Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1810 Rinehart Rd; 18-1702; INTERIOR REMODEL
CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: _ - 0`2 Documented Construction Value: $ $50 , 3.00 0 Afq Job Address: 1810 Rinehart Rd., Sanford, FL 32771 Historic District: Yes No X Parcel ID: _ 29-19-30-512-0000-0010 Residential Commercial Type of Work: New Addition Alteration E Repair Demo Change of Use Move U Description of Work: Interior alterations for fit out of an indoor trampoline park. Scope of work includes new restrooms/plumbing fixtures, interior walls and doors, electrical, mechanical, and structural which includes a raised matni shidqnd plywnnrl platform Plan Review Contact Person: Robyn Kiernan Title: Project Architect _ Phone: ( 781) 452-7121 Fax: (800) 866-0031 Email: rkiernan@phasezerodesign.com Property Owner Information Name 1810 Rinehart, LLC (Attn: Tomer Graziani _ Phone: (818) 331-4888 no Street: 6701 Franrivers Ave City, State Zip: West Hills, CA 91307 Resident of property?:. No _ Contractor Information Name Philco Construction (Attn: Matt Tomlinson) Phone: (407) 647-7445 Street: 114 N. Park Ave Fax: _ None City, State Zip: Sanford, FL 32771 State License No.:. CBC1260967 Architect/ Engineer Information Name: James Kimball Street: 35 Pond Park Rd, Bay 16 City, St, Zip: Hingham, MA 02043 Bonding Company: Address: Phone: ( 781) 452-7121 Fax: ( 800) 866-0031 E- mail: jkimball@phasezerodesign.com Mortgage Lender: _ 44 Business Capital Address: _ 1787 Sentry Parkway West, Bldg 16 Suite 200 Blue Bell, PA 19422 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 511' Egitioon(2014) Florida Building Code Revised: June 30, 2015 (0 — U r F C — )Lv l i() Permit Application G vc. it I S 11 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water managernent districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoqmg. 04/04/2018 i Signature of Owner/Agent Date ignature of Contractor/Agent Date James R. Kimball (Agent) print Owner/Agent's Name l Signature of Notary -State of Florida Date Stephanie S. Cushman NOTARY PUBLIC STATE OF FLORIDA Comm# GG 158657 E 1 Expires 11/7/2021 Owner/Agent is Personally Kn wn to Me or Produced ID Type of ID rz I *+t.J / W / Print Conhactor/Agent's Name W oLl I us bol ignature of Notary -State of Florida Date Stephanie S. Cushman NOTARY PUBLIC a-./ cIa"Y STATE OF FLORIDA Comm#GG158657 Ex Tres 11/7/2021 Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Flood Zone: of Stories: Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: COMMENTS: FIRE: BUILDING: J--" —fc' Revised: June 30, 2015 permit Application INSPECTION SEQUENCE BP# 18-1702 ADDRESS: 1810 Rinehart Road BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Slab / Mono Slab Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In 10 Frame Insulation Rough Firewall Screw Pattern 20 Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com'l) Building Ceiling Grid Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence Final Commercial — 1000 Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) ELECTRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough 10 Electric Rough Pre -Power Final Temporary Pole 1000 Electric Final OWNa Min Max Inspection Description 10 Rough Plumb Plumbing Underground Plumbing 2°d Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough 10 Plumbing Final MEC IXICAL PERMIT Min Max Inspection Description 10 Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap 1000 Mechanical Final REVISED: June 2014 COUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 18100002 DATE: March 20, 2018 BUILDING APPLICATION #: 18-10000286 BUILDING PERMIT NUMBER: 18-10000286 UNIT ADDRESS: RINEHART ROAD 1810 29-19-30-512-0000-0010 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: 1810 RINEHART LLC ADDRESS: 6701 FRANRIVERS AVE WEST HILLS CA 91307 LAND USE: TRAMPOLINE PARK TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 1810 RINEHART ROAD / CHANGE FROM <50K RETAIL TO MULTIPURPOSE RECREATIONAL / HH FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUE TYPE DIST SCHED RATE UNITS TYPE ROADS-ARTERIALS N/A ROADS -COLLECTORS N/A 00 FIRE RESCUE N/A 00 LIBRARY N/A 00 SCHOOLS N/A 00 PARKS N/A 00 LAW ENFORCE N/A 00 DRAINAGE N/A 00 AMOUNT DUE .00 PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE DATE ABOVE BUT NO LATER THAN CERTIFICATE OF OCCUPAkY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE BUSINESS OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT ISSUED WITHIN 60 CALENDAR DAYS FROM THE DATE ABOVE CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION 7 0ApplicationNo: '2 Documented Construction Value: $503,953.00 Job Address: 1810 Rinehart Rd., Sanford, FL 32771 Historic District: Yes El No FRI Parcel ID: 29-19-30-512-0000-0010 Residential El Commercial V1 Type of Work: New El Addition E] Alteration F1 Repair El Demo El Change of Use El Move LJ Description of Work: Interior alterations for fit out of an indoor trampoline park. Scope of work includes new restrooms/plumbing fixtures, interior walls and doors, electrical, mechanical, and structural which includes a raised mptal -,fijrJqpd plMnnrl pinfform Plan Review Contact Person: Robyn Kiernan Title:. Project Architect Phone: (781) 452-7121 Fax: (800) 866-0031 Email: rkiernan(o)-phasezerodesign.com Property Owner Information a Name 1810 Rinehart, LLC (Attn: Tomer Graziani)— Phone: (818) 331-4888 f, T_ 11 1 31 S. Street: 6701 Franrivers Ave Resident of property? : No U-6 City, State Zip:. West Hills, CA 91307 Contractor Information Name Philco Construction (Attn: Matt Tomlinson) Phone: (407) 647-7445 Street: 114N.Park Ave Fax: None City, State Zip: Sanford, FL 32771 State License No.: CBC1260967 Architect/Engineer Information Name: James Kimball Street:, 35 Pond Park Rd, Bay 16 City, St, Zip: -Hingharn, MA 02043 Bonding Company: Address: Phone: - (781) 452-7121 Fax: (800) 866-0031 E-mail: jkimball@phasezerodesign.com Mortgage Lender: - 44 Business Capital Address: _!Z§Z Sentry Parkway West, Bldg 16 Suite 200 Blue Bell, PA 19422 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, beaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30,2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and z ing. 04/04/201$ 1 Signature of Owner/Agent Date tIgnature of Contractor/Agent Date James R. Kimball (Agent) f;CMeMI9rJ y 5 % Print Owner/Agent's Name Print Contractor/Agent's Name H lJ UWhl-na h ou Ic51DO4 Signature of Notary -State of Florida Date Stephanie S. Cushman NOTARY PUBLIC STATE OF FLORIDA w Comm# GG158657 E 191 Expires 11/7/2021 Owner/Agent is Personally Kn wn to Me or Produced ID Type of ID oLl I as la()i' Signature of Notary -State of Florida Date Stephanie S. Cushman NOTARY PUBLIC a_ STATE OF FLORIDA p Comm# GG158657 SINCE 19-A% Ex Tres 11/712021 Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps, Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: lPt UTILITIES: ENGINEERING: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: COMMENTS: No ZO,;!nl (._ t t{ I ; Revised: June 30, 2015 Permit Application CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: - Documented Construction Value: $ $503,953.00 Job Address: 1810 Rinehart Rd., Sanford, FL 32771 Historic District: Yes No[]X. Parcel ID: _ 29-19-30-512-0000-0010 Residential Commercial Q Type of Work: New Addition Alteration © Repair Demo Change of Use © Move U Description of Work: Interior alterations for fit out of an indoor trampoline park. Scope of work includes new restrooms/plumbing fixtures, interior walls and doors, electrical, mechanical, and structural which includes a raised Metalghui and plmantiplaffnrm Plan Review Contact Person: Robyn Kiernan Title: Proiect Architect _ Phone: ( 781) 452-7121 Fax: (800) 866-0031 _ Email: rkiernan ,phasezerodesign.com Property Owner Information Name 1810 Rinehart, LLC (Attn: Tomer Graziani) _ Phone: (818) 331-4888 Street: 6701 Franrivers Ave City, State Zip: _ West Hills, CA 91307 Resident of property? :. No _ Contractor Information Name Philco Construction (Attn: Matt Tomlinson) Phone: (407) 647-7445 Street: 114 N. Park Ave Fax: None City, State Zip: Sanford FL 32771 State License No.: , CBC1260967 Architect/ Engineer Information Name: James Kimball Street: 35 Pond Park Rd, Bay 16 City, St, Zip: Hingham, MA 02043 Bonding Company: Address: Phone: ( 781) 452-7121 Fax: 800 866-0031 E- mail: lkimball@phasezerodesign.com Mortgage Lender: - 44 Business Capital Address: 1787 Sentry Parkway West, Bld;l 16 Suite 200 Blue Bell, PA 19422 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 10.5.3 Shall be inscribed with the date of application and the code in effect as of that date: 5th Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and z ing. 04/04/201 s 4 Signature of Owner/Agent Date tgnature of Contractor/Agent Date James R. Kimball (Agent) 2t+ a 8c4rnl9rQ -- 1F Print Owner/Agent's Name Print Contractor/Agent's Name VO_* .cnlJ 12tna, oy Ivs laolr Signature of Notary -State of Florida Date VIRStephanie S. Cushman NOTARY PUBLIC STATE OF FLORIDA Comm# GGIS8657 Expires 11/7/2021 Owner/Agent is Personally K wn to Me or Produced ID _ Type of ID Signature of Notary -State of Florida Date S.RY Stephanie S. Cushman NOTARY PUBLIC STATE OF FLORIDA w = Comm#GGt58657 SVNCE ties@ Ex ire$ 11/7/2021 Contractor/Agent is Personally Known to Me or Produced ID Type of ID _ BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[-] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: FIRE:! BUILDING: Revised: June 30, 2015 Permit Application 4Y F god CITY OF SANFORD 130 LDING & FIRE PREVENTION L3 PERMIT APPLICATION Application No: _) $ 7 02 Documented Construction Value: $ $503,953.00 Job Address: 1810 Rinehart Rd., Sanford, FL 32771 Historic District: Yes No 0 Parcel ID: _ 29-19-30-512-0000-0010 Residential Commercial 0 Type of Work: New Addition Alteration 0 Repair Demo Change of Use Move LJ Description of Work: Interior alterations for fit out of an indoor trampoline park. Scope of work includes new restrooms/plumbing fixtures, interior walls and doors, electrical, mechanical, and structural which includes a raised t,ql t,jd d plMnnrl platform0rs-r.aL.czu.t4,t andrwa Fu}r uea.n n r I Plan Review Contact Person: Robyn Kiernan Title:, Project Architect _ Phone: (781) 452-7121 Fax: (800) 866-0031 Email:. rkiernan@phasezeroy esi n.com Property Owner Informations, 1 Name 1810 Rinehart, LLC (A tn: Tomer Graziani) Phone: (818) 331-4888, Street: 6701 Franrivers Ave Resident of property?:. No _ City, State Zip:. west Hills, CA 91307 Contractor Information Name Philco Construction (Attn: Matt Tomlinson) Phone: (407) 647-7445 Street: 114 N. Park Ave Fax: _ None City, State Zip: Sanford FL 32771 State License No.: CBC1260967 Arch itectlEngineer Information Name: James Kimball Phone: (781) 452-7121 Street: 35 Pond Park Rd, Bay 16 Fax: (800) 866-0031 City, St, Zip: Hingham, MA 02043 E-mail: jkimball@phasezerodesign.com Bonding Company: Address: Mortgage Lender: - 44 Business Capital Address: 1787 Sentry Parkway West, Bldg 16 Suite 200 Blue Bell, PA 19422 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAI' RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and z ing. 04/04/2018 M Signature of Owner/Agent Date ignature of Contractor/Agent Date James R. Kimball (Agent) Print Owner/Agent's Name klcx,vt-V ID Bohr w..r) oy Its 1 DOIk Signature of Notary -State of Florida Date TStephanie S. Cushman NOTARY PUBLIC STATE OF FLORIDA w ? Comm# GG158657 1Q,f lO Expires 11/7/2021 Owner/Agent is Personally Kn wn to Me or Produced ID Type of ID Print Contractor/Agent's Name-- ku10 of I cis bc)18 Signature of Notary -State of Florida Date Stephanie S. Cushman NOTARY PUBLIC STATE OF FLORIDA w, Gomm# GG158657 wet 191 Ex ires 11/7/2021 Contractor/Agent is Personally Known to Me or Produced ID Type of ID _ BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: WASTEWATER: FIRE: BUILDING: Revised: June 30, 2015 Permit Application CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION FIRE PLAN REVIEW SERVICE FEES PHONE: 407.688.5052 FAX: 407.688.5051 I m7 n DATE: /, /I BUSINESS/PROJECT NAME: ADDRESS: / r/ 0 /, ft, CONTACT NAME: PERMIT NUMBER: PHONE: K — -,70 PLAN REVIEW INFORMATION m/CONSTRUCTION []C/O [] FIRE ALARM [] FIRE SPRINKLER []HOOD [ ]PAINT BOOTH []TANK DOES 20Yo REDUCTION IN FIRE IMPACT FEES APPLY: YES NO TOTAL FEES: A AIA Document A101'" - 2007 Standard Form of A meme of Payment is a Stipulat Sum am AGREEMENT made as of the 21 day, of March in the year 2018 Or; '*Qr(4N, indicate dq),', tricuilh amiyear BETWEEN the Owner: e'"'e. 10901,vtaftoi, addre akul other it!fbrmatior) JUMP 2018 LLC 1010 8 EvrTgreen Lane Drive Tdmpay Ft. 33647 and the Ccwutracjor: Volrw, i&evs uml other iolormatioeti Ph lee C(kn'struction De% elopnicrit 114 NN Park Ave Sanford, FL 327771 for the following, projecu A`0— location and delailed deswriptionj Attitude, Trampoline [lark, 1810 Rinehart Road, Saarord Fj- 32771 Renovation of 111-10REG into Attitude Trampoline Vark The Architeta: ame, legal wan,", a&ircss andotherr io(bowatiottl Phase Zero Design 35 Pond Park Road, Bay 6 Hinghtim,MA 02043 Vhe Owner aid (7ontractor agree as follows, ADDITION$ AND DEL*VIX", The allthOf of this document has added InforMatiol needed for its Completion. The author may also have revised the text of the original AIA Standard form. An A*Vftn4 and Oei*W(rs Report that notes added information as w(iji as revisions to the standard form text Is avaltat)le from the author and Should W reviewed. A vertfi.al line in the left margin Of INS do wment indicates Where the author has added rleCessary Information and where the author has added to or deleted from it* 069inalAIA text, This document hats important "I Consequences. Consultation with an attorney is encouraged with respect to as completion of modification, AIA Document xzai --2007, General Conditions of the Contract for Construction, is adopted In INS document by r0crence, 00 not use With Of generril conditions unfo$$ this document is modified, 1987,1991, 1907 Orld 2007 by The Am*r1cqetuftInstituteofAmNiscb. All right* reserved, WARNWG: This A(A* Deaunwot to pro by US. Copydqj't Low 400 I"(*m0wool Tr"tloc urkauthodjed r*productlOn of dtaft"Ibu"n of thle AIA10 Documoat, at any portion of 4, may result In S#vW* q;" and trurliftl poulbq*, and wal b* pro4sKut" to thomaximumoxtent, po"(Wo under " low. TW document was produoed by AtA ra at I & jqtj I on 0=1120111 under Order No, 8196731374 wttich oxpir" on 03/211'2019, and is not for rewe, User Naft*z (389ADA23) TABLE OF ARTICLES I THE CONTRACT DOCUMENTS 2 THE WORK Of THIS CONTRACT 3 DATE OF COMMENCEMENT AND SUBSTANTIAL COMPLETION 4 CONTRACT SUM 5 PAYMENTS f DISPUTE RESOLUTION 7 TERMINATION OR SUSPENSION 8 MISCELLANEOUS PROVISIONS 9 ENUMERATION Of CONTRACT DOCUMENTS 10 INSURANCE AND BONDS ARTICLE I THE CONTRACT DOCUMENTS ne Contract Documents consist of Conditions of the Contract (Genem 1, Supplementary and other Conditions), Drzovings, Spcc i ilicat ions. Addenda issued prior to execution of this Agreerner1% other documents listed in this Agreement and %I(Aifications i su d atler cxccUfion ot,thi, kgrement, all of which form the Contract, and are as fully a pan ofthe contract as it attached to this A urecnlent or repeated herein, The Contract represents the entire and integrated representations or gratedagreementbetweenthepartiesherttoandsupersedQ-, prior negotiations, agrements, either writ , lenororalAn e;j u III eration of the Contract Documents, other than a Modification, appears in Article 9. ARTICLE 2 THE WORK Of THIS CONTRACT The Contractor $hall full} execute the Work dcscrib ed in the Contract Documents, except as specifically indicated in the Contract rXicurntnti to he the of othcns. ARTICLE 3 DATE OF COMMENCEMENT AND SUaSTANTIAL COMPLETION 31 The date of coma ens ernefit Ofthc Work shall be the date of this Agreement unless a different date is stated below, or provision is rnade for the date to Ic fixed it, zj notice to proeccd issued by the Owner. Insert the da teqf it dq ers frorn the date o this Agreement or, If applicable, state that the date will beli.,rstj in a notice to proceed i it, prior to the commencement of the Work" the Owner requires time to file mortgages and other security interests, the Owner's time requirement steal I be as follows: 3, 2,The Contract Time shall be measured from the date of commencement. 3. 3 The Contractor shall achieve Substantial Completion of the entire Work not later than ( )days from the date of commencement, or as follows: with the date of qartrt numher of calendar days. Alternatively, a calendar date may be used when coordinated at or earliet-Substantial Completion Of certain POrtlons of the commencement, #apnroariate, insert requirementsfi 1- Work) 60 IMP 1974, 1977, 1987, 1991, 1997 and 2007 by The American AJA D( Kwr4rKAIaI--MT.00PY69hA*19I5, riilii, 1925, 1937,1$61' 1954' 196" 1963, no international I'mati". U"authortzad 2 Enit 1, 44tut, of Aschibeebi, AR dgtft ie"mao, YARNING: This AIA* Docuni*nt Is PrQ1*et*d by U1, cafhoight Law a bis ad wil be pmx*e&Aad W the nipmducuoo or insuftwoon of this AtA* OocmaWts, Of any P0410" Of IL may mutt in *"Or* z'" and criminal P*"Af " 1 3 which maximum extentpo"flefit ondet the law, This documorawss PmdurOO by AIA Software at 15:19:1 Ion oWi12018 wtd*rO((W No, 01967 1378 oxpkes on 0312112019, and is not tar fs*414. (389ADA23) user Nobew Portion of Work Substantial Completion Daft subject to adjustments of this Contract Time as provided in the Contract Documents. Insert provisions, ifan)', fir liquidated damages relatiaq tofadure to achieve Substantlat Completion on time orfor Norms pa} mentsfar early, completion of the Work) ARTICLE 4 41 The er shall pay the , a char the Contract Sum in current funds for the Contractor's performance of the Cont , The Contract Sum ill, be Six I-lundred'I'wenty-three Thousand One Hundred Ninety Dollars and Zero Ccn ($ 62-1,190,00),su'ec 0 Additionsaliddeductionsas provided in the Contract Documents. 4 The Contract Sum '—, ed upon the floilowing alternates, if any, which are described in the Contract Do, Q e is and are , -by accepted bG the 0\8ner. State the or other idenil,ffe«tion alleroates if the bidding or proposal documents permit the OWner to accept other altcrnatas subse"llient to the execution of this,4greement, atrach a sched"It! of $11ch Other alternates the amounifif"Ir each and th(" date when that amount exphv v Exhibit E (lint items and qualificatiorts) 4. 3 Unit prices, if any-, atki state Ike unit price, qticlojill, lijoilitions, 4'ako,, to which toe, Inot price will Ite applicablej Item Units and Limitations Price Per Unit ($040) 4. 4 Allowances included in the Contract Sun', if rein I Ick- arl'4" all"ru'unce and state exclusions, tJ'anlv ''firom the allott ance Price) lum 00 ARTICLE 5 PAYMENTS 5. 1 PROGRESS PAYMENTS 5, 11 Based upon Applications ibr PAy Rlent ,ut)m itted to tire Architect by the Contractor and Certificates for Payment issued by the ArchitoCL, the Owner shall make progress payments oil account of the Contract Sum to the Contractor as provided below and Osewhere it, the ('ontract riocuments. 512 The period covered by each Application for Payrnent shall be one calendar month ending on the last day Of the month, or as follows: 51. 3 Provided that ail Application for Payment is received by the Architect not later than the 20th day Of a mouth, the Owner shall make payment of the certified amount to the Contractor not later than the 10th day of the following month. If an Application for Payment is received by the Architect after the application date fixed above. payment shall be made by the Owner not later than thirty ( 30 ) days after the Architect receives the Application for Payment. t' edvral, state or local laws may require payment within a certain [wriod of time,) 6. 1.4 Each Application for Payment shall be based on the most recent schedule of values submitted by the Contractor in accordance with the Contract Documents. Tate schedule of values shall allocate the entire Contract Sum among the various portions of the Work. The schedule of values shall he prepared in such form and supported AtA Docw"ntA101--"Q7,C*PY09raQ 1915- 1918,1025,1037, 1961,1968, 1961, 1983,1967, 1974,1977, 1081, 1991, 1997 and 2007 by The AmettclIn lrotate of Atchqe,,%, All right* (0004v4d. VVARKRIGThis AJA* O"u~t is PrOt*lt" toy U,S, COPY6911t LAw *t%ti totem atioosl Treaties. Unauth9rizad 3 roprodttetion or dkSlobtalon of this AA* VocumOnt, Of SOY P0414" of it. "y M*uh to ##"m cha OW crhWost pwnxlfi**, 2ftd will be pf***cVW to the rnowimum #Xtgot " iblq t4nder hero tew. Thisdocunwt was PMOUCOd t y AIA soft"(* at 15:1901 I On Mit2ollt uallSsordaf Nil6196T31378 which expims on OW112,019 and Is not re"S, (380ADA23) U**r NOW, C by such data to substantiate its accuracy as the Architect may require. This schedule, unless objected to by theArchitect, shall be used as a is for reviewing the Contractor's Applications for Payment. 51,5 Applications for Payment shall show the Percentage of completion of each portion of the Work as of the end Of the Period covered by the Application for Payment, 5,1.6 Subject to other provisions of the Contract Documents, the amount of each progress payment shall he computed as follows: A Take that portion ofthe Contract Sum property allocable to completed Work as determined by multiplying the percentage completion of each portion ofthe Work by the share ofthe Contract Sum allocated to that portion of the Work in the schedule of values, less retainage often percent ( 10 %), Pending final determination of cost to the Owner of changes in the Work, amounts not in dispute shall be included its provided in Section 7.3,9 of AIA Document A20 ITIt-2007, General Conditions of the Contract for Construction; 2 Add that portion of the Contract Sum Properly allocable to friaterials and equipment delivered and suitablN stored at the site for subsequent incorporation in the completed construction (or, if approved in advance by the 0-ner, suitably stored offthe site at a location agreed upon in writing), less retainage of tell percent 3 Subtract the aggr",arc o , f previous payments made by the Owner; and 4 Subtract aroounts, if,,jily, for,,vtlich the Architect has withheld or nullified a Certificate for Payment as provided in Section 9 5 of NIA Document A201-200T 5A.7 Fhe pnigress paN ment anrourit determined in accordance with Section 5,1,6 shall he further modified under the following circuns,,tances: A Add, upon Suhstantial Cotnplction ofthe 4tork, a suni sufficient to increase the total payments to the full amount of, the Contract Sum, teis, such amounts as the Architect ,,hall determine for incomplete Work, rcrainagc cipplicabte to such work avid unsettled Claims: and eSection 9 8 5 IrWlirneni,1201 (f(f7 requires relcuse q1'applicabie retainage union Substantial Completion of Work with "ol'isvill of stlreo,,forty1 2 Add, if final cornpletion of the kkork is thereafter inaterially delayed through no fault of the Contractor, art) additional wtiount, pa,,ahle in accordance with Section 9, 10-3 of A[A Document A201-2007, 5.1.8 Reduction or limiuiucm cif retainage, if any, shall be its fsAklws: ail it is infended, iwior to substantial Cornpl,"von oll"the ntire lVork, to reduce or litnit the retainage resultingfira"i file f'),ercentages inserted in 'Sec-liou'v 5 1 6 1 ant 5 1, 6 : above, and this is not e,-rphafneil elsewhere in the Contract J),,)CrfMent,v invert /W" provisions fiws uch rethictiorr or limitation, i 5,11 Except with the Owner's Prior approval. the ('(infractor shall not make advance payments to suppliers for materiats or equipment which have no, been delivered and stored at the site, 5,2 FINAL PAYMENT 5.21 Final payment, constituting the entire unpaid balance ofthe Contract Sum, shall be made by the Owner to the Contractor when 1 the Cyanforhas fully performed the Contract except for the Contractor's responsibility to correct Work as provided in Section 1112 of A [A Document A201--2007, and to satisfy other requirements, if any, which extend beyond final payment; and I a final Certificate for Payment has been issued by the Architect, 5. 2.2 The Owner's final payment to the Contractor shall be made no later than 30 days after the issuance of the Architect' s final Certificate for Payment, or as follows: or to the Certificate of Occupancy being released J( L- 0* aum*ntA101--2Q07.C*PYr`t* 1016, n116, 1925, 1937% 1"1. 19b4, 1961, 1"3,1947,1$74,1977,1987,1991,19976rld2007bYThOAMSOCOn tttiG JrAthgs of Axlftcft. AN d9tft nkW"d-WARNING: Tb* At** 0QeUm*ft1tar Pf0UKWb)rU.3, Copyright t.Awoad (aftmAll"alTrVial", Unauthortz" 4 ropro4ucuan ordtiodbudonofthisAIA"' Oocumwnt, - Vq portion of K, may msuft to **vw* 1:Mt a crwmw P*414100*, and War bo V000CUwd to art maximum extant pa"R>10 w4w th* taw, In" domanent w** Mod000d by AIA *m%me fA I& lir I I on 03121M0I 8 wW*r Ordw No, 41"731370 while expit" gn 0W12019, and is riot for msee. U**r Nateit'. (389AGA23) ARTICLE 6 DISPUTE RESOLU11ON 61 INITIAL DECISION MAKER The Architect will serve as Initial Decision Maker pursuant to Section 15.2 of AIA Document A201-2007, unless the parties appoint below, another individual, not a party to this Agreement, to serve as Initial Decision Maker. If the parties mutualltagree, insert the narne, ac1dress and other contact information of the Initial Decision Maker, if other that? the Archaeco Jump 2018 LLC 10108 Evergreen Lane Drive Tampa, FL 33647 61 BINDING DISPUTE RESOLUTION For alIN Claim su icct to, but not resolved by, mediation pursuant to Section 153 of AtA Document A201-2007, the, method of binding dispute resolution shatt be as follwks: Check, the qpprc,-tpria1e /ox l 'Iih, Ou,ner and Contractor do not selecl a otelhod qf hinding dispute resolution k4aw, or do not su6sequentlyugree in it rititW to a hinding dispute resolution method other than litigation, Claims will be res('41va' lyY lifigalion in court ofcotripetew jurisdiction) Arbitration pursuant to Soctiori 15A of AIA Document A201--2007 X 3 Other 6'pec,6,1 See Exhibit D ARTICLE 7 TERMINATION OR SUSPENSION 7. 1 The Contract may be terminated hN the Ovoicr or the Contractorwis provided in ,Article 14 of AIA Document A201 - 2007, 7. 2 The Work ma) be suspended by the (;)wrier as provided uiArticie 14 of AIA Document A201-2007. ARTICLE 8 MISCELLANEOUS PROVISIONS 8. 1 Where reference is made in this Agreeilivit r() a provision of AIA Document A.10 1-2007 or another Contract Doeurnent, the reference refers to that provision as amended or supplemented by other provisions of the Contract Documents. J 8.2 payments due tuW unpaid under the Contract shalt hear interest front the date payment is due at the rate stated below, or in the absence thereof, at the iegal rate prcvar'jing from time to time at the place where the Project is located' lo, yert mate of interest agree.1 ittion, ifan v 15 % monthly 8. 3 The Owner's representative: Nrame, address and other information) Brian Dualeavy 4340 W. Will"rough Ave, Suite 350 Tampa, FL 33614 913- 939-89% IP- 8. 4 The Contractors representative: Name, address and other information) refrrveiue# nn or dtsufburian vi trite ASAP tt®eurrreett, an arty par tn of f mey nsutt Fn ewers cPtN Arad nrkrsttnaf etuMku, rnd wtif be prnsecutrfd kn the tJsM " OtM Brian Borman It 4 N Park, A,, Sanford, FL 32771 407-782-1871 8-5 Neither the Owner's nor the Contractors representative $hall he changed without ten days written notice to theotherparty, S 8,6 Other pwvisions: ARTICLES ENUMERATION OF CONTRACT DOCUMENTS 91 'The Contract Documents, esccpt f(jr 'vlodi ficatonsi the sectiotis below.issued 3fler execution Of this Agreement, are enumerated in 9A A The A,regiment is this cxocutcd A fA Document A 10 1- 2007, Standard Form of Agreement Between OwnerandContractor, 9-1-2Thc General Conditionsire AIA M)cklvuent A20 l -2007, General Conditions of the Contract for Construction, 9, 13"flyc SupplemejuaTN, and other j tire (,()njract: Document Title M 9. 1AT'he Specifications: Efther list here ()r refe" 1") aft exhibit eelicicitel to rats "lgreeownt, Section Title M j 9.1.5'Thc Drawmp; Either & vt the 1)rmving,s here refer to an cxhibi( attached to this Exhibit A, which will be a part of the contract documents once drawings are complete Number Title Date 91. 6 'Me Addenda, if any: Number Date Pages Portions of Addenda relating to bidding requirements are not Part Of the Contract Documents unless the bidding requirementsarealsoenumeratedinthisArticle9, 9. 1.7 Additional documents, if any, forming Pan Of the Contract Documents: A AIA Document E20ITt-2007, Digital Data Protocol Exhibit, i(compicted by the parties, or the following: P0 I F—A(T, AJA Omurn"t Al 0 1 MTCoPyAght 0 19 7-5. 1910, 1924, 1037, 196 1. 1 "S, I %al , 1963, 1967, 1 %r4' t 077, 1 get, 1991, 1997 40d 2W 0 Irttt InamteofArchAllrightsM"rved. WARG NVN: TWO AWDocu"wat is prowU.S. Ca t*d by bYThAMMIcanpy6ght Law And taternAU"* 1 Tnts0", Unauthorizail r*pmauctlon or distributionofthisALAIDocu"M or any Patna" of k amy r"Va in *aster* civil trot cro"t"al Poo**", end Win b* P 44*6 to the 6 nwWwro extentlft p0*41WO Under thetaw. Tdocument was PMdv0*d by AIA 00ft4f* at 1 5: 19:11 on 03121/2010 ur4ft Order No, 4j9sr3jM37*8*WC owyes on ast2irni9, and isnotforresatehousorNot": (399ADA23) pn Standard Change Order documents signed prior to additional work commen6rig. Other documents, if any, listed below: List here arn, additional doczlinerits that are ittlended to tort, P"I ( Of the Contract Vocllments, AAA Docteem ,4MI-MOI` provides that bildingrequirwrients such as advertisement or - invitation to bid to Bidders, sample )rats and the Contractor's bid are not part of the (contract Then should be listed here oiitv if intended to be, part oft Contract 0(wu,?tvnjv) Exhibit A (List of Drawingsionce completed), Exhibit U, Exhibit C, Exhibit D, Exhibit E (list of line iteniand qualifications) ARTICLE 10 INSURANCE AND BONDS The Con" ctor shall Purchase and maintain insurance and provide bonds as set forth in Article I I of AEA Document A201-1- 1007, State bee if clov, atut limits 0'1ia!oU(y'fiw insurance requireqf d in / I .4[4 Vocunwirt 4201 -2007 j ' I Type of fraurance or bond Limit of liability or bond amount ($0.00) written ittlove, Brian A 13ormart President ir,inted name and title) rn 016 ep halt Exhibit A List of Drawings 1810 Rinehart .. Sanford, GOOI 3/la/2018 ADIO . 3/12/2018 CHAPTER 558 NOTICE OF CLAIM THE PARTIES HEREBY AGREE 'I'fJAT THE PROVISIONS OF CHAPTER 558, FLORIDA STATUTES SHALL BE DEEMED TO BE A PART OF THIS AGREEMENT, CHAPTER 558, FLOKIDA STATUTES., CONTAINS tiMPORTANT REQUIRENIENTS YOU MUST FOLLOW BEFORF. YOU MAY BRtNG ANY L.FGAI- ACTION FOR AN ALLEGED CONSTRUCTION DEFECT. SIXTY DAYS til"FORE YOtl BRING ANY LEGAL ACTION, YOU MUST DELIVER TO THE ()THER PARI'Y TO THIS CONTRACT A WRITTEN NOTICE, REFF'RRING TO CHAPTER 558, OF ANY CONSTRIX-I-ION CONDITIONS YOU AI -LE GE ARE DEFECTIVE AND PROVIDE SUCH PERSON' THE, OPPOR"11JINITY TO INSPECT THE ALLEGED COONSRJ(A R)N 1,A.",J-k"I'S AND TO CONSIDER MAKING AN OFFER TO RI;PAIR OR PAY FOR IT -IL ALA,EGED CONSTRUCTION DLFI'-C" l"S, YOU ARE NOT 0111,1GATI-I'D 1-0 ACCEPTANY OFFER WHICH MAYBE )MADE. ARl" STRIC"T DEADLINES AND PROCEDURES UNDER THIS FLORIDA I-AW BE LIVIETAND FOLLOWED TO PROTECTYOUR IN VERFSTS. M-30 In the event that any govemmental body or other regulatory agency imposes any additional requiTements on the construction of subject improvements, costs of same shall be home by Ow-ner. In the event that Contractor is made aware of any such additional requirement, then Contractor shall promptly notify Owner in writing of any such additional requirements and estimated cost thereof, and afford the Owner an opportunity to discuss the additional requirements Nvith the authority havingjurisdiction. Hidden Conditions: Should Contractor encounter hiddet, ()r urrL,11()vn coo(,jitions, all cost of such conditions shall be tx)me by Oxner, Contractor aurecs to pr(),uptly report any conditions to owner and work in a manner as to not dcla-y the progress of the work if possible, MEMM DISPUTE RESOLUTION: All relFerenccs to Arbitration in this contract are hereby deemed mmoved and void Ile parties agree that they shall not resolve disputes by Arbitration, As a condition pre dent to the Wing of any, suit or other legal proccediii, the parties shall endeavor to resole - cl,,jitris, P (ji-S UteS or other masers in question by mediation. Mediation shall he initiated by any party by sening a "hum request tier same on the other party, The parties hall, bY mutual a,-JeeWeM Sect a mechatm- "Ithn Ofteen 0 5) days of the date of the request Q rnedimion. if the Paris varaus agme on we scoomn nr a mediator, ten Um Untruixii- shall select the Mediauu who. if seleacd solely by he Commoor, shall be a wrediator certified by the Suprerric Court of Fkmid& NO sub or odwr legal proceeding shall be filed until the meWamr declares an Spam, which Wlarution, in any event, shall be issued by the mediator not later than sixty the initial uiediation cont'crence, A ITORNFVS f,'ELS: h, Ow MM thm cidwr pa) suks to ent'orce this Contract by way of1"-al action, and flne inatter is placal in the hmd"Wan attorney, that the prevailing party shall rccover its atUanns' thew mid to court shall domnine we mn()unt ()f such fees and allow re"Wmi to said pre\,ailing, parzy in Mitmmg a jlldgluetu The parties agTcc that entitternent to Wonwyl kcs bOIC PrCifling JMQ LGI&I this Agreeniew shAl be deemed to inducle all appellate atiorneysf'ees, 4101111b 4 IV Exhibit E 1111111 111111ir11v PROJECT: Altitude Trampoline Park LOCATION: 1810 Rinehart RD DATE: 03108118 17IIITION TOTAL DESCRIPI BID 71i COST liil II 000 GENERAL I r wy F uildejrs Risk Insure Earthwo Soil Poisoning e6ar- y Owner ly Owner ly Owner ly Owner ly Owner ON A4016. 4 IV I IN N, I tivtl" I"( IIIM Nt PROJECT, Attitude Trampoline Park LOCATIOW 1810 Rinehart RD DATE: 03108118 MEELOMME01= BID COST TOTAL MASONWX Structural Steel Vetal Building (Labor) 000 CARPE TRY lFraming I DoMall Flooring 11000EOUIPI w AAW1111, 111H9111 PROJECT: Attitude Trampoline Pau LOCATIOW 1810 Rinehart RD DATE: 03/08118 1 ZMMEGM+ i i i IIII TOTAL DESCRIPTION BID COST III I NNI MIN III Ill lumbing IFire SprinklerII J r' ul I IIIIIIIIIIitIIII IIIIIIIII IlliN I I+ IIIIIIIIII I WAW zm Please see Quailffications tefow — Paintediepoxy concrete floor with colored flaked add... $11.360 If re room partitions are required (Powder coated steel) add... S2,000/restroom If handrails are required to be galvanized add... $ 1 5/L F Structural Root' Underground utilities Parking lot modifications rhis pro -t( drawing, noposalisbasedoffol'a conceptLi, Jr, bid plans provided. Carpet for decking to be Furnished by others. Reception/cOncession t-fliftwOrk included. All other rnillwork-, tables, counter tops, chairs, andJor fitimiturc to be provided by others. Refrigerators. freezers, soda machines, icee machines, ice machines, tv's, phones, computers and all otber equ ipment by others, event" stations by others Asbcstos survey andJor removal. Permit Number IS-1413 of Sanford Parcel 10"bification Number n-19-30-512-0000-001,11) Prepared by: "Myonwomw 114 N Pert Ave sm"fo, K 32771 Return tw PWk* C*,4WWM*ff WW 0W.WkMWAftt UC 114 N VW% Are sonhilo vt IZ771 NOTICE OF COMMENCEMENT State of Rod" County Of sovkh"All I 6it %Cd DT Li IT 0WRT CLERK'$ 2018032853 1ING FEF-S, L CGY li&ivoi,c. The undersOvd hereby gives nooks that Imptvvements will be male to certain r" property, and In 8cW%V4e with Chapter 713, Florida Statutes, the foll1amn m(Ormabort Is provided in this Notice of Commencement 01- Description of property (leo description of the property, and street address It available) LOT I Street Address SEMlNW COMMONS Ifto PJMWawt R4, ft!" Ft. 32771 Pe so PGS a & 9 02, General description of improvemengs) INTERIOR BUILD OUT FOR TRAMPOUM11 PARK 01 Owner Wftrmation Name 1810 RIN11"ART LLC Telephone Number AdOess AVE Fax Number Uff Interest In Property OWNIM 04, Fee SWn0le Tit* Hokler (if other Ow the owner shown aba4e) Nam Telephone Number Address Fax Number 05, Name PhUDO Constradon and Owel. LLC Telephone Number 407-782-1871 Addre" 114-HPAW-0-1- Fax Number go— MIQ K 06- Surety (if any) Name Telephone Number Address Fax Number Amount of bond 07- Lender (W any) NO" Telephone Number Address Fax Number 06. Persons within the State of Florida deWWwW by owner upon whom notim or other documents may be served as provided by Section713.13(1Xa)7, Florida Statutes. Rome Phiko Conseruction MW Owell, LLC Telephone Number 407-782-1971 Address 114 Ot AW — Fax Number 09. In adlWon to himself or herself, Owner 4esoiates ft follow" to racewe & copy of the Umnor's Notice as provided by Section71113(1)(b), Florida Statutes. Name Telephone Number Address Fax Number 10, EXWWW date of noficeo(commencerrWK(the expiration date ISO" year from the date of Curless 12Yfer4mt date is specillecl): WARMNG TO OWNER: ANY PAYMM HAVE By THE OWMW AMR THE 6MRAITOW OF THE WrXZ Of MOBINCEMW ARE 00" UMIRS0 000MR PAYMMS ONIM OLWTEE 71X PART 1, $11ICTION7=41, Ft MOA STATUTES, AMP CAN UWLT W YOUR PAYMTv"M Joe SITear" INOMM4011M TO YOUR P"PINTY, A NOTICE OF W""11102KORr MW BE 0000010 AXO, POSTED 0" THE TFlW WSPECTWOL If YOU INT9010 TO OBTAIN Pl"A"C"00, COM&T WITH YOM WHIM OR AN ATTORNEY affonWORKoftRECOROMSYOURNOTICEOFcommitNCEWW. WWWO RI W. M -AW TAYLOR P" ft, $we of TRH Comm. EXPfros 02-22-2= BP " Ok y .wFR1 RF1 A ore t bare rho eM anti drat d+e laces jai a, P~M nCQMcheck Software Version 4.0.8.1 Interior Lighting Compliance Certificate Project Information Energy Code: 2017 Florida Building Code, Energy Conservation Project Title: Altitude Trampoline Park F 'ICEProjectType: Alteration o Construction Site: Owner/Agent: Designer/Contractor: 1810 RINEHART ROAD JUMP 2018 LLC DON PENN SANFORD, FL 10108 EVERGREEN LANE DRIVE DPCE TAMPA, FL 33647 1301 SOLANA BLVD 813) 838 8896 BLDG 1 SUITE 1420 WESTLAKE, TX 76262 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts f:2) Watts / ft2 B X C) 1-PLAY AREA (Gymnasium/Fitness Center: Playing Area) 27753 1.20 33304 2-LOADING DOCL (Common Space Types:Loading Dock): Exempt 3-RR (Common Space Types:Restrooms): Exempt 4-OFFICES (Common Space Types: Lounge/Breakroom) 438 0.73 320 5-STORAGE (Warehouse:Medium/Bulky/Pallet Material Storage) 1000 0.58 580 Total Allowed Watts = 34203 Area Category Exemption Qualifications Fixtures Total # Watts Activity Area Pre -Alt. Repl./Added Pre -Alt. Post -Alt. LOADING DOCi ( Common Space Types1oadhg Dock 4 1063 sn.ft.) 0 308,000 308.000 Exemption: Less than 10% fixture replacement. RR ( Common Space Types Restrooms 576 sa ft) 6 0 924.000 924.000 Exemption: Less than 10% fixture replacement. Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ of Fixture (C X D) Fixture Fixtures Waft. PLAY AREA (Gymnasium/Fitness CenterPlaying Area 27753 sg ft) LED 1: TYPE B/B-EM: GENERAL FLOOR LIGHTS: Other: 1 47 160 7520 HID 1: TYPE EX: GENERAL FLOOR LIGHTING: Metal Halide: Standard: 1 55 350 19250 LOADING DOCL (Common Space Types1oad4no Dock 1063 sg ft) Exempt Linear Fluorescent copy 1: TYPE EX: EXISTING LIGHTING: 48" T8 32W: Magnetic: RR Common 2 4 77 308 Space Types•RestroomG 576 sg ft): Exempt Linear Fluorescent copy 2: TYPE EX: EXISTING LIGHTING: 48" T8 32W: Magnetic: OFFICES 2 6 77 462 Common Space Types1ounge/Breakroom 438s.fL) Linear Fluorescent: TYPE A/A-EM: GENERAL FLOOR LIGHTS: 48" T8 32W: Magnetic: 3 5 96 480 STORAGE ( Warehouse•Medium/Bulky/PalletMaterial Storage 1000sgft ) LED 1 copy 2: TYPE B/B-EM: GENERAL FLOOR LIGHTS: Other: 1 3 160 480 Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3_Construction Documents\3.4 Energy Page 1 of 6 Compliance\PZD18005 Altitude Sanford FL.cck Interior Lighting Compliance Statement = -v Compliance Statement. The proposed interior lighting iq building plans, specifications, and other calculations su%xr systems have been designed to meet the 2017 Florida E4 4.0.8.1 and to comply with any applicable mandatory regd DON PENN. P.E. Name - Title Siam Total Proposed Watts = 27730 this document is consistent with the ion. The proposed interior lighting ion requirements in CQMcheck Version ion Checklist. 04/04/18 Date Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3_Construction Documents\3.4_Energy Page 2 of 6 Compliance\PZD18005 Altitude Sanford FL.cck 6 COMcheck Software Version 4.0.8.1 IS( Inspection Checklist Energy Code: 2017 Florida Building Code, Energy Conservation Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section I Plan Review Complies? Comments/Assumptions C405.6 Plans, specifications, and/or Complies PR17)1 calculations provide all information Does Not with which compliance can be determined for the electrical systems Not Observable and equipment and document where Not Applicable exceptions are claimed. Provisions are made for metering individual tenant units. Feeder connectors (for feeder and branch circuits) sized in accordance with approved plans with maximum drop of 5% voltage drop total. C103.2 PR4)1 Plans, specifications, and/or Complies calculations provide all information Does Not with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: Not Observable Not Applicable 1 High Impact (Tier 1)2 1 Medium Impact (Tier 2) 3 !Low Impact (Tier 3) j Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3_Construction Documents\3.4_Energy Page 3 of 6 Compliance\PZD18005 Altitude Sanford FL.cck Section Rough -in Electrical inspection Complies? Comments/Assumptions Re .ID C405.2.1 Lighting controls installed to uniformly Complies EL1511 reduce the lighting load by at least Does Not 50%. Not Observable Not Applicable C405.2.1 Occupancy sensors installed in Complies EL1811 required spaces. Does Not Not Observable Not Applicable C405.2.1, Independent lighting controls installed Complies C405.2,2.; per approved lighting plans and all Does Not 3 EL2312 manual controls readily accessible and visible to occupants. Not Observable Not Applicable C405.2.2. Automatic controls to shut off all mplies 1 building lighting installed in all Does Not EL2212 buildings. Not Observable Not Applicable 6405.'i3 Daylight zones provided with Complies EL1612 individual controls that control the Does Not lights independent of general area lighting. Not Observable Not Applicable C405.2.3, Primary sidelighted areas are Complies C405.2.3. equipped with required lighting Does Not 1, C405.2.3. controls. Not Observable 2 Not Applicable EL20J1 C405.2.3, Enclosed spaces with daylight area Complies C405.2.3. under skylights and rooftop monitors Does Not 1, C405.2.3. are equipped with required lighting controls. Not Observable 3 Not Applicable EL21J1 C405.2.4 Separate lighting control devices for Complies EL411 specific uses installed per approved Does Not lighting plans. Not Observable Not Applicable C405.2.4 Additional interior lighting power Complies EL811 allowed for special functions per the Does Not approved lighting plans and is automatically controlled and Not Observable separated from general lighting. Not Applicable C405.3 Exit signs do not exceed 5 watts per Complies EL611 face. Does Not Not Observable Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3 Construction Documents\3.4 Energy Page 4 of 6 Compliance\PZD18005 Altitude Sanford FL.cck Section Final Inspection Complies? Comments/Assumptions ix Req.it 6303.3, Furnished O&M instructions for Complies C408.2.5. systems and equipment to the Does Not 2 FI17]3 building owner or designated representative. Not Observable Not Applicable C405.4.1 Interior installed lamp and fixture Complies See the Interior Lighting fixture schedule for values. FI18]1 lighting power is consistent with what Does Not is shown on the approved lighting plans, demonstrating proposed watts Not Observable are less than or equal to allowed Not Applicable C408.2.5. Furnished as -built drawings for Complies 1 electric power systems within 90 days Does Not FI16]3 of system acceptance. Not Observable Not Applicable C408.3 Lighting systems have been tested to Complies FI33]1 ensure proper calibration, adjustment, Does Not programming, and operation. Not Observable Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3_Construction Documents\3.4_Energy Page 5 of 6 Compliance\PZD18005 Altitude Sanford FL.cck Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3_Construction Documents\3.4_Energy Page 6 of 6 Compliance\PZD18005 Altitude Sanford FL.cck Software Version 4.0.8.1 86COMcheck1 Interior Lighting Compliance Certificate Project Information Energy Code: 2017 Florida Building Code, Energy Conservation 1"k v1 ls; Project Title: Altitude Trampoline Park' Project Type: Alteration` 0. 3 Construction Site: Owner/Agent: Designer/Contractor: 1810 RINEHART ROAD JUMP 2018 LLC DON PENN SANFORD, FL 10108 EVERGREEN LANE DRIVE DPCE TAMPA, FL 33647 1301 SOLANA BLVD 813) 838 8896 BLDG 1 SUITE 1420 WESTLAKE, TX 76262 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts ft2) Watts / ft2 B X C) 1-PLAY AREA (Gymnasium/Fitness Center:Playing Area) 27753 1.20 33304 2-LOADING DOCL (Common Space Types:Loading Dock): Exempt 3-RR (Common Space Types:Restrooms): Exempt 4-OFFICES (Common Space Types: Lounge/Breakroom) 438 0.73 320 5-STORAGE (Warehouse:Medium/Bulky/Pallet Material Storage) 1000 0.58 580 Total Allowed Watts = 34203 Area Category Exemption Qualifications Fixtures Total # Watts Activity Area Pre -Aft. Repl./Added Pre -Alt. Post -Alt. LOADING QOCL (Common Space Types7lLoadha Dock 4 10631063 0 308.000 308.000 sa.ft.) Exemption: Less than 10% fixture replacement. RR ( Common Space Types 7Restrooms 576 sq.ft.l 6 0 924.000 924.000 Exemption: Less than 10% fixture replacement. Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ of Fixture C X D) Fixture Fixtures Watt. PLAY AREA (Gymnasium/Fitness CenterPlaying Area 27753 sq ft )) LED 1: TYPE B/B-EM: GENERAL FLOOR LIGHTS: Other: 1 47 160 7520 HID 1: TYPE EX: GENERAL FLOOR LIGHTING: Metal Halide: Standard: 1 55 350 19250 LOADING DOCI ( Common Space Types4Loadina Dock 1063 sq ft.)• Exempt Linear Fluorescent copy 1: TYPE EX: EXISTING LIGHTING: 48" T8 32W: Magnetic: 2 4 77 308 RR ( Common Space Tyoes:Restrooms 576 gq ft) x mot Linear Fluorescent copy 2: TYPE EX: EXISTING LIGHTING: 48" T8 32W: Magnetic: 2 6 77 462 OFFICES ( Common Space Typesall-ounne/lareakroom438 sq IJI Linear Fluorescent: TYPE A/A-EM: GENERAL FLOOR LIGF jTS: 48" T8 32W: Magnetic: 3 5 96 480 STORAGE ( Warehouse•Medium/Bulky/Pallet Material $torage 1000 sq ft ) LED 1 copy 2: TYPE B/B-EM: GENERAL FLOOR LIGHTS: Other: 1 3 160 480 Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3_Construction Documents\3.4 Energy Page 1 of 6 Compliance\PZD18005 Altitude Sanford FL.cck Interior Lighting Compliance Statement = -° Compliance Statement. The proposed interior lighting building plans, specifications, and other calculations st systems have been designed to meet the 2017 Florida 4.0.8.1 and to comply with any applicable mandatory i DON PENN. P.E. Name - Title 10011111111111111, p .J PEEN Afl, N SF W on pillATE i;pres 'r Total Proposed Watts = 27730 this document is consistent with the ion. The proposed interior lighting ion requirements in CQMcheck Version on Checklist. 04/04/18 Date Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3 Construction Documents\3.4 Energy Page 2 of 6 Compliance\PZD18005 Altitude Sanford FL.cck COMcheck Software Version 4.0.8.1 Inspection Checklist Energy Code: 2017 Florida Building Code, Energy Conservation Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section 7D I Plan Review Complies'? Req,4p _ e C405.6 Plans, specifications, and/or Complies PR17]1 calculations provide all information Does Not with which compliance can be Not Observabledeterminedfortheelectricalsystems Not Applicableandequipmentanddocumentwhere exceptions are claimed. Provisions are made for metering individual tenant units. Feeder connectors (for feeder and branch circuits) sized in accordance with approved plans with maximum drop of 5% voltage drop total. C103.2 Plans, specifications, and/or Complies PR4]1 calculations provide all information Does Not with which compliance can be Not Observabledeterminedfortheinteriorlighting and electrical systems and equipment Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: Comments/Assumptions 1 1 High Impact (Tier 1) 2 1 Medium impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3 Construction Documents\3.4_Energy Page 3 of 6 Compliance\PZD18005 Altitude Sanford FL.cck Section I Rough -In Electrical Inspection Complies? Comments/Assumptions Re .tD I C405.2.1 Lighting controls installed to uniformly Complies EL15]1 reduce the lighting load by at least Does Not 50%. Not Observable Not Applicable C405.2.1 Occupancy sensors installed in Complies EL18]1 required spaces. Does Not Not Observable Not Applicable C405.2,1, - Independent lighting controls installed Complies C405.2.2. per approved lighting plans and all Does Not 3 EL23]2 manual controls readily accessible and visible to occupants. Not Observable Not Applicable C405.2.1 Automatic controls to shutoff all Complies 1 building lighting installed in all Does Not EL22]2 buildings. Not Observable Not Applicable C405.23 Daylight zones provided with Complies EL16]2 individual controls that control the Does Not lights independent of general area lighting. Not Observable Not Applicable C405.2.3, Primary sidelighted areas are Complies C405.2.3. equipped with required lighting Does Not 1, C405.2.3. controls. Not Observable 2 Not Applicable EL20]1 C405.2.3, Enclosed spaces with daylight area Complies C405.2.3. under skylights and rooftop monitors Does Not 1, C405.2.3. are equipped with required lighting controls. Not Observable 3 Not Applicable EL21]1 C405.2.4 Separate lighting control devices for Complies EL4]1 specific uses installed per approved Does Not lighting plans. Not Observable Not Applicable C405.2.4 Additional interior lighting power Complies EL8]1 allowed for special functions per the Does Not approved lighting plans and is automatically controlled and Not Observable separated from general lighting. Not Applicable C405.3 Exit signs do not exceed 5 watts per Complies EL6]1 face. Does Not Not Observable Not Applicable Additional Comments/Assumptions: i 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3_Construction Documents\3.4_Energy Page 4 of 6 Compliance\PZD18005 Altitude Sanford FL.cck section Final inspection; 6z Req-YD C303.3, Furnished O&M instructions for C408.25, systems and equipment to the 2 building owner or designated FI17]3 representative. Compiles?_ Complies Does Not Not Observable Not Applicable C405.4.1 Interior installed lamp and fixture Complies FI18]1 lighting power is consistent with what Does Not is shown on the approved lighting plans, demonstrating proposed watts Not Observable are less than or equal to allowed Not Applicable watts. C408.2.5. Furnished as -built drawings for Complies 1 electric power systems within 90 days Does Not FI16]3 of system acceptance. Not Observable Not Applicable C408.3 Lighting systems have been tested to Complies FI33]1 ensure proper calibration, adjustment, Does Not programming, and operation. Not Observable Not Applicable Additional Comments/Assumptions: Comments/Assumption s See the Interior Lighting fixture schedule for values. 11 1 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 31 Low Impact (Tier 3) Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3_Construction Documents\3.4_Energy Page 5 of 6 Compliance\PZD18005 Altitude Sanford FL.cck Project Title: Altitude Trampoline Park Report date: 04/03/18 Data filename: Z:\Phase Zero Design\PZD18005 - Altitude Sanford FL\3 Construction Documents\3.4_Energy Page 6 of 6 Compliance\PZD18005 Altitude Sanford FL.cck Documented Construction Value: $ Job Address: % ITE, N11ti1 Rfc L Historic District: Yes No Parcel ID: Residential Commercial Type of Work: New Addition Alteration Repair %Demo Change of Use Move Description of Work: iQ z`ztk's / 1-- Plan Review Contact Person: Phone: Fax: Name Street: City, State Zip: Title: Email: Property Owner Information Phone: Resident of property? : Contractor Information Name .t SS t EG7 'EL' 2 C ST 'yc7 , 5 Phone: 5 0 - 5 3 Z Street: 1-544XV O Fax: City, State Zip: L' d`i!t r/ u A Ic—L ` State License No.:- Name: Street: City, St, Zip: Bonding Company: Address: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. Revised: June, 2018 Permit Application FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 616 Edition (2017) Florida Building Code N(YFICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of (411rer/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Signature of Contractor/Agentent Dategg Print Contractoorr/AAgnt's Name i naturs bPl"KftiQa Date STATE OF FLORIDA C*ro* GG217377 Pxiaes 512112a22 Contractor/Agen is rersonallv Known to Me or Produced ID L1 Type of IE BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: FIRE: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: June, 2018 Permit Application d'2 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: $ $503,953.00 Job Address: 1810 Rinehart Rd., Sanford, FL 32771 Historic District: Yes No 0 Parcel ID: _ 29-19-30-512-0000-0010 Residential Commercial RI Type of Work: New Addition Alteration 0 Repair DemoEl Change of Use Move U Description of Work: Interior alterations for fit out of an indoor trampoline park. Scope of work includes new restrooms/ plumbing fixtures, interior walls and doors, electrical, mechanical, and structural which includes a raised metal -, hid and nl=npri platform Plan Review Contact Person: Robyn Kiernan Title:. Project Architect _ Phone: ( 781) 452-7121 Fax: (800) 866-0031 _ Email: rkiernan@phasezerodesicin.com Property Owner Information Name 1810 Rinehart, LLC (Attn: Tomer Graziani) Phone: (818) 331-4888 Street: 6701 Franrivers Ave City, State Zip: _ West Hills, CA 91307 Resident of property? : , No _ Contractor Information Name Philco Construction (Attn: Matt Tomlinson) Phone: (407) 647-7445 Street: 114 N. Park Ave Fax: None City, State Zip: Sanford FL 32771 State License No.:. CBC1260967 Architect/ Engineer Information Name: James Kimball Street: 35 Pond Park Rd, Bay 16 City, St, Zip: Hingham, MA 02043 Bonding Company: Address: Phone: ( 781) 452-7121 Fax: ( 800) 866-0031 E- mail: jkimball@phasezerodesign.com Mortgage Lender: - 44 Business Capital Address: 1787 Send Parkway West, Bldg 16 Suite 200 Blue Bell, PA 19422 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5th Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application 4: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and z ing. 04/04/2018 4161 11 Signature of Owner/Agent Date ignature of Contractor/Agent Date James R. Kimball (Agent) Print Owner/Agent's Name ha ID (A-LDYLrA.0,V) OLI 105 IDO) Signature of Notary -State of Florida Date t Stephanie S. Cushman NOTARY PUBLIC STATE OF FLORIDA w - ? Comm# GG158657 E /9 Expires 11/7/2021 Owner/Agent is Personally Known to Me or Produced ID Type of ID prlix t.,1 a2r+t9r.I Li 5' / Print Contractor/Agent's Name oy Icis bol8 Signature of Notary -State of Florida Date SPRY Stephanie S. Cushman NOTARY PUBLIC STATE OF FLORIDA i Gomm# GG158657 CE 19-I%' Ex Tres 11 /712021 Contractor/ Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTEWATER: L111 BUILDING: Revised: June 30, 2015 Permit Application A JUN 2 6 2018 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: Job Address: Historic District: Yes NoEl ParcelID: Residentialo Commercial El TypeofWork: Ne Add7ionE3 AlterationEl RepairEl Demo El Changeofilsen Move 1"' ( A[] Description ofWork: 4 1 Plan Review Contact Person-, -Title: Phone: Fax: Email. Property Owner Informa tion Name Phone: Street: Resident of property? City, State Zip: Contractor Information Name4 Phone: Street: Fax: City, State Zip: State License No.: Architect/Engineer Information Name: Phone: Street: City, St, Zip: Bonding Company: Address: Fax: E- mail. Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICEFORIMPROVEMENTSTOYOURPROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED ANDPOSTEDONTHEJOBSITEBEFORETHEFIRSTINSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULTWITHYOURLENDERORANATTORNEYBEFORERECORDINGYOURNOTICEOFCOMMENCEMENT. Applicationis hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced priortotheissuanceofapermitandthatallworkwillbeperformedtomeetstandardsofalllawsregulatingconstructioninthisjurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105. 3 Shall be inscribed with the date of application and the code in effect as of that date: 5lb Edition (2014) Florida Building Code Rcvised: June 30, 2()l 5 Permit Application MQUM; In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may befoundinthepublicrecordsofthiscounty, and there may be additional Permits required from other governmental entities such as watermanagementdistricts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713, The City of Sanford requires payment of'a plan review fee at the time of permit submittal. A copy of the executed contract is requiredinordertocalculateaplanreviewchargeandwillbeconsideredtheestimatedconstructionvalueofthejobatthetimeofsubmittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, inaccordancewithlocalordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work willbedoneincompliancewithallapplicablelawsregulatingconstructionandzoning. Signature ofowncrJk9-e--1-- —D-W Print Owner!Agent's Name Signature—--- Fla,, Owner/Agent is Personally Known to Me or Produced ID r Type of ID 19nature Of ConlractoCAgent ' Date CtF -:L r6f_. PrinfContractor/Agent's Name Signature of Notary -State of Florida Date Jky puoet' PAMELA S TERNUS COmmisslon # GG 11 o622 Expires August 7, 2021 r, F%. WNW rhu 6499t NOWY SWVreS Contractor/Agellt,i Personally Known to Me or Produced ID t-ype of ID LLOW IS FOR OFFICE USE ONLY Permits Required: Building[] Construction Type:_ Electrical El Mechanical [] Occupancy Use: — Plumbing[] Gas[] Roof 0 Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories-. New Construction, Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: YesEJ No [] # of HeadsFire Alarm Permit: Yes [] No[] APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING__ COMMENTS: Revised: Junc 30, 2015 Pcmiit Application ifi• FIRE DEPARTMENT U Building & Fire Prevention Division PERMIT APPLICATION r, Application No: r 5,1 D 2— Documented Construction Value: $ 9,50Q Job Address: 16 to44T i CV v6ffZ ,F,L V-771 Historic District: Yesl:]NoF] Parcel ID: 29- - 39- 61.E - 0dO ` O IO Residential Commercia M Type ofWork: NewElAdditiono Alteration Repair Demo Change of Use Move Description of Work: 5,6 =5Lz z-'re- "e/ = , & r'4F1_J= -50-t t/f,le 7' ,5,p/f LE, S r an tev16w ontactPerson: ay2ileA.1 kffl?'CLC, Z51t %40- %GTitle, ,, Phone: liP Fax: Email:a¢L' ( Property Owner Information 5P*1fs Name 191 d flVF 66Le -( 1-4 Phone: Street: ()7011 Le: QIt R4 4t !.5 4tft- Residentofproperty? City, State Zip: yt/E t A1114-51 6W 9! 7 Contractor Information Name LG /1,' 5•'/rf,-s;. %G'' Street: City, State Zip: . r(f`e , dT l44 3 771 Name: Street: City, St, Zip: Bonding Company: Address: Phone: 25- , c o Fax: _ 329 _ -' % State License No.: ' 7ziM(' 66- 9 G Architect/Engineer Information Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6ih Edition (2017) Florida Building Code C>pry j \ - CC- Permit Application In Revised: January 1, 2018 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the pen -nit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your pen -nit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructionADOnin Signature of Owner/Agent Date Signature of Contractor/Agent Date Print Owncr/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Print Co a or/Agent's Name y ¢/ atgrnsture m rrvotary-atare or rionaa mare Donavan 0. M601 N NOTARY PUBLIC STATE OF FLORIDA CMvn# GG208980 Contractor gent Ex47s IVCWW Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical[] Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: FIRE- 7 /P 1 9 BUILDING: Revised: January t, 2018 Permit Application Jimmy Patrords Casia Sinco CHIEF FINANCIAL OFFICER BUREAU GRIEF Julius Halas Keith McCarthy DIVISION DIRECTOR SAFETY PROGRAM MANAGER wt FLORIDA DEFkRTMENT OF FINANCIAL SERVICES DIVISION OF STATE FIRE MARSHAL 200 Fast Gatncs Street - Tallahassee, Florida 32399-0342 Tel. 850-413-1644 fax, 850410-2467 CERTIFICATE OF COMPETENCY O-4XCIAL COPY THIS CliRTIFIESTHAT: Charles W Montgomery 9030 Bellhurst Way, Suite 130 West Palm Beach FL 33411 BUSINESS ORGANIZATION: Delta Fire Sprinklers Inc. Contractor I includes the execution of contracts requiring the ability, experience, knowledge, science, and skill to intelligently layout, fabricate, install, inspect, alter, repair, or service all types of Fire Protection Systems, excluding Pre -Engineered Systems, issue Date I ypc - Class: County: License/Permit Expiration Date: Chief Financial Officer 0 7 /(? 1 /',' () 18 10 Seminole 749740-0001-1990 06/30/2020 6/29/2018 SCPA Parcel View: 29-19-30-512-0000-0010 r. J kill Property Record Card Parcel: 29-19-30-512-0000-0010 Property Address: 1810 RINEHART RD SANFORD, FL Parcel Information Parcel 29-19-30-512-0000-0010 Owner(s) 1810 RINEHART LLC Property Address 1810 RINEHART RD SANFORD, FL Mailing 6701 FRANRIVERS AVE WEST HILLS, CA 91307- Subdivision Name SEMINOLE COMMONS Tax District SII-SANFORD DORUse Code 11 -STORES GENERAL -ONE STORY Exemptions Legal Description LOT 1 SEMINOLE COMMONS PB 80 PGS 8 & 9 Taxes Taxing Authority County General Fund Schools City Sanford SJWM( Saint Johns Water Management) County Bonds Sales I Seminole County GCS Value Summary Valuation Method Number of Buildings Depreciated Bldg Value Depreciated EXFT Value Land Value (Market) Land Value Ag Just/ Market Value Portability Adj Save Our Homes Adj Amendment I Adj P& G Adj Assessed Value 2018 Working Values Cost/ Market 1 1, 556,234 151, 951 1, 200,025 2017 Certified Values Cost/ Market 1 1, 464,292 154, 757 1, 165,073 2, 908,210 $2,784,122 0 0 0 0 QnA 91171 0 0 0 2, 784,122 Tax Amount without SOH: $53,013.00 2017 Tax Bill Amount $53,013.00 Tax Estimator Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments Assessment Value Exempt Values Taxable Value 2, 908,210 0 2,908,210 2, 908,210 0 2,908,210 2, 908,210 0 2,908,210 2, 908,210 0 2,908,210 2, 908,210 0 2,908,210 Description Year Built Stories Total SF Ext Wall Actual/ Effective 1 MASONRY PILASTER 2008 1 30,196 FACE BLOCK - MASONRY Amount I Qualified I-, ... . ...... . .. 1-111-1 - 1 5, 325,000 No Units Price 166439 7.21 Adj Value ' Repl Value Appendages 1, 556,234 $1,778,553 Description Area OPEN PORCH 1256. 00 FINISHED Permits Permit # Description Agency Amount CO Date Permit Date 01413 DEMO INTERIOR SANFORD 19,000 3/29/2018 Permit data does not originate from the Seminole County Property Appraiser's office. For details or questions concerning a permit please contact the building department of the tax district in which the property Is located. Extra Features 00 Description Year Built Units Value New Cost WALKS CONC COMM 1/11/2008 2,785 w 6, 914 9,218 POLE LIGHT STEEL 5 ARM 1/11/2008 3 21,570 21,570 POLE LIGHT STEEL 4 ARM 111/2008 6 33,798 33,798 POLE LIGHT STEEL 2 ARM 1/11/2008 3 7,560 7,560 POLE LIGHT STEEL 1 ARM 1/11/2008 5 4,820 4,820 LOAD WELL 1/112008 2,278 2,563 3,417 COMMERCIAL ASPHALT DR 3 IN 1/11/2008 81,668 74,726 99,635 http:// parceldetail.scpafl.org/ParcelDetaillnfo.aspx?PID=29193051200000010 1/2 6/29/2018 SGPA Parcel View: 29-19-30-512-0000-0010 http://parceidetaii.scpafl.org/ParcelDetail lnfo.aspx?PID=29193051200000010 2/2 DATE: , / I OX 3 BUSINESS/PROJECT NAME: ADDRESS: CONTACT NAME: CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION FIRE PLAN REVIEW SERVICE FEES PHONE: 407.688.5052 FAX: 407.688.5051 PERMIT NUMBER: 7101 -Z-, - PHONE: PLAN REVIEW INFORMATION CONSTRUCTION []C/O [] FIRE ALARM FIRE SPRINKLER []HOOD [ ]PAINT BOOTH []TANK DOES 20% REDUCTION IN FIRE IMPACT FEES APPLY: YES TOTAL FEES: 0wwft%IL mr. 0LitI DELTA F-11AL SM44KI. lniM, INC. 111Tech Drive Sanfordjlorida32771 Phone (407) 328 3000 Fax (407) 328 3001 www.Defta-Firekonj TO: CITY OF SANFORD 300 N. PARK AVE. SANFORD, FL 32771 PROJECT: ALTITUDE TRAMPOLIONE 1810 RINEHART RD. SANFORD, FL 32771 FROM: DELTA FIRE SPRINKLERS INC. 111 TECH DRIVE SANFORD, FL. 32771 Commercial * Residential e Industrial Design e Fabrication * Installation * Maintenance 9 Inspection Page 1 of 4 MICROFAST" QUICK IllyA RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) NIKJW*j E The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK350 is a small, thermo- sensitive, glass -bulb spray sprinkler available in several different finishes, tempera- ture ratings, and K-Factors to meet design requirements. The special Polyester, and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are listed/approved as as indicated in the Approval Charts, 2. LISTINGS AND APPROVALS G w cULus Listed: Category VNIV FM Approved: Class Series 2000 vds) VdS Approved: Certificates G414017, G414018, G4980020, and G4060054 LKH LPCB Approved: Certificate 096e/03 CE Certified: Standard EN 12259-1, EC -certificate of constancy of performance 0832-CPR-SO021 and EC -certificate of conformity 0786-CPD-40278 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) 0 MED Certified: Standard EN 12259-1, EC -certificate of conformity 0832-MED-1003 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP, 3/4" NPT, 20 mm BSP Nominal K-Factor: 8.0 U.S. (115.2 metric**) Glass -bulb fluid temperature rated to -65 °F (-55 *C) Overall Length: 2-5/16" (59 mm) cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Fqr Polyester Coated Sprinklers: Belleville Spring -Exposed For ENT Coated jgrinklers: Belleville Spring -Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK350 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-W, Black Polyester = M-B, and ENT = JN Temperature Suffix (°F/*C): 135*/57* = A, 155°/68° = B, 175*/79* = D, 200*/93* = E, and 286'/141 * = G For example, sprinkler VK350 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 18259AB Form No. F_033014 18,06.21 Rev 18.2 Replaces Form F_033014 Rev 18.1 Added MED approval) Page 2 of 4 MICROOASTO QUICK RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475MB (available since 2017) Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A (available since 1971) B. Twelve -head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfasr Quick Response Upright Sprinkler VK350 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 11- AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES wmm j { 7 Ordinary 135 -F (57 °C) 100 -F (38 -C) Orange Ordinary 155 -F (68 -C) 100 -F (38 -C) Red Intermediate 175 °F (79 -C) 150 -F (65 -C) Yellow Intermediate 200 °F (93 -C) 150 -F (65 °C) Green High 286 -F (141 -C) 225 -F (107 -C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion -Resistant Coatings': White Polyester, Black Polyester and ENT. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51 c-e. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Figure 1: Sprinkler Wrench Form No. F_033014 18.06.21 Rev 18.2 Page 3 of 4 MICROFAST® QUICKNIKJRESPONSEUPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 2 a u p Base Part Thread Size Nominal Overall Length Listings and Approvals' SIN K-Factor (Refer also to Design Criteria.) Number' NPT BSP U.S, metric' Inches mm cULus° VdS LPCB E-1a '° f 18257 VK350 3/4" 8.0 115.2 2-5/16 59 Al, B2 Al Al B11 B1 18278 VK350 20 mm 8.0 115.2 2-5/16 59 At, B2 Al Al B17 B1 182599 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al. 62 Al Big 20382 VK350 3/4" 8.0 115.2 2-5/16 59 C3 20237 VK350 -- 20 mm 0 1 115.2 2-5/16 59 C3 066656 VK350 3/4" 8.0 115.2 2-5/16 59 At, B2 Al Al 61' 61 14817 VK350 , 20 mm 8.0 115.2 2-5/16 59 At, B2 Al Al 1717 B1 067646° VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 At, B2 Al Alg Approved Temperature Ratings Approved Finishes A - 135 °F (57 °C), 155 -F (68 °C), 175 °F (79 -C), 200 -F (93 °C), and 286 °F (141°C) 1 - Brass, Chrome, White Polyester's, and Black Polyester's B - 155 °F (68 °C), 175 °F (79 °C), 200 -F (93 °C), and 286 °F (141°C) 2 - ENT' C - 155 °F (68 -C) 3 - Chrome Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. s Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC -certificate of constancy of performance 0832-CPR-SO021 and EC -certificate of conformity 0786-CPD-40278. 9 The 1/2" NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. MED Certified, Standard EN 12259-1, EC -certificate 0832-MED-1003. cULus Listina i • The Microfasr Quick Response Upright Sprinkler VK350 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT- Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033014 18,06.21 Rev 18.2 Page 4 of 4 MICROFAST11 QUICK TECHNICAL DATANIKIW*j RESPONSE UPRIGHT SPRINKLER VK350 (K8,0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Base Part Thread Size Nominal K-Factor Overall Length FM Approvals' SIN Number' NPT I BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) 18257 VK350 3/4" 8.0 115.2 2-5/16 59 At, B2 18278 VK350 20 mm 0 115.2 2-5/16 59 Al, B2 182591 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al, B2 06665E VK350 3/4" 0 115.2 2-5/16 59 Al, B2 14817 VK350 20 mm 8.0 115.2 2-5/16 59 At, B2 0676461 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al, B2 Approved Finishes Approved Temperature Ratings C), -F -F °F 1 - Brass, Chrome, White Polyester', and Black A - 135 °F (57 °C), 155 °F (68 175 (79 °C), 200 (93 °C), and 286 (141°C) C), Polyester' B - 155 -F (68 °C), 175 °F (79 °C), 200 °F (93 and 286 °F (141°C) 2-ENT Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. The 1/2" NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. 6 FM approved as corrosion proofing for corrosive environments. FM Approval Reguirements: The Microfasr Quick Response Upright Sprinkler VK350 is FM Approved as a quick response Non -Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033014 18.06.21 Rev 18.2 Replaces Form F_033014 Rev 18.1 Added MED approval) Page 1 of 6 cR MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49068 Telephone: 269-945-9601 Technical Services: 877-384-6464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast" Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatingscan be used in decorative applicationswhere colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cuu. os cULus Listed: Category VNIV FM Approved: Class Series 2000 wwjs] VdS Approved: Certificates G414009 and G414010 W6 LPCB Approved CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-SO021 ca-) CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass - bulb fluid temperature rated to -65 *F (-55 *C) Overall Length: 2-1/4" (58 mm) cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring -Exposed For ENT Coated Sprinklers: Belleville Spring -Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 *C) =A, 155 °F (68 °C) = B, 175 *F (79 *C) = D, 200 °F (93 *C) = E, 286 °F (141 *C) = G For example, sprinkler VK302 with a Brass finish and a 155 *F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: ( Also refer to the current Viking price list.) Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 Replaced wrench 10896W/B with 21475M/B) Page 2 of 6 0) MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) N411QM4 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017). B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) A'/2' ratchet is required (not available from Viking). Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A (available since 1971) B. Twelve -head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap -----......., 0> - 9) Figure 1: Standard Sprinkler Wrench 21475M/B Form No, F_033314 17.10.05 Rev 17.2 Page 3 of 6 MICROFAST" QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS R FINISHES t Will Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion -Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verity through the end -user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B' for recessed pendent sprinklers A 1/2" ratchet is required not available from Viking) 4 Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 17,10.05 Rev 17.2 Page 4 of 6 MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Base Sprinkler Thread Size Nominal Overall Listings and Approvals' Part SIN K-Factor Length (Refer also to Design Criteria.) StyleNumber' NPT BSP U.S. metric' Inches mm cULus4 VdS LPCB C LfCC 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X At AiZ, 81Y D1Z, C1Y 19780 VK302 Pendent 1/2" 5.6 80.6 2-1/4 58 D3 21354 VK302 Pendent 15 mm 5.6 80.6 2-1/4 58 D3 06662E VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1X, BtY Al I A1X, BtY D1X, CtY8 D1X, C1Y9 Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 -F (57 -C), 155 °F (68 °C), 175 °F 1 - Brass, Chrome, White X - Standard surface -mounted escutcheon or the 79 -C), 200 -F (93 °C), 286 °F (141 °C) Polyester e, Black Polyes- Viking Micromati& Model E-1 Recessed Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175-F terse Y - Standard surface -mounted escutcheon or the 79 °C), and 200 °F (93 °C) 2 - Ell Viking Microfasr Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 °F (68 °C), 175 °F (79 °C), and 3 - Chrome matic'8' Model E-1, E-2, or E-3 Recessed Escutcheon 200 `F (93 "C) Z - Standard surface -mounted escutcheon or the D - 155 °F (68 °C), 175 °F (79 °C), 200 °F Viking Microfasl4r Model F-1 Adjustable Escutcheon 93 °C), 286 °F (141 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in Ii divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. s cULus Listed as corrosion -resistant. fi Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC -certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC -certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. e MED Certified, Standard EN 12259-1, EC -certificates of conformity 0832-MED-1003 and 0832-MED-1008. c4 Lus Listing Requirements: The Viking Microfast" Quick Response Pendent Sprinkler VK302 is cLILus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 5 of 6 MICROFASTO QUICKE11:S1 PRINKLER VK302 (K5.6) The Viking Corporation, %1uNIndustrial Park Drive, Hastings /N|*g058 Tm| epbuno;2V8'V45'85V1 Technical Services: ur7-3W4-54G4 Fax: 268-8184680 Emai\:umhevca@vikinguurp.00m Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN Style NP Tl BSP U.S. metric' Inches mm (Refer also to Design Criteria.) Approved Escutcheons Approved Temperature Ratings X Standard surface -mounted escutcheon or the B- 135 -F (57 -C), 155 F (68 -C), 175 -F (79 'C), and 1 - Brass, Chrome, White Polyester4, Y Standard surface -mounted escutcheon or the 200 - F (93 -C) and Black Polyester4 Viking Microfast"' Model F-1 Adjustable Escutcheon, I Viking Microfasr Model F-1 Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion resistant, FM Approval Reouirements: The Viking Microfast Quick Response Pendent SprinNo,VK302 is FM Approved asquick response Non -storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable RN Loss Prevention Data Sheets (including Data Sheet2'O). FM Global Loss Prevention Data Sheets contain guidelines m|odnq to. but not limited to: minimum water supply requiements, hydraulic design, ceiling slope and obstructiono, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from ouLus and/orwrPA criteria. IMPORTANT: Always refer to Bulletin Form No. P_U91G99 ' Care and Handling of Sprinklers. Also refer to page F080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of WFP#. FM '31obo|' LPCB' APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_U38314 1710.05 Rov172 Page 6 of 6 CRC MICROFAST11 QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-6464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-6/16" (59 mm) minimum 15 mm) 2-1/2" (64 mm) maximum NPT t ( 54 mm) 2-1/4" 57 mm) 1-3/4" 2" (38 mm) 45 mm) ( 51 mm) Min. Max. Installed with a standard Installed with a Microfast Note: At maximum, adapter 1/8" surface -mounted Model F-1 Adjustable is exposed 1/2" (13 mm) escutcheon Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon 2-1 /8" 54 mm) k 1-3/4" 45 mm) Max. 4' m"111111-12 z x 2-1/8" w (54 mm) 1-118" 2' ' 29 mm) M n. (51 mm) a Max. ti Ceiling Opening Size: 2-5/16" (69 mm) minimum 2-1/2" (64 mm) maximum 1-1/8" 29 mm) Min. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread -on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 Replaced wrench 10896W/B with 21475M/8) 5 Series SFNWnbraidedFlexible Hose Assemblies USTED Series SFBBraided Flexible Hose Assemblies <FM> '&US LWED bZnQsoonnoot the branch line to the sprinkler using aflexible stainless steel hose and reducer. The flexible stainless steel hose and fittings are intended for direct connection to the sprinkler and are particularly suited for use in suspended and hard ceiling applications, Each drop assembly comes with one stainless steel flexible hose, one branch line connection nipple, one sprinkler reducing nipple and bracket system. SYFI"'U Pm-ane* mbled.ready koinstall, unb,aidedand braided flexible main|*an steel hose lengths: 28"(700mm).40"(1000mm). 48^(1208mm). 58^(1500mm).71"(1800mn) 1/7^and W4^ outlet fittings for connecting sprinkler Pm'uuuemtded.ready h» install mounting bracket available in24"and 4O" long Mounting bracket allows the sprinkler tob*located anywhere within the ceiling with reference marks in the center for ease ofinstallation without the need for measuring. O[tiunal factory installed sprinkler head. C L D A Maximum Working Pressure: 2O0 psi ( 13?5kPu Maximum Ambient Temperature: 300`F ( 149'C) Connection \oBranch Line: 1-inch NPT Minimum Bend Radius ofFlexible Stainless Steel Hose: 3inches (76.2mm)per ULListing 8inches (203. 2mnn) per RNApproval The flexible stainless atmo) hose should not bobent within 21/2inches (84nnm)of the connection nut atboth ends. UL Maximum K'FaotorofSprinkler tobo connected to Sprinkler Reducing Nipple: V2inch outlets: 8.0 Y4inch outlets: 11.2 RNMaximum K- Factor of Sprinkler toboconnected to Sprinkler Reducing Nipple: 1/2 inch outlets: 5. 0 3/4inch outlets: 8.0 Listings and Approvals: Unbmided models are ULLiaLod Braided models are FK8Approved and ULListed 0 1 SpnnkFLEX vrr,rraMs TO is pruc.uc.k will be; We from defects rn mate+ols mid ,vorkmran,Jh'p under nort <al .orid bons of use and setme Q a perrud of one year hair rlw of seals Ow oldie_ ation undlr,r his rrracrtY is limited to rep . nng of leula<cin1r any product, fh< t is rear:ved to us with tr m por;abon charges prep:ric within cane, year afrar the {talc 0 original sale wd tt zt our e* and'iution .'rows lo our s,t€.,faction to have been . efectlr"e in rrsatr €ials or workrrrar.,ship under n.>r.rral condifions o! use and seFuif. cr, ,1„hr de-c!"jon <ss-F') vY'rr,thrr to rep<ai= cy to ; Qa, e a r tamduc.t shall be mn,-,dc ,;, rase iricl amy repalF <.h z!I ! c rlade al our i a Jliky, F. Er El _,tan in the to!("'l i ng, the'. arr ',p, ,'ifically excluded from the corn r m of to waiwa y: a) the sprinkler ,- read of any SpwkQEX prudmt but Sp mMVEX hereby a asym to the original l r m, rrz m rat any so& prtadLCt the r dirt to sKowe tine iwnrr:,nt; f my, hstwd by ;he mianufactwer of inch spnnklt head: h) rat fe. ,. t r ;ullEng flan; ordinary ytear and tr:,w of any SprwkREX Product: e') pmduds tf ` d hwe rtmn ralit?rc d in my rr rr vier by he Loys nr by anyone oher ton SprinkkL_EX; d} I}mc! ch lhat inive Wal su jecK ,f Wrii_>r, e, of darn a e, by .iccident of cat ualty; ri}rl Ir+ A - ct #, ham ?aped c r used r a anr" cont"y W ou .po ns ` catio4nSt14.lChom l -1 i_ orrecommendaticim0prc, ducts that have been rrr, tal6d cir aged >n a manna Wat 4 ntat r comomwo with ,all applicable, reclrai omeNs cf :.ry e'ade. Iaw, regulation or rule of any fe,dleral, .Mate or laical du e rrrrne~rtal or industry ar thorny; arrd g) proWs That have not bee %inspected and maintained in :)c.coi-dance 'v ith o,;r spc crfications, ;nst ct . zrrs rl,..,()rT'i'(,It)( 1cttjt)nS, n lading, W hout l hl,Fition, our uscoi-nmefiLl<.`ins as 5 follcvvcatl Te msfmct-C7n xid maiMmarve Ga lords Qhshe x by the Nafior,-,-d F ire; Protection s.,ti(.aat?nn (NF F'A); rwnd r;) I>rulds that have beer) otf .ctecj t>;r hvli<mI;dologically lnfl ien ed Como -Jon (Ml( )j I l —,-,ri << nt; is no,' ass i 1r blo and .Taal€ t, flf only the r y r al Maur haser of a ,ctjnOF f X pro Era ;t. 11 an povislon, fleieul or anypcxton of any V sun AmIl be held rn.Ad, To remands of Ids Liarted WaQ shall not be aRected the ety and all orov, i"ns Q this Limited W rvmV %hrtll na ain'vatid and in full ince and e.flect to th(,, f;alle .t extent perrnilted by la'vv, N IIS `A! (PAN T Y IS IN LIEU OF: ALL IMPLIED `rVARRANI IES, INCi l)(JING. 131.)'1' N01 LIMITED '1*1,,,), b`y'ARRAf' FIES Of:- MERCHANTAEIL_ITY AND WAI- [RANT IE.S OF FITNESS FORA A PARTICUi_AF PURPOSE, NC)-, WITHST.ANDING ANY 1-'f<'C.?VISION FO 11 IL CON RARY P 9ENi_IN OR ANY Al-411CR1'0 1: I_AW 10 (t iE= C'ON f RARY. IN 1-1 f- VI -JAI i SHALL SPRINKF LEX BE LIABLE F= C)F' IHCIDENTAt_ OR CONSEGUENTIAL. DAMAGES UNDER ANY CIRC1. MSTANCE-S Wl VVIFS )r VER, AlI THE R PJASING FROM ANY BREACH C)f'= 'l kilS L.IMIl'E:D G%fA.RRANT`i OR 0IHERWISE ARISING FROM OFF IN CONNECTION VVITI I THE USE OR CW RAAI lON OR OR ANY DEFECT IN, ANY SPRINKFL.E X PRODUCT, i,.)R 0'1'H E RWI` Ek I"la= from my boach . `'warrar #7 'r dh Ru,pe d to injury to :an,, aill be earn hti the purc.fi;rsear of SpmikF LEX. SpnnkFLEX vrr,rraMs TO is pruc. uc.k will be; We from defects rn mate+ols mid ,vorkmran,Jh'p under nort <al .orid bons of use and setme Q a perrud of one year hair rlw of seals Ow oldie_ ation undlr,r his rrracrtY is limited to rep . nng of leula<cin1r any product, fh< t is rear:ved to us with tr m por;abon charges prep:ric within cane, year afrar the {talc 0 original sale wd tt zt our e*and'iution .'rows lo our s, t€.,faction to have been . efectlr"e in rrsatr €ials or workrrrar.,ship under n.>r.rral condifions o! use and seFuif.cr, ,1„hr de-c!"jon < ss-F') vY'rr,thrr to rep<ai= cy to ; Qa, e a r tamduc.t shall be mn,-,dc ,;, rase iricl amy repalF <.h z!I ! c rlade al our i a Jliky, F. Er El _,tan in the to!("'l i ng, the'. arr ',p, ,'ifically excluded from the corn r m of to waiwa y: a) the sprinkler ,-read of any SpwkQEX prudmt but Sp mMVEX hereby a asym to the original l r m,rrz m rat any so& prtadLCt the r dirt to sKowe tine iwnrr:,nt; f my, hstwd by ;he mianufactwer of inch spnnklt head: h) rat fe. ,.t r ;ullEng flan; ordinary ytear and tr:,w of any SprwkREX Product: e') pmduds tf `d hwe rtmn ralit?rc d in my rr rr vier by he Loys nr by anyone oher ton SprinkkL_EX; d} I}mc! ch lhat inive Wal su jecK , f Wrii_>r, e, of darn a e, by .iccident of cat ualty; ri}rl Ir+A - ct #, ham ?aped c r used r a anr" cont"y W ou .po ns ` catio4nSt14.lChom l -1 i_ or recommendaticim 0 prc,ducts that havebeenrrr, tal6d cir aged > n a manna Wat 4 ntat r comomwo with ,all applicable, reclrai omeNs cf :.ry e'ade. Iaw, regulation or rule of any fe,dleral, .Mate or laical du e rrrrne~rtal or industry ar thorny; arrd g) proWs That have not bee %inspected and maintained in :) c.coi-dance 'v ith o,;r spc crfications, ;nst ct . zrrs rl,..,()rT'i'(,It)(1cttjt)nS, n lading, W hout l hl,Fition, our uscoi-nmefiLl<.`ins as 5 follcvvcatl Te msfmct-C7n xid maiMmarve Ga lords Qhshe x by the Nafior,-,-d F ire; Protection s.,ti(.aat?nn (NF F'A); rwnd r;) I>rulds that have beer) otf .ctecj t>;r hvli<mI;dologically lnfl ien ed Como -Jon (Ml( )j I l —,-,ri << nt; is no,' ass i 1r blo and .Taal€ t, flf only the r y r al Maur haser of a ,ctjnOF f X pro Era ;t. 11 an povislon, fleieul or anypcxton of any V sun AmIl be held rn. Ad, To remands of Ids Liarted WaQ shall not be aRected the ety and all orov, i"ns Q this Limited W rvmV %hrtll na ain'vatid and in full ince and e.flect to th(,, f;alle .t extent perrnilted by la'vv, N IIS `A! (PAN T Y IS IN LIEU OF: ALL IMPLIED `rVARRANI IES, INCi l)(JING. 131.)'1' N01 LIMITED '1*1,,,), b`y'ARRAf' FIES Of:- MERCHANTAEIL_ITY AND WAI- [RANT IE.S OF FITNESS FORA A PARTICUi_AF PURPOSE, NC)-, WITHST.ANDING ANY 1-'f<'C.?VISION FO 11 IL CON RARY P 9ENi_ IN OR ANY Al-411CR1'0 1: I_AW 10 (t iE= C'ON f RARY. IN 1-1 f- VI -JAI i SHALL SPRINKF LEX BE LIABLE F=C)F' IHCIDENTAt_ OR CONSEGUENTIAL. DAMAGES UNDER ANY CIRC1. MSTANCE-S Wl VVIFS )r VER, AlI THE R PJASING FROM ANY BREACH C)f'= 'l kilS L.IMIl'E:D G%fA.RRANT`i OR 0IHERWISE ARISING FROM OFF IN CONNECTION VVITI I THE USE OR CW RAAI lON OR OR ANY DEFECT IN, ANY SPRINKFL.E X PRODUCT, i,.)R 0'1'H E RWI` Ek I"la= from my boach . `'warrar #7 'r dh Ru,pe d to injury to :an,, aill be earn hti the purc.fi;rsear of SpmikF LEX. 1: L UKA110 L 1',' H 0 S, '1-' N'Ef N 8 HAk' "' E C&I LISTED NO. DESCRIPTION NO. DESCRIPTION I Flexible Hose 7/8" Nominal Diameter 5 Nipple 2 Ring 6 Reducer 1/2" or 3/4" 3 Washer 7 Plastic Cap 4 Slip Nut S I M G& LISTED j T APPROWD NO. DESCRIPTION NO. DESCRIPTION 1 Flexible Hose 7/8" Nominal Diameter 5 Nipple 2 Ring 6 Reducer 1/2" or 3/4" 3 Washer 7 Braid 4 Slip Nut F 8 Plastic Cap A T 15, NO. DESCRIPTION NO. DESCRIPTION 1 24" or 48" Support Bar 4 Hex Screw 2 Center Bracket Assembly 5 Wing Bolt 3 Clamp Corrugated Flexible Hose: SS304 Support Bar: 690 Galvanized Steel SEAL: EPOM Clamp and Center Bracket Assembly: G90 Galvanized Steel SLIP NUT AND NIPPLE: 1inc-Plated Carbon Steel Hex Screw and Wing Bolts: line -Plated Carbon Steel Slip Nut and Nipple: linc-Plated Carbon Steel Optional Tamper -Resistant Screw: Zinc -Plated Carbon Steel BRAID AND BRAID RING: SS304 11 FRICTION LOSS DATA JINURAMED OM MODEL INLET & OUTLET SIZE NPT INCH LENGTH INCH (mm) NUMBER OF 90 DEGREE BENDS UL LISTED — UNBRAIDED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 401 INCH DIAMETER PIPE (C--120), FT SFN28H 1 x 1/2 28" (700mm) 2 22 SFN28T 1 x W4 28" (700mm) 2 28 SFN40H 1 x 1/2 40" (1000mm) 3 39 SFN40T 1 x 314 40" (1000mm) 3 54 SFN48H 1 x 1/2 48" (1200mm) 3 56 SFN48T 1 x 3/4 48" (1200mm) 3 63 SFN59H 1 x 1/2 59" (1500mm) 3 59 SFN59T 1 x 3/4 59" (1500mm) 3 74 SFN71H 1 x 1/2 71" (I800mm) 3 67 ffSFN71T 1 x 3Y4 71" (1800mm) 3 74 Series SFN models are unbraided/Series SFB models are braided Unbraided hoses are UL Listed Braided hoses are FM Approved and UL Listed MODEL INLET & OUTLET SIZE NPT INCH LENGTH INCH mm) UL NUMBER OF 90 DEGREE BENDS UL—BRAIDED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 401 INCH DIAMETER PIPE C-120) FT FM NUMBER OF 90 DEGREE BENDS FM —BRAIDED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 401 INCH DIAMETER PIPE (C=120), FT SFB28H 1 x 1/2 28" (700mm) 2 22 1 46.4 SFB28T 1 x W4 28" (700mm) 2 28 1 39.1 SFB40H 1 x 1/2 40" (1000mm) 3 39 1 53.9 SFB40T 1 x 314 40" (1000mm) 3 54 1 45.3 SFB48H 1 x 1/2 48" (1200mm) 3 56 2 73.4 SFB48T 1 x 3/4 48" (1200mm) 3 63 2 64.3 SFB59H 1 x 1/2 59" (1500mm) 3 59 3 89.9 SFB59T i x 3/4 59" (1500mm) 3 74 3 86.5 SFB71H 1 x 1/2 71" (1800mm) 3 67 4 112.8 SFB71T 1 x 3/4 71" (I800mm) 3 74 4 104.9 a j' i} } 3 1 k MODEL INLET & OUTLET SIZE NPT INCH LENGTH INCH (mm) FM NUMBER OF 90 DEGREE BENDS FM —BRAIDED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 401 INCH DIAMETER PIPE (C--120), FT SFB28H — E 1 x 1/2 28" (700mm) 1 48.4 SFB28T — E 1 x 3/4 28" (700mm) 1 41.1 SFB40H — E 1 x 1/2 40"(1000mm) 1 55.9 SFB40T — E 1 x 3/4 40" (1000mm) 1 47.3 SFB48H — E 1 x 1/2 48" (1200mm) 2 75.4 SFB48T — E 1 x 3/4 48" (1200mm) 2 66.3 SFB59H — E 1 x 1/2 59" (1500mm) 3 91.9 SFB59T — E 1 x 3/4 59" (1500mm) 3 88.5 SFB71 H— E 1 x 1/2 71" (1800mm) 4 114.8 SFB71 T — E 1 x 3/4 71 " (1800mm) 1 4 1 106.9 Bull Moose Tube's", "Eddy Pipe" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c@us LISTED M APPROVED n4 AM 4)AM4 NFPA 4.,: 4>- l y. ,' . ., ;r- ,.:,a ! u ;7;, F.i F .P,T wr.- a.... s._ /1 :. T, _. ,.,.,. ,. ,...,, u.. ,.,-, ,,,: ti t x "I > ' s,,.. - s '+. Ni All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM A135 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddye, Eddy Flow-, Eddylite-, and Eddythread 40 offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Ili MIC preventative coating. Bull Moose Tubes sprinkler pipe is FBCT11 compatible. PROOLI Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 401: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow': Cost effective replacement for Schedule 10. Ultra Eddy: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. Eddy Guard 110: Bull Moose Tubee, is producing product that can resist bacteriological growth even after multiple rinse -outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube' "Eddy Guard 11`I" and feel comfortable knowing that you are getting Eddy PipeO product you trust with the bacteria resistance you need. Eddy Guard Ile is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull "moose Tube' reserves the right to change product specifications without notice and without in{- ^ obligation. ull Moose Tube's" Schedule 10 and Schedule 40 are FM e . w. P.,Js ...... xP m .Irv.. Approved and UL Listed (for U.S, NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE and Canada), even though these SIZE (IN) IN) IN) ORR** WEIGHT/FT WEIGHT SIZE products do not require separate-, approvals and listings. Bull 1 1.315 1.097 15.27 1.41 Ibs/ft 1.820 91 Moose Tubes made the decision 1-1/4 1.660 1.442 9.91 1.81 Ibs/ft 2.518 61 to have them approved and listed. 1-1/2 1.900 1.682 7.76 2.09 Ibs/ft 3.053 61 Our Schedule 10 and Schedule 40 2 2.375 2,157 6.27 2.64 Ibs/ft 4.223 37 have a pressure rating of 300 PSI 2-1/2 2.875 2.635 4.92 3.53 Ibs/ft 5.893 30 and have been through the same 3 3.500 3,260 3.54 4.34 Ibs/ft 7.957 19 rigorous testing as our other fine 4 4.500 4.260 2.50 5.62 Ibs/ft 11.796 19 pipe products. Schedule 10 can be supplied roll grooved or plain end. C Bull Moose Tube'sll Schedule 10 and Schedule 40 pipes are hot NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE dipped galvanized to meet ASTM SIZE (IN) IN) IN) CRR** WEIGHTIFT WEIGHT SIZE A123 standards. All products are stencilled t0 meet FM & ULsto 1 1,315 1.049 1.00 1.68 Ibs/ft 2.055 70 s. specifications. 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1,900 1.610 1.00 2.72lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66lbs/ft 5.114 30 2-1/2* 2.875 2.468 1.00 5.80lbs/ft 7.875 30 3* 3.500 3,068 1.00 7.58lbs/ft 10.783 19 4* 4.500 4.026 1.00 10.80lbs/ft 16.316 19 Only available in Casa Grande, AZ Corrosion Resistance Ratio per latest UL Directory Listing c t,L us LISTED FM APPROVED AM4 NFPA For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@builmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH ur.moosErue cowwnMr 63017 ull Moose Tube's" Eddythread 40`1 A N ; Of S `, F B Li I—L, .rt 0 . ,` 7 1J, . "E,", L ti._. R> ,, A1_, 1ED is a lightweight replacement for Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion Has a pressure rating of 300 psi. Resistance Ratio of 1. Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM A135 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD ll" MIC preventative coating. D F .... f .,,... 4" .,.., ... f . ,-n .. . , ,,....,PI .... NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR- LB./FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-114 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1,00 2.547 3.468 44 2 2.375 2,123 1.00 3.308 4.842 30 c@us LISTED 9 APPROVED X NM WFPA x Corrosion Resistance Ratio per latest UL Directory Listing IPE For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.builmoosetube.com Or From Canada Call. (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas, TX Masury OH 63017 Bull Moose Tube's Eddylitel' is QQ a lightwall threadable pipe manufactured in NPS 1" through 2". Eddylite"i is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylitee is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. UL AISTED 9> APPROVED n4 OAMA NFPA Standard outside diameter, unlike some other lightwall threadable pipe products. lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM A135 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight dose to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10! i.' , . F.a... i7mdx. E ,, . ,. .m , NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 1-114 1.660 1.482 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 0.16 4.31 2.617 4.230 37 Corrosion Resistance Ratio per latest UL Directory Listing O ,.,., " r N For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH 63017 FM Approved and Fully Listed Sprinkler Pipe SCHEDULE 10 SPECIFICATIONS Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL C-UL and FM Listed. NIPS NOM OD NOM ID WALL WEIGHT UL PIECES in. mm In. mm In. mm lbs,/ft. k9/m CRR* Lift Approvals and Specifications Both products meet or exceed 11/4 1660 422 1A42 36,6 109 2,77 131 2.69 73 61 the following standards: 11/. 1,900 483 1.682 421 '109 2.77 2.09 3,11 5.8 61 ASTM A135, Type E, Grade A (Schedule 10) 2 2 315 603 2157 548 109 277 2,64 393 4 7 37 ASTM A795, Type E, Grade A (Schedule 40) 2% 2,875 73o 2.635 66.9 .120 3.05 3.53 5.26 35 30 NFPA 13 3 3.500 68,9 3,260 82,8 120 305 4,34 6.46 26 19 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected 4 4.500 1143 4,260 108,2 120 3,05 5,62 8,37 1,6 19 to the toughest possible testing protocols to S 5.563 141,3 5,29S 1345 134 3.40 T78 1158 15 13 ensure the highest quality and long-lasting performance. 6 6.625 1683 6,357 1615 134 3,40 9,30 13,85 to 10 a 8,625 2191 8249 2095 '188 4,78 16,96 25.26 21 7 Finishes and Coatings All Wheatland black steel fire sprinkler pipe Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category WZY, up to 6" receives a mill coating to The CRR Is a ratio value used to measure the ability of a pipe to withstand corrosion. proprietary Threaded Schedule 40 steel pipe Is used as the benchmark (value of 1.0). ensure a clean, corrosion -resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be S)ICHEDULE 40 SPECIFICATIONS easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL black, or with hot -dip galvanizing, to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES FM/UL requirements for dry systems that meet In. mm in. mm In. mm Ibs,/ft. k9/m CRR* Lift the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is 1 1.315 33.4 1,049 26,6 133 3,38 1,68 2,50 1,00 70 also UL Listed. I 1A 1,660 422 1,380 351 140 3,56 2,27 3,39 1,00 51 Product Marking 11/1 1900 48,3 1610 40.9 145 3.68 2,72 405 100 44 Each length of Wheatland fire sprinkler pipe is continuously stenciled to show 662291315435067523237560 ..,...,., 5 1 00 3045 10the manufacturer, type of pipe, grade, size Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category WZY. and length. Barcoding is acceptable as a The CRR Is a ratio value used to measure the ability of a pipe to withstand corrosion. supplementary identification method. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 1.0). @ C PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: F] BLACK F1 HOT -DIP GALVANIZED VfteatlandTube I711 V'S 111^W Of 1:1F, 1(f, 011AN 140u, I f"U_s F 1'1111 V ' 9 Quality by the Foot" Schedule 10 Sprinkler Pipe Youngstown Tube manufactures Schedule 10 pipe in sizes 1 ''/4" thru 6" using only high quality domestic steel coils. This ensures a uniform superior product for roll grooving, welding or plain end uses. Youngstown Tube's schedule 10 pipe is produced under ASTM A 135/A795 Type E, Grade A, NFI standards. Every piece is Eddy -Current tested and confonns to internal SPC testing and recording. Youngstown Tube Schedule 10 steel sprinkler pipe is coated with a waterbased black enamel coating, YTC Guard antimicrobial coating and a continuous color coded white stencil, and stored indoors ready for immediate shipment. Approvals: UL Listed, CUL Listed, FM Approved Youngstown Tube schedule 10 pipe meets the rigorous testing and certification processes of Underwriters Laboratory and Factory Mutual for steel sprinkler pipe with working pressures of300 psi or less. It also meets the requirements of NFPA 13 and can be used in wet, dry, deluge and preaction systems. Schedule 10 x Pieces Weight' UL Pipe Pipe Pipe ; Nominal' Weight Standard Feet per thitreaded Size D _ ID Wall per Foot ° Length per E3undle per Bundle: Bundle; CRR Schedule 10 pipe can not be threaded or cut -grooved. Youngstown Tube Company 401 Andrews Avenue Youngstown, Ohio 44505 1-866-The-Tube www.youngstowntube.com Project:'' Contractor: Submitted By: Date Submitted:, Y)MIDgAQWn Quality by the Foot" Schedule 40 Sprinkler Pipe Youngstown Tube manufactures Schedule 40 pipe in sizes I " thru 2" using only high quality domestic steel coils. This ensures a uniform superior product for threading, roll grooving, welding or plain end uses. Youngstown Tube's schedule 40 pipe is produced under ASTM A 135/A795 Type E, Grade A, NH standards. Every piece is Eddy -Current tested and conforms to internal SPC. testing and recording. Youngstown Tube Schedule 40 steel sprinkler pipe is coated with a waterbased black enarnel coating, YTC Guard antimicrobial coating and a continuous color coded red stencil, and stored indoors ready for immediate shipment. Approvals: UL Listed, CUL Listed, FM Approved Youngstown 'rube schedule 40 pipe meets the rigorous testing and certification processes of Underwriters Laboratory and Factory Mutual for steel sprinkler pipe with working pressures of300 psi or less. It also meets the requirements of NFPA 13 and can be used in wet, dry, deluge and preaction systems. Schedule 40 Youngstown Tube Company 401 Andrews Avenue Youngstown, Ohio 44505 1-866=rhe-Tube www.youngstowntube.com Project: Submitted By: [date Submitted:'' Contractor: 1 of 2 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION VGS" Model V-Z05 Standard Rigid Couplings are avaialble in sizes 1-1/4" through 8". VGSO Model V-Z07 Standard Rigid Couplings are avaialble in sizes 1-1/4" through 10" with Gap Seal gaskets available for sizes up to 8" under Model V-Z05F. Model V-Z07 is not available with Gap Seal gaskets. Fitting solutions are avail- able in a number of styles and configurations to support a variety of applications. VGSO Standard Rigid couplings are manufactured at IS09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to conform to ASTM F1476. c ul, us Guide No. VIZM Class 1920 3. TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are avail - The most recent VLSI Technical Data can be acessed at http://www.vikinggroupinc.com, Scan the code below to visit our Mobile website: O able (conforming to ASTM A153); when or- dering, add a "G" suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM D2000, AWWA C606. NSF 61 and IAPMO. Nuts: Zinc plated, Carbon Steel conforming to ASTM A563 Grade B Track Bolts: 1OB21 Baron Steel yy o V-Z05 and V-Z05F 1.25 1.66 300 649 0 - 0,05 2,58 4 1 85 2 318 x 2-1/8 1.5 32) 42.2) 21) 2,8) 0 - 1.2) 66) 102) 47) 07) 1 5 1.9 300 850 0 - 0.05 283 4,33 1,85 2 3/$ x 2-1l8 1.7 40) 48.3) 21) 3.66) 0- 1.2) 72) 110) 47) 0.8) 2 2.375 300 1330 0 - 0,07 3,35 4,62 1 89 2 3/8 x 2-3/4 1.9 50) 60.3) 21) 571) 0- 17) 85) 118) 48) 0.9) 25 2 875 300 1950 0- 0,07 3,82 5,24 1.89 2 3/8 x 2-3/4 21 65} 73) 21) 8.37) 0- 1.7) 97) 133) 48) 0.9) 3 3.5 300 2885 0 - 0,07 4,49 5,91 1,93 2 3l8 x 2-3/4 2.7 80) 88.9) 21) 12.41) 0- 1.7) 114) 150) 49) 1,2) 4 4.5 300 4771 0 - 0.16 5,75 7.48 2.17 2 1/2 x 3 4.3 100) 114.3) 21) 24.77) 0 k 4.1) 146) 190) 55) 2) 5 5.563 300 7290 0 - 0,16 6.87 9,11 215 2 112 x 3 5.8 125) 141.3) 21) 32,45) 0-4.1) 175) 232) 55) 2.6) 6 6.625 300 10340 0 - 0,16 7.87 10.24 2,17 2 5/8 x 5-5/1G 7 150) 168.3) 21) 46.02) 0 ^ 4.1) 200) 260) 55) 3 2) 8 8,625 300 17525 0 - 0.19 1028 12.89 2,52 2 5/8 x 5-5/16 13.3 200) 219, 1) 21) 78) 0 - 4.8) 261) 328) 65) 6) V207h 10 10, 75 300 27190 0 - 0.13 1299 15.59 2,5 2 7! 8 x 6-1/2 23.5 254 273 21 123 0 - 3.2 330 396 64 10.7 Not available with gap seal Form No. F 020614 16,03.04 Rev 16.1 Replaces form No. F_020614 Rev 15.1 Reformatting and corrections) 2 of 2 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 4. INSTALLATION Refer to the following VGSI Grooved Coupling Installation Guide (Form No. F_031114), Pipe End Preparation Guide (Form No. F — 031214), and Rubber Gasket Installation Guide (Form No. F — 031014) for detailed instructions regarding installation. Be sure that all pipes and fittings used with this coupling are standard sizes and not metric. Note: All other gasketed prducts (i.e. reducing coupling, mech tee, etc.) have never been pre -lubricated. These products have always been, and are today, marked with a single green stripe. Refer to the latest edition of the VGSO Technical Data Sheets. For additional information contact Viking Technical Services. Schedule 40, Cut Goove - Schedule 40, Roll Groove - Schedule 30, Cut Goove - Schedule 30, Roll Groove - Allied Tube & Conduit, "XU -Allied Tube & Conduit, "BLT" - Allied Tube & Conduit, "Dyna-Thread" - Wheatland Tube, "Mega -Thread" - Wheatland Tube, "GU - Wheatland Tube. "MLT" - Schedule 10, Roll Groove - Allied Tube & Conduit, "Dyna-Flow" - Bullmoose Tube, "EDDY - Flow" - Bullmoose Tube, "EDDYlite" - Northwest Tube, "EZ-Flow" - Wheatland Tube, "Mega -Flow" Schedule 40, Cut Goove - Schedule 40, Roll Groove - Schedule 30, Cut Roll Groove Form No. F020614 16.03.04 Rev 16.1 Roll Groove - Schedule 10, Replaces form No. F — 020614 Rev 15.1 Reformatting and corrections) 0 E: ROOVLD COUPLING M: G DEL V-7705 STANDARDNGSFLEXIBLECOUPLING The Viking Corporation, 21UNIndustrial Park Drive, Hastings K8|48058 Ta| mphone:2GS-845-9G01 Technical Services: O77-384'54G4 Fan:28S-818-1GDO Emmikheohsvos@viWn8corp.comm DESCRIPTION VGSI Model V7705Standard Flexible Couplings are available insizes 1^through 12^ Fitting solutions are available in a number of styles and ounfiOumhonn to support a varietyf applications.m3S*StunderdF|exib| Couplings manufac- tured at IS09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to conform VoA8TM F1478 2. LISTINGS AND APPROVALS mEuNeNo.VIZM Class | aan1820 3. TECHNICALDATA Specifications: Maximum working pressure: ompsi (2/bar) Ductile iron conforming wxSTmAum Gmuesn-4u'1e Coating rust inhibiting paint Orange nALuoo, Hot dipped Zinc galvanized versions are availa- ble (conforming /uAormxloo); when ome,' ino.aoxo~o^sumvmmemvumvumooc Rubber compound EpomGrade sconforming wAnrmozuno.mwvwAc000.NSF n1 and mpmo. Nuts: Zinc plated, Carbon Steel conforming m AaTmAnanGrade o Track Boltsi 1OB21 Boron Steel The latest voa° Technical Data can be acessedm xup,x°"ww. vim^nn,v" pinu.cum. Scan to visit eur Mobile website: S 1-1. ..ffl Form No. F_02121* 16.03. 04Rev 161 Replaces form No. F_021214 Rev 151 Reformatting and corrections) 2of2 llllllllll G ROOV ED COUPLING TECHNICAL DATANGS MODEL V-7705 STANDARD FLEXIBLE COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 4. INSTALLATION Be sure that all pipes and fittings used with this coupling are standard sizes and not metric. Refer to the following VGS® Technical Data Sheets for detailed installation instructions: Grooved Coupling Installation Guide (Form No. F_031114) Pipe End Preparation Guide (Form No. F_031214) Rubber Gasket Installation Guide (Form No. F_031014) Note: All other gasketed prducts (i.e. reducing coupling, mech tee, etc.) have never been pre -lubricated. These products have always been, and are today, marked with a single green stripe. Refer to the latest edition of the VGSO Technical Data Sheets. For additional information contact Viking Technical Services. llil"uwnow Schedule 40, Cut Goove - Schedule 40, Roll Groove - Schedule 30, Cut Goove - Schedule 30,Roll Groove - Allied Tube & Conduit, "XL" -Allied Tube & Conduit, "BLT" -Allied Tube & Conduit, "Dyna-Thread" - Wheatland Tube, "Mega -Thread" - Schedule 10, Roll Groove -Allied Tube & Conduit, "Dyna-Flow" - Bullmoose Tube, "EDDY -Flow" - Bullmoose Tube, "EDDYlite" - Wheatland Tube, "Mega -Flow" Form No. F_021214 16.03.04 Rev 16.1 Replaces form No. F_021214 Rev 15.1 Reformatting and corrections) 1 of 1 II IGROOVED COUPLING TECHNICAL DATA MODEL V-7706 REDUCING COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION VGSO Model V-7706 Reducing Couplings are available in sizes 2" through 8" with various size outlets as shown in Table 1. Fitting solutions are available in a number of styles and configurations to support a variety of applications. VGSO Reducing Couplings are manufactured at IS09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and desiqned to conform toASTM F1476. CAUTION Do not use the Model V-7706 Coupling with an end cap: the end cap may be sucked into the pipe when draining the system. 2. LISTINGS AND APPROVALS c llt us Guide No. VIZM Fro Class 1920 3. TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Coating rust inhibiting paint - Orange RAL 2001 The latest VGSO Technical Data can be accessed at http://www.vikinggroupinc.com. Scan to visit our Mobile website: 0. i http://vikinggrou p. mobi/p/46374 Hot dipped Zinc galvanized versions are avail- able (conforming to ASTM A153); when or- dering, add a "G° suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM D2000. Nuts: Zinc plated, Carbon Steel conforming to ASTM A563 Grade B Track Bolts: 10621 Boron Steel 4. INSTALLATION Refer to the following VGS" Grooved Coupling Installation Guide (Form No. F 031114), Pipe End Preparation Guide (Form No. F_031214), and Rubber Gasket Installation Guide (Form No. F_031014) for detailed instructions regarding installation. Be sure that all pipes and fittings used with this coupling are standard sizes and not metric. Form No. F_021314 16.03.04 Rev 16.1 Replaces form No. F 021314 Rev 15.1 Reformatting and corrections) GROOVED FITTINGS NGS k 111111 MI :MO D ELBOWS The Viking Corporation, 210 NIndustrial Park Drive, Hastings K8|4SO58 Te|* phone:2G8-945'9S01 Technical Services: O77-3O4-54G4 Fau:269'D1O-1G88 Enmmi|:baohsvoa@vikin0oorp.uom 1. DESCRIPTION VGS11 Model V-711O.V-7111.V7112.and V-7113Elbows are available insizes 1 ^ through 12^ Fitting solutions available in a numberof figurations to support a variety of applications. VGS11 grooved -end fittings are manufactured at IS09001 certified facilities an are designed to conform to ASTM and other standards where applicable, These products are manufactured and designed to meet ASTM F1 548 and and ANSI/AWWA C606 requirements for use with grooved mechanical couplings conforming to ASTM F1 476. 2. LISTINGS AND APPROVALS xVwl GuidoNo, V|ZA Class 1820 D. TECHNICAL DATA Specifications: Maximum working pressure: 3U0psi (21 Ductile iron conforming toASUmA53O Grade5545-12 Coating rust inhibiting paint-OrongaRAL 2001 Hot dipped Zi | i edvemiunsae available (conforming toASTMA155); when ordering, add a^G^suffix mthe Model number. The latest voa° Technical Data can be acessed at mtp,mm*^w" imnmemuni^u.nom. Scan ouvisit our Mobile wvun/m: 0 11..1 wall, ft____ httv:mxxmoYmu». mouxowaxr^ TABLE 1: VGS GROOVED ELBOW SIZING CHART Nominal 90' Elbow 46' Elbow 22.6* Elbow 11.26' Elbow Form No. F101515 16. 06,02 Rev 15,1 (VGS" branding, expanded technical data) 2of2 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com D Model V-7110DR 90' Drain Elbow TABLE 2: VGS Model 1 R ' GROOVED DRAIN Dimensions i WeightNominalSizePipeO.D. Lbs (Kg) C-E D E I In (mm) in (mm) in (mm) In l(mm) in (mm) 2 2.375 3.25 2.25 1.57 2.14 50) 60) 83) 57) 40) 0.97) 2.5 2.875 3.75 2.75 1.53 3.1 65) 73) 95) 70) 39) 1.4) 3 3.5 4.25 2.75 1.93 4.6 80) 89) 108) 70) 49) 2.1) 4 4.5 5 2.75 2.48 7.3 100) 114) 127) 70) 63) 3.3) 6 6.625 6.55 2.75 3.54 13.8 150) 168) 166) 70) 90) 6.3) 8 8.625 7.8 3.27 4.49 27.1 200) 219) 197) 83) 114) 12.3) Form No. F_101515 16.06.02 Rev 15.1 (VGS"', branding, expanded technical data) GROOVED FITTINGS a MODEL V-7120 TEE14GSOR: MODEL V-7135 CROSS The Viking Corporation, 21UNIndustrial Park Drive, Hastings K8|49O5g Telephone: 269'845-9501 Technical Services: O77`]84'8484 Fax: 269-818-1680 Email: tanhovca@vikinQcorp.ummm 1. DESCRIPTION VGGwMode VJ120 andV-7135 fittings are available in sizes 1-1/4^ through 12^ Fitting solutions are available inanumber o(styles and configurations to support a variety of applications, VGSI grooved -end fittings are manufactured at IS0901 certi- fied facilities an are designed to conform toAOTM and other standards where ap- p|ioab|*. These products are manufactured and designed \nmeet ASTxxF1548and and ANS\ 6AwVVAC60O requirements for use with grooved mechanical cnup|ingo conforming onA8TM F1476. 2. LISTINGS AND APPROVALS v\usGuNallo. V|ZA C|oso182O 3. TECHNICAL DATA Specifications: Maximum working peoouna: 300paK21 bar) Ductile iron conforming toA5TM A588 GnydoO5'45' 12 Coating rust inhibiting paint ' Orange RAL 2001 Hot dipped Zinc galvanized versionsavail- able (conforming VoAOTM A153),when ordering, add a^G'suffix tothe Model numbe, The latest voaO Technical Data can be acessed at up:xwww.wmnoyn, vpinu.cvm, Scan *, visit our Mobile wwuaioo: Model w,20 To Model `-7, 35 Cross TABLE 1: VGS GROOVED FITTING SIZING CHART V-7120 Too V-7135 Cross Nominal Size Pipe O.D. C-E C-E Form No. F_ 1U2715 18,V3.O4Rev 161 Replaces Form No. F _1O2715Rev 15] Ronnu8ingandunrreciona) 1 of 1 Q NJGS • GROOVED FITTINGS MODEL V-7160 END CAP The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com im DESCRIPTION VGS® Model V-7160 End Caps are available in sizes 1-1/4" through 12". Fitting solutions are available in a number of styles and configurations to support a variety of applications. VGS® grooved -end fittings are manufactured at IS0901 certified facilities an are designed to conform to ASTM and other standards where appli- cable. These products are manufactured and designed to meet ASTM F1548 and and ANSI/AWWA C606 requirements for use with grooved mechanical couplings conforming to ASTM F1476. 2. LISTINGS AND APPROVALS c 0L us Guide No. VIZA Class 1920 3. TECHNICAL DATA The latest VGS' Technical Data can be acessed at http://Www.vikinggroupinc.com. Scan to visit our Mobile website: p Model V-7160 End Cap Specifications: I http://vikinggroup.mobi/p/46374 Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are available (conforming to ASTM A153); when ordering, add a "G" suffix to the Model number. 1: VGS ModelTABLE1ENDCAPSIZINGCHART V 7160 End Cap Nominal Size Pipe O.D. L.bs (Kgs) In (mm) In (mm) In ( E 1.25 1.66 1 0.4 32) 42) 25) 0.2) 1.5 1.9 1 0.4 40) 48) 25) 0.2) 2 2.375 1 0.7 50) 60) 25) 0.3) 2.5 2.875 1 0.9 65) 73) 25) 0.4) 3 3.5 1 1.5 80) 89) 25) 0.7) 4 4.5 1 2.4 100) 114) 25) 1.1) TABLE I • 1 END CAP SIZING CHART V7160 End Cap Nominal Size Pipes O.D. E L. bs (Kgs) In (mm) in (mm) In ( mm) 5 5.563 1 3.7 125) 141) 25) 1.7) 6 6.625 1 6.6 150) 168) 25) 3) 8 8.625 1.18 12.1 200) 219) 30) 5.5) 10 10.75 1.25 15.4 250) 273) 32) 7) 12 12.75 1.25 22 300) 323.9) 32) 10) Form No. F_103015 16.07.28 Rev 15.1 (VGS* branding, expanded technical data) 1 of 1 GROOVED FITTINGS MODEL V-7150 CONCENTRICN4GSINREDUCER The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION VGSI Model V-7150 Concentric Reducer fittings are available in sizes 1-1/4" through 12" with various outlet sizes as shown in Table 1. Fitting solutions are available in a number of styles and configurations to support a variety of applications. VGSO grooved -end fittings are manufactured at IS09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to meet ASTM F1548 and and ANSI/AVVWA C606 re- quirements for use with grooved mechanical couplings conforming to ASTM F1476. 2. LISTINGS AND APPROVALS c uL us Guide No. VIZA FM Class 1920 3. TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 G 6 4 12 The latest VGS Technical Data can be acessed at http://www.vikinggroupinc.com. Scan to visit our Mobile website: Model V-7150 Concentric Reducer rade 5- 5- Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are available (conforming to ASTM A153); when ordering, add a "G" suffix to the Model number. 1: VGS ModelTABLECONC. V 7160 Concentric Nominal Size Pipe O.D. Reducer EIn (mm) In (mm) Lbs (Kgs) In (mm) 1.25x1 1,66x1315 25 05 32 x 25) 42 x 33) 64) 0,23) 15x1 19x1315 2.5 05 40 x 25) 48 x 33) 64) 0.23) 15x125 19x166 2.5 07 40 x 32) 48 x 42) 64) 0.32) 2x1.25 2.375x166 25 0.9 50 x 32) 60 x 42) 64) 0.41) 2x1.5 2375x1.9 25 1.0 50 x 40) 60 x 48) 64) 0,45) 25x15 2875x1.9 2.5 13 65 x 40) 73 x 48) 64) 0.59) 25x2 2.875x2375 25 12 65 x 50) 73 x 60) 64) 0.54) 3x1.25 35x166 25 15 80 x 32) 89 x 42) 64) 0,68) 3x15 3.5x19 25 16 80 x 40) 89 x 48) 64) 0.73) 3 x 2 3.5x2.375 2.5 1.5 80 x 50) 89 x 60) 64) 0.68) 3 x 2 5 35x2875 2.5 1.6 80 x 65) 89 x 73) 64) 0.73) 4x15 45x19 3 24 100 x 40) 114 x 48) 76) 1.08) 4 x 2 45x2.375 3 2.4 100 x 50) 114 x 60) 76) 1.08) 4 x 2.5 4.5 x 2,875 3 2.6 100 x 65) 114 x 73) 76) 1.18) 4 x 3 4.5x3.5 3 2.6 100 x 80) 014 x 89) 76) 1.18) Modeli CONC. REDUCER SIZING CHART V 7150 Concentric Nominal Size Pipe O.D. Reducer EIn (mm) in (mm) Lbs (Kgs) In (mm) 5 x 4 5563x4.5 3.5 40 125 x 100) 141 x 114) 89) 1.81) 6 x 2 6,625 x 2.375 4 5.9 150 x 50) 168 x 60) 102) 2.68) 6 x 2.5 6.625 x 2 875 4 5 4 150 x 65) 168 x 73) 102) 2.45) 150 x 80) 68 x 89) 102) 2.86) 6 x 4 6625x4.5 4 5.4 150 x 100) 168 x 114) 102) 2.45) 6 x 5 6625x5563 4 62 150 x 125) 168 x 141) 102) 2.81) 8x3 8625x35 5 104 200 x 80) 219 x 89) 127) 4.72) 8 x 4 8625x45 5 137 200 x 100) 219 x 114) 127) 6.21) 8 x 5 8625x5563 5 10.8 200 x 125) 219 x 141) 127) 4.96) 8 x 6 8.625 x 6.625 5 13.1 200 x 150) 219 x 168) 127) 5.94) 10x4 10.75x4.5 6 17.9 250 x 100) 273 x 114) 152) 8.12) tOx6 1075x6625 6 243 250 x 150) 273 x 168) 152) 11.02) 10x8 1075x8.63 6 20.1 250 x 200) 273 x 219) 152) 9.12) 12x6 1275x6625 7 35.1 300 x 150) 323 x 168) 178) 15.92) 12x8 12,75x8.63 7 31.6 300 x 200) 323 x 219) 178) 14.33) 12 x 10 12.75 x 1075 7 29.1 3100 x 250) 323 x 273) 178) 13,12) Form No. F 102815 16.03.04 Rev 16.1 Replaces Form No. F_102815 Rev 15.1 Reformatting and corrections) 1 of 2 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION VGSI Model V-M22 Mechanical Tees are available in sizes 2" through 8". The Models V-M22 mechanical tees provide an easy take-out of a branch outlet with- out the need for welding. VGS® Mechanical Tees are manufactured at IS09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to meet ASTM F1548 and and ANSI/AWWA C606 requirements for use with grooved outlet conforming to ASTM F1476. 2. LISTINGS AND APPROVALS c ul us Guide No. VIZM FM Class 1920 3. TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 The latest VGSI Technical Data can be acessed at http://www.vikinggroupinc.com. Scan to visit our Mobile website: Grade 65-45-12 Coating rust inhibiting paint - Orange RAC 2001 Hot dipped Zinc galvanized versions are available (conforming to ASTM Al53); when ordering, add a "G" suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM D2000, AWWA C606, NSF 61 and IAPMO. Nuts and Bolts: Zinc plated, Carbon Steel conforming to ASTM A183 Grade 2 (UNC nuts and bolts are a silver chromate color and ISO are a gold chromate color) Form No. F_110415 16.03.04 Rev 16.1 Replaces form No. F_110415 Rev 15.1 Reformatting and corrections) 2of2 The Viking Corporation, 210 N Industrial Park Drive, Hastings M149058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Continued from previous page. 4 x 1 4.500 x 1.315 1.5 3.9 2,64 7,19 3.13 1/2 x 3 3.9 100 x 25) 114 x 33) 38) 99) 67) 183) 79) M12 x 75) 1.77) 4 x 1.25 4,500 x 1.660 2.0 3.9 2.64 7,19 4.00 112 x 3 4.3 100 x 32) 114 x 42) 51) 99) 67) 183) 102) M12 x 75) 1,95) 4 x 1.5 4.5 x 1.9 20 4.60 2,64 7.19 4.00 1/2 x 3 4A 100 x 40) 114 x 48) 51) 102) 67) 183) 102) M12 x 75) 2.0) 45-50 4 x 2 4.5 x 2.375 2.5 4.00 2.64 7.19 4.06 1/2 x 3 4.7 (61-68) 100 x 50) 114 x 60) 64) 102) 67) 183) 103) M12 x 75) 2.13) 4 x 2.5 4.5 x 2.875 2,75 4.00 2.64 7.19 4,44 1/2 x 3 5.0 100 x 65) 114 x 73) 70) 102) 67) 183) 113) M12 x 75) 227) 4 x 3 4.5x3.5 3.5 4,12 2.64 7.19 506 1/2x3 5.7 100 x 80) 114 x 90) 89) 105) 67) 183) 129) M12 x 75) 2.59) 5 x 2 5.563 x 2.375 2.5 4,59 32 8.82 4.00 5/8 x 3-1/2 6.2 Y 125 x 50) 141 x 60) 64) 117) 81) 224) 102) M16 x 90) _ 2.81) 5 x 2.5 5.563x 2.875 2,75 4,59 3.2 8.82 4 45 5/8 x 3-1/2 6.6 125 x 65) 141 x 73) 70) 117) 81) 224) 113) M16 x 90) 2,99) 5 x 3 5.563 x 3.500 3.5 4.59 3.2 82 5.28 5/8 x 3-1/2 7.1 125 x 80) 141 x 89) 89) 117) 81) 224) 134) M16 x 90) 3,22) 6 x 1.25 6.625 x 1.660 2.0 5,17 3.72 9,87 3,63 5/8 x 3-1/2 6.6 150 x 32) 168 x 42) 51) 131) 95) 251) 92) M16 x 90) 2.99) 6 x 1.5 6,625 x 1.990 2.0 5,15 3.72 9.87 3.63 5/8 x 3-1/2 6.5 85-90 150 x 40) 168 x 48) 51) 131) 95) 251) 92) M16 x 90) 2.95) (115-122) 6 x 2 6,625 x 2.375 2.5 5.13 3.72 9.87 4,19 5/8 x 3-1/2 6.9 150 x 50) _ 168 x 60) 64) 130) 95) 251) 106) M16 x 90) 3.13) 6 x 2.5 6.625 x 2,875 2,75 5,33 3,72 9.87 4,61 5/8 x 3-1/2 7A 150 x 65) 168 x 73) 70) 136) 95) 251) 117) M16 x 90) 3.36) 6 x 3 6.625 x 3.500 3.5 5.31 3,72 9.87 5.35 5/8 x 3-1/2 8.0 150 x 80) 168 x 90) 89) 135) 95) 251) 136) M16 x 90) 3.63) 6 x 4 6.625 x 4.500 4.5 5,51 3,72 9.87 6,38 5/8 x 3-1/2 9.9 150 x 100) _ 168 x 114) 114) 140) 95) 251) 162) M16 x 90) 4.49) 8 x 2.5 8.625 x 2,875 2,75 6,54 502 12,87 4,57 3/4 x 4-3/4 14A 200 x 65) 219 x 73) 70) 166) 128) 327) 116) M20 x 120) 6.53) 8 x 3 8.625 x 3.500 3.5 6.54 4.72 12.87 5,43 3/4 x 4-3/4 15A 120-170 200 x 80)_ 219 x 89) 89) 166) 120) 327) 138) M20 x 120) 6.99) (163-230) 8 x 4 8.625 x 4.500 4.5 6.54 4,72 12,87 6,44 3/4 x 4-3/4 17.3 200 ) 100} 219 x 114) _ 114) 166) 120) 327) 164 M20 x 120) 7.85} Hole diameters are suggested hole saw diameters. 1 Take-out (Center of run to end of pipe to be engaged) 4. HOLE CUTTING The hole -cut method of pipe preparation is required when using mechanical tees, mechanical crosses, and saddle -lets. The method of pipe preparation requires the cutting or drilling of a specified hole size on the centerline of the pipe. Always use the correct hole saw size as shown this data sheet and never use a torch for cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8" (16 mm) of the hole should be inspected to ensure a clean smooth surface, free of any indenta- tions or projections that could affect proper gasket sealing. The area within the "A" dimension should also be inspected and must be free for dirt, scale or any imperfection that could affect proper seating or assembly of the fitting. A Font No. F_110415 16.03.04 Rev 16.1 Replaces form No. F_110415 Rev 15.1 Reformatting and corrections) The Viking Corporation, 21ON Industrial Park Drive, Hastings K8|49O58 Te|ephone:269-945'9S01 Technical Services: OT7'D84'5464 Fam:%GS-01Q'1GO0 Emmmiitechmvns@vihinAco,p.00nm 1' DESCRIPTION VGSO Model V-M21 Mechanical Tees anaavaialble in sizes %^through 8^ The Mnde|uV-M21 mechanical tees provide uneasy take-out ofobranch outlet with- out the need for welding. VGS11 Mechanical Tbao are manufactured at |S08001 certified facilities an are designed to conform to ASTM and other standards where applicable, Threads are NPTper ANSI O1.2O1 2. LISTINGS AND APPROVALS usGuide No, VIZM Class 3. TECHNICAL DATA Maximum nOpmusure 300psi (21 bar) Ductile iron conforming to AOTMA536 Gad 22 Coating rustinhibiting paint Orange RAL2001 Hot dipped Zinc igakmnized versionse amm available (conformingwhe n oa` number. compoundEPDMGrade Econforming A8TMD2VOU.AxVVVA C80O. NSF O1and K\PMO. Nuts and Bolts: Zinc plated, Carbon Steel conforming VoASTM A183Grade 2(UNCnuts and bolts are asilver chromate color and ISO are agold chromate color) Form No, F_110315 1O. O3.O4Rev 1O1 Replaces Form No. F_ 11O815Rev 151 Reformatting and corrections) 2 of 3 HOLE CUT SYSTEM TECHNICAL DATA "L V-M21 MECHANICAL TEENGS@ (FEMALE THREADED OUTLET) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Continued from previous page. Table 1: V-M21 3 x 0.5 1,5 2.72 2,95 2,09 6,19 319 1/2 X 2-3/8 3,3 80 x 15) (38) (69) (75) (53) (157) (81). (M12 X 60) (1,50) 3 x 0.75 1.5 2.72 2.95 2,09 6,19 31 19 1/2 X 2-3/8 3.3 80 x 20) (38) 69) (75) (53) 157) 81) (M12 X 60) (1.50) 3 X 1 1.5 2,76 3,07 2,09 6,19 3,19 1/2 X 2-3/8 3.4 80 X 25) (38) 70) (78) (53) 157) 81) (M12 X 60) (1.54) 3 X 1.25 2,0 3,11 15 2.09 619 3,7 1/2 X 2-3/8 41 80 X 32) (51) 2 79) (89) (53) 157) 94) 2 X 60)___ (1.86) 3 X 1,5 0 3,11 15 2,09 619 31 1/2 X 2-3/8 4,2 80 X 40) (51) 79) (89) __(53)__ 157) 94) (M12 X 60) (1 91) 3 X 2 2.5 107 3.5 2,09 6,19 4,25 1/2 X 2-3/8 47 80 X 50) (64) 80) (89) (53) 157) 108) (M12 X 60) (2,13) 4 x 0.5 1.5 145 3,69 2,64 719 313 1/2 X 3 4,0 100 X 15) (38) 88) (94) 67) 183) 79) M12 X 75) 1,81) 45-50 4 x 0.75 1,5 145 3,69 2,64 7,19 3.133T 1/2 X 3 40 (61-68) 100 x 20) (38) 88) (94) 67) 183) 3) 9) f l 79) M12 X 75) 181) 4 X 1 1,5 3,37 3.69 2,64 7.19 3,13 1/2 X 3 41 100 X 25) (38) 86) _(94) 67)_ 183) 79) M12 X 75) 1,91) 4 X 1,25 2,0 3,23 3,63 2,64 7.19 4 1/2 X 3 45 100 X 32) (51) 82) (92) 67) 183) 102) M12 X 75) 2,04) 4 X 1,5 2.0 161 4.00 2,64 7,19 4 1/2 X 3 4,9 100 X 40) (51) 92) (102) 67) 183) 102) M12 X 75) 2,22) 4 X 2 2 5 3,57 400 2,64 7,19 4,06 1/2 X 3 5,3 100 X 50) (64) 9 1) (102) 67) 183) 10-3) M12 X 75) 2,4) 4 X 2.5 2,75 3,45 4,00 2,64 7,19 4,44 1/2 X 3 5,8 100 X 65) (70) 88) (102) 67) 183) 113) M12 X 75) 2.63) 4 X 3 3,5 3.39 4.13 2.64 7,19 5.06 1/2 X 3 6,3 100 X 80) (89) 86) (105) 67) 183) 129) M12 X 75) 286) 5 X 2 2,5 4,15 4.59 12 8,82 4.02 5/8 X 3-1/2 6,6 125 X 50) (64) 106) (117) 81) 224) 102) M16 X 90) 2,99) 5 x 2.5 2.75 4.06 4.72 3.2 8,82 4.49 518 X 3-1/2 7.4 125 x 65) (70) 103) (120) 81) 224) 114) M16 X 90) 3.36) 5 x 3 3.5 3,98 4,72 3.2 882 5.28 5/8 X 3-1/2 82 125 x 80) (89) 101) (120) 81) 224) 134) M16 X 90) 3,72) 6 X 1,25 2.0 4.73 5.13 3,72 9.87 3,63 5/8 X 3-1/2 6,9 150 X 32) (51) 120) (130) 95) 251) 92) Mle X 90) 3,13) 6 X 1.5 2,0 4,73 5.13 372 9,87 3,63 5/8 X 3-1/2 7,0 85-90 150 X 40) (51) 120) (130) 251) 92) M16 X 90) 3,18) (115-122) 6 X 2 2,5 4,69 512 372 9,87 4,19 5/8 X 3-1/2 75 150 X 50) (64) 119) (130) 95) 251) 106) M16 X 90) 3,40) 6 X 2.5 2.75 4.45 5.12 3,72 9.87 4.61 5/8 X 3-1/2 81 150 X 65) (70) 113) (130) 95) 251) 117) Mie X 90) 3,67) 6 X 3 3,5 4,37 5,12 372 9,87 5.35 5/8 X 3-1/2 87 1150 x 80) (89) 111) (130)— 95) 251) 136) M16 X 90) 3,95) 6 x 4 4,5 4.69 5.51 3,72 9.87 6.38 5/8 X 3-1/2 111 150X100) —( 114) 119) (140) 95) 251) 162) M16 X 90) 5,31) 8 x 2.0 2,75 6,10 6.54 5,02 12,87 4.57 3/4 X 4-3/4 14.4 200 x 50) (70) 155) (166) 128) 327) 1 ( 116) M20 X 120) 6,53) 120-170 8 x 2,5 2.75 5.87 6.54 5,02 12,87 4.57 3/4 X 4-3/4 15,6 (163-230) 200 x 65) (70) 149) (166) 128) 327) 1 (116) M20 X 120) 7o8) LHole diameters are suggested hole saw diameters, '*T Take-out (Center of run to end of pipe to be engaged) Form No. F110315 16.03.04 Rev 16.1 1 of 2 HOLE CUT SYSTEM 4GS MODEL V-723 SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION VGSO Model V-723 Saddle Let small mechanical tees are available in sizes 1-1/4" through 2-1/2". The Models V-723 mechanical tees provide an easy take-out of a branch outlet without the need for welding. VGS1 Mechanical Tees are manufac- tured at IS09001 certified facilities an are designed to conform to ASTM and other standards where applicable. Threads are NPT per ANSI 131.20.1. 2. LISTINGS AND APPROVALS c Ul, I Guide No. VIZM FM Class 1920 3. TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 The latest VGS® Technical Data can be acessed at http://www.vikinggroupinc.com. Scan to visit our Mobile website: Grade 65-45-12 Standard black finish Hot dipped Zinc galvanized versions are available (conforming to ASTM A153); when ordering, add a "G" suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM D2000, AWWA C606, NSF 61 and IAPMO. Form No. F 110515 16.06.02 Rev 15.1 (VGS`11 branding, expanded technical data) 2 of 2 HOLE CUT SYSTEMNMODELV-723 SADDLE LET4GS : MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-6464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Nuts and Bolts: Zinc plated, Carbon Steel conforming to ASTM A183 Grade 2 (UNC nuts and bolts are a silver chromate color and ISO are a gold chromate color) 4. HOLE CUTTING The hole -cut method of pipe preparation is required when using mechanical tees, mechanical crosses, and saddle -lets. The method of pipe preparation requires the cutting or drilling of a specified hole size on the centerline of the pipe. Always use the correct hole saw size as shown this data sheet and never use a torch for cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8" (16 mm) of the hole should be inspected to ensure a clean smooth surface, free of any indenta- A tions or projections that could affect proper gasket sealing. The area within the "A" dimension should also be inspected and must be free for dirt, scale or any imperfection that could affect proper seating or assembly of the fitting. 5. INSTALLATION NOTES: Use a wrench to hold the threaded outlet in place when installina the sprinkler Tighten the nuts evenly, U-Bolt Hole Gasket Threaded outlet Nuts Sprinkler Figure 1: V-723 Saddle -Let Installation VGSO branding, expanded technical data) Form No. F110515 16.06.02 Rev 15.1 Ductile Iron Threaded Fittings Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP Ductile iron castings conform to ASTM A536 C QL) us LISTED Fitting dimensions conform to ASME 1316,3 Bushings and plugs conform to ASME B16.14 FM > Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME 131.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings 20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 A A A Fig. 35E 3 - 90' Elbow C usQ. 9 FM APPRQVEO LISTED Size in Part Number A in Packing Weight 1bInnerMaster 112 35E 3004 1,13 100 200 0,2 3/4 35E 3006 1.31 70 140 03 1 35E 3010 1,50 40 80 0,5 1.1/4 35E 3012 1,75 25 50 0.8 1-112 35E 3014 1,94 18 36 1.1 2 35E 3020 2,25 10 20 1.8 2-1/2 35E 3024 270 4 8 3,2 Fig. 35RE3 - 90' Reducing Elbow Size in Part NumberI A in B in Pac Ina Weight lbInnerIMaster 3/4 x 112 35RE3006004 1,20 1,22 80 160 0,3 1 x 1/2 35RE3010004 1,26 1,36 70 140 0.4 1 x 3/4 35RE3010006 1,38 1,45 50 100 0A 1- 1/4 x 112 35RE3012004 1,34 1.53 35 70 0,5 1-1/4 x 3/4 35RE3012006 1,45 1,63 35 70 0,6 1-1/4 x 1 35RE3019010 1.58 1,67 30 60 0.7 1-112 x 112 35RE3014004 1,52 1.75 30 60 0.6 1- 112 x 3/4 35RE3014006 1.52 1,75 25 50 0.7 1-112 x 1 35RE3014010 1,65 1,80 20 40 0.8 1-112 x 1-1/4 35RE3014012 t82 1,88 18 36 1'0 2 x 112 35RE3020004 1.60 1,97 18 36 1.0 2 x 3/4 35RE3020006 t60 1,97 18 36 1'0 2 x 1 35RE3020010 1.73 2.02 16 32 12 2 x 1-1/4 35RE3020012 1,90 2,10 12 24 1 3 2 x 1-112 35RE3020014 202 2.16 10 20 1,5 2-1/2 x 1-1/2 35RE3024014 216 2,51 6 12 2,2 2-112 x 2 35RE3024020 2 39 2.60 6 12 25 Fig. 35F 3 - 45' Elbow Size in Part Number A in Pac ing Weight lbInnerMaster 112 35F 3004 0,88 150 300 02 3/4 35F 3006 0,98 80 160 0.3 1 35F 3010 1,13 40 80 0.5 1-1/4 35F 3012 129 25 50 0,7 1-112 35F 3014 1,44 20 40 1,0 2 35F 3020 1,69 10 20 1.6 2-112 35F 3024 1,95 4 8 2,7 Fig. 35T 3 - Tee Size in Part Number in Pac ina Weight - 1bInnerMaster 112 35T 3004 1,13 80 160 0.3 3/4 35T 3006 131 30 60 0.5 1 35T 3010 1,50 25 50 0.7 1-1/4 35T 3012 1,75 10 20 1A 1-112 35T 3014 1.94 10 20 1.5 2 35T 3020 2,25 6 12 2A 2-112 35T 3024 2.70 4 8 4.3 111 I-COOPHIR INTERNNHONAL" * TOIA, FREIF 1-800-706-0076 * FAX (323) 8904456 0 wwNv.smithcooper.com C <> @ us A Owo Fig. 35RT3 - Reducing Tee LISTED Size in Part Number A Iin B in C in Pac ino Weight lbInnerMaster 3/4 x 112 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 112 35RT3010004 1,26 1,26 136 30 60 U 1 x 112 x 1 35RT3010004010 1.50 1,36 1,50 30 60 0,6 1 x 3/4 35RT3010006 1.38 1.38 1,45 25 50 0.6 1 x 3/4 x 3/4 35RT3010006006 1.38 1,31 1,45 35 70 0,6 1 x3/4x I 35RT301OW6010 1.50 1.45 1 ZO 25 50 0,7 1-1/4 x 112 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 112 x 1-1/4 35RT3012004012 1,75 1.53 115 25 50 0.9 1-114 x 3/4 35RT3012006 1.45 1.45 1,62 15 30 0,9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1,75 1.62 1.75 20 40 to - 1-1/4 x 1 35RT3012010 1,58 1,58 1.67 15 30 1'0 1-1/4 x 1 x 112 35RT3012010004 1.34 1.26 1,53 25 50 0,7 1-1 /4 x 1 x 3/4 35RT3012010006 1 A5 1,38 1,63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1,50 1,69 20 40 0:9 1-1/4 x 1 x 1-1/4 35RT3012010012 1,75 1.69 1,75 15 30 1.0 1-1/2 x 112 35RT3014004 1,41 1 Al 1,66 16 32 1.0 1-112 x 112 x 1- 1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 112 x 1-1/2 35RT3014004014 1,94 1,66 1.94 12 24 1:2 1-112 x 3/4 35RT3014006 1,52 1,52 1,75 16 32 ti 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 ti 1-112 x 3/4 x 1-112 35R*T3014006014 1.94 1,75 1,94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-112 x 1 x 112 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1,50 1.44 1,75 16 32 0.9 1-112 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 to 1-1/2 x 1 x 1-1/4 35RT3014010012 1,82 1.67 t88 12 24 1.2 1-112 x 1 x 1-112 35RT3014010014 1.94 1,80 1 94 12 24 13 1- 1/2 x 1-1/4 35RT3014012 1.82 IV 1.88 12 24 1A 1- 112 x 1- 114 x 112 35RT3014012004 1,41 1,34 1.66 16 32 0,9 1- 1/2 x 1-1/4 x 3/4 35RT3014012006 1,52 1,45 1,75 16 32 1.0 1- 1/2 x 1-1/4 x 1 35RI3014012010 1,65 1,58 1,80 16 32 1'1 1- 1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 115 1.88 14 28 1.3 1- 112 x 1- 114 x 1 -1 /2 35RT3014012014 1,94 1 88 1,94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1 A9 1,88 10 20 1.5 2 x 314 35RT3020006 1.60 1,60 1.97 10 20 1,6 2xl 35RT3020010 1,73 113 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2,25 8 16 1.9 2 x 1-1/4 35RT3020012 1,90 1 90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2,25 2,10 2,25 8 16 2.0 2 x 1-112 35RT3020014 2M 2.02 2,16 8 16 21 2 x 1-112 x 112 35RT3020014004 1.49 1.41 1.88 10 20 1,3 2 x 1-1/2 x 3/4 35RT3020014006 1,60 t52 1.97 10 20 1.4 2 x 1-112 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-112. x 1-1/4 35RT3020014012 1,90 1.82 2,10 8 16 1.7 2 x 1-112 x 1-112 35RT3020014014 2.02 1,94 2,16 8 16 1.8 Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing I Weight lb InnerMasterl3/ 4 x 1 35BT3006010 1,45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1 Z7 1,67 1,58 20 40 U 1 x 1-112 35BT3010014 1,80 1,80 1.65 15 30 1,() 1- 1/4 x I x 1-1/2 35BT3012010014 1,88 t80 1.82 15 30 1.2 1- 1/4 x 1-112 35BT3012014 1.88 1,88 1.82 15 30 1.3 1- 1/4 x 2 35BT3012020 2A0 210 t90 10 20 1,6 1- 112 x 1-1/4 x 2 35BT3014012020 2.16 210 2.02 10 20 1.8 1- 1/2 x 2 1 3513T3014020 2,16 2A6 1 2.02 1 8 1 16 1 1,8 SNIFF11- COOPER I N'l'l,'RNNl'10,NAl,'l * '1'01,1, FR F' E 1-800-766-0076 * FAX023) 890-4450 0 wwxv.smithcooper.com 112 4 YVV II C@US < F> APPROVED Fig. 35CP3 - Straight Coupling with Ribs LISTED Size in Part Number A in Pac ing Weight lbInnerMaster 112 35CP3004 138 200 400 01 314 3.5CP3006 1,63 100 200 0.2 1 35CP3010 1.75 60 120 OA 1-1/4 35CP3012 2.00 35 70 05 1-112 35CP3014 2.19 25 50 U 2 35CP3020 2.62 15 30 1,2 2-112 35CP3024 3,00 9 18 22 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Pac ing Weight 1hInnerMaster 1 x 112 35RC3010004 1.69 80 160 03 1 x 3/4 35RC3010006 1,69 60 120 0A 1-1/4 x 3/4 35RC3012006 2.06 40 80 0,6 2 x 1 not hex). 35RC3020010 2,81 20 40 1.0 Fig. 35HR3 - Hex Bushing Size in Part Number A in Pac ina Weight 1bInnerIMaster 1 x 112 351 IB3010004 1,06 180 360 02 1 x 314 36HB3010006 1.06 180 360 0.1 1-1/4 x 1 35FIB3012010 1,19 90 180 02 1-112 x 1 35HB3014010 1.25 75 150 OA x 1-1/4 35HB3014012 1,25 75 150 03 2 x 1 35HB3020010 138 40 80 0,6 2 x 1-1/4 351-iB3020012 1,38 40 80 06 2x1-1/2 I 35f-1B3020014 1 1.38 1 40 1 80 1 0.6 Fig. 35SP3 - Square Head Plug Size in Part Number A in Pac ing Weight 1bInnerMaster 112 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 01 1 35SP3010 1,25 200 400 0'1 1-1/4 35SP3012 1.87 100 200 0.3 1-112 35SP3014 1.44 80 160 0A 2 35SP3020 1.50 45 90 0,6 Fig. 35U 3 - Union with Brass Seat Size in Part Number A in Pac ing Weight lbInnerMaster 1 35U 3010 2.19 20 40 1,0 1-1/4 35U 3012 2.50 15 30 1,2 1-112 35U 3014 2.62 10 20 1,7 2 _t 355LU 3020 3A2 6 12 2.4 113 S %I Hl I -COOP 1`1 R I N'FE, R N N HON Al,' * 'FO 1, 1, FK E' E 1-800-766-0076 * FAX (323) 890-4456 * .k wNvs mi thcooper,com A Ar Fig. 35X 3 - Crass C uI. US F M arPaoveo LISTED Size in Part Number A in Packin Weight lbInnerMaster 1 35X 3010 1.50 20 40 0.9 1-1/4 35X3012 1:75 12 24 1A 1-112 35X 3014 1.94 8 16 1.8 2 35X 3020 2,25 ; 6 12 2.8 Fig. 35RX3 - Reducing Crass Size in Part Number A in D in Packin Weight lbInnerMaster 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2 x 1 35RX3014010 1.84 t65 12 24 1A 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3 - Cap Size in PartNumber A in Packin Weight lb InnerMaster112 35C 3004 0.87 300 600 0.1 3/ 4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1- 1/4 35C 3012 1.28 70 140 0A 1- 112 35C 3014 1.33 50 100 0.5 2 , 35C 3020 1.45' 25 50 0.8 2- 112 35C 3024 1.70 18 36 1.6 Fig. 35BC3 - Beam Clamp Size in P art Number A in Packin Weight lb InnerMadq----j 3/ 8 35BC3003 0.75 100 200 0.3 1/ 2 35BC3004 0.75 `s 80 160 - 0.5 SNII, I,ll-COOPER IN' I'I"RNNFIONAI," 9 '1'01,1, FRI'll; 1-800-760-0076 • FAX (323) 890-4456 • vv"v%.smithcooper.com 114 PIPE RINGS (_111))^NVIL Fi g. 6 9 Adjustable Swivel Ring, Tapped Per NFPA Standards SizeRange:'/2" through 8" Material: Carbon steel Finish: Strap isPre-Galvanized Zinc Material. Nut isZinc Plated. Service: Recommended for suspension of non -insulated stationary pipe line. Maximum Temperature: aSO^F Approvals. Complies with Federal Specification A-A-llYlA(Type lO).m/m+H-/7/'E(Type /[), ANSI/MSS 5P-6Yand MSS SP'58(Type l0).ULListed and FkxApproved (Sizes `/."8''). Features: Threads are countersunk sothat they cannot become burred u,damaged, Knurled swivel nut provides vertical adjustment after piping isinplace. Captured swivel nut in the'/ 2" through 6" sizes. The capture is permanent in the bottom portion of the band, allowing the hanger to be opened during installation if desired, but not allowing the nut tofall completely out. Ordering: Specify size, figure number and name, Note: The acceptability of galvanized coatings at temperatures above 450~Fisatthe discretion of the end user. Metric nut available upon request. Non -captured nut also available upon request. FIG, 69: LOADS (LBS) * WEIGHT (LBS) * DIMENSIONS ( IN) Pipe Size Max Load Weight Rod Size A 0 C F G Width Note: Reflects changes mred mxm" m, from previously published data per recent revisions mwou*p-5oaon s LISTED APPROVED 1\vthmugh 8" pipe PROJECT INFORMATION APPROVAL STAMP Project: F]Approved Address: [] Approved as noted Contractor: 0 Not approved Engineer: Remarks - Submittal Date: Notes 1: Notes 2: px1.a 44018Columbiana-Waterford Road Columbiana, Ohio 44408 Phone: ( H0O)321-273G~:3O0\482-S250 Effective April 1A93 Fig. 10 FUNCTION: THREADED STUDS MATERIAL: FINISH: ORDERING: F Designed for use in pipe hanger assembly. Low carbon steel Plain rod size, length (B) and figure number. Max. Rec. Rod LoadAbs. Size 650OF 750OF 3/8 x B 730 540 112 x B 1350 1010 x B 1810 1610 3/4 x B 2710 2420 718 x B 3770 3360 Fig. 15 & 15L FUNCTION: MACHINE THREAD MATERIAL: HANGER ROD FINISH: Fig. 15 RIGHT-HAND THREADS ORDERING: Specify rod size, length (B) and figure number. Fig. 15L RIGHT- AND LEFT-HAND THREADS Max. Rec. Wt. Per InchAbs. 02 Available in stainless steel. To order, specify04 304 or 316 and add 07 suffix SS to figure 11 number. 14 Price on request. Designed for use in pipe hanger assembly. Low carbon steel Plain Rod Size Thread Length C LoadAbs. 650°F 750°F M. Per InchAbs. 3/8 x B 21/2 730 540 03 1/2 x B 2112 1350 1010 06 5/8 x B 21 1810 1610 09 3/4x B 3 2710 2420 13 1/8 x B 31/2 3770 3360 17 1 x B 4 1 4960 4420 22 Fig. 20 & 21 FUNCTION: CONTINUOUS THREADED ROD MATERIAL: 6. 20* PLAIN ORDERING: Fig. 21 ELECTRO-GALVANIZED Packaging Max. Rec. Rad Fnat Per R"nrfla LoadAbs Wt Per Available in stain- less steel. To order, specify 304 or 316 and add suffix SS to figure number. Price on request. W ' Available in stainless steel.To orde r, specify 304 or 316 and add suffix SS to figure number. Price on request. Useful in applications where stud lengths cannot be predetermined. Low carbon steel Specify rod size, length and figure number. Size 6 ft. 10 ft. 12 ft. 650OF 750OF FootAbs. 1/4-20 300 500 600 240 210 12 3/,-16 150 250 240 730 540 29 72 120 144 1350 1010 542-13 v'- 11 48 80 96 1810 1610 83 3/4-10 30 50 60 2710 2420 1.25 7/,_9 24 40 48 3770 3360 1.65 1-8 12 20 2-4 49-60 4-420 2.25 12 PHD Manufacturing, Inc. All I FUNCTION: Designed for the suspension of non -insulated stationary pipe lines. The knurled insert nut that allows a vertical adjustment after installation, is topped to NFPA reduced rod size standards. Fig. 141F has a layer of felt which separates the pipe from the hanger to reduce vibration and sound. APPROVALS: Underwriters' Laboratories Listed in the U.S. (UL), Canada (CUL), and Factory Mutual Approved for sines'," to 8". ( *rn 'oplies with Federal Specifications A-A-1 192A (Type 10), and Manufacturers' Standardization Society ANST/SP-69 and SP-58 (Type 10). ORDERING: Specify pipe size and figure number. Pipe oSize Adj. Max. Rec. Wt. Each Size A B C D E LoadAbs. (in lbs.) 112 1/a 1718 171,, 2 3/, 31/,6 300 .10 3/4 3/8 111/16 11/8 21b 3'/, 6 300 .10 1 3/8 1 1 2% 33/,6 300 .10 1 '/4 Yl 115/16 11/,11 213/,6 35/,6 300 .11 11/2 3/,3 21/e, 11/16 3'/8 371, 300 .11 2 3/8 2'/,6 11/a 35/16 43/8 300 .14 21/2 3/8 31/1, 15/, 315/,6 53/8 525 .19 3 3/8 3"/,6 11/'J 4,'/,6 66/,6 525 23 31/, 3/, 3`14 171,3 4Yj 65/8 525 .25 4 43/16 1 '/1 51/1675/i6 650 .30 5 1 4, 4V8 15/8 55/8 83/8 1000 .50 6 913/,6 51/8 21/, 61/2 1000 .58 8 1/" 6"3/,6 2'/,6 71543 121/4 1000 .90 Note: if ordering Fig, 141 Ffelt lined p 1*)e sizes of 31/2 " or cruder, order the enext forlargest , size to'allow lf6i- the thickness of thcfe t lining. FUNCTION: Designed for the suspension of non -insulated stationary pipe lines. "The knurled insert nut, allows for vertical adjustment after installation. Fig. 151 F has a layer of felt which separates the pipe from the hanger to reduce vibration and Sound. APPROVALS: Underwriters' Laboratories Listed in the U.S. (UL) and Factory Mutual Approved for all sizes. Complies with Federal Specification A-A-1 192A Type 10), and Manufacturers' Standardization Society ANSI/SP-69 and SO- 58 (Type 10). ORDERING: Specify pipe size and figure number, Pipe Rod Size Adj. Max. Rec. Wt. Each I SizeABCD E LoadAbs. (in lbs.) A 2112 23/, 1 '/4 3"/,6 600 33 3 b 31/8 11/8 4 600 .35 4- 1/ 65/6 600 j 35431637 4 8 37/8 415/,6 71/8 1000 .46 5 4`1/c, 1 3/t, 554 81/2 1000 .57 6 3L, 51/16 2 6"/,6 101/8 1250 1.06 8_ 1 4 6.1V 811/ 7/8 12 1 16 2 8 1 12 50 1.32 Note: L _ 3ll' ordering Fig. 1511'felt tined hangers rpipe sizes o1*311_,"oi nniler, order the next largest size to allowfor the thickness 11 tllllc felt lining., Fig. 141 & 141F NFPA SWIVEL RING HANGER Fig. 141 PRE -GALVANIZED Fig. 141F PRE -GALVANIZED WITH FELT LINING A C Xr D B MATERIAL: Low carbon steel Fig. 151 & 151F SWIVEL RING HANGER Fig. 151 PRE -GALVANIZED Fig. 151F PRE -GALVANIZED WITH FELT LINING A MATERIAL: Low carbon steel PHD Manufacturing, Inc. 25 FUNCTION: Designed for attaching hanger rod to the top flange of a beam or Fig. 350 bar joist, where the flange thickness does not exceed 3/4 inch. The BEAM CLAMP open U design permits rod adjustment. The universal design of the 1/8" Fig, 350 allows it to be used in an inverted position on the bottom flange of a beam as well. n B FM>-(R- APPROVALS: Underwriters' Laboratories Listed in the U.S. (UL), Canada (CUL), for all sizes. Factory Mutual Approved for rod sizes 1/g" and '/2" only. Complies with Federal Specifications A-A-1192A (Type 19) and Manufacturers' Standardization Society ANSI/SP-69 and SP-58 (Type 19). Fig. 350 sized for I/s" rod can be used in an inverted position (bottom of beam) and follows the same U.S. (UL.), Canada CUL), and Factory Mutual Approvals. Used in this manner the '/," Fig. 350 also complies with Federal Specifications A-A-1192A (Type 23) and Manufacturers`StandardizationSociety ANSI/SP-69 and SP-58 (Type 23) (Approvals are only for Fig. 350 with locknut). MATERIAL: Malleable iron with hardened steel cup point set screw A FINISH: Plain or electro-galvanized ORDERING: Specify rod size, finish and figure number. Rod Max. Size Pipe Max. Rec. Wt. Each A B C D E Size Load/lbs. in lbs.) A3/8 7/6 11/, 1 % 1 /;-, 4 400 33 1/2 1 1112 111 1/2 8 500 34 5/8 11/11, 1112 15/8 7/8 8 600 39 3/ 4 1 '/16 13/4 2 3/,, 5/8 8 800 63 71, 11/16 134 2 " /8 5/a 8 1200 60 USTED Note: See N4SSANS1/SP-69 and SP-58 specifications for proper set screw torque vallies. A Reversible design approved for bottom beam use. F- Fig. 360 FUNCTION: Designed for attachi ng hanger rod to the top flange of abeam or bar joist, where the flange thickness does not exceed I'/, inches. WIDE MOUTH The open U design permits rod adjustment. BEAM CLAMP APPROVALS: Underwriters' Laboratories Listed in the U.S (UL), Canada (CUL), and Factory Mutual Approved for rod sizes, / 8 and'/2 only. Complies with Federal Specifications A-A-1192A (Type 19) and Manufacturers' Standardization Society ANSI /SP-69 and SP-58 Type 19). (Approvals are only for Fig. 360 with locknut). A B USIM MATERIAL: Malleable iron with hardened steel cup point set screw FINISH: Plain or electro-galvanized ORDERING: Specify rod size, finish and figure number. Rod Max. Size Pipe Max. Rec. Wt. Each A BTC D E---Size in lbs.) 3/ 8 1 17/8 15/8 112 4 LoadAbs. 400 37 2 1 1718 15/,, 112 8 500 35 5/, 13/8 21/,6 21/, 3/4 5 850 74 3/ 4 1112 2 3/8 2 3/8 3/, 6 900 87 Note: See AJSS ANSIISP-69 and SP-58 specifications for proper set screw torque values. 34 PHD Manufacturing, Inc. Speedy Products, Inc. 2472 East Seventh Avenue North St. Paul, MN 55109 Values Speedy places values first, as the foundation for all business dealings promoting honesty, open straightforward communication and mutual respect. 9t 3L•L7 Recognized for original ideas and ewraordinary product development, we continue to provide time saving solutions for today's global construction needs. Missionn Dedicated to unparalleled customer service, superior quality and innovative products we create ever-increasing profitability and prosperity for our customers, partners and employees. The Speedy Team remains uncompromisingly committed to you! c.1,,r„fi2001V"..,iPage 1 STEEL— Sammys Self -Drilling • Self -tapping STEEL - 1/4" Rod (Vertical Mount) Use #I4 Nut Driver (Item #100) Item # Model Screw Description Box Qty Weightper100) Case Qty 50 DSTIi 100 1/4-20xl 100 6.25 1000 51 DST 100 I/4-14x1 100 5.25 1000 52 DST 150 1/4-140 1/2 100 5.50 1000 53 DST200 1/4-14x2 100 6.00 1000 54 DST 250 1/4-14x21/2 100 6.75 1000 55 DST300 1/4-140 100 7.25 I000 56 ITEK500 12-24xt 1/2 100 1 5.50 1000 14 Item #100-b") Sammys 1/4". 3/8" rod STEEL # 3/8" Rod (Vertical Mount) Use #14 Nut Driver (Item #too) Agxovals Item# Ma1cI Screw Descriloon FMTest Load,IK UL est lAadllx UtJFM Pi eSize Minimum Thickness Maximum Thickness Actual Pullout 13o: ut•FM-NFt'A 29 DSTR 11/2" 12-24x1 1/2 1475# 1500// 3/4-4 1/4" 1/2" 15100 / 1/4" 1 v13C F +Ftf !R"` Qi"`" ° J T k`i4`)'R-., L•/„_ 1f4:4-.. , w..,., ,3Cri$fT(fiY'.__ 4"` P' rl J^t(ir'f"f $' - I U1,NFVA 3 DSTR 516 5/ 16-18xl 1/4 1500# 4 036"-20 ga 1/4" 2200# / 20 1 4t}-. ti., .- s...,_k'r"4*-14kt, -- Re.L''Me 'Y(arar""`>.i pet'fJirraurrcc,/bwthe'AS't'IU(!' 1011#h)MrosightlteOsr3#(3t" fert#th)ore consoott len' hstPA only me' luatd 9 (,z-_......_.4 NFt'A 33 DSTI5 1/4-14xl1/2 1/4" 970#/16 1 NFPA 34 DST 20 1/4.14x2 1/4" 1 NFVA 35 DST25 1/4-14x21/2 NFFA 36 DST30 U4-14x3 1/4" I Ut•NFFA 37 DST516 5/16-ISxI 1/4 1500# 4 1&&"-3J16" 1/4" 15000/3/16" 1 Fht• NFFa 1 38 ITFK50 12-24x1 1/2 1475# 1 1 1/4" 1/2" 1 3125# / 1/4" I STEEL * 1/2" Rod (Vertical Mount) Use # 14SW Nut Driver (Item #101) Item # Model Screw Description Minimmn Thickness Maximum Thickness Actual Pullout BOX Qty Weight per 100) ease Qty 601 DST2.0 1/4-14x2 188"-3/16" 1/4" 50 6.75 500 1113 DST2.5 1/4-14x21/2 IR8"-3/16" 1/4" 50 7.25 500 422 DSTR 1.0 1/4-20xl 036"-20 pt 1A I51Oft / 20 ga 50 500.00 7 28 DSTR 5.16 5/16-18xt 1/4 036"-20 Urt 1/4" 2220# / 20 50 8.00 500 443 DST S.16 5/16-18x11/4 188"-MV 1/4" 1500+#/3/16" 50 6.75 500 0, 5 TF1f5.0 I 12-24x11/2 25"-1/4" 1/2" 3125#/1/4" 50 0.00 500 14SW Item # 101-red) Sidewinders & Sammys 1/2" rod For fastening/anchoring, in high vibratory environments, corrsalt local code authorities for accepted anchoring devices UL Listings and CAD Drawings are available at www.SammySuperScrew.com STEEL —Sidewinders Self Drilling # Self -tapping reel sn•<•r shn",r, wh rranim r. nnr SWDR sere..=. include retuiurr nut 14SW Item #101 red) Sidewinders & Sammys 112" rod Use #14SW Nut Driver(Item #101) Model Screw Ikseriltion Minimum Thickness Maximum Thickness Actual Shear/Pullout I3oxQty Weight per 100) CaseQtyESWD1001/4-14x1 066"-16ga 1/4" 1477#116ga too 600 1000 SWD200 1/4-14x2 066"-16ga 1/4" 1477#/161yi 100 6.50 1000 SWDR 100 1/4-20 036"-20 ga 1/4" 1900# / 20 too 6.00 1000 Use 914SW Nut Driver (Item #101) Approval Iten1# Model Screw Descri ion UU'rest Ioadlb. UIJFM Pi Sire Minimum Thickness Maximum Chickness Actual Shear/Pullout I3oxQty Weigh per 10( NFPA 39 SWD 10 1/4-140 1.066"-16 ga 114" 1 1477# / 16 ga 100 6,00 NJ; 11A 40 SWD 15 1/4-140 1/2 Nate: S'CY1{n"fllfintetNrriA through wSll'li'200" i lC tG JfM[aJtCd,%GMc 1V%I It%I ry lin +'thl OnlytheE 101gi`bs wrgN ; 100 7.50 NFPA 41 SWD 20 1/4-14X2 100 6.50 NFPA 42 SWD516 5/16-18x[ 1/4 too 7.00 Ut.-NFPA 46 SWDR 1 1/2" 1/4-200 1/2 15000 4 25%U4" I/2" 2375#/.25"-1/4" 100 7.25 1 t z a r4 i ,r ....... Ut,NVI'A 44 SWDR 516 5/16-180 114 1500# 4 036"-20Jp I/4" 24800120ga 100 8.25 5- .,..,^ i` 2-4 fl...1 2_", 77.... R°°.-.(n 'x.._ i/2-:..'... rl... R L PERFORMANCE DATA FOR STEEL. SHEET STEEL GAUGES Gauge No. 1/4 3/16 12 14 16 18 1 20 1 22 1 24 1 26 Decimal Equivalent 1 .25 188 105" 075" 060" 048" 1 .036" 030" 1 .024" 1 .018" Ultimate Pullout Values - Samm s average lbs. ultimate) Fastener Steel Gauge Model Dia. Pt. 20 18 1 16 1 14 12 1 3/16 114 DST 1/4 3 446# 613# 1 970# 1 1145# 1544# 3190# DST 516 5/16 3 457# 568# 1209# 1712# 2422# 3716# TEK 50 12 5 487# 699# 913# 1527# 3270# 3593# DSTR 1 1/2" 12 5 1 3270# 3593# DSTR 1" 1/4 3 1510# DSTR 516 5/16 3 12200#1 Ultimate Shear / Pullout Values - Sidewinders average lbs. ultimate) Fastener ISteel Gauge Model Dia. Pt. 1 20 18 16 1 14 12 3/16 1/4 SWD 114 3 1477# SWDR 1 1/2" 12 5 2375# SWDR 1.. 1/4 3 1900# 19001t SWDR 516 5/16 3 2480# 2480# Aluminum Curtain Wall Extrusion Ultimate Pullout Values average lbs. ultimate) Fastener Thickness Model Dia. Pt. 114 092 365 132 DST 10 1/4 1 #3 12651t 2750# SWD 10 114 3 1120#1 1420# For fasteninglanchoring its high vibratory environments, consult local code authorities for accepted anchoring devices Note: Scren s must be inshraed ralth upproprin[e-1,16rer w enrtrplyn-ith,,,,—rty Page 7 0 r4 =071L Sammys/Sidewi-nders Pullouts listed are average actual pullouts and should be used as reference only for calculations of acceptable pullout and shear values. Values are ultimate averages achieved Linder laboratory conditions and apply to fasteners manufactured by Speedy Products, Inc. only. In the process of doing engineering, design personnel should divide by the recommended safe load average per the industry requirement. NFPA 132-6.1 ----1,'ireprotectiotif*,istening requirements: Five times the weight of the water filled pipe plus 250lbs. Example: Based on 15 ft. of 3" pipe (schedule 40). Wt of H2O (#/gal) x Gallft (.- 11 WVft of HP 8.34# X .3840 3.20# Pipe wt/ft - I H2O W11ft = Water filled pipe wL/ft 7,575# 3.20# 10.775# Water filled pipe wt/ft x Pipe Lgth Actual wt. per 15 ft 10 . 775# X 15' 161.63# Safety Factor x Actual WL - 250# Safety Load 5 x 161.63# + 250# = 1058# Steel Screws Due to variations in hardness of certain metals, it should be noted our self -drilling screws for steel will experience I IYerent drill rates. 500-1500 RPM drill speed should be tried. Resulting drill chips should not be blue in color. Residual dri It chips that are blue in color indicate the drill RPM level is too high. NFPA Requirements Sammy screws noted with NFPA under "Approvals" column meet NFPA requirements. Check with local Authority Having Jurisdiction to confirm application and usage. Page 20 0 1/2"-2" IPS Angle Globe Valves, UL/ULC Listed* 300 psi Fire Protection Products, Inc, 6241 Yarrow Dr., Suite A, Carlsbad, CA 92009-1541 Description Manufactured from cast brass, our angle valves are for Trim or Drain applications and are designed to be suitable for all sprinkler systems including high pressure systems. The soft seat design utilizes NBR Nancar N70 material for posi- tive sealing to 300 psi. The most common use for the 2" IPS size is as a system drain at the riser. May be used on both alarm valve and shotgun type riser assemblies. UL/ULC Listed, 2R97 Installation Installation of the Trim/Drain valves can be accomplished using normal installation methods. Use a suitable thread sealant such as PipeFit Thread Sealant with PTFE* or PTFE*Tape to assure a positive seal be- tween the valves and the installed pipe. Caution: Do not over - tighten male threads into the valve body. Thread damage or cralking of the valve body may occur. PTFE is the chemical equivalent of Teflon® Teflon is a registered trade- mark of DuPont. @1996-2002 Fire Protection Products, Inc. Specs Materials Cast Brass: Body Bonnet Brass ASTIVI B 16: Gland Holder Stem Washer Stainless Steel: Nut NBR Nancar N70 Rubber seat JIS FC20: Hand wheel Sizes: 1/2" IPS FxF 3/4" IPS FxF 1" IPS FxF 1 1/4" IPS FxF 1 1/2" IPS FxF 2" IPS FxF For questions: 1 800 344-1822 1 800 344-3775 fax http:/ANww.fppi.com TrimFito Bronze Globe Valve with Teflon* Seat, UL/ULC Listed 300 psi Description FPPI TrimFitO Bronze Globe Valves are precision cast then machined using state of the art facilities. Each valve features a full floating seat holder for reduced seat wear when clos- ing the valve. Seat is made of pure virgin Teflon* for longer seat life and reduced mainte- nance as compared to rubber seat valves. TrimFit trim valves are suitable for use in regular 175psi) and high pressure 300psi) sprinkler systems. Standard configuration is FNPT x FNPT and is available in 1/4" IPS through 2" IPS sizes. Each valve carrries the UL Listing and is rated for use to 300psi. UL/ULC Listed 2R97 Installation Install in accordance with usual and customary installation techniques for fire sprinkler systems. Use a suitable thread sealant on the male threads of the pipe being threaded into the valve body. We recommend either TeflonO* tape or PipeFitO Thread Sealant Paste with PTFE. (PTFE is the chemical equivalent of Teflon*) DO NOT OVERTIGHTEN. OVERTIGHTEW ING MAY CAUSE CRACKS OR LEAKS. Teflon(D is a registered trade- mark of DuPont. PipeFit@, TrimFit® are regis- tered trademarks of Fire Protec- tion Products, Inc. IF P P I F FI,07KTION 01li OS - 2000-2002 Fire Protection Products, Inc. specs Material: Brass or bronze Seat -Teflon* Hand wheel-JIS FC-20 painted red. Sizes: 06-7981/4" IPS FNPT 06-8001/2" 06-802 3/4" 06-8041 " 06-806 11 /4" 06- 808 11 /2" 06-810 2" For questions: 1 800 344-1822 1 800 344-3775 fax http://www. fppi.com info@fppi.com INTUMESCENT SEALANT APPLICATIONS PRODUCT DESCRIPTION SpecSeal@ LCI Sealant has a broad application base designed to seal a wide variety of common penetrations in light commercial and grouped residential construction. Penetrant types include insulated and non -insulated metallic pipes and tubes, non-metallic pipes and tubes, and common electrical service and power distribution, telephone, data, and TV cabling. This product is also used in conjunction with other SpecSeal@ Products such as SpecSeal@ Firestop Collars and Wrap Strips to protect larger plastic pipes. See Table A for a summary application list. PHYSICAL PROPERTIES Properties Series Lai Color Red Odor Mild Latex Density 9.0 ibigal (1.08 kgt) pH 9.0 In Service Temperature s 185°F (85'G) Flame Spread 0" Smoke Developed 5. STC Rating 62 ASTM E90/ASTM G919) VOC Content 029bsgal (35,Ogtl EPA Method 241ASTM D3%0) Shelf Life 2 yrs Volume Expansion IOX Free Expansion Storage Temp. 4WF (4°C) -95`F (3K) Tested to ASTM E84ttR723}atW.surfacewmage(n edtestfor sealants and cauks) SpecSeal@ LCI Sealant is a versatile and economical intumescent product intended for firestopping a wide array of applications in small commercial or grouped residential construction and other structures with similar applications. SpecSeal@ LCI Sealant is available in a single grade that has excellent caulk- ing properties as well as high build properties on vertical or overhead surfaces. This single grade may be caulked (standard cartridge or bulk loaded), knifed or troweled. In addition, SpecSeal@ LCI Sealant does not contain PCB's or asbestos, SpecSeal@ LCI Sealant is storage stable (when stored according to the manufacturer's recommenda- tions), and will not separate or shrink when dried. SpecSeal@ Series LCI Sealant will adhere to all com- mon construction and penetrant materials and contains no solvents that might adversely effect plastic pipes or cable jackets. Economical: High performance without the high price! Highly Intumescent: Expands up to 8 times. Excellent Smoke Seal Water Resistant: Will not re -emulsify when dry. Water -Based for easy installation, cleanup, and disposal. Acoustically Tested: Reduces noise transmission Safe ... Low VOC's, No Solvents, Non -Halogenated Paintable PERFORMANCE SpecSeal@ LCI Sealant is the basis for systems that meet the exacting criteria of ASTM E814 (UL1479) and ASTM E 1966 (UL2079) as well as to the time -temperature requirements of ASTM E 119 (UL263). LCI provides up to a 4-hour fire rating for typical service penetrations through concrete or wood floors, concrete or masonry walls, as well as gypsum board walls. SpecSeal@ LCI Sealant meets Class A finish require- ments for Flame Spread and Smoke Development when tested in accordance with ASTM E84 (UL723). SpecSeal@ LCI Sealant is also acoustically tested, demonstrating excellent sound attenuation properties. FBCT" System Compatible Indicates that this product has been tested, and is monitored on an ongoing basis, to assure its chemical compatibility with FlowGuard GOIcK, BlazeMasterlD and CorzanO pipe and fittings. FBC, FBC%,;"` SYSTEM COMPATIBLE FIOWGuard Gold, BlazeMaster and Corzan are licensed trademarks of The Lubrizol Corporation. 4QSSIFjF FILL, VOID OR CAVITY MATERIALS FOR USE IN JOINAAND4OANDTHROUGH -PENETRATION FIRESTOP SYSTEMFM DIRECTORYOFPRODUCTSCERTIFIEDFORCANA1UfLusFIRERESISTANCEDIRECTORY.APPROVER 31.73 SPECIFICATIONS The firestopping sealant shall be a water-resistant, intumescent latex sealant. The sealant when exposed to high heat or flame shall exhibit a free expansion of up to 8 times its original volume. The firestopping sealant shall contain no water soluble nor hygroscopic ingredients and shall be acoustically tested. The sealant shall be UL Classified and/or FM approved and tested to the requirements of ASTM E814 (UL1479) and shall meet Class A finish requirements when tested in accordance with ASTM E84 (UL723). SPECIFIED DIVISIONS DIV. 7 07840 Through -Penetration Firestopping DIV. 13 13900 Special Construction Fire Suppression & Supervisory Systems DIV. 15 15250 Mechanical Insulation — Fire Protection DIV. 16 16050 Basic Electrical Materials & Methods Technical Service 1-800-992-1180 STI• www• stifirestop.com STI Product Data Sheet • Series L(I Intumescent Sealant • FOD-5062 05/2011 Fig 1: METALLIC PIPES - Concrete/Masonry Floors & Walls Fig 2: INSULATED METALLIC PIPES - Concrete/Masonry Floors & Walls MotallicLCI LCI Pipe Sealant~ Concrete Metallic LCI Pipe Sealant _.._ Mineral ° Wool Steel Sleeve LCI Sealant SteeShove \ Floor Sealant Steel Concrete n Floor Both Sides) MineralWool 4 Mineral Wool Concrete Insulated Pipe Concrete Wall Insulated Wall Assembly MetallicPipe UL System No. C-AJ-1353 UL System No. W-J-1098 UL System No. C-AJ-5138 F Rali g: 3 Hr • T Rating: 0 Hr F Ratting: 2 Hr • T Rating: 114, 314 & 1 Hr F Ratting: 2 Hr • T Rating: 314 or 1 Hr Steel or Iron Pam: <12", Copper Pipe: 4' Steel or Iron Pipe: 4'. Copper Ppe: <4" Steel or Iron Ppe: 6", Capper Pipe: 4" Amdis: (Y" to 2" Annulus: 0" to 2" Ppe Covering: Max. Z'fbff glass or mineral wool pipe Insulation. Sealant Depth: 114" Sealant Depth: W' Annulus: 1/4" to I-,W • Sealant: 1/7' Forming Material: Nom 4 pd mineral wool (21/4" Depth) Forming: Nom. 4 pd mineral wool IT 41h) SEALANT REQUIREMENTS IN CUBIC INCHES PER 1l4 INCH OF INSTALLED DEPTH' Pipe Size Diameter of Opening (in.) L5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10 12 14 26 Tiede Pipe Sr. O.D. 0.611 0 840 0.3 0.6 1.6 3 0 4.8 6 9 9 5 12 4 19 5 28 1 38 3 132 6 04IcroM 1" 1.315 0.1 O A 1 A 2 8 4,6 6 7 9 3 12 2 19 3 27 9 38 1 132.4 Sealant 0egh? 2 Mulyty N 2 1.5" 1.900 1.1 2 4 4.2 6.4 8.9 11.9 18.9 27.6 37.8 132.0 5,9' Mrktpliby2.5 T. 2.375 0.7 2.6 3.8 6.0 8.5 11.5 18.5 27.2 37.4 131.6 1" Muliplytry4 2.V 2.875 0.1 1.5 3.3 5.4 8.0 10.9 18.0 26.7 336.9 131.1 1-1/4" Mul#ytry5 T. 3.500 0.7 2.5 4.7 7,2 10.2 17.2 25.9 361 130.3 3.5" 4,000 1.8 3.9 G5 9. 4 16.5 25.1 35.3 129.E 4" 4,500 0.8 3.0 5.6 8.5 15.6 24.2 34.4 128] 6" C 25 11 4.0 11.1 19.7 29.9 124.2 8" 8.625 4.9 13.6 23.8 118.0 t0" 10.750 5.6 15.8 110.0 12" 12,750I'll ----- 6.6 100.8 24" 24.000 19.6 IMPORTANT NOTE. This table is for estimation purposes ony. Consul UL Fire Resistance Directory or STI Product & Application Guide for specific installation requirements and limitations Metric Estimation Table available upon request, Fig, 3: ELECTRICAL, DATA OR COMMUNICATIONS - Gypsum Walls Cable LCI Sealant LCI Sealant Bundle (Both Sides) Non -Metallic (Both Sides) Conduit 10:5-0- Gypsum Wallboard Gypsum Assembly Wallboard Assembly UL System No. W-L-3169 UL System No, W-L-2241 F Rating: 1, 2 Hr • T Rating: a and a F Rating: 1, 2 Hr • T Rating: 0, a,1,1-314 Up to 4-1/2" cable bundle <2" Rigid PVC or ENMT, CPVC, ABS Annulus: O" to a" • Sealant: 5/8" Annulus: 0-1"• Sealant 5/8" STI Product Data Sheet • Series KI Intumescent Sealant • FOO-5062 05/2011 TABLE A: APPLICA110NS TESTED AND CLASSIFIED FOR FIRE RESISTANCE Metallic Pipes including steel, iron, or copper pipe and tubing. Nonmetallic Pipes, Conduits & Tubing including PVC, CPVC, ABS, and PEX. Electrical & Electronic Cabling including service entrance, power distribution, computer, telephone, and television. Metal Ductwork including HVAG, bath and dryer vents. Insulated Pipes including heating, cooling, and condensation applications. Complete Wood Floor firestopping package for electrical, plumbing, HVAG, telephone, and television. Technical Service 1-800-992-1180 = www.stifirestop.com STI, INSTALLATION INSTRUCTIONS GENERAL: Areas to be protected must be clean and free of oil, loose dirt, rust or scale. Installation temperatures must be between 35°F (2°C) and 100°F 381C). Allow product to dry a minimum of 24 hours before exposure to moisture. SYSTEM SELECTION: Selection of an appropriate firestop system design is critical to the fire protection process. Space limitations preclude highly detailed information pertaining to individual application systems. Please consult the Product & Application Guide as well as the UL@ Fire Resistance Directory for additional information. FORMING: Some installations may require forming as either an integral part of the system or as an option to facilitate installation. In systems where forming is required, mineral wool batts with a minimum nominal density of 4 PCF (64 kg/m') are generally required. Cut forming material oversize to allow for tight packing. Position forming material to allow for the proper depth of fill material. FILL MATERIAL: SpecSeal@ LCI Sealant may be installed by caulking using a standard caulking gun or from bulk containers using a bulk loading caulk gun, or by manually troweling using a mason's trowel or putty knife. If the sealant tends to pull back from a surface, clean the surface with a damp rag or sponge and reapply. Work sealant into all areas exercising care to eliminate voids or seams. The surface of the sealant can be smoothed using a putty knife dipped in water. Adding water to the sealant itself is not recommended. Sealant (when dry) may be painted using most non -solvent based paints. Fig. 4: BARE & INSULATED METALLIC PIPES - Wood Floor Assemblies Metallic Insulated Metallic Pipe LCI Sealant LCI Wood Floor Sealant Assembly UL System No. F-C-1074 F Rating: i & 2 Hr • T Rating: a, a and 1 Hr Steel, lion or Copper: 4" • Chase wall optional. Annulus: 0- to 1- • Sealant: 5/8" bottom, a" top UL System No. F-C-5043 F Rating: i& 2 Hr • T Rating: a and 1 Hr Steel, Iron or Copper: 4" Pipe covering: 1"Fiber Glass, Mineral fiber or AB/PVC • Chase wall optional. Annulus: 0" to i" • Sealant: 5/8" bottom, a" top. Fig. 5: BARE & INSULATED METALLIC PIPES - Gypsum Walls Metallic LCI Sealant Pipe ( Both Sides) tL Gypsum Wallboard Assemblyr UL System No. W-L-1222 F Rating: 1, 2 Hr • T Rating: a, a, 1 Hr Steel or Iron pipe: 8-, Copper pipe: 4" Annulus: 0- to 2" • Sealant: 5/8" STD Insulated I I I I I I LCI Sealant Metallic (Both Sides) Gypsum Wallboard ffUAssembly UL System Nos. W-L-5121, W-L-5122 F Rating: i, 2 Hr • T Rating: 1 Hr & i/4 Hr Steel or Iron pipe: 6-, Copper pipe: 4- Pipe covering: Max. 2-fiber glass, a" AB/PVC or 2- mineral fiber Annulus: 0" to 1-1/2- • Sealant: 5/8" In gypsum wallboard penetrations, apply a minimum cove bead of 1/4" (6 mm) at the interface of the penetrant with both exterior wall surfaces. SMOKE SEALING: In some applications including firestop collars, SpecSeal@ LCI Sealant is recommended as a smoke seal. It is suggested in these applications that the sealant be applied to both sides of walls. In floor applications, a sealing bead is suggested top and bottom. LIMITATIONS: SpecSeal@ LCI Sealant is water - based and cures through the evaporation of water. Low temperatures as well as high humidity may retard drying. Non -porous or impermeable backing materials, plates, or coatings may retard the drying process. Do not paint or seal in any way that pre- vents contact with air until sealant has dried through completely. This product has been designed to be safe with plastics and has been used extensively and successfully with a variety of different types of plastic pipes, tubes, and plastic cable insulations. Variations in these materials however, make it impossible to guarantee compatibility. STI strongly recommends that the user consult with the manufacturer of the pipe, tubing, or cable in question regarding any known sensitivities or potential restrictions before applying this product. LCI Sealant Both Sides) AC Line Set Assembly UL System No. W-L-8025 F Rating: 1, 2 Hr • T Rating: a Hr AC Line Set: Two copper tubes, one with a" AB/PVC and thermostat wire Annulus: 0" to i" • Sealant 5/8" Technical Service 1-800-992-1180 STI Product Data Sheet • Series L(I Intumescent Sealant • FOO-5062 05/2011 www.stifirestop.com MAINTENANCE No maintenance is normally required, however a periodic inspection of rated barriers is recommended to make sure that any new openings, modifications of previously installed firestops, or, areas exhibiting physical damage, have been properly sealed or repaired. Subsequent sealing or repairs should be accomplished using SpecSeal® products per the original approved design. RETROFIT: When adding or removing penetrants, care should be taken to minimize damage to the seal. Reseal using SpecSeal@ products per the approved design. NOTE: New penetrants of a different nature than the original design may require a totally new Firestop design or extensive modifications to the existing design. Reseal all openings as per the requirements of the modified design. TECHNICAL SERVICE Specified Technologies Inc. provides toll free technical support to assist in product selection and appropriate installation design. UL Systems, Material Safety Data Sheets and other technical information is available through the Technical Library at www.-tifirastnn rnm. PRECAUTIONARY INFORMATION Consult Material Safety Data Sheet for additional information on the safe handling and disposal of this material. AVAILABILITY SpecSeal® Series LCI Sealant is available from authorized STI distributors. Consult factory or website for the names and locations of the nearest sales representatives or distributors. CAT. NO. DESCRIPTION LC1300 Sealant 10.1 oz Tube 18.2 Cu In (300 ml) LC1305 Sealant 5 Gal Pail 1,155 Cu In (19.0 Liters) LC1320 Sealant 20 oz Sausage 36 Cu in. (592 ml) LCI329 Sealant 29 oz Quart Tube 52 Cu in. (858 ml) AdrtilrktW sp ecsea f Preotfdsw Series SSS Sealant The industry's most versatile sealant provides the firestopping solutions for a wide range of combustible and noncombustible applications. Water -based intumescent sealant expands up to 8X! IMtanescerd Wrap Strips Three grades of intumescent wrap strips provide an unmatched combination of flexibility, economy, and expansion (up to 30x). Systems for plastic pipes including FIR Polypropylene up to 8" trade size! SSC & LCC Firestop Collars Easy to install, economical protection for ABS and PVC pipes (both solid and foam core) as well as CPVC, PVDF, and FRPP. LCC Collars are available up to 4" and SSC Collars are avail- able up to 6` trade size. Firestop Mortar Lightweight, versatile and economical! The best choice for large or complex installations. SSP Firestop Putty Available both in bar form and in pads, putty provides easy retrofit for through -penetrations and economical protection for electrical boxes. Pensil@ Silicones Sealants and foam for through -penetrations and construction joints. Unexcelled aging charac- teristics and flexibility. Elastomeric Joint Seals New economical products for sealing construction joints, Choose caulk or spray applied products tested to UL2079, IMPORTANT NOTICE: All statements, technical information, and recommendations contained herein are based upon testing believed to be reliable, but the accuracy and completeness thereof is not guaranteed. WARRANTY Specified Technologies Inc. manufactures its goods in a manner to be free of defects. Should any defect occur in its goods (within one year), Specified Technologies Inc., upon prompt notification, Will at its option, exchange or repair the goods or refund the purchase price. LIMITATIONS AND EXCLUSIONS: THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS EXPRESSED OR IMPLIED (INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE) AND UNDER NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC. BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL PROPERTY DAMAGE OR LOSSES. PRIOR TO USE, THE USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE, AND THE USER ASSUMES ALL RISKS AND LIABILITY FOR SUBSEQUENT USE. No statement or recommendation not contained herein shall have any force or effect unless in an agreement signed by officers of seller and manufacturer. MADE IN THE USA — COPYRIGHT © 2011 SPECIFIED TECHNOLOGIES INC. Specified Technologies STI Inc. Specified Technologies Inc. • 210 Evans Way, Somerville, NJ 08876 USA • Phone: 800.992.1180 • Fax: 908.526.9623 STI Product Data Sheet • Series LG Intumescent Sealant • FOD-5062 05/2011 Technical Service 1-800-992-1180 www.stifirestop.com STI. Revision 0 Response to Comments 53/ iCity of Sanford ilding & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Permit# 1 K—)LI I z 1-11 Submittal Date S// Project Address: IKO CL F— 32271 Contact: Zo 1-1 Ph: -IoJ Y 7 - 6 c- S Email: Trades encompassed in revision: El Building Plumbing Electrical El Mechanical El Life Safety 11 Waste Water Department Fax: S'l , j t200 General description of revision: ROUTING INFORMATION El Utilities 1-1 IT Waste Water Jr 0 Planning El Engineering 11 Fire Prevention El Building Approvals Revisi ;, z on Response to Comments 1% Permit4 Project Address:. Contact: A/t 'To /-t / Submittal Date Ph: - " tq 7 - `,0 e - -3,5 7 5— Fax: Email: ^A'T-F 0 P0 I Lee CQ-5-„TVC'7-fe,-, 'O"t Trades encompassed in revision: wildinglI Plumbing 11 Electrical 11 Mechanical El Life Safety 11 Waste Water Department Utuitiesu' Waste Water El Planning El Engineering City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov 0 General description of revision: ROUTING INFORMATION El Fire Prevention uilding -I- -7r-:-4 Approvals 0 M&T p CITY OF SANFORD FIRE DEPART'MENT Building & Fire Prevention Division PERMIT APPLICATION Application No: - 0 0 _2_' Documented Construction Value:$ 17,350.00 Job Address: 1810 Rinehart Road &101 - t 702 Historic District: Yes[:]NoR] Parcel ID: 29-19-30-512-0000-0010 Residentiac] Commercial Type of Work: NewD Addition Alteration® Repair Demo[] Change of UseF]Move n Description of Work: install new fire alarm system Plan Review Contact Person: Bill Romine Title:CCBW Phone: 321-377-2115 Fax: 407-982-7235 Email: billromine@cfl.rr.com Name 1810 Rinehart LLC Street: 1810 Rinehart Rd City, State Zip; Sanford, Fl, Property Owner Information Phone: Resident of property? : Contractor Information Name Alliance Fire Protection Services Corp Phone: 321-377-2115 Street: 1932 Caladium Place Fax: 407-982-7235 City, State Zip: Longwood, Fl, 32750 Name: Street: City, St, Zip: Bonding Company: Address: State License No.: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction 11inthisjurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, beaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6" Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Le 2 Signature of Contractor/ Ocrif Date L-0 wl, I KZ Print Contractor/Agent's Name 0 S_tYre of Notary-State-o`17 Florida Date HEIDI SCOTT Notary Public - State of Florida Commission 9 GG 7 14390 My Comm. Expires May 6, 2022 ContrhMr;1T7Tgcr1t" — — 9 emunmNymWown to Me or Produced ID Type of ID _ E L-0 L BELOW IS FOR OFFICE USE ONLY Permits Required: Building[] ElectricaIE] MechanicalE] PlumbingF1 Gas[:] Roof[] Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: YesEl No R #of Heads Fire Alarm Permit: Yes[] No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIR i BUILDING: COMMENTS: Revised: January 1, 2018 Permit Application DATE(NIWDDrYYYY) ACQ"REP CERTIFICATE OF LIABILITY INSURANCElla. r O7/05/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate, holder In lieu of such endorsement($). PRODUCER CONTACT NAME: Robert Sistrunk Heart Of Florida Insurance Group! Ocala PHONE 352 394-4884 2801 SW College Road E Suite 3 INSURER(S AFFORDING COVERAGE NAIL S OGala FL 34474 INSURERA OM1-NORGUARD INSURED INSURER B : j Alliance Fire Protection Services Corp INSURER C : 1932 Caladium Place I tNAI IRFR n I Longwood FL 32750 IINSURERF: I I COVERAGES CERTIFICATE NUMRER- REVISION Nt1MRFR- THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. POLICY EfF P4LIY EXP—_.__._ IN§t __m__ADDL LIMITS...____._._.__.._.I_- LTRTYPE OF INSURANCEMORF POLICY NUMBER COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ MXGETO RENTr.D__.__- _ w..__.. i ra CLAIMS MADE OCCUR PREMISES (Ea ocxumencel.----- ------ _- ----------- MED EXP (Any one person) __.. $ I PERSONAL & ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE_ $ E, PRO POLICY LOC PRODUCTSWCOMR/OPAGG $ OTHER: AUTOMOBILE LIABILITY Ea BINEDtj—, SINGLELI IT$ ANY AUTO BODILY INJURY (Per person) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY (Per accident) $ NON -OWNED PROPERTY QAMAGE^ $ HIRED AUTOS, AUTOS i Rer accident_ _ UMBRELLA LIAR OCCUR EACH OCCURRENCE S y EXCESS LIAB I CLAIMS -MADE AGGREGATE S DED RETENTION $ WORKERS COMPENSATION H- AND EMPLOYERS' LIABILITY Y/ N 1 STATUTE ANY PROPRIETORIPARTNERIEXECUTIVE A OFFICER/MEMBER EXCLUDED? N / A) ALWC706605 E.L EACH ACCIDENT $ 1,000,000 07/01/2018 07/01/2019 ' ' -......._ Mandatory In NH) E.L. DISEASE - EA EMPLOYE S 1,000,000EMPLOY-- If yyes, describe under 0 SCRIPTION OF OPERATIONS below i I-— ----DISEASE-- ..__ -— — E.L. DISEASE - POLICY UM17 $ 1,000,000 I DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Addltlana! Remarks schedule, may be attached If more apace Is required) Burglar & Fire Alarm Installation & Repair CERTIFICATE HOLDER r_ANrFI I ATICIN SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN City of Sanford ACCORDANCE WITH THE POLICY PROVISIONS. 300 N. Park Ave. AUTHORIZED REPRESENTATIVE Sanford, FL 32771 Robert A. Sistrunk building@sanfordfl.gov 01988-2014 ACORD CORPORATION. All rights reserved. ACORD 25 (2014101) The ACORD name and logo are registered marks of ACORD RICK SCOTT, GOVERNOR KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ELECTRICAL CONTRACTORS LICENSING BOARD LICENSE NUMBER If'If The ALARM SYSTEM CONTRACTOR I Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2018 SEQ # L1606290001028 EMUNbraE COUN - ; SUSMESS TAX RECEIPT VALID THROUGH 09/30/18 ALLIANCE FIRE PROTECTION SERVICES CORP 1932 CALADIUM PL LONGWOOD, FL 32750 WILLIAM J ROMINE (PRESIDENT) Account #: 121096 REGULATED License # - EF20000371 Qualifier- ROMINE WILLIAM JOHN Receipt #: 10272017092611885 Amount Paid: $ 45.00 Date Paid: 09/26/2017 PT_QR_Q_r_ty_R9_q_ r_q or Parcel: 29-19-30-512-0000-0010 Property Address: 1810 RINEHART RD SANFORD, FL. Parcel Information Value Summary Parcel 29-19-30-512-0000-0010 Owner(s) 1810 RINEHART LLC Property Address 1810 RINEHART RD SANFORD, FL Mailing: 6701 FRANRIVERS, AVE WEST HILLS, CA 91307- Subdivision Name MiN CQ_M_MD_N_* Tax District SI-SANFORD DOR Use Code 11-STORES GENERAL -ONE STORY Exemptions x as 01 Legal Description LOT 1 SEMINOLE COMMONS PB 80 PGS 8 & 9 Taxes Taxing Authority Assessment Value County General Fund Schools City Sanford SJWM(Saint Johns Water Management) County Bonds Sales Description Date Book Page SPECIAL WARRANTY DEED 11/1/2016 2018 Working 2017 Certified Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value 1.556,234 1,464,292 Depreciated EXFT Value 151,951 154,757 Land Value (Market) 1,200,025 1,165,073 Land Value Ag 2,908,210 2,784,122 Portability Adj Save Our Homes Adi 0 0 Amendment I Adj 0 0 P&G Adj 0 0 Assessed Value 2,908,210 2,784,122 Tax Amount without SOH: $53,013.00 53,013.00 72x E S _t, nI I —t(Lf Save Our Homes Savings: $0,00 Does NOT INCLUDE Non Ad Valorem Assessments Exempt Values 2.908,210 2,908,210 2,908,210 2,908,210 2,908,210 Taxable Value 0 2,908,210 0 2,908,210 0 2,908,210 0 2,908,210 0 2,908,210 Adj Value Repl Value Appendages 1,556,234 $1,778,553 Description Area OPEN PORCH 1256.00 FINISHED Permits Permit # Description Agency Amount CO Date Permit Date 01702 INTERIOR & EXTERIOR REMODEL SANFORD 673,190 6/6/2018 01413 DEMO INTERIOR SANFORD 19,000 3/29/2018 Permit date doer not o"gineb from the Seminole county Properly Appraiw's offfm For deSeft or Ou"Oom concerning a permit, phase contact ire building depertmwn of the tax dlNrlct in which the property to located. Extra Features Description year Built Units Value New Cost WALKS CONC COMM 1/112008_. 2,785 6,914 9,218 POLE LIGHT STEEL 5 ARM 1/112008 3 21,570 21,570 POLE LIGHT STEEL 4 ARM 1/1/2008 6 33,798 33,798 POLE LIGHT STEEL 2 ARM 1/1/2008 3 7,560 7,560 POLE LIGHT STEEL 1 ARM 1/1/2008 5 4,820 4,820 LOAD WELL 1/1/2008 2,278 2,563 3,417 COMMERCIAL ASPHALT DR 3 IN 1/1/2008 81,668 74,726 99,635 •. 00mviam= General Contractor SUBCONTRACT AGREEMENT Date: 6/27/18 This agreement is between Contractor: Project Name: Attitude Trampoline Park Project Address: 1810 Rinehart Road Philco Construction and Develpment, LLC. Sanford, FL 32771 114 N Park Ave. Sanford, FL 32771 Contract Amount• $17,350.00 and Subcontractor: Alliance Fire Protection Services Corp. 1932 Caladium Place Longwood, FL 32750 Article I- Scope of Work For the sum set forth above, the above named subcontractor agrees to install and perform all work outlined in both attachements "A" & "B" in compliance with the project plans and specifications, and to furnish all cleanup related to its work. Subcontractor agrees to perform the work in a complete and professional manner, to meet or exceed industry standards for all work performed, and to perform the work in accordance with the contractors schedule. Subcontractor further agrees to notify the contractor of any long lead-time item, which may have an effect on the completion schedule of the project. In addition, be advised that purchase and/or procurement of materials prior to submitted approval are at the subcontractor's own risk. Article 11- Contract Payment The Contractor, Philco Construction & Development, LLC., agrees to pay the Subcontractor progress payments for satisfactory completion of Subcontractor's work. 114 N. Park Ave Sanford, Fl, 32771 Phone 407-647-7445 State License ft CBC 1260967 Progress payments, less retainage of 10%, shall be made to the Subcontractor for work satisfactorily performed. Subcontractor shall submit a progress billing to the Project Manager by the 201' of the month, for the work completed prqJjected thru the last day of the month. Payment to be made Ten 10) days after receipt of payment from the owner. Final payment to be made Ten (10) days after receipt of final payment from the Owner. Article III -Insurance Subcontractor agrees to have in force and effect from the date of the contract, and to its completion, insurance coverage's at least to the following minimums; A. Worker compensation and employers liability insurance. Such policy to include where applicable, provisions for benefits under the United State's Longshoreman's and Harbors work act. B. Commercial automobile liability insurance covering all owned, non -owned, and hired automobiles subject to a minimum combined single limit of $1,000,000 for bodily injury and property damage liability. C. Comprehensive general liability insurance subject to minimum limits as follows: General Aggregate: $2,000,000 Completed operations aggregate: 2,000,000 Personal/averting injury: 1,000,000 Each Occurrence 1,000,000 Inclusive: products and completed operations, personal injury, broad form property damage, and contractual liability (recognizing the provisions of #5 below). D. For the purposes of this contract: Philco Construction & Develpment, LLC. is to be added to the subcontractor's policies as an additional insured; The subcontractor waives their insurer's right of subrogation against Philco Construction & Development, LLC. A Subcontractor's insurance shall be primary and non-contributory. Article IV -Guarantee and Warranty Subcontractor agrees to guarantee and warranty his workmanship for not less than one year from the date of final acceptance of this project. 114 N. Park Ave. Sanford F1,32771 Phone 407-647-7445 State License #CRC' 1260967 N Article V-Flow Down Provision Subcontractor shall assume toward the contractor, all obligations and responsibilities, which the contractor assumes toward the owner. Subcontractor is bound to the owner, including without limitation, any guarantees and warranties. Subcontractors agree to bind all lower tier subcontractors and suppliers to the same terms and conditions as the subcontractor assumes to the contractor and owner. It is the responsibility of the subcontractor to obtain and be familiar with all contract documents, plans, and specifications, which govern or affect the work relationship between the owner and contractor. Article VI -Indemnification To the fullest extent permitted by law, the subcontractor shall indemnify and hold harmless Philco Construction & Develpment, LLC., its employees and assigns from and against all claims, damages, losses and expenses, including but not limited to attorney's fees arising out of the performance of or disputes arising out of this contract, provided that any such claim, damage, loss, or expense is 1) attributable to bodily injury, sickness, disease, death, or injury to, or destruction of tangible property, other than the work itself.); 2) Is caused in whole or in part by any negligent act or omission of the subcontractor and/or it's assigns. Article VII-Breach and Termination Should the subcontractor at any time breach any of its obligations under this agreement or any of the contract documents, plans or specifications, the contractor may issue a written notice of default. Within forty-eight hours of receipt of said notice, if the subcontractor has not taken action to correct deficiencies, the contractor may terminate the subcontract and complete the subcontractors work, either with its own forces or engage a new subcontractor to complete the work. Contractor may withhold payment and deduct the cost of completing the subcontractors work from any amounts due the subcontractor, and if the costs to the cost of completing the subcontractors work from any amounts due the subcontractor, and if the costs to complete said work exceeds the amounts due under the contract, seek compensatory damages against the subcontractor. Failure of the contractor to terminate the subcontractor as a result of a breach and failure to cure by the subcontractor in no way waives or restricts the right of the contractor to declare a default and/or terminate the contract as a result of future breaches by the subcontractor. Article VIII-Dispute resolution/Jurisdiction and Venue Any dispute arising out of this subcontract shall be referred to the American Arbitration Association to arbitrate under the construction industry arbitration rules applicable as of the 114 N. Park Ave. Sanford I1. 32771 Phone 407-647-7445 State License # CBC 1260967 3 date of this agreement* Unless, 1) the dispute involves a mechanics lien filed pursuant to chapter 13, Florida Statutes, in which case venue shall lie in the county where the real property is located. 2) The owner is party to the litigation, or 3) the contract documents provide for a different venue. Article IX -Interchangeability of Terms The subcontractor recognizes that Philco Construction & Development, LLC. may be acting as a subcontractor, in which case the subcontractor hereunder may actually be a sub -subcontractor. In that event, the term "contractor", may be interchangeable with "subcontractor" as the context requires, and the term subcontractor as used herein shall refer to the entity contracting at the tier below Philco Construction & Development, LLC. whether as a subcontractor or sub - subcontractor. Contractor: Philco Construction & Development, LLC. Signature Brian A. Borman, President Printed Name & Title 6/27/18 Date Subcontractor: Signature Printed Name & Title Date Federal ID # 114 N. Park Ave Sanford FL 32771 Phone 407-647-7445 State License#€ BC 1260967 4 CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION FIRE PLAN REVIEW SERVICE FEES PHONE: 407.688.5052 FAX: 407.688.5051 DATE: 7 r-4 PERMIT NUMBER: BUSINESS/PROJECT NAME: ADDRESS: /xio CONTACT NAME: PHONE: rF PLAN REVIEW INFORMATION CONSTRUCTION []C/O tIFIRE ALARM [] FIRE SPRINKLER []]HOOD, [ ]PAINT BOOTH DOES 20% REDUCTION IN FIRE IMPACT FEES APPLY: YESNQ TOTAL FEES: TANK DP-6V857a U L n S-20OX Intelligent Addressable FACP with Communicator by Honeywell I Addressable Fire Alarm Control Panels TxeES-20NX isthe latest Alarm Control Panel ( FACP) from Fire-Lite Alarms. The ES-20OX comes with a pre - installed communicator and supports up to 198 addressable devices ( 99 detectors and 99 modules). With an extensive list of powerful features, the ES-20OX programs just like Fire-Lite's other addressable products, yet fits into applications previously served only by conventional panels. The pre -installed \PUT8-COM isodual *mnhmd \P) communicator, The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network, The IP communicator's Internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL -MOD or CELL -CAB -FL. Remote and local programming ofthe control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk -test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on e circuit board supported on a new quick install chassis and housed in a metal cabinet. Available aome000hnm include |una| and mmnVu upload/download software, remote annunciators, and reverse mdop ity/city box transmitter (4XTMF). Featunos Listed ooVLStandard 8O4. 10tkedition Pre -installed |POTS-00K8Ethernet | Pand POTS (Plain Old Tele- phone Service) Central Station Communicator over /NannNe^ opuo"u| CELL -MOD or CELL -CAB -FL GSM Central GuaUun Communicator over Alamomet@ Automated activation of the ECC- 50/100 Emergency Command Center ECC-FFTFirefighter Telephone option Compatible with SYV|FTWwireless devices Auto - programming (learn mod*) m4u000 installation time. Reports two devices set mthe same address Four built-in, independently programmab| Style Z (Class A) o, Selectable strobe synchronization for System Sensor, Wheelock, and Genmmdevices Notification Appliance Circuit End oyLine resistor matching Four programmable function keys for ease ufmaintenance Two programmable relays and one fixed trouble relay Built- in Programmer Integral 80-chmo LCD display with backlighting Real-time clock/calendar with automatic daylight savings control History file with 1.000oven Addressable sounder base compatibility K4u| ti+crfteho detector (smoke, heat, CO) with programmable response Control module delay timer Automatic detector sensitivity testing (NFPx72compliant) Automatic device type -code verification Point trouble identification Wa(arflmwselection per module point Alarm verification selection per detector point Maintenance alert wmmowhen smoke detector dust accumula- tion is excessive One - person audible o,silent walk test with walk - test log and printout System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pre -signal per point (NFPA 72oompUonV Upm1VANN- BUSannunciators- Oper each ANN-Bwn Remote AuxnoWedga, Alarm 8||onue. Reset and Dd|| via addressable modules orremote annunciator Uplood8Juwnloadof programand data via USBwith optional FS- Too|uProgramming Utility SLC COMMUNICATION LOOP Supports LitaSpmad' and CLIP protocols SLCnperateo up to1V 0 ft. ( 3,000m)inLheSpoed mode with twisted, unshielded wire Single addressable SLC hop which meets NFRAClass B and Class Arequirements 190 addressable device capacity (89 addressable detectors and 9gmodu|oe) Compatible with Fine^LUe'uaddressable devices (refer tothe SLCWiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NACS) Four independently programmable outpu\cimu|to. Circuits can ueconfigured for the following outputs: Style Y( Class B) Style Z( Class A) Silence Inhibit and Au*ooi|mnoetimer options Continuous, March Time, Temporal, o, California code for main circuit board NACnwith two - stage capability Selectable strobe synchronization per NAC 258special application, 25OmAregulated, total power for NACa xOr Maximum mtotal u*VDC system power shared between allwwC circuits and the ANN-BUS is 2.7A oF-onomra^omxm10—Page Im* or PROGRAMMING AND SOFTWARE Autoprogramming (learn mode) reduces installation time Custom English labels (per point) may be manually entered or selected from an internal library file Two programmable Form-C relay outputs 99 software zones Continuous fire protection during online programming Program Check automatically catches common errors not linked to any zone or input point OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows@ -based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on zmw-filelilm.om- User Interface LED INDICATORS Fire Alarm (red) CO Alarm (red) AC Power (green) Supervisory (yellow) Trouble (yellow) Ground fault (yellow) Battery fault (yellow) Disabled (yellow) Maintenance (yellow) Communication (yellow) Alarm Silenced (yellow) FI-F4 Programmable Function Keys (yellow) KEYPAD 16 key alpha -numeric pad Acknowledge Alarm Silence Drill (Manual Evacuate) Four (4) programmable function keys Reset (lamp test) PRODUCT LINE INFORMATION ES-20OX: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pre -installed communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. (For ES-200XC, refer to DF-60958.) FS-Tools: Programming software for Windows( -based PC com- puter. Available for download at wwwfirelite&gM. CELL-CAS-FUCELL-MOD: Optional GSM communicators. POTS-COM: Dual technology (POTS and IP) communicator. replacement board) DP-ES-R: Optional dress panel for the ES-200X. TR-CE: Optional trim ring for semi -flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. SS-26: Batt" backbox, holds up to two 25 AH batteries and CHG- 75. BB-55F: Batt" box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi -modules in a BB•6F cabinet. CHG-75: Battery charger for lead -acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead -acid batteries with a rating of 55 to 120 AH. Requires additional BB-55F for mount- ing. SAT Series: Batteries, see data sheet DF-52397. PRN Series: UL listed compatible event printer. Uses tractor -fed paper. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. Increases alarm power output to 6 amps. COMPATIBLE ANNUNCIATORS ANN-80: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded, ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display, Recommended wire type is un- shielded. For use in FM applications only. ANN4/O: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure, (See DF- 60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANWRLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PG: SeriallParallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing, SD365: Addressable low -profile photoelectric smoke detector. Lite- Speed only. SD365-IV: Addressable low -profile photoelectric smoke detector, Ivory. LiteSpeed and CLIP mode. SD365T: Addressable low -profile photoelectric smoke detector with thermal sensor. LiteSpeed only. SD365T4V: Addressable low -profile photoelectric smoke detector with thermal sensor. Ivory. LiteSpeed and CLIP mode. SD365R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. LiteSpeed only. SD365R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. Lite- Speed and CLIP mode. H365: Low -profile 135°F fixed thermal sensor. LiteSpeed only. H3654V: Low -profile 135°F fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. H365R: Low -profile, intelligent, rate -of -rise thermal sensor. Lite- Speed only. H365R4V: Low -profile, intelligent, rate -of -rise thermal sensor. Ivory. LiteSpeed and CLIP mode. H365HT: Low -profile intelligent 190'F/88°C fixed thermal sensor. LiteSpeed only. H365HT-IV: Low -profile intelligent 190*F/88'C fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. Legacy Devices CP355: Addressable low -profile ionization smoke detector, SD355: Addressable low -profile photoelectric smoke detector. SD365T: Addressable low -profile photoelectric smoke detector with thermal sensor. SD355R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. SD355CO: Addressable, low -profile device that provides fire, heat, and carbon monoxide (CO) detection. H355: Fast -response, low -profile heat detector. Page 2 of 4 — DF-609573 - 316/2018 H355R: Fast -response, low -profile heat detector with rate -of -rise option. H355HT: Fast -response, low -profile heat detector that activates at 190'F/88'C. AD355: Low -profile, intelligent, 'Adapt" multi -sensor detector 13350LP base included). B200SR: Addressable sounder base. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. D355PL: InnovairFlex low -flow non -relay duct -detector housing; includes SD355R. ONR: InnovairFlex low -flow non -relay duct -detector housing. (Order SD355R/SD365R separately) DNRW: InnovairFlex low -flow non -relay duct -detector housing, with NEMA-4 rating, Watertight. (Order SD355R/SD365R separately.) Add "&&b/e AfadWos MMF-300: Addressable Monitor Module for one zone of normally - open dry -contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end -of -line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) I DC. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option, Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300. Addressable Monitor Module for one zone of conventional two -wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style Y/Z (Class B/ A) zone of supervised polarized Notification Appliances, Mounts directly to a 4.0' (10,16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM13500. BG-12LX: Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions required for Style 6 or 7 operation). ISO.6: Six -fault isolator module, Mount one or two modules in a BB- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet, SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten -input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six -zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six -circuit supervised control module. Mount one or two modules In a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six -relay control module (Form-C relays). Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SWYFT *7#Wo*s Devices W-GATE: LiteSpeed Wireless Gateway W-SD355: LiteSpeed intelligent, wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135') heat detector. W-SD355T: intelligent wireless photo/heat detector, W-H355: LiteSpeed intelligent wireless fixed -temperature (135') heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module, W-CRF: LiteSpeed Intelligent wireless relay module. W-BG12LX: LiteSpeed Intelligent wireless pull station. WAY-RL, WAY-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV bases. W-LISB, Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE. For more information on Compatible Addressable Devices for use with the ES-200X, see the following data shoots (document num- bers): SD365 Series (OF-61010), H365 Series (OF-61011), AD355 (OF- 52386), BG- 12LX (OF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF- 52374), CMFICRF Series (DF-52130), CP355 (DF-52383), H355 Series OF-52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 Series/ MOF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF- 52356), SD355ISD355T (DF-52384), and SLC Wiring Manual (51309). NOTE: Legacy 300 Series detection devices such as the CP300/CP350, SD300(7)ISD350(7) and older modules such as the M300, M301, M302, C304, and 86-100( are not compatible with LiteSpeed polling, If the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. ADDRESSABLE DEVICE ACCESSORIES End -of -Line Resistor Assembly (R-47K and R-3.91K): The 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, and CMF-300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted -pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. 11 11 1 0 1 11,11 DF-60957:8- 3/6/2018— Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits ................................................ I Addressable device capacity ....................... ......... 198 Programmable software zones .................................................99 Annunciators .... ........ ......... .................. _ .... .......... ............ 16 Electrical Specifications AC Power: 120/240 VAC, 50/60 Hz, 3.25 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, super- vised. Battery: Two 12 V 18AH lead -acid batteries. Battery Charger Capacity: 7-18 AH (ES-200X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power -limited, Notification Appliance Circuits: Terminal Block provides connec- tions for four NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power -limited, supervised circuitry, Maximum signaling current per circuit: 2,5 amps special application, 250mA regulated, End -of -Line Resistor: 4.7k ohm, Y2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 ki2 - 22 kQ ELR range. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non -power -limited, non -supervised, Cabinet Specifications Door: 19.26" (48.92 cm,) high x 16.82" (42.73 cm.) wide x 0.72" 1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep, Trim Ring (TR-CE): 22,00" 55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges NFPA Standards The ES-20OX complies with the following NFPA 72 Fire Alarm Sys- tems requirements: LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). REMOTE STATION (Automatic, Manual and Waterflow) Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to LIL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) PROPRIETARY (Automatic, Manual and Waterflow). CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). OT, PSDN (Other Technologies, Packet -switched Data Net- work) IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic ES-20OX control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL, S624 FM approved CSFM: 7165-0075:0500 FDNY: COA #6261 NOTE: See DF-60958 for ULC-listed model. AlarmNeW, Fire-LIts(D Alarms, SWIFTO, and System Sensorg are registered trademarks of Honeywell International Inc. MicrosoftO and Windows(R) are registered trademarks Of the Microsoft Corporation. 02018 by Honeywell International Inc, All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 1192 0 01 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice, IIALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Country of Origin: USA www.firelite.com Page 4 of 4 — DF-60957:B - 3/612018 w FIRE -CITE ES-20OX a Altitude m !, { f 24 BATTERY CALCULATIONS lift Rom inef l T118t2018{ f l q ti$ 4`£ §\•: f 1 Ysq 1 s'y l Y ` y C i { {J. f t"'i '£,' f i'tSi` 4s Xitt'yl ... \ta.\2 X k 4.?£•`fi`2£f, C;`?i XetJ l\.' t i ,;.}'r i, t ?t :l s Q ... f. .: . \:: tY?;•),i, •..Y i. `:`, e f t' e l k:Y W St.,fr ."*•zb FireMain Panel 1st FI IT Closet v\2 i vfX ` Main CTRL Panel Annunciator 0.141 0.015 0.267 Smoke Detector Heat Detector 04003 0.0003 0.0008 0.0003 Addr. Pull Station ef 0.0003; 4 0.001 Duct Smoke Detector Cellular Radio 00710 3 0.2000 lw n:.i' q,, krf `3,i,• i It?}._ ., v ..;{ia, t '.'zlf"\\l'* ..... ,;,, X\f\ 'C t." O,OOOOr z 01 4 \aZ,`; :t 0.0000 O/ a0000 0.0000 0.0000 kf, \ 1, 2 r• ?tS X1£ IZ. f 'S ;: , 4 h TqS tY 0,0000 i ? t xt`, i '•'bk `, J 4 K ,. 3 } } ` z 1 S" Z '' rJ 0.0000 4 0.0000 0.0000 0.0000 0.0000r i $, 04000 0.0000 AA 4X Ys ,r ttY\ y1 b`X vA'ti ti 3 ts. 04WO00 i ti;, OA.00W 010MOOWO t 0.000V1 0.0000 0.0000: hOw0000 0.0000 0.0000. 0.0000 ti.0000 O.00OQ tf ,. O,OOpO x i ,4 t. t2 # it" \"I " , t' '\ s'v, ix.; `i.4 0.0000 fy4} SY0.0000 i. 3Yh:<J ! `t `h\ w £1 11, V.•..4rWVM1t 41 ,; '. s, Notification Appl Circuit 0400 1,208 #14 Saud''' 300 8,9596 Notification Appl Circuit 0.000 1.610 14 Solid 250 9.33% Notification Appi Circuit 0.000 0473 < 14 Solid 290 4.11% Notification A I Circuit 0.000 0.910' 14 Solid 120 z ' ' 2.704E 0.229 4,70 Command shortcuts Configure Circuits Print Page to 1 h -- L-I IProject Information Project Name: Aftftude Project ID: 0 Prepared By: Bill Rornine Date: 7/1812018 cation Appi Circuit IT, 4 System Sensor P2/PC2 Horn/Strobe 77cd) 1 Unused Unused Unused FgggEIIIIIII'My 11"E"I Via', MINE` ME MMMM#: R WA Notification Appl Circuit OMNI 5 System Sensor P2/PC2 Horn/Strobe 77cd) 1 Unused Unused Unused Totalsl 0.000 1 1.510 1 cation Appi Circuit 1 System Sensor P2/PC2 Horn/Strobe Ocd11 2 System Sensor P2/PC2 Horn/Strobe 7 Unused Unused Totals i 0.000 1 0.573 1 f" Project Information Project Name: Altitude Prepared By: Bill Romine 1 1System Sensor• ••- • 1 0!! l 1!! i!i A fit! i Ii1 1 lii 1!! 1 4i! 01 1 1/i i Features: Clean Dead -front Construction 0 Digitally Recorded Automatic Evacuation Message Up to 4 Minutes of Message Capacity) 0,100 Waft High Efficiency Digital Amplifier 0 25 or 70 VRMS Field Selectable 0 120 VAC Power Supply and Battery Charger 0 Live Microphone Override of Message and Tone 9 Analog Addressable Compatible 0 High Reliability, No Maintenance, Fully Supervised Easy Installation and Operation 0 Natural Sound Recordings 0 Built in Alarm and Alert Signals 0 Up to 4 Minute Message Capacity 0 Works with 12VDC or 24VDC Fire Alarm Panels 0 Works with Analog/Addressable and Microprocessor based Fire Alarm Panels. 3 Minute Message Restart on Microphone Key 24 Hour Backup with two 12V 7AHr Batteries 0 Made in the USA. Description: The EVAX 100 operates with any Fire Alarm Control Panel (FACP), and provides 100 Wafts of speaker power. The EVAX 100 includes all necessary features to provide an effective voice evacuation system. With the addition of zone splitters, remote microphone panels, and expander modules, the EVAX 100 can be custom configured to satisfy the needs of most applications. The EVAX 100 has its own power supply and battery charger. Panel must be wired with 120 VAC and standby batteries connected. A digital message repeater (DMR) is built into the EVAX 100. The selection of alarm tone and automatic message repeats, as well as the 6 Hour delay of the AC power failure reporting feature are all field configurable. The paging microphone is an integral component. Removal of the microphone from the panel will cause a "Trouble" condition which will be reported locally, as well as through the FACR The EVAX 100 is housed in an attractive surface or semi -flush mounted backbox, with a hinged and key locked door. EAXSS'FEMS SO [IND v Y SOLUTIONS Voice Evacuation System EVAX 100 shown with Keylocked Door Removed Listings: ULMEA Pending S5661 6911-1446:104 Ordering Information: Description Model Number 10OW Voice Evacuation System, with: EVAX 100 Power Supply / Battery Charger Paging Microphone Digital Message Repeater 10OW Voice Evacuation System, with: EVAX 100/4Z 4 Speaker Zones 10OW Voice Evacuation System, with: EVAX 100/8Z 8 Speaker Zones 10OW Voice Evacuation System, with: EVAX 100/ 1 2Z 12 Speaker Zones, in a Large Cabinet 14.5 x 27 x 4" w*h*d* 10OW Voice Evacuation System, with: EVAX 100/16Z 16 Speaker Zones, in a Large Cabinet 14,5 x 27 x 4" w*h*d* 33 Chestnut Street New Haven, CT 06511 203-752-1806 FAX 752-1906 WWW.EVAX.COM Products: Zone Splitters - EVX-4Z / EVX-2ZA 0 Remote Microphone - EVX-RM - EVX-SC Zone Splitters: Features: 4 Class B Supervised Audio Outputs EVX-4Z 2 Class A Supervised Audio Outputs EVX-2ZA Individual Zone Switches All Call Switch Automatic General Alarm Zones Selectable when Alarm is Silenced Optional Alarm by Zone Individual Zone LEDs Indicate Zone Selection. Individual Zone LEDs indicate Zone Trouble. Up to 8 Zones Mounted in EVAX 25/501100 Up to 16 Zones Mounted in EVAX 1501200 UL Listed. Made in USA The EVX-4Z or EVX-2ZA Zone Splitters allow the output of any Evax Systems audio amplifier to supervise and drive multiple zones. Individual zone select switches are provided which allow the manual selection of any or all voice evacuation zones for emergency paging. Automatic zone selection may be provided by the zone splitters by the connection of normally -open contacts from the Fire Alarm Control Panel (FACP) or other auxiliary control system. An "ALL -CALL" Switch is provided which will select all voice evacuation zones for emergency paging. Individual LEDs are provided to annunciate zone status of either "Zone Active" or "Zone Fault". All EVX-Series Zone Splitters are compatible with 25V and 70V voice evacuation system amplifier outputs. FVAXSYSTEMS SOUIVIO SOLUTIONS EVX-4Z Four Zone Splitter Listings: Voice Evacuation EVX-RM Shown with key locked door removed. UL MEA* MEA & CSFM Pending on EVX-RM S5661 6912-1446:101 Ordering Information: Description Model Number Zone Splitter EVX-4Z Four Zone, Class B Operation Zone Splitter EVX-2ZA Two Zone, Class A Operation Remote Paging Microphone Panel EVX-RM Remote Paging Microphone Supervisory Card EVX-SC 33 Chestnut Street New Haven, CT 06511 203-752-1806 FAX 752-1906 WWW.EVAX.COM Remote Microphone Panel: Features: All-Call Remote Microphone Overrides alarm tone and automatic message Any number of remote microphones Dead Front Cover Construction. Paging Microphone with Press to Talk Button. In4Jse" and "Fault" LED. Supervised Wiring. May be located up to 5000 feet away from Voice Evac Panel. The EVX-RM is a supervised remote microphone for use with the EVAX 25/50/100 voice evacuation system. The microphone provides crystal-clear live voice messages over the system speakers. Ideal for use when the fire alarm panels are in an electrical room, and the annunciator and microphone are in the lobby. The EVX-RM is perfectly suited for applications in gymnasiums, nightclubs, auditoriums, control rooms, churches, guard stations, and other places of assembly. Up to 5 EVX-RM Panels may be connected to a single EVX-SC Supervisory Card. This provides supervision of the wires to the EVX-RM and they may be located up to 5000 feet away. Housed in an attractive surface or semi -flush mounted backbox, with a hinged locking door. The EVX-RM features dead front construction, a microphone with a Press -to -Talk" button, and discreet LEDs to display In -Use" and "Fault" status. Backbox Dim: 8 x 10 x 3" w-h-d Color: Charcoal Grey-std Red -optional Typical Application of EVX-4Z Zone Splitter Operation: In the normal (Standby) mode, announcements can be made from any remote microphone at any time. Simply keying any remote microphone will allow a manual paging message to be broadcast in an "ALL -CALL" mode. If multiple remote microphones are used, and two or more are simultaneously keyed, then the first microphone keyed will have paging priority. The paging microphone in the master will always have priority over any and all remote microphones. The EVX-RM can be wired for general public address, and will be automatically disabled on alarm. In the alarm mode, the keying of any remote microphone will interrupt any pre-recorded tone or message, and will allow manual voice evacuation messages to take priority. When the microphone Press -to -Talk key is released, the automatic pre-recorded voice evacuation message typically tone and voice) will be replayed from the start. Typical Application of Remote Microphone EVX-SC 0 In Use Supervisory 0 Fault 0 Card o 0=-, 7 EVX-RM 1101 ANNON Moma I < 5000 feet ___ EVAX 25/50/100 Remote Microphone Fire Alarm Strobe Circuit W1 Z 3 4 1 6 7 4 00000000 TM al Class "B" 0 T82 01 0 00 Voice ESpeaker Circuit vac0 3. 0 0 0 0 EVX-4Z 00 G Fire Alarm Strobe Circuit 0 EVX_2ZA G 00 Class "A" Voice Evac Speaker Circuit 00 ira; ! tom T83 O( Do o..0 F Block Diagram SimplifiedVAXSYSTEMS Specifications are subject to change without notice. Specifications are provided for Information only and no responsibility Is assumed SOUND SOLUTIONS 1 E EVXA0598R1 by Evex Systems, !LC for their use. 11111- Typical Installation: Supervised - Power Limited Fire NA C (Yo tion AajLlianc AlarmI IControl Sgeervised - Power Limited Panel NAC . I 120 VAC Transformer" er* Power Transformer is built into the EVAX 100, TKI I Strobe Circuit UN Voice Evacuation Speaker Circuit Supervised - Power Limited 69 Fl EOLR 0 Troueb 0 0 System $taws LEN 1101 Anwwl INNNIN 1 12 V - COD 12 V B — Battery +0 1 LBattery +C3 Technical Characteristics: Primary Power: 120VAC @ 2A 24 VDC Battery Power: 0.180A Standby 2. 5A Alarm Output: 100 Watts @ 25/70 VRMS Tone and Voice Backbox Dim: 14.5 x 18 x 4" w-h-d Color: Charcoal Grey-std Red -optional Engineers Specifications: The voice evacuation system shall be Evax Systems Series EVAX 100 or approved equal. The voice evacuation system shall provide 100 watts signal power and 100 watts voice power, and shall be UL listed. All speaker circuits shall be field selectable for 25 or 70 Vrms operation and shall be power limited. The voice evacuation system shall be micro -processor based, and shall contain an integral microphone, E VikxSYSTEMSM SOUND SOLUTrONS Class " A Speaker Circuit if required Standard Message - 15 Seconds: Attention Please, there has been a report of an emergency. Proceed calmly to the nearest exit and leave the building immediately. Do not use the elevators, use stairwells where necessary. All handicapped occupants shall use the building evacuation plan." Specifications ( continued) 100 Watt audio amplifier, tone generator, digital message repeater, 120VAC power supply and battery charger. The voice evacuation message/signal shall be broadcast until the Fire Alarm Control Panel (FACP) is reset, or until fire emergency personnel interrupt the broadcast with a manual page. On reset system shall automatically return to standby (normal operating) condition. A secondary message shall be provided which can be triggered by the closure of a contact from either the FACP or from any normally open contact device. Remote paging microphone(s) will be supported by the system through a supervised circuit. Remote microphone( s) may be mounted up to 5000 feet away from the voice evacuation panel. Specifications are subject to change without notice. Specifications are provided for Information only and no responsibility is assumed by Evax Systems, LLC for their use. Evax 100/4 Battery Calculation Worksheet Project Name: Altitude Trampoline, 1810 Rinehart Road Church Date: 7/18/2018 Prepared by: Bill Romine STANDBY CURENT CALCULATIONS 1. The Standby Current for the Evax 100 2. Multiply by the number of hours required (_24) TOTAL STANDBY CURRENT IN AMP HOURS ALARM CURRENT CALCULATIONS 1. List the speaker wattage requirement (150 max) 2. Multiply the Speaker Wattage by 0.040 for Alarm Current 3. Multiply Step 2 by 0.25 (15 minutes of alarm) TOTAL ALARM CURRENT IN AMP HOURS BACKUP BATTERY REQUIREMENTS 1. Enter Standby Current 2. Enter Alarm Current 3. Add Steps 1 and 2 together for TOTAL BACKUP BATTERY REQUIREMENT 18 Amps X 24 Hrs. 4.32 AH 100 Wafts 4 Amps 1.0 AH 4.32 AH 1.0 AH 5.32 AH BATTERY SIZE USED 7 AH Universal full event sole path cellular & dual path cellular WorUP commercial fire alarm reportingVrom any panel brand, virtually anywhere For use as primary or backup communications on all 12V-24V control panels and FACPs that communicate using Contact ID and 4/2 (such as on legacy panels) Reports to any Central Station nationwide, via dial upor|P Communicate critical life and safety alarm multibillion -dollar cellular nationwide reliable networks, VerizonNetwork Certified or/gl&T,for maximum security & liability protection Easy, flexible Installation, activation & online account management Cost - saving models and plans for any code requirement. Substantial savings over monthly dedicated landline charges. And, $ 100 saving incentive for system upgrades from old radios ( all makes) and old POTs landlines, as well as new installations UL and SuarLinkSeries Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal support for any brand 1ZV to24Vfire alarm control panel, reporting inContact |Dand 4/2. With broadest coverage footprint available inVeMzunNetwork CertU5ed=[DK4AurGSM 3/4Gmodels nnthe AT&T network, aswell asmercantile models, all provide the most economical solution and for easy, versatile installation. Safeguard Accounts & Reliability. For applications currently relying upon quickly - disappearing traditional phoneUnes, StarLinkwireless communicators can beused for primary orbackup communications, and will not only safeguard the fire alarm reporting transmissions for the future, but provide h dmonthly savings for h costly FACP-dedicated landline they replace. And, for upgrading older wireless fire alarm communicators on 2G and other phased -out cellular networks, all Starl- ink Fire radios, offer a $100 tradeup incentive to help defray the cost of the hardware replacement to the advanced state-of-the-art Starl-ink model of choice. Flexible Performance & Reporting Options. StarUnkF|ve provides full data reporting, |nsole and dual path, asaprimary u/backup, toany central station ofyour choice, without requiring any special equipment onpremises. Ultra -affordable plans are available 0omeet various codes and requirements, with supervisory check -ins from 2O0seconds, 0o5- minutes' toanhour. The units are very easily activated, plans and options are selected, and 24/7account management is provided all through vm^wvoapcncomneLcom.And, StarLink Fire Communicators are easily connected toany panel u, Fire Alarm Control Panel (FA[P)gandandlyoperating between 12V and 24V. Flexible inany application, StarLinkFire also comes instandard, orMercantile Models inmetal housings, with code -compliant supervision, with orwithout using conduit; and choice of power options, powered bythe panel orusing its own 1ZOVPower khiSupply. cVondard mmo( unmmetxmooek mmmtt, re" pe( wriy) W1 Napco St:mrU in& r Universal Fire Alarm Communicators Sole Path Cellular and Dual Path CellularWor|PModels ^ Bonus: Full High-Speedpco Panel remote Volko uploading/ downlo ading wen°npn ^ Choice of plans (varies bymodel) ' check - ins from 2OO — Cennneo seconds, t^S-minutesto1hour, VehzonorAT&T , COMPLIANCES: NFP/J2Editions: 2016'2013. 2010'2007; V 86 9chEd UUG1UV 98SU 1O23' NYTFD[SFx4 Patented l amplification circuit and '' ' ' ' h performance antenna for longer range and reliability nationwide N p hN w mm k 0 m w vN m FIRM , Money -saving Trademphm« emtive credit MMMERCIAL t«"v v«v~^ Fire ~pec^fica^v*""vs u Information STANDARD MODELS: . COMMERCIAL FINE SOLE PATH CELLULAR & Durable ABS plastic housing includes three DUAL PATH CELLULAR &/ORVP('I"NODELS):* mounting (for commercial application, aligns with triple gang 5LE-CQK8A`F|REStandard ABS (Red)Fire Sole Path Alarm boxes.) Communicator, Cellular CDMA, Verizon-Network Certified Dimensions: 5'3/8"x7-7/8!x1-7Y8!'0HxVVxD> Weight: 13.5uz LED Indicators -Green Signal Strength; Amber- Busy/ Activation; Red -Trouble Patented Signal 800st"'signal amplification circuit and high - gain perfonnanoeantenna Operating Environment, Oro49"[82'12U°R.upno939h humidity ( non -condensing) 1ZV- 24VUniversal FA[PSupport, auto -current sensing. Support all brands communicating inContact |Dand 4/2 Powered byPanel, Low current draw, 71mAstandby, 2O0mA transmit MERCANTILE MODELS (similar wwabove, with): Locking Metal Enclosure with Hinged door & 2key- slots for wall mounting (LED indicators, inside). Dimensions: 9-5/ 8"x11-3/4!'x3- 3/8^D(HxVVxD) Weight: 8lbe(max,power supply models) Electrical Ratings for 12[NA[60Hz For Models with Power Supply: Input Voltage: 120VA[ Nomina| Input Current: 4OOm4maximum Maximum Charging Current: 200mA Electrical Ratings for +12V For Models without Power Supphc 11'15VDC¢mvwr- limitedoutput from listed control panel) Input Current: 71mAwith peak RF transmissioncurrent of Electrical Ratings for the HN1Burg/Fire Input. Input Voltage: 915VD[ Maximum Input Current: Uptn2mAfrom FACP NACdnoit Electrical Ratings for IN 2 and IN 3: Maximum Loop Voltage: 16VDC Maximum Loop Current: 12mA Electrical Ratings for 3 PGM Outputs: Open Collector Maximum voltage 3V when active; 15V maximum when not active Maximum PGM Sink Current: 50mA mount. Operating Environment 0 to 490[(32-1200F),upto 93% humidity ( non -condensing) 1ZV'24YUniversal FACPSupport, auto -current Support all brands communicating in Contact ID and 4/2. as above, Dual Path Alarm Cellular &/or|P(primary orbackup, selectable) SLECDKAA'[ FG-PSCommercial Fire Mercantile model inred metal housing, [DK4A_Verizon-NetworkCertified. Direct 12OVA[Powered (w/provisions for backup battpry/cha ). Or, Optional TRF12plug-in transformer may beused, where codes permit SLE[DyWA-CFB[ommerda| Fire Mercantile model inred meta} housing on[DKAA'Verizon'NetworkCertified Powered directly from control panel Note: Substitute prefiv"SLa314sunany models above for AT&T 314G Network ACCESSORIES: SLE-DLEXrOptional, asabovefnrdown| oading,emendsd|sance toNapcopanel upto10Y TRF12 Optional ,lug inA[Transformer, 16. 5V/2OVA(use is subject tolocal code compliance) SLE-DLCBL Optional High - Speed NapcuPanel Up/ download cable k r Fim m *`~=~ " COMMERCIAL FIRE CELLULAR &|P 333 Bayview Ave,, Amityville, NY 11701 USA COMpNAwCES.wppxr2 Edmunczo16,zo13,20n0,2mn; uLo*49th Ed.,uL1a10,uu985 uu023mvCFD; cspM StarLink Fire are also rated msupport Intrusion/Burglary alarm reports ~^* oowm"able,a",u"v~mmogn^/000*"re*ademo*smw^PCo. Pats, Pending. Specifications mmeom**nge. ONAPCO, NAPCO Sec.dryTechnologies*^'wwDAw.*m, ^676c2017.1 m,and ""nzo"Network Certified, oL.AT&T and other trademarks, are trademarks ", their moveai. mmn== and are unaffiliated with m^mo, 11,111 KNE DF-52013: D • E- 100 BG-1 2LX Addressable Manual Pull Station The Fire•Lite BG-12LX is a state-of-the-art, dual -action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire -ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-1/0) or semi - flush mounted. Semi -flush mount to a standard single - gang, double -gang, or 4' (10.16 cm) square electrical box. Smooth dual -action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable pollycarbonate material with a textured finish, Specifications Shipping Weight: 9.6 oz. (272,15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range. 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use Indoors In a dry location Installation The BG- 1 2LX will mount semi -flush into a single -gang, double - gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-1/0 surface back - box. If the BG-12LX is being semi -flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is tlttwi usually needed for semi -flush mounting with 4" (10.16 cm) or double -gang boxes (not with single -gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings 1 - 159 with Breakaway Tab removed for MS-9600 Series, 1 - 99 and MS-9200UDLS, 1 - 50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non -coded, with a key - operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red -colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches 2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-1 0 or SB-1/0; or semi -flush mounting on a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box, and shall be installed DF-52013:D • 4/1312012 — Page 1 of 2 within the limits defined by the Americans with Disabilities Act ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops, The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual -action addressable pull station. Includes key locking feature. (Listed for Canadian and non -Canadian appli- cations.) SB-110: Surface backbox; metal. SB-1/0: Surface backbox; plastic. BG12TR. Optional trim ring. 17003: Keys, set of two, Agency Listings and Approval* In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. ULIULC Listed: S711 (listed for Canadian and non -Cana - than applications), MEA: 67-02-E. CSFM: 7150-0075:0184. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. FireLiteO AlarmsO is a registered trademark of Honeywell International Inc. Q2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 1192901 We try to keep our product information up-to-date and accurate. 3M We cannot cover all specific applications or anftipate all requirements. 111111115111111-11MN11NK11Mfi All specifications are subject to change without notice. INALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 6W4105. www.firelite.com Page 2 of 2 — DF-52013:1) - 4/13/2012 DF-52385:D - E-710 H355(A) Series Intellinent Addressable Fire-LITeALEIrMS Thermal Detectors by Honeywell General The Fire*Llte Alarms H355(A) Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors provide open - area protection and are intended for use with FireeLlte's addressable Fire Alarm Control Panels (FACPs). The H355(A) and H355R(A) sensors provide fixed tempera- ture alarm detection at 135°F (571C). The H355R(A) sensor also responds to rate -of -rise conditions of greater than 15°F 8.3°C) per minute. The H355HT(A) is a fixed high -tempera- ture detector that activates at 190°F (881C). These thermal detectors provide addressable property protection in a variety of applications. Two LEDs on each sensor light to provide a local, visible sen- sor indication. Remote LED annunciator capability is available using an optional accessory, the RA100Z. Features SLC loop: Two -wire SLC loop connection, Unit uses base for wiring, Addressing: Addressable by device. Rotary, decimal addressing: 01 — 159 with MS-9600 series, 01 — 99 with MS-9200 series, Architecture: Sleek, low -profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device -type identifica- tion. Built-in tamper resistant feature. Built-in functional test switch activated by external magnet. Operation: Factory preset at 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate -of -rise triggers at 15°F (8.3°C) per minute for the H355R(A). 360'-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink red in Normal condition and turn on steady red in Alarm. Visible LEDs "blink" every time the unit is addressed. Mechanicals: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct -surface or electrical -box mounting. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelectric, ioniza- tion and thermal sensors. Other system features: Remote test feature from the panel. Walk test with address display. Low standby current. H355(A) in B21OLP(A) Base 94-5V plastic flammability rating. Options: Remote LED output connection to optional RA10OZ remote LED annunciator. Flanged surface mounting kit, Installation H355(A) Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5* (3.81 cm) deep. For a chart of compatible junction boxes, see OF-60059, NOTE: Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class "B") wiring only. Applications Use thermal detectors for protection of prop". Construction These detectors are constructed of off-white fire-resistant plastic. The H355(A) Series plug-in intelligent thermal detec- tors are designed to commercial standards and offer an attrac- tive appearance. Operation Each H355(A) Series detector uses one of 159 (MS-9600 series) or 99 (MS-9200 series) possible addresses on a con- trol panel SLC loop. It responds to regular polls from the con- trol panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimu- lates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The H355(A) Series offers features and performance that represent the latest in thermal detector technology. DF-52385:1) - 5/17/2013 — Page 1 of 2 Spefications Size: 2.1 " (5.3 cm) high; base determines diameter. B21 OLP(A): 6.1 " (15.5 cm) diameter. 8501 (A): 4. 11" (110.4 cm) diameter. 8200SR(A): 6.875" (117.46 cm) diameter, 8224RB(A). 6.2" (115.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Installation temperature: H355(A), H355R(A): —4°F to 1 OOoF (-20°C to 38-C). H355HT(A): —4°F to 150°F (-20°C to WC). Humidity range: 10% to 93% relative humidity (noncon- densing). Voltage range: 15 to 32 VDC peak. Standby current: 300 pA 0 24 VDC (one communication every five seconds with LED blink enabled). LED current: 6.5 mA 0 24 VDC. Mounting: B210LP(A) flanged base, included. See 'Product Line Information: Intelligent Bases" if using a different base, Fixed -temperature setpoint: 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate -of -rise detection: responds to greater than 15°F (8.3°C) per minute. Listings and Approvals Listings and approvals below apply to the H355(A) Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2517. ULC Listed (models H355A, H355RA, H355HTA) CSFM approved: 7270-0075:0195. FM approved. INTELLIGENT BASES NOTE. "A"suffix indicates ULC Listed model. NOTE. The detectors plug-in base can be changed off for special applications. For details about intelligent bases and their mount- ing, see OF-60059. B210LP(A): Plug-in detector base (included); standard U.S. flanged low -profile mounting base. 821 OLPBP: Bulk pack of B21 OLP; package contains 10. B501(A)- Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 MM2). Relay type: Form-C. Rating: 2.0 A 0 30 VDC resistive; 0.3 A 0 110 VDC inductive; 1.0 A 0 30 VDC inductive. B22481(A): Plug-in System Sensor Isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). ACCESSORIES F110: Retrofit flange to convert B210LP(A) to match the B350LP(A) profile, or to convert older high -profile bases to low -profile. F110EIP: Bulk pack of F1 10; package contains 15, F21 0: Replacement flange for B21 OLP(A) base. RA100Z(A): Remote LED annunciator, 3 — 32 VDC, Mounts to a U.S. single -gang electrical box. For use with B501(A) and B210LP(A) bases only. SMS600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XF12B. Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. Product Line Information XP-4: Extension pole for XP2B. Comes in three 5-foot (1.524 NOTE. A" suffix indicates ULC Listed model. in) sections. H355: Intelligent thermal sensor; 135° F (57° C); B21OLP base T55-127-010: Detector removal tool without pole. included. H355A: Same as H355 but with ULC Listing; B21OLPA base included. H355R: Same as H355 with rate -of -rise feature; B21 OLP base included. H355RA: Same as H355R but with ULC Listing; B21OLPA base included. H355HT: Intelligent fixed high -temperature thermal detector; 190° F (88° C); B21OLP base included. H355HTA: Same as H355HT but with ULC Listing; B21OLPA base included. Fire-Lite(F) Alarms is a registered trademark of Honeywell International Inc, 02013 by Honeywell International Inc, All rights reserved, Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 1 09001 We try to keep our product information up-to-date and accurate, SEE We cannot cover all specific applications or anticipate all requirements. go*= a mNmgqm All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105, www.firelite.com Page 2 of 2 — DF-52385:D - 5/17/2013 DF-52384:1) • E-160 SD355(A) Series Addressable Photoelectric rwi=_ 411-12 Smoke Detectors by Honeywell General The SD355(A), SD355T(A), and SD355R(A) addressable, low -profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite's Addressable Fire Alarm Control Panels (FACPs). The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (570C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indica- tion. Remote LED annunciator capability is available as an optional accessary, PN RA100Z(A). The SD35SR(A) is a remote test capable detector for use with D355PL(A) or DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP Two -wire loop connection. Unit uses base for wiring. ADDRESSING Addressable by device. Rotary, decimal addressing: 01 — 99 with MS-9200UD(LS), and 01 —159 with MS-96000D(LS). ARCHITECTURE Unique single -source, dual -chamber design to respond quickly and dependably to a broad range of fires. Sleek, low -profile design. Integral communications and built-in type identification. Built-in tamper -resistant feature. Removable cover and insect -resistant screen for simple field cleaning. OPERATION Withstands air velocities up to 4,000 feet -per -minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. MECHANICALS Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single -gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box using a plaster ring — included). OTHER SYSTEM FEATURES Fully coated circuit boards and superior RF/transient pro- tection. 94-VO plastic flammability rating. Low standby current. r SD355(A) in B21OLP(A) Base OPTIONS Remote LED output connection, PN RA100Z(A). Applications Use photoelectric detectors in life -safety applications to pro- vide a broad range of fire -sensing capability, especially where smoldering fires are anticipated. ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white fire resistant plas- tic. SD355(A) series plug-in, low -profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation SD355(A) series plug-in detectors use a detachable mounting base to simplity installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE. Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class B) wiring. SD355R(A) mounts in a 0355PL(A) or DNR(A)/DNRW duct detector housing. Operation Each SD355(A) series detector uses one of 99 possible addresses on the MS-9200UD(LS) and up to 318 (159 on each loop) on the MS-9600UD(LS) Signaling Line Circuit SLC). It responds to regular polls from the system and reports its type and status. The addressable photoelectric sensor in the SD355(A) series has a unique unipolar chamber that responds quickly and uni- formly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet -per -minute (20 m/sec.) without sending an alarm level signal. Because of its unipolar cham- ber, the SD355(A) series is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DF-52384:D • 2/11 /2015 — Page 1 of 2 Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on inspection, Testing and Maintenance) when installed/connected to a MS-9200UD(LS) or MS- 960OUD(LS) addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS-9200UD(LS) or MS-9600UD(LS) for record keeping. Specification Voltage range: 15 - 32 VDC (peak). Standby current: 300 pA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft./min. (20 m/sec.) maximum. Size: 2.1" (5.33 cm) high; base determines diameter. 8210LP(A): 6.1" (15.5 cm) diameter. B501 (A): 4.1" (10.4 cm) diameter, 6200SR(A): 6.875" (17.46 cm) diameter. B224RB(A): 6.2" (15.748 cm) diameter. Weight: 3.6 oz. (102 g). Operating temperature range: for SD355(A): 0°C to 490C 32°F to 120°F); for SD355T(A): O°C to 380C (32°F to 100°F). SD355R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Temperature: O°C - 49°C (32°F - 1201F). Relative humidity: 10% - 93%, non -condensing. Listings Listings and approvals below apply to the SD355(A), SD355T(A), and SD355RT(A) detectors. in some cases, cer- tain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: 51059. ULC Listed: 51059. CSFM:7272-0075:0194. MEA:243-02-E. FM approved. Product Line Information NOTE: A"suffix indicates ULC Listed model. SD355: Addressable photoelectric detector; B21OLP base included. SD355A: Sames as SD355 with ULC Listing; B210LPA base included. SD355T: Same as SD355 but with thermal element; B210LP base included. SD355TA: Same as SD355T with ULC Listing; B21 OLPA base included. SD355RA: Same as SD355R with ULC Listing for use with a D355PLA or DNRA duct detector housing; B210LPA base included. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: The detector's plug-in base can be changed off for special applications. For details about intelligent bases and their mount- , ing, see OF-60059. B210LP(A): Plug-in detector base (included); standard U.S. flanged low -profile mounting base. 8210LPBP: Bulk pack of B21 OLP; package contains 10. B501 (A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSi Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mmz). Relay type: Farm-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A 30 VDC inductive. B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see OF-52389). ACCESSORIES F110: Retrofit flange to convert B210LP(A) to match the B350LP(A) profile, or to convert older high -profile bases to low -profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B21 OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR2B. Comes in three 5-foot 1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with SD355(A) only; box of 10. WCK-200B: White detector covers for use with SD355(A) only; box of 10. SD355R: Remote test capable addressable photoelectric Firel.tteO Alarms is a registered trademark of Honeywell International Inc. detector for use with a D355PL(A) or DNRA/DNRW duct 02015 by Honeywell International Inc. All rights reserved, Unauthorized use detector housing; B21 OLP base included. of this document is strictly prohibited. This document is not intended to be used for installation purposes. IO 9001 We try to keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. NON$ i MNNWn= All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www,firelite.com Page 2 of 2 - DF-52384:D • 2/11/2015 DF-52121:E - E-325 MMF-300(A) Series, MDF-300 Addressable Monitor Modules Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry -contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two -wire smoke detectors MMF-302(A)). MMF-300(A) is a standard -sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D Class A) or Style B (Class B) circuit of dry -contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that super- vises a Style B (Class 8) circuit of dry -contact input devices. Its compact design allows the MMF-301 (A) to be mounted in a single -gang box behind the device it monitors. MMF-302(A) is a standard -sized module used to monitor and supervise compatible two -wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard -sized dual monitor module used to monitor and supervise two independent two -wire Style B Class B) dry -contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two -wire sys- tems. LiteSpeed T11 is a communication protocol developed by Fire-Lite Engineering that greatly increases the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. MMF.300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two -wire SLC loop. No additional power required. High noise (EMF/RFI) immunity, EMS screws with clamping plates for ease of wiring. Direct -dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two -wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two -wire or four -wire fault -tolerant Initiating Device Circuit (IDC) for normally -open -contact fire alarm and supervisory devices. The module has a panel -controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) AppucAmNs Use to monitor a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally - open dry -contact alarm activation devices. May also be used to monitor normally -open supervisory devices with special rn J7 90 IT—= MMF-300(A) (Type H) supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or We D (Class A) Initiating Device Circuit. A 47K Ohm End -of -Line Resistor provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERA 77oN Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal(short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel, The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SpEcwfcAnoms Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32*F to 120'F (0°C to 49'C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301 (A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two -wire SLC loop. No additional power required. High noise (EMFIRFI) immunity. DF-52121:E - 0713012015 — Page 1 of 4 Tinned, stripped leads for ease of wiring. Direct -dial entry of address: 01 — 159 on MS-9600 series panels, 01 — 99 on other compatible systems 1415 0 1 -ADDRESS 0 1 12 \31 111 4 LOOP 9 8 ,, 7 -6 9 TENS ONES 0 uJ Q Lu cc 01 The MMF-301(A) Mini Monitor Module can be installed in a single -gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two -wire systems where the individual address of each module is selected using rotary switches. It provides a two -wire initiat- ing device circuit for normally -open -contact fire alarm devices. The MMF-301 (A) can be used to replace M301 (A) modules in existing systems. A#A#F-301(A) APPLicATIoNs Use to monitor a single device or a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally -open dry -contact devices. May also be used to monitor normally -open supervisory devices with special supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End -of -Line Resistor (provided) terminates the circuit, MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop, It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC), MMF-301(A) SpEaRcAmNs Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts, Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49'C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1,651 cm) deep. Wire length: 6" (15.24 cm) minimum, MMIF-302(A) Interface Module Supports compatible two -wire smoke detectors, Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring, Direct -dial entry entry of address: 01 — 159 on MS-9600 series panels, 01 — 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel, The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two - wire conventional smoke detectors. It transmits the status normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two -wire detectors being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) Appuwms Use the MMF-302(A) to monitor a zone of two -wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End -of -Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SpEcwti:AmNs Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, I communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and T11): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49'C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2125" (5.398 cm) deep box. MDF.300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two -wire systems. It provides two independent two - wire Initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel - controlled LED. Page 2 of 4 -- DF-52121:E - 07130/2015 40P - -ft NOTE. The MDF-300(A) provides two Style B (Class 8) 10C cir- cuits ONLY We D (Class A) IDC circuits are NOT supported in any application. AfDF-300(A) SpEcwtcAwNs Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on), Average operating current: 750 NA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32* to 120°F (0' to 49*C). Humidity range, 10% to 93% (non -condensing). Dimensions: 4,5" (11.43 cm) high x 4" (10.16 cm) wide x 1,25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) AuTowm ADDRESsiNG The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address '26", then it will automati- cally assign itself to addresses "26" and "27". NOTE. "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface -mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power -limited wiring only. The MMF-301 (A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424. ULC: S2424, FM Approved. CSFM: 7300-0075:0185. MEA: 72-01-E. Product Line Information NOTE: 'A" suffix indicates ULC-listed model. MMF-300(A). Monitor module. MMF-301 (A): Monitor module, miniature. MMF-302(A): Monitor module, two -wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface -mount backbox. NOTE. See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects'/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF-5212 1: E - 07/30/2015 — Page 3 of 4 Fire-Lite® is a registered trademark and UteSpeed "I and FireWatch'" are trademarks of Honeywell International Inc. 02015 by Honeywell International Inc. All rights reserved, Unauthorized use of this document is strictly prohibited, This document is not intended to be used for installation purposes. Ian 9001 We try to keep our product information up-to-date and accurate. Ian, We cannot cover all specific applications or anticipate all requirements. ustims a WMWW* All specifications are subject to change without notice. INALITY SYSTEMS For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of — DF-52121:E • 07/3012015 CITY OF Ski!40RD JUL 11 PERMIT APPLICATION BUILDING DIVISION Application Documented Construction Value: $ 0, $ S-0 0 job Address: ATA zt &4,— t<- 1-0 Parcel ID: Historic District: YesE] Noo— Residential E] Commercial'a Type of Work: NewE] Addition _V_A1 AlterationEl RepairEl Demo 0 Change of UseEl MoveEl Description of Work: t"'. 7,9 Plan Review Contact Person: Phone: Fax: Email: Property Owner Information Name Phone: Street: Resident of property? City, State Zip: Contractor Information Name /17# C_k_ ' Pz_41)'416;_ Street: 5_30 5 . 1cww4v F-A6,*- City, State Zip: Name: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: 0' 7 - 3 3 / — / 61 `Z`1 State License No.: Architect/ Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. Revised: June, 2018 Permit Application FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6`s Edition (2017) Florida Building Code NOTI :: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that maybe found in the pubhF records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. f Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Signature of Contractor/Agerit Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Agent's Name xiaic Fr„u Diary a it: • fate of Florid Commission M GG 060623 My Comm. Expires Jan 16. 2018 C"oror/Agenf is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: June, 2018 Permit Application Ab 4 IV N-W- CONSTRUCTION & DEVELOPMENT" General Contractor SUBCONTRACT AGREEMENT Date: 07/10/2018 This agreement is between Contractor: Project Name: Altitude Trampoline Park Project Address: 1810 Rinehart Road Philco Construction and Develpment, LLC. Sanford, FL 32771 114 N Park Ave. Sanford, FL 32771 Contract Amount: $20,500.00 and Subcontractor: Mack Plumbing Systems, Inc. 530 S Ronald Reagan Blvd 100 Longwood, FL 32750 Article I- Scope of Work For the sum set forth above, the above named subcontractor agrees to install and perform all work outlined in Attachment "A" in compliance with the project plans and specifications, and to furnish all cleanup related to its work. Subcontractor agrees to perform the work in a complete and professional manner, to meet or exceed industry standards for all work performed, and to perform the work in accordance with the contractors schedule. Subcontractor further agrees to notify the contractor of any long lead-time item, which may have an effect on the completion schedule of the project. In addition, be advised that purchase and/or procurement of materials prior to submitted approval are at the subcontractor's own risk. Article H- Contract Payment The Contractor, Philco Construction & Development, LLC., agrees to pay the Subcontractor progress payments for satisfactory completion of Subcontractor's work. 114 N. Park .Ave Sanford, FL 32771 Phone 407-647-7445 State License # CBC 1260967 Progress payments, less retainage of 10%, shall be made to the Subcontractor for work satisfactorily performed. Subcontractor shall submit a progress billing to the Project Manager by the 201 of the month, for the work completed projected thru the last day of the month. Payment to be made Ten 10) days after receipt of payment from the owner. Final payment to be made Ten (10) days after receipt of final payment from the Owner. Article III -Insurance Subcontractor agrees to have in force and effect from the date of the contract, and to its completion, insurance coverage's at least to the following minimums; A. Worker compensation and employers liability insurance. Such policy to include where applicable, provisions for benefits under the United State's Longshoreman's and Harbors work act. B. Commercial automobile liability insurance covering all owned, non -owned, and hired automobiles subject to a minimum combined single limit of $1,000,000 for bodily injury and property damage liability. C. Comprehensive general liability insurance subject to minimum limits as follows: General Aggregate: $2,000,000 Completed operations aggregate: 2,000,000 Personal/averting injury: 1,000,000 Each Occurrence 1,000,000 Inclusive: products and completed operations, personal injury, broad form property damage, and contractual liability (recognizing the provisions of #5 below). D. For the purposes of this contract: Philco Construction & Develpment, LLC. is to be added to the subcontractor's policies as an additional insured; The subcontractor waives their insurer's right of subrogation against Philco Construction & Development, LLC. Subcontractor's insurance shall be primary and non-contributory. Article IV -Guarantee and Warranty Subcontractor agrees to guarantee and warranty his workmanship for not less than one year from the date of final acceptance of this project. 114 N. Park Ave. Sanford FL 32771 Phone 407-647-7445 State License #CBC 1260967 Article V-Flow Down Provision Subcontractor shall assume toward the contractor, all obligations and responsibilities, which the contractor assumes toward the owner. Subcontractor is bound to the owner, including without limitation, any guarantees and warranties. Subcontractors agree to bind all lower tier subcontractors and suppliers to the same terms and conditions as the subcontractor assumes to the contractor and owner. It is the responsibility of the subcontractor to obtain and be familiar with all contract documents, plans, and specifications, which govern or affect the work relationship between the owner and contractor. Article VI -Indemnification To the fullest extent permitted by law, the subcontractor shall indemnify and hold harmless Philco Construction & Develpment, LLC., its employees and assigns from and against all claims, damages, losses and expenses, including but not limited to attorney's fees arising out of the performance of or disputes arising out of this contract, provided that any such claim, damage, loss, or expense is 1) attributable to bodily injury, sickness, disease, death, or injury to, or destruction of tangible property, other than the work itself.); 2) Is caused in whole or in part by any negligent act or omission of the subcontractor and/or it's assigns. Article VII-Breach and Termination Should the subcontractor at any time breach any of its obligations under this agreement or any of the contract documents, plans or specifications, the contractor may issue a written notice of default. Within forty-eight hours of receipt of said notice, if the subcontractor has not taken action to correct deficiencies, the contractor may terminate the subcontract and complete the subcontractors work, either with its own forces or engage a new subcontractor to complete the work. Contractor may withhold payment and deduct the cost of completing the subcontractors work from any amounts due the subcontractor, and if the costs to the cost of completing the subcontractors work from any amounts due the subcontractor, and if the costs to complete said work exceeds the amounts due under the contract, seek compensatory damages against the subcontractor. Failure of the contractor to terminate the subcontractor as a result of a breach and failure to cure by the subcontractor in no way waives or restricts the right of the contractor to declare a default and/or terminate the contract as a result of future breaches by the subcontractor. Article VIII-Dispute resolution/Jurisdiction and Venue Any dispute arising out of this subcontract shall be referred to the American Arbitration Association to arbitrate under the construction industry arbitration rules applicable as of the 114 N. Park Ave. Sanford FL 32771 Phone 407-647-7445 State License # CBC 1260967 date of this agreement* Unless, 1) the dispute involves a mechanics lien filed pursuant to chapter 13, Florida Statutes, in which case venue shall lie in the county where the real property is located. 2) The owner is parry to the litigation, or 3) the contract documents provide for a different venue. Article IX -Interchangeability of Terms The subcontractor recognizes that Philco Construction & Development, LLC. may be acting as a subcontractor, in which case the subcontractor hereunder may actually be a sub -subcontractor. In that event, the term "contractor", may be interchangeable with "subcontractor" as the context requires, and the term subcontractor as used herein shall refer to the entity contracting at the tier below Philco Construction & Development, LLC. whether as a subcontractor or sub - subcontractor. Contractor: Philc Co tru 77n & Development, LLC. ature { Signature t2 w a ,m s c vr RQ4 --f?/ S /la 4c• _(ZZ, Printed Name & Title Printed Name & Title 07/10/2018 Q — © Date Date Federal ID # Subcontractor: 114 N. Park Ave Sanford FL 32771 Phone 407-647-7445 State License# BC 1260967 4 Exhibit A List of Drawings Architect: Phase Zero Design Altitude Trampoline Park 1810 Rinehart Road Sanford, FL 32771 G001 5/16/2018 L1.00 5/16/2018 G002 4/4/2018 L2.00 5/16/2018 A101 4/4/2018 L3.00 5/16/2018 A111 5/16/2018 P101 4/4/2018 A131 5/16/2018 P201 4/4/2018 A201 4/4/2018 M 101 4/4/2018 A301 5/16/2018 M 201 4/4/2018 A302 5/16/2018 E101 4/4/2018 A303 5/16/2018 E102 4/4/2018 A401 5/16/2018 E201 4/4/2018 A402 4/4/2018 E301 4/4/2018 A501 5/16/2018 A502 4/4/2018 A503 5/16/2018 A504 5/16/2018 A601 5/16/2018