUDS FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 Fax 909427-0634 A PNL-PLK-SOFF Creator. E Gonzales SCALE 1"=1=01 Date: 4/24/2013 SHEET 10 OF 12 WALL LENGTH — Stud Spacing at 16" O.C. ems_ i I i 3/8" Minimum DE C,,LI-6 PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Expiration By Distance w05/01 /2022 Nails at 6" O.C. (typ) Soffit fastener, as described in Note 1 HardleSoffit, Cemsoffit i 20ga, 3- W 41-50' Metal C-stud LThe wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code.. SEE PRODUCT DFC FZIf?71Q I OETAILA HardieSoffit® & Cemsoffit® materials are nonssbestos fiber -cement products tested in aeoordence with ASTM 01186 Grade II, Type Aand meeting the requirements of the Florida Building Code. toga, 3-518"X 1-5/8" SQU DIMJE_.$LQN_S, Metal C-stud Width Length Thickness 4' 8' HerdieSotfit, DESIGN ASSURE RATING I Cemsoffit Installation Design Pressure Metal Studs I/I W5OL". ttt3ttt' 1.OG3q SECTION t3RODUCY REWWO PRWVCTREVii£D V5conplyiogwkbonFlorida as cavoying with *4 F10rid 13url N0- Aeoop000ae No .0 I -al STATE OF B' I'rraAretCaotrol• Ns sdePwaeetCcn,trol t, •ORIDP •`V S NAL N lolls, E{Agp>;SOFFI CEMSOF_F_RPANEL 1NST 1L)7IOt DETAII$ . O rrflAllInstallationshallbedoneinconformancewiththisNoticeofAcceptan`&!.10 Ma{lufacturer's installation recommendations, and the applicable sections of the Florida Building Code. Metal studs where HardleSofBt, Cemsoffit will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O k The soffit shall be installed over minimum 20ga, Nominal 3-518" X 1-5/8" Metal C-studs spaced a maximum of 16" O.C. Note 1] The soffit fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-1/4' long' ribbed bugle head screw (*or screw shall have at least 3 full threads penetrating metal framing);the fasteners shall be spaced at 6" O.C. at panel edges and intermediate studs; the fasteners shall be driven Into metal studs located at 16" O.C. Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" fl'om comers. HAROIESOFFiT, CEMSOFFIT PANEL INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue a Fontana, CA 92337 hone: 909356-6300 s1zE 11scM No own No REV Fax 909-427-0634 A . PNL-PLK-SOFF 1 Creator. E.•Gorazles SCALE' irl" ,1'•0" I (late:4124/2013 smu 11 OF 12 6.001n. 16.1010in. Cladding Framing 6.O oin. I PRODUCT RENEWED ' I• MOiDUCr aEVISW waoao ' v.it6awftN a pRODs?aRob0 1h9FlOribrascomplyingwiththeFlorida Building Code gomm IPbs w9mo7s'S NOA-No. 17-0406.06 Aowrmw Bal"CA-epte.No 0-0311.07 matron /S Ir T//// ffii, gill AW 1 I Expiration 05/01/2022 JB ••• e'Hroi Miaml-DAdf Product Control ; I 0 , CC s w PLO SSI() i FRAIU iNG fiiif/Nl NOMINAL 20 GAUGE 3-516" X 1-5/8" STEEL STUDS 16. O.C. FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE AND BOTTOM FASTENED WITH WAFER HEAD SCREWS (2 PER TOP NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) AND BOTTOM CONNECTION) - THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CJAP-Q1111A HARDIESOFFIT, CEMSOFFIT PANEL THE SOFFIT IS FASTENED WITH NO. 8-18, 0.315" HEAD INSTALLATION DETAILS METAL STUD CONSTRUCTION DIAMETERX 1-1/4' LONG CORROSION RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 James Hardie Building Products, Inc. FULL THREADS PENETRATING THE METAL FRAMING), PLACE 10901 Elm Avenue SCREWS 6" O.C. AT PANEL EDGES AND INTERMEDIATE • at Fontana, CA 92337 STUDS Phone: 909-356-6300 srcE r-scm NO owa No RE Fax 909-427-0634 A PNL-PLK-SOFF 1 Creator. E. Gonzales saa.e 1" = 4 -0" Date: 4/24/2013 SHEET 12 OF 12 PROJECT RIO-2689-17 ENGINEERING EVALUATION REPORT FOR ATTACHING JAMES HARDIE® BRAND FIBER -CEMENT PANELS TO WOOD FURRING SOLUTIONS JAMES HARDIE BUILDING PRODUCTS, INC. 10901 ELM AVENUE FONTANA, CA 92337 TABLE OF CONTENTS PAGE COVER PAGE 1 EVALUATION SUBJECT 2 EVALUATION SCOPE 2 EVALUATION PURPOSE 2 REFERENCE REPORTS 2 TEST RESULTS 2 TABLE 1A, RESULTS OF TRANSVERSE LOAD TESTING 2 TABLE 1 B, ANALYSIS OF ALLOWABLE LOAD FOR #8 SCREW AT 10" O.C. 2 JUSTIFICATION OF USING THE RESULTS ON LIGHT GAUGE STEEL FRAMING 2 DESIGN WIND LOAD PROCEDURES 3 TABLE 2, COEFFICIENTS AND CONSTANTS USED IN DETERMINING V AND p 4 TABLE 3, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE B 4 TABLE 4, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE C 4 TABLE 5, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE D 4 TABLE 6, ALLOWABLE WIND SPEED (MPH) FOR HARDIEPANEL SIDING 5-6 AS PRODUCT EVALUATOR, THE UNDERSIGNED CERTIFIES THAT THE LISTED PRODUCTS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE ASCE 7-10, THE 2017 FLORIDA BUILDING CODE, AND THE 2015 INTERNATIONAL BUILDING CODE. PREPARED BY: RONALD I. OGAWA & ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX RONALD 1. OGAWA ASSOCIATES, INC. 161135 ALGONOUIN STREET 0"3 HUNTINGTON BEACH, CA 92649 1) 714-292-2602; (F) 714-847-4595 PROJECT: RIO-2669-17 EVALUATION SUBJECT HardlePaneW Siding James Hardie Product Trade Names covered In this evaluation: HerdiePanel6 Siding, CempeneW Siding, Prevail- Pend Siding EVALUATION SCOPE: ASCE 7.10 2017 Florida Building Code 20151nternadoral Building Code 2015International Residential Code JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 Wo@jameshardie.com EVALUATION PURPOSE: This analysts Is to determine the mammum design 3-second gust wind speed to be misted by an assembly of HardlePanel (Cempenel. Prevail Panel) siding fastened to wood Turnings on dther wood or metal training with nails or screws. REFERENCE REPORTS: 1. Interlek Report 102024363000-OOtA, Transverse Iced lest on HardiePend TEST RESULTS: Table /a. Results of Transverse Load Testing Frame Fastener Ulumate Allowable Test Thidmess Width Spacing Spacing Fastener Type Load Design Loeb: Report Number Agency m. et. Frame Type ' m. in.) and Dimensions PSF) PSF) Falhse Mode 102024363COO-OD1A Intenak 0.3125 48 2X4 wood stud, 314' thick by 3.5' wide SPF furring 16 6 No. 8 X 1.25' long X 0.323' HD ribbed bugle head dews 160.7 53.6 pull through /fracture 102024369000.001A Imenek 0.3125 48 2X4 wood stud. 314' thick by 16 8 No. 8 X 1.25' long X 0.323' HD 131.4 4&8 pug through 3.5' wide SPF furring ribbed bugle head screws 102024383COO-OD1A Intenek 0.3125 48 2X4 wood stud, 3/4'thick by 16 12 No. 8 X 1.25' long X 0.323' HD 106.1 35.4 pull through 3.5' wide SPF furring ribbed bugle head screws 102024363000.001A Intenek 0.3125 46 2X4 wood stud' 3(4- Usdk by 16 6 0.090' shank X 0.215' HD x 1.5' t47.6 49.2 Pun through /fracture 3.5' wide SPF fuming long wing shank rail 102024363000-001A Intertek 0.3125 48 2X4 wood stud, 314' tNdk by 24 6 No. 8 X 1.25' long X 0.323' HD 82.7 27.6 pull through /fracture 3.5' wide SPF furring ribbed bugle head screws 1. All fasteners were installed on tuning without penetration into the framing members. 2. Allowable load Is delermiried from ultimate load divided by a factor o1 safety of 3. 3. HaroiePanal Siding complies with ASTM C1186, Standard SpecOwlion for Grade fl, Type A Non -asbestos Fiber -Cement Flat Sheets Table 1b. Analysis of Allowable Load for 98 Screw at IV O.C. 98 Screw Spacing Fastener Spacing (in.) 8 12 10 Frame s tirr In. 16 16 16 Fastener Tnbuta area lt' 0.89 1.33 1.11 Allowable load 43.8 35.4 38.8 Individual fastener load b. 38.9 47.2 43.1 The fastener load for 98 screw 9110' O.C. was calculated as the average of the test results for 6' and 1Y O.C. The allowable load for e8 screw at the spacing of Vr O.C. Into furring can be calculated by interpolating the results of same fastener at 6' and 12' O.C., since both teals had same failure mode o1 fastener pug through from the panels. As shown in the able, the allowable load for 08 screws installed at 10' O.C. to wood furring is 38.8 psi. Justification of Using the Results on Light Gouge Steal Framing In the vAccl configurations. an fasteners were attached to furring only, so whether the hung is attached to wood or sled framing does not affect panels' transverse load capacity. It's the pro)ed engineer's responsibility to ensure the furring a0aduent and training memebers to have sufficient load capadties. RONALD 1. OGAWA ASSOCIATES, INC. 16635 ALGONQUIN STREET 0443 HUNTINGTON BEACH, CA 92649 T) 714-292-2602; (F) 714-847-4595 PROJECT: RI0-2669-17 JAMES HARDIE BUILDING PRODUCTS, INC. I-OW542-7343 inloGjameshardie.com DESIGN WIND LOAD PROCEDURES: Fiber -cement siding transverse load capacity (vend load rapacity) is determined vta compliance testing to Um verse load national test standards. Via the transverse load testing an allowable design load is determined based on a facto of safety of 3 applied to the ultimate test load. Equation1, q6-0.00256-VK.-KfVT (ref.ASCE 7.10equation 30.3-1) q, . velocity pressure at heigN z K, , velocity Pressure exposure Coefficient evaluated ef hergN z Ka , topographic factor Equation 2. K. , wind directionality factor V , basic wind speed (3-second gust MPH) as determined from 2015 IBC Figures 1609.3(1), (2), or (3); ASCE 7-10 Figures 2&S-1A, B, or C V= V,a (wet. 2015 IBC Section 1602.1 de9ni(Pons) Vw , ultimate design wind speeds (3-second gust MPH) determined from 2015 IBC Figures 1609.3(1), (2). or (3); ASCE 7-10 Figures 26.5.1& B, or C Equation 3, p=V(GC.GC,) (ref. ASCE 7-10 equation 30.6.1) GC., product of external pressure coefficient and gust -effect factor GCO . product of internal pressure coefficient and gust -effect rector P , design pressure (PSF) fo siding (allowable desgn load for siding) To determine design pressure,, substitute q, into Equation 3, Equation 4, P=0.00256'K.'Ka'K.'V,."(GC.-GC,.) Allowable Stress Design, ASCE 7.10 Secbon 2.4.1. load combination 7 Equation 5, 0.6D • 0.6W fret. ASCE 7-10 section 2.4.1. food combination 7) D . dead load W , wind load To determine the Allowable Stress Design Pressure, apply the load factor for W (wind) from Equation 4 to p (dawgui pressure) determined from equation 4 Equation 6, P.W - 0.6'(P) EquationT. per.-D.610.00256'K.'K,.•K.'V,as'(GC,GCj) Equation 71s used to populate Table 3. 4, and 5. To determine the allowable u&mere basic wind speed for Hardie Siduig in Table 6, schv Equation 7 for V,., Equation 6, V. _(p.M.6.0.OD256•K,'K.'K.'(GC.GC,,,))" Applicable to methods spaciaed in Exceptions 1 through 3 of 2015ISC SecW 1609.1.1., to determine Oro allowable nominal design wind speed (Vasil) for Hardie Srtlerg in Table 6, apply the WnveMbn lbmrtrla bebW. Equation 9, V. - V. - (0.6)" /ref 201518C Section 1609.3.1) V_. , Nominal design wind speed (3-second gust mph) /wet. 2015 IBC Secbort 1602.1) 0 RONALD I. OGAWA ASSOCIATES, INC. 16835 ALGONOUIN STREET 0"3 HUNTINGTON BEACH, CA 92649 1) 714-292-2602; (F) 71"47.4595 PROJECT: RIO-2689.17 Table Z Coefficients and Constants used in Determining V and P, K, Wag Zone 5 Height (it) Exp B Exp C Exp D K. Ke GC GC 0-15 0.85 1.03 h960 1 0.85 1.4 018 20 0.9 1.08 1 085 1.4 0,18 25 0.94 112 1 0.85 1.4 0.18 30 0.98 1.16 1 0.85 1.4 0.18 35 1.01 1.19 1 0.85 1.4 0.18 40 E0.755 1.04 1.22 1 0.85 1.4 0.78 45 7.065 1.245 1 0.85 1.1 0.18501.09 1.27 8 1.1 018551.11 1.29 1 0.85 1.1 0.18601.131.$1 0.85 1.1 0.t810016r1.43 h>W 1 0.85 1.8 a18 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888542-7343 inio@jemesherdie.com Table 3, Allowable Stress Design - Component and Cladding (C3C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category B, nd Speed 3-secondoust) 100 105 110 115 120 130 140 150 160 170 18D 190 200 210 Height A B B B B B B B B B B B B B B 0.15 14.4 15.9 17.5 19A 20.8 24.4 2&3 32.5 37.0 41.7 46.8 52.1 67.8 63.7 20 14A 15.9 17.5 191 20.8 24.4 26 3 32.5 37.0 41.7 46.8 52.1 57.0 63.7 25 14.4 15.9 17.5 19.1 20.0 24 4 28.3 32.5 37.0 41.7 45.0 52.1 57.8 63.7 30 14A 15.9 17.5 19.1 20.0 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 35 15.1 16.6 1&2 1&9 21.7 25.4 29.5 33.9 38.6 43.5 4&6 54.4 60.2 66.4 40 15.7, 17.3 19.0 20.7 22.6 26.5 30.7 35.3 40.1 45.3 50.8 56.6 62.7 N.1 45 1&2 17.9 19.6 21.4 23.3 27A 31.7 36.4 41.5 46.8 57-5 58.5 64.8 71.4 50 16.7 18.4 202 22.1 24.1 282 37-7 37.6 42.8 48.3 54.1 60.3 66 8 73.7 55 17.1 18.9 20.7 22.8 24,7 28.9 33 6 38.5 43.1 49.5 55.5 61.8 68.5 76.5 t B. 4 100 25.6 28.2 31.0 33.8 36.9 43.3 502 57.6 65.5 74.0 62.9 92.4 102.4 112.9 Table 4, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category C. d Speed 3-seaDndgust) 1DD 105 110 115 120 130 140 150 '1 160 170 180 190 200 210 Height (it) C C C C C C C C C C C C C C 0.15 17.5 19.3 21.2 23.2 25.2 29.6 34.4 39.5 44.9 50.7 56.8 63.3 70.1 77.3 20 18.6 20.5 22.5 24.6 26.7 314 36.4 61.8 47.5 53.7 60.2 67.0 74.3 81.9 25 19.4 21.4 23.5 25.6 27.9 32.8 38.0 43.6 49.6 56.0 62.8 70.0 77.6 85.5 30 20.2 22.3 24.5 26.7 29.1 34.2 39.6 w5.5 51.8 564 65.5 73.0 8D.9 89.2 35 20.8 23.0 252 276 30 0 35.2 40 6 46.9 53.3 60.2 67.5 75.2 83.3 91 9 40 21.5 23.7 26.0 2&4 30.9 36.3 4Z0 48.3 54.9 62.0 69.5 77.4 85.8 94.6 45 22.0 24.2 26.6 29.1 31.6 1 -37.1 1 -43.1 49.4 56.2 63.5 71.2 79.3 87.9 96.9 50 22.5 24.8 272 29.7 311 38.0 14.1 50.6 57.6 65.0 72.9 612 69.1 98.2 S5 22.9 252 27.7 30.3 33.0 38.7 44.9 51.5 58.6 66.2 74.2 02.7 87,6 101.0 50 233 2 39.4 4 1 100 U6 35.9 39.4 43.1 469 55.0 63.8 73.3 1 53.4 94.1 105.5 1 -117.6 1 •130.3 143.8 Table 6, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds • Wind Exposure Category D, tl S 3-secondgust) 100 105 110 115 120 130 140 150 160 170 180 190 200 210 Height (R) D D D D D O D D D D D D D D D-15 21.2 23A 25.7 2111 30.6 35.9 41.5 47 8 54,4 61.4 68.8 76.7 65 0 43.7 20 22.3 24.6 27.0 29.5 32.1 37.7 43 7 50.1 57.0 64.4 72.2 90.4 89.1 98.2 25 231 25.5 28.0 30.6 33.3 39.0 45.3 52.0 591 66.6 74.9 83 4 824 101.9 30 23 9 26.4 29.0 31.6 34.5 40.4 J6 9 53 a 61.3 69.2 77.5 86.4 95.7 105.5 35 24.5 27.1 29.7 325 35.3 41.5 481 55.2 67-8 70.9 79.5 88.6 98.2 108.3 40 25.2 27.7 30.5 33.3 36.2 42.5 49.3 58A 64.4 72.7 F5 90.9 100.7 111.0 45 25.7 28.3 31.1 34.0 37.0 13.4 50 3 57.8 65.7 74.2 83.2 97-7 102.7 113.3 50 26.2 28.9 31.7 34.6 37.7 44.3 51.3 58.9 67.1 75.7 84.9 94.6 104.8 115.5 55 26.6 29.3 322 35.2 38.3 45.0 5,Z2 59.9 68.1 76.9 66.2 86.1 106.4 117.4 so 9.8 4 1 .1 1 . 1D0 37.0 40.6 44.7 48.9 53.2 62.5 72.5 63.2 94.8 t06.8 119.8 133.4 147.9 163.0 Tables 3, 4, end 5 are besetlxn ASCE 7-10 and consistent with the 2015 IBC, 2015 IRC pGAWA RONALD I. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET "43 HUNTINGTON BEACH, CA 92649 T)714-292-2602;(F)714-847-4595 PROJECT: RIO-2689.17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-S42-7343 info@jameshardle. corn Table 6, Allowable Wild Speed (mph) for HardiePonel Siding (AnaVical Method In ASCE 7-10 Chapter 30 CdC Pall 1 and Part 3)' Design Wnd, Speed, V.ss Applicable to methods specified in 12015 IBC, 2017 FBq Section 609 1.1. as detemdned b Pin 518C, 2017 F9q Figures 1600.3(t), (2). or 3). 11.e --., rw ,d-- Allowable, Normnd Design Wind, Speed, Vr 4s, Applicable to methods specified in Exceptions 1 though 3 of 1201619C. 2017 FBCI Section 1009.1.1. used in Table 9 calculations for Product MinimumFastener Thickness can.) Width in.) Fastener Type Spacing Frame Type Stud Spacing Building Hdghlt e 00 B C D B C D Allowable Desrpu LoM PSI) ExpB E1pC Em0 Kn K. OC. GCr HardiePeneW Sme 48 No. B % 1.26' long X 0.323' HD ribbed bugle head scre" 6' O C. Into paring only 2X4 wood or 20 ga. steed framing. 3!1' thick by 3.5' wide wood fumng 1•ra 16 D•15 193 176 159 149 135 123 53.6 0.70 0.85 1.03 h$60 1 D.65 14 0.18 20 193 170 155 149 132 120 53.6 0.70 0.90 1.08 1 0.05 IA 0.18 25 193 166 152 149 120 118 53.6 0.70 0.94 1.12 1 0.65 1.4 0.10 30 193 153 150 149 126 116 53.6 0.70 0.9e 1.16 1 0.95 1.4 0.18 35 189 160 148 6 124 114 SS 6 0.73 1.01 1.19 1 0.85 1.4 0.14 40 185 15e 146 143 122 113 53.6 0.76 1.04 722 1 0.65 IA 0.19 45 172 150 140 133 116 108 33.6 0.113 1.15 1.33 1 0.85 14 0.10 50 179 154 143 139 120 111 WA 0.81 1.09 1.2 1 0.85 1.4 0.18 55 177 153 142 137 119 110 63.6 0.W 1.11 12B 1 085 1.4 0.18 60 175 152 14l 135 117 109 S3 6 0.65 1.13 1.31 t 0.85 1.4 0.18 1D0 145 128 120 112 99 93 WA 0.99 126 1.43 hW t 0.95 1.0 0.18 HardlePand® 5116 49 No. a X 125! king X 0.323' HD ribbed bugle head screws B' O.C. into furring only 2X4 wood or 20 ga. Glad training, 314' thick by 3.b' wide wood furring ,,7a 16 0.15 174 158 144 135 122 111 43 a 0.70 0.95 1.03 h!0 1 0.55 1.4 018 20 171 154 110 135 119 109 43.8 0.70 0.90 1.0e 1 0.85 1./ 0.18 25 174 150 138 135 116 107 43.8 0.70 0.94 1.12 1 0.85 1 4 D.18 30 174 147 135 135 114 105 43.0 0.70 0.90 1.16 1 OILS 1.4 0.18 35 171 145 134 132 112 103 43.8 0.73 1,01 1.19 1 0.0.5 1.4 Fill 40 167 143 132 129 111 102 43.8 0,76 1.04 172 1 0.a5 1.1 0.16 45 164 141 131 127 109 101 Z.8 0.79 1.07 125 t 0.55 14 0,15 50 162 140 129 125 108 100 43.8 0.61 1.09 127 1 0.65 1.4 0.10 55 160 138 128 124 107 99 43.8 0.03 1.11 129 t O.B.S 1.1 0.18 60 158 137 127 122 106 99 ems.$ 0.65 1.13 1.31 t 0.a5 1.4 0.1a 100 131 116 1D7 90 3.8 0.99 126 1.43 ha60 t 0.65 1.8 0.18 HtudiePenel® 5Jt6 18 No 8 X 12S long 0.3lon ribbed bugle headbugle screws 70' O.C. Into tuning only 2X4 wood or i20 go. eel20go. sled wide w odwidewood tuning '.rx le 0.15 164 149 135 127 115 105 so.$ 0.70 0.55 1.03 hs80 1 0.85 1.4 0.14 20 164 145 132 127 112 102 36.a 0.70 0.9D 108 1 0.85 1.4 OAe 25 184 141 130 127 110 100 M.8 0.70 0.94 1,12 1 0.05 1 4 0 to 30 164 139 127 127 107 99 381 0.70 0.96 1.16 1 O.a5 IA 0.15 35 161 136 126 124 105 97 38 8 0.73 1.01 1.18 t 0.65 1.1 0 1a 40 157 134 124 122 tOd 96 38.8 0.76 1.04 122 1 US 1. 4E0.1 45 155 133 123 120 103 95 30 8 0.79 1.07 125 1 0.e6 1.4 50 152 131 122 Yta 102 94 3s2 0.81 1.09 127 1 0.0.5 1./ 55 151 130 121 117 101 94 33.8 0.53 1.11 129 1 0.05 1.4 60 149 129 120 115 10D 93 35.8 0.6.5 1.13 1.31 1 0.65 1.1 100 123 95 38.8 0.99 125 1.43 ha60 1 0.05 1.8 HardiePaned® Sn6 48 No. 8 X 125' long 0.323' HD ribbed bugle freed Screws 12' O.C. Into baring only 2X4 wood or 20 ga. sled framing, 3/1' thick by 3.5' wide wood furring •,t4 16 0.15 157 142 129 121 110 100 35.4 0.70 0.85 1.03 h%W 1 1 0.55 1.4 20 167 138 126 121 107 98 36.4 0,70 0.90 1.08 1 GAS 1.1 25 167 135 124 121 105 96 354 0.70 0.94 1.12 1 0,85 1.4 0-le 30 157 132 122 121 103 94 35.4 0.70 0.93 1,16 1 O 1.4 0.18 35 153 130 120 119 101 93 354 0.73 1.01 1,19 t 0.85 IA 0.18 40 150 128 119 116 100 92 35.4 076 1.04 122 t 0.65 1.1 0.18 45 148 127 117 115 98 of 35A 0.79 1.07 115 1 0.55 1.1 0.18 50 U6 125 116 113 97 go 354 0.51 1.09 127 1 0.85 1.4 cite 55 114 124 115 Ill 96 89 354 0.83 1.11 129 1 085 4.4 018 60 142 123 114 110 95 89 35.4 0.85 1.13 1 1 1 0.115 1.4 618 100 1 lie 91 35.1 1 0.98 1 126 1 143 1 h>601 1 10.05 1 •1.6 10.118 RONALD I.OGAWA ASSOCIATES, INC. JAMES HARDIE BUILDING PRODUCTS, INC. 16835 ALGONQUIN STREET *443 1-888-542-7343 HUNTINGTON BEACH, CA 92649 into@jameshardie.com m 714-292-2602; (F) 714-847-4595 PROJECT: RIO-2689-17 Allowable, Ultimate Allowable, Nominal Design NMd. Speed, Design V4nd. Speed. V,su, V.r a, 3-second gust mph) 3asoond gust mph) Applicable to methods specified of J20151BC. Applicable to mcNods 2017 F8C) Section specified in Exceptions 1 w 1609.1.1. as determined by through 3 611201518C, 12015 IBC, 2017 FBC) 2017 FBC) Section Figures 1609.3(1), (2). or 1609.1.1. 3) CoeffiCienb used In Table 6 nkubtiolts for Wnd elmOSurecatenory Vdnd exposure calectory Sidno K Product Mudmum Thickness in.) Width Fastener Type Fastener Spacing on.) Frame Type Stud Spaanp h) Building Heighl'•s 00 B C D B C D Allowable Design LOW Iwl) Enp8 ErpC ExpD K, I K. GC. GCy Hardit7Penel® 5/76 48 No. 8 % 1.25' long X 0.323' HD ribbed bugle head screws W O.C. into furring only 2X1 wood fJ 2098. steel framing, 3/4' tick by 3.5' wide wood flaring r•1r 24 0.15 138 125 114 107 97 68 27.5 0,70 0.65 1.03 hSW 1 0.55 1.4 0.19 20 138 122 111 107 94 a8 27.6 0.70 0.90 1.08 1 0.65 1.4 0.18 25 138 119 107 92 27.6 0.70 0.94 1.12 1 on 1.4 ate 30 138 117 107 91 27A 0.70 0.98 716 t 0.a5 1.4 0.18 35 135 115 10S Be 27.6 0.73 1,01 1.19 1 0.a5 1.4 0.16 40 133 113 103 88 27.6 0,76 1.04 122 1 OAS 1.4 0.18 45 131 112 101 87 27.6 079 1.07 1.25 1 0.65 1.4 0.18 50 129 111 100 86 27.6 Oat 1.09 127 1 0.96 14 0.1a 55 127 98 27.6 083 111 1.29 t 0.65 1.4 0.18 60 125 97 27.8 0.95 1.13 1.91 I 1 I 0.65 1.4 0.18 100 27.5 0,99 125 1.43 h>60 1 ma5 1.0 0.16 HerdfePenellD 5116 48 Q097 shank % 0.215' HD x 1.5' long nng shw* nail 8. O.C. into Raring Only 2X4 wood or 20 go. steel framing, 314' thick by 3.5' wide wood ryydng 16 0.15 185 168 152 143 130 118 492 070 0.85 1.03 h$W 1 0.05 1.4 018 20 185 163 149 143 126 115 492 0.70 0.90 1.03 1 M95 1.4 0.18 25 185 159 146 143 123 113 492 070 0.94 1.12 1 0,85 1,4 0.18- 30 195 1S6 143 143 121 111 492 0,70 0.Po 7.16 1 0.95 1.4 0.18 35 78t 154 142 740 119 110 92 073 1.01 7.19 1 0.85 1.4 0.16 40 177 161 140 137 117 108 J9.2 0.76 1.04 122 1 O.a5 14 0.18 45 174 150 138 135 116 107 492 0.79 1.07 125 1 0.85 14 0.18 50 172 148 137 133 115 106 492 0.81 1.09 127 1 0.85 1.4 0.15 55 170 147 136 131 114 105 49.2 0.83 1.111 129 t 0.65 1.4 0.18 60 168 145 135 130 113 105 9.2 O.eS 1.13 1.31 1 0.aS 1.4 0.16 100 139 123 115 1D7 95 89 492 0.99 1 126 1 1.43 1 ha60 t 10.85 1 -1.0 0." 1. Furring shachmem to Structural lramng merrmem or ahem@ M fumng v4dLh shall be designed by an ongnser. 2. Bulking height • mean rot height (m feel) of a building, 9=pt that save height shall be used for roof angle gloss than or equal to 10' (2.12 roof Slops). 3. V. s uhrrrste design wend speed 4. Vim. - non hW design wind speed 5. Linear interpolation of building height IS 60 fi) and wind speed is pamdhed. 6. Wind speed design assurroons per Am"I Method n ASCE 7.10 Chapter 30 C&C Pon 1 and PM 3• K ss1, ".85. GCrs•lA (ItS60), GCea1 8 (ha6D), GCfO 10. 7. Wood tuning shag be pretervatrwe treated per AWPA. a. Wbod furnng shag be spectf¢ gravity of 0.42 or greater par AFPAMDS: of wood structural panel, cm tormbtg to DOC PSt or DOC PS•2 or APA PRP•108. LIMITATIONS OF USE: 1) In High Velocity Hurricane Zones (HVHZ) install per MiamFDade County Florida, NOA 17-0406.06 It III011 ii".:' AWA NSE' = cc 12 c FLpR\OP.'S`',, 2 '• •.......•• FFSSION P_711' 17 PROJECT RIO-2686-17 ENGINEERING EVALUATION REPORT FOR ATTACHING JAMES HARDIE® BRAND FIBER -CEMENT PANELS TO WOOD AND METAL FRAMED WALLS WITH VARIOUS FASTENERS JAMES HARDIE BUILDING PRODUCTS, INC. 10901 ELM AVENUE FONTANA, CA 92337 TABLE OF CONTENTS PAGE COVER PAGE 1 EVALUATION SUBJECT 2 EVALUATION SCOPE 2 EVALUATION PURPOSE 2 REFERENCE REPORTS 2 TEST RESULTS 3 TABLE 1A, RESULTS OF TRANSVERSE LOAD TESTING 3 TABLE 1 B, SHEAR VALUES 3 DESIGN WIND LOAD PROCEDURES 4 TABLE 2, COEFFICIENTS AND CONSTANTS USED IN DETERMINING V AND p 4 TABLE 3, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE B 5 TABLE 4, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE C 5 TABLE 5, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE D 5 TABLE 6, ALLOWABLE WIND SPEED (MPH) FOR HARDIEPANEL SIDING 6-7 LIMITATIONS OF USE 7 AS PRODUCT EVALUATOR, THE UNDERSIGNED CERTIFIES THAT THE LISTED PRODUCTS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE ASCE 7-10, THE 2017 FLORIDA BUILDING CODE, AND THE 2015 INTERNATIONAL BUILDING CODE. . PREPARED BY: RONALD I. OGAWA & ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4'595 FAX RONALD I. OGAWA ASSOCIATES, INC. 16835 ALGONOUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-26W17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info(dl1amesha rdie.com EVALUATION SUBJECT HardtePanetO Siding James Hardie Product Trade Names covered in this evaluation: HardiePanel® Siding, Cemparnel(l) Siding. Prevail"' Panel Siding EVALUATION SCOPE: ASCE 7-10 2017 Florida Building Code 2015 International Building Code® EVALUATION PURPOSE: This analysis Is to determine the ma*num design 3-second gust wind speed to be resisted by an assembly of HardiePanel (Cempanel, Prevail Panel) siding fastened to wood or metal framing with nags or screws. REFERENCE REPORTS: 1. Intertek Report 3067913 (ASTM C1186) Material properties HardiePanel Siding 2. Ramtech Laboratories Report IC- 1270-94 (ASTM E330) Transverse Load Test 5116' Thick by 48 inch wide HerdnePenel Siding installed on 2X4 Hem -Fa wood studs spaced at 16 urcAes on tender with a 6d common galvanized nall 3. Ramtech Laboratories Report IC-1271-94 (ASTM E330) Transverse Load Test, 5/16' Thick by 48 inch wide HardlePenel Siding installed on 2X4 Hem -Fir wood studs spaced at 24 Inches on center with a 6d common galvanized rha8 4. Ramtech Laboratories, Inc. Report 10868-9711475 (ASTM E330) Transverse Load Test 5116' Thick by 48 inch wide HardiePanel Siding Installed on 2X4 Group III SG=0.36 wood studs spaced at 16 inches on terrier with a 4d, 0.091 inch shank by 0.225 inch head diameter by 1.5 Inch long ring shank nail S. Ramtech Laboratories, Report IC.1054-89 (ASTM E330) Transverse Load Test 114' Thick by 48 inch wile HardiePanel Siding installed on 20gauge Metal studs spaced at 16 Inches on center with a No 8 X 1 in. king X 0.323 in head diameter ribbed bugle head screw 6. Ramtech Laboratories, Report 161055-N (ASTM E330) Transverse Load Test, 114' Thick by 48 Inch wide HardhePenel Siding installed on 20gauge Metal studs spaced at 24 inches on tender with a No 8 X 1 In. long X 0.323 In head diameter ribbed bugle head screw 7. Remteeh Laboratories, Report 11149.98/1554d (ASTM E330) Transverse Load TesL 1/4' Thick by 48 Inch wide HardiePanel Siding Installed on 20gauge Metal studs spaced at 16 and 24 inches on center with a ETBF 0.100 in. knurled shank X 1.5 in. long X 0.25 in. head diameter pin fastener 8. Ramtech Laboratories Repo" IC-1273-94 (ASTM E72) Racking Shear Test, 5116' Thick by 48 rich wide HardiePand Siding installed on ZX4 Hem -Fir wood studs spaced at 16 Inches on center with a 6d common galvanized nail 9. Ramtech Laboratories Report IC-1274-94 (ASTM E72) Racking Shear Test SMS' Thick by 48 Inch wide HardiePanel Siding Installed on 2X4 Hem-FI wood studs spaced at 24 Inches an center with a 6d common galvanised nag 10. Ramlerh Laboratories, Inc Repo" 10868-97/1475 (ASTM E72) Racking Shear TesL 5/16' Thick by 48 inch wide HardiePanel Siding installed on 2X4 Group III SG-0.36 wood studs spaced at 16 inches on center with a 4d, 0.091 inch shank by 0.225 inch head diameter by 1.5 inch long ring shank nag 11. Ramtech Laboratories Repo" IC-1057-89 (ASTM E72) Racking Sheen Test, 5/16' Thick by 48 inch wide HardiePenel Siding installed on 2X4 Hem -Fr wood studs spaced at 16 and 24 Inches on tamer with a No 8 X 1 In. long X 0.323 in head diameter ribbed bugle head screw 12. Ramtech Laboratories Report 11284-99/1580 (ASTM E72) Racking Shear Test, 5116' Thick by 48 inch wide HardleParhel Siding installed on 2X4 Hem -Fir wood studs spaced at 16 and 24 Inches on terrier with a ETdF 0.100 in. knurled shank X 1.5 In. Irmg X 025 in, head diameter pin fastener ffifffffilAre "," " OGAINq " SF' _ 1 - 1• STATE OF RID JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 intoMameshardie.cor n TEST RESULTS: Table 1 a, Results of Transverse Load Testing RONALD I. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET "43 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT, RIO.2686-17 Fastener Spacing tin.1 Allowable Frame Ultimate Design Thicknessk48th Spacing Perimeter Feld Load Load' Report Number Test Ape m.) Frame T in.) Supports Supports Fastener T PS PSF IC-1270.94 Ramledt 0.3125 2X4 wood Hem -Fr 16 6 6 6d common 149 49.7 IG1270-94 Rermech 0.3125 ZX4 wood Hem -Fir 16 4 4 6d common 236 78.7 IC-1271-94 Ramtecit 0.3125 2X4 wood Hem -Fir 24 6 6 6d common 94 31.3 IC-1271-94 Ramtech 0.3125 2X4 wood Hem -Fir 24 4 4 60 common 143 47.7 0.In. shank X shank in 10868-97/1475 Ramtech 0.3125 48 2X4 wood. SG 2 0.36 16 4 6 HDD % 1..55 in. ring shank hell 90 30.0 Min. No 8 X 1 g X 0,323 inin. long IC-1054 89 Ramtech flak 48 Min. No. 20 gouge X 3.625 it. X 16 6 6 head diameter ribbed bugle 169.9 56.6 1.375 in metal stud head screw Min. No 8 X 1 in. king X 0.323 inIG705569Remtedt0.25 48 Min. No. 20 gauge X 3.625 it. X 24 6 6 heed diameter ribbed bugle 91.9 30.6 1,375 it metal stud head screw ET&F 0.100 loth knurled shank X 11149-98/1554d Ramtech 0.3125 46 Min. No. 20 gauge X 3.625 in. X 16 4 8 1.5 in. long X 0.25 in. head 170 56.7 1.375 In metal stud diameter pin fastener ET&F 0.100 in. knurled shank X 11149.98/1554d Ramtech 0.3125 48 Min. No. 20 gauge X 3.625 In. X 24 4 8 1.5in. long X 0.25 in. head 101 33.7 1. 375 in metal stud diameter pin fastener 1. Allowable Load is the Ultimate Load divided by a Factor of safety of 3. Z. HardiePonel Siding complies with ASTM C1186, Sfandard Spedliication for Grade If, Type A Norrasbestos Fiber -Cement Flat Sheets. Table 1b, Shear Values Allowable Loads In Pounds Per Lineal Foot for Panel Shear Wells'-t Fastener Spacing rib1 Frame Ultimate Allowable Thickness Width Spacing Perimeter Feld Loads Load' Report Number Test Agency jinn.) in.) Frame Type in.) supports Supports Fastener T elf) IC1Z73- 94 Ramtech 0.3125 48 ZX4 wood Hem -Fr 16 6 6 6d common 603.8 201.3 IC- 1273 94 Ramtech 0.3126 48 2X4 wood Henn -Fir 16 4 4 6d common 698.8 232.9 IC- 1274-94 Ramtech 0.3125 48 2X4 wood Hem -Fr 24 6 6 6d cmnmon 460.0 153.3 IC. 1274-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 24 4 4 6d common 637.5 212.5 4d, 0.081 m.shank X n. 10868- 97f1475 Ramtech 0.3125 48 2X4 wood. SG 20.36 16 4 g shank h0.a H1.5 in. loop ring shank nail D X595.4 198.5 Min. No 8 X 1 in. long X 0.323 in G1057-89 Ramtech 0.25 48 Min. No. 20 gauge X 3.625 in. X 16 & 24 6 6 head diameter ribbed bugle 990.0 123.8 1375 in metal stud read screw ET&F 0.100 in. knurled shank X 11284-99/ 1580 Ramlech 0.3125 48 Min. No. 20 gauge % 3.625 in. X 16 4 8 t.5 in. lone X 0.lot, head 1227.0 153.4 1.375 In metal stud la diameter pinfastenerET&F 0.100 in. knurled shank X 1128499/1580 Remtech 0.3125 48 Mln. No. 20 gauge X 3.625 In. X 24 4 8 1.5 in. long X 0.25 in. head 1060.0 132.5 1.375 in metal stud diameter pin fastener 1. WI Daaro edges shall De bupponeo cry rramrip. i-aners Flab De appiran wrtn ine long aimension eurer parHgel yr perperwrcraar tv c1aa5. 2. The maximum height-loaength ratio for construction in this Table is 2:1. (1 0 G A 'pit' - 3. In the slat] namedassembliestheallowableloadisbasedontheaverageloadat118Inchnetdeflection. Q . Vv o SW F cc\% FsS ONA lff yy Wall Zone 5 Height (it) Exp B I Exp C Exp D K„ w GC GC 0-15 0.7 1 0.85 1.03 hs60 1 0.85 1.4 0.18 20 0.7 0.9 1.08 1 0.85 1.4 0.18 25 0.7 0.94 1.12 1 0.85 1.4 0.18 30 0.7 0.98 1.16 1 0.85 1.4 0.18 35 0.73 1.01 1.19 1 0.95 1.4 0.18 40 0.76 1.04 1.22 1 0.85 1.4 0.18 45 0.785 1.065 1,245 1 0.85 1.4 0.18 50 0.81 1.09 1.27 1 0.85 1.4 0.18 55 0.83 1.11 1.29 1 0.85 1.4 0.18 60 1 0.85 1 .13 1.31 1 0.85 AA 0.18 100 1 0.99 1 1.26 1 1.43 1 Iv60 1 0.85 1.8 1 Ole RONALD I. OGAWA ASSOCIATES. INC. 16835 ALGONQUIN STREET 8443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-26B6-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com DESIGN WIND LOAD PROCEDURES: Fiber-rsmem siding transverse load capably (wind load capacity) is determined via compliance testing to transverse bad national test standards. Via the transverse load testing an allowable design load is determined based on a factor of safety of 3 applied to the ultimate test bad. Sine the allowable design load is based on factor of safety of 3, allowable design loads on fiber-cemern siding correlate directly to requved design pressures for Allowable Stress Design, and therefore should be used with combination boding equations for Allowable Stress Design (ASO). By using the combination boding equations for Allowable Stress Design (ASD), the tested allowable design bads for fiber -cement siring ere aligned with the wind speed requirements in ASCE 7- 10 Figure 26.5.1A. Figure 26.5-1B. and Figure 26.5.1C. For this analysis, to calMate the pressures in Tables 3, 4, and 5, the bad combination will be in accordance with ASCE 7.10 Section 2.4 combining nominalloads using allowable shoss design, load combination 7. Load combination 7 uses a load factor of 0.6 applied to the wind velocity pressure. Equation 1, q6=0.00256'K,'Ke'K,"2 Equation; ref. ASCE 7.10 equation 30.3-1) ch , velocity pressure at height z If, , velocity pressure exposure coefficient evaluated at height z Ka , topographic factor w . wind directionality factor V , basic wind speed (3-second gust MPH) as determined from 120151BC, 2017 FBC) Figures 1609.3(1). (2). or (3); ASCE 7-10 Figures 26.5-1& B. or C V-V' fref. 20151BC d 2017 FBC Section 1602.1 derrndrons) V,a , ultimate design wind speeds (3-second gust MPH) determined from 120151BC, 2017 FBC) Figures 1609.3(1). (2), or (3); ASCE 7-10 Figures 26.5.1A• B, or C Equallon 3, p=q,'(GC-GC,) /ref. ASCE 7-10 equation 30.6-1) GC, , product of external pressure coeffick" and gust-elfed factor GC, , product of internal pressure coefficient and gust -effect Tailor p , design pressure (PSF) for siding (allowable desgn bad for siding) To determine design pressure, substitute q, into Equation 3 Equation 4, p=0.00256'K,'Ke'w'VJ''(GCr-GC0) Allowable Stress Design, ASCE 7-10 Section 2.4.1, load combinebw 7 Equation 6, 0.61) • 0.6W fief ASCE 7-10 section 2.4 1, bad combination 7) D , dead load W , wind load To determine the Allowable Stress Design Pressure, apply the load factor for W (wind) from Equation 4 to p (design pressure) determined from equation 4 Equation 6, p.r - 0.61p) Equation 7, p„e a 0.6'10.00256'K,'Kn'Ka'V,e7'(GC,.GCO)) Equation 7 is used to populate Table 3, 4, and 5. To determine the allowable ultimate bask wind speed for Hardie Siding in Table 6, solve Equation 7 for V.. Equation k VA , (p„V.6'0.00256'K,'K,'Ka'(GC-GC,,))as Applicable to methods specified in Exceptions 1 through 3 of (20151BC, 2017 FBC) Section 1609.1.1., to determine the allowable nominal design wind speed (Vasil) for Hardie Siding in Table 6, apply the conversion formula below, Equation 9, V.W = V. • (0.6)eb (ref 2015 IBC 6 2017 FBC Section 1609.3.1) V.w , Nominal design wind speed (3-second gust mph) (ref. 201519C tt 2017 FBC Se" Table 2• Coefficients and Constantsarsed in Determining V and p, d1' 141` :0 GA WA a/ wv• L t r , STA F .5 %' RONALD I. OGAWA ASSOCIATES, INC 16835 ALGONQUIN STREET 4443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686.17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshordie.com Table 3, Allowablo Stress Design . Component and Cladding (CbC) Pressures (PSF) to be Resisted at Various Wind Speeds . Wind Exposure Category B, Wind Speed 3-secondgust) 100 105 110 115 120 130 140 150 160 170 180 190 200 210 Heigh (III B B B B B B B B B B B B B B 0.15 14.4 15.9 17.5 19.1 20.8 24A 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 20 14.4 15.9 17.5 191 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 25 14.4 15.9 17.5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 46.6 52.1 57.8 63.7 30 14.4 15.9 17.5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 35 15.1 16.6 18.2 19.9 21.7 25.4 29.5 33.9 38.6 43.5 48.8 54.4 W.2 66.4 40 1 -15.7 1 -17.3 19.0 20.7 22.6 26.5 30.7 35.3 40.1 5.3 50.8 56.6 62.7 69.1 45 1 -16.2 1 .17.9 19.6 1.21.4 23.3 27.4 31.7 36.4 41.5 46.8 52.5 58.5 64.8 71.4 50 16.7 18.4 20.2 22.1 24.1 28.2 32.7 37.6 42.8 48.3 54.1 60.3 66.6 73.7 55 17.1 18.9 20.7 22.6 24.7 28.9 33.6 38.5 43.8 49.5 55.5 61.8 68.5 75.5 1 1 . 100 25.6 28.2 31.0 33.8 36.9 3.3 502 57 6 65.5 74.0 82.9 92.4 1024 1129 Table 4, Allowable Stress Design - Component and Cladding (CbC) Pressures (PSF) to be Resisted at Various Wind Speeds -Wind Exposure Category C, Wind Speed 3-secondgust) IW 105 110 115 120 130 1 140 150 1 160 170 180 190 200 210 Heigh 11 C C C C C C C C C C C C C C 015 17.5 19.3 21.2 1.23.2 25.2 29.6 34.4 39.5 44.9 50.7 56.8 63.3 70.1 77.3 20 18.6 20.6 22.5 24.6 26.7 31.4 36A 41.8 Z7.5 53.7 602 b7.0 74.3 81.9 25 19.4 21.4 23.5 25.6 27.9 32.8 38.0 43.6 49.6 56.0 62.8 70.0 77.6 85.5 30 202 22.3 24.5 26.7 29.1 34.2 39.6 45.5 51.8 58.4 65.5 73.0 80.9 89.2 35 20.8 23.0 25.2 27.6 30.0 35.2 40.8 46.9 53.3 60.2 67.5 75 2 83.3 91.9 40 21.5 23.7 26.0 28.4 30.8 36.3 42.0 48.3 54.9 62.0 69.5 77.4 85.8 94.6 45 22.0 24.2 26.6 29.1 31.6 37.1 43.1 49.4 562 63.5 712 1 -79.3 1 -87.8 1 -95.9 50 22.5 24.8 27.2 29.7 32.4 38.0 57.6 65.0 72.9 81.2 89.9 99.2 55 22.9 25.2 27.7 30.3 33.0 38.7 44.9 51.5 58.5 66.2 74.2 82.7 91.6 101.0 0 1 t 100 32.6 35.9 39.4 3.1 46.9 55.0 63.8 73.3 83.4 94.1 105.5 117.6 130.3 143.6 Table 5. Allowable Stress Design . Component and Cladding (CbC) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category D, Wind Speed 3-secondgust) 100 105 11D 115 120 130 14D 150 160 170 180 19D 200 210 Hai h (11) D D D D D D D D D D D D D D 015 21.7 23.4 25.7 28.1 30.6 35.9 41.6 47.8 54.4 61.4 68.8 76.7 85.0 93.7 20 22.3 24.6 27.0 29.5 32.1 37.7 43.7 50.1 57.0 64A 72.2 80.4 89.1 982 25 23.1 25.5 28.0 30.6 33.3 39.0 45.3 52.0 59.1 66.8 74.9 83.4 92.4 101.9 30 23.9 26.4 29.0 31.6 34.5 40.4 46.9 53.8 61.3 69.2 77.5 86A 95.7 105.5 35 24.5 27.1 29.7 32.5 35.3 41.5 48.1 65.2 62.8 70.9 79.5 88.6 98.2 108.3 4D 25.2 27.7 30.5 33.3 36.2 42.5 49.3 56.6 61.4 72.7 81.5 90.9 100.7 111.0 45 25.7 28.3 31.1 34.0 37.0 43.4 1 -50.3 01.3 65.1 74.2 I -83.2 I -92.7 I -102.1 113.3 50 26.2 28.9 31.7 34.6 37.7 1.3 51.3 58.9 67.1 75.7 84.9 94.6• 104.8 115.5 55 Zb.6 29.3 32.2 352 38.3 45.0 52.2 59.9 68.1 76.9 162 96.1 106.4 117.4 3 , 1 100 37.0 1 -40.8 1 -44.7 48.9 53,2 62.5 1 -72.5 1 -83.2 1 -94.6 105.3 119,3 133.4 147,9 163.0 Tables 3.4. and 5 ere based on ASCE 7-10 and consislent vwlh the 2W5 IBC. 2015 IRC and the 2017 Florida Building Code Rrfa 12 RONALD I. OGAWA ASSOCIATES. INC. 16835 ALGONQUIN STREET S"3 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshordie.com Table 6, Allowable Wind Speed (mph) for HardlePanel Siding (Anety6caf Metho Product Product Thickness inches) Width inches) Fastener Type Fastener Spacing Frame Type Stud SPeong inches) Building Height''' feet) B C D B C D NDeesignLoad f SF) Fxp B Fxp C 6m D K. Ki GC. GC, HardiePanel® 5/16 48 co on 6 2X4 wood Hem - Fir 16 0- 15 186 168 153 144 130 118 49.7 0.7 0.85 1.03 hsSD 1 086 1A DAS 20 186 164 149 144 127 116 49.7 07 0.9 1.05 1 0.85 1.4 Me 25 lea 16D 147 144 124 114 49.7 0.7 0.94 1.12 1 0.85 1.4 0.1e 30 186 157 144 144 121 112 49.7 0.7 D.98 1.15 1 OA5 IA O.ie 35 182 154 142 141 12D 110 49.7 0.73 1.D1 1,19 1 0.a5 1.4 0.18 40 178 152 141 136 118 109 49.7 o.76 1.04 1.22 1 D.85 1.4 0.18 45 176 150 139 136 117 108 9.7 0.716 1.085 72- 1 0.85 1.4 0.18 50 172 149 138 134 115 107 49.7 O.e1 1.D9 127 1 0.85 71.4 0.18 55 17D 147 137 132 114 106 49.7 0.93 1.11 1.29 1 D.95 1.4 0.18 60 168 146 136 13D 113 105 49.7 0.85 1.13 1.31 1 Ea5 1.4 0.10 100 139 124 116 108 96 90 49.7 0.99 129 143 haW 1 0.85 1.8 0.18 HardiePeneW 5/16 48 con d 4 2X4 wood Hem - Fir 16 0. 15 233 212 192 181 164 149 78.7 0.7 055 1.03 hs80 1 M85 IA 0.10 20 233 206 fee 181 159 146 78.7 0.7 0.9 1.09 1 0.85 1.4 0.18 25 233 201 185 181 156 143 707 07 0.94 1.12 1 0.65 1 1.4 0,18 30 233 197 181 181 153 140 78.7 07 D.98 7.16 1 0.65 1.4 0.79 35 229 194 179 177 151 139 78.7 0.73 1.01 1.19 1 0.85 1.4 0,18 40 224 192 177 174 148 137 78.7 0.75 1.04 1.22 1 D.es 71.4 0.18 45 22D 189 175 171 147 136 78.7 0.785 1.95 1245 1 0.85 1.4 0.18 50 217 107 173 168 145 134 78.7 0.01 1.09 1.77 1 0.05 1.4 0.18 55 214 185 172 166 144 133 78.7 D.83 1,11 1.29 1 0.85 1.4 o.1a 60 212 184 171 164 142 132 78.7 0.85 1.13 1.37 1 0.85 1.4 0.18 100 175 155 146 136 120 113 78.7 0.99 1.28 1.43 ha80 1 0.85 1.0 0.18 HardiePanel® 5/16 48 6 2X4 wood Hem - Fir 24 0. 15 147 134 121 114 103 94 31.3 0.7 0.85 1.03 hs80 1 0.85 1.4 0.18 20 147 130 119 114 101 92 31.3 0.7 0.9 1.00 1 0.95 1.4 M18 25 147 127 716 114 98 90 31.3 0.7 0.94 1,12 t 0.85 1.4 0.15 30 147 124 114 114 96 89 31.3 0.7 0.9e 1.16 1 085 1.4 0.18 35 144 123 113 112 95 87 31.3 0.73 1.01 1.19 1 0.85 1.4 0.18 40 141 121 112 109 94 86 31.3 0.76 1.04 122 1 0.86 14 0.18 45 139 119 110 108 92 86 31.3 0.735 1.055 1245 1 O.aS 1.4 0.1e 50 137 11e 106 91 31.3 0.81 1.09 127 1 0.65 1.4 0.18 55 135 117 105 91 31.3 0.83 1.11 1.29 1 0.85 1.4 0.18 60 134 1/6 103 90 31.3 0.85 1.13 1.31 1 0.85 14 0.18 100 111 86 31.3 0.99 1.29 1.43 M60 1 0.S5 1.3 0.18 HardisPeneM 5/ 16 48 CO 6d on 4 2X4 wood Hen - Fir 24 0- 15 182 165 150 141 128 116 47.7 0.7 0.85 1.03 h580 1 0.85 1.4 0.18 20 182 160 146 141 124 113 A7.7 0.7 0.9 TOW t 0.a5 1.4 Fla 25 182 157 144 141 121 111 47.7 07 M94 1.12 1 0.e5 l.4 0.18 30 182 154 141 141 119 109 J7.7 0.7 0.98 1.16 1 0.85 1.4 DAS 35 178 151 139 130 117 108 47.7 0,73 1 M 1,19 1 0.85 1.4 0.1a 40 174 149 138 135 116 107 47.7 0.76 1.04 122 t 0.e5 1A 0,18 45 172 147 136 133 114 106 477 0.785 1,085 1245 1 Des 1.4 0.18 50 169 146 135 131 113 105 47.7 0.81 1.09 1.27 7 O.aS. 1.4 D.1e 55 167 144 134 129 112 UM 47.7 O.e3 1.11 1,29 1 0.95 IA 0.18 60 165 143 133 128 111 103 477 0.85 1.13 31 t 0.e5 74 0.1a 100 137 121 114 105 94 88 47.7 099 125 1.43 Mao 1 0.85 1.8 0.18 HardnePanelf9 5/ 16 48 4d, 0. 091 In. Shank X 0.225 in. HD X 1.5 in. long nvg shank nag 4 edge 8 field 2X4 wood SGx0. 36 16 015 144 131 119 112 101 92 90.0 07 0.1115 Ihs80 t 0.85 1.4 0.1a 20 144 127 116 112 98 90 30.0 0.7 0.9 1 0.e5 7.4 0.18 25 144 124 114 112 96 8B 30.0 0.7 0.94 t 0.85 1 4 0.tB 3D 144 122 112 112 94 87 30.0 0.7 0.98 t 0.85 1.4 0.18 35 141 120 111 109 93 86 30.0 0.73 1.01 11-7245- 1 0. 85 1 4 016 40 138 118 107 92 30.0 0.76 1.D4 1 0.85 14 0.15 45 136 117 105 91 30.0 0.785 1,006 t 0.85 1.4 0.7e 50 134 116 104 89 30.0 0.81 1.09 1 0.85 14 O.te 55 132 114 103 89 30.0 O.a3 t.11 1 O.aS 1.4 0.1660 131 113101883000.115 1.73 1 0.85 1.4 0 100 30. 0 0.99 125 1.49 Mao 1 085 1.8 O to JAMES HARDIE BUILDING PRODUCTS, INC. 1-SM542-7343 info@jsmesherdie.com RONALD I. OGAWA ASSOCIATES. INC. 16835 ALGONOUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 Design Wind, Speed. I Design Wind. Speed. V,a4•11, V.WSa, Appsmhle to me0wds Applicable to methods spee6 In 120751BC, specified In Exceptions 1 2017 FBC) Section through 3 or 120151BC, W9.1.1. as delemnined by 2017 FBC) Section Fptxes 18D9.3(1). (7). or 1609.1.1. 3). Coa fidents usod In Table 6 calculations for D I K. Product Product Thickness Width Fastener Fastener FrameSpacing Stud Building Height" B C D B C D Design 1urines) Type Spacing Type Load ems) urines) feel) PSF) Exp B Exp C Exp D K. 1(4 GC, GCr 0.15 198 180 163 1 163 139 126 1 55 6 07 0.85 1.03 hs80 1 0.85 1.4 0. 88 20 193 175 159 153 135 123 56.6 0.7 0.9 1.08 1 0.85 14 0,18 Min.n. No 8 X Min. No. 25 198 171 157 1 153 132 121 1 58.6 0.7 0.94 1.12 1 0.65 I 1 4 ame 1 . long X 20 ga. 30 198 167 154 1 153 130 119 1 56.8 07 0.95 1.18 1 0.85 IA 0.18 0.323 in 33 mg) X 35 194 165 152 1 150 128 118 58.6 0.73 1.01 1.19 1 0.85 1.4 0.10 HardiePaneW 114 48 head 6 3.625 tin. 16 40 190 162 ISO 147 126 116 56.0 0.76 1.04 1.22 1 0,85 1.4 0.18 diameter X 1.375 45 187 161 148 145 124 115 56.6 0.765 1.065 1.245 1 Fas 1.4 016 ribbed in metal 50 184 159 147 143 123 114 56.6 081 1.09 1.27 1 0.85 1,4 0,18 Du head stud 55 182 157 46 141 122 113 58.6 0.63 1.11 1.29 1 0.85 1.4 0.16 scrcr ew' 60 190 156 145 139 121 112 We 0.85 1.131 1.31 1 0.85 1.4 0.16 1DD 149 132 124 115 102 96 58,6 0,99 126 1.43 h.60 0.85 1.8 0.18 0.15 146 132 120 113 102 93 308 07 0.85 1.03 hs50 1 0.85 1,4 0.10 20 146 128 117 113 99 91 30.8 0.7 0.9 1.08 1 0.85 1.4 O.te Min. No 8 X Min. No. 25 146 126 115 113 97 89 3D.6 0.7 0.94 1.12 1 0.85 1.4 0.18 t in. long X 20 ga. 30 146 123 113 113 95 88 30.6 0.7 D.98 1.76 1 0.85 1.4 0.18 0.323 in 33mv)X 35 143 121 112 110 94 86 300 073 101 1.19 1 0.95 1! 0,18 HardiePanel® 114 48 head 6 3.625 in. 24 40 140 119 110 108 93 85 30.6 078 1,04 1.22 1 0.85 1.4 0.15 diameter X 1.375 45 137 lie 106 91 30.6 0.7e5 1.055 1245 1 0.85 1.4 OAS in metal SO 136 117 1D5 90 30.6 0.81 1.09 1.27 1 OA5 1.4 0.18 bugle head stud 55 134 116 104 90 3D.6 0.83 1.1+ 1,29 1 0.85 1.4 D.15 screw' 60 132 115 102 89 30.6 0.85 1.19 1.31 1 0.55 1.4 0.18 t00 30.8 0.99 1.26 1.43 h-eO 1 0,85 1.8 0.16 0-15 198 180 163 153 139 127 56.7 0.7 0.85 1.03 WO t 0.8S 1.4 0.10 ET&F 20 19e 175 160 153 135 124 56.7 0.7 0.9 1.08 1 0.95 1.4 0.18 0.100 m. Min. No. 25 198 171 157 153 132 121 50.7 0.7 0.94 1.12 1 0.&S 1.4 0.18 knurled 20 ga. 30 198 167 154 153 130 119 56.7 0. 0.98 1.16 1 0,95 1.4 0.18 shank X 33 me) X 35 194 165 152 160 128 118 5&7 0.73 1.01 1.19 t 0.85 t.4 0.18 HardnePane* 5116 48 1.51n. long 4 edge 3.625 in. 16 40 190 163 150 147 126 116 58.7 0.76 1.04 1.22 1 0.l15 1.4 0.18 X 0.25 In. 8 field X 1.375 45 107 161 148 145 124 115 58.7 0.7115 1.055 1,245 1 GAS 1.4 0.18 head in metal 50 184 159 147 143 123 114 5&7 0.31 1.09 1.27 1 0.85 1.4 0.18 diameter stud 55 182 157 146 141 122 113 56.7 0.83 1.11 1.29 1 0.85 1.4 015 pin fastened 60 1BD 156 145 139 121 112 55.7 0.85 1.13 1.3+ 1 0.65 1.4 0.18 100 149 132 124 115 102 96 557 0.99 125 1.43 h>W 1 0,85 1.6 018 0.15 153 139 126 118 107 98 33.7 0.7 0.05 1.03 IuSD t 0,95 1.4 0.18 ET&F 20 153 135 123 118 04 95 337 0.7 0.9 1.06 1 0.85 1.4 0.18 0100 in. Min. No. 25 153 132 121 118 102 94 337 0.7 0.94 1.12 1 0.85 1.4 0.18 knurled 2D ga. 30 153 129 118 lie 100 92 33.7 0.7 0.98 1.10 1 085 1.4 0.18 shank X 33 m0) X 35 150 127 117 116 99 91 337 0.73 1.01 1.19 1 O.&5 1.4 0.16 HerdiePaneW 5/16 48 1.5 in. 1e^9 4 edge 3.625 in. 24 40 147 125 116 114 97 9D 33.7 0.76 1.04 122 1 0.95 1.4 Ole X 0.25 in. 8 field X 1.375 45 144 124 115 112 96 89 33.7 0.785 1.065 1.245 t 0.85 1.4 0.18 headet in metal 50 142 122 113 110 95 Be 33.7 OBI 1.09 1.27 1 0.85 1.4 0.18 diameter stud 55 140 121 113 109 94 87 33.7 0.53 1.11 1.29 1 085 1.4 0.1e pin 60 139 120 112 107 83. 87 337 0.85 1.19 1.31 t 0.85 t.4. 0.1e Taslerne 100 115 89 33.7 1 0.99 1 125 1 0.e5 t 6 0 76 1. Screws shall penetrate the metal framing at least three f1N threads. 2. Knurled shank pins shall penetrate the metal framing at least 114 Inch. 3. Building height a mean roof height (n feel) of a bu0d'ung, except that eave height shall be used for roof angle O less than or equal to 10' (2-12 roof 4. V. a ultimate design wind speed 5. V„4 = nominal design wind speed 6. Linear interpolation of building height is 60 it) and wind speed is permitted 7. Wind speed design assumptions per Analytical Method In ASCE 7-10 Chapter 30 C&C,PeA 1 and Pen 3: Kn=1, K -0.85, GC,-1.4 (hs60). GCr=1 LIMITATIONS OF USE: 1) Fastener pullout must be evaluated when installed a species of wood studs other than that which was tested. 2) In High Velocity Hurricane Zones (HVHZ) install per Weml-Dade County Florida. NOA 17-0406.06 0GAW 7-, WFF AZ 4S/O N 1+ Florida Building Code Online Page 1 of 2 emu,. - kn xrn.r .,r •t•,;?. = c 'fr - '.r tS-tv_7i '"' t_ _ JPMVY 18:.w Yr j)M\ N-'{l,Z C 'Ya' Z'i v _^..+s .Y .: a•fi ci;.[ :, rf 1l.`: .1. Q,. r y ./m ir ..,-.' SS 4' - -• " . - - . '> ftBRir•7718>•a AHIl3D3?1S7 QL'I7L7"DH7?1tc.r .f Li•i -.-A.cY. ,`l;}1::i_3:.: c.,-'J".r-fir :,s1:^.jr_ `=,1.-'LL, .J. DOS Morrie Lop In User RegWration Hot TOPICS Submit Surcharge Stat; & FactS Publicat-O-S Fec Staff Bas Site Map Unks Search Rol 1 1.0 Product Approval USER: Public User C U-- Product Apprctmal Menu > @arch > Application USt > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL12194-R6 Revision 20.17 Approved Aluminum Coils, Inc. 5001 West Knox Street Tampa, FL 33634 813) 249-9743 grahman@aluminumcoilsmc.com Gareth Rahman grahman@aluminumcoilsinc.com Paul Frost 5001 West Knox Street Tampa, FL 33634 813) 249-9742 PFrost@aluminumcoilsinc.com Panel Walls Soffits Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0- Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 06/19/2020 Validated By Locke Bowden L Validation Checklist - Hardcopy Received Certificate of Independence FL12194 R6 COI ALC15001.3 2017 FBC Evaluation Reoort 04 T4 Soffits final.Ddf Referenced Standard and Year (of Standard) Standard AAMA 1402 Equivalence of Product Standards Certified By Sections from the Code Year 2009 hqs://www.floridabuilding.org/pr/pr_app_dtl.aspx?param—wGEVXQwtDquk24AUC%2fE... 2/1 /2018 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products r Method 1 Option D 09/06/2017 09/06/2017 09/13/2017 12/12/2017 1Z/15/2017 FL # Model, Number or Name Description 12194.1 Alumunum Coils Aluminum Soffit Aluminum soffit panels Limits of Use Installation Instructions Approved for use in HVHZ: No FL12194 R6 II ALC15001.3 2017 FBC Evaluation Report Q4 T4 Soffits final.pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: +80/-90 Created by Independent Third Party: Yes Other: See Evaluation Report for limits of use. Evaluation Reports FL12194 R6 AE ALC15001.3 2017 FBC Evaluation Report 04 T4 Soffits final.pdf Created by Independent Third Party: Yes Bade Next Contact Us :: 2601 Blair Sterne Road. Tallahassee FL 32399 Phone: 9SO-487.1824 The State of Florida is an AA/EED employer. Coovrfeht 2007.2013 State of Florida.:: Privacy Statement :: Accessibility Statement •: Refund Statement Under Florida law, email addresses are public records. It you do not want your e-mall address released in response to a public -records request, do not sand electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1). Florida Statutes. effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. It you do not wish to Supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: D cfedk'.Czfd. Safe. https://www. floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquk24AUC%2fE... 2/ 1 /2018 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC 813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 6T" EDITION (2017) Manufacturer: ALUMINUM COILS, INC. Issued September 1, 2017 5001 West Knox Street Tampa, FL 33634 813) 249-9743 www.aluminumcoilsinc.com Manufacturing: Tampa, FL Quality Assurance: PRI Construction Materials Technologies (QUA9110) SCOPE Category: Panel Walls Subcategory: Soffits Code Sections: 1404.5.1, 1709.10 Properties: Wind Resistance REFERENCES Enti Report No. Certified Testing Laboratories (TST1577) CTLA 1847W Standard AAMA 1402 Year 2009 Certified Testing Laboratories (TST1577) CTLA 2076W AAMA 1402 2009 PRI Construction Materials Technologies (TST5878) ACIX-003-02-01 AAMA 1402 2009 PRI Construction Materials Technologies (fST5878) ACIX-003-02-02 AAMA 1402 2009 LIMITATIONS 1. This report is not for use in the HVHZ. 2. Design wind loads shall be determined in accordance with FBC Section 1609. 3. Soffits shall be labeled in accordance with FBC Section 1709.10. 4. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more'restrictive and FBC compliant installation detail shall prevail. 5. Installations shall meet the minimum ventilation requirements of FBC section 1203.2. 6. Field fastener withdrawal may be required by the AHJ for confirmation of existing substrates. All data shall be reviewed by a qualified design professional to•ensure the fastener withdrawal meets or exceeds the minimum load resistance for the project requirements. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. ALC15001.3 FL12194-R6 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. C jj ALUMINUM COILS, INC j1 Soffits RVISM EN TECHNICAL SERVICES, LLC PRODUCT DESCRIPTIONS 3/8" F-Channel Preformed nominal 0.016-inch thick, 3105 H-14 aluminum F-channel. See Appendix D for dimension drawings. 3/8" J-Channel Preformed nominal 0.016-inch thick, 3105 H-14 aluminum J-channel. See Appendix D for dimension drawings. Fascia Preformed nominal 0.019-inch thick, 3105 H-14 aluminum fascia. See Appendix D for dimension drawings. 16" 04 Soffit Preformed nominal 0 0135-inch thick, 3105 H-14 aluminum soffit Panels provided in 16- inch sections. The reported net free ventilation areas are 22.3 in /lin.ft for the 'full vent' configuration and 11.1 inZ/lin.ft and for the 'center vent' configuration. See Appendix D for dimension drawings. 12" T4 Soffit Preformed nominal 0.0135-inch thick, 3105 H-14 aluminum soffit P,anels provided in 12- inch sections. The reported net free ventilation areas are 12.5 in /lin.ft for the 'full vent' configuration and 4.2 inZ/lin.ft for the 'center vent' configuration. See Appendix D for dimension drawings. ALC15001.3 FL12194-R6 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT ALUMINUM COILS, INC Soffits The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 60 Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. R. 1,Q•'',CEN`SF•'' No 74021 13•' 'STATE OF •UJ O •• off O R `•O ON A, `e 4 • CERTIFICATION OF INDEPENDENCE 2017.09.01 10-:06:18 04f001 Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A —Approved Systems (8 pages): 2) APPENDIX B — Installation Drawings (12 pages) 3) APPENDIX C — Design Wind Loads(4 pages) 4) APPENDIX D — Dimension Drawings (4 pages) ALC15001 3 FL12194-R6 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC APPROVED SYSTEMS ALUMINUM COILS, INC Soffits Appendix A The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressures (MDP) were calculated using a 1.5:1 margin of safety per FBC Section 1404.5.1. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on -center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system. 5. Unless otherwise specified, the Wood substrate shall be minimum No. 2 SPF (S.G. = 0.42) 2x lumber. Substrate attachment shall be designed by others in accordance with FBC requirements to meet the minimum design requirements for the project. 6. Unless otherwise specified, the Masonry substrate shall conform to ASTM C 90. Substrate attachment shall be designed by others in accordance with FBC requirements to meet the minimum design requirements for the project. 7. Typical fastening details are as follows: a. 12' T4 Soffit —12-inch o.c. Fastener Fastener Location Location 1 b. 12' T4 Soffit — 4-inch o.c. Fastener Fastener Fastener Fastener Location Location 4 Location Location c. 16' Q4 Soffit —16-inch o.c. Fastener Fastener Location Location ALC15001.3 FL12194-R6 Page 1 of 8 This evaluation report is provided for Slate of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC d. 16" 04 Soffit — 8-inch o.c. Fastener Location 11- Fastener Fastener Location l ALUMINUM COILS, INC Soffits Approved System Numbers and Definitions 12F-# Approved Systems for 12-inch Overhang with F-Channel 12J4 Approved Systems for 12-inch Overhang with J-Channel 16F-# Approved Systems for 16-inch Overhang with F-Channel ' 16J4 Approved Systems for 16-inch Overhang with J-Channel 24F-# Approved Systems for 24-inch Overhang with F-Channel 24J-# Approved Systems for 24-inch Overhang with J-Channel Apobndix A Approved Systems for 12-inch overhang with F-Channel Wall Connection Eave Connection, System Panel MOP No. Width pso Substrate F-Channel Substrate Panel Attachment Fascia Cap Attachment Attachment Max. One (1) min. 3/8-inch head dia. nail, One (1) min. 3/8 x 3/8-inch One (1) min. 1 3/4-inch long x 0072-inch dia. x min. 3/16- 12F-1 16-inch Wood min. 1.25-inch embedment spaced Wood crown staple spaced 16-inch inch head dia. trim nail t40.0 24-inch o.c. O.C. spaced 36-inch o.c. Max. Three (3) min. 3/4-inch x 1/4-inch One (1) min 3/4-inch:x 1/4-inch One min. 1 3/4-inch long x 0.072-inch dia. x min. 1/4-inch 48 12F-2 16-inch Wood crown staples in diamond pattern Wood crown staple spaced 8-inch o.c. head dia. trip nail spaced 48- 64.2 spaced 24-inch o.c. and securing each panel lap inch o.c. One (1) min 3/4-inch x 1/4-inch One (1) min. 1 3/4-inch long x 12F-3 Max. Masonry One (1) 14 ga. 5/8-inch long T nail Wood crown staple spaced 8-inch o.c. 0.072-inch dia. x min. 1/4-inch 48 16-inch spaced 8-inch o.c. and securing each panel lap head dia. trip nail spaced 48- 64.2 inch o.c. ALC15001.3 FL12194-116 Page 2 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 12-inch overhang with J-Channel Wall Connection Eave Connection System Panel MDP No. Width psf) Substrate F-Channel _ Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment Three (3) min. 3/4- inch x 1/4-inch crown One (1) min. #8 x 1/2-inch One (1) min 3/4-inch x One (1) min. 1 3/4-inch long x 12J-1 Max. Wood staples In diamond long x 3/8-inch head diameter Wood 1/4-inch crown staple 0.072-inch dia. x min. 1/4-inch 48 16-inch pattern spaced 24- screw spaced 16-inch o.c. spaced 8-inch o.c. head dia. trip nail spaced 48- 64.2 inch o.c. connecting soffit to J-channel inch o.c. Approved Systems for 16-inch overhang with F-Channel s3; Wall Connection Eave Connection System Panel MDP No. Width psf) Substrate F-Channel Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga. 1/4-inch crown x One (1) min. 1.75-inch x 16F-1 Max. Masonry One (1) 14 ga. 5/8-inch long T nail Wood 1-inch leg staple spaced max. 0.072-inch diameter finishing nail with min. 3/16- t53.3 12-inch spaced max. 8-inch o.c. 4-inch o.c. and securing each inch head spaced panel lap 12-inch o.c. One (1) 18 ga. 1/4-inch crown x One (1) min. 1.75-inch x Max. Three (3) 18 ga. 1/4-inch crown x 1- 1-inch leg staple spaced max.' 0.072-inch diameter 16F-2 12-inch Wood Inch leg staples in diamond pattern Wood 4-inch o.c. and securing each finishing nail with min. 3/16- 153.3 spaced 16-inch o.c. panel lap inch head spaced 12-inch o.c. Max. One (1) 3/8-inchhead dia: nail, min. One (1) min 3/8-inch x 3/8-inch One (1) min. 1 3/4-inch long x 0072 inch diax min 16F- 3 16- inch Wood 1.25-inch embedment spaced 24- Wood crown staple spaced 16-inch 3/ 16-inch head dia. trim nail t25. 6 inch o.c. O.C. spaced 36-inch o.c. Three ( 3) min. 3/4-inch x 1/4-inch One (1) min. 1 3/4-inch long 16F- 4 Max' Wood crown staples in diamond pattern Wood One ( 1) min 3/4-inch x 1/4-inch x 0.072-inch dia. x min. 1/4- 27 16- inch spaced 24-inch o.c. crown staple spaced 8-inch o.c. inch head dia. trip nail 36.1 spaced 48-inch o.c. ALC15001. 3 FL12194-R6 Page 3 of 8 This evaluation report is provided for Slate of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 16-inch overhang with F-Channel Wall Connection Eave Connection System Panel MDP No. Width pso Substrate F-Channel Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga. 1/4-inch crown x One (1) min. 1.75-inch x 0.072-inch diameter 16F-5 Max. Masonry One (1) 14 ga. 5/8-inch long T nail Wood 1-inch leg staple spaced 4-inch finishing nail with min. 3/16- t43.3 16 inch spaced 8 inch o.c. o.c. and securing each panel inch head spaced lap 16-inch o.c. Three (3) 18 ga.1/4-inch crown x 1- One (1) 18 ga. 1/4-inch crown x One (1) min. 1.75-inch x 0.072-inch diameter 16F-6 Max. 16 inch Wood inch leg staples in diamond patlem Wood 1o. ch leg staple spaced panelo.c. and securing each panel finishing nail with min. 3/16- t43.3 spaced 16-inch o.c. inch head spaced 164nch o.c. Approved Systems for 16-inch overhang with J-Channel Wall Connection Eave Connection System Panel MDP No. Width pso Substrate J-Channel Substrate Panel Attachment Fascia Cap Attachment Attachment Max. Three (3) min. 3/4-inch x•1/4-inch One (1) min 3/4-inch x 1/4-inch One (1) min. 1 3/4-inch long x 0.0724nch dia. x 23.5 16J-1 16-inch Wood crown staples in diamond pattern Wood crown staple spaced 8-inch o.c. min. 1/4-inch head dia. trip 31.4 spaced 24-inch o.c. nail spaced 48-inch o.c. ALC15001.3 FL12194-R6 Page 4 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i CREEK TECHNICAL SERVICES. LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 24-inch overhang with F-Channel Wall Connection Center Connection Eave Connection System Panel MDP No. Width pso Substrate F-Channel Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga.1/4-inch Nominal 1x2 crown x 1-inch leg No.2 SYP staple spaced Three (3) 18 ga.1/4- anchored to 12-inch o.c. securing One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max inch crown x 1-inch rafter with one each panel lap inch crown x 1-inch 0.072-inch diameter 24F-1 12 inch Wood leg staples in 1) min. 2.25- Wood leg staple spaced 8- finishing nail with min. 801-90 diamond pattern inch x 7d ring One (1) min. 1.75-inch inch o.c. 3116-inch head spaced spaced 16-Inch o.c. shank nail x 0.072-inch diameter 12-inch o.c. 24-inch o.c. finishing nail with min. 3/16-inch head spaced 4-inch o.c. One (1) 18 ga.1/4-inch crown x 1-inch leg Nominal 1x2 staple spaced One (1) min. 1.5- No.2 SYP 12-inch o.c. securing One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max. inch x 11 ga. anchored to each panel lap inch crown x 1-inch 0.072-inch diameter 801 24F-2 12-inch Wood smooth shank rafter with one Wood leg staple spaced 8- firfishing nail with min. 76.6 roofing nail spaced 1) 7d x 2.25- One (1) min. 1.75-inch inch o.c. 3(16-inch head spaced 16-inch o.c. inch ring shank x 0.072-inch diameter 12-inch o.c. nail 24-inch o.c. finishing nail with min. 3/16-inch head spaced 4-inch o.c. One (1) 18 ga.1/4-inch crown x 1-inch leg Nominal 1x2 staple spaced No.2 SYP 12-inch o.c. securing One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max. One (1) 14 ga. 5/8- anchored to each panel lap inch crown x 1-inch 0.072-inch diameter 80/ 24F-3 12-Inch Masonry inch long T nail rafter with one Wood leg staple spaced 8 finishing nail with min. 76.6 spaced 8-inch o.c. 1) 7d x 2.25- One (1) min. 1.75-inch inch o.c. 3/16-inch head spaced inch ring thank x 0.072-inch diameter 12-inch o.c. nail 24-inch o.c. finishing nail with min. 3/16-inch head spaced 4-inch o.c. ALC15001.3 FL12194-R6 Page 5 of 8 This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. - CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 244nch overhang with F-Channel Wall Connection Center Connection Eave Connection System Panel MOP No. Width pSD Substrate F-Channel, . Attachment Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment One (1) 18 ga. 1/4-inch crown x 1-Inch leg Nominal 1x2 staple securing the No.2 SYP nailer of each female Three (3) 18 ga.1/4- anchored to lock or spaced One (1) 18 ga. 1/4- Ohe (1) min. 1.75-inch x Max. Inch crown x 1-inch rafter with one 16-inch o.c. securing inch crown x 1-inch 0.072-inch diameter 24F-4 16-inch Wood leg staples in 1) min. 2.25- each panel lap Wood leg staple spaced 8- finishing nail with min. 801-60 diamond pattern inch x 7d ring inch o.c. and securing 3/16-inch head spaced spaced 16-inch o.c. shank nail One (1) min. 1.75-inch each panel lap 16-inch o.c. 24-inch o.c. x 0.072-inch diameter finishing nail with min. 3/16-inch head spaced 4-inch o.c. One (1) 18 ga. 1/4-inch crown x 1-inch leg staple securing the Nominal 1x2 nailer of each female One (1) min. 1.5- No.2 SYP lock or spaced One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max. inch x 11 ga. anchored to 16-Inch o.c. securing inch crown x 1-inch 9.072-inch diameter 24F-5 Wood smooth shank rafter with one each panel lap Wood leg staple spaced 8- finishing nail with min. 80/-60 16-inch roofing nail spaced 1) 7d x 2.25- inch o.c. and securing 3/16-inch head spaced 16-inch o.c. inch ring shank One (1) min. 1.75-inch each panel lap 16-inch o.c. nail 24-inch o.c. x 0.072-inch diameter finishing nail with min. 3/16-inch head spaced 4-inch o.c. ALC15001.3 FL12194-R6 Page 6 of 8 This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appdndix A Approved Systems for 24-inch overhang with F-Channel Wall Connection Center Connection Eave"Connection System Panel MDP No. Width pst) Substrate F-Channel Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga. 1/4-inch crown x 1-inch leg staple securing the Nominal 1x2 nailer of each female No.2 SYP lock or spaced One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max. One (1) 14 ga. 5/8- anchored to 16-inch o.c. securing inch crown x 1-inch 0.072-inch diameter 24F-6 16-inch Masonry inch long T nail rafter with one each panel lap Wood leg staple spaced 8- finishing nail with min. 801-60 spaced 8-inch o.c. 1) 7d x 2.25- inch o.c. and securing 3/16-inch head spaced inch ring shank One (1) min. 1.75-inch each panel lap 16-inch o.c. nail 24-inch o.c. x 0.072-inch diameter finishing nail with min. 3/16-inch head spaced 4-inch o.c. ALC15001.3 FL12194-R6 Page 7 of 8 This evaluation report is provided I& Stale of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 24-inch overhang with J-Channel Wall Connection . Center Connection Eave Connection System Panel MDP No. Width pso Batten J-Channel Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment Nominal 1x2 No.2 SYP scabbed between rafters with One (1) 18 ga.1/4- one (1) min. 2.25- inch crown x 1-inch Nominal 1x2 inch x 7d ring shank leg staple spaced No.2 SYP Three (3) 18 nail straight -nailed 12-inch o.c. anchored to ga.1/4-inch crown through the rafter securing each panel One (1) 18 ga. , - One (1) min. 1.75-inch Max. rafter with one x 1-inch leg into the end of the lap inch crown x 1-inch x 0.072-inch diameter 24J-1 12-inch 1) min. 2.25 staples in diamond batten or two (2) Wood leg staple spaced finishing nail with min. t60 inch x 7d ring pattern spaced 16- min. 2.25-inch x 7d One (1) min. i nch- 8-inch o.c. 3/16-inch head spaced shank nailshankkailo.c inch o.c. hankringshank nails toe- inch x 0.072-inch 12-inch o.c. n nailed on either side diameter finishing of the batten at nail with min. 3/16- each batten/rafter inch head spaced intersection. Max. 4-inch o.c. rafter spacing is 24-inch o.c. . Nominal 1x2 No.2 SYP scabbed One (1) 18 ga.1/4- between rafters with inch crown x 1-inch one (1) min. 2.25- leg staple securing Nominal 1x2 inch x 7d ring shank the nailer of each No.2 SYP Three (3) 18 nail straight -nailed female lock or One (1) 18 ga.'/. anchored to ga.t/4-inch crown through the rafter spaced 16-inch o.c. inch crown x 1-inch One (1) min. 1.75-inch Max. rafter with one x 1-inch leg into the end of the securing each panel leg staple spaced x 0.072-inch diameter 24J-2 16-inch 1) min. 2.25- staples in diamond batten or two (2) lap Wood 8-inch o.c. and finishing nail with min. 153.3 inch x 7d ringg pattern spaced 16- min. 2.25-inch x 7d securingeach panel 3/16-inch head spaced shank nail inch o.c. ring shank nails toe- One (1) min. 1.75- lap 16-inch o.c. 24-inch o.c. nailed on either side inch x 0.072-inch of the batten at diameter finishing each batlen/rafler nail with min. 3/16- intersection. Max. Inch head spaced rafter spacing is 4-inch o.c. 24-inch o.c. ALC15001.3 FL12194-R6 Page 8 of 8 This evaluation report is provided for Slate of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B INSTALLATION Note - Refer to the APPROVED SYSTEMS section of this report for additional installation details of a selected system and maximum design pressures limitations. No. I Installation Detail Min. ;/8• hand din. nail with min, LU" engagement (for'iwoo9 'subetrate/ .6r min. 0..00" din. T-nail or stub nail with mtn. 5/8' engagement(for concrete ov block oubstrate),, spaced as noted above. ASCIA SLIP BOARD ASCIA TRIM 12F-1 & \— SOFFIT (OVERHANG WIDTH VARIES) 12F-3\_.F" CHANNEL wood. concu•era or Block N FASCIA LIP 1 /4" STAPLE -SOFFIT TO ASCIA BOARD #T50 8" X 3/8" STAPLE 16" O.C. LPAINTED S.S. 1 3/4" TRIM NAIL MIN. 5 NAILS PER' 12' PIECE SOFFIT & FASCIA DETAIL ALC15001.3 FL12194-R6 Page 1 of 12 This evaluation report is provided for Slate of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail 3/ IMM ``t SOFFIT STAPLE OPEN RAPIER 3/4' X' 1/4' ' DIAMOND PATTERN DETAILCROWNSTAPLES USING A DIAMOND 3i0• Krvt01/ srs PATTERN FACIA BOARD \ i FASCIA CAP 12F-2 3/4' X 1/4" CROWN FACIA BOARD A" 1-3/4' TRIM NAIL STAPLE ON CENTER 1-3/4- TRIM NAIL PAINTED S.S. CHANNEL CAN BE PAINTED S.S. 48` FASCIA CAPINSTALLEDWITHTHEQ.C. NAILING FLANGE UP OR 3/4' X 1/4' DOWN CROWN STAPLE SOFFIT -max•. 12=inch apan WOOD SOFFIT SUBSTRATE SOFFIT &FASCIA DETAIL ALC15001.3 FL12194-R6 Page 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Apl endix B System No. Installation Detail OPEN RAFTER s SOFFIT STAPLE 0' DIAMOND DETAILE11. PATTERN FACIA BOARD Kr„Mr„ rwus i 3/4- X 1/4- CROWN STAPLE '24' e ON CENTER USING A DIAMOND PATTERN FASCIA CAP 12J-1 L—CHANNEL 3/4' X 1/4- CROWN 8' 1-3/4- TRIM NAIL FACIA 80ARD 1-3/4- TRIM NAIL STAPLE ON CENTER. PAINTED S.S. Gcrewed to soffit with one(l) Rex PAINTED S.S. 48" FASCIA CAP 1/21- x 3/6*. head diameter screw, O.C. 3/4' X 1/4' 16• O.C. CROWN STAPLE SOFFIT —max. 12-inch span SOFFIT WOOD OR BLOCK SOFFIT & FASCIA SUBSTRATE DETAIL ALC15001.3 FL12194-R6 Page 3 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Sofflts Appibndix B System No. Installation Detail I I- TRIM NAIL FASCIA BOARD PAINTEU S'S*---\ FASCIA CAP SOfHT CROWN STAPLE OPEC! RAFTER FASCIA BOARD N CA S/B' I•Hdl 16F-1 SOFFIT & FASCIA 16F-5 DETAIL FASCIA CAP; REFER TO SOFFIT L FASCIA DETAIL f' CNANIlEL SOFFIT; MAX. 16' SPAN MASONRY SUBSTRATE ALC15001.3 FL12194-R6 Page 4 of 12 This evaluation report is provided for Slate of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC System No. I Installation Detail , M'in. 3/0• head die, nail with mitt., 11,40 enc)dgement(for wood suhattate) Ci-' min. 0.097" dia. T-trail. or stub nail with min. 5/q" engaggment(for concrete or Block substrate), spaced aa'noted above. FASCIA SLIP BOARD FASCIA TRIM , SOFFIT (OVERHANG WIDTH VARIES) 16F-3 F" CHANNEL Wood,. Conc-- or Block W FASCIA LIP 1 /4" STAPLE SOFFIT TO ASCIA BOARD #T50 8" X 3/8" STAPLE 16" O.C. L-PAINTED S.S. 1 ,3/4" TRIM NAIL, MIN. 5 NAILS PER 12' PIECE SOFFIT & FASCIA DETAIL i ALUMINUM COILS, INC Soffits Appendix B ALC15001.3 FL12194-R6 Page 5 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail SOFFIT STAPLE OPEN RAFTER 3/a• x 1/a' 1 t DIAMOND PATTERN LUSINCCROWNsAItst, A O are• xTvto/ sr.s PATTERN FACIA BOARD FASCIA CAP 16F-4 3/4• X 1/4' CROWNJTRIMMLFACIA BOARD 8" 1 STAPLE ON CENTER PF' 1-3/4' TRIM NAIL CHANNEL CAN BE PAINTED S.S. 48" INSTALLED CAP WITH THE, O.C' FASCUI NAILING FLANGE UP OR 3/4" X 1/4" DOWN CROWN STAPLE SOFFR—max. 16-iitich span WOODS SUBSTRATE SOFFIT & FASCIA DETAIL ALC15001.3 FL12194-R6 Page 6 of 12 This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail 1 TRIM NAIL FASCIA BOARD PAIHTEU S.S. FASCIA CAP SOFFIT Ys1- CROWN STAPLE OPEII RAFTER FASCIA BOARD Yl' CROWN STAPLES SOFFIT 8 FASCIA USOIG A DIAMOND 16F-2 $i PATTERN: REFER TO DETAIL SOFFIT STAPLE 16F-6 DIAMOND PATTERN / DETAIL FASCIA CAP; REFER / \ TO SOFFIT 1 FASCIA f' CHANNEL BE FAR. SOFFIT. MAX. 16- SPAN W\ / SUBSTRATE SOFFIT STAPLE DIAMOND PATTERN ALC15001.3 FL12194-R6 Page 7 of 12 This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 16J-1 CREEK TECHNICAL SERVICES, LLC No. I Installation Detail OPEN RAFTER X 1/4' CROWN STAPLE '24' CENTER USINGA DIAMOND PATTERN ALUMINUM COILS, INC Soffits Appendix B I ;> UM \\ SOFFIT STAPLE L IDIAMOND PATTERN DETAILFACIA BOARD % _3/1, KT/ AfTIV Li / ASCIA CAP 3/ 4" X 1 /4' CROWN FACIA BOARD STAPLE " 8" ON CENTER 1-3/4' TRIM NAIL CHANNEL 1-3/j' TRIM NAUL PAINTED S.S, PAINTED S.S. 48 FASCIA CAP O. C. 6_3/4" X 1/4` CROWN STAPLE WOOD OR BLOCK SUBSTRATE SOFFIT — max. 16-inch span SOFFIT & FASCIA DETAIL ALC15001. 3 FL12194-R6 Page 8 of 12 This evaluation report is provided for Stale of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail 1 I- TRW NAIL FASCIA BOARD PAINTED S.S. 1'et- CROWtf FASCIA CAP STAPLES SOFFIT USING A DIAMOND PATTERN; REFER TO 1-rt- CROWN STAPLE SOFFIT STAPLE OIAMONO PATTERN DETAIL 1 I- TRIM NAIL FASCIA BOARD PANTED S.S. SOFFIT 8 FASCIA 24F-1 & DETAIL 24F4 1-4- CROW1 STAPLE FASCIA CAPi REFER TO SOFFIT i FASCIA / OETA0. 9+ Nominal SYP Batten Anchored to SOFFIT; MAX. 24' F•CHAIBIEL Rafters with one Id Ring Shank Noll of I every Rafter / WOOD SUBSTRATE \ / SOFFIT STAPLE DIAMOND PATTERN ALC15001.3 FL12194-R6 Page 9 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installPtion, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail 1 i' TR01 NAIL FASCIA BOARD PAINTED S.S. 14" SMOOTH SHANK FASCIA CAP ROOF NAILS SOFfli 1* 4" CROWN STAPLE et1 t' TRIM NAO. FASCIA BOARD A*",, S.S SOFFIT & FASCIA 24F- 2 & DETAIL 24 F-5' 1' 4' CROWN STAPLE FASCIA CAP; REFER f0 SOFFIT 1 FASCIA DETAIL Noannal 1'12' SYP Batten Anckered to SOFFITi MAX. 24' F- CHANNEL Rafters with one Id Ring Shank 1044 at every Rafter WO00 SUBSTRATE ALC15OO1. 3 FL12194-R6 Page 10 of 12 This evaluation report is provided for Slate of Florida product approval under Rule 61G2O-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appdndix IS System No. Installation Detail 1 t• TRIM NAIL FASCIA BOARO PAINTED S.S. tsOA i' i-IIA4S FASCIA CAP SOFFIT r4* CROWN STAPLE 1 TRIM RAIL FASCIA BOARD PAINTEO S.S. SOFFIT & FASCIA DETAIL 24F-3 & 24F-6 r.t• CROWN STAPLE FASEIA CAPS REFS' TO SOFFIT & FASCIA DETAIL Nominal 1'a7' SYP Batten Anchored to SOFFIT. MAX, tl' F-CHANNEL Rallers with an* 7d Ring Shanh Nail at every Ratter MASONRY ALC15001.3 FL12194-R6 Page 11 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail 1 t• TROT NAIL FASCIA BOARD PAINTED S.S. 1'Q' (Rows FASCIA CAP STAPLES SOFFIT USING A DIAMOND PATTERN; REFER To CANTIMEREO I'ri- CROWN STAPLE SOFFIT STAPLE RAFTER OtANOND PATTERN DETAIL FASCIA BOARD SOFFIT & FASCIA I t' IRln NAIL DETAIL 24J" PAINTED S.S. rvi" CROWN STAPLE 24J-2 r — FASCIA CAP; REFER \ TO SOFFlT t FASCIA DETAIL / Nominal 1' a T SYP battens, \ nabbed between'rslters and 30FFlT; MA%: 2s' r 3/81 1-CHANNEL secured wllh one (1) 7d ring I I) shank nall sbatght-naPed thtough the rafter Into the and WOOD SUBSTRATE - of the batten or Iwo (2) Td / dng sow* nags toe•nalled an elther side of the battern at the battenhalla the SOFFIT STAPLE DIAMOND PATTERN ALC15001.3 FL12194-R6 Page 12 of 12 This evaluation report is provided for Slate of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC DESIGN WIND LOADS ALUMINUM COILS, INC Soffits Appendix C The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-10 under the following provisions: 1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC. 2. Exposure B, C, and D shall be as defined in section 1609 of the FBC. 3. Design wind loads are provided only for walls/soffits with a mean roof height less than or equal to 60-ft. 4. All calculations are based on an effective wind area of 10-ft2 or less. 5. Topographic factors such as escarpments or hills have.been excluded from the analysis. 6. Wind directionality factor, Kd = 0.85 7. Vd, is shown in the tables below. Design pressures are multiplied by 0.6 in accordance with Section 1609.1.3 of the FBC. 8. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional. 9. Zones 4 and 5 shall be defined as shown below. Dimension 'a' shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever is smaller, but not less than either 4% of the least horizontal dimension or 3-ft. ALC15001.3 FL12194-R6 Page 1 of 4 This evaluation report is provided for Stale of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, inslallaiion, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix C x" :,.•, 'y„w,'_:_f+`-` b_ esf`-ri;W_m_dtP,es`sures`fOfaSoffitsin'Ez osti e Bi'.•, .,_ r _ _ Bulldlrigis' +r SType:; ti•-•.a Zone:f n; MWitilghc ft 11 FORWiwiNMI Bas_ictW%ri_c1fS' e_ecl m 1'20 1:30. 1.40 1 5U' r 160• 1;7,0 180 ' 1'90 r t- ,Rcl 200 Enclosed 4 20 16.9 19.8 22.9 26.3 30.0 33.8 37.9 42.2 46.8 25 16.9 19.8 22.9 26.3 30.0 33.8 37.9 42.2 46.8 30 16.9 19.8 22.9 26.3 30.0 33.8 37.9 42.2 46.8 40 18.3 21.5 24.9 28.6 32.5 36.7 41.2 45.9 50.8 50 19.5 22.9 26.5 30.5 34.7 39.1 43.9 48.9 54.1 60 20.5 24.0 27.8 32.0 36.4 41.1 46.0 51.3 56.8 Negative Loads) 5 20 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 25 20.8 24.4 28.3 32.5 37.0 41.7 46.8 ' 52.1 57.8 30 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 40 22.6 26.5 30.7 35.3 40.1 45.3 50.8 56.6 62.7 50 24.1 28.2 32.8 37.6 42.8 48.3 54.1 60.3 66.8 60 25.3 29.6 34.4 39.5 44.9 50.7 56.8 63.3 70.1 Enclosed 4 20 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 25 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 30 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 40 11.7 13.8 16.0 18.3 20.8 23.5 26.4 29.4 32.5 50 12.5 14.7 17.0 19.5 22.2 25.1 28.1 31.3 34.7 60 13.1 15.4 17.8 20.5 23.3 26.3 29.5 32.9 36.4 Positive Loads) 5 20 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27A 30.0 25 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 30 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 40 11.7 13.8 16.0 18.3 20.8 23.5 26.4 29.4 32.5 50 12.5 14.7 17.0 19.5 22.2 25.1 28.1 31.3 34.7 60 13.1 15.4 17.8 20.5 23.3 26.3 29.5 32.9 36.4 ALC15001.3 FL12194-136 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix C r--'; -+•F ` x`1.'• pesi' n,VlliridP•:Lessutesifo'r"Soffts'in,Eicposuie;C j.`.- Buildlri c'(iJ,x.=Zorie• r" k s : sM n Roofs r11'e ht ft ry t ' .r.stBasic:Wirid3S `eed: m Fi a te r°' r$s?WWX%:, 120 30 s . 140 150 aY 160 170 1'80 x: ?m' f a 190r a 200' AA`:r:w%` 20 21.7 25.4 29.5 33.8 38.5 43.5 48.7 54.3 60.2 Enclosed 4 25 22.6 26.6 30.8 35.4 40.2 45.4 50.9 56.7 62.8 30 23.6 27.7 32.1 36.9 41.9 47.3 53.1 59.1 65.5 40 25.0 29.4 34.1 39.1 44.5 1 -50.2 56.3 62.7 69.5 50 26.2 30.8 35.7 41.0 46.6 52.6 59.0 65.8 72.9 60 27.2 31.9 37.0 42.5 48.3 54.6 61.2 68.2 75.5 Negative Loads) 5 20 26.7 31.4 36.4 41.8 47.5 53.7 60.2 67.0 74.3 25 27.9 32.8 38.0 43.6 49.6 56.0 62.8 70.0 77.6 30 29.1 34.2 39.6 45.5 51.8 58.4 65.5 73.0 80.9 40 30.9 36.3 42.1 48.3 54.9 62.0 69.5 77.5 85.8 50 32.4 38.0 44.1 50.6 57.6 65.0 72.9 81.2 89.9 60 33.6 39.4 45.7 52.5 59.7 67.4 75.5 84.2 93.2 20 13.9 16.3 18.9 21.7 24.7 27.9 31.2 34.8 38.5 Enclosed 4 25 14.5 17.0 19.7 22.6 25.8 29.1 32.6 36.3 40.3 30 15.1 17.7 20.6 23.6 26.9 30.3 34.0 37.9 42.0 40 16.0 18.8 21.8 25.1 28.5 32.2 36.1 40.2 44.5 50 16.8 19.7 22.9 26.3 29.9 33.7 37.8 42.1 46.7 60 17.4 20.5 23.7 27.2 31.0 35.0 39.2 43.7 48.4 Positive Loads) 5 20 13.9 16.3 18.9 21.7 24.7 27.9 31.2 34.8 38.5 25 14.5 17.0 19.7 22.6 25.8 29.1 32.6 36.3 40.3 30 15.1 17.7 20.6 23.6 26.9 30.3 34.0 37.9 42.0 40 16.0 18.8 21.8 25.1 28.5 32.2 36.1 40.2 44.5 50 16.8 19.7 22.9 26.3 29.9 33.7 37.8 42.1 46.7 60 17.4 20.5 23.7 27.2 31.0 35.0 39.2 43.7 48.4 ALC15001.3 FL12194-R6 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix C r;`r;;,•'s':;-?':;!tf i i`'k D_e`si'_n'W1rid;P,.Pessute_s:.fo SS_offits'-irizEx osure;Di f.4 Buildiri. , g;;Zone TYpe.`' Mean Roof ht; ft s 1'20 y 1.30 Basic,Wind'$ Deed' 140 150 4 60ri = m A 170 180r 190 200 20 26.0 30.5 35.4 40.6 46.2 52.2 58.5 65.2 72.2 25 27.0 31.6 36.7 42.1 47.9 54.1 60.6 67.6 74.9 30 27.9 32.8 38.0 43.6 49.6 56.0 62.8 70.0 77.5 Enclosed 4 40 29.4 34.5 40.0 45.9 52.2 58.9 66.1 73.6 81.6 50 30.6 35.9 41.6 47.8 54.3 61.3 68.8 76.6 84.9 60 31.5 37.0 42.9 49.3 56.1 63.3 70.9 79.0 87.6 Negative Loads) 5 20 32.1 37.7 43.7 50.1 57.0 64.4 72.2 80.4 89.1 25 33.3 39.1 45.3 52.0 59.2 66.8 74.9 83.4 92.4 30 34.5 40.4 46.9 53.8 61.3 69.2 77.5 86.4 95.7 40 36.2 42.5 49.3 56.6 64.4 72.7 81.5 1 90.9 100.7 50 37.7 44.3 51.4 58.9 67.1 75.7 84.9 94.6 104.8 60 38.9 45.7 53.0 60.8 69.2 78.1 87.6 97.6 108.1 Enclosed 4 20 16.7 19.5 22.7 26.0 29.6 33.4 37.5 41.7 1 46.3 25 17.3 20.3 23.5 27.0 30.7 34.7 38.9 43.3 48.0 30 17.9 21.0 24.3 27.9 31.8 35.9 40.2 44.8 49.7 40 18.8 22.1 25.6 29.4 33.4 37.8 42.3 47.2 52.2 50 19.6 23.0 26.7 30.6 34.8 39.3 44.1 49.1 54.4 60 20.2 23.7 27.5 31.6 35.9 40.5 45A 50.6 56.1 Positive loads) 5 20 16.7 19.5 22.7 26.0 29.6 33.4 37.5 41.7 46.3 25 17.3 20.3 23.5 27.0 30.7 34.7 38.9 43.3 48.0 30 17.9 21.0 24.3 27.9 31.8 35.9 40.2 44.8 49.7 40 18.8 22.1 25.6 29.4 33.4 37.8 42.3 47.2 52.2 50 19.6 23.0 26.7 30.6 34.8 39.3 44.1 1 49.1 54.4 60 20.2 23.7 27.5 31.6 35.9 40.5 45.4 1 50.6 56.1 ALC15001.3 FL12194-R6 Page 4 of 4 This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 318" F-Channel 3/8" J-Channel 3/4" —'1 1/8" HEM T I.-T 3/4" ISOMETRIC VIEW 3/8' PROFILE ISOMETRIC VIEW 3/E' PROW ALUMINUM COILS, INC Soffits AppL-ndix D ALC15001.3 FL12194-R6 Page 1 of 4 This evaluation report is provided for Slate of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Fascia CREEK TECHNICAL SERVICES, LLC 3/4" 7/81, r 1/8" HEM 6"FASCIA i" BLANK 1/4" ISOMETRIC VIEW ALUMINUM COILS, INC Soffits Apoendix D ALC15001.3 FL12194-R6 Page 2 of 4 This evaluation report is provided for Stale of Florida product approval under Rule.61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 16" 04 Soffit o2snr 0179M is" BLANK; 3, / 8 PROFILE 0 0 0 0 0 000 0000•o oaoo n 00000 oaoo• ALUMINUM COILS, INC Soffits App6ndix D ALC15001.3 FL12194-R6 Page 3 of 4 This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 12" T4 Soffit 3 1/0" 7/8" 3 1/6" 7/8" 3 1/8" 5/16" 1/2" 1/2" 1/2" 1/2" 1/2" 3/4" 1/8" 1/8" 3/8" oss-,yp o artvv 13.75" BLANK 3/8" PROFILE LITrRE/ n6dood 00 aaaao s oao aoaaa oaoo ALUMINUM COILS. INC Soffits Appendix D END OF REPORT ALC15001.3 FL12194-R6 Page 4 of 4 This evaluation report is provided for Stale of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which (his report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Florida Building Code Online Page 1 of 3 Profesfional r l r BCIS Home Log In User Registration Hot To".. Submit Surcharge I Scats B Facts { Publications FBC Staff BCIS Site Map' Links Search Or Product Approval 1' USER: Public User Product Approval Menu > Product or Appliwtlon Search > Application List > Application Detail FL FL7006-R10 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By J IKO Industries, Ltd 40 Hansen Road South Brampton, NON -US L6W 31-14 708)496-2800 Ext200 rmetzOO1@tampabay.rr.com Robert Metz rmetzOOI@tampabay.rr.com Bob Metz REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 727) 776-5261 rmetz001 @tampa bay. rr.com Don Shaw IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 717) 579-6706 don.shaw@iko.com Roofing Asphalt Shingles Certification Mark or Listing FM Approvals - CER Locke Bowden u Validation Checklist - Hardcopy Received Standard ASTM D3161 modified to 110 mph ASTM D3462 ASTM D7158 Class H ASTM E108 Year 2016 2010 2011 2011 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgse7mYBd2b3K... 2/6/2018 Florida Building Code Online Page 2 of 3 Product Approval Method Method 1 Option A Date Submitted 10/08/2017 Date Validated 10/30/2017 Date Pending FBC Approval Date Approved 11/01/2017 Summary of Products FL dt I Model, Number or Name Description 7006.1 Cambridge, Cambridge HD, Laminated architectural fiberglass asphalt shingle Biltmore and Biltmore HD manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.; Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL7006 RIO C CAC Letter - ASTM D3161 letter - (9-26- 2017) from FM.DdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL7006 RIO C CAC Letter - ASTM D3462 letter - (9-26- 2017).odfDesignPressure: N/A Other: FL7006 RIO C CAC Letter - ASTM E108 letter - (9-26- 2017).Ddf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 RIO 11 IKO-187-02-01 Letter - Installation Instructions for FBC FL7006.pdf Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.2 Hip and Ridge 12 Cap This is a 12" x 12" fiberglass asphalt shingle used to cover the hip and/or ridge of an asphalt shingle roof system manufactured at IKO's Kankakee, 1L, Toronto, Ont. and Brampton, Ontario plants. Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL7006 RIO C CAC ASTM D 3462 - ShinDle letter Approved for use outside HVHZ: Yes Impact Resistant: N/A Surveillance Audit Location - (6-28-2017).Ddf FL7006 RIO C CAC Letter - ASTM D3161 letter - (9-26- 2017) from FM.DdfDesignPressure: N/A Other: FL7006 RIO C CAC Letter - ASTM D3462 letter - (9-26- 2017). odf FL7006 RIO C CAC Letter - ASTM E108 letter - (9-26- 2017).Ddf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 RIO 11 Hip and Ridoe Cap Shinale Installation Instructions.Ddf FL7006 RIO 11 IKO-187-02-01 Letter - Installation Instructions for FBC FL7006.pdf Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.3 Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at Starter Strip the bottom of a roof system manufactured in Brampton and Hawkesbury, Ontario plants Limits of Use Certification Agency Certificate Approved foruse•in-HVHZ: Yes FL7006 RIO C CAC Letter - ASTM D3161 letter - (9-26- 2017) from FM.DdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL7006 R10 C CAC Letter - ASTM D3462 letter - (9-26- 2017).DdfDesignPressure: N/A Other: FL7006 RIO C CAC Letter - ASTM E108 letter - (9-26- 2017).odf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 RIO 11 IKO-187-02-01 Letter - Installation Instructions for FBC FL7006.odf FL7006 RIO 11 Roofing- Prod ucts-Leading-Edoe-Plus- Apol ication-EN(I ). odf Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: https://www. floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgse7mYBd2b3K... 2/6/2018 Florida Building Code Online Page 3 of 3 7006.4 Marathon Plus AR, Superglass Plus 3 tab fiberglass asphalt shingle manufactured at IKO's AR Brampton, Ontario, Hawkesbury Ont., Toronto, Ont.; Sylacauga, AL and Kanakakee, IL plants Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL7006 R10 C CAC Letter - ASTM D3161 letter - (9-26- Approved for use outside HVHZ: Yes 2017) from FM.odf Impact Resistant: N/A FL7006 R10 C CAC Letter - ASTM D3462 letter - (9.26- Design Pressure: N/A 2017).odf Other: FL7006 R10 C CAC Letter - ASTM E108 letter - (9-26- 2017).odf Quality Assurance Contract Expiration Date 12/20/2020 Installation Instructions FL7006 R10 II IKO-187-02-01 Letter - Installation instructions for FBC FL7006.odf Verified By: DuC T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: Back Next Contact us :: 2601 Blair Stone Road. Tallahassee FL 3230o Phone: SSO-487-1824 The State of Flonda is an WEED employer. f.+ovrroM 007• DIz Stet of Fonda. ;: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. if you do not want your a -mall address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. 1f you have any questions, please contact 850.487.2395. -Pursuant to Section 455.275(1), Flonda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The !mails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here . Product Approval Accepts: M ®®R704!n Cred-t Card Safe https://www. floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgse7mYBd2b3 K... 2/6/2018 CONSTRUCTION MATERIALS TECHNOLOGIES October 27, 2017 IKO Industries, Ltd 120 Hay Rd. Wilmington, DE 19809 Re: FBC FL7006 Sir(s), PRI Construction Materials Technologies has completed a technical review and attached sealed shingle instructions in compliance the 2017 Florida Building Code. This review was completed based on the receipt of following evidence from IKO Industries, Ltd: 1) IKO Shingle Application Instructions — 3-Tab Shingles EN-3Tab Appins_BAGXEFS-2012-11 reformatted 2013-02-rev07/13-Florida) 2) IKO Laminated Shingles Application Instructions EN-Laminated_Appins_8TTEFS-2012-04 reformatted 2013-02-rev07/13-Florida) 3) IKO Hip and Ridge 12 Application Instructions EN-HipandRidge12_3HRTri-2013-08_reformatted 2013-08) 4) IKO Leading Edge Plus Shingle Application Instructions EN-3LEP-Tri-2012-06_reformatted 2013-03) 5) ASTM D3161 Test Report (FM Approvals Project No. 3040947) The attached instructions should be used in conjunction with the published manufacturer's application instructions and applicable code. In the event the instructions conflict, these instructions shall govern. Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. Signed: ! C Signed: r Brad Grzybo ski Duc T./NJ u en Managing Dfrector Florida Re ere .Professional Engineer P.E. Number: 65034 Date: October 27, 2017 Date: October 27, 2017 Attachments: A) IKO Shingle Application Instructions - 3-Tab B) IKO Laminated Shingles Application Instructions C) IKO Hip and Ridge 12 Application Instructions D) IKO Leading Edge Plus Application Instructions IKO-187-02-01 PRI Cortctnxtion Materials Technologies, I.I.C. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621.5777 Fax: 813-621.5840 email. material9esbng@pricmtc0m WebSite: h1p://www.pdantcom IKO Installation Instructions for Asphalt Shingles Page 2 of 5 IKO Shingle Application Instructions — 3-Tab Shingles ASTM D3161, Class F — IKO Marathon 25 AR and CRC Superglass M25AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed 6-1/8" above the butt edge, approx. 1" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (600) or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8". STEEP SLOPES iLi STMP — 1 ::TSEAUNG C6-118- r' NAILS ! NAILS DO NOT NAIL INTO OR ABOVE THE SEALING STRIP PRI Construction Materials Technologies, U.C. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax. 813-621.5840 email: materialstesbng@prianLcom WetShe: http:/AwAv.pricmLcom IKO Installation Instructions for Asphalt Shingles Page 3 of 5 IKO Laminated Shingles Application Instructions ASTM D3161, Class F — Cambridge, Cambridge HD, and CRC Biltmore AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. 'For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed in the nail line 7-3/8' below the top edge, approx. 1" and 13" in from each end. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (600) or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8". 6 31 NAIL LINE NAILING - STEEP SLOPES APPLICATION Use six nails as shown. r [nz r] rj CEMENT PROPER APPLICATION REOUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OF THE SHINGLE PRI Conswdan Matenals Tednrologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-SM Fax: 81M21.5840 e-mail: matenalmesGng@0cmLoom WebSde: h1tpJlwww.pricmLcom IKO Installation Instructions for Asphalt Shingles Page 4 of 5 IKO Hip and Ridge 12 Application Instructions ASTM D3161, Class F — IKO Hip and Ridge 12) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTIO.N WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. Cut hip and ridge shingles into thirds, using.the perforation marks as a cutting guide. These shingles are designed for a 51/8" (130 mm) exposure. (For a neater appearance, the top of each side of each piece has been factory trimmed on a 1" (25 mm) taper (see drawing). Bend each piece over the hip or ridge, and nail 5 5/8" (143 mm) above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 1/8" (130 mm). Apply hip pieces starting at the lower end of the hip, working up toward the ridge. On hip roofs, apply ridge pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end opposite to the prevailing wind direction and continue to the other end. Note: To obtain a three-dimensional effect, (which is recommended, but not required), apply hip and ridge shingles double thickness by stacking 2 pieces on top of one another, the lower piece extending about 3/4" (19 mm) further than the top piece (see diagram). The final shingle should be set in cement, and the exposed nail heads of the final shingle should be covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for easier bending. NOTE: SHINGLES MUST BE APPLIED PROPERLY. THEY ARE DESIGNED FOR USE AS HIP AND RIDGE SHINGLES ONLY, AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS. REVIEW ALL APPLICABLE BUILDING CODES, MINIMUM PROPERTY STANDARDS, AND REQUIREMENTS PRIOR TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. C5 ten) TAPER CO PW ConeUuctron Materials Technologies, L.I.C. 6412 Badger Drive Tampa, FL 33610 Tel- 813.621.5777 Fax: 813-621.5840 e-mail: materialsiesung@pripnLcom WetiSite: http./Avww.pritmLtom IKO Installation Instructions for Asphalt Shingles Page 5 of 5 IKO Leading Edge Plus Application Instructions ASTM D3161, Class F — IKO Leading Edge Plus) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. 1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required. 2. Each 39 3/8" x 131/4" (1000 mm x 336 mm) IKO Leading Edge Plus strip is perforated lengthwise for separation into two (2) shingles. Take one IKO Leading Edge Plus strip and fold flat at perforation to separate. 3. Take one of the separated shingles 39 3/8" x 6 5/8" (1000 mm x 168 mm) and remove approximately 20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up, with the factory installed sealant adjacent to the eaves. The shingle should overhang the rake edge and eaves by a nominal 114" (6 mm) minimum. Fasten the shingle to the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge and 1" (25 mm) in from each end. 4. Take the leftover 20" (500 mm) piece shingle. Rotate the piece and align it vertically up the rake edge with the factory installed sealant adjacent to the outer edge of the roof. The shingle should overhang the rake edge by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with fasteners located 3" to 4" (75 mm to 100 mm) from the rake edge and 1" (25 mm) in from each end. 5. Repeat Steps 3 — 4 for the right lower corner of the roof deck. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" (9 mm) diameter heads, long enough to penetrate through plywood or 3/4" (20 mm) into boards. Use 4 nails per shingle placed 3" to 4" (75 mm to 100 mm) from the eave edge and approximately 1" and 13" (25 mm and 330 mm) in from each end. 6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck. Install the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingles to the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge, 4 nails per shingle. 7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first -course field shingles and help keep them from lifting in high winds. PFJ ConswelJon Materials Teduwlogies, I.I.C. 6412 Badger Dnve Tampa, FL 33610 Tel. 813-621.5M Fax, 813.621.5840 e-mail: materials1esbn9@pri0mLo0m WebSite, htlpJMrww.pricmLwm Florida Building Code Online Page 1 of 2 man00 + o SCIS Mont Lop In I User RtpiStration Hot Topics Subrrut Surcharge Stats & Facts { Publications FBC Stall E SCIS Site Map Unks Search be%r a Product Appro val USER: Public User e=' Product Auproval Menu > Product or Aoohcatlon Search > Application List > Application Detail FL # FL15216-113 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method L. InterWrap, Inc. 32923 Mission Way Mission, NON -US 00000 551) 574-2939 mtupas@interwrap.com Eduardo Lozano elozano@interwrap.com Eduardo Lozano 32923 Mission Way Mission, NON -US 00000 778) 945-2891 elozano@interwrap.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 09/30/2019 Validated By John W. Knezevich, PE G Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL15216 R3 COI 2017 01 COI Nieminen.Ddf Standard ASTM D1970 (tear) ASTM D226 (physicals) Year 2015 2009 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param= A,GEVXQwtDgv3yVVKJZI Q... 2/6/2018 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL it IModel, Number or Name Description 15216.1 RhinoRoof Underlayments Synthetic roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL15216 R3 II 2017 10 FINAL ER INTERWRAP RHINOROOF FL35216- R3.DdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Robert Nfeminen PE-59166 Design Pressure. N/A Created by Independent Third Party: Yes Other: See ER Section 5 for Limits of Use. Evaluation Reports FLIS216 R3 AE 2017 10 FINAL ER INTERWRAP RHINOROOF FL15216- R3. Ddf Created by Independent Third Party: Yes Fade Next Contact to :: 2601 Blair Stone Road. Tallahassee Fl. 32399 Phone: OSO-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007,2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the Office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The !mails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine it you are a ficensee under Chapter 455, F.S., please Click here . Product Approval Accepts: MERE Crud-d Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZI Q... 2/6/2018 QOTRINITYIERD EVALUATION REPORT Interwrap, Inc. 32923 Mission Way Mission, BC V2V-6E4 Canada 551)574-2939 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorizotion #9503 353 CHRISTIAN STREET, UNIT #113 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 140510.02.12-113 FL35216-R3 Date of Issuance:02/17/2012 Revision 3:10/20/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6"' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: RhinoRoof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, C.E. on 10/10/2037. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. l TRINITY I ERD ROOFING COMPONENT EVALUATION: 1.. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: RhinoRoof Underlayments, as produced by Interwrap, Inc., has demonstrated compliance with the following sections of the 6'h Edition (2017) Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS. Section Properties Standard Year 1507.1.1, T1507.1.1 Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1.1 Tear Strength ASTM D1970 2015 3. REFERENCES: - iaiitf Examination Reference Date ITS (TST1509) Physical Properties 100539395COQ-006 10/27/2011 ITS (TST1509) Physical Properties 100539395COQ-002 10/27/2011 ITS (TST1509) Physical Properties 100539395COQ-006 03/14/2014 PRI (TST5878) ASTM D1970; Tear strength OCF-330-02-02 10/03/2017 ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 4. PRODUCT DESCRIPTION: 4.1 RhinoRoof U20 is a multilayered polymer woven coated synthetic roof underlayment available in 42-inch wide rolls, and can be produced in various other sizes; meets FBC 1507.1.1 (Exception). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. . 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 RhinoRoof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: 5.6 Exposure Limitations: RhinoRoof U20 shall not be left exposed for longer than 30-days after installation. Exterior Research and Design, U.C. Evaluation Report 140510.02.12-113 Certificote Of Authorizotion #9503 6:" EDITION (2017) FBC NON-HVHZ EVALUATION F1.15216-113 RhinoRoof Underlayments Revision 3:10/10/2017 Page 2 of 3 VTRINITYIERD 6. INSTALLATION: 6.1 RhinoRoof Underlayments shall be installed in accordance with Interwrap, Inc. published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet - width for double -layer applications. 6.3.1 Fasteners: For exposure < 24 hours, corrosion resistant fasteners may be 1-inch roofing nails with a 3/8-inch diameter head, or those noted in 6.4.2. The use of staples is prohibited. For exposure > 24 hours up to maximum 30 days, corrosion resistant fasteners shall be minimum 1-inch diameter plastic or metal cap nails or FBC HVHZ nails.& 1-5/8" diameter tin caps (with the rough edge facing up). The use of staples is prohibited. 6.3.2 Single Laver: Roof Slope > 4:12: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. Refer to Interwrap, Inc. recommendations for alternate lap configurations and/or the use of sealant under certain conditions. For exposure < 24 hours, use of every -other fastening location printed on the surface is acceptable. For exposure > 24 hours up to maximum 30-days, use of every fastening location printed on the surface is required. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens on the same day. Battens shall not be positioned over cap nails. If this occurs, remove the cap nail and patch the hole in accordance with Interwrap published instructions. 6.4.3 Double Laver: 2:12 < Roof Slope < 4:12: End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum half -sheet -width plus 1-inch. Double layer application; begin by fastening a half -width plus 1-inch starter strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.5, but maintaining minimum half -width plus 1-inch side (horizontal) laps, resulting in a double -layer application. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Qingdao, China 9. QUALITY ASSURANCE ENTITY: Intertek Testing Services NA Inc. — QUA1673; (608) 836-4400 END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 140510.02.12-R3 Certificate ojAuthorizotion #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL15216-113 RhinoRoof Underlayments Revision 3:10/10/2017 Page 3 of 3 Rhin®foof ® U20 Synthetic Roofing Underlayment RhinoRoof' U20 Installation Instructions RhinoRoof' U20 is an air, water and vapor barrier and therefore must be installed above a properly ventilated space(s). Follow ALL building codes applicable to your geographical region and structure type as it is considered a vapor barrier. DECK PREP: Protrusions from the deck area must be removed and decks shall have no voids, damaged or unsupported areas. Deck surface should be free of debris, dry and moisture free. USE: RhinoRoof' U20 must be covered by primary roofing within 60 days of application. U20 is designed for use under; asphalt or synthetic shingles, metal in residential applications, and cedar shakes that have been primed. APPLICATION: For slopes from 4:12 and higher RhinoRoof' U20 is to be laid out horizontally (parallel) to the eave with the printed side up. Horizontal laps should be 4" and Vertical laps should be 6°and anchored approximately 1 " in from the edge. For low slope applications it is recommended to overlap 505/o plus 1 ", for complete definition of low slope and guidelines consult authorities having jurisdiction. U20 product is not recommended for slopes less than 2:12. The use of roofing hammer, pneumatic air or gas driven fastener tools is acceptable. The use of straight edge cutting knives is recommended. FASTENERS: For same day coverage with primary roofing RhinoRoof' U20 can be anchored with corrosive resistant 3/8" head x 1" leg roofing nails (ring shank preferred, smooth leg acceptable). The use of every other anchoring location printed on the product is also acceptable. If U20 will be left exposed for up to 60 days the product must be anchored with 1" plastic or metal cap smooth or ring shank roofing nails and anchored in all locations printed on the facer. DO NOT USE STAPLES: the use of staples to penetrate RhinoRoof' U20 will void warranty. ANCHORING: All anchoring nails must be flush, 90 degrees to the roof deck, and tight with the underlayment surface and the structural roof deck. Where seams and joints require sealant or adhesive use a low solvent plastic roofing cement meeting ASTM D-4586 Type 1, or Federal Spec SS-153 Type 1 such as Karnak, Henry, DAP, MB, Geocel or equivalent. Acceptable alternatives are butyl rubber, urethane, and EDPM based caulk or tape sealant. EXTENDED EXPOSURE: If RhinoRoof' U20 product will be exposed longer than 24 hours and up to 60 days then product must be attached to the structural roof deck using a minimum 1 " diameter plastic or metal cap roofing nails (ring shank preferred but smooth leg acceptable). Miami Dade approved tin tags/metal caps are also acceptable, and it is recommended for best performance to use with the rough edge facing up. For extended exposure it is always recommended to anchor on every printed position on the facer. RhinoRoof' U20 is not designed for indefinite outdoor exposure. For extended exposure conditions where driving rain or strong winds are expected it is recommended to take additional precautions such as doubling the lap widths. Alternately or in addition to a compatible sealant could be used between the laps or a peel and stick tape could be applied to the overlaps. CAUTION - READ GOOD SAFETY PRACTICES BELOW Good safety practices should be followed on steep slope roofs, such as use of tie -offs, toe boards, ladders and/or safety ropes and personal body harnesses. Follow OSHA guidelines. Slip resistance may vary with surface conditions from debris that accumulates, weather, footwear and roof pitch. Failure to use proper safety gear can result in serious injury. Depending on roof pitch and surface conditions, blocking may be retluired to support materials on the roof and is good safety practice. Remember to seal the nail holes after removing blocking. InterWrap® Roofing Products Division Charleston, SC • Vancouver, BC • Mission, BC • Montreal, QC Web: www.InterWrap.com/roofing 1 E-mail: info@interwrap.com M Toll Free: 888 713 7663 1 Tel: 778 945 2888 Florida Building Code Online Page 1 of 2 SCIS Home I LW In I User Repistrabon i Hot Topics I Submit Surcharge I Stats B Facts { Publications I FBC Stall SCIS Site Map I Links I Search Florida re Product Approval ag IUSER. Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL16994-RS Application Type Revision Code Version 2017 Application Status Approved Comments Archived D Product Manufacturer Southeastern Metals Mfg. Co. Address/Phone/Email 11801 Industry Drive Jacksonville, FL 32218 904) 696-4682 jhkelsey@semetals.com Authorized Signature Jeremy Kelsey jhkelsey@semetals.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a .Florida Registered Architect or a Licensed Florida Professional Engineer Q Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/20/2020 Validated By Locke Bowden Validation Checklist - Hardcopy Received Certificate of Independence FL16994 RS COI SEM14001.5a 2017 FBC Eval Report Off-Ridoe Vent final.odF Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1503.5 1709.2 Product Approval Method Method 2 Option B https://www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgvBwYu9TrZN... 2/6/2018 Florida Building Code Online Page 2 of 2 Date Submitted 09/26/2017 Date Validated 10/10/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL a Model, Number or Name Description 16994.1 Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-18 FI 16994 R5 II SEM14001.5a 2017 FBC Eval Report Off - Ridae Vent final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FI 16994 R5 AE SEM14001.5a 2017 FBC Eval Report Off- Rldae Vent final.pdf Created by Independent Third Party: Yes 16994.2 Tile Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with clay or concrete tile Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-9 Other: See Evaluation Report for limits of use. Installation Instructions FL16994 R5 II SEM14001.5b 2017 FBC Eval Report Tile Roof Vent final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports Fi 16994 RS AE SEM14001.5b 2017 FBC Eval Report Tile Roof Vent final. Ddf Created by Independent Third Party: Yes Back Next Contact 11s :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: SS0-487.1824 The State of Florida is an AA/EEO employer, Copyright 2007.2013 State of Flonda.:: Privacy Statement :: ACCessibillty Statement :' Refund Statement Under Florida law, email addresses are public records If you do not want your e•mall address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which an be made available to the public. To determine If you are a licensee under Chapter 455, F.S., Please dlCk here'. ' Product Approval Accepts: w = ICJ E-79- M Crecr-it Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvBwYu9TrZN... 2/6/2018 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 336470 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6'" EDITION (2017) Manufacturer: Southeastern Metals Manufacturing Co., Inc. (SEMCO) Issued October 10, 2017 11801 Industry Drive Jacksonville, FL 32218 800) 874-0335 hftp://www.semetals.com Manufacturing Plant: Jacksonville, FL Quality Assurance: UL LLC (QUA1743) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1503.5, 1709.2 Properties: Roof Ventilation REFERENCES Enti PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) Zachary R. Priest, P.E. (CREEK Technical Services) PRODUCT DESCRIPTION Report No. Standard Year SEM-029-02-01 ASTM E 330 2014 SEM-031-02-01 ASTM E 330 2014 SEM14003 Calculations 2014 Off Ridge Vent: Minimum 26 ga. ASTM A792 or ASTM A653 CS Type B steel; Shall conform with FBC Section 1503.2 Maximum dimensions of the vent are 24-inch wide x 102-inch long x 4.25-inch high. Vent is available in nominal 4-ft, 6-ft and 8-ft sizes. SEM14001.5a FL16994-R5 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Southeastern Metals Manufacturing Co., Inc. CREEK Off Ridge Vent TECHNICAL SERVICES, LLC PRODUCT APPLICATION Deck Type: Minimum 7/16-inch APA span rated OSB sheathing or 15/32-inch APA span rated plywood sheathing for new and existing roof deck (Deck shall be designed by others in accordance with FBC requirements). Roof slope: Minimum 2:12 Installation Height: Maximum 33-ft Roof Cut -Out 2.5-inch wide x 42-inch opening for the nominal 4-ft vent 2.5-inch wide x 66-inch opening for the nominal 6-ft vent 2.5-inch wide x 90-inch opening for the nominal 8-ft vent Attachment Method: Cut-out opening as prescribed above into the sheathing located a minimum 6-inch off the ridge. For a single vent, install the vent as close to the center of the roof length as possible. Multiple vents should be evenly spaced along the roof length. Remove interfering shingle nails around the perimeter of the opening and any debris prior to placing vent. Apply ASTM D 4586 or ASTM D 3409, Type I roofing cement/mastic to the underside of the perimeter flange to continuously surround and seal the flange. Position the vent over the opening in the roof sheathing. Slide the top and side flanges of the vent underneath the shingles and allow the bottom flange to lie on top of the shingles. Attach the vent with #9 x min. 1.5-inch HWH screws with 0.5- inch sealing washers or min. 12 ga. x 1-1/4-inch ring shank nails with min. 3/8-inch diameter heads having sufficient length to penetrate through the sheathing a minimum of 3/8-inch. The fasteners shall be located 1-inch from the edge of the flange and 5.5- inches o.c. along all four sides of the vent. All loosened shingles shall be adhered down with roof cement/mastic. When nails are used to attach the vent, all penetrations through the vent flange shall be sealed using ASTM D 4586 or ASTM D 3409, Type I roofing cement/mastic. Allowable Roof Coverings: Asphalt shingles Maximum Design -13.5 psf for 4-ft and 6-ft vents Pressure -18 psf for 8-ft vent Pressures calculated using 2.1 margin of safety per 1504.9 SEM14001.5a FL16994-R5 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Southeastern Metals Manufacturing Co., Inc. CREEK OH Ridge Vent TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is outside the scope of this evaluation. 2) This report is not for use in the HVHZ. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) SEMCO vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 6) Installation of the roof assembly is outside the scope of this evaluation. 7) SEMCO vents are intended to provide passive ventilation for an enclosed attic in residential construction applications 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPUANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have' demonstrated compliance with the Florida Budding Code, 6v' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. R. • P, 9lo No 74021 STATE OF i4U / F'•. C 0 R sS/0 N AL ,.` CERTIFICATION OF INDEPENDENCE 2017.10.10 10:29:43 Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will -acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT SEM14001.5a FL16994-R5 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MIAMI-D.ADE COUNTY MIAMI-DARE PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD N'D CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) w.vw.miamidade.eov/economv Southeastern Metals Manufacturing Company, Inc. 11801 Industry Drive Jacksonville, FL 32218 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Weather Vent LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 08-0423.01 consists of pages 1 through 3. The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 13-0814.08 Expiration Date: 04/15/19 Approval Date: 01/23/14 Page 1 of 3 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Ventilation Material: Steel Minimum Slope: 2:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Manufactured by Applicant Weather Vent Dimensions Vent: 4-%"x19"x46" Deck Flange: 24" x 52" Thickness: 0.0217 inch. MANUFACTURING LOCATION 1. Jacksonville, FL EVIDENCE SUBMITTED Test Agency PRI Asphalt Technologies, Inc. APPROVED APPLICATIONS: Deck Type: Wood Test Identifier TAS 100 ICC-ES AC 132 Test Product Specifications Description TAS 100 Galvanized metal roof vent Deck Description: 15/ 32" or greater plywood or wood plank System Type A: Mechanical attachment of vent for shingle roofs Test Name/Revort SEM-002-02-01 SEM-027-02-01 Date 08/14/03 01/07/14 Cutout: Mark a 3'/z" x 46" opening centered between layout lines and aligned minimum 6 inches from the ridge. Set blade to thickness of sheathing and cut opening. Brush away sawdust and debris. Installation: Vents should be evenly spaced on the rear slope of the roof. Center vent in opening and set it in a 1 /8" thick of an approved ASTM D 4586 asphalt roofing cement. Secure vent -to the roof deck with 1-'/4" galvanized ring shank roofing nails spaced approx. 8" o.c. and 1" from the outside edge of the flange. Use a minimum of 18 nails per vent. Seal all nails and vent flange with an approved ASTM D 4586 roofing cement. (See drawings herein). Net Free Area: 99 square inches. NOA No.: 13-0814.08 Expiration Date: 04/15/19 Approval Date: 01/23/14 Page 2 of 3 LIMITATIONS: 1. Refer to applicable building code for required ventilation. 2. Weather Vent shall comply with the manufacturer's current published application instructions and the requirements set forth in the applicable building code. 3. This acceptance is for installations over asphaltic shingle roofs only. 4. Weather Vent shall not be installed on roof mean heights greater than 33 feet. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 6. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below: MIAMI-DADE COUNTY M DRAWINGS ROOF FLANGE NAIL PLACEMENT END OF THIS ACCEPTANCE NOA No.: 13-0814.08 CMLADADE COUNTY Expiration Date: 04/15/19 Approval Date: 01/23/14 Page 3 of 3 CITY OF SANFORD BUILDING & FIRE PREVENTION z PERMIT APPLICATION rw + siren -try nj Application No: Documented Construction Value: S Job Address:.3 9 (v<!a 5C,LI -} rn %5 h Lu4 Historic District: Yes No Parcel ID: Residenti40--Commercial Type of Work: NevvQ"`Addition Alteration Repair Demo Change of Use ove Description of Work: Plan Review Contact Person: Title: Phone: Fax: Email: Property Owner Information Name Phone- Street: Resident of property? City, State Zip: Contractor Information Name S Phone: 8/3 -9io 3 4v3 CA4 23 -Q- Street: DDP1 a Fax: City, State Zip-IA_f_ F 55 L/3 State License No.: CC 1.3 005 NCU,' Name: Street: City, St, Zip: Bonding Company: Address: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application U NOTICE: In addition to the requirements of this'permit, there may be additional restrictions applicable to this property that may befoundinthepublicrecordsofthiscounty, and there may be additional -permits sequired from other governmental entities such as water _ management districts, state agencies, or federal agencies. - at i will notify the owner of the property of the requirements of Florida Lien Law, FS 713. Acceptance of permit is verification th The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is requiredinordertocalculateaplarireviewchargeandwillbeconsideredtheestimatedconstructionvalueofthejobatthetimeofsubmittal. The actual construction value will be figured based on the current ICC' Valuation.Table in effect at the time the permit is issued, inaccordancewithlocalordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit'is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction an ping./ signature ofOwndr/Agent - Date ' Print Owner/Agent's Name Signature of Notary -State of Florida Date , Owner/Agent is PersonallyrKnowrito Me or - Produced ID . Type of ID Print Contractor/Agent's Name LL sipature011, tery-state ifF! d; O'Clalr Date jl 4p CoJmm alSshto t` f GGi 51701 Expires: paober 15, 2021 bsonuau tllttr;wljrr, IY wf _ •• Contractor/ Agent is Pe sonally Known to-W Produced ID Type - BELOW IS FOR OFFICE USE ONLY Permits Required: Building El trical Mechanical Plumbing[] Construction Type: Occupancy Use: S Ft f Bld Min. Occupancy Load: Gas[] Roof Flood Zo#e: of Stories: Dtal g o g. New Construction: Electric - # of Amps - Plumbiiig= # of Fixtures Fire Sprinkler Permit: Yes No # of He . Fire Alarm Permit:* Yes No APP110VALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: WASTEWATER: FIRE: BUILDING: Permit Application Revised: June 30, 2015 CONTRACT AGREEMENT I PAOE 1-4-7 OF 1 4 JOB NAME: DATE: 6/21/2017 MIFEWTYR OR WS AGENT: =QwENT: ELECTRICAL CONTRACT REVISED .. PARK SQUARE HOMES m: LEVEL I - WITH CFL BULB5 jUu: GAS/ELECTRIC ADDRH33: 5200 VINELAND RD m&ww: ORLANDO C" 1TY: ORLANDO Alm: FL M: SANFORD mn: FL WYNDHAM PRESERVE PLAN SERVICE SIZE SQ FT A/C SYSTEM PRICE SEBRING 200A 2410 30-kW HEAT 240V, 60A 6,758.00 5-TON AC 240V, 50A SORRENTO 200A 2078 8-kW HEAT 240V, 50A 5,465.00 4 TON AC 240V, 40A SPRUCE 200A 2774 8-kW HEAT 240V, 50A 7,264.00 4-TON AC 240V, 40A SUNDANCE 200A 1730 5-kW HEAT 240V, 35A 5,082.00 3-TON AC 240V, 30A TELLURIDE 200A 2637 10-kW HEAT 240V, 60A 6,601,00 5-TON AC 240V, 50A TRIBECA 200A 1986 8-kW HEAT 240V, 50A 5,608.00 4-TON AC 240V, 40A TUSCANY 200A 2718 10-kW HEAT 24OV, 60A 6,818.00 5-TON AC 240V, 50A WALTON I) 200A 1811 8-kW HEAT 240V, 50A 5,110.00 4-TON AC 240V, 40A WELLINGTON 200A 3075 4N 2) SAW HEAT 240V, 35A 7,587.00 QTY 2) 3-TON AC 240V, 30A CONTRACTOR/OWNER: _ EDMONSON ELECTRIC: _ 1034 Skipper Road • Tampa, Phone:(813)910-3403 • Fax:(813)91 PLORIDA Mrs"SB / L=C17005408 DATE: DATE: 46 . www.EdmonsoriElectric.com f. CITY OF SANFORD BUILDING & FIRE PREVENTION D PERMIT APPLICATION Application No: Documented Construction Value: S Job Address: 3 `q Q fql mdvjh C.v Historic District: Yes No Parcel ID: Residential Rj-' Commercial rVITypeofWork: New `/y Addition Alteration Repair Demo Change of Use ve Description of Work: ()VyltiVL 0 %f t, ;j S C 1j n Plan Review Contact Person: Title: Phone: Fax: Email: Property Owner Information Name Phone: Street: Resident of property?: City, State Zip: Contractor Information Name UY co-ft Lot6 C tree y Phone: -- g(j i - q/' 0 Street: ' 40 S t r. Fax: `i 07 - 9 7l - V 3-G ( City, State Zip: C {- Ucyd- 1 rt 3H 711 State License No.: Cpcl d a'-*0 Arch itect/EngIneer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. F RC105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51" Edition (2014) Florida Building Code Revised: June 30, 20)5 Permit Application f NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ]CC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Sigr lature o on for/Agent ' L ate IV t L L t i1 j CG'Lf Print Contractor/Agent's Name Contractor/Agent is Personally Produced ID Type of ID _ BELOW IS FOR OFFICE USE ONLY FERIV,! 7. 2p ip TIFF 120855 -7 Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Flood Zone: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps, Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: COMMENTS: ENGINEERING: Plumbing - # of Fixtures Fire Alarm Permit: Yes No UTILITIES: WASTE WATER: FIRE: BUILDING: Revised: June 30, 2015 Permit Application CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: ( L,s Documented Construction Value: S 1,0200 CC) Job Address: Historic District: Yes El .No i" Parcel ID: Residential Commercial T pe of Work: NeN% 0 addition alteration CRepah D Demo ll Change oof,Use_mo e Description of \ or I:: I L Q I I j4<< r _=i1 I i'F Tel^ 1(> Plan Review Contact Person: J Title: Phone: Fax: Email: Property Owner Information Name . L iQl Phone: Street: Resident of property? : City. State Zip: Contractor Information Name i%, ` %DTI "'(1 ,1 I l'!! Phone: G / ( 1 Street: ' r 11 1 l Fax: C,i_'' F ( Q0; Cih•. State Zip: - `dal 1C'r r1 i ' I State LicenseNo.: Name: Street: City. St. Zip: Bonding Company: Address: Architect/ Engineer Information Phone: Fax: E- mail: Mortgage Lender: Address: W' AI`\ ING TO OW DER: YOUR FAILURE TO RECORD A NOTICE_ OF COMMENCEMENT IIA1' RESULT IN YOUR PALING TWICL FOR IMPROVEMENTS 1.0 YOUR PROPER'rl'. A NOTICE OF COMMENCEMENT \JUST RE RECORDED AND POSTED ON THE .JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND 1.0 OUTMN FINANCING. CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. 1. : , 1., i- :1.+ :1.. r ' ' .1. :i': t > \\. .. J ...,II-.• .. j\ t'i' 7113. connin.". :ed. Prior !o the liitnnice Cf F! permii .^.Eli i!1'_'i all work 1v ill b: per iori:l-v io nl ,c, siand3rds of all 13-xs r i'ti!»ili?S' lC r,j;rtl ii.n his urisdiciion. I understand that a separate permit must be secured for electrical Mork. plumbing. signs. wells. Paul>, furnaces. t> uilers; heatrr>. tanks. and air conditioners. etc. FCC 1114. 3 Shall he inscribed with th date of applicat4m and the code in eff:•ci c of that date: 4`' Cditinn (2014) Ilorida Huildia_ Code Jun: ,(: 261; 1 ICL: In addition to the requirements of this permit, there maN be additional restrictions applicable to this propem that maybe found in the public records of this counry. and there may be additional pernuts required from other governmenia! entities such as wat:r management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notif`• the owner of the properly of the requirements of Florida Lien La%v. FS i 1-. The City of Sanford requires payment of a plan r,-view fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction vnitte of the job at the time of submittal. The actual construction value .•ill be fieurcd bated on the current iCC Valuation Table in effect at the time the per•rnit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value. credit will be applied to your permit fees when the permit is issued. ONVNER'S AFFIDAVIT: l certifv that all of the foregoing information is accurate and that all work Nvill be done in compliance -with all applicable laws regulating construction L o=!ng. rn: Ox%mr.-A¢:n:'s Xane ia::nur_ of N'ot3re•5r_t: of Fio-ida Date Owner/.gent is Personally Known to Nle or Produced ID Type of ID Contractor'.-ksent is ' Personally V--io\rn to Me or Produced iD Type of iD BELOW IS FOR OFFICE USE ONLY Perniirs Required: Building El;ctrical N-I.chaalcal Plumbing[] Consttuction'I'N•pe: Occupancy Use: Gas[] Roof Flood Zone: Total Sq Ft of Bldg: Mn. Occupancy load: = of Stories: New Construction: Electric - = of Amps Plumbing - r of Fixtures Fire Sprinkler l'uniii: Yes No ' of Heads Fire .alarm Permit: ties \o APPROVALS: ZONI_NG: UTiLITiES: WASTE WATER: E\GI\EERNG: FIRE: BUILDFNG: CO>1.\11: NTS: re A DIVISION Of PARK SQUARE ENTERPRISES LLC ford Fire Prevention Division k Ave 32771 It May Concern: dvised that Edmonson Electric has been released from the following permits: 3962 Saltmarsh Loop 3860 Saltmarsh Loop 2631 Flycatcher Way 3830 Loon Lane 2614 Green Swallow 3767 Saltmarsh Loop Dntractor is Strada Electric. Please let me know if you need anything else to rE an be reached at 407-529-3163 or tpickeringC&Darksquarehomes.com . for assistance with this matter. ring Coordinator, Park Square Homes 15 lightyears, Inc 15 776 Bennett Drive Longwood, Florida 32750 June 1, 2018 To: Local Building Department RE: Blower Door Test & Duct Leakage Test Reports To whom it may concern, lightyears This letter is to request that the attached forms be accepted for compliance of the 2017 Florida Building Code statute R402.4.1.2 Envelope leakage testing (Blower Door Testing) and R403.3.3 Duct testing. The attached forms were provided by the Florida Building Commission as the accepted forms to be submitted. These forms are listed on the 2017 Florida Building Code, Energy Conservation Technical Assistance Manual, Document Number: TAM-2017-1.0, released February 02, 2018, pages R-78 through R-80 (page numbers 159-161). Web link provided for quick access to the TAM document https://tinyuri.com/2017FBC-TAM These forms meet all three required Residential Energy Efficiency Compliance Paths listed under R401.2, Prescriptive, Performance, and Energy Rating Index (ERI) paths. We are working with building departments across Florida to standardized the form submittal process and would like your department to allow these forms to meet compliance. If there are any issues with accepting these forms, please reach out to me directly and I will ensure that we submit any specific form that you will require. Tim Smith (407)-951-3236 tsmith@151ightyears.com Respectfully, 2 Timothy-Sfiiith 15 Lightyears, Chief Operations Officer Energy Technical Advisor RESNET Quality Assurance Designee IECC Residential Energy Inspector/ Plans Examiner Member, Building Officials Association of Florida Member and Code Development Committee participating member. Also, representative to the Florida Building Commissions, Energy Technical Advisory Committee for the BOAF- CDC Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Fjurisdiction: Permit #: Job Information Builder: t i+rK S it Community: 0 nd.jrj Lot: y.3 Address: ,3gG Z C,+ Unit: City: V'1074'c/ State: F/. Zip: XZ-i3 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method OPRESCRIPTIVE METHOD- The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2. KERFORMANCE or ERI METHOD- The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or R406-2017 (ERI), section labeled as Infiltration, sub -section ACH50. ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): I4 0 2 X 60 _ tC?0 0101 5.03 Method for calculating uilding volume: CFM(50) Building olume ACH(50) O Retrieved from architectural plans 000PASS (Mechanical Ventilation is not required) Code software calculated PASS (with Mechanical Ventilation) O Field measured and calculated FAIL R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as set forth in Section 489.105(3)(0, (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code ofcial. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3.lnterior doors, if installed at the time of the test, shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems, if installed at the time of the test, shall be turned off. 6.Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: 15 Lightyears, Inc Phone: (855)438-1515 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: Aaron Overholt License/Certification #: 2DNAB7 Issuing Authority: RESNET Copy of License / Certificate of the tester must be attached) Duct Leakage Test Report 1. 1- • - 1 . Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit #: Job Information Builder:isc,-4r,-c Community: d..,Lot: y/,3 Address: 39GZ SA-c.4 a- P Unit: City: State: Zip: 92773 Duct Leakage Test Results System 1 37 cfm25 System 2 cfm25 System 3 cfm25 Sum of any additional systems cfm25 Total of all systems cfm25 OPrescriptive Method cfm25 (Total) To qualify as "substantially leak free" Qn Total must be less than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.3.3. Is the air handler unit installed during testing? YES (a;) E—]NO (',,'3) performance / ERI Method cfm25 (out or Total) To qualify using this method, Qn must not be greater than the 37 + 2078' = -0t"1 Qn proposed duct leakage Qn specified on Form R405-2017 or R406-2017. Total of all Total Conditioned systems Square Footage leakage Type selected on Form Qn specified on Form R405-2017 R405-2017 (Energy Calc) or R406-2017 (Energy Calc) or R406-2017 tPASS PrD . Leo e F-r6G 67) o 3 Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes. Testing Company Company Name: 15 Lightyears, Inc Phone: (855) 438-1515 1 hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: Aaron Overholt License/Certification #: 2DNA137 Issuing Authority: RFRNFT Copv of License / Certificate of the tester must be attached) LL L W z N W Cd Certificate of Achievement THIS ACKNOWLEDGES THAT Aaron Overholt HAS MET THE STANDARD REQUIRED BY RESNET, AS A CERTIFIED RATING FIELD INSPECTOR Certification Date: 08/07/2018 Certification Expires: 08/07/2021 RFI # 2GNAB7 7,1Z Tim Smith, RESNET Quality Assurance Designee 15 14ightyears RESNET QA Provider # (1998-199) CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: $ 6298.00 Job Address: 3962 Saltmarsh Loop Historic District: Yes No Parcel ID: 17-20-31-502-0000-0430 Lot 43 Residential ® Commercial Type of Work: New ® Addition Alteration Repair Demo Change of Use Move Description of Work: Install new 3-ton HVAC system with duct work Plan Review Contact Person: Paula Bagley Title: Permit Clerk Phone: 407-975-2762 Fax: 407-629-9307 Email: permitting@onestopcooling.com Property Owner Information Name Park Square Homes Phone: 407-529-3000 Street: 5200 Vineland Rd #200 Resident of property? : City, State Zip: Orlando, FL 32811 Contractor Information Name One Stop Cooling & Heating, LLC Phone: 407-975-2762 Street: 7225 Sandscove Court Fax: 407-629-9307 City, State Zip: Winter Park. FL 32792 State License No.: CAC 032444 Arch itectlEngineer Information Name: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be perfonned to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit trust be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be Inscribed with the date of application and the code In effect as of that date: 51° Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application t NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued., OWNER'S AFFIDAVIT: I certify that all of the fore$Oing information is accurate and that all work will be done in compliance with all applicable laws regulati g 96nstructipn and zoning. Signature of Owner/Agem Print O%vner/Agent's Name Date Signature of Notary -State of Florida Date r' Kevin Stine Print Contractor/Agent's Name Signature Date KELLY WEBSTER Notary Public - State of Florida Commission # FF 978034 My Comm. Expires Apr 4, 2020 Owner/Agent is Personally Known to Me or Contractor/A ei t Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[-] Roof Construction Type: Occupancy Use: Flood Zone: _ Total Sq Ft of Bldg: Min. Occupancy Load: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures. Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: June 30, 2015 Pennit Application