Loading...
HomeMy WebLinkAbout3951 Night Heron Dr 18-4552 NEW SFHI I I'll I NO Vlu _-_ " Documented Construction Value: $ Job Address: 3951 Night Heron Drive, Sanford, FL 32773 CITY OF SANFORD LUIN & I-lKt: VKtVtN I 1UNVPERMITAPPLICATION Application No: )8 _S:- C' Historic District: Yes [1, No 0 Parcel ID: 17-20-31-502-0000-1970 Residential 2 Commercial F Type of Work: New 0 AdditionEl AlterationEl RepairEl DemoEl Change of UseEl MoveEl Description of Work: Construction of new single family residence Plan Review Contact Person: Michelle Parkison Phone: 407-529-3135 Fax: Name Street: City, State Zip: Title: Permitting Manager Email: mparkison(d)parksquarehornes.com Property Owner Information Phone: Resident of property? : No Contractor Information Name Park Square Homes/ Vishaal Gupta Phone: 407-529-3000 Street: 5200 Vineland Rd Suite 200 Fax: 407-529-3001 City, State Zip: Orlando, FL 32811 State License No.: CRC1330351 Arch. / MJS Home Designs Arch itect/Eng i neer Information Arch. 407-629-6711 Name: Eng. / Don Bolden Eng. Phone: Eng. 386-668-7606 Arch./ 250 N. V\Iymore Rd. Suite B Winter Park FL 32789 Street: Eng./ PO Box 530783, Deba[y FL 32753 Fax: City, St, Zip: Bonding Company: Address: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5' Edition (2014) Florida Building Code Revised: June 30,2015 5 , Pennit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. pso— it - IF3. Signature ofOwner7Agent Date Vishaal Gupt Print Owner/Agent offlorida , _ _. Date MICHELLE PARKISON Notary Public - State of Florida Commission 4 GG 157861 My Comm. Expires Nov 5, 2021 Bonded ihrough Nationel Notery Assn, to Me or Produced ID Type of ID I\ - v7). 11 Signature ofContractor/Agent Date Vishaal Gu Print Contraclaf7? I - I E) -(e) ADate MICHELLE PARKISON Notary Public - State of Florida 157861 M1 —61" Commissioin 4 GG My Comm. Expires Nov 5, 2021 BondfA irou,h Nitiomil Notziry Ms,; VIA trac'*' w A2e ntis Pe=sonally Known to Me ortor Produced ID _ Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building[k Electricala MechanicaIR Plumbinga GasF] Roof[:] Construction Type: V6 Occupancy Use: Flood Zone:)(-It-E Total Sq Ft of Bldg: -3 34: Min. Occupancy Load: # of Stories: Z— Por —IAC-Hip New Construction: Electric - # of Amps 214 Fire Sprinkler Permit: YesF No T # of Heads APPROVALS: ZONING: 4. 12- /-9 Jg— UTILITIES: ENGINEERING: k-rr- 11-5-15 FIRE: COMMENTS: _ Ok to construct single family home with setbacks and impervious area shown on plan. 13Arelo-14-C 2c- 9,% nts e, - it "et A + 1 3 -1. &11 I -se , Plumbing - # of Fixtures 1, ( Fire Alarm Permit: YesF] NoE WASTE WATER: BUILDING:- 9::- f Revised: June 30, 2015 Pennit Application CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION L)s LApplicationNo: U Documented Construction Value: $ 154, 200 Job Address: 3951 Night Heron Drive, Sanford, FL 32773 Historic District: YesEl NoV Parcel ID: 17-20-31-502-0000-1970 Residential [id Commercial [] Type of Work: New 0 AdditionEl AlterationEl RepairEl DemoEl ChangeofUsen MoveEl Description of Work: Construction of new single family residence Plan Review Contact Person: Michelle Parkison Phone: 407-529-3135 Fax: Name Street: City, State Zip: Title: Permitting Manager Email: mparkisoneparksquarehomes.com Property Owner Information Phone: Resident of property? No Contractor Information, Name Park Square Homes/ Vishaal Gupta Phone: 407-529-3000 Street: 5200 Vineland Rd Suite 200 Fax: 407-529-3001 City, State Zip: Orlando, FL 32811 State License No.: CRC1330351 Arch. / MJS Home Designs Arch itect/Engineer Information Arch. 407-629-6711 Name: Eng. / Don Bolden Eng. Phone: Eng. 386-668-7606 Arch./ 250 N. Wymore Rd. Suite B Winter Park FL 32789 Street: Enq./ PO Box 530783, Deba[y FL 32753 - Fax: City, St, Zip: Bonding Company: Address: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certif that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30,2015 Pennit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. ke 11-IF3-16 — Signature ofOwner7Agent Date V"I- wir-). Ve) Signature of Contractor/Agent Date Vishaal Gupta Vishaal Print 0%vner/Agent'sNa-m-e-----, Print Contrai 11. 15. 1& — relof Notary -State of Florida Date MICHELLE PARKISON X,,%s Pu INotaryPublic — State of Florida Commission # GG 157861 s v 0MyComm. Expires Nov 5, 2021mmE h,..g" a".'"J O"ry s' Bonded thfough Nafiallil Nolary Assn. to Me or Produced ID Type of ID Si e ate MICHELLE PARKISON FloridaNotaryPublic — State of Commission 9 GG 157861 z My Comm. Expires Nov 5, 2021 Bond=Dugh National NotarlAw; 4 ContractoiTAgent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: BuildingEl ElectricalF] --Mechanical[] PlumbingF] GasE] RoofF1 Construction Type: Occupancy Use: Flood Zone: - Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps of Stories: Plumbing - # of Fixtures, Fire Sprinkler Permit: Yes F] No F] # of Heads Fire Alarm Permit: Yes [] No APPROVALS: ZONING: UTILITIESJi/_ '11frteWASTt WATER: ENGINEERING: FIRE: BUILDING: COMMENTS: Revised: June 30,2015 Permit Application 19L- LA ±E>5 -2- COUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 18100009 BUILDING APPLICATION #: 18-10000907 BUILDING PERMIT NUMBER: 18-10000907 DATE: November 15, 2018 3'k) 06 UNIT ADDRESS: NIGHT HERON DRIVE 3951 17-20-31-502-0000-1970 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG., SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: PARK SQUARE ENTERPRISES LLC ADDRESS: 5200 VINELAND ROAD STE 100 ORLANDO FL 32811 LAND USE: SINGLE FAMILY RESIDENCE TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 3951NIGHT HERON DRIVE / WYNDHAM PRESERVE / SFR FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUETYPEDISTSCHEDRATEUNITSTYPE ROADS-ARTERIALS CO -WIDE ORD Single FamilyROADS -COLLECTORS HousingNl. 705.00 1.000 dwl unit 705.00 Single Family Housing 00 1.000 dwl unitFIRERESCUEN/A 00 LIBRARY CO;WIDE ORD 00 Sin le Family SCHOO S Housing 54.00 1.000 dwl unit 54.00 single Family PARKS CO:WIDE ORD Housing 9,000.00 1.000 dwl unit 91000.00N/A LAW ENFORCE N/A 00 DRAINAGE N/A 00 010 AMOUNT DUE 9,759.-00 PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THESEMINOLECOUNTYROAD, FIRE,/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY. RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE DATE ABOVE, BUT NO LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE BUSINESS OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT. r THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT ISSUED WITHIN 60 CALENDAR DAYS FROM THE DATE ABOVE () Name: Daphne Clark Firm: Park Square Homes Address: 5200 Vineland Road, Suite 200 City: Orlando State: FL Zip Code: 32811 Phone:, 407-257-6940 Fax: Email: parksquare@permitspermitspermits.com Property Address: 3951 Night Heron Drive Property Owner: Park Square Enterprises, LLC Parcel identification Number: 17-20-31-502-0000-1970 Phone Number: 407-529-3000 Email: The reason for the flood plain determination is: FQ-1 New structure Existing Structure (pre-2007 FIRM adoption) F-1 Expansion/Addition Existing Structure (post 2007 FIRM adoption) Pre 2007 FIRM adoption = finished floor elevation 12" above BFE Post 2007 FIRM adoption finished floor elevation 24" above BFE (Ordinance 4360) pM kp, p Yp' S1IIA $ - - , 11 - 161,p;11,ip@ IUNLY11,91'alsdow- U, Flood Zone: X Base Flood Elevation: N/A Datum: N/A FIRM Panel Number: 120294 0090 F Map Date: Sept. 28, 2007 The'referenced Flood Insurance Rate Map indicates the following: F-1 The parcel is in the: F-1 floodplain F-1 f loodway F-1 A portion of the parcel is in the: F-1 floodplain 0 floodway FE -31 Theparcelisnotinthe: FE-31floodplain F-Ifloodway 0 The structure is in the: Ofloodplain F-Ifloodway El The structure is not in the:E] floodplain F-1 floodway If the subject property is determined to be flood zone 'A', the best available information used to determine the base flood elevation is: BP# 18-4552 Reviewed by: Michael Cash, CFM Date: December 5, 2018 I I P I Application for Paved Driveway, Sidewalk or 2oyo'kw "i 14 Walkway Including Right -of -Way Use & I A ; 0; k4- f 1A1 N —IL877—'-f a" a%,0JJ "U " id -V cy www.sanfordfl.gov Department of Planning & Development Services 300 North Park Avenue, Sanford, Florida 32771 Phone: 407.688.5140 Fax: 407.688.5141 This permit authorizes work to be done on the subject property or in the City of Sanford's right-of-way in accordance with the City's regulations and the attached construction plans approved as part of this permit. The permit is required for driveway or sidewalk construction over 100 square feet of concrete or other material on the subject parcel and / or any construction of a driveway, walkway or landscape improvements within the city right-of-way. It does not approve any work within any other jurisdiction's right-of-way. All requested information below as well as a current survey, site plan or plat clearly identifying the Know what's below. size and location of the existing right-of-way and use shall be provided or application could be delayed. Call before you dig. 1. Project Location/Address: -:tq6l 7-L 2. Proposed Activity: FX_1 Driveway E]Walkway F-] Other: 3. Schedule of Work: Start Date Completion Date El Emergency Repairs 4. Brief Description of Work: Construction of new driveway for new single family residence This application is submitted by: Property Owner Signature: - V 1___' Address: 5200 Vineland Rd Suite 200 Orlando, FL 32811 Print Name: Vishaal Gupta Phone: (407)r529-3135 Fax: Email: mparkison@parksqua Irehomes.com Date: Maintenance Responsibilitieslindemnification The Requestor, and his successors and assigns, shall be responsible for perpetual maintenance of the improvement installed under this Agreement. This shall include maintenance of the improvement and unpaved portion of right-of-way adjacent thereto. Requestor may, with written City authorization, remove said installation/improvement fully restoring the right-of-way to its previous condition. In the event that any future construction of roadways, utilities, stormwater facilities, or any general maintenance activities by the City becomes in conflict with the above permitted activity, the permittee shall remove, relocate and/or repair as necessary at no cost to the City of Sanford insofar as such facilities are in the public right-of-way. If the Requestor does not continuously maintain the improvement and area in accordance with previously stated criteria, or completely restore the right-of-way to its previous condition, the City shall, after appropriate notice, restore the area to its previous condition at the Requestor's expense and, if necessary, file a lien on the Requestor's property to recover costs of restoration. To the fullest extent permitted by law, Requestor agrees to defend, indemnify, and hold harmless the City, its councilpersons, agents, servants, or employ- ees (appointed, elected, or hired) from and against any and all liabilities, claims, penalties, demands, suits, judgments, losses, expenses, damages (direct, indirect or consequential), or injury of any nature whatsoever to person or property, and the costs and expenses incident thereto (including costs of defense, settlement, and reasonable attorney's fees up to and including an appeal), resulting in any fashion from or arising directly or indirectly out ofor connected with the use of the City's right-of-way. I have read and understand the above statement and by signing this application I agree to its terms. Signature: Date: This permit shall be posted on the site during construction. Please call 407.688.5080 24 hours in advance to schedule a pre -pour inspection. Pre -pour Inspection by: Date: Application No: Reviewed: Public Works Official Use Only Fee: Utilities rk F Approved: —VLJ-- Engineering _NLI Site Inspected by: Special Permit Conditions: Date: Date: Date: Date: . 1-1-5-2618 Date: November 2015 Kow use unveway.pa 1111go 1,111, 1 i;ii:iii i Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: IN. V5 - IE, I hereby name and appoint: an agent of - David Mercer Park Square Homes Name of Company) to be my lawful attomey-in-fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): 0 The specific permit and application for work located at: C5 1 tA' *,k \4e—,rc>tA -\`ir-tye- , C-rci Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: Vishaal Gupta State License Number: CRC1330351 Signature of License Holder: STATE OF FLORIDA COUNTY OF Orange The foregoing instrument was acknowledged before me this _L'5 day of tAOV 3 200 k e> by Vishaal Gupta who is Xpersonally known to me or o who has produced as identification and who did (did not) take an r S(jr e - - Notary Seal) MICHELLE PARK18ON u Stale FloodaNotaryPublic — Stale olFlorida C C My Corn,nission # GG 157861 0 " P'r s v IrnMyCom. Expires Nov 5, 202100 0, ded 1111ough Notional Notary Assn, N N, "" A.. Rev. 08.12) M -VC \—V \\12\,,,X V-, Print or type name Notary Public - State of Vkc>-r'% Commission No.Q-pG My Commission Expires: V5 - PCG—A RECORD COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 197 Barcelona C RHG Office - W Builder Name: One Stop Cooling and Heating Street: \ %TC>"_'- Pe mi Office: C SgfordrI 0ul: City, State, Zip: Sanford , FL Pe mi Numbert r: 4 5 52 Owner: Park Square Homes Jurisdiction: 691500 Design Location: FL, Orlando County: Seminole (Florida Climate Zone 2 1 . New construction or existing New (From Plans) 9. Wall Types (2911.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=1 1.0 1521.00 ft2 b. Concrete Block - Int Insul, Exterior R=4.1 1185.30 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=1 1.0 205.33 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1485.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1485.00 ft2 6. Conditioned floor area above grade (ft2) 2413 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(313.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 482.6 a. U-Factor: Dbl, U=0.55 210.00 ft2 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.58 64.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 47.0 SEER:16.00 c. U-Factor: Dbl, U=0.54 39.00 ft2 SHGC: SHGC=0.25 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 45.5 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 2.384 ft. Area Weighted Average SHGC: 0.230 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2413.0 sqft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 1186. 00 ft2 b. Conservation features b. Floor Over Other Space R=0.0 928.00 ft2 None c. other (see details) R= 299.00 ft2 15. Credits Pstat Glass/Floor Area: 0.130 Total Proposed Modified Loads: 68.37 PASSTotalBaselineLoads: 72.29 1 hereby certify that the plans and specifications covered by Review of the plans and 011 14E S 7.43" this calculation are in compliance with the Florida Energy specifications covered by this AV Code. Bojan Digitally signed by Boian calculation indicates compliance 00 Paukovic Date: 2018.11.09 16:03:32 with the Florida Energy Code. 1001 PREPARED BY: Paukovic Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 V I hereby certify that this building, ned, is in compliance Florida Statutes. with the Florida Ene g 0 W'E OWNER/AGE . .. 0Zr,z= BUILDING OFFICIAL: DATE: 7 DATE. Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 11/9/2018 3:56 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page I of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 197 Barcelona C RHG Off Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 2413 Lot # 197 Owner Name: Park Square Homes Total Stories: 2 Block/Subdivision: WP of Units: 1 Worst Case: No PlatBook: Builder Name: One Stop Cooling and Heatin Rotate Angle: 90 Street: Permit Office: City of Sanford Cross Ventilation: No County: Seminole Jurisdiction: 691500 Whole House Fan: No City, State, Zip: Sanford , Family Type: Single-family FL , New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TIVY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Orlando FL ORLANDO_INTL—AR 41 91 70 75 526 44 Medium BLOCKS Number Name Area Volume 1 Blockl 2413 22072.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 1186 11029.8 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 1227 11043 No 4 3 1 Yes Yes Yes FLOORS y# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor 2nd Floor ---- ---- 132 ft2 11 0.29 0 0.71 2 Floor over Garage 2nd Floor ---- ---- 167 ft2 11 0.29 0 0.71 3 Slab-On-Gracle Edge Insulatio 1st Floor 127 ft 0 1186 ft2 0.29 0 0.71 4 Floor Over Other Space 2nd Floor ---- ---- 928 ft2 0 0.29 0 0.71 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. deg) 1 Hip Composition shingles 1661 ft2 0 ft2 Dark 0.9 N 0.9 No 0 26.6 ATTIC V# IRCCTypeVentilationVentRatio (1 in) Area RBS 1 Full attic Vented 300 1485 ft2 N N 11/9/2018 3:56 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 2 of 5 ILI 1:11 k &*4 1] kyj I kh FAMAUSI: CEILING V# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) 1 st Floor 30 Blown 1485 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belowy # Ornt Tn Will Type Space B-V;;l1 IP Ft In Et in Arpi R-V;;Iijp Frqrt'nn Ahqnr rqrJP.% 1 N=>E Exterior Frame - Wood 2nd Floor 11 30 0 9 0 270.0 ft2 0 0.25 0.8 0 2 N=>E Exterior Concrete Block - Int Insul 1 st Floor 4.1 30 0 9 4 280.0 ft2 0 0 0.8 0 3 E=>S Exterior Frame - Wood 2nd Floor 11 54 6 9 0 490.5 ft2 0 0.25 0.8 0 4 E=>S Exterior Concrete Block - Int Insul 1st Floor 4.1 44 6 9 4 415.3 ft2 0 0 0.8 0 5 S=>W Exterior Frame - Wood 2nd Floor 11 30 0 9 0 270.0 ft2 0 0.25 0.8 0 6 S=>W Exterior Concrete Block - Int Insul 1st Floor 4.1 8 0 9 4 74.7 ft2 0 0 0.8 0 7 W=>N Exterior Frame - Wood 2nd Floor 11 54 6 9 0 490.5 ft2 0 0.25 0.8 0 8 W=>N Exterior Concrete Block - Int Insul 1st Floor 4.1 44 6 9 4 415.3 ft2 0 0 0.8 0 9 NE Garage Frame - Wood 1st Floor 11 22 0 9 4 205.3 ft2 0 0.25 0.8 0 DOORS V Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 S=>W Insulated 1st Floor None 39 3 8 24 ft2 2 -=>NE Wood 1st Floor None 39 2 8 8 2 1 .3 ft2 WINDOWS Orientation shown is the entered orientation (=> chan2ed to As Built rotatecl 90 diegrees). V Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>E 1 Metal Low-E Double Yes 0.55 0.22 N 30.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds None 2 N=>E 2 Metal Low-E Double Yes 0.55 0.22 N 30.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds None 3 N=>E 2 Metal Low-E Double Yes 0.58 0.25 N 64.0 ft2 7 ft 4 in 1 ft 4 in None None 4 E=>S 3 Metal Low-E Double Yes 0.55 0.22 N 45.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds None 5 E=>S 4 Metal Low-E Double Yes 0.55 0.22 N 45.0 ft2 1 ft 0 in 11 ft 0 in Drapes/blinds None 6 E=>S 4 Metal Low-E Double Yes 0.54 0.25 N 4.0 ft2 1 ft 0 in 11 ft 0 in Drapes/blinds None 7 S=>W 5 Metal Low-E Double Yes 0.55 0.22 N 15.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds None 8 S=>W 5 Metal Low-E Double Yes 0.54 0.25 N 4.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds None 9 S=>W 5 Metal Low-E Double Yes 0.54 0.25 N 12.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds None 10 W=>N 7 Metal Low-E Double Yes 0.55 0.22 N 30.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds None 11 W=>N 7 Metal Low-E Double Yes 0.54 0.25 N 15. 0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds None 12 W=>N 8 Metal Low-E Double Yes 0.55 0.22 N 15. 0 ft2 1 ft 0 in 11 ft0in Drapes/blinds None 13 W=>N 8 Metal Low-E Double Yes 0.54 0.25 N 4.0 ft2 8ft0in 1 ft 4 in Drapes/blinds None 11/9/2018 3:56 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE V# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 455 ft2 455 f12 64 ft 9.3 ft 1 - INFILTRATION Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000407 2575.2 141.37 265.87 .3778 7 HEATING SYSTEM 7 # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:9 45.5 kBtu/hr 1 sys#1 COOLING SYSTEM 7 # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 47 kBtu/hr 1410 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # Supply ---- Location R-Value Area Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 482.6 ft Attic 120.65 Prop. Leak Free 2nd Floor --- cfm 72.4 cfm 0.03 0.50 1 1 11/9/2018 3:56 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 4 of 5 FnRM R4n.c;-?nl7 INPI IT R1 IMMARV rHFrKI I-qT PFPORT TEMPERATURES Prograrnable Thermostat: Y Ceiling Fans: Coollng a, b Mar Apr Ma y Jun Ju Aug Sep Oct Nov Dec Hea t ng H Jan F .b Mar Apr May Jun X Juxl Aug Sep Oct NovN DecHVentingJanFebXxMarAprMayJunJuliAugSepOctNovDec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 1 st Floor Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 2nd Floor Name: Test Rater Rating Compant: Test Rater Signature: Date: 11/9/2018 3:56 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 5 of 5 Florida Building Code, Energy Conservation, 6th Edition (2017) MandatorV Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Sanford , FL , Permit Number: MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL r-1 R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card'be completed and certified by the builder to be accurate and correct before1inal approval of the building for occupancy. Florida law Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelof)be building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. D R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. EiR402.4.3 Fenestration air leakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm persquarefoot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/ WDIVIA/CSA I bi/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 11/9/2018 3:56 PM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ri R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1 . Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. F R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall -be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or 7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. MR403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105oF (41oC) or below 550F (1 30C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall bereadily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 11/9/2018 3:56 PM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 112 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). F R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 1 OOOF to 140'F (38'C to 60'C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied toF-1 electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. 0 R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-leating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. F1 R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. F] R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other appro ved means of ventil ation- including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gmvity:darnpers thW close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. El R403.6.2 Ventilation air., Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1 . The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-1 1 and the ceiling shall be insulated to a minimum of R-1 9, space permitting, or R-1 0 otherwise. R403.7 Heating and cooling equipment (Mandatory). El R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM) MINIMUM EFFICACy a CFM/WATT) AIRFLOW RATE MAXIMUIV CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt 90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 11/9/2018 3:56 PM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) E] R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1 Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. mR403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. El R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. 0 R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on anF1intermittentbasis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1 . A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, El shall include automatic controls capable of shutting off the system when the pavement temperature is above 50OF (11 OOC), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 401F (4.81C). E R403.1 0 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.1 0.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions:, 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste- heat-recove ry pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 11/9/2018 3:56 PM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. F1 R403.11 Portable spas (MandatorY)he energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 11/9/2018 3:56 PM EnergyGauge(D USA - FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-fami b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity ... 47.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2413 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-f actor: (weighted average) 7a. 0.555 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.230 14. Heating system: Capacity___A5.5 c) Area 7c. 313.0 a) Split system heat pump HSPF 9.0 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor: (weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) gb. 11.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.90 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 11.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 1 OA2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (insulation R-value) 110132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed base Iled code compliant features. Builder Signature: r Date: Address of New Home: City/FL Zip: Sanford, FL 11/9/2018 3:56:31 PM EnergyGauge@ USA 6.0.02 - FaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 197 Barcelona C RHG Office - W Builder Name: One Stop Cooling and Heating Street: Permit Office: City of Sanford City, State, Zip: Sanford , FIL , Permit Number: Y 0 Owner: Park Square Homes Jurisdiction: 691500 Lu Design Location: FL, Orlando COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall t-.YtP.nrJ behind pip'no and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior w all tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between f re sprinkler cover olates and walls 0 ceilino a. In addition, inspection of log walls shall be in accordance with the prov of ICC-400. 11/9/2018 3:56 PM EnergyGauge@ USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft- Project Summary Entire House One Stop Cooling and Heating 7225 Sardscove Court, Wirter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.00nn License: CAC032444 For: Park Square Homes FL Notes: Job: Lot 197 Barcelona C RHG Date: 07/02/2017 By. LF/LM Plan: RHG Weather: Orlando Executive AP, FL, US Winter Design Conditions Summer Design Conditions Outside db Inside db Design TD 44 OF 68 OF 24 OF Heating Summary Structure 20697 Btuh Ducts 3299 Btuh Central vent (0 cfm) 0 Btuh gone) Humidification 0 Btuh Piping 0 Btuh Equipment load 23996 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Coolinq Area (ft2) 2505 2505 Volume (ft3) 22898 22898 Air changes/hour 0.41 0.21 Equiv. AVF (cfm) 156 80 Heating Equipment Summary Make Trane Trade TRANE Model 4TWR6048H1 AHRI ref 7563627 Outside db 93 OF Inside db 74 OF Design TD 19 OF Daily range L Relative humidity 50 Moisture difference 46 grAb Sensible Cooling Equipment Load Sizing Structure 22667 Btuh Ducts 11232 Btuh Central vent (0 cfm) 0 Btuh none) Blower 0 Btuh Use manufacturer's data n 1Rate/swin multiplier 0.98 F-Equipmeril Sensible load 33086 Btuh Latent Cooling Equipment Load Sizing Structure 3289 Btuh Ducts 2317 Btuh Central vent (0 cfm) 0 Btuh none) Equipment latent load 5606 Btuh Equipment Total Load (Sen+Lat) 38692 Btuh Req. total capacity at 0.75 SHR 3.7 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TWR6048H1 Coil TEM6A0D48H41 ++TDR AHRI ref 7563627 Efficiency 9 HSPF Efficiency 13.0 EER, 16 SEER Heating input Sensible cooling 35250 Btuh Heating output 45500 Btuh @ 47'F Latentcooling 11750 Btuh Temperature rise o OF Total cooling 47000 Btuh Actual air flow 0 cfm Actual air flow 1567 cfm Air flow factor 0 cfrn/Btuh Air flow factor 0.046 cfrn/Btuh Static pressure 0.50 in H20 Static pressure 0.50 in H20 Space thermostat Load sensible heat ratio 0.86 Capacity balance point = 28 OF Calculations approved byACCA to meet all requirements of Manual J 8th Ed. f'd- 2018-Nov-09 15:52:54 Righ-Suite@ Universal 2018 18.0.31 RSU1 6877 Page 1 MP PRINT\Lot 197 Barcelona C RHG Office - W.rup Calc= MA House faces: W Job: Lot 197 Barcelona C RHG OffiFjd- wrightsoft, Right-J@ Worksheet Date: 07/02/2017EntireHouse By: LF/LM One Stop Cooling and Heating Plan: RHG 7225 Sandscove Gourt, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.0r)eStopCoolir)g.00m License: CAC032444 1 Room name Entre House FOY 2 Exposed wall 296.0 ft 17.5 ft 3 Room height 9.1 It d 9.3 If heatl000l 4 Room dimensions 1.0 x 168.0 If 5 Room area 2504.5 ft' 168.0 f12 Ty Construdion U-value Or HTM Area (ft2) Load Area (ft2) Load number BtuW'F) Btuh/ft2) or perimeter (ft) 8tuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 2 31f Aft 2 4 491- 028 286 0 0 0 0 4A5-,26m b 5 50 nb 13.09 45 0 589, 00 1 0 0 0 13A-4ocs 0.143 ne 3.40 3.00 414 365 1242 1093 0 0 0 0 4A5-2om 0.550 ne 13.09 2224 45 0 589 1001 0 0 0 0 11 4135-2fm 0.540 ne 12.85 23.69 4 0 51 95 0 0 0 0 iy , - I -0sw 0 097 se, 231 2.89 I 270 239 J.j"''562 690p 0 k - 1 -- 0 A'o 0550 13 '09 21 91 1 196 329 0 0 0 G 4 5 2fm%"' B b se- 2i'97 4 1 51 88 0 0 o 41]i!2fm 01540 R-,,',12.85 722 2 12 2 5 2 3 t-D 1 3A-4ocs 0.143 se 3.40 3.00 74 50 172 151 74 50 172 151 11DO 0.390 se 9.28 12.54 24 24 223 301 24 24 223 301 12B-0sw, 1 AA5`26rh-".' , 097 sW, 13.09 2.89 21.91 1 '491 30 0 446 3 I M8 1286 657 0 0 0 b 0.5,40 N 12.85, 3. 2,- 1 193 350 0 0 w 13A-4ocs 0.143 sw 3.40 3.00 414 395 1344 1183 88 73 Z50 220 4A5-2orn 0.550 sw 13.09 22.70 15 0 196 341 15 0 196 341 4135-2frn 0.540 sw 12.85 13.78 4 4 51 55 0 0 0 0 1213-0sw- 0 00 nh,, 31 89 270 7'2-40 554 N' '-693: 0 0 AA5 2cm F 0.550 nw- 13.09 2224 36 0" 11-6 67 1 0 0 13A-4ocs 0.143 nw 3.40 3.00 279 185 630 554 0 0t:Gs 4A5-2om 0.550 nw 13.09 22.24 30 0 393 667 0 0 0 0 AA5-2omd 0.580 nw 13.80 27.82 64 0 883 11780 0 0 0 0 0, 0 ------- c12 -Osw o.b i ni- T 217 1.57---- 205 183 397 2 8 0 0 3600 28 12. 54 21 267 90a 0 0 0 C 1613-3-0ad,' 0.032 0.76 1.78 1489 1489 1134 2652 0 0 0 0 9A706 SCP',, 0.295 2b%:-, 132 12 0 b IF 19C-19csco 0.049 0.40 0.32 166 166 67 52 0 0 0 0 F, t-m,' p 1 -.1-80 J.00 1 1 i't 27 350 b 188 18 4 0 7 M k T)"' A" r'n' MT U kAi Z" A, 5 K 7W k T 6 c) AED excursion 344 51 Envelope loss/gain 16617 18414 1332 1063 12 a) Infiltration 4080 1633 246 98 b) Room venblation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances bther 1700 0 Subtotal (lines 6 to 13) 1 20697 22667 15771 1161 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 1577 1161 14 Subtotal 20697 22667 0 0 15 Ductloads 1 16% 50% 3299 11232 16% bU/. 0 0 Total room load 23996 0 0 Air required (dm) 00 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. FW 2018-Nov-09 15:52:54 A ZK RigN-Suite(SUNversal 2018 18.0.31 RSU1 6877r-- MP PRINT\-ot 197 Barcelona C RHG Office - W.rup Calc = MJ8 House faces: W Page 1 d - Job: Lot 197 Barcelona C RHG OffirFwrightsoft, Right-JO Worksheet Entire House Date: 07/02/2017 LF/LM One Stop Cooling and Heating 8P a n: RHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: www.OneStopCoolirig.com License: CAC032444 1 Room name LOFF DIN 2 Exposedwall 16.0 It 34.5 It 3 Room height 9.0 ft heat/cool 9.3 ft heaV000l 4 Room dimensions 1.0 x 281.8 ft 14.0 x 13.0 It 5 Room area 281.8 ft2 182.0 1112 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number Btuh/ft2--9 Btuh/ft2) or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VL,, 1213-0-sw AA5- 6.097 ne' 320 o 0 G 2o M-, 5060 ne: 3.09 22.24 15 0 0 0 0 0 VL213A-4ocs 0.143 ne 3.40 3.00 0 0 0 0 70 70 237 209 4A5-2om 0.550 ne 13.09 2224 0 0 0 0 0 0 0 0 11 4135-2frn 0.540 ne 12.85 23.69 0 0 0 0 0 0 0 0 1213 G 7, sYV, 4A5-26m A097 0'550 s6 se, 2.31 3.09 4 'M9 21'91 0 0 0 0 0 0 0 0 0 0 0 0 G 4135-2fm 6540 se"`l 1 b 0 0 1 85 1' 729 0 0 0 0 0 0 4135-26"t':-, 0. w 0 0 0 0 Y-D 13A-4ocs 0,143 se 3.40 3.00 0 0 0 0 0 0 0 0 1 1DO 0.390 se 9.28 12.54 0 0 0 0 0 0 0 0 12B 597 0 550 sw - 2.31 A'.09 2.80 1721 1911 18 I'll",.O",.,,,,,,-O"- T'K 1'8 I'll 2 Al 2 0 0 0 04A5-2om 0'!4b 1285, 23.32 i- 0 co 0 --0 4" 0, 0 0 o 13A-4ocs 0.143 sw 3.40 3.00 0 0 0 0 121 121 411 362 4A5-2om 0.550 sw 13.09 22.70 0 0 0 0 0 0 0 0 4135-2fm 0.540 sw 12.85 13.78 0 0 0 0 0 0 0 0 2B'-0 s'w" 77" 0.697 n-w 2.31 Z89 t 0 0 o b 0 0 L d 4A5-2om' 0.550 nw 1 b4 2224 b b b b N- , 0 13A-4ocs 0.143 nw 3.40 3.00 0 0 0 0 130 100 341 300 4A5-2om 0.550 nw 13.09 2224 0 0 0 0 30 0 393 667 4A5-26md nw 13.80 27.82 0 0 0 0 0 0 li"- 12C10sq, 'l 0ogi 217 1'.87 0 0 fv" 0k " 0 w 0T 01P Q-b, d LLL'4-"'D 1'1 DO ':," ' 390, T: 9.28 0 0 A o 0 b o 4, 0 0 C 1613-30ad 0.032 0.76 1,78 282 282 215 502 176 176 64 313 F"' A 0 scpll9," b' 2 64 b62 0 0, 0 0 0 19C-19c= 0.049 0.40 0.32 6 6 2 2 0 0 0 0 S 1.180 28 '68 0.00 0 V 0 0 0 7 7,: b N A V Z 7% P A .11, a- 41, X"A' A, r- _v, n "f 1---,U TL F X71 UIIM-,' v Y' , 6 c) AED excursion 55 147 Envelope loss/gain 711 1154 2485 1998 12 a) Infillration 217 87 484 194 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 928 1241 2970 2192 Less external load 0 0 0 0 Lesstransfer b 0 0 0 Redistribution 141 245 0 0 14 Subtotal 1070 1487 2970 2192 15 Duct loads 16%1 509/61 171 737 1 50%1 473 1086 Total room load 1240 2223 3443 321fl78 Air required (cfm) 01 1031 0 1 22 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2018-Nov-09 15:52:54 Rig1ht-Suite@ Unversal 2018 18.0.31 RSU1 6877 Page 2 MP PRINT\Lot 197 Barcelona C RHG Office - W.rup Cafe = MJ8 House faces: W id L Job: Lot 197 Barcelona C RHG Offl 93- wrightsoft, Right-JO Worksheet Date: 07/02/2017EntireHouse B - LF/LM One Stop Cooling and Heating Mn: RHG 7225 Sandscove Court, Winter Park, FL 32792 Phc)ne: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wvvw.OneStopCooling.com License: CAC032444 1 Room name GATH KIT 2 Exposed wall 32.0 ft 11.5 ft 3 Room height 9.3 ft heat/cool 9.31 ft heat/cool 4 Room dimensions 1.0 x 286.0 It 13.5 x 11.5 ft 5 Room area 286.0 tF 155.3 ft' Ty Construction U-value or HTM Area OF) Load Area (ft2) Load number Btuh4l2-0F) Btuh/ft2) or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W-- 1213-0sw 0.60 231 289 0 0 0 0-- 0 0.550 ne" 13'69 22'24 0 0 b A 0 0 0 13A-4ocs 0.143 ne 3.40 3.00 149 119 404 356 0 0 0 0 4A-5-2om 0.550 ne 13.09 2224 30 0 393 667 0 0 0 0 11 4135-2fin 0.540 ne 12.85 23.69 0 0 0 0 0 0 0 0 1 213-0sw 0.097 se"' 2.31 2.89 0 0 0' 0 I'_0 0 j J1,11, 0W, I..' -Q 0.550-7 sea 3.09 21 911 0 b 0 x! 0 0 o 0 0 4135 2fm'" 0.540 se'' 1285 b-' 0 0 0 0 0 0 G 4 135 -2hh,:': A 2.85 22.72 0 7 'b 0 0 i--0 0 VL-D 40cs1113DAO 0.143 se 3.40 3.00 0 0 0 0 0 0 0 0 0.390 se 9.28 12.54 0 0 0 0 0 0 0 0 V A 2B "b R o.667-,, 0,550 sw 31 3 09 2.8 9 2191 0 0 10 0 V-" b 0 b 0 7= f o 0 7` "b 0" b 0 0 0 4135-2ft"`--, I I -- -y 0' .5 '40II l-'M 2.85 q:-21 2 0 70 0 0 0 0 0 13A-4ocs 0.143 s 3.4b 3.00 0 0 0 0. 107 1b7' 364 izu 4A5-2om 0.550 sw 13.09 22.70 0 0 0 0 0 0 0 0 4135-2fm 0.540 sw 13.78 0 0 0 0 0 0 0 V,- J-2-13-0 0.097 6.550 nw, 2.31 2.89 2 0 0 0 0 0 A' 0 0 0 G 4A6-2 om' nw 1 3 66 22 4 If 1"o lc , - 0 I - 0 0 a-0- 0 0 0.143 nw 3.40 3.00 149 85 289 254 0 0 0 0 tj13A-4ocs 4A5-2om 0.550 nw 13.09 2224 0 0 0 0 0 0 0 0 G 4A5-2omd 0.580 nw 13.80 27.82 64 0 883 1780 0 0 0 0 R:'4-- 1 -2 C "0 s-W' 0 09"1' 0 b Z% A" 0 0 b 11W, n 9.' 1 54 0-- o 0 o 0 10 C 1613-30ad, 0.032 0.76 1.78 0 0 0 0 0 0 0 0 i 9A 067 -qC1o,`,'-:,' 50.29 4 k i' ' I .o d 77 0 b 4U" F 19C-19cscp 0.049 0.40 0.32 0 0 0 0 0 0 0 0 F 22-A- jorn' 1.18o Ab8 2M 4,32, 899 b l 55 C, v V' X. P"! 0; J", t 2 7 'jlf! 6 c) AED excursion 185 67, Envelope loss/gain 2868 3242 687 253 12 a) Infiltration 449 180 161 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1200 Subtotal (lines 6 to 13) 3317 3422 848 1518 Less e)dernal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 479 319 439 191 14 Subtotal 3796 1288 1709 15 Ductloads 16% 500/0 605 1 54 16%1 50% 1 8347 Total room load 4402 5594 14931 2556 Air required (dm) 0 259 0 118 Cal cu I ati ons approved by ACCA to m eet al I requi rem ents of M an A J 8th Ed. 4- 2018-Nov-09 15:52.54 Right-Suiteg Unive rsal 2018 18.0.31 RSU 16877 Page 3 IMP PRINT\Lot 197 Barcelona C RHG Office - W.rLp Calc = MJ8 House faces: W A.L Job: Lot 197 Barcelona C RHG Offi 91r wrightsoft, Rig ht-JO Worksheet Date: 07/02/2017 Entire House B - LF/LM One Stop Cooling and Heating Pran: RHG 7225 Sandscove Court,Winter Park, FL32792 Phc)ne: (407) 629-6920 Fax:(407)629-9307 Web: www.OrieStopCooling.com License: CAC032444 1 Room name BED/OFF1 wic 2 Exposed wall 10.0 It 5.0 It 3 Room height 9.3 ft heaV000l 9.3 ft heaV000l 4 Room dimensions 11.0 x 10.0 It 5.0 x 5.0 It 5 Room area 110.0 f12 25.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft?) Load number Btuh4F-9 Btuh/ft2) or perimeter (ft) 13tuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VE G 128 w' 2orn4A5 -0s 0.097 re e, 2.31 4,: 13.09 2.89 2224 0 Z 0 0 0 0 0 0 o 0 0 0 0 0 1, , ,o 0 VL213A-4ocs 0.143 ne 3.40 3.00 93 78 265 234 47 47 158 139 4A5-2om 0.550 ne 13.09 2224 15 0 196 334 0 0 0 0 11 4135-2fm 0.540 ne 12.85 23.69 0 0 0 0 0 0 0 0 B-012 sw 4A5-2orrf-"' 0.097 0.550 Se- se 1 13.09 8 9 1 91 0 0 0 0 0- 111 b o 0 t, 0 0 0 0 o 0 0 0 4B&2fm,': ii, k-, ": :,, 0540 se, 1285 2197 0 0 0 j 0 0 4135-, 'Ir-,-, 1, 11 1 "1 . Di540'`S/6 55 I 0 0 0 I 0 0 b b 0 VL-D 13A-4ocs 0.143 se 3.40 3.00 0 0 0 0 0 0 0 0 1 1DO 0.390 se 9.28 12.54 0 0 0 0 0 0 0 0 Sw, 4M-26m--- 9- 70.Q9 50 311 13.09 2.89 219 b 0 0 0 0 0 0 0 0 0 0 0 4135 -2trrO 0 - w 12.85 3.32 0 0 0 I M-oo 54 1 F 0 0 0 0 13A-4ocs 0.143 sw 8.40 3.00 0 0 0 0 0 0 0 0 4A5-2om 0.550 sw 13.09 22.70 0 0 0 0 0 0 0 0 4135-2fm 0.540 sw 12.85 13.78 0 0 0 0 0- 0, 0`7- 12 8- Osd-,,, 6- 0097", nw 2.31 2.89 0 0 0 0 0 6 o 0 y 0 0L,", -,,",G 4A-2om 550 Aw 13.09 O'k j" 0 0, 0 L--o A, 13A-4ocs 0.143 nw 3.40 3.00 0 0 0 0 0 0 0 0 4A5-2om 0.550 nw 13.09 2224 0 0 0 0 0 0 0 0 4A5-2omd 0.580 nw 13.80 27.82 0 0 0 0 0 0 0 0 R', LOsw . 0 691 2A 7 0 0-, 0 0 0 012 tibib-' , 6390 928 1 .54- Vo 0 b 0 0 0 C 16B-30ad 0.032 0.76 1.78 0 0 0 0 0 0 0 F7-- Z1qA-Qbsc:p , 3 0.295 2 .641, b 6 A AI& 0 O,,: o,,o b 75" 4,,,b F 19C-19csco 0.049 0.40 0.32 0 0 0 0 0 0 0 0 Fl 22A-tpm,,- 1.180 28.08 0.00 10 81 0 25 v, o a'-,44- j 04- V, A101: 25, 71 4 6 c) AED exicursion 8 7 Envelope loss/gain 743 559 2991 132 12 a) Infiltration 140 56 70 28 b) Room ventilaton 0 0 0 0 13 Internal gains: Occupants @ 230 0 01 0 0 Applancias/other 0 0 Subtotal (lines 6 to 13) 883 6151 369 160 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistributon 365 269 0 0 14 Subtotal 1248 885 369 160 15 Ductloads 16% 0 199 438 16%1 50%1 59 79 Total room load 1448 13213 1 41Airrequired (cfm) 01 61-- Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. fjfd- 2018-Nov-09 15:52:54 Rqft-Sute@ Universal 2018 18.0.31 RSU1 6877 Page 4 MP PRINT\Lot 197 Barcelona C RHG Office - W.rLp Calc = MJ8 House faces: W 11 . r wrightsoft, Rig ht-J8 Worksheet Job: Lot 197 Barcelona C RHG Offl Entire House Date: 07/02/2017 Bg LF/LM One Stop Cooling and Heating P an: e RHG 7225 Sandscove Court, Winter Park, FIL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.0neStopCoolirig.com License: CAC032444 1 Room name HALL STR1 2 Exposed wall 0 It 7.5 ft 3 Room height 9.3 ft heat/ccol 9.3 ft heat/ccol 4 Room dimensions 1.0 x 44.0 ft 1.0 x 65.3 ft 5 Room area 44.0 ft2 65.3 W Ty Construction U-value Or HTM Area OF) Load Area (ft2) Load number Btuh/ft2- -F) Btih/ft2) or perimeter (ft) Btuh) or perimeter (ft) Btuh) H eat Cool Gross N/IPS Heat Cool Gross N/P/S Heat Cool 6 VL __X 4A5 -2om 13A-4ocs 550 0.143 w ne 2. 3_1 1,3.09 3.40 280--,, 2224 3.00 0 0, 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0 0 0 4A5-2om 0.550 ne 13.09 22.24 0 0 0 0 0 0 0 0 11 4135-2fm 4A5- 4bt572fm W 0.540 b.'697 0.550 aw ne F so, se, 12.85 2.S1 Zti". '3.09 612.85 ' I 23.69 2.89 9'1 21 -k4'102 0 0 0 0 I I- -, , " 0 0 0 O b 0 0 0 4 0 0 0 A 0 0 0 0 0 0 0 0 0 0, 0 0, 0 0 0 0 Y,1" "o 0 0 Vd 13A-4ocs 0.1431 so 3.4C 3.001 0 0 0 00' 0 0 13A-4ocs 0.143 sw 3.40 3.00 0 0 0 0 70 70 237 209 4A5-2om 0.550 sw 13.09 22.70 0 0 0 0 0 0 0 0 0.540 sw 12.85 13.78 0 0 0 0 0 0 0 12B - 0sw riw 31 289 0 0 0 0 0 0, 0 4A5,26ni-! 0.550' n v q.69 2 .2 4 0 0 0 0 L-P 0 0 13A-4ocs 0.143 nw 3.40 3.00 0 0 0 0 0 0 0 0 4A5-2om 0.550 nw 13.09 2224 0 0 0 0 0 0 0 0 4A5-2omd 0.580 nw 13.80 27.82 0 0_' 0 0 0 0 0 12C-Osw 3,0' 09, 1 2.1'7 1,57- b 0 0' 0 4-11, o o 7' o 11 DO 390-- n 9.28 2.54 0 3i - 0 0 JU *"- , , " 4"o I'! -"-I 'o 0 b 16B-30ao 0.032 0.76 1.78 0 0 0 0 0[ 0 0 19A-0bsclo, 'a W" 2.64 k; 0 o, b n 01 n n nAQ n Ar) n'19 r) n n n n n n 6 c) AED excursion 01 1 11 Envelope loss/gain 0 0 448 198 12 a) Infiltration 0 0 105 42 b) Roorriventilaton 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 0 01 553 1 240 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistributon 0 0 553 240 14 Subtotal 0 0 0 0 15 Duct loads 16%1 50%1 0 0 169/.j 50%. 0 01 Total room load I 1 01 01 0 0 Air required ( cfm) 0 0 1 01 01 Calculations approved by ACCA to meet al I requi rements of Manual J 8th Ed. fj - i 2018-Nov-09 15:52:54 At&_. t Right -Suite@ Universal 2018 18.0.31 RSU1 6877 Page 5 MP PRINT\Lot 197 Barcelona C RHG Office - W.rup Calc = MJ8 House faces: W r wrightsoft, Right-M Worksheet Job: Lot 197 Barcelona C RHG Offi Entire House Date: 07/02/2017 B - LF/LM One Stop Cooling and Heating 2an: RHG 7225 Sandscove Court, Winter Park, FL 32792 PhDne: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopGoolir)g.com License: CAC032444 1 Room name BTH1 LAUN 2 Exposed wall 6.0 ft 3.0 ft 3 Room height 9.3 ft heaVoDol 9.3 ft heat/cool 4 Room dimensions 11.5 x 6.0 ft 1.0 x 86.5 ft 5 Room area 69.0 ft2 86.5 ft' Ty Construction number U-value BtuWOF) Or HTM Btuh/ft2) Area (ft2) or perimeter (ft) Load Btuh) Area 02) or perimeter (ft) Load 13tuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1 2B-Osw -MWR& 4M-26m 0 90 7 ne, 2.31 13.09 2.qg 2 24 0 0 0 0 0 0 0 io b 0 0 0 0 13A-4ocs 0.143 ne 3.40 3.00 56 52 176 155 0 0 a 0 11 4A5-2om 4135-21m 12B`0§`w""' 4M:26m':' 413!: 0.550 0.540 0.550:sel, o 0.540 ne ne I se' 13.09 12.85 L 13.09 Z'A 2 85 12.85 2224 23.69 2.89 21791 12 97 7 2,1-,,',' 0 4 0 b 0 b 0 0 0 0 0 o 0 51 0 0 o b 0 95 0 0 0 0 0 0 0 0 0 0 0 U, 0 0 0 0 0, 0 0 0 0 0 0 b VV" G 13A-4ocs 0.143 se 3.40 3.00 0 0 0 0 0 0 0 0 T-D w 1 1DO 4A5 2 13A-4ocs 0.390 0 097 0.550 6.b ib 0.143 se sN- sw 9.28 13.09 12.85 3.40 12.54 21 91 23 32- 3.00 0 0' S 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0 0 k, -4 b 0 28 0 0 24 0 o 0 81 0 0 0 0 72 4A5-2om 0.550 sw 13.09 22.70 0 0 0 0 0 0 0 0 L--G w 4135-2frn 4A5-2om-- 13A-4ocs 0.540 0.143 sw nw nw nw 12.85 2.31 13.09 3.40 13.78 2.8-9 22 24,,,: 3.00 0 0 0 0 0 0 0 0 0 E 0 0, 0 0 o 0 0 4 0 0 4 0 0 51 0 0 0 0 4A5-2om 0.550 nw 13.09 22.24 0 0 0 0 0 0 0 0 I D, C F 4A5-2omd 12COsw;, 1166' 1613-30ad 1 9A-,"Obs(p, 19C-19csm 0.580 X 6.091 0 3' EQ32 0.295 0.049 nw 13.80 2.:17 9 .28 0.76 f,Z6-- 4,- 0.40 27.82 157 W'12.54 1.78 2.'06 0.321 0 107 i,)"'Ut'o 0 b 0 0 07, 0 0jI001 0 232 4"! 0 0 0 0 0 v '-168 V-.v,, -_0 0 001, 0 21 0 w" 0 0: L, 21 0 01 0 V oi,,l 98 0 0 0 26 7 0 IJO 0 61 c) AED excursion 10 1 Envelope loss/gain 628 408 580 515 12 a) Infiltration 84 34 42 17 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 01 500 Subtotal (lines 6 to 13) 712 442 622 1031 Less external load 0 0 0 0 Less transter 0 0 0 0 Redistribution 0 0 847 623 14 Subtotal 712 442 1469 1655 15 Duct loads 16% 50% 114 219 16% 50% 2 820 Total room load 826 660 1703 2475 Air required (cm) 01 31 114 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2018-Nov-09 15:52:54 RigN-SuiteB Universal 2018 18.0.31 FSUI 6877 Page 6 IMP PRINT\Lot 197 Barcelona C RHG Office - Krup Calc = MJ8 House faces: W rL Job: Lot 197 Barcelona C RHG Offi rF wrightsoft, Right-JO Worksheet Date: 07/02/2017 Entire House Bg LF/LM 2OneStopCoolingandHeatingPan: RHG 7225 Sandscove Court, Winter Park, FL 32792 Phore: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCoolir)g.com License: CAC032444 1 Room name MBED MTOI 2 E)posedvQll 46.0 ft 3.5 ft 3 Room height 9.0 It heat/000l 9.0 It heat/cool 4 Roomclimensions 1.0 x 320.3 ft 3.5 x 5.5 ft 5 Room area 320.3 It' 19.3 ft' Ty Construdon U-value or HTM Area (ft2) Load Area 01) Load number Btuh/11 09 Btuh/ft2) or perimeter (ft) Btuh) or perimeter (ft) Btuh) H eat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1"2'-B---0sw 4A5 26fti 0'.097 6e ne 31' 8'9 224 149 36 119 0--- 274 393 342 1 -,--667 0 0 U--- 0 0 o 13A-4ocs 0.143 ne 3.40 3.00 0 0 0 0 0 0 0 0 G 4A5-2om 0.550 ne 13.09 2224 0 0 0 0 0 0 0 0 11 G 4135-2frn m BF,2fm", 0.540 0.097 0.550 ow, 0.540 ne se se se 12.85 P i 13.09 12.85 2.85 23.69 289 21.91 21.97 22.72 0 h' ;'o 0 6 0 0 0 0 0 0 am 0 0 0 0 0 0 0 0 J' 0 Fo o 0 g 0 V1w 0 0 E.o 0 o 0 0 0, q 1 0 VL-D 13A-4ocs 0.143 se 3.40 3.00 0 0 0 0 0 0 0 0 G, VL213A-4ocs 1 1DO 4A&2- Vwi"" 4R572ffn-, 0.390 0097 0'550 V '0.540 0.143 se sk svv 9.28 31- 37'09 1 2.85 3.40 12.54 21.9 23.32 3.00 0 l 17 0-0 0 0 0 117 0 N"""o 0 0 270 o 0 0 3W 0 0 0 0 0 v-ojW'M".4v' 0 0 0 4,0TV 0 0 0 0 0 0 J:p 1, -, 0z 0 4A5-2om 0.550 sw 13.09 22.70 0 0 0 0 0 0 0 0 V G 4B5-2frn 1 213-0s'-w` AA5,2om, 0.540 0097 O' 50 sw nw nw 12.85 2.31 I ):-s A 3 09 13.78 892, 22241 0 T 149 3b 0 1 --1 9 b 0 04 393 0 342 667 0 32 A,, - 0 0 2"- 0" 0 72 1 o 0 1 0 13A-4ocs E1431 nw 3 40 3.00 01 0 0, 0 0 0 0 0 4A5-2om 0.5501 nw 1 13.09 22.24 0 0 0 0 0 0 4A5-2omd 0.5801 nw 1 13.80 27.1 0 0 0 0 0 0 0.40 61 c) AED excursion 1 150 1 1 -6 Envelope loss/gain 2163 3023 87 119 12 a) Infiltraton 625 250 481 19 b) Room ventlation 0 0 0 0 13 Internal gains: Oocupants @ 230 2 460 0 01Appliance,,Vother 0 0 Subtotal (lines 6 to 13) 1 2788 3734 1351 138 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistributfon 0 0 0 14 Subtotal 2788 3734 135 138 15 Ductloads 16% 50% 444 1850 16% 501/6 22 68 Total room load 3233 5584 156 207 Air required (cfrn) 0 258 0 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Nov-09 15:52:54 1 - 1. Right-Sute@ Universal 2018 18.0.31 RSU1 6877 Page 7 4cc-pl IMP PRINT\Lot 197 Barcelona C RHG Office - W.rup Calc = MJ8 House faces: W d 1. Job: Lot 197 Barcelona C RHG Offi rF wrightsoft, Right-M Worksheet Date: 07/02/2017 Entire House - LF/LM One Stop Cooling and Heating BP n: RHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC032444 I Room name MBTH IMIC 2 Exposed wall 21.5 It 8.0 ft 3 Room height 9.0 It heaVcool 9.0 It heaVoDol 4 Room dimensions 1.0 x 136.0 It 10.5 x 8.0 ft 5 Room area 136.0 1112 84.0 ft2 Ty Construction U-value Or HTM Area (ft) Load Area (ft2) Load number Btuht--F) Btuh/ft2) or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 213-,0swI, 4A5 2om 0.097 0.550 ne ne 2.31 13.0 9 2 89 22724 O 0 0 4v', b 0 0 0 72 0 2 0 1 6 O Ij 2b8 0 13A-4ocs 0.143 ne 3.40 3.00 0 0 0 0 0 0 0 0 4A5-2om 0.550 ne 13.09 22.24 0 0 0 0 0 0 0 0 11 4135-2frn 0.540 ne 12.85 23.69 0 0 0 0 0 0 0 0 V)w, 1213-6-""-, 4,W2om A,",O.097`11,1 sel 0.550 0.540 0. 540 se', se se- 13.09 12 85 1 2.85 7289 21. 91 2 1'97 22.72 0zMr- ' ' ;t ' 0"' 0 0 0 0- 0 0 0 0 0 0 0"'' 0 0 0 0 O 0 0 b 0 0 0 0 0 0 C- J. I-D 13A-4o cs 0.143 se 3.40 3.00 0 0 0 0 0 0 0 0 L:2 1 1 DO 4A5'2 AB om 13A-4ocs 0.390 0,097 0.550 Q.54O,,:,,sw 0.143 se 9N sw 9.28 2 3i 13:09 2.85 3.40 12.54 2.6b 1.91 23.3 2 3.00 0 1 04i" 15 it" 0 0 0 T''89 1 0 0 0 204 91 6 0 0 0 255 7329 0 0 0 0 0 0 0 0 U 0 0 0 0 0 b 0 0 0 4A5-2om 0.550 sw 13.09 22.70 0 0 0 0 0 0 0 0 Vw 4135-2trn 12B -'O-s-w 4M 2om--,,,," 0.540 10.097 sw rw" nw' 12.85 23 1 3.09 13.78 2.89 0 Y 4'-!i'go' 0 0 so 0 0 20 8 0 0 t,-260 0 0 0 0 0 0 0 O 0 0 13A-4ocs 0.143 nw 3.40 3.00 0 0 0 0 0 0 0 0 4A5-2om 0.550 nw 13.09 2224 0 0 0 0 0 0 0 0 L -"---'D C 4A5-2omd 12C-Osw7, 1 DO 1613-30ad 1`9A-'Obscp"'- 0.580 W" 0.091 0.390 0.032 295 nw n 13.80 217 0.76 27.82 S 12.54 1.78 e-2.06 0 TO A' 136 0 0 0 0 136 0 0 104 0 0 O 0 242 0 0 0 z4'', 0 84 0 0 yb 84 0 0 64 A 0 0 150 F Ff ------ 19C-19= 2 A- Mtp 0.049 180 0.40 28.08 0.32 VDW-' 0 0 0 0 0 c: 0 0 0 0 0 0 2% A' 77,77a nt R", 7' y X M' :j q- ki 2n'; M, 0 6 6 c) AED excursion 65 17 Envelope loss/gain 712 1151 2301 340 12 a) Infiltration 292 117 109 44 b) Room ventilation 0 0 0 0. 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 6 Subtotal (lines 6 to 13) 1004 1268 339 384 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistributon 187 317 0 0 14 Subtotal 1191 1585 339 384 Ductloads 16% 50% 190 786 16% 50% 54 1901 Total room load 13811 23711 393 574 Air required (cfm) 0 110 0 27 Calculations approved byACCAto meetall requirements of Manual J 8th Ed. ri- 2018-Nov-09 15:52:54 Right-Suite(D Uriversal 2018 18.0.31 RSU1 6877 Page 8 MP PRINT\Lot 197 Barcelona C RHG Office - Krup Calc= MJ8 House faces: W dj- wrightsoft, Right-JO WorksheetrF Job: Lot 197 Barcelona C RHIG Offi Entire House Date: 07/02/2017 BP LF/LM One Stop Cooling and Heating a n: RHG 1 Room name BED3 2 Exposed wall ft 27.0 ft 3 Room height 9.0 It heaV000l 9.0 it heat/cool 4 Room dimensions 3.5 x 5.5 ft 1.0 x 139.3 ft 5 Room area 19.3 it' 139.3 ft' Ty Con&uction U-value Or HTM Area (ft2) Load Area (ft) Load number Btuh/ft OF) Btuh4l2) or perimeter (ft) 13tuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V 4A5-2om,' 0".09'7 ne 31 2.89 0 0 b i'2"6 1 6, 2 291 364 G 0.550 ne,, 1 M 9 2224 0 0 V -0 w 0 0 01 13A-4ocs 0.143 ne 3.40 3.00 0 0 0 0 0 0 0 0 T-:GG 4A5-2om 0.550 ne 13.09 22.24 0 0 0 0 0 0 0 0 11 4135-2fm 0.540 ne 12.85 23.69 0 0 0 0 0 0 0 0 1213-0sw,,, 4A5726m,,, 01.097 0 5 5b 7 se 2.S! 13'.0'9 2M 21'.9'l' 1 0 0 0- 0 0 0 d-o 0 99 15 1 84 1§4 1, 96 242 J 329G G 4135-2fm' 0.540 12.85 21.97 0 0 01" 0 0 4135 -2frn U W, 12.85, 22.72 A 0 0 71 0 0, I "', 0 0, Q t-D 3A-4ocs111DO 0.143 se 3.40 3.00 0 0 0 0 0 0 0 0 0.390 se 928 12.54 0 0 0 0 0 0 0 0 G 4A 097 0.550 sw svv- 4 31 3.09 21.91 0 0 Cl:,,"-,:,o 0 0 0 b i8 b 18 0 0 2 0 G 4 b540 S' w 12.85 23.32 0 0 0 0 Co o 13A-4ocs 0.143 sw 3.40 3.00 0 0 0 0 0 0 0 0 4A5-2om 0.550 sw 13.09 22.70 0 0 0 0 0 0 0 0 G 4135-2frn 0.540 sw 12.85 13.78 0 0 0 0 0 0 0 0 A 213-0s v O 07 n\v 7"R`-Z 89 0 h, b 0 0 0 0 b L, -"G 4A5726m,,,,,, f'O.550 nw 3:09 2224 0 1k:o'0 0 0 0 13A-4ocs 0.143 nw 3.40 3.00 0 0 0 0 0 0 0 0 T-::G 4A5-2om 0.550 nw 13.09 2224 0 0 0 0 0 0 0 0 G 4A5-2omd 0.580 nw 13.80 27.82 0 0 0 0 0 0 P 12C -Osw,: 0091 2-17 18 1'57 6, 0 O 0 0 o 0 9',4 ", 0 0 L42b-, 111610,-Icl- J 7" 10.390 9.2 12.54 M 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.76 1.78 19 19 15 34 139 69 106 248 ALL' Sep 0.g 264 2.66 0 0 b 0 W, b F 19C-19c= 0.049 0.40 0 0 0 0 85 85 34 27 28.08 0.32 6 W0 Q 0 N, o b 0 7F 7 iF 19 7, K, iQ U, H p-, P W R ri,7 k MMIL 0 6 c) AED excursion 32 Envelope loss/gain 15 33 863 1293 12 a) Infiltration 0 0 367 147 b) Room ventilation 0 0 0. 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 15 33 1230 1670 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 15 33 11 14 Subtotal 0 0 123 1681 15 Ductloads 16%1 50%1 0 0 16%1 50% 197 833 Total room load 0 0 1432 2514 Air required (cfm) 01 0 0 11 6 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Nov-09 15:52:54 Right-SuitegUnversal 2018 18.0.31 RSU1 6877 Page 9 MP PRINT\Lot 197 Barcelona C RHG Office - Krup Cale = MJ8 House faces: W J- Job: Lot 197 Barcelona C RHG Offi 1+ wrightsoft, Right-JO Worksheet Date: 07/02/2017EntireHouse M: LF/LM 2OneStopCoolingandHeatingPan: RHG 7225 Sandscove Court, Wirter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.0neStopCooling.com License: CAC032444 1 Room name BTH3 T013 2 Exposed wall 5.0 ft 15.5 ft 3 Room height 9.0 ft heaVoDol 9.0 It heal/cool 4 Room dimensions 5.5 x 5.5 ft 6.0 x 7.5 ft 5 Room area 30.3 ft2 45.0 ft2 Ty Construction U-value Or HTM Area 011) Load Area (ft2) Load number Btuh4V-0F) Btuh/ft2) or perimeter (ft) Btuh) or perimeter (ft) Btih) H eat Cool Gross N/P/S Heat Cool Gross N/F/S Heat Cool 6 V G I 231 2 -89 i10 0 0 0`0 N,18 J8 82 4A5 -2 0.550 ne_ 1309 2 224 0 0 0 4 b2 D 0 13A-4ocs 0.143 ne 3.40 3.00 0 0 0 0 0 0 0 0 1 4A5-2om 0.550 ne 13.09 2224 0 0 0 0 0 0 0 0 1 0.540 ne 12.85 23.69 0 0 0 0- 0 0 0 04!35-2fm__ 1 4A5- 26 0 097 0.550 6' s6;, 2.31", 3b9 99 k"_ 21'.91 45 0 j: 9 04 90', 0 113 0 54 48 j, 0 111- io 39 0 4135 -2fm se, 12.85 21;97 0 0 b 0 0 0 0 413E 21`r 0.!* e, 12.85 22.72- 6 1 1 77 136 T7 1 36 Y-D 13A-4ocs 0.143 se 3.40 3.00 0 0 0 0 0 0 0 0 1 1DO 0.390 se 9.28 12.54 0 0 0 0 0 0 0 0 2B- A45-2-- b.097 0 550 Sv sw 13.0,1 2 89 1'91 0 0 0 b pi' 0 68 0 N 18 0 105 0 pi sWi% ii, A 'l 2. _5 432 r,, O 0_ b o x -'"'o 0 13A-4ocs 0.143 sw 3.40 3.00 0 0 0 0 0 0 0 0 4A5-2om 0.550 sw 13.09 22.70 0 0 0 0 0 0 0 0 0.540 sw 12.85 13.78 0 0 0 0 0 0 0 04_B5-2frn T ..... .. 1260 31 2 89 2 4 0 0 0 0 b 0 01 4M-26mr,",-1 0.5501 nw, 09 0, 0 b 0 13A-4ocs 0.143 nw 3.40 3.00 0 0 0 0 0 0 0 0 4A5-2om 0.550 nw 13.09 22.24 0 0 0 0 0 0 0 0 4A5-2omd 0.580 nw 13.80 27.82 0 0 0 0 0 0 0 0 0.091 217 9 - 157 0 b 0 b 0 A' 0, Pt"W 0 lbo, IN,—: 0.390 n 12 .54 0 a 0 0 4 0 0 o Af '0 0 C 16B-30ad 0.032 0.76 1.78 30 30 23 54 45 45 34 80 r, 1 5A-'Obs, 0. 295 2.06 1 T 'r, f ,, 0 T o 0 X'_ :,,'-_ 6 Ab F 19C-119pscp 0.049 0.40 0.32 30 30 12 10 45 45 18 14 1180 2 .088 bbb 0 N M 7, 4 V t V, 4 V" A: - A' P, U, kz5 z i 6 c) AED excur§on 47 31 Envelope loss/gain 202 359 438 647 12 a) Infiltration 68 27 211 84 b) Room ventilation 0 0 0. 0 13 Internal gains: Oowpants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 270 386 648 732 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 270 386 648 732 15 Ductloads 16%1 50%1 43 191 16%] 50%1 103 363 Total room load I 3131 578 752 1094 Air required (cm) 0 27 01 51_ Calculations approved byACCAto Meetall requirements of Manual J 8th Ed. F 1- i 2018-Nov-09 15.52:54 1: 1.1-1-- Rigli-SuiteOUNversal 2018 18.0.31 RSU1 6877 Page 10 40C_-K MP PRINTLot 197 Barcelona C RHG Offire -W.rLp CaIc=W8 Housefaces:W j . Job: Lot 197 Barcelona C RHG Offi Fjd- wrightsoft, Rig ht-J@ Worksheet Date: 07/02/2017 Entire House Bg: LF/LM One Stop Cooling and Heating P an: RHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wvvw.OrieStopCooling.com License: CAC032444 1 Room name STR2 BED 2 2 3 Exposed wall Room height 7.0 ft 9.0 ft heat/cool 19.5 It 9.0 ft heat/oDol 4 5 Room dimensions Room area 13.5 x 7.0 ft 94.5 ft' 1.0 x 144.0 It 144.0 ft2 Ty Construcion number U-value Btuh/ft2--F) Or HTM Btuh/ft2) Area (ft2) or perimeter (ft) Load Btuh) Area (ft2) or perimeter (ft) Load Btuh) H eat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 12 0sw, 4A, 13A-4ocs 4A5-2om 4B5-2fm B' 12 -05w 4135-2frn - 1: . . . .. ...... 413572fm.' 13A-40cs 11DO A5:2 " fk- 4 qm 4B5-2fni - 3A-4ocs 4A5-2om 4B5-2fm 112 13716., 4A5 -2om- 13A-4ocs 4A5-2om 4AS-Pornd 0 097 05 50 0.143 0.550 0.540 A097 0.550 I", , x' I0540 0.143 0.390 0097 b.55o 0.540 0. 143 0.550 0.540 0. 00 0.5501 0.143 500.5 0 0.580 nel ne ne ne ne L §e se, I'll", se, se se se sws, j3W sw sw 9N nw nw 311 13.09 3.40 13.09 12.85 2 31 13. 09 I ''1", I 1 285 2.85 3.40 9.28 2.3f 13.09 1285 3.40 13.09 12.85 31 13.09 340 13:09 13.80 2.89 2224 3.00 2224 23.69 289 2191 6 2272 3.00 12.54 21-91 3.00 22.70 13.78 2 89 2224 3.00 2 224 27.0' 0 A" 0 0 0 0 0 0 0 0 0 63 011 0 0 0 0 0 0 0 0 1 -.1-11- 0 0 0 0 0 0 C 6 0' 0 0 0 46 1 0 0 0 0 0 0 0 0 5- ' 1 11 0 01 0 0 0 0 0 0 0 0 193 0 0 0 o 1 0R' 0 0 0 10'' I - 0 0 0 Z" 0 0 0 0 0 0 0 0 6! 'o 0 0 0 11 0 0 0 0 0 72 y' 0 0 0 0 164 sJ 0 0 0 0 b 0 0 11 1 1 0 0 0 0 68 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1157 0 51 0 0 0 7`r'N!'7'04 0 0 0 4 0 0 0 0 0 o 0 0 0 0 96 0 T`88 0 0 5 o 0 0 0 0 4"," 0 0 0 0 V G Y-D VL 1 T 61 c) AED excursion 1 105 1 1 14 Envelope loss/gain 376 761 750 1163 12 a) Infiltraton 95 38 265 106 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 471 7991 1015 1499 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 471 799 152 259 14 Subtotal 0 0 1168 1758 15 Ductloads 16% 50./. 0 0 16%1 50-/.j Idol 871 Total room load 0 0 1354 2629 Air required (cfm) of 21- 0 121 Calculations approved byACCAto meot all requirements of Manual J 8th Ed. Fi- 2018-Nov-09 15:52:54 Q Rigft-Suiteg Universal 2018 18.0.31 RSU1 6877 Page 11Z5KAC MP PRINT\Lot 197 Barcelona C RHG Office - W.rL;) Calc = MJ8 House faces: W wrightsofte Duct System Summary Job: Lot 197 Barcelona C RHG Date: 07/02/2017 Entire House By. LF/LM One Stop Cooling and Heating Plan: RHG 7225 Sandscove court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: www.0neStopCooling.com License: CAC032444 V 41, A5 R, ME &V I Vtv;j MM For: Park Square Homes FL External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H20 0.16 in H20 0.34 in H20 0.170 /0.170 in H20 0.120 i n/1 00ft 0 cfm 284 Cooling 0.50 in H20 0.16 in H20 0.34 in H20 0.170 /0.170 in H20 0.120 i n/1 00ft 1567 cfm Name Design Btuh) Htg cfm) Clg cfm) Design FIR Diam in) HxW in) Duct Matl Actual! Ln (ft) Ftg.Eqv Ln (ft) Trunk BED2 c 2629 0 121 0.170 7.0 Ox 0 VlFx 29.9 170.0 st6 BED/OFFI c 1323 0 61 0.168 6.0 Ox 0 V1 Fx 27.4 175.0 st2 BED3 c 2514 0 116 0.188 6.0 Ox 0 VlFx 30.7 150.0 st4 BTH1 C 660 0 31 0.185 4.0 Ox 0 V1 Fx 18.9 165.0 st2 BTH3 c 578 0 27 0.178 4.0 Ox 0 V1 Fx 20.9 170.0 st6 DIN C 3278 0 152 0.120 7.0 Ox 0 V1 Fx 73.8 210-.0 st3 GATH c 2797 0 129 0.135 7.0 Ox 0 VlFx 51.8 200.0 st3 GATH-A c 2797 0 129 0.141 7.0 Ox 0 Vl Fx 46.3 195.0 st3 KIT c 2556 0 118 0.120 7.0 Ox 0 M Fx 72.8 210.0 st3 LAUN c 2475 0 114 0.185 6.0 Ox 0 AFx 24.0 160.0 st2 LOFF c 2223 0 103 0.168 6.0 Ox 0 AFx 42.0 160.0 st5 MBED-A c 5584 0 258 0.170 9.0 Ox 0 VlFx 35.5 165.0 st5 MBTH c 2371 0 110 0.172 6.0 Ox 0 M Fx 33.0 165.0 st5 MToI c 207 0 10 0.182 4.0 Ox 0 A Fx 31.4 155.0 st5 MWIC C 574 0 27 0.170 4.0 Ox 0 VlFx 34.9 165.0 st5 T013 c 1094 0 51 0.177 4.0 Ox 0 A Fx 22.4 170.0 st6 WIC C 240 1 0 1 11 0.182 4.0 Ox 0 11 Fx 21.5 165.0 st2 wrightsoft, Rigli-SLiteO Uriversal 2018 18.0.31 RSU1 6877 AC(>, ...MP PRINT\Lot 197 Barcelona C RHG Offire - W.rLp Calc = MJ8 House faces: W 2018-Nov-09 15:52:55 Page 1 VW, - - -- knnKLRetaiI, Pj b eIWOO Name Trunk Type Htg Cfm) CIg Cfm) Design FR Veloc fpm) Diarn in) HxW in) Duct Material Trunk st2 PeakAVF 0 745 0.120 697 14.0 0 x 0 VinIFIx sti st4 PeakAVF 0 821 0.168 768 14.0 0 x 0 VinIFIx sti st5 PeakAVF 0 506 0.168 645 12.0 0 x 0 VinIFIx st4 sti PeakAVF 0 1567 0.120 887 18.0 0 x 0 VinIFIx st3 PeakAVF 0 528 0.120 672 12.0 0 x 0 VinIFlx st2 st6 PeakAVF 0 199 0.170 364 10.0 0 x 0 VinIFIx st4 I ! Ii, I 1 11 , I I '' ''M I, LFTY-ii6 1 el, ii 11MANWHANWIN 1 R-AW= Name Grille Size (in) Htg cfrn) Cig cfm) TEL ft) Design FR Veloc fpm) Diam in) HxW in) Stud/Joist Opening (in) Duct Mal Trunk rbl Ox 0 0 1567 0 0 0 0 Ox 0 AFx wrightsoft, 2018-Nov-09 15:52:55 Righ-Suite(9 Unversal 2018 18.0.31 RSU1 6877 Page 2 ACCA MP PRINTIot 197 Barcelona C RHG Office - W.rLp Calc = MA HoLrse faces: W Static Pressure and Friction Rate Job: Lot 197 Barcelona C RHG wrightsoft, Date: 07/02/2017 Entire House By. LF/LM One Stop Cooling and Heating Plan: RHG 7225 Sardsoove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: www.OreStopCoolirg.com Licerse: CAC032444 For: Park Square Homes FL whiVU4 Heating Cooling in H20) in H20) External static pressure 0.50 0.50 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 0.34 Supply Return ft) ft) Measured length of run -out 29 0 Measured length of trunk 45 0 Equivalent length of fittings 210 0 Total length 284 0 Total effective length 284 Supply Ducts Return Ducts N'RY "'15 -"FXA -2 1- Heating i n/1 00ft) 0.120 OK 0.120 OK Cooling i n/1 00ft) 0.120 OK 0.120 OK ww4j'g. w'. 0 n Supply 4X=35, 11 A=20, 11 G=5, 11 G=5, 11 G=5, 11 G=5, 11 A=20, 11 J=1 5, 11 G=5, 11 G=5, 11 G=5, 11 M =20, USR1 65: Total EL=21 0 Return TotalEL=O wrightsoft, 2018-Nov-09 15:52:55 Righ-Suite@Ur versal20l8l8.0.31RSU16877 Page 1 ACACk MP PRINTIot 197 Barcelona C RHG Office - W.rLp Calc = MA HoLze faoes: W D IOX8 152 cfm EF1 = 50 CFM Fan EF2 = 80 CFM Fan EF3 = 110 CFM Fan EFL1 = 50 CFM Fan EFL2 = 80 CFM Fan EFL3 110 CFM Fan VTR Vent to Roof VFW = Vent to Wall DV = Dryer Venf RV = Range Vent Lineset Chase Condensate — Thermostat 18/8 SRB = Small Reduction Box LRB = Large Reduction Box FBB = Field Built Box Job M Barcelona C RHG Office Performed by LF/LM for: Park Square Homes FIL 7" Level I FBB3 7' 1OX10-2 NY19 cfm 118, GATH fm KA 7 "11OX8IT 129 cfm 1OX10 1OX10-2 91, 1OX6 1OX10 STRI 61 cfm I BED/ I 6' 12" 8X4 11 cfm FOY 1OX6 Sup Riser 114 cfrn 4 14 6" 4" L DV VTR LAUN 11 cfrn 8X4 EF1 VrR Lai A/C-1: 4 ' 0 TON 16.0 SEER H.P. GARAGE One Stop Cooling and Heating 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 www.OneStopCooling.com Scale: 1 :94 Page 1 Right -Suite@ Universal 2018 18.0.31 RSU21856 2018-Nov-01 M05:49 Level 2 EF1 VTR OF 91, 8X4 MTOI 4" SRB2 10 drin EF1 VTR l0X6 16 6 lloctl MBTH 14 12" STR2 12x 12 12x 12 121 cftn 12'. IOX8 7" LRB1 j Zone Damper 1 - 14' p Zone Damper2 -14" BED 2 10, 14 "' 18" Bypass Damper- 12" EF1 = 50 CFM Fan EF2 = 80 CFM Fan EF3 = 110 CFM Fan EFLI = 50 CFM Fan EFL2 = 80 CFM Fan EFI-3 110 CFM Fan VTR Vent to Roof VTW = Vent to Wall DV = Dryer Vent RV = Range Vent Lineset Chase Condensate — Thermostat 18/8 SRB = Small Reduction Box LRB = Large Reduction Box FBB = Field Built Box Job #: Barcelona C RHG Office Performed by LFA-M for: Park Square Homes FIL MBED 12XI2-1 258 ctrin 4" 8X4 27 cfm MWIC 16x 16 l0X6 6 103 ctn LOFT Sup Riser 14" 6" I IS"'B —\ 11OX6 4 14"lox,o ' 16 cfm17lox10 EFI VTR 3 15E 7 chn IE BT' OX18 X 27 cfrn 8X4 51 CfM BED3 T013 One Stop Cooling and Heating 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 www.OneStopCooling.com Scale: 1: 94 Page 2 Right -Suite@ Universal 2018 18.0.31 RSU21856 2018-Nov-01 09:05:49 4y'tl& L om- Ize I RECORD COPY G , ri-fl-11, 5 NNo CDPD J k Ucopm copy Filename: PARK SQ BARCELONA.rrr Lighting and Small Appliance/Laundry Circuits Floor Area SmAppNo LaundNo Line Neutral 2392 2 1 Lighting Summary Standard 6,037 6,037 Optional 11,676 6,037 5-2- Ranges & Ovens BU/4,0RangeNo. No? Nameplate Line Neutral z 8000 2 0 0 3 0 0 Range/,Oven Summary Standard 6,400 4,480 Optional 8,000 4,480 7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Dryers Dryer No. No? Nameplate Line Neutral 1 1 5000 0 3 0 Dryer Summary Standard 5,000 3,500 Optional 5,000 3,500 Heating and Cooling: Actual Number = I Name M? Ph No Amps Volts VA HP Line Neutril 1 M 1 1 27.0 240 6,480 0 M 1 1 2.0 240 480 0 M 1 1 5.0 240 1,200 10 1 1 1 27 240 1 6,480 0 Reat/Cool Summary Standard 14,640 0 Optional 14,640 0 Fixed Appliances: Actual Number = 6 Name M? Ph No Amps Volts VA HP L ine Neutral DISP 1 1 120 600 600 600 DISH 1 1 120 1200 1,200 1,200 MICRO 1 1 120 1200 1,200 1,200 WATER HEATER 1 1 18.5 240 4,440 0 OPT POOL 1 1 10 240 2,400 0 OPT POOL HEAT 1 1 31 240 7,440 0 Fixed Appliance Summar y Standard 12,960 2,250 Other'Appliances: Actual Number 0 Optional 17,280 2,250 Name M? Ph No .-Amps Volts VA HP Line Neutral Other Appliance Summary Standard 0 0 Optional 0 0 25-0. of Max Motor: Line is Std Only; Neutral for Both maximum Phase Amps Volts 27 240 Heat/Cool Phase Amps Volts 27 240 Fixed Appl. Phase Amps Volts 0 Other Appl. Phase Amps Volts 0 Max Motor Summary Standard only 1,620 0 SUMMARY Standard Line Neutral Total Total 46,657 16,267 Maximum Amperage 194 68 Service Voltage = 240 Service Phase Optional Line Neutral Total Total 37,422 16,267 maximum Amperage 156 68 Service Voltage = 240 Service Phase = I DESCRIPTION -AS FURNISHED: Lot 197, WYNDHAM PRESERVE, as recorded in Plot Book 81, Pages 93 through 102 of the Public Records of Seminole County, Florida. PLOT PLAN FORICERTIFIED TO: Park Square Enterprises, LLC (a Delaware rC'Urp;:ra tip'n),;- - v, Winderweedle, Haines, Ward & Woodman, FfA', Attorneys Insurance Fund; Bank of America DEC 1 2 LOT 203 LOT 202 LOT 201 S 00016'57" E X 60. 00' Ok to construct single family home LOT 197 with setbacks and impervious area 24.50' 24.80' shown on plan. Awce 10A4 -C z- 3 Artje.. ittjH, 17, (01t i5lz' 15.00' - 15.00' 14. 0' LANAI 16.0' 15.00' PROPOSED RESIDENCE Q02392-BARCELONA-C 2 CAR GARAGE RIGHT LOT 198 LOT 196 LO Q) z), COV'D. OD ENTRY ECORD 15.00' 8.0' Copj,. 3.0'x4.0'- 11.00' AC 15.00' 22.0' 1 15.00' 16' WAL DRIVE 25.20 25.20 10' UTIL ESMT. 5' CONC, WALK S 00016'57 =E 60. 00' --- 17, --n SETBACKS AS FURNISHED I FRONT 25'(-) NIGHT HERON DRIVE REAR 20' SIDE 5' (40' LOT) 50' PRIVATE RIW) 7.5' (60' LOT) 10' (75' LOT) SIDE STREET 25' (60' & 75' LOT) 15' (40' LOT) 25' FRONT SETBACK CAN. BE REDUCED TO 20' ON CERTAIN LOTS. NO MORE THAN PLOT PLAN ONLY 2) IN SUCCESSION AT 20' AND A MINIMUM PLOT PLAN AREA CALCULATIONS NOT A SURVEY OF (2) IN SUCCESSION AT 25' TOTAL LOT AREA 6,900' SQUARE FEET PROPOSED = FINSHED SPOT GRADE ELEVATIONS FLATWORK ONIOFF LOT = TOTAL ± SQUARE FEET FLATWORK PER DRAINAGE PLANS DRIVE 403111 O= 513 ± SQUARE FEET FOUNOATIONIPAD 1,641 ± SQUARE FEET PROPOSED DRAINAGE FLOW WALKS 691300= 369 ± -SQUARE FEET REAR PATIO 117 ± SQUARE FEET FRONT PORCH DECK 99 SQUARE FEETLOTGRADINGTYPEA41/ SOD 4,5601250 = 4,8 10 ± SQUARE FEET POOL DECK NIA ± SQUARE FEET PROPOSED F.F. PER PLANS = 23, 1' NOTE: FRONT SIDEWALK AND STREET LOCATION TAKEN FROM ILANS PROVIDED BY CLIENT NOT FIELD VERnEO CRUSENAIEEER -SCOTT ASSOC, INC - LAND SURHEMRS LEGEND - LEGEND - 5400 E. COLONIAL OR. ORLANDO, FL. 32807 (407)-277-32,32 FAX (407)-658-1436PPLATPJ_ POINT ON LINED NOTES: F FIELD TYP. TYP ICAL TP IRO" PIPE PR.0 POINT OF REVERSE CURVATURE POINT OF COMMIR. IRON ROO P.C.C. )UND CURVATURE 1. THE UNDERSIGNED DOES HEREBY CERTIFY THAT THIS, SURVEY MEETS THE STANDARDS OF PRAC77CE SET FORTH BY THE FLORIDA BOARD OF C.H. NCRET E MONUMENT RAD. RADIAL PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER 5J-17 FLORIDA AOX41NISTRATW CODE PURSUANT TO SEC77ON 472,027, FLORIDA STATUES SE T TA 1 '/2' IR 1111 MR. NON -RADIAL , 2. UNLESS EMBOSSED WITH SURVEYOR'S SIGNATURE AND ORIGINAL RAISED SEAL, THIS SURVEY MAP OR COPIES ARE NOT VALID. REC. RECOVERED W.P. WITNESS POINT J. THIS SURVEY WAS PREPARED FROM 7TILEINFORM471ON FURNISHED TO THE SURVEYOR. THERE MAY BE OTHER RESTRICTIONS P.O.B. PUINTT OF 'INNING CALC CALCULATEDEEC OR EASEMENTS THAT AFFECT THIS PROPERTY. POC PO 14, QF,CCMHENCEMENT P.RA PERMANENT REFERENCE MONUMENT 4. NO UNDERGROUND IMPROVEMENTS RAVE BEEN LOCATED UNLESS OTHERWISE SHOWN. E CENT RLI,E FF ' FINISHED FLOOR ELEVATION NLD NAIL " D SK BS.L. BUILDING SETBACK LINE 5 ' THIS SURVEY IS PREPARED FOR THE SOLE BENEFIT OF THOSE CERTIFIED TO AND SHOULD NOT BE RELIED UPON BY AMY OTHER ENTITY. R/W RIGHT-OF-WAY BA BENCHKA K 6 DIMENSIONS SHOWN FOR THE LOCATION OF IMPROVEMENTS HEREON SHOULD NOT BE USED TO RECONSTRUCT BOUNDARY LINES. ESMT. EASE MENT Bi BASE BEARING 7' BEARINGS, ARE 134,CO ASSUAIEP,DATUM AND ON THE LINE SHOWN AS BASE BEARING (B.B.) IRAIN DRAINAGE B. ELEVATIONS, IF, AN, ARE EkSED 614 NATIONAL GEODETIC VERTICAL DATUM OF 1929, UNLESS OTHERWISE NOTED. SHCe UTIL. UTILITY CL.FC. CHAIN LINK F ENCE WDFC. VODD FENCE T 9. CERT)RCC E, OF AUTHORIZATION N.. 45 6. C/B CONCRETE BLOCK POINT OF CURVATURE I T_ SCALE I- I" = 20'_ RAWI By.. PC, P.T. PO N I OF TANGENCY DESC. DESCRIPT I ON CERTIFIED 6": DA TE 0, ROER Nb. R RADIU S L AR C LENGTH PLOT PLAN 11-05-2018 7,360-18 D DELTA C CHORD C.B. CHORD BEARING NORTH THIS BUILDING\PROPERTY DOES NOT UE WITHIN THE ESTABLISHED 100 YEAR FLOOD PLANE AS PER 'FIRM" TOM k,,GRUSE HFYER, R.L.'s. JAMES W, SCOTT RLS #4801 ZONE "XI MAP j 12117CO090 F (09-28-07) RECORD COPY RE: P2392ACT Park Sq/Barcelona-A or C TRAY MiTek USA, Inc. 6904 Parke East Blvd. Tampa, FL 33610-4115 Site Information: Customer PARK SQUARE HMS Project Name: P2392ACT Lot/Block: 197 Model: BARCELONA 2392-AC/TRAY Address: 3951 NIGHT HERON DR. Subdivision: WYNDHAM PRESERVE 40' City: SANFORD State: FLORIDA 1. 8 - 4 5 2 General Truss Engineering Criteria & esign Loads (individual Truss Design Drawings Show Special Loading Conditions): I L 1'06DesignCode: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE7-10 A Wind Sneed: 140 mph JVF0P Roof Load: 40.0 psf 'D Floor Load: 55.0 psf This package includes 72 individual, dat e s li) _S1T Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby c I am the Truss Design Engineer and this index sheet conforms to 61 G 15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date No. Seal# Truss Name Date 1 T13452380 al 3/9/18 26 T13452405 d1t 3/9/18 2 T13452381 a2 3/9/18 27 T13452406 d2 3/9/18 3 T13452382 a4 3/9/18 28 T13452407 d2t 3/9/18 4 T13452383 a5 3/9/18 29 T13452408 d3 3/9/18 5 T13452384 a6 3/9/18 30 T13452409 d3t 3/9/18 6 T13452385 bl 3/9/18 31 T13452410 d4 3/9/18 7 T13452386 b2 3/9/18 32 T13452411 d5 3/9/18 8 T13452387 b3 3/9/18 33 T13452412 el 3/9/18 9 T13452388 b4 3/9/18 34 T13452413 fi 3/9/18 10 T13452389 cl 3/9/18 35 T13452414 Q 3/9/18 11 T13452390 c2 3/9/18 36 T13452415 Q 3/9/18 12 T13452391 c3 3/9/18 37 T13452416 f4 3/9/18 13 T13452392 c4 3/9/18 38 T13452417 f5 3/9/18 14 T13452393 c5 3/9/18 39 T13452418 f5a 3/9/18 15 T13452394 c6 3/9/18 40 T13452419 f6g 3/9/18 16 T13452395 c7 3/9/18 41 T13452420 f7g 3/9/18 17 T13452396 c8 3/9/18 42 T13452421 f8 3/9/18 18 T13452397 ci 3/9/18 43 T13452422 f8a 3/9/18 19 T13452398 Cj 1 3/9/18 44 T13452423 f9 3/9/18 20 T13452399 q3 3/9/18 45 T13452424 f9a 3/9/18 21 T13452400 q3a 3/9/18 46 T13452425 flo 3/9/18 22 T13452401 q3t 3/9/18 47 T13452426 fil 3/9/18 23 T13452402 cj 5 3/9/18 48 T13452427 f1 1 g 3/9/18 24 T13452403 q5t 3/9/18 49 T13452428 f12 3/9/18 25 T13452404 d1 3/9/18 50 T13452429 ft 1 3/9/18 This item has been electronically signed and scaled by ORegan, Philip using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by tt,111111111111MiTekUSA, Inc. under my direct supervision ,,%% 3 O'R I/,, based on the parameters provided by Mid -Florida Lumber Acquisitions, Inc.. Truss Design Engineer's Name: ORegan, Philip E N s My license renewal date for the state of Florida is February 28, 2019. No 58126FloridaCOA:6634 I MPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 4U13STATEOF 0 R Philip J. O'Regan PE No.58126 MlTek USA, Inc. FL Cerl 6634 6904 Parke East Blvd. Tampa FL 33610 March 9,2018 I of 2 ORegan, Philip I RE: P2392ACT - Park Sq/Barcelona-A or C—TRAY Site Information: Project Customer: PARK SQUARE HMS Project Name: P2392ACT Lot/Block: 197 Subdivision: WYNDHAM PRESERVE 40' Address: 3951 NIGHT HERON DR. City, County: SANFORD State: FLORIDA No. Seal# Truss Name Date 51 T13452430 ft2 3/9/18 52 T13452431 U 3/9/18 53 T13452432 ft4 3/9/18 54 T13452433 ft5 3/9/18 55 T13452434 gl 3/9/18 56 T13452435 g2 3/9/18 57 T13452436 g3 3/9/18 58 T13452437 3/9/18 59 T13452438 q41 3/9/18 60 T13452439 h2 3/9/18 61 T13452440 i2 3/9/18 62 T13452 41 j3 3/9/18 63 T134524 2 j5 3/9/18 64 T13452443 ff 3/9/18 65 T13452444 tVJ 3/9/18 66 T13452445 2 3/9/18 67 T13452446 kj3 3/9/18 68 T13452447 k15 3/9/18 69 T13452448 kj7 3/9/18 70 T13452449 kj7t 3/9/18 71 T13452450 M1 3/9/18 72 T13452451 m2 3/9/18 2 of 2 Job Truss Truss Type Qty Ply A or C_JRAYParkSqfflarcelona T13452444 P2392ACT 17T SPECIAL 3 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:21 2018 Page I ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-jjbOJDZ8UeQKO?QraoE7N5NTFJCIgMCqXJpOa2zcgau 1-0-0 2- 2 7-0-0 1_0 - 12 12 0_t 4-8-8 Scale = 1:21.7 2x4 LOADING (psf) SPACING- 2-0 CS1. TCLL 20.0 Plate Grip DOL 5J.; O TC 0.78 TCDL 1 0.0 Lumber DOL 1.25 BC 0.33 BCLL 0.0 Rep Stress Incr NO WEI 0.00 BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER- TOPCHORD 2x4 SP No.1 BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. lb/size) 4=214/Mechanical, 2=352/0-3-8,5=49/Mechanical Max Horz 2=143(LC 12) Max Uplift 4=-1 01 (LC 12), 2=-91 (LC 12) Max Grav 4=214(LC 1), 2=352(LC 1), 5=99(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. DEFL. in (loc) I/defl L/d PLATES. - GRIP Vert(LL) 0.20 3 >394 240 MT20 244/190 Vert(CT) -0.31 3 >263 180 Horz(CT) 0.16 5 n/a n/a Weight: 25 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 6-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 lb uplift at joint 4 and 91 lb uplift at joint 2. 6) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Rogan PE No.58126 MiTek USA, Ind. FL Cott 6634 6904 Parke East Blvd. Tampa FL 3361 D Date: March 9,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Ulf.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall IMF building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 FA Job Truss Truss Type Qty Fly Park Sq[Barcelona-A or C—TRAY T13452445 P2392ACT KJ2 JACK 2 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:23 2018 Page 1 ID:ItiEi_2vqrkv4uEJUYC2jFzkFng-f6j9jvbO?Fg2FIZDhDGbSWSzz6xYBGi7?dlVfxzcgas 561 1-5-0 4-0-1 2x4 Scale = 1: 11.5 LOADING (psf) SPACING- 2-0-0 CS1. DEFIL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.19 Vert(LL) -0.01 4-7 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.16 Vert(CT) -0.02 4-7 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP Weight: 15 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 4-0-1 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=94/Mechanical, 2=256/0-5-11, 4=47/Mechanical Max Horz 2=75(LC 8) Max Uplift 3=-49(LC 8), 2=-96(LC 8) Max Grav 3=94(LC 1), 2=256(LC 1), 4=70(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Part. Encl., GCpi=0.55; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 49 lb uplift at joint 3 and 96 lb uplift at joint 2. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 27 lb up at 1-6-12, and 3 lb down and 27 lb up at 1-6-12 on top chord, and 2 lb up at 1-6-12, and 2 lb up at 1-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). This item has been LOAD CASE(S) Standard electronically signed and1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 sealed by ORegan, Philip, PEUniformLoads (plf) Vert: 1-3=-60, 4-5=-20 using a Digital Signature. Concentrated Loads (lb) Printed copies of this Vert: 9=4(F=2, B=2) document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Ragan PE No.58126 MiTek USA, Ino. FL Cott 6634 6904 Parke East Blvd, Tampa FL 33610 Date; March 9,2018 WARNING Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 011711-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTelk(& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 If Job Truss Truss Type City Ply Park Sq/Barcelona-A or C—TRAY T13452446 P2392ACT KJ3 JACK 2 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52 24 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYG2jFzkFng-71H)(xFcOmZovtS8QFxnq?j?7iWGStjyHDH12BNzcgar 4-1-14 1 1_0 4-1-14 Scale = 1: 18.7 2X41 11 LOADING (psf]I SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.25 Vert(LL) 0.04 4-5 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.24 Vert(CT) 0.04 4-5 >999 180 BCLL 0.0 Rep Stress Incr NO WEI 0.00 Horz(CT) -0.06 3 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MR Weight: 17 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 4-1-14 oc purlins, BOTCHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=78/Mechanical, 5=231/0-11-5, 4=33/Mechanical Max Horz 5=127(LC 8) Max Uplift 3=-86(LC 8), 5=-1 49(LC 8), 4=-39(LC 8) Max Grav 3=78(LC 1), 5=231 (LC 1), 4=70(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (11b) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=1 40mph (3-second gust) Vasd=1 08mph; TCDL=4.2psf; BCDL=3.Opsf; h=1 5ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Part, Encl., GCpi=0.55 ' MWFRS (directional); end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 86 lb uplift at joint 3, 149 lb uplift at joint 5 and 39 lb uplift at joint 4. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 101 lb up at 1-6-12, and 101 lb up at 1-6-12 on top chord, and 45 lb up at 1-6-12, and 45 lb up at 1-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). This item has been electronically signed andLOADCASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 sealed by ORegan, Philip, PE Uniform Loads (plf) using a Digital Signature. Vert: 1-2=-60, 2-3=-60, 4-5=-20 Printed copies of this Concentrated Loads (1b) document are not considered Vert: 6=66(F=33, B=33) 7=7(F=3, B=3) signed and sealed and the signature must be verified on any electronic copies. Philio J. O'Regan PE No.58126 MiTek USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa Fl. 3361, D I)ate: March 9,2018 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall lei' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Streel, Suite 312, Alexandria, VA 22314. Tampa, FIL 36610 0 Truss Truss Type QtY Ply Park Sq/Barcelona-A or C—TRAY T13452447 KJ5 JACK 2 Job Reference (oOtional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Mar 9 10:52:25 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-bVqv8bceXtwmVcjcpel3XxX9ywVv'8r-ACQSxnbjpzcgaq 1-5-0 3-9-6 7-0-14 1_'_' 3-9-6 3-3-8 3x4 LOADING (ps SPACING. 2-0-0 CS1. TCLI _ 20.0 Plate Grip DOL 1.25 TC 0.80 TCDL 1 0.0 Lumber DOL 1.25 BC 0.60 BCLL 0. Rep Stress Incr NO WB 0.00 BCDL 10. Code FBC2017ITP[2014 Matrix -MP LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=183/Mechanical, 2=375/0-5-11, 4=95/Mechanical Max Horz 2=108(LC 8) Max Uplift 3=-79(LC 8), 2=-1 1 B(LC 8) Max Grav 3=183(LC 1), 2=375(LC 1), 4=129(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale= 1: 16.7 DEFL. in (loc) I/defl Ud PLATES GRIP Vert(LL) -0.11 4-7 >781 240 MT20 244/190 Vert(CT) -0.25 4-7 >341 180 Horz(CT) 0.00 2 n/a n/a Weight: 24 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 3 and 118 lb uplift at joint 2. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 11 lb up at 1-6-12, 3 lb down and 11 lb up at 1-6-12, and 3 lb down and 44 lb up at 4-4-12, and 3 lb down and 44 lb up at 4-4-12 on top chord, and 2 lb up at 1-6-12, 2 lb up at 1-6-12, and 5 111 down at 4-4-12, and 5 lb down at 4-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate ]ncrease=1.25 Uniform Loads (plf) Vert: 1-3=-60, 4-5 20 Concentrated Loads (11b) Vert: 10=4(F=2, B=2) 1 11 10(1`=-5, B=-5) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cent 6634 69D4 Parke East Blvd. Tampa FL 3361D Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 r— 1010312015 BEFORE USE. Design valid for use only with IviTek0 connectors. This design is based only upon parameters shown, and is for an individual building component, not F=4 Ell a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall kwo building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq/Barcelona-A or C—TRAY T13452448 P2392ACT KJ7 JACK 5 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:26 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-3hOHMxdGIA2d6mioNMql484RFKuvLYnZhaW9FFzcgap 1-5-1 5-2-5 9-10-13 o 5-2-5 4-8-8 l 2x4 1.5x4 11 5 3x4 = Scale = 1:21.9 LOADING (pso SPACING- 2-0-0 cSI. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.38 Vert(LL) 0.03 6-7 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.43 Vert(CT) 0.07 6-7 999 180 BCLL 0.0 Rep Stress Incr NO WB 0.36 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 42 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=128/Mechanical, 2=511/0-5-11, 5=328/Mechanical Max Horz 2=142(LC 8) Max Uplift 4=-70(LC 8), 2=-1 48(LC 8), 5 69(1_C 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-775/136 BOTCHORD 2-7=-208/708, 6-7=-208/708 WEBS 3-7=0/275, 3-6=-769/225 NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 4, 148 lb uplift at joint 2 and 69 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 11 lb up at 1-6-12, 3 lb down and 11 lb up at 1-6-12, 3 lb down and 44 lb up at 4-4-12, 3 lb down and 44 lb up at 4-4-12, and 27 lb down and 77 lb up at 7-2-11, and 27 Ito down and 77 lb up at 7-2-11 on top chord, and 2 lb up at 1-6-12, 2 lb up at 1-6-12, 5 lb down at 4-4-12, 5 lb down at 4-4-12, and 20 lb down at 7-2-11, and 20 lb down at 7-2-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: 1-4=-60, 5-8=-20 Concentrated Loads (lb) Vert: 13=-53(F=-27, B=-27) 14=4(F=2, B=2) 15=-10(F=-5, B=-5) 16=-35(F=-17, B=-17) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Ragan PE No.58126 Iii USA, Inc. FL Cott 6634 6904 Parke East Blvd, Tampa FIL 33610 Date: March 9,2018 WARNING - 11.rifyd-ignparameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(g) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPl1 Quality Criteria, DSB-89 and BCS] Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 f Job Truss Truss Type QtY Ply Park Sq/Barcelona -A or C — TRAY T134524 P2392ACT KJ7T SPECIAL 2 1 all Mid -Florida Lumber, Bartow, FL. 8' 130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:27 2018 Page 1 ID:ItiEL2vqrkv4uEJUYC2jFzkFng-XtytZHeu3UAUkwt?w3LXdMdVlj6b4O?jwEGioizcgao 3-2-2 6-4-11 9-10-131-5-0 2 1 1 1_1_ 3-2- 3-2-9 3-6-1 Scale = 1:21.4 99 4x4 = 3x4 11 LOADING (ps, TCLL 20.0 TCDL 10.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017frPI2014 CS1. TC 0.82 BC 0.92 WB 0.30 Matrix -MS DEFL. in (loc) I/defl Lid Vert(LL) -0.23 3-8 >521 240 Vert(CT) -0.47 3-8 >253 180 Horz(CT) 0.18 6 n/a n/a PLATES GRIP MT20 244/190 Weight: 40 lb FT = 20% LLIMBER- BRACING- TOPCHORD 2x4 SP DSS TOPCHORD Structural wood sheathing directly applied or 5-10-6 oc purlins. BOTCHORD 2x4 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 3-9: 2x4 SP No.3,3-6:2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 5=70/Mechanical, 2=500/0-5-11, 6=367/Mechanical Max Horz 2=142(LC 8) Max Uplift 5=-40(LC 8), 2=-1 48(LC 8), 6=-1 01 (LC 8) FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 3-4=-1015/253 BOTCHORD 3-8=-3121978, 7-8=-313/981 WEBS 4-8=-27/299, 4-7 1056/337 NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B, Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 40 lb uplift at joint 5, 148 lb uplift at joint 2 and 101 lb uplift at joint 6. This item has been 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 11 lb up at electronically signed and1-6-12, 3 111 down and 11 lb up at 1-6-12, and 33 lb down and 76 lb up at 7-2-11, and 33 lb down and 76 lb up at 7-2-11 on top sealed by ORegan, Philip, PEchord, and 2 lb up at 1-6-12, 2 lb up at 1-6-12, at 4-4-12, at 4-4-12, and 2 lb down at 7-2-11, and 2 lb down at 7-2-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. using a Digital Signature. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Printed copies of this document are not considered LOAD CASE(S) Standard signed and sealed and the 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 beUniformLoads (pif) signature must verified Vert: 1-3=-60, 3-5=-60, 9-10 20, 3-6=-20 On any electronic copies. Concentrated Loads (lb) Philip J. O'Regan PE No.58126 Vert: 14=-66(F=-33, B=-33) 15=4(F=2, B=2) 17=-2(F=-1, B=-1) MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIP7473 rev. 1010312015 BEFORE USE. De sign valid for use only with MiTek(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must vedfy the applicability of design parameters and propedy incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314 Tampa, FL 36610 I Job Truss Truss Type aty Ply Park Sq[Barcelona-A or C—TRAY T13452450 P2392ACT Mi JACK 1 at) Mid -Florida Lumber, Bartow, FL. 3x4 LOADING (pso SPACING- 2-0-0 CS1. TCLL 20. 0 Pla ' Grip DOLa 1.25 TC 0.42 TCDL 1 0.0 Lumber DOL 1.25 BC 0.86 BCLL 0. Rep Stress Incr NO WB 0.00 BCDL 10. Code FBC2017[TP12014 Matrix -MP 5-0-0 8,130 S Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:27 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-XtyfZHeu3UAUkwl?w3LXdMdbKj7Q44hjwEGioizcgao 2X4 11 Scale= 1: 17.0 DEFL. in (loc) I/defl L/d PLATES.: GRIP Vert(LL) -0.05 3-5 >999 240 MT20 244/190 Vert(CT) -0.10 3-5 >592 180 Horz(CT) 0.00 3 n/a n/a Weight: 23 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SID No.2 TOPCHORD BOTCHORD 2x6 SP No.2 WEBS 2x4 SP No.2 BOTCHORD REACTIONS. (lb/size) 1 =513/0-3-8, 3=597/Mechanical Max Horz 1 =81 (LC 8) Max Uplift I =-1 1 O(LC 8), 3=-1 77(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown Structural wood sheathing directly applied or 5-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or B-0-9 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=25ft; B=45ft; L=24ft, eave=4ft; Cat. 11; Exp B; Encl., GCpi=O.l 8; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint I and 177 lb uplift at joint 3. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 116 111 down and 41 lb up at 1-1-13, and 606 lb down and 181 lb up at 3-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1 .25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-60, 1-3=-20 Concentrated Loads (lb) Vert: 5=-1 16(B) 6=-606(B) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Inc. FL Cart 6634 6904 Parke East Blvd, Tampa FIL 3361D Date: March 9,2018 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 te, 1010312015 BEFORE USE. Design valid for use only with MiTelk(l) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fa th ricat ion, storage, delive ry, erection and bra ci ng of tru sses and tru ss system s, see ANSI/TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 001, Job Truss Truss Type QtY Ply Park Sq/Barcelona-A or C—TRAY T13452451 P2392ACT M2 JACK 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 4I U4 5-0-0 8.130 s Sep 15 2017 MiTek Industries, Inc. Fin Mar 9 10:52:28 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-?4W2ndfXqoJLM4SBUnsm9Z9ni7alpXxs8u?GK8zcgan 2X4 11 Scale = 1:17.0 LOADING (psf) TCLL 20.0 TCDL 10.0 BCLL 0.0 BCDL 10.0 SPACING-. 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017/TP12014 CS1. TC 0.34 BC 0.44 WB 0.00 Matrix -MP DEFL. in (loc) I/defl Ud Vert(LL) -0.03 3-5 >999 240 Vert(CT) -0.06 3-5 >972 180 Horz(CT) 0.00 3 n/a n/a PLATES GRIP MT20 244/190 Weight: 23 lb FT = 20% LUMBER- BRACING. TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 5-0-0 oc purlins, BOTCHORD 2x6 SP No.2 except end verticals. WEBS 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=463/0-3-8,3=349/Mechanical Max Horz 1 =81 (LC 8) Max Uplift 1 =-1 21 (LC 8), 3=-1 25(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf ' BCDL=3.Opsf; h=25ft, B=45ft, L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=O.l 8; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 121 lb uplift at joint 1 and 125 lb uplift at joint 3. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 235 lb down and 92 lb up at 0-10-12, and 188 lb down and 88 lb up at 2-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). This item has been electronically signed andLOADCASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 sealed by ORegan, Philip, PE Uniform Loads liplf) using a Digital Signature. Vert: 1-2=-60, 1-3=-20 Printed copies of this Concentrated Loads (lb) document are not considered Vert: 5=-235(F) 6=-188(F) signed and sealed and the signature must be verified on any electronic copies. Philip J. URegan PE No.58126 MiTak USA, Inc. Fl. Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 AWARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE, Design valid for use only with MiTeOD connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Nil' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek" fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSS-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 IF Job Truss Truss Type Qty Ply Park SqfBarcelona-A or C—TRAY T13452380 P2392ACT At HIP 1 2 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:22 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-xNX5w2r7NW iRwPVdvgHUeQObX—OLXh9zdOmOzzcgbp 0-1'3 11.34-,0 1 §110-0 Ll -31 -33 25475 3_ 4 3'_04-1-1 4-3-3 THIS TRUSS IS NOT SYMMETRIC. 4x8 = PROPER ORIENTATION IS ESSENTIAL. 4x5 19 14 13 12 11 10 9 4x10 3XS 7x6 4x5 3x8 7x6 2x4 Scale = 1:50.9 4x10 = 4': 19 = 1, 1, 1 3 1 V V31 Plate Offsets (X,Y)— fl:0-5-0.0-1-71, [4:0-5-4,0-2-01, [8:0-5-0,0-1-71, 10:0-3-0,0-5-01, [13:0-3-0,0-4-121 LOADING (psf) SPACING- 2-0-0 cSI. DEFL. in loc) - I/defl L/d PLATES-- GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.81 Vert(LL) -0.23 12-13 >999 240 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.72 Vert(CT) -0.46 12-13 >792 180 BCLL 0.0 Rep Stress Incr NO WEI 0.63 Horz(CT) 0.13 8 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 398 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 2-8-12 oc purlins. BOTCHORD 2x6 SP DSS *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 10-13: 2x6 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1 =6305/0-3-8, 8=601 1 /Mechanical Max Horz 1=137(LC7) Max Uplift 1 1760(1_C 8), 8 1695(1_C 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-1 1838/3391, 2-3=-9838/2913, 3-4=-7860/2387, 4-5=-7140/2203, 5-6=-7969/2413, 6-7=-10128/2961, 7-8=-12088/3443 BOTCHORD 1-14=-2985/10568, 13-14=-2985/10568, 12-13=-2474/8723, 11-12=-1954/7033, 10-11=-2517/8978, 9-10=-3031/10793, 8-9=-3031/10793 WEBS 2-14 373/1607, 2-13=-2070/572, 3-13=-692/2475, 3-12=-2573/793, 4-12=-933/3087, 4-11 1 39/367, 5-11 =-990/3329, 6-11 =-2801/819, 6-1 0 724/2729' 7-1 0=-2031/576, 7-9=-375/1568 NOTES- 1) 2-ply truss to be connected together with 10d (0.1 31"x3") nails as follovvs Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - I row at 0-9-0 oc. This item has been 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to electronically signed and ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. sealed by ORegan, Philip, PE3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf, h=25ft; B=45ft; L=30ft; eave=4ft; Cat. using a Digital Signature. 11; Exp B; Encl., GCpi=0.18; MWIFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 Printed copies of this 5) Provide adequate drainage to prevent water ponding. document are not considered 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. signed and sealed and the7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide signature must be verifiedwillfitbetweenthebottomchordandanyothermembers. 8) Refer to girder(s) for truss to truss connections. On any electronic copies. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except ot=lb) Philip J. O'Regan PE No.56126 1=1760,8=1695. MiTek USA, Inc. I'L Cort 6634 6904 Parke East Blvd. Tampa FIL 33610 Date; March 9,2018 CWiv ft"P(9.ugp,gesignpammefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 — 1010312015 BEFORE USE. Design valid for use only with MiTekV connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Bet building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FIL 36610 or Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452380 P2392ACT At Hip 1 2 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:22 2018 Page 2 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-xNX5w2r7NW—iRwPVdvgHUeQObX—OLXh9zdOmOzzcgbp NOTIES- 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 640 lb down and 165 lb up at 0-4-0, 624 lb down and 174 lb up at 2-4-0, 624 lb down and 174 lb up at 4-4-0, 624 lb down and 174 lb up at 6-4-0, 619 lb down and 228 lb up at 8-4-0, 619 lb down and 210 lb up at 10-4-0, 616 lb down and 209 lb up at 12-4-0, 611 lb down and 221 lb up at 14-4-0, 611 lb down and 221 lb up at 15-10-0, 616 lb down and 209 lb up at 17-10-0, 619 lb down and 210 lb up at 19-10-0, 616 lb down and 180 lb up at 20-7-4, 616 lb down and 180 lb up at 22-74, 616 lb down and 180 lb up at 24-7-4, and 616 lb down and 180 11b up at 26-7-4, and 616 lb down and 182 lb up at 28-7-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate Increase=1.25 Uniform Loads (pl Vert: 1-4=-60, 4-5=-60, 5-8=-60, 1-8=-20 Concentrated Loads (lb) Vert: 19=-640(F) 2u=-624kf-) 2 1 =-624(F) 22=-624(F) 23=-619(F) 24=-619(F) 25=-616(F) 26=-61 1 (F) 27=-61 1 (F) 28=-616(F) 29=-619(F) 30=-616(F) 31 =-616(F) 32=-616(F) 33=-616(F) 34=-616(F) WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 r— 1010312015 BEFORE USE. Design valid for use only with MiTekqD connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Dal' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 IP Job Truss Truss Type oty Ply Park Sq/Barcelona-A or C TRAY T13452381 P2392ACT A2 HIP 1 Job Refer Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 es, Inc. Fri Mar 9 10:51:22 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-xNX5w2r7NW—iRwPVdvgHUeQSwX3[LZ09zdOmOzzcgbp 12-0-0 18-2-0 23-10-12 30-2-0 1-2-0 5, 21-31 5-8-12 6-2-0 6-3-4 Scale = 1:52.2 5x5 3 21 22 23 5x5 4 12 11 __ . - 9 b 3x4 1 X4 11 3x4 3X4 3x8 1 X4 11 3x4 5-3 :1 0 0 22_1 12 0i 31 5 2' W8 5-0 2 t3 Plate Offsets (X,Y)— [3:0-2-8,0-2-41, [4:0-2-8,0-2-41 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defli L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) 0.05 12-15 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.44 Vert(CT) 0.11 12-15 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.46 Horz(CT) 0.02 9 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 152 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 5-5-11 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-9 REACTIONS. (lb/size) 1=587/Mechanical, 9=1575/0-3-8, 6=312/0-3-8 Max Horz 1=-132(LC 10) Max Uplift 1=-143(LC 12), 9=-365(LC 12), 6=-109(LC 12) Max Grav 1 =615(LC 21), 9=1 575(LC 1), 6=369(LC 22) FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-956/312, 2-3=-424/198, 3-4=0/407, 4-5=-78/539, 5-6=-271/136 BOTCHORD 1-12=-1 94/827, 11-12=-194/827, 9-11 =0/317 WEBS 2-12=0/251, 2-11 =-588/261, 3-11 =-89/461, 3-9=-912/314, 4-9=-550/243, 5-9=-586/260, 5-8=0/251 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf, BCDL=3.Opsf; h=25ft; B=45ft, L=30ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-3, Interior(l) 3-0-3 to 12-0-0, Exterior(2) 12-0-0 to 22-5-3, Interion(l) 22-5-3 to 31-2-0 zone,C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. This item has been 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide electronically signed andwillfitbetweenthebottomchordandanyothermembers, with BCDL = 1 O.Opsf. sealed by ORegan, Philip, PE6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) using a Digital Signature. 1=143,9=365,6=109. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke EaSt Blvd. Tampa FL 33610 Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111.7473re, 1010312015 BEFORE USE. Design valid for use only with MiTekQD connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system, Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall all* building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Sute 312, Alexandra, VA 22314. Tampa, FL 36610 r Job Truss Truss Type oty Ply Park Sq/Barcelona-A or C—TRAY T13452382 P2392ACT A4 HIP 1 Job Reference (ootional) Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:23 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-PZ5T80si8p6Z34—hAdBWlsze—wNg4xV,ACHmJYPzcgbo 15-1-0 44- 2 30-2-0 1-2-0001-9 — 5-_2 112 5-9-4 1-0-04-1-0 Scale = 1:51.2 4X4 3x4 4x4 3 21 4 225 IT9 12 11 10 9 3x4 lx4 5X8 3X8 lx4l 3x4 4 1 -0 1110 1' 0 511 i-Y2 4;0 3-6-V 1 1 1 Plate Offsets (X,Y)— [11 0-4-0,0-3-01 LOADING (psf) SPACING- 2-0-0 CS1. DIEFL. in (loc) I/defl Ud PLATES-, GRIP TCLL 20.0 Plate Grip DOIL 1.25 TC 0.45 Vert(LL) 0.09 10-11 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.46 Vert(CT) 0.18 10-11 >999 180 BCLI_ 0.0 Rep Stress Incr YES W3 0.79 Horz(CT) 0.02 10 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 156 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 5-4-9 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=616/Mechanical, 10=1595/0-3-8,7=262/0-3-8 Max Horz 1=-122(LC 10) Max Uplift 1 =-I 51 (LC 12), 1 0=-367(LC 12), 7=-99(LC 12) Max Grav 1 =641 (LC 21), 1 0=1 595(LC 1), 7=317(LC 22) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-1039/351, 2-3=-543/234, 3-4 411/257, 4-5=-30/471, 5-6=-98/572 BOTCHORD 1-12=-2341892, 11-12=-234/892 WEBS 2-11 =-546/255, 5-1 0=-475/195, 6-1 0=-547/254, 4-11 =-1 61/570, 4-1 0=-884/336 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft, L=30ft; eave=4ft; Cat. 11; Exio B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-3, Interior(l) 3-0-3 to 11-0-0, Exterior(2) 11-0-0 to 23-5-3, Interior(l) 23-5-3 to 31-2-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide This item has been will fit between the bottom chord and any other members, with BCDL = I O.Opsf. electronically signed and6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except at=lb) sealed by ORegan, Philip, PE 1=151,10=367. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9.2018 AWARNING- Verity design parameters andREADNOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 r— 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall NEI' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Instilute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 r Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452383 P2392ACT A5 HIP 1 1 Job Reference (optional) Mid-l-londa Lumber, banoW, l--L. b.iiu s zep iti zui I mi I eK mausmes, Inc. rn mar , IU:D I:Z4 eU]t$ vage i ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-tmfrLktNv7EQgEZukKiIZ3Wp?KeKpSrRQxVt4rzcgbn 15-1-0 Zl -2-0 5_4-1 2 30-2-0 1 -2O9-0-0 i iF_ 6-1-04-11 -12 -2 12 4-9-4 Scale = 1:51.1 4 4x4 = 3 20 21 3x8 4 22 23 44 = 12 11 10 9 3X8 3x8 5x5 3x8 3x8 Tc? 16 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.50 Vert(LL) 0.16 9-18 868 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.82 Vert(CT) 0.37 9-18 369 180 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(CT) 0.07 7 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 149 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOTCHORD 2x4SPNo.1 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1072/Mechanical, 7=1049/0-3-8, 10=35310-3-8 Max Horz 1=-101(LC 10) Max Uplift 1=-254(LC 12), 7=-277(LC 12), 10=-86(LC 12) BRACING- TOPCHORD Structural wood sheathing directly applied or 3-10-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 8-4-9 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-1983/711, 2-3=-1683/595,3-4=-1461/580, 4-5=-1250/505,5-6=-1452/514, 6-7=-1765/634 BOTCHORD 1-12=-564/1751, 11-12=-413/1573, 10-11=-413/1573, 9-10=-413/1573, 7-9=-505/1562 WEBS 2-12=-344/226, 3-12=-105/479, 4-12=-264/76, 4-9=-502/175, 5-9=-65/407, 6-9=-364/233 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=O.l 8; MWIFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-3, lnterior() 3-0-3 to 9-0-0, Exterior(2) 9-0-0 to 25-6-11, Interiori 25-6-11 to 31-2-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10 except Ot=lb) 1=254,7=277. WARNING- Verify design parameters andREAD NOTES ON THISAND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(g) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Ragan PE No.58126 MiTek USA, Inc. FL Cod 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 ail' M!Tek' 6904 Parke East Blvd. Tampa, FL 36610 01 Job Truss Truss Type QtY Ply Park Sq/Barcelona-A or C—TRAY T13452384 P2392ACT A6 HIP I Job Reference (optionall Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Mar 9 10:51:26 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-q8mcmQveRkV8wYjGsliDeUb5x8QPHG6kuF_9kzcgbI 1-0 15-1-0 18-11-0 Z3-2-0 26-4-12 0-2-0 1-2-00L0-01 _ 0 '_'_0 '_7_0 3_2_2 -n3-211 -_2 --1'2 41 1_0 Scale = 1:52.4 3x4 = 4x8 1.5x4 h 4x8 1.5X4 1 4 23 245 25 6 26 7 27 28 4x8 = 16 __ 15 - . 14 13 12 3x4 = 6X8 = 5x5 = 6x8 = 3X4 = 1' _-8-0 1 t4V70- 7-11-1 W 3 4 M % __1 3X4 = A LOADING (ps SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) 0.05 16-19 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.40 Vert(CT) 0.12 16-19 999 180 BCLL 0.0 Rep Stress Incr NO WB 0.93 Horz(CT) 0.03 10 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 161 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOTCHORD 2x4SPNo.lD WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1076/0-3-8, 13=2996/0-3-8, 10=364/0-3-8 Max Horz 2=82(LC 7) Max Uplift 2=-326(LC 8), 13=-880(LC 8), 1 0=-1 17(LC 8) Max Grav 2=1086(LC 17), 13=2996(LC 1), 10=382(LC 18) BRACING- TOPCHORD Structural wood sheathing directly applied or 4-1-5 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1920/562,3-4=-1711/512,4-5=-1191/397,5-6=-1191/397,6-7=-272/1116, 7-8=-272/1116,9-10=-389/107 BOTCHORD 2-16=-435/1694,15-16=-361/1513,14-15=-68/282,13-14=-68/282,10-12=-31/335 WEBS 3-16=-273/109, 4-16=-73/641, 4-15=-426/112, 5-15=-490/251, 6-15=-38411293, 6-13=-1914/558, 7-13=-512/258 8-13=-1537/439, B-12=-75/644, 9-12=-279/1 18 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wnd: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft, eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18, MWFRS (directional); Lumber DOL=11.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads, 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=326,13=880,10=117. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 189 lb down and 206 lb up at 7-0-0, 97 lb down and 106 lb up at 9-0-12, 97 lb down and 106 lb up at 11-0-12, 97 lb down and 106 Ib up at 13-0-12, 97 lb down and 106 lb up at 15-1-0, 97 lb down and 106 lb up at 17-1-4, 97 lb down and 106 lb up at 19-1-4, and 97 lb down and 106 lb up at 21-1-4, and 189 lb down and 206 lb up at 23-2-0 on top chord, and 327 lb down and 97 lb up at 7-0-0, 66 lb down at 9-0-12, 66 lb down at 11-0-12, 66 lb down at 13-0-12, 66 lb down at 15-1-0, 66 lb down at 17-1-4, 66 lb down at 19-1-4, and 66 lb down at 21-1-4, and 327 lb down and 97 lb up at 23-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: 1-4=-60, 4-8=-60, 8-11 =-60, 17-20=-20 Cwam'Rompp, 3esign parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473n., 1010312015 BEFORE USE. Design valid for use only with MiTek(& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPIl Quality Criteria, DSB.89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. gRagan PE No.56126 MiTak USA, Inc. FL Cent 6634 69U Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type QtY Ply Park Sci/Barcelona-A or C—TRAY T13452384 Job P2392ACT A6 HIP 1 1 Reference (optional) Mid -Florida Lumber, Bartow, FL. 8,130 S Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:26 2018 Page 2 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-q8mcmQveRkVBwYiGsliDeUb5x8QPHG6kuF-9kzcgbI LOAD CASE(S) Standard Concentrated Loads (1b) Vert: 4=-1 42(F) 8=-1 42(F) 16=-327(F) 14=41 (F) 6=-97(F) 12=-327(F) 23=-97(F) 24=-97(F) 25=-97(F) 26=-97(F) 27=-97(F) 28=-97(F) 29=41 (F) 30=41 (F) 31 =41 (F) 32 =-41 (F) 33=-41 (F) 34=41 (F) WARNING - Venitydeignp.—efers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev, 1010312015 BEFORE USE. MAINDesignvalidforuseonlywithMiTekOconnectors. This design is based only upon parameters shown, and is for an inclMdual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall MM building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 91 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452385 P2392ACT B1 SPECIAL 1 2 Job Reference (ootional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Mar 9 10:51:27 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-ILK — zmvGB2d?XiHSPTGSBiBDOYhFOiqu7vkXhAzcgbk 4- 5 1 B-2-13 12-1-0 -7- 4-5-4 1_11-4 1 l-_24 1 1_14 1 24-41F11--00 4 11 1 1 -2-14 2-7-15 2 2- 2- _0 2- _ 2_7_ 4 _ Scale = 1:47.3 1.5x4 1.5x4 5 1.5x4 3x4 IV Ib I / it) to 14 1 12 2x4 8x10 2X4 6x8 2X4 2x4 8x8 3x4 1 4=1-11 1 1 4 11 4 1 4 2-'1-1 3'101 IN 1 IM B! 3-- 220 2 2 Plate Offsets (X,Y)— [2:0-1-8,Edgel, [6:0-4-12,Edgel, [18:0-5-0,0-5-01, [21:0-2-0,0-2-01 LOADING (psf) 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.00 TC 0.94 Vert(LL) -0.42 16-17 >697 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.74 Vert(CT) -0.80 16-17 >361 240 MT20HS 1871143 BCLL 0.0 Rep Stress Incr NO WIB 0.96 Horz(CT) 0.06 12 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 314 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 *Except* TOPCHORD Structural wood sheathing directly applied or 2-1-8 oc purlins, 6-11: 2x4 SP No.1 except end verticals. BOTCHORD 2x6 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 12-18:2x6 SP DSS WEBS 2x4 SP No.3 *Except* 6-18: 2x4 SP No.2 REACTIONS. (lb/size) 12=1607/0-4-0, 2=1448/0-8-0 Max Horz 2=187(LC 12) Max Uplift 12=-79(LC 12), 2=-176(LC 12) Max Grav 12=1972(LC 2), 2=1518(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2898/684, 3-4=-2631/654, 6-7=-1 159012868, 7-8=-1 1590/2868, 8-9=-8962/1904, 9-10=-4075/751, 10-11=-4075/751, 11-12=-1680/305 BOTCHORD 2-19=-778/2579, 18-19=-778/2579, 17-18=-3038/11202, 16-17=-3126/11496, 15-16=-1 904/8962, 14-15=-1 904/8962, 13-14=-1 90418962, 12-13=-55/303 WEBS 6-17=-617/223, 7-16=-586/168, 8-15=-1028/309, 9-14=-32911286, 6-16=-335/401, B-16=-1033/2814, 11-13=-746/4039, 9-13=-5268/1235, 4-18=-940/3539, 6-18=-9284/2467, 3-18=-339/130, 4-6=-3471/1012 NOTES- - 1) 2-ply truss to be connected together with 10d (0.1 31"x3") nails as follows: This item has been Top chords connected as follows: 2x4 - I row at 0-7-0 oc. electronically signed andBottomchordsconnectedasfollows: 2x6 - 2 rows staggered at 0-9-0 oc. sealed by ORegan, Philip, PEWebsconnectedasfollows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to using a Digital Signature. ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. Printed copies of this 3) Unbalanced roof live loads have been considered for this design. document are not considered 4) Wind: ASCE 7-10; Vult=1 40mph (3-second gust) Vasd=l 08mph; TCDL=4.2psf. BCDL=3.Opsf; h=1 5ft; B=45ft. L=24ft, eave=4ft; Cat. signed and sealed and the 11; Exp B; Encl., GCpi=O. 18; MWFRS (directional) and C-C Exterior(2) -1 -0-0 to 2-0-0, Interior(l) 2-0-0 to 11-11-4, Exterior(2) 12-1 -0 signature must be verifiedto15-1-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. on any electronic copies. 6) All plates are MT20 plates unless otherwise indicated. Philip J. VRegan PE No.58126 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. MiTek USA, Inc. FL Cort 6634 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide 6904 P ' arke East Blvd. Tarnpa FL 3361 D will fit between the bottom chord and any other members. Date: 9) Provid e mechan ical corm ection (by others) of tru ss to bearing plate capable of withstand ing 100 lb u plift at joint(s) 12 except at= lb) March 9,2018 2=1 76. A AND INCLUDED MITEK REFERENCE PAGE Ull-7473 rev. 1010312015 BEFORE USE. CVftWQA6)arP,9@@4 with MiTek& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 N Job Truss Truss Type aty Ply Park Sq/Barcelona-A or C_:rRAY T13452385 P2392ACT Bi SPECIAL 1 2 Job Reference (optional) Mid-Flodda Lumber, Bartow, FL. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-5=-60, 6-1 1=-90, 2-12=-20 Concentrated Loads (lb) Vert: 25=-706 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Mar 9 10:51:27 2018 Page 2 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-ILK—zmvGB2d?XiHSPTGSBi8DOYhFOiqu7vkXhAzcgbk A WARNING -Verify design parameters and READ NOrES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekID connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design . Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage, For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type QtY Ply Park Sq[Barcelona-A or C—TRAY T13452386 P2392ACT B2 SPECIAL 1 2 Job Reference (ootional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:28 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-mXuMB6wuyMis9rsfzAnhjvgN6x2Hl9olLZT4Ddzcgbj 1-1-0-0 i 5-9-4 1 -0-0 1 1-1-8 i 11-11,12 1 1,7 5-12 1,1-2,,4 _l -8-4 24-4-0 0_0 5-9-4 2-12 1_,_8 2, _0 2'_0 2-7-1 Scale = 1:42.8 c? 5x8 3X4 11 3x4 = — . I — 12 2X4 4x6 5X10 = 4X4 11 5X8 2x4 11 2x4 11 8X8 3x4 i i i 1 _1;3 i 1 J- J2 :F 22 TI-1 WO11:11 5 2 2 2 1-1 2 AOADING (psf]I. SPACING- 2-0-0 CS1. DEFL. in (loc) Ildef] Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.00 TC 0.94 Vert(LL) 0.45 16-17 >650 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.69 Vert(CT) 0.87 16-17 >334 240 BCLL 0.0 Rep Stress Incr NO WB 0.98 Horz(CT) 0.06 12 n/a n/a BCDL 10.0 Code FBC2017[TP12014 Matrix -MS Weight: 301 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 1-11-14 oc purlins, BOTCHORD 2x6 SP No.2 *Except* except end verticals. 12-19: 2x6 SP DSS BOTCHORD Rigid ceiling directly applied or 9-10-1 oc bracing. WEBS 2x4 SP No.3 *Except* 5-17,4-18,6-18: 2x4 SP No.2 REACTIONS. (lb/size) 12=1597/0-4-0, 2=1456/0-8-0 Max Horz 2=324(LC 12) Max Uplift 12=-100(LC 12), 2 166([_C 12) Max Grav 12=1993(LC 17), 2=1549(LC 17) FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3046/702, 3-4=-2350/542, 6-17=-437/191, 6-7=-1 1474/2937, 7-8=-1 1474/2937, 8-9=-8986/2008,9-10=-4121/818, 10-11=-4121/818,11-12=-1684/329 BOTCHORD 2-20=-982/2813. 18-20=-982/2813,17-18=-3332/11833, 16-17=-3590/12573, 15-16=-2008/8986,14-15 2008/8986, 13-14=-2008/8986, 12-13=-58/301 WEBS 3-20 36/380, 3-1 8=-747/283, 4-18=-2042/7526, 4-6=-6957/2050, 6-18 1 1674/3135, 7-16=-353/44,8-15=-1006/318,9-14=-356/1336,6-16=-1271/699,8-16=-994/2665, 11 -1 3=-814/4091. 9-13=-5211/1275 NOTES- 1) 2-plytrussto be connected together with 10d (0.131"x3") nails asfollows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - I row at 0-9-0 oc, Except member 18-6 2x4 - 1 row at 0-7-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 11-0-0, Exterior(2) 11-0-0 to 12-5-12, Interior(l) 12-5-12 to 24-2-4 zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=11.60 5) Provide adequate drainage to prevent water poncling. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) 12 except at=lb) 2=166. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) . The design/selection of such This item has been electronically signed and sealed by CiRegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 C a. n and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473 r— 1010312015 BEFORE USE. QVnW91T!e%aRRTek,& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPH Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Insfitute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C_TRAY T13452386 P2392ACT B2 SPECIAL I 2 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:28 2018 Page 2 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-mXuMB6wuyMlsgrsfzAnhjvgN6x2Hl9olLZT4Ddzcgbj LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plo Vert: 1-4=-60, 4-5=-60, 6-11 =-90, 2-12=-20 Concentrated Loads (lb) Vert: 6=706 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 r-. 1010312015 BEFORE USE. Design valid for use only with MiTek(EDconnectors. This design is b a sed only upon parameters shown, and is for an individual building com pone nt, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply Park Sq/Barcelona-A or C—TRAY T13452387 P2392ACT B3 SPECIAL 1 2 Job Referenre (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Mar 9 10:51:29 2018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-EjSkORxVVjftjn?RrXulwG7DYjLMbUdZBaDDem3zcgbI 9-0-0 2 7-1 14-11-12 1 1 7-1-012 IT9-2-4 21 -'14 2 4-0 4-2-12 _' i 2" 2_ _0 _'_J137 4 4x8 = 24 1.5X4 11 25 5 Scale = 1 43.3 3x4 = 2x4 11 8X10 = 4x4 11 5X8 = 2x4 11 2x4 11 8X8 = 3x4 11 2 1 12- -'2 1p__m'l i 1- 14-141RI2V '_0 24-1-4 4-M2 Plate Offsets X Y)— [4:0-5-4,0-2-01, f670-2-8,0-3-41, [18:0-3-12,0-5-41 ly LOADING (psf]) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.00 TC 0.95 Vert(LL) 0.42 16-17 699 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.75 Vert(CT) 0.80 16-17 361 240 BCLL 0.0 Rep Stress Incr NO WB 0.95 Horz(CT) 0.06 12 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Weight: 295 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x6 SP DSS *Except* 2-18: 2x6 SP No.2 BOTCHORD WEBS 2x4 SP No.3 *Except* 6-18: 2x4 SP No.2 REACTIONS. (lb/size) 12=1597/0-4-0, 2=1456/0-8-0 Max Horz 2=263(LC 12) Max Uplift 12=-90(LC 9), 2=-1 78(LC 12) Max Grav 12=1 981 (LC 17), 2=1 547(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2988/757, 3-4=-2716/703, 6-17=-507/205, 6-7=-1 1386/2822, 7-8=-1 1386/2822, 8-9=-8918/1931, 9-1 0=-4095/788, 10-11 =-4095/788, 11-12=-1 674/318 BOTCHORD 2-19=-963/2751, 18-19=-963/2751, 17-18 =-3207/11635, 16-17=-3415/12316, 15-16=-1 931/8918, 14-15=-1 931/8918, 13-14=-1 931/8918, 12-13=-56/299 WEBS 3-18=-354/158, 4-18=-870/3322, 4-6=-3259/992, 6-18=-9508/2471, 9-14=-341/1325, 8-15=-1007/308, 7-16=-342/38, 6-16=-1 173/634, 8-16=-955/2643,11-13=-784/4065, 9-13=-5165/1224 Structural wood sheathing directly applied or 1-11-5 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) 2-ply truss to be connected together with 10d (0.1 31"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft ' eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interion(l) 2-0-0 to 9-0-0, Exterior(2) 9-0-0 to 12-0-0, Interion(l) 12-5-12 to 24-2-4 zone,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12 except at=lb) 2=1 78. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) . The design/selection of such This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. gRegan PE No.58126 MiTek USA, Ina. F L Carl 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 C t. Vq;RR r. t.r. and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. WIN19f I e WXRme`k(D connectors. This design is based only upon parameters shown, and is for an individual building component, not truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overallI MiTek' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job T ss Truss Type MY Ply Park Sq/Barcelona-A or C—TRAY T13452387 P2392ACT B3 SPECIAL 1 2 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:29 2018 Page 2 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-EjSkORxVVjftjn?RrXu[wG7DYjLMbUdZBaDDem3zcgbi LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-4=-60, 4-5=-60, 6-11 =-90, 2-12=-20 Concentrated Loads (lb) Vert: 6=-706 WARNING Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with M!Tek& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall NEI' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexa ndna, VA 22314 Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq[Barcelona-A or C—TRAY T13452388 P2392ACT B4 SPECIAL 1 3 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. U.1 u s iep lb zui I mt i eK inoustnes, Inc. t-n mar V iu::)i:Ju zul'5 vage I ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-ivO6cny8Uz?ZP9015bp9pKmjslhdD7dKptyBlVzcgbh 7-1-0 1-11- 2-7-1 1 -11-12 li7:65-02 19-82 1-84 -01___ 1 4__ 1 1 -4 2__ 24-_460_--o0 _2_, 2 2_,_, 2" _B 2_6_0 2_7_li Scale = 1:43.3 4x8 4x6 25 5 26 2X4 6 1 13 3X4 2X4 3x4l 4x6 4X4 5x8 2X4 2X4 11 6X9 3X4 7xl 0 = i iz':' 10 JI ' 1 1- 1 7 1 2 117211411 to3-11 3-Z 2-11 , 1 1 hl _02 247- 2 Plate Offsets (X,Y)— [4:0-5-4,0-2-01, f7:0-3-4,0-3-41, [19:0-5-0,0-4-81 LOADING (psf]i SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.00 TC 0.92 Vert(LL) -0.42 17-18 >687 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.83 Vert(CT) -0.82 17-18 >355 180 BCLL 0.0 Rep Stress Incr NO WB 0.77 Horz(CT) 0.07 13 n/a n/a BCDL 10.0 Code FBC2017/TP[2014 Matrix -MS Weight: 448 lb FT = 20% LLIMBER- BRACING- TOPCHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 3-1-9 oc puffins, 7-12: 2x4 SP No.1 except end verticals. BOTCHORD 2x6 SP DSS *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 2-20: 2x6 SP No.2 WEBS 2x4 SP No.3 *Except* 6-18,7-19,7-17,9-17,12-14,10-14: 2x4 SP No.2 REACTIONS. (lb/size) 13=2529/0-4-0, 2=2354/0-8-0 Max Horz 2=202(LC 8) Max Uplift 13=-341 (LC 5), 2=-446(LC 8) Max Grav 13=3512(LC 2), 2=2376(LC 2) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-4910/871, 3-4=-4708/875, 4-5=-5375/945, 5-6=-337/33, 7-18=-1611317, 7-8=-1 8798/2775, 8-9=-1 8798/2775, 9-1 0=1 4658/1864, 10-11 =-6849/755, 11-12=-6849/755, 12-13=-2685/299 BOTCHORD 2-22=-921/4371, 21-22=-921/4371, 19-21 =-863/4198, 18-19=-3139/18876, 17-18=-3316/19968, 16-17=-1 864/14658, 15-16=-1 864/14658, 14-15=-1 864/14658, 13-14=-49/464 WEBS 3-21 =-283/69, 4-21 =-71/502, 4-19=-232/1843, 5-19=-770/4820, 5-7=-7118/1291, 7-19=-14443/2278, 7-17=-2256/579, 9-16=-1503/309, 9-17=-976/4758, 10-15=-321/2328, 12-14=-756/6838, 10-14=-8364/1188 NOTES- 1) 3-ply truss to be connected togetherwith 10d (0.131"xY) nails as follows: Top chords connected as follows: 2x4 - I row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108rnph; TCDL=4.2psf; BCDL=3.Opsf ' h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional), Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 13=341,2=446. C and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTelke connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPIl Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J 0 ' 'Regan PE No.58126 MiTDk USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 MiTek* 6904 Parke East Blvd. Tampa, FL 36610 Job T ss Truss Type QtY Ply Park Sq/Barcelona-A or C — TRAY T13452 P2392ACT B4 SPECIAL 1 3 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.13D s Sep 15 2017 MiTelk Industries, Inc. Fri Mar 9 10:51:30 2018 Page 2 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-ivO6cny8Uz?ZP9015bp9pKmjslhdD7dKptyBlVzcgbh NOTES- 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 189 lb down and 204 111 up at 7-0-0, and 97 lb down and 106 lb up at 9-0-12, and 97 lb down and 106 lb up at 11-0-12 on top chord, and 327 lb down and 97 lb up at 7-0-0, 66 lb down at 9-0-12, 66 Ito down at 11-0-12, 344 lb down at 14-9-12, 344 lb down at 16-9-12, 344 lb down at 18-9-12, 344 lb down at 20-9-12, 344 lb down at 22-9-12, and 354 lb down at 24-2-4, and 1136 lb down and 201 lb up at 12-9-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-4=-60, 4-6=-60, 7-12=75, 2-13 20 Concentrated Loads (lb) Vert: 4=-1 42(B) 7=-460 13=-89(B) 20=41 (B) 21 =-327(B) 17=-79(B) 25=-97(B) 26=-97(B) 29=-41 (B) 30=-1 021 (F) 31 =-79(B) 32=-79(B) 33=-79(B) 34=-79(B) WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473 r— 1010312015 BEFORE USE. De sign valid for use only with MiTeke connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only, Additional temporary and permanent bracing MiTek" s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage. delivery, erection and bracing of trusses and truss systems, see ANSlITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Earcelona-A or C—TRAY T13452389 P2392ACT C11 COMMON 1 all Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10-51,31 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-A6aVp7ymFH7QOJbEeIKOLY11194myiiTlXjkqxzcgbg M 5-9-4 16-2-12 22-0-0 23-M 5-9-4 5-2-12 5-2-12 5-9-4 1-0-0 Scale = 1:39.3 4x4 6 o o F1 _2 1.5x4 3 18 19 1.5x4 31 2 17 20 7 1`2 10 9 8 3X4 3X4 3x4 3x4 3X4 7-6-3 14-5-13 22-0-0 7-6-37-6-3 6-11-11 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Ildefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) 0.07 10-13 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.58 Vert(CT) 0.18 10-13 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.20 Horz(CT) 0.04 6 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Weight: 101 to FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=940/0-8-0,6=940/0-8-0 Max Horz 2=1 15(LC 11) Max Uplift 2=11 81 (LC 12), 6=-1 81 (LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (b) or less except when shown. TOPCHORD 2-3=-1 525/468, 3-4=-1 367/470, 4-5=-1 367/470, 5-6=-1 525/468 BOTCHORD 2-110 326/11328, 8-10=-151/876, 6-8=-344/1328 WEBS 4-8=-1 57/526, 5-8=-340/203, 4-1 D=-1 57/526, 3-1 0=-340/203 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-5-3 oc purlins. BOTCHORD Rigid ceiling directly applied or 9-11-14 oc bracing. NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=15ft, B=45ft; L=24ft, eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 11-0-0, Exterior(2) 11-0-0 to 14-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=11.60 3) This truss has been designed for a 10.0 psf boftom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the boftorn chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=1 81, 6=1 81. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FIL Cert 6634 6904 Parke East Blvd. Tarnpa FIL 33610 Date: March 9,2018 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. ANNE, Design valid for use only with MiTekID connectors. This design is based only upon parameters shown, and is for an individual building component, not EJ a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall old building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FIL 36610 Job T ss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452390 P2392ACT C2 HIP 1 all Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:32 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-el7tOTzOOaFHeTAOCOsdulrAGZOehAGdGBRIMOzcgbf 4-9-4 3-0-0 1 17-2-12 22-0-0 i23-0-00LI _ 0_0 -9-41' - —"' 0 4-9-4 Z2--102 4 4-2-12 4 Scale = 1:39.1 4x4 = 48 — 4x4 3x8 3X4 = 3x4 — 4x4 = LOADING (psf) SPACING- 2-0-0 CsI. DEFL. in loc) I/def] Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.48 Vert(LL) -0.16 9-17 >999 240 MT20 -244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.73 Vert(CT) -0.34 9-17 >781 180 BCLL 0.0 Rep Stress Incr YES WB 0.18 Horz(CT) 0.04 7 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 108 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 4-4-5 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 8-8-15 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=940/0-8-0, 7=940/0-8-0 Max Horz 2=96(LC 11) Max Uplift 2=-1 81 (LC 12), 7=-1 81 (LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (11o) or less except when shown. TOPCHORD 2-3=-1 547/578, 3-4=-1 237/462, 4-5=-1 054/459, 5-6=-1 237/462, 6-7=-1 547/578 BOTCHORD 2-11 =-446/1364, 9-11 =-255/1054, 7-9=-453/1364 WEBS 3-11 =-360/226, 4-11 =-74/339, 5-9=-67/339, 6-9=-361/226 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=l 40mph (3-second gust) Vasd=1 08mph; TCDL=4.2psf; BC DL=3.Opsf; h= 1 5ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 9-0-0, Exterior(2) 9-0-0 to 13-0-0, Interion(l) 17-4-11 to 23-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=181,7=181. A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 — 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. gRegan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33,61 D Date: March 9,2018 MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq/Barcelona -A or C TRAY T13452391 P2392ACT c3 HIP Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:33 2018 Page 1 ID:ItiEL2vqrkv4uEJUYC2jFzkFng-7UhFEp_lnuN8GdlcmjNsQzOMlyjhQa7mVrBrvqzcgbe 1 1-M 0 1" 2 2 22-0-0 22102 4-0-0 4110 12 1'2 3-9-4 Scale = 1:39.1 2 3x5 = 6.00 F12 1 X4 4x4 = 3x8 4x4 4 20 21 5 22 23 6 13 24 12 11 25 10 3x8 4x4 = 1X4 11 3x8 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) Ildefl Ud TCLI _ 20.0 Plate Grip DOL 1.25 TC 0.42 Vert(LL) 0.12 11 999 240 TCDL 1 0.0 Lumber DOL 1.25 BC 0.81 Vert(CT) 0.24 11 999 180 BCLL 0.0 Rep Stress Incr NO WB 0.33 Horz(CT) 0.09 8 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD BOT CHORD 2x4 SP No.2 BOTCHORD WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1616/0-8-0,8=1616/0-8-0 Max Horz 2=-77(LC 6) Max Uplift 2=-416(LC 8), 8=-416(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 ((b) or less except when shown. TOPCHORD 2-3=-3074/796, 3-4=-2873/763, 4-5=-2564/708, 5-6=-2564/708, 6-7=-2873/763, 7-8=-3074/796 BOTCHORD 2-13=-651/2720, 11-13=-689/2898, 10-11 =-689/2898, 8-1 0=-651/2720 WEBS 3-13=-274/78, 4-13=-1 52/876, 5-13=-503/152, 5-1 0=-503/152, 6-1 0=-1 52/876, 7-10=-274/78 1 x4 -- 8 3x5 — PLATES GRIP MT20 244/190 Weight: 112 lb FT = 20% Structural wood sheathing directly applied or 3-2-7 oc, purlins. Rigid ceiling directly applied or 7-1-9 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except ot=lb) 2=416, 8=416. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 189 lb down and 204 lb up at 7-0-0, 97 lb down and 106 lb up at 9-0-12, 97 lb down and 106 lb up at 11-0-0, and 97 lb down and 106 lb up at 12-11-4, and 189 lb down and 204 lb up at 15-0-0 on top chord, and 327 lb down and 97 lb up at 7-0-0. 66 lb down at 9-0-12, 66 lb down at 11-0-0, and 66 lb down at 12-11-4, and 327 lb down and 97 Ilp up at 14-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate lncrease=1.25 Uniform Loads (pl Vert: 1-4=-60, 4-6=-60, 6-9=-60, 14-17=-20 Concentrated Loads (lb) Vert: 4=-1 42(F) 6=-1 42(F) 13=-327(F) 11 =41 (F) 5=-97(F) 1 0=-327(F) 21 =-97(F) 22=-97(F) 24=41 (F) 25=-41 (F) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 AWARNING - Verify design panitnefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111-7473 rev, 1010312015 BEFORE USE. Design valid for use only with M!TekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22314. Tampa, FL 36610 Job T ss Truss Type aty Ply Park Sq/Barcelona-A or C - TRAY T13452392EbP2392ACTC4HIP1 2 Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:34 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-bhFdR9?fYCV?tmKpKRu5zAwOyM5g9vrwkVwPRGzcgbd 1 1 30 11-0-0 14-9-0 1 6 -," 1 1_0 0 22-0-01-M 1 i _'_ 0 _81 61 1-1120-112 3-9-0 3 2-1--8 3-0-0 6 q THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 4x8 — 1.5X4 11 4 20 5 21 4x4 2X4 3X4 7X8 Scale = 1:37.9 5x8 MT1 3HS = 6X6 8X8 3XS 1 5x14 i I _M i i i ln i P. - 1 LOADING (ps TCLL 20.0 TCDL 10.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017/TP12014 CS1. TC 0.98 BC 0.69 WB 0.82 Matrix -MS DEFL.. in Vert(LL) -0.17 Vert(CT) -0.34 Horz(CT) 0.08 loc) Ildefl L/d 11 >999 240 11 >775 180 9 n/a n/a PLATES_ GRIP MT20 244/190 MT18HS 244/190 Weight: 277 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 1-4-4 oc purlins. BOTCHORD 2x6 SP DSS BOTCHORD Rigid ceiling directly applied or 9-8-1 oc bracing. WEBS 2x4 SP No.3 *Except* 4-14,5-13,6-12,7-11: 2x4 SP No.2 WEDGE Right: 2x4 SP No.3 REACTIONS. (lb/size) 9=7852/0-4-0, 2=2829/0-4-0 Max Horz 2=78(LC 7) Max Uplift 9=-2102(LC 8), 2=-775(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-5822/1545, 3-4=-5655/1541, 4-5=-7080/1962, 5-6=-7080/1962, 6-7 9793/2701, 7-8=-14154/3875, 8-9=-15433/4176 BOTCHORD 2-15=-1339/5181, 14-15=-1339/5181, 13-14=-1279/5035, 12-13=-2374/8988, 11-12=-3394/12644, 10-11=-3701/13784,9-10 3701/13784 WEBS 3-14 325/71, 4-14=-64/343, 4-13=-803/2907, 6-13=-2707/949, 6-12=-1 647/6014, 7-12=-6664/1856,7-11 1976/7224,8-11=-1329/357,8-10 261/1127 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nallsasfollows: Top chords connected as follows: 2x4 - I row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 3 rows staggered at 0-2-0 oc. This item has been Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. electronically signed and2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to sealed by ORegan, Philip, PEplyconnectionshavebeenprovidedtodistributeonlyloadsnotedas (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. using a Digital Signature. 4) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=25ft, B=45ft; L=24ft; eave=4ft; Cat. Printed copies of this 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) Lumber DOL=1.60 plate grip DOL=1.60 document are not considered 5) Provide adequate drainage to prevent water ponding. signed and sealed and the 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. signature must be verified 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide on any electronic copies. will fit between the bottom chord and any other members. Philip J. O'Regan PE No.58126 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) except Ot=lb) Wilk USA, Inc. FL Cod 6634 9=2102,2=775. 6904 Parke East Blvd. Tampa FL 33610 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 5991 lb down and 1715 lb up at Date: 16-6-8, 1187 lb down and 307 lb up at 16-11-4, and 636 lb down and 176 lb up at 18-11-4, and 1047 lb down and 274 lb up at March 9,2018 20-114 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. j"H*%1W TES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. as da, andREADNO Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall BMW building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is =ays required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek' fab ication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. . Tampa, FL 36610 Job Truss Truss Type City Ply Park Sq/Barcelona-A or C—TRAY T13452392 P2392ACT C4 HIP 1 2 Job Reference (oDt ona Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:34 2018 Page 2 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-bhFdR9?fYCV?tmKpKRu5zAwOyM5g9vrwkVwPRGzcgbd LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-60, 4-6=-60, 6-9 60, 2-9=-20 Concentrated Loads (lb) Vert: I 1=-5991(B) 10=-636(B) 17=-1047(B) 22=-1 187(B) WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473— 1010312015 BEFORE USE. Design valid for use only with MiTek(ID connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indivdual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452393 P2392ACT C5 HIP 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:35 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-3tp?fVOHJVds\Avu?tBPKWOThbmSOuW63yggyzjzcgbc 6-0-0 11-0-0 1 R 0_0 22-0-0 23-0-0 Tol 6-0-0 5-0-0 5-0-0 6-0-0 1-0-0 Scale = 1:39.1 4x8 = 19 20 48 — 3x4 1X4 11 3X4 = 3x8 = 1X4 11 3x4 = LOADING (psf) SPACING-" 2-0-0 cSI. TCLI 20.0 Plate Grip DOL 1.25 TC 0.48 TCDL 0.0 Lumber DOL 1.25 BC 0.53 BCLL 0.0 Rep Stress Incr YES WB 0.17 BCDL 10.0 Code FBC2017fTP12014 Matrix -MS LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=940/0-3-8,6=940/0-3-8 Max Horz 2=67(LC 11) Max Uplift 2 252(1_C 12), 6=-252(LC 12) FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1527/526, 3-4=-1616/614, 4-5=-1616/614, 5-6=-1527/529 BOTCHORD 2-11 368/1301, 9-11 =-367/1308, B-9=-378/1308, 6-8=-378/1301 WEBS 3-9=-1 40/455, 4-9=-327/169, 5-9 1 41/455 DEFL. in (loc) I/clefl L/d PLATES GRIP Vert(LL) -0.06 9 >999 240 MT20 2441190 Vert(CT) -0.13 11-14 >999 180 Horz(CT) 0.04 6 n/a n/a Weight: 99 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 4-0-14 oc purlins. BOTCHORD Rigid ceiling directly applied or 9-1-3 oc bracing. NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 6-0-0, Exterior(2) 6-0-0 to 20-2-15, Interior(l) 20-2-15 to 23-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=252,6=252. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Ina. Fl. Cert 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411.7473mv. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall bu ilding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS] Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Tr ss Type oty Ply Park Sq/Barcelona-A or C—TRAY T13452394 P2392ACT C6 HIP 1 1 Job Reference loot one Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:36 2018 Page I ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-X3NOsrOv4plj74TBRswZ2b?rLAlTdt5CBpPW9zcgbb 5-0-0 12-11-7 17-0-0 22-0-0 23-MM9-0-2 i I I +; 5-0-0 _1 4-0-9 5-0-0 Srale = 1:39.1 4x8 = 1X4 11 3x4 = 4X8 = Ann 71;_ J 4 18 19 20 6 44 = 2X4 4X8 = 6X6 3x5 — 2X4 11 3x6 = R, a LOADING (psf) SPACING- 2-0-0 cSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20 O Plate Grip DOL 1.25 TC 0.54 Vert(LL) 0.16 10-12 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.86 Vert(CT) 0.31 10-12 >848 180 BCLL 0.0 Rep Stress Incr NO WB 0.57 Horz(CT) 0.06 7 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MS Weight: 121 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 2-8-1 oc purlins. BOTCHORD 2x6 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied or 7-2-0 oc bracing. 7-11: 2x6 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1 371/0-3-8, 7=1 569/0-3-8 Max Horz 2=58(LC 7) Max Uplift 2=-398(LC 8), 7=-476(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2590/712, 3-4=-3500/1049, 4-5=-3500/1049, 5-6=-3785/1136, 6-7=-3051/891 BOTCHORD 2-13 575/2266, 12-13=-573/2274, 10-12=-1051/3785, 9-10=-720/2702, 7-9=-714/2677 WEBS 3-12=-478/1507, 5-12=-371/224, 6-10=-397/1339, 6-9=-101/428 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft, Cat. 11; Exp B, Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=398,7=476. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 51 lb down and 77 lb up at 13-0-12, and 51 lb down and 77 lb up at 14-3-4 on top chord, and 577 lb down and 197 lb up at 11-0-12, 36 lb down at 13-0-12, and 36 lb down at 14-3-4, and 329 lb down and 145 lb up at 16-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate Increase=1.25 Uniform Loads (Ipl Vert: 1-3=-60, 3-6=-60, 6-8=-60, 2-7=-20 Concentrated Loads (lb) Vert: 5=-51 (F) 1 0=-26(F) 20=-51 (F) 21 =-577(F) 22=-26(F) 23=-329(F) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 WARNING- Verify design parameters and READ NOTES ON`HISAND INCLUDED MITEK REFERENCE PAGE MII-7473ray. 1010312015 BEFORE USE. Design valid for use only with MiTelk(l) connectors. This design is based only upon parameters shown, and is for an individual building component. not Ell a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall KWW ibuilding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' s always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sq/Barcelona -A or C—TRAY T13452395 P2392ACT C7 HIP 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Mar 9 10:51:37 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-?Gxm4BlXr7takE2N?ZRobpYlEZ64MQNMQT932bzcgba 4-9-4 9-0-0 13-0-0 1650 4-9-4 4-2-12 4-0-0 3- 3l 4x4 = 4x8 = 14 7 44 3xB 3X4 1.5x4 Scale = 1:31.3 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) 0.14 9-12 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.65 Vert(CT) 0.29 9-12 676 180 BCLL 0.0 Rep Stress Incr YES WB 0.19 Hor7(CT) 0.02 7 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 91 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BOTCHORD REACTIONS. (lb/size) 2=713/0-3-8, 7=649/Mechanical Max Horz 2= 121 (LC 12) Max Uplift 2=-190(LC 12), 7=-162(LC 12) FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1 052/424, 3-4=-740/305, 4-5=-602/317, 5-6=-479/227, 6-7=-609/292 BOTCHORD 2-9=-440/922, 8-9=-1 53/382 WEBS 3-9=-363/232, 5-9=-1 25/362, 5-8=-288/143, 6-8=-1 97/496 Structural wood sheathing directly applied or 5-3-13 oc purlins, except end verticals. Rigid ceiling directly applied or 8-10-8 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft ' eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 9-0-0, Exterior(2) 9-0-0 to 13-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except dt=lb) 2=190,7=162. A WARNING Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473— 1010312015 BEFORE USE. Design valid for use only with MiTek& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is aKvays required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, deliv", erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.68126 MiTelk USA, Inc. Fl. Cert 6634 6904 Parke East Blvd, Tampa FL 33610 Date: March 9,2018 Nil' MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job T as Truss Type Oty Ply Park Sq/Barcelona-A or C—TRAY T13452396 P2392ACT C8 COMMON 4 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:37 2018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-?Gxm4BlXr7takE2N?ZRobpY3dZ6jMJDMQT932bzcgba 5-9-4 11-0-0 16-5-0 5-9-4 5-2-12 5-5-0 5x6 = 3X4 6 3X4 3x4 = Scale = 1:36.4 LOADING (psfi SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.38 Vert(LL) 0.11 6-7 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.67 Vert(CT) 0.20 6-7 988 180 BCLL 0.0 Rep Stress Incr YES WEI 0.61 Horz(CT) 0.02 6 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 83 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BOTCHORD REACTIONS. (lb/size) 2=713/0-3-8, 6=649/Mechanical Max Horz 2=1 21 (LC 12) Max Uplift 2=-190(LC 12),6=-162(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1019/321, 3-4=-797/282 BOTCHORD 2-7=-331/883, 6-7=-1 38/426 WEBS 3-7=-359/209, 4-7=-1 16/540, 4-6=-562/180 Structural wood sheathing directly applied or 5-4-11 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft, eave=4ft; Cat. 11 Exp B; Encl., GCpj=0.18; MWFRS (directional) and C-C Exterion(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 11-0-0, Exterior(2) 11-0-0 to 1:0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) except at=lb) 2=1 90, 6=1 62. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE N0.58126 M!Tak USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FIL 33,610 Date: March 9.2018 AWARNING - Verify design P ... meters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(E) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is al ays required for stab ility and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabricatio n, storag e, cl el ivery, a recti on a nd bra ci ng of tnu sses and t russ system s, see ANSI/TPI1 Quality Criteria, DSB-89 and BCS] Building Component 6904 Parke East Blvd. Safety Infonmation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452397 P2392ACT ci JACK 4 Job Reference (optional) Mid-Fiorida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:38 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-TSV8HW29cQ?RMOdaZGyl7O5HfzbA5vZVe7uca2zcgbZ 2 0-11-4 1 1-12 0- -4 Scale = 1:13.8 1.5x4 11 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.17 Vert(LL) -0.00 5 >999 240 MT20 - 244/190 TCDL 10.0 Cumber DOL 1.25 BC 0.08 Vert(CT) -0.00 5 >999 180 BCLL 0.0 Rep Stress Incr YES WEI 0.00 Horz(CT) -0.01 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MR Weight: 7 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 1-0-0 oc purlins, BOTCHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=160/0-4-0,3=-24/Mechanical, 4=-I/Mechanical Max Horz 5=69(LC 12) Max Uplift 5=-25(LC 8), 3=-24(LC 1), 4=-45(LC 12) Max Grav 5=160(LC 1), 3=10(LC 10), 4=31(LC 10) FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) 5, 3, 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc, FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 — 1010312015 BEFORE USE. Design valid for use only with MiTek(g) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Bet ibuilding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fa b rication, storage, delivery, ere ct ion and b raci n g of I ru sses a nd truss system s, see ANSIITPI1 Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FIL 36610 Job Truss Truss Type Qty Ply Park Sq/Barceiona-A or C—TRAY T13452398 P2392ACT Cil JACK 22 Job Reference (optional) Mid-FlOnda Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Mar 9 10:51:39 2018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-xe3WUs3nNk7l—YCm6—UGgEdTzNyWqMpftneA6UzcgbY 1-0-0 1-0-0 2x4 = LOADING (psft SPACING. 2-0-0 cSI. DEFL. in loc) I/clefl L/d 20.0 Plate Grip DOL 1.25 TC 0.07 Vert(LL) 0.00 5 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.01 Vert(CT) 0.00 5 999 180 BCLL 0.0 Rep Stress Incr YES WEj 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=10/Mechanical, 2=130/0-3-8, 4=-O/Mechanical Max Horz 2=42(LC 12) Max Uplift 3=-3(LC 9), 2=-73(LC 12) Max Grav 3=11(LC 17), 2=130(LC 1), 4=12(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. c? Scale = 1:7.0 PLATES GRIP MT20 - 244/190 Weight: 5 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft, L=24ft, eave=4ft, Cat. 11; Exp 6; Encl., GCpi=0.18 ' MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FIL 33,610 Date: March 9,2018 AWARNING - Verify design parameters andREADNOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTelk(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall lei" building design. Bracing ind cated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job T ss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452399 P2392ACT CJ3 JACK 13 Job Reference (ontiona ) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries Inc. Fri Mar 9 10:51:39 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-xe3WUs3nNk7l—YCm6—UGgEdTcNxVqMpftneA6UzcgbY 1-0-0 3-0-0 2x4 = LOADING (psf) SPACING- 2-0-0 CS1. TCLI_ 20.0 Plate Grip DOL 1.25 TC 0.09 TCDL 10.0 Lumber DOL 1.25 BC 0.08 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017ITP12014 Matnx-MP LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=71 /Mechanical, 2=188/0-3-8, 4=36/Mechanical Max Horz 2=74(LC 12) Max Uplift 3=-34(LC 12), 2=-66(LC 12) Max Grav 3=71(LC 1), 2=188(LC 1), 4=52(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (11b) or less except when shown. Scale: V=l' DEFL. in (loc) I/defl Ud PLATES GRIP Vert(LL) -0.00 4-7 >999 240 MT20 244/190 Vert(CT) -0.01 4-7 >999 180 Horz(CT) -0.00 3 n/a n/a Weight: 11 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft, B=45ft, L=24ft, eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 2-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) 3, 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No,58126 MiTak USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekS connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Nil' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job T ss Truss Type Qty Ply Park Scl/Barcelona-A or C_TRAY T13452400 P2392ACT CJ3A JACK 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 2x4 — 3-0-0 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:40 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-PrcuiC3Q82G9bhnygh?VDRAeAnHQZp3o6QNjewzcgbX Scale: V=1' LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.10 Vert(LL) 0.01 3-6 >999 : 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.10 Vert(CT) -0.01 3-6 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 10 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) I =1 18/Mechanical, 2=76/Mechanical, 3=42/Mechanical Max Horz 1=49(LC 12) Max Uplift 1=-15(LC 12),2=-38(LC 12),3=-3(LC 12) Max Grav 1 =1 18(LC 1), 2=76(LC 1), 3=54(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (11b) or less except when shown. NOTIES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft, L=24ft, eave=4ft, Cat. 11; Exio B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone,C-C for members and forces & IVIWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 3. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Inc. I'L Cert6634 6904 Parke East Blvd. Tampa FL 3361, 0 Date: March 9,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev, 1010312015 BEFORE USE. Design valid for use only with M!TekOD connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall Bel' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job T ss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452401 P2392ACT CJ3T SPECIAL 4 Job Reference (optional) Mid -Florida Lumber, Bartow, FIL. c? 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:41 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-ulAGvY42uLOODrM9EPWklfjoNBb2lGxyL47GBMzcgbW 2-1-12 -3 M-01-1-0 i '_ 1 1 , , 1:6-1 2-1-12 _8 Scale: 1 "= 1' LOADING (pso SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=189/0-3-8,5=115/Mechanical Max Horz 2=84(LC 12) Max Uplift 2=-64(LC 12), 5=51 (LC 12) cs c? 2x4 = CS1. DEFL. in (loc) I/defl, L/d PLATES - GRIP TC 0.14 Vert(LL) -0.01 7 >999 240 MT20 244/190 BC 0.20 Vert(CT) -0.01 7 >999 180 WB 0.02 Horz(CT) 0.01 5 n/a n/a Matrix -MP Weight: 13 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft, Cat. 11; Exp B, Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interjor(l) 2-0-0 to 3-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 Walk USA, Inc. F L Cert 6634 6904 Parke East Blvd. Tampa FL 3361D Date: March 9,2018 AWARNING Verify design parameters and READ NOTES ON THIS AND INCLUDED MIrEK REFERENCE PAGE MII-7473 r— 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall Rol' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq/Barcelona-A or C—TRAY P2392ACT CJ5 JACK 10 Job Referen Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:41 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng_ulAGvY42uLOODrM9EPWklfjlVBa4lGlyL47GBMzcgbW 5-0-0 1_'_0 5-0-0 2x4 LOADING (pso SPACING- 2-0-0 CS1. JCLL 20.0 Plate Grip DOL 1.25 TC 0.32 TCDL 10.0 Lumber DOL 1.25 BC 0.26 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=127/Mechanical, 2=264/0-3-8, 4=64/Mechanical Max Horz 2=108(LC 12) Max Uplift 3=-64(LC 12),2=-73(LC 12) Max Grav 3=127(LC 1), 2=264(LC 1), 4=91(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale= 1: 17.0 DEFL. in (loc) I/defl L/d PLATES GRIP Vert(LL) 0.04 4-7 999 240 MT20 244/190 Vert(CT) -0.06 4-7 >988 - 180 Horz(CT) -0.00 3 n/a n/a Weight: 18 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=25ft, B=45ft, L=24ft; eave=4ft, Cat. 11, Exp B, Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 4-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Dpsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL,Cert 6634 6904 Parke East Blvd. Tampa FL 3361D Date: March 9.2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekS connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Del' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Sure 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C_TRAYIqjolb T13452403 P2392ACT CJ5T SPECIAL 4 1 Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:42 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-MDkf7u5gffWtr?xLo6lzisFuRawNlj?5Zks,qjpzcgbV 2-1-12 2 5-0-0 2-1-12 6_ I1-0-0 1' 2 2-8-8 Scale = 1: 17.0 2x4 LOADING (psf]i SPACING- 2_D_0 cSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.50 TCDL 10.0 Lumber DOL 1.25 Bc 0.19 BCILL 0.0 Rep Stress Incr YES VVB 0.04 BCDL 10.0 Code FBC2017/TP]2014 Matrix -MP LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. lb/size) 4=165/Mechanical, 2=267/0-3-8, 5=29/Mechanical Max Horz 2=108(LC 12) Max Uplift 4=-71 (LC 12), 2=-72(LC 12) Max Grav 4=165(LC 1), 2=267(LC 1), 5=59(LC 3) DEFL. in floc) I/defl L/d PLATES GRIP Vert(LL) 0.11 6 >540 240 MT20 244/190 Vert(CT) -0.14 6 >421 180 Horz(CT) 0.07 5 n/a n1a FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. 17 Weight: 19 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 4-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc, FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9.2018 WARNING - Verifydesig. parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473— 1010312015 BEFORE USE. Design valid for use only with MiTek& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall tag, building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fab ncation, storage, delive ry, erect ion a n d b raci n g of truss as and tru ss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job T ss Truss Type Qty Park Sq/Barcelona-A or C—TRAYPly T13452404 P2392ACT of MONO HIP 2 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:43 2018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-qQIIKE6lQzejS9VVXLqYCq4olQ_Bxmz—EoOcNFFzcgbU 1_0_0 7-4-14 14-3-4 1 -51 O 1-0-0 7-4-14 6-10-6 _1_ 4x8 = I.5X4 11 Scale = 1:43.1 3x4 IX4 11 3x4 3x4 = 7-4-14 14-3-4 LOADING (ps TCLL 20.0 TCDL 10.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TP12014 cSI. TC 0.61 BC 0.56 WEI 0.88 Matrix -MS DEFL in Vert(LL) -0.07 Vert(CT) -0.17 Horz(CT) 0.02 loc) I/def! L/d 8-11 >999 240 8-11 >999 180 6 n/a n/a PLATES-- GRIP MT20 -244/190 Weight: 101 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 5-3-11 oc purlins, BOTCHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 9-7-14 oc bracing. REACTIONS. (lb/size) 6=649/Mechanical, 2=713/0-3-8 Max Horz 2=264(LC 12) Max Uplift 6=-207(LC 12),2=-146(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-970/159, 3-4=-295/22 BOTCHORD 2-8=-354/817, 7-8=-354/817 WEBS 3-8=0/323, 3-7=-737/309, 4-7=-98/477, 4-6=-654/311 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft, L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interion(l) 2-0-0 to 14-3-4, Exterior(2) 14-3-4 to 16-3-4 zone,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. This item has been 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) electronically signed and6=207,2=146. sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 Ii USA, Ina. F L Celt 6634 6904 Parke East Blvd, Tampa FIL 33610 Date: March 9,2018 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE MII-7473 r— 1010312015 BEFORE USE. Design valid for use only with MiTekS) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fa bricatio n, storag e, delive ry, erect ion and bra cing of truss es and tru ss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Sulte M2, Alexandria, VA22314. Tampa, FL 36610 Job T ss T uss Type Qty Ply Park Sq/Barcelona-A or C_TRAY T13452405 P2392ACT D1T SPECIAL 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 2-3-8 6-0-8 5x5 --- 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:43 2018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2iFzkFng-qQIIKE610zejS9VVXLqYCq4oxL_6Fm7fEoOcNFFzcgbU M-8 2-0-8 Scale = 1:29.5 6 9 4x8 2X4 1.5x4 2.4 4x8 1.5x4 11 2X4 2:1 174 O 6' 2-1-1 O_' Plate Offsets (X,Y)- [2:0-2-9,0-2-21, [4:0-2-1,0-2-61 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES, GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 1.00 Vert(LL) -0.18 6-13 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.86 Vert(CT) -0.36 6-13 >536 180 BCLL 0.0 Rep Stress Incr YES WB 0.20 Horz(CT) 0.27 5 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Weight: 83 lb FT 20% LUMBER- BRACING- TOPCHORD 2x6 SP No.1 *Except* TOPCHORD Structural wood sheathing directly applied. 3-5:2x6 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. BOTCHORD 2x4 SP No.2 *Except* 7-8,9-10: 2x4 SP No.3, 2-4: 2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=667/0-3-8, 5=654/Mechanical Max Horz 1 =78(LC 11) Max Uplift 1=-148(LC 12), 5=-151(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-292/113, 2-3=-1227/407, 3-4=-1227/407, 4-5=-285/117 BOTCHORD 2-6=-255/1097, 4-6=-255/1097 WEBS 3-6=-1 14/529 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf; h=25ft; B=45ft; L=24ft, eave=4ft, Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-3-0, Interior(l) 3-3-0 to 8-4-0, Exterior(2) 8-4-0 to 11-4-0 zone;C-C for members and forces & MWFRS for reactions shown ' Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSIfTPI I angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1 DO lb uplift at joint(s) except Ot=lb) I =1 48. 5=1 51. A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse wilh possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Ragan PE No.58126 MiTsk USA, Ina. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 Nit MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452406 P2392ACT D2 MONO HIP 2 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Mar 9 10:51:44 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-IcsPYa7wBGma4J4kvX3RNHLE?OZ2vuYOl2LxnhzcgbT 1-D-0 6-4-14 12-3-4 16-5-0 1_0_0 6-4-14 5-10-6 4-1-12 4x8 = 14 1,5x4 11 Scale = 1:38.5 3X4 1 x4 3x4 3X4 LOADING (psf), SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES_ GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.43 Vert(LL) 0.04 8-11 999 240 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.44 Vert(CT) 0.11 8-11 999 180 BCLL 0.0 Rep Stress Incr YES WIB 0.61 Horz(CT) 0.02 6 n/a n/a BCDL 10.0 Code FBC2017/TP]2014 Matrix -MS Weight: 95 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BOTCHORD REACTIONS. (lb/size) 2=713/0-3-8,6=649/Mechanical Max Horz 2=231 (LC 12) Max Uplift 2=1 59(LC 12), 6=-1 93(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1023/231, 3-4=-455/109 BOTCHORD 2-8=-393/872, 7-8=-393/872, 6-7=-1 56/335 WEBS 3-8=0/273, 3-7=-620/271, 4-7=-92/428, 4-6=-608/284 Structural wood sheathing directly applied or 5-5-5 oc purlins, except end verticals. Rigid ceiling directly applied or 9-3-6 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 6=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 12-3-4, Exterior(2) 12-3-4 to 16-3-4 zone,C-C for members and forces & M\AIFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=1 59, 6=1 93. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke EaSt Bltid. Tampa FL 3361 D Date: March 9,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED VITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekID connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek' is al.ays required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452407 P2392ACT D2T SPECIAL 2 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 2-3-8 c? 8-4-0 6-0-8 5x5 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:45 2018 Page 1 ID:ItiEi_2vqrkv4uEJUYC2jFzkFng-moQnlw7YyauRiTfwTFagwVti3ooZE16XFi5UK8zcgbS 6-0-8 2-3-8 2x4 Scale = 1:30.6 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate G . rip DOL 1.25 TC 0.86 Vert(LL) -0.18 6-16 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.87 Vert(CT) -0.38 6-13 >523 180 BCLL 0.0 Rep Stress Incr YES WB 0.20 Horz(CT) 0.30 5 n/a n/a BCDL 10.0 Code FBC2017rTP12014 Matrix -MS Weight: 84 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x6 SP No.1 TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOTCHORD 2x4 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 7-8,9-10: 2x4 SP No.3, 2-4: 2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1 =676/0-3-8, 5=663/0-3-8 Max Horz 1 =-78(LC 10) Max Uplift 1=-150(LC 12), 5=-153(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (1b) or less except when shown. TOPCHORD 1-2=-297/118, 2-3=-1 264/415, 3-4=-1 265/414, 4-5=-288/120 BOTCHORD 2-6=-259/1131, 4-6=-25911131 WEBS 3-6=-115/538 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140rnph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-3-0, Interior(l) 3-3-0 to 8-4-0, Exterior(2) B-4-0 to 11-4-0 zone;C-C for members and forces & M\AIFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 1, 5 considers parallel to grain value using ANSI/TP1 I angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 1=150, 5=153. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MR-7473 rev. 1010312015 BEFORE USE. Design valid for use only with M!TekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB.89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTolk USA, Inc. FIL Cert6634 6904 Parke East 131A. Tampa FL 33610 Date: March 9,2018 MiTek' 6904 Parke East Blvd. Tampa, FIL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C TRAY T13452408 P2392ACT D3 MONO HIP 2 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. b.iiu s bep i* zu I I vi ieK mausines, Inc. rn [viar iu:o rffo u io rage I ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-E_9yF8AjuOlJcE6ly6vSiQZpCGUzM2hUMqlsazcgbR 5-4-14 10-3-4 16-5-0 1_0_0 5-4-14 4-10-6 6-1-12 3 4x8 = 4 14 Scale = 1:33.2 2x4 15 16 5 b 3x4 1 X4 3x4 3x4 — LOADING (psf) SPACING- 2-0-0 cSI. DEFL. in loc) I/defl L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.48 Vert(LL) 0.04 6-7 999 240 TCDL 1 0.0 Lumber DOL 1.25 BC 0.37 Vert(CT) 0.08 6-7 999 180 BCLL 0.0 Rep Stress Incr YES WEI 0.74 Hor7(CT) 0.02 6 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BOTCHORD REACTIONS. (lb/size) 2=713/0-3-8, 6=649/Mechanical Max Horz 2=198(LC 12) Max Uplift 2=-171(LC 12), 6=-192(LC 9) FORCES. (1b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1069/296, 3-4=-622/192 BOTCHORD 2-8=-424/919, 7-8=-424/919, 6-7=-224/503 WEBS 3-7=-484/231, 4-7=-71/409, 4-6=-640/286 PLATES GRIP MT20 244/190 Weight: 90 lb FT = 20% Structural wood sheathing directly applied or 5-5-2 oc purlins, except end verticals. Rigid ceiling directly applied or 9-0-2 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf, h=25ft; B=45ft, L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 10-3-4, Exterior(2) 10-3-4 to 14-6-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=171,6=192. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Inc. FL Cort 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEM11.7473 — 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability ofdesign parameters and properly incorporate this design into the overall NOR' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Addilional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C TRAY T13452409 P2392ACT 133T SPECIAL 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 a Sep 15 2017 MiTelk Industries, Inc. Fri Mar 9 10:51:47 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-iBXYAb9pUB89xmplafd8.?W7d5bVkivrqjOabOOzcgbQ 0 i -6-: 14-4-8 16-8-0 2-10-0 2-3-82-3-: 110 1- 0 5x8 = c? T6 21 6x6 = 2X4 11 Scale = 1:28.5 LOADING (psf) TCLL 20.0 TCDL 10.0 BCLI_ 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017/TP]2014 CS1. TC 0.95 BC 0.82 W3 0.38 Matrix -MS DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) - I/defl L/d 0.21 10-17 >944 240 0.43 10-17 >455 180 0.37 8 n/a n/a PLATES- GRIP MT20 244/190 Weight: 96 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x6 SP DSS *Except* TOPCHORD Structural wood sheathing directly applied or 2-6-7 oc purlins. 4-5: 2x6 SP No.2 BOTCHORD Rigid ceiling directly applied or 9-7-3 oc bracing. BOTCHORD 2x4 SID No.2 *Except* 11-12,13-14: 2x4 SP No.3, 2-7: 2x6 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=1 133/0-3-8, 8=1 119/0-3-8 Max Horz 1 =66(LC 7) Max Uplift 1 =-319(LC 8), 8=-323(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-499/157, 2-3=-3354/1009, 3-4=-2784/860, 4-5=-2508/796, 5-6=-2799/866, 6-7=-3344/1014, 7-8=-492/159 BOTCHORD 2-10=-906/3251, 9-10=-675/2488, 7-9=-911/3232 WEBS 4-10=-241/1001, 5-9=-245/998, 3-10=-947/283, 6-9=-903/282 NOTIES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf ' h=25ft; B=45ft; L=24ft; eave=4ft, Cat. 11; Exp B; Encl., GCpi=0.181 MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide This item has been will fit between the bottom chord and any other members. electronically signed and6) Bearing at joint(s) 1, 8 considers parallel to grain value using ANSI1TP1 1 angle to grain formula. Building designer should verify sealed by ORegan, Philip, PEcapacityofbearingsurface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) using a Digital Signature. 1=319,8=323. Printed copies of this 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 149 lb down and 171 lb up at document are not considered 7-0-0, and 96 lb down and 102 lb up at 8-4-0, and 149 lb down and 171 lb up at 9-8-0 on top chord, and 291 lb down and 108 lb up signed and sealed and the at 7-0-0, and 59 lb down at 8-4-0, and 291 lb down and 108 lb up at 9-7-4 on bottom chord. The design/selection of such signature must be verifiedconnectiondevice(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). On any electronic copies. Philip J. O'Regan PE Ko.58126 LOAD CASE(S) Standard MiTek USA, Inc. FL Cert 6634 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 6904 Parke East Blvd. Tampa FL 33610 Uniform Loads (plf) Date: Vert: 1-16=-82, 4-16=-60, 4-5=-60, 5-7=-60, 7-8=-82, 15-18=-20 March 9,2018 tWMfl4IR(9_P'a.RP'3_i'.parametexs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev, 1010312015 BEFORE USE. Design valid for use only with MiTek(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPIl Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Truss Truss Type Qty Ply Park Scl/Barcelona -A or C—TRAY T13452409 D3T SPECIAL 1 1 Job Reference (optional) Mid -Florida Lumber. Bartow, FL. LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 4=-1 02(F) 5=-1 02(F) 1 0=-291 (F) 9=-291 (F) 21 =-96(F) 22=-29(F) 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:47 2018 Page 2 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-iBXYAb9pUB89xmplafd8?wzd5bVkivrqjOabOOzcgbQ WARNING - Verify design parameters and READ NOrES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473n., 10/03/205 BEFORE USE. Design valid for use only with MiTelkO connectors. This design is based only upon parameters shown, and is for an individual building component, not a ystem. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overalltrusss M Re k' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible persona[ injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq[Barcelona-A or C — TRAY T13452410 P2392ACT D4 MONO HIP 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 1-M 4-4-14 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Mar 9 10:51:47 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-!BXYAb9pUB89xmplafd8?wzmzbX9iugqjOabOOzcgbQ 3-10-6 4-0-14 44 4 3X4 13 5 14 4-0-14 Scale = 1:29.2 1.5X4 6 3x4 = US = 3x4 = psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/dLOADING TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) 0.09 7-8 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.67 Vert(CT) 0.18 7-8 999 180 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(CT) 0.02 7 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BOTCHORD REACTIONS. (lb/size) 2=713/0-3-8, 7=649/Mechanical Max Horz 2=164(LC 12) Max Uplift 2=-181(LC 12), 7=-208(LC 9) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (b) or less except when shown. TOP CHORD 2-3=-1 08 1 /367, 3-4=-802/256, 4-5=-665/269 BOTCHORD 2-8=-460/948, 7-8=-204/468 WEBS 3-8=-324/215, 5-8=-95/316, 5-7=-663/297 PLATES GRIP MT20 244/190 Weight: 86 lb FT = 20% Structural wood sheathing directly applied or 5-4-11 oc purlins, except end verticals. Rigid ceiling directly applied or 8-8-2 oc bracing. NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf ' h=25ft; B=45ft; L=24ft; eave=4ft Cat. 11; Exp B, Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 8-3-4, Exterior(2) 8-3- to 12-4-2 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=181,7=208. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 r— 1010312015 BEFORE USE. Design valid for use only with MiTek0connectors. This design is based only upon parameters shown, and is for an individual building component, not F=;R E9 a t russ system. Seto re use, the bu ilding designer must verify the a pplicability of cl e sign pa ra meters a nd p roperly inco rporate th i s design into I he overall gym building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type aty Ply Park Sci/Barcelona-A or C TRAY T13452411 P2392ACT D5 COMMON 3 Job Reference (optional) Mid -Florida Lumber, Barlow, FL. 1-M U4 4-5-4 B-4-0 3-10-12 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Mar 9 10:51:48 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-AN5wNxARFVGDZwOV8N8NX7Vxd?tORPA_ygJ8xSzcgbP 4x4 = 3x8 = 3-10-12 4-24 Scale = 1:30.2 3x4 6 LOADING (psf) TCLL 20.0 TCDIL 10.0 BCLL 0.0 BCDIL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC201171TPI20114 CS1. TC 0.33 BC 0.63 WB 0.18 Matrix -MS DEFL. in Vert(LIL) -0.08 Vert(CT) -0.17 Horz(CT) 0.02 loc) I/defl L/d 7-13 >999 240 7-13 >999 180 6 n/a n/a PLATES GRIP MT20 244/190 Weight: 72 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 5-4-3 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WE B S 2x4 SP No.3 REACTIONS. (lb/size) 6=655/Mechanical, 2=718/0-3-8 Max Horz 2=88(LC 11) Max Uplift 6=-155(LC 12), 2 200(1_C 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (11b) or less except when shown. TOPCHORD 2-3=-1091/381, 3-4=-817/289,4-5=-814/301, 5-6=-1077/387 BOTCHORD 2-7=-299/956, 6-7=-286/924 WEBS 4-7=-126/482, 5-7 297/11811, 3-7=-328/191 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=25ft; B=45ft, L=24ft, eave=4ft, Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interion(l) 2-0-0 to 8-4-0, Exterjor(2) 8-4-0 to 11-4-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=11.60 plate grip DOL=11.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except ot=lb) This item has been 6=155,2=200. electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. Fl. Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. &ARKDesignvalidforuseonlywithMiTekVconnectors. This design is based only upon parameters shown, and is for an individual building component, not FPPR H a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall sifta building design. Bracing indicated is to prevent buckling of indimclual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and 10 prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N Lee Street, S0e 312, Alexandra, VA 22314. Tampa, FL 36610 Job T ss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452412 P2392ACT El HIP 1 Job Reference (optional) Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. I'd Mar 9 10:51:49 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-fZflbHA3OpOtA4zh!4fc4L26zPGNAtO7AK3hTvzcgbO 5-0-0 11-0-0 1 01 5-M 0 1 5-0-0 q1 3X4 = LOADING (ps SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 1 0.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017TTP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 5=624/Mechanical, 2=690/0-3-8 Max Horz 2=57(LC 7) Max Uplift 5=-160(LC 8), 2=-207(LC 8) 4X4 = 44 — PX111111111121 Scale = 1:20.3 3x4 = r CS1. DEFL. in (loc) I/defi Lid PLATES GRIP TC 0.35 Vert(LL) -0.04 6-10 >999 240 MT20 .. 244/190 BC 0.43 Verl(CT) -0.07 6-10 >999 180 WEI 0.08 Horz(CT) 0.01 5 n/a n/a Matrix -MS Weight: 43 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 5-3-15 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1037/276, 3-4=-883/275, 4-5=-1024/275 BOTCHORD 2-7=-191/874,6-7=-190/883,5-6=-192/875 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuit=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 5=160,2=207. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 170 lb down and 179 lb up at 5-0-0, and 170 lb down and 179 lb up at 6-0-0 on top chord, and 86 lb down at 5-0-0, and 86 lb down at 5-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 4-5=-60, 8-11 =-20 Concentrated Loads (lb) Vert: 3 123fl 4=-123(F) 7=-64(F) 6=-64(F) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FIL 3361D Date: March 9,2018 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall ibuilding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and pernnanent bracing MiTek' s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabricalion, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPll Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate lnstlule, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply Park SqfBarcelona-A or C—TRAY T13452413 P2392ACT F1 ROOFTRUSS 3 Job Reference (optional) vio-t-ionaa Lumber 0-1-8 H 1 1-3-0 banow. t-L. i 1-11-12 3x3 3x3 = 3x6 FP = 4x8 2 3 4 5 8'1 3o s 6ep 15 2017 MtTeK Industries, Inc. Fn Mar 9 10:51:52 2018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-38LRDJDxJkmSiXiGNDCKizgWacAtN6rZtIHM4EzcgbL 1 2-0-0 3x4 3x4 = 1.3 3x3 3x3 3x3 6 7 8 9 10 11 Srale = 1:40.1 46 12 27 26 25 24 23 22 21 20 19 18 17 16 is 14 13 1 X3 11 3X3 = lx3 11 1 X3 11 3X3 = 3X3 11 4x5 3X4 3x4 1X3 11 3x3 = 3x3 4X5 = 3X3 11 3x6 FP Z-7-4 15-0-8 23-11-12 7-74 7-5-4 8-0-0 Plate Offsets (X,Y)— 19.0-1-8.Edgel LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.78 Vert(LL) 0.20 17-18 956 360 MT20 244/190 TCIDL 10.0 Lumber DOL 1.00 BC 0.95 Vert(CT) 0.28 17-18 704 240 BCLL 0.0 Rep Stress Incr YES WB 0.59 Horz(CT) 0.04 13 n/a n/a BCDL 5.0 Code FBC2017ITP12014 Matrix-S Weiqht: 123 lb FT = 20%F. 11 %E LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) TOPCHORD BOTCHORD 2x4 SP No.2(flat) *Except* 16-27, 2x4 SP No. 1 D(flat) BOTCHORD WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 27=287/0-8-0.13=839/0-3-8,22=1477/0-8-0 Max Uplift 27=-1 (LC 4) Max Grav 27=366(LC 3), 13=853(LC 7), 22=1479(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-27=-365/0, 12-13=-847/0,1-2=-273/30, 2-3=-493/174, 3-5=-128/461, 5-6=-397/0, 6-7=-1721/0,7-8=-2660/0,8-9=-2660/0,9-10=-2613/0,10-11=-2034/0,11-12=-842/0 BOTCHORD 25-26=-174/493, 24-25=-1741493, 23-24=-174/493, 22-23=-845/0, 21-22=-845/0, 20-21=0/1212,19-20=0/2245,18-19=0/2660,17-18=0/2660,15-17=0/2466,14-15=0/1584 WEBS 1-26=-40/370,2-26=-300/197,5-23=0/557,3-23=-699/0,12-14=011121,5-21=0/1237, 11-14=-1032/0,6-21=-1144/0,11-15=0/626,6-20=0/749,10-15=-600/0,7-20=-782/0, 10-17=0/288, 7-19=0/742, 9-17=-289/171, B-19=-303/0, 5-22=-1432/0 Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 2-2-0 oc bracing. NOTIES- 1) Unbalanced floor live loads have been considered for this design. 2) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10cl (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.68126 MiTok USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekS connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Nit building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek" fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Surte 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sci/Barcelona-A or C—TRAY T13452414 P2392ACT F2 ROOFTRUSS 5 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:57 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-Q68KGOH47GPk8JaDAmoVPlNQMdwx2NIJOa?7[RzcgbG 0-1-8 H 1 1-3-0 1-11-12 1-3-0 Scale = 1:38.8 3x3 1x3 1x3 3x3 1 2 9 8 27 26 25 1 X3 11 3X3 = IX3 IX3 11 3X3 = 3x6 MT20HS FP 4x6 3x4 3x3 = 1x3 11 3x3 3x3 3x3 46 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x3 3x6 4x5 3x4 3x3 1 X3 3x6 MT20HS FP 4X4 = 3x3 3x3 = 3x3 9 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0, Plate Grip DOL 1.00 TC 0.58 Vert(LL) , -0.15 18-19- >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.76 Vert(CT) -0.21 18-19 >895 240 MT20HS 187/143 BCLIL 0.0 Rep Stress Incr YES WEI 0.57 Horz(CT) 0.04 14 n/a n/a BCDL 5.0 Code FBC2017/TP12014 Matrix-S Weight: 121 lb FT = 20%F, 11 %E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No. 1 (flat) *Except* except end verticals. 14-17: 2x4 SP No.2(flat) BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 27=295/0-8-0,14=799/0-3-8,23=1427/0-8-0 Max Uplift 27=-1 (LC 4) Max Grav 27=375(LC 3), 14=81 1 (LC 7), 23=1 436(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (D) or less except when shown. TOPCHORD 1-27=-375/0, 13-14=-805/0, 1-2=-283/35, 2-3=-511/173, 3-5=-511/173, 5-6=0/844, 6-7=-375/0, 7-8=-1 609/0, B-9=-2415/0, 9-1 0=-2415/0, 10-11 =-2390/0, 11-12=-1 900/0, 12-13=-794/0 BOTCHORD 25-26=-1 73/511, 24-25=-1 73/511, 23-24=-459/222, 22-23=-844/0, 21-22=0/1 134, 20-21=0/2087, 19-20=0/2415, 18-19=0/2415, 16-18=0/2286, 15-16=0/1493 WEBS 6-23=-1038/0, 1-26=-471385, 5-23=-641/0, 2-26=-309/188, 5-24=01608, 3-24=-292/0, 13-15=0/1057, 6-22=0/1206,12-15=-972/0, 7-22=-1092/0, 12-16=0/565, 7-21=0/697, 11-16=-537/0,8-21=-709/0,8-20=0/611 NOTES- 1) Unbalanced floor live loads have been considered for this design, 2) All plates are MT20 plates unless otherwise indicated. 3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1 lb uplift at joint 27. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131"X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J, O'Regan PE No.58126 Walk USA, Inc. FIL Cott 6634 6904 Parke East Blvd. Tarnpa FIL 3361 a Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mli-7473 rev 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPl1 Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barrelona-A or C—TRAY T1345241 P2392ACT F3 GABLE 1 at) Mid -Florida Lumber, Bartow, FL. 0-48 1 2 41 42 41 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:58 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-uliiUMHivaXbIS9QkTJkxEv ilRznxWSFEkgHtzcgbF Scale = 1:37.8 3x3 11 3x6 FP — 3x3 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 3x3 11 3x6 FP 3x3 11 11-5-4 12-9-4 1 :10-94 i 2-1-4 M-4 4 1 741 -51 4ll9- 1 10 1N 8 12: 1TI44.Z 1T69-4 1 18-' -64 19_5_-4 i 2'P'_,r 22-1. N-4Zo '_Z 1 -1 1- -0V 6- 6- 12' 4: 1: 0 Vlt 1+41-..12 1- 10 Z7 T-4 T4o Z4 0-54 LOADING (ps: SPACING- 2-0-0 CS1. DEFL. in loc) I/clefl Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.10 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr NO W13 0.06 Horz(CT) 0.00 22 n/a n/a BCDL 5.0 Code FBC2017ITP12014 Matrix-R Weight: 104 lb FT = 20%F, 11 %E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3(flat) REACTIONS. All bearings 22-10-8. lb) - Max Grav All reactions 250 lb or less at joint(s) 42, 22, 31, 32, 34, 35, 37, 39, 40, 41, 30, 29, 28, 27, 26, 25, 24, 23, 38 except 36=580(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 7-36=-576/0 NOTES- 1) All plates are 1x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 22-42=-10, 1-21=-100 Concentrated Loads (lb) Vert: 7 552 This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev, 1010312015 BEFORE USE. Design valid for use only with MTek(S) c nnoctons, This design is based only upon parameters shown, and is for an individual building component, not a tru ss system. Before use, th a buildingodesigner must verify the applicability of design parameters and properly incorporate this design into the overall Bel' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* s atways required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, sea ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Surte 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply Park Sq/Barcelona-A or C_TRAY T13452416 Job P2392ACT F4 ROOFTRUSS 2 1 Reference (optional) Mici-t-loritta Lumber, t3arlow, FL. 0-1-8 H 1 1-3-0 05 1x3 1x3 I 7 6 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:59 2018 Page 1 ID:ItjEj_2vqrkv4uEJUYC2jFzkFng-MVG4hilKftfSNckcHBrzUSSiDRbKWDgbUuUDpKzcgbE i 2-1-8 Scale = 1 36.5 3X5 44 3x5 3x5 = 1x3 11 3x3 3x3 = 3x6 MT20HS FP 2 3 4 5 6 7 8 9 4x4 5x6 10 11 2X4 11 5x6 4x4 3x8 MT18HS FP 3X4 1X3 11 3x3 3X4 = 1X3 11 4x4 5x6 = 3x3 1x3 11 3x4 = LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Lid TCLL 40.0 Plate Grip DOL 1.00 TC 0.88 Vert(LL) -0.45 18 >575 360 TCDL 10.0 Lumber DOL 1.00 BC 0.77 Vert(CT) -0.62 18 >420 240 BCLL 0.0 Rep Stress Incr YES WB 0.77 Horz(CT) 0.09 12 n/a n/a BCDL 5.0 Code FBC20171TPI2014 Matrix-S LUMBER- BRACING - TOP CHORD 2x4 SP No. 1 D(flat) *Except* TOPCHORD 8-11: 2x4 SP No.2(flat) BOTCHORD 2x4 SP No. 1 (flat) *Except* BOTCHORD 12-21: 2x4 SP DSS(flat) WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 25=1 186/0-8-0, 12=1 186/0-3-8 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-25=-1180/0,11-12=-1179/0,1-2=-1168/0,2-3=-3056/0,3-4=-4375/0,4-5=-5228/0, 5-6=-5228/0,6-7 5104/0,7-9=-4419/0,9-10 3092/0,10-11=-1221/0 BOTCHORD 23-24=0/2260, 22-23=0/3869, 20-22=0/3869, 19-20=0/4872, 18-19=0/5228, 17-18=0/5228, 16-17=0/4909,15-16=0/3891,14-15=013891,13-14=0/2310 WEBS 11-13=0/1626,1-24=0/1588, 10-13=-1514/0,2-24=-1519/0, 10-14=0/1087,2-23=0/1108, 9-14=-1086/0, 3-23=-1 104/0, 9-16=0/718, 3-20=0/688, 7-16=-681/0, 4-20=-691/0, 7-17=0/475, 4-19=-47/847, 6-17=-576/232, 5-19=-363/0 PLATES GRIP MT20 244/190 MT20HS 187/143 MT18HS 244/190 Weight: 114 lb FT = 20%F, 11 %E Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Ina. F L Cort 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of cl sign parameters and property incorporate this design into the overall Nil" building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 3660 Job Truss Truss Type t_ Park Sq/Barcelona-A or C—TRAYPly T13452417 P2392ACT F5 ROOFTRUSS 5 1 Job Reference (optional) Mia-1-10naa Lumber, Bartow, I-L. i 1-3-0 4x5 1x3 1 4 4x4 2 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:00 2018 Page I ID*ItiEj_2vqrkv4uEJUYC2jFzkFng-qhqSv2JzQBnJ?mJoruMCOf?surylFhaliYDnMmzcgbD Scale = 1:35.6 3x3 = 3x5 1x3 11 3x3 3x4 = 1 X3 11 1x3 11 3x3 3x6 MT20HS FP = 45 = 1x3 3 4 5 6 7 8 9 10 11 12 3X3 11 4x6 3x8 MT1 8HS FP = 3x4 3x3 3x3 3x5 4x5 3x6 4X4 = 3x3 = 25 9 12-4-0 1 21 LQ---' 41 1 I-C) 2 -0 21-1 5-10-0 1 J6 -_0 Plate Offsets (X,Y)— [1:Edge,0-1-81, 08:0-11-8,Edgel LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Lid PLATES- GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.89 Vert(LL) -0.42 16-17 >599 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.72 Vert(CT) -0.58 16-17 >435 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.73 Horz(CT) 0.09 13 n/a n/a MT18HS 244/190 BCDL 5.0 Code FBC2017ITP12014 Matrix-S Weight: 109 lb FT = 20%F, I 1%E LUMBER- BRACING- TOPCHORD 2x4 SP No.11(flat) *Except* TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, 9-12: 2x4 SP No.2(flat) except end verticals. BOTCHORD 2x4 SP No.1(flat) *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 13-20: 2x4 SP DSS(flat) WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 23=1 15310-3-8, 13=1 153/0-4-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-23=-1 148/0, 1-2=-1 191/0, 2-3=-3015/0, 34=4220/0, 4-5=-4999/0, 5-6=-4999/0, 6-7=-4999/0, 7-8=-4640/0, 8-1 0=-3690/0, 10-11 =-2177/0 BOTCHORD 21-22=0/2249, 19-21 =013748, 18-19=0/4686, 17-1 8=0/4999, 16-17=0/4938, 15-16=0/4296, 14-15=0/3066, 13-14=0/1257 WEBS 11-13=-1671/0, 1-22=0/1538, 11-14=0/1279, 2-22=-1472/0, 10-14=-123710, 2-21=0/1064, 10-1 5=0/868, 3-21 =-I 020/0, 8-15=-843/0, 3-19=0/656, 8-16=0/479, 4-19=-647/0, 7-16=-455/0, 4-18=-66/766, 7-17=-295/536, 5-18=-351/0, 6-17=-256/75 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTtilk USA, Inc. FL Cort 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(E) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall saw building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing i s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fa to rication, storage, d el ive ry, erect !on and b racing of t russes and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/13arcelona-A or C—TRAY T13452418 P2392ACT F5A GABLE 1 Mid -Florida Lumber, Barlow, FL. 3x3 1 2 r 3 4 5 6 7 8 9 8.130 s Sep 15 2017 MiTelk Indu s, Inc. Fri Mar 9 10,52,01 2018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-ltOq6OKbBVvAdwu?PctRZtYDIFSf—JnuxCzKuCzcgbC Scale = 1:35.6 3x6 MT20HS FP 3X3 10 11 12 13 14 15 16 17 18 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 3x3 11 3x6 MT20HS FP = 3x3 lo-M 10-11-8 4-0 1 6 8:0 1 8-0- 2-8- 4-0-Q 0Q 0 11;0i 12F -0 1 101 1 1 1 lo' i 11t4;1 i 1 IFI-60 i 2 i 214;1 1-4-0 14-2. 14-11 1 TI: 1_ 711 1 0-8-8 0-3-8 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/def! L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.08 Vert(LL) n/a n/a 999 MT20 — 244/190 TCDL 10.0 Lumber DOL ' 1.00 BC 0.01 Vert(CT) n/a n/a 999 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 19 n/a n/a BCDL 5.0 Code FBC2017frPI2014 Matrix-R Weight: 94 lb FT = 20%F, 11 %E LIJII BRACING- TOPCHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3(flat) REACTIONS. All bearings 21-4-0. lb) - Max Grav All reactions 250 lb or less at joint(s) 36, 19, 27, 20, 21, 22, 23, 24, 25, 26, 35, 34, 33, 32, 30, 29,28 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) All plates are MT20 plates unless otherwise indicated. 2) All plates are 1x3 MT20 unless otherwise indicated. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131"X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. This item has been electronically signed and sealed by DRegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(g) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPIl Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq/Barcelona-A or C—TRAY T13452419 P2392ACT F6G ROOFTRUSS 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 0-1-8 H 1 1-3-0 2x6 1x3 1 2 6x6 2 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:02 2018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-m3yDJkKDyo1 1 E4TBzJOg644GPeaSjYFlAsitQezcgbB i 1-11-12 Scale = 1:32.6 4x6 11 5X6 11 4X6 11 2X6 11 3X6 11 3x6 11 4X6 11 7X6 11 3x6 11 3 4 5 6 7 23 8 9 10 11 9 4X6 11 6x6 3X6 11 5x6 11 2x6 11 3x6 11 3X6 11 3x6 11 6x7 6x6 1x3 = X LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d TCLL 40.0 Plate Grip DOL 1.00 TC 0.63 Verl(LL) 0.31 15-16 745 360 TCDL 10.0 Lumber DOL 1.00 BC 0.93 Vert(CT) 0.42 15-16 541 240 BCLL 0.0 Rep Stress Incr NO VVB 0.91 Horz(CT) 0.06 12 n/a n/a BCDL 5.0 Code FBC2017ITP12014 Matrix-S LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD BOTCHORD 2x4 SP-No.1 (flat) WEBS 2x4 SP No.3(flat) BOTCHORD REACTIONS. (lb/size) 12=1908/0-3-8,21=1244/0-8-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2620/0, 34 3761/0, 4-5=-5278/0, 5-6=-6147/0, 6-7=-6147/0, 7-8=-6398/0, 8-9=-5251/0, 9-1 0=-3782/0 BOTCHORD 20-21=0/1520,19-20=0/3761, 18-19=0/4588,17-18=0/6147,16-17=016147,15-16=0/6521, 14-15=0/6150,13-14=0/5251, 12-13=0/2334 WEBS 10-12=-2972/0,2-21=-1918/0,10-13=0/1915,2-20=0/1456,9-13=-190610,9-14=0/71 1, 3-20=-14B0/0,3-19=01706,8-14=-1 165/D, 4-19=-1072/0, 8-15=0/396, 4-18=0/993, 7-15=-382/77, 5-18=-1 344/0, 7-16=-8371363, 5-17=-62/432 PLATES GRIP MT20 244/190 Weight: 152 lb FT = 20%F, I 1%E Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Bearing at Joint(s) 21 considers parallel to grain value using ANSI[TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 3) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 357 111 down at 13-5-8, and 357 lb down at 15-5-8, and 357 lb down at 17-5-8 on top chord. The design/selection of such connection device(s) is the responsibility of others. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (pl Vert: 12-21=-10, 1-11=-100 Concentrated Loads (lb) Vert: 10 357(1`) 9=-357(F) 23 357(1`) This item has been electronically signed and sealed by CiRegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc, Fl. Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 re, 101031205 BEFORE USE. Design valid for use only with MiTek(l) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C TRAY T13452420 P2392ACT F7G ROOFTRUSS 1 1 Job Reference (ootional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:03 2018 Page 1 ID:ItjEj_2vqrkv4uEJUYC2jFzkFng-EGVbX4Ld69usElNWlvveldSk2wWSO?BOVSRy5zcgbA 0-1-8 H 1 1-3-0 1-11-12 Scale = 1:32.6 2x6 1x3 I 2 7x6 11 4X6 11 3X8 11 3x6 11 2x6 11 5X6 11 4x6 11 4X6 11 6x6 3x6 11 2 3 4 23 5 6 7 8 9 10 11 9 5X6 11 6x7 3X8 11 3x6 11 2x6 11 4X6 11 4x6 11 3X6 11 6x6 6X6 1X3 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) - I/defl L/d TCILL 40.0 Plate Grip DOL 1.00 TC 0.53 Vert(LL) 0.30 17 769 360 TCDL 10.0 Lumber DOL 1.00 BC 0.95 Vert(CT) 0.41 17 559 240 BCLL 0.0 Rep Stress Incr NO WEI 0.88 Horz(CT) 0.06 12 n/a n/a BCDL 5.0 Code FBC2017fTP12014 Matrix-S LUMBER- BRACING - TOP CHORD 2x4 SP NO.2(flat) TOPCHORD BOTCHORD 2x4SPNo.l(flat) WEBS 2x4 SP No.3(flat) BOTCHORD REACTIONS. (lb/size) 12=1281/0-3-8,21=1758/0-8-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (ib) or less except when shown. TOPCHORD 2-3=-3572/0, 3-4=-5014/0, 4-5=-6426/0, 5-6=-6667/0, 6-7=-6667/0, 7-8=-5422/0, 8-9=-3866/0, 9-1 0=-2693/0 BOTCHORD 20-21 =0/2174, 19-20=0/5014, 18-1 9=0/6029, 17-18=0/6667, 16-17=0/6667, 15-16=0/6103, 14-15=0/4775, 13-14=0/3866, 12-13=0/1 549 WEBS 10-1 2 1 971/0, 2-21 =-2744/0, 10-13=0/1 514, 2-20=0/1 850, 9-13=-1 520/0, 9-14=0/773, 3-20=-1 870/0, 3-19=0/820, 8-14=-1 179/0, 4-19=-1 316/0, B-15=01856, 4-1 8=0/618, 7-15=-901/0, 5-18=-712/162, 7-16=-80/1157, 5-17=-385/145, 6-16=-430/0 PLATES GRIP MT20 244/190 Weight: 152 lb FT = 20%F, 11 %E Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1 ) Unbalanced floor live loads have been considered for this design. 2) Bearing at joint(s) 21 considers parallel to grain value using ANSIrTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 239 lb down at 1-9-8, 239 lb down at 3-9-8, and 239 111 down at 5-9-8, and 239 lb down at 7-9-8 on top chord. The design/selection of such connection device(s) is the responsibility of others. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 12-21 =-1 0, 1 -11 =-1 00 Concentrated Loads (lb) Vert: 2=-239(B) 3=-239(B) 5=-239(B) 23=-239(B) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Ragan PE No.58126 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev, 1010312015 BEFORE USE. Design valid for use only with MiTek(ID connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must venfy the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Park SqtBarcelona-A or CjRAY T13452421 P2392ACT F8 ROOFTRUSS 4 Job Reference (optional) Mid-i-loncla Lumber, Barlow, FL. 13 cii 0-1-8 H i 1-3-0 8' 130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:04 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-iS3zkPMTUQHIUNca4kQ8BVAfYSOJBcJKd9B—VXzcgb9 071:P ScAFe'= 1:16.8 1x3 3x3 1 X3 11 1 X3 11 3x3 3x3 = 1 3x3 2 3 4 5 6 lx3 3x3 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 :Plate Grip DOL 1.00 TC 0.39 - Vert(LL) -0.05 10-11 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.40 Vert(CT) -0.06 10-11 >999 240 BCLL 0.0 Rep Stress Incir YES WB 0.30 Horz(CT) 0.01 7 n/a n1a BCDL 5.0 Code FBC2017fTP12014 Matrix-S LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORC BOT CHORD 2x4 SP NO.2(flat) WEBS 2x4 SP No.3(flat) BOTCHORC REACTIONS. (lb/size) 12=539/0-3-8,7=539/0-3-8 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-1 2=-53510, 6-7=-535/0, 1-2 492/0, 2-3=-1 089/0, 3-4=-1 089/0, 4-5=-1 089/0, 5-6=-492/0 BOTCHORD 10-11 =0/912, 9-1 0=0/1 089, 8-9=0/912 WEBS 6-8=0/632, 1 -11 =0/632, 5-8=-583/0, 2-11 =-583/0, 5-9=0/380, 2-1 0=0/380 3x3 = Weight: 54 lb FT = 20%F, 11 %E Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131"X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. Fl. Cerl:6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 AWARNING. ftify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Welke connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication. storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPl1 Quality Criteria, DSB-89 and ECS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sq/Barcelona-A or C—TRAY T13452422 P2392ACT F8A ROOFTRUSS 1 Job Reference (ootionah Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:05 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2iFzkFng-BedLyIN5FjPc5XBmeRxNjjioFsjww4JUspxYlzzcgb8 0-1-8 1-3-0 1-11-0 014H11i Scale = 1:16.8 13 1x3 = 3x3 1 x3 11 1 x3 11 3x3 3x3 = 1 3x3 2 3 4 5 15 6 1x3 3x3 = 14 11 10 9 3X3 7 TRUSS IS NOT DESIGNED TO SUPPORT CONCENTRATED LOADS AT ITS CANTILEVERED END(S). LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/clefl Ud TCLL 40.0 Plate Grip DOL Do TC 0.53 Vert(LL) 0.07 10-11 999 360 TCDL 10.0 Lumber DOL 1.00 BC 0.50 Vert(CT) 0.09 10-11 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.25 Horz(CT) 0.01 8 n/a n/a BCDL 5.0 Code FBC2017f-rPI2014 Matrix-S LUMBER- BRACING- PLATES GRIP MT20 244/190 Weight: 54 Ito FT = 20%F, 11 %E TOPCHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 7-8. REACTIONS. (lb/size) 12=452/0-3-8, 8=626/0-3-8 Max Grav 12=460(LC 3), 8=626(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (b) or less except when shown. TOPCHORD 1-12=-464/0,1-2=-415/0,2-3=-76810,3-4=-768/0,4-5 76810 BOTCHORD 10-11=0/739,9-10=0/768,8-9=0/423 WEBS 1-11=01531,5-8=-730/0,2-11=-451/0,5-9=0/49D NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 3361D Date: March 9,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473 rev, 1010312015 BEFORE USE. ELMER* Design valid for use only with MiTeUD connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Instilute, 218 N. Lee Street, Suite 312, Aexandria, VA 22314. Tampa, FIL 36610 Job Truss Truss Type oty Ply Park Sq/Barcelona-A or C-TRAY T13452423 P2392ACT F9 ROOFTR USS 4 Job Reference (optional) mia-t-ionaa Lumber, Bartow, F-L. i 1-3-0 -1 i 1-4-8 i 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:06 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-frBj95OjOlXTjhmyC9TcGwFv-GyJfV?d5Tg5ZQzcgb7 i 1-5-8 Scale= 1: 16.7 1 X3 11 1x3 11 3X6 MT20HS 1 x3 11 1 x3 11 3x6 I 3x6 2 3 4 5 6 7 1 3.3 11 9 3x3 = 3.3 11 4-4-8 1 7:6-0 i 1 14-4-8 011 3-0-0 N'210 LOADING (ps SPACING- 2-0-0 CS1. TCLL 40.0 Plate Grip DOL 1.00 TC 0.78 TCDL 10.0 Lumber DOL 1.00 BC 0.94 BCLL 0.0 Rep Stress Incr YES WB 0.35 BCDL 5.0 Code FBC2017/TP12014 Matrix-S LUMBER- TOPCHORD 2x4 SP No.2(flat) BOTCHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 14=440/Mechanical, 8=251 /Mechanical, 9=280/0-8-0 Max Grav 14=443(LC 3), 8=251 (LC 1), 9=321 (LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (1b) or less except when shown. TOPCHORD 1-14=-485/0,7-8=-320/0,1-2=-567/0,2-3=-567/0,3-4=-567/0, 4-5=-417/0, 5-6=-417/0, 6-7=-417/0 BOTCHORD 12-13=D/567, 11-12=01823, 10-11 =0/823, 9-1 0=0/417 WEBS 1-1 3=0/740, 4-12=-337/0, 2-13=-312/0, 7-9=0/544, 4-1 0=-532/0, 6-9=-385/0 DEFL. in (loc) I/defl .- Ud PLATES- GRIP Vert(LL) -0.12 10-11 >726 360 MT20 244/190 Vert(CT) -0.17 10-11 >531 240 MT20HS 187/143 Horz(CT) 0.01 8 n/a n/a Weight: 53 lb FT = 20%F, 11 %E BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 10-11. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Refer to girder(s) for truss to truss connections. 4) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J, gRegan PE No.58126 MiTak USA, Inc. F L Cart 6634 6904 Parke East Blvd. Tampa FL 33,610 Date: March 9,2018 AWARNING. Verify design parameters and READ NOrES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(E) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall HER building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Type Park Sq/Barrelona-A or C—TRAYTtyPly T`13452 4 P2392ACT GABLE 1 1 Job Reference (ootionah 2 1x3 11 3 1x3 11 ts.i6u s bep It, ZU11 Mllelk inaustries, Inc. --n mar 9 iu:bz:ufj zulu Flage 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-frBj95OjOlXTjhmyC9TcGwF4qGApfa_d5Tg5ZQzcgb7 Scale= 1:12.7 4 1x3 11 5 1X3 11 6 3X3 11 9 12 11 10 9 8 7 3x3 11 1x3 11 1x3 h 1x3 11 1 X3 11 3X3 11 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/def] L/d PLATES GRIP JCLL 40.0 Plate Grip DOL 1.00 TC 0.09 Vert(LL) n/a nia 999 MT20 - 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress lncr YES WB 0.03 Horz(CT) 0.00 7 n/a n/a BCDL 5.0 Code FBC2017/TP12014 Matrix-R Weight: 33 lb FT = 20%F, 11 %E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3(flat) REACTIONS. All bearings 6-10-0. lb) - Max Grav All reactions 250 Ito or less at joint(s) 12, 7, 8, 9, 11, 10 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Gable requires continuous bottom chord bearing. 2) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 3) Gable studs spaced at 1-4-0 oc. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. This item has been electronically signed and sealed by QRegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 M!Tok USA, Ina. FL Con 6634 69D4 Parke East Blvd. Tampa FL 33,61 D Date: March 9,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(S) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss uss Type Qty Ply Park Sq/Barcelona-A or C—TRAY I GA 52425 P2392ACT F10 B L E 1 1 Job Reference (opt ona ivua-riorma LUmDer, banow, t-L. 004 1 1x3 2 1x3 16 1x3 = 1x3 = 15 5.113t)sbep 1b2017 MiIeK Industries, Inc. Fn Mar 9 10:51:522018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-38LRDJDxJkmSlXiGNDCKizghJcOaNFYZtIHM4EzcgbL 3 1x3 11 4 1x3 11 5 IX3 11 6 1x3 11 7 3X3 11 Scale = 1: 13.4 14 13 12 11 10 9 8 1x3 11 1 X3 11 1 x3 11 1 X3 11 1x3 11 1X3 11 3X3 11 37 4 -41_hl 1 _ 112 14 02 1' LOADING (psf) SPACING- 2-0-0 CsI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.09 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr NO WB 0.03 Horz(CT) -0.00 8 n/a n/a BCDL 5.0 Code FBC2017rTP12014 Matrix-R Weight: 35 lb FT = 20%F, 11 %E LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 7-2-8 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verlicals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. OTHERS 2x4 SP No.3(flat) REACTIONS. All bearings 7-2-8. lb) - Max Grav All reactions 250 lb or less at joint(s) 14, 11, 12, 13, 10, 9 except 8=1 291 (LC 1) FORCES. (b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 7-8=-1287/0 NOTES- 1) Gable requires continuous bottom chord bearing. 2) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 3) Gable studs spaced at 1-4-0 oc. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Dd (0.131 X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate lncrease=1.00 Uniform Loads (plf) Vert: 8-14=-10, 1-7=-100 Concentrated Loads (lb) This item has been Vert: 7=-1265 electronically signed and sealed by CiRegan, Philip, PE using a Digital Signature. Printed copies of this - document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Inc. Fl. Cort 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 WARNING Verify d..ig. parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(b connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSl/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452426 P2392ACT F11 ROOFTRUSS 6 Job Reference (optional) rvuu-rivilU LUFTIVel, uaRow,rL. 0-1-8 i 1-3-0 3x3 12 it 6'1 3U s z5ep I b 2ul t MI I eK Inaustnes, Inc. F- ri Mar 9 10:51:54 2018 Page 1 1 D:ItiEj_2vqrkv4uEJUYC2jFzkFng-?XTBe?ECrLOAHrrfVeFonOlxvQ—?r6msKcmS86zcg bJ 3x3 2 3 3x3 3x6 4 1x_ 1X3 1 x3%/ 3X3 IX3 11 1X3 11 3x3 8 7 6 5 3x3 11 Scale = 1: 12.9 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate. Grip DOL 1.00 TC 0.47 Vert(LL) -0.02 6-7 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.33 Vert(CT) -0.02 6-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.18 Horz(CT) 0.00 5 n/a n/a BCDL 5.0 Code FBC2017[TP12014 Matrix-S Weight: 39 lb FT = 20%F, I 1%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=364/0-8-0, 5=364/Mechanical FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (D) or less except when shown. TOPCHORD 1-10=-358/0, 4-5=-359/0,1-2=-269/0,2-3=-525/0,3-4=-279/0 BOTCHORD 8-9=0/525, 7-8=0/525, 6-7=0/525 WEBS 4-6=0/371, 1-9=0/366, 3-6=-334/0, 2-9=-348/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. VRegan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 3361D Date: March 9,2018 AWARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 re, 1010312015 BEFORE USE. Design valid for use only with MiTek(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCS] Building Component 6904 Parke East Blvd. Safety Infortration available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FIL 36610 Job Truss Truss Type Qty Ply Park Sq[Barcelona-A or C—TRAY T13452427 P2392ACT F11G ROOFTRUSS 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 12 0-1-8 k_ 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:51:54 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-?XTBe?ECrLOAHrrfVeFonOlqtQuGr3ksKcmS86zcgbJ 3x3 3x6 1 3x4 2 3 3x3 4 1X3 x3 3X4 IX3 1x3 3x4 8 7 6 3x3 11 Scale = 1:12.9 LOADING (pso TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 5.0 SPACING- 2-0-0 Plate Grip DOL 1.00 Lumber DOL 1.00 Rep Stress Incr NO Code FBC2017rTP12014 CS1. TC 0.92 BC 0.76 WEI 0.37 Matrix-S DEFL. in Vert(LL) -0.04 Vert(CT) -0.05 Horz(CT) 0.01 loc) I/defl Ud 6-7 >999 , 360 6-7 >999 240 5 n/a n/a PLATES GRIP MT20 244/190 Weight: 39 lb FT = 20%F, 1 1%E LUMBER- BRACING- TOPCHORD 2x4SPNo.l(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 0=774/0-8-0, 5=774/0-3-8 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-10=-767/0,4-5=-769/0,1-2=-565/0,2-3=-1119/0,3-4=-585/0 BOTCHORD 8-9=0/1 119, 7-8=0/1 119, 6-7=0/1 119 WEBS 4-6=0/779.1-9=0/767, 3-6=-725/0, 2-9=-75310 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Girder carries tie-in span(s): 7-0-0 from 0-0-0 to 6-11-4 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (pl Vert: 5-10=10, 1-4=-224 This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed,copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Ind. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the o era[l Nit building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is atays required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, OSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Infonnation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply Park Sq[Barcelona-A or C—TRAY T13452428 P2392ACT F12 ROOFTRUSS 3 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. i 1-3-0 3x3 I 3x6 2 10 3x3 11 8.13U s 6ep 15 ZU1 I Mi I elk I nclustnes, Inc. f-n mar 9 wbi:bb zuid vage i ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-xwax3gGSMyHtW9?lc2HGsprHREgXJOE9nwFZD?zcgbH 3 3x3 = 3x3 1 X3 11 1 x3 11 3x3 9 7 6 3x6 4 5 3X3 11 Scale = 1: 12.9 9 LOADING (psf) SPACING- 2-0-0 cSI. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.47 Vert(LL) 0.02 8-9 999 - 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.33 Vert(CT) 0 02 8-9 999 240 BCLL 0.0 Rep Stress Incr YES WEI 0.18 Horz(CT) 0.00 5 n/a n/a BCDL 5.0 Code FBC2017TTP12014 Matrix-S Weight: 40 lb FT = 20%F, 1 1%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=367/Mechanical, 5=367/Mechanical FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 11-10 361/0, 4-5=-361/0,1-2=-281/0,2-3=-533/0,3-4=-281/0 BOTCHORD 8-9=0/533, 7-8=0/533, 6-7=0/533 WEBS 4-6=0/375, 1-9=0/375, 3-6=-34210, 2-9=-342/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. 0'Ragan PE No.58126 MiTek USA, Inc, FIL Cert 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(ID conneclors. This design is based only upon parameters shown, and is for an individual building component, not truss system, Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall ibuilding design, Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" s always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSItTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Truss Truss Type Qty Ply Park Sq/Barcelona-A or C — TRAY T1345242 FT1 SPECIAL 1 2 all Mid -Florida Lumber, Barlow, FL. 8,130 s 6ep 1b 2011 Mi I eK Industries, Inc. t-n Mar V 1u:!)Z:Ut$ Zulb Flage I ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-bDJUanP_XenAy?wLJaV4LLKCS3cl7FnwYn9Celzcgb5 1 4-5- 1 6-1: -2 131 1 !1-,2 12 _'0 1 1 -80-1 _ '_0 1 2--3-014i_ 1- 114 2 _ -14 _1'4 2'1-U 2-:1 142-i-11 20 .1_14 1 _ 1 4 2-1':144 2- - 1 Scale = 1:37.1 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 7x6 1.5x4 5x8 1.5X4 48 1,5x4 4x8 1 2 3 4 23 5 6 7 24 5x5 4x10 1.5X4 6x6 8 25 9 10 2611 22 12 4x4 11 8xl2 2X4 8x12 MT20HS 2X4 4X8 2x4 410 2X4 6x10 3X4 11 1 1 1 =4 2 1 '1_10-821:1 V1 -_1 4 2 1Z 14 2U1 - 141 2;1' 2 2;;4 V14 271 -;14 114 2-3-14 Plate Offsets (X,Y)— [8:0-2-8.0-3-41, [19 0-6-0,0-5-41 LOADING (psf]i SPACING- 2-0-0 CS1. DEFL. in loc). . I/defl.. L/d PLATES. GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.98 Vert(LL) -0.71 17 >366 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.99 Vert(CT) -0.97 17 >266 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr NO W3 0.97 Horz(CT) 0.09 12 n/a n/a BCDL 5.0 Code FBC2017ITP12014 Matrix-S Weight: 244 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP DSS *Except* TOP CHORD Structural wood sheathing directly applied or 1-5-14 oc purlins, 8-11: 2x4 SP No.2 except end verticals. BOTCHORD 2x6 SP DSS BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 *Except* 1-21,3-21,3-19,5-19,5-17,11-13,9-13,9-15,7-15,7-17: 2x4 SP No.2 REACTIONS. (lb/size) 22=3703/0-7-4, 12=275810-3-8 Max Uplift 22=-530(LC 4), 12=-382(LC 5) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-22=-3295/478,1-2=-6770/963,2-3=-6770/963,3-4=-15381/2144,4-5=-15381/2144, 5-6=-16966/2286, 6-7=-16966/2286, 7-8=-12361/1677, 8-9 12361/1677' 9-10=-5108/703, 10-11=-5108/703, 11-12=-2388/337 BOTCHORD 21-22=-67/464,20-21=-1760/12473, 19-20=-1760/12473, 18-19=-2442/17783, 17-18=-2442/17783, 16-17=-2113/15662, 15-16=-2113/15662, 14-15=-1 354/9890, 13-14=-1354/9890, 12-13=-48/341 WEBS 2-21=-699/124, 3-20=-33/344, 4-19=-656/116, 5-18=-47/453, 6-17=-7731123, 7-16=-65/580, 9-14=-44/429, 10-13=-424/80, 1-21 =-980/6901, 3-21 =-6241/872, 3-19=-44513182, 5-19=-2628/377, 5-17=-894/171, 11-13=-716/5208, 9-13=-5233f712, 9-15=-381/2703, 7-15=-3613/526, 7-17=-247/1427 NOTIES- 1) 2-plytrussto be connected togetherwith 10d (0.131"x3") nails asfollows: This item has been Top chords connected as follows: 2x4 - 1 row at 0-4-0 oc. electronically signed andBottomchordsconnectedasfollows: 2x6 - 2 rows staggered at 0-9-0 oc. sealed by ORegan, Philip, PEWebsconnectedasfollows: 2x4 - I row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (8) face in the LOAD CASE(S) section. Ply to using a Digital Signature. ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. Printed copies of this 3) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat. document are not considered 11; Exp B; Encl., GCpi=O.l 8; IVIWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 signed and sealed and the 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. signature must be verified 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. oin any electronic copies. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Philip J. O'Regan PE No.58126 will fit between the bottom chord and any other members. MiTok USA, Inc. FL Cart 6634 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 530 lb uplift at joint 22 and 382 lb uplift 6904 Parke East Blvd. Tampa FIL 33610 at joint 12. Date: 9) Girder carries tie-in span(s): 5-0-0 from 0-0-0 to 10-11-4; 2-10-0 from 16-3-4 to 21-6-12; 5-0-0 from 0-0-0 to 10-11-4 March 9,2018 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 429 lb down and 62 lb up at 17"'flanomeIMMIM Sm" c flAR(9_P'P.R&3esigo parameters andREAD NOTES ON THIS AND INCLUDEDMITEK REFERENCE PAGE 11,111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTelkV connectors. This design is based only upon parameters shown, and is for an individual building component, not F=R EH truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall AWN building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' s always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSITTPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Type Qty Ply Park SqlBarcelona-A or C—TRAYTruss T1345242 P2392ACT FT11 SPECIAL 1 2 all Mid -Florida Lumber, Bartow, FL. 8,130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:08 2018 Page 2 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-bDJUanP—XenAy''wLJaV4LLKCS3cl7FnwYn9Celzcgb5 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-6=-373, 6-25=-100, 25-26=-239, 11-26=-1 15, 12-22=-10 Concentrated Loads (11b) Vert: 6=-429 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mli-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTektp connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek' fa brication, storage, delivery, a rection a nd braci n g of truss as and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Truss Truss Type Qty Ply Park Sq[Barcelona-A or C—TRAY T13452430 FT2 SPECIAL 1 2 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10-52:10 2018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-XcQE?TRE3GluCl4jR?XYQmoZjtL2bE6D?5eJiBzcgb3 1 4 6-7- 89-4 1 1,2 1512 4 7 12 1 - 0 2 1 -80109 2'--I-ol 42.3- 112. . 151'4 _1 _164 14 2 11 11 4 2 114 2_1114 2--16114 Scale = 1:37.1 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 5X5 1.5X4 4x10 1.5X4 48 1.5x4 4x8 5x5 410 1.5x4 5X6 1 2 3 4 23 5 6 7 24 8 2526 9 10 11 22 12 3X4 6x8 2X4 8x8 MT20HS 2X4 48 2X4 4x10 2X4 7x8 3x4 2 2 1 '1 1114711'14 1 2 1 14 1--114 2':1'14 2-__IlIl'42.1-10 2-1!:1'4 2 IZ14 2' 1'1'4 Plate Offsets (X.Y)— [8:0-2-8.0-3-41, [19:0-3-12,0-5-41 LOADING (psf), SPACING- 2-0-0 cSI. DIEFL. in loc) I/defl Ud TCLL 40.0 Plate Grip DOL 1.00 TC 0.93 Vert(LL) 0.55 17 472 360 TCDL 10.0 Lumber DOL 1.00 BC 0.82 Vert(CT) 0.82 17 316 240 BCLI_ 0.0 Rep Stress Incr NO WB 0.66 Horz(CT) 0.07 12 n/a n/a BCDL 5.0 Code FBC2017ITP12014 Matrix-S LUMBER- BRACING- TOPCHORD 2x4 SP No.1 TOPCHORD BOTCHORD 2x6 SID No.1 *Except* 12-19: 2x6 SP DSS BOTCHORD WEBS 2x4 SP No.3 *Except* 1-21,3-21,3-19,5-19,5-17,11-13,9-13,9-15,7-15,7-17: 2x4 SP No.2 REACTIONS. (lb/size) 22=1900/0-7-4, 12=2367/0-3-8 Max Uplift 22=-283(LC 4), 12=-372(LC 5) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-22=-1 693/259, 1-2=-3663/547, 2-3=-3663/547, 3-4=-9559/1435, 4-5=-9559/1435, 5-6=-13326/2034,6-7=-13326/2034,7-8=-11929/1870,8-9=-11929/1870,9-10=-4594/725, 10-11=-4594/725, 11-12=-20881336 BOTCHORD 20-21=-1082/7222, 19-20=-1082/7222, 18-19=-1871/12396, 17-18=-1871/12396, 16-17 2163/14153, 15-16=-2163/14153, 14-15=-1487/9346, 13-14=-1487/9346, 12-13=-46/286 WEBS 3-20=-25/270, 5-18=-68/526, 6-17=-686/139, 7-16=-81/586, 8-1 5=-723/150, 9-14=-44/394, 1-21 =-562/3766, 3-21 =-3895/586, 3-19=-406/2557, 5-19=-3105/520, 5-17=-225/1018, 11-13=-742/4706, 9-13=-5201/834, 9-15=-451/2826, 7-15=-2435/363, 7-17=-905/176 PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 244 lb FT = 20% Structural wood sheathing directly applied or 1-11-14 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18, MWFRS (directional); Lumber DOL=11.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in ail areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 283 lb uplift at joint 22 and 372 lb uplift at joint 12. 9) Girder carries tie-in span(s): 5-0-0 from 10-7-12 to 21100816-6-12; 5-0-0 from 10-7-12 to 16-6-12 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 413 lb down and 131 lb up at This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 paip f th.erspdrameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 r— 1010312015 BEFORE USE. Ardiffln PAy'uAitKzTo:`i'th MiTeWD connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabdcation, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452430 P2392ACT FT2 SPECIAL 1 2 Job Reference (ootional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:10 2018 Page 2 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-XcQE?TRE3GluCl4jR?XYQmQZjtL2bE6D?5eJ!Bzcgb3 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate lncrease=1.00 Uniform Loads (plf) Vert: 1-6=-100, 6-26=-298, 11-26=-100, 12-22=-10 Concentrated Loads (lb) Vert: 6=413 25=-363 WARNING - Verify design paramet and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mit-7473 rev, 1010312015 BEFORE USE. De sign valid for use only with MiTek& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' s always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Type Qty Ply Park Sq[Barcelona-A or C_TRAY JTrussP2392ACTFT3SPECIAL 1 3 all Mid-Fioricla Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:11 2018 Page 1 ID:ItjEL2vqrkv4uEJUYC2jFzkFng-?o — cCpRsqZ9lpSfw—i2nz_yjwHewKbBMEIOsFdzcgb2 1-11:8 3-9-4 1-7 1 9-,2 12-,l IT4-7_' 2 1 J 0 Tg 1 112 -8 1 1 _2- 0:22 .12 11 1-12 _12 -1-12 12 Scale = 1:28.8 3x4 6xl 2 MT20HS 11.5X4 5xB 1.5X4 4x6 6X8 1.5x4 6x8 = 1 21 2 3 4 5 6 7 8 9 22 5x8 MT20HS THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 1:112 11 2 1 11 -4112 1 1 M2 I-W11 '1 1 llzll 1%'12 2 Plate Offsets (X,Y)— [2:0-3-12.0-2-41 LOADING (pso SPACING- 1-4-0 CS1. TCLL 40.0 Plate Grip DOL 1.00 TC 0.96 TCDL 10.0 Lumber DOL 1.00 BC 0.98 BCLL 0.0 Rep Stress Incr NO WB 1.00 BCDL 5.0 Code FBC2017rTPI2014 Matrix-S LUMBER- TOPCHORD 2x4SPNo.1D BOTCHORD 2x6 SP DSS WEBS 2x4 SP No.3 *Except* 2-20,2-18,4-18,4-16,6-16,7-15,7-13,9-13,9-11: 2x4 SP No.2 DEFL. in (loc) I/def! Ud Vert(LL) -0.40 16 >490 360 Vert(CT) -0.55 16 >356 240 Horz(CT) 0.07 11 n/a n/a 1.5x4 10 20 2x4 11 10x12 2x4 11 5x8 4x6 2X4 11 6X8 2X4 11 11 4x4 — — PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 280 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 2-1-8 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 17-18,16-17. REACTIONS. (lb/size) 20=7232/0-8-0, 11 =3189/Mechanical MaxUplift 20=-1069(LC4), ll=-460(LC5) FORCES. (b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-20=-680/108, 1-2=-663/98, 2-3=-21440/3139, 3-4=-21440/3139, 4-5=-24927/3610, 5-6=-24927/3610, 6-7=-20795/3002, 7-8=-1 0590/1529, 8-9=-1 0590/1529, 9-1 0=-279/40 BOTCHORD 19-20=-1779/12083, 18-19=-1779/12083, 17-18=-4265/29296, 16-17=-4265129296, 15-16=-3002/20795, 14-15=-2341/16211, 13-14=-2341/16211, 12-13=-808/5596, 11-12=-808/5596 WEBS 3-18=-1075/176, 4-17=-353/59, 6-15=-2295/346, 7-14=-37/314, 2-20 112918/11901, 2-18=-1539/10584, 4-18=-8887/1276, 4-16=-4943/742, 6-16=-695/4673, 7-15=-761/5186, 7-13=-6358/921. 9-13=-815/5650. 9-11 =-6030/871 NOTES- 1) 3-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-4-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - I row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft, L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpj=0.18; MWFRS (directional); Lumber DOL=11.60 plate grip DOL=11.60 4) Provide adequate drainage to prevent water poncling. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1069 lb uplift at joint 20 and 460 lb uplift at joint 11. 10) Girder carries tie-in span(s): 16-8-0 from 0-0-0 to 5-8-0 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 6305 lb down and 911 lb up at 5-3-8 on top chord. The design/selection of such connection device(s) is the responsibility of others. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified On any electronic copies. Philip J. O'Regan PE No.58126 MiTok USA, Inc. Fl. Cod 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9.2018 7CWWAIRP-RAPPy 3-ign parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekV connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Nil' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storag a, delive ry, erect ion and bracing of trusses and tru ss system s, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type QtY Ply Park Sq/Barcelona-A or C—TRAY T13452431 P2392ACT FT3 SPECIAL 1 3 Job Reference ODtionah Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:11 2018 Page 2 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-?o—cCpRsqZglpSfw—i2nz_yjwHewKbBMEIOsFdzcgb2 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-4=-604, 4-10=-67, 11-20=-7 Concentrated Loads (11b) Vert: 4=-6305 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(ID connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrP11 Quality Criteria, DSB.89 and BCS] Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Instfute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 1 Tampa, FL 36610 Job Truss Truss Type Ply Park Sq/Barcelona-A or C_TRAYOty T13452432 P2392ACT FT4 SPECIAL 1 2 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Feb 12 2018 MiTek Industries, Inc. Fri Mar 9 14:46:15 2018 Page I ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-tmVmPdLOFhRbcBuDAm5?K9wbhJF?N7YdqdKVoHzcels 2-9-5 5-4-14 8-2-4 2-9-5 2-7-9 2-9-6 THIS TRUSS IS NOT SYMMETRIC. Scale = 1 15.7 PROPER ORIENTATION IS ESSENTIAL. 7x6 = 44 4x4 = 1.5X4 1 9 2 3 10 11 4 8 2.4 11 5x5 LOADING (psf) SPACING- 2-G-0 CS1. DEFL. in loc) Ildefl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.68 Vert(LL) -0.05 6-7 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.61 Vert(CT) -0.07 6-7 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.88 Horz(CT) 0.01 5 n/a n/a BCDL 5.0 Code FBC2017fTP]2014 Matrix-P Weight: 91 lb FT = 20% ILLI BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x6 SP No.2 except end verlicals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (ib/size) 8=1892/Mechanical, 5=2261/0-8-0 Max Uplift 8=-468(LC 4), 5=-558(LC 5) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-8=-1657/419,1-9=-3464/856,2-9=3464/856,2-3=-3658/903,4-5=-597/156 BOTCHORD 7-13=-856/3464, 6-13 856/3464, 6-14=-903/3658, 5-14=-903/3658 WEBS 2-7=-959/263, 1-7=-911/3686, 3-5=-3892/961 NOTES- 1) 2-ply truss to be connected together with 1 Od (0. 131 "x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Part. Encl., GCpi=0.55; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf boftorn chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 This item has beenwidewillfitbetweenthebottornchordandanyothermembers. 7) Refer to girder(s) for truss to truss connections. electronically signed and 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 468 to uplift at joint 8 and 558 lb uplift sealed by ORegan, Philip, PE at joint 5. using a Digital Signature. 9) Girder carries tie-in span(s): 6-8-0 from 0-0-0 to 8-7-4 Printed copies of this 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 398 lb down and 97 lb up at document7-0-0 on top chord, and 256 lb down and 62 lb up at 1-4-8, 256 lb down and 62 lb up at 3-4-8, and 256 lb down and 62 lb up at are not considered 5-4-8, and 258 lb down and 63 to up at 7-4-8 on bottom chord. The design/selection of such connection device(s) is the signed and sealed and the responsibility of others. signature must be verified LOAD CASE(S) Standard on any electronic copies. Philip J. O'Regan PE No.58126 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 MiTak USA, Inc. IFL Cart 6634 Uniform Loads (plf) 6904 Parke East Blvd. Tampa FL 33610 Vert: 1-4=-335, 5-8=-10 Date: Concentrated Loads (lb) Vert: 6 256fl 10=-398 12=-256(F) 13=-256(F) 14=-258(F) March 9,2018 WARNING - Verify design parameters andREAD NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEMII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekID connectors. This design is based only upon parameters shown, and is for an individual building component, not a t niss system. Before use, th a build Ing desig ner m u st verry th a a pplicability of de sign pa ra mete is and properly I ncorporate th i s design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is aKvays required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452433 P2392ACT FT5 ROOF TRUSS 2 Job Reference (optional) Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10 52 13 2018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-yB6NdUT6MBOT3mol675F2P2Ez4LIobhfi3tzJWzcgbO 2-4-9 4-7-7 7-0-0 2-4-9 2-2-13 24-9 THIS TRUSS IS NOT SYMMETRIC. Scale = 1: 13.2 PROPER ORIENTATION IS ESSENTIAL. 5X6 4x4 4x6 1.5x4 11 1 2 3 4 2x4 4x6 2-4-9 4-7-7 7-0-0 2-4-9 2-2-13 2-4-9 Plate Offsets (X,Y)— [6:0-3-0,0-4-41 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.29 Vert(LL) -0.04 6-7 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.95 Vert(CT) -0.06 6-7 >999 240 BCLL 0.0 Rep Stress Incr NO WEI 0.61 Horz(CT) 0.01 5 n/a n/a BCDL 5.0 Code FBC2017/TP12014 Matrix-P Weight: 78 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 5-6-6 oc purlins, BOTCHORD 2x6 SP No.1 except end verticals. WEBS 2x4 SP No.3 *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 1-7,2-6,3-5: 2x4 SP No.2 REACTIONS. (lb/size) 8=1290/0-3-8, 5=2968/0-4-8 Max Uplift 8=-165(LC 4), 5=-635(LC 4) Max Grav 8=2225(LC 2), 5=3412(LC 2) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (11b) or less except when shown. TOPCHORD 1-8=-1723/156,1-2=-3773/317, 2-3=-4684/631 BOTCHORD 6-7=-317/3773, 5-6=-631/4684 WEBS 1-7=-345/4104, 2-7=-7671199, 2-6=-344/1263, 3-6=-242/1899, 3-5=-5096/687 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-3-0 oc. Webs connected as follows: 2x4 - I row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water poncling. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 165 lb uplift at joint 8 and 635 lb uplift at joint 5. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 357 lb down at 1-9-4, 357 lb down at 3-9-4, and 357 lb down at 5-9-4, and 2599 lb down and 698 lb up at 5-9-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate lncrease=1.00 Uniform Loads (plf) Vert: 1-4=-10D, 5-8=-10 Concentrated Loads (lb) Vert: 6=-217 9=-217 1 0=-90(F) 11 =-217 12=-90(F) 13=-2689(F=-90, B=-2599) AWARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev, 1010312015 BEFORE USE. Design valid for use only with MiTek& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fa brication, storage, del ivery, erection a n cl b raci ng of tru sses a nd truss system s, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Infomnation available from Truss Plate Institute, 218 N. Lee Street, Sure 312, Alexandria, VA 22314. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FIL Cent 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C_TRAY T13452434 P2392ACT G1 MONO HIP 1 Job Reference (ootionah Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Mar 9 10:52:14 2018 Page 1 ID:ItiEj.2vqrkv4uEJUYC2jFzkFng-ONglrqUl7UYKgwNVgqcUbraKlUnjX28owjcWryzcgb? 2 5-11-4 111-411-`D 112 5-11-4 i 2-0-0 44 = 3 12 46X6 o 4x4 1.5X4 1.5x4 LOADfNG (p.f) SPACING- 2_D_0 CS1. TCL[ _ 20.0 Plate Grip DOL 1.25 TC 0.63 TCIDL 0 Lumber DOL 1 ' 25 BC 0.46 BCLL 0.0 R p Stress In cr YES WEI 0.60 BCIDL 10.0 Code FBC2017/TP12014 Matnx-MP LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. lb/size) 8=387/0-8-0, 10=280/0-1-8 Max Horz 8=187(LC 12) Max Uplift 8=-87(LC 12), 1 0=-1 30(LC 12) Max Grav 8=387(LC 1), 1 0=31 1 (LC 17) FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-8=-315/210 BOTCHORD 7-8=-256/151 WEBS 4-10=-316/266 3x4 10 DEFL. in (loc) I/defl L/d PLATES GRIP Vert(LL) 0.10 7-8 >963 240 MT20 244/190 Vert(CT) -0.20 7-8 >461 180 Horz(CT) 0.01 10 n/a n/a Scale = 1:28.5 Weight: 55 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 6=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Part. Encl., GCpi=0.55; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 6-0-0, Exterior(2) 6-0-0 to 7-6-12 zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 87 lb uplift at joint 8 and 130 lb uplift at joint 10. AwARN1NG - Verify design pammeters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473rev. 1010312015 BEFORE USE. Design valid for use only with ViTek(& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fa bricatio n, storag e, cl eivery, e rection and b racin g of trusses and I russ system s, see ANSIITPH Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. gRegan PE No,58126 MiTek USA, Inc. FL Cod 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452435 P2392ACT G2 MONO HIP 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Mar 9 10:52:14 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-ONglrqUi7UYKgwNVgqcUbc,aJvUooXI Uo*cWryzcgb? 1-0-12 4-74 7-11-4 1-0-12 4-7-4 34-0 4X4 6x8 MT20HS Scale = 1:24.8 3 12 4 8 1.5.4 11 4x4 = 1.5x4 H LOADING (pso SPACING- 2-0-0 CS1. TCLL 20.0 Plate Grip DOL 1.25 TC 0.66 TCDL 10.0 Lumber DOL 1 ' 25 BC 0.39 BCLL 0.0 Rep Stress Incr YES WEI 0.70 BCDL 10.0 Code FBC2017/TP12014 Matrix -MP 3x4 10 DEFL. in (loc) I/defl Ud PLATES GRIP Vert(LL) 0.15 7-8 >630 240 MT20 2441190 Vert(CT) -0.19 7-8 >480 180 MT20HS 187/143 Horz(CT) 0.02 10 n/a n/a LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BOTCHORD OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 8=387/0-8-0, 10=280/0-1-8 Max Horz 8=1 13(LC 12) Max Uplift 8=-1 05(LC 12), 1 0=-1 13(LC 12) Max Grav 8=387(LC 1), 10=297(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-8=-308/217 WEBS 4-10=-304/236 Weight: 50 lb FT = 20% Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Part. Encl., GCpi=0.55; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 4-8-0, Exterior(2) 4-8-0 to 7-6-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 10 considers parallel to grain value using ANSITTPI I angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 105 lb uplift at joint 8 and 113 lb uplift at joint 10. This item has been electronically signed and sealed by DRegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTok USA, Ina. F L Cott 6634 6904 Parke East Blvd. Tampa FL 3361 D Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekV connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY P2392ACT G3 COMMON 1 Job Reference footional) viia-rionaa LUmDer, tsanow, t-L. 4X6 10 9 s 6ep I b ZUI t Mi I eK Industries, Inc. Fri Mar 9 10:52:15 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-uaE72AVNuogB]4yhDY7j7q7YCuA5GcOy9NM400zcgb_ 3-8-0 4-34 . 1-0-12 4x4 = 6.00 F1_2 2 3x4 11 lX4 11 53X4 11 psf) SPACING- 2-0-0 CS1. LOADING TCLI _ 20.0 Plate Grip DOL 1.25 TC 0.43 TCDL 0.0 Lumber DOL 1.25 BC 0.26 BCLL 0.0 Rep Stress Incir YES WB 0.15 BCDL 10.0 Code FBC2017/TP12014 Matrix -MS DEFL. in (loc) I/defl Ud PLATES GRIP Vert(LL) -0.02 6 999 240 MT20 244/190 Vert(CT) -0.05 5-6 >999 180 Horz(CT) 0.00 5 n/a n1a LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BOTCHORD OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 5=387/0-8-0, 10=280/0-1-8 Max Horz 1 0=95(LC 11) Max Uplift 5=-130(LC 12), 10=-88(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 3-5=-310/294 WEBS 1-10=-292/226 Scale = 1:24.9 Weight: 38 lb FT = 20% Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft, L=24ft; eave=4ft; Cat. 11; Exp B; Part. Encl., GCpi=0.55; MWFRS (directional) and C-C Exterior(2) 0-5-4 to 6-8-0, Interion(l) 6-8-0 to 9-0-0 zone; end vertical right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 10 considers parallel to grain value using ANSITTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 130 lb uplift at joint 5 and 88 lb uplift at joint 10. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 3361D Date: March 9,2018 WARNING - V.dfyd..ignp....t— ar d READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FIL 36610 Job Type Qty Ply Park Sq/Barcelona-A or C—TRAYTrussTruss T13452437 P2392ACT G4 HIP 1 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 4X6 15 12 11 I I I 8.130 a Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:16 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-MmoVFV\(V?f6o2wDXtnFeyglgg_lVa?3g5Ol5dvrzcgaz 5-0-0 7-11-4 --0 _ 21-6 2-8-0 2-11-4 1 i9'—_-102 44 — 44 — 6. o o F1 _2 2 13 3 3x4 i '-4:' i 5- i 1 ':' __ - — ___8_Q'0 21-1 il:"I 2:1111 0 -12 Scale = 1:21.0 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in ioc) I/clefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) 0.06 7-8 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.07 7-8 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.15 Horz(CT) -0.00 6 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 40 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SID No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 6=424/0-8-0,12=323/0-1-8 Max Horz 12=-1 11 (LC 8) Max Uplift 6=-209(LC 8),12 177(1_C 8) Max Grav 6=425(LC 18), 12=324(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-260/184, 3-4=-281/173, 4-6=-329/186 WEBS 1-12=-338/189 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft, eave=4ft, Cat. 11; Exp B; Part. Encl., GCpi=0.55; MWFRS (directional); end vertical right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Dpsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 12 considers parallel to grain value using ANSIITPI I angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 12. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 209 lb uplift at joint 6 and 177 lb uplift at joint 12. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 65 lb down and 169 lb up at 2-4-0, and 9 lb down and 76 lb up at 3-8-0, and 65 lb down and 169 lb up at 5-0-0 on top chord, and 26 lb down and 27 lb up at 2-4-0, and 12 lb down and 13 lb up at 3-8-0, and 26 lb down and 27 lb up at 4-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (6). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-60, 2-3 60, 3-4=-60, 4-5=-60, 6-10=-20 Concentrated Loads (lb) Vert: 2=-18(F) 3=-18(F) 8=-14(F) 7=-14(F) 13=-9(F) 14=-8(F) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Ragan PE No.58126 MiTekUSA, Inc. FL Cort6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 WARNING - Verifyde.inIntrameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE IWII.7473 r— 1010312015 BEFORE USE. Design valid for use only with MtTelk(E) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq/Barcelona-A or C—TRAY T13452438 P2392ACT Hi MONO HIP 1 Job Reference (ontional) Mid -Florida Lumber, Bartow, FL. 1-0-0 1-0-0 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:17 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-qyMtTsWdOPwvXN64Lz9BDFCychvOkXrFchrARHzcgay 2-10-0 5-8-0 2-10-0 2-10-0 Scale= 1: 14.1 44 = 3x4 = 2X4 5 1.5X4 11 LOADING (psf) SPACING- 2-0-0 Csf. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate. Grip DOL 1.25 TC 0.12 Vert(LL) -0.00 6-9 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.10 Vert(CT) -0.01 6-9 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 5 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MP Weight: 27 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SIP No.2 TOPCHORD Structural wood sheathing directly applied or 5-8-0 oc purlins, BOTCHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=215/Mechanical, 2=286/0-3-8 Max Horz 2=73(LC 12) Max Uplift 5=-70(LC 9), 2=-93(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-256/134 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf, h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interlor(l) 2-0-0 to 2-10-0, Exterior(2) 2-10-0 to 5-6-4 zone;C-C for members and forces & MWIFIRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 5 and 93 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any. electronic copies. Philip J, O'Regan PE No.58126 MiTak USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FIL 3361D Date: March 9,2018 AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473— 1010312015 BEFORE USE. Design valid for use only with MiTelk(R) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Bel' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FIL 36610 Job T ss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452439 P2392ACT H2 COMMON 1 Job Reference fontional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:18 2018 Page I ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-18vGgCXFBj2m9XhGvggQIS17d5ERT.?fOrLakzjzcgax 2-10-0 5-M 68_9 1 2-10-0 2-10-0 1- 1 4x4 Scale= 1: 14.5 2x4 = 2x4 = i LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES GRIP 20.0 Plate Grip DOL 1.25 TC 0.10 Vert(LL) 0.00 5-8 - 999 240 MT20 244/190-.- TCLL TCDL 10.0 Lumber DOL 1.25 BC 0.15 Vert(CT) 0.01 5-8 999 180 BCLL 0.0 Rep Stress Incr NO WB 0.05 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP Weight: 22 lb FT = 20% LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. lb/size) 1=238/Mechanical, 3=309/0-3-8 Max Horz 1 =-36(LC 6) Max Uplift 1 =-71 (LC 8), 3=-1 22(LC 8) Max Grav 1=249(LC 17),3=316(LC 18) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-334/113, 2-3=-333/1 11 BOTCHORD 1-5=-66/277. 3-5=-66/277 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-8-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wrid: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=O.l 8; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 71 lb uplift at joint 1 and 122 lb uplift at joint 3. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 79 lb down and 170 lb up at 2-10-0 on top chord, and 26 lb down at 2-10-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plf]i Vert: 1-2=-60, 2-4=-60, 6-9=-20 Concentrated Loads (lb) Vert: 5=-26(F) 2-okr) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cort6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekOD connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCS] Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FIL 36610 Job Truss Truss Type - Q__ 1_ ty Ply Sq/Barcelona-A or C TRAY JPark T13452440 P2392ACT J2 JACK 1 1 01JJo, Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Mar 9 10:52:19 2018 Page 1 ID:ItiEL2vqrkv4uEJUYC2jFzkFng-mLTeuYYtylAdnhGSSOBflgHleVbrCSjY4?KHW9zogaw 1-0-0 2-10-0 1:61— 2-10-0 Scale = 1: 11.7 2x4 = LOADING (psf) SPACING- 2-0-0 CS1. TCLL 20.0 Plate Grip DOL 1.25 TC - 0.08 TCDL 10.0 Lumber DOL 1.25 BC 0.08 BCLL 0.0 Rep Stress Incr YES WEI 0.00 BCDL 10.0 Code FBC2017fTP12014 Matrix -MP LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=66/Mechanical, 2=182/0-3-8, 4=34/Mechanical Max Horz 2=75(LC 12) Max Uplift 3=-39(LC 12), 2=-61 (LC 12), 4=-1 (LC 9) Max Grav 3=77(LC 17), 2= 1 82(LC 1), 4=49(LC 3) FORCES. (1b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. DEFL. in loc) I/defl L/d PLATES GRIP Vert(ILL) 0.00 4-7 999 240 MT20 244/190- Vert(CT) 0.01 4-7 999 180 Horz(CT) 0.00 3 n/a n/a Weight: 11 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-10-0 oc purlins BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Part. Encl., GCpi=0.55; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 2-9-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 39 lb uplift at joint 3, 61 lb uplift at joint 2 and 1 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Ragan PE No.58126 MiTek USA, Inc. Fl. Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 9,2018 WARNING - Vfifyd..igmp.-0f.r. and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall WAN building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always re quired for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek' fabricalion, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPll Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C_jRAY T13452441 P2392ACT J3 JACK 3 Job Referen Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 M k Industries, Inc. Fri Mar 9 10:52:19 2018 Page I ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-mLTeuYYtylAdnhGSSOBfigHCtVYiCSjY4?KHw9zcgaw 2-11-4 2-11-4 Scale = 1:18.8 5 3x4 LOAIDING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d TCLL . 2D.0 Plate Grip.DCL 1.25 TC 0.45 Vert(LL) O 01 4-5 999 , 240 TCIDL 1 0.0 Lumberr DOL 1.25 BC 0.28 Vert(CT) 0.01 4-5 999 180 BCLI_ 0.0 Rep St ess Incr YES WB 0.00 Horz(CT) 0.04 3 n/a n/a BCDL 10.0 Code FBC2017rrP[2014 Matrix -MR LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BOTCHORD REACTIONS. (lb/size) 5=1 98/0-8-0, 3=66/Mechanical, 4=27/Mechanical Max Horz 5=127(LC 12) Max Uplift 5=-19(LC 12),3=-67(LC 12), 4=22(LC 12) Max Grav 5=198(LC 1), 3=89(LC 17),4=51(LC 3) FORCES. (lb) -Max, Corri Ten. -All forces 250 (lb) or less except when shown PLATES GRIP MT20 244/190 Weight: 13 lb FT = 20% Structural wood sheathing directly applied or 3-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf, BCDL=3.Opsf; h=15ft; B=45ft: L=24ft; eave=4ft; Cat. 11; Exp B; Part. Encl., GCpi=0.55; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 2-11-4 zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 19 lb uplift at joint 5, 67 lb uplift at joint 3 and 22 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 M!Tek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 WARNING -Verify designparamete,rs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTelk(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall ibuilding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sci/Barcelona-A or C—TRAY T13452442 P2392ACT J5 JACK 4 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 a Sep 15 2017 MiTek Industries, Inc. Fri Mar 9 10:52:20 2018 Page 1 ID:ItiEj_2vqrkv4uEJUYC2jFzkFng-EX1 05uYVIKITOrreD5juqtqPfvtCxvyhJf3q2czcgav 1:0- 5-0-0 16: 2, 5-0-0 2x4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/clefl Ud TCL[ _ 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) 0.04 4-7 999 240 TCDL 1 0.0 Lumberr DOL 1.25 BC 0.26 Vert(CT) 0.06 4-7 988 180 BCLL 0.0 Rep St ass Incr YES W13 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=127/Mechanical, 2=264/0-3-8, 4=64/Mechanical Max Horz 2=108(LC 12) Max Uplift 3=-64(LC 12), 2=-73(LC 12) Max Grav 3=127(LC 1), 2=264(LC 1), 4=91(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:17.0 PLATES GRIP MT20 244/190 Weight: 18 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10 Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., G pi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 4-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 64 lb uplift at joint 3 and 73 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: March 9,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473 rev, 1010312015 BEFORE USE. Design va lid for use only with MiTek(]D connectors. This design is based only upon parameters shown, and is for an individual build in g com pone nt, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall ibuilding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Mffak* s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Nexandna, VA 22314. Tampa, FL 36610 a Job Truss Truss Type Qty Ply Park Sq/Barcelona-A or C—TRAY T13452443 P2392ACT J7 JACK 17 Job Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 es, Inc. Fri Mar 9 10:52 20 2018 Page 1 ID:ItiEi_2vqrkv4uEJUYC2jFzkFng-EX105uYVjKITOrreO5juqtqKhvppxvyhJf3q2czcgav 1-0-0 . 7-0-0 3x4 4 Scale = 1:21.8 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) Ildefl - L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) 0.12 4-7 679 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.54 Vert(CT) 0.24 4-7 348 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 24 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=183/Mechanical, 2=342/0-3-8, 4=90/Mechanical Max Horz 2=141(LC 12) Max Uplift 3=-93(LC 12),2=-82(LC 12) Max Grav 3=183(LC 1), 2=342(LC 1), 4=129(LC 3) FORCES. (1b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 1 O-G-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 6-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 93 11b uplift at joint 3 and 82 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTak USA, Inc. FL Cart 6634 6904 Parke EaSt Blvd. Tampa FIL 33610 Date: March 9,2018 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(0) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must erify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Symbols PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y offsets are indicated. F-1 Dimensions are in ft-in-sixteenths. JL Apply plates to both sides of truss and fully embed teeth. 0-116" For 4 x 2 orientation, locate plates 0- 'lid' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate width measured perpendicular4x4toslots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 Of 0 0 F- Numbering System 6-4-8 1 dimensions shown in fl-in-sixteenths I(Drawings not to scale) 2 BOTTOM CHORDS 8 7 3 6 5 0of 0 a_ 0 I-_ JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1 311, ESR-1 352, ESR1 988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. 0 2012 MiTek@ All Rights Reserved A& General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1 . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I rac ng s ou e cons ere . 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSlrrPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSIITPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or after truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. I . a C zo A C 24" T- 4" 15'- 11 1/2" WALL < 21'- 0 1/2" 6'- 0" >< >< 5'- < T-0" F3 F5A 1 /4 G 0 vaC, F2 F5 1 LO i 0 F2 C C CJ311 F5 CNF- LL LL LL LL CJ5 F2 F5 J7 F2 F5 J7 F2 F5 J7 AF1 F12 F8 9'- 10 1/2" FT5 2-PLY r7 'q J7 F8 Eil F12 'd 5'- 4" F1 HGUS26-3 J7 r7 'q 0 t, 2 A F8 0 i 131 2-PLy F10 F73 3-PLY LL CJ5 rF1B22-PLY 0 2nd FLOOR WALL (C) z ED 1- F8 04 CJ3 F8A B3 2-PLY ILL LL LO Cl) 0 ri B4 3-PLY N 'q 71 'q P7 N F 'q f7 P, 9 F9 A Cli 0 CJ5 12'- 2" J3 F9 C 2 x 6 LEDGER BOTTOM AT 10'- 8 CJ3 OIL ILL LL ILL u- P, 8'-4" J3 F9 J3 Cl) LO D 04 D m C-9 D ciIP7 F9A 0 10'- 8 BRG. HGT. 12'- 8" LVL BM.'BOTTOM AT 9'- 4" 6'- 10 1/2" _1_ 9'- 4" —I—\ 10'-6" I NOTE: 2nd FLOOR OVER ENTRY CEILING AT 9'- 4" NOTE: SEE ENGINEERING PROFILES FOR SPECIAL CONNECTIONS AND NAILING SCHEDULES. FLOOR SPACING 24" O.C. UNLESS OTHERWISE NOTED. ALL WALLS SHOWN ARE LOAD BEARING AT 9'-4" UNLESS OTHERWISE NOTED. 11/0 1'- 7 3/4" HEEL FIRST FLOOR KLCUKU LUFY APPROVED TRUSS ANCHOR BY BUILDER BOTTOM =4x2 TOP = 4x2 2x4 Cont. Band v--,, TRUSS END DETAIL APPROVED TRUSS ANCHOR BY BUILDER PLUMB CUT OVERHANG HEEL HEIGHT= 2 x 4 0 i BOTTOM= 2x4 1 12TOP= 2x4 6.0 PPP' 0 1 8 - 4 5 5 2 A L, 23 - HHUS46 FLR. HGRS V 1 - HGUS26-3 3-PLY HGR S/ANPop D 4, 00 MID - FLORIDA LUMBER ACQUISITIONS T BARTOW, FLORIDA TRUSS LOADING CONDITIONS ROOF TRUSSES FLOOR TRUSSES TOP CHORD LIUE 200 TOP CHORD LIUE: 40.0 TOP CHORD DEAP: 100 TOP CHOU DEAD: 10,10 IBOTTOM CHORD DERR 100 BOTTOM CHORD DEAD 5.0 TOTAL LORO (PSF) 400 TOTHIL LORD (PSF) 55.0 STRESS INCRE9SE 1,25 , STRESS INCREASE: 1.0 THIS TRUSS SYSTEM HIAS BEEN DESIGNED WITH LORDS 5ENERRTED BY 140 MPH WINDS USING 42 ASP TOP CHORD DEAD LOAD AND 30 ASP BOTTOM CHORD DERD LOAD 0 MILES FROM HURRICANE OCEANLINE. CRT 11, EXP, 8 OSCE 7-10) BUILDER 2392 - A or C Park Square Homes LEGAL IDDRESS: 12" TRAY CLG. OPT. MODEL: Barcelona - A or C P2392ACT ISMLE TE NIA I" BNmByax7-21-171""' APPROVED TRUSS ANCHOR BY BUILDER BOTTOM =4x2 TOP = 4x2 2x4 Cont. Band 191/2" 24" 24" T- 0" —1— 19'- 11 1/4" 9'- 3" 8'- 0" 9 1/4" co U) 0 0 0 0 0 0 0 0 0 0 0 TRUSS END DETAIL CJ3CJ3T, APPROVED TRUSS ANCHOR BY BUILDER C%4 PLUMB CUT OVERHANG HEEL HEIGHT = 2 x 4 CJ5T J5 6 BOTTOM= 2x4 TOP= 2x4 12 6/12 6.0 F'r' J7T CJ3 O J7T zo F 6/12 0 I — 12'- 8" — I — 30'-2" —L— 9'-6" —1 NOTE: SEE ENGINEERING PROFILES FOR SPECIAL CONNECTIONS AND NAILING SCHEDULES. FLOOR SPACING 24" O.C. UNLESS OTHERWISE NOTED. ALL WALLS SHOWN ARE LOAD BEARING AT 9'-0" UNLESS OTHERWISE NOTED. J L 22-HUS26 1-PLYHGRC? 0 1 - HGUS26-2 2-PLY HGR SECOND FLOOR MID - FLORIDA LUMBER ACQUISITIONS BARTOW, FLORIDA TRUSS LOADING CONDITIONS ROOF TRUSSES I FLOOR TRUSSES TOP CHORD ILK: 200 ITOP CHORD LIUE: qOO TOP CHORD 10,0 BOTTOM CHORD DERD 100 1 BOTTOM CHORD DERD: 10 TOTHL LOHD (PSF) 400 ITOTHL LORD (PSF) 55.0 STRESS INCREHSE: 125 ISTRESS INCRERSE 1.0 THIS TRUSS SYSTEM HAS BEEN DESIGNED WITH LOADS GENERATED BY IqO MPH WINDS USIN5 q.2 PSF TOP CHORD DEAD LORD AND 10 PST BOTTOM CHORD DEAD LORD 0 MILES FROM HURRICANE OCERNLINE, CAT 11, EXP. A (ASCE 7-10) jPark Square Homes239:2 - A or C 1i rrpi Anrwz TRAY CLG. OPT. Barcelona - A or C P2392ACT 1 N/A 17'21-171 Bmax 00 copy City of Sanford Building and Fire Prevention Product Approval Specification Form Permit # 4 5 5 2 Project Location NG 'N O'F As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal) 1. Exterior Doors Swinging Therma - ru Single Door FI-8871.5 Sliding MI Windows and Doors Series 420 Alum SGID - 2 Panel FL 15332.4 Sectional Clopay Building Products 94/T40-W4 FLI 5279.20 Roll Up Automatic Other 2. Windows Single Hung MI Windows & Doors Series GA 185 Aluminum SH FL 17499.2 Horizontal Slider Casement Double Hung Fixed MI Windows & Doors Series GA 185 Alum Picture Fixed FL1 5349.1 Awning Pass Through Projected Mullions MI Windows & Doors 5764 Verical Alum Mullion FL 15353.2 Wind Breaker Dual Action Other June 2014 Category/ Subcategory Manufacturer Product Description Florida Approval # including decimal) 3. Panel Walls Siding James Harding Bldg Products Hardie Panel FL1 3223.2 Soffits Alpha Aluminum, Inc Coils Soffits FL16544.1 Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles IKO Industries, LTD Asphalt Shingles Cambridge FL7006.1 Underlayments Warrior Roofing 15 and #30 Roofing Felt FL2346.1 Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Categoryl Subcategory Manufacturer Product Description Florida Approval # include decimal) 5. Shutters Accordion Bahama Colonial Roll up Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signatu Applicant's Name Please Print) June 2014 Florida Building Code Online Page I ofC, BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff 5CIS Site Map Links Search Product Approval USER: Public Userdbr Product Approval Menu > Product or Application Search > Application Lis > Application Detail FL # FL8871-RB Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton, OH 43517 419) 298-1740 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan 3. King, P.E. W. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL8871 R8 COI (b) Certificate of Independence.pcif Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 2003 ASTM E1300 1998 ASTM E84 2000 ASTM G26 1995 TAS 201, 202, 203 1994 Florida Licensed Professional Engineer or Architect FL8871 R8 Equiv (b) Eguivalency of Standards.pdf http://www.floridabuilding.orcy/pr/pr_app dtl.aspx?para1n=wGEVXQMDqty-33 W nHrp... 2 102018I-D Florida Building Code Onlinez:1 Page 2 of 3) Sections from the Code Product Approval Method Method I Option D Date Submitted 10/17/2017 Date Validated 10/17/2017 Date Pending FBC Approval 10/19/2017 Date Approved 12/12/2017 of FL # Model, Number or Name 8871.1 a. "ClassicCraft Rustic" Series Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 8871.1 for Design Pressure Ratings by specific Model and for any other additional use limitations and installation instructions. Description 3'6 x 8'0 "Impact" Opaque Fiberglass Radius Top Single Door (X) - Inswing or Outswing Installation Instructions FL8871 RS II (b) Inst 8871.1.[)d Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL8871 R8 AE (b) Eval 8871.1.Ddf Created by Independent Third Party: Yes 8871.2 b. "ClassicCraft" or "ClassicCraft Rustic" Series T6 x 8'0 "Impact" Opaque Fiberglass Single Door (X) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 II (b) Inst 8871.2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.2 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.2.pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 8871.3 1 c. "ClassicCraft" or "ClassicCraft T6 x 8'0 "Impact" Opaque Fiberglass Single Door with Rustic" Series Sidelite (OX or XO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 (b) Inst 8871.3,r)d Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.3 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.3.pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For Fibei-Classic and SmoothStar sidelites, this product approval requires the use of "Y' part numbers for these sidelites, which have been stained or painted within six months of installation.) 1 8871.4 d. "ClassicCraft" or "ClassicCraft 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door with Rustic" Series Sidelites (OXO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 II (b) Inst 8871,4,i)df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.4 for Desion Pressure Ratings by FL8871 R8 AE (b) Eval 8871.4.[)df specific Model and for any-orther aiditional use limita-tions Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of "Y' part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871.5 7Seriese. "FiberClassic" or "SmoothStar" TO x 8'0 "Impact" Opaque Fiberglass Single Door (X) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 (b) Inst 8871.5.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.5 for Design Pressure Ratings by FL8871 RS AE (b) Eval 8871.5.r)df specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. I I http://www.floridabuildinc,.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqty') Wak2nHrp... 2/10/2018 Florida Building Code Online Page 3 of 3t=1 8871.6 f. "Fibel-Classic" or "SmoothStar" 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door withISeriesISidelite (OX or XO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 II (b) Inst 8871.6.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.6 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.6.1)df specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of "Y part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871.7 g. "FiberClassic" or "SmoothStar" Series 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door with Sidelites (OXO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 (b) Inst 8871.7.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.7 for Design Pressure Ratings by FL8871 R8 AE (b) Eval S871.7.pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of "Y' part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871.8 h. "FiberClassic", "SmoothStar", 6'0 x 8'0 "Impact" Opaque Fiberglass Double Door (XX) ClassicCraft" or "ClassicCraft Inswing or Outswing Rustic" Series Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL6871 R8 II W Inst 8871.8.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.8 for Design Pressure Ratings by FL8871 R8 AE (b) Eva[ S871.8.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 8871.9 i. "FiberClassic", "SmoothStar", 6'0 x 8'0 "Impact" Opaque Fiberglass Double Door with ClassicCraft" or "ClassicCraft Sidelites (OXXO) - Inswing or Outswing Rustic" Series Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 N Inst 8871.9.ipdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.9 for Design Pressure Ratings by FL8871 R8 AE W Eval 8871.9.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of 'T' part numbers for these sidelites, which have been stained or painted within six months of installation.) F - 7r Fl 7- t Contact Us :: 2601 Blair Stone Road, Tallahassee FL 3239 Phone: 850-487-182 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen Under Florida -law, email addresses are public records. If you do not want your -mail address released in response to a.public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . product Approval Accepts: M go R 0 t http://www.floridabuilding.orc,,,/p-r/-Dr p dtl.aspx?param=wGEVXQwtDqty3ljWak2nHrp... 2/10/2018ap _ 7 THERMANIRU ( a) THERMA TPIU 000P.S 1 1 E3 INDUSTRIAL DR., EDGERTON, 01-1 4351 7 SMOOTH STAR & FIBER CLASSIC FIBERGLASS SINGLE DOOR INSWING / OUTSWING 2ENERAL NQTES "IMPACT" I . This product has been evaluated and Is in compliance)A4th the 6th Edition (2017) Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVITthis product complies v.4th Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the "HVHZ" requiring wind bome debris protection, this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "U' and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1, 5. For 2k stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of this drawling require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations using coastal sill item 94 under active doors meet water Infiltration requirements for "HVHZ". 8. Inswing configurations and outswing configurations using sill item #5 under the door do not meet the water Infiltration requirements for the "HVHZ" and shall be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. TABLE OF CONTENTS SHEET # DESCRIPTION I I Typical elevations, design pressures & general notes 2 Door panel details (Smooth star) 3 Door panel details (Fiber classic) 4 Horizontof cross sections 5 Vertical cross sections 6 uckond frome - 2X buck masonry construction From anchoring - I X buck masonry construction 8 Bill of Materials S. Components 37.75" MAX. FRAME WIDTH 11,09, MAX ' _ 1PANELWIDTH T- x 6 J) 6z Pi EQV MILE':', DOOP:TY.O.E... Df 150 SMOOTH INSWING 37.75" x 98.00" 80.0 80.0 STAR OUTSWING 37.75" x 96.50" 80,0 80.0 INSWING 37.75" X Y&00" 80.0 80.0FIBER CLASSIC OUTSWING 37.75 x 96.50!' 80.0 80.0 See Sheet 8 for design. pressure limitations, t-i >6 UZ) 0 x 0z E. ol0 5 6 M a (L LA A J BY: Dws BY; LFS YING FL-8871.5 T I or 8 AA EXTERIOR i n n.- L DETAIL A -A J b' y,OORPANEI0" ,., 00000000000000000000000000000000000000000000000000000000000- 00000000000000000000000 000"00 000000000000000 0-,) 0.00 ' 1oE- - 0000000000000000000000000000000000000 10000000011 I L- 0-0, 1000-1- 0--o-0- 1 DETAILA-A Panel reinforcement HORIZONTAL CROSS SECTION 4.OZ' TYP. 4 1.53" CORNERS OF PANEL 1.53" cq E040 28.86% OPEN AREA MAX. NOTE: WOOD DOOR COMPONENTS: PINE (SG - 0.42) EXTERIOR 0z 11%, 0Z 0 0 0 0 r) ..z ON 0 Zo 0 Cw 6 0 (L X) 0CE INTERIOR VERTICAL CROSS SECTION2 C V) 0 E-- N.T.S. BY.. DWS BY.. LFS AnNG NO.: FL-8871.5 ET 2 OF _f EXTERIOR n INTERIOR rl-"\ HORIZONTAL CROSS SECTION 4.02" TYP. 4 CORNERS OF PANEL W. L DETAIL A -A J Iq OOR P NEI c' c'..,cFb.r 000000000000000000000000000000 00000000000000000000000 00000015 1.53" 000000000000000 66 A00000000 000 00000000a000000 00 0000000 000000000 0 00000 0 . 0 . 0 . 0 0 0 0 . 0 0000000 28.86% OPEN 000000000000000 AREA MAX. 00000000000000000000000 DETAIL A -A Panel reinforcement NOTE: WOOD DOOR COMPONENTS: PINE (SG >= 0.42) EXTERIOR no, z 4': 0 Z 0 'S, En .:2 0 00 0z 0 N a M, 2.: 6 EC11 'o t w on 5 6.00. 7 M 0- 0- C, LL E z Ln Lu C) z1 INTERIOR rz 0 0 VERTICAL CROSS SECTION SCAM N.T.S. DWG, BY: DWS CHK. BY: LFS DRAYnNG NO, FL-8871.5 sHEEr 3 OF —8 NZ 40 . p 0z 41: 0 Oin j. z If lot, 0 DD 0 0L) n z 0 z 0 z 8 INTERIOR Em P\ E a m . C; W5 0 m 0 C; z VC'd U1 2U4 3 4 EXTERIOR A zoH T E C) E I-IMMIN. D tmb. pyr.1 D 0 B 4 5 5 5 3 HORIZONTAL CROSS SECTION L Shown w/ I X sub -buck CLISI CSINK CSINK TYP.) TYP.) owg! U) z0 In 10 PRIM', INTERIOR INTERIOR m 77 ELIO- z z 12 124 40 EXTERIOR EXTERIOR DATE: O5Z22108 z 11 1-1/1V MIN. jj (:oI 60 14 C SCALE: N.T.S. DWG. BY: DWSEMB. (TYP.) E HORIZONTA L CROSS ACTION HORIZOr2 NTAL CROSS SECTIO 1-1/4'MIN, N- -BY-LFS DRAMS NO.: Oulswing shown - Inswing 0 tsvAng shown - insMnU EMB. (TYP.) also approved also approved FL-8871.5 0 E. 4 or N Q 12 2 Z EXTERIOR --//- INTERIOR VERTICAL CROSS SECTION Outswing shown - inswing also approved EXTERIOR INTERIOR VERTICAL CROSS SECTION lm w1ngcon1fgjure.'ti.n e g e. . sheet I for "HVHZ" water infiltration requirements z 4 4 44 EXTERIOR INTERIOR r2 " VERTICAL CROSS SECTION Shown w/lX sub -buck EXTERIOR INTERIOR rF VERTICAL CROSS SECTION lsnXAn'gn..,',1fgure.'ti.n g erc a sheet I for "HVHZ" water infiltration requirements N.G. 0:3 1 0 Z INTERIOR EXTEk"N z 0 ;; 6 0 " z 0 Z' 4. 0 0 5M40 09 (L IT z FE 10 5 60 0. O: A V) z 3 VER77CAL CROSS SECTION U t5 Outswing configuration see general notes, sheet I for "HVHZ" water infiltration 0requirements INTERIOR EXTERIOR VERTICAL CROSS SECTION conli u ionseegeneralnoFesroshee t I for "HVHZ" water infiltration requirements E: N.T.S. BY.. DWS BY.. LFS NING NO.: FL-8871.5 ET or TYP. HEAD & MASONRY 1AM11 OPENING d 2XBUCK--, BUCK ANCHORING CONCRETE ANCHOR NOTES: I . Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortarjoints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: 6" r! J) oz 0 5 Pf z 0. 0 n E L) N 0 - Z' 0T3M .0 TYP. HEAD & MASONRY a C0 0. JAMBS a) IL OPENING E cc A C FRAME-/ XZC) d 52 d 0 E 2X BUCK El ca 0 a c 0 n ED HINGEJAMB FRAME ANCHORING STRIKE JAMS Masonry 2X buck construction F I I I A . 1 N . c . 1 h 11 b I V: ANCHOR MIN. MIN CLEARANCE z MIN.CLEARANCE EMBEDMENT- TdMAsbNky..::: TO. ADJACENT EDGE, ANCHOR — ITIN TAPCONO 2" 4" ELCO JULTRACON 1/4" 1 1-1/4" ill 1 4" WOOD SCRE INSTALLATION NOTES: 1. Maintain a minimum 518" edge distance, I" end distance,& I"o.c. spacing of wood screws to prevent the splitting of wood. HINGE DETAIE LATCH & DEADBOLT DETAIL SCALE: N.T.S. DWG. BY. DWS CHX. BY.. LF-S DPAMNO NO.: FL-8871.5 SHEET _6_ OF_.L A1 NN, II u) En A c4 6z on Z 0 M 0TYP. HEAD JAMBS 0 n z Z. MASONRY OPENING 5 q 10- M tL a' 0I , WR: c,i Cj FRAME 15 N ZOE 03r At 0 I X BUCK 0 1 Qf CD 0 LATCH & DEADBOLT DETAIL iz LOU IT z0 HINGE JAMS STRIKEJAMB G-i CONCRETE ANCHOR NOTES: FRAMEANCHORING I . Concrete anchor locations at the comers may be adjusted to maintain the min. Masonry I X buck construction 12 edge distance to mortarjoints. 01 8 2. Concrete anchor locations noted as "MAX. ON CENTER"must be adjusted to (L CL 0- 2, Z) Z3 maintain the min. edge distance to morfarlornts, additional concrete anchors z m y be required to ensure the "MAX. ON CENTER" dimension are not exceeded. a Concrete anchor table: 3. 12 MIN. CLEARANCE-.: MIN. CLEARANCEANCHOR. ANCHOR t6:MASPNRY.-.%..: -TQ%ADJACEW-;. ZTYP&%*. -.SIZE..::. 4MBEbMENT. L zEDGE.::::,:, ANCHOR-.-, ITW J MTE: 5122108 z TAPCON 1/4" 1-1/4" 2- 4" SCALE. N.T.S. 1TW HINGE DETAIL TAPCON* 3/16- 1-1/4" 3- 1-1/2' IYWG. BY: OWS CHX. BY. LFS OD SCREW INSTALLATION NOTES: DPAMNO NO.: 1. Maintain a minimum 518" edge distance, l"enddistance, & I"o.c. spacing of wood screws to prevent the splitting of wood. FL-8871.5 00 SHEET OF BILL OF MATERIALS ITEM DESCRIPTION MATERIAL A I X BUCK SG >= 0.55 WOOD B 2X BUCK SG >= 0.55 WOOD C MAX. 1/4" SHIM SPACE WOOD D 114'X 2-3/4'PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI301ORHOLLOWBLOCKCONFORMINGTOASTMC90 CONCRETE G 3/16" X 3-1/4" PFH ITW CONCRETE SCREW STEEL 114'X 3-3/4" PFH ITW CONCRETE SCREW STEELJ L IOX2-1/2" PFH WOOD SCREW (1.15"MIN. EMBEDMENT) STEEL 1 INSWING ADJUSTABLE THRESHOLD (IS300AJ) ALUM./WOOD 2 INSWING THRESHOLD (IS300HP5) ALUM./COMP. 3 INSWING SELF ADJUST THERMAL BREAK THRESHOLD (ISP30M) ALUM./COMP ' 4 OUTSWING COASTAL THRESHOLD ALLIM./WOOD 5 OUTSWING STANDARD THRESHOLD ALUM./WOOD 6 INSWING THRESHOLD ALUM./COMP. 7 DOOR BOTTOM SWEEP VINYL 8 JAMB (PINE) SG >= 0.42 WOOD 9 JAMB (OAK) SG >= 0.42 WOOD 10 WEATHERSTRIP FOAM I I HINGE STEEL 12 If 10 X 3/4" PFH SCREW STEEL 13 9 X 3" PFH WOOD SCREW STEEL 14 LATCH STRIKE PLATE STEEL 15 SECURITY STRIKE PLATE STEEL 16 48 X 2-1/2" PFH SCREW STEEL 17 8 X 3/4" PFH SCREW STEEL 18 KWIKSET SERIES PASSAGE LOCK STEEL 19 KWIKSET SERIES DEADBOLT (660) STEEL 40 SMOOTH STAR DOOR - SEE DOOR PANEL DETAIL SHEET FOR DETAILS 41 DOOR SKIN 0.07Z'THK. (SMOOTH STAR) Fy = 6,000 PSI MIN. FIBERGLASS 42 TOP RAIL (SMOOTH STAR) COMP' 43 LOCK STILE (SMOOTH STAR) WOODAVL 44 HINGE STILE (SMOOTH STAR) WOOD 45 BOTTOM RAIL (SMOOTH STAR) COMP. 46 PANEL REINFORCEMENT 0.023' THK. (SMOOTH STAR) STEEL 47 FOAM CORE POLYURETHANE 60 FIBER CLASSIC DOOR - SEE DOOR PANEL DETAIL SHEET FOR DETAILS 61 DOOR SKIN 0.1 3T'THK. (FIBER CLASSIC) Fy = 6,ODO PSI MIN. FIBERGLASS 62 TOP RAIL (FIBER CLASSIC) COMP. 63 LOCK STILE (FIBER CLASSIC) WOODAVL 64 HINGE STILE (FIBER CLASSIC) WOOD 65 BOTTOM RAIL (FIBER CLASSIC) COMP. PANEL REINFORCEMENT 0.0237THK. (FIBER CLASSIC) STEEL 67 FOAM CORE POLYURETHANE o 4.56' HEAD & SIDE Jamb THRESHOLD Insviing adjustable r,"\ THRESHOLD InsvAng self -adjust 5.75' THRESHOLD Oulsvoing standard v., 6 CDi`cm I— — 5.85, fgi vp r,-11-T InsyAng adjustable 4.57' j>THREIHOID WE4n, c=11.1 r[ipinzi 11 i = W IshMW WE T lnsMng MAX. DESIGN PRESSURE 50 PSF] u) 0. 1- .2 0; n cS 6 0 n z a 10 0 6 o a - A, d 0 Z J c IV) CL co o CL JE: N.T.S. 13y: DWS BY: LFS VING No: FL-8871.5 r 8 OF 6 Flon*da Building Code Online Page I of 3DZ:1 5 M BCIS Home Log 1n User Registration Hot Topics Submit Surcharge Stats & Facts Publications i FBC Staff BCIS Site Map Links Search rProduct Approval USER: Public User Pmduct ADoroval Menu > Product or Application Search > Aoplication Lis > Application Detail FL # FL15332-R4 Application I ype Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Emoi.1 0 MI Windows and Doors 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Luis Roberto Lomas the Evaluation Report Florida License PE-62514 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Steven M. Urich, PE R Validation Checklist - Hardcopy Received Certificate of Independence FL15332 R4 COI FLCOI.pd Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2008 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D https://www.floridabuildina.orc, r/pr p dtl.aspx?param=wGEVXQwtDqtH8572qvd&qd... 2/1/2018 CD g/p _ap _ Florida Building Code Online Page 2 of Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products 08/11/2017 08/13/2017 06/15/2017 10/10/2017 FL # Model, Number or Name Description 15332.1 SERIES 420 ALUMINUM SGD SERIES 420 ALUMINUM SGD OXO 145-3/4"x80" NON - REINFORCED Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R4 11 08-00500E.Dd Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 R4 AE 510807D.od PRESSURE RATINGS Created by Independent Third Party: Yes 1 15332.2 SERIES 420 ALUMINUM SGD SERIES 420 ALUMINUM SGD OX, XO, XX 96"x80" NON - REINFORCED Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R4 11 08-00498E.pd Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 R4 AE 510805D.odf PRESSURE RATINGS Created by Independent Third Party: Yes 1 15332.3 SERIES 420 ALUMINUM SGD SERIES 420 ALUMINUM SGD REINFORCED OXO REINFORCED 145-3/4"x96" Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R4 II 08-02248C.rd - Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 R4 AE 512968C.Dd PRESSURE RATINGS Created by Independent Third Party: Yes 15332.4 SERIES 420 ALUMINUM SGD SERIES 420 ALUMINUM SGD REINFORCED OX, XO, XXIREINFORCED96"x96" Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R4 II 08-02249C.r)d Approved for use outside HV.HZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 R4 AE 512969C.Ddf' PRESSURE RATINGS Created by Independent Third Party: Yes 15332.5 SERIES 420 ALUMINUM SGD SERIES 420 ALUMINUM SGD REINFORCED XXX 143"x96" REINFORCED Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R4 11 08-02250C-pd Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 R4 AE 512970C.od PRESSURE RATINGS Created by Independent Third Party: Yes 1 15332.6 SERIES 420 REINFORCED SERIES 420 REINFORCED ALUMINUM SGD OX, XO, XX ALUMINUM SGD 96"x96" Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R4 11 08-00499E.Dd Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 R4 AE 510806D.od PRESSURE RATINGS Created by Independent Third Party: Yes I15332.7 SERIES 420 REINFORCED SERIES 420 REINFORCED ALUMINUM SGD OXO 146"x96" I ALUMINUM SGD I I Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Installation Instructions FL15332 R4 II 08-00501E.odf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports https://ww-w.floridabuild'mg.ora/pr/pr p dtl.aspx?param=wGEVXQwtDqtH8572qvdWId... 2/1/2018ap _ Florida Building Code Online Pacre 'D of') Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 R4 AE 5-',0808D.pd PRESSURE RATINGS Created by Independent Third Party: Yes 15332.8 SERIES 430/440 ALUMINUM SGD SERIES 430/440 ALUMINUM SGD XXX 143"x80" NON - REINFORCED Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R4 II 08-00502E.r)d Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62S14 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15337 R4 AE 510809D.Dd PRESSURE RATINGS Created by Independent Third Party: Yes rALUMINU'M 15332.9 SE S 430/440 REINFORCED SERIES 430/440 REINFORCED ALUMINUM SGD XXXL7RIEJSUMSGD143"x96" Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R4 H 08-00503E.od Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure; N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 R4 AE S10810D.Dd PRESSURE RATINGS Created by Independent Third Party: Yes Contact U :: 2601 Blair Stone Road, Tallahasse FL 32399 Phone, 850-487-182 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 4 55.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. Ho,vever email addresses -are pubAcre—co—rd. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M zo la-75-5 Ea 0 C1_ d C aI id Safe https://ww-w.floridabuildmc,.ora r/pr app_dtl.aspx?param=-AGEVXQw-tDqtH8572qvdWId... 2/1/2018P — NOTES: 1 . THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY' TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. IX BUCK OVER MASON RY/CONCRETE IS OPTIONAL. WHERE IX BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMIJRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4. ALLOWABLE STRESS INCREASE OF 113 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 5. FRAME MATERIAL: EXTRUDED ALUMINUM 6063—T5. 6. UNITS MUST BE GLAZED PER ASTM E1300-04/09 WITH SAFETY GLASS. 7. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 8. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. DOOR ASSEMBLIES INSTALLED WHERE OVERHANG RATIO IS EQUAL OR GREATER THAN 1.0 DO NOT REQUIRE WATER INFILTRATION RESISTANCE. OVERHANG RAT10 = OVERHANG LENGTH/OVERHANG HEIGHT 10. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 11. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1" MINIMUM EDGE DISTANCE. LOCATE ANCHORS A SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 12, FOR ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 13. ALL FASTENERS TO BE CORROSION RESISTANT. 14. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. C. MASONRY STRENGTH CONFORMANCE TO ASTM C-90. GRADE N, TYPE 1 (OR GREATER). D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 .048" THICK MINIMUM 15. APPROVED CONFIGURATIONS: OX, X0. XX, XP, PX, XIP, PIX TABLE OF CONTENTS SHEET NO. DESCRIPTION 1 NOTES 2 — 3 ELEVATIONS 4 — 10 INSTALLATION DETAILS REViSIONS REV DESCRIPTiON DATE APPROVED A ADDED FLANGE AND FIN INSTALLATION 12/10/13 R. L. B REVISED INSTALLATION DETAILS 08/03/15 R.L. C REVISED INSTALLATION DETAILS 06/21/17 R.L. SIGNED: 0612112017 MI WINDOWS AND DOORS LLC 0\tIIIII/// 650 WEST MARKET STREET 5 R L 0 I GRATZ, PA 17030 SERIES 420 SGD REINFORCED WITHOUT ADAPTER 96" X 96" NOTES TAT OF0r DRAWN: Tw REV V.L. 08-02249 C Luis R. Lomas P.E. FIL N 62514 SCALE NTS DATE 10/30/13 SNEET I OF 10 L. ROBERTO LOMAS P. E. 1432 WOODrORD RD LEWISVILLE, NC 27023 434-688-0609 11 ..... CDO--pex— 96" MAX FRAME WIDTH 2) ANCHORS PER LOCATION SEE CHART #3 FOR NUMBER OF LOCATIONS REQUIRED 6" MAX 17" MAX 1-r D.C. -1 - 6" MAX 6" MAX T-- I - 17" MAX O.C. 96" MAX FRAME HEIGHT I - 6" MAX SERIES 420 SGD REINFORCED WITHOUT ADAPTER EXTERIOR VIEW DESIGN PRESSURE RATING IMPA C T RA TING 35.OPSF NONE SEE CHA R TS # I AND #2 FOR 0 THER UNITS RA TINGS NOTES: 1. MAXIMUM PANEL SIZE: 48112"x 95 2. MAXIMUM D.L.O.:44 518"x90518" HARDWARE SCHEDULE FLAT MOUNTED HANDLE SET (99-04-145) AT 38 3/4" ON CENTER FROM PANEL BOTTOM METALLIC TANDEM ROLLERS (99-17-195) AT EACH END OF PANEL BO I -TOM RAILS JIVIINUM 6063-T6 REINFORCEMENT (668) ATALL PANEL INTERLOCKS CHART#1 WHERE WATER INFILTRATION RESISTANCE IS REQUIRED. SFF NnTr.Q.;NFFT I REVISIONS REV DESCRIPRON DATE APPROVED A ADDED FLANGE AND FIN INSTALLATION 12/10/13 R.L. B REVISED INSTALLATION DETAILS 08/03/15 R.L. C REVISED INSTALLATION DETAILS 06/21/17 R.L. Design pressure chatl (pso Fra,-no Single Panel and Total Frai-ne Width (in) Height 300 36.0 42.0 48.0 1 n) 60.00 p-o 72.00 84.00 96.00 s NegT- Pos Neg Pos Neg Pos Neg 84.0 40.0 58.4 40.00 50.9 40.0 45.7 40.0 42.0 88.0 0 40.0 1 55,2 040. 00EO. 48.0 40.0 430 39.4 39.4 9-2 40.0 1 52.4 4 -. 45.4 40.0 40.6 37.1 37.1 96.0 40.0 1 49.8 40.. 43.1 381.4 38.4 35.0 350 CHART#2 WHERE WATER INFILTRATION RESISTANCE IS NOT REQUIRED. SEE NOTE 9 SHEET I Design pressure chart (pso FraIne Single Panel and Total Franne VVIdth in) Height 30.0 36.0 1 4 .0 49.0 in) 60.00 72.00 84.00 96.00 Poe I Meg Nag P. Neg Pos Neg 84.0 58.4 58.4 Pos 50.9 50.9 45.7 45.7 1 42.0 1 42.0 88.0 55.2 1 55 2 48.0 48.0 43.0 43.0 1 39.4 1 39.4 92.0 6 52.4 1 52.4 45.4 31 45.4 40.6 4-D.-6T-3-7-1-F3-71 0 4981 49-8 4 3 -1 T8 4 38 435 0 35 0 CHARr#3 Ahnnbe, of anchor locations reqwred Fraim Single Panel and Total Fra Width (I n) Height 30.0 36,0 42.0 48.0 in) 60.0 72.0 84.0 91io H&S I Jamb H&S Jamb H&S Jamb S I jan1b 84.0 4 5 6 6 6 6 88.0 4 6 5 6 6 6 92.0 4 t66 5 6 6 6 96.0 1 4 6 5 6 6 6 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 420 SGD REINFORCED WITHOUT ADAPTER 96" X 96" ELEVATION DRA YN: DWG NO. R V. L. 08-02249 C SCALE NTS I-F 10/30/13 i I SHE" 2 OF 10 I. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-668-0609 tifoinasCaNdomaspe.com SIGNED: 0612112017 0 0 OFPAT 1 ONAL1110mm'\\ \ Luis R. Lomas P.E. FL No.: 62514 6" MAX — 11 6" MAX T- 1 17" MAX D.C. 96 11 MAX FRAME HEIGHT 6" MAX 96" MAX FRAME WIDTH 1) ANCHOR PER LOCATION AT HEAD & JAMBS SEE CHART #4 FOR NUMBER OF LOCATIONS REQUIRED 17" MAX 1—r 0 . C. 6" MAX 2) ANCHORS PER LOCATION SERIES 420 SGD REINFORCED WITHOUT ADAPTER AT SILL EXTERIOR VIEW SEE CHART #4 FOR NUMBER OF LOCATIONS DESIGN PRESSURE RATING IMPACTRATING REQUIRED 135.0PSF NONE SEE CHARTS #1 AND #2 SHEET2 FOR OTHER UN17-S RATINGS HARDWARE SCHEDULE FLATMOUNTED HANDLE SET(99-04-145)AT38 3/4"ON CENTER FROMPANEL BOTTOM METALLIC TANDEM ROLLERS (99-17-195) AT EACH END OF PANEL BOTTOM RAILS JIVINUM 6063-T6 REINFORCEMENT (668) AT ALL PANEL INTERLOCKS REVISIONS DESCRIPTION DATE PROVED ADDED FLANGE AND FIN INSTALLATION 12/10/13 R.L. REVISED INSTALLATION DETAILS 08/03/15 R.L. REVISED INSTALLATION DETAILS 06/21/17 R.L. NOTES: 1. MAXIMUM PANEL SIZE: 48 112"x 95" 2. MAXIMUM D.L.O.: 44 518"x 90 518" CHART" Number of anchor locations required Single Panel and Total Unit Width (in) Fraine Height 30.0 36.0 420 480 in) 60.0 7ZO 94 O 96.0 H&S I Janib H&S Ja b H&S Jamb I&S Ja 84.0 4 6 5 6 6 6 6 6 88.0 4 r 5 6 6 6 6 6 92.0 4 6 5 6 61 j 6 6 6 96.0 4 6 6 6 6 SIGNED: 0612112017 MI WINDOWS AND DOORS LLC 0NIIk-IiI1//j/ 650 WEST MARKET STREET GRATZ, PA 17030 E IV& f* 511SERIES420SGDREINFORCEDWITHOUTADAPTER 96" x 961, OFFINELEVATIONAT tT4; C) OR VD 'I' DRAWN: RD V. L. 249 C ONAC I/jIllw0 Luis R. Lomas P.E. 14TS DAII I 0/30/13 ISTIEFT3 or lo IL. ROUERTO LOMAS P.E. 1432 WOOOFORD RD LEWISVILLE, NC 27023 434-688-0609 rilomas@Irlomaspe.com FL No.: 62514 1/2" MIN. EDGE DISTANCE 1 3/8" MIN. WOOD FRAMING OR 2X BUCK EMBETMENT BY OTHERS 1/4" MAX. SHIM 10 WOOD SPACE SCREW EXTERIOR j I I I I I I I INTERIOR 10 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS SILL TO BE SET IN A BED OF APPROVED SEALANT MIN, IENT REVISIONS REV DESCRIPTION ATE APPROVED A ADDED FLANGE AND FIN INSTALLATION 12/10/13 R.L. B REVISED INSTALLATION DETAILS 08/03/15 R.L. C REVISED INSTALLATION DETAILS 06/21/17 R. L. 1 3/8" MIN. 114" MAX, EMBEDMENT SHIM SPACE 17— INTEROR 1/2" MIN. EDGE D ISTANCE I IF-1W==ikF1E]]ll 10 WOOD I SCREW EXTERIORIL—P— WOOD FRAMING JAMB INSTALLATION DETAIL OR 2X BUCK BY OTHERS WOOD FRAMING OR 2X BUCK INSTALLATION I_k 1/2" MIN. EDGE DISTANCE SIGNED: 0612112017 VERTICAL CROSS SECTION MI WINDOWS AND DOORS LLC WOOD FRAMING OR 2X BUCKINSTALLATION 650 WEST MARKET STREET N\ $ 9, L 0 GRATZ, PA 17030 C,. E IV & SERIES 420 SGD REINFORCED WITHOUT ADAPTER V 96" X 96" FRAME INSTALLATION DETAILS NOTES: DRAWN: EV Ic 4 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. V. L. T 7 08-02249 SCALE 0NAl- 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE NTS DAE 10/30/13 1 SHEI ET 4 OF 10 DESIGNED IN ACCORDANCE WITH ASTM E2112 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 Luis R. Lomas P.E. 434-688-0609 r1lomas@14omaspe.com FIL No.: 62514 1 1/2" MIN I" MIN. SEPARATION EDGE DISTANCE 1 1/4" MIN. 4 EMBEDMENT CONCRETE/ MASONRY BY OTHERS 1/4" MAX. SHIM SPACE OPTIONAL 1X BUCK TO BE PROPERLY SECURED SEE NOTE 3 SHEET 1 3/16" TAPCON 3/16" TAPCON MASONRY/ CONCRETE BY OTHERS EX TERIOn INTERIOR SILL TO BE SET IN A BED OF APPROVED SEALANT A A 1 1/4" MIN. EMBEDMENT 2 7/8" MIN 1" MIN. SEPARATION EDGE DISTANCE VERTICAL CROSS SECTION CONCRETEIMASONRYINSTALLATION REVISIONS REV DESCRIPTION DATE PPROVED A ADDED FLANGE AND FIN INSTALLATION 12/10/13 R.L. B REVISED INSTALLATION DETAILS OB/03/15 R.L. C REVISED INSTALLATION DETAILS 06/21/17 R.L. 1 1/4" MIN. EMBEDMENT T- /4" MAX. a SHIM SPACE MIN INTEF?IOR EDGE DISTANCE 3" MIN J SEPARATION El n A.' 3/16" TAPCON EXTERIOR CONCRETE/MASSONRY BY OTHERS JAMB INSTALLATION DETAIL CONCRETEIMASONRYINSTALLATFON OPTIONAL 1X BUCK TO BE PROPERLY SECURED SEE NOTE 3 SHEET 1 NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER ANO JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORbANCE WITH ASTM E2112 SIGNED: 0612112017 MI WINDOWS AND DOORS LLC 0,IIIIIII/// 650 WEST MARKET STREET GRATZ, PA 17030 E N SERIES 420 SGD REINFORCED WITHOUT ADAPTER " 65 1 *7 96" X 96" 0 0 F ',QFRAMEINSTALLATIONDETAILSTAT DRAWN: DWG NO, V. L. DATE 08-02249 TIC // Z//0NA`L SCALE NTS 10/30/1-) IsHrET6 OF 10 /0111110 L. ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, AC 27023 FIL No.: 62514434-588-0609 tIIomas@frIorj;aspe—m METAL STRUCTURE BY OTHERS 1/2" MIN EDGE DISTANCE 1/4" MAX. SHIM SPACE 10 SMS OR SELF DRILLING SCREW EXTERIOR I I I I I I I I INTERIOR SILL TO BE SET IN A BED OF APPROVED SEALANT 10 SMS OR SELF DRILLING SCREW METAL STRUCTURE BY OTHERS 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 T- 1/2" MI EDGE DISTI t 10 SMS OR SELF DRILLING SCREWS MErAL STRUCTURE BY OTHERS REASIONS REV DE CRIPTION DATE PPROVED A ADDED FLANGE AND FIN INSTALLATION 12/10/13 R.L. B REVISED INSTALLATION DETAILS 08/03/15 R.L. C REVISED INSTALLATION DETAILS 06/21/17 R. L. JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 0612112017 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 9 L o SERIES 420 SGD REINFORCED WITHOUT ADAPTER 96" x 96" FRAM E INSTALLATION DETAILS A . " A T4421' 1 z 0 MO` DRAWN: V. L. Dwc; No. 08-02249 EV C 10/30/13 1 SHEIT 5 OF 10rDMEL. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 4 -68834 -0609 Luis R. Lomas P.E. FIL No.: 62514 1/2' MIN. EDGE DISTANCE WOOD FRAMING 1 3/8" MIN. OR 2X BUCK EMBEDMENT BY OTHERS 1/4" MAX. SHIM SPACE 10 WOOD SCREWS EXTERIOR LL-U 11 11 INTERIOR 0 BE SET IN OF VED SEALANT 10 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS MIN. AENT VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INS TALLA TION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED INACCORDANCE WIT14ASTM E2112 1 3/8" MIN. EMBEDMENT T- i/2" MIN. EDGE DISTANCE 10 WOOD SCREWS WOOD FRAMING OR 2X BUCK BY OTHERS REVISIONS DESCRIPTION DATE APPROVED ADDED FLANGE AND FIN INSTALLATION 12/10/13 R.L. REVISED INSTALLATION DETAILS 08/03/15 R.L. REVISED INSTALLATION DETAILS 06/21/17 R.L. 1/4" MAX. SHIM SPACE JAMB INSTALLATIONDETAIL WOOD FRAMING OR 2X BUCK INSTALLATION SIGNED: 0612112017 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET 9 L GRATZ, PA 17030 SERIES 420 SGD REINFORCED WITHOUT ADAPTER 96" X 96" FLANGE INSTALLATION DETAILS TAT 0 F 0 RDRAWN: V. L. C l'/6NV- 00111110\\ Luis R. Lomas P.E. FDAIESCALENTS 10/30/13 jSRrET7 OF 10 L. ROBERTO LOMAS P.E. 1432 WOODFORORD LEWISVILLE, NC27023 434-680-0609 FL No.; 62514 1/2" MIN. EDGE DISTANCE METAL -- iSTRUCTURE BY OTHERS 10 SMS OR SELF DRILLING SCREW METAL STRUCTURE BY OTHERS EXTERIOR 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 1/4- MAX. SHIM SPACE 10 SMS OR SELF DRILLING SCREW lAwfiloyll, 1 TO BE SET IN BED OF PROVED SEALANT L- 1/2" MIN. EDGE DISTANC T- 10 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS nwilaNTM, REVISIONS REV DESCRIPTION DATE APPROVED A ADDED FLANGE AND FIN INSTALLATION 12/1 L. 8 REVISED INSTALLATION DETAILS R L. C REVISED INSTALLATION DETAILS 06/21/17 R.L. JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 0612112017 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET 11 L 0 GRATZ, PA 17030 E Nq .Lp SERIES 420 SGD REINFORCED WITHOUT ADAPTER 96" X 96" 4FLANGEINSTALLATIONDETAILS T49TAT OFOF DRAWN: V. L. 2249 tp ONAl- Luis R, Lomas P.E. CALE NTS 0/30/13 SFEET El OF 1010 L. ROBERTO LOMAS P.E. t432 WOODFORD RD LEWISIILIE, IC 21023 434-688-0609 r1lomas@Ifloniaspe c.M FIL No.: 62514 1 1/2" MIN. I" MIN. SEPARATION EDGE DISTANCE 1 1/4" MIN, EMBEDMENT CONCRETE/ MASONRY BY OTHERS 1/4" MAX. OPTIONAL SHIM SPACE 1X BUCK TO BE PROPERLY SECURED SEE NOTE 3 SHEET 1 3/16" TAPCON 3/16" TAPCON MASONRY/ CONCRETE BY OTHERS EXTERIOR LLU 11 11 INTERIOR SILL TO BE SET IN A BED OF APPROVED SEALANT REASIONS REV DESCRIPTION DATE APPROVED A ADDED FLANGE AND FIN INSTALLATION 12/10/13 R.L. B REVISED INSTALLATION DETAILS 08/03/15 R. L. C REVISED INSTALLATION DETAILS 06/21/17 R. L. 1 1/4" MIN. EMBEDMENT T- 1/4" MAX. SHIM SPACE M IN. EDGE DISTANCE 3" MIN. SEPARATION 3/16" TAPCON CONCRETE/MASONRY BY OTHERS INTERIOR U117 E, 3 11 HN EXTERIOR JAMB INSTALLATION DETAIL CONCRETEIMASONRY INSTALLATION OPTIONAL IX BUCK Ll TO BE PROPERLY SECURED SEE NOTE 3 SHEET I NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, MIA. 1 1/4 N NOT SHOWN FOR CLARITY. 4. EMBEDMENT 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 0612112017 MI WINDOWS AND DOORS LLC 2 7/13" MIN. SEPARATION 1" MIN. EDGE DISTANCE 650 WEST MARKET STREET GRATZ, PA '17030 9 L 0 VERTICAL CROSS SECTION SERIES 420 SGD REINFORCED WITHOUT ADAPTER CONCRETEIMASONRY INSTALLATION 96" X 96" 41, FLANGE INSTALLATION DETAILS A 6TAT: OF, DRAWN: DW13 NO, ZORVO V.L. 08-01 SCALE AL NTS I —E SHEET 910/30/13 OF 10 Illim L. ROBERTO LOMAS PE 1432 WOODFORD RD LEWISVILLE, NC 27023 Luis R. Lomas P.E. 434-688-0609 ilf—jasonrloinaspe.com FL No.: 62514 ul- -.. .1 BY OTHEF EMBE APPRO SEAU BEHIND ff8 WGULI SCREW APPROVED SEALANT BEHIND FIN 8 WOOD SCREW 7/16" MIN j EDGE DISTANCE EXTERIOR INTERIOR 1 1 1/4" MAX 7/16" MIN EDGE DISTANCE JAMB INSTALLATION DETAIL FRAMING OR 2X BUCK INSTALLATION 1 1/4" MIN. EMBEDMENT r WOOD RAMINGBYOTHERS INTERIOR TRIM 1/4" MAX. 1 3/8" MIN. SHIM SPACE EMBEDMENT HOOK STRIP F HOOK I STRIP plO SELF DRILLING 1 1), SCREW 10 WOOD PANEL SCREW EXTERIOR INTERLOCK EXTERIOR PANEL INTERLOCK HOOK STRIP INSTALLATION METAL STRUCTURE HOOK STRIP INSTALLATION SIGNED: 0612112017 2X BUCKIWOOD FRAMING REMSIONS REV D CRIPTION D APPROVED A ADDED FLANGE AND FIN INSTALLATION 12/10/13 R.L. B REVISED INSTALLATION DETAILS 08/03/15 R.L. C REVISED INSTALLATION DETAILS 06/21/17 R.L. 1 5/8" MIN. EDGE DIST. 4 A 1 1/4" MIN. INTERIOR EMBEDMENT MASONRY/CONC RE TE BY OTHERS Ix BUCK BY OTHERS, HOOK STRIP IX BUCK TO BE PROPERLY SECURED 3/16" EXTERIOR PANEL INTERLOCK HOOKSTRIP INSTALLATION MASONRYICONCRETE 1/2" MIN. METAL STRUCTURE 1/2" MIN. EDGE DISTANCE BY OTHERS EDGE DISTANCE TRIM INTERIOR VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION FOR SILL INSTALLATION SEE SHEETS 4-9. NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, IYOTH ERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TOBESTo DESIGNED IN A CCORDA NO E WITH A S TM E21L12 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 5 R - L 0 ENS 1 .*= 61 . — 4, ITAATI OF ZOM01 16NAL 1011111w Luis R. Lomas P. E. FIL No.: 62514 SERIES 420 SGD REINFORCED WITHOUT ADAPTER 96" X 96" NAILFIN & HOOK IMSTALLATION DETAILS DRAWN: V.L. 249 SCALE NTS 1-1 10/30/13 ISIIE-10 OF 10 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-6 8-0609 1110-01tiomaspe.com Florida Buildino, Code Online Page I of 6 BCIS Home Log In I User Registration Hot Topics Submit Surcharge Stats & Facts Publications FSC Staff BCIS Site Map Links Search Product Approvaldbg)r C, USER: Public User Product Approval Menu > Product or Application Search I Application Lis > Application Detail FL # FL15279-R5 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated reapply 11/28/17 0 Clopay Building Products Company 8585 Duke Blvd. Mason, OH 45040 513) 770-6062 mwesterfield@clopay.com Scott Hamilton shamilton@clopay.com Exterior Doors Sectional Exterior Door Assemblies Certification Mark or Listing Intertek Testing Services NA, Inc. Gary Pfuehler R Validation Checklist - Hardcopy Received. Standard Year ANSI/DASMA 108 2005 ANSI/DASMA 115 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 Florida Licensed Professional Engineer or Architect FL15279 R5 Eauiv 20170809 - FBC - DASMA 108 eouiv.odf FL15279 R5 Equiv 20170809 - FBC - DASMA 115 equiv.i)df Method 1 Option A 08/10/2017 11/29/2017 https:HvvN.floridabuildin-g.orcr/pr/pr app dtl.aspx?param=wGEVXQwtDqv')yVVKJZIQ... 2/1/2018 Florida Building Code Online Pac,e 2 of 6Z Date Pending FBC Approval Date Approved 12/05/2017 Summary of Products Go to Page = d a page i / 8 a 0 FL # Model, Number or Nam Description 15279.1 001 W3-09 DSIE-1A171: 2050, 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; 2051, 2053, 40SO, 4051, 4053, 62, interior skin 29 ga. min.) Single -Car (up to 9'0" wide) 64, 65, 62G, 62LG, 64G, SDP38, WINDCODE@ W3 Garage Door SFL38, SRP38, 134, 135, 136, 16130,6131,6133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proo of insDection.odfAlyprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W3 Listing Intertek.r)df Design Pressure: +20 PSF/-20 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 H 101655-Revl2.r)d windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBQ. Evaluation Reports Created by Independent Third Party: 15279.2 002 W3-09 DSIE-lA471: GD1SP, Gallery/Artistry/Expressions: 1-3/8" Double -skin Insulated GRISP, GD1LP, GR1LP, AR1SP, EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) AR1LP`, ED1SP, ED1LP, 4132, 2132, Single -Car (up to 9'0" wide) WINDCODE() W3 Garage Door 6132, SFC38, MFC38 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of insr)ectjon.lodApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W3 Listing Intertek.gd Design Pressure: +20 PSF/-21 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product OS/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 11 103952-Rev0l.i)d windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.3 003 W3 09 DSIU-1A171: 9130, Double -skin Insulated PUR (exterior skin 27 ga. min.; 9131, 9133, HDP13, HDPF13, interior skin 27 ga. min.) Single -Car (up to 9'0" wide) HDPL13, 7130, 7131, 7133, 8130, WINDCODE@ W3 Garage Door 8131, 8133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and [proof of insoection.pdApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W3 Listing Intertek.pd Design Pressure: +20 PSF/-20 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 II 104175-Rev01.pd windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports I Created by Independent Third Party: 15279.4 004 W3-16 DSIE-1A171: 2050, 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; 2051, 2053, 4050, 4051, 4053, 62, interior skin 29 ga. min.) Double -Car (9'2" to 16'0" wide) 64, 65, 62G, 62LG, 64G, SDP38, WINDCODE@ W3 Garage Door SFL38, SRP38, 134, 135, 136, 6130,6131t6133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of inspection,odApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W3 Listing Intertek.Ddf Design Pressure: +20 PSF/-21 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL1S279 R5 II 101820-Revl3.od windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.5 https://www.floridabuildincy.oralprlpr_app_dtl.aspx?param=wGEVXQwtDqv'yVVKJZI Q... 2/1/2018 Florida Building, Code Online Pacre of 6 005 W3-16 DSIE-lA471: GD1SP, GR1SP, GD11-P, GP,1LP, AR1SP, AR1LP, ED1SP, ED11-P, 4132, 2132, 6132, SFC38, MFC38 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Gallery/Artistry/Expressions: 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double -Car (9'2" up to 16'0" wide) WINDCODE@ W3 Garage Door Certification Agency Certificate FL15279 P,5 C CAC Letter with proof of contract and proo of insDec' tion. Qd FL15279 R5 C CAC W3 Listinq Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 II 104028-Rev0l.[)d Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.6 006 W3-16 DSIU_1A171: 9130, Double -skin Insulated PUR (exterior skin 27 ga. min.; 9131, 9133, HDP13, HDPF13, interior skin 27 ga. min.) Double -Car (9'2" to 16'0" wide) HDPL13, 7130, 7131, 7133, 8130, WINDCODE@ W3 Garage Door 8131, 8133 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant; N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of inspection.r)d FL15279 R5 C CAC W3 Listing Intertek.Qd Quality Assurance Contract Expiration Date OS/21/2028 Installation Instructions FL15279 R5 II 104168-RevOl.pd Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.7 007 W3-16 PAN-21`153: 73, 1500, Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) 75, 190, 84A, 94, 42, 48, 5S, 42B, WINDCODE@ W3 Garage Door 48B,55S,4RST,6RST,4RSF,6RSF Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and oroof of inspection.r)d FL15279 R5 C CAC W3 Listing Intertek.j)df Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 II 101308-Revl2.fpd Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.8 008 W4-09 DSIE-11`171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201,6203 2" Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODE@ W4 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1 5279 R5 C CAC Letter with proof of contract and proo of inspection.pdApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL15279 R5 C CAC W4 Listing Intertek.odf Design Pressure: +28 PSF/-29 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 RS 11 101652-B-Revll.pdf windborne debris regions. The product without glazing DO -ES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.9 009 W4-09 DSIE-11`471: GD2SP, GR2SP, GD2LP, GR21_P, AR2SP, AR2LP, ED2SP, ED2LP, 4302, HDGC, 6202, SFC68, MFC68 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28 PSF/-29 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but Gallery/Artistry/Expressions: 2" Double -skin Insulated EPS exterior skin 27 ga. min.; interior skin 27 ga. min.) Single - Car (up to 9'0" wide) WINDCODE@ W4 Garage Door Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proo of inspection.pd FL15279 R5 C CAC W4 Listing Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 II 103969-B-RevO2.1)d https://www.floridabuilding.oro,/pr/Pr p dtl.aspx?param wGEVXQwtDqv'yVVKJZlQ... 2/1/2018C) _ap _ -1 Florida Buildinor Code Online Page 4 of 6 DOES NOT meet the impact resistant requirement for Verified By: Intertek Testing Services NA, Inc. windborne debris regions. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.10 010 W4-09 DSIU - 11`171: 9200, Double -skin Insulated PUP, (exterior skin 27 ga. min.; 9201, 9203, HDP20, HDPF20, interior skin 27 ga. min.) Single -Car (up to 9'0" wide) HDPL20, 7200, 7201, 7203, 8200, WINDCODE@ W4 Garage Door 8201,8203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of inspection.od FL15279 R5 C CAC W4 Listing Injertek.df Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL1527q R5 II 104183-Rev0l.pd Verified By: InterLek Testing -Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.11 011 W4_09 DSIUO-IK479: Canyon Double Skin Insulated PUR (exterior skin 27 ga. min.; Ridge/Brookstone interior skin 27ga. min.) with Overlay Single -Car (up to 9'0" I wide) WINDCODE(D W4 Garage Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +28 PSF/-29 PSF Other* The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and oroof of insl)ection.pd . FL15279 R5 C CAC W4 Listing Intertek.od Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 R5 II 104456-RevOl.r)d Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.12 012 W4-09 PAN-21`151: 73, 1500, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 75, 190, 84A, 94, 76, 42, 48, 55, WINDCODE@ W4 Garage Door 42B, 48B, 55S, 4RST, 6RST, 4RSF, 6RSF, 2RST, GD5S, GD5SV, GRSS, GRSSV,AR5S,AR5SV,ED5S, EDSSV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. 15279.13 013 W4-09 PAN-21`441: G4S, GS4, G4L, GL4, GD4S, GD4L, GP4S, GR4L, G4SV, GS4V, G4LV, GL4V, GD4SV, GD4LV, GR4SV, GR4LV, E4S, E4L, ED4S, ED4L, E4SV, E4LV, ED4SV, ED4LV, SS4, SL4, AR4S, AR4L, SS414 SL4V, ARASV, AR4LV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other. The standard glazing available for this product meets the wind load requirements of the.building code but DOES NOT meet the impact resistant requirement for windborne debris regions. Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and oroof of ins ection.Ddf FL15279 R5 C CAC W4 Listing Intertek,odf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 II 300159-B-Rev16.nd Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Single - Car (up to 9'0" wide) WINDCODE@ W4 Garage Door Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of inspection.l)d FL15279 R5 C CAC W4 Listing IQ ek. Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15?79 RS II 103486-B-RevO8.od Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.14 014 W4-09 SPO-21`449: Grand Steel Pan (min. 24 ga.) with Overlay Single -Car (up toIHarbor, Stone Manor 9'0"wide) WINDCODE@ W4 Garage Door https://www.floridabuilding.orc,/Pr/pi_app_dtl.aspx?param=wGEVXQwtDqv' )yVVKJZIQ... 2/1/2018 Flon'da Buildinc, Code Online1 Pac,e 5 of 6 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-32 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FEC). Certification Agency Certificate FL15279 P,5 C CAC Letter with oroof of contract and oroof of inspection.od FL15279 R5 C CAC W4 Listing Intertek.Ddf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 II 103549-RevO6.odf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.15 015 W4-16 DSIE-1F171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201,6203 2" Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double -Car (9'2" to 16'0" wide) WINDCODE5 W4 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract an.d-pLoof of inspection.1)dApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL15279 R5 C CAC W4 Listing Intertek.odf Design Pressure: +25.5 PSF/-25.5 PSF Quality Assurance Contract Expiration Date Other: The standard glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 11 101481-B-Rev13.Pd windborne debris regions. Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party; Evaluation Reports Created by Independent Third Party: 15279.16 016 W4-16 DSIE-1F471: GD2SP, Gallery/Artistry/Expressions: 2" Double -skin Insulated EPS GR2SP, GD2LP, GR2LP, AR2SP, exterior skin 27 ga. min.; interior skin 27 ga. min.) Double- Alk2LP, ED2SP, ED2LP, 4302, Car (9'2" up to 16'0" wide) WINDCODE@ W4 Garage Door HDGC, 6202, SFC68, MFC68 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of insoection.odApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL15279 R5 C CAC W4 Listing Intertek,pdf Design Pressure: +25.5 PSF/-25.S PSF Quality Assurance Contract Expiration Date Other: The standard glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 11 104029-6-RevQ3.odf windborne debris regions. Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.17 017 W4-16 DSIEO-11`479: Double Skin Insulated EPS (exte ior skin 27 ga. min.; Coachman/Settlers/Affinity interior skin 27ga. min.) with Overlay Double -.Car (up to 16'0" wide) WINDCODE@ W4 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of inspection.pdApprovedforuseoutsideHVHZ. Yes Impact Resistant: N/A FL15279 R5 C CAC W4 Listino Intertek.l)df Design Pressure: +25 PSF/-25 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 II 103046-RevO7.pd windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports I Created by Independent Third Party: 15279.18 o18 w4-16 DSIU-11`171: 9200, Double -skin Insulated PUR (exterior skin 27 ga. min.; 9201, 9203, HDP20, HDPF20, interior skin 27 ga. min.) Double -Car (9'2" to 16'0" wide) HDPL20, 7200, 7201, 7203, 8200, WINDCODE@ W4 Garage Door 8201,8203 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1S279 R5 C CAC Letter with proof of contract and proof of inspection. pdApprovedforuseoutsideHVHZ: Yes.. Impact Resistant: N/A FL15279 R5 C CAC W4 Listing Intertek.pdf Design Pressure: +25.5 PSF/-25.5 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 RS II 104169-Rev0l.l)d windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC), Evaluation Reports Created by Independent Third Party: https://www.floridabuildina.orc, r' r app dtl.as x?param=wGEVXQwtDqv3)yVVKJZlQ... 2/1/2018P /P - - - - P Florida Building Code Online Page 6 of 6 15279.19 019 W4-16 DSIUO-lK479: Canyon Double Skin Insulated PUR (exterior skin 27 ga. min.; Ridge/Brookstone interior skin 27ga. min.) with Overlay Double -Car (9'2" to116'0" wide) WINDCODE@ W4 Garage Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25.5 PSF/-25.5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.20 020 W4-16 PAN-21`153: 73, 1500, 75, 190, 84A, 94, 42, 48, 55, 4RST, 6RST, 4RSF, 6RSF, GD5S, GD5SV,GRSS,GR5SV,AR5S, ARSSV,ED5S,EDSSV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24 PSF/-24.5 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. Go to Page = d Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of inspection,pd FL15279 R5 C CAC W4 Listina Intertek.pd Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 II 104457-RevO2.pd Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) WINDCODE@-W4 Garage Door Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of inspection, Did FL15279 RS C CAC W4 Listing Intertek.cicif Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279- R5 II 101711-B-Rev15.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: E-E FN__1j Page 1 / 8 Contact Us :: 2601 Blair Store Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an WEED employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Staitemen :: pef.nd Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487. 1395. -Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . , Product Approval Accepts: 0 45E Fa_iRl R 0 Cfed-"t carb Safe https://www.floridabulldlno,.ora/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv' )yVVKJZIQ... 2/1/2018 1 1., DOOR HEIGHT Ta TV 7'Y TO P/111 11101 fi/1 III III Y/ P/ C DE13R VIM Ile, To 9101 T. 11— SME TAME MR OTY). T,r.L-Lmgp V%) NO A "--T ` HYERVBXAT, 6"" ly, I I S, 71w 11 r7: 17 11 r, I A DOOR WIDTH - I§*-0" CLASS& SHORT SIXAMN. 'CAR "0Uw SHORT RVSDD_PAREL is ALSO 1144/5* SHEET7EFALSCREWS VA 41114;j— RERS v m_ W SEE SHEET TWO FOR IMPACT RESISTANT CONSTRUCTION DETAIL "A" AND STANDARD CONSTRUC'T DETAIL "B"; TRACK AND JAMB DETAILS. SHEET 1 OF 2 OPTIONAL GLAZING MAY BE STANDARD OR IMPACT RESISTANT GLAZING. SEE SECTION B-B FOR DETAILS. MAX. STANDARD SIZE IS 42-1/2"06". IMPACT RESISTANT GLAZING IS 211-5/8%14-1/8*. a* . 20 C& U-. U-BARS IN A 2-1-2-1 1AT=.%E,A.U,-- ONE U-BARS ON 67 socroH. ETC) VIEW v OWN 11MMI I [ 1W5`71 DESIGN ENGINEER: MARK WESTERFIELD. P.E. FLORIDA P.E. 10495. NO P.E. #23832, TEXAS P.E. #91513 DATE DESCRIPTION 3/07 ADDED EXTENDED H8GHffS, COMBINED CLOI 1/08 ADDED M/N 42B. 48B. 55S 1/00 ADDED M/N 4F 30 ADDED 'CARRIAGE HOUSE' EMBOSS DOORS. 10 UPDATED MODEL TABLE. 12 REVISED WIND SPEED TA13LE FOR ASCE7-1 12 ADDED IMPACT RESISrANT OPTION. VIEW W LOCH POS1710" SCfS) M PONT LCCKING SHIP LAP JOINTS. - 10 DENSITY POLYSTYRENE FOAM INSULATION 1-5/16- THICK WITH VINYL HAIRCELL BACKER (INSULATED MODELS ONLY) 25 GA. MIN. GALV. STEEL SKIN WITH A BAKED -ON PRIMER, AND A RAKED -ON POLYESTER TOP COAT APPLIED TO BOTH SIDES OF STEEL SKIN. W- THE *`B- C,XX ( w mm.. 25)F 3) ANT IKff A -XDgn2. PR x. TE KTEGCRY I.- C. -I.- C SECTION A -A (SIDE VIOL I T- 2' THICK M ' —'rW.`;A-2F11 3 DATE- 1/3/97 8585 DUKE BLVD. MRAVN BY, Building Products MASON ' OH 45040 JAC Company (513) 770-4800 CHECNED BY, Ctop.y CorpomtIon All RIghb R—md. mww OPROW&L 15279 AND IDEAL 3" TALL U-BAR 20 GA, DALY. STEEL MIN. YEILD STRENGTH: 50 KSI C1 3' 1-7/1' =j T 1 2 GA. GALV. STEEL TOP ROLLER BRACKET. EACH BRACKET ATTACHED W/(4) 0144/8- SHEET METAL SCREWS. 14 GA_ GALV. ROLLER HINGE. EACH HINGE FASTENED TO END STILES WITH (4) #140/8" SHEET METAL SCREWS AND (4) 1/4".3/4 " SELF TAPPING SCREWS. SEE VIEW W. 3 1 3' TALL . 20 GA_ GALV. STEEL U-SARS IN A 2-1-2-1 PATTERN (I.E. TWO U-BARS ON BOTTOM SECTION, ONE U-BAR ON NEXT 3 SECTION, ETC.). EACH U-BAR ATTACHED WITH (2) 1/4.3/4* SELF TAPPING SCREWS PER SnLE LOCATION. 13 GA. GALV. STEEL BOTTOM BRACKET. ATTACHED WITH (2) #145/8" SHEET METAL SCREWS, ALUMINUM EXTRUSION VINYL WEATHERSTRIP. DESIGN LOADS: +24.0 PSF & -24.5 PSF TEST LOADS: +38.0 PSF & -37.0 PSF VV4 n RATING I MA . DOEIR SIZE- W4 16'O"W x 16'0"H FESCRIPTION, CLASSIC AND CH RP STEEL PAN DOUBLE -CAR, 16'W +24/-24.5 PSF ER, 101711 KDOOL is H TARPIAGE HOUSE' RAISElI PANEL. Emmums Dom HUDE1.3 25 GA 125 GA INS CLOPAY ov5s, w5lv, GIM OR3SV ART's AR3sv DEAL TARRlAGE HOUSE. ms a3sv DIM MONT S41"L 0 OF U-BARIJ UP TO 7'V40 " 7'3' TO 6'W7 45 MUT OT zxi TO PROVIDE A nUSH TOI' TO 10-6 6 9 SURRACE. HORD'ONT& "m DO NOT' TRANSW, LOAD. I.' M 12-3M 77ITO6- TO 14 f- L r I, 4-31 TO L& 8 gr —0 — w cENTENm, m000 m Omamm I 6'0' INCLUDED S.EEVE%CWRS. OR KAX Imnum WFM 17- CENTERS (2.000 PID MIN' CONCRETE) OR 9- CENTERS ). V .0. REVURED WITH TAPCONS. ANCHORS NAY BE C"I"ERSURK J:T NOT EWQLA=PROWE A FLUSH G SURFACE. HORIZONTAL W DO LOAD. RE`ER TOREFER TO 'IDS-15t. A LICENSED DEUGH Y ALSO BE IN TO APPROVE ALIMNATE FASTENERS to STOP moutImsto is — iNsIALLER cm sum w PIKE W_ Mll — STEEL END STILE MV STIOD. INTER. SIXE— IMPACT RESISTANT ASSEMBLY DETAILS D RAWING 101711 _A SECTION B—B IMPACT —RESISTANT GLAZING OPTION) OPTIONAL DECORATIVE SHNI'm NSUff. l—'T rACADE. CN,ANT TISTEEL am AND FRAUD. NPACT RURDANT w-P,`C[ N TO 10) #8 3/4- M HEN) LIACHINE $00— i'RONT 2600. STANDARD ASSEMBLY DETAJLS DRAVAPAr. 10 171 1 -B TRW FRALIE WITH U.V. 000UINO ON OUTSIDE SURFACE NOTE THAT E 5 NARRO M THAN WACT RESISTANT E. D'O7D MCE LITE RETAINER. RUCTION LITES AVALA RE OPM OR LUCITE OP APPROVED = PLASM IN ACCORDANCE WITH ISC/M 2M. THE ENTIRE DOOR ASS y INSTALLED IN C E WITH TH SECTION THE WRID LOAD REOUIRELINTS OF THE FLORIDA BUILDING CODE OR 114TERRAMNAL BUILDING CODE OUT DW,= WEET 'ME WACr RESISTANT REQUIREWIM WDOORNE DEEM REQUINS W cNAPTIER 1. FRC,4m). SHEET 2 0 Is OX OAl2v. HRm EACH ER I"'HOE FASTENED TO STAEs, ONE PER RUM) 2 V. STEEL, TRACK FASTENED To 14 DA. DALX ROLLER —E. EACH —9 0 ABOVE THE DOOR OPENINGSELl' TAPPIND SCRIER3. DOES NOT AFFECT THE WIND RALL. SHORT STO,I STIED. RDI-I.Ell WITH LOAD RATING OF THIS DOOR. 2 GA. V 37— TRACK BiRAC FASTENED TO END SOLES WITH (4) NOTE, TRACK CONFIGURATION 4Fj%E I'l -114-1— — — — ( OIRON "ORDONTAI, TRACK Suf BY NYLON TIRE DOOR 8' TALL DiXM AND UNDER HM THE DESIGN Or THE SUPPORTING SIR O SHAUL BE TIVE 13 GA. MV STEEL nAQ ERADKET R TOP BRACKET RE"MMILRY THE PROFESSIONAL OF ADCORD FOR THE K*-DM OR EACH FAStD*D M WOOD AM RITH DOUBLE HORIZONTAL STRUCTURE AND IN A00OR CE WON CURRENT INALOING CODES THE LOAD$ (3) 5118.1-5le WOCID LAD SCRE TRACKLISTEDONTHEDRAW". 2' DAM STEEL TRACMINLTRACKTHICKNESS; 0.* TVP' 2-.1/2*.12 GA. GALV. STEEL TRACK ORAGI,ET. 4) TRACK BRACI(M PER SIM ACI 31 TRACK AvAll—, ASLHEEDED. NORD'ONTAL TRACK SUPPORT DOORS OVER a' TALL , visr (TO sun) L13 OA. GALV. STEEL EIRACKEl'. F 77 " -T- EACH FASTENED M wow 4AWS WITH L3) 5116.0-51r LAD SCFWWL Fm --- I gTV23? DALY. GROB. TRACIEELT K* TRACK ._ . 'KGMESS Oao am ENGINEER: MARK WESTERFIaD, NOT TO "GEEO 30' O.C. TY') U WL FOR DOM OVER t2'-D- HIGH, TTWK CONMU N SHALL NOT EXCEED IWVOUW SPACING FOR IAORE DETAA- F ROO. DESIGN LOADS: +24.0 PSF 81 —24.5 PSF Florida Building Code Online Pac,e 1 of 4 1 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map i Links Search Approval W. r USER: Public Userdb Product Approval Menu > Product or Application Search > Application Lis > Application Detail FL # FL17499-R3 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary, Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich, PE 2 Validation Checklist - Harccopy Received Referenced Standard and Year (of Standard) Standard AAMA506 AAMA/WDMA/CSA 101/I.S.2/A440 AAMA/WDMA/CSA 101/I.S.2/A440 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 01/15/2018 Date Validated 01/15/2018 Date Pending FBC Approval Date Approved 01/21/2018 Year 2011 2008 2011 https://www.floridabuild'mc,.orc-,/pr/pr p dtl.aspx?param==wGEVXQwtDqtCUGovjQiz6B... 2/1/2018ap Florida Building Code OnlineZD Page 2 of 4 Summary of Products FL # E-de:l:, Number or Name Description 17499.1 185 SH 36x84 Fin/Flange Frame IG/SG Impact Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC MI Windows - 185 SH (Fin) Impac 4)-odApprovedforuseoutsideHVHZ: Yes Impact Resistant: Yes FL17499 PQ C CAC MI Windows - 185 SH (Fin) Imoact (5) Done.1)dDesignPressure: +55/-55 Other: R-PG55*, Missile Level D, Wind Zone 3. Glass to be FL17499 R3 C CAC MI Windows - 185 SH (Flange) Imoac 3).odbeddedinPecora896sealant. FL17499 R3 C CAC MI Windows - 185 SH (Flanoe) Impact 4).Dd Quality Assurance Contract Expiration Date 10/17/2018 Installation Instructions FL17499 R3 II 08-025458j)d Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513321B-3.pd Created by Independent Third Party: Yes 17499.2 1185 SH 52x72 Fin/Flange Frame IG/SG Single Hung Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC APC(13361)El726,01-109-47-RO 185 SH(FLG waiver).odApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL17499 R3 C CAC MI Windows - 185 SH (Fin) (11).jodf FL17499 R3 C CAC MI Windows - 185 SH (Fin) (12).DdDesignPressure: +60/-60 FL17499 R3 C CAC MI Windows - 185 SH (Flange) Other: R-PG60 10).od Quality Assurame Contract Ex—piFation Date- 10/08/2018 Installation Instructions FL17499 R3 II 08-02549B.pd Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513327B-4.r)d Created by Independent Third Party: Yes t18517499.3 SH 736x84 Fn/Flange Frame IG/SG Single Hung Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC APC(13363)El729.01-109-47-RO 185 SH (FLG waiver).r)dfApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL17499 R3 C CAC MI WindoWs - 185 SH (Fin) (13).Dd FL17499 R3 C CAC MI Windows - 185 SH (Fin) (14),I)dDesignPressure: +60/-60 FL17499 R3 C CAC MI Windows - 185 SH (Flanoe) Other: R-PG60* 11). [:)d Quality Assurance Contract Expiration Date 10/17/2018 Installation Instructions FL17499 R3 II 08-02550B.od Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513328B-5.lpd Created by Independent Third Party: Yes 17499.4 18S SH 36x7l Fin, Finless, Flange Frame IG Single Hung Limits of Use Certification Agency Certificate Approved for use in KVHZ: No FL17499 R3 C CAC APC H0462.01-109-47-RO 185 SH 042522).odApprovedforuseoutsideHVHZ: Yes Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +60/-67 04/25/2022 Other: R-PG60* Installation Instructions FL17499 R3 II 08-03163jod Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 514082.Qd Created by Independent Third Party: Yes 17499.5 185 SH 152x72 Fin/Flange Frame IG/SG Impact Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC MI Windows - 185 SH (Fin) Impac 2). pdApprovedforuseoutsideHVHZ: Yes Impact Resistant: Yes FL17499 R3 C CAC MI Windows - 185 SH (Fin) Impa https://www.floridabuildinc,.org/pr/pr app dtl.aspx?pararn=wGEVXQwtDqtCUGc, Qiz6B... 2/1/2018a> gvi Florida Building Code Online Page 3 of 4 Design Pressure: +55/-55 3),od Other: R-PG55, Missile Level D, Wind Zone 3. Glass to be FL17499 R3 C CAC MI Windows - 185 SH (Flance) Imoact 2).odbeddedinPecora896sealant. FL17499 R3 C CAC MI Windows - 185 SH (Flance) Impac 5).pd Quality Assurance Contract Expiration Date 10/10/2018 Installation Instructions FL17499 R3 II 08-02544B-I.pdf Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 51332OB-1.[)d Created by Independent Third Party: Yes 17499.6 185 SH 52x84 Fin/Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC APC(13362)El725.01-109-47-RO 185 SH(FLG waiver)5-81G 1-8A 52 1-SX84 R60(100918).pdfApprovedforuseoutsideHVHZ: Yes FL17499 R3 C CAC MI Windows - 185 SH (Fin) (10).QdImpactResistant: No FL17499 R3 C CAC MI Windows - 185 SH (Fin) (9).PdDesignPressure: +60/-60 FL1 7499 R3 C CAC MI Windows - ISS SH (Flange) (9). pdfOther: R-PG60 Quality Assurance Contract Expiration Date 10/09/2018 Installation Instructions FL17499 R3 II 08-02546B-2.r)d Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513322-B-2.c)df Created by Independent Third Party: Yes 17499.7 185 Triple SH 111x72 Fin Frame IG/SG Single Hung 110x72 Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC MI Windows - 185 SH Triple (FJn) 3), pdApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL17499 R3 C CAC MI Windows - 185 SH Triple (Fin) 4)-odDesignPressure: +50/-50 Other: R-PG50* FL17499 R3 C CAC MI Windows - 185 SE_Lr iple (Flangel 3). Qd FL17499 R3 C CAC MI Windows - 185 SH Triple (Flanae) 4). pd Quality Assurance Contract Expiration Date 10/20/2018 Installation Instructions FL17499 R3 II 08-02548B.pdf Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513324B-6.pd Created by Independent Third Party: Yes 17499.8 185 Twin SH 106x72 Fin Frame IG/SG Single Hung 105x72 Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC MI Windows - 185 SH Twin (Fin) 3).odApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL17499 R3 C CAC MI Windows - 185 SH Twin (Fin) 4). QdDesignPressure: +45/-45 Other: R-PG45 FL17499 R3 C CAC MI Windows - 185 SH Twln Flange) 3).Dd FL17499 R3 C CAC MI Windows - 185 SH Twin (Flange) 4).Dd Quality Assurance Contract Expiration Date 10/20/2018 Installation Instructions FL17499 R3 H 08-02547B-7.r)d Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513323B-7.1)df Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone, 850-487-182 The State of Florida is an AA/EE0 employer. Copyright 2007-2013 State of Florida. :: Pri acy Statemen ;: Accessibility Statemen :: Refund Statement htt s://w-ww.floridabuildinc,.orcr/pr/pr app dtl.aspx?param=wGEVXQwtDqtCUGevjQiz6B... 2/1/2018PI'D 1.) — Flonida Building Code Online Page 4 of 4ZZ, Under Florida Ia., email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send el ectronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to action 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Appro al Accepts: M ;_R51 LE:= 13 I I... I ... . .... ........ Credit Card safe https://www.floridabuilding.ora/pr/pr p dt.aspx?param=wGEVXQWtDqtCUGO' Qiz6B... 2/l/2018ap _ I :z1vi NOTES: I . THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE IX BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16-- OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 11 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. REVISIONS DESCRIPTION DATE A PROVED REVISED ANCHOR SPACING & CHARTS 07/11/16 R. L. REVISED GLASS 10/02/17 R.L. 15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16-- TAPGONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS, 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT. 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,OODPSI MINIMUM. D. METAL STRUCTURE: STEEL I8GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063—T5 FU=30KSl .048" THICK MINIMUM I TABLE OF CONTENTS , I SHEET NO. 1 DESCRIPTION 1 1 NOTES 2 3 ELEVATIONS 4 10 INSTALLATION DETAILS 11 1 COMPONENTS SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC Jllllfljll 650 WEST MARKET STREET I b 11 L o I'// 4f GRATZ, PA 17030-0370 E 14 (P9 0 5 fSERIES185ALUMINUMSINGLEHUNGWINDOW 52" X 72" NON -IMPACT al-t . NOTES 0. E OF tQzz DRAWN: T w REV N. G. 08-02549 B ONA. 1111111i\0SCALDATEESHEETNTS12/29/14 OF 11II I Luis R. Lomas P.E. FL No.: 62514 L. ROBERTO LOMAS P.E. 1432WOODFOR RD LEWISVILLE, NC 27023434-588-06091) r1lomas(Pirlotnaspe—m 52" MAX FRAME WIDTH 52" MAX FRAME WIDTH 2" MAX — 16" MAX D.C. 2" MAX 2 11 MAX 16" MAX D.C. 2" MAX 1 16" MAX D.C. 72" MAX FRAME HEIGHT 2" 16" MAX O C. 72" T_ MAX FR ME HEI HT 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW DESIGNER EXTERIOR VIEW FLANGE& FINLESS INSTALLATION FLANGE& FINLESS INSTALLATION SEE CHART#I FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART#1 FOR SMALLER UNITS REQUIRED ANCHORS DESIGN PRESSURE RATING IMPACTRATING 60.OPSF NONE NOTES: 1. MAXIMUM SASH SIZE: 51" X 36". 2. MAXIMUM SASH D.L.O.: 47 5/8" X 32 1/2". 3. MAXIMUM FIXED D.L.O.; 49 3/8" X 32 1/2", HARDWARE SCHEDULE METAL SWEEP LOCK AT 8" FROM EACH END INTERIOR MEETING RAIL BLOCK AND TACKLE BALANCE AT JAMBS RE nSIONS REV DE CRIPTIO14 DATE APPROVED A REVISED ANCHOR SPACING & CHARTS .7/ ' 1/16 B REVISED CLASS 10/ ;2/17 CHART#I Number of anchor locations required Frame Frame Width (in) Height 18.00 24.00 3 .00 36.00 42.00 1 48.00 52.00 in) Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb Head I Jamb Head I Jamb 24.00 2 3 3 3 3 3 3 3 4 3 4 1 3 4 3 30.00 2 3 3 3 3 3 3 3 4 3 4 3 4 3 36.00 2 3 3 3 3 3 3 3 4 3 4 3 4 3 42.00 2 4 3 4 3 4 3 4 4 4 4 4 4 4 48.00 ET o 2 4 3 4 3 4 3 4 4 4- 4 4 4 4 2 5 3 5 3 5 3 5 4 5 4 5 4 5 2 5 3 5 3 5 3 5 4 5 4 5 4 5 66.00 3 5 3 1 5 3 I J_4 1:4 4 5 4 5 72.00 1 3 6 3 1 6 3 1 4 1 6 4 6 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON -IMPACT FLANGE & FINLESS ELEVATIONS DRAWN: DWG NO. N. G. 08-0: SCALE NTS J'ATE 12/29/14 SHEET 2 OF 11 L ROBERTO LOMAS P. E. 1432 WOODFORD RD LEWiSVILLE, NC 27023 434-688-0609 r1lomas9fdomaspe- SIGNED: 1211412017 R L o r, N 8 .:,p 0 5 P 6A 0 0 OR Luis R. Lomas P.E. FL No.: 62514 52" MAX FRAME WIDTH 52" MAX FRAME WIDTH 2" MAX 10" MAX O.C. 2" MAX 2" MAX 10" MAX O.C. 2" 10" loll AXM O.C. MAX O.C. T_' 72" 72" MAX MAX FRAME HEIGHT FRAME HEIGHT RE\flSIONS REV DESCRIP71ON DATE PPROVED 2" MAX A REVISED ANCHOR SPACING & CHARTS 07/11/16 R. L. B REVISED GLASS 10/02/17 1 R.L. yA 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW EXTERIOR VIEW FINiNSTALLATION FIN INSTALLATION SEE CHART#2 FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART#2 FOR SMALLER UNITS REQUIRED ANCHORS DESIGN PRESSURE RATING IMPACTRATING 60.OPSF NONE NOTES: 1. MAXIMUM SASH SIZE: 51" X 35". 2. MAXIMUM SASH D.L.O. : 47 5/8" X 32 1/2". 3. MAXIMUM FIXED D.L.O.: 49 3/8" X 32 1/2". HARDWARE SCHEDULE i ETAL SWEEP LOCK AT 8" FROM EACH END INTERIOR MEETING RAIL BLOCK AND TACKLE BALANCE AT JAM BS CHART#2 Number of anchor locations required Frame Frame Width (in) Height f8'00 24.00 30.00 36.00 1 42.00 48.00 52.00 I n) H&S Jamb H&S Jamb H&SS Jamb H&S IJamb IH&S Jamb H&S Jamb H&S Jamb 24.00 3 3 3 3 4 3 5 5 3 6 3 6 3 30.00 3 4 3 4 4 4 5 4 5 4 6 4 6_ 4 36.00 3 5 3 5 4R4 6 5 5 5 5 6 5 6 5 42.00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 48.00 3 6_ 3 6 4 6 5 6 5 6 6 6 1 6 6 54.00 3 6 3 6 6 5 6 5 6 6 6 1 6 6 60.00 3 7 11 4 7 5 7 5 7 1 6 7 66.00 3 8 3 8 4 8 5 8 5 li- 8 6 8 8 3 8 4 1 8 1 5 1-1 6 8 6 8 SIGNED: 1211412017 M1 WINDOWS AND DOORS, LLC 650 WEST MARKET STREET 0 4f GRATZ, PA 17030-0370 f*: 5SERIES185ALUMINUMSINGLEHUNGWINDOW 52" X 72" NON —IMPACT 04 F'OFFINELEVATIONSTAT 0 NDRAWN: 11WG 110, R N.G. 08-02549 B Luis R. Lomas P.E. FL No.: 62514 SCALE NTS DATE 12/29/14 15111ET 3 OF 11 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688 0609 r1IotNas@)IrfomaSpe- REVISIONS 1/2" MIN REV DESCRIPTION ATE APPROVED WOOD FRAMING EDGE DISTANCE A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L. OR 2X BUCK B REVISED GLASS 10/02/17 R L. BY OTHERS 1 1/4" MIN. EMBEDMENT BACKER ROD APPROVED 1/ MAX SEALANT SHllM SPACE I 10 WOOD SCREW INTERIOR EXTERIORk BACKER ROD APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS VERTICAL CROSS SECTION SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4" MAX. SHIM SPACE WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 1 1/4" MIN. EMBEDMENT 1 1/2" MIN EDGE DISTANCE 10 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS 1/4" MAX. SHIM SPACE INTERIOR BACKER ROD APPROVED EXTERIOR SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR2X BUCK INSTALLATION SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET R L 041 yGRATZ, PA 17030-0370 P 5SERIES185ALUMINUMSINGLEHUNGWINDOW 52" X 72" NON —IMPACT OFFLANGEINSTALLATIONDETAILSTAT 0 DRAWN: N. G. 3 014AL Illin\0T4OF11ILuisR. Lomas P.E. L. ROBERTO LOMAS RE 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 tiloinas@ltlomaspe.com FL No.: 62514 m"' STRUCTU BY OTHE APPROVED SEALANT 2" MIN EDGE DISTANCEr--r i 1/4" MAX. SHIM SPACE 10 SIAS OR SELF DRILLING SCREW INTERIOR EXTER10114 BACKER ROD APPROVED SEALANT META STRUCTUR BY OTHER SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4" MAX. SHIM SPACE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 REVISIONS REV DESCRIPTION DATE AP ROVED A REVISED ANCHOR SPACING & CHARTS 07/11/16 R. L. 8 REVISED CLASS 10/02/17 1 R.L. 1/4" MAX. SHIM SPACE R10SMSOR0 IINTERIOROF, NGSELFDRILLINGL' EW SSCREWS 1 2 NTER 11 MIN. EDGE DISTANCE T__ XT OtEXTERIOR METAL STRUCTURE BACKER ROD BY OTHERS APPROVED SEAL -ANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 1211412017 MI WINDOWS AND 'DOORS, LLC 0\MI)I////,// 650 WEST MARKET STREET c Lo ff GRATZ, PA 17030-0370 1-0 P 5 0;1? 5 fSERIES185ALUMINUMSINGLEHUNGWINDOW 52" X 72" NON —IMPACT a vli - t _ FFLANGEINSTALLATIONDETAILSA . CMO e Luis R. Lomas P.E. DRAWN: N.G. DWG NO. 08-02549 REV SCALE NTS DATE 12/29/14 SHEET 5 OF 11 I. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rilomasoirlomaspe.com FL No.: 62514 2 1/2" MIN. CONCRETE/MASONRY EDGE . DISTANCE BY OTHERS 4 4 . 14 MIN. OPTIONAL IX BUCK 1 1/4 4 SEE NOTES 3 — 7 EMBEDMENT SHEET I 1/4" MAX. BACKER)R 0 D SHIM SPACE APPR( 'ED SEALANT 3/16" TAPCON INTERIOR EX TER/OR7y REVISIONS REV DESCRIPTION DATE APPROVED A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L. 8 REVISED CLASS 10/02/17 R.L. 1 1/4 " MIN. EMBEDMENT 1/4" MAX. CONCRETE/MASONRY SHIM SPACEBYOTHERS 3/16" TAPCON INTERIOR 2 T_ 1/2" MIN. EDGE DISTANCE EXTERIOR BACKER ROD APPROVED OPTIONAL 1X BUCK SEALANT SEE NOTES 3 — 7 SHEET I JAMB INSTALLATION DETAIL CONCRETEIMASONRYINSTALLATION SILL TO BE SET NOTES: BACKER ROD IN A BED OF 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. APPROVED APPROVED STRUCTURAL 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE SEALANT SEALANT DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 1211412017 OPTIONAL 1X BUCK SEE NOTE 3 — 7 1/4" MAX. F SHIM SPACE MI WINDOWS AND DOORS, LLC FL L 0 xSHEET1 T 650 WEST MARKET STREET GRATZ, PA 17030-0370 41yI- G Als, ..'p CONCRETE/MASONRY BY OTHERS 4' 4 i SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS TV DRAWN: 0AA, N.G. DWG NO. 08-02549 REV B f' 0 RlDt ONALTCALE ____T_ NTS 12/29/14 SHEET 6 OF 11 I 11/ 11 VERTICAL CROSS SECTION CONCRETEImASONRY INSTALLATION LROBE TOLOMASP.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 Luis R. Lomas P.E. 434-688-0609 r1lo—S01116—spex— FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD APPROVED SEALANT BACKER ROD APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 1/2" MIN EDGE DISTANCE 1/4" MAX. HIM SPACE 10 WOOD SCREW R SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4" MAX. SHIM SPACE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINTSEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WIT14 ASTM E2112 REVISIONS REV DESCRIPTION DATE APPROVED A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L. 0 REVISED GLASS 10/02/17 R.L. I 1 1/4" MIN. 1/4" MAk EMBEDMENT SHIM SPACE i 1/2" MIN INTERIOR EDGE DISTANCE Pal 10 WOOD SCREW WOOD FRAMING XTERIORf OR 2X BUCK BY OTHERS BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS DRAWN: DWG NO. N.G. 1 08"02549 SCALE NTS I DATE 12/29/14 1 SHEET 7 OF 11 L. ROBERTO LOMAS P. E. 1432 WOODFORD RD LEWISVILLE, NG 27023 434-688-0609 r1fornasoirlomaspe.com SIGNED: 1211412017 0 E N T AT' 5 OF R ;P ORM.- 0NAIL Luis R. Lomas P.E. FL No.: 62514 2 1/2" MIN. ED G,E'D IST A N CE. CONCRETE/MASONRY BY OTHERS 4 4' 1 1/4" MIN. OPTIONAL 1X BUCK 4 EMBEDMENT SEE NOTES 3 — 7 SHEET 1 1/4" MAX. BACKER ROD SHIM SPACE APPROVED SEALANT 3/16" TAPCON LINTEMORNTERt EXTERIORk 1 1/4" MIN. EMBEDMENT CONCRETE/MASONRY BY OTHERS 3/16" TAPCON 2 1/2" MIN. EDGE DISTANCE REVISIONS REV DESCRIPTION DATE APPROVED A REVISED ANCHOR SPACINC & CHARTS 07/11/16 R.L. B REVISED CLASS 10/02/17 R.L. OPTIONAL IX BUCK SEE NOTES 3 — 7 SHEET 1 4" MAX. ISHIM SPACE INTERIOR BACKER ROD EXTERIOR APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETEIMASONRYINSTALLATION SILL TO BE SET BACKER ROD IN A BED OF APPROVED NOTES: APPROVED STRUCTURAL 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, SEAL -ANT SEALANT NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TOBE OPTIONAL IX BUCK 1/4" MAX. DESIGNED IN ACCORDANCE WITH ASTM E2112 SEE NOTE 3 — 7 F SHIM SPACE SIGNED: 1211412017 SHEET I T MI WINDOWS AND DOORS, LLC CONCRETE/MASONRY 650-WEST MARKET STREET GRATZ. PA 17030-0370 L041 BY OTHERS 14 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 0 5 4. 52" X 72" NON —IMPACT4 4 FINLESS INSTALLATION DETAILS TA OF cc zzlijZ DRAWN: Dwc NO. OR VERTICAL CROSS SECTION G. 08-02549 r13 4 CONCRETEIMASONR Y INS TALLA TION ALE NTS I DATE 12/29/14 1 SHEET 9 OF 111' 1 \k\\ L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE. IVC 27023 Luis R. Lomas P. E. 434-688-0609 ritomasc@lrtomaspe.com FIL No.: 62514 APPROVED SEALANT BEHIND FIN 7/16" MIN EDGE DISTANCE INTERIOR EXTERIOR3 7/16" MIN EDGE DISTANCE APPROVED SEALANF BEHIND FIN 1 1/4" MIN. EMBEDMENT 8 WOOD SCREW EmOrUIVILI'll VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION WOOD FRAMING BY OTHERS 1/4" MAX. SHIM SPACE REVISIONS REV DESCRIPTION ANCHOR SPACING & CHARTS 8 1 REVISED CLASS WOOD FRAMING _\ 1/4" MAX BY OTHERS —1 [_ SHIM SPACE 6 WOOD SCREW INTERIOR 1 1 /4 MI N 1118EDM ENT T_ APPROVED SEALANT BEHIND FIN 7/16" MIN EXTERIOR EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION DATE APPROVED 07/11/16 R.L. 10/02/17 R.L. NOTES: 1/4" MAX 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, SHIM SPACE NOT SHOWN FOR CLARITY 2. PERIMETER AND JOWT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITHASTM E2112 SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC WOOD 650 WEST MARKET STREET I \\ r P, L 0 FRAMING GRATZ, PA 17030-0370 BY OTHERS SERIES 185 ALUMINUM SINGLE HUNG WINDOW 0 52" X 72" NON —IMPACT FIN INSTALLATION DETAILS T T"; OF DRAWN: NO- JDWG 'EV_ N.G. 08-02549 B 10NAI_ SCALE NTS DATE 12/29/14 1 sHEET 10 OF 11 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 Luis R. Lomas P.E. 434-688-0609 r1loniascavlo—spe.com FL No.: 62514 METAL STRUCTURE BY OTHERS APPROVED SEALANT EXTERIOR BACKER ROE APPROVEE SEALANI METAL STRUCTURE BY OTHEI— 1/2" MIN EDGE DISTANCE 1/4" MAX. SHIM SPACE IQ no SELF DRILLING SCREW INTERIOR VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINTSEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITHASTM E2112 SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4" MAX. SHIM SPACE REVISIONS T AlREVIDESCRIPTIONDATE ROVED A REVISED ANCHOR SPACING & CHARTS 07/11/16 R. L. B REVISED GLASS 10/02/17 R.L. 1/4" MAX. SHIM SPACE 10 SMS OR INTERIOR SELF DRI LLI NG SCREWS 1/2" MIN. EDGE DISTANCE I — EXTERIOR METAL BACKER ROD STRUCTURE APPROVED BY OTHERS SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 9- LOc E N 0 5SERIES185ALUMINUMSINGLEHUNGWINDOW 52" X 72" NON-IMPACT FINLESS INSTALLATION DETAILS A . T Af"OF 0 ON A 1- 1//IjIIII0\ DRAWN: N. G. DWG NO. 08-02549 REV B7 TCALE NTS IIATE 12/29/14 1 SHEET 13 OF 11 L. ROBERTO LOMAS P.E. 1432 WOODrORD RD LEWISVILLE. NC 27023 434-688-0609 'jj_ascWll—aspe.— Luis R. Lomas P.E. FL No.: 62514 2 3/16" 1 7/8 T_ 2 3/16" 13/16" 2 3/16"" 1 W== 1 5 7/ 16' 4. T=== j f I L=H FLANGE FRAME HEAD FLANGE FRAME JAMB FINLE -AD CM-18501 CM- 18503 CM-18553 A L UMINUM 6063- T5,050" THICK AL UMINUM 6063- T5.050' THICK ALUMINUM 6063- T5.050" THICK 2 5/16" 2 5/16" 2 5/16" F33/8" 2 13/1 E 3 3/4" L 3E FRAME SILL FINLESS FRAME SILL CM- 18502 CM-18554 ALUMINUM 6063- T5.055' THICK ALUMINUM 6063-T5.055" THICK CM-18509 L ALUMINUM 6063-T5.055" THICK 1 7/16" 5/8.. - 1 1/8" T-Iff- T- 2 5/16" 2" L L ILE SASH BOTTOM RAIL MEETING RAIL CM- 18505 CM_ 18555 . CM- 18504 ALUMINUM 6063-T5.062" THICK ALUMINUM 6063-T5.050" THICK ALUMINUM 6063-T5.055" THICK 11 3/8 15/16" G BEAD SASH STILE CM- 18535 CM- 18507 RIGID PVC.050" THICK ALUMINUM 6063-T5.050"THiCK 2 3/16" FINLESS FRAME JAMB CM- 18513 AL UMINUM 6063-T5.050" TRICK 3/ T— — 2 — 16" — 2 /16" 5 E F71AI TrPA AAP 14PA n ALUMINUM 6063-T5.050"THICK 2 3/ 2 3/16" FIN FRAME JAMB CM-18510 ALUMINUM 6063-T5.050" THICK REV15IONS DESCRIPTION -TE I 111PI1.111. REVISED ANCHOR SPACING & CHARTL R.L. REVISED GLASS 1 10/02/17 1 R.L. 5/8" — 1/8" ANN. — 1/8" ANN. 1/8" ANN. 090 PVB BY KURARAY METAL REINFORCED BUTYL SPACER EX1*1TER10H INTERIOR 1/2 BITE SILICONE SEAL -ANTFC- SETTING BLOCK GLAZING DETAIL MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON -IMPACT COMPONENTS IN: TDWG NO — ------------ 7 N.G. 1 08-02549 NTS I IIAIE 12/29/14 SHEET 1 1 OF 11 L. ROBERTO LOMAS RE 1432 WOODFORD RD LEWISVILLE, NC 27023 434_688-0609 rlfomas@lrlomaspe-M SIGNED: 1211412017 0%IIVIIII////' 0 0 5 A TAViOFSTAT 0 7EI B ONAL 100 Luis R. Lomas P.E. FL No.: 62514 Florida Buildinor Code Online4D Page 1 of 3 ITZ: n I =-1 8CIS Home Log In i User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search d,bapr L Product Approval USER: Public User Product Approval Menu > Product or Application Sgarch > Application Lis > Application Detail FL# FL15349-R9 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich, PE R Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard AAMA 506 AAMA/WDMA/CSA 101/I.S. 2/A440 Equivalence of Product Standards Certified By Product Approval Method Method I Option A Date Submitted 12/31/2017 Date Validated 12/31/2017 Date Pending FBC Approval Date Approved 01/04/2018 Year 2011 2008 https://www.flon*dabuildino,.org r/pr p dtl.aspx?param=wGEVXQwtDqtH8572qvdWI... 1/31/2018 Z) :,/p _ap _ Florida Building Code Online Page 2 of 3) Summary of Prod FL # Model, Number or Name Description 115349.1 1185 PW 73 . 72 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R9 C CAC APC 12786.odf Approved for use outside HVHZ: Yes FL15349 R9 C CAC APC 12787.pd Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +60/-60 04/03/2018 Other: CW-PG60 Installation Instructions FL15349 R9 11 08-02357B.od Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports FLI.S349 R9 AE 513124B.od Created by Independent Third Party: Yes 15349.2 1785 PW 159 x 54 Triple CHS Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R9 C CAC APC 15350.pd Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 01/24/2021 Design Pressure: +55/-55 Installation Instructions Other: R-PG55 FL15349 R9 II 08-02949.od Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports EL15349 R9 AE 513783.pdf Created by Independent Third Party: Yes I 118S PW Impact 72 x 72 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R9 C CAC APC 15454.i)df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/25/2021 Design Pressure: +55/-55 Installation Instructions Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FL15349 R9 II 08-02948.pd consisted of 5/32" tempered exterior - spacer - 5/32" Verified By: Luis R. Lomas, PE 62514 annealed / 0.100 Solutia Saflex HP / 5/32" annealed. Glass Created by Independent Third Party: Yes was bedded in Pecora 896 silicone with 5/8" glass bite. Evaluation Reports FL15349 R9 AE 513782,Qd Created by Independent Third Party: Yes 15349.4 185 PW Impact 159 x 54 Triple CHS Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R9 C CAC APC8272.od Approved for use outside HVHZ: Yes FL15349 R9 C CAC APC 8273.pdf Impact Resistant: Yes Quality Assurance Contract Expiration Date Design Pressure: +55/-55 01/24/2021 Other: FW-R55, Missile Level D, Wind Zone 3. Glass Installation Instructions consisted of 1/8" annealed exterior - spacer - 3/32" FL15349 R9 II 08-01614B.pd annealed / 0.090 Solutia PVB / 3/32" annealed. Glass was Verified By: Luis Roberto Lomas 62514 bedded in Pecora 896 silicone with S/8" glass bite. Created by Independent Third Party: Yes Evaluation Reports FL15349 R9 AE 512278B.I)d Created by Independent Third Party: Yes 15349.5 1185 PW Impact 96 x 60 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLIS349 R9 C CAC APC 7962.od Approved for use -outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/05/2020 Design Pressure: +55/-55 Installation Instructions Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FL15349 R9 TI 08-01613B.od consisted of 5/32" annealed exterior - spacer - 5/32" Verified By: Luis Roberto Lomas 62514 annealed / 0.100 Solutia Saflex HP / 5/32" annealed. Glass Created by Independent Third Party: Yes was bedded in Pecora 896 silicone with S/8" glass bite. Evaluation Reports FL15349 R9 AE 512277B.od Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone 850-487-182 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen https://www.flon*dabuilding.orc.,Iprlpr_app_dtl.aspx?para,m=wGEVXQwtDqtH8572qvdWl... 1/31/2018 Florida Buildincly Code Online I., Paae 3 of 3 Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.139S. -Pursuantto Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M 0 *_a E M cra&"" Card, Safe https://www.floridabuildino,.oro, r/pr app dtl.aspx?pararn=wGEVXQwtDqtHS572qvdWI... 1/3 :) 1/201821/p — NOTES: 1 . THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE IX BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. B. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16- OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED ALUMINUM 6063—T5. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #6 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. REVISIONS I DESCRIPTION — I AP ROVED REVISED INSTALLATION DETAILS 06/01/15 R.L. REVISED NAME AND ADDRESS 10/27/16 R.L. 15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME INTO MASON RY/CON CRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. I B. ALL FASTENERS TO BE CORROSION RESISTANT. 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=O * 42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,OODPSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063—T5 FU=3OKSI .048" THICK MINIMUM 20. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN IN SHEET 2. TABLE OF CONTENTS SHEET NO. DESCRIPTION 1 NOTES 2 — 3 ELEVATIONS, CHARTS AND GLAZING DETAILS 4 — 12 INSTALLATION DETAILS SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. S Ft. Lo 4f GRATZ, PA 17030 4" SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT NOTES WCO 0. ZORIDDRAWN: llWG NO. R L. 08-02357 B ONAI_ Luis R. Lomas P.E. FL No.: 62514 ICALE NTS DATE 09/03/14 SHEET i OF 12 IL. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISYILLE, NC 27023 434-688-0609 dl CMW.-p.- 72 1/2" MAX FRAME WIDTH 6" MAX 18-1 MAX D.C. 6" MAX 6 _rAK_ 18" 0/ MAX O.C. 71 1/2" MAX FRAME HEIGHT j REFER TO CHARTS SERIES I, FOR NUMBER OF 185 ALUMINUM FIXED WINDOW EXTERIOR VIEW ANCHORS REQUIRED 72 1/2" MAX FRAME WIDTH 6" MAX l a" MAX O.C. 6" MAX 6' 71 1/2" 18 MAX MAX O.C. FRAME HEIGHT T-_j REFER TO CHARTS SERIES 185 ALUMINUM FIXED DESIGNER WINDOW 1 & #2 EXTERIOR VIEW FOR NUMBER OF ANCHORS REQUIRED DESIGN PRESSURE RATING IMPACTRATING 60.OPSF NONE NOTES: 1. MAXIMUMD.L.O.: 69314'X68314" REVISIONS DESCRIPTION DATE APPROVED REVISED INSTALLATION DETAILS 06/01/15__Rl.. ISED NAME AND ADDRESS 10/27/ 1 6 1 R.L. CHART#I Number of anchors required (tviihout rigid fillers) Frame Frame width (in) Height 24.00 T-30.00 36.00 42.00 48.00 1 54.00 60.00 1 66.00 72.50 I-) HAS P.mbl HAS P."'b HAS Jamb HAS Ja,.b HAS P.ndbj HAS Paint, HAS Jamb HAS Ja b HAS Ja b 24.00 2 1 2 1 2 2 3 2 3 2 3 1 2 1 4 1 2 4 2 4 2 5 2 30.00 2 2 1 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 36.00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 5 3 5 3 42.00 2 3 2_ 3 3 3 3 3 3 3 4 3 5 3 5 3 6 3 48.00 2 3 2 3 3 3 3 3 3 3 4 3 5 3 6 3 6 3 5400 2 4 2 4 1 3 4 3 4 3 4 4 4 5 4 6 4 7 4 60.00 2 4 2 4 1 3 4 3 5 3 5 4 5 S 5 6 5 5 600, 7r l 1 71.60 2 5 2 5 1 3 5 3 1 6 1 3 6 17 6 1 7 7 1 7 CHART #2 Number of anchors required (with rigid fillers) Frame Frame width (in) lkight 24.60 30 0 1 36.00 42 0 1 48.00 1 54.00 0 00 1 72.10 lin) HT_P__ S amb H AS Jamirl HAS Paint, HAS P4111151 HAS Pambl HAS Jamb HiT HA'S' J.,nbj HAS Paint, 24.00 2 1 2 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 30.00 2 2- 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 36.00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 4 3 5 3 42.00 2 3 2 3 3 3 3 3 3 4 3 4 3 4d4 3 5 3 1 48.00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 4 3 54.00 2 4 2 4 3 4 3 4 3 4 4 4 4 4 4 60.00 2 4 2 4 3 4 3 4 3 4 4 4 4 4 4 4 A5366.00 2 4 2 4 3 4 3 4 3 4 4 4 4 4 4 150 3 5 I 1 3 1 4 5 4 1 5 S SEESHEETS 4-7FOR INSTALLATION DETAILS MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ . PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON -IMPACT FLANGE & FINLESS ELEVATION & CHARTS DRAWN: DING NO. J.L. 08-02357 SCALE NTS JDATE 09/03/14 1 SHEET 2 OF 12 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 r1lomasCaWfomaspe.com SIGNED: 1111512016 0 G tp 0TAT 0 R _EV 0 N A L I) 11110\\ Luis R. Lomas P.E. FL No.: 62514 71 F Hl 6" MAX — 72 1/2" MAX FRAME WIDTH 18" MAX D.C. 6" _rAK_ 0/ MAX D.C. T_ 1/2- IAX AME IGHT 6" MAX REFER TO CHART #3 —,-- SERIES 185 ALUMINUM FIXED WINDOW FOR NUMBER OF EXTERIOR VIEW ANCHORS REQUIRED 72 1/2- MAX FRAME WIDTH 6" MAX 18 .' MAX D.C. 6" MAX 0/// 18" MAX O.C. 71 1/2" MAX FRAME 00 HEIGHT I 1 00 REFER TO CHART #3 -- FOR NUMBER OF SERIES 185 ALUMINUM FIXED DESIGNER WINDOW ANCHORS REQUIRED EXTERIOR VIEW DESIGN PRESSURE RATING MPACTRATING 60.OPSF NONE NOTES: 1. MAXIMUMD.L.O.: 69314"X66314" REVISIONS REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/01/15 R.L. B REVISED NAME AND ADDRESS 10/27/1 A I R I CHART#3 Number of anchors required (fin installation) Frame Frame width tin) Height 24.00 30.00 36 00 42.00 48 0 54.00 1 6000 1 66.00 1 72.50 in) H&S Paint, H&S Jamb H&S, Pambl H&S P-4, H&S P-dbj H&S P.nrb H&SP..blH&Sp..b H&S J.,nb 24.00 3 3 3 3 3 3 4 3 4 3 4 3 5 3 5 1 3 6 3 3 3 3 3 3 3 4 3 4 3 4 5 3 5 3 6 3 36.00 3 3 3- 3 3 3 4 3 4 3 4 3 5 3 5 3 6 3 42.00 3 4 3 4 3 4 4 4 4 4 4 4 5 4 5 4 6 4 48.00 314 3 36 4 3 4 4 4 4 4 4 4 5 4 5 4 6- 4E30. 00 54.00 3 4 3 4 3 4 4 4 4 4 4 4 5 4 5 4 6 4 6 Dtt0.00 3 5 3 5 3 5 4- 5 4 5 4 5 5 5 5 5 5 66.00 3 5 3 5 3 5 4 5 4 5 4 5 6 5 71.50 3 6 6 I SEE SHEET 8 FOR INSTALLATION DETAILS MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 0030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FIN ELEVATION & CHART DRAWN: DWG NO. J. L. 08-02357 DATE 09/03/14 SHEET 3 OF 12 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 r1lomasCaWrIamasDe.mm SIGNED: 1111512016 IR Lo 1// rEN&I. 0 TTA='_:: 0 ORID 10NALdlz /4/1111111110\ V' Luis R. Lomas P.E. FL No.: 62514 REVISIONS 1/2" MIN REV D SCRIPTION TE APPROVED EDGE DISTANCE 3/4" MIN A REVISED INSTALLATION DETAILS 06/01/15 R.L. WOOD FRAMING 1/4" MIN. METAL EDGE DISTANCE B REVISED NAME AND ADDRESS 10/27/11, R.L._ OR : EMBEDMENT BY OTHERS BY OTHERS 1/4" MAX. 2X BUCK 1 STRUCTURE F SHIM SPACE BAC KER ROD SHIM SPACE BACKER ROD APPROVED APPROVED SEALANT SEALANT 10 WOOD SCREW EXTERIOR EXTERIOR INTERIOR 10 WOOD SCREW RIGID FILLER BACKER ROD BACKER ROD APPROVED 1/4" MAX. APPROVED SEALANT SHIM SPACE SEALANT WOOD FRAMING 1 1/4" MIN. METAL OR 2X BUCK BY OTHERS EMBEDMENT STRUCTURP l BY OTHERS 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4" MIN. /4" MAX, EMBEDMENT S HIM SPACE 1/2 MIN. E /I INTERIOR 10 WOOD SCREW WOOD FRAMING EXTERIOR OR 2X BUCK L—A, '_. , , BY OTHERS BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION I- 3/4" MIN. EDGE DISTANCE 10 SMS OR SELF DRILLING SCREW INTERIOR 10 SMS OR SELF DRILLIN13 SCREW RIGID FILLER 1/4" MAX. SHIM SPACE 3/4" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION 4" MAX. S HIM SPACE INTERIOR 10 SMS OR SELF DRILLING SC REINS METAL EXTERIORYJ4 . _' _i STRUCTURE BACKER ROD BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC w\IIIIII/j// 650 W. MARKET ST. GRATZ, PA 17030 F, L 0 41 1EN \r, Nq (P SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FINLESS INSTALLATION DETAiLS WITHOUT FILLERS P41 TAT: OF 0 e,, ;A 0 R V0" t DRAWN: DW(3 NO. REV J. L. 08-02357 1 z/ d" . . . - SCALE NTS 1—'09/03/14 S.EET1 4 0 F 12 Luis R. Lomas P.E. L ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 riloinas@lrltmiaspe.com FL No.: 62514 REVISIONS REV D SCRIPTION DATE 2 1/2" MIN. APPROVED A REVISED INSTALLATION DETAILS 06/01/15 R.L. EDGE DISTANCE B REVISED NAME AND ADDRESS 10/27/16 R. L. CONCRETE/MASONRY - BY OTHERS 14 d 1 1/4" MIN. 1 1/4" MIN. EMBEDMENT MOPTIONALIXBUCK SEE NOTES 3 — 7 EMBEDMENT SHEET I L—L CONCRETE/MASONRY BACKER ROD 1/; MAX BY OTHERS 1/4" MAX, APPROVED SHIM SPACE SHIM SPACE SEALANT OPTIONAL 1X BUCK SEE NOTES 3 — 7 SHEET I 3/16" TAPCON EXTERIOR INTERIOR 3/16" TAPCON INTERIOR 3/16" TAPCON BACKER ROD APPROVED SEALANT 1/4" MAX. 2 1/2" OPTIONAL IX BUCK SEE NOTE 3 — 7 SHIM SPACE MIN. Willi SHEET I EDGE DISTANCE EXTERIOR CONCRETE/MASONRY BACKER ROD BY OTHERS 4 14 4" MIN. APPROVED EMBEDMENT SEALANT 4. JAMB INSTALLATION DETAIL CONCRETEIMASONRY INSTALLATION 271/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETEIMASONRYINSTALLATION SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. S R - L 0 GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOWNOTES: 404511. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, 73" X 72" NON —IMPACT NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE FINLESS INSTALLATION DETAILS WITHUT FILLERS A TATVOF9 DESIGNED IN ACCORDANCE WITH ASTM E2112 0 DRAWN: DWG 110, REV J. L. 08-02357 j/0NAL09/03/14 I S"EEl 5 OF 12 I 01111110\ r 11111'11' 1'-' I. ROBERTO LOMAS P.E. 432 WOODFORD RD LEWISVILLE, NG 27023 Luis R. Lomos P.E. 434-5880609 rtiomas@irloniaspe.com FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD APPROVED SEALANT EXTERIOR BACKER ROD APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 1/2" MIN. EDGE DISTANCE 1 1/4" MIN F EMBEDMENT 1/4" MAX SHIM SPACE RIGID FILLER 10 WOOD SCREW 10 WOOD SCREW RIGID FILLER 1/4" MAX. SHIM SPACE MIN EMBEDMENT 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4" MIN. 1/4" MAX. EMBEDMENT SHIM SPACE F_ - RIGID FILLER 1/2" IN GE DIS El I ' TAt CE INTERIOR 10 WOOD WOOD FI SCREW EXTERIOR OR 2X BUCK BY OTHERS BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE BY OTHERS BACKER ROD APPROVED SEALANT EXTERIOR BACKER ROD APPROVED SEALANT META STRUCTUR BY OTHER 3/4" MIN EDGE DISTANCE 1/4" MAX F SHIM SPACE RIGID FILLER 10 SMS OR SELF DRILLING SCREW INTERIOR SMS OR DRILLING W FILLER 1/4" MAX. SHIM SPACE 3/4" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION 1/4" MAX, SHIM SPACE RIGID FILLER 3/4" MIN. EDGE DISTANCE INTERIOR 10 SMS OR SELF DRILLING SCREWS U METAL EXTERIOR STRUCTURE 88 A Cl KI E' R' R' 0 D BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION REVISIONS REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/01/15 8 REVISED NAME AND ADDRESS 10/27/16 1 NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 N\ 5 R L 041 r'EN0- -y SERIES 185 ALUMINUM IXED WINDOW f* tolir 73" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS WITH RIGID FILLERS 41TATMF" - 4 -1 DRAWN: DWG NO. REVIJ.L. CALE DAIE 08-02357 B k?/ONAC V//'/' llNTSI09/03/14 ISHEET6 OF 12 111110 L. ROBERTO LOMAS RE 1432 WOODFORD RD LEWISVILLE, NC 27023 Luis R. Lomas P.E. 434-688-0609 r1lomasolaomaspe.com FIL No.: 62514 REVISIONS REV DESC IPTION 2 1/2" MIN. A REVISED INSTALLATION DETAILS DATE AP ROVED 06/01/15 R.L. EDGE DISTANCE B REVISED NAME AND ADDRESS 10/27/16 R.L. CONCRETE/MASONRY BY OTHERS 1 1/4" MIN EMBEDMENT11/4" MIN. OPTIONAL 1X BUCK EMBEDMENTSNOTES3 - 7EE SHEET 1 lot CONCRETE/MASONRY BACKER ROD 1/4" MAX._j BY OTHERS 1/4" MAX. APPROVED SHIM SPACE SHIM SPACE SEALANT OPTIONAL Ix BUCK RIGID FILLER SEE NOTES 3 - 7 SHEET 1 RIGID FILLERLL' 3/16" TAPCON EXTERIOR INTERIOR 3/16" TAPCON IN TINTERIOR 3/16" TAPCON BACKER ROD APPROVED RIGID FILLER SEALANT 1/4" MAX 2 1/2" OPTIONAL IX BUCK SEE NOTE 3 - 7 SHIM SPACE MIN. SHEET 1 EDGE DISTANCE EXTERIOR CONCRETE/MASONRY BACKER ROD BY OTHERS 14 1 1 1/4" MIN. APPROVED EMBEDMENT SEALANT JAMB INSTALLATION DETAIL w4 CONCRETEMASONRYINSTALLATION 2 1 /2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETEIMASONRY INSTALLATION SIGNED: 1111512016 MI WINDOWS AND DOORS, LLIC 0WIIIII/w/ 9. L i 650 W. MARKET ST. GRATZ, PA 17030 4f /I NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, SERIES 185 ALUMINUM FIXED WINDOW 0151 NOT SHOWN FOR CLARITY. 73" X 72" NON -IMPACT 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE i FINLESS INSTALLATION DETAILS WITH RIGID FILLERS 041TATVOF DESIGNED IN ACCORDANCE WITH ASTM E2112 DRAWN: lIWG NO. IT J. L. 08-02357 B 0 ONAL l/011111k,01SCALENTSIDATE09/03/14 SHEET 7 OF 12 1L, ROBERTO LOMAS RE Luis R. Lomas P.E. t432 WOODFORD BID LEWISVILLE, NC 27023 FIL No.: 62514434-688-0609 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT BEHIND FLANGE 112" MIN. EDGE DISTANCE 1 1/4" MIN 4: EMBEDMENT 1/4" MAX. SHIM SPACE 10 WOOD SCR EW EXTERIOR INTERIOR lD WOOD SCREW IGID FILLER BACKER ROD & APPROVED SEALANT 1/4" MAX. BEHI SHIM SPACE 1 WOOD FRAMING 1 1/4 " MIN. OR 2X BUCK EMBEDMENT BY OTHERS 1/2" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR2X8UCK INSTALLATION METAL STRUCTURE BY OTHERS BACKER ROD & APPROVED SEALANT BEHIND FLANGE 3/4" MIN 1/4" MAX. SHIM SPACE 10 SMS OR LF DRILLING REW INTERIOR 10 SMS OR SELF DRILLING SCREW BACKER ROD & RIGID FILLER APPROVED SEALANT BEHIND FLANGE 1/4" MAX. FSHIM SPACE METAL STRUCTURE BY OTHERS 3/4" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION EXTERIOR REVISIONS REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/01/15 R. L. 6 REVISED NAME AND ADDRESS 10/27/16 R.L. NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WIT14 ASTM E2112 1/4" MAX. 1 1/4" MIN. 1/4" MAX, SHIM SPACE EMBEDMENT SHIM SPACE rr 1/2" MIN. 3/4" MIN. INTERIORINTl EDGE DISTANCE EDGE DISTANCE I SIGNED: 1111512016 INTERIORNTEI MI WINDOWS AND DOORS, LLCxI vw 650 W. MARKET ST. GRATZ, PA 1703010WOOD10SMSOR GEfq'9. SCREW SELF DRILLING SERIES 185 ALUMINUM FIXED WINDOW WOOD FRAMING —/ SCREWS 73" X 72" NON —IMPACT 0 61 OR 2X BUCK EXTERIOR METAL EXTERIOR FLANGE INSTALLATION DETAILS WITHOUT FILLERS TAT OF 0 BY OTHERS A ... .. BACKER ROD & STRUCTURE BY OTHERS BACKER ROD & DRAWN: REV 0 00' APPROVED SEALANT BEHIND FLANGE APPROVED SEALANT BEHIND FLANGE i . L. 08 —02357 B SCALE DATE 1 SHEETNTS09/03/14 8 OF 12 1111110 JAMB INSTALLATION DETAIL JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE INSTALL_TION L, ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NG 27023 Luis R. Lomas P.E. 434-688-0609 rllornasolr(omaspe.com FL No.: 62514 REVISIONS REV 2 1/2" MIN DESCRIPTION A REVISED INSTALLATION DETAILS DATE APP OVED 06/01/15 R.L. EDGE DISTANCE 8 REVISED NAME AND ADDRESS 10/27/16 R. L. CONCRETE/MASONRY 7 BY OTHERS 1 1/4" MIN. 1 1/4" MIN. EMBEDMENT OPTIONAL IX BUCK EMBEDMENT SEE NOTES 3 — 7 SHEET I CONCRETE/MASONRY BACKER ROD & 1/4" MAX. BY OTHERS 1/4" MAX. APPROVED SEALANT SHIM SPACE SHIM SPACE BEHIND FLANGE OPTIONAL 1X BUCK SEE NOTES 3 — 7 SHEET I 3/16" TAPCON EXTERIOR INTERIOR 3/16" TAPCON T, INTERIOR 3/16" TAPCON BACKER ROD & APPROVED SEALANT BEHIND FLANGE J_ OPTIONAL 1X BUCK 1/4" MAX. 2 1/2" SEE NOTE 3 — 7 SHIM SPACE MIN SHEET 1 EDGE DISTANCE EXTERIOR CONCRETE/MASONRY BACKER ROD & BY OTHERS 4 14 1 1/4" MIN. APPROVED SEALANT EMBEDMENT BEHIND FLA14GE JAMB INSTALLATION DETAIL CONCRETEIMASONRYINSTALLATION 2 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETLIMASONRYINSTALLATION SIGNED: 1111512016 MI WINDOWS AND DoORS, LLC P, L 0650W. MARKET ST. GRATZ, PA 17030 NOTES: SERIES 185 ALUMINUM FIXED WINDOW 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, 73" X 72" NON —IMPACT 0,151 NOT SHOWN FOR CLARITY. FLANGE INSTALLATION DETAILS WITHOUT FILLERS TAT OF2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE 0 , DESIGNED IN ACCORDANCE WITH ASTM E2112 DRAWN: DWG NO, REV 0 "'. tORVD-* 08-02357 B T/ ILE NTS I DATE 09/03/14 SHEET 9 OF 12 ONA, L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023r Luis R. Lomas P.E. 434-60-0609 FL No.: 62514 1/2" MIN. EDGE DISTANCE WOOD 1 1/4" MIN. OR EMBEDMENT BY OTHERS FRAMING 2X BUCK 1/4" MAX, BACKER ROD & SHIM SPACE APPROVED SEALANT BEHIND FLANGE RIGID FILLER 10 WOOD SCREW EXTERIOR INTERIOR 10 WOOD SCREW RIGID FILLER BACKER ROD & APPROVED SEALANT 1/4" MAX. BEHIND FLANGE SHIM SPACE 1 WOOD FRAMING 1 1/4 " MIN, OR 2X BUCK EMBEDMENT BY OTHERS 1/2" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 3/4" MIN METAL STRUCTURE BY OTHERS BACKER ROD & APPROVED SEALANT BEHIND FLANGE 1/4" MAX. SHIM SPACE GID FILLER 10 SMS OR LF DRILLING REW EXTERIOR INTERIOR 10 SMS OR SELF DRILLING SCREW BACKER ROD & RIGID FILLER APPROVED SEALANT BEHIND FLANGE 1/4" MAX, SHIM SPACE METAL STRUCTUR')E_\ BY OTHERSN 3/4" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION REVISIONS REV DESCRIPTION All-1. A REVISED INSTALLATION DETAILS 06/01/15 R. L. B REVISED NAME AND Z WE S 10/27/16 R.L. NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND dOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 1/4" MAX. 1 1/4" MIN. 1/4" MAX. SHIM SPACE EMBEDMENT SHIM SPACE r R GID F, LEIRIGIDFILLER RIGID FILLERRGIDLERIL 1/2" MIN. E l 3/4" MIN. NT, INTERIOR EDGE DISTANCE EDGE DISTANCE SIGNED: 1111512016 INTERIORNTE, MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. r. P, L 0 10 WOOD 10 SMS OR GRATZ, PA 17030 zz- SCREW SELF DRILLING SERIES 185 ALUMINUM FIXED WINDOW 51 SCREWS 73" X 72" NON —IMPACT WOOD F RAMING EXTERIOR METAL EXTERIOR FLANGE INSTALLATION DETAILS WITH RIGID FILLERS T%AVTOF OR 2X BUCK STRUCTURE 0 BY OTHERS ABACKER ROD & APPROVED SEALANT BY OTHERS ABACKER ROD & APPROVED SEALANT DRAWN: RIVrDWGNo J. L. 08-02357 B k'/ONAL BEHIND FLANGE BEHIND FLANGE SCALE NT 09/03/14 OF 1215HEET10 JAMB INSTALLATION DETAIL JAMB INSTALLATION DETAIL., L. ROBERTO LOMAS P. E. WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE INSTALLATION 1432 WOODFORD RD LEWISVILLE, NG 27023 Luis R. Lomas P.E. FIL No.: 62514434-668-0609 rilotnas@irlomaspe.corn 2 1/2" MIN. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS OPTIONAL IX BUCK & 1 1/4" MIN. SEE NOTES 3 — 7 EMBEDMENT SHEET 1 BACKER ROD & APPROVED SEALANT BEHIND FLANGE EXTERIOR BACKER ROD 1, APPROVED SEALANT BEHIND FLANGE OPTIONAL 1X BUCK SEE NOTE 3 — 7 SHEET I CO NC RETE/ MASONRY BY OTHERS 1/4- MAX SHIM SPACE RIGID FILLER 3/16" TAPCON INTERIOR 3/16" TAPCON RIGID FILLER 1/4" MAX. SHIM SPACE 1 1/4" MIN ' EMBEDMENT CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK SEE NOTES 3 — 7 SHEET 1 1 1/4" MIN. EMBEDMENT 4 2 1/2" MIN. L—L DISTANCE VERTICAL CROSS SECTION CONCRETEIMASONRYINSTALLATION 3/16" TAPCON 2 1/2" MIN * EDCE DISTANCE REVISIONS T_ REV DESCRIPTION --;AT' A11R.- A REVISED INSTALLATION DETAILS 06/01/15 R. L. 8 REVISED NAME AND ADDRESS 10/27/16 1 R.L. r1/ 4" MAX. SHIM SPACE RIGID FILLER INTERIOR BACKER ROD & APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL CONCRETEIMASONRYWSTALLATION SIGNED: 1111512016 NOTES: MI WINDOWS AND DOORS, LLC R. 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 650 W. MARKET ST. GRATZ, PA 17030 IN - - . 4i E N o, SERIES 185 ALUMINUM FIXED WINDOW 2. PERIMETER AND JOINT SEALANT BY OTHERS TOBE DESIGNED IN ACCORDANCE WITHASTM E2112 0 51 73" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS WITH RIGID FILLERS o,4'TAT OF *1'4:::' 0 VDRAWN: DWI; NO, J. L. 08-02 57 SCALE -E SHEETNTS09/03/14 21OF1 11111100 L ROBERTO LOMAS P. E. 1432 WOODFORD RD LEWISVILLE, NC 27023 Luis R. Lomas P.E. 434 _666-0609 -p-.m FL No.: 62514 REVISIONS REV DESCR PTION A REVISED INSTALLATION DETAILS OATE 06/01/15 pp OVED R. L. APPROVED B REVISED NAME AND ADDRESS 10/27/16 R. L. SEALANT BEHIND FIN 1/4 .. MIN. EMBEDMENT 6 WOOD WOOD SCREW FRAMING BY OTHERS 1/4" MAX. FSHIM SPACE 1/4" MAX 3/8" MIN WOOD FRAMING BY OTHERS SHIM SPACE EDGE DISTANCE 7INTER/OR 6 WOOD INTERIORSCREW I 1/4" MAX SHIM SPACE 3/8" MIN EDGE DISTANCE 6 WOOD WOOD SCREW FRAMING APPROVED 1 1/4" MIN. BY OTHERS SEALANT EMBEDMENT BEHIND FIN VERTICAL GROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4" MIN. EMBEDMENT APPROVED SEALANT BEHIND FIN EXTERIOR 3/8" MIN EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANTBY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FIN INSTALLATION DETAILS DRAWN: 11111; NO, J. L. 08-02357 SCALE NTS I -E 09/03/14 15111ET 12 OF 12 L. ROBERTO LOMA P. E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434_688-0609 rilomas@trioniaspe.com SIGNED: 1111512016 R. L 0 E T OF EV R Luis R. Lomas P.E. FL No.: 62514 Florida Building Code Online Page I of 3 BCIS Home f Log In 5 User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search 1i 11 , .'[,Product Approval F USER: Public Userdbo- r Product Approval Menu > Product or Application Search > A01plication Lis > Application Detail FL153S3-R3FL # Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email ED MI Windows and Doors 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Category Windows Subcategory Mullions Compliance Method Evaluation Report from. a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Luis R Lomas, PE the Evaluation Report Florida License PE-62514 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Steven M. Urich, PE R Validation Checklist - Hardcopy Received Certificate of Independence FL15353 R3 COI FLC0I.pd Referenced Standard and Year (of Standard) Standard Year AAMA 450 2010 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D https://www.floridabuilding.or,cr/pr/pr app_dtl.aspx?param=wGEVXQw-tDqtH8572qvdWIS... 2/1/2018 Florida Building Code Online Page 2 of 3 Date Submitted Date Validated Date Pending FBC Approval Date Approved 10/16/2017 10/23/2017 10/26/2017 12/12/2017 FL # Model, Number or Name Description 15353.1 5764 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 06-01448B.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant- Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL153S3 R3 AE 512072B.c)d span: 104-1/4". Created by Independent Third Party: Yes I 15353.2 IS764 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No F1-15353 R3 II 08-01439B.odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512063B, df span: 83" Created by Independent Third Party: Yes 15353.3 5765 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01449B.[)d Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 5120738.1)d span: 156-3/8" 1 Created by Independent Third Party: Yes 15353.4 5765 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01440B.I)d Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512064B.r)d span: 83". , Created by Independent Third Party: Yes 115353.5 l CM-18514 I Vertical Aluminum Mullion I Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II OS-01442B,i)d Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 5120666.od length - 83". Created by Independent Third Party: Yes 115353.6 CM-18520 I Horizontal Aluminum Mullion I Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 PQ II 08-01451B.pd Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL15353 R3 AE 512075B.Ddf span - 156-3/8" Created by Independent Third Party: Yes 115353.7 1 CM-18523 I Horizontal Aluminum Mullion I Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01452B.pd Approved for use outside HVHZ: Yes.. Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL15353 R3 AE 512076B.od span - 104-1/4". Created by Independent Third Party: Yes 115353.8 1 CM-18531 I Vertical Aluminum Mullion I Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Installation Instructions FL15353 R3 II 08-01443B.pd Verified By: Luis R Lomas, PE PE-62514 https://www.flon'dabuildinc,.orc, r/pr p_dtl.aspx?param=wGEVXQwtDqtH8572qvdWIS... 2/1/2018 1= _/p _ap Florida Building Code OnlineZn Page 3 of 3 Impact Resistant: Yes Design Pressure: N/A Created by Independent Third Party: Yes Evaluation Reports Other: Max single window size: S2-1/8" x 84". Max mullion FL15353 R3 AE S12067B.pd span - 83" Created by Independent Third Party: Yes 1S353.9 CM-18532 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01453B.Ddf Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL15353 R3 AE 512077B.Ddf span - 156-3/8" Created by Independent Third Party: Yes CM-1853315353.10 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:-No FL15353 R3 II 08-01444B.pdf Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". Max mullion span: 83" Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL15353 R3 AE S12068B,r)d Created by Independent Third Party: Yes 15353.11 CM-18534 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A FL15353 R3 11 08-01454B.pd Verified By: Luis R Lomas, PE PE-62S14 Created by Independent Third Party: Yes Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion span: 156-3/8". FL15353 R3 AE 51207L2 Ea_pAf Created by Independent Third Party: Yes F..-7 FNe-tj Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-182 The State of Florida is an AA/EEO employer. Cooyriaht 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 45S.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If . you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: P"M-9 = 7CRW_ M . LL-=j L--:L-J u= Cr6dil Card, safe https://www.floridabuildin-.oro, ' r app d I.aspx?param=wGEVXQwtDqtH8572qvdWTS... 2/1/2018Pr/p — — t NOTES. 1 ) THE PRODUCT SHOWN HEREIN IS DESICNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO MULLPON. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI WINDOWS AND DOORS, INC. 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW OR DOOR UNIT. 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. 9) MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT. DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH REIASIONS REV DESCRIPTION DATr I AlllR—. A REVISED INSTALLATION DETAILS 06/10/15 R.L. B REVISED ANCHORING NOTES & INSTL DET. 1 06/07/17 R.L. ANCHORING NOTES: 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 2) FOR ANCHORING INTO CONCRETE USE 1/4" ELCO ULTRCON TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT WITH I" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 3) FOR ANCHORING INTO METAL USE #10 SMS OR SELF DRILLING SCREW WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 4) ALL FASTENERS TO BE CORROSION RESISTANT. 5) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS. AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. C. MASONRY STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). D. METAL STRUCTURE —STEEL 18CA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063—T5 FU=30KSI .062" THICK MINIMUM. 6) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS 6" FROM EACH MULLION END AND 12" MAX. D.C. THEREAFTER. STAGGER SCREWS AT EACH WINDOW. TABLE OF CONTENTS SHEET NO. DESCRIPTION I NOTES 2 CONFIGURATIONS AND DP CHART 3 INSTALLATION DETAILS 4 COMPONENTS MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030— - 0 - 3 - 70_ 5764 — VERTICAL MULLION 83" MULLION SPAN GENERAL NOTES DRAWN: DWO No, V. L. 08-01439 SCALE NTS JDATE 01/11/12 1 SHEET I OF 4 I. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 434-688-0609 rIfomasCa)Irfomaspe-rn SIGNED: 1011312017 s F., L o E Nq 0,8 5 A 0 F Z: 00. B jI0NAl_ IIIIIII10 Luis R. Lomas P.E. FL No.: 62514 107 3/8" O"BINED WIDTH W1 83 RAME HEIGHT WINDOW WINDOW MULLION SPAN) 107 3/8" COMBINED WIDTH 107 OMBINED WIDTH W1 W2 - 83" FRAME WINDOW HEIGI- VINDOW MULLION SPAN) L_ L/_ IL I W I W2 83" WINDOW FRAME HEIGHT WINDO14 WINDOA MULLION SPAN) Wl W2 107 3/8" COMBINED WIDTH Design pressure rating st) Mullion span (in) Tributary width (in) 18.13 25.50 36.00 42.00 48.00 52.13 25.00 120.0 120.0 120.0 120,0 120.0 120.0 37.38 120.0 120.0 120.0 120 O 120.0 120,0 49.63 120.0 98.3 81.2 76.9 75.2 76.1 62.00 71.0 52.2 39.7 35.9 33.4 32.3 65.63 59.6 43.7 33.0 29.6 27.4 26.3 227i2 B j 3. 2j.4 21.8 19.9 19.0 i 2' 211 3 LARGE AND SMALL MISSILE IMPACT, LEVEL D, WINDZONE3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT INCLUDE FLANGE 107 3/8" OMBINED WIDTH IN I W2 - F T_ 83" FRAM E ZWINDOW 111DOW HEIGHT MULLION SPAN) L 07 3/8" WI COMBINED WIDTH 1 - W2 T_ 83 11 WINDOW FRAME HEIGHT WINDOW WINDOW MULLION S PAN lull LW1 -11- COMBINED W2 - 107 3/8" WIDTH REVISIONS I REV I DESCRIPTION I DATE I APPROVED I A REVISED INSTALLATION DETAILS 06/10/15 1 R.L. 13 REVISED ANCHORING NOTES Ar. INSTIL D -6/01/17 rR.L. 107 3/8" COMBINED WIDTH W, W2 83" FRAME HEIGHT WINDOW WINDOW WINDOW MULLION SPAN) L IL --- L-i Wl -1 W2 107 3/8" OMBINED WIDTH APPROVED CONFIGURATIONS MULTIPLE UNITS MAYBE MULLED TOGETHER AS LONG AS COMBINED WIDTHDOES NOTEXCEED 107318"AS SHOWN HEREIN. Desiqn pressure ratinct (Dsn With rebar Mullion Tributary width (in) span (in) 18.13 25.50 136.00 42.00 48.00 5243 25.00 120.0 120.0 120.0 120.0 120.0 120.0 37.38 120.0 120.0 120.0 120.0 120.0 120.0 49.63 120.0 98.3 81.2 76.9 75T 75.1 62.00 95.2 70.0 53.3 48.1 44.8 43.4 65.63 80.0 58.6 44.2 39.7 36.7 35.3 7211 1 2 l 1 29.2 26.7 25.5 377 1 27 5 20, '1 1 17.7 1 16.0 1 15.1 LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT INCLUDE FLANGE MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 - VERTICAL MULLION 83" MULLION SPAN APPROVED CONFIGURATIONS AND RATING CHARTS DRAWN: DWI; NO. I REV V. L. 08-01439 8 SCALE NTS I OATE 01/11/12 1 SHEET 2 OF 4 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434_688_0609 rjjoM-@1r1omaspi,.co. SIGNED: 1011312017 F 11/10NAL Luis R. Lomas P.E. FIL No.: 62514 1 " MIN EDGE DISTANCE MASONRY/CONCRETE BY OTHERS 1 1/4 MIN. EMBEDMENT T tj 1/4" ELCO ULTRACON TAPCON 5ECT5796 CLIP OPTIONAL REBAR I — MT000022 CLIP 10 woo 1 318" EMBEDM w 1/2" MIN. 2 EDGE L 0 DISTANCE VERTICAL CROSS SECTION MASONRYICONCPETE AND WOOD FRAMING INSTALLATION NOTE: CLIPS MAY BE USED IN MASON RY/CO NCR ETE OR WOOD FRAMING, SUBSTRATE. SECT5764 MULLION D SCREW MIN. ENT ODD FRAMING/ X BUCK Y OTHERS REVISIONS REV D CRIPTION DATE 1 -1- A REVISED INSTALLATION DETAILS 06/10/15 R.L. 13 REVISED ANCHORING NOTES & INSTL DET. 06/07/17 R.L. MT000022 CLIP r I _Ilr #10 SMS OR SELF DRILLING SCREW METAL 1/2" MIN. STRUCTURE EDGE BY OTHERS DISTANCE VERTICAL CROSS SECTION METAL INSTALLATION MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 — VERTICAL MULLION 83" MULLION SPAN INSTALLATION DETAILS DRAWN: V. L. I DWG I'D 08-01439 SCALE NES JDAT' 01/11/12 1 SH"T 3 OF 4 L. ROBERTO LOMAS P.E. 1432 WOODFORD BID LEWISVILLE, NG 27023 434-688-0609 SIGNED: 1011312017 W.. LO 4 GEN p Wt AiCO Fj Z 0. ZOO) O/OM Luis R. Lomas P. E, Fl- No.: 62514 2.140" —1 1. 125" L SECT5764 MULLION ALUMINUM 6005-T5.125"THtCK 0.688" 1.531 I RF-U `EBAR 16 GA (.062) GALVANIZED STEEL NOTES: 1. CLIPS MAY BE USED IN MASONRY/CONCRETE OR WOOD FRAMING SUBSTRATE. 2. FOR WOOD & METAL INSTALLATION USE ALL FOUR ANCHOR LOCATIONS. 3. FOR CONCRETE INSTALLATION USE 2 ANCHOR LOCATIONS ONLY WITH 3 1/4" SEPARATION BETWEEN ANCHORS. i 0.843" T-- 3.2 61 1.375" 0.625" c)- 3.250" 4.000 MT000022 CLIP 16GA 063-) —GALVANIZED STEEL SEE NOTE 2 & 3, THIS SHEET, 3,750" 2.189" 0.375" 0.8 43" 1F---]-Fj 2X 00.210" 1.562" F 1.5, L— SECT5796 CLIP FOR WOOD FRAMING INSTALLATION ALUMINUM 6063-T5.125" THICK REVISIONS REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS C)6/1()/15 R.L. 0 REVISED ANCHORING NOTES & INSTL DET. 06/07/17 R.L. 3.750" 1.000" — 0.375" 0 422" 0.8 1 43" 2,031" 2,1115" F-- 11 111 _ LLe- I SECT5796 CLIP 2X 00.210" FOR CONCRETE INSTALLATION ALUMINUM 6063-T5.125" THICK Ml WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 — VERTICAL MULLION 83" MULLION SPAN COMPONENTS DRAWN: 77111 --- V. L. 08-01439 c.. NTS l)A" 01/11/12 SHEET 4 OF 4 I. ROBERTO LOMAS P.F- 1432 WOODFORD RD LEWISVILLE, NC 27023 434-668-0609 SIGNED: 1011312017 0 10 51 p TAT Or o. Al A Luis R. Lomas P.E. FIL IN ..: 62514 Florida Building Code Online Page I of 3 WE FA= K=- I Nnz= = 11 3CIS Home I Log In I User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search HMO . a 115roduct Approval K USER: Public Userpr Product Approval Meng > Product or Application Search > Application Lis > Application Detail lg 77-7-77 FL # FL13223-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer James Hardie Building Products, Inc. Address/Phone/Email 26300 La Alameda Ste. 250 Mission Viejo, CA 92691 909) 349-2927 pingsheng.zhu@jameshardie.com Authorized Signature Pingsheng Zhu c pingsheng.zhu@jameshardie.com Technical Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana, CA 92337 909) 349-2927 pingsheng.zhu@jameshardie.com Quality Assurance Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana, CA 92337 909) 349-2927 pingsheng.zhu@jameshardie.com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Ronald 1. Ogawa the Evaluation Report Florida License PE-24121 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By John Southard, P.E. W Validation Checklist - Hardcopy Received Certificate of Independence FL111223 R4 COI RIO - Certificate of Inde[)endence.lpdf Referenced Standard and Year (of Standard) Standard ASTM C1186 ASTM E330 Year 2007 2002 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL13223 R4 EQuiv RIO-2692B-17 ASTM C1186 eaulvalency.pd http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvRk6bsvZ66FC... 2/6/2018 Florida Building Code Online Page 2 of 3 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 06/09/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL # Model, Number or Name Description 13223.1 — — — TiCempanel Siding fiber -cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13223 R4 II cempariel-installation.odf Approved for use outside HVHZ: Yes FL13223 R4 11 NOA 17-0406.06.pdf Impact Resistant: Yes FL13223 R4 11 RIO 2689-17 Panel to Furrinq,l)d FL13223 R4 II RIO-2686-17 Panel Wood Metal Frame.pdDesignPressure: N/A Verified By: Ronald 1. Ogawa 24121Other: For use inside a HVHZ install in accordance with NOA 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06.r)d FL13223 R4 AE RIO 2689-17 Panel..to..Furrinq.pd FL13223 R4 AE RIO-2686-17 Panel Wood Metal Frame.Dd Created by Independent Third Party: Yes 13223.2 ___HardePanel Siding fiber -cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13223 R4 11 HardiePanel-Installation.[)df Approved for use outside HVHZ: Yes FL13223 R4 11 NOA 17-0406.06.pdf Impact Resistant: Yes FL13223 R4 II RIO 2689-17 Panel to Furrino.Dd FL13223 R4 11 RIO-2686-17 Panel Wood Metal Frame,DdfDesignPressure: N/A Verified By: Ronald 1. Ogawa 24121Other: For use inside a HVHZ install in accordance with NOA 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06.od FL13223 R4 AE RIO 2689-17 Panel to Furrj FL13223 R4 AE RIO-2686-17 Panel Wood Metal Frame.pdf Created by Independent Third Party: Yes 13223.3 Prevail Panel Siding fiber -cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13223 R4 11 NOA 17-0406.06.pdf Approved for use outside HVHZ: Yes FL13223 R4 II Prevail-Panel-Installation..12df Impact Resistant: N/A FL13223 R4 11 RIO 2689-17 Panel to Furrina.Dd FL13223 R4 II RIO-2686-17 Panel Wood Metal Frame.pdfDesignPressure: N/A Verified By: Ronald I. Ogawa 24121Other: For use inside a HVHZ install in accordance with NOA 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406,06.i)d FL13223 R4 AE RIO 2689-17 Panel to Furring.pd FL13223 R4 AE RIO-2686-17 Panel Wood Metal Frame.Ddf Created by Independent Third Party: Yes FEE F-i-nd Contact U :; 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-182 The State of Florida is an AA/EEO employer. Copyriaht 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuart to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: m W i7a 99 0 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvRk6bsvZ66FC... 2/6/2018 Florida Building Code OnlineZ= Pao,e 3 of cree dh Card http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvRk6bsvZ66FC... 2/6/2018 Florida Product Approvai HardiePanelO Siding For use inside HVHZ: o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami -Dade County Florida NOA 17- 0406.06. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. For use outside of HVHZ, o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Reports RIO-2686-17 or RIO-2689-17. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. VV CLEARANCES Install siding and trim products in Maintain a rriinimum 1 " Maintain a minimum 1 2" clearance At t ' he Juncture of the roof and vertical maintain a 1 14- compliance with local building code 2" clearance between between Jarnes Hardie products suraces, flashing and counterflashing clearance between requirements for clearance between Jamles Hardieg and decking material. shall be nstall d per the roof ing manufacturer's instructions. Provide a the bottom of James Hardie products and the bottom edge of the siding and products and paths, Figure 7 minimum 1 "- 2" clearance between horizontal flashing, the adlacent finished grade, steps and driveways. the roofing and th ottoT edge of the Do not caulk galp. stud siding t.r siding and trim. Refer to fig. 3 on Figure 5 Figure 6 Figure 8 page 1. siding FIT Lcl , K, 01- f Pi 77 T7171, ITT 11 -V-Tmin. E'141 - 2muIash. - 0 M deck material joist 2" Do not bridge flocrs with Hardiel'anell siding. Horizontal joints should always be created between floors (fig. 0). Resistive Darner Framing Figure 10 FloonngHonzntal Trim rr Sheathing fascia rdiePanelo gutter and end cap BLOCKED PENETRATIONS Penetrations such as hose bibs and holes I !?` or larger such as dryer vents should have a block of trim around point of penetration. GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, oalvani2ed, or stainless steel. Dectro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot -dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie prodiuc s near the ocean, large bodies of water, or in very humid climates, Consult applicable product evaluation or listing for correct fastener type and placement to achieve specific design wind loads. NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable compliance documentation. Drive fasteners perpendicular to siding and framing. Fastener heads should fit snug against siding (no air space). (fig, A) Do not over -drive nail heads or drive nails at an angle, If nail is countersunk, fill nail hole and add a nail. Cig. B) For wood framing, under driven nails should be hit flush to the pankwth a hammer Clor steel iraming, remove and replace nail). NOTE: Whenever a structural member is present, HardiePlank snould be fastened with even spacing to the structural member The tables allowing direct to OSB orplywood should only be used when traditional framing is not available. Do not use aluminum fasteners, staples, or clipped head nails. Snug Flush J. =\ Countersunk, fill & add nail Figure A Figure B do not under drive nails DO NOTSTAPLE KICKOUT FLASHING Because of the volume of water that can pour down a sloped roof, one of the most critical flashing details occurs where a roof intersects a sidewall. The roof must be flashed wit step flashing. Where the roof terminates, install a i to deflect water away from the siding. It is best to install a self -adhering membrane on the wall before the subfascia and trim boards are nailed in place, and then corne back to install the kickout. Figure 11, Kickout Flashing To prevent water frorn durnping behind the siding and the end of the roof intersectiom install a "kickout" as required by IRC cod-, R905.2.8.3 ..flashing shall be a min. of 4i' high and 4" wide." James Hardie recommends the kickout be angled between 00' - 110' to maximize water deflection Figure 11 Step fias in membrane me it lashing C'm ejge PNEUMATIC FASTENING James Hardie products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachment on the pneumatic tool is recommended. his will 1heip control the depth the nail is driven. If setting the nail depth p!ov-.s difficult, choose a setting that under drives lie nail. (Drive under driven nails snug w.th a smooth faced harnmer - Does not apply for installation to steel framing). HS1236-P2/3 8113 db Hardie Pane 1'"Z,29, VeilicalSiding JamesHardie EFFECTIVE SEPTEMBER 2013 INSTA IfON REQUREMENTS RESIDENTIAL SINGLE FAMIl V ONLY - PRIMED & COLOIRDLU7 DRODLJCT S Pmn,,James aroln-co- for 'the most recent versinn. SMOOTH CEDARMILLO - SELECT SIERRA 8 STUCCO IMPORTANT, FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPUCABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY AFFECT SYSTEM PERFORMANCE, VIIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY, BEFORE INSTALLA11ON, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS. INSTALLATION OF HZ11 OTM PRODUCTS OUTSIDE AN HZ1 FLOCATION MILL VOID YOUR WARRANTY, TO DETERMINE WHICH HARDIEZONE APPLIES TO YOUR LOCATION, VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-734,3 STORAGE & HANDLING: Store flat and keep dry and covered prior to installation. Installing siding viet or saturated may result in shrinkage at butt joints. Carry planks on edge, Protecf edges and corners from breakage.lmes Hardie is not responsible for damage caused by improper storage and handling of the product. j CUTTING INSTRUCTIONS OUTDOORS INDOORS 1 . Position cutting station so that wind will blow dust away from u&:i, 1. Cut only using scoie and snap, or shears (manual, electric or pneumatic), and others in wA, ng area. 2. Position station in well -ventilated area 2. Use one of the following methods: a. Best: i. Score aid snalp ii, Shears (manual, electric or plieurnatic) - NtRIER use 2 power saw indoors b. Better: i. Dustreducing circular saw equipped with a - NRER use a circular saw blade that does not caln, the Hardie -Blade sail blade tradema, < Hardie3lade' saw blade and HEPA vacuum exliaction NEVER dry sweep - Use wet suppression or HEPA Vacuum c. Good: i. Dust red -icing circular savivoith a HardieBlade savv blade k (only use for low to moderate cutiing) Important Note: For maximum protection towestrespirable dusrtPr3duc1ior I, James HardierecommandS 31vrays using Test"-Ievel cutting meMods where feasible. NIOSH-approved respirators can he Used in conjunction with above outing practices to further reduce dust exposo es * Additional exposure information is available a- ifi,,.,.vqamesbardie,com io hallpyou determine the most appiopt ite. rutting method foryour job i equirements, If concem still exists about exposur levels or you d,-, not comply vAth the above practices, you should always ecoriSLIK a oualffic d industrial hyqiai list or contact James Handle for further information. e SXS G5 GENERAL REQUIREMENTS: These instructions to be used lor residential single lamily installations only. For Commercial / Mufti -Family installation requirements go to v,,%i.JamesHardieComrner.ial,,-,om HardiePaneri vertical siding can be installed over braced wood or steel studs sparced a maximum of 24" o.-c. See genemal fastening requirements. Irregularities in framing and sheathing Gan mirror through the finished application, James Hardie recommends installing HardiePanel on a capillary break (rainscreenitiirring) as a best practice. Information on installing James Hardie products over loam can be located in JH Tech Bulletin 19 at wtviot]. iamehar fie.com A water -resistive barrier is reo.Jred in accordance with local building -code requirements, The water -resistive barrier must be appropriately installed kvithu penetration and junction flashing in accordance with local building code requirements. James Hardie will'ssume no tesPonsibility for water infiltration. James Hardie does manufacture Hard ieViiif,ap,r Weather Barrier, a non -woven rion-perforated houseviralpl, which complies with building code requirements, When installing James Hardie products all clearance details in figs. 5,6,7,8,9,10&11 must be followed, Adjacent finished orade must slope away from he building in accordance with local building codes - Ilpically a minimurn of 6" in the first 10'. Do not install Jam -es Hardie products, such that they Zy remain in contact with standing water. HardiePanel vertical siding rinay be installed on Vertical wall applications only. DO N16T use HardiePariel vertical siding in Fascia or Trim applications. Some ppflcation are not suitable for CiolorPlus. Refer to ColorPlus section p age 3. DO NO I use stain, oil/al d base paint, or povvder coating on James Hardie"' Products. For larger rojec , ling commercial and multi -family projects, imhere the span of the wall is significant in length, the designer and/or architect should take into consiT ration the coeff cient of thermal ex ansion arid moisture movement of the product in their design. These values can be found in the Technical Bullet:n 8 "Expansion Characteristics" atvAvr,1.JameErdie.com. INSTALLATION: Fastener Requirements Joint Treatment Position fasteners 3/8" from panel edges and no closer than - Vertical Joints - Install panels in moderate contact (fig. 1), alternatively 2" away from corners. Do not nail into corners. joints may also be covered with battens, PVC or metal jointers or HardiePanel Vertical Siding Installation caulked (Not applicable to ColorPlus' Finish) (fig. 2). Framing must be provided at horizontal and vei tical edges for nailing, * Horizontal Joints - Provide Z-flashing at all horizontal joints (fig. 3). HardlePanel vertical siding must be joined on stud. Figure 2 Figure 3 water -resistive barrier water -resistive barrier Double stud may be required to maintain minimum edge ate nailing distances, 2 4 stud 2 x 4 stud barg s i r, t v a wa 'ee-resistva ne, barrier I —upper panel uoner panelFigure1 1/4" nan n , I 11,1' water -resistive barrier sheathing _ keep nails 3/8 " min. from panel - edges plate —I keep fasteners 2" away from corners HardiePanel C vertical siding 3 C, moderate contact Batten Joint "H" Joint water -resistive barrier Pw 2 X 4 stud it leave appropriate p between panels, then caulk* Caulk Joint Wit applicable t, Colol lus Finish) Apply caulk in accordance with cauk mamr1w,turer s wr;tten application instiruclions. or additional inlormPtion on HardieWrapT" Weather Barrier, consult James Hardie at 1-866-41-lardie or viun.,Amhardievirap.com o no, Caulk 4 Z-flashing t 2-flasting f raive Innard lower Danel Figure 4 Recommendation: Vvren i-stalli.! ig Sierra 8, orovi,a a StUd at p rcl jnints to avoid railinn rhrough orooves. WARNING: AVOID BREATHING SILICA DUST annes Hardiel products cirtain.resDinable crystalline silica, which is Krown m the State of Callfornia to cause cancer and is considered Ly IARC aid NII& to be a cause of cancerfirc.-ri snrre occupational sources. Bre2thing e,,'essive amounts afreprable silica dust call also cause 2 disabling and pritential1v fatal lurp ilspase ralled srlpos!s, and has been flilked ,Ajith other disease,,. Snme stjdies S ggas' smo knq may increase these risks. Duringinstallatonorhandling. ill work in sitdcor areaviirth ample venniation: use fiber cement shears for cu-mg or wlpre not fea3ible, ti e a HardieBladp say., blaoa and djst-rduc.ng circularsaw attacheri to a HEPA vartium: 3) viarn oi rprs in the immediate area: (4) wear a proccerIv-fiftec, NJOSH-approved dust mask o, respirator ist irQ. N-951 :r. acrorcarce imth applable government fegula-.ions ano mariLlactuner ir tr 3tiors tc f trier imit able silica exr-isures. Durino Clean-up, use HEPA vacuums or ivet cleariuF melthrocs - never dry sweep. Fir further information, refer to our installation instructions and M2tenaI Satery buts Sibeet. available at A DIF 0, -KC-942-7343). FAILURE ADHERE TO OUR WARNING--, MSDS, A.ND INSTRUGMINS MAY LEAD TO SERIOUS P RSONAL If, URY DR. DEATHvvm..amesrbaidie.com or by calling 1-800-9, LAR E HS-1236-P1/3 1/13 ffff-7-14-9 CAULKING For best result use an Elastomeric Joint Sealant complying with ASTM 0920 Grace NS, Class 25 or higher or a Latex Joint Sealant complying with ASTM C834. Caulkina/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note: OSI Quad as well as some othercaulking manufacturers do not allow tooling. DO NOT caulk nail heads when using Coioi-Plus products, refer to the ColorPlus touch-up section CUT EDGE TREATMENT PAINTING Caulk, paint or priine all field cut edges. DO NOT use stain, Dil/alkyd base paint, or powcer coating on James Hardie Products. James Hardie products James Hardie touch-up kits are required must be painted within 180 days for primed product and 90 days for unprimed. 100% acrylic tooccats are to touch-up ColorPlus products. recommended. Do not paint when wet. For application rates refer to paint manufacturers specifications. Back -rolling is recommended if the siding is sprayed, COLORPLUSO TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE Care should be taken when handling and cutting James Hardie®R ColorPlus@ products. During installation use a wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product, then rinse with a garden hose. Touch up nicks, scrapes and nail heads using the Color-Plu0 Technology touch-up applicator. Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with nevit HardiePaneP siding with ColorPlus Technology. Laminate sheet must be removed immediately after installation of each course. Terminate non -factory out edges into trim where possible, and caulk. Color matched caulks are available frorn your ColorPlusi" product dealer. Treat all other non -factory cut edges using the ColorPlus Technology edge coaters; available from your ColorPlus product dealer. Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up, will not be covered under the James Hardie ColorPlus Limited Finish Warranty. 1 he following outlines the recommended applications for ColorPlus and Primed panels. Not all designs will be suitable for every application: Exposed fasteners or battens is the recommended application for ColorPlus panel products Do not use touch-up over fastener heads for smooth ColorPlus products - primed panel recommended For ColorPlus panel applications that require fasteners in the field, it is acceptable to use touch-up over fasteners for Cedarmill and Stucco panel only, but correct touch-up application is important. Some colors may show touch-up when applied over fasteners. Trim is recommended to cover joints when appropriate. PAINTING JAMES HARDIEO SIDING AND TRIM PRODUCTS WITH COLORPLUS" TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: Ensure the surface is clean, dry, and iree of any dust, dirt, or mildew Repriming is normally not necessary 100% acrylic topcoats are recornmencled DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardi0' Products Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature RECOGNITION: In a-0idance with 1011-ES Evaluatm Report ESP.---844, HardieP2ndlq) vertical siding is reMgni2ecl as a suitable altPinate to that spedfM n the 2036.20001, & 2-012 International Flesidential Code to, One -and Twc-Farinily Dwellings andlie 2006, 2009; & 2012 Internati-nal Building Code. Hai dieParel vertical siding is also iecognl2ed fo; applical' on the follow! no : City o, LO, Angeles Research Repcn, No. 24862, State of Florida 7 7I'sling FFL#889: Dade Courty, Flonda NOA No. .02-.0729.02. U.S. DePt. oi HUD '%Iiiterials Release 12E3c, exas Denartmerit of Insurance Product Evalua-cri EC-23, C4 of New, York MEA 223-93-1), and California DSA PA-C19. These douments should also be consulted for additional in, I ornnation concerning the suitability if this procuct for spa'ific applications. C-) 2,313 James Hardie Building Products. All rights reserved. TM. SM, and S denote trademarks or registered trademarks of Jannes HardieTechnology Limited LF is a registered ademark of James Hai die Technology Limited, Additional Installation Information. Warranties, and Warnings are available ^t JamesHardle www,jarneshardie.com [01 HS1236-P3/3 6/13 MAMIDA 41CC1awACCREG DLABORATORY July 30, 2017 Pingsheng Zhu, P.E. Product Compliance Engine James Hardle:Building Products 10901 Elm Ave, Fontana, CA 92337 Re., NOA-17-0406.06 Relative to FBC 2017 Project. RIO-2679AA 17 Dear Pingsheng: After revievvof the 2017 FBC, it is rny opinion that thecurrent NOA-17-0406.06 is in Compliance with the 2017 Florida Building Code. Referen(:ed Sta6i:16HS in the 2,017 FBC, 1, Wood: AWC NDS-2015 & SDPWS-2015 Z Structural Loads. ASCEISEI-7-10 3. Concrete. ACE-31 BA4 4. fAasonry:TtilS402-20161AC.1536-1/ASCE--13,, 5. Structural Steel, AISC 360-10 (including manual of steel construcfion 2010 (14'wedifical)) 6- Cold -formed Steel- AISI IDO-1 2 7, Aluminurn: ADM-1-2015 In addition, I am Making thefolloviiing Statement of' Independence. as requested; 1 Ronald 09awa, does not ha,e nor does it intend to acquire or VH1 it acquire any finan wil interest in any company manufacturing or distributing products for which evaluations are issued. 2. Ronald Ogawzi is not Owned, operated or controlled by.any connpany manufacturing or distributing products 'evaluzifes or inspect, 3'. Ronald Ogaw.a Inc: does not have.' nor w I ! I] tt acquirea financial interest inany company manufacturing or distributing P, oducts for whichreports are beirio issued.. 4, Ronald Ogawa does not have, nor wi 1 11 it acqu'r' financ, Iea_ fa interest in 61y Other entity involved fn the app roval process of the product - Should you have any questions on anything, please, contact me. Sincerely, v Ronald 1. Cigawa, P. RI Ogawa & Associates, Inc, 1AS Laboratory Approval, TL- 360 IAS Quality Control Agen ' cv. AA-705 CRRC.Approved Testing Laboratory for Solar Reflectance. and Emissivity State of Florida Approved Validator and Third Pa I rty Qua . li . ty Control Agency 714)29.2-2602 ron,@Hoga%ia.com CC-, Roger 09awa - R.1 Cigawa & Associates, Inc. Karen 09awa - Rf Ociawa. & Associates, Inc. itV- (31 61r; 4! FLO RO kNAN- Lab Address:. 1985 Sampson Avenue, Corona, CA 92879 a Phone (714) 321-4939 * rax (714' -1815 com Mailing Address: 16835 Algonquin St- #443, Huntington Beach, CA 92649 * Phone-(102) 491-371.0 Fax (714) 909-:1815 &mll* dg,,bbVegJM-mVa.Wm Engineering v Quality Control * Prod uct,Development v Inspections * Code Consulting: E-Ypen Witness e Testing, MIAMI- MIAMI-DADE COUNTY M3 PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Mam Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) v ww.mianiidade.gov/economy James Hardie Building Product, Inc. 23 10901 Elm Avenue Fontana, CA 92337 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). ZP This NrOA shall not be valid after the expiration date stated below. The Nfiami-Dade County Product Control Section In Miarni Dade County) andJor the AHJ (in areas other than NEarni Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: "Hardie", "Cem" and "Prevail" Planks and Panels Fiber Cement Siding and Soffit APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardlePlank-, CemPlank Prevail Lap Siding, HardieSoffit, CemSoffit Panel; Installation Details Wood/N4etal Stud Construction", sheets I through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I. 0gawa, P.E., bearing the Nhami-Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MssELF, IMPACT RATING: Large and Small Missile Impact Resistant1 LABELING: A permanent label with the manufacturer's name or logo, Plant City, Florida, and theZ following statements: "ASTM C 1186 Type A complianf 'and "Miami -Dade County Product Control Approved" is to be located on each siding plank or panel and per FBC 1710.9.2 and 1710.9.3 on soffit panels. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has beenno change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising Or any other purposes shall automatically terminate this NOA. Failure to complyArith any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 15-0122.04 and consists of this page I and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 17-0406.06 WKAMI-0 Expiration Date: May 1, 2022 Approval Date: May 4,2017 7 2_ 1117 Page I James Hardie B"dinj! Products, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS '"Submitted under NOA 4 13-0311.0 7" 1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; z:1 HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; 2-- Installation Details Wood/Metal Stud Construction", sheets I through 12 of 12, dated 04/24L?013, prepared by the manufacturer, signed and sealed by Ronald 1. 0gawa, P.E. B. TESTS "Submitted under NOA # 13-03-11.0 7" 1. Test reports on 1) Uniform Static Air Pressure Te:st, Loading per FBC TAS 202-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of HardiePlank, HardieSoff-it and HardiePanel, prepared by Intertek Testing Services NA LTD, Test Report No. 100733361COQ-004, dated 08/24/2012, with revision I dated 04/25/2013, signed and sealed by Rick Curkeet, P.E. Submitted under NOA # 02-0729.02" Laboratory Report Test Date Sianaturein 2. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves P.E. 3. ATI 16423-2 PA 202 & 203 03/18/96 A. N. Reeves P.E. 4. ATI 16423-3 PA 202 & 203 03/18/96 A. N. Reeves P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS "Submitted under A10A # 15-0122.04" 1. Statement letter of code conformance to the 5th edition (2014) FBC issued by Ronald 1. Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald L 0ga-wa, P.E. APo4r7/7017 Carlos M. Utrera, P.E. Product Control Examiner NOA No. 17-0406.06 Expiration Date: May 1, 2022 Approval Date: May 4, 2017 E-1 PIE WALL A. PRODUCT RENEWED as complying with the Florida Building Code NOA-Ho. 17-0406.06 Expiration Mate 0 5 112022 By Miaml-Dacfe Product Control ft 46 WALLLENGTI-I Stud Spacing at 16" O.C. 13-4— 1 1 1 41 C7 7!: W, Nails at 16' O.C. (typ.) 3/8- Minimum Edge DistarICL- Sheathing fastener, as desctibed in Note I Panel fastener, as described in Note 2 HardiePanel, Cempanel, r Prevail panel Siding Water -resistive barrier per Florida Buil&ng Code Section 14042 518" thick / 5 ply APA rated plywood sheathing fastened in accordance wAh Florida Building Code Section 2322.3 2" X 4'8-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. QNCAMPTL SEE Hardiel'anel&, Mpa 4' & DETAILA Prevailt Panel Siding materialsare T-- nonasbestos fiber-coment products 6/8" ttick 16 ply APA rated tested in accordance! with ASTM plywdod sheathting in cl 186 Grade 11, Type A and meeting k acmdance with Florida Building Code Section the requirements of the Florida Building Code. 23223 X j-AMWQMR-SjP-N-S Water-resisfive Width Length Thickness barrier per Florida 4' 8,9,10, 5/161, Building Code Section 1404.2 pFVLQbLFREWLPM RA -TONG 2X 4" S-P-F Installation Design Pressure Wood Studs Wood Studs -76 psf HardiePane[, Impact Resistant - Cernpanel, Planks installed over &8" thick / 5 ply aECJB0-N-1$M--$ PMV211 Panel APA rated plywood sheathing SIding 1-10N. DETAILSLj.F DIF PANEL PREVAILPAMNEP,, PEN SIQ-LN-Q INSTALLA feesAlljnstAlafionshallbedoneInconformancewM-i this Notice of AWeptanm the manufactu installation recommendations, and theapplicable sections of the Florida Building Code. Wood studs where HardiePariel, Cempariell, Prevail Panel Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.OA Rote 1] 5f&'thickJ 5 ply APA rated plywood sheathing shall be attached to the srtuds in accordance YAth Florida Building Code Section 2322.3. The siding panels shall be installed over 5/8" thick 16 ply APA rated plywood ttheathing supported by a minimum of 21,)(4" S-P-F wood studs spaced a maximum of LNote 2] The siding panel fastener:shall be a 2" long, 0.223" head diameter, 0.09Z, shank diameter, corrosion resistant siding nall; the fasteners shall be spaced at 6'0.0. at panel edges and intermediate studs; the fasteners shall be driven through the 5/8" thick 15 ply APA rated plywood sheat:h lng into wood studs located at 16!'O.C- Fasteners shall have a minimum edge dietar ce of 3/8" and a minimum clearance of 2" from comers. i Creator: E. Gonzales HARDIEPANEL, CEMPANEL, PREVAIL PANEL INSTALLATION DETAILS WOOD MID CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 SIZE FSCM No I DVJG NO RW A PNI--PL-K-SOFF I I Dat6:412412013 I SHEET 1 OF 12 Famner Spacing per Florida Building Code.Section 2322.3 F- E ft vxWji* with *tFkWid* adWas Caft A.-Vww No %-01WZ- 6.001n. Fastener Spacing per Florida Building Code Section 2322,3 M,OMCT REVISED PRODUCT RENEWED S co"Wbing V/ft the Florida as complying with the Florida B"adbv CO& Building CodeAceWA!xb No 13- 94 f " e7 NOA-Nb. 17-0406.06 E- Ir-tio- -05' 112022 L Myal-Va d.cot ."tr.1 E113AM—INQ NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-112!' 16d COMMON NAILS (Z PER TOP AND BOTTOM CONNECTION) THE WALLAND SOFrJT FRAMESARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE NOMINAL 518" THICK/ 5 PLY APA RATED PLYWOOD SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA BUILDNG CODE SECTION 2322.3 ZAAMN-ci THE PANP-L IS FASTENED WITH 2" LONG, 0,223" HEAD DIAMETER, 0.092! SHANK DIAMETER, CORROSION RIZS18TANT SIDING NAILS, PLACE NAILS 6" O.C. AT PANEL EDGES AND INTERMEDIATE STUDS C12dding Framing Sheathing A. 6 S 0A 310NA FOR METAL AND WOOD STUDS, PROVISIONS FOR OIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) I WALL iLIGHT Lk Flovida M, PRODUCTRENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 WALL LENG" Stud $Pacing at 16" O.G. SEE Hardie?anelilti, Gernpanel(M, & 171'evaitS DETAIL. A Panel Siding materials are nonasbestos 5/8" thick / 5 ply APA rated fiber -cement products tested in plywood sheathing fastened accordanrae with ASTM C1 186 Grade 11, to metal studs as described Typ e A and meeting the requirements of eA'] in Note 1 the Florida Building Code, f co-Wriff **h smidih i 4 % R, Nj.LQIMRNSWQM 0 11" COIL* Water -resistive it Width Length Thickness zpy of No, barrier pet Florida 41 8,9,10' 5/161, Bulld(ng Code Section 1404.2 P_ 12 LqNY-R- 5; LtR Ei -13 tk Tj N_ S iSTATEFct \ . y Installation Design Pressure 20ga, 3-5/8" X 1-6181. Metal Studs -104 psf Metal C-stud t0A- Impact Resistant — fill Hardieftnel, Panel installed over 6/6" thick 5 plycompanel, APA rated plywood sheathing Nails at G" O.C. (typ.) Prevail Panel 318" Minimum Edge Distance Siding Sheathing fastener, as described in Note 1. Panel fastener, as described In Note 2 HardiePanelTo Siding wat r-reslstive barrier per Norlda Building Code Section 1404,2 518" thick / 5 ply APA rated plywood sheathing fastened to metal studs as described in Note 1. Expiration RateO5101/2022 2098, 3-6/811X 1 518" Metal C-StUd By The wall and soffit frames are to be designed Miaimi-,Dade Product Control by the Architect or Engineer of Record In I Wrripliance with the Florida Building Code. hone All instagation shall be done In conformance with this Nodoer of Acceptance, the m8nufauturier's installation recommendations, and the applicable sections of the Florida -Sullding Code. Metal studs where HordlePariel, Cern panel, Prevail Panel Siding will be Installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A Note 11 W" thick 15 ply APA rated plywood sheathing shall be attached to metal studs at Woo at panel edges and all Intermediate supports using a No.6-18, 0.315" head diameter x 1-1/4" long bugle head screw The siding panels shall be installed over 518" thick / 5 ply APA rated plywood sheathing supported by a minimum 20ga, Nominal 3-5118"X 1-5/8" Metal C-studs spaced a mayjmum of is" O.C. Note 2] The siding panel fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-518" long* ribbed bugle head screw (or screw shall have at least 3 full threads penetrating.rnetal framing); the fasteners shall be spaced at 6" O-C. at panel edges and Intermediate studv, the fasteners shall be driven tbrough the 5/8" thick/ 5 ply APA rated plywood sheathing into metal studs located at 16" O.C. Fasteners shalt have a minimum edge distance of 3/8" and a minimum clearance of 2" from corners. Creator- E. Gonzales HARDIEPANEL, CEMPANEL, PREVAIL PANEL NSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 81ZE FSCM No DVr;. NO kEV A PNL-PLK-SOFF SCAL9 11TI 11-01. Date: 412412013 ISHEET 3 OP 12 6.001n. t I I I 6.001n. PRODUCT RENEWED as complying with the Florida Building Code 4OA-No. 17-0406-06 teO5/01/2022 6.010in. 3y . -A- viiaml e Product Control PRODUCTRE)ILSM 0 cmoyba VA& ft Flblift eh"me CAI& 7 Bmyi L, ,. T IZE Sr4J Wiyi,* with FIM4,k I - .. - EmKNQ NOMINAL 20 GAUGE X 1-5/8" STEEL STUDS IB" O.C. FASTENED WITH 5/8'WAFER HEAD SCREWS (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE 1H C! NOMINAL 518" THICK 15 PLY APA RATED PLYWOOD SHEATHING To METAL STUDS AT 6" OC AT PANEL EDGE$ AND ALL INTERMEDIATE SUPPORTS USING A NO,8-18,0.315" HEAD DIAMETER X I_jW LONG BUGLE HEAD SCREW g=&t NGQL __ THE PANEL IS FASTENED WITH NO. 8-18,0.315!'HEAD DIAMETER X 1-5/8' LONG CORROSION RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMINO), PLACE SCREWS 6" O.C. AT PANEL EDGES AND INTtERM5-DIATE STUDS 6,001n. Cladding raming Sheathing 141 1 t STATE ONA' FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) REV I WALL a WALL LENGTH ------------ - ------------------- SM at 16" O.C. 1) _:TPJ L A j 3/4" Minimum DLEIMUA KIN1,101A.M11 PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Distance Nails at- I$" Sheathing fastener, -as described in Note I Siding fastener, as described in Note 2 HardiePlank, ACemplank, Prevail I_ap Siding Water -resistive barrier per Florida Building Code Section 1404.P 518" thick 5 ply APA rated pplywoo slywoodsheathing fastened n a =rdance with Florida Building Code Section 2322.3 1 Expiration Mate05 01/2022 2"X 4" S-P-F Wood Studs The wall and soffit frames are to be designed 13Y #6 by the Architect or Engineer of Record InMlami-M I i)de Product Control compliance with the Florida Building Code. p RQDLLGI M qlk(RMLN Hardle?lankG, Cemplank(l, & PrevallO Plank Lap Siding materials 5/8" IN& 16 ply APA are nonasbestos fiber -cementtestedInaccordance withratedplywoodproducts ASTM C1186 Grade 11, Type A and sheathing in meeting the requirements of theaccordance %ith Florida Building Code. Florida Building Code Section 2322.3 PLA.NEL pjTAFNSIONS Width _. icknWater-roilstive Length es s barrierperFlorida 99-1/2' 12' 51161, Building Code Se ction 14042 211X4"S-P-F Installation Design Pressure Wood Studs Wood Studs -92 psf Lap Siding Impact Resistant - muno planks Installed over 5/8" thick / 5 ply0NA, ' If eC _\ 1 114"iall X 5/161, APA rated plywood sheathing thick starter striP N R A D on 0 a ce o Accep T 6 P 0 n I - j Soil L f Flo id BI e i for n with INonh rice, the manufacturersMintall ' nda Ins and he 8p Cable sect 0 9 the r aa01Inof n will be instisaw`h 0 a P X, 01 mpla Prevail Lap Sidl g t - mme tio Building Code. In t I I Ion re 0 0 od tud e H rdie la nstalled shall be designed by gin r or r h itet per th 0 1 laing Cod d th requirements of this KOAEngineecenM05eane Mate 11 518 , thi kj ply P t pj d s t I gs all attac eIc5AAmed00heahnhbehed to the studs in accordance with Florida Building Code Sertion 2322.3. 11 with 1-1W widePlanksshallbeappliedhorizontallycommencingfromthebottomcourseofthewa laps at the top of the plank such that the exposure area of each plank Is:5 8-`1MV'verhcaIIY, Note 2] The siding fastener shall be a 2-1/2' long, 0.223" head diameter, 0.092!' shank diameter, corroslon-resistant siding nail; The siding is ftistened e 8-114!, O.c. vertically arid I&, O.C. horizontally; fasteners are driven into wood studs through 5/8" thick / 5 ply APA rated plywood sheathing, fasteners are placed In the overlapping area approximately 3/4' from the bottom edge of the overlapping plank Vertical joints shall be placed over studs. The planks shall be installed over 5/8" thick/ 5 ply APA rated plywood sheathing Supported by a minimum of ZX4" S-P-F wood studs spaced a maximum of 16" O-C- Fasteners shall have a minimurn edge distance of 31d'. Creator. E. Gonzales HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION SIZE! FSCM NO A SOALE James Hardie Building Products, I nc. 10901 Elm Avenue Fontana, CA 92337 IMG No R EV PML-PI-K-SOFF I I Date; 412412013 ISHEFT 5 OP 12 Fastener Spacing per Florida Building Code Section 2S22.3 16 in. 0 Cladding PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 0.75in Expirailon DpteO5101/2022 By Miamj-Whai Pro -duct Control PROWCT REVLSM ns cmnoying witb the Fkxi& st6ldingCO& A,-,vt,nmi,io T BY Mimei ?adc Product MLNQ NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-112" 16d COMMON RAILS (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING NOMINAL 518" THICK / 5 PLY APA RATED PLYWOOD SHEATH ING* FASTEN 50 IN ACCORDANCE WITH FLORIDA BUILDING CODE SECTION 2322.3 9-&QDM- PLANKS,OVERLAP 1-114" THE EXPOSURE IS!58-1/4!' THE PLANKS ARE FACE NAILED WITH 2-11T LONG, 0.223" HEAD DIAMETER, 0.092" SHANK DtAMETER, CORROSION. RESISTANT SIDING NA)LS,-PLACED 3W UP FROM THE BOTTOM rzDGE OF THE PLANK AT EACH STUD LOCATIOIN Fastener Spac ig per Florida 8ullding Code Section 2322.3 MIMES Framing Sheathing 121 C("P4 lyw* with lbe Floritu 00-MiDS C4)ft No. STATE OF7 i nk Prodwil 0 c ORI FOR METAL AND WOOD STUDS, PRO\/1SIONS FOR DIAPHRAGM ACTnION LOAD ARE NOT PART OF TH[S APPROVAL (MUST PROVIDE ALtERNATE PROVISIONS FOR THESE LOADS) Phone: A HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc, 10901 Elm Avenue Fontana, CA 92:337 PNL-PLK-SOFF I i WALL Stud Spacing at 16" O 0. i --- ----- ------ IGHT Daft 41 0 6 IAT F nAiA;- 3/4' Minimum i- dge Distance Nails at %', U.C. (typ') QJI T& A Sheathing fastener, as described in Note I n 161.wWllyiN i vith UNA fky6ft Sidinn fastener as described in Not. HardiePlank, Cemplank, Prevail Lap Siding PRODUCT RENEWED as complying with the Florida 8.11ding Code NOA-No. 17-0406.06 Expiration By Water -resistive barrier per Florida Building Code section 1404.2 618" thick 15 ply APA rated plywood sheathing fastened to metal studs as described in. Note 1 05/01/2022 2Dgal 3-5/8"X 1-5/6' Metal C-StUd The wall and soffit frames are to be designed by the Architect or Engineer of Record Induct'd-o—ntrol complian Ice with the Florida Building Code. SEE DETAILA HardiePlankO, Cemplankg), and 8" thick 15 ply APA Prevaillii Plank [-qp Siding materials I rated pWood are nonasbestos fiber -cement sheathing Nstened products tested In accordance with to metal studs as ASTIM C1 186 Grade 11, Type A and described in Note I meeting the requirements of the Florida Building CQde. 111aler-resistive barrier per Florida PLAm4E_QL1qE N_S Bullding Code Width Length Thickness Section 1404.2 9-1/2' 12' 51161, DESIGN ERQ SIJ E RA DNPMeta; C-stud R --- Installation Design Pressure HardiePlank, k6r Metal Studs -92 psf C emplank, Prevail C 10 Lap Sldlng Impact Resistant - 1_1/4, tall X 5116" Planks Installed over 518" thick 15 ply thick starter strip APA rated plywood sheathing IAARRIEi&RK TLARK EPQk -,V&1L-LAUjQACLtRP!-A1, All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation recommendations, and the applicable sections of the Florida Building Code. Metal studs where HardlePiank, Cemplank, Prevall Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.0.& Note 115/8" thick / 5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oo at panel edges and all intermediate supports using a No.8-18, 0.31 O'head diameter x 1-1/4" long bugle head screw Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4' wide laps at the top of the plank such that the exposure area of each plank Is:5 8-114' vertically. INote 2) The siding fastener shall be a minimum No. 8-18, 0,316" head diameter X 2-1/4" ong* bugle head screw over metal studs (*or screw $halll have -at least 3 full threads penetrating metal framing); ne siding is fastened -- 8-1/4" O.C. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 5/8" thick / 5 ply APA rated plywood sheathing,'fasteners are placed in the overlapping area approximately 3/4* from the bottom edge ofthe overlapping planIc Vertical joints shall be placed over studs. The planks shall be Installed over 5/6'thick 15 ply APA rated plywood sheathing supported by a minimum 209a, Nominal 3-518" X 1-5/8" Metal C-studs spaced a maximum of 16' O.C. Fasteners shall have a minimum edge distance of 3/8". 6.00in. 6.00in. PRODUCT RENEWED as complying with the Florida Building Code 0.751n ;-- NOA-No. 17-0406.06 ------ f--Expiratio D te05/0112022 By Mlaml-EfWFT-oduct Control in "Wpplyilv WOO the Fhffid* E W-k%* CO& A.M.. r'.' Emma NOMINAL20 GAUGE3-5/B"X 1-5/8" STEELSTUDS 16" O.C. FASTENED WITH 5/8" LONG RIBBED BUGI F HEAD SCREWS (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE NOMINAL 518" THICK / 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 8" OC AT -PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A NO.8-18,0.315" HEAD DIAMETER X 1-1/4' LONG BUGLE HEAD SCREW jq-1m&Q-QW—Q PLANKS OVERLAP 1-114' THE EXPOSURE IS . 8-114" K THE PLANKS ARE FASTENED WITH NO, 6-18, 0.315" HEAD DIAMET15-R X 2-114" LONG CO RROSION- RESISTANT RIBBED BUGLE HEAD SCRI WS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING), PLACED 3/4!'UP FROM THE B01-rOM EDGE OF THE- PLANK AT EACH STUD LOCATION In. 6 00in.oc Cl8dding Framing 0, STATE OF 0 N' A Sheathing t FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISION8 FOR THESE LOADS) HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Produats,-Inc. 10901 Elm Avenue Fontana, CA 923:37 PSCM NO I DWG No Fax 909-427-0634 A PNL-PLK-SOFF Creator: E. Gonzales SCALE V M T-=T=Date: 4/24 =Zolas IEEEr 8 OF 12 WALL LENG- Stud Spacing at 16" 0_C_ WALL iEl HT L: 318" Minimum IXTALA PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Expiration DpjeO6/()1/2022 k- Nails at 4" O.0 Distance offlt fastener, as described in Note 1 HardleSoffit, Cemsoffit BYM11rr!11-0a06 Product Control Minimum 2" X 4" S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record In compliance With the Florida Building Code. SEE RRQQLn T-qEc91CRIFTLON. DETAILA HardieSoffit(D & Cemsoffi* rnaterialsare non2sbestos fiber -cement products tested in accordance with ASTM C1 186 Grade 11, Type A and meeting the requirements of the Florida Building Code. j_QJECLT PLIAEt4q P 2"X 4" S-P-F A,9 V'Jood Studs Width Length ThIcKness 4 . a 114, QF_r$ LQN_P_RM!_QjM_R&Tj_NA Hardie&ffi Installafion Design Pressure cemsoffit -Wood Studs -70 psf PP -)PRODUCT REVISW KZ0DUCrREVV;M MPIY* -ith the fjla to octuoying widA She Fla" CO& owding A40VUWow, No E5(plft" D ft 11Y mi Pradtwdt Cr*_"Q Al 21r-1, P4V t STATE OF p 0 R 3 N JAN-CLETAIL,$ All Installation shall be done In conformance With this Notice of Acceptance, the manufacturer's installation recommendations, and the -applicable sections of the Florida Building Code. Wood studs where HardleSoffit, Cernsoffit will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. The soffit shall be installed over minimum 2!X4PS-P-F w000 studs spaced a maximum of 16" O.C. Note 11 The soffit fastener shall be a 2" long, 0.223" head diameter, 0.092" shank diameter, corrosion resistant siding nail; the fasteners shall be spaced at 4!'O.G. at panel edges and intermediate studs.; the Msteners; shall be driven into wood studs located at 16" Ot. Fasteners shall have a Minimum edge distance of 3/8" and a minimum clearance of 2" froni corners. HARDIESOFFIT, CEIVISOFFIT PANEL INSTALLATIO N DETAI LS WOO D STU D CO NSTRUCTION James Hardle Building Products, Inc- 10001 Ulm Avenue Fontana, CA 92337 Phone: 909-356-6300 SIZE FSCII Nc Mu NO Fax 909-427-06 4 A PNL-PLK-SOFF Creator: E. Gonzales SCALE 1/2" - 1.41 Date: 4124/2013 1 SHEET 9OF12 Cladding rraming PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Expiration DaleOS101/2022 By 4,00i Miami-1360-Product Control PRObUL-C REVI S ED ollyff PRC)DUCTRE MM if 0 "WoYibg With 116C FWAA awl" Co& - M-pl itq -ith 6ft Florida Btilding cw: - A=emm)-m 7 N 0. 0. STATE Of k 4!7 F RA M LN-Q NOMINAL 2" X 4!'S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARECONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE THE SOFFIT 18 FASTENED WITH 2- LONG, 0.223" HEAD HARDIESOFFIT, CEMSOFFIT PANEL DIAMETER, 0.092" SHANK DIAMETER, CORROSION INSTALLATION DETAILS WOOD STUD CONSTRUCTION RESISTANT SIDING NAILS, PLACE NAILS 4!'O.C. AT PANEL EOGES AND INTERMEDIATE STUDS James Hardie Building Products, Itio. 10901 Elm Avenue Fontana, CA,32337 Phone: 909-356-630Q S111 FSCMN0 DWG NO RFV Fax 909-427-0634 A PNL-PLK-SOFF Creator: E, Gonzales ISCAL2 V= 1'O" TDafe: 4124/2013 1 sHECT 100F.12 T V ALL HEIG fl I , WAL.1- LENGTH SEE Stud Spacing -at 16" D.C. D ETAI L A HardieSoffi* & Cemsoffi* materials FA *--- I I are nonasbestos fiber -cement products B QI]Tj kl L-A tested In accordance with, 'S Grade 11, TypeA and meel 'IMn7------ -- — ---------- requirements of the Florida Building PRODUCT RENEWED Code. I as complying with the Florida Building Code 20ga, 3-5/8"X 1-5t8" NOA-No. 17-0406.06 Metal C-stud Width Length Thickness 05/01/2022Expiratio HardieSoffit, v' Cen=tfit Miami-Dzfdo-Vr—oduct Eo—ntrol Installation Design Pressure Nails at 6" O.C- (typ.) 318" Minimum Edge Distance fastener, as ribed in Note I HardieSoffit, Cemsoffit 20ga, 3-518" 1 -6/8" Metal C-stud LThe wall and soffit frames are to be designed by the Architect or Engineer of Record In compliance with the Florida Building Code.. Metal Studs -55 gf MODUCT RLVLSVL# S coovlyipa VAW trA FIMOR FA ccowpy* with Eke F%" 13ijilding Coft amldft Q* 12 xwoftm No Z STATE ()F 0 All installation shall be done in conformance with this Notice of Accept YM6*acturers installation reciommendatlons, and the -applicable sections of the Florlds Buliding Code. Metal studs where HardleSoffit, Cemsoffit will be installed shall be designed by an Engineer or Architect per the Florida 13ulldIng Code and the requirements of this N.O.Al* The soffit shall be installed over minimum 20ga, NomInal 3-518" X 1-5/8" Metal C-studs spaced a maximum of,16!'O.C. Note 1] The soffit fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-1/4* fong* ribbed bugle head screw ("or screw shall have at least 3 full threads penetrating metal framing);the fasteners shall be spaced at 6" D.C. at panel edges and Intermediate studs; the fasteners shall be driven Into metal studs located at 16" O.C. Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of Z'from comers. HARDIESOFFIT, CEIVISOFFIT PANEL INSTALLATION DETAILS METALSTUD CONSTRUCTION James Hardie Building Produc;ts, Inc. 0 10901 F-Im Avenue1WFontana, CA 92337 Ihone: 909-356-6300 SIZE FX11 NO OMNO REV Fax 909-A27-06-34 PNL-PLI<-SOFF Creator-, E.. Gonzales SCALE' 112 - v-0,- Date! 412412013 1 SHERT 12 6,001n. Cladding Framing 6.001n. PRODUCT RENEWED pRtMCrREV1SE0 so conoyirq with the VZOM4 -PR("'%CTttL-NbW as comp ing with the Florida ftkung C-4e "'OyVg wieb ft fwri& Building "lode Awe ptarm 17-0406.06 ')711 AwNOA-No. -07 1011 7 Expiration 05/01/2022 By By PrO&VtComm, Miami-DA Product Controldf Z Ss 0 g NOMINAL 20 (3.AUGIE 3-518t'X 1-518" STEEL STUDS 1611 O.C. FASTENED WITH 6/5"WAFER HEAD SCREWS (2 PER TOP FOR METAL AND WOOD S7UDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE AND BOTTOM CONNECTION) - NOT PART OF THIS APPROVAL (MUST PROVIDIE ALTERNATE PROVISIONS FOR THESE LOADS) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CLADDING HARDIESOFFIT, CEIVISOFFIT PANEL IS FASTENED WITH NO. 8-16,0.315" HEAD INSTALLATION DETAILS METAL -STUD CONSTRUCTIONDIAMETERX1-114' LONG CORROSION RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENE ' TRATING THE METAL FRAMING), PLACE James Hardie Building Products, Inc. SCREWS 6'O.C. AT PANEL EDGES AND INTERMEDIATE 10961 P-Im Avenue STUDS Fontana, CA 92337 Phone: 909-356-6300 SIM —MNO DWO No REV Fw< 909-427-0634 A PNL-PLK-SOFF ITDalSHE5T12. Or 12Cre8tor: E, Gonzales SCALE Date: V2412013 PROJECT RIO-2689-17 ENGINEERING EVALUATION REPORT FOR ATTACHING JAMES HARDIE@ BRAND FIBER -CEMENT PANELS TO WOOD FURRING SOLUTIONS JAMES HARDIE BUILDING PRODUCTS, INC. 10901 ELM AVENUE FONTANA, CA 92337 TABLE OF CONTENTS COVER PAGE EVALUATION SUBJECT EVALUATION SCOPE EVALUATION PURPOSE REFERENCE REPORTS TEST RESULTS TABLE 1A, RESULTS OF TRANSVERSE LOAD TESTING TABLE I B, ANALYSIS OF ALLOWABLE LOAD FOR #8 SCREW AT 10" O.C. JUSTIFICATION OF USING THE RESULTS ON LIGHT GAUGE STEEL FRAMING DESIGN WIND LOAD PROCEDURES TABLE 2, COEFFICIENTS AND CONSTANTS USED IN DETERMINING V AND p TABLE 3, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE B TABLE 4, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE C TABLE 5, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE D TABLE 6, ALLOWABLE WIND SPEED (MPH) FOR HARDIEPANEL SIDING PAGE 1 2 2 2 2 2 2 2 2 3 4 4 4 4 5-6 AS PRODUCT EVALUATOR, THE UNDERSIGNED CERTIFIES THAT THE LISTED PRODUCTS ARE IN COMPLIANCE NTH THE REQUIREMENTS OF THE ASCE 7-10, THE 2017 FLORIDA BUILDING CODE, AND THE 2015 INTERNATIONAL BUILDING CODE. PREPARED BY: RONALD 1. OGAWA & ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX FLO? a RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 M 714-292-2602; (F) 714-847-4595 PROJECT: RIO-2689-17 EVALUATION SUBJECT HardiePaneIV Siding James Hardie Product Trade Names covered in this evaluation: HardiePane]O Siding, CempaneI8 Siding. Prevail- Panel Siding EVALUATION SCOPE: ASCE 7-10 2017 Florida Building Code 2015 International Building Code 2015 International Residential Code JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com EVALUATION PURPOSE: This analysis is to determine the ma)dmunn design 3-second gust wind speed to be resisted by an assembly of HardiePanel (Cempanel, Prevail Panel) siding fastened to wood furringS on eitherwood or metal framing with nails or screws. REFERENCE REPORTS: 1. Intertek Report 102024363COO-001A, Transverse load test on HardiePanel. TEST RESULTS: Table la. Results of Transverse Load Testing Frame Fastener Ultimate Allowable Test Thickness Wdth Spacing Spacing Fastener Type Load Design Load2 Report Number Agency in.) in.) Frame Type' in.) in-) and Dimensions PSF) PSF) Failure Mode 102024363CDQ-ODIA Intertak 0.3125 48 2X4 wood stud, 3/4" thick by 16 6 No. 8 X 1.25' long X 0.323"HD 160.7 53.6 pull through /fracture3.5' wide SPF furring ribbed bugle head screws 102024363COO-001A Intertek 0.3125 48 2X4 wood stud. 314" thick by 16 8 No. 8 X 1.25' long X 0.323'HD 131.4 through3.5" wide SPF furring r1bbed bugle head screws - 43.8. pull 102024363COQ 001A In tertek 0.3125 48 2X4 wood stud. 314" thick by 16 12 No. 8 X 1.25'long X 0.323'HD 106.1 35.4 pull through I 1 1 3.5' wide SPF furring ribbed bugle head screws 102024363COQ-001A Intertek 0.3125 48 2X4 wood stud, 3/4" thick by 16 6 0.090' shank X 0.215" HO x 1.5' 147.6 49-2 pull through /fracture3.5' wide SPF furring long ring shank nail 102024363COO-001A Interlek 0.3125 48 2X4 wood stud, 3/4" thick by 24 8 No. 8 X 1.25' long X 0.323' HD 82.7 27.6 pull through /fracture3.5'wide SPF furring ribbed bugle head screws 1 - Ail 1-iti- - u iri5i ied an furring wrihout penetration into the framing members. 2. Allowable load is determined from ultimate load divided by a factor of safety of 3. 3. HardiePanel Siding complies with ASTM C1 186, Standard Specification for Grade It, Type A Non -asbestos Fiber -Cement Flat Sheets - Table 1 b. Analysis of Allowable Load for #8 Screw at 10" O.C. 8 Screw Spacing Fastener Spacing (in. 8 12 10 Frame spacing (in.) 16 16 16 Fastener Tributary area (ft) 0.89 1.33 1.11IAllowableload (psf) 43.8 35.4 38.8 Individual fastener load (lb.) 38.9 A79 Aq 1 The fastener load for #8 screw at 10" D.C. was calculated as the average of the test results for 8" and 12" D.C. The allowable load for #8 screw at the spacing of 10" D.C. into furring can be calculated by interpolating the results of same fastener at ir and 12" D.C., since both tests had same failure mode of fastener pull through from the panels. As shown in the table, the allowable load for #8 screws installed at 10" D.C. to wood furring is 38.8 psf. Justification of Using the Results on Light Gauge Steel Framing In the subject configurations, all fasteners were attached to furring only, so whether the furring is attached to wood or steel framing does not affect panels' transverse load capacity. It's the project engineer's responsibility to ensure the furring attachment and framing memebers to have sufficient load capacities- 110 0 cjGAWA se wc__ms`* Z,0% RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 T) 714-292-2602; (F) 714-847-4595 PROJECT: RIO-2689-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com DESIGN WIND LOAD PROCEDURES: Fiber -cement siding transverse load capacity (wind load capacity) is deten-ninedvia compliance testing to transverse load national test standards. Via the transverse load testing an allowable design load is determined based on a factor of safety of 3 applied to the ultimate test load. Equation 1, c6=0.00256*K,*K,*K,-V' fref ASCE 7-10 equation 30.3-1) q, velocity pressure at height z K, velocity pressure exposure coefficient evaluated at height z K,, topographic factor Equation 2, Kd wind directionallty, factor V basic wind speed (3-second gust MPH) as determined from 2015 IBC Figures 1609.3(11), (2), or (3); ASCE 7-10 Figures 26.5-1A, 8, or C V=V, fref 2015 IBC Section 1602.1 definitions) V,,,, . ultimate design wind speeds (3-second gust MPH) determined from 2015 IBC Figures 1609-3(l), (2), or (3); ASCE 7-10 Figures 26.5-1A, B. or C Equation 3, p=q'(GC,-GCpj) (ref ASCE 7-10 equation 30.6-1) GCp product of external pressure coefficient and gust -effect factor GCPj product of internal pressure coefficient and gust -effect factor I p design pressure (PSF) for siding (allowable desgn load for siding) To determine design pressure, substitute q, into Equation 3, Equation 4, p=0.00256-K,-K,-V 2'(GC,-GCpiI Allowable Stress Design, ASCE 7-10 Section 2.4. 1, load combination 7 E4uatlon 5, 0.6D - 0.6w fref. ASCE 7-10 section 2.4. 1, load combination 7) D dead load W wind load To determine the Allowable Stress Design Pressure, apply the load factor for W (wind) from Equation 4 to p (design pressure) determined from equation 4 Equation 6, p- = 0.6*[pj Equation 7, P— = 0.6*10.00255-K,-K-Kd'V'-(GCp-GC,)I Equation 7 is used to populate Table 3, 4, and 5. To determine the allowable ultimate basic wind speed for Hardie Siding in Table 6, solve Equation 7 for V., Equation 8, Vi,, = (p,/0-6*0-00256*K*K*K,*(GC,-GC,,))" Applicable to methods spedfied in Exceptions I through 3 of 2015 IBC Section 1609. 1. 1., to determine the allowable nominal design wind speed (Vasdl forHardie Siding in Table 6, apply the conversion Formula below, Equation 9, V. = V. fref. 2015 IBC Section 1609.3.1) V_ Nominal design wind speed (3-second gust mph) fref 2015 IBC Section 1602. 1) RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 T) 714-292-2602; (F) 714-847-4595 PROJECT: RIO-2689-17 Table Z Coefficients and Constants used in Determining V and p, K WaH Zme 5 Height (ft) Exp B Exp C Exp D K. K,, GC, GCj 0-15 0.7 0.85 1.03 h!;60 1 0.85 1.4 0.18 20 0.7 59 T- 58 1 0.85 1.4 0.18 25 0.7 0.94 1.12 1 0.85 1.4 0.18 30 0.7 0.98 76 1 0.85 1.4 0.18 35 0.73 1.01 7-19 1 1.4 0.18 40 1 0.76 1.04 1 0.8-5- 0.85 1.4 0. 45 0.7B5 1.065 1.22 4 1 0.85 1.4 0.18 50 0.81 1.09 1.27 1 8' 0.18 55 0.83 111 1.29 1 9N 1 tl 0.1. 60 0.85 1.13 1.31 1 0.85 1.4 0.18 100 0.99 1-26 1.43 1 h 60 1 0.85 1.8 078 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com Table 3, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category B, nd Speed (3-second gust) 100 105 110 1 L5 __ 120 130 140 150 160 170 180 190 200 210 Height (ft) B a B a B B B a B B B B B 0-15 14.4 15.9 17-5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 20 14.4 15.9 17.5 19.1 20-8 24.4 28.3 3Z5 37.0 41.7 46.8-- 52A 57.8 63.7 25 14.4 159 17.6 191 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 30 14.4 15.9 17.5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 45.8 52.1 57.8 63.7 35 15.1 15.6 18.2 19.9 21.7 25.4 29.5 33.9 38.6 43.5 48.8 54.4 60.2 66.4 40 15.Z 17-3 19.0 207 22.6 26.5 30.7 35.3 40.1 45.3 50.8 56.6 62.7 69.1 45 16.2 7.9 19.6 21.4 23.3 27.4 31 77 3 41-1 415.1]1 12.5 58.5 64.8 71.4 50 117.1 16.7 18.4 20.2 22.1 24.1 28.2 42.8 48 - 3 54.1 60.3 66.8 73.7 55 18.9 20.7 22.6 24.7 28.9 33.6 38.5 43.8 495 55.5 61.8 68.5 75.5 60 TITT- 1§'.3 21.2 23.2 25.2 29.6 34.4 39i5 494 9 5 .7 756 -B 7 5-3- 1 77.3 100 25.6 28.2 1 31.0 33.8 36.9 43.3 5 0.2 1 F 65.5, - 7440 82.9, 92.4 102.4 g1129 Table 4, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category C, nd Speed (3-second gust) 100 105 110 115 120 130 140 150 160 170 180 190 200 210 Height (ft) C C C C C C C C C C G C C C 0-15 17.5 19.3 21.2 23.2 25.2 29.6 34.4 39.5 44.9 50.7 56.8 63.3 70.1 77.3 20 18.6 20.5 22.5 24.6 26.7 31-4 36.4 41.8 47.5 637 60.2 67.0 74.3 81.9 25 19.4 21.4 23.5 25.6 27.9 32-8 38.0 43.6 49.6 56.0 62. - 8 70.0 77.6 85.5 30 20.2 22.3 24.5 26.7 29.1 342 39.6 455 51 8 56.4 65.5 73.0 80.9 89.2 35 20.8 23.0 25.2 27.6 30.0 35.2 40.8 46.9 53.3 602 57.5 75-2 83.3 91.9 40 21.5 23.7 26.0 28.4 30.9 36.3 42.0 48.3 54.9 62.0 69.5 77.4 85.8 94.6 45 22-0 24.2 26.6 2 50 22.5 248 272 29.7 324 38.0 44,1 50.6 57.6 65.0 72-9 81.2 89.9 99.2 55 22.9 25.2 27.7 30.3 33. 38.7 44.9 51.5 58.6 66.2 74.2 91.6 101.- 60 23.3 25.7 28.2 30.8 33.6 39.4 45.7 5-2.4 59.7 67.4 23 75.5 84.1 93.2 102.8 100 32.6jig 35.9 39.4 43.1 46.9 55.0 63.8 . 73.3 B3.4 94.1 105.5 6 130.3 143.6_ Table 6, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category D, nd SDeed (3-second gust) 100 105 110 115 120 130 140 150 1 160 170 180 i90 200 210 Height (ft) D D D 0 D D D D D D D D D 0-15 21.2 23.4 25.7 28.1 30.6 35.9 41.6 47.8 54.4 61.4 68.8 76.7 85.0 93.7 20 22.3 246 27.0 29.5 32.1 37.7 43.7 50.1 57.0 64.4 72.2 80.4 89.1 98.2 25 23.1 25.5 28.0 30 6 33.3 39.0 45.3 52.0 59.1 668 74.9 83.4 92.4 101.9 30 23.9 25.4 29.0 31.6 34.5 40.4 46.9 53.8 61.3 69.2 77.5 86.4 95.7 105,5 35 24 5 27.1 29.7 325 35.3 41.5 48.1 55.2 62.8 70.9 79.5 88.6 98.2 108.3 40 25.2 27.7 30.5 33.3 36.2 42.5 49.3 566 64.4 72.7 81.5 90.9 100.7 111.0 45 25.7 28.3 31.1 34.0 37.0 43.4 50.3 57.8 65.7 74.2 83.2 927 102.7 113.3 50 26.2 28.9 31.7 34.6 37.7 44.3 51.3 58.9 67.1 75-.7 84.9 94.6 104.8 115.5 55 26.6 29.3 32.2 7 35.2 35-7- 38.3 38.9- 45.0 52.2 59. 8 .1 76.9 86.2 116F 1 os. 117.4 60 27.0 29.8 Z2 45.7 53.0 60.9 19.2 7-8.1 87.6 11.6 108.1 119.2 100 37.0 40.8 44.7 48.9 53.2 62.5 72.6 7706-8 119.8 1 -133.4 1479 1630 Tables 3, 4, and 5 are based -on ASCE 7-10 and consistent with the 2015 IBC, 2015 IRC A WA 9\1p, t 1 ' 4'vtf 11-""' X 1 /"i ' 0 0 RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 T) 714-292-2602: (F) 714-B47-4595 PROJECT: RIO-2689-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-885-542-7343 info@jameshardie.com Table 6, Allowable Wind Speed (mph) for HardiePanel Siding (Analytical Method in ASCE 7-10 Chapter3O C&C Part I andPart 3)' 2015 ISC, 2017 FBC 2015 IBC, 2017 FBC Allowable, Ultimate Allowable, Nominal Design Wind, Speed, Design Wind, Speed, V'..5' V_4.5' 3-second gust mph) 3-secand gust mph) Applicable to methods specified in 12015 IBC, Appllcabie to methods 2017 Faq Section specified in Exceptions I 16091A. as detemined by through 3 of 12015 IBC, 12015 IBC, 2017 FBCJ 2017 FBq Section Mg.- 1609.3(1), (2), 1609.1.1. 3). Coefficients, -ad in Table 6 calculations for V., VIAnd exposure category Wind"exposure category Siding Product Minimum Thickness in.) V%Adth in.) Fastener Type Fastener Spacing in.) Frame Type Stud Spacing in.) Building Height2.5 ft.) B C D a C D Alto abl. Design Load PsO Exp S Exp C Exp 0 K. K. GC, GC, 0-15 193 175 159 149 135 123 53.6 0.70 0.85 h,60 0 85 14 018 20 193 170 155 149 132 120 53.6 0.70 0.90 1.03 1.08 j_ 1 0.85 1.4 0.18 HardiePaneM 5116 48 No. 8 X 1.25* long X 0.323" HD ribbed bugle head 6" O.C. into furring only 2X4 wood or 20 ga. steel framing, 3/4' thick by 3.5" wide wood 16 25 193 166 152 149 129 118 53.6 0.70 0,94 1.12 1 1 C.B5 1.4 0.18 30 193 163 150 1 149 126 116 1 -536 0.70 0.98 1.16 L 1 0.85 o0.85 1.4 1.4 0.181 0.1835189160114814612411453.6 0.73 1.01 1 1.19 40 185 158 146 143 122 113 53.6 0.76 1.04 1. 2 1 0.85 1,4 0.18 45 172 150 140 133 116 108 53.6 0.88 1.15 I L 085 14 18 screws furring 50 179 154 143 139 120 111 53.6 0.81 1.09 127 1 OZ51 1.4 0.18 55 177 153 142 137 119 110 53.6 0.83 1,11 1.29 1 M0.85 1.4 0.18 60 IZ 152 141 135 117 log 53.6 o.85 1.13 1.31 1 0.85 1.4 TI-8 oo 514, 128 120 112 99 93 536 0,99 126 143 h>60 0.85 1.8 0.1811 0-15 174 158 144 135 122 1 Ill 1 -43.8 0.70 0.85 1.03 h 60 1 0.85 1.4 018 20 174 154 140 135 119 1 109 1 -43.8 0.70 0.90 1.08 1 0.85 1.4 018 HardiePanelO 5116 48 No- 8 X 1.25'iong X 0.323' HD ribbed bugle head screws 8"O.C. into furring only 2X4 wood or 20 ga. steel framing, 3/4" thick by 3.5' wide wood furring 1.7.8 16 25 174 150 138 1 135 116 107 1 -43.8 0-70 0.94 1.12 1 85 1.4 0.18 30 174 147 135 135 114 105 43.8 0.70 0.98 1.16. 1855 1.4 0.18 35 171 145 134 132 112 103 43.8 173 1.01 1.19 L 1 0.85 1.4 0-18 40 167 143 132 129 ill 102 43.8 0.76 l.D4 1.22 1 0.85 1.4 0.18 45 164 141 131 127 109 101 43.8 0.79 1.07 L.25 0.115 1.4 0.18 50 162 140 129 125 108 100 43.8 0.81 1.09 1.27 L 1 21' 1.1 718 15 12 138 128 124 107 99 43.8 783 1.11 1.29 1 l 11 14 0.181 8 137 127 M 106 99 43.8 7-aT 1.13 1.31 1.4 0.18 100 131 116 101 90 43.8 0.99 126 1. 3 h,60 1 0.1551 1.810.18 0-15 164 149 135 127 115 105 38.8 0.70 0.85 1.03 hs60 1 0.851-1.410.18 20 164 145 132 127 1 1 2 102 0.70 0,90 1.08 1 0.85 1.4 0.18 HardiePanelS 5/16 48 No. 8 X 1.25"long X 0-323" HD ribbed bugle head screws 10"O.C, into furring only 2X4 wood or 20 ga. steel framing, 3/4' thick by 3.5' wide wood furring "7" 16 25 164 141 130 127 110 loo W.8 38.8 0.70 0-9L 1.12 1 0.115 1.4 D.18 30 164 139 127 127 107 99 38.8 0.70 1 0.98 1.16 1 0.65 1.4 0.18 35 161 136 126 124 106 97 38.8 0-73 1-01 1.19 1 0-85 1.4 71-8 40 157 134 124 122 1D4 96 38.8 0,76 1 04 1.22 1 0.85 1.4 0.18 45 155 133 123 120 103 95 38.8 O 79 1.07 1.25 085 14 018 50 152 131 122 IIB 102 - 94 38.8 0.81 1 09 1.27 L 1 0.85 1.4 U-18 55 151 13 121 117 101 94 38.8 O.a3 1.11 1.29 1 0 B5 1 4 0.18 129 120 115 100 93 38.8 0.85 1.13 1. 1 1 115t-4 17 100 123 95 M38*8 0.99 1.26 1.43 h>60 1 0.85 1.8 0.18 0-15 157 142 129 121 110 100 35.4 0.70 0.85 1.03 hs6O 1 0.85 1-4 0.18 2G 157 138 126 121 107 98 35.4 0.70 0.90 1 08 1 0.85 1.4 0.18 HardiePanel& 5116 48 No. 8 X 1.25"iong X 0.323" HD ribbed bugle head screws 12"O.C. into furring only 2X4 wood or 20 ga. steel framing, 3/4* thick by 3.5' widewood furring 16 25 157 135 124 121 105 96 35.4 0.70 0.94 1.12 085 14 118 30 157 132 122 121 103 94 35.4 0,70 0.98 1.16 L 1 O.B5 1.4 0.18 35 153 130 1 12 1 119 101 93 35.4 0.73 1.01 1AL 1 0.85 1.4 0.18 40 150 228 119 1 116 100 92 35.4- 0.76 1.04 1,22 1 0.85 1.4 0.18 45 148 127 117 115 98 1 35.4 0,79 1 '07 1 '25 1 0.115 1.4 0.18 50 146d44 125 116 113 97 0 35.4 081 1.09 1 71.27 1 0.85 1.4 0.18 55 1 124 115 ill 96 89 35 4 7- E-B3 1. 1 !1 1.29F 1 0.85 1.4 0.18 60 142 123 1141110 95 89 35A 0.85 I ':' 1 0.18 118 il91 0.18 N A LU4j, FLO es S 10 RONALD 1. OGAWA ASSOCIATES, INC. 16635 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 M 714-292-2602; (F) 714-847-4595 PROJECT: RIO-2689-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com Alowable, Ultimate Allowable, Nominal Design Wrid, Speed, Design Wind, Speed, V'3. vi,.'- 3-second gust mph) 3-second gust mph) Applicable to methods specified in [2015 IBC, Applicable to methods 2017 FBC] Section specified in Exceptions I 1609.1.1.asdelerminedby thmugh3of[20151BC, 12015 IBC, 2017 FBq 2017 FBq Section Figures 1609.3(l), (2), or 1609.1.1. 3). Coefficients used in Table 6 calculations for Vm VAnd exposure category VIAnd exposure category Siding K Product Minimum Thickness in.) Width in.) Fast ner Type Fastener Spacing in.) Frame Type Stud Spacing in.) Building Height A) 1 1 1 1 4jjowble Design Load PsO Exp 8 Exp C Exp D i K, r. GC, GC G-1 5 138 125 114 107 97 88 27.6 0.70 0.85 1.03 hcW 0.85 1.4 0.1 B 20 136 122 111 107 94 86 27.6 0.70 0.90 1.08 L 1 0,85 1.4 0.18 25 138 119 107 92 27.6 0.70 0.94 1 0.85 1.4 0.18 HardiePanelS 5/16 48 No. 8 X 1-25"long X 0 323" HD n . bbed bugle head screws 8" D.C. into furring only 2X4 wood or 20 ga- steel framing, 314* thick by 3.5- wide wood furring 24 30 138 117 107 91 27.6 0.70 0.98 1-12] 1.16 1 0,85 1.4 0.18 35 135 115 105 9898 27.6 073 101 1.1 1 0X5 1.4 0.18 40 133 113 103 S888 27.6 0. 6 D4 1. 1 0.85 1,4 0.18 45 131 112 101 8 787 27.6 0.79 1.07 1 1 0.85 1.4 0.18 50 1209 ill 100 86 27-6 0.81 1.09 1.27 1 085 14 0.18 55 127 98 27.6 OZ3 1.11 1.29- 1 0-85 1.4 0.18 60 125 97 27.6 0.85 1.13 1.31 1 085 1.4 0.18 100 P121 27.6 0-99 1.26 1.43 ln 60 1 0.85 1.8 0.18 0-15 185 168 152 143 130 118 49 2 0.70 0.85 1.03 h 60 1 0.85 1.4 0.18 20 185 163 149 143 125 115 49 2 0.70 OM 1M 1 0.55 1.4 0.18 25 185 159 146 143 123 113 4 .2 0.70 0.94 112 HardiePanel& 5116 48 0.090, shank X 0 215' HD X" 1.5'long ring shank nail 6" ().C. into furring only 2X4 Wood or 20 ga. steel framing, 3/4' thick by 3.5* wide wood furring 1"" 16 1 S0.85 1.414 18018 30 185 156 143 143 Ill 492 0.70 098 1.16 1 081 1.4 0.18 35 181 154 142 140 1 9119 110 49 2 0.73 1.01 1.19 1 0.85 1.4 0.18 40 177 151 140 137 117 108 492 7 76 1.D4 7- 22 1 085 1-4 l) ' 0.18 45 174 150 138 135 116 107 49.2 0.79 107 1.25 1 011.5 1.4 O' 0.18 50 172 148 137 133 115 106 49.2 0.81 1.09 7 1 i0.85 1.4 0.18 55 170 147 136 131 114 105 49.2 0.83 1.11 1-29 0 85 1-4 0.18 60 168 145 135 130 113 105 4 .2 0.85 pl,2 61 0.85 1.4 0. L8_ 100 139 123 115 107 95 89 49.2 1 0.99 1.43 h 60 1 1 0.851 1.81 0.18 i. t- umng ana crimern io structurai traming members or afternative turring wdtn snail de oesigned by an en gin.. r- 2. Building height = mean mot height (in feet) of a building, except that eave height shall be used for roof angle E) less than or equal to 100 (2-12 roof slope). 3. V = ultimate design wind speed. 4. V, = nominal design Wnd speed S. Linear interpolation of building height ( 60 it) and wind speed is permitted. 6. Wind speed design assumptions per Analytical Method in ASCE 7-10 Chapter 30 C&C Part I and Part 3: K ,=1, K,=0.85, GC,1.4 (h550), GC,1.8 (h,60), GC,--O.l 8. 7- Wood furring shalt be preservative treated per AWPA. 8. Wood furring shall be specific gravity of 042 or greater per AFPAINDS; or wood structural panel, confor-ning to DOC PS-1 or DOC PS-2 or APA PRP-1 08. LIMITATIONS OF USE: 1) In High Velocity Hurricane Zones (HVHZ) install per Miami -Dade County Florida, NOA 17-0406.06 PROJECT RIO-2686-17 ENGINEERING EVALUATION REPORT FOR ATTACHING JAMES HARDIE@ BRAND FIBER -CEMENT PANELS TO WOOD AND METAL FRAMED WALLS WITH VARIOUS FASTENERS JAMES HARDIE BUILDING PRODUCTS, INC. 10901 ELM AVENUE FONTANA, CA 92337 TABLE OF CONTENTS PAGE COVER PAGE 1 EVALUATION SUBJECT 2 EVALUATION SCOPE 2 EVALUATION PURPOSE 2 REFERENCE REPORTS 2 TEST RESULTS 3 TABLE 1A, RESULTS OF TRANSVERSE LOAD TESTING 3 TABLE 1 B, SHEAR VALUES 3 DESIGN WIND LOAD PROCEDURES 4 TABLE 2, COEFFICIENTS AND CONSTANTS USED IN DETERMINING V AND p 4 TABLE 3, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE B 5 TABLE 4, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE C 5 TABLE 5, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE D 5 TABLE 6, ALLOWABLE WIND SPEED (MPH) FOR HARDIEPANEL SIDING 6-7 LIMITATIONS OF USE 7 AS PRODUCT EVALUATOR, THE UNDERSIGNED CERTIFIES THAT THE LISTED PRODUCTS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE ASCE 7-10, THE 2017 FLORIDA BUILDING CODE, AND THE 2015 INTERNATIONAL BUILDING CODE. PREPARED BY: RONALD 1. OGAWA &ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX 111 1 1 If 101 RONALD 1. OGAWA ASSOCIATES, INC- 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com EVALUATION SUBJECT HardiePanel@ Siding James Hardie Product Trade Names covered in this evaluation: HardiePanel& Siding, Cempanel& Siding, Prevail- Panel Siding EVALUATION SCOPE: ASCE 7-10 2017 Florida Building Code 2015 International Building CodeO EVALUATION PURPOSE: This analysis is to determine the maximum design 3-second gust wind speed to be resisted by an assembly of HardiePanel (Cempanel, Prevail Panel) siding fastened to wood or metal framing with nails or screws. REFERENCE REPORTS: 1. Intertek Report 3067913 (ASTM C1 186) Material properties HardiePanel Siding 2. Ramtech Laboratories Report [C-127D-94 (ASTM E330) Transverse Load Test, 5116"Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 16 inches on center with a 6d common galvanized nail 3. Ramtech Laboratories Report IC-1 271-94 (ASTM E330) Transverse Load Test. 5/16" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 24 inches on center with a 6d common galvanized nail 4. Ramtech Laboratories, Inc. Report 10868-97/1475 (ASTM E330) Transverse Load Test, 5116" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Group III SG=0.36 Wood studs spaced at 16 inches an center with a 4d, 0.091 inch shank by 0.225 inch head diameter by 1.5 inch long ring shank nail 5. Ramtech Laboratories, Report IC-1 054-89 (ASTM E330) Transverse Load Test, 1/4" Thick by 48 inch wide HardiePanel Siding installed on 20gauge Metal studs spaced at 16 inches on center with a No 8 X I in. long X 0.323 in head diameter ribbed bugle head screw 6. Ramtech Laboratories, Report IG-1055-89 (ASTM E330) Transverse Load Test 114" Thick by 48 inch wide HardiePanel Siding installed on 20gauge Metal studs spaced at 24 inches on center with a No 8 X I in. long X 0.323 in head diameter ribbed bugle head screw 7. Ramtech Laboratories, Report I I 149-98/1554d (ASTM E330) Transverse Load Test, 1/4" Thick by 48 inch wide HardiePanel Siding installed on 20gauge Metal studs spaced at 16 and 24 inches on center with a ET&F 0. 100 in. knurled shank X 1.5 in. long X 0.25 in. head diameter pin fastener 8. Ramtech Laboratories Report IC-1 273-94 (ASTM E72) Racking Shear Test, 5/16" Thick by 48 inch wide HardiePanel Siding instalied'an 2X4 Hem -Fir wood studs spaced at 16 inches on center with a 6d common galvanized nail 9. Ramtech Laboratories Report IC-1 274-94 (ASTM E72) Racking Shear Test, 5116" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 24 inches on cerrierwith a 6d common galvanized nail 10. Ramtech Laboratories, Inc. Report 10868-9711475 (ASTM E72) Racking Shear Test, 5/16" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Group III SG=0.36 wood studs spaced at 16 inches an center with a 4d, 0.091 inch shank by 0.225 inch head diameter by 1.5 inch long ring shank nail 11. Ramtech Laboratories Report IC-1057-89 (ASTM E72) Racking Shear Test, 5/16" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem-Firwood studs spaced at 16 and 24 inches on center with a No 8 X 1 in. long X 0.323 in head diameter ribbed bugle head screw 12. Ramtech Laboratories Report 11284-99/1580 (ASTM E72) Racking Shear Test, 5116" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hern-FirwDod studs spaced at 16 and 24 inches on center with a ET&F 0.100 in. knurled shank X 1.5 in. long X 0.25 in, head diameter pin fastener ID G A J STATE OF 68t JAMES HARDIE BUILDING PRODUCTS, INC. 1-BBS-542-7343 info@jameshardie.com TEST RESULTS: Table I a, Results of Transverse Load Testing RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 Fastener spacing r,, Allowable Frame Ultimate Design Thickness Width Spacing Perimeter Field Load Load' Report Number Test Agency in.) in.) Frame Type in.) Supports Supports Fastener Type PSF) PSF) IC-1270-94 - Ramtech 0*3125 48 2X4 wood Hem -Fir 16 6 6 6d common 149 IC-1270-94 - Ramtech 0.3125 48 2X4 wood Hem -Fir 1-6 4 4 6d common 49.7 78.7 IC-1271-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 24 6 6 236 6d common 94 31.3 IC-1271-94 Ramtech 1 0.3125 48 2X4 wood Hem -Fir 24 4 4 6d common 143 47.7 10868-9711475 Ramtech 0.3125 48 2X4 wood, SG 2t 0.36 16 4 8 4d, 0.091 in. shank X 0.225 in. 90 30.0 HD X 1.5 in. long ring shank nail Min. No- 20 gauge X 3.625 in. X Min- No 8 X 1 in. long X 0.323 in IC-1054-89 Ramtech 0.25 48 1.375 in metal stud 16 6 6 head diameter ribbed bugle 169.9 56.6 head screw Min. No. 20 gauge X 3.625 in. X Min. No 8 X 1 in. long X 0.323 in IC-1055-89 Ramtech 0.25 48 1.375 in metal stud 24 6 6 head diameter dbbed bugle 91.9 30.6 I I head screw Min. No. 20 gauge X 3.625 in. X ET&F 0. IGO irL knuded shank X 11 149-98/1554d Ramtech 0.3125 48 1,375 in metal stud 16 4 8 1.5 in. long X 0.25 in. head 170 56.7 ameter pin fastener Min. No. 20 gauge X 3.625 in. X ET&F 0.100 in. knufled shank X 11149-98/1554d Ramtech 0.3125 48 1.375 in metal stud 24 4 8 1.5 in. long X G.25 in. head 101 33.7 diameter pin fastener 1. Allowable Load is tne Ultimate Load divided by a Factor of safety of 3. 2. HardiePanel Siding complies with ASTM CI 186, Standard Specification for Grade //, 7ype A Non -asbestos Fiber -Cement Flat Sheets. Table 1 b, Shear Values Allowable Loads In Pounds Per Lineal Foot for Panel Shear Walls "' Fastener spacing in-, Frame Ultimate Allowable Thickness Width Spacing Perimeter Field Load 3 Load' Report Number Test Agency in.) in.) Frame Type in.) Supports Supports Fastener Type pit) Of) IC-1273-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 16 6 6 6d common 603.8 201.3 IC-1273-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 16 4 4 6d common 698.8 232.9 IC-1274-94 Ramtech 0.3125 48 ZX4 wood Hem -Fir 24 6 6 6d common 460.0 153.3 IC-1274-94 Ramterh 0.3125 48 2X4 wood Hem -Fir 24 4 4 6d common 637.5 212.5 1086B-97/1475 Ramterh 0.3125 48 2X4 wood, SG a 0.36 16 4 8 4d, 0.091 in. shank X 0.225 in. 595.4 198.5 HD X 1.5 in. long ring shank nail Min. No. 20 gauge X 3.625 in. X Min. No 8 X I in. long X.P.323 in IC-1057-89 Ramtech 0.25 48 1.375 in metal stud1 16 & 24 6 6 head diameter ribbed bugle 990.0 123.8 head screw Min, No. 20 gauge X 3.625 in. X ET&F 0.100 in. knurled shank X 11284-99/1580 Ramtech 0.3125 48 1.375 in metal stud 16 4 8 1.5 in. long X 0.25 in. head 1227.0 153.4 diameter pin fastener Min. No. 20 gauge X 3.625 in. X ET&F 0. 100 in. knurled shank X 11284-9911580 Ramtech 0.3125 48 1.375 in metal stud 24 4 8 1.5 in. long X 0.25 in. head 1060.0 132.5 1 1 diameter pin fastener 1. Aj Doaro eages snaii De supportea Dy Traming. Faneis snail be applied With the long dimension either parallel or perpendicular to studs. 2. The mayumurn height4o4ength ratio for construction in this Table is 2:1. 1 3. In the steel framed assemblies the allowable load is based on the average load at 1/8 inch net deflection. OGA X .......... -I. RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie-com DESIGN WIND LOAD PROCEDURES: Fiber -cement siding transverse load capacity (wind load rapacity) is determined via compliance testing to transverse load national test standards. Via the transverse load testing an allowable design load is determined based on a factor of safety of 3 applied to the ultimate test load. Since the allowable design load is based on factor of safety of 3, allowable design loads on fiber -cement siding correlate directly to required design pressures for Allowable Stress Design, and therefore should be used with combination loading equations for Allowable Stress Design (ASD). By using the combination loading equations for Allowable Stress Design (ASD), the tested allowable design loads for fiber -cement siding are aligned with the wind speed requirements in ASCE 7- 10 Figure 26.5-1 A, Figure 26.5-1 B, and Figure 26.5-1 C. For this analysis, to calculate the pressures in Tables 3, 4, and 5, the load combination will be in accordance with ASCE 7-10 Section 2.4 combining nominalloads using allowable stress design , load combination 7. Load combination 7 uses a load factor of 0.6 applied to the wind velocity pressure. Equation 1, %=0.0025VK,-X-K,-P fref, ASCE 7-10 equation 30.3-1) q2 velocity pressure at height z K, velocity pressure exposure coefficient evaluated at height z K,, topographic factor Kd , wind directionality, factor V , basic wind speed (3-second gust MPH) as determined from [2015 IBC, 2017 FBC] Figures 1609.3(l), (2), or (3),- ASCE 7-10 Figures 26.5-1A, B, or C Equation Z V=Vuk fref. 2015 IBC & 2017 FBC Section 1602.1 definitions) Vuu , ultimate design wind speeds (3-second gust MPH) determined from 12015 IBC, 2017 FBC] Figures 1609.3(l), (2), or (3); ASCE 7-10 Figures 26.5-1 A, 8, or C Equation 3, p=q,*(GC,-GC,) (ref ASCE 7-10 equation 306-1) GCP product of external pressure coefficient and gust -effect factor GC,j product of internal pressure coefficient and gust -effect factor p design pressure (PSF) for siding (allowable desgn load for siding) To determine design pressure, substitute q. into Equation 3, Equation 4, p=0.00256-K K'Kd'\,4(GcrGCpi) Allowable Stress Design, ASCE 7-10 Section 2.4- 1, load combination 7 Equation 5, 0.6D + 0.6W fref. ASCE 7-10 section 2.4. 1, load combination 7) D deadload W , wind load To determine the Allowable Stress Design Pressure, apply the load thctor for W (wind) from Equation 4 to p (design pressure) determined from equation 4 Equation 6, p..d = 0.6*[p] Equation 7, 1p d = 0.6*[0.00256*K,'K-K,'V,,2'(GCP-Gcpi)I Equation 7 is used to populate Table 3, 4, and 5. To determine the allowable ultimate basic wind speed for Hardie Siding in Table 6, solve Equation 7 for V., Equation 8, V, = (p.,10.6*0.00256-K,-K-K,(GC,-GCpi))" Applicable to methods specified in Exceptions I through 3 of[2015 IBC, 2017 FBC) Section 1609. 1. 1-, to determine the allowable nominal design wind speed (Vasd) for Hardie Siding in Table 6, apply the conversion formula below, Equation 9, V, = V. - (0.6)0" fref 2015 IBC & 2017 FBC Section 1609.3. 1j V, , Nominal design wind speed (3-second gust mph) fret 2015IBC&2017FBCSec brtiog,4.ffl"'"",o,. Table 2, Coefficients and Constants -used in Determining V and p, K Wall Zone 5 Height (ft) Exp B Exp C Exp D K. Kd GC, GCO 0-15 0.7 0.85 1.03 h:560 1 0.95 1.4 0.18 20 0.7 0.9 7- 08 1 1 0.85 1.4 0.18 25 0.7 F9 -4 T. 1-2 1 0,85 1.4 0.18 30 0.7 0.98 1.16 1 0.85 1.4 0.18 35 0.73 1.01 1.19 1 0.85 1.4 0.18 40 0.76 1.04 1.22 1 1 1 0.85 1 -1.4 1 0.1 45 ----0.785 1.065 1.2451 1 1 1 0.85 1 -1.4 0.18 50 0.81 1.09 1.27 1 0. 55 0.83 1.11 1.29 1 0.85 1.4 0.18 50 0.85 1.13 131 1 0.85 1.41 0.113 100 0.99 1.26 1.43 1 h160 f 1 0.85 1.8 0.18 VOGAW4 zv I'ju. 0% STAVT, 0 - RONALD 1. OGAWA ASSOCIATES, IN C- 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RJO-26M17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com Table 3, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category B, Wind Speed (3-second gust) 100 105 110 115 120 1 130 140 150 1 160 170 ISO 190 200 210 Height (ft) 8 B B B 6 a B B B B B 8 B B G-15 14.4 15.9 17.5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 20 14.4 15.9 17.5 19.1 20,8 24.4 28.3 32.5 37.0 41.7 46.8 52A 57.8 63.7 25 14.4 15.9 17.5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 30 14.4 15.9 17.5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 35 15.1 16.6 18.2 19.9 21.7 25.4 29 5 33.9 38.6 T3-5 Z.8 54A 60.2 66.4 40 1 -15.7 1 -17.3 19.0 20.7 22.6 26.5 30-.7 40.1 45.3 50.8 56.6 62.7 69.1 45 16.2 17.9 19.6 21.4 23.3 27.4 31.7 35.3 36A 41.5 46.8 52.5 1 -58.5 1 -64.8 1 -7T-4 50 16.7 18.4 20.2 22.11-24.1 28.2 32 3.1 60.3 1 73.7 55 17A 18-9 20.7 22.6 24.7 28.9 6 3 63 1 F;1 R 1 1.9N 1 71.1 60 1 19.3 21.2 237 2-5.2 2-9.6 34.4 39.5 44.9 63.3 100 25.6 28.2 31.0 33.8 36.9 43.3 50.2 57.6 6-1, --i 74 D 1 8- Table 4, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category C, Wind Speed (3-second gust) 100 105 110 115 120 1 130 140 150 160 170 180 190 2DO 210 Height (ft) C C C C C C C C C C C C C C 0-15 17.5 19.3 21.2 23.2 25.2 29.6 34.4 39.5 44.9 50.7 56.8 63.3 70.1 77.3 20 18.6 20.5 22.5 24.6 26.7 31.4 36.4 41.8 47.5 53.7 60.2 670 74.3 81.9 25 19.4 21.4 23.5 25.6 27.9 32.8 38.0 43,6 49.6 56.0 62.8 70.0 77.6 85.5 30 20.2 22.3 24.5 26.7 29.1 34.2 39.6 45.5 51.8 58.4 65.5 73.0 80.9 89.2 35 20.8 23.0 25.2 27.6 30.0 35.2 40.8 46.9 53.3 60.2 67.5 75.2 83.3 91.9 40 21.5 23.7 26.0 28.4 30.9 36.3 42.0 48.3 54.9 62.0 69.5 77.4 85.8 94.6 45 22.0 24.2 1 -26.6 1-29.1 31.6 37.1 43.1 49.4 512 2 5 1 2 3 91.1 22.5 24 8 27.2 29.7 32.4 38.0 44.1 50.6 5 91t U 9 9.2 55 22.9 7-23 -3 25.2 2-5T- 27.7 30.3 33.0 38.7 44.9 51.5 58.6 66.2 74. 82.7 9A 1 01.0607f8-2 30.8 33.6 39.4 5.7---72.4 79-7 67.4 75.5M 84.1 9521 1-11.1 100 32.6 -- 35.9 39.4 43.1 46.9 55.0 63.8 73.3 834 94.1 105.5 117.61 Table 5, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category D, Wind Speed (3-serond gust) 100 105 110 115 120 130 140 150 160 170 180 190 2DO 210 Height (ft) D D D D D D D D D D D D D 5- 0-15 21.2 23.4 25.7 28.1 30 6 35.9 41.6 47.8 54.4 61.4 68.8 76.7 85.0 93.7 20 223 24.6 27.0 29.5 32.1 37.7 43.7 50.1 57.0 64.4 72.2 80.4 139.1 98.2 25 23.1 28.0 3b.6 33.3 39.0 45.3 52.0 59.1 668 74.9 83.4 92.4 101.9 30 23.9 25.5 25.4 29.0 31.6 34.5 40.4 46.9 53.8 61.3 692 77.5 86.4 95.7 105.5 35 24.5 27.1 29.7 32.6 35.3 41.5 48.1 5-5.2 62.8 79.5 88.6 98.2 108.3 40 1 -25.2 1 -27.7 30.5 33.3 36.2, 42.5 49.3 56.5 64.4 70.9 72.7 81.5 90.9 100.7 111.0 45 25.7 28.3 31.1 34.0 37.01 43.4 1 -50.3 -T 57.8 1 -65.7 1 -74.2 1 -83.2 92.7 102. 71 113.3 50 26.2 2&9 g 37.7 44.3 1.3 58.9 67.1 753 84.9 94.6 1048 11.17 55 26.6 7-27 -0 29.3 72-9.8 2.2 3 .2 38.3 45.0 52.2 59.9 i -68.1 76.9 i -86.2 996.1 106 1174 60 7T2-7 735.7 38.9 45. 7 b 3-U I -W-8 6 1.Z tb.1 b 1.b 91.5 100 37.0 40.8 44.7 48.9 53.2 62.5 1 -72.5 1 4 Tables 3. 4, and 5 are based on ASCE 7-10 and consistent Wth the 2015 IBC, 2015 IRC and the 2017 Florida Building Code 7 RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-&47-4595 FAX PROJECT- RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 161 info@jameshardie.com )GAW,4 Table 6, Allowable Wind Speed (mph) for HardlePanel Siding (Analytical Method in ASCE 7-10 Chapter30 CSC Part 1 andPart 73) 2015 18C, 2017 FBC 2015 IBC, 2017 FBC Sim OF : SIONNN- 1 Coefficients used in Table 6 calculations for V Allowable, Ultimate Design Wind, Speed, Viift4,6' 3-second gust mph) Allowable, Nominal Design Wind, Speed, V d 5.6, 3-second gust mph) Applicable to methods specified in [2015 113C. 2017 FBC] Section 1609.1.1. as determined by Figures 1609.3(l),(2), or 3). Applicable to methods specified in Exceptions 1 through 3 of [2015 18C, 2017 FBC] Section Wind exposure category Wind exposure category Siding K Product Product Thickness inches) Width inches) Fastener Type Fastener Spacing Frame Type Stud Sparing inches) Building Height3.7 feet) B G D B I C D Alloable Design Lozid PSF) Exp B Exio C Exp D K. K. GC,, GC, HardiePanelg 5/16 48 6d common 6 2X4 wood Hern-Fir 16 0-15 186 168 153 144 130 118 49.7 0.7 0.85 1.03 hS60 1 Q.a51 1.41 0.18 20 186 164 149 144 127 116 49.7 0.7 0.9 08 1 0.85 1.4 0.18 25 186 160 147 144 124 114 49.7 0,7 0.94 1.12 1 0.85 1.4 0.18 30 186 157 144 1 " 121 112 49.7 07 0.98 1AS I OA5 1-4 0.18 35 182 154 142 141 120 110 49.7 0.73 1.01 1.19 1 0.85 1.4 0.18 40 178 152 141 138 118 109 49.7 076 1 _ TE- 1 0.05 1.4 0.18 4T' 175 150 139 136 117 108 49.7 0.7a5 75E 72 F 1 0.85 1.4 018 50 172 149 138 134 115 107 49,7 0.81 l.D9 1.27 1 0.a5 1-4 0.18 55 170 147 137 132 114 106 491 0.133 1.11 1*29 1 10-851-1. 0.18 60 168 146 136 130 113 105 49.7 0.85 1.13 1.31 1 1 10.851-1.4 0.18 100 139 124 116 108 96 90 49.7 0.99 1.26 1.43 h>60 1 0.851-1.8 0.18 HardiePaneig 5/16 48 6d common 4 2X4 wood Hem -Fir 16 3-15 233 212 192 181 164 149 78.7 0.7_ 0.85 1.03 hs60 1 G.a5 1.4 0.18 20 233 206 188 181 159 146 78.7 0.7 0.9 1.08 1 0.85 1.4 0.18 25 233 201 185 181 156 143 78.7 0.7 0,94 112 1 0.85 1.4 0.18 30 233 197 181 181 _153 140 0.7 098 1.16 1 7-8-5- 71.4 0.18 35 229 194 179 1 177 151 139 78.7 78.7 0.73 1.01 1 0.85 1.4 0.18 40 224 192 177 1 174 148 137 78.7 0.76 1.04 1.19 1. F27 1 0.85 1.4 o.18 45 220 189 7 175 171 147 136 78.7 0,785 1.065 1.245 1 0.85 1.4 0.15, 50 217 ii 173 168 145 134 1 -78.7 0.81 1.09 j 127 1 0.85,-1.4 0.18 55 214 185 172 T7 166 144 133 78.7 0.63 1,11 1 1.29 0.851-1-4 0.18 184 1 164 142 132 78--7 6. E 1.13 1 1.31 1+ 0.851-1.4 0183 155 146 136 120 113 78-7 0.99 1-26 I.L3_ h 60 L 85 1.8 0.18 HardiePanel& 5/16 48 6d common 6 2X4 wood Hem -Fir 24 0-15 147 134 30- 121 114 103 94 3U 0.7 0.85 1.03 lh 60 1 L_ 085 1.4 0.18 20 147 1-19 114 lot- 92 31.3 0.7 0.9 1.08 1 0.85 1.4 0.18 25 147 127 116 114 98 90 31.3 0.7 0.94 1.12 1 G.S5 1.4 0.18 30 147 124 114 114 96 89 31.3 0.7 0.98 1.15 1 1.41 0.181 35 144 123 113 112 95 1 87 1 31.3 0.73 1.01 1.19 1 0.85 14 0.18 40 141 121 112 109 94 86 313 0.76 I.D4 1. 1 0.85 1.4 0.18 45 139 119 110 108 92 86 31.3 0.785 1055, 1.245 1N0. 85 0.85 1.4 0.18 50 137 118 106 91 313 D.Bl 1.09 127 1 085 1.4 0,18 13 5 117 lo5 91 31.3 D.83 1.11 1 1-29 1 0.851-1.4 0.18 116 103 9() 31.3 B5 0.85 1-4 0.18 100 ill 86 31.3 0.99 126 1.43 h,60 1 0,851-1.8 0.18 HardiePane]O 5/16 48 6d common 4 2X4 wood Hern-Fir 24 0-15 182 165 150 141 128 116 47.7 1 7 D.B5 1.03 h;ao I o.a5l 1.4, o.18 20 182 160 T5_7 146 141 124 113 47.7 0.7 0.9 1.08 1 O 851 1.4 1 0.18 25 182 144 141 121 111 47.7 0.7 0.94 1.12 1 0.85 1.4 0).'-' 118 30 182 154 141 141 119 1D9 47.7 0.7 0.98 1.16 1 0.85 1-4 0.18 35 178 151 139 138 117 108 47.7 0.73 1-Di 1.19 1 0.85 1.4 0,18 40 174 149 138 135 116 107 47.7 0.76 1.D4 1.22 1 0.85 1.4 01. 0-18 45 172 147 136 133 114 106 47.7 0.785, I.D55, 1-245 1 0-85 1.4 0.18 50 169 146 135 131 113 105 47.7 0.81 I.D9 1.27 1 0.85 1.4 01 IK 144 134 129 112 104 0.83 1.11 1. T9 1 0.115 1 A 0.18 W E5 1 143 133 128 111 103 47.7 47.7 0.85 1.13 1.31 1 13.85, 1.4 0.18 100 137 1 121 114 106 94 88 47.7 099 126 1.43 h>60 1 0.851-1.8 0.18 HardiePane]5 5/16 48 4d, 0.091 in. shank X 0.225 in. HD X 1.5 in. long ring shank nail 4 edge 8 field 2X4 wood SGZ,.0.36 16 0_15 144 131 119 112 101 92 30.0 0.7 D.B5 1.03 hS60 1 0-851-1.4 0.18 20 144 127 116 112 98 90 30.0 0.7 0.9 1.08 1 0.851-1.4 0.18 25 144 124 114 112 96 88 30.0 0.7 0.94 1.12 1 0.85 1.4 0.18 30 144 122 112 112 94 87 30.0 0.7 , 0.98 1.16 7 0.85 774 0.18, 35 141 120 111 1 109 93 86 30.0 0.7L3 1.01 1.19 1 0.85 1.4 D.18 40 138 107 92 30.0 0.76 1.22 1 0.85 1.4 0.18 45 136 117 105 91 30.0 0785 1.066 1.245 1 0.85 1.4 r-1,4 0.18 50 34 116 104 89 30.0 081 El. D4 1.09 U70 085 1.4 0.18 55 132 114 103 89 30.0 0.83 1.111, 1.29 1 0.85 0,16 60 131 113 101 88 30.0 0.85 113 1.31 1 0.85 1.4 6 _1B t 1 3 1 RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. I-BBB-542-7343 info@jameshardie.com 2015 IBC, 2017 FBC 2015 IBC, 2017 FBC Allowable, Ultimate Allowable, Nominal Design Wind, Speed, Design Wind, Speed, V"4'15. V.2.6. 3-second gust mph) a -second gust mph) Applicable to methods App licable to methods specified in 12015 IBC I specified in Exceptions 1 2017 FBC) Section thmugh 3 of f2015 IBC, 1609-1.1. as determined by 2017 FBC] Section Figures 1609.3(1),(2), or 1609.1.1. 3). Coefficients used in Table 6 calculations for V.,, j-V1r-,ndM-p..u,e category Wind exposure category Siding Product Stud Building Allowable Product Thickness Width Fastener Fastener Frame Spacing HeigW" B C D B D Design inches) inches) Type Spacing Type inches) feet) Load PSF) Exp B Exp C Exp D 11 K I GC' GCj 0-16 198 180 163 163 139 125 56.6 0.7 0.85 1.03 hs60 1 0.851-1.4 0.18 20 198 175 159 153 135 123 56.6 0.7 0.9 1.08 1 0.851-1.4 0,18Min. No 8 X 25 198 171 157 153 132 121 66.6 0.7 0.94 1.12 1 0-851-1.4 0.181 1 in. long X Min. No. 30 19B 167 154 153 130 119 56.6 0.7 0.98 1.15 0.85 1.4 0.18 0.323 in 20 ga. 35 194 165 152 150 128 118 56.6 0.73 1.01 1.19 1 1 0.85 1.4 0.18head33millX 40 190 162 150 147 126 1`16 56.6 0.75 1.04 1.22 1 0.85 1.4 0.18HardiePanel(D 114 48 diameter 6 3.625 in, 16 45 187 161 148 145 124 115 566 0.785 1.065 1.245 0.85 1.4 CAB ribbed X 1.375 50 184 159 147 143 123 1 114 56.6 0.81 1.09 1.27 L 1 0.85 1-4 0.18buglehead in metal 55 182 167 146 141 122 113 56.6 O 83 1.11 1-29 1 O.a5 1.4 0.18 scre4 stud 60 180 156 145 139 121 112 56.6 0.85 1.13 1.31 1 0.85 1.4 018 100 149 132 124 115 102: 96- 55.6 0.99- 125 1.43 h>50 1 0:85 1-1:13 , 0:18 0-15 146 132 120 113 102 93 30.6 0.7 0.85 1.03 hs50 1 0.85 1.4 0.18 Min. No 8 X 20 146 128 117 113 99 91 30.6 0.7 0.9 1.08 1 0.85 1.4 0.18 25 146 126 115 113 97 89 30.6 0.7 0.94 1.12 1 0.85 1.4 DAT I in. long X Min. No. 30 146 123 113 113 95 88 30.6 0.7 0.98 1.16 1 F.- 85 1.4 C718 0.323 in 20 ga. 35 143 121 112 110 94 86 30.6 0.73 1.01 1.97 1 CA5 1.4 0.18 head 33 mil) X 40 140 119 Ila 108 93 85 30.6 0.76 1 04 1.22 1 0.85 1.4 0.18HardiePanel@11448 diameter 6 3,625 in. 24 45 137 118 106 91 30.6 0.785 I.D65 1.245 1 0.85 1.4 0.18. ribbed X 1.375 50 117 105 90 30.6 0.81 1.09 1.27 1 0.85 1.4 0-18 bugle head in metal 55 134 116 104 90 30.6 0.83 1.11 I i 0.851 1.4 7-18- screv stud 60 132 115 102 89 30.6 0.85 1.13 L29 1.31 1 10.851 1.4 0-18 100 30.6 0.99 1.26 1.43 h>50 1 0.851-1.8 0-18 ET&F 0-15 198 180 163 153 139 127 56.7 0.7 0.85 1.03 hs6D 0.115 1.4 018 20 198 175 160 153 135 124 567 0.7 0.9 1.08 L 1 0.85 1-4 0.18 0. 100 in. knurled Min. No. 25 198 171 157 153 132 121 56.7 0.7 0.94 1.12 1 1.4 0 18 30 198 167 154 153 130 119 56.7 0.7 0.98 1.16 1 0.85 1-4, 018, shank X 20 ga. 35 194 165 152 150 128 118 56.7 0.73 1.01 1 1.19 1 0.85 1.4 0.181.5 in. long 4 edge 33 mil) X 40 190 163 150 147 126 116 56.7 0.75 1.04 1.22 1 0.85 1-4 0.18HardiaPanel& 5116 48 X 0.25 in. 8 field 3.625 in. 16 45 187 161 149 145 124 115 56.7 0385 1.065 1.245 1 0.85 1.4 U. 1-8 head X 1.375 50 184 159 147 143 123 114 56.7 0.131 1.09 1 27 1 0.8 1.4 0.18 diameter in metal 55 182 157 146 141 122 113 56.7 083 1.11 1.29 1 O.a5 1.4 0.18stud pin fastenel-2 60 180 156 145 139 121 112 56.7 0.85 113 1.31 1 0.85 1.4 0.18 100 149 132 124 115 102 96 56.7 0.99 1.26 1.43 h>60 1 0.851-1.8 0.18111 0-15 153 139 126 118 107 98 33.7 0.7 0.85 1.03 h:550 1 0.851-1.41 0.18ET&F 0. 100 in. 2D 153 135 123 118 104 95 33.7 0.7 0.9 , 1.08 1 0.a5j 1.4 1 0.18 25 153 132 121 118 102 94 33.7 0.7 0.94 1.12 1 0.85 1A 0.18 knurled Min. No. 30 153 129 119 118 100 92 33.7 0.7 0.98 1.16 1 0.851 1.4 10.18shankX20ga. 35 150 127 117 116 99 91 33.7 0.73 1.01 1.19 1 0.85 1.4 0.181.5 in. long 4 edge 33 mil) X 40 147 125 116 114 97 90 33.7 0.76 1 1)4 1.22 1 0-85 1.4 018HardiePanelO5/16 48 X 0.25 in. 8 field 3.625 in. 24 45 144 124 115 112 96 89 33.7 0.795 I.D65 1.245 1 0.85 1.4 0.18 head X 1 375 50 142 122 113 110 95 88 33.7 0.81 1.09 1.27 1 0.85 1.4 0.18 diameter in metal 55 140 121 113 109 4 93 87 33.7 093 111 129 1 0.85 1.4 0.18stud pin fastener2 60 139 120 112 107 t 87 33 7 085 113 L'i 1 0.85 1.4- 77 100 115 E 33!7 0!99 1 ii wo I M. 1.8 0j8 1. 6crews shall penetrate the metal traming at least three full threads. 2. Knurled shank pins shall penetrate the metal framing at least 114 inch. 3. Building height = mean roof height (in feet) of a building, except that eave height shall be used for roof angle 0 less than or equal to 10* (2-12 roof 4. V,& = ultimate design wind speed 5. V.., = nominal design wind speed 6. Linear interpolation of building height (s 60 it) and wind speed is permitted. 7. Wind speed design assumptions per Analytical Method in ASCE 7-10 Chapter 30 C&C Part I and Part 3: K=I, K=0.85, GC,=-1.4 (h560), GCp' LIMITATIONS OF USE: I) Fastener pullout must be evaluated when installed a species of wood studs other than that which was tested- 2) In High Velocity Hurricane Zones (HVHZ) install per Miamim-Dade County Florida, NOA 17-0406.06 IR'..' ........... E NA'S- Y. C"TI-= 4Z7 ie" T - i'ON Florida Building Code Online Page I of 2 Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method N Alpha Aluminum, Inc. 1710 Premier Row Orlando, FL 32809 407) 509-2008 alphaaluminuminc@yahoo.com Luis Lomas rllomas@lrlomaspe.com Panel Walls Soffits Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer El Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Luis R. Lomas Evaluation Report Florida License PE-62514 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/30/2023 Validated By Steven M. Urich, PE 11 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL16544 R3 COI FLCOI.odf Standard ASTM E330 Year 2002 EZI affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity 0 Yes Q No 0 N/A https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvqqu2w/2b... 11/15/2018 Florida Building Code Online Page 2 of 22n FL16544 R3 COC FL16544-R3-COMP.pd Product Approval Method Method I Option D Date Submitted 01/12/2018 Date Validated 01/12/2018 Date Pending FBC Approval Date Approved 01/14/2018 Summary of Products r- I FL # Model, Number or Name Description 16544.1 Alpha Aluminum Solid & Vented Alpha Aluminum Solid & Vented Aluminum Soffit/ CMU & Aluminum Soffit/ CMU & Wood Wood Limits of Use Installation Instructions Approved for use in HVHZ: No FL16544 R3 IT 08-02198A.r)df Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO INSTALLATION INSTRUCTIONS FOR FL16544 R3 AE 512914A.Ipd DESIGN PRESSURE RATINGS. Created by Independent Third Party: Yes F- T 1 F - -- ' Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen _::_Accessibility Statemen :: Refund Statemen under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Appro val Accepts: rM = ia M Credit Card Safe https://www.floridabuilding.org/pr/pi7_app_dtl.aspx?parain=wGEVXQwtDqvqqu2w`/`2b... 11/15/2018 3 23/32" r17/ 32" 9/32" 1/81, 1/2" 16 5/8" 4 9/32" 7/8" 4 9/32" 7/8" 1/2" 11-1 1 4 3/4" 16" ALUMINUM SOFFIT- SOLID AND VENTED 0 3105 H28 ALUMINUM.012" THICK VENTED VERSION VENTED AREA: 20.25 IN21LINEAR FOOT DESIGN PRESSURE RATING IMPACTRATING 54.2PSF NONE WHEN INSTALLED IN 12"OVERHANG DESIGN PRESSURE RATING IMPACTRATING 38.4PSF NONE WHEN INSTALLED IN 16'OVERHANG DESIGN PRESSURE RATING IMPACTRATING 3 1. 1 PSF NONE WHEN INSTALLED IN 24"OVERHANG TABLE OF CONTENTS SHEET NO. DESCRIPTION 1 PROFILES AND NOTES 2 — 3 INSTALLATION DETAILS AND COMPONENTS REVISIONS DESCRIPTION ITIE NPPIIIIED I A IREVISED DIMENSIONS AND MATERIAL GRADEJ 11/13/14 1 R.L. I NOTES: 1 . THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE, 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4. FRAME MATERIAL: COLD ROLLED FORM ALUMINUM 3105-1-128. 5. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE 1 3/4" TRIM PAINTED STAINLESS STEEL NAILS WITH 1/4" HEAD DIAMETER. 3/4"Xl/4" CROWN OR 3/8"X3/8" STAPLES. REFER TO DETAILS A, B, C, AND E FOR MINIMUM EMBEDMENT AND SPACING. 6. FOR ANCHORING INTO MASONRY/CONCRETE USE .097" DIAMETER T NAILS OR STUB NAILS REFER TO DETAIL D FOR MINIMUM EMBEDMENT AND SPACING. 7. ALL FASTENERS TO BE CORROSION RESISTANT. 8. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACFURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED EELOW- A. WOOD — MINIMUM SPECIFIC GRAVITY OF G 0.42 D. CONCRETE MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. C. MASONRY STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE I (OR GREATER). ALPHA ALUMINUM INC. 1710 PREMIER ROW ORLANDO, FL 32809 16" ALUMINUM SOFFIT PROFILES AND NOTES DRAWN: DWC NO. V. L. 08-02198 S I DATE 08/05/13 ls"7E TlOF 3 SIGNED: 1211112014 ca 04f E Ny, -1 p o 610or TMTOF""' 0, 77 Mt*-ZORO` A ONAL BILL OF MATERIALS ITEM NO.: PART NUMBER I DESCRIPTION I MANUFACTURER MATERIAL i ISOFFIT JALPHAALUmrNum INC IALUMINUM3105-1-128 2 IFCHANNEL IALPHA ALUMINUM INC JALUMINUM31OS-H28 FRAME BUILDING BY OTHERS SEE ilDETAILS A B AND C SkEET 3 12" OVERHANG 12" OVERHANG INSTALLATION DETAIL 3/4" F i15/16" 1/2" F CHANNEL 3104-H28 ALUMINUM. 0 12" THICK FRAME BUILDING BY OTHERS SEE SEE il SEE - DETAIL E DETAILS DETAIL E SHEET 3 A, B AND C SHEET 3 SHEET 3 16" OVERHANG 16" OVERHANG INSTALLATION DETAIL REVISIONS DESCRIPTION I DATE 1 -11-1. REVISED DIMENSIONS AND MATERIAL GRADE 1 11/13/14 1 R.L. FRAME BUILDING BY OTHERS EXTEROR X FURRING SEE TRIP SEE DETAILS DETAIL L A, B AND C SHEET 3 SHEET 3 SEE DETAIL D SHEET 3 12" MAX O.C. 24" OVERHANG 24" OVERHANG INSTALLATION DETAIL ALPHA ALUMINUM INC. 1710 PREMIER ROW ORLANDO, FL 32809 16" ALUMINUM SOFFIT INSTALLATION DETAILS rAWN: OWG NO. L. 08-02198 SCALE NTS I DATE 08/05/13 ISHEET2 OF 3 SIGNED: 1211112014 0 N IV TATt OF OR%'D A / psl/ ONA It I it I I \%\\ 1 1/4" MIN EMBEDMENT DETAIL A WOOD FRAMING INSTALLATION WIF CHANNEL AND NAILS 1 3/4" TRIM PAINTED SS NAIL W/l/4" HEAD DIAMETER LOCATED 24" MAX D.C. 3/8" MIN EDGE DISTANCE 3/4"XI/4" CROWN STAPLES LOCATED 24" MAX O.C. IN DIAMOND PATTERN WOOD FRAMING INSTALLATION WIF CHANNEL AND STAPLES 5/8" MIN EMBEDMENT T NAIL OR STUB NAIL 097" DIAMETER LOCATED 24" MAX D.C. 3/8" MIN EDGE DISTANCE DET) MASONRYICONCRETE INSTALLATION WIF CHANNEL AND NAILS I - 11- 1 -- I IVI 24"OVERHANG 318" BETWEEN STAPLES 8" BETWEEN STAPLES DETAIL F STAPLE DIAMOND PATTERN. REVISIONS DESCRIPTION REVISED DIMENSIONS AND MATERIAL GRADE 1 11/13/14 1 R.L. FASCIA TRIM 1 3/4" TRIM PAINTED SS NAIL W/l/4" HEAD DIAMETER 1) PER PANEL MIN 3/4"XI/4" CROWN STAPLE EMBEDMENT 1) PER PANEL 3/4"Xl/4" CROWN STAPLE OR 3/8"X3/8" STAPLE LOCATE (1) AT EACH GROOVE 2-- 1/4" FASCIA LIP 1 3/4" TRIM PAINTED SS NAIL 3/8" MIN W/l/4" HEAD DIAMETER EDGE DISTANCE LOCATED 24" MAX D.C. DETAIL E WOOD FRAMING INSTALLATION FASCIA SIDE ALPHA ALUMINUM INC. 1710 PREMIER ROW ORLANDO, FL 32809 16" ALUMINUM SOFFIT INSTALLATION DETAILS DRAWN: OWC NO. V. L. 08-02198 SCALE NTS I DATE 08/05/13 SHEET 3 OF 3 SIGNED: 1211112014 o\llIII.I////'/ 0 1 / o 6V IF 0. TATrOF ZZ TEV Z 40RI'O" A Y/ON'Ai- 0111111100 Florida Building Code Online Paoe I of 3 I t, 0 1-411. - =-5- ", 01, BCIS Home Log In 1 User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search dbpr Roxta L41% Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application Lis > Application Detail FL # FL7006-RlO Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer IKO Industries, Ltd Address/Phone/Email 40 Hansen Road South Brampton, NON -US L6W 31-14 708) 496-2800 Ext 200 rmetzOO1@tampabay.rr.com Authorized Signature Robert Metz rmetzOO1@tampabay.rr.com Technical Representative Bob Metz Address/Phone/Email REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 727) 776-5261 rmetzOOI@tampabay.rr.com Quality Assurance Representative Don Shaw Address/Phone/Email IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 717) 579-6706 don.shaw@iko.com Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency FM Approvals - CER Validated By Locke Bowden 6 Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year ASTM D3161 modified to 110 mph 2016 ASTM D3462 2010 ASTM D7158 Class H 2011 ASTM E108 2011 Equivalence of Product Standards Certified By https://www.floridabuilding.org/Pr/Pr_app_dtl.aspx?param=wGEVXQwtDqse7mYBd2b-'IK... 2/6/2018 Florida Building Code Online Pacye 2 of 3C) Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method I Option A 10/08/2017 10/30/2017 11/01/2017 FL # Model, Number or Name Description 7006.1 Cambridge, Cambridge HD, Laminated architectural fiberglass asphalt shingle Biltmore and Biltmore HD manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.; Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL7006 R10 C CAC Letter - ASTM D3161 letter - (9-26- 2017) from FM.pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL7006 R10 C CAC Letter - ASTM D3462 letter - (9-26- 2017).pdDesignPressure: N/A Other: FL7006 RIO C CAC Letter - ASTM E108 letter - (9-26- 2017M)d Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 R10 11 IKO-187-02-01 Letter - Installation Instructions for FBC FL7006.1)d Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.2 Hip and Ridge 12 Cap This is a 12" x 12" fiberglass asphalt shingle used to cover the hip and/or ridge of an asphalt shingle roof system manufactured at IKO's Kankakee, IL, Toronto, Ont. and Brampton, Ontario plants. Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL7006 RIO C CAC ASTM D 3462 - Shingle lette Surveillance Audit Location - (6-28-2017),pdApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL7006 R10 C CAC Letter - ASTM D3161 letter - (9-26- 2017) from FM.pdfDesignPressure: N/A Other: FL7006 R10 C CAC Letter - ASTM D3462 letter - (9-26- 2017),od FL7006 R10 C CAC Letter - ASTM E103 letter - (9-26- 2017).pd Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 R10 II Hip and Ridge Cap Shinale Installation Instructions. 1)d FL7006 R10 II IKO-187-02-01 Letter - Installation Instructions for FBC FL7006.1)d Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.3 Leading dge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at Starter Strip the bottom of a roof system manufactured in Brampton and Hawkesbury, Ontario plants Limits of Use Certification Agency Certificate Approved for use-;n-HVHZ: Yes F1.7.0.06 R10 C CAC Letter - ASTM D3161 letter - (9-26- 2017) from FM.i)dfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL7006 RIO C CAC Letter - ASTM D3462 letter - (9-26- 2017).r)dDesignPressure: N/A Other: FL7006 R10 C CAC Letter - ASTM E108 letter - (9-26- 2017).Dd Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 RIO 11 IKO-187-02-01 Letter - Installation Instructions for FBC FL7006.pd FL7006 R10 11 Roofino-Products-Leading-EdQe-Plus- Application-EN(I).0f Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: https://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=wGEVXQwtDqse7mYBd2b3K... 2/6/2018 Florida Building Code Online Page 3 of 3 7006.4 Marathon Plus AR, Superglass Plus 3 tab fiberglass asphalt shingle manufactured at IKO's AR Brampton, Ontario, Hawkesbury Ont., Toronto, Ont.; I I Sylacauga, AL and Kanakakee, IL plants Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other - Certification Agency Certificate FL7006 RIO C CAC Letter - ASTM D3161 lettter - (9-26- 2017) from FM,pdf FL7006 R10 C CAC Letter - ASTM D3462 letter - (9-26- 2017),nd FL7006 R10 C CAC Lettgr - ASTM E108 letter - (9-26 2017).Qd Quality Assurance Contract Expiration Date 12/20/2020 Installation Instructions FL7006 R10 II IKO-187-02-01 Letter - Installation Instructions for FBC FL7006.pd Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: F..ck] Flle.], Contact U :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Staternen :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record, If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: MCI W, KEE https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqse7mYBd2b3K... 2/6/2018 Z, III pi 1 111 1111 1 - 0." L_.'tW_,; T E C H N 0 L 0 G I E S October 27, 2017 IKO Industries, Ltd 120 Hay Rd. Wilmington, DE 19809 Re: FBC FL7006 Sir(s), PRI Construction Materials Technologies has completed a technical review and attached sealed shingle instructions in compliance the 2017 Florida Building Code. This review was completed based on the receipt of following evidence from IKO Industries, Ltd: 1) IKO Shingle Application Instructions — 3-Tab Shingles EN-3Tab_AppIns_8AGXEFS-2012-1 1—reformatted 2013-02-revO7/13-Florida) 2) IKO Laminated Shingles Application Instructions EN -Laminated — AppIns — 8TTEFS-2012-04—reformafted 2013-02-revO7/13-Florida) 3) IKO Hip and Ridge 12 Application Instructions E N-H ipa In d Ridge 123 H RTri-201 3-08—reform atted 2013-08) 4) IKO Leading Edge Plus Shingle Application Instructions EN-3LEP-Tri-2012-06—reformatted 2013-03) 5) ASTM D3161 Test Report (FM Approvals Project No. 3040947) The attached instructions should be used in conjunction with the published manufacturer's application instructions and applicable code. In the event the instructions conflict, these instructions shall govern. Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. 7Signed: x l k Signed Date: Brad GrzyboWski Managing 134rector October 27, 2017 Date Attachments: A) IKO Shingle Application Instructions - 3-Tab B) IKO Laminated Shingles Application Instructions C) IKO Hip and Ridge 12 Application Instructions D) IKO Leading Edge Plus Application Instructions IKO-1 87-02-01 A -A ------ Duc L_,JNuXen Florida Rb4ist'6—red Professional Engineer P.E. Number: 65034 October 27, 2017 PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FIL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: mate alstesfing@pdcmt.com WebSite: http:/AAw.p cmt.com IKO Installation Instructions for Asphalt Shingles Page 2 of 5 IKO Shingle Application Instructions — 3-Tab Shingles ASTM D3161, Class F — IKO Marathon 25 AR and CRC Superglass M25AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING:Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed 6-1/8" above the butt edge, approx. 1 " and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21" perfoot (60') or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1 " diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should sea[ to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8". STEEP SLOPES 1 1 1 1 'ZI SEALING STRIP NAILS K-- NAILS DO NOT NAIL INTO OR ABOVE THE SEALING STRIP FRI Construction Matedals Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: mate aistestng@pricmt.com WebSite: http:/A~.pdcmt.com IKO Installation Instructions for Asphalt Shingles Page 3 of 5 IKO Laminated Shingles Application Instructions ASTM D3161, Class F — Cambridge, Cambridge HD, and CRC Biltmore AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT: Applied in accordancewith building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed in the nail line 7-3/8" below the top edge, approx. 1 " and 13" in from each end. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21 " per foot (60') or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Sea] down each shingle at time of application with three 1 " diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8". C 3/ NAIL LINE NAILING - STEEP SLOPES APPLICATION Use sk nails as shown- 17 F- 1 CEMENT PROPER APPLICATION REQUIRES TFAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OF THE SHINGLE PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5940 e-mail: matehaistesting@p cmt.com WebSite: http:/Mw.pdcmt.com IKO Installation Instructions for Asphalt Shingles Page 4 of 5 IKO Hip and Ridge 12 Application Instructions ASTM D3161, Class IF — IKO Hip and Ridge 12) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are designed for a 5 1/8" (130 mm) exposure. (For a neater appearance, the top of each side of each piece has been factory trimmed on a 1 " (25 mm) taper (see drawing). Bend each piece over the hip or ridge, and nail 5 5/8" (143 mm) above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 1/8" (130 mm). Apply hip pieces starting at the lower end of the hip, working up toward the ridge. On hip roofs, apply ridge pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end opposite to the prevailing wind direction and continue to the other end. Note: To obtain a three-dimensional effect, (which is recommended, but not required), apply hip and ridge shingles double thickness by stacking 2 pieces on top of one another, the lower piece extending about 3/4" (19 mm) further than the top piece (see diagram). The final shingle should be set in cement, and the exposed nail heads of the final shingle should be covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for easier%bending. NOTE: 8HINGLES MUST BE APPLIED PROPERLY. THEYARE DESIGNED FOR USE AS HIP AND RIDGE SHINGLES ONLY, AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POORAPPLICATION OR FAILURE TO PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS. REVIEW ALL APPLICABLE BUILDING CODES, MINIMUM PROPERTY STANDARDS, AND REQUIREMENTS PRIOR TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. 21, TAPER CUT PRI Construction Matedals Technologies, LLC. 6412 Badger Drve Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5940 e-mail: matedalstesting@pricmtcorn WebSite: http:/Akww.p cmt.com IKO Installation instructions for Asphalt Shingles Page 5 of 5 IKO Leading Edge Plus Application Instructions ASTM D3161, Class F — IKO Leading Edge Plus) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. 1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required. 2. Each 39 3/8" x 13 1/4" (1000 mm x 336 mm) IKO Leading Edge Plus strip is perforated lengthwise for separation into two (2) shingles. Take one IKO Leading Edge Plus strip and fold flat at perforation to separate. 3. Take one of the separated shingles 39 3/8" x 6 5/8" (1000 mm x 168 mm) and remove approximately 20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up, with the factory installed sealant adjacent to the eaves. The shingle should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with nails located 3" to 4"(75 mm to 100 mm) from the eave edge and 1" (25 mm) in from each end. 4. Take the leftover 20" (500 mm) piece shingle. Rotate the piece and align it vertically up the rake edge with, the factory installed sealant adjacent to the outer edge of the roof. The shingle should overhang the rake edge by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with fasteners located 3" to 4" (75 mm to 100 mm) from the rake edge and 1 " (25 mm) in from each end. 5. Repeat Steps 3 — 4 for the right lower corner of the roof deck. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" (9 mm) diameter heads, long enough to penetrate through plywood or 3/4"(20 mm) into boards. Use 4 nails per shingle placed 3" to 4" (75 mm to 100 mm from the eave edge and approximately 1 " and 13" (25 mm and 330 mm) in from each end. 6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck. Install the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingles to the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge, 4 nails per shingle. 7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first -course field shingles and help keep them from lifting in high winds. PM Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: matedalstesfing@pdcmt.com WebSite: http:/Ahww,pdcmt.com Florida Building Code OnlineZ:' Page I of 2 BCIS Home 'I Log In 1 User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search dbt,O%L LP Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application Lis > Application Detail FL # FL15216-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email InterWrap, Inc. 32923 Mission Way Mission, NON -US 00000 551) 574-2939 mtupas@interwrap.com Eduardo Lozano elozano@interwrap.com Technical Representative Eduardo Lozano Address/Phone/Email 32923 Mission Way Mission, NON -US 00000 778) 945-2891 elozano@interwrap.com Authorized Signature Quality Assurance Representative Address/Phone/Email Category Rooflng Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0' Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 09/30/2019 Validated By 3ohn W. Knezevich, PE W Validation Checklist - Hardcopy Received Certificate of Independence FL15216 R3 COI 2017 01 COI Nieminen,pd Referenced Standard and Year (of Standard) Standard Yea ASTM D1970 (tear) 2015 ASTM D226 (physicals) 2009 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app—dtl.aspx?pa,ram=wGEVXQwtDqv-'IyVVKJZ IQ... 2/6/2018 Florida Building Code Online1 Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 10/10/2017 10/11/2017 10/15/2017 12/12/2017 FL At Model, Number or Name Description 15216.1 RhinoRoof Underlayments Synthetic roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL15216 R3 11 2017 10 FINAL ER INTERWRAP RHINOROOF FL15216- R3.odApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: See ER Section 5 for Limits of Use. Evaluation Reports FL15216 R3 AE 2017 10 FINAL ER INTERWRAP RHINOROOF FL15216- R3.pd Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-182 The State of Florida is an AA/EEO employer. Copyriaht 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statement :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Appro al Accepts: M = LMR-91 99 E https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ IQ... 2/6/2018 ERDRIINJIT EVALUATION REPORT Interwrap, Inc. 32923 Mission Way Mission, BC V2V-6E4 Canada 551) 574-2939 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 140510.02.12-113 FI-15216-113 Date of Issuance: 02/17/2012 Revision 3: 10/10/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6t' Ed ition (2017) Florida Building Code sections noted herein. DESCRIPTION: RhinoRoof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/10/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY4 ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: RhinoRoof Underlayments, as produced by Interwrap, Inc., has demonstrated compliance with the following sections of the 6 1h Edition (2017) Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Properties Standard Year 1507.1.1, T1507.1.1 Unrolling, Breaking Strength, Pliability ASTIVI D226 2009 1507.1.1 Tear Strength ASTIVI D1970 2015 3. REFERENCES: gn Examination Reference Date ITS(TST1509) Physical Properties 100539395COQ-006 10/27/2011 ITS(TST1509) Physical Properties 100539395COQ-002 10/27/2011 ITS(TST1509) Physical Properties 100539395COQ-006 03/14/2014 PRI (TST5878) ASTM D1970; Tear strength OCF-330-02-02 10/03/2017 ITS (QUA.1673). Quality Control Service Confirmation 09/30/2017 4. PRODUCT DESCRIPTION: 4.1 RhinoRoof U20 is a multilayered polymer woven coated synthetic roof underlayment available in 42-inch wide rolls, and can be produced in various other sizes; meets FBC 1507.1.1 (Exception). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 RhinoRoof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: P", 0W Air4 0 i.:'Ro ON k, P, Asphalt Wood Shakes Slate or Underlayment Shingles Nail -On Tile Foam -On Tile Metal Shingles Simulated Slate RhinoRoof U20 g N 5.6 Exposure Limitations: RhinoRoof U20 shall not be left exposed for longer than 30-days after installation Exterior Research and Design, LLC. Evaluation Report 140510.02.12-113 Certificate ofAuthorjwtion #_q503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL15216-R3 RhinoRoof Underlayments Revision 3: 10/10/2017 Page 2 of 3 TRINITY, ERD I 6. INSTALLATION: 6.1 RhinoRoof Underlayments shall be installed in accordance with Interwrap, Inc. published installation 6.3.1 Fasteners: For exposure < 24 hours, corrosion resistant fasteners may be 1-inch roofing nails with a 3/8-inch diameter head, or those noted in 6.4.2. The use of staples is prohibited. For exposure > 24 hours up to maximum 30 days, corrosion resista nt fasteners shall be minimum 1-inch diameter plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough edge facing up). The use of staples is prohibited. 6.3.2 Single Laver; Roof Slope > 4:12: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. Refer to Interwrap, Inc. recommendations for alternate lap configurations and/or the -use- of -sealant under -certain conditions. For exposure < 24 hours, use of every -other fastening location printed on the surface is acceptable. For exposure > 24 hours up to maximum 30-days, use of every fastening location printed on the surface is required. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens on the same day. Battens shall not be positioned over cap nails. If this occurs, remove the cap nail and patch the hole in accordance with Interwrap published instructions. 6.4.3 Double Laver; 2:12 < Roof Slope < 4:12: End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum half -sheet -width plus 1-inch. Double layer application; begin by fastening a half -width plus 1-inch starter strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.5, but maintaining minimum half -width plus 1-inch side (horizontal) laps, resulting in a double -layer application. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Qingdao, China 9. QUALITY ASSURANCE ENTITY: Intertek Testing Services NA Inc. — QUA1673; (608) 836-4400 END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 140510.02.12-113 Certificate ofAuthorization #9503 6 T" EDITION (2017) FBC NON-HVHZ EVALUATION FL15216-R3 RhinoRoof Underlayments Revision 3: 10/10/2017 Page 3 of 3 p' RhinoRoof' U20 Installation Instructions RhinoRoof' U20 is an air, water and vapor barrier and therefore must be installed above a properly ventilated space(s). Follow ALL building codes applicable to your geographical region and structure type as it is considered a vapor barrier. DECK PREP: Protrusions from the deck area must be removed and decks shall have no voids, damaged or unsupported areas. Deck surface should be free of debris, dry and moisture free. USE: RhinoRoof' U20 must be covered by primary roofing within 60 days of application. U20 is designed for use under; asphalt or synthetic shingles, metal in residential applications, and cedar shakes that have been primed. APPLICATION: For slopes from 4:12 and higher RhinoRoof' U20 is to be.. laid out horizontally (parallel) to the eave with the printed side up. Horizontal laps should be 4" and Vertical laps should be 6"and anchored approximately 1 " in from the edge. For low slope applications it is recommended to overlap 50% plus 1 ", for complete definition of low slope and guidelines consult authorities having jurisdiction. U20 product is not recommended for slopes less than 2:12. The use of roofing hammer, pneumatic air or gas driven fastener tools is acceptable. The use of straight edge cutting knives is recommended. FASTENERS: For same day coverage with primary roofing RhinoRoof' U20 can be anchored with corrosive resistant 3/8" head x 1 " leg roofing nails (ring shank preferred, smooth leg acceptable). The use of every other anchoring location printed on the product is also acceptable. If U20 will be left exposed for up to 60 days the product must be anchored with 1 " plastic or metal cap smooth or ring shank roofing nails and anchored in all locations printed on the facer DO NOT USE STAPLES: the use of staples to penetrate RhinoRoof' U20 will void warranty. ANCHORING: All anchoring nails must be flush, 90 degrees to the roof deck, and tight with the underlayment surface and the structural roof deck. Where seams and joints require sealant or adhesive use a low solvent plastic roofing cement meeting ASTM D-4586 Type 1, or Federal Spec SS-153 Type 1 such as Karnak, Henry, DAP, MB, Geocel or equivalent. Acceptable alternatives are butyl rubber, urethane, and EDPM based caulk or tape sealant. 4Ucje" EXTENDED EXPOSURE: If RhinoRoof' U20 product will be exposed longer than 24 hours and up to 60 days then product must be attached to the structural roof deck using a minimum 1 " diameter plastic or metal cap roofing nails (ring shank preferred but smooth leg acceptable). Miami Dade approved tin tags/metal caps are also acceptable, and it is recommended for best performance to use with the rough edge facing up. For extended exposure it is always recommended to anchor on every printed position on the facer. RhinoRoof' U20 is not designed for indefinite outdoor exposure. For extended exposure conditions where driving rain or strong winds are expected it is recommended to take additional precautions such as doubling the lap widths. Alternately or in addition to a compatible sealant could be used between the laps or a peel and stick tape could be applied to the overlaps. CAUTION - READ GOOD SAFETY PRACTICES BELOW Good safety practices should be followed on steep slope roofs, such as use of tie -offs, toe boards, ladders and/or safety ropes and personal body harnesses. Follow OSHA guidelines. Slip resistance mayvary with surface conditions from debris that accumulates, weather, footwear and roof pitch. Failure to use proper safety gear can result in serious injury. Depending on roof pitch and surface conditions, blocking may be required to support materials on the roof and is good safety practice. Remember to seal the nail holes after removing blocking. InterWrapO Roofing Products Division Charleston, SC - Vancouver, BC 9 Mission, BC * Montr6al, OC q MEMBERWeb: www.InterWrap.com/roofing I E-mail: info@interwrap.com Toll Free: 888 713 7663 1 Tel: 778 945 2888 Florida Buildino, Code OnlineZD Pac,e I of 2 BCIS Home Log in User Registration Hot Topics Submit Surcharge Stats & Fa cts Publications FBC Staff BCIS Site Map Links Search d b V..".Product ApprovalComm0prUSER: Public User Product Approval Menu > Product or Application Search > Application Lis > Application Detail 21=1 1,11ol-2. FL # FL16994-RS Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Southeastern Metals Mfg. Co. 11801 Industry Drive Jacksonville, FL 32218 904) 696-4682 jhkelsey@semetals.com Jeremy Kelsey jhkelsey@semetaIs.com- Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer E-1 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/20/2020 Validated By Locke Bowden Validation Checklist - Hardcopy Received Certificate of Independence FL16994 R5 COI SEM14001.5a 2017 FBC Eval Report Off-Ridcle Ven final.pd Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method 1503.5 1709.2 Method 2 Option B https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDqvBwYu9TrZN... 2/6/2018 Florida Building Code Online Page 2 of 2 Date Submitted 09/26/2017 Date Validated 10/10/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 16994.1 Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL16994 R5 II SEM14001.5a 2017 FBC Eval Report Off - Ridoe Vent final.lpdApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-18 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL16994 R5 AE SEM14001.5a 2017 FBC val Report Off - Ridge Vent final.l)df Created by Independent Third Party: Yes 16994.2 Tile Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with clay or concrete tile Limits of Use Installation Instructions Approved for use in HVHZ: No FL16994 R5 11 SEM14001.5b 2017 FBC Eval Report Tile Roof Vent final.pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-9 Created by Independent Third Party: Yes Other: See Evaluation Report for limits of use. Evaluation Reports FL16994 R5 AE SEM14001.5b 2017 FBC Eva[ Report Til Roof Vent final;pdf - -- - -- Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone 850-487-182 The State of Florida is an AA/EEO employer. Copyriaht 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487. 1395. -Pursuant to Sect ion 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can >e made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M ON 9Rd 0 I 'ecu6_ 14_1 11 "KNEIP", 1R W, https://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wGEVXQvADqvBwYu9TrZN... 2/6/2018 Certificate of Authorization No. 29824REEK17520EdinburghDr Tampa, FL 33647 813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6 TH EDITION (2017) Manufacturer: Southeastern Metals Manufacturing Co., Inc. (SEMCO) Issued October 10, 2017 11801 Industry Drive Jacksonville, FIL 32218 800) 874-0335 http://www.semetals.com Manufacturing Plant: Jacksonville, FL Quality Assurance: UL LLC (QUA1743) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1503.5, 1709.2 Properties: Roof Ventilation REFERENCES Report No. Standard Yea r- PRI Construction Materials Technologies (TST5878) SEM-029-02-01 ASTM E 330 2014 PRI Construction Materials Technologies (TST5878) SEM-031-02-01 ASTM E 330 2014 Zachary R. Priest, P.E. (CREEK Technical Services) SEM14003 Calculations 2014 PRODUCT DESCRIPTION Off Ridge Vent: Minimum 26 ga. ASTM A792 or ASTM A653 CS Type B steel-, Shall conform with FBC Section 1503.2 Maximum dimensions of the vent are 24-inch wide x 102-inch long x 4.25-inch high. Vent is available in nominal 4-ft, 6-ft and 8-ft sizes. SEM14001.5a FL16994-R5 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I -A. A Be TECHNICAL SERVICES, LLC PRODUCT APPLICATION Southeastern Metals Manufacturing Co., Inc. Off Ridge Vent Deck Type: Minimum 7/16-inch APA span rated OSB sheathing or 15/32-inch APA span rated plywood sheathing for new and existing roof deck (Deck shall be designed by others in accordance with FBC requirements). Roof slope: Minimum 2:12 Installation Height: Maximum 33-ft Roof Cut -Out.- 2.5-inch wide x 42-inch opening for the nominal 4-ft vent 2.5-inch wide x 66-inch opening for the nominal 6-ft vent 2.5-inch wide x 90-inch opening for the nominal 8-ft vent Attachment Method: Cut-out opening as prescribed above into the sheathing located a minimum 6-inch off the ridge. For a single vent, install the vent as close to the center of the roof length as possible. Multiple vents should be evenly spaced along the roof length. Remove interfering shingle nails around the perimeter of the opening and any debris prior to placing vent. Apply ASTM D 4586 or ASTIM D 3409, Type I roofing cement/mastic to the underside of the perimeter flange to continuously surround and seal the flange. Position the vent over the opening in the roof -sheath ing. "Slide the top and side flanges of the vent underneath the shingles and allow the bottom flange to lie on top of the shingles. Attach the vent with #9 x min. 1.5-inch HWH screws with 0.5- inch sealing washers or min. 12 ga. x 1-1/4-inch ring shank nails with min. 3/8-inch diameter heads having sufficient length to penetrate through the sheathing a minimum of 3/8-inch. The fasteners shall be located 1-inch from the edge of the flange and 5.5- inches o.c. along all four sides of the vent. All loosened shingles shall be adhered down with roof cement/mastic. When nails are used to attach the vent, all penetrations through the vent flange shall be sealed using ASTM D 4586 or ASTM D 3409, Type I roofing cement/mastic. Allowable Roof Coverings: Asphalt shingles Maximum Design -13.5 psf for 4-ft and 6-ft vents Pressure -18 psf for 8-ft vent Pressures calculated using 2:1 margin of safety per 1504.9 SEM14001.5a FL16994-R5 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Southeastern Metals Manufacturing Co., Inc. CREEK Off Ridge Vent TECHNICAL SERVICES, LLC LIMITATIONS 1 ) Fire Classification is outside the scope of this evaluation. 2) This report is not for use in the HVHZ. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) SEMCO vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 6) Installation of the roof assembly is outside the scope of this evaluation. 7) SEIVICO vents are intended to provide passive ventilation for an enclosed attic in residential construction applications 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. R 01 E N 2017.10.10 No 74021 10:29:43Ih---Z 04'00' STATE OF 0 oo. --'\ 0 R Zachary R. Priest, P.E. Florida Registration No. 74021ONM-_- Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will -acquire, a financial interest in any other entity involved in -the approval process of the product. END OF REPORT SEM14001.5a FL16994-R5 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. M-IAMI-DADE COUNTY MIAMI- PRODUCT CONTROL SECTIONa11805SW26Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) N%,,,i,w.niiamidade.2o%!/econoniN! Southeastern Metals Manufacturing Company, Inc. 11801 Industry Drive Jacksonville, FL 32218 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The docurnentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including.the High Velocity Hurricane Zone of the Florida Building Code. Z" DESCRIPTION: Weather Vent LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any sectionC, of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 08-042' ).0 1 consists of pages I through 3. The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 13-0814.08 Expiration Date: 04/15/19 Approval Date: 01/23/14 Page I of 32 ROOFING ASSEMBLY APPROVAL Category: Roofingt5 Sub -Category: Ventilation Material: Steel Minimum Slope: 2:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT: Manufactured bv Dimensions Test Product Applicant Specifications Description Weather Vent Vent: 4-1/2"x 19" x 46" TAS 100 Galvanized metal roof vent Deck Flange: 24" x 52" Thickness: 0.0217 inch. MANUFACTURING LOCATION 1. Jacksonville, FL EVIDENCE SUBMITTED Test A2enev Test Identifier Test Name/Report Date PRI Asphalt Technologies, Inc. TAS 100 SEM-002-02-01 08/14/03ZD ICC-ES AC 13 2 SEM-027-02-01 01/07/14 APPROVED APPLICATIONS: Deck Type: Wood Deck Description: "/32" or greater plywood or wood plank System Type A: Mechanical attachment of vent for shingle roofs Cutout: Mark a 31/2" x 46" opening centered between layout lines and aligned minimum 6 inches from the ridge. Set blade to thickness of sheathing and cut opening. Brush away sawdust and debris. Installation: Vents should be evenly spaced on the rear slope of the roof. Center vent in opening and set it in a 1/8" thick of an approved ASTM D 4586 asphalt roofingz' cement. Secure vent to the roof deck with 1-1/4" galvanized ring shank roofing nails spaced approx. 8" o.c. and I" from the outside edge of the flange. Use a minimum of 18 nails per vent. Seal all nails and vent flange with an approved ASTM D 4586 roofing cement. (See drawings herein). Net Free Area: 99 square inches. NOA No.: 13-0814.08 Expiration Date: 04/15/19 Approval Date: 01/23/14 Paue 2 of 3 LIMITATIONS: 1. Refer to applicable building code for required ventilation. 2. Weather Vent shall comply with the manufacturer's current published application instructions and the requirements set forth in the applicable building code. 3. This acceptance is for installations over asphaltic shingle roofs only. 4. Weather Vent shall not be installed on roof mean hei-hts greater than 33 feet. C 5. All products listed herein shall have a quality assurance audit in accordance with the Florida BuildingZD Code and Rule 9N-3 of the Florida Administrative Code. 6. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or loclyo, city, state, and following statement: "Miami -Dade County ProductID Control Approved" or the Miami -Dade County Product Control Seal as shown below: DRAWINGS 0 0 ROOF FLANGE NAIL PLACEMENT a 0 0 END OF THIS ACCEPTANCE NOA No.: 13-0814.08AMMIWAM =1D, ! MDE CEO UMN Expiration Date: 04/15/19 Approval Date: 01/23/14 Page 3 of 3 Grant Maloy, Clerk Of The Circuit Court & Comptroller Seminole County, FL Inst #2019009816 Book:9289 Page:778; (1 PAGES) RCD: 1/28/2019 3:37:19 PM REC FEE $10.00 THIS INSTRUMENT PREPARED BY: Name: Ali Suarez Address: 5200 Vineland Road Su-lte 2N Orlando, Florida 32811 NOTICE OF COMMENICEIRMAIENT Permit Number. 130 M-9151SI Parcel ID Number; 17-20-31-502-0000-1970 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided In this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address If available) Lot 197 Wyndham Preserve Plat Book 81 / Pages 93-102 : 3951 Night Heron Dr, Sanford, FL 32773 GENERAL DESCRIPTION OF IMPROVEMENT: Construction of a new single family residence OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: Park Square Enterprises LLC 5200 Vineland Rd Suite 200 Orlando FL 32811 Interestin pro, y: Fee Simplepert_ 5-7 Fee Simple Title Holder (if other than owner listed above) AAA -- CONTRACTOR: Name Park Square Homes Phone Number 407-529-3000 Address: 5200 Vineland Road Suite 200 Orlando, Florida 32811 SURETY (if applicable, a copy of the payment bond is attached): Name. N/A N/A 6. LENDER: Name. Fifth Third Bank Address: 5050 Kingsley Dr. MD: 1 MOC3J Cincinnati, OH 45227 Phone Number. Amount of Bond: N/A 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(l)(a)7., Florida Statutes. Phone Number 8. In addition, Owner designates to receive a copy of the Lienor's Notice as provided In Section 713.13(l)(b), Florida Statutes. Phone number. 9. Expiration Date of Notice of Commencement (The expiration is I year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. ILA 16 st Owner's or Lessee's Partner/Manager) Vishaal Gupta, Executive Vice President Print Name MW Provide Signatory's Title/Offics) State of County of M=e, The foregoing Instru t nowledged before me this ' J dayof::anua .2019anwasack -- q by -71SVA0,(3J 6 0 Ff-AC, 1— Who Is personally known to me Name of person making stiltement who has produced Identification El type of identification produced: CORINNE M DONOGHUE NotafVitt& - State of Florid, Commission#GG170872 My Comm. Expires Feb 8,202,: 1 '! - UNIVERSAL UESProjectNo: 0110.1700817.0000 Workorder No: 9433040-1 1r.ffVW11V1&1&ffVL1 r%epUlL LJOLUm Consultants In: Geotechnical Engineering - Environmental Sciences Geophysical Services * Construction Materials Testing - Threshold inspection Building Inspection - Plan Review - Building Code Administration (SIR 10"0 0 oqsl'—C7L 3532 Maggie Blvd, Orlando, 32.811 - P: 407.423.0604 - F: 407.423.3106 In -Place Densily Test Rep Client: Park Square Homes UESTlechnician: DiJon Davis 5200 Vineland Road Suite 200 ZY, 02/05/2019T7ateTested: Orlando, FL 32811 Ll Project: Wyndham Preserve, House Lot-T-0sting East Lake Mary Boulevard & Brisson Avenue South, Sanford, Seminole County, FL 32773 Area Tested:.. Lot 197-3951 Niqht Heron Dr Material: Native Reference Datum: 0 = Bottom of Footing Tvt)e,of Test Field: ASTM D-2937 Drive Cylinder Method Laboratory: ASTM D1557 Modified Proctor The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. Test No. Location of Test Range Waximum:)ptimum Density pef) Moisture Field Dry Density pcf) Field Moisture Soil Compaction W Native Depth inch) Pass or Fail I North Proposed footing 0-1 ft 106.8 10.6 103.2 6.7 97 N/A Pas! 2 East Proposed footing 1-2 ft 106.8 10.6 102.1 7.4 96 NIA Pas: 3 West Proposed footing 1-2 ft 106.8 10.6 105.2 6.9 99 N/A Pas! 4 NW corner of pad(TOF) 1-2 ft 106.8 10.6 107.8 8.2 101 N/A Pas 5 SE corner of pad(TOF) 2-3 ft 106.8 10.6 106.1 7.8 99 N/A Pas! Remarks: At the time of testing, the footer was not excavated. So i dug down to the proposed footing and started testing there. r- . -"#".i -4-N- #-I 1^;. 0%. 0,,k1;, -4--h- 1) -_# _ _h-;##-4 - -4 I f )_ 6 - 06) 51 Ni , , 4 &-on Dr DYSCTIPTION AS FURNISHED: Lot 197, WYNDHAM PRESEPVE, as recorded in Plot Book 81, Pcc,)es 93 thiouoh 102 of the Public Records of Seminole County, Florida. Fi(iUNDARI FORICERTIFIED TO: Park Square Enterprises, LLC (a Delaware Corporation); Winderweedle, Haines, Word & Woobinon, PA; Attorneys' Title Insurance Fund; Bonk of America LOT 203 LOT 202 LOT 201 S 00*1657" E 60. 00' Yv_ LOT 19' 24.80' 24.80' 1 1 32. 13' 15.00, I 15.00' FORMBOARD Cr) FOUNDATION C TOF=TOP OF LOT 195 01:, LOT 196 ko FORM FORM AVERAGE 23.35' Lllpll 15.00' 0 15.00' 25.20' 25.20' 1 10 , UT7L. ESh S 00'16'57" E (B.S.) 60. 00' 5;'F81,(XS AS(,FURNtSHED HERON' DRIVL' F ?ONT = 25' NIGHT 0R_ R - 2 ' 50' PRIVATE R/W) S; 5 ' (49' LOT) 715' (60 : LOT) 0' (7.5 LOT) SDE ;TRFET = 25' (60' & 75' LOT) 15- (40' LOT) 2!;' FRONT' SETBACK CAN BE REDUCED T,n 20' ON CERTAIN LOTS. NO MORE THAN 1) IN SUCCESSION AT 20' AND .4 MINIMUM Of (2) IN SUCCESSION AT 25- PROPOS.71) = FWSHED SPOT GRADE ELEVATIONS PEj: OF VNAGE PLANS PROPOSED DRAINAGE FLOW ' 0LO G90ING TYPE A PR)POSED F.F. PER PLANS = 23.1' USEXHEYER -SCOTT ASSOC., INC. IAND SUR V ORS 5400 E. COLONIAL DR. ORLANDO, FL. 328o7 (407)-277-3232 FAX P P.0 POINT ON L- ATFBM TYP. T- WES. Ba pn. P. PUIXT OF REVERSE cwwmmP= KINT 7 1. THE VNDDRS NED DOES HEREBY CERWY MAT MM SURVFY MDE; ME STMIDARDS OF PWCrXE SET FORM R, OF PROFESSVM SURWYORS AND W-M IN CHAPTER SJ-J:''OA AOUIN SMATW CDDE PVRS I ECWN 1 2027, OR(M ST-ES C TE IENT RAm S j V2, 1. ".0 45% c. RE.1— , 2. M 0=&, NM S RVyDY; SWATURE AND MGIRAL MJSED SEAL. THIS SURVEY WP OR OCNES ME N11 1AUr. 3 MIS SURVEY WAS PREPMED FROA4 MLE INFORWDON FUFNISHED TO ME SURVEYOR. MERE Y BE OMM RESIUrONS D. _. , _' W U M=M OR EASEWOWS MAr AFFECT PROPERTY. TED a SS nMETW1SE SHORN, ND WDERCROUND 1UPROYMENM h4W BEEN t CF.T-- IF. "M 'L FDR BENEFT DF __ CEN t- SHCV. NOT BE .ED 61 "", CMES ENTTY. VAY TCREC0HS CT-1v?y-SJ, E- .11T tt 7. 8&. ARE BASED ASS UED NVU AND ON ME AS sAs (a..) DONS fF , ARE BASED ON NA GOOOM DAMM Y 1929, UN OTHERMSE TED L11 CL5-. C I L— 11 9, CV ATE 01 AVMGRI UCH 011, c", ETE 20 P P, ITP, CEJMFrED BY. FA_T_E_ 1 7. R No. 117 PLOT PLAN 11-05--2018 7360-18 MIA FORMECARD FOUNDATIONIFLEVS. 02 -0 1 -20 1!1 902-19 M. NORTH I H.'S BUILDING%PROPERTY DOES NOT LIE WITHIN THt7 ESTAW5110 100 YEAR FLOOD PLANE AS PER 'FIRM' 11 L 4774 W !;.IT, L "I 2511E 1XI MAP I 12117CO090 F (09-28-07)