Loading...
HomeMy WebLinkAbout2702 French Ave; 99-2523; FOUNDATION ONLYw FVZ)-2 C/-- llyLlk-e- ZONE CONTR, ADDRESS PHONE # LOCATIOP OWNER ADDRESS PHONE # PLUMBING CONTRACTOR ADDRESS PHONE # ELECTRICAL CONTRACTOR ADDRESS PHONE # MECHANICAL CONTRACTOR ADDRESS PHONE # MISCELLANEOUS CONTRACTOR ADDRESS SEPTIC TANK PERMIT NO. SOIL TEST REQUIREMENTS (__) FINISHED FLOOR ELEVATION REQUIREMENTS (_) ARCHITECTURAL APPROVAL DATE: SUBDIVISION PERMIT # JOB COST $ LOT NO BLOCK: SECTION: SQUARE FEET: FEE $ n MODEL: / j, STATE NO.C6C6 66` OCCUPANCY CLASS: V' FEE $ FEE $ FEE $ INSPECTIONS TYPE DATE OK REJECT BY FEE $ ENERGY SECT. CERTIFICATE OF OCCUPANCY ISSUED # DATE: FINAL DATE EPI: s W* CITY OF SANFORD, F'LORIDA APPLICATION FOR BUILDING PERMIT I,1 0 N o. W 0 PERMIT ADDRESS ,774!2z. c y PERMIT NUMBER Total Contract Price of Job /dUM64%1;T/ rD00.0`0 Total Sq. Ft. 975'261 Describe Work e" mL X-Tazi-,&iAre- Type of Construction E t1 L- Flood Prone (YES) (NO Number of Stories Number of Dwellings Zoning - 2 Occupancy: Residential Commercial_ Industrial LEGAL DESCRIPTION (please attach printout from Seminole Count TAX I.D. NUMPER / - Z ® " .3 O - -!5-/ 2 - t7DOO /w:p OWNER ' ' PHONE NUMBER 3`3.1c2ADDRESSeA/di / _.eA G7- QyL_ CITY STATE -- ZIP TITLE HOLDER (IF OTHER THAN OWNER) ADDRESS CITY STATE ZIP BONDING COMPANY ADDRESS CITY STATE ZIP ARCHITECT ADDRESS CITY STATE ZIP MORTGAGE LENDER ADDRESS CITY STATE ZIP CONTRACTOR & - 2TElpZ OYP Ew PHONE NUMBER ADDRESS ST. LICENSE NUMBER C D(Q S3 CITY L2y-gt A STATE 2_ ZIP 32,-) Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL, PLUMBING, MECHANICAL, SIGNS, POOLS, ETC. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. A COPY OF THE RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL BE POSTED ON THE JOB SITE WITH PERMITS NO LATER THAN SEVEN (7) DAYS AFTER THE PERMIT HAS BEEN ISSUED. FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR THE IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. ACCEPTANCE OF PERMIT IS VERIFICATION THAT I WILL NOTIFY THE OWNER OF THE PROPERTY OF THE REQUIREMENTS OF FLORIDA LIEN LAW, FS713. Wigna 3 ro z Y/IZIQL. .% m 0 a O 1reofOwnr/Agent &_Da e Signature of Contractor & Date o o '< 1 rn a dCr- e or Pri t Owner/Agent Name T or Print Contractor's Name v x 0) o (u r- o ro o n Signat e of Notary & Date Signatur, of Notary & Date ~' 5 Official Seal) t RY •PLq!MARY L. MUSE ; MARY L. MUSE Y COMMISSION # CC 470040 '*; 1Y COMMISSION f! CC 470040 O J EXPIRES: August 4, 1999 `=;P EXPIRES: August 4, 1999 ro c Eorided ThN Notary Public Underwriters Bonded ThN Notary Public UndervrtiteB "Cl u - ..-- ---- —CO w o ° c E x ro o z I H rl ro w r 0 u o N a O N ? z w F Application Approv d Date: FEES: Building R do Police Fire Open Space Road Impact Ap ica ion PERMIT VALIDATION: CHECK CASH DATE IC7 / l BY ORIGINAL (BUILDING) YELLOW (CUSTOMER) PINK (COUNTY TAX OFFICE) GOL CO. ADMIN) THIS APPLICATION USED FOR WORK VALUED $2500.00 OR MORE OF CMCIIi I COlii 277534 7' IS-INSTAUIVIENT WAS PREPARED I3Y ND SHOULD BE RETURNEll r1-0: JOSEPI-I C. L. WETTACFI, ESQUIRE ZIMMERMAN, SI-IUFFIELD, KIS.ER SUTCLIFFE, P.A. Post Office Box 3000 Orlando, 17lorida 32502 PERMIT N0. STATE OF FLOPJDA COUNTY OF SEMINOLE 1_flli;Ui..l:_ i•UUi 1l `I. FL iE_;Oi;UEO-I VCI IE IE=E' c'f3 OC! f'fi ;t, TAX FOLIO NO. rl c,, D -t, CD - r-- lJ The undersigned hereby glvcs notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is pfoVidcd 111 thisNoticeofCollimericcrilent: 1 Description of property. 1 P I y. (Legal description and street address, ifavailable.) SEC ATTACHED EXi-I1131T "A" Having a street address of: 601-609 W. 27th Street and 2702-2710 French St. Sanford, Florida 32773. 2. General description of improvement: A 10,000 SQUARE FOOT WAREHOUSE/OFFICE FACILITY 3. Owncr infol-11, on: a. Name and address: ANGELO REALI and PIERINA R.E;ALI, 1390 Bristol Park Place Lake Mary, Florida 32746 b. Interest in property: fee sirllplc c. Nai is and address of fee sinlplc title holder (if other than Owrlcr): 4. Contractor (name and address) BUILDING EXPRESS 6 Z (, . (.1AeeP1A&- -( 4U;?. Lk- ti cLf i -1K /'''-/ L '3Z 7 `1` — a. Phonc Number V,(..q-3-(_) b. I7ax Nunlbcl (optional, il'service by Iilx is acceptable). 5. Surety: N/A a. Namc and address.- b. Phone Number C. Fax Number o Ptiorlal if service by fax is acceptable). d. Amount of bond: $ A copy ofthe Payment and Performance Bond is attached hereto as Exhibit RF'A11615XAIPJCW 6. Lender: (Name and address) SOUTHTRUST BANK, N.A. 135 Wcst Central Boulevard Orlando, Florida 32801 a. Phone Number 245-7122 b. Fax Number _ (optional, if service by fax is acceptable). 7. Persons within the State of Florida designated by 0\,V1le1- upon whom notices Or Other dOCUnleiltS may be served as provided by Section 713.13(1)(a)7., Florida Statutes: (Names and addresses) a. Phone Number b. Fax Number -----------(optional, if service by Iax is acceptable). 8. In addition to himself, Owner designates JOIN GRYSKIEWICZ, Vice President, of SOUTFITRUST BANK, N.A., 135 West Central Boulevard, Orlando, Florida 32801 to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes. a. Phone Number 245-7122 b. Fax Number (optional, if service by fax is acceptable). 9. Expiration date of notice of commencement (the expiration date is one year from the date of recording unless a different date is specified): rl ANGF1 0 REALI J rlcn PIERINA RLALI The foregoing instrument was executed, sworn to and acknowledged before me this October 1998, by ANGELO RLALI and PICKINA Rl ALI. SEAL) Signature Of Notary Public ZOO ' 0c, 11AV sondx3 "vt e4 (ia b ra J Glt)' S9EE! ) C uoissiwwo ( '` c to Cornmission CC733G57. Apt, Y si, Q J r e egiey J', ;,+' --- i'--rirrs-fr,.ril-;iEl-?40. Name'' t'`Notaiy Public Typed, Printed or Stamped) Personally Known OR Produced Identification Type of Identification Produced: izrnv6, i5xnii,.JCW 2 0 f;?i f f Il3I'i' A" PROPERTY That certain piece, parcel and tract oCland located in SEMINOLE County, Florida, described as follows.. THE EAST 250 FEET OF LOTS 1,2,3 AND 4, AMENDED PLAT OF DRUID PARK, ACCORDING TO THE PLAT THEREOF, RECORDED IN PLAT BOOK 7, PAGES 5 AND 6 OF THE PUBLIC RECORDS OF SEMINOLE COUNTY FLORIDA. Rla\\161SXMS/\.JC\V zi CITY OF SANFORD INSPECTIONS DIVISION COMMERCIAL REVIEW COMMENTS NEW CONSTRUCTION PROJECT:ixr nop,. 'otc5- DATE: iJuve % l`1 Q% ADDRESS: a 7V z SANFORD, FL CONTRACTOR: Dq/e LIC# C6C o60 6 5-3 ADDRESS: 3 6 PHONE REVIEW COMMENTS: 1. Finish floor elevation shall be 16 inches above center line of established street or a min. of 8' above grade when property has no paved street. City Sections 6-7. 2. Strip footers shall be continuous with 245 rebars for 1-story buildings, 2-story buildings shall have 345 rebars in footers, and #5 dowel at each corner. Size of footers shall be 8" x 16" min. for a 1-story and 10" x 20" for a 2 story. 3. Mono footer/slab combination shall be 20" deep and 16" wide with 45 degree angle into 4" slab. 2-story shall be 20" deep and 20" wide with 45 degree angle into 4" slab. Reinforcement shall be as in strip footer all laps a min. of 25 inches. 4. Masonry construction shall have a min. of 145 rebar in lintel course or tie beams. Vertical down rods shall be #5 rebar with 24" bend tied to lintel rebar and min. of 25" lap at eachdowelandtied. 4;1^ 5. Means of egress shall comply to Chapter 10, 1997 S.B.C. f r_ 6. Means of egress and illuminations shall comply to section 1016.1, 1016.2, and 1016.3 Exit Signs) 1997 S.B.C. k_Q— 7. All corridors shall be a minimum of 44", Table 1004, 1997, S.B.C. 8. All restrooms shall comply to 1997, H.C.F.S. 553, Part 5. 8-- 9 Interior finishes shall comply to Chapter 8, Table 803.3, 1997, S.B.C. E3_— 10. All electrical wiring service and fixtures shall comply to 1996 N.E.C. and Notice L amendments. 11. All plumbing shall comply to 1994, S.P.C. and 1997 F.S. 553, Part 5 Florida Accessibility Code 12. All mechanical equipment & duct systems shall comply to 1997, S.M.C. and 1997 Florida Enegry Code. 13. Firewalls or tenant separations shall comply to Sec. 413.3 & Table 704.1 & 704.1.4, 1997 S.B.C. All rated wall pentrations shall be sleeved and fire caulked. 14. Stairs shall comply to Section 1006,1007,1007.1.2,1007.3,1007.4;1007.5,1007.5.3,1007.6, 1007.7,1607.8,1008.6, & 1015, 1997 S.B.C. 15. Shall comply to 1994 N.F.P.A. -1. 16. Shall comply to Life Safety Code 101,1994. 17. Final grading inspection needs to be done after final grade but prior to final landscaping. g g' P g P p' g. Reviewed By: II 0 Ell CITY OF SANFORD BUILDING DEPARTMENT SUBMITTAL REQUIREMENTS FOR COMMERCIAL BUILDING PERMIT 1. Two (2) complete sets of plans and drawings to scale and to include; a. Site plan approved by Planning & Zoning and City Commission b. Boundary and building location survey C. Foundation plan d. Floor plan 1. Room or space identification 2. Indicate room dimensions 3. Specify door and window dimensions and types 4. Indicate tenant separation and fire resistant walls. Complete UL design noted. e. Four (4) or more elevations including finish floor(s) elevations. f. Structure details -signed and sealed by engineer g. Architectural drawings signed and sealed by architect h. Electrical drawings -signed and sealed by engineer, if over 600 amps i. Mechanical drawings -signed and sealed when 15 tons or more and/or 5,000.00 j. Plumbing drawings -signed and sealed, shall comply to Florida Handicap Code. 2. Plans shall show: a. Square Footage b. Type of construction c. Occupancy classification (group) d. Occupant load e. Sprinklers, standpipes and alarm systems f. Fire protection requirements & NFPA requirements g. Life safety Code 101 3. Three (3) sets of Florida Energy Forms 40OD-97 signed and sealed by architect or engineer. 4. Arbor permit when trees are to be removed from property. Contact the City Engineer for details regarding the Arbor Ordinance and permit. 5. Soil analysis may be included on site plan or foundation 6. Soil analysis and/or soil compaction report. If soils appear to be unstable or if structure to be built on fill, a report maybe requested by the Building Official or his representative. 7. Utility Letters Required Inspections During and Upon Completion of Construction 1. Footer 2. Underground electrical, mechanical and plumbing 3. Foundation elevation survey 4. Slab 5. Lintels -tie beams -columns -cells 6. Rough electrical 7. Rough mechanical 8. Rough plumbing 9. Tub Set 10. Framing II. Tenant separation/firewall 12. Insulation, walls and/or ceilings 13. Electrical final, mechanical final, and plumbing final 14. Building final 15. Other DATE 99 SIGNATURE Ld&o /;n By Owner or Authorized Agent)