Loading...
HomeMy WebLinkAbout2921 Orlando Dr 18-3831; INTERIOR REMODEL0 (l SEP 10 ZU18 e 017 CITY OF SANFORD PERMIT APPLICATION BUILDING DIVISION Application No: 104A1 3 8 1 17 Documented Construction Value: $ d o v0 Job Address:s-, On Fey S07 f K 3Z773 Hi5 r 20U storic District: Yes No Parcel ID: 0) -a J ' 3u -5u% -0c) a a00 O Residential Commercial Type of Work: New Addition r Q Alteration El Description of Work: Q c`e_ 61j (_ Plan Review Contact Person: Repair Demo Change of Use Move I A E n / '"r Phone: Q7 ' Y99 -.3F Fax: Email:d/10-lluenCr nNf1P J Property Owner Inforr.ir =on Name St n o A Pl• `i`o:7 Street: &0, 90 %Vl Eif'hll/5 13 ( d * 161 I Resident of property?: N f F City, State Zip:0k050\n D P1 32Tr3S Contract . r " ifo- -:atinn Name i` - A 1e _v Street: 3fA" I. - City, State Zip: l c.--% a r" tone: 1/6 %) 7 Y— C r 6 Fax: State License No.: C Q C/ aS 9 0 3 7 Architect/Engineer Information Name: /_ 0 ns U` c• e,-, LLL Phone: 1(3 _ 3/ Q % Street: / '4 7 d)6 _W '0 6y Fax: 0/7) 7/ 29 City, St, Zip: o d "e Jd E-mail: Bonding Company: Address: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. W — f T N r, FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6" Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that t will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I ertify at all of the foregoing information is accurate and that all work will be done in compliance Signature of Owner/ laws regulating construction and zoning. Date Print Owner/Agent's Name ature of Nota - ate of Flor- a Date Yasmin Cook NOTARY PUBLIC STATE OF FLORID Own Comt 66 mown to M or Produc Ex irdlWYN28 L6 7 - 7,—/d Signature of Contractor/Agent Date fl)o r rI LA 101 0 Print,Contractor/ARentiflName ignatureofNYeafyin 189 orida Date II IZUPe Vzo SSTmt1 CC:: '1 VNOTARYPUBLIC STATE OF FLORIDA MI7200 ersonall Known to 'or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: W UTILITIES: FIRE: Fire Alarm Permit: Yes []No WASTE WATER: BUILDING:/d —.' - / r P so Bradenton Office Solutions, LLC 6000 Metrowest Blvd., Suite 101 Orlando, Florida 32835 407-499-2238 October 11, 2.018 Contractor Agreement Reference: 2921 S. Orlando Drive, Suite 200 THIS AGREEMENT is entered by and between Bradenton Office Solutions. LLC hereinafter called the "Owner" and Martin Toro Construction , nafter called the "Contractor". TERMS AND CONDITIONS Owner and Contractor undertake and agree as follows: The contractor shall furnish all labor, material, skill and equipment necessary or required to perform all the work for the Project as follows: Contractor to provide labor.and materials as shown on the Project Documents and plans. Contract price shall be (including all taxes and permit fees): $10,200. Project shall have a completion date no later than October 315t, 2018. I his Contract may not be modified in any manner unless in writing and signed by both parties. This document and any attachments hereto constitute the entire agreement between the Parties. This Contract shall be binding upon the Parties, their successors, heirs and assigns and shall be under the laws of the State of Florida r- fail/ y/«8 Date IAJVI., rG Martin i Signature 16)-11-19 Date 2 COUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 18100008 DATE: October 15, 2018BUILDINGAPPLICATION #: 18-10000843 BUILDING PERMIT NUMBER: 18-10000843 UNIT ADDRESS: ORLANDO DRIVE S 2921 STE 200 01-20-30.509-0000-2000 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT ADDADDRESS: 6000EMETROWESTR STAR OBLVDGSTE N101LORLANDO FL 32835 LAND USE: INTERIOR ALTERATION TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 2921 S ORLANDO DRIVE STE 200 / RETURN TO VANILLA SHELL FOR FUTURE TENANT / RETAIL BENEFIT RATE UNIT CALC UNIT TOTAL DUE FEE --- TYPE DIST SCHED RATE UNITS TYPE ROADS- ARTERIALS N/A ROADS - COLLECTORS N/A 00 FIRE RESCUE N/A 00 LIBRARY N/A 00 SCHOOLS N/A 00 PARKS N/A 00 LAW ENFORCE N/A 00 DRAINAGE N/A 00 AMOUNT DUE .00 00 PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE SEMINOLECOUNTYROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCEOFABUILDINGPERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TOAPPEALTHECALCULATIONOFANYOFTHEABOVEMENTIONEDIMPACTFEESMUSTBEEXERCISEDBYFILINGAWRITTENREQUESTWITHIN45CALENDARDAYSOFTHEDATEABOVEBUTNOLATERTHANCERTIFICATETFOCCUPAN6YOROCCUPANCY. pREVIEW MUST MEETTHEREQUIREMENTS OFTHECTHEREQUESTCOPIESOFRULESGOVERNINGAPPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE BUSINESS OFFICE: 1101EASTFIRSTSTREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRSTSTREETSANFORD, FL 32771 PAYMENT SHOULD BY CHECK OR MONEY SHOULD REFERENCE COUNTYUILDINGPMIT NMERATTHE TOPLLEFTOFTHIS STATEMENT. THISSTATEMENTISNOLONGERVALIDIF A BUILDING PERMIT IS NOT ISSUED WITHIN 60 CALENDAR DAYS FROM THEDATEABOVE CITY OF SEP 10 1U16 SANFO ;". PERMIT APPLICATION BUILDING DIVISION Application No: .38 ?) 1 Documented Construction Value: $ a 9 a l S. ,2tcn c, /)n Fe S F J'T. 30M 5cc fe 200 job Address: i C/I Historic District: Yes No Parcel ID: a-J - 3U Residential Commercial Type of Work: New Addition EKAlteration Repair Demo Change of Use Move Description of Work Plan Review Contact Person: Title: (h XP_A4Z Phone: YO 7 -V99 -38 Fax: Email:_O&d OtA- 4P &6.nZ'G ND2/I J _T v 01M Property Owner Information Name S(t 6aQ n o (&kr- Ul- Phone: 0-- Street: &000 AJ &h-I_s 3 c (Id * cd I Resident of property?: N f P City, State Zip:0kb901 rJ a P1 3 7 -3S Contractor Information Name v n Street: / 1 - , may City, State Zip: Phone: G/a % ) 7 - G lf Fax: State License No.: r Architect/Engineer Information Name: 0 C-S All c, Phone: a -7 7 Street: % JV S4 7 d 6y Fax:/S a 7t S1 City, St, Zip: ` C' G , % % E-mail: f S 12 S%S Bonding Company_ Mortgage Lender:. Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE_OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6' Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I e. done in compliance ll a Signature of Owner/ all of the foregoing information is accurate and that all work will be laws regulating construction and zoning. Date Print Owner/Agent's Name ature of Nota - ate of Flort a Date SpR Yasmin Cook NOTARY PUBLIC ESTATE OF FLORID Own Cmialfta nown to M or Producr 0 Ex iret€*WZ0a8 O Signature of Contractor/Agent Date MO. r'I " 1/ 1 ') t 17 Prin t.Contractor/AeenCgName lotary/inw orida YaSSRmltn Date ('r /7/2_0I 1 NOTARY PUBLIC STATE OF FLORIDA Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Known to or Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: COMMENTS: FIRE: BUILDING: CURp. • aBUILDING DIVISION SEP 10 ZU16 PERMIT APPLICATION Application No: Ik-38-)l A Documented Construction Value: $ /d 0 t)0 Job Address: ! U` S U9-tC11A l n F2 .SCiI % 3ZT7 5v ZOU Historic District: Yes No Parcel ID: a-J '*3u -5" -UcJd a '"0100O Residential Commercial Type of Work: New Addition []"Alteration Repair Demo Change of Use Move Description of Work: Plan Review Contact Person: Phone- * 7 -V99 -.A5Z38 Fax: Title: fh RZL Email:_ 0&dA0tA- 94f2 oiluP tLr_TP.C q'V" r 1 rr Property Owner Information N c 0 1 CLL Phone: C- NameS((:7— Street: & 0ao 41 &i'11lI/ -S 13 ( (/d, * 01 Resident of property? : N (P City, State Zip.Qk(RP Y:) b P1 3 2 35 Contractor Information Name - A v Street: At City, State Zip: i Phone: 0 % -) i 4 — G lf a Fax: State License No.: C C/ aS 9 0 37 r j Architect/ Engineer Information Name: /_ c's U c. C-"L i- LLL Phone: Street: 0<7o) /J S4 td'bSIC 0 6y Fax: y 7 /Clog a 7/ l / City, St, Zip: 0d'(fJy >l'G E-mail: L.-L1St''QS T Bonding Company_ Mortgage Lender:- Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 61 Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT. done in compliance Signature of all of the foregoing information is accurate and that all work will be laws regulating construction and zoning. Date gl e_y . &,e .Q Print Owner/Agent's Name ature of Nota - ate of Flon a Date Epp Yasmin Cook NOTARY PUBLIC STATE OF FLORID Own ciunixiftafaab nown to M or Product' Ex irer€)4W2021) 7 ,/U Signature of Contractor/Agent Date A I kA I IYeSfrlin No onda Date G /7/2_10 I1 NOTARY PUBLIC STATE OF FLORIDA Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Known to or Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Fire Alarm Permit: Yes No ' b WASTE WATER: 1 BUILDING: SEP 10 1U1 CITY OF SA N O PERMIT APPLICATION a RD BUILDING DIVISION Application No: .38 Documented Construction Value: $ // Q 0 ( 0 a q al S U LCcnoQc, do Fe S , ` 32713 5cc(g Zov Job Address: i 'm fit - K Historic District: Yes No Parcel ID: % a 0 30 -Oc)c' a 2-0t) O Residential Commercial E Type of Work: New Addition [3'Alteration Repair Demo[] Change of Use Move Description of Work: Je GI, t 1L) k1l A 4 Q!-" Plan Review Contact Person: --t n Phone: YQ 7 -Y99 -239 Fax: Email:0&dA 0LA - 6A0 OhuP t nNDP J ` Property Owner Information Name Phone: ( —% 9 Street: &Oon Al P &R-S 3 U ld * 101 Resident of property?: N f ,4 City, State Zip.OkOOPM b El 3 2-Z3S Contractor Information Name -A v Street 0 at City, State Zip: Phone: G/6 % ) 7 — G lf F Fax: State License No.: L-9 C/ dS 9 O 3% Architect/Engineer Information / l Name: c's G c. "' t' L L L Phone: % a 3 1 Q 7 Street: 10 S4 /dk syc yo 6y Fax - O/S a 7r 29 City, St, Zip: (f JC) 1-E-mail: l Qs Bonding Company_ Mortgage Lenden- Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE -OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 60' Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I e. done in compliance ll a Signature of Owner/ all of the foregoing information is accurate and that all work will be laws regulating construction and zoning. Date e,y-. Kle-e-o e Print Owner/Agent's Name ature of Nota - tate of Flon a Date Yasmin Cook NOTARY PUBLIC STATE OF FLORID Own CommtP6L3St3 mown to M or Product''W Expirer€y-RZ5a8 O'249; --/el Signature of Contractor/Agent Date 00, '9 Prin t.Con tractor/AeenMamC g.nalureolNytaanat40 onda DateI7IZ6r ARCC;; NOTARY PUBLIC S STATE OF FLORIDA MoC m# t 018400 ersonall Known to or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: FIRE: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: COMMENTS: is wr Ii i.c.-.'o.- Su; Id - ouf a % sh.,., r, ar U i y •ALL BUILDING DIVISION SEP 10 ZU16 < PERMIT APPLICATION Application No: I k - 3 8 C Documented Construction Value: $ Job Address: j 1 ' u ' n SCiJ f7A t -- 3OW3 Histori District: Yes No[] Parcel ID: a-J - 3u -5ul -Uyc' a -o100 v Residential Commercial Type of Work: New Addition [3/Alteration Repair Demo Change of Use Move Description of Work: Plan Review Contact Person: fi7'i'1 Phone: YQ Z -Y99 -AZY Fax: Title: // i1 g Email: d dA- 6(AlorzrriiloPJtCG TP.0 Jgqi?N U Property Owner Information Name S V P S ,or, 1 Q x Phone: Street: I n Al P,h-ll_S 3 e v e I Resident of property?: N f p City, State Zip:OUAPOO d P1 3 2C35 Contractor Information l Name Ct Street 0 A 6. f J City, State Zip: Phone: L/a % ) 7 4 — C//'E/ Fax: State License No:: L- 9 C I aS 9 C •3 7 r Architect/Engineer Information Name: /- c's l' Gf6d ., t LL L Phone: Street: <7d 10 s4 Ala s- o 67 Fax i 61 a 7/ S9 I l/ City, St, Zip: 0 d C'y E-mail: ( _ e S, N Bonding Company_ —mortgage-Lender- Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6`s Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: done in compliance Signature of Owner/Agent all of the foregoing information is accurate and that all work will be laws regulating construction and zoning. Date Print Owner/Agent's Name ature of Nota - to of Flon a Date SQ,% RYasmin Cook NOTARY PUBLIC STATE OF FLORIDOwnCnmm#6L f nown to M or Produal Ex ireT,#VW22) g4 7 Signature of Contractor/Agent Date l7 Iotwir, t8o onda Date No1Yar un "1.L.v NOTARY PUBLIC STATE OF FLORIDA Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Known to Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads _ APPROVALS: ZONING: ENGINEERING: COMMENTS: Fire Alarm Permit: Yes No UTILITIES: /WASTE WATER: FI % a BUILDING: Grant Maloyy, Clerk Of The Circuit Court & Comptroller Seminole County, FLInst #2018102787 Book:9206 Page:843; (1 PAGES) RCD: 9/10/2018 2:39:33 PM C` THIS INSTRUN RED BY, (A ' of C+ Address: rVl t NOTICE OF COMMENCEMENT' CERTIFIED COPY GRANT MALOY CLERK 0. THE CIRCUIT COURT joANDCOMPTROLLER SEMINOLEC C;TYORIDA6Y DKdata State of Florida County of Seminole / j ^ 1 ` ' 1 /j/) _ d PermitNumber. 9 — CoC 0 is 3 ' Parcel ID Number: V 1 - 21V - 3 v - I -yO 0 dL The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713. Florida Statutes, the following Information Is provided In this Notice of Commencement. DESCRIPTION OF GENERAL DYCRIPTION OF IMPROYEM T: j 1 / C% aC, G- 1,,,c 1) 1 1 Pi r &— /A )nl IS 7 J 6-e zo le Fee Simple Title Holder (if other than owner) Name: CONTRACTOR: 3 Name: 0` 4 r 4 . 6 C'U C O,n / r -t Address: S() ,. , n / A1, 4..,.1_, i_ Parsons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: In addition to himself. Owner Designates of To receive a copy of the Llenor's Notice as Provided In Section 713. 13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date Is specified) WARNING TO OVANER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPR PER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESUL OUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MU RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND O AIN FINANCING. CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCI OR CORDING YOUR NOTICE OF COMMENCEMENT. Under penalt' of per clare that ave read the foregoing and that the facts stated In It are true to the bes f n I d-b0 le. Ale( _eeec c no Signaturo owner's Pdntm Name Florida Statute 3.r Xg): ' The owner must sign the notice of commencement and no on• use my bo poeNrloo to sign in his of her stead' State of County of Jf'znncj pp jj77n,-, The foregoing Instrum",[/mot wpas acknowledged before me this day of (/LPFgM1/ if rf, Zp by > ' - e C- e- Who is personally known to me Yd Name of person making statement OR who has produced identification type of Identification produced: Yesmin Cook NOTARY PUBLIC 144 oSTATE OFFLORIDACommayGG184000Nota "LE1° Expires217/2022 CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION FIRE PLAN REVIEW SERVICE FEES PHONE: 407.688.5052 FAX: 407.688.5051 G3 DATE: /1f PERMIT NUMBER: It-2 BUSINESS/PROJECT NAME: ADDRESS: 5-t, Zoo CONTACT NAME: PHONE: PLAN REVIEW INFORMATION CONSTRUCTION [ ]C/O [ ] FIRE ALARM [ ] FIRE SPRINKLER []HOOD [ ]PAINT BOOTH [ ]TANK DOES 20% REDUCTION IN FIRE IMPACT FEES APPLY: YES NO TOTAL FEES: i r INSPECTION SEQUENCE BP# 18-3831 ADDRESS: 2921 S. Orlando Drive BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Slab / Mono Slab Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In 10 Frame Insulation Rough Firewall Screw Pattern 20 Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com'l) Building Ceiling Grid Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence Final Commercial — 1000 Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) ELECTRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough Electric Rough Pre -Power Final Temporary Pole Electric Final B.M, PERMITinrimMaxInspectionDescription Rough Plumb Plumbing Underground Plumbing 2"d Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough Plumbing Final MECHANICAL PERMIT Min Max Inspection Description Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap Mechanical Final REVISED: June 2014 4--L AUG Q 120 f CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: 3L 55 Documented Construction Value: S Job Address: 2921 S ORLANDO DRIVE, Sanford, FL, 32773 Historic District: Yes No Parcel ID: 01203050900002600 Residential Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: WIRELESS ANTENNA UPGRADE UI W10 Plan Review Contact Person: Betty Tufford Title: Permitting Specialest Phone: 561-633-5250 Fax: Email: batufford@tepgroup.net Tower Owner Information Name ATC Sequoia LLC Phone: 781-926-4500 Street: _10 Presidential Way Resident of property? no City, State Zip: Woburn MA 01801 Contractor Information Name I V1"(-- ro kd Phone: C6 13 -Gl R LP - q Ct 2- Street: G33I C- r-OUJlev- h Vf- Fax: City, State Zip:_11CY)AYASSq 1=L 335q :; State License No.: C«ouaaaa Architect/Engineer Information Name: TEP GROUP /Graham Andres Phone: Street: 326 Tryon Road Fax: City, St, Zip: Raleigh NC 27603 Bonding Company: n/a Address: n/a 919-661-6351 E-mail: gandres@tepgroup.net Mortgage Lender: Address: n/a WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised June 30, 2015 S / 3. Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify -the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in co li nce with all applicable laws regulating construction and zoning. By: r Signature of Tower Owner/Agent Date Signature of Co for/Agent Date Maazgaret Robinson, Senior Counsel, ATC Sequoia LLC Print Owner/Agent's Name J MELISSA ANN METZLER 111 Notary Public Commonwealth of Massachusetts Commission Expires March 14, 2025 Tower Owner/Agerif is x-----1'er: Produced ID Type of ID 5 `1- Date to Me or Print Contractor/Agent's Name Etxxa . L9/3f1 Date TEENA N. MILLER Commission # FF 145743 d- s Expires November 28, 2018 f orM1c:,Bondod Tlw Troy Foul Insumra E00-785-70ig Contractor/Agent is t1 Personally Known to Me or rgo u ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps, Fire Sprinkler Permit: Yes No # of Heads ll^ APPROVALS: ZONING:CPi'ILITIES: ENGINEERING: COMMENTS: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: F— .z k 1 d' As shown on plan, ok for antenna upgrade on existing 98.8 foot monopole communication tower at 2931 Orlando Drive. The Orlando Sanford -International Airport must be contacted if any cranes are used. Revised: June 30, 2015 Permit Application INSPECTION SEQUENCE BP# 18-3435 ADDRESS: 2921 S. Orlando Drive BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Slab / Mono Slab Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough Firewall Screw Pattern Drywall / Sheetrock Lath Ins ection Building Ceiling Air Barrier Insulation Roof (Com' 1) Building Ceiling Grid Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence Final Commercial — Final Commercial — Addition / Alteration Final Commercial — Change of Use 1000 Final Building (Other) Antenna upgrade ELECTRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough Electric Rough Pre -Power Final Temporary Pole Electric Final 1PL MBING PERMIT Min Max Inspection Description Rough Plumb Plumbing Underground Plumbing 2"d Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough Plumbing Final MECHANICAL PERMIT Min Max Inspection Description Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap Mechanical Final REVISED: June 2014 I . t OFFICE Ak AMERICAN TOWER" C O R P O R A T I O N Structural Analysis Report Structure 98.8 ft Monopole ATC Site Name Sanford FL, FL ATC Site Number 412281 Engineering Number : OAA724774_C3_01 Proposed Carrier T-Mobile Carrier Site Name SANFORD PLAZA Carrier Site Number 132046 Site Location 2921 S ORLANDO DRIVE Sanford, FL 32773-8029 28.771400,-81.275800 County SEMINOLE Date February 23, 2018 Max Usage 86% Result Pass Prepared By: Reviewed By Adam Pittman Structural Engineer II PERMIT # 2 e- 1LjA t VIA 48 p STATE OF Feb 26 2018 3:36 PM cosign COA: 9053 ATC Tower Services LLC - 3S00 Regency Parkway, Suite 100 - Cary, NC 27518 - 919-468-0112 Office - 919-466-5414 Fax - www.americantower.com A AMERICAN TOWER• c o e r o 0 A 1 o n Table of Contents Eng. Number OAA724774_C3_01 February 23, 2018 Introduction....................................................................................................................................................... 1 SupportingDocuments..................................................................................................................................... 1 Analysis............................................................................................................................................................... 1 Conclusion.......................................................................................................................................................... 1 Existing and Reserved Equipment................................................................................................................... 2 Equipmentto be Removed.............................................................................................................................. 2 ProposedEquipment........................................................................................................................................ 2 StructureUsages.................................................................................................................................................3 Foundations........................................................................................................................................................ 3 Deflection, Twist, and Sway.............................................................................................................................. 3 StandardConditions...........................................................................................................................................4 Calculations.......................................................................................................................................... Attached ATC Tower Services LLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919.468-0112 Office - 919-466-5414 Fax - www.americantower.com AMERICANTOWER" CORPO RAT ION Introduction Eng. Number OAA724774_C3_01 February 23, 2018 Page 1 The purpose of this report is to summarize results of a structural analysis performed on the 98.8 ft monopole to reflect the change in loading by T-Mobile. Supporting Documents Tower Drawings HighTower Mapping Site #412281, dated October 3, 2016 Geotechnical Report ATC Project #31.19385.0037, dated July 24, 2000 Analysis The tower was analyzed using American Tower Corporation's tower analysis software. This program considers an elastic three-dimensional model and second -order effects per ANSI/TIA-222. Basic Wind Speed: 110 mph (3-Second Gust, Vasd) / 139 mph (3-Second Gust, Vult) Basic Wind Speed w/ Ice: No Ice Considered Code: ANSIJTIA-222-G / 2015 IBC / 6th Ed. (2017) Florida Building Code Structure Class: II Exposure Category: B Topographic Category: 1 Crest Height: 0 ft Spectral Response: Ss = 0.08, S1= 0.04 Site Class: D - Stiff Soil Conclusion Based on the analysis results, the structure meets the requirements per the applicable codes listed above. The tower and foundation can support the equipment as described in this report. If you have any questions or require additional information, please contact American Tower via email at Engineering@americantower.com. Please include the American Tower site name, site number, and engineering number in the subject line for any questions. ATC Tower Services LLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518-919-468.0112 Office - 919.466.5414 Fax - www.americantower.com Eng. Number OAA724774_C3_01AFebruary23, 2018 AMERICAN TOWER• Page 2 C O A r O A A T 1 O N Existing and Reserved Equipment Elevation' (ft) 4tY Antenna Mount Type Lines Carrier Mount RAD 98.0 98.0 3 Commscope CBC721-DF-2X Platform w/ Handrails 9) 15/8" Coax 1) 1.58" Hybrid Verizon 3 Ericsson RRUS 32 w/ Solar Shield (52.9 Ibs) 1 Raycap RRFDC-3315-PF-48 6 JMA Wireless C7CQCAP-FRO-656-VRO 1 VZW Unused Reserve: 17,135 sq in Equipment to be Removed Elevation' (ft) QtY Antenna Mount Type Lines Carrier Mount RAD Ericsson RRUS 32 w/ Solar Shield (52.9 3 Ibs) 98.0 98.0 5Coax Verizon 3CommscopeCBC721DF-2X 11)) 158" Hybrid 3 Commscope ATSBT-TOP-FM-4G 3 Antel BXA-70063/6CF_ Proposed Equipment Elevation' ( ft) 4ty Antenna Mount Type Lines Carrier Mount RAD 98. 0 98.0 6 Ericsson Radio 2212 132/1366A Platform w Handrails an2) 15/8" Fiber Verizon 3 Ericsson Radio 2212 1313/135 3 CommscopeTD-PCS-I-B3B4-BSE 1 1 Raycap RCMDC-6627-PF-48 Mount elevation is defined as height above bottom of steel structure to the bottom of mount, RAD elevation is defined as center of antenna above ground level (AGL). Install proposed coax outside the pole shaft. Stacking coax is not allowed. ATC Tower Services LLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919-469.0112 Office - 919-466-5414 Fax - www americantower.com Eng. Number OAA724774_C3_01AFebruary23, 2018 AMERICAN TOWER• Page 3 C O A e 0 A A T 1 0 N Structure Usages Structural Component Controlling Usage Pass/Fail Shaft 86% Pass Foundations Reaction Component Analysis Reactions of Usage Moment (Kips -Ft) 1,330.0 34% Axial (Kips) 57.5 18% The structure base reactions resulting from this analysis were found to be acceptable through analysis based on geotechnical and foundation information, therefore no modification or reinforcement of the foundation will be required. ATC Tower Services LLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919-468-0112 Office - 919-466-5414 Fax - www americantower com A AMERICAN TOWER' C G R P G R n T 1 C x Standard Conditions All engineering services performed by ATC Tower Services LLC are prepared on the basis that the information used is current and correct. This information may consist of, but is not limited to the following: Information supplied by the client regarding antenna, mounts and feed line loading Information from drawings, design and analysis documents, and field notes in the possession of ATC Tower Services LLC It is the responsibility of the client to ensure that the information provided to ATC Tower Services LLC and used in the performance of our engineering services is correct and complete. All assets of American Tower Corporation, its affiliates and subsidiaries (collectively "American Tower") are inspected at regular intervals. Based upon these inspections and in the absence of information to the contrary, American Tower assumes that all structures were constructed in accordance with the drawings and specifications. Unless explicitly agreed by both the client and ATC Tower Services LLC, all services will be performed in accordance with the current revision of ANSI/TIA-222. All services are performed, results obtained, and recommendations made in accordance with generally accepted engineering principles and practices. ATC Tower Services LLC is not responsible for the conclusions, opinions and recommendations made by others based on the information supplied herein. ATC Tower Services LLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919-468-0112 Office - 919-466.5414 Fax - www.americantower.com Job Number: OAA724774 Site Name: Sanford FL, FL Engineer: Adam.Pittman Date: 02/23/18 Design Criteria Code Input: TIA-222-G Design Windspeed: 1^16 mph GH: 1.10 Height of Crest: 6 ft Ice Windspeed: jO mph Radial Ice: 0`•60 in Operational Windspeed: M--40 mph W Load Factor: W;Load Factor: 1.0 Weight of Ice: S6 pcf Cross -sectional Dimensions Base Section (1): Base Width: 42.34 in Top Width: 26)0 in Base Thickness: 6.00 in Top Thickness: 3.75 in Length: 98.75 ft Seismic Analysis Method Kp: 0.95 Topo. Category: 1 Structure Class: II Exposure: B' D Load Factor 1: L2 D Load Factor 2: 0 9 E Load Factor: 1;0 D, Load Factor: Yb Ignore R. Effect: N 1 Number of Sections Equivalent Lateaal'FOfCe Procedure =-- Site Class: -D Wind Importance: 1.00 Wind with Ice Importance: 1.00 Ice Thickness Importance: 1.00 Earthquake Importance: 1.00 S,. Sl: O.046 For Mapped Poles Top of Tower: _ 98:.75.ft Base Moment Override: y Concrete Strength (f'c): 12060 psi Moment Capacity: 1721 k-ft Concrete Unit Weight: 145'pcf Concrete Elastic Modulus: 5381780 psi Concrete Rupture Strength: 822 psi r- Site Number: OAA724774 Site Name: Sanford FL, FL Engineer: Adam.Pittman Date: 2/23/2018 Code Input: TIA-222-G Antenna/Mount Mechanical Properties, Wind, Weight and Ice Loads Antenna Name & Man.) Height in) Width in) Depth in) Round Flat R/F) Weight lb) Total Orient. Factor Elev. ft) KA Ant.) Ice Thickness in) K, C. EPA Bare ft') EPA Ice ft) i Wt. Bare lb) E Wt. Ice lb) 2212 B2/B66A 16.5 13.5 6.3 F 43.0 6 0.50 98.0 0.75 0.00 1.00 1.20 4.2 4.2 258 258 CBC721-DF-2X (11.51b) 7.7 6.0 3.7 F 11.5 3 0.50 98.0 0.75 0.00 1.00 1.20 0.4 0.4 35 35 RRUS 32 w/ S.S. 27.2 12.1 7.0 F 52.9 3 0.50 98.0 0.75 0.00 1.00 1.20 3.1 3.1 159 159 RRFDC-3315-PF-48 28.7 11.7 10.3 F 32.0 1 0.50 98.0 0.75 0.00 1.00 1.20 1.0 1.0 32 32 2212 B13/B5 16.5 13.5 5.9 F 44.1 3 0.50 98.0 0.75 0.00 1.00 1.20 2.1 2.1 132 132 C7CQCAP-FRO-656-VRO 72.0 18.8 10.2 F 53.2 6 0.67 98.0 0.75 0.00 1.00 1.26 35.7 35.7 319 319 TD-PCS-I-B3B4-BSE 18.3 14.4 3.5 F 35.5 3 0.50 98.0 0.75 0.00 1.00 1.20 2.5 2.5 107 107 RCMDC-6627-PF-48 29.5 16.5 12.6 F 32.0 1 0.50 98.0 0.75 0.00 1.00 1.20 1.5 1.5 32 32 12 13 14 15 Mount Type) CAAc Bare ft') CAAc Ice ft)(lb) Weight Bare Weight Ice Ib) KA Mnt.) E EPA Bare ft) i EPA Ice ft) KZ Qz Bare Psf) QZ Ice Psf) FA Bare lb) FA Ice lb) E Wt. Bare lb) E Wt. Ice lb) R. Platform w/ HR 27.2 2000.0 1.00 31.4 4.2 0.983 28.86 2.15 996 10 2258 258 VZW Unused Reserve 119.1 1426.8 1.00 119.5 0.4 0.983 28.86 2.15 3794 1 1461 35 Platform Kickers 5.0 225.0 1.00 8.1 3.1 0.983 28.86 2.15 257 7 384 159 4 1.0 1.0 0.983 28.86 2.15 33 2 32 32 5 2.1 2.1 0.983 28.86 2.15 66 5 132 132 6 35.7 35.7 0.983 28.86 2.15 1133 84 319 319 2.5 2.5 0.983 28.86 2.15 78 6 107 107 8 1.5 1.5 0.983 28.86 2.15 48 4 32 32 9 10 11 12 13 14 15 Site Number: OAA724774 Site Name: Sanford FL, FL Engineer: Adam.Pittman Date: 02/23/18 Code Input: TIA-222-G Tower Section Properties Elevation ft) Base O.D. in) Top O.D. in) Thickness in) Base I.D. in) Top I.D. in) P.W. in) P.W. F / R W,.ax lb/ft) R. Inertia in4) Area in) Section Modulus in') Section Cracked in4) 3.29 42.34 41.61 6.00 30.34 29.61 1.98 R 12.2 0.047 37583 678 5485 Yes 6.58 41.61 40.89 5.93 29.76 29.04 1.98 R 12.2 0.048 35158 658 5223 Yes 9.88 40.89 40.17 5.85 29.19 28.47 1.98 R 12.2 0.049 32853 637 4970 Yes 13.17 40.17 39.45 5.78 28.62 27.90 1.98 R 12.2 0.050 30661 617 4724 Yes 16.46 39.45 38.73 5.70 28.05 27.33 1.98 R 12.2 0.051 28581 598 4487 Yes 19.75 38.73 38.01 5.63 27.48 26.76 1.98 R 12.2 0.052 26608 579 4257 Yes 23.04 38.01 37.28 5.55 26.91 26.18 1.98 R 12.2 0.053 24738 560 4036 Yes 26.33 37.28 36.56 5.48 26.33 25.61 1.98 R 12.2 0.054 22967 541 3822 Yes 29.63 36.56 35.84 5.40 25.76 25.04 1.98 R 12.2 0.055 63879 523 3616 No 32.92 35.84 35.12 5.33 25.19 24.47 1.98 R 12.2 0.056 59133 504 3417 No 36.21 35.12 34.40 5.25 24.62 23.90 1.98 R 12.2 0.057 54656 487 3226 No 39.50 34.40 33.68 5.18 24.05 23.33 1.98 R 12.2 0.058 50435 469 3041 No 42.79 33.68 32.96 5.10 23.48 22.76 1.98 R 12.2 O.OS9 46462 452 2864 No 46.08 32.96 32.23 5.03 22.91 22.18 1.98 R 12.2 0.061 42726 435 2694 No 49.38 32.23 31.51 4.95 22.33 21.61 1.98 R 12.2 0.062 39219 419 2530 No 52.67 31.51 30.79 4.88 21.76 21.04 1.98 R 12.2 0.064 35930 402 2373 No SS.96 3079 30.07 4.80 21.19 20.47 1.98 R 12.2 0.065 32850 386 2223 No 59.25 30.07 29.35 4.73 20.62 19.90 1.98 R 12.2 0.067 29971 371 2079 No 62.54 29.35 28.63 4.65 20.05 19.33 1.98 R 12.2 0.068 27284 356 1941 No 65.83 28.63 27.91 4.58 19.48 18.76 1.98 R 12.2 0.070 24780 341 1810 No 69.13 27.91 27.18 4.50 18.91 18.18 1.98 R 12.2 0.072 22450 326 1684 No 72.42 27.18 26.46 4.43 18.33 17.61 1.98 R 12.2 0.074 20287 311 1564 No 75.71 26.46 25.74 4.35 17.76 17.04 1.98 R 12.2 0.076 18283 297 1450 No 79.00 25.74 25.02 4.28 17.19 16.47 1.98 R 12.2 0.078 16429 283 1341 No 82.29 25.02 24.30 4.20 16.62 15.90 1.98 R 12.2 0.080 14718 270 1238 No 85.58 24.30 23.58 4.13 16.05 15.33 1.98 R 12.2 0.083 13143 257 1140 No 88.88 23.58 22.85 4.05 15.48 14.75 1.98 R 12.2 0.085 11696 244 1048 No 92.17 22.85 22.13 3.98 14.90 14.18 1.98 R 12.2 0.088 10371 231 960 No 95.46 22.13 21.41 3.90 14.33 13.61 1.98 R 12.2 0.091 9160 219 877 No 98.75 21.41 20.69 3.83 13.76 13.04 1.98 R 12.2 0.094 8056 207 799 No Site Number: OAA724774 Site Name: Sanford FL, FL Engineer: Adam.Pittman Date: 02/23/18 Code Input: TIA-222-G Shaft Wind and Dead loads Elevation ft) Average O.D. in) R. C Cr K, K„ Shaft E.P.A. ft) C,EPA ft') App. C, E.P.A. ft) Q, Pst) F, lb) Pole Weight lb) App. Weight lb) Total Weight lb) 3.29 41.97 0.05 322 0.60 0.70 1.00 11.51 6.91 0.00 20.56 156 2248 40 2288 6.58 41.25 0.05 316 0.60 0.70 1.00 11.32 6.79 0.00 20.56 154 2180 40 2220 9.88 40.53 0.05 311 0.60 0.70 1.00 11.12 6.67 0.00 20.56 151 2113 40 2153 13.17 39.81 0.05 305 0.60 0.70 1.00 10.92 6.55 0.00 20.56 148 2047 40 2087 16.46 39.09 0.05 299 0.60 0.70 1.00 10.72 6.43 0.00 20.56 145 1982 40 2022 19.75 38.37 0.05 294 0.60 0.70 1.00 10.52 6.31 0.00 20.56 143 1918 40 1958 23.04 37.65 0.05 288 0.60 0.70 1.00 10.33 6.20 0.00 20.56 140 1855 40 1895 26.33 36.92 0.05 283 0.60 0.70 1.00 10.13 6.08 0.00 20.56 137 1793 40 1833 29.63 36.20 0.05 277 0.60 0.70 1.00 9.93 5.96 0.00 20.56 135 1732 40 1772 32.92 35.48 0.06 274 0.60 0.71 1.00 9.73 5.84 0.00 20.82 134 1672 40 1712 36.21 34.76 0.06 272 0.60 0.73 1.00 9.53 5.72 0.00 21.42 135 1613 40 1654 39.50 34.04 0.06 270 0.60 0.75 1.00, 9.34 5.60 0.00 21.99 135 1555 40 1596 42.79 33.32 0.06 267 0.60 0.77 1.00 9.14 5.48 0.00 22.52 136 1498 40 1539 46.08 32.59 0.06 264 0.60 0.78 1.00 8.94 5.36 0.00 23.02 136 1443 40 1483 49.38 31.87 0.06 261 0.60 0.80 1.00 8.74 5.25 0.00 23.49 136 1388 40 1428 52.67 31.15 0.06 258 0.60 0.82 1.00 8.55 5.13 0.00 23.95 135 1334 40 1374 55.96 30.43 0.07 254 0.60 0.83 1.00 8.35 5.01 0.00 24.38 134 1281 40 1321 59.25 29.71 0.07 250 0.60 0.84 1.00 8.15 4.89 0.00 24.79 133 1229 40 1270 62.54 28.99 0.07 246 0.60 0.86 1.00 7.95 4.77 0.00 25.19 132 1178 40 1219 65.83 28.27 0.07 242 0.60 0.87 1.00 7.75 4.65 0.00 25.57 131 1129 40 1169 69.13 27.54 0.07 237 0.60 0.88 1.00 7.56 4.53 0.00 25.94 129 1080 40 1120 72.42 26.82 0.07 232 0.60 0.90 1.00 7.36 4.41 0.00 26.29 128 1032 40 1072 75.71 26.10 0.08 228 0.60 0.91 1.00 7.16 4.30 0.00 26.64 126 985 40 1026 79.00 25.38 0.08 223 0.60 0.92 1.00 6.96 4.18 0.00 26.97 124 939 40 980 82.29 24.66 0.08 218 0.60 0.93 1.00 6.76 4.06 0.00 27.29 122 895 40 935 85.58 23.94 0.08 213 0.60 0.94 1.00 6.57 3.94 0.00 27.61 120 851 40 891 88.88 23.22 0.09 207 0.60 0.95 1.00 6.37 3.82 0.00 27.91 117 808 40 849 92.17 22.49 0.09 202 0.60 0.96 1.00 6.17 3.70 0.00 28.21 115 767 40 807 95.46 21.77 0.09 196 0.60 0.97 1.00 5.97 3.58 0.00 28.50 112 726 40 766 98.75 21.05 0.09 191 0.60 0.98 1.00 5.77 3.46 0.00 28.78 110 686 40 726 Site Number: OAA724774 Site Name: Sanford FL, FL Engineer: Adam.Pittman Date: 02/23/18 Code Input: TIA-222-G Shaft Concurrent Ice + Wind Loads & Ice Weight Elevation ft) Average Width in) Ice Thickness in) R. Cf K, Kn Shaft EPA ft`) C,EPA ft`) App. C, E.P.A. ft`) Q. Psf) F, lb) Pole Ice Weight lb) App. Ice Weight lb) Total Weight lb) 3.29 41.97 0.00 0.05 1.20 0.70 1.00 11.51 13.82 0.65 1.53 24 2248 40 2288 6.58 41.25 0.00 0.05 1.20 0.70 1.00 11.32 13.58 0.65 1.53 24 2180 40 2220 9.88 40.53 0.00 0.05 1.20 0.70 1.00 11.12 13.34 0.65 1.53 24 2113 40 2153 13.17 39.81 0.00 0.05 1.20 0.70 1.00 10.92 13.10 0.65 1.53 23 2047 40 2087 16.46 39.09 0.00 0.05 1.20 0.70 1.00 10.72 12.87 0.65 1.53 23 1982 40 2022 19.75 38.37 0.00 0.05 1.20 0.70 1.00 10.52 12.63 0.65 1.53 22 1918 40 1958 23.04 37.65 0.00 0.05 1.20 0.70 1.00 10.33 12.39 0.65 1.53 22 1855 40 1895 26.33 36.92 0.00 0.05 1.20 0.70 1.00 10.13 12.15 0.65 1.53 22 1793 40 1833 29.63 36.20 0.00 0.05 1.20 0.70 1.00 9.93 11.92 0.65 1.53 21 1732 40 1772 32.92 35.48 0.00 0.06 1.20 0.71 1.00 9.73 11.68 0.65 1.55 21 1672 40 1712 36.21 34.76 0.00 0.06 1.20 0.73 1.00 9.53 11.44 0.65 1.60 21 1613 40 1654 39.50 34.04 0.00 0.06 1.20 0.75 1.00 9.34 11.20 0.65 1.64 21 1555 40 1596 42.79 33.32 0.00 0.06 1.20 0.77 1.00 9.14 10.97 0.65 1.68 21 1498 40 1539 46.08 32.59 0.00 0.06 1.20 0.78 1.00 8.94 10.73 0.65 1.72 21 1443 40 1483 49.38 31.87 0.00 0.06 1.20 0.80 1.00 8.74 10.49 0.65 1.75 21 1388 40 1428 52.67 31.15 0.00 0.06 1.20 0.82 1.00 8.55 10.25 0.65 1.78 21 1334 40 1374 55.96 30.43 0.00 0.07 1.20 0.83 1.00 8.35 10.02 0.65 1.82 21 1281 40 1321 59.25 29.71 0.00 0.07 1.20 0.84 1.00 8.15 9.78 0.65 1.85 21 1229 40 1270 62.54 28.99 0.00 0.07 1.20 0.86 1.00 7.95 9.54 0.65 1.88 21 1178 40 1219 65.83 28.27 0.00 0.07 1.20 0.87 1.00 7.75 9.30 0.65 1.91 21 1129 40 1169 69.13 27.54 0.00 0.07 1.20 0.88 1.00 7.56 9.07 0.65 1.93 21 1080 40 1120 72.42 26.82 0.00 0.07 1.20 0.90 1.00 7.36 8.83 0.65 1.96 20 1032 40 1072 75.71 26.10 0.00 0.08 1.20 0.91 1.00 7.16 8.59 0.65 1.99 20 985 40 1026 79.00 25.38 0.00 0.08 1.20 0.92 1.00 6.96 8.35 0.65 2.01 20 939 40 980 82.29 24.66 0.00 0.08 1.20 0.93 1.00 6.76 8.12 0.65 2.03 20 895 40 935 85.58 23.94 0.00 0.08 1.20 0.94 1.00 6.57 7.88 0.65 2.06 19 851 40 891 88.88 23.22 0.00 0.09 1.20 0.95 1.00 6.37 7.64 0.65 2.08 19 808 40 849 92.17 22.49 0.00 0.09 1.20 0.96 1.00 6.17 7.40 0.65 2.10 19 767 40 807 95.46 21.77 0.00 0.09 1.20 0.97 1.00 5.97 7.17 0.65 2.12 18 726 40 766 98.75 21.05 0.00 0.09 1.20 0.98 1.00 5.77 6.93 0.65 2.14 18 686 40 726 Site Number: OAA724774 F.: Site Name: Sanford FL, FL F,,: Engineer: Adam.Pittman Sos: Date: 02/23/18 Sp,: Code Input: TIA-222-G f,: R: Shaft and Appurtenance Seismic Design Loads Elevation ft) Weight Section lb) E Weight Appurt. lb) Vertical Force Dist. Lateral Seismic Force (lb) 3.29 2288 0 0.00 0 6.58 2220 0 0.00 0 9.88 2153 0 0.00 0 13.17 2087 0 0.00 1 16.46 2022 0 0.01 1 19.75 1958 0 0.01 1 23.04 1895 0 0.01 2 26.33 1833 0 0.01 2 29.63 1772 0 0.01 3 32.92 1712 0 0.02 3 36.21 1654 0 0.02 4 39.50 1596 0 0.02 4 42.79 1539 0 0.03 5 46.08 1483 0 0.03 5 49.38 1428 0 0.03 6 52.67 1374 0 0.04 6 55.96 1321 0 0.04 7 59.25 1270 0 0.04 7 62.54 1219 0 0.04 8 65.83 1169 0 0.05 8 69.13 1120 0 0.05 9 72.42 1072 0 0.05 9 75.71 1026 0 0.05 10 79.00 980 0 0.06 10 82.29 935 0 0.06 10 8S.S8 891 0 0.06 11 88.88 849 0 0.06 11 92.17 807 0 0.06 11 95.46 766 4725 0.06 12 98.75 726 0 0.07 12 1.60 SA / k,: 2.00 2.40 W,,: 0lb 0.08 W,: 47889lb 0.06 V5: 178 lb 0.01 Htz 1.5 Site Number: OAA724774 Site Name: Sanford FL, FL Engineer: Adam.Pittman Date: 02/23/18 Code Input: TIA-222-G Shaft Shear, Axial and Zero Tension, Cracking and Flexural Strengths Elevation ft) P„ 0.7 Ib) n 0.75 Ib) Mo Ib-ft) Mc, lb-ft) Wn 0=0.9 lb-ft) 3.29 3498094 220294 376897 744709 1548900 6.58 3392289 215323 369941 720045 9.88 3288056 210541 362986 695953 13.17 3185394 205953 356032 672423j1i"" 16.46 3084303 201565 349079 649446 19.75 2984785 197385 342127 627014 23.04 2886838 193422 335177 605117 26.33 2790462 189686 328227 583746 29.63 2695659 186191 321279 562891 32.92 2602426 182952 314332 542545 36.21 2510766 179961 307387 522697 39.50 2420677 177202 300444 503338 42.79 2332160 174708 293502 484460 46.08 2245214 172517 286561 466054 49.38 2159840 170675 279623 448110 52.67 2076037 165318 272687 430619 55.96 1993806 158770 265753 413573 59.25 1913147 152347 258821 396961 62.54 1834060 146049 251892 380776 65.83 1756544 139876 244966 365008 69.13 1680599 133829 238042 349649 72.42 1606226 127906 231122 334688 75.71 1533425 122109 224205 320119 79.00 1462196 116437 217292 305930 82.29 1392538 110890 210383 292114 85.58 1324452 105468 203478 278662 88.88 1257937 100172 196579 265565 92.17 1192994 95000 189684 252815 95.46 1129622 89954 182796 240402 98.75 1067823 85033 109601 162005 P per AC1318-05, 10.3.6.1 and 10.3.6.3, per AC1318-05, 9.3.2.2 V per AC1318-05, 11.4.2, per AC1318-05, 9.3.2.3 Unfactored Tower Loads & Deflections Site Number: Site Name: Engineer: Date: Code Input: Load Case: Dead Load + Wind Load OAA724774 Sanford FL, FL Adam.Pittman 02/23/18 TIA-222-G Load Case: Dead Load + Wind Load + Ice Load Elevation ft) Weight lb) Shear lb) MUteral lb-ft) MPe lb-ft) MTobt lb-ft) A in) A Degrees) Weight lb) Shear lb) MLa1e,ai lb-ft) MPe lb-ft) MToni lb-ft) e in) 0 Degrees) 0.0 47889 10395 815394 15841 831235 0.0 0.00 44237 752 41695 524 42219 0.0 0.00 3.3 45601 10239 781435 15793 797227 0.0 0.02 41949 728 39259 522 39780 0.0 0.00 6.6 43381 10085 747985 15653 763639 0.1 0.06 39730 704 36902 515 37417 0.0 0.00 9.9 41228 9934 715037 15430 730467 0.1 0.10 37577 680 34624 505 35129 0.0 0.00 13.2 39141 9786 682581 15130 697711 0.2 0.14 35490 657 32422 492 32914 0.0 0.01 16.5 37119 9641 650608 14760 665368 0.3 0.18 33468 634 30296 475 30772 0.0 0.01 19.8 35161 9498 619109 14326 633436 0.5 0.22 31510 612 28245 456 28701 0.0 0.01 23.0 33266 9358 588076 13836 601912 0.7 0.26 29614 590 26267 435 26702 0.0 0.01 26.3 31433 9220 557500 13294 570794 0.9 0.31 27781 568 24360 413 24772 0.0 0.01 296 29661 9086 527372 12708 540080 1.1 0.35 26009 547 22524 388 22912 0.1 0.02 32.9 27948 8952 497686 12084 509769 1.4 0.40 24296 526 20757 363 21120 0.1 0.02 36.2 26295 8817 468441 11427 479868 1.7 0.44 22643 505 19060 337 19397 0.1 0.02 39.5 24699 8681 439642 10743 450385 2.0 0.49 21047 484 17433 310 17743 0.1 0.02 42.8 23160 8546 411289 10039 421327 2.4 0.54 19509 462 15876 284 16160 0.1 0.02 46.1 21678 8410 383383 9319 392702 2.8 0.59 18026 441 14390 257 14647 0.1 0.03 49.4 20250 8274 355924 8589 364513 3.3 0.64 16598 419 12975 231 13206 0.1 0.03 52.7 18875 8139 328910 7855 336765 3.7 0.69 15224 398 11630 205 11835 0.2 0.03 56.0 17554 8005 302340 7121 309460 4.3 0.74 13902 376 10356 180 10536 0.2 0.03 59.3 16284 7872 276210 6392 282602 4.8 0.80 12633 355 9151 156 9308 0.2 0.03 62.5 15066 7739 250517 5674 256191 5.4 0.85 11414 334 8016 134 8150 0.2 0.04 65.8 13897 7609 225257 4971 230228 6.0 0.90 10245 313 6950 112 7063 0.3 0.04 69.1 12777 7479 200425 4288 204713 6.7 0.95 9125 293 5953 93 6046 0.3 0.04 72.4 11704 7351 176016 3628 179644 7.4 1.00 8053 272 5023 74 5098 0.3 0.04 75.7 10679 7226 152025 2997 155021 8.1 1.05 7027 252 4160 58 4218 0.3 0.04 79.0 9699 7102 128444 2397 130841 8.8 1.10 6047 232 3363 44 3407 0.4 0.04 82.3 8764 6980 105268 1833 107102 9.6 1.14 5112 213 2631 31 2662 0.4 0.04 85.6 7873 6860 82490 1309 83799 10.5 1.19 4221 193 1963 20 1983 0.4 0.04 88.9 7024 6743 60101 827 60928 11.3 1.22 3372 174 1358 11 1370 0.5 0.05 92.2 6217 6628 38095 390 38485 12.2 1.25 2566 156 815 5 820 0.5 0.05 95.5 5451 6516 16463 0 16463 13.0 1.27 1800 137 333 0 333 0.5 0.05 98.8 0 0 0 0 0 13.9 1.28 0 0 0 0 0 0.6 0.05 Unfactored Tower loads & Deflections Site Number: Site Name: Engineer: Date: Code Input: Load Case: Dead Load + Seismic Load OAA724774 Sanford FL, FL Adam.Pittman 02/23/18 TIA-222-G Load Case: Dead Load + Operational Wind Load Elevation ft) Weight lb) Shear Ib) Mtsteral lb-ft) MPe lb-ft) MTmm lb-ft) A in) 0 Degrees) Weight lb) Shear lb) Mtatual lb-ft) MPs lb-ft) MTotai lb-ft) A in) A Degrees) 0.0 47889 178 12124 204 12328 0.0 0.00 47889 3099 243086 4723 247809 0.0 0.00 3.3 45601 178 11540 203 11743 0.0 0.00 45601 3052 232962 4708 237670 0.0 0.01 6.6 43381 177 10955 201 11156 0.0 0.00 43381 3007 222990 4667 227657 0.0 0.02 9.9 41228 177 10372 198 10570 0.0 0.00 41228 2962 213168 4600 217768 0.0 0.03 13.2 39141 176 9791 193 9984 0.0 0.00 39141 2917 203492 4511 208002 0.1 0.04 16.5 37119 176 9211 188 9399 0.0 0.00 37119 2874 193960 4400 198360 0.1 0.05 19.8 35161 174 8636 182 8817 0.0 0.00 35161 2831 184570 4271 188841 0.1 0.07 23.0 33266 173 8065 174 8239 0.0 0.00 33266 2790 175318 4125 179443 0.2 0.08 26.3 31433 170 7500 167 7667 0.0 0.00 31433 2749 166203 3963 170166 0.3 0.09 29.6 29661 168 6943 158 7102 0.0 0.00 29661 2709 157221 3789 161009 0.3 0.10 32.9 27948 165 6396 150 6545 0.0 0.01 27948 2669 148371 3602 151973 0.4 0.12 36.2 26295 161 5859 140 5999 0.0 0.01 26295 2629 139652 3407 143059 0.5 0.13 39.5 24699 157 5335 131 5466 0.0 0.01 24699 2588 131067 3203 134269 0.6 0.15 42.8 23160 153 4825 121 4946 0.0 0.01 23160 2548 122614 2993 125607 0.7 0.16 46.1 21678 147 4332 112 4443 0.0 0.01 21678 2507 114295 2778 117073 0.8 0.18 49.4 20250 142 3856 102 3958 0.0 0.01 20250 2467 106108 2561 108669 1.0 0.19 52.7 18875 135 3401 92 3493 0.1 0.01 18875 2426 98055 2342 100397 1.1 0.21 56.0 17554 128 2967 83 3050 0.1 0.01 17554 2386 90134 2123 92257 1.3 0.22 59.3 16284 121 2556 74 2630 0.1 0.01 16284 2347 82344 1906 84250 1.4 0.24 62.5 15066 113 2171 65 2235 0.1 0.01 15066 2307 74684 1692 76376 1.6 0.25 65.8 13897 105 1812 56 1868 0.1 0.01 13897 2268 67154 1482 68636 1.8 0.27 69.1 12777 96 1481 48 1529 0.1 0.01 12777 2230 59751 1278 61029 2.0 0.28 72.4 11704 87 1181 40 1221 0.1 0.01 11704 2192 52474 1082 53556 2.2 0.30 75.7 10679 77 911 33 944 0.1 0.01 10679 2154 45322 893 46215 2.4 0.31 79.0 9699 67 675 26 700 0.1 0.01 9699 2117 38292 715 39007 2.6 0.33 82.3 8764 56 472 19 491 0.1 0.01 8764 2081 31383 547 31929 2.9 0.34 85.6 7873 46 304 14 318 0.1 0.01 7873 2045 24592 390 24982 3.1 0.35 88.9 7024 35 172 9 180 0.1 0.01 7024 2010 17917 246 18164 3.4 0.36 92.2 6217 23 77 4 81 0.1 0.01 6217 1976 11357 116 11473 3.6 0.37 95.5 5451 12 19 0 19 0.2 0.01 5451 1942 4908 0 4908 3.9 0.38 98.8 0 0 0 0 0 0.2 0.01 0 0 0 0 0 4.1 0.38 Load Combinations and Combined Strength Ratios LC = Strength Limit State Load Combinations (TIA-222-G 2.3.2) Site Number: OAA724774 LCl: 1.2 D + 1.6 W Site Name: Sanford FL, FL LC2: 0.9 D + 1.6 W Engineer: Adam.Pittman LC3: 1.2 D + 1.0 D, + 1.0 W; Date: 02/23/18 LC4: 1.2 D + 1.0 E Code Input: TIA-222-G LCS: 0.9 D + 1.0 E Factored Loads, Capacities and Interactions Elevation Axial Shear Flexural Vn On Wn Int. Eq. I Int. Eq. I Int. Eq. I Int. Eq. I Int. Eq. D D, W E Wi W E Wi LF 1.2 I 0.9 1.0 2.6 1.0 1.0 1.6 1.0 1.0 0.7 0.75 0.9 LC1 LC2 LC3 LC4 LC5 ft) (lb) (lb-ft) (lb) (lb-ft) 0.0 57467 43100 3652 16632 178 752 1329976 12328 42219 3498094 220294 1548900 0.86 0.86 0.03 0.02 0.01 3.3 54721 41041 3652 16382 178 728 1275564 11743 39780 3392289 215323 6.6 52058 39043 3652 16136 177 704 1221822 11156 37417 3288056 210541 9.9 49474 37106 3652 15895 177 680 1168748 10570 35129 3185394 205953 13.2 46970 35227 3652 15658 176 657 1116338 9984 32914 3084303 201565 16.5 44543 33407 3652 15425 176 634 1064589 9399 30772 2984785 197385 19.8 42194 31645 3652 15196 174 612 1013497 8817 28701 2886838 193422 23.0 39919 29940 3652 14972 173 590 963059 8239 26702 2790462 189686 26.3 37720 28290 3652 14752 170 568 913271 7667 24772 2695659 186191 29.6 35593 26695 3652 14537 168 547 864128 7102 22912 2602426 182952 32.9 33538 25153 3652 14323 165 526 815631 6545 21120 2510766 179961 36.2 31554 23665 3652 14107 161 505 767789 5999 19397 2420677 177202 39.5 29639 22229 3652 13890 157 484 720616 5466 17743 2332160 174708 42.8 27793 20844 3652 13673 153 462 674124 4946 16160 2245214 172517 46.1 26013 19510 3652 13456 147 441 628323 4443 14647 2159840 170675 49.4 24299 18225 3652 13239 142 419 583221 3958 13206 2076037 165318 52.7 22650 16988 3652 13023 135 398 538824 3493 11835 1993806 158770 56.0 21065 15799 3652 12808 128 376 495137 3050 10536 1913147 152347 59.3 19541 14656 3652 12594 121 355 452163 2630 9308 1834060 146049 62.5 18079 13559 3652 12383 113 334 409906 2235 8150 1756544 139876 65.8 16676 12507 3652 12174 105 313 368365 1868 7063 1680599 133829 69.1 15332 11499 3652 11967 96 293 327540 1529 6046 1606226 127906 72.4 14045 10534 3652 11762 87 272 287431 1221 5098 1533425 122109 75.7 12815 9611 3652 11561 77 252 248034 944 4218 1462196 116437 79.0 11639 8729 3652 11363 67 232 209346 700 3407 1392538 110890 82.3 10517 7888 3652 11168 56 213 171363 491 2662 1324452 105468 85.6 9447 7086 3652 10976 46 193 134078 318 1983 1257937 100172 88.9 8429 6322 3652 10789 35 174 97485 180 1370 1192994 95000 92.2 7461 5596 3652 10605 23 156 61575 81 820 1129622 89954 95.5 6542 4906 3652 10425 12 137 26340 19 333 1 1067823 1 85033 Base P V M 57.47 16.63 1329.98Reactions: kip kip k-ft Max Usages: 0.86 1 0.86 1 0.03 1 0.02 1 0.01 Site Name: Sanford FL, FL Site Number: 412281 Engineer: Adam.Pittman Engineering Number: OAA724774 Date: 02/23/18 Design Base Loads (Factored) - Analysis per TIA-222-G Standards Analyze or Design a Foundation? Analyze Moment (M): 1330.0 k-ft Shear/Leg(V): 16.6 k Axial Load (P): 57.5 k Uplift/Leg (U): 0.0 k Tower Type (GT / SST / MP): CMP Diameter of Caisson (d): Caisson Embedment (L-h): Caisson Height Above Ground (h): Depth Below Ground Surface to Water Table (w): Unit Weight of Concrete: Unit Weight of Water: Tension Skin Friction/Compression Skin Friction: Pullout Angle: Soil Mechanical Properties Depth (ft) Ysod Top Bottom (pcf) 0.0 S.0 108 5.0 27.5 108 Program Last Updated: 511312014 American Tower Corporation S.O ft 26.5,ft 0.0 ft r - 12.7' ft 150.OI pcf 62.4 1 pcf 0.55 30.O degrees I Engineer Notes 1 Cohesion Ultimate Skin Ultimate Bearing psf) (degree) Friction (psf) Pressure (psf) 0 0 0 0 0 32 800 18000 I Required Embedment: Volume of Concrete: Weight of Concrete (Buoyancy Effect Considered): Average Soil Unit Weight: Skin Friction Resistance: Compressive Bearing Resistance: Pullout Weight (Minus Concrete Weight): Nominal Uplift Capacity per Leg (J ): Nominal Compressive Capacity per Leg (,P ): P.: Tu/SST.: PAY.: Total Lateral Resistance: Inflection Point (Below Ground Surface): Design Overturning Moment At Inflection Point (MD): Nominal Moment Capacity (CM ): MD/W : 5: 18.8 ft - OK, Caisson Embedment Satisfactory 526.2 ft' = 19.5 yd3 61.8 k 74.7 pcf 271.7 k 357.4 k 724.4 k 158.4 k 471.8 k 84.5 k 0.00 Result: OK 0.18 Result: OK 1290.3 k 18.1 ft 1631.2 k-ft 4746.8 k-ft 0.34 Result: OK 0.75 VERIZON SITE #: 132046 VERIZON SITE NAME: SANFORD PLAZA ATC SITE #: ATC SITE NAME: 412281 SANFORD FL PROJECT DESCRIPTION: EQUIPMENT INSTALLATION TOWER TYPE: JURISDICTION: PRESENT OCCUPANCY TYPE: CURRENT ZONING: PARCEL M 98.8FT MONOPOLE CITY OF SANFORD TELECOMMUNICATIONS FACILITY UNKNOWN 01-20-30-509-0000-2600 I PROJECT INFORMATION I LATITUDE: 28.77138° ' LONGITUDE:-81.27583° GROUND ELEVATION: 40'i (AMSL) - INFORMATION PROVIDED BY ATC TOWER COORDINATES SITE DEVELOPER/APPLICANT: verizonl/ 4700 EXCHANGE COURT, SUITE 100 BOCA RATON, FL 33431 VERIZON SITE ID: 132046 VERIZON SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD, FL 32773 SEMINOLE COUNTY) Q LESSEE: P„L.xSlarage NAME: VERIZON WIRELESS ADDRESS: 4700 EXCHANGE COURT, SUITE 100 C•1v Oca C CITY, STATE, ZIP: BOCA RATON, FL 33431 UiPA A.u P,Ir, s,.v:' SJ: IrJ F CONTACT: FLORIDA OFFICE r.a7d Rum ST c; PHONE: UNKNOWN Q TOWER OWNER: Q ® tam.t Sot cty 7 a15_r1d1d :'r;OAI NAME: AMERICAN TOWER CORPORATION ADDRESS: 900 CIRCLE 75 PARKWAY, STE 300 CITY, STATE, ZIP: ATLANTA, GA 30339 CONTACT: JAMES MCINTURF S:nl-Ld Be1ury SuIIay PHONE: (407) 488-0524 0,rtt.; Lulu A Q CIVIL ENGINEER: NAME: TOWER ENGINEERING PROFESSIONALS ADDRESS: 326 TRYON ROAD 9 CITY, STATE, ZIP: RALEIGH, NC 27603 CONTACT: JUSTIN J. COSGROGROVE, P.E. I 3tITc PHONE: (919) 661-6351 ELECTRICAL ENGINEER: NAME: TOWER ENGINEERING PROFESSIONALS ADDRESS: 326 TRYON ROAD CITY, STATE, ZIP: RALEIGH, NC 27603 1 HaTx 8G1rt1_tory CONTACT: JUSTIN J. COSGROVE, P.E. PHONE: (919) 661-6351 PROPERTY OWNER: As shown on plan, ok for antenna upgrade on NAME: SANFORD PLAZA INC OF DELTONA existing 98.8 foot monopole communication ;0 ADDRESS: PO BOX 543 CITY, S ATE, ZIP: SANFORD, FL 32772 tower at 2931 Orlando Drive. The Orlando CONTACT: UNKNOWN PHONE: UNKNOWN Sanford -International Airport must be contacted if any cranes are used. LOCATION MAP CONTACT INFORMATIONMN711 ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING: 1. 2017 FLORIDA BUILDING CODE, 3. ANSIMA-222-G-2-2009 6TH EDITION 4. 2014 N.E.C. 2. LOCAL BUILDING CODE S. CITYICOUNTY ORDINANCES C-ODE-COMPLIANCE :j THE STRUCTURAL ANALYSIS REPORT BY AMERICAN TOWER ACCORDANCE WITH T HEB2017R FLORIDA BUILDINGPERFORMED6TH EDITION, BASED UPON: 1. WIND SPEED (ULTIMATE 3-SECOND GUST) - 139 MPH 2. WIND SPEED (NOMINAL }SECOND GUST) = 110 MPH 3. EXPOSURE CATEGORY = B RISK CATEGORY 4DESIGN CRITERIA UTILITIES: POWER COMPANY: FLORIDA POWER & LIGHT CONTACT: CUSTOMER SERVICE PHONE: (800) 375-2434 METER # NEAR SITE: UNKNOWN TELEPHONE COMPANY: AT&T CONTACT: CUSTOMER SERVICE PHONE: 866 731-2653 PHONE # NEAR SITE: 407 323-5376 PEDESTAL # NEAR SITE: 9105A-920 SITE OWNER: AMERICANTOWER* C O A O A• T 1 O N 900 CIRCLE 75 PARKWAY, STE 300 ATLANTA, GA 30339 ATC #: 412281 ATC SITE NAME: SANFORD FL THE PURPOSE OF THIS PROJECT IS AS FOLLOWS: TOWER SCOPE OF WORK: REMOVE ( 3) BIAS TEE .INSTALL (2) HYBRID REMOVE ( 3) ANTENNAS •INSTALL (9) RADIOS REMOVE ( 5) COAX .INSTALL (1) COVP REPLACE ( 1) 6101 CABINET .INSTALL (3) PCS COMBINERS INSTALL ( 1) CHARLES CUBE • INSTALL (3) RADIOS (GROUND) PROJECT SCOPE OF WORK THE LESSEE ISSUED SCOPE OF WORK IS AS FOLLOWS: 1. ADD PCS LTE SERVICE. 2. REMOVE (3) 700 LTE PLACE HOLDER ANTENNAS. 3. MOVE EXISTING HEX -PORT ANTENNAS TO HAVE SEPERATION OF 2.5 FEET ON CENTER AS SHOWN IN THE PLUMBING DIAGRAM. 4. ADD (9) TOWER -MOUNTED RADIO 2212 (3 FOR 700 LTE AND 6 FOR PCS LTE). 5. ADD (2) HYBRID CABLES. 6. REMOVE (5) COAX. 7. ADD (3) TOWER -MOUNTED COMMSCOPE TD.PCS-1 S343485 (TWIN) IN BAND COMBINERS. E. REMOVE (3) BIAS-T IF IT HELPS WITH RENTISTRUCTURE AND RADIO 2212 RET PORTS. 9. ALL LTE BANDS SHOULD BE CABAPLE OF 4TX14RX. I CODE COMPLIANCE I ISHEETI DESCRIPTION I REV 1 22C PROPOSED ANTENNA LAYOUT 1 C35 FINAL ANTENNA & CABLE SCHEDULE 1 E2 EQUIPMENT SERVICE ONE -LINE DIAGRAM 1 E3 PANELBOARD SCHEDULES 1 131 1 GROUNDING DETAILS 1 INDEX OF SHEETS PLANS PREPARED BY: TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-5263 OFFICE: ( 919) 661-6351 www. tepgroup.net FL COA # 30978 I 05-30- 18 CONSTRUCTION O 1 04- 1 0- 18 PRELIMINARY REVI DATE I ISSUED FOR: I DRAWN BY: 5135 1 CHECKED BY: C511 1 SEAL: N 83902 1r anolte D STATE OF P io tc F OR10P ONAL I I I II I II 51fay 30, 2018 SHEET NUMBER: REVISION: T- 1 1 TEP#: 84603.94199 PROJECT NOTES: 1. ALL REFERENCES TO THE OWNER AND/OR LESSEE IN THESE DOCUMENTS SHALL BE CONSIDERED VERIZON OR ITS DESIGNATED REPRESENTATIVE. 2 WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE 2017 FLORIDA BUILDING CODE (6TH EDITION). 3 UNLESS SHOWN OR NOTED OTHERWISE ON THE CONTRACT DRAWINGS, OR IN THE SPECIFICATIONS, THE FOLLOWING NOTES SHALL APPLY TO THE MATERIALS LISTED HEREIN, AND TO THE PROCEDURES TO BE USED ON THIS PROJECT 4. ALL HARDWARE ASSEMBLY MANUFACTURER'S INSTRUCTIONS SHALL BE FOLLOWED EXACTLY AND SHALL SUPERSEDE ANY CONFLICTING NOTES ENCLOSED HEREIN. 5. ALL DIMENSIONS, ELEVATIONS, AND EXISTING CONDITIONS SHOWN ON THE DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO BEGINNING ANY MATERIALS ORDERING, FABRICATION OR CONSTRUCTION WORK ON THIS PROJECT. CONTRACTOR SHALL NOT SCALE CONTRACT DRAWINGS IN LIEU OF FIELD VERIFICATIONS. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER AND THE OWNER'S ENGINEER. THE DISCREPANCIES MUST BE RESOLVED BEFORE THE CONTRACTOR IS TO PROCEED WITH THE WORK. THE CONTRACT DOCUMENTS DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIOUES, SEQUENCES, AND PROCEDURES. OBSERVATION VISITS TO THE SITE BY THE OWNER AND/OR THE ENGINEER SHALL NOT INCLUDE INSPECTION OF THE PROTECTIVE MEASURES OR THE PROCEDURES 6. ALL MATERIALS AND EOUIPMENT FURNISHED SHALL BE NEW AND OF GOOD QUALITY, FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. ANY AND ALL SUBSTITUTIONS MUST BE PROPERLY APPROVED AND AUTHORIZED IN WRITING BY THE OWNER AND ENGINEER PRIOR TO INSTALLATION. THE CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND DUALITY OF THE MATERIALS AND EOUIPMENT BEING SUBSTITUTED. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT THIS PROJECT AND RELATED WORK COMPLIES WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL SAFETY CODES AND REGULATIONS GOVERNING THIS WORK. 8. ACCESS TO THE PROPOSED WORK SITE MAY BE RESTRICTED. THE CONTRACTOR SHALL COORDINATE INTENDED CONSTRUCTION ACTIVITY, INCLUDING WORK SCHEDULE AND MATERIALS ACCESS, WITH THE RESIDENT LEASING AGENT FOR APPROVAL. 9. ALL PERMITS THAT MUST BE OBTAINED ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR WILL BE RESPONSIBLE FOR ABIDING BY ALL CONDITIONS AND REOUIREMENTS OF THE PERMITS. 10 IF APPLICABLE, ALL CONCRETE WORK SHALL COMPLY TO LOCAL CODES AND THE ACI 318-11, "BUILDING REQUIREMENTS FOR STRUCTURAL CONCRETE". 11. ALL TOWER DIMENSIONS SHALL BE VERIFIED WITH THE PLANS LATEST REVISION) PRIOR TO COMMENCING CONSTRUCTION. NOTIFY THE ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE DISCOVERED. A DESIGNATED RESPONSIBLE EMPLOYEE SHALL BE AVAILABLE FOR CONTACT BY GOVERNING AGENCY INSPECTORS. 12. ALL TOWER MODIFICATION WORK SHALL BE IN ACCORDANCE WITH TIA-1019—A STANDARD FOR INSTALLATION, ALTERATION AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS. PLANS PREPARED FOR: verizonv 4700 EXCHANGE COURT, SUITE 100 BOCA RATON, FL 33431 PROJECT INFORMATION: VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD, FL 32773 SEMINOLE COUNTY) PLANS PREPARED BY: so TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup.net FL COA # 30978 SEAL: ` IIIIII110 / C No 3902 Spits STATE OF 1O.c SS/ONAL E? I/ 1 1I I II, 1fay 30, 2018 1 05-30-18 CON5TRUCTION O 04-10- 18 PRELIMINARY REV DATE ISSUED FOR: DRAWN BY: 5E35 I CHECKED BY: C5N SHEET TITLE: PROJECT NOTES SHEET NUMBER: REVISION: N-1 1 TEPN: 84GO3.94 199 NOTE: COMPOUND DETAIL TAKEN FROM INFORMATION PROVIDED BY ATC. CONTRACTOR TO VERIFY ALL EXISTING INFORMATION IS AS INDICATED ON SITE PLAN. CONTRACTOR IS TO ESTABLISH THE EXISTENCE AND LOCATION OF ALL EXISTING OVERHEAD AND UNDERGROUND UTILITIES. IMMEDIATELY NOTIFY THE CONSTRUCTION MANAGER OF ANY DISCREPANCIES. EXISTING LESSEE 250 GALLON PROPANE TANK x x x O EXISTING LESSEE 18'-6"x8'—O" CONCRETE EOUIPMENT PAD EXISTING LESSEE EOUIPMENT RACK TYP) x 8 EXISTING MONOPOLE 2 TOWER. SEE SHEET 1 C-2 FOR ELEVATION. x x x x x EXISTING CONCRETE EOUIPMENT PAD BY EXISTING EOUIPMENT RACK OTHERS BY OTHERS (TYP) VZW EQUIPMENT NOTES: OICE BRIDGE (TYP) O7 TELCO CABINET O2 OVP (TYP) O8 (3) PROPOSED RADIO 2212 INSTALLED ON ICE BRIDGE OCHARLES CUBE TO REPLACEEXISTINGLTE6101CABINET O4 4.OB BTS CABINET OEMBRE BATTERY CABINET O6 30 KW LP GENERATOR WITH BELLY TANK COMPOUND PLAN SCALE: 1" = 10' STING 12'-0" WIDE CESS GATE EXISTING CHAIN -LINK FENCED COMPOUND X EXISTING GRAVEL WITHIN COMPOUND 0 10 20 iiiil SCALE IN FEET PLANS PREPARED FOR: verizonv 4700 EXCHANGE COURT, SUITE 100 BOCA RATON, FL 33431 PROJECT INFORMATION: VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD, FL 32773 SEMINOLE COUNTY) PLANS PREPARED BY: WE TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup.net FL COA # 30978 SEAL: IIIIIIII/I// C No 3902 a STATE OF ar u io F` ' c OR10P g,\ A \\ II i 11\? May 30, 2018 I 05-30- 18 CON5TRUCTION 0 04-10-18 PRELIMINARY REV DATE ISSUED FOR: DRAWN BY: 565 1 CHECKED BY: C5N SHEET TITLE: COMPOUND PLAN SHEET NUMBER: REVISION: c - 1 1 TEP#: 84G03.94 1 99 PLANS PREPARED FOR: NOTES: 1. TOWER ELEVATION IS FOR SCHEMATIC PURPOSES ONLY. TEP DID NOT CONFIRM EXISTING SITE CONDITIONS INCLUDING, BUT NOT LIMITED TO. ANTENNA HEIGHTS. ANTENNA AZIMUTHS, AND MOUNT CONFIGURATIONS. 2. TEP DID NOT ANALYZE TOWER TO DETERMINE ADEOUATE STRUCTURAL CAPACITY FOR ANY LESSEE LOADING. 3. FAA REGISTERED HEIGHT WITH APPURTENANCES IS 110'-0- (150'-O"AMSL) 100'-0"f LESSEE ANTENNAS 98'-10"t T/TOWER 0'-0" (REFERENCE) 7/ CONCRETE TOWER ELEVATION SCALE: 1" = 20' EXISTING LESSEE ANTENNA (TYP OF 6). SEE SHEETS C-3A THROUGH C-3D FOR DETAILS. 5) 1%7 COAX TO BE REMOVED AND (2) 1%' HYBRIFLEX TO BE ROUTED PER SPECIFICATION OF PASSING STRUCTURAL ANALYSIS EXISTING MONOPOLE TOWER 0 20 40 SCALE IN FEET verizon-1 4700 EXCHANGE COURT, SUITE 100 BOCA RATON, FL 33431 PROJECT INFORMATION: VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD, FL 32773 SEMINOLE COUNTY) PLANS PREPARED BY: TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup.net FL COA # 30978 SEAL: N 83902 STATE OF tea\ 0' 'c OR10P N, i'/%P'/ OINA 11\? G\\ III ,11ay 30, 2018 1 05-30-18 C0145TPUCTION O 04- 10- 18 PPELIMINAPY REV DATE ISSUED FOR: DRAWN BY: 565 1 CHECKED BY: CSN SHEET TITLE: TOWER ELEVATION SHEET NUMBER: REVISION: C-2 1 TEP#: 54GO3 94 199 NOTE: TEP HAS NOT VERIFIED ANY EXISTING ANTENNA CONFIGURATION OR MOUNT CONFIGURATION. CONTRACTOR TO VERIFY MOUNT CONFIGURATION HAS SUFFI( EOUIPMENT (I E. CLEARANCES, MOUNT PIPE OF SUFFICIENT Lf EXISTING ANTENNA LAYOUT @ 100'-0" SCALE: N.T.S. EXISTING ANTEL ANTENNA TO BE REMOVED (TYP OF 3). SEE SHEETS C-3B THROUGH C-31) FOR DETAILS. EXISTING COMMSCOPE BIAS—T TO BE REMOVED (TYP OF 3) A x^ EXISTING COMMSCOPE CBC721-DF-2X DIPLEXER TO REMAIN (TYP OF 3) EXISTING ERICSSON RRUS-32 TO REMAIN (TYP OF 3) EXISTING JMA WIRELESS ANTENNA TO REMAIN (TYP OF 6). SEE SHEETS C-3B THROUGH C-3B FOR DETAILS. EXISTING RAYCAP COVP TO REMAIN PLANS PREPARED FOR: verizon,l 4700 EXCHANGE COURT, SUITE 100 BOCA RATON, FL 33431 PROJECT INFORMATION: VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD, FL 32773 SEMINOLE COUNTY) PLANS PREPARED BY: l\\ TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup.net FL COA # 30978 SEAL: N 83902 a STATE OF It F ORIOI"' IN i i/s//1o1NAIII 11\ G\\ ltay 30, 2018 1 05-30- 18 C0145TRUCTION 0 04-10-15 PRELIMINARY REV DATE ISSUED FOR: DRAWN BY: 555 CHECKED BY: C5N SHEET TITLE: EXISTING ANTENNA LAYOUT SHEET NUMBER: REVISION: 3A 1 TEP#: 84GO3.94199 PLANS PREPARED FOR: EXISTING ANTENNA 8 CABLE SCHEDULE MANUFACTURER RAD CABLE AZIMUTH CABLE MECH. ELEC. DIPLEXERS/RRUS/BIAS-T J-BOX POS. SECTOR USE MODEL #) CENTER SIZE TN) LENGTH D-TILT D-TILT MODEL #] TOWER) 1 ALPHA 2100 C7COCAP- RO00JMAL656-VRO Cj O 100ESS'-0"t COAX 1p• 140't 1) COMMSCOPEXER 1) ERICSSON RRUS 32 W/ SOLAR SHIELD] 1 COMMSCOPE BIAS -TEE ATSBT-TOP-FM-4G] 1) RAYCAP RRFDC-3315-PF-48 2 ALPHA ANTEL BXA-70063/6CF L p 100'-0"t 10' 3 ALPHA 700 1900 JMA WIRELESS C7COCAP-FRO-656-VRO 100'-0"t 10' 4 BETA 2100 C7COCAP- ROJMA L656-VRO 100'- 0"t 130' 1) [ CBC721-DF D2XjEXER 1) ERICSSON RRUS 32 W/ SOLAR SHIELD] 5BETAANTEL BXA- 70063/6CF p 100'-0"t 130' 1) 1%" HYBRIFLEX EE 1 TOBMSTCOOPPEFMIA4G] 6BETA17900C7COCAP- ROJMA L656- VRO ESS 100'- 0" t 130. 7 GAMMA 2100 C7COCAP- RO00 JMA L656-VRO 1O0ESS'-0' 250' 1) [CBCM72i- DF DZXjEXER 1) ERICSSON RRUS 32 W/ SOLAR SHIELD] 1 COMMSCOPE BIAS -TEE ATSBT-TOP- FM-4G] 8 GAMMA ANTEL BXA- 70063/ 6CF 100'-0"t 250' 9 GAMMA 700 1900 JMA WIRELESS C7COCAP-FRO- 656-VRO lO0'-0" t 250' NOTE - EXISTING EOUIPMENT/ANTENNA TO BE REMOVED NOTE - (5) 1%_ COAX TO BE REMOVED NOTE - CONTRACTOR TO REFERENCE LESSEE ISSUED RFDS FOR MECHANICAL AND ELECTRICAL DOWNTILTS EXISTING ANTENNA SCHEDULE SCALE: N. T.S. verizon-1 4700 EXCHANGE COURT, SUITE 100 BOCA RATON. FL 33431 PROJECT INFORMATION: VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD, FL 32773 SEMINOLE COUNTY) PLANS PREPARED BY: TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup. net FL COA # 30978 SEAL: C 83902 1p STATE OF Q: o' ORIOP sNA// IO1111 G\\ II 1 14fay 30, 2018 1 05-30- 18 C0145TRUCTION O 04- 10- 18 PRELIMINARY REV DATE ISSUED FOR: DRAWN BY: 5135 1 CHECKED BY: C51-1 SHEET TITLE: EXISTING ANTENNA SCHEDULE SHEET NUMBER: REVISION: C- 3B 1 TEPN: 84GO3.94 195 NOTES: 1. TEP HAS NOT VERIFIED ANY EXISTING ANTENNA CONFIGURATION OR MOUNT CONFIGURATION. CONTRACTOR TO VERIFY MOUNT CONFIGURATION HAS SUFFICIENT SPACE FOR PROPOSED LESSEE EOUIPMENT (I.E. CLEARANCES, MOUNT PIPE OF SUFFICIENT LENGTH, ETC.). 2 CONTRACTOR TO VERIFY PROPOSED LOADING WITH TOWER STRUCTURAL ANALYSIS PRIOR TO CONSTRUCTION. PROPOSED ANTENNA LAYOUT @ 100'-0" SCALE: N.T.S. PROPOSED LESSEE ERICSSON RADIO 2212 B2/B66A TYP OF 6) PROPOSED LESSEE RAYCAP COUP. SEE SHEET C-3D FOR DETAILS. PROPOSED LESSEE ERICSSON RADIO 2212 B13/85 TYP OF 3) PROPOSED LESSEE COMMSCOPE TD-PCS-1-B3-B4B5 COMBINER TYP OF 3) PLANS PREPARED FOR: verizonNI 4700 EXCHANGE COURT, SUITE 100 BOCA RATON. FL 33431 PROJECT INFORMATION: VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD, FL 32773 SEMINOLE COUNTY) PLANS PREPARED BY: I TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup.net FL COA # 30978 SEAL: F o N 83902 fpo1M STATE OF Q\ OR1OP I/ lilt T y30,2018 1 05-30- 18 COtJ5TRUCTION O 04- 1 O- 18 PRELIMINARY REV DATE ISSUED FOR: DRAWN BY: 5135 CHECKED BY: C5N SHEET TITLE: PROPOSED ANTENNA LAYOUT SHEET NUMBER: REVISION: C-3C 1 TEP#: 64G03 94 199 PLANS PREPARED FOR: IN II FINAL ANTENNA & CABLE SCHEDULE II MANUFACTURER RAD CABLE AZIMUTH CABLE MECH. ELEC. TMA/RRU/ DIPLEXER J-BOX POS. SECTOR USE MODEL #) CENTER SIZE TN) LENGTH D-TILT D-TILT MODEL #] TOWER) 1 ALPHA 700 SS 0 100'-0"t 10' 1) COMMSCOPE DIPLEXER [CBC721-DF-2X] C7COCAP-FROL VRO 1) ERICSSON [RRUS 32 W/ SOLAR SHIELD] 2 ALPHA 0 too'-0"t 10, 1) COMMSCOPE COMBINER [TD-PCS-1-B3-B4B5] 1) ERICSSON [RADIO 2212 B13/B51 3 ALPHA 1900 JMA WIRELESS C7COCAP-FRO-656 VRO 700 0 100-0"t 6) 1 700 COAX 10' 2) ERICSSON [RADIO 2212 B2/B66A] 4 BETA JMA WIRELESS 0 100'-0"t 130' 1) COMMSCOPE DIPLEXER [CBC721-DF-2X] 2100 C7COCAP-FRO-656 VRO 1) 1%- HYBRIFLEX 00140't 1) ERICSSON [RRUS 32 W/ SOLAR SHIELD] 1) COMMSCOPE COMBINER [TD-PCS-1-B3-B485] 1) RAYCAP RRFDC-3315-PF-48 5 BETA 0 1DO'-0"t 130' 1) ERICSSON [RADIO 2212 B13/B5] RAYCAP RCMDC) 6627-PF-48 6 BETA 700 1900 JMA WIRELESS C7COCAP-FRO-656 VRO rL 0 100'-0"t B 1RIFLExHY 130' 2) ERICSSON [RADIO 2212 82/666A] 7 GAMMA 700 JMA WIRELESS i 0 100'-0"t 250' 1) COMMSCOPE DIPLEXER [CBC721-DF-2X] 2100 C7COCAP-FRO-656 VRO 1) ERICSSON [RRUS 32 W/ SOLAR SHIELD] 8 GAMMA CL 0 100'-0"t 250' 1) COMMSCOPE COMBINER [TD-PCS-1-B3-B4B5] 1) ERICSSON [RADIO 2212 B13/B5] 9 GAMMA 1900 JMA WIRELESS C7COCAP-FRO-656 VRO 700 CL 0 100-0"t 250' 2) ERICSSON [RADIO 2212 82/B66A] NOTE - CONTRACTOR TO REFERENCE LESSEE ISSUED RFDS FOR MECHANICAL AND ELECTRICAL DOWNTILTS NOTE - CONTRACTOR TO VERIFY CABLE LENGTH(S) PRIOR TO CONSTRUCTION FINAL ANTENNA & CABLE SCHEDULE SCALE: N.T.S verizonN' 4700 EXCHANGE COURT, SUITE 100 BOCA RATON, FL 33431 PROJECT INFORMATION: VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD, FL 32773 SEMINOLE COUNTY) PLANS PREPARED BY: I TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup.net FL COA # 30978 SEAL: `, dill/o/ C Sa V/, p N 83902 Smile STATE OF Q iO c` F OR10P ONAL 111% -11ay 30, 2018 1 05-30-18 C0145TPUCTION O 04-10-18 PRELIMINARY REV DATE ISSUED FOR: DRAWN BY: 555 1 CHECKED BY: C5N SHEET TITLE: FINAL ANTENNA CABLE SCHEDULE SHEET NUMBER: REVISION: C-3D 1 TE P #: 84 GO3.94 199 RRU POLERRUs MOUNTING BRACKET (TYP) RRU (REFER TO Q REDS FOR AMOUNT PER SECTOR) DIPLEXER MAKE AND MODEL DIPLEXER MAKE: COMMSCOPE DIPLEXER MODEL. TD-PCS-1-B3-B4B5 DIMENSIONS, HxWxD: 18.3'xl4.4'x3.5' WEIGHT (W/0 MOUNT. HARDWARE):34.8 lbs COVP MAKE AND MODEL COVP MAKE: RAYCAP COVP MODEL: RCMDC-6627-PF-48 DIMENSIONS, HxWxD 29.5'x165'x12.6' WEIGHT: 43.0 lbs RADIO MAKE AND MODEL RADIO MAKE: ERICSSON RADIO MODEL: RADIO 2212 B13/B5 SUN SHIELD MATERIAL: UPVC SUN SHIELD COLOR: LIGHT GRAY DIMENSIONS, HxWxD: 26.7'xl2.1'x6.7 PLANS PREPARED FOR: verizon w/ 4700 EXCHANGE COURT, SUITE 100 BOCA RATON. FL 33431 WEIGHT: 47.4 lbs PROJECT INFORMATION: ANTENNA' Q Q l I VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2521 S ORL NDODRIVE r- Z 773 SEMINOLE COUNTY) i PLANS PREPARED BY: i A 1 MOUNT PIPE MOUNTING BRACKET SUPPLIED W/ ANTENNA (TYP) TOWER ENGINEERING PROFESSIONALS ANTENNA 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup.netMOUNTINGDETAILSEQUIPMENTDETAILSEQUIPMENTDETAILSEQUIPMENTDETAILS SCALE: N.T.S. SCALE. N.T.S. SCALE: N TS. SCALE: N.T.S FLCOA#30978 RADIO MAKE AND MODEL SEAL: RADIO MAKE: ERICSSON RADIO MODEL- RADIO 2212 B2/B66A SUN SHIELD MATERIAL: UPVC SUN SHIELD COLOR: LIGHT GRAY DIMENSIONS, HxWxD: 26.7'x12.1'x6.7' WEIGHT: 47.4 lbs C n N9D2 Sj STATE OF Q\ OR% G\\ ONAL EN11lIII %\0 ; 1fay 30, 2018 I I 05-30-18 C0145TRUCTION O 04-10-18 PRELIMINARY REV DATE ISSUED FOR: DRAWN BY: 5B5 CHECKED BY: C5N t i SHEET TITLE: EQUIPMENT DETAILS SHEET NUMBER: C-4 REVISION: 1EQUIPMENTDETAILS SCALE: N.T.S. TEPN: 84603.94 195 NOTES: 1. CONTRACTOR TO VERIFY SUFFICIENT SPACE FOR PROPOSED CABINET PRIOR TO CONSTRUCTION. 2. CONTRACTOR TO INSTALL CABINET PER MANUFACTURER SPECIFICATIONS. 2) QUARTER TURN! 216 STYLE PADLOCKABU REMOVABLE REAR PANEI 4) QUARTER TURN! 216 STYLE 2) QUARTER TURN! 216 STYLE PADLOCKABLE REMOVABLE REAR PANE( 2) QUARTER TURN! 216 STYLE 2) EXTERNAL GROUND LUGS OVERHEAT THERMOSTAT CONDITIONER 13RU, 23' HORIZONTAL RACK MOUNTING WITH EIA HOLE SPACING 3RU, 23- VERTICAL RACK MOUNTING 15RU,19' HORIZONTAL RACK MOUNTING WITH EIA HOLE SPACING BATTERY BREAKER ALARM TERMINAL BLOCKS OVERHEAT THERMOSTAT BATTERY BREAKERS 2) BATTERY TRAYS CABINET DETAILS SCALE: N.T.S. DOOR ALARM AND AC CUTOFF SWITCHES GFCI ALARM TERMINAL PANEL 3PT LATCH 216 STYLE PADLOCKABLE DOOR HANDLE 2) 2X8 POSITION GROUND BARS WIND LATCH 3PT LATCH 216 STYLE PADLOCKABLE SWING HANDLE I 1 WIND LATCH DOOR ALARM 4) LIFTING BRACKETS SOLAR SHIELD 01 EQUIPMENT COMPARTMENT BATTERY COMPARTMENT PLANS PREPARED FOR: verizon 4700 EXCHANGE COURT, SUITE 100 BOCA RATON. FL 33431 PROJECT INFORMATION: VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD, FL 32773 SEMINOLE COUNTY) PLANS PREPARED BY: All TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup.net FL COA # 30978 SEAL: C o N 83902 p STATE OF p tc, c ORIOP ONAL I II m`? 11ay 30, 2018 1 05-30-18 C0145TRUCTION O 04-10-15 PRELIMINARY REV DATE ISSUED FOR: DRAWN BY: 565 1 CHECKED BY: C51.1 SHEET TITLE: CABINET DETAILS SHEET NUMBER: REVISIO; 541.03 C-5 TEPN: .94 199 SCOPE: 1. PROVIDE LABOR, MATERIALS. INSPECTION, AND TESTING TO PROVIDE CODE COMPLIANCE FOR ELECTRIC. TELEPHONE, AND GROUNDING/LIGHTNING SYSTEMS. CODES: 1. THE INSTALLATION SHALL COMPLY WITH APPLICABLE LAWS AND CODES. THESE INCLUDE BUT ARE NOT LIMITED TO THE LATEST ADOPTED EDITIONS OF: A. THE NATIONAL ELECTRICAL SAFETY CODE D. LOCAL AND STATE AMENDMENTS B. THE NATIONAL ELECTRIC CODE - NFPA-70 E. THE INTERNATIONAL ELECTRIC CODE - C. REGULATIONS OF THE SERVING UTILITY COMPANY IEC (WHERE APPLICABLE) 2. PERMITS REQUIRED SHALL BE OBTAINED BY THE CONTRACTOR. 3. AFTER COMPLETION AND FINAL INSPECTION OF THE WORK, THE OWNER SHALL BE FURNISHED A CERTIFICATE OF COMPLETION AND APPROVAL. TESTING: 1. UPON COMPLETION OF THE INSTALLATION, OPERATE AND ADJUST THE EQUIPMENT AND SYSTEMS TO MEET SPECIFIED PERFORMANCE REQUIREMENTS. THE TESTING SHALL BE DONE BY QUALIFIED PERSONNEL. GUARANTEE: 1. IN ADDITION TO THE GUARANTEE OF THE EQUIPMENT BY THE MANUFACTURER, EACH PIECE OF EQUIPMENT SPECIFIED HEREIN SHALL ALSO BE GUARANTEED FOR DEFECTS OF MATERIAL OR WORKMANSHIP OCCURRING DURING A PERIOD OF ONE (1) YEAR FROM FINAL ACCEPTANCE OF THE WORK BY THE OWNER AND WITHOUT EXPENSE TO THE OWNER 2. THE WARRANTEE CERTIFICATES & GUARANTEES FURNISHED BY THE MANUFACTURERS SHALL BE TURNED OVER TO THE OWNER. UTILITY CO-ORDINATION: 1. CONTRACTOR SHALL COORDINATE WORK WITH THE POWER AND TELEPHONE COMPANIES AND SHALL COMPLY WITH THE SERVICE REQUIREMENTS OF EACH UTILITY COMPANY. EXAMINATION OF SITE: 1. PRIOR TO BEGINNING WORK, THE CONTRACTOR SHALL VISIT THE SITE OF THE JOB AND SHALL FAMILIARIZE HIMSELF WITH THE CONDITIONS AFFECTING THE PROPOSED ELECTRICAL INSTALLATION AND SHALL MAKE PROVISIONS AS TO THE COST THEREOF. FAILURE TO COMPLY WITH THE INTENT OF THIS SECTION WILL IN NO WAY RELIEVE THE CONTRACTOR OF PERFORMING THE WORK NECESSARY FOR A COMPLETE AND WORKING SYSTEM OR SYSTEMS. CUTTING, PATCHING AND EXCAVATION: 1. COORDINATION OF SLEEVES, CHASES, ETC , BETWEEN SUBCONTRACTORS WILL BE REQUIRED PRIOR TO THE CONSTRUCTION OF ANY PORTION OF THE WORK CUTTING AND PATCHING OF WALLS, PARTITIONS, FLOORS, AND CHASES IN CONCRETE, WOOD, STEEL OR MASONRY SHALL BE DONE AS PROVIDED ON THE DRAWINGS. 2. NECESSARY EXCAVATIONS AND BACKFILLING INCIDENTAL TO THE ELECTRICAL WORK SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWING. 3. SEAL PENETRATIONS THROUGH RATED WALLS, FLOORS, ETC., WITH APPROVED METHOD AS LISTED BY UL. RACEWAYS I CONDUITS GENERAL: 1. CONDUCTORS SHALL BE INSTALLED IN LISTED RACEWAYS. CONDUIT SHALL BE RIGID STEEL, EMT, SCH40 PVC, OR SCH80PVC AS INDICATED ON THE DRAWINGS. THE RACEWAY SYSTEM SHALL BE COMPLETE COMPLETE BEFORE INSTALLING CONDUCTORS. 2. EXTERIOR RACEWAYS AND GROUNDING SLEEVES SHALL BE SEALED AT POINTS OF ENTRANCE AND EXIT. THE RACEWAY SYSTEM SHALL BE BONDED PER NEC. EXTERIOR CONDUIT: 1. EXPOSED CONDUIT SHALL BE NEATLY INSTALLED AND RUN PARALLEL OR PERPENDICULAR TO STRUCTURAL ELEMENTS. SUPPORTS AND MOUNTING HARDWARE SHALL BE HOT DIPPED GALVANIZED STEEL. 2. THE CONDUIT SHALL BE RIGID STEEL AT GRADE TRANSITIONS OR WHERE EXPOSED TO DAMAGE. 3 UNDERGROUND CONDUITS SHALL BE RIGID STEEL, SCH40 PVC, OR SCH80 PVC AS INDICATED ON THE DRAWINGS. 4. BURIAL DEPTH OF CONDUITS SHALL BE AS REQUIRED BY CODE FOR EACH SPECIFIC CONDUIT TYPE AND APPLICATION, BUT SHALL NOT BE LESS THAN THE FROST DEPTH AT THE SITE. 5. CONDUIT ROUTES ARE SCHEMATIC. CONTRACTOR SHALL FIELD VERIFY ROUTES BEFORE BID. COORDINATE ROUTE WITH WIRELESS CARRIER AND/OR BUILDING OWNER. INTERIOR CONDUIT: 1. CONCEALED CONDUIT IN WALLS OR INTERIOR SPACES ABOVE GRADE MAY BE EMT OR PVC. 2. CONDUIT RUNS SHALL USE APPROVED COUPLINGS AND CONNECTORS. PROVIDE INSULATED BUSHING FOR ALL CONDUIT TERMINATIONS. CONDUIT RUNS IN A WET LOCATION SHALL HAVE WATERPROOF FITTINGS. 3. PROVIDE SUPPORTS FOR CONDUITS IN ACCORDANCE WITH NEC REQUIREMENTS. CONDUITS SHALL BE SIZED AS REQUIRED BY NEC EQUIPMENT: 1. DISCONNECT SWITCHES SHALL BE SERVICE ENTRANCE RATED, HEAVY DUTY TYPE 2. CONTRACTOR SHALL VERIFY MAXIMUM AVAILABLE FAULT CURRENT AND COORDINATE INSTALLATION WITH THE LOCAL UTILITY BEFORE STARTING WORK CONTRACTOR WILL VERIFY THAT EXISTING CIRCUIT BREAKERS ARE RATED FOR MORE THAN AVAILABLE FAULT CURRENT AND REPLACE AS NECESSARY. 3. NEW CIRCUIT BREAKERS SHALL BE RATED TO WITHSTAND THE MAXIMUM AVAILABLE FAULT CURRENT AS DETERMINED BY THE LOCAL UTILITY. CONDUCTORS: 1. FURNISH AND INSTALL CONDUCTORS SPECIFIED IN THE DRAWINGS. CONDUCTORS SHALL BE COPPER AND SHALL HAVE TYPE THWN (MIN) (75' C) INSULATION, RATED FOR 600 VOLTS. 2. THE USE OF ALUMINUM CONDUCTORS SHALL BE LIMITED TO THE SERVICE FEEDERS INSTALLED BY THE UTILITY. 3. CONDUCTORS SHALL BE PROVIDED AND INSTALLED AS FOLLOWS: A. MINIMUM WIRE SIZE SHALL BE #12 AWG B. CONDUCTORS SIZE 18 AND LARGER SHALL BE STRANDED CONDUCTORS SIZED #10 AND #12 MAY BE SOLID OR S RANDED. C. CONNECTION FOR y10 AWG q12 AWG SHALL BE BY TWISTING TIGHT AND INSTALLING INSULATED PRESSURE OR WIRE NUT CONNECTIONS. D. CONNECTION FOR #8 AWG AND LARGER SHALL BE BY USE OF STEEL CRIMP -ON SLEEVES WITH NYLON INSULATOR. 3 CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NEC STANDARDS. UL COMPLIANCE: 1 ELECTRICAL MATERIALS, DEVICES, CONDUCTORS. APPLIANCES. AND EQUIPMENT SHALL BE LABELED/LISTED BY UL OR ACCEPTED BY JURISDICTION (I.E., LOCAL COUNTY OR STATE) APPROVED THIRD PARTY TESTING AGENCY. GROUNDING: 1. ELECTRICAL NEUTRALS, RACEWAYS AND NON -CURRENT CARRYING PARTS OF ELECTRICAL EQUIPMENT AND ASSOCIATED ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH NEC ARTICLE 250. THIS SHALL INCLUDE NEUTRAL CONDUCTORS, CONDUITS, SUPPORTS. CABINETS, BOXES, GROUND BUSSES, ETC. THE NEUTRAL CONDUCTOR FOR EACH SYSTEM SHALL BE GROUNDED AT A SINGLE POINT. 2. PROVIDE GROUND CONDUCTOR IN RACEWAYS PER NEC. 3. PROVIDE BONDING AND GROUND TO MEET NFPA 780 - "LIGHTNING PROTECTION" AS A MINIMUM 4. PROVIDE GROUNDING SYSTEM AS INDICATED ON THE DRAWINGS, AS REQUIRED BY THE NATIONAL ELECTRIC CODE, RADIO EQUIPMENT MANUFACTURERS, AND MOTOROLA R56 (AS APPLICABLE). II ABBREVIATIONS AND LEGEND II A AMPERE AFG ABOVE FINISHED GRADE ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BCW BARE COPPER WIRE BFG BELOW FINISHED GRADE SKR BREAKER C CONDUIT CKT CIRCUIT DISC DISCONNECT EGR EXTERNAL GROUND RING EMT ELECTRIC METALLIC TUBING FSC FLEXIBLE STEEL CONDUIT GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM GRID GROUND IGB ISOLATED GROUND BAR IGR INTERIOR GROUND RING (HALO) KW KILOWATTS NEC NATIONAL ELECTRIC CODE PCS PERSONAL COMMUNICATION SYSTEM PH PHASE PNL PANEL PNLBD - PANELBOARD PVC - RIGID NON-METALLIC CONDUIT RGS - RIGID GALVANIZED STEEL CONDUIT SW - SWITCH TGB - TOWER GROUND BAR UL - UNDERWRITERS LABORATORIES V - VOLTAGE W - WATTS XFMR - TRANSFORMER XMTR - TRANSMITTER E - - - - UNDERGROUND ELECTRICAL CONDUIT T - - - - UNDERGROUND TELEPHONE CONDUIT 8 KILOWATT-HOUR METER UNDERGROUND BONDING AND GROUNDING CONDUCTOR. 0 GROUND ROD CADWELD GROUND ROD WITH INSPECTION WELL PLANS PREPARED FOR: verizon,' 4700 EXCHANGE COURT, SUITE 100 BOCA RATON, FL 33431 PROJECT INFORMATION: VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD. FL 32773 SEMINOLE COUNTY) PLANS PREPARED BY: LN N TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup.net FL COA # 30978 SE AL: No 83802 =_ STATE OF ORIDP 0INA II I 11\ 511ay 30, 2018 1 05-30-15 CON5TRUCTION 0 04-10- 18 PRELIMINARY REV DATE ISSUED FOR: DRAWN BY: 565 1 CHECKED BY: C51`1 SHEET TITLE: ELECTRICAL NOTES SHEET NUMBER: REVISION: 1E-1 TEP#: 84603.94 199 GENERAL NOTES: 1. CONTRACTOR SHALL COORDINATE INCOMING SERVICES WITH LOCAL UTILITIES PRIOR TO TRENCHING. 2. ALL CONDUCTORS SHALL BE COPPER, 75 DEGREES C RATED. AND CONDUCTOR INSULATION SHALL BE THWN OR THHN 3. ALL TERMINATIONS SHALL BE LISTED AND IDENTIFIED FOR USE WITH 75'C RATED CONDUCTORS OPERATING AT 75•C. 4. GROUND FAULT PROTECTION REQUIRED FOR UTILITY RECEPTACLES. UTILITY POWER SUPPLY 5. SERVICE NEUTRAL SHALL BE GROUNDED AT ONE LOCATION 120/24OV, 10, 3W ONLY. 6. WHITE/NEUTRAL. GREEN/GROUND SHALL BE MAINTAINED THROUGHOUT THE SITE ELECTRICAL SYSTEM (TAPE WILL NOT BE ACCEPTABLE). 7. EOUIPMENT LOCATED OUTSIDE OR EXPOSED TO MOISTURE SHALL BE NEMA 3R RATED. 8. CONTRACTOR SHALL USE SCHEDULE 80 PVC CONDUIT THROUGHOUT, UNLESS OTHERWISE NOTED 9. ALL NEWLY INSTALLED EOUIPMENT SHALL BE RATED AT 10K AIC MINIMUM. HIGHER RATINGS SHALL BE REQUIRED WHERE AVAILABLE FAULT CURRENT EXCEEDS THIS VALUE. EXACT FAULT CURRENT AVAILABLE SHALL BE COORDINATED WITH LOCAL UTILITY BASED ON EXACT CONDITIONS XFMR SIZE, PERCENT IMPEDANCE, LENGTH OF CONDUCTORS, ETC) 10. ONE —LINE DIAGRAM BASED OFF PHOTOS SUPPLIED BY VERIZON. CONTRACTOR TO NOTIFY TEP OF ANY DISCREPANCIES EQUIPMENT SERVICE ONE -LINE DIAGRAM SCALE: N T.S. EXISTING 200A MAIN PANEL. SEE SHEET E-3 FOR SCHEDULE.— 1) 1" CONDUIT W/ 2)—#10 AND (1)—#10 GNDs FOR DARK FIBER f f 1) 9X_ CONDUIT W/ (2)—#10 AND 1)—#10 GNDs FOR DARK FIBER EXISTING 200A, 120/240V PANEL BOARD. SEE SCHEDULE ON SHEETS E-3. PROPOSED RELOCATED 30A BREAKER FOR DARK FIBER PROPOSED 125A BREAKER TO REPLACE EXISTING r 30 125 EXISTING 200A METER SEE NOTES 1 do 4. M EXISTING 200A DISCONNECT EXISTING GROUND EXISTING POWER CONDUIT TO MAIN PANEL 200 1) 1)" CONDUIT W/ (3)—#1 AND 1)—#6 GNDs FOR CUBE EXISTING PROPOSED 125A SUBPANEL TODARK FIBER REPLACE EXISTING t00A SUBPANEL FOR CABINET CUBE. SEE SHEET E-3 FOR SCHEDULE. 1) 1}2" CONDUIT W/ (8)—#8 AND (4)—#8 f GNDs FOR POWER TO RECTIFIERS 1 1 1 1 1--------------------- ELECTRICAL ROUTING PLAN SCALE: N.T.S. PROPOSED CUBE SS4B228LX1 1) 1}Z" CONDUIT W/ (8)—#8 AND (4)—#8 GNDs FOR POWER TO RECTIFIERS 1) )" CONDUIT W/ (2)—#12 AND 1)—#12 GNDs FOR POWER TO GFCI PROPOSED 125A SUBPANEL. SEE SHEET E-3 FOR SCHEDULE. 1) 1)" CONDUIT W/ 3)—#1 AND (1)—#6 GNDs FOR SUBPANEL PLANS PREPARED FOR: verizon-1 4700 EXCHANGE COURT, SUITE 100 BOCA RATON, FL 33431 PROJECT INFORMATION: VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD, FL 32773 SEMINOLE COUNTY) PLANS PREPARED BY: TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup.net FL COA # 30978 SEAL: 0111111 // C r No 83902 P _ simlie o STATE OF j F F OR10P G\ ONA1I1; lfay 30, 2018 1 05-30- 15 C01,15TRUCTION O 04-10-15 PRELIMINARY REV DATE ISSUED FOR: DRAWN BY: 5135 1 CHECKED BY: C514 SHEET TITLE: EQUIPMENT SERVICE ONE - LINE DIAGRAM SHEET NUMBER: REVISION: E- 2 1 TEP #: 84603. 114 199 NOTE: LOADING TAKEN FROM POWER BILLS & PHOTOS SUPPLIED BY VERIZON WIRELESS. CONTRACTOR TO NOTIFY TEP OF ANY DISCREPANCIES. 200A9 120/240V M.C.B. POWER PANEL SCHEDULE LOAD SERVED VOLT AMPERES WATTS) TRIP CKT PHASE CKT TRIP VOLT AMPERES WATTS) LOAD SERVED L1 L2 L1 L2 4720 1 A 2 4536 BTS 1 100 80 Ev0 4720 3 B 4 3024 100 5 A 6 950 GEN PIN RELAY 20 20 BATTERY CABINET 100 7 B 8 950 100 9 A 10 20 180 GEN RECEPTACLE ZONEMASTER 150 SURGE 60 100 11 B 12 BLANK VOLT AMPS 4920 4920 5666 1 3974 1 VOLT AMPS L1 VOLT AMPERES 10586 8894 L2 VOLT AMPERES L1 AMPS 882 74.1 L2 AMPS 88.2 MAX AMPS 110.3 MAX AMPS x125% NUIL - UUL CAIJINLI FLU by UHLAKLK IU tit KLPLAULU EXISTING MAIN PANELBOARD SCHEDULE SCALE: N.T.S. 200A, 120/240V M.C.B. POWER PANEL SCHEDULE VOLT AMPERES VOLT AMPERES LOAD SERVED WATTS) TRIP CKT PHASE CKT TRIP WATTS) LOAD SERVED L1 I L2 I L1 L2 4720 1 A 2 10000 BTS t77 100 125 125A CUBE SUBPANEL a720 3 B 4 10180 100 A 6 950 GEN PIN RELAY 20 20 BATTERY CABINET 100 F7+ B 8 950 100 GEN RECEPTACLE ZONEMASTER 150 SURGE 60 100 HA3 1512 DARK FIBER CABINET VOLT AMPS 4920 4920 11130 14010 VOLT AMPS L1 VOLT AMPERES 16050 17562 L2 VOLT AMPERES L1 AMPS 133.8 146.4 L2 AMPS 146.4 MAX AMPS 182.9 MAX AMPS x125% PROPOSED MAIN PANELBOARD SCHEDULE SCALE: N.T.S. EXISTING 100A, 120/240V VZW SUBPANEL LOAD SERVED VOLT AMPERES WATTS) TRIP CKT PHASE CKT TRIP VOLT AMPERES WATTS) LOAD SERVED L1 L2 L1 L2 LTE CABINET 3024 60 1 n tA A 2 30 1512 DARK FIBER CAB 3024 3 B 4 SPARE SPARE 5 A 6 SPARE SPARE 7 B 8 SPARE SPARE 9 A 10 SPARE SPARE 11 B 12 SPARE SPARE 13 14 SPARE SPARE 15 16 SPARE SPARE 17 18 SPARE SPARE 19 B 20 SPARE SPARE 2tJA 22 SPARE SPARE 23 24 SPARE VOLT AMPS 3024 3024 1 1512 VOLT AMPS L1 VOLT AMPERES 4536 3024 L2 VOLT AMPERES Lt AMPS 37.8 25.2 L2 AMPS 37.8 MAX AMPS 47.3 MAX AMPS 025% NUIL - L1CQ>IINU IUUA VZW Z)ULWANLL IU UL KLMUVtU; )UA UAKK FIbtK I.AbINLI CKLAKLK IV bt RELOCATED TO MAIN PANEL EXISTING VERIZON SUBPANELBOARD SCHEDULE SCALE: N.T.S. IF -PROPOSED 125A, 120/240V CUBE SUBPANEL LOAD SERVED VOLT AMPERES WATTS) TRIP CKT PHASE CKT TRIP VOLT AMPERES WATTS) LOAD SERVED L1 L2 L1 L2 RECTIFIER #1 2500 30 1 A 2 30 2500 RECTIFIER #2 RECTIFIER 73 2500 30 3 B 4 30 2500 RECTIFIER #4 RECTIFIER #5 2500 30 5 A 6 30 2500 RECTIFIER #6 RECTIFIER #7 2500 30 7 B 8 30 2500 RECTIFIER #8 SPARE 9 A 10 SPARE SPARE 11 B 12 20 180 GFCI VOLT AMPS 5180 5000 5000 5000 1 VOLT AMPS L1 VOLT AMPERES L1 AMPS 10000 848 84.8 106.0 10180 83.3 L2 VOLT AMPERES L2 AMPS MAX AMPS MAX AMPS 025% NUIL - NKUF'UJLU 11JA LIL tlKLAKLK IU FLLU F'KUF'UJtU 125A L;UbL JUb-F'ANLL PROPOSED CUBE SUBPANEL SCHEDULE SCALE: N.T.S. PLANS PREPARED FOR: verizon,v' 4700 EXCHANGE COURT, SUITE 100 BOCA RATON, FL 33431 PROJECT INFORMATION: VZW SITE #: 132046 VZW SITE NAME: SANFORD PLAZA 2921 S ORLANDO DRIVE SANFORD, FL 32773 SEMINOLE COUNTY) PLANS PREPARED BY: A 11 k4'111 -4m"00— TOWER ENGINEERING PROFESSIONALS 326 TRYON ROAD RALEIGH, NC 27603-3530 OFFICE: (919) 661-6351 www.tepgroup.net FL COA # 30978 SEAL: No 902 5i 1 IrlSTATE OF i 0' F OR10P s9/ NAL E? \\ IIl I\\\ 11ay30,2018 1 05-30-I8 C0145TRUCTION O 04-1 0- 18 PRELIMINARY REV DATE ISSUED FOR: DRAWN BY: 555 1 CHECKED BY: C5N SHEET TITLE: PANELBOARD SCHEDULES SHEET NUMBER: REVISION: 1E-3 TEP#: 84603.94 1 99 NOTES: PLANS PREPARED FOR: 1. DO NOT INSTALL COAX GROUND KIT AT A BEND. Verizon,/ 2.CONTRACTOR TO WEATHERPROOF COAX GROUND. 4700 EXCHANGE COURT, SUITE 100 BOCA RATON. FL 33431 STAINLESS STAINLESS STEEL BOLT STEEL NUT PROJECT INFORMATION: STAINLESS STEEL VZW SITE M 132046BELLEVILLEWASHER ANTENNA COAX VZW SITE NAME: CABLE. SANFORD PLAZAO 2921 S ORLANDO DRIVE O O SANFORD, FL 32773 O STAINLESS STEEL COPPER SEMINOLE COUNTY) FLAT WASHER BUS BAR PLANS PREPARED BY: 0 N6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR). UNIVERSAL GROUND KIT BY HARGER OR APPROVED NOTES: 1. ALL HARDWARE SHALL BE 18-8 STAINLESS STEEL. INCLUDING THE BELLEVILLE WASHERS. COAT ALL SURFACES WITH KOPR-SHIELD BEFORE MATING. TOWER ENGINEERING PROFESSIONALS 2. FOR GROUND BOND TO STEEL ONLY; INSERT A DRAGON TOOTH WASHER BETWEEN 26T RYON ROAD THE LUG AND STEEL. COAT ALL SURFACES WITH KOPR—SHIELD. RAL3NC 2ROAD26T 530OFFICE: ( 919) 661-6351 GROUNDING DETAILS TYPICAL LUG DETAILS www.tepgroup.net SCALE: N.T.S. SCALE: N T S. FL COA # 30978 SEAL: IIII III III I 11x1" H.H.C.S. BOLT, WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. j C NEWTON INSTRUMENT CO. CAT y 3012-1). CAT. y A-6056). N 83902 TYPE GR INSULATORS, NEWTON INSTRUMENT CO. splls * * CAT y 3061-4). a STATE OF jr TYPE GY TYPE GR I o/// i - p (( 0OR10P- ONAL E Q 111 \ 0 0 0 , , LOCKWASHER, ® ° 0 ° 0 Yl. In 111 51ray 30, 2018 TYPE VB NEWTON INSTRUMENT CO. 0 0 CAT.# 3015-8). TOWER GROUNDING TAB) I 05-30- 18 COIJSTRUCTION I 0 0 04-1 O- 18 PRELIMINARY I REV DATE ISSUED FOR: DRAWN BY: 5135 CHECKED BY: C51.1 COPPERGROUNDBARVx4%20" MIN. NEWTON INSTRUMENT CO CAT.// 8-6142. HOLE CENTERS TO MATCH NEMA DOUBLE SHEET TITLE: TYPE NC TYPE GT LUG CONFIGURATION. NOTE: 111 GROUNDING CADWELD " TYPES" SHOWN ARE EXAMPLES. CONSULT WITH HEAT SHRINK ON NOTE: DETAILS PROJECT MANAGER FOR SPECIFIC TYPES OF CADWELDS TO BE USED FOR THIS PROJECT GATES ONLY KD GROUND BAR SHALL BE SIZED TO ACCOMMODATE ALL GROUNDING SHEET NUMBER: REVISION: TYPE vBC CONNECTIONS REOUIRED AS WELL AS PROVIDE 50% SPARE CAPACITY TYPICAL CADWELD DETAILS STANDARD GROUND BAR DETAILS 1 TEP#: 84GO3 94199 SCALE: N.T.S. SCALE: N.T.S. 7