Loading...
HomeMy WebLinkAbout3440 St Johns Pkwy 1074 18-1986; NEW SFHCOUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 18100004 DATE: May 03, 2018 I . BUILDING APPLICATION #: 18-10000425 t BUILDING PERMIT NUMBER: 18-10000425 UNIT ADDRESS: ST JOHNS PKWY 3440 UNITS 3&4 26-19-30-5AE-2900-0000 ,- TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: J&K SANFORD LLC ADDRESS: 215 CLERMONT RD LAKE MARY FL 32746 LAND USE: BLDG B WAREHOUSE/OFFICE TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 7500 SF JOHNS PKWY UNITS 3&4 W/OFFICE/ FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUE TYPE DIST SCHED RATE UNITS TYPE ROADS -ARTERIALS CO -WIDE Office ROADS -COLLECTORS N/A Office FIRE RESCUE N/A LIBRARY N/A SCHOOLS N/A PARKS N/A LAW ENFORCE N/A DRAINAGE N/A CREDIT FEES: SCI ROAD ARTERIALS C warehousing* ORD 1,545.00 00 118 1000g5ft 182.31 118 1000gsft .00 00 00 00 00 00 00 358.00 118 1000gsft 42.24- AMOUNT DUE 140.07 PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PE IT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE DATE ABOVE, BUT NO LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE BUSINESS OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE, THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT ISSUED WITHIN 60 CALENDAR DAYS FROM THE DATE ABOVE i L A444t CITY OF FORD FIRE DEPARThIENT' Building & Fire Prevention Division PERMIT APPLICATION 1 App i ti 0: 9-- C rl ctiowtimentedConstructio Value: $ Job Address: ,- IL 4' slJUt/ L J 7LL) -- (I - 210-, C41ParcelID: Type of Work: NewE] AdditionF AlterationFIRepair Description of Work: Plan Review Contact Person: Phone: Fax: of Historic District: VesE]NoF] Residentialo CommercialFt Demo E]Change of Use El Moveo Property Owner Information r" I Name _ Lai 'LPhone: LAO-7 H2=1 Z-_S2,>2_ Street: 6- Resident of property? 0 City, State Zip: Name _ ') tT Street: City, State Zip: Name: Street: City, St, Zip: Bonding Company: Address: r Information Phone: Fax: State License No.: Architect/ Engineer Information C 5 c- J&/ Phone: nD ALM&H WHRM', Fax: day) E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code it) effect as of that date: 6h Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. STEPHANIE RALLO Commission # FF 175017 Expires November 9, 2018 W4W Th u T 114010me W-M-7010 Owne[Agenrtersonal ly Known to Me or Produced ID Type of ID Signature of Contractor/Agent Date Print Contractov, Agent's Name Signature of Notary -State of Florida Date Contractor/ Agent is Personally Known to Me or Produced ID _ Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building F ElectricaIE] Mechanical E] Plumbing[] GasEl Roof El Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: YesFJ No[] APPROVALS: ZONING: ENGINEERING: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures of Heads Fire Alarm Permit: Yes [] No [] UTILITIES: WASTE WATER: FIRE: BUILDING: X. Revised: January 1, 2018 Permit Application A CITY OF P ORD DEPARTMENTFIRE Building & Fire Prevention Divisionar "_ PERMIT APPLICATION Application No: t _ Documented Construction Value: $ 1 Job Address: I & S_PJZ±3 Historic District: Yes No11 Parcel ID: z' i ( — Type of Work: New[] Description of Work: Plan Review Contact Person: AIteration Repair Residential Commercial Demo Change of Use Move R Title: Phone: 3Fax: i SB51CO2 Email: 01 Property Owner Information an Name i^ Phone: HO-7 tt ' 5 _' 2 Street: '' Resident of property? City, State Zip: Name Street: City, S Name: Street: City, St, Zip: Bonding Company: Address: X hone: sax: State License No.: P 51*1 Arch itectlEngineer Information Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shalt be inscribed with the date of application and the code in effect as of that date: 61h Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NQJJIE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER' S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 645/ 4 cl_ S igna c o Owner/Agent Date ign, c Owner/Agent P o c Print01cr-gent's Narvc i Lfha , Mn ,paj, yLateSiatureot'Kota-kate of Florida Date ALLO RSTEPHANIERALLO # Commission # FF 175017 m rg, 18 Commission 20 ExpiresNovember9, 2018 "_.w sas", GoModTh(u T owne[ agerif is 4,,f Persona y own to Me or Produced ID Type of ID Signature of Contractor/Agent Date Print Contractor/Agent's Name Signature of Notary -State of Florida Date Contractor/ Agent is Personally Known to Me or Produced ID _ Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building [] ElectricalE] Mechanical F1 Plumbingn Gas[] RoofE] Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: YesE] NoF] # of Heads Fire Alarm Permit: YesE] NOE] APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: WASTEWATER: FIRE: BUILDING: Revised: January 1, 2018 Permit Application INSPECTION SEQUENCE BP# 18-1986 ADDRESS: 3440 St Johns Parkway BUILDING PERMIT Min Max Inspection Description Footer / Setback Sternwall 10 Slab / Mono Slab Lintel / Tie Beam / Fill Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In 20 Frame 30 Insulation Rough Firewall Screw Pattern 40 Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com'l) Building Ceiling Grid Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence Final Commercial — 1000 Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) ALE%2 Max Inspection DescriptionMin Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough 10 Electric Rough Pre -Power Final Temporary Pole 1000 Electric Final Min Max g Inspection Description Rough Plumb 10 Plumbing Underground 20 Plumbing 2 d Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough 1000 Plumbing Final Min Max Inspection Description 10 Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap 1000 Mechanical Final REVISED: June 2014 N THIS IJ E - Y: Name: NAdd NOTICE OF COMMENCEMENT State of Florida County of Seminole Permit Number: Parcel ID Number: ZLL — 19-3t --4.5 ( ZC71"G ) The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) 1; 13) GENERAL DESCRIPTION OF IMPROVEMENT: off *: i u k T Address: Fee Simple Title Holder (if other than owner) Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provide y ectio 713.13(1)(b),.,F4o ' tatu#es. Name: tt Address: t In addition to himself, Owner Designates of To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that 1 have read the foregoing and that the facts stated in it are true to the best of y nowi 'andelief. Owner' s Signature Owner's Printed Name Florida Statute 713.13(t)(9): ' The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead," State of I County of V I C-- The foregoin instrument was acknowledged before me this day of AI 20 by j Who is personally known to me Name o person making statement OR who has produced identification type of identificatio prod ed: ^ a .;. A------ .: L CITY OF FORU FIRE DEPARTMENT 4 Building & Fire Prevention Division PERMIT APPLICATION Application Na: 17— IqX Documented Construction Value: $ I 1 0 Job Address: 6LLf) VJAJ iZq- 0 Historic District: Yes E]No Parcel ID: (S A- F_ - ResidentialFICommercial Type of Work: NewE]Addition [I AlterationE]RepairE]DemoE]Change of UseElMove Description of Work: Plan Review Contact Person: Title: Phone: a2:192 AQ 1113 Fax: SESIOD2 Email:, Ica Property Owner Information Name Phone: Street: Resident of property? d City, State Zip: Name Street: City, S1 Name: Street: City, St, Zip: cation Phone: Fax: State License No.: E2 31' Architect/Engineer Information Phone: Fax: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6" Edition (2017) Florida Building Code Revised: January 1, 20 18 Permit Application h[Q110E: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. loft STEPHANIE RALLO Commission # FF 175017 Expires November 9, 2018 511 Sbonded= an Ins — Soo W-7010 OwneAgeffrgersonally awn to Me or Produced ID Type of ID Signature of Contractor/Agent —Date Print Contractor/ Agent's Name isSignature of Notary -State of Florida Date Contractor/Agent is _ Personally Known to Me or Produced ID _ Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: BuildingE] Electrical[] MechanicalE] Plumbingn GasE] RoofE] Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: YesE] NoFJ # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: YesFJ NoE] UTILITIES: WASTE WATER: FIRE: Revised: January 1, 2018 Permit Application UJITY OF, SkNFORD DEPARTMENTFIRE i Building & Fire Prevention Division PERMIT APPLICATION Application No: Documented Construction Value: $ 0 V 15o Job Address: o ,, l Historic District: Yes No1:1 Parcel ID: - -' - Residential[] Commerciale Type of Work: NewE]Addition Alteration Repair E]Demo Change of UseF]Move Description of Work: Plan Review Contact Person: n 4 Phone: EU:Iqa Q I t 1,3 Fax: 3, 5a5 ,Email: Property Owner Information ccam,, Y) Name Phone: - % ^ 2-52-2 Street: Resident of property? r City, State Zip: Name Street: City, S 1 Name: Street: City, St, Zip: Bonding Company: Address: M Phone: Fax: Hn- i 1 ?. State License No.: Arch itect/EngIneer Information Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 611 Edition (2017) Florida building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signa e a Owner/Agent Date Print QG er gent's Na e hn sipature of t1otary-fate of Flor'id—a Date STEPHANIE RALLO 57801 e &crated Thou T an 1. 201 is y Commission # FF 175017 tember 9, 2018ExpiresNoi ataOwneEeFersonallown to Me or Produced ID Type ofID Signature of Contractor/Agent Print Contractor/Agent's Name Date Signature of Notary -State of Florida Date Contractor/Agent is Personally Known to Me or Produced ID _ Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building D ElectricaIF] Mechanical [] Plumbing[] GasF] Roof[] Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: YesF] No [:] # of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes[-] No] WASTE WATER: BUILDING: COMMENTS: P 2-1d`ll ze) Revised: January 1, 2018 Permit Application et C ttw? Building & Fire Prevention Division PERMIT APPLICATION Application No: Documented Construction Value: $ ?1 i Sd Job Address: l "t- Historic District: Yes Noll Parcel ID: _ zResidentialElCommercial Type of Work: New Addition Alteration Repair Demo Change of Me Move Description of Work: Plan Review Contact Person: Title: Phone: =Q . j, } Fax: U SaEmail: Property Owner Information Name Phone: 2 G12 Street: Resident of property? : City, State Zip: Contractor Information Name t i Phone: Street:DVIA1Fax: l City, State Zip: Stake License No.: Name: Street: City, St, Zip: Bonding Company: Address: Architect/ Engineer Information Phone: Fax: E- mail: _ Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105. 3 Shall be inscribed with the date of application and the code in effect as of that date: 61' Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued, OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Date Signature of Contractor/Agent Date Print Contractor/Agent's Name Date Signature of Notary -State of Florida Date STEPHANIE RALLO Commission # FF 175017 Expires November 9, 20186=_4019 eOwn , t,` — . =_ [ i _=Fersonally own to Me or Contractor/Agent is Personally Known to Me or Produced ID Type of ID Produced ID _ Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: BuildingEl Electrical F1 MechanicaIE] PlumbingE] Gas[] RoofE] Construction Type: Total Sq Ft of Bldg: Occupancy Use: Flood Zone: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes n No [:] APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: Plumbing - # of Fixtures Fire Alarm Permit: YesE] NoE] WASTE WATER: FIRE: - BUILDING: Revised: January 1, 2018 Permit Application DATE: 2 1, /19 BUSINESS/PROJECT NAME: ADDRESS: CONTACT NAME: 0 CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION FIRE PLAN REVIEW SERVICE FEES PHONE: 407.688.5052 FAX: 407.688.5051 PERMIT NUMBER: / f- - / J- PHONE: PLAN REVIEW INFORMATION IYIC04NSTRUCTION [ ]C/O FIRE ALARM I I FIRE SPRINKLER [ ] HOOD [ ]PAINT BOOTH [ ]TANK DOES 20% REDUCTION IN FIRE IMPACT FEES APPLY: YES NO tf TOTAL FEES: r-1 . orn 201.7, :Effe:c Option Check List Applications for compliance with the Florida Building Code, Energy Conservation shall include: This Checklist Er The full compliance report generated by the software that contains the project summary, compliance summary, certifications and detailed component compliance reports. The compliance report must include the full input report generated by the software as contigous part of the compliance report. Boxes appropriately checked in the Mandatory Section of the complaince report. WARNING: INPUT REPORT NOT GENERATED. To include input report in final submission, go to the Project Form, Settings Tab and check the box - "Append Input Report to Compliance Output Report" Then rerun your calculation EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Option 4/9/2018 Page 1 of 15 PROJECT SUMMARY Short Desc: JKLLC Owner: Cox Construction and Development Addressl: 3400 St. John's Parkway Address2: Units 2 & 3 Description: J&K LLC Building B City: State: Zip: Type: Office Class: Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Conditioned Area: 868 SF Conditioned & UnConditioned Area: No of Stories: I Area entered from Plans Permit No: 0 Max Tonnage If different, write in: Sanford FL 32771 Renovation to existing 868 SF 868 SF 2.9 EnergyGauge Summit® Fla/Com-2017. TAM 2017-1,0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Option 4/9/2018 Page 2 of 15 Compliance Summary Component Design Criteria Result Gross Energy Cost (in $) 598.0 727.0 PASSED LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES No Entry PASSES No Entry No Entry No Entry Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit® Fla/Com-2017, TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Option 4/9/2018 Page 3 of 15 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Building Official: Date: 4/9/18 Date: I I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: If Required by Florida law, I he Efficiency Code Archi Electrical Designer: Lighting Designer: Mechanical Designer: it Date: design is in compliance with the Florida Energy Reg No: - Reg No: Reg No: Reg No: Plumbing Designer: (( I Reg No: ( ( Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Option 4/9/2018 Page 4 of 15 Project: JKLLC Title: J&K LLC Building B Interior Office Build -Out Type: Office WEA File: FL_ORLANDO_SANFORD_AIRPORTAW) Building End Uses 1) Proposed 2) Baseline Total 38.20 46.60 598 727 ELECTRICITY(lVlBtulkWhl$) 38.20 46.60 11183 13665 598 727 AREA LIGHTS 2.50 10.10 735 2950 39 157 MISC EQUIPMT 13.00 13.00 3814 3814 204 203 PUMPS & MISC 0.10 0.10 15 17 1 1 SPACE COOL 11.20 10.20 3288 2995 176 159 SPACE HEAT 0.80 0.90 225 274 12 15 VENT FANS 10.60 12.30 3106 3615 166 192 Credits Applied: None PASSES Passing Criteria = 727 Design (including any credits) = 598 Passing requires Proposed Building cost to be at most 100%Q of Baseline cost. This Proposed Building is at 82.3% EnergyGauge Summit) Fla/Gam-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Option 419f2018 Page 5 of 15 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP Project: JKLLC Title: J&K LLC Building B Interior Office Build -Out Type: Office Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- Project: JKLLC Title: J&K LLC Building B Interior Office Build -Out Type: office System Report Compliance PrOSyl System I Constant Volume Air Cooled No. of Units Component Category Capacity Design Eff Design IPLV Comp - Cooling System Air Conditioners Air Cooled 35000 14.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 27297 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1200 0.80 0.82 PASSES System -Supply Constant Volume PASSES EnergyGauOoSummh@FlaKCom-2017TAM 2017'1.OCompliant Software. Effective Date: Dec 31.2O17 Florida Building Code, Sixth Edition (2O1T)-Energy Conservation A8HRAE9&1-2O13'Energy Cost Budget Option Plant Compliance Description Installed Size Design Min Design No Eff Eff IPLV Min Category Comp IPLV fiance I I None Water Heater Compliance Description Type Category Design Min Eff Eff Design Max Comp Loss Loss fiance C None Piping System Compliance Category Pipe Dia Is Operating Ins Cond inches] Runout? Temp [Btu-in/hr F] SF.Fj Ins Req Ins Compliance Thick [in] Thick [in] I None EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Option 4/9/2018 Page 7 of 15 Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department of Energy and Pacific Northwest National Laboratory, Adopted with permission Topic Section Component Description Yes N/A Exempt Insulation 5.0.1.2 Envelope installed per manufacturerEICTMS'----- r Insulation 5.8.12 Envelope 8 bedge inuv Voninam|d nmun m uc U 1 inmm ionu. naummvn 5.5.3.5 en"o|upe Slab edge insulation ueptxxongm. now|mu|on 84.4.1.5 Envelope Bottom surface offloor structures incorporating radiant heating insulated mp=R-3.5. Fenestration 5.5.3a envelope u-faum,oopaque doors associated with the building thermal envelope meets requirements. SYSTEM—SPECIFIC 5.5.1.6.51.1. Mechanical Air economizers provided where required(and not 6.5. 1.3,0,5./.4 exempted), meet the requirements for design capacity, control signal, ventilation controls, high -limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. SYSTEM —SPECIFIC 6a.1.6.1.2. Mechanical economizers provided where required, 1.3 meet the requirements for design capacity, maximum pressure drop and integrated economizer control. SYSTEM —SPECIFIC 6.5.1 5 Mechanical Economizer operation will not increase heating energy use during normal operation. SYSTEM 6. 5.2.2.1 Mechanical Thmu1 pooydmniusystems using acommon SPECIFIC SYSTEM —SPECIFIC6. 5.2.23 Mechanical mmmfor hot and chilled wm rare not used. Hyumniuheat pump systems connected ma q K~ common w o,loop meet heat oHemionand heat addition requirements, SYSTEM —SPECIFIC ss wac anioa| w/ouo,economizer apeoinwgunxydmni0000n 8 r and Uum|d| fimuionuyotdesigned uumu|ns^in ng — inside humidity uu^35A» F clowpoin\iian economizer isrequired. SYSTEM os o. 1.1 Mechanical HvxCfan aysmmnange gnoo"umonauum l SPECIFIC exceed allowable fan myumm motornamop| mohp SYSTEM —SPECIFIC 6.53.1.2 Mechanical nrfan system bhp. nvxCfan motors not larger than the first available u 0 motor greater nvAC s.sa/ Mechanical Exhaust air energy recovery onsystems meeting K K K U Tables O.5.h.1'1.and 6.5. 6,1'%. SYSTEM —SPECIFIC 7.42 Weoxun|mg Service water heating equipment meets efficiency 0 mq"/mmonm. Gv8rEM_8PEC|r|C 7a.2 Mechanical Semivawmo,xea ngequipment used ^o o K U K:U with equipment requirements. nuv|ouimn 5.8.1.2 Envelope Abovn~Q dewonmau|ahuninutaUedper K munukmmm E` uinmmohunu. Insulation 5.0.12 Envelope Floor insulation installed per manufauumrAEnwo instructions. Gonunio /0.4.3 Mechanical Elevators are designed with the proper|ightinq. 0 ventilation power, and standby mode. SYSTEM —SPECIFIC 6.4. 1.1.641-7a Mechanical Hem Rejection Equipment:Minimum Efficiency r 7 Requirement Table SYSTEM —SPECIFIC 84.1.1. 6.8. 1-7b Mechanical Heat Equipment: Minimum Efficiency Requirement Tahle0.V.1-7 SYSTEM —SPECIFIC 6.411. 6.8.1'7c Mechanical Heat Rejection Equipment: Minimum Efficiency En*rgyGaugeSummK@FlaKCnm-2O17,TAM 2O17-1.OCompliant Software. Effective Date: Dec 31.2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90. 1-2013 - Energy CostBudget Option SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7d Mechanical Heat Rejection Equipment: Minimum Efficiency 13 tv El SYSTEM —SPECIFIC 6.5,5,3 Mechanical Requirement Table 6.8.1-7 Centrifugal tan open -circuit cooling towers having combined rated capacity >= 1100 gpm meets minimum efficiency requirement: Table 6.8.1-7 SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7e Mechanical Heat Rejection Equipment: Minimum Efficiency SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7f Mechanical Heat Rejection Equipment: Minimum Efficiency SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7g Mechanical Requirement Table 6.8.1-7 Heat Rejection Equipment: Minimum Efficiency Requirement Table 6.8.1-7. SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7h Mechanical Heat Rejection Equipment: Minimum Efficiency Requirement Table 6.8.1-7 SYSTEM —SPECIFIC 6.4.1.1, 6.8.1-7i Mechanical Heat Rejection Equipment: Minimum Efficiency 13 16 13 SYSTEM —SPECIFIC 7.5.3 Mechanical Requirement Table 6.8.1-7 Gas -fired water -heating equipment installed in 13 13 new buildings: where a singular piece of the entire building, thermal efficiency must be >= 90 Et. Where multiple pieces of equipment serve the building with combined rating input -capacity -weighted -average thermal efficiency , thermal efficiency must be >= 90 Et. Exclude input rating of equipment in individual dwelling units and equipment <= 100 kBtu/h. Plan Review 422.5.31n.5J Envelope Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Plan Review *.2.0.4.2.1. Mechanical Plana specifications, and/or calculations 13 13 0.2 all information with which compliance can »e determined for the mechanical systems and equipment anddocument where exceptions mthe standard are claimed. Load calculations per acceptable engineering standards and handbooks. Plan Review 4.2.2, 7.7.1, 10.4.2 Mechanical Plans, specifications, and/or calculations provide all i nnnaUon which compnoncmcan Uo determined for the service water heating systems and equipment and document where exceptions tothe standard are claimed. Hot water system sized per manufacturer's sizing guide. Plan Review 4.2.2.8.4.1.1. Project Plans, specifications, and/or calculations provide 8. 4.1.2.8.7 all i onna on^which nom iununcan be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized ioaccordance with approved plans and branch circuits sized for maximum drop o/3%. Plan Review 4.22.8.4.3.97 Interior Lighting Plans, specifications, and/or calculations provide uUwithwhichoum | i be determined for the interior lighting and electrical systems and equipment and document where exceptions mthe standard are claimed. Information provided should include interior lighting power calculations, n4bulbs and ballasts, transformers and control devices. Plan Review 87 Exterior Lighting Plans, specifications, and/or calculations provide with determined for the exterior lighting and electrical systems and equipment and document wham exceptions \othe standard are claimed. Information provided should include exterior lighting power calculations, o4bulbs and ballasts, transformers and control devices. EnergyGauge Summit@ Fla/Com-2017.TAM 2017-1.0 Compliant Software. Effective Date: Dec 31.2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy CostBudget Option 4/9/2018 Page 9of|5 Insulation 5.8.1.7.3 Envelope Insulation in contact with the ground has <=0.3% water absorption rate per ASTM C272. Air Leakage 5.4.14 Envelope Vestibules are installed where building entrances 11 1:1 0 separate conditioned space from the exterior, and meet exterior envelope requirements. Doors have self -closing devices, and are >=7 It apart (>= 16 It apart for adjoinging floor area >= 40000 sq.ft.), Vestibule floor area <=7 50 sq.ft. or 2 percent of the adjoining conditioned floor area. HVAC 6.4.3.4.4 Mechanical Ventilation fans >0.75 hp have automatic controls 0 1:1 to shut off fan when not required. HVAC 6.4.3.8 Mechanical Demand control ventilation provided for spaces 500 U and >25 people/1 000 112 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. HVAC 6.4.4.1.4 Mechanical Thermally ineffective panel surfaces of sensible 13 heating panels have insulation >= R-3.5. HVAC 6.5.2.3 Mechanical Dehumidification controls provided to prevent 11 reheating, recooling, mixing of hot and cold airstreams or concurrent heating and cooling of the same airstream. SYSTEM —SPECIFIC 6.5.3.1.3 Mechanical Fans have efficiency grade (FEG) .= 67. The total0 efficiency of the fan at the design point of operation <= 15% of maximum total efficiency of the fan. SYSTEM —SPECIFIC 6.5.3.5 Mechanical Motors for fans >= 1/12 hp and < 1 hp are 1:1 0 electronically -commutated motors or have a minimum motor efficiency of 70%. These motors are also speed adjustable for either balancing or remote control. SYSTEM 6.4.3.10 Mechanical DDC system installed and capable of providingSPECIFIC control logic including monitoring zone and system demand for fan pressure, pump pressure, heating, and cooling; transferring zone and system demand information from zones to air distribution system controllers and from air distribution systems to heating and cooling plant controllers: automatically detecting and alerting system operator when zones and systems excessively drive the reset logic; allow operator removal of zone(s) from the reset algorithm; AND capable of trending and graphically displaying input and output points. SYSTEM —SPECIFIC 6.5.3.2.3 Mechanical Reset static pressure setpoint for DDC controlled 1:1 VAV boxes reporting to central controller based on the zones requiring the most pressure. Controls provide: zone damper monitoring or indicator of static pressure need; autodetection, alarm, and operator override of zones excessively triggering reset logic. SYSTEM —SPECIFIC 6.5.3.3 Mechanical Multiple zone VAV systems with DDC of individual 3 zone boxes have static pressure setpoint reset controls. SYSTEM —SPECIFIC 6.5.3.4 Mechanical Multiple zone HVAC systems have supply air temperature reset controls. SYSTEM —SPECIFIC 6,54.1 Mechanical System turndown requirement met through 13 13 1:1 multiple single -input boilers, one or more modulating boilers, or a combination of single -input and modulating boilers. Boiler input between 1.0 MBtu/h and 5 MBtu/h has 3:1 turndown ratio, boiler input between 5.0 MBtu/h and 10 MBtu/h has 4:1 turndown ratio, boiler input > 10.0 MBtu/h has 5:1 turndown ratio. HVAC 6.5.4.2 Mechanical HVAC pumping systems >10 hp designed for 13 variable fluid flow. SYSTEM —SPECIFIC 6.5.43, 6.5.43.1, Mechanical Fluid flow shutdown in pumping systems to 1:1 6.5.4.3.2 multiple chillers or boilers when systems are shut down. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Option 4/9/2018 Page 10 of 15 SYSTEM 6.5.4.4 Mechanical Temperature reset by representative building 13 SPECIFIC loads in pumping systems >10 hp for chiller and boiler systems >300,000 Btu/h. SYSTEM —SPECIFIC 6.5.4.5.2 Mechanical Hydronic heat pumps and water-cooled unitary air 013 conditioners with pump systems >5 hp have controls or devices to reduce pump motor demand. SYSTEM —SPECIFIC 6.5.4.6 Mechanical Chilled -water and condenser water piping sized according to design flow rate and total annual hours of operation (Table 6.5.4.6). SYSTEM 6.5.5.2.1 Mechanical Fan systems with motors >=7.5 hp associatedSPECIFIC with heat rejection equipment to have capability to operate at 2/3 of full -speed and auto speed controls to control the leaving fluid temperature or condensing temp/pressure of heat rejection device. SYSTEM —SPECIFIC 6.5.5.2.2 Mechanical Multicell heat rejection equipment with 110 variable -speed fan drives installed that operate the maximum number of fans allowed that comply with manufacturers specs and control all fans to the same fan speed required for the instantaneous cooling duty. SYSTEM —SPECIFIC 6.5.5.2.3 Mechanical NA HVAC 6.5.7.1.1 Mechanical Kitchen hoods >5,000 cfm have make up air 13 11 50% of exhaust air volume. HVAC 6.5.7.1.1 Mechanical Kitchen hoods >5,000 cfm have make up air 50% of exhaust air volume. SYSTEM 6.5.7.1.2 Mechanical Conditioned supply air to space with a kitchenSPECIFIC hood shall not exceed the greater of a) supply flow required to meet space heating or cooling, or b) hood exhaust flow minus the available air transfer from available spaces. SYSTEM —SPECIFIC 6.5.7.1.3 Mechanical Kitchen hoods with a total exhaust airflow rate 5000 cfm meet replacement air, ventilation system, or energy recovery requirements shown in Table 6.5.7.1.3. SYSTEM —SPECIFIC 6.5.7.1.4 Mechanical Kitchen hoods with a total exhaust airflow rate 5000 cfm meet replacement air, ventilation system, or energy recovery requirements. HVAC 6.5.7.2 Mechanical Fume hoods exhaust systems >=5,000 cfm have VAV hood exhaust and supply systems, direct make-up air or heat recovery. HVAC 6.5.8.1 Mechanical Unenclosed spaces that are heated use only radiant heat. SYSTEM 7.5.1 Mechanical Combined space and water heating system not ElSPECIFIC allowed unless standby loss less than calculated maximum. AHJ has approved or combined connected load <150 kBtu/h. Controls 8.4.2 Project At least 50% of all 125 volt 15- and 20-Amp receptacles are controlled by an automatic control device. Other Equipment 10.4.1 Mechanical Electric motors meet requirements where 13 0 applicable. HVAC 6.4.3.3.2 Mechanical Setback controls allow automatic restart and 11 temporary operation as required for maintenance. SYSTEM —SPECIFIC 6.4.3.3.3 Mechanical Systems with setback controls and DDC include optimum start controls. Optimum start algorithm considers mass radiant slab floor temperature. SYSTEM —SPECIFIC 6.4.3.3.4 Mechanical Zone isolation devices and controls. Wattage 9.4.2 Exterior Lighting Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Option 4/9/2018 Page I I of 15 Insulation 5. 8. 1 .7 Envelope Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. HVAC 6.4.3.7 Mechanical Freeze protection and snow/ice melting system sensors for future connection to controls, Air Leakage 5.4.3.1 Envelope Continuous air barrier is wrapped, sealed, 1:3 11 1:1 caulked, gasketed, and/or taped in an approved manner, except in serniheated spaces in climate zones 1-6. Air Leakage 5.4.12 Envelope Factory -built and site -assembled fenestration and doors are labeled or certified as meeting air leakage requirements. Fenestration 5.8.2-1, 5.8.2.3, Envelope Fenestration products rated (11-factor, SHGC, and 0 1:3 0 5.82.4, 5.8.2.5 VT) in accordance with NFRC or energy code defaults are used. Fenestration 5.8.2.2 Envelope Fenestration and door products are labeled, or a signed and dated certificate listing the U-factor, SHGC, VT, and air leakage rate has been provided by the manufacturer. SYSTEM —SPECIFIC 7.4.4.1 Mechanical Temperature controls installed on service water 0 0 0 heating systems (<=120AOF to maximum temperature for intended use). SYSTEM —SPECIFIC 7.4,4.2 Mechanical Automatic time switches installed to automatically 11 11 0 switch off the recirculating hot-water system or heat trace. SYSTEM —SPECIFIC 7.4.6 Mechanical Heat traps installed on non -circulating storage water tanks. HVAC 6.4.1,4, 6.4.1.5 Mechanical HVAC equipment efficiency verified. Non-NAECA HVAC equipment labeled as meeting 90.1. SYSTEM —SPECIFIC 6.4.1.5.2 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. 13 0 13 labeled for replacement only. HVAC 6.4.3.4.1 Mechanical Stair and elevator shaft vents have motorized 1:1 0 1:1 dampers that automatically close. HVAC 6.4.3.4.2, 6.4.3.4.3 Mechanical Outdoor air and exhaust systems have motorized 1:1 E] 1:1 dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. HVAC 6.4.3,4.5 Mechanical Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. HVAC 6.5.3.2.1 Mechanical DX cooling systems >= 75 kBtu/h (>= 65 kBtu/h effective 1/2016) and chilled -water and evaporative cooling fan motor hp >= AIA designed to vary indoor fan airflow as a function of load and comply with operational requirements. HVAC 6.4.4.1.1 Mechanical Insulation exposed to weather protected from damage. Insulation outside of the conditioned space and associated with cooling systems is vapor retardant. HVAC 6.4.4.1.2 Mechanical HVAC ducts and plenums insulated. Where ducts or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. HVAC 6.4.4.1.3 Mechanical HVAC piping insulation thickness. 'Where piping 0 1:1 El is installed in or under a slab, verification may need to occur during Foundation Inspection, HVAC 6.4.4.2,1 Mechanical Ducts and plenums sealed based on static 1:1 1:3 1:1 pressure and location. SYSTEM —SPECIFIC 6,4.4.2.2 Mechanical Ductwork operating >3 in. water column requires air leakage testing. SYSTEM —SPECIFIC 6.5.2.1 Mechanical Zone controls can limit simultaneous heating and cooling and sequence heating and cooling to each SYSTEM —SPECIFIC 6.52.2.2 Mechanical zone. Two -pipe hydronic systems using a common 0 11 1:1 distribution system have controls to allow a deadband >=15 A2F, allow operation in one mode for at least 4 hrs before changeover, and have rest controls to limit heating and cooling supply temperature to <=30 A2F. EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Option 4/9/2018 Page 12 of 15 HVAC 6.5.2Al Mechanical Humidifiers with airstream mounted preheating 1:3 1] 13 jackets have preheat auto -shutoff value set to activate when humidification is not required. HVAC 6.5.2.4.2 Mechanical Humidification system dispersion tube hot surfaces in the airstreams of ducts or air -handling units insulated >= R-0.5. SYSTEM -SPECIFIC 6.53,22 Mechanical VAV fans have static pressure sensors positioned 1:1 13 SYSTEM -SPECIFIC 6.5.4.5.1 Mechanical Two -position automatic valve interlocked to shut 0 1:1 1:1 off water flow when hydronic heat pump with pumping system > 10 hp is off. SYSTEM -SPECIFIC 6.5.6,2 Mechanical Condenser heat recovery system that can heat 13 1-1 water to 85 kF or provide 60% of peak heat rejection is installed for preheating of service hot HVAC 6.5.7.1.5 Mechanical Approved field test used to evaluate design air 1:1 1:3 1:1 flow rates and demonstrate proper capture and containment of kitchen exhaust systems. SYSTEM -SPECIFIC 6.5.9 Mechanical Hot gas bypass limited to: 130 HVAC 6.43.9 Mechanical Heating for vestibules and air curtains include automatic controls that shut off the heating system when outdoor air temperatures > 45F. Vestibule heating systems controlled by a thermostat in the vestibule with setpoint <= 60F. Controls 6.5.10 Mechanical Doors separating conditioned space from the 11 13 outdoors have controls that disable/reset heating and cooling system when open. Controls 9.4.1.1 Interior Lighting Automatic control requirements prescribed in 13 13 13 Table 9.6.1, for the appropriate space type, are installed. Mandatory lighting controls (labeled as REQ') and optional choice controls (labeled as ADD1'and'ADD2') are implemented. Controls 9.4.1.1 Interior Lighting Independent lighting controls installed per 13 13 13 approved lighting plans and all manual controls readily accessible and visible to occupants, Controls 9.4,11.2 Interior Lighting Parking garage lighting is equipped with required 13 13 lighting controls and daylight transition zone Controls 9,4. 1.1 f Interior Lighting Daylight areas under skylights and roof monitors 0 1:1 11 that have more than 150 W combined input power for general lighting are controlled by Controls 9.4.1.4 Exterior Lighting Automatic lighting controls for exterior lighting Controls 9.4.1.3 Interior Lighting Separate lighting control devices for specific uses 1:1 13 13 installed per approved lighting plans. Wattage 9.6.2 Interior Lighting Additional interior lighting power allowed for 0 1:1 El special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Wattage 96.4 Interior Lighting Where space LPD requirements are adjusted 0 0 13 based on room cavity ratios, dimensions are consistent with approved plans. Insulation 553.1 Envelope Roof R-value. For some ceiling systems, El 0 0 verification may need to occur during Framing Insulation 5.8.1.2, 58.1.3 Envelope Roof insulation installed per manufacturer CTMS instructions. Blown or poured loose -fill insulation is installed only where the roof slope is <=3 in 12. Insulation 5.8.1.1 Envelope Building envelope insulation is labeled with R-value or insulation certificate has been provided listing R-value and other relevant data. Insulation 5.8.1.9 Envelope Building envelope insulation extends over the full 0 0 1:1 area of the component at the proposed rated R or U value. Insulation 5.8.1.4 Envelope Eaves are baffled to deflect air to above the Insulation 5.8.1.5 Envelope Insulation is installed in substantial contact with the inside surface separating conditioned space from unconditional space. EnergyGauge Summit@Ra/Com-2017. TAM 2017-1 Compliant Software. Effective Date: Dec 31.017 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90,11-2013 - Energy CostBudget Option 4/9/2018 9ugc 13uf|5 Insulation 5.8.1.6 Envelope Recessed equipment installed in building envelope assemblies does not compress the adjacent insulation. Insulation 5.8.1.7.1 Envelope Attics and mechanical rooms have insulation 1:1 0 1:1 protected where adjacent to attic or equipment Insulation 5.8.1.7.2 Envelope Foundation vents do not interfere with insulation, 1:1 0 1:1 Insulation 5.8.1.8 Envelope Insulation intended to meet the roof insulation 0 1:1 0 requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. SYSTEM —SPECIFIC 6.4.3.1.1 Mechanical Heating and cooling to each zone is controlled by a thermostat control. HVAC 6.4.3.1.2 Mechanical Thermostatic controls have a 5 AOF deadband. HVAC 6.4.3.2 Mechanical Temperature controls have setpoint overlap 1:1 0 1:1 HVAC 6.4.3.3.1 Mechanical HVAC systems equipped with at least one 1:1 0 0 automatic shutdown control. SYSTEM —SPECIFIC 6.4.3.5 Mechanical Heat pump controls prevent supplemental electric E] 1:1 1:1 resistance heat from coming on when not needed. HVAC 6.4.3.6 Mechanical When humidification and dehumidification are 0 1:1 1:1 provided to a zone, simultaneous operation is prohibited. Humidity control prohibits the use of fossil fuel or electricity to produce RH > 30% in the warmest zone humidified and RH < 60% in the coldest zone dehumidified. HVAC 6.4.3.6 Mechanical When humidification and dehumidification are 1:3 1:1 11 provided to a zone, simultaneous operation is prohibited. Humidity control prohibits the use of fossil fuel or electricity to produce RH > 30% in the warmest zone humidified and RH < 60% in the coldest zone dehumidified, SYSTEM —SPECIFIC 7.4.4.3 Mechanical Public lavatory faucet water temperature <=1 1 OA oF SYSTEM—SPECIFIC 7.4.4.4 Mechanical Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank. SYSTEM —SPECIFIC 7.4.51 Mechanical Pool heaters are equipped with on/off switch and no continuously burning pilot light. SYSTEM —SPECIFIC 7.4.5.2 Mechanical Pool covers are provided for heated pools and pools heated to >90A*F have a cover >=R-12. SYSTEM —SPECIFIC 7.4,53 Mechanical Time switches are installed on all pool heaters El 1:1 El and pumps. Wattage 9.2.2.3 Interior Lighting Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. SYSTEM —SPECIFIC 7.4.3 Mechanical All piping in circulating system insulated 11 1:3 11 SYSTEM —SPECIFIC 7.4.3 Mechanical First 8 ft of outlet piping is insulated 1:1 11 1:1 SYSTEM —SPECIFIC 7.43 Mechanical All heat traced or externally heated piping 1:3 1:1 11 insulated Plan Review 6.7.2.4 Mechanical 'Detailed instructions for HVAC systems commissioning included on the plans or specifications for projects >=50,000 ft2. Plan Review 6.7.2.4 Mechanical Detailed instructions for HVAC systems commissioning included on the plans or specifications for projects >=50,000 U. Post Construction 6.7.2.1 Mechanical Furnished HVAC as -built drawings submitted 11 E] 1:1 within 90 days of system acceptance, EnergyGaugeSummd@Ro/Com-2O17.TAM 2U17-1.0Compliant Software. Effective Date: Dec 31.2U17 Florida Building Code, Sixth Edition (281T)'Energy Conservation ASHRAE8O1-2O13'Energy Cost Budget Option Post Construction 6.7.2.2 Mechanical Furnished O&M manuals for HVAC systems within 8Odays ofsystem acceptance. Post Construction Conotrvcion 67.2.3 Mechanical Anair and/or hydmnicsystem balancing reportis provided for HVACsystems serving zones `5.00V n^v,conditioned area. HVAC 6I2.4 Mechanical MVACcontrol systems have been tested to ensure pmpn,opemVon.oa\ibnmionand adjustment o|controls. Post Construction oJA Interior Lighting Furnished as -built drawings for electric power uyom"system Post Cunmmuhun 8J.2 Interior Lighting Furnished O&M instructions for systems and K~ equipment mthe building owner o,douign ug representative. EnorgyGaugeGummd@ FlaX}nm-2U1lTAM 2O17-1. 0Compliant Software, Effective Date: Dec 31.2O17 Florida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy CostBudget Option 4/9/2018 Page l5o[|5 W CL EnergyGauge Summit® v6.00 INPUT DATA REPORT Proiect Information Project Name: JKLLC Orientation: 0 Deg Clockwise. Walls & Windows be rotated accordinglyProjectTitle: J&K LLC Building B Interior Office Build -Out Building Type: Office Address: 3400 St. John's Parkway Building Classification: Renovation to existing building Units 2 & 3 State: FL No.of Stories: 1 Zip: 32771 GrossArea: 868 SF Owner: Cox Construction and Development Zones No Acronym Description Type Area Multiplier Total Area sf] [sf] I PrOZo I Zone I CONDITIONED 867.8 1 867.8 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume ft] [ft] [ft] plier [sf] [cf] 4/412018 EnergyGauge Summit® v6.00 In Zone: ProZol I Pr0Zo 1 Sp 1 ZoOSP I Office - Enclosed 24.50 35.42 10.00 1 867.8 867T9 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: ProZol In Space: Pr0ZolSpl I Compact Fluorescent General Lighting 5 40 200 Manual On/Off 4 2 Compact Fluorescent General Lighting 2 20 40 Manual On/Off 2 Walls (Walls will be rotated clockwise by building rotation value) No Description Type Width H (Effec) Multi Area Orientation Conductance Heat Dens. R-Value ft] ft] plier [sf] [Btu/hr. sf. F] Capacity lb/cf] [h.sf.FBtu] Btu/sf.F] In Zone: ProZol I PrOZo I Wa I 5/8" stucco 24.80 10.00 1 248.0 North 0.2067 5.731 34.65 4.8 8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo I Wa2 5/8" stucco 24.80 10.00 1 248.0 South 0.2067 5.731 34.65 4.8 8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 PrOZo I Wa3 5/8" stucco 35.00 10.00 1 350.0 East 0.2067 5.731 34.65 4.8 8"CMU/3/4"ISO BTWN24°oc/.5" Gyp 4 PrOZo IWa4 5/8" stucco 38.20 10.00 1 382.0 West 0.2067 5.731 34.65 4.8 8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 4/9/2018 EnergyGauge Summit® v6.00 Windows (Windows will be rotated clockwise by building rotation value) No Description Orientation Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area Btu/hr sf F] ft] [ft] plier [sf] In Zone: PrOZol In Wall: PrOZo I Wa2 I PrOZo I Wa2Wi I South No 0.9000 0.68 0.66 5.30 5.00 2 53.0 2 PrOZo I Wa2Wi I South No 0.9000 0.68 0.66 3.00 8.00 1 24.0 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value ft] [ft] plier sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] h.sf.F/Btu] In Zone: In Wall: Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value Iftl [ft] plier [sf] deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] h.sf.F/Btu] In Zone: PrOZot I PrOZo I Rf I Mtl Bldg Roof/R- 19 35.42 24.50 1 867.8 0.00 0.0492 1.34 9A9 20.3 Batt Skylights No Description Type U SHGC VisXrans W H (Effec) Multiplier Area Total Area Btu/hr sf F] ft] [ft] [Sf] IS11 In Zone: In Roof: I F-1 4/9/2018 EnergyGauge Sununit@ v6.00 No Description In Zone: PrOZol I PrOZo I Fl I Type I ft. soil, concrete floor, carpet and rubber pad I PrOSyl System 1 I Cooling System 2 Heating System 3 Air Handling System -Supply Equipment W-Heater Description Category Floors Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value ft] [ft] plier [sf] [Btulhr. sf. F] [Btu/sf. F] [lb/cf] Nsff/Btul 35.42 24.50 1 867.8 0.2681 34.00 113.33 3.73 Systems Constant Volume Air Cooled Split System < 65000 Btu/hr Capacity Efficiency IPLv 35000.00 14.00 8.00 2729T00 1.00 1200.00 0.80 1 Water Heaters Capacit3Cap.Unit UP Rt. Inst.No Eff. Efficiency No. Of Units I Loss IPLV 4/9/2018 EnergyGauge Summit@ v6.00 4 J EA -Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Lun-finaire [sf/ft/No] Control Type Wattage W] El Piping No Type Operating Insulation Temperature Conductivity F] Btu-in/h.sf.Fl Nomonal pipe Diameter in] Insulation Is Runout? Thickness in] E3 Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance Btu/h.sf.F] ASHULDbICIrM User Defined 2 0.9000 0.6800 0.6600 t1-0th frm Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density Specififfleat Used [hsf.F/Btu] [ft] Btu/lLft.F] ib/cf] Btu/ib.F] 18 MatII8/ i Y F OR PLAS No 0.4533 0.041/ 0.0920 50.00 0. 000 Li BOARD,1/21N 7 atl 178 CARPET W/RUBBER PAD Yes 1.2300 265 Mat,1265 Soil, I ft No 10000 1.0000 0.5000 100.00 0.2000 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 4/9/2018 EnergyGauge Summit® v6.00 5 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16,00 0.2000 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 block 269 Matl269 75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 23 atl23 6 in. Insulation No 20.0000 0.5000 0D250 5.70 0.2000 94 MatJ94 BUILT-UP ROOFING, 3/81N No 0.3366 0.0313 0.0930 70.00 0.3500 Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1011 5/8" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8 BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. Factor 1 268 0.625" stucco 0.0521 0.000 2 42 8 in. Lightweight concrete block 0.6670 0.000 3 269 75" ISO BTWN24" oc 0.0625 0.000 4 187 GYP OR PLAS BOARD, 1/21N 0.0417 0.000 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] Btu/sf.F] lb/cf] [h.sf.F/Btu] 1056 MtI Bldg Roof/R-19 Batt No No Layer Material Material No. 1 94 BUILT-UP ROOFING, 3/81N 2 23 6 in. Insulation 0.05 1.34 9.49 20.3 Thickness Framing ft] Factor 0.0313 0.000 0.5000 0.000 4/9/2018 EnergyGauge Summit® v6.00 6 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] lb/cf] [hsf.F/Btu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 027 34.00 113.33 3.7 Layer Material Material Thickness Framing No. ft] Factor 1 265 Soil, I ft 1.0000 0.000 2 48 6 in. Heavyweight concrete 0.5000 0.000 3 178 CARPET W/RUBBER PAD 0.000 4/9/2018 EnergyGauge Summit® v6.00 7 C CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application ',\o: Bldg, Permit # 18-1985 Documented Construction Value: S 19-,Q,/t5V0 4((0, `350 Job Address: 3440 St. John's Pkwy. Suite #1020 Historic District: Yes E No Pat -eel ID: 26-19-30-5AE-2900-0000 Residential F] Commercial Type of Work: Neer V AdditionEl Alteration 11 Repair 0 DemoEl Change of Use[] 'Move Description of Work: Installation of electrical for tenant space per electrical drawings. Plan RevieNv Contact Person: Nicole Fusco Phone, 877- 906-1113 ex. 1257 Fax: 407-585-1002 Title: Commercial Admin. Email: Commercial@Stradaelectric. com Property Owner Information Name J & K Sanford Phone: 877-906-1113 ex. 1257 Street: 3400 St. Johns Pkwy. Resident of property? CitN7, State Zip: Sanford, FL 32771 Contractor Information Name Strada Electric & Security, Inc. Phone: 877-906-1113 Street: 3400 St. Johns Pkwy. Fax: 407-585-1002 City, State Zip: Sanford, FL 32771 State License No.: EC13003715 Name Street: City, St, Zip: Bonding Company Address: Architect/ Engineer Information Phone: Fax: E- mail: Mortgage Lender: L' Address: W kR_ NING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN I OUR PAYING TWICE FOR IMPROVEMENTS TO VOIUR PROPERTY. A NOTICE OF CONINTENCENIENT MUST BE RECORDED AND POSTED ON THE; JOB SITE BEFORE THE FIRST INSPECTION. IF YOU, INTENT) TO OBTAIN FIN,A, NCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, A eLls, pools, furnaces, boilers, heaters, tanks, and air conditioners. etc. FBC 105. 3 Shall be inscribed with the date of application and the code in effect as of that date: 511, Edition (2014) Florida Building Code Revised: June 30, 2015 pennit i"'PP11("ation CANIM NOTICE: In addition to the requirements of this permit. there may be additional restrictions applicable to this property that may be found in the ptibk, T-M-vds of this count%,. and there may be additional permit,, required from other governmental entities such as water vnanagement districts, state agencies, or federal agencies. 4:11 - SM"",unit is verification that I will notify the owner of the nequil-ements of Florida Lien Law, FS 713, td requires payment of a plan review fee at the A copy of the executed contract is required 1 ondm .v oahnflate a plan review charge and will be considered the e',tir at,-d c,,,,'rruction value ofthe job at the time of submittal. corrs" nuo n value \Nil] be figured based on the current _ICE n Table in effect at the time the permit is issued, in c'-al ordinance. ShouTd calculated charges figurdd* thr, ex QOtdd contract exceed the actual construction value, pied t o your permit fees when the permit is issued. 0NV'%.' EWXAFF1DAN71T: I certify that all of the foreg6 b clan, -in6qmpliance with all applicable [a-,N,s regulatin S Matur n owner ignaturoOwnerAgentDate Joseph Strada Print Ctm)u Azew's Name Signature of Notary -State of Ronda Date Owner' Agent is Personally Known to Me or Produced ID TyI)e of ID ift , 11 ernation is accurate and that all Nvork Neill g co tradition and zoning. Sim lKuof Contmctor Agent Date Joseph Strada Print Contractor; Agent Name SkgT,,atureofNotary- State ofFl(,iida Date Contractor, Agent Is Personally, Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building C El Electrical [] Mechanical7Plumbin,7 GasF Roof Construction Type- Totat Sq Ft of Bldg: M Occupancy Use: Min. Occupancy Load: Ne-vv Construction: Electric - # of Amps Fire Sprinkler Permit: Yes 7 No It of Heads A,PPROVALS: ZONING: UTILITIES: ENGINEERING: FIRE: COTNOIENTS: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes [] NoE] WASTE WATER: BUILDING: Revised: June 30. 2915 Pe~ ma Appticatkon CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application Na: Documented Construction Value: $ Job Address: S(L Jqt-i" 4-4,24 Historic District: Yes 0 No F] Parcel ID:,2 6 j i ResidentialEl Commercial Vj Type of Work: New[] Addition El AlEl Alteration RepairElDemoEl Change of UseE] Move El Description of Work: Plan Review Contact Person: " Title: Tit, Phone: Fax: Email: Property Owner Information Name Phone: Street: Resident of property?. City, State Zip: Contractor Information 2 Phone: Street: A) L_ i qo(J4b (k") Fax: A, State License No.: C- City, State Zip 4Architect/Engineer Information Name: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E- mail: Mortgage Lender: Address. - WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate pertnit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: S'h Edition (2014) Florida Building Code Revised: June 30, 2015 flenint Application r xr9vi "Jy Re. "orrl_Q and 99A-4111AI Proper ty Addt ess: W00 ;>T JOHII 1' V"Y „`.,i,.i I O P[r Ft__5.'Ft1 Parcel Information Value Summary Parcel 26-19-30-5AE-2900-0000 2018 Working 2017 Certified Values Values Owner (s) ' J S K SANFORD LLC i Valuation Method CostlMarket Cost/Market Property Address 3400 ST JOHNS PKWY SANFORD, FL 32771 Number of Buildings 0 0 Mailing 215 CLERMONT RD LAKE MARY, FL 32746 Depreciated Bldg Value Subdivision Name LilrI11, tit Ni Depreciated EXFT Value Tax Distiict S1-SANFORD Land Value {Market) 869,348 772,754 DOR Use Code 40-VAC INDUSTRIAL GENERAL Land Value Ag Exemptions s. 'A., r',1 V flm-' ° 869.343 772.754 Potl ability Adj Save Our Homes Ad) 0 0 1 f ` Amendment i A.dj 19,319 0 I _ P&Cx Adj 0 0 Assessed Value 850029 772,754 i h J'ax AtnountwitNOul S0H $f4,711L39 1j' i :} 1 ill ttf U it $1<1,714..39 la.,tl laY SaVe Our Homes Savings 0.00 Okirdy Does NOT INCLUDE Nan Ad Valorem Assessments Legal Description BLK 29 (t_ESS RD) M M SMITHS SUED PB 1 PC, 55 Taxes Taxing Authonty..... Assessment Value... Exempt Values.. Taxat) e Value. County Genetal Fund 85w)29 0 850,029 Schools 669,348 0 869,348 City Sanford 85Q029 0 850,029 SJWM(Sainl Johns Water Management) bW029 0 850,029 County Bonds 850.029 0 860,029 Sales Description Date Book Page Amount Qualified Vactlrnp VVARRANIY(TEED 3/112016 W£s. 2 C,':3 900.000 Yes Vacant PROBATE RECORDS 111t2018 O 'rt'3 100 No Vacant PROBATE RECORDS 511t2009 100 No Vacant PROBATE PFCQRDS 101112007 J "' 100 No Vacant PROBATE RECORDS 6111!2003 100 No Improved WARRANTY DEED 3,1111992 C,t "q 14't? 100 No Improved OUI I CLAIM DEED 1011,1989 i "A 100 No Improved WARRANTY DEED 4t1t1987 100 No Improved WARRANTY DEED 71110986 1 100000 Yes Improved Land Method Frontage Depth Units Units Puce Land Value SQUARE FEET 000 . 000 386377 $3 0G $869.348 Building Information Permits Permit # Deso Iption Agency Amount CO Date hermit Date 00203 BLDG H - 3440 Sr JOHNS PKVW SANFORD 575, x41 V18!2017 00202 BLDO A SANFORD 860,118 215,12018 1(1812017 02448 DFPVIOLISH SFR SANFORD 1.000 8/3112016 01329 REROOF SANFORD 5,000 21X200 r f`atl It d'- tle tr4 l t o R .tcl l th, F n.. i void ly Nop,,ry s m F.>e 00" 1, q,—t Inlit, tf e the U3e <woo r which t1, i[ x-ate t Extra Features Description Year Built UnRs Value New Cost 1 1 r Yit•t I (, hilt(>, PYR1141Tt. c ct 7"Rr1C r()I J00 ADDRESS; TYPE 011 WORI Post this PORI nd approved of tag apyrowd FRS "on t!""FXC)t'ftl RX kCtFXr ttiSl Fi R>, ERGROUND IGH m ROUGH I kL ROOF STORM DRAIN APPPft(>VAD R1.;fF+t "PF:I:r INSPk.C'fCkN STORM DRAIN FINAL GAS LN1f t ti&MVIA 7 thJ!"FX:"Ct:?X m ND? RGROIJND PIPING INAL w._. AL GAS kOITCH-IN' AL GAS FINAL SPEC"CAL. f MISCELLANEOUS PIrrrh` _ dt PRC P t ffF PX TFIk LV1dF{ I lk SISULATION iE DUCT WRAP 41 CHILL WATER ROUGH it', 7°I2AP ROUGH IN iE TRAP FINAL vropop May 08, 2018 A Reference 1029-15 1 DUe Date: 6/'1/20 18 013A I<et) Mullea Fliumbinq 1404 YottdowtSt AEA, Oetatid, F-1- 32724 UG) 738.9209 E- MA41LED Job Name:, COX CONSTRUCTION (lox PO Box 120 iW A00 ST JOHNS VIKWY Clormont, Fl- 34712 UNIT 12 & 13 SANFORD, FL Cox Collst---rucLion 34100 u J' Johns Parkway uni' L E and 13 Sanfc): i.d, Fj All waste and vent" to he I'Vc. 13 a 1-1 i 1 ax I, Y to t' i e i n t (') e X i s t- i 11 g , Vent lAirli roof sealed 1)! others. All wat:el: t,o be ('PV(" Water to t 1.e into existing, We shall f6rrtish and install. the fcd-l(Dwtn( l-' F0-,(-) Ent rada ADA white water. closet 1.-- 2OxJ8 APA villite well. hung lavatory I- Delto, 150'. lavat ury faucet, 1, - Ha 11"IJ, --wrap 1- laundry sink w/fauceL I - Elkav iii, to drinking fountaiii 1. -- Da,, t: ri 2 !) x' ' 2 st.ainles s st eel kitchen sink, T- Delta 440 ),litIche'll sillk faucet, Ccstfcl' t' ttie above. ",36,446.00 Thi,s p.ropo.sal piepared t), Herrow L, I,' c1ba Ken Mullen Plumbing Page 1 of 2 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: $ Job Address: ClQ(;s V V-10 Historic District: YesEl No [I Parcel ID: Cj K_; Residential [j Commercial Zj Type of Work: New[] Addition F1 Alteration 11 RepairEl DemoEl Change of UseD Move El Description of Work: Plan Review Contact Person: Title: Phone: Fax: Email: Property Owner Information Name Phone: Street: -- - --------- Resident of property?: City, State Zip: Contractor Information Name ' P('- P Lrn e: '5 i -2, Street: )`(q VAX: p vorj ,3)/i. sit, Fax: City, Stake Zip: State License No.: Arch itect/Engi neer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF CONITIVIENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN I FINANCING, CONSULTWITH YOUR LENDER OR AN' ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT, Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised; June 30, 2015 Permit Application 11 l Z; t..'f l A ' T' A ^.... G A f 01 A Ken Mt.rl%n PIruM 0g 1404 Yoiktown St ftf, DeLand,, Ft 32724 386) 7349299 info@.)Prostic3e(alLtmbiti9fl.crarrr COX CONST!"?UCTION PO Box 120507 Ir err nnf r-i t'1A r E 9 12-394-6299 352-516-4401 DAVID May 08, 2018 Refer npb #; 1029-1512 ue Oaks: Gltl2018 1E M MED Cox 3400 ST JOHNS PKWY UNITS 3 & 4 SANFORD, FL Cox constrarction 3400 St. d6hns Parkway Unit 3 and 4 Sanfo d, F l . All sanit.alT waste and vent to be PVC. Sanitary to tie into existing. Vent t;h>:u roof sealed by, okhers. All water to he CPVC . Water to tie into existing. Others to At and remove concrete. We shall fyrnish and install thefollowing: 2-` oto Ent =ada AL)A whitewater closets t 20x1. 0 wh,,te ADA Wall hung lavatories 2-Delta 501 lavatory faucets 2-Grid strainers 2 -Handi.- wrTp.a L-Elkay hiplo drinking fountain I-MusLeel7 laundry, sink w/faucet. t;-Dayton 25x 2 sLainles> steel kitchen sink l-Delta 440 kitchen sink faucet Cost for the above $7,985.00 This p opooa1. prepared by Won MerroW GM Prestige Plumbing, LLC dba Ken Mullen Plumbing Page 1 of 2 Ti a . :r,, rotic.rttt Ft4c.crtil_Ctatcf if" ROF,f R I y Parcel: IIi Sq) t ;etl:i Oki t IS Property Address sr'.Ni ,71<(r "i_ Parcel Information Value Summary Parcel 26-19 30-5AE-2900-0000 2018 Vvarking 2017 Certified Values Values Owners) J & K SANFORD LLC Valuation Method Cost/Market Cost/Market Property Address 3400 ST JOHNS PKVW SANFORD, FL 32771 Number of Buildings 0 0 Marling 215 CLERMOH F RD LAKF MARY, FL 32746 Deixeciated E3Idg Value Subdivision Name 1.f17Ia'I N! M Depreciated EXFT Value Tax Distract Si-SAHFORD Land Value (Market) 889,348 772,754 DOR Use Code 40-VAC; INDUSTRIAL GENERAL Land Value Ag Exemptions Jr ,! e! V"Aie 869 348 772,754 t1 Portability Adj Save Out dames Adj 0 0 i Amendment 1 Adj 19,319 80 P&G Adj 0 0 i Assessed Value 850.029 712,754 I ` Tax Amount WJIhQut SOH $14,1H,39 Cri 201 Ta [310 Imt W $14,714.39 r i I", i Save Our Flomes ztu u}tLr Savings $0.00 Does NOT INCLUDE Non Ad Valorem Assessments Legal Description 131,K 29 (LESS RD) M M SMITHS `iUBD P13 1 PG 55 Taxes Taxing Authority Assessment Value Exempt Values Taxable Value County Geneiai Fund 850,029 0 850,029 Schools fI69,348 0 869,348 City Sanford 850,029 0 850,029 SJVVM(Saint Johns Water, Management) 81,50,029 0 850,029 ounty Bonds 850,029 0 850,029 Sales Description Date Book Page Amonitt Qualified Vactlmp WARRANTY DEED 3t1t2016 08o,6 900,000 Yes Vacant PRO6F.TE F2EC;GRDS 1/112016 rT>l3 I 100 No Vacant PROOATE RECORDS 5f1112009 Q='12i i lilt 100 No Vacant Pt C EATt: RECORDS 01:11/2007 tjF 100 No Vacant IIRO13AI E RECORDS 571t2003 011V,30 100 No Improved WARRAN-1Y DEED 3/1/1992 C•1 i<i 1470 100 No Improved QUIT CLAIM DEED 0(1f1989 i i 4 t 100 No Improved WARRANTY DEED 4/111987 1 41 i",I 100 No improved VVARRANT'Y PEED 7/111906 91 17ti£ C344 100 000 Yes Imtxaved Fine! (;:t:,Inprtrable tales Land Method Frontage Depth Units Units Price land Value SQUARE PELT 000 000 386377 $3 00 $869 348 Building Information Permits Permit # Description Agency Amount CC1 Date Permit Date 00203 BLDG R - 3440 ST JOHNS PKWY SANFORD 575.341 1118/2017 00202 13LDG A SANFC7RD 860,118 2l512018 V18t2017 02448 DEMOLISH SFR SANFORD 1,000 V'i1?2016 01329 REPOOF SANFCIRD 5,000 213i20O5 pl-I.t 0111, rip Hale hon tl , S i0 1, C u lty F taperfy At)po"et ¢ ofhc iur data I5 or tllt 'ha. + tt nce I ry a ¢ rlrlft ryfen SP c I . G. the W the Ins tl. ¢trlcl n M-..h thi, nte<i. Extra Features Description Year 13Wt Units Value New Cost UNIVERSAL ENGINEERING SCIENCES Consultants In: seote/hnua Engineering ` Environmental Sciences Geophysical Services ^ Materials Testing ^ Threshold Inspection Building Code Administration, Compliance Inspection mPlan Review - 3532Maggie Blvd, Orlando, FIL 32811 'P:40T.423.06u4 -F:4U7.42a.310G Work Order No. 114538 Inspection Report Project Name: Backyard Address: 344OStJohns PkwySuite 1UOO—Bldg B.#1U08 Sanford, Seminole CouFL32771 Client-, StnadaE| edhc Date: 06/ 22/2018 07: 30am Permit No: 18-1986 Lot No.: Contact: Joe 8tradaat4O7' 421'2522 Scope ofInspection: EXnadaElectric Build Out - CODE 112Final Building Inspection Inspection Type: See Scope Disposition of Inspection: Pass hereby affirm that tothe best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. napochzc Randy Lamb, BN190U UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3632 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Work Order No. 114537 Inspection Rer)ort Project Name: Backyard Date: 06/22/2018 07:30 am Address: 3440 St Johns Pkwy Suite 1008— Bldg B, #1008, Sanford, Permit No: 18-1986 Seminole County, FL 32771 Client: Strada Electric Lot No.: ProjectNo.: 0115.1800209,0000-0115-002 Contact: Joe Strada at 407-421-2522 Scope of Inspection: Strada Electric Build Out - CODE 213 Final Electrical Inspection Inspection Type: See Scope Disposition of Inspection: Pass I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN 1900 UNIVERSAL Z ENGINEERING SCIENCES Consultants In: oeute,xnicmEngineering ^ Environmental Sciences Geophysical Services ^ Materials Testing ^ Threshold Inspection \ ' Building Code Administration, Compliance Inspection ananReview L~ 3s32Maggie Blvd, Orlando, FIL 32811 -P:407.423.0504 -F:407.421310$ Work Order No. 114636 Inspection Report Project Name: Backyard Date: 06/22/2018 07:30am Address: 344UStJohns PkvySuite 1OU8—Bldg B.#1UO8.Sanford, Permit No: 18-1986 Seminole County, FL32771 Client: Stnado Electric Lot No.: PnojeutNo.: 0115.1800209.0000- 0115'002 Contact: Joe Gtnadoed4O7-421-2522 Scope ofInspection: 8trada Electric Build Out-CDDE 313 Final Plumbing Inspection Inspection Type: See Scope Disposition ofInspection: Pass hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN13UO UNIVERSAL ENGINEERING SCIENCES Consultants In: aw^tecxnmuEngineering ^ Environmental Sciences Geophysical Services - Materials Testing - Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532Maggie Blvd, Orlando, pIL 32811 'P:4O7.423.0504 -P:4V7.420.310o Inspection Report Project Name: AutoTex Address: 344USXJohns Pkwy—Bldg B.Sanford, Seminole County, FL 32771 Work Order No. 114535 Date: 06/22/ 2018 07:30am Permit No: 18- 1985 Client: 8badaEleotric Lot No.: ProjeciNo: 8115j800209 0000- 0115-001 Contact: Joe Gtradamt407'421-2522 Scope ofInspection: G1redaElectric Build Out - CODE 41UFinal Mechanical Inspection Inspection Type: See Scope Disposition of Inspection: Pass I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code, Inspector: Randy Lamb, BN1S8O UNIVERSAL ENGINEERING SCIENCES Consultants In: ammcchnica Engineering ^ Environmental Sciences Geophysical Services ^ Materials Testing ^ Threshold Inspection Building Code Administration, Compliance Inspection uPlan Review 3532Maggie Blvd, Orlando, FL 32811 -P:4V7.423.VsV4 'F:4o7.423.3108 Inspection Report Project Name: AutoTex Address: 344OStJohns Pkwy—Bldg B.Sanford, Seminole County, FL 32771 Work Order No. 114534 Permit No: 18- 1985 Date: 08/22/ 2018 07:30am Client: 8tradaEleohic Lot No.: ProjeotNo: O11S18UU2U8.00OO- 0115'OO1 Contact: Joe Stradaat407-421'2S22 Scope ofInspection: EtnadaElectric Build Out - CODE 112Final Building Inspection Inspection Type: See Scope Disposition of Inspection: hereby uffinn that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN1SOO UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering - Environmental Sciences Geophysical Services ^ Materials Testing ^ Threshold Inspection \ , Building Code Administration, Compliance Inspection mPlan Review - 3532Maggie Blvd, Orlando, FIL 32811 -P:407.423.O504 'F:4O7.423.310V Work Order No. 114533 Inspection Report Project Name: AutoTex Date: 06/22/2018 07:30am Address: 344O8tJohns Pkwy—Bldg 8'Sanford, Seminole County, FL Permit No: 18-1985 32771 Client: StnsdaBeotriu Lot No.: Pnojec{No.: 011518002OQ. 00OO-0115-OO1 Contact: Joe Etredaat4O7-421'2522 Scope ofInspection: 8\ nadmElectric Build Out ' CODE 213Final Electrical Inspection Inspection Type: See Scope Disposition of Inspection: heneby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN19OO UNIVERSAL N N N Consultants In: sr^tec^nicalEngineering ^ Environmental Sciences Geophysical Services ^ Materials Testing ^ Threshold Inspection Building Code Administration, Compliance m,pecuovmPlan Review u532Maggie Blvd, Orlando, FL 32811 'P:407.428.0504 -F:407.423.3106 Inspection Report Project Name: AutoTex Address: 3440EKJohns Phwy— Bldg B.Sanford, Seminole County, FL 32771 Work Order No. 114532 Date: 06/22/2018 07:30am Permit No: 18-1985 Client: ShadaElectric Lot No.: P/ojecUNo: O115.180O2OS. OUO0'O115'UO1 Contact: Joe Sbadoed4U7-421-2522 Scope ofInspection: 8madaElectric Build Out - CODE 313Final Plumbing Inspection Inspection Type: See Scope Disposition of Inspection: Pass I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code, Inspector: Randy Lamb, BN1S8U UNIVERSAL tuENGINEERING SCIENCES Consultants In: ueutecxnxa|Engineering ` Environmental Sciences Geophysical Services ^ Materials Testing ^ Threshold Inspection Building Code Administration, Compliance /mpuuo^mPlan Review 3532Maggie Blvd, Orlando, FIL 32811 'P:407.423.0504 -F:407.4o3.310G Work Order No. 11463$ Inspection Report Project Name: Backyard Date: 06/22/2018 07:30am Address: 344OStJohns PkwySuite 1UU8—Bldg 8.#1OU8.Sanford, Permit No: 18-1986 Seminole County, FL32771 Client: StnadaBectr|c Lot No.: PnojeoNo.: 0115.1800209.0000' 0115-802 Contact: Joe St,adaat4O7~421-25Q2 Scope ofInspection: GtnadoElectric Build Out - CODE 410Final Mechanical Inspection Inspection Type: See Scope Dispositionof Inspection: hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections ofthe Florida Building Code. Inspector: Randy Lamb, 8N1QOO Adath, CITY OF QAN-FOW*IIII S,kNFO 11 ------------- ii NfARCDEPAlk'ThifN Building & Fire Prevention Division PERMIT APPLICA TION Application No: 'I ' - ) 2 1 (r Documented Construction Value: $ 1,050.00 Job Address: 3400 St Johns Parkway Unit +2z&=.t3 Historic District: Yes[—INoR] Parcel ID: 26-19-30-5AE-2900-0000 Residential[] Commercial Fype of Work: NewEl AdditionFlAlteration Repair DemoF-]Change of UseElMove n Description of Work: Modify existing fire sprinkler system to accommodate new interior build -out. Plan Review Contact Person: Fred Lupo Phone: 407-328- 1663 Fax: 407-328-4768 Name J & K SANFORD LLC Street: 215 CLERMONT RD Iritle: President Email: flupo@freedomfireprotection.com Property Owner Information City, State Zip: LAKE MARY, FL 32746 Name Phone: Resident of property? : Contractor Information Freedom Fire Protection of Central FL, Inc. Phone 407-328-1663 Street: 601 Central Park Dr. City, State Zip: Sanford, FL 32771 Name: Street: City, St, Zip: Bonding Company: Address: Fax: 407- 328- 4768 State License No.: 22296600012003 Architect/Engineer Information Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6" Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water manage6ent districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713 The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your pet-irut fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Lq- /<t Signature of Owner/Agent Date signature of Contractor/Agent Date Print Owner/Agent's Name Sigilatkire of Notary -State of lorida Date Owner/Agent is Personally Known to Me or Produced ID Type ofID L- r--11AI2 PrIat Ci itra -tor/Age S Iletit' N Signature ol'Notary-State of Florida Date V PAIVIELA J. PREEDOM NOTARY PUBLIC C9 PtWhSTATE OF FLORIDA torg n t is Comrn# FF194479 Contra F- xe0rs y Known to Me or Produced ID _ Type of ID Lk BELOW IS FOR OFFICE USE ONLY Permits Required: Building Q Electrical [I Mechanical [] Plumbing[] Gas[] Roof El Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No F] APPROVALS: ZONING: ENGINEERING: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures of Heads Fire Alarm Permit: Yes [] NoE] UTILITIES: WASTE WATER: FIRE: 5XV Xt BUILDING: Revised: January 1, 2018 Permit Application Jeff&twator Casia Slow CHIEF FINANCIAL OFFICER BUREAU CHIEF J1111115 Haw Keith McCarthyDIVISIONDIRECTOR SAFETY PROGRAM MANAGER FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF'STATE FIRE MARSHAL 200 Best Gaines Street - Tallahassee, Florida 32399-0342 Te1, 850-413-3644 Fax. SW4 10-2467 4 CERTIFICATE OF COMPETENCY OFFICIAL COPY THIS CERTIFIES THAT: Fredric J Lupo 601 Central Park Drive Sanford Fl, 32771 BUSINESS ORGANIZATION: Freedom Fire Protection of Central Fla Inc. Contractor If is limited to the execution of contracts requiring the ability to layout, fabricate, install, inspect, alter, repair, and service water sprinkler systems, water spray systems, foam -water sprinkler systems, foam -water sprayspri systems, standpipes, combination standpipes and sprinkler risers, all piping that is an integral part of the system beginning at the point of service, sprinkler tank heaters, air lines, thermal systems used in connection with sprinklers, and tanks and pumps connected thereto, excluding pre-engineered systems. Issue Date: Type: Class: County: License/Permit 4: Expiration Date. Chief Financial Officer 07/01/2016 07 12 Seminole 222966-0001-2003 06130/2018 rrY r SEMINOLE COUNTY BUSINESS TAX RECEIPT RAY VALDES, SEMINOLE COUNTY TAX COLLECTOR PO Box 630 * Sanford, FL 32772-0630 * Telephone: 407-665-1000 www.seminoletax.org VALID THROUGH 09/30/17 FREEDOM FIRE PROTECTION OF CENTRAL FLORIDA INC 601 CENTRAL PARK DR SANFORD, FL 32771 FRED LUPO (OFFICER) BUSINESS OWNER, PLEASE NOTE THE FOLLOWING: Account #:126842 REGULATED License # - 222966-0001-2003 Qualifier- FRED LUPO SANFORD CITY LICENSE REQUIRED •" o DISPLAY THE ABOVE RECEIPT PROMINENTLY: This Business Tax Receipt shall be displayed conspicuously at the place of business in such a manner that it can be open to the view of the public and subject to inspection by all duty authorized officers of the County. Upon failure to do so, the business shall be subject to the payment of another business tax for the same business or profession o RENEW THIS TAX BEFORE IT EXPIRES: i Pursuant to Florida Statutes, all Business Tax Receipts shall be issued by the Tax Collector beginning July I" of each year, and it shall expire on September 30`s of the succeeding year. Those Business Tax Receipts issued as renewal accounts beginning October I" shall be delinquent and subject to a delinquency penalty of 10% for the month of October, plus an additional 5% penalty for each month of delinquency thereafter until paid; provided that the total penalty shall not exceed 25% of the business tax for the delinquent establishment (Florida Statute FS]205.053 [1]). A 25% penalty shall be imposed on any individual engaged in any new business or profession without first obtaining a Seminole County Business Tax receipt. ([FS] 205.053 [2]) This Business Tax Receipt is only a receipt for business taxes paid. It does not permit the taxpayer to violate any existing regulatory or zoning laws of the state, county, or municipality, nor does it exempt the taxpayer from any other required licenses, registrations, certifications, or permits. Business Tax requirements are subject to legislative change. o REPORT ALL CHANGES: The holder of this Business Tax Receipt is required to report a change in the following: Ownership, Business Location, Mailing Address, or any other information that would alter the status of the current year's taxes. This includes, but is not limited to, the loss of or a change in a State License which was used to qualify for the business activity and/or occupation identified on the current County Business Tax Receipt. If you have any changes to report, contact the Business Tax Department at 407-665-7636. FREEDOM FIRE PROTECTION OF CENTRAL FLORIDA INC 601 CENTRAL PARK DR SANFORD, FL 32771 Country Services Building Casselberry Office Oak Grove Shoppes ShelMar Prof' I Building Commons at Primera I101 E First Street 104 Wilshire Blvd. Unit 1000 995 N SR 434 Suite 505 1490 Swanson Dr #100 845 Primera Blvd Sanford, FL 32771 Casselberry, FL 32707 Altamonte Springs, FL 32714 Oviedo, FL 32765 Lake Mary, FL 32746 Pago I of I Aa... VRQ0 CERTIFICATE OF LIABILITY INSURANCE DATE (MMIDDIYYYYI 08118/2O17 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER, IMPORTANT- If the certificate holder Is an ADDITIONAL INSURED, the pollcy(les) must have ADDITIONAL INSURED provisions or be endorsed. if SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsements . PRODUCER NAMA; Willis of Blorida, Ino. PHONE FAX 1-877-F45-737@ 1-888-467-2376 C/o 26 Century Blvd P,O. Box 305191 E44AIL certificatesewillis-con INSURERS AFFORDING COVERAGE NAIC# Nashville, TN 372305191 USA INSURERA: Evanston Insurance Company 35378 INSURED irreadom Piro Protection of Central Plorida, Inc. 6ol Central Park Dr. INSURER e: National Indemnity Company of the South 42137 INSURERC:.Navigators Insurance Company 42307 INSURER D : Sanford, FL 32771 INSURER E ; INS n%/9:0Ar:PR CERTIFICATE NUMBER! W3290670 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES, LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, TYPE OF INSURANCE A POLICY NVMBER POLICY EFT MM IYY POLICY E P M / Y LIMITS X COMMERCIAL GENERAL LIABILITY EACHOCCVRRENCE f 1,000,000rINTIRCLAIMS -MARE OCCUR PREMI Ea otcunanca S 300, 000 X MED EXP An ens ponon) S _ _, _, 5, 000 nAXCU X Contractual Liah. PERSONAL& ADV INJURY 11000,0003C4222308/15/2017 08/15/2018 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE 2, 000, 000 PRODUCTS•COMPIOP AGG 2,000,000 PGLICY JEG LOG i t OTHER; AUTOMOBILE LIABILITY aMBIN IN UM S I, 000, 000 BODILY INJURY (Per person) s MANYAUTO 80DILY INJURY (Par 4Wd*M0 SBAUTO&DONLY X SCHEDULEDAUTOS74APB001893 X AUTOS ONLY X AUTOS ONLY 06/07/2017 06/07/2018 P80PE Y A A f f C X UMBRELLAUABiEXCESSLIABCLAIMS-MADE OCCUR NYL7EXC9137471C 08/15/2017 00/15/2018 EACHOCCURRENCE f 51000,000 AGGREGATE f 5/000/000 DED WORKER9COMPENSATIO H- STATUTE ER f E.L. EACH AGCIOENT fANDEMPLOYERS' LIABILITY YIN ANYPROPRIETORIPARTNERIEXECUTIVE E.L. DISEASE -EA EMPLOYEE fOFFICER/MEMBER EXCLUDED? Mandatory In NH) NIA E.L. DISEASE -POLICY LIMIT SItyes, dostdtae under DESCRIPTION OF OPERATIONS below I DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101, Additional Ramorks Schedule, may be attached It more space is rociulrod) City of Sanford Building Department 300 N Park Ave sanford, TL 32771 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE 1%zk n 4o51R_aR4F ArORF CORPORATION, All riDhts reserved. ACORD 25 (2016/03) The ACORD name and logo are registered marks of ACORD SA ID, 14959702 BATCH, 420556 WODn`YYY1 RaCERTIFICATEOFLIABILITYINSURANCE (Id THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the pollcy(les) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement A statement on this certificate does not confer ri hts to the certifi ate holder In lieu of such endorsements . PRODUCER Aon Risk SeNces, Inc of Flonda CONTACT NAME: Aon Risk Services, (nc of Florida TRURr- 1AIC, No Ext): 800.743.8130 AIC Not: $00-522-7514 100iBrickedBayDove, Sure mkt 100 Merni, FL 331314937 FMAIL ADDRE : ADP.COI.Cenler Ao .com INSURER( S) AFFORDING COVERAGE NAIC a INSURER A: Insurance Company of the State of PA 19429 INSURED Freedom Fire Protection of Central Florida nc INSURER a INSURER C 601CentralParkDave. Sanford, FL 32771 INSURER D : INSURER E : INSURER F : r: 0VEKACiES GI=KIIHL:AIIm NUMHln H' 1R44105 Kl^VniIUN NUMtlCK: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES, LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LIMITS SHOWN ARE AS REQUESTED. iNS LTR TYPE OF INSURANCE ADOL INSR SUBRI WVRPOLICY NUMBER POLICY EFF MWDDIY POLICY EXP MWDDIYYYY LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE f _ CLAIMSMADE OCCUR DAMAGE TO BE PREMISES (E4 o -- f MEO EXP AnY one person f PERSONAL A ADV INJURY f GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE f PRODUCTS• COMPIOP AGG f POLICY QPROJECT LOC t f OTHER AUTOMOBILELIABILITY Ea accident f BODILY INJURY Per arson f •- ANY AUTOOOILYINJURY( Pa(aectGem) f OWNED SCHEDULED AUTO$ ONLY AUTOS PROPERTY DAMAGE Per accident f HIRED NON- OWNEO AUTOS ONLY AUTO$ ONLY f UMBRELLA LIAO OCCUR EACH OCCURRENCE f AGGREGATE f EXCESS UAB CLAIMS -MADE DEC RETENTION It WORKERS COMPENSATION AND EMPLOYERS' LIABILITY YIN X PER OTH• STATUTE I JER E.L. EACH ACCIDENT f 2,000,000 A ANYPROPRIETORIPARTNERIEXEWTNE OFFICERIMEMBER EXCLUDED? Mandatory in NH) NIA WC 026160126 FL 7/1/2017 711/2018 E.L. DISEASE • EA EMPLOYEE f 2,000,000 E.L. DISEASE - POLICY LIMIT I f 2,000,000 rr ya, 4ewlea ua4. DESCRIPTION OF OPERATIONS below L DESCRIPTION OF OPERATIONS f LOCATIONS I VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached If more space Is required) Minimum Premium Policy Minimum Premium Policy cn Mit" Arc UnI ncc CANCELI ATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE City of Sanford Building Department THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 300 N Park Ave Sanford, FL 32771 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE W 1VOO- 4V 10 iA%,%Jr[v %,WFNr r.nrrv,.. n,. ..S, ,.+........ ...». ACORD 25 ( 2016/03) The ACORD name and logo are registered marks of ACORD CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION FIRE PLAN REVIEW SERVICE FEES PHONE: 407.688.5052 FAX: 407.688.5051 DATE: Z Z PERMIT NUMBER: If — BUSINESS/PROJECT NAME: ADDRESS: t s CONTACT NAME: PHONE: PLAN REVIEW INFORMATION CONSTRUCTION [ ]C/O [ ] FIRE ALARM UfiRESPRINKLER []HOOD [ ]PAINT BOOTH [ ]TANK DOES 20% REDUCTION IN FIRE IMPACT FEES APPLY: YES w TOTAL FEES: 5- FREEDOM REieIcrtlon, of CENTRAL FLORIDA, hue 601 Central Park Drive, Sanford, Ft. 32771 Phone: ( 407) 328-1663 * Fax: (407) 328-4768 Fire Sprinkler System Material Data PROJECT: Strada Units 12 & 13 Buildout 3400 St. Johns Pkwy Sanford, FL 32771 FROM: Freedom Fire Protection of Central Florida, Inc. 601 Central Park Drive Sanford, Florida 32771 WATE: May 14, 2014V QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT - PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements, Quick QUICK RESPONSE Response Sprinklers should be used advisedly and under the UPRIGHT CONVENTIONAL direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. QUICK RESPONSE TECHNICAL DATA PENDENT VERTICAL e See reverse side for Approvals and Specifications. SIDEWALL Temperature Ratings- 135°F (57*C), 1557 (68'C), 175°F (79-C), 200°F (93-C), 286°F (141-C) Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -670F (-55°C) QUICK RESPONSE Frame - bronze # Deflector - brass # Screw - brass HORIZONTAL LPCICE ORIZO Lodgement Wire - stainless steel e SIDEWALL HSIDEWALLNTAL Bulb seat - copper * Spring - nickel alloy e Seal - teflon Bulb - glass with alcohol based solution, 3mm size SPRINKLER TEMPERATURE RATINGICLASSIFICATION and COLOR CODING CLASSIFICATION IAVAILABLE SPRINKLER BULB COLOR N. F.P.A. MAXIMUM ITEMPERATURESIICEILINGTEMPERATUREORDINARY INTERMEDIATE 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 JULY 2012 A-20 ORANGE/ RED YELLOW/ GREEN BLUE 989- 846-4583 - FAX989-846-9231 BULLETIN GI-5615, REV. #9 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT, PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2,8 (39 metric) 1/2" NPT 2 1/4" (5.7cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7cm) Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7cm) White Polyester' 7.8 (111 metric) 1/2" NPT 2 114" (5.7cm) Black Polyester23 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2cm) METRIC CONVERSIONS ARE APPROXIMATE. HORIZONTAL SIDEWALL IS 2 9/16". FINISHES AVAILABLE ON SPECIAL ORDER, AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. d PPR(1VL1 t S SIN K 135'F 155'F 175'F 200'F 286`F FM LPC CE NYC-008NY STYLE MODEL FACTOR HAZARD 57'C 681C 79'C 931C 141'C MEAcULus101-92 E GL2815 2.8 LH X X X X X X X GL4215 4.2 LH X X X X X X X X UPRIGHT GL5615 5.6 LWOH X X X X X X X X X X G0115 7.8' LH/OH X X X X X X GL8118 8.1 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X X GL4201 4.2 LH X X X X X X X PENDENT L5601 5.6 LWOH X X X X X X X X X X X GL8101 7.8' LH/OH X X X X X X X GL8106 8.1 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X SIDEWALLt GL8133 8.1 LH X X X X X X GL2826 § 2.8 LH X X X X X X X X GL4226 § 4,2 LH X X X X X X XHORIZONTALGL5626 § 5.6 LH/OH X X X X X X X SIDEWALL GL5627a 5.6 LH/OH X X X X X X X GL8127 § 8.1 LH/OH X X X X X X CONVENTIONAL I GL5624 5.6 LHIUH X X X X X X X X OLD STYLE) I OLS125 1 8.1 1 LWOH X X X X X X 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 ANu ANY Q i Hart RELATED t.ry Vv . HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. aINSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN, SPACING, OH: ORDINARY HAZARD LH: LIGHT HAZARD 1/2" NPT ORDERING INFORMATION SPECIFY Quantity • Model Number • Style Orifice - Thread Sizes • Temperature Finishes desired Quantity - Wrenches - P/N 325390 (1/2"); PIN 312366 (L.O.) M611 s' 0gWj1. GLOBEO PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 1-800-248-0278 PRINTED U.S.A. FAX 989-846-9231 www.globesprinkler.com BULLETIN GL5615, REV. #9 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products, Our Schedule 10 and Schedule 40are FMApproved and ULListed (for U. and Conada), even though these products do not require separate approvals and listings, Bv|| Moose Tube made the decision <ohave them approved and listed for your peace ofmind, Our 8oh. 1Oand Suh.4V have been through the same rigorous testing as our other fine pipe products. Schedule 10 Pipe Schedule 4OPipe Bull Moose Tube' s Gch 10 and Soh. 40 pipes are made to A3TM AJ35 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot -dip galvanized to moat FM requirements for use in dry systems in a0000ianuo with the zinc coating specifications ofAGTM 8795 or GTM 853. All Schedule 10 and Ooheduio4O pipe has apressure rating of3OVPSI. PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation, Failure to take these Important steps may result In improper coupling assembly, causing leakage. Also, check the manufacturers instructions for the seecific fitting used. mmClarkson Road For additional information, Chesterfield, MO - R m r E wNY m mo m == --' tJ rm(: (636)537'2645 (636) oxr' osoomthe USA, v,from Canada<E> AC oumponv e-mail:' n(000}oaz nouAPPROVEDANinformationcontainedherein * accurate asknown mthe time * publication. wmMoose Tube reserves the right ° change product specifications without notice and Without Incurring obligation. SfF f=WV1L' DUCTILE IRON THREADED FITTINGS FIG. 3205 Straight Tee STRAIGHT Nominal Size Maximum Working Pressure• Dimension A Approx. WI. Ea<h Q J I S00 1.50 US 25 345. d 19 i 3Y 1Y4 S00 1,75 112 V 345 44-45 U._^S 1Vi 500 1.44 1.55 40 3450 44.71 0,10 2 Soo 2.25 2.45 50 3450 V i5 t_I? Working Pressure Ratings are for reference only and bored on Sch. 40 pipe, For the latest Ul./UfC, and FM essure ratings "er$V$ pipe schedule, please visit onvllinld.com or contact your local Anvil Representative. usno APPROVED IPnprrAP"N pptlk one 4irtulelbna, lobs d vmwAnWinO.wm or act. A.,O SltrF fkpnr.dvM. MATERIAL SPECIFICATIONS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B 1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength tlson that of stool pipe. Therefore, over tightening can cause damage to pipe threads which moy cause leakage. Ductile iron fittings should Ise tightened opproximateFy three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: [] Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/01•1.15 EPF-F-/ vl DUCTILE IRON THREADED FITTINGS ()A FIG. 3201 90' Elbow FIGURE • 900 Nominal Sizo Maximum Dimension A Approx. Wt. Each Working Pressure. mom 1 M Soo 1.50 , 0.62 0 3450 38 !0 018 1 V, Soo 115 0,90 3i 344 r 44 43 Q 4 1 500 1.44 1.20 40 3410 42116 054 2 500 2.25 1.85 5P 1 3450 1 57.6 0,84 Working Pressure Ratings are for reference only and based on Sch. 40 pipe, For the latest UIJULC, and FM pressure ratings versus pipe schedule, please visit onvilind.com or contact your fowl Anvil Representative. lDL . <FM> TED APPROVED rpp-1 M1Ws MC liewtiont. Vestl! N wnw.envl9M1W4ort Or A.0 Satyr R.pwrrnAWC MATERIAL SPECIFICATIONS Dimensions: ASME B 16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are Ul/ULC listed and FM Approved. NOTICE: Ductile iron fittings hove higher tensile strenggth than that of steel pipe. Therefore, over tightening eon cause damage to pipe threads which may cause leakage, Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECTE. r r APPROVAL s Project: © Approved Address: (]Approved as noted Contractor: [] Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI.1.15 n BROCHURE , x pt,-.q .,. L'*.`, 'd''<.-K •'•'"a4`,; 'r ;•;. $a."a.'.tmi'.S ax...+,G.':'.` ®„ir`.atiW;:,: ,a.., ,x..:.:....w, _._<.:s.ea..•.b,..'r:kw .._....;::>r<.:4 A. q". t i to sprin at COMMERCIAL FIRE SPRINKLER CONNECTIONS s t Product Submittal r: F.!~ p r. k4. e",Y•i#9/.id ti il...Y XW i': wr-n,., m APART OF A atkore 1111A MAI SprinkFLEX Stainless Steel Sprinkler Fittings connect the branch line to the sprinkler using oflexible stainless steel hose and reducer. The flexible stainless steel hose and fittings are intended for directconnection hmthe sprinkler and are particularly suited for use in suspended and hard ceiling applications. Each drop assembly comes with one stainless steel flexible hose, one branch line connection nipple, one sprinkler reducing nipple and bracket system. SYSTEM OPTIONS Pe- aooambled.ready Vminstall, vnbraidadand braided flexible stainless steel hose lengths: 28^(700mm).40^( 1000mm).48^(1200mn). 59r(1500mm).71"( 1800mn) 14^und V4" outlet fittings for connecting sprinkler Pre-assembled.ready minstall mounting bracket available in 24"and 48"long Mounting bracket allows the sprinkler wbelocate anywhere within the ceiling with reference marks in the center for ease p{installation without the need for measuring. Optional factory installed sprinkler head. TECHNICAL DATA w Maximum Working Pressure: 2VVpsi (18?5kPn Maximum Ambient Temperature: 3oV F( 11«V*C) Connection mBranch Line: 1-inch NPT Minimum Bend Radius ofFlexible Stainless Steel Hose: 3inches (7a.2mm)per ULListing 8inches (2O3. 2mm)per RNApproval The flexible stainless steel hose should not bvbent within 21/2inches (64mm)ofthe connection nut atboth ends. ULMaximum K' Facm,nfSprinkler tobeconnected tn Sprinkler Reducing Nipple: 0inch outlets: 8.0 W#inch outlets: 11.2 w FWMaximum K-Fanm, ofSprinkler *obeconnected *n Sprinkler Reducing Nipple: 1/2 inch outlets: 5.6 3qinch outlets: 8.0 Listings and Approvals: Unbraided models are ULListed Braided models are RNApproved and ULListed SFN28H 1 x 1/2 28" (700mm) 2 22aCa 1£ S i SFN28T 1 x 314 2$" (700mm) 2 28 ku gv8fi g SFN40H 1 x V2 40" (1000mm) 3 39wg P,,N4 SFN40T 1 x 3V4 40" (1000mm) 3 54 r R s SFN48H i x 1/2 48" (1200mm) 3 56 i e SFN48T 1 x 34 48" (1200mm) 3 63 ti { 1 x 1/2 59" (1500mm) 3 59 SFN59T 1 x 3/4 59" (1500mm) 3 74 SFN71H i x U2 71" (1800mm) 3 67 SFN71T 1 x 344 71" (1800mm) 3 74 c`S Vil qt x i•r n, f "9 ;4 #y £.. .Pd ` i 5'. Y Y k i' t's+Yj_ i f z }' SFB28H 1 x 1/2 28" (700mm) 2 22 1 46.4 j SFB28T 1 x 314 28" (700mm) 2 28 1 39.1 3 SFB40H 1 x V2 40" (1000mm) 3 39 i 53,9 t SFB40T 1 x 3/4 40" (1000mm) 3 54 1 45.3 w'=a:U' s{ ," SF648H 1 x L2 48" (1200mm) 3 56 2 73.4 SFB48T 1 x 314 48" (1200mm) 3 63 2 64.3 a 1 SFB59H 1 x L2 59" (1500mm) 3 59 3 89.9 m ` q st SFS59T 1 x 3/4 59" (1500mm) 3 74 3 86.5 WAR X s SF871H 1 x 1/2 71" (1800mm) 3 67 4 112.8 SFB71T 1 x34 71' (1800mm) 3 74 4 104.9 3s a 1 SF628H — E 1 x 1/2 28" (700mm) 2 1 48.4 2 SFB28T — E 1 x 3/4 28" (700mm) 2 1 41.1 SFB40H — E 1 x 1!2 40" (1000mm) 3 1 55.9 Threaded Mechanical Branch Tee qCSPF/F4NV1>L The MT-90 mechanical tee serves the same function as the MT-1 and MT-8, but uses a steel electro-plated u-bolt to save space for easier installation in tight places. The MT-90 is ideal For direct connections with sprinkler heads and drop nipples. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.onvilinti,com or contact your local Anvil Representative. C nul us < VdS LISTED APPROVED For LishogsfApproval Details and Landatlons, —1 Oro w6tmft at thnki.con, or —twl an MvP Sal. Rw—nlatrvo. I MATERIAL SPECIFICATIONS j HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 U-BOLT & NUTS: U-bolt is carbon steel SAE 1429 Gr, 2, zinc plated complete with hex Ranged lock nuts conforming to ASTM A-563 Gr. A or B of W 1995 Gr. 2. THREADS: BSPT pipe thread COATINGS: Zinc Electroplated Other available options: Example: PAL3000 or RAL9000 Series GASKETS: Materials Properties as designated in accordance with ASTM D-2000. E] Grade "E" EPDM (Green color code) 40°F to 230°F (Service Temperature Range)(-40°C to I I O'C) Recommended for water service, diluted acids, alkalies solutions, oil -free air and many chemical services not involving hydrocarbons, oils or gases. NOT FOR USE WITH HYDROCARBONS, FP-412 5PF/RNYIL Threaded Mechanical Branch Tee 1 Nominal Size pipe 0.0. THREADED Hole Dimensions Max, Working Pressure& MECHANICAL BRANCH Dimensions Approx. Wt, Ea. Min, Diameter Max. Diameter A B C T Take-out lnlmm 4s:/7( 1'1/4 x V? 1.660 x 0,840 1316 30 V/16 f3 300 110.,T 21/s c4 31l2 rg 21A 1 s/a 0.8 1''A x 3/4 j ?A 14 1.660 x 1.050 i.4 ,Y 26 13/16 15/i6 300 21la V2 21/4 13/a U id 1'A x 1 tx`1/2 1.660 x 1.315 1'/46 15/16 300 21/4 31/2 2'i4 11/8 1.1 11/2 1.900 x 0.840 1 VI 15/16 300 21h 31/2 21/4 11/4 0.8 1'/2 x 1/4 1.900 x 1,050 1'/16 15/16 300 2i/4 31/2 21/4 11/4 0.9 11112xx 1 1.900 x 1,315 13/is V/16 300 2% 311/2 21/4 11/4 1.1 2 x 11/2 2.375 x 0.840 13/16 0/4 300 21/2 33/4 2'/4 2 0.9 2 x 3/4 2.375 x 1.050 13/16 1 /16 300 21/1 31/4 2!/4 2 0.9 2 x lV 2.375 x 1.315 1'/,6 1V 300 2S/s 3f4 2A 2 1.1 3 O.D. x'112 2,996 x 0.840 1Y16 1S-`s 300 2'/s 4'1/4 2'/4 21is 0.9 3 O.D. x'/4 2.996 x 1,050 13/s 14/16 300 21/a 41/4 2'1/4 2% 0.9 3 Off x 1 2,996 x L315 13/,,6 I s/16 300 3 4Y4 21/4 21/4 1.1 A - Working Pressure Ratings ore for reference only and based an $ch- 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit onvilinil.con, or contact your local Fusvil Representative. Note: Tighten nuts alternately to a recommended torque of 18-22 ft -lbs. (25 30 Nm) on pipe wall less than schedule 10 (Din 2440) or 23 27 It Abs. (31 37 Nm) on pipe walls schedule 10 (DIN 2440) and above. A WARNING For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok14 Xtreme"' lubricant is required. FP-4.12 Material: Steel Tensile Strength: 58,000 psi Yield Strength: 36,000 psi aERICO* Load based on Max. 650 degrees F, WARNING ERICO products shall be installed and used only as indicated in ERICO's product instruction sheets and training materials. Instruction sheets are available at www,erico.com and from your ERICO customer service representative. improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. Copyright O 2015 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. aERICO® Conforms with Federal Specification WW-H-171 (Type 23), Manufacturers Standardization Society ANSI'iMSS-SP-58 (Type 19 and 23) IA fro r" fir, rt Material: Steel C @us FM Apo OVM Setscrew must be tightened and torqued onto the sloped side of the I-beam. Recognizing that torque wrenches are generally not used or available on many Job sites, the setscrew should he tightened so it contacts the I-beam and then an additional 1/4 to 112 turn added. ANSI is a registered trademark of American National Standards Institute. FM ;s a registered certification mark of FM Approvals LLC, LTD. UL, UR, cUL, CUR, cULus and cURus are registered certification marks of UL U.C. WARNING ERICO products shall be installed and used only as indicated in ERICO's product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. Copyright © 2015 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation_ ERIC13" The 115 Standard Duty Loop Hanger, part of the CADDY* line of fasteners and supports from ERICA, is ideal for suspending stationary, non -insulated pipe lines, including CPVC pipes, in fire sprinkler systems. A knurled insert nut helps simplify vertical adjustments and flared edges on the base (1/2" to 4" sizes) help protect pipes from coming into contact with any sharp edges of the hanger, Flared edges help prevent any sharp surfaces from coming into contact with the pipe (112 " to 4' sizes) Retained insert nut helps ensure the loop hanger and insert nut stay together Recommended for the suspension of stationary non -insulated pipe lines Manufactured to use the minimum rod size permitted by NFPA* for fire sprinkler piping Conforms with Federal Specification VVW-H-1 71 (Type 10), Manufacturers Standardization Society (MSS) SP-58 (Type 10) T A Material: Steel Finish: Pregalvanized C & us FM iERIC13" FREEDOM P, Fwo ire ection, of CENTRAL FLORIDA, Inc 601 Central Park I)rive, Sanford, FIL 32771 Phone: (407) 328-1663 #Fax: (407) 328-4768 Fire Sprinkler System Material Data PROJECT: Strada Units 12 & 13 Buildout 3400 St. Johns Pkwy Sanford, FL 32771 FROM: Freedom Fire Protection of Central Florida, Inc. 601 Central Park Drive Sanford, Florida 32771 DATE: May 14, 2018 QUICK AUTOMATIC SPRINKLERS m_ SERIES r* rUPRIGHTPENDENT VERTICAL "mD-m m n y (OLD STYLE) v,°",, v DESCRIPTION AND OPERATION The Globe Quick Response GLSeries Sprinklers are olow profile yet durable design vWloh utilizes a 3mm frangible glass ampule aothe thermooeneiUvoelement. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the {]u|nk Response Sprinkler provides an aesthetically pleasing oppearance, it can be installed wherever standard spray sprinklers are specified when allowed bythe applicable standards. hoffers the additional feature ofgreatly increased safety tulife and is mvmi|eWe in various sty|es, urifices, temperature nmUngm and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction, The heart ofGlobe's GLSeries sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely rnoawunad amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass toshatter. This results inwater discharge which (udistributed inanapproved pattern depending upon the deflector style used. TECHNICAL w DATA QUICK RESPONSE UPRIGHT CONVENTIONAL 1JMZr QUICK RESPONSEPENDENT VERTICAL SI DE A See reverse side for andSoec cat0m ------ Temperature Ratings - 135°F(570(J). 155*F( 680C). 175"F(790C).200"F(93°C).280" F(141"C) Water Working Pressure Rating -175psi (12Bars) Factory tested hydrostatically bo5U0psi /34Bars) Maximum low temperature glass bulb rating ia-O7°F(-55" C) QUICK RESPONSE Frann'bronz ^ OaOec nr'breaa onevv'bnaun HORIZONTAL LPC/CE D VVALL HORIZONTAL Lodgement Wire - stainless steel ° 8|DEVVALL Bulb seat -copper w Spring - nickel alloy ^ Seal 'teOon Bulb ' glass with alcohol based solution, 3mnnsize SPRINKLER TEMPERATURE RATINGICLASSIFICATION and COLOR CODING 4o77A1RPxRKDRIVE, STAND0H.M|CH| G*N4VO58 880,0484583 ~ FAX989-846- 9231 QUICK RESPONSE AUTOIv AT1C SPRINKLERS GL. SERIES UPRIGHT . PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFIC TIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2,8 (39 metric) 1/2" NPT 2 1/4" (5.7cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7cm) Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7cm) White Polyester 3 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7cm) Black Polyester x' 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2cm) METRIC CONVERSIONS ARE APPROXIMATE, HORIZONTAL SIDEWALL IS 2 9116". FINISHES AVAILABLE ON SPECIAL ORDER. AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS SIN K 135'F 155'F t75'F 200'F 286'F cULus FM LPC CE NYC • DOB STYLE MODEL FACTOR HAZARD 57'C 68'C 79T 93'C 141'C MEA 101-92-E GL2815 2.8 LH X X X X X X X X GL4215 4.2 LH X X X X X X X UPRIGHT GL5615 5.6 LWOH X X X X X X X X X GL8115 7.8' LH/OH X X X X X X X GL8118 8A LHIOH X X X I X X X X X X GL2801 2.8 LH X X X X X X X X 04201 4,2 LH X X X X X X X x PENDENT GL5601 5.6 LWQH X X X X X X X X GL8101 7.8" LWOH X X X X X X X X GL8106 8.1 LWOH X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X SIDEWALL' GL6133 8.1 LH X X X X X X GL2826 § 2.8 LH X X X X X X X X GL4226 § 4.2 LH X X X X X X XHORIZONTALGL5626 § 5 6 LWOH X X X X X X X SIDEWALL GL5627o 5.6 LWOH X X X X X X X 3 .127 § 8.1 LWOH X X X X X X CONVENTIONAL GL5624 5.6 LWQH X X X X X OLD STYLE) OL8125 8.1 LWQH X X X X X X 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTTS. HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4' TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. NINSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS, PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN, SPACING, OR ORDINARY HAZARD LH: LIGHT HAZARD 112" NPT ORDERING INFORMATION SPECIFY Quantity ' Model Number ' Style Orifice • Thread Sizes • Temperature Finishes desired Quantity - Wrenches - P/N 325390 (1/2"); PIN 312366 (L.O.) FI IIt1 x CIN JUNE 2012 GLOBE`S PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our Warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 1-800-248-0278 PRINTED U.S.A, FAX 989-846-9231 www,globesprinkler.com BULLETIN GL5615, REV. #9 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Schedule 10 Pipe Schedule 40 Pipe Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot -dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. All Schedule 10 and Schedule 40 pipe has a pressure rating of 300 PSI, PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these Important steps may result in Improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, g ( 03 Chesterfield, MO 63017 contact your salesperson i MUMOOSE. E GoMpANY (801) 325.4467 today at (800) 325-4467 or usTEMULL FAX: ( 636) 537-2645 (636) 537.2600 in the USA, www, bullmoo ttibe.com or from Canada FM ACBMcornpanY e-mail: s lea ullmo et e. n1 call ( 800) 882-4666 uPaovcu AN intorrnation contained herein is accurate as known at the area of publication. Qug Moose Tube reserves the fight to change product specifications without notice and without incurring obligation. 12/ 09 ZF- fL/ VIL > DUCTILE IRON THREADED FITTINGS ,/AJWA FIG. 3205 Straight Tee STRAIGHT Nominal Size Maximum Working Pressure,& Dimension A Approx. WI, Each 1 500 1,50 0.85 Z5 3451,11 3d ' 7 1` 1Y 19r Soo 1.75 1.22 32 1450 4Q_45 4S4 1' 500 1.44 1.55 40 3450 021 010 2 Soo 2,25 2.45 50 3450 1 51 151 f l Working Pressure Ratings ore far reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedvle, please visit onvilind.com or contact your bcd Anvil Representative. Usno APPROVED WWApmnN pna1r.4lirwaaYau, Our."w N --sow am Cr 1.0 M Mvpr .wl Rs"'M va. Dimensions: ASME B 16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved, NOTICE: Ductile iron fittings have higgher tensile strength than that of steel Pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron finings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECTINFORMATION APPROVAL STAMP Project: [ Approved Address: []Approved as noted Contractor: [ Not approved Engineer: Remarks: Submittal hate: Notes 1: Notes 2: SPF/01-1, t 5 DUCTILE IRON THREADED FITTINGS ! U4 ELBOW Nominal Size Maximum Working PressureA, Dimension A Approx. Wt. Each 1 Soo 1.50 0.62 lC MO 36A 73 1Y4 Soo 11S 0.40 3Z 34 5 0 44.4j 3' 1 Soo 1.44 1,20 40 PA 4Y M 0, 54 2 500 2,25 1.85 SO 1 34S0 57, i_i Qua Working Pressure Ratings are for reference only and based on 56. 40 pipe. For the latest UL(ULC, and FM pfessure ratings versus pipe schedule, please visit onvilind.com or contact your local Anvil Representative. 1 us FM APPROVED rpPraral OetW .4 UtWlionb MMW nwwwwnvwo—a nn MvIP $YNF R.P—M10ee. Dimensions: ASME B 16.3 Material: ASTM A536 Grade 65.45.12 Finish: Black Threads: NPT per ASME Bi.2Q.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC listed and FM Approved, NOTICE: Ductile iron fittings have higher tensile strenggth than that of steel pipe. Therefore, over tightening can cause damage to pipe tf reads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. Ir rtPROJECTINFORMATION Project: Y k( STAMPAPPROVAL Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPFIDt-1.15 CHURE IrA r it l v! COMMERCIAL FIRE .'SPRINKLER CONNECTIONS IlaProdu"ct Submi ia Af APART OF tr atkore SphnkPLEXStainless Steel Sprinkler Fittings connect the branch line Vothe sprinkler using oflexible stainless steel hose and reducer. The flexible stainless steel hose and fittings are intended for directconnection to the sprinkler and are particularly suited for use in suspended and hard ceiling applications. Each drop assembly comes with one stainless steel flexible hose, one branch fine connection nipple, one sprinkler reducing nipple and bracket system. SYSTEM OPTIONS Pre-aouvmbled. ready minstall, v"braidedand braided flexible stainless steel hose lengths: 28`(700mm).40^(/000mn). 48"(1200mm). 69r(1500mm).71~(1800mn) 14"and 314" outlet fittings for connecting sprinkler Pm-axoomblod.ready minstall mounting bracket available in24"and 40"long Mounting bracket allows the sprinkler tobolocate anywhere within the ceiling with reference marks io the center for ease o( installation without the need for measuring. Optional factory installed sprinkler head, TECHNICAL DATA Maximum Working Pressure; 2VOpsi (1375kP^ Maximum Ambient Temperature: 300F(I 49I) Connection mBranch Line: 1-inch NPT Minimum Bend Radius ofFlexible Stainless Steel Hose: Oinches (76.2mn) per ULListing 8inches (2V8.3m,") per nNApproval The flexible stainless steel hose should not bebent within 8V2inches ( n4mm)o[the connection nut mt both ends. ULk4oximum K' Facto,pfSprinkler !obnconnected to Sprinkler Reducing Nipple: 1/2inch outlets: 8.O W4inch outlets: 11.2 RNMaximum K' Faoto,o(Sprinkler uoheconnected m Sprinkler Reducing Nipple: 1/ 2 inch outlets: 5.6 Y4 inch outlets: 8.0 Listings and Approvals: Unbraidedmodels are ULListed Braided models are Fk4Approved and ULListed SFN40T 1 x V4 40" (1000mm) 3 54 } q SFN48H i x 1/2 48" (1200mm) 3 56 SFN48T 1 x 3/4 48"" (1200mm) 3 63 . SFN59H 1 x 1/2 59" (1500mm) 3 59 y SFN59T 1 x 3/4 59" (1500mm) 3 74 SFN71H 1 x V2 71" (1800mm) 3 67 1 } SFN71T 1 x 34 71" (1800mm) 3 74 h 7 1` L a ss } zi c'i , .t,' d } ly i.k\ ae .•.,% k of i i Yx 28" (700mm} 2 22 1 46.45FB28H1xV2 SF i x 34 28" (700mm) 2 28 1 39.1 a SFB40H i x U1 40" (1000mm) 3 39 1 53.9 SFB40T 1 x 34 40" (1000mm) 3 54 1 45.3 SF848H 1 x tit 48" (1200mm) 3 56 2 73.4 x SF848T 1 x 3Y4 48" (1200mm) 3 63 2 64.3 z SFB59H 1 x V2 59" (1500mm) 3 59 3 89.9 a SF859T 1 x 3'4 59" (1500mm) 3 74 3 86.5 N SFB71H 1 x 1/2 71" (1800mm) 3 67 4 112.6lpiz i t,M 1M SF671T 1 x 3/4 71 ' (1800mm) 3 74 4 104 9 1 t i A N`aF"3 Wes" SFB28H — E 1 x 1/2 28" (700mm} 2 1 48.4 SF1328T — E 1 x 34 28" (700mm 2 1 41.1 SFB40H — E S s0 1 x V"2 40" (1000mm) 3 1 55,9}, SFB40T — E SFB48H — E 1 x 3+4 1 x 1/2 40° (1000mm) 48" (1200mm) 3 3 1 47.3 2 75.4 M SFB48T—E 1 x34 48"(1200mm) 3 2 66.3 xt 11V SF859H — E 1 x V2 59" (1500mm) 3 3 91.9 ai: SFB59T— E i x 34 59" (1500mm) 3 3 88.6 N-N SFB71H — E 1 x 0 71" (1800mm) 3 4 114.8 A SFB71T—E 1 x V4 71" (1800mm) 3 4 106.9 Threaded Mechanical Branch Tee The MT-90 mechanical tee serves the some function as the MT-1 and MT-8, but uses a steel electro-plated u-bolt to save space for easier installation in tight places. The MT-90 is ideal for direct connections with sprinkler heads and drop nipples. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www,anvilinti.com or contact your local Anvil Representative. I MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 U-BOLT & NUTS: U-bolt is carbon steel SAE J429 Gr 2, zinc plated complete with hex flanged lock nuts conforming to ASTM A-563 Gr. A or B of SAE J995 Gr. 2. THREADS: BSPT pipe thread USTEO APPROVED VDdS Fw U.Wgs/Apj-al DW,K and L-10. IM our -Wtat inti— . c~ - A-4- U. RW..10v0 COATINGS. El Zinc Electroplated El Other available options: Example: RAL3000 or RAL9000 Series GASKETS: Materials Properties as designated in accordance with ASTM D-2000 0 Grade "E" EPDM (Green color code) 40° F to 230'F (Service Temperature Range)(-40°C to 11 0,C) Recommended for water service, diluted acids, alkalies solutions, oil - free air and many chemical services not involving hydrocarbons, oils or gases, NOT FOR USE WITH HYDROCARBONS. FP- 412 qCSP F/ NVIL Threaded Mechanical Branch Tee IB T C ANVIL Nominal Nominal Pipe O.D.Sae MT-90 BSP THREADED Hole Dimensions MECHANICAL BRANCH TEE Max, Dimensions Approx. Wt, (a. Min, Diameter Max, Diameter Working Pressure,& A B T Take-out in 1 0,/MM Lalmo 1OLMM la/Mm nA lbK/w 11/4 x '/Z 3 9 x 1 ? 1 .660 x 0.840 4 " '! , I i I 1 R16 30 Y16 J3 300 T 2'A 4 T/7 j 9 TA I ',', 13078, Aj. 1A x Y, X 1,660 x 1050 414 16 R14 30 11/16 3,3 300 21/s 4 31/2 21/4 Q 11/8 4f 0.8 4 1 'A X 1 1.660 x 1.315 Y16 IVIS 300 V 2 i4 3 16 2/4 1 to 1.1 I V? x 6 1.900 x 0.840 1 3/14 1 300 21/4 3 111 21/4 11/4 0.8 l,900 —X-1 050 11/16 154e 300 2/4 3'/2 TA 1 ?V4 0.9 17/, x —1 1,900 x 1315 1"/"6 1 YI 6 300 2% 31/2 2 x'/7 2.375 x 0,840 1'& 300 21/2 31/4 21/4 2 0.9 2 x'/4 2.375 x 1,050 13/16 15/16 300 2/7 3,1/4 TA 2 0.9 j 2 x 1 2,375 x 1,315 13"1 1 vt 300 214 3,1/4 211/4 2 1.1 TO-D—X —1/" 2,996 x 0,840 11/, 6- 14h6 300 2A 4/4 T/i 2 '4 0.9 3 O.O. x 1/4 2.996 x 1.050 1 /14 11/16 300 2% 4 4 TA 2% 0.9 3 0 - .0. x 1 2.996 x 1.315 11/16 0/16 300 3 41/4 2/4 2'/4 1.1 A - Working Pressure Ratings are for reference only and based on Sch 40 pipe For the latest UL/ULC, FM, VdS and tPCB pressure ratings versus pipe schedule, please visit onvilintl com or contact your local Anvil Representative Note: Tighten nuts alternately to a recommended torclue of 1822 It -165 (25 30 Ntn) on pipe wall less than schedule 10 (Din 2440) of 23 27 It -lbs (31-37 Nm) on pipe walls schedule 10 (DIN 2440) and above. A WARNING For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok* XtreMeT' Lubricant is required. FP- 4,12 Material: Steel Tensile Strength: 58,000 psi Yield Strength: 36,000 psi aERICG* Load based on Max. 650 degrees F. WARNING ERICO products shall be installed and used only as indicated in ERICO's product instruction sheets and training materials. Instruction sheets are available at wwv.erico.com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. Copyright 0 2015 ERICO International Corporation. All rights reserved. CARRY, CAPWEtO, CRITEC, ERICO, ERIEL.EX ERITECN, and tENTON are registered trademarks of ERICO lotemanonal Corporation. iERICA® Conforms with Federal Specification WW-H-171 (Type 23), Manufacturers Standardization Society ANSI*/MSS-SP-58 (Type 19 and 23) Fri I q5 fry t2 Material: Steel Setscrew must be tightened and torqued onto the sloped side of the I•beam_ CL uS F M AM DYCD Recognizing that torque wrenches are generally not used or available on many job sites, the setscrew should be tightened so it contacts the I-beam and then an additional 1/4 to 112 turn added. ANSI is registered trademark of American National Standards Institute. FM is a registered certification mark of FM Approvals LLC, LTD. UL, OR, cUL, cut, cULus and cURus are registered certification marks of UL LLC, WARNING ERICO products shall be installed and used only as indicated in ERICO's product instruction sheets and training materials. Instruction sheets are available at www.enco.com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. Copyright O 1015 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEK ERITECH, and EENTON are registered trademarks of ERICO International Corporation. aERIC130 The 115 Standard Duty Loop Hanger, part of the CADDY* line of fasteners and supports from ERICO, is ideal for suspending stationary, non -insulated pipe lines, including CPVC pipes, in fire sprinkler systems. A knurled insert nut helps simplify vertical adjustments and flared edges on the base (1/2" to 4" sizes) help protect pipes from coming into contact with any sharp edges of the hanger, Flared edges help prevent any sharp surfaces from coming into contact with the pipe (112 " to 4" sizes) Retained insert nut helps ensure the loop hanger and insert nut stay together Recommended for the suspension of stationary non -insulated pipe lines Manufactured to use the minimum rod size permitted by NFPA* for fire sprinkler piping Conforms with Federal Specification VVVV-H-1 71 (Type 10), Manufacturers Standardization Society (MSS) SP-58 (Type 10) on Material: Steel FM Finish: Pregalvanized UPy ERICU UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering - Environmental Sciences Geophysical Services - Materials Testing - Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407,423.3106 Inspection Report Project Name: Backyard Date: Work Girder o.113359 06/1 4201 Any any Address: 3440 St Johns Pkwy Suite 1008— Bldg B, Sanford, Seminole Permit No: 18-1 County, FL 32771 Client: Strada Electric Lot No.: ProjectNo.: 01 15.1800209MOO-011 15-002 Contact: Nicole Fusco at 877-906-1113 Scope of Inspection: Strada Electric Build out - CODE 219 Electrical Ceiling Rough -In Inspection Inspection Type: See Scope Disposition of Inspection: Pass Comments: TA§A-pAt& I411KAO-W Y"r Nang 06/1212018 rough elect insp and pre power. John Jackson I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: John Jackson, BIN 906 UNIVERSAL. ENGINEERING SCIENCES Consultants In: Geotechnical Engineering - Environmental Sciences Geophysical Services - Materials Testing - Threshold Inspection Building Code Administration, Compliance Inspection& Plan Review 3532 Maggie Blvd, Orlando, Ft_ 32811 - P: 407.423.0504 - F: 407.423.3106 Inspection Report M Project Name: AutoTex Address: 3440 St Johns Pkwy Suite 1074 — Bldg 6, Sanford, Seminole County, FL 32771 Client: Strada Electric Work Order No. 113358 Date: 06/12/2018 Any any Permit No: 18-1985 Lot No.: ProjectNo.: 01 15. 1800209.0000-0115-001 Contact: Nicole Fusco at 877-906-1113 Scope of Inspection: Strada Electric Build out - CODE 219 Electrical Ceiling Rough -In Inspection Inspection Type: See Scope Disposition of Inspection: Pass Comments: inkP" IMAK Note UWAOM 06/12/2018 rough elect insp and pre power. John Jackson 06/12/2018 rough elect insp and pre power, John Jackson I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code, Inspector: John Jackson, BN 906 JBUNIVERSALENGINEERINGSCIENCES Consultants In: Geotechnical Engineering - Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Inspection Report Project Name: Backyard Address: 3440 St Johns Pkwy — Bldg B, Sanford, Seminole County, FL 32771 Unit #1062 Client: Strada Electric ProjectNo.: 01151800209.0000-0115-002 Work Order No. 111666 Date: 05/23/2018 Any am Permit No: 18-1986 Lot No.: Contact: Joe Strada at 407-421-2522 Scope of Inspection: Strada Electric Build Out - CODE 220 Rough Electrical Inspection Inspection Type: See Scope Disposition of Inspection: Pass I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN 1900 UNIVERSAL 0 N N 0 Consultants In: moutechuua|Engineering ~ Environmental Sciences Geophysical Services ^ Materials Testing ^ Threshold Inspection Building Code Administration, Compliance |",ne,unnmPlan Review 3532Maggie Blvd, Orlando, FL 32811 -P:407.423.0504 -F:4O7.423.81O6 Inspection Reppirt Project Name: Backyard Address: 3440 St Johns Pkvvy— Bldg B, Smnford, Seminole Counhy, FL 32771 Und# 1O62 Client: StnadaBeothc PnojoctNo.: 0115. 1800209.0000'0115-002 Work Order No. 111667 Date: 05/ 23/2018 Any am Permit No: 18-1986 Lot Nn. Contact: Joe Strada at40742i-2522 Scope of Inspection: Strada Electric Build Out - CODE 322 RougV/UG Plumbing inspection Inspection Type: See Scope Disposition of Inspection: Pass hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections oKthe Florida Building Code. Inspector: Randy Lamb, BN19O0 q 4 47- zjl UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering * Environmental Sciences Geophysical Services - Materials Testing - Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Work Order No. 111666 Inspection Report Project Name: Backyard Date: 05/23/2018 Any am Address: 3440 St Johns Pkwy — Bldg B, Sanford, Seminole County, F Permit No: 18-1986 32771 Unit #1062 Client: Strada Electric Lot No.: ProjectNo.: 0115,1800209.0000-0115-002 Contact: Joe Strada at 407-421-2522 Scope of Inspection: Strada Electric Build Out - CODE 220 Roup"In Electrical Inspection Inspection Type: See Scope I Disposition of Inspection: Pass I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN 1900 qP4 9 ( 7 y, UNIVERSAL. ENGINEERING SCIENCES Consultants In: Geotechnical Engineering - Environmental Sciences Geophysical Services - Materials Testing - Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 MM7#M=;M=# Project Name: AutoTex Address: 3440 St Johns Pkwy — Bldg B, Sanford, Seminole County, FL 32771 Client: Strada Electric ProjectNo.: 01 151800209.0000-01 15-001 Scope of Inspection: Strada Electric Build Out - CODE 103 Monolithic Inspection Type: See Scope ition of Inspection: Pass Work Order No. 111721 Date: 05/24/2018 Any am Permit No: 18-1985 Lot No.: Contact: Joe Strada at 407-421-2522 lab Inspection I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN 1900 UNIVERSAL. ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection& Plan Review 3532 Maggie Blvd, Orlando, FL 32811 -P:407.423.0504 - F: 407.423.3106 Work Order No. 111720 Inspection Report Project Name: AutoTex Date: 05/24/2018 Any am Address: 3440 St Johns Pkwy — Bldg B, Sanford, Seminole County, FL Permit No: 18-1985 32771 Client: Strada Electric ProjectNo.: 01 15.1800209.0000-01 15-001 Lot No.: Contact: Joe Strada at 407-421-2522 Scope of Inspection: Strada Electric Build Out - CODE 317 2nd tough Plumbing Inspection Inspection Type: See Scope Disposition of Inspection: Pass I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN 1900 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering * Environmental Sciences Geophysical Services - Materials Testing - Threshold Inspection Building Code Administration, Compliance Inspection& Plan Review Inspection Report Work Order No. 111664 Project Name: AutoTex Date: 05/23/2018 Any am Address: 3440 St Johns Pkwy — Bldg B, Sanford, Seminole Coun gi, FL Permit No: 18-1985 32771 Unit# 1008 Z Client: Strada Electric Lot No.: ProjectNo.: 0115.1800209.0000- 0115-001 Contact: Joe Strada at 407-421-2522 Scope of Inspection, Strada Electric Build Ot - CODE 30 Rough/UG Plumbing Inspection Inspection Type: See Scope of Inspection: Pass I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN 1900 UNIVERSAL 0 0 N Consultants In: oe^tech"xo|Engineering ^ Environmental Sciences Geophysical Services ^ Materials Testing ^ Threshold Inspection19BuildingCodeAdministration, Compliance Inspection mPlan Review 3532Maggie Blvd, Orlando, FIL 82811 'P:4O7.428.U5D4 'F:4O7.423.81O6 Inspection Report Project Name: AuhmTex Address: 3440StJohns Pkvvy—Bldg B.Sanford, Seminole County, FL 32771 Unit#1008 Client: Stnada Electric Work Order No. 111663 Date: 05/23/ 2018 Any am Permit No: 18' 1985 Lot No.: Contact: Joe Stradoat40421- 2522 Scope VfInspection: ShadaElectric Build Out - CODE 22O Rough lectrical Inspection Inspection Type: See Scope Disposition of Inspection: Pass hemby affirm that to the best of my knowledge and belief, th&Aove|isted inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN1800 qP4 96-2 j UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering - Environmental Sciences Geophysical Services * Materials Testing - Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3632 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 InsDection Resort Project Name: New Life Vitamins - Suite 1092 Address: 3440 St Johns Pkwy Suite 1008— Bldg B, #1092, Sanford, Seminole County, FL 32771 Client: Strada Electric ProjectNo.: 0115.1800209.0000-0115-003 Work Order No. 119756 Date: 08/21/2018 Any am Permit No: 18-2292 Lot No.: Contact: Mark Moorefield at 407-221-7289 Scope of Inspection: Strada Electric Build -Out - CODE 316 Rough Plumbing Inspection Inspection Type: See Scope Disposition of Inspection: Cancel Comments: T49KDOW TA%K_N9AQ U"LNNW 08/21/2018 Previously inspected and passed Randy Lamb I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN 1900 UNIVERSAL. ENGINEERING SCIENCES Consultants In: Geotechnical Engineering - Environmental Sciences Geophysical Services * Materials Testing - Threshold Inspection Building Code Administration, Compliance Inspection& Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407,423.0604 - F: 407.423.3106 Inspection Report Project Name: New Life Vitamins - Suite 1092 Date: Address: 3440 St Johns Pkwy Suite 1008— Bldg B, #1092, Sanford, Permit No: Seminole County, FL 32771 Client: Strada Electric Lot No.: ProjectNo.: 01151800209.0000-0115-003 Contact: Scope of Inspection: Strada Electric Build -Out - CODE 409 Mechanical Rough Inspectior Inspection Type: See Scope Disposition of Inspection: Fail Work Order No. 119757 08/21/2018 Any am 18-2292 Mark Moorefield at 407-221-7289 Comments: TA§K,Pgq Task Note U§kr-NMQ 08/21/2018 Not ready for inspection Randy Lamb I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN 1900 14 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering - Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3632 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Work Order No. 119758 Inspection Report Project Name: New Life Vitamins - Suite 1092 Date: 08/21/2018 Any am Address: 3440 St Johns Pkwy Suite 1008— Bldg B, #1092, Sanford, Permit No: 18-2292 Seminole County, FL 32771 Client: Strada Electric Lot No.: ProjectNo,: 0115.1800209.0000-0115-003 Contact: Mark Moorefield at 407-221-7289 Scope of Inspection: Strada Electric Build -Out - CODE 121 Building Above Ceiling Inspection Inspection Type: See Scope Disposition of Inspection: Pass I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code, Inspector: Randy Lamb, BN 1900 UNIVERSAL. ENGINEERING .'SCIENCES Consultants In: Geotechnical Engineering - Environmental Sciences Geophysical Services - Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection& Plan Review 3632 Maggie Blvd, Orlando, FL 32811 -P:407,423.0504 - F: 407.423.3106 Inspection Report Project Name: New Life Vitamins - Suite 1092 Work Order No. 119759 Date: 08/21/2018 Any am Address: 3440 St Johns Pkwy Suite 1008— Bldg B, #1092, Sanford, Permit No: 18-2292 Seminole County, FL 32771 Client: Strada Electric Lot No.: ProjectNo.: 01151800209.0000-0115-003 Contact: Mark Moorefield at 407-221-7289 Scope of Inspection: Strada Electric Build -Out - CODE 313 Final Plumbing Inspection Inspection Type: See Scope Disposition of Inspection: Pass I hereby affirm that to the best of my knowledge and belief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BIN 1900 UNIVERSAL N 0 N± Consultants /nio~otecxoicmconmmt-rinn^Environmental Sciences Geophysical Services " Materials Testing ^ Threshold Inspection Building Code Administration, Compliance Inspection mPlan Review 3533Maggie Blvd, Orlando, FL 32811 'P:4o7.4%3.o504 -F:4u7.428.310G Work Order No. 119760 Inspection Report Project Name: New Life Vitamins - Suites 1092 & 1080 Date: 08/21/2018 Any am Address: 3440StJohns Pkwv—Bk]oB.#1O92&#108O.Sanford. Permit No: 18'2282 GeminoCou - - Client: StradaEleobic Lot No.: ProjecdNo.: 01151800209.0000- 0115-003 Contact: Scope ofInspection: EKradaElectric Build -Out - CODE 218PrepuwerInspection Inspection Type: See Scope Disposition ofInspection: Pass Mark Moorefield at4U7-2 1- 7288 Comments: I"* QM ImXJNqte g" rRom hereby affirm that to the best of my knowledge andbelief, the above listed inspection was performed as indicated and the work was reviewed for compliance with the approved plans, and all pertinent sections of the Florida Building Code. Inspector: Randy Lamb, BN1SOU