Loading...
HomeMy WebLinkAbout3917 Saltmarsh Lp 18-1392 New SFHI ]b G. Job Address: 3917 Saltmarsh Loop, Sanford CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: 18- 13q)- Documented Construction Value: S fMRE 'ZB(652-S."o Wyndham Preserve lot 173) Historic District: Yes 0 NoEl Parcel ID: 17-20-31-502-0000-1730 Residential 0 CommercialEl Type of Work: New 0 Addition El Alteration El Repair El Demo El Change of Use El MoveEl Description of Work: Construction of new single family residence Plan Review Contact Person: Michelle Parkison Title: Permitting Manager Phone: 407-529-3135 Fax: Name Street: City, State Zip: Name Street: Email: mparkisone-parksquarehomes.com Property Owner Information Phone: Resident of property? : No Contractor Information Park Square Homes/ Vishaal Gupta Phone: 407-529-3000 5200 Vineland Rd Suite 200 Fax: 407-529-3001 City, State Zip: Orlando, FL 32811 State License No.: CRC1330351 Arch. / MJS Home Designs Architect/Engineer Information Name: Eng. / Don Bolden Eng. Phone: Arch./ 250 N. Wymore Rd. Suite B \A/inter Park FL 32789 Street: Enq./ PO Box 530783, Deba[y FL 32753 Fax: City, St, Zip: Bonding Company: Address: E-mail: Arch. 407-629-6711 Encl. 386-668-7606 Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, beaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5 1h Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. d P Aak '3- g-ature of ow&/A-gent ' / - Date 1 Ash>,CA G Print Owner/Agent s N e Sign&e ofNotary-St—ate ofl`lorid'ai, Date MICHELLE PARKISON State of FloridaNotaryPublic commission # GG 157861 y Comm. Expires Nov 5, 2021 Bonded through National Notary Assn, Owner/Agent is I RIM" Produced ID Type of ID geSignatur; of Contractor 61 Date G Print ContF a6®ra Ks N ame MICHELLE PARKISON Notary Public - State of Flo ida Commission # GG 157861 My Comm. Expires Nov 5, 2021 Bonded through National Notary Assn Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Buildingz Electricaig Mechanicala Plurnbinggj Gas[] RoofF] Construction Type: F2 Occupancy Use: Flood Zone: K—t-g' Total Sq Ft of Bldg: Min. Occupancy Load: tA # of Stories: New Construction: Electric - # of Amps Zm) Plumbing - # of Fixtures 18 Fire Sprinkler Permit: Yes n No Y # of Heads APPROVALS: ZONING: 114 1 16 UTILITIES: I COMMENTS: ENGINEERING: "T(— 19 FIRE: Ok to construct single family home with setbacks and impervious area shown on plan. '53.S % 'ime. 2-o-i i, so c (-,e ni. - A , Cr L- Fire Alarm Permit: Yes [] No& WASTE WATER: BUILDING:- 9r,. !". I 1- (9 Revised: June 30, 2015 Permit Application J4 M CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: I B— 13q)— - Documented Construction Value: $ 150,537.00 Job Address: 3917 Saltmarsh Loop, Sanford (Wyndham Preserve lot 173) Historic District: Yes D No Parcel ID: 17-20-31-502-0000-1730 Residential 15d Commercial Type of Work: New 0 AdditionEl AlterationEl RepairEl DemoEl Change of Use 11 Move De . scription of Work: Construction of new Single family residence Plan Review C6iiitact ]Person:' Michelle Parkison Title: Permitting Manager Phone: 407-529-3135 Fax: Email: mparkison(cb-parksguarehomes.com Property Owner Information Name Street: City, State Zip: Phone: Resident of property? : No Contractor Information Name Park Square Homes/ Vishaal Gupta Phone: -.407-529-3000 Street: 5200 Vineland Rd Suite 200 Fax: 407-529-3001 City, State Zip: Orlando, FL 32811 State License No.: CRC1330351 Arch. / MJS Home Designs Architect/En ginee'r Information Arch. 1 407-629-6711 Name: Eng. / Don Bolden Eng. Phone: Eng. 386-668-7606 Arch./ 250 N. \Afymore Rd. Suite B Winter Park FL 32789 Street: Encl./ PO Box 530783, Deba[y FL 32753 - Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING'TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST I BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby.made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, -signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30,2015 Pennit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Llw " 3. Signature of`0w;i;A-gent Date Print Owner/Agent's N e 7 Nb _ sl gn&e ofNotary-Sgte ofFlorida Date MICHELLE PARKISON State of FloridaNotaryPublic Commission # GG 1578614", J rn. Expires Nov 5, 2021MyComImpBondedthroughNationalNotaryAssn, Owner/Agent isl2i 0'?MTff19 MOT Produced ID TypeofID Signatur; of Contractor& Date Vi,ha. G,d-_V_ Print ConVaTo—rTA`g-ents Name of 01 pt . Y .. Pi MICHELLE PARKISON p', Notary Public - State of Florida Commission # GG 157861 My Comm. Expires Nov 5, 2021 Bonded through National Notary Assn. Contractor/Agent is Personally Known to Me or Produced DD — Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building[] ElectricalE] MechanicalF] Plumbing[] GasE] Roof F] Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: YesF] NoF] # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: Flood Zone: - of Stories: Plumbing - # of Fixtures Fire Alarm Permit: YesE] NoF] WASTE WATER: BUILDING: Revised: June 30,2015 Permit Application City of Sanford Planning and Development Services Engineering — Floodplain ManagementMi1877S— Flood Zone Determination Request Form Name: Michelle Parkison Firm: Park Square Homes Address: 5200 Vineland Road, Suite 200 City: Orlando State: FL Zip Code: 32811 Phone: 407-529-3135 Fax: Email: mparkisonCcDparksquarehomes.com Property Address: 3917 Saltmarsh Loop Property Owner: Park Square Enterprises, LLC Parcel identification Number: 17-20-31-502-0000-1730 Phone Number: 407-529-3000 Email: The reason for the flood plain de termination is: FE-1 New structure 0 Existing Structure (pre-2007 FIRM adoption) F-1 Expansion/Addition E] Existing Structure (post 2007 FIRM adoption) Pre 2007 FIRM adoption = finished floor elevation 12" above BFE Post 2007 FIRM adoption finished floor elevation 24" above BFE (Ordinance 4360) Flood Zone: X Base Flood Elevation: N/A Datum: N/A FIRM Panel Number: 120294 0090 F Map Date: Sept- 28, 2007 The referenced Flood Insurance Rate Map indicates the following: F-1 The parcel is in the:Elfloodplain Ofloodway F-1 A portion of the parcel is in the: 0 floodplain 0 floodway FE-1 The parcel is not in the: FE-1 floodplain F-1 f loodway The structure is in the: 0 floodplain El floodway The structure is not in the: F-I floodplain F-I floodway If the subject property is determined to be flood zone 'A', the best available information used to determine the base flood elevation is: BP# 18-1392 Reviewed by: Michael Cash, CFM bate: March 22, 2018 I I P j Application for Paved Driveway, Sidewalk or Walkway Including Right -of -Way Use & VvOR 11n)." I A 0; k4. -F IAI N —1877—'-4 Call atclp 111d 11 U -V - city www.sanfordfl.gov Department of Planning & Development Services 300 North Park Avenue, Sanford, Florida 32771 Phone: 407.688.5140 Fax: 407.688.5141 This permit authorizes work to be done on the subject property or in the City of Sanford's right-of-way in accordance with the City's the this The is for drivewayregulationsandattachedconstructionplansapprovedaspartofpermit. permit required or sidewalk construction over 100 square feet of concrete or other material on the subject parcel and / or any construction of a driveway, walkway or landscape improvements within the city right-of-way. It does not approve any work within any other jurisdiction's right-of-way. All requested information below as well as a current survey, site plan or plat clearly identifying the Know whays below. size and location of the existing right—of-way and use shall be provided or application could be delayed. Call before you dig. Project Location/Address: 301 1--\ Cso.Arfxmrs- cc,01,; cxd 2. Proposed Activity: FX_1 Driveway El Walkway F-] Other: 3. Schedule of Work: 4. Brief Description of Work Start Date Completion Date Construction of new driveway for new single family residence This application is shubmitte Y_ 1 Property Owner Signature: — , Address: 5200 Vineland Rd S Phone: (407) 529-3135 R rlando,FL 32811 Print Name: Vishaal Gupta ElEmergency Repairs Email: mparkison@parksquarehomes.com Date: 3.1ro .18 Maintenance Responsibilitieslindemnification The Requestor, and his successors and assigns, shall be responsible for perpetual maintenance of the improvement installed under this Agreement. This shall include maintenance of the improvement and unpaved portion of right-of-way adjacent thereto. Requestor may, with written City authorization, remove said installation/improvement fully restoring the right-of-way to its previous condition. In the event that any future construction of roadways, utilities, stormwater facilities, or any general maintenance activities by the City becomes in conflict with the above permitted activity, the permittee shall remove, relocate and/or repair as necessary at no cost to the City of Sanford insofar as such facilities are in the public right-of-way. If the Requestor does not continuously maintain the improvement and area in accordance with previously stated criteria, or completely restore the right-of-way to its previous condition, the City shall, after appropriate notice, restore the area to its previous condition at the Requestor's expense and, if necessary, file a lien on the Requestor's property to recover costs of restoration. To the fullest extent permitted by law, Requestor agrees to defend, indemnify, and hold harmless the City, its councilpersons: agents, servants, or employ- ees (appointed, elected, or hired) from and against any and all liabilities, claims: penalties, demands, suits, judgments, losses, expenses, damages (direct, indirect or consequential), or injury of any nature whatsoever to person or property, and the costs and expenses incident thereto (including costs of defense, settlement, and reasonable attorney's fees up to and including an appeal), resulting in any fashion from or arising directly or indirectly out of or connected with the use of the City's right-of-way. I have read and understand Signature: This p1g. Please call 407 Pre -pour Inspection by: Application No: Reviewed: Public Works Utilities Approved: Engineering Site Inspected by: Special Permit Conditions: statement and by signing this application I agree to its terms. Date: 5-195-18 11 be posted on the site during construction. 24 hours in advance to schedule a pre -pour inspection. Date: Official Use Only Fee: Date: Date: Date: Date: 3_Z-Z_Z010_ Date: November 2015 1 ROW Use Driveway.pdf LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: ')- 115 - I hereby name and appoint: an agent of-. David Mercer Park Siquare Homes Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): El The specific permit and application for work located at: Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: Vishaal Gupta State License Number: CRC1330351 Signature of License Holder: STATE OF FLORIDA COUNTY OF Orange The foregoing instrument was acknowledged before me this 15 day of ry"q-r&- , 20.Wj_&, by Vishaal Gupta who is D(personally known to me or ii who has produced identification and who did (did not) take a a Sig ature Notary Sea]) F MICHELLE PARKISON Notary Public — State of Florida Commission # GG 157861 MY Comm. Expires Nov 5, 20210,- 0 , Bonded through National Notary Assn. Rev. 08.12) Y-\,\ - - C)C'Q Q Print or type name Notary Public - State of Vk T'4 Commission No. Ccq v5 -I e) co I My Commission Expires: I I - r:) - QQD-j as REQUIRED INSPECTION SEQUENCE PARK SQUARE HOMES SFR-DETACHED P..I-M;f it BuiLDING PERMIT Min Max Inspection Description 10 Form board / Foundation Survey 10 Slab / Mono Slab Prepour Lintel / Tie Beam / Fill Down Cell 30 Sheathing — Walls 30 Sheathing — Roof 40 Roof Dry In 50 Frame 60 Insulation Rough In 70 Drywall / Sheetrock 40 70 Lath Inspection 50 Final Roof 50 1000 Final Stucco / Siding 80 1000 Insulation Final 1000 Final Single Family Residence AfItirs-ce- gg? ;-,,.ggEf64o Min Max Inspection Description lo Underground Electric 10 Footer / Slab Steel Bond 20 30 Temporary Underground Power (TUG) 30. Electric Rough 1000 Electric Final M ;, R 57 Inspection DescriptionMinMax 10 Plumbing Underground 20 Plumbing Tubset 10 1000 Plumbing Sewer 1000 Plumbing Final IN Min Max Inspection Description 10 Mechanical Rough 1000 Mechanical Final R,EVISED: June 2014 CITYPIF'SANFORD BUILDING & FIRE. PREVENTION PERMIT APPLICATION Application No Documented Construction Value:$ Job,Address: 39 1 Jq. _[m qj,, G, Historic District Yes' No Residential CommercialParcel'ID: Type of Work: New RepairLNAdditionElAlterationn DemoEl Change of,Us'e El Move 0 I Description of Work: 0,_.J Ui`JJ S .( Plan Review Contact Person: Phone - Fat: Email: Property QW,her, Lnfotrri,ition Name Phone - Street: Resident of property? City, Sta'te,Zip Cohteact6r-Ihf matiori Pho 411 07, Pat:" Lgteeet4 S, 11 o.: C:F(Jql) ity, State Zip State Lice se N Arch it6dt/E ng ineer Informalfflon Name:, Phone,: street: Fax: city, St, Zip: E-mail: Bond*g Company: I M Address,: Mortgage Lende ' r: Add ress'! - WARNING TO OWNER:. YOUR FAILURE TO RECORDA NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO, YOUR PROPERTY, A, NOTICE OF CQMMKNCEM N USTBE RECORDED AND POSTED 0 , N THE JOB SITE BEFORE THE FIRST INSPECTION. IF YO ' U INTEND TO OBTAIN F INANCING, CONSULT WITH YOURLENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made,to obtain a permit toAo thework and installations as indicated. I certify that,no work or in tallation. has commenced prior to the issuance I of a bermit an I dthat I all I work,will be performed,to meet standa dsof all1aws re ulati ng construction in this jurisdiction. I understand th'at a separate perm I it.mus t be secured for electrical work, plumbing, signs, Wells, pools, furnaces, boilers, heaters,11anks, and air conditionersi etc. FBC 105.3 Shall be inscribed with-thc dateof application and the code.in effect as of that da,tc:,514 Edition (2014) Florida Buildin, Code Revised: J'uRc 30,2015 Perm itApplication F— — — i' ' bJTOTICRInaddifiontotherequirementsofthispermit, there may be additional restrict-ons.'applicable,to this property that may e found ifi the public records of this county, and there ma I lbe Add itional 'permits required from other governmental cIntiti&s, such as waterY management districts, state agencies, or federal, agencies. Acceptance of permit is verification,th t I Will.n6tif y of the requi eaient s,bfflorida Lien, Law, FS 711ythepwnerofthepropero The Citv of Sanford requires payment, of a plan review fee at the time of permitsubmittal. AcopY of the e,xecb1t16d contract is required in I order to calcu I late a pla I n re, . view ch I arge and. will be considered, the estilmated.construction value of the job at1the time o,f'submittal. The actual con'str t,ICC VAluatibn.Table in effect at the time the permit is issued, inuctionvaluewillbefiguredbasedon.the curren. accordance With local or , dinance. Should calculated charges figured offthd eiecUted contract exceed the actual construction value, credit Will be appliled,to your permit fees when ihe,permit is issued. OWNPR'S AFFIDAVIT:1 certify that all of the foregoing information is: accurateland that all work will be done, in compliance with all Appl . icab I lelawsr gulating construction and zoning. 7 11 SignaiureofOwncir/Ag6nt Oat. §ig _a ure C, , ,on to/Agent Date cv— Li V1 j CA Print Qwncr/Ageml'., Name, Sighati reo'f Not* -State of Florida Date 4FF120855 Owiler/Ac=tis—. 'Personally'.Know.n,to M.e of - COPtrdetor/AgePtis Personally P oiddc d 0 7-ype 6 f . 10 Ptodudedj1Q_ T pe,olftD— BELOW IS FOR OFFICE USE ONLY PermitsR quited: Buildi , ngF] 'ElectricailEl Mechanica]Fj Plumbing[I Qqsn Roof [I Construction. Type: Occupancy Use: Flood.Zone: Total Sq Ft of Bldg: Min. Occupancy Load', of Stories: New Construction,:, Electric -,9, of Amps Plumbi,ng - A of Fixtures, Fire Sprinkler Permit: Yes n N6F! #'of Head's Fire Marm Permit: Yes No F1 APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: COMMENTS: R6,ised: June,30,2015 FIRE - BUILDING: Permit Application L— - -- - ---- - --- —. .. - 7 7 job Address: Parcel.TD- l_ T-, pe of W.ork-:: N.ew Descriotion ofW*ork: CITY'OF SANFORD BUILDING& FIRE PREVENTION PERMIT APPLICATION Applicatioln NO: Docunle.rited Constructian N"'alue: S C7 /_nd). - Historic District: Yes F1 No 7'-' jA Irl, 'hailll Residentiall] Comnilef-cilall] Additionn Alferatio"110 Repair 1:1 D rno 0 Change of U e _Nlove ElUsE] c— WAS M Plan Review Contact Person: Title: Phone: Fax: Eniai . 1-. Properly Owner Information N'arne Phone Street: Resid'entlof property" - City, State Zip: contractoir Inforniation A P ho n e: Street, Fax: i C C tv. St"ate Zip:, i j I St"afe License -N o.: Architect/Engineer [nform atl'on Narne: P Il on e: Street: Fav City. St., Zip: E-nia,il: Bondin 3, Conlipariv: 10 I-'(T',l Qe L e n (I L r: d (I 17eSS: Address: NVARNT'NG TO ONN"NER: YOURFAILURETO RECORD A, NOTICE OF COMMP,(JAIENT MAY r'u-_'SULT.lN_' vOUR P.-kYIN*G TWICE FOR IMPROVEMENTS TQ 7i"'QUR PIR ' O'PERI'Y. A NOTICE OF I COMNIENCEMEN-F NIUS1 BE RECORDED AND ON 71-HE JOB SITE BEFORLE THE 171!'SI- IF YOU INTE\D TO OSTMN F[__N;A-'N'-ClNG. CONSUL-F WITH YOUR-LENF)Tll OR ANN Al-l'ORNEY BEFORE 'R'F(',OR0lV'. \01-ICE OFY0UR C"10AIMENCEM E",,T. 10 id till.11i flo, v-o-' 0:'i'- th f !-i;' diz, t-o; ;' a i'l i e ol pL—m-J 1 an i hl i a! I v, 6_ %vi' 1 b folml_l L C" rn-c t sil- nd an-li; o F- 11, 1 a v, u :l - i j, c c,:- o is..;ua C I)el-Illit HILBtund_lrst'.i'rd th-.it a separate be secured f6r cle trical \%ork, plupilhin'z! N el!st pools Furnaces, boilers. tanks, and air conditioners, etc. FBC I f)-;.3 Shall be inscribed %% idli (lic- of "'Ipplicatiorintid ih ciodc in s ofth.'irdiue: ;t' Ediion (20141) Flfwicl-1 Buildin' Code In to th -erricnts of this perrnit there' i av b.c addicional to this pr P r;y that niak. I N'() T 1 C E . 'addidi;,n t requir 10 r,-cpvds ofth s countv, and there mi'VA)c additronal Permits r,,qLlircd Tn o he r covenim-,rital eft", ni, n- _,emcnt districts, state a,encies', or federal ac encics. Acce,puanec o pernaii is verification that I will notifv thc,own-r of the Proper-,v Of the requirenients of Florida Li-_ri Laxv7 J.S 7 1 31. Thz Ciw of' Samford rc,quirz-s p.ymont olf,,a j lan az the I I inic o r U a JfP21CO)V Qi'fl C 'CAeCLIted comract is r,.Juire r order to calculate aplan reviv, charm.' and will,be,considered e-liT11,1ILd constru Iion vahiz- of the job at thz tilll.' Of Slibn ittal. Tho act ial consui-il-tiori value will be ficured ba,ed on the cuiTent CC Valuation Tabl- in cff ci at the t h,_- the u e d. i rI accorclan e Viih -local ordinance. Sho uld cal c u I' z-d c har(,- s Fi Lnirr2d c! IT the eXt ed C on trac I e-\c 2"-d th ac ma I co -ion valu_ I, be ap plicd,to yourTo niii ffc,-s when.the,permit k issued. OWNER'S AFFIDAVIT: 1 certifv 01at all of the fore6oinainfo-mation is accura , te and that all Nvoi-k NN.iil be.done in compliaric,e w[th all applicable LaN s, regulatin, construct i o S Da, is P&rsonaily Knovvr! to,,Me Pr Pi'od,.ked [D Tlyp of ID S im PluoCiuced ID Type of ID 74S F, BELIMN O,R OFFICE USE 0- TY Plermits Pke4uired: BUild_Ln T GasR R,,)c,-E] C6nSti.-Lictian Type: Occupancy Use: Flood Zone: To, a I Stl t t of B I (I gy: iMirri. Occupancy Load: 77 0 f S to ri, S N7 Constrtt&ion Ele,ctric - ofAmips Pl,nlbino of Fixture's Fire.Sj)1rinIJ&r Pernnit: YesEl ,7o El of it -acis Fire pern,t': Y e-s F] No t 7-F IAPPROVAL.'-. Z(Y.\.1,.\'G.. J WASTE VNi.-,kT EIR E.\GINEERfNG: F IRE: R U1 L D I-N* G C 0.N I _N I, E ',s'- F S, or 0 !'-, I S 10 N .--) F R K. S Q; J AR \1 r F R P R 1 1.3 E, 1. L City of Sanford Building & Fire Prevention Division 300 N. Park Ave Sanford, FL 32771 To Whom It May Concern: Please be advised that Edmonson Electric has been released from the following permits: 18-0741 - 3924 Night Heron Drive 18-1392 - 3917 Saltmarsh Loop 18-1265 - 3908 Saltmarsh Loop 18-1473 - 3905 Salt,marsh Loop The new contractor is Stra ' da Electric. Please let me know if you need anything else to resolve this matter. I can be reached at 407-529-3163 or tpickerinq@parksquarehomes.com - Thank you for assistance with this matter. Sincerely, T r ia P kering Permitting Coordinator, Park Square Homes flt, 407 529 3 1004.xz-' '03 C.:1 J2 4 0 7 5 2 9. 3 0 00 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Applicatio It No: Documented Construction Value: $.5338.00, Job Address: 3917 Saltmarsh Loop Historic District: YesEl No 0 Parcel ID: 17-20-31-502-0000-1730 Lot 173 Residential R Commercial Type of Work:'New R AdditionD AlterationEl R' eipairEl DemoD Change of.UseEl Move El Description of Work: Install new 3 ton HVAC with duct work Plan Review Contact Person: Paula Bagley Title: Permit Clerk Phone: 407-975-2762 Fax: 407-629-9307 Email: pprr-hitting@onestopcooling.com Property Owner Information Name Park Square Homes Phone: 407-529-3000 Street: 5200 Vineland Rd #200 Resident of property? City, State Zip: Orlando, FL 32811 Contractor Information Name One Stop Cooling & Heating, LLC ' Phone: 407-975-2762 Street: 7225 Sandscove Court Fax: 407-629-0307 City, State Zip: WEnter Park EL 32792r State License, No,.: CAC 032444 Architect/Engineer Information Name: Street: city, S t' Zip: Bondini Company: Address: Phone: Fax: E-mail: Mortgage Lender: Address - WARNING TO OWNER: YO I UR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST I BE RECORDED AND POSTED ON I THE JOB SITE BEFORETHE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT, WITH YOUR LENDER OR AN ATTO"EY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and instailations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all,laws regulating construction in this jurisdiction. I understand that a separate- pertnit inust be secur . ed for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the -date of application and the code in effect as of that date: 514 Edition (2014) Florida Building Code Revised: June 30, 2015 L Permit Application NOT - ICE: In addition to the requirements of this permit, there may be additional restrictions applicable tolhis property that rnay bc. found in the pub-lic,rec-ords. of ihis:county, and,there may..b.e additional permits required from other governmental entities such as water management districts, state agencies,,or federal agencies. Acceptance of permit is verificatioty,ibat I will I notify the"owner of the properlty"of the requirements of Florida Lien Law, FS 311 The City of Sanford requires payment of a plan revicw.fee at the tinic-of permit submittal. A copy of the exectfled contract is required in order to calculate a plan review charge and will be, considered the estimated construction value of the job at the time of submittal. L C Valuati 'n Table in effect at the time the permi , tisissued,inTheactualconstructionvaluewillbe,figured based-pn the cl n-r-'ent IC to accordance with local ordinance. Should calculated charges figtwe'd off the executed contract exceed tile actual construction value, qredit,%vill be applied to your peruiit.'f&s when the permit is issued, OWNER'S AFFIDAVIT: 1,certify that all of the fore oi , ng, information is accurate and that all work will be done in compliance with all applicable laws regulati g cAlstrudir n and zoning. 819118 Signiture of Own6r/Agcnt Date- Sijnaiur of &fitrictor/Aizent. Date Kevin'Stine Print Owner/Agent'sNante Print Qontracto,Mgent's.Narne Signature of Notary -State of Florida Date Signa,ture, o Flof 8097:3 r4 4.4iZA-y P99A KELLY"WEBSTER0 Notary Pubilc,-Itate of 1`106 COM!nlsslo6# FF' 7 ' 8014 OF pr 04 , 2MyP6mm. Expires Apr 4 1020 Known to Me or 'Col let IOwner/Agent is Personally' r Pfoduced,,ID Type of , ID Produced ID Type of ID BELOW IS FOR OFFICE, USE ONLY e P Ul 'ired: Building,[] OectricalE] Mecbanical[] ri its Rpqu lu1mbingFj Gas[] koof[] Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: of Stories: New Construction: Electric,, - ft of Atups Plumbing - # of Fixtures Fire Sor Iinkler Perinit,:. Yes F1 No F] ff of Heads Fire,Alarm Permit: Yes No El APPROVALS: ZONING: UTILITIES WASTE WATER: ENGINEERING: FIRE: WILDING: Ptnni-t Application FIRE INSPECTIONS CITY OF SANFORD 407.562.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Application Number . . . . . 18-00001392 Date 8/09/18 Application pin number . . . 376656 Property Address . . . . . . 3917 SALTMARSH LP Parcel Number . . 17.20.31.502-0000-1730 Application type description NEW SINGLE FAMILY HOME - DETACHED Subdivision Name . . . . . . Property Zoning . . . . . . . PUD Application valuation . . . . 286825 Application desc noc on file Owner Contractor PARK SQUARE PARK SQUARE HOMES CO MICHELL 5200 VINELAND RD SUITE 200 ORLANDO FL 32811 407) 529-3135 (407) S29-3000 Structure Information 000 000 ---------------------- Construction Type . . . . . VB Occupancy Type . . . . . . RESIDENTIAL USE GROUP Flood Zone . . . . . . . . NONE Other struct info . . . . . ELEC - # AMPS 200.00 PLUMBING FIXTURES 18.00 NUMBER OF STORIES 2.00 SQUARE FOOTAGE 2672.00 Permit . . . . . . MECHANICAL - NEW RESIDENTIAL Additional desc . . Phone Access Code 1069616 Permit pin number 1069616 Sub Contractor ONE STOP COOLING & HEATING INC Permit Fee . . . . 110.00 Issue Date . . . . 8/09/18 Valuation . . 5338 Expiration Date . . 2/05/19 Qty Unit Charge Per Extension BASE FEE 110.00 Special Notes and Comments All projects within the City shall use WastePro for debris removal. Please contact WastePro at 407.774.0800. Normal hours for inspections are from 7:30 through 4:30 Monday through Thursday. Please be aware you must contact the Building Official to schedule a Friday or after hours inspection. This is required since not every inspector is licensed to do every type inspection. Communication is the key, so please contact the Building Official if you have any questions at 407.688.5058 or at dave.aldrich@sanfordfl.gov Water impact fee $1343.00 Sewer impact fee $3025.00 Other Fees . . . . . . . . .. 01-APPLCTN FEE -ELECTRIC 25.00 01-APPLCTN FEE -BUILDING 25.00 01-APPLCTN FEE -MECHANIC 25.00 01-APPLCTN FEE -PLUMBING 25.00 01-BLDG PLAN REVIEW 1086.00 01-CHANGE OF CONTRACTOR 35.00 JRD BUILDING PARK AVE rORD, FL 32771 SALE DUPLICATE MID: 9520 Store: 4616 Term: 2903 REF#: 00000015 Batch #: 012 RRN: 822116018670 08/09/18 12:44:20 Invoice #: 181392 CVC: N ns ID: 588221602607737 CODE: 022811 Manual CNP 139.03 CUS 1, Oper: ANTONINIL Type: OC Drawer: IDate: 8/09/18 01 Receipt no: 173763 2018 1392 3917 SALTMARSH LP 3ANFORD, FL 32773 BP BUILDING PERNIT,RECEIPTS 139.03CCCREDITCARD $139.03Totaltendered Total payment *139-03 139 03 FAILURE TO COMPLY WITH MECHANIC'S LEIN LAW CAN RESULT IN THE Transdate: PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS. NOTE: ALL FEES MUST BE PAID.PRIOR TO C.O. BEING ISSUED. NOTE: PLEASE BE ADVISED'ALL PERMITS MUST BE INSPECTED. 8/09/18 Time. 12:43:59 L_ - - ..-I -- I . . - 1. - . - FIRE INSPECTIONS CITY OF SANFORD 407.562.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Page 2 Application Number . . . . . 18-00001392 Date 8/09/18 Application pin number . . . 376656 7 ----------------------------------------------- Other Fees . . . . . . . . . 02-CURB CUT/DRIVE - SIF 40.00 01-FIRE IMP-RS 9-2017 383.81 01-LIBRARY IMPACT FEE 54.00 01-PARKS IMP-RS SINGLE 17 1103.95 01-POLICE IMP-RS 09.1.17 384182 01-BLDd REINSPECTION 35.00 01-SEM,CNTY RD IMPACT FEE 705.00 01-SCHOOL IMPACT FEE 5000.00 WD,IMPACT:SINGLE FAMILY 1343.00 SD IMPACT:SINGLE FAMILY 3025.00 01-BLDG DCA SURCHARGE 37.60 01-BLDG DBPR SURCHARGE 53.43 Fee summary Charged Paid 'Credited Due Permit Fee Total 110.00, .00 .00 110.00 Other Fee Total 13386.61 13357.S8 .00 29.03 Grand Total 13496.61 13357.SS .00 139.03 FAILURE TO COMPLY WITH MECHANIC'S LEIN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS. NOTE: ALL FEES MUST BE PAID PRIOR TO C.O. BEING ISSUED. NOTE: PLEASE BE ADVISED ALL PERMITS MUST BE -INSPECTED. FIRE INSPECTIONS CITY OF SANFORD 407.562.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Page 3 Application Number . . . . . 18-00001392 Date 8/09/18 Property Address . . . . . . 3917 SALTMARSH LP Parcel Number 17.20.31.502-0000-1730 Application description . . . NEW SINGLE FAMILY HOME - DETACHED Subdivision Name . . . . . . Property Zoning . . . . . . . PUD Permit . . . . . . MECHANICAL - NEW RESIDENTIAL Additional desc . . Phone Access Code 1069616 Permit pin number 1069616 Required Inspections Phone Insp Seq Insp# Code Description Initials Date 10 409 MHOl MECHANICAL ROUGH IN 1000 410 MH02 MECHANICAL FINAL DESCRIPTION FURNISHED: Lot 73' WYNDHA/W as recorded in Plot Book B1. Pages g] 762 of the Public Records of Seminole County, F/orido. ILIT IL4N^~^'`~—'-- 0: Park Square Enterprises,LLC /n Delaware Corporation); Vinderwoed|e, Haines, Word & Woodman, PA; Attorneys' Title Insurance Fund; Bonk of America LOT ,63 LOT 162 ` LOT /a/ 000 LU2' 2 3 | r uuo' »«»»' 27.33' 14.7 am . FORMBOARD FOUNDATION TOF=TOP OF FORM cu LOT /,2 o CO eu 96.00' z5.00' 25.00' 1 — — — — —|— — — l /o' un cswr } Bfl) N89040'51 "F 40.D0' FRONT (50' PRIVATt PIN 25' FRONT SETBACK CAN BE REDUCED PLOT PLAN OVJJ TO 20' ON GERTAIN LOTS, NO MORE THAN PLOT PLAN AREA CALCULATIONS NO T A S UR VF. Y OF (2) IN SUCCESSION AT 25' TOTAL LOT AREA 4,400 + SQUARE FEET SQUARE FEET FLATWORK PROPOSED = FINSHED SPOT GRADE ELEVATIONS FLAT VORK ONIOFF LOT TOTAL SQUARE. FEET FOUNDATIONIF'AD- -1,744 1 SQUARE FEE-1 PROPOSED DRAINAGE FLOW FRONT PORCH DECK 62 1 SOUARF*.' FEE LOT GRADING TYPE A SOD 2,0331 130 = 2,163 ± SQUARE FE POOL. DECK OVIDED BY CLIENT NOT FIELD VERIFIED PPOPOSED F.F. PER PLANS = 30.5' *NOTE FRONT SIDFWALK AND STRFCT LOCATION TAKEN FROM PLANS PR .......... PLAI P.G.L. POINT ON LINE NOIES: F1 L TYP, TYPICAL SE CURVATURE I T, DS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF IPENDNI'r PRC. POINT 13F REVER . ' UNDVSIGNEO DO S j HEREBY CERT7FY THAT THIS SURVEY MEETS THE STANDAR TO SECTION 472.027, FLORIDA STAR;E.5 V. IRON ROD C, POINT OF COMMON PRO RS CONCRETE HONUMENT RAIL RADIAL ) W10i 5UR%S-YOR'S SIGNATURE AND ORIGINAL RAISED SEAL, IWIS SURVEY MAP OR COPIES ARE NOT VALID. I IV 112, I.R. /RILB 4596 N.R. NON -RADIAL 2.jUNLESS EA48OSSEi PR A ieliWM TITLE: INFORMATION FURNISHED TO THE SURYFYOR, THERE U4Y OF OTHER RESTRIC710N`3 RECOVERED CAL.C. CALCULSATPOII OR FASb4CNTS TMr AFFECT THIS PROPERTY- OCATFO UNLESS OTHERWISE SHOWN. R END, PEICENIERLiNC FINISHED FLOOR ELEVATION 5. -THIS SURVEY IS PREPARED -FOR THE SOLE BENEFIT OF THOSE CERTIFIED TO AND SHOULD NOT BE RELIED UPON BY ANY OTHE - N?. NAIL & DISK B BUILDING SETBACK LINE PROVEMENTS HEREON SfJOULD NOT BE USED To RECONSTRUCT BOUNDARY LINES R/v RIGHT-LIF-VAY D.M. BENCHMARK . 6, DIMENSIONS SHOWN FOR PfE LOCATION OF IM SE DEARING (0.&) BASE BEARING 7._HWINGS,_ARE W,5ED ASSUMED DATUM AND ON THE LINE SHOWN AS IIA S i, EAS IMAGE B.B. ROr4 -Sh"WN, ARE RASE6'dN NATIONAL GEGDf.00 VERIICAL DAT11M OF 1929, UNCESS OTHERWISE NORI). U1 UTILITY 9. CERTIFICATE OF AUTHORIZATION NV. 4,596. C L CHAIN LINK FENCE ;; By'. B DATEPOINTOFCURVATURE ORDER N,;. MINT OF TANGENCY CERTIFIED-BY. CHORD MIS BUiLDING\PROPERTY DOES NOT LIE WITHIN ' LL 4714 LgAy ENGINEERING SCIENCES Consultants In: Geotechnical Engineering - Environmental Sciences Geophysical Services III, Construction Materials Testing Threshold Inspection Building Inspection - Plan Review - Building Code Administration UESProjectNo: 0110.1700817.0000 Workorder No: 9390532-1 Report Date: - 7/9/2018 353 2 Maggie Blvd, Orlando, 32811 - P: 407.42&0504 - F: 407.423.3106 In -Place Densily Test Reigiort Client: Park Square Homes 07 1- UES Technician: Raimundo, Salazar To( 5200 Vineland Road, Suite 200 ested: 07/09/2018Orlando, FL 32811 LD;ftte T y fm 0' F1 Project: Wyndham Preserve, House Lo S in East Lake Mary Boulevard. & Brisson Avenue South, Sanford, Seminole County, FL 32773 Area Tested: Residential House Pad ( Lot 173 Type of Test: Material. 'Fill Field: ASTM D-2937 Drive Cylinder- Method, ASTWDF1,557-Mo-dified iProt;t6r- Rdf6-f&ncd-DAturI -0 Bottotri-of FoUndlation- Footing Laboratory: The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. Test No. Location of Test Range Ulaximurn Density Pcf) Dptimurn Moisture Field Dry Density Pcf) Field Moisture Soil Compaction Fill Depth inch) Pass or Fail 1 South Side Footing 0-1 ft 106.8 10.6 103.7 10.3 97 N/A Pas! 2 West Side Footing 1-2 ft 106.8 10.6 104.3 10.9 98 N/A Pas: 3 North Side Footi ng 1-2 ft 106.8 10.6 104.5 10.6 98 N/A Pas! 4 East Side Of Pad 1-2 ft 106.8 10.6 104.9 10.0 98, N/A Pas! 5 Center Of Pad 2-3 ft 106.8 10.6 104.0 11.5 97 N/A Pas: Remarks: 3917 Salt Marsh Loop. L. 15 lightyears, Inc 776 Bennett Drive Longwood, Florida 32750 June 1, 2018 To: Local Building Department RE: Blower.Door Test & Duct Leakage Test Reports To whom it may gohcern,. This letter is to request that t,he attached, forms be accepted for compliance of the 2017 Florida Building Code statute R402.4.1.2 Envelope lelaka ge testing (Blower Door Testing) and R403.3.3 Duct testing - The attached forms were by the Florida Building Commission as the accepted forms to be submitted. These forms are listed on the 20 , 17 Florida Building Code, Energy Conservation Technical Assistance Manual, Document Number: TAM-2017-1.0, released February 02, 2018, pages R-78 through R-80 (page numbers 159-161). Web link provided for quick access to the TAM document hftps://tinyuri.com/2017FBC-TAM These ' forms meet all three required Residential Energy Efficiency Compliance Paths listed under R401.2, Prescriptive, Performance, and Energy Rating Index (ERI) paths. We are.working with building departrhe.nts.across Florida to standardized the form submiftal process and would, like your department to allow —these forms to meet compliance. If there are any issues with accepting these forms, please reach out to me directly and I will, ensure that we submit any specific form equi ligthatyouwillrre. Tim Smith (407)-951-3236 tsmith@15 htyears.com Respectfully, othy Sififth 15 Lighty6ars, Chief Operations Officer Energy Technical Advisor iZESNET Quality Assurance Oesig'nee IECC Residentiall Energy Inspector/ Plans Examiner Member, Building Officials Association,of Florida Member and Code Development. Committee participating member Also, representative to the Florida Building Commissions, Energy Technical Advisory Committee for the BOAF- CDC FORM R 405.4.11-2017 Enyelope LeakageTest Report(Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building -Code, Energy Conservation, 6th Edition jurisdiction f q I)C Srrj, a L I' Permit 4f: Lot: /Ty Zip: - , 1."Exit e'nor W i r,',dows,p-o,,doo"e,'fireoI nd stove,d6o 15 Liahtvears, Inc -438-15,15com, pany Name. Phone: (855) I h,ereby verify that the above Air Leakage results are in accordance with the 2017 6th.Edition Floricl& Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: Will Torres 9704654' License/Certification #: Issuing Authority: RESNET r7nDRA DAn')-')()17 Community: 406bc,1.1 12fe.3e rvv Lot: P Unit: St.ate: Zip: 11 r1l. System 1 P- cfm25 System 2 cfm25 Sy tem 3 cfm25 um of any additional systems cfm25 Tota I 'of -a I I systems cfm25 Certification Date: November 7, 2018 Certification Expires: November 7, 2021 Tim Smith, RESNET Quality Assurance Designee Perm t -IT- 4fe 13 -Z Teak%iBdB1111'1-111,11earls Statement Certain' p1111 I' U'r-Sadef®R S, F"ber Glass BI 1 nsu at k,)nIOwing t-13"le :bs,12 Name cn Addn:, American Rp$idpnt@f product, y Nar" m Name D i ictr j" DAW em IPEP, C ML,X3 ALED wmm ss q77 42 .6 4, am j A4-s IfL. 1?'E'RF:GR1iAANC:E AITIC j3LO. qM, ppUrWA ATjb'N, fin ac r l"n;Q with the chart ahove, you oiusfirf tall the minirnum"nurn I ber of bags, per 1,WO N ft of netar ea foe. esrh 1-1 ff r xix-;mum not GoveraqLa, t, t, qxooeid,that specMemforaach R-Vattle. Pie' 131j J'Afi)n MUSt b e'ihstaHadlet Or aboVe-the.,P,e llfted imstallled thi6Tmss for eacb;e4alve. R:01 tnjnhumve g p ic. essht", er tq. ft. of irlsulabon al or,'ziboviD tjj infti al insWed th kn will IT"'IM rl uci-d 11-Value. Thi )riXAK,-! s!"DIM riot be mixed with other'blown.insulatbrfs or ft thermal cWms willbecome invalid. LIGHT R)7UAtt — -Tib,PRIEVE I MT OVERHEATING, 130. NOVINWI-VE ON TOP ORWITH'IN T: OF DI-r-MES, THIS WARNING 00 NOT APPLY TO TYPEIC LltH 'ETFIXTUIRESCIPTOFLUOR §mUl' NUTURUS VATH THEMA LLY PROTECTE-D BALLASTS. CITY OF SANFORD BUILDING & FIRE PREVENTION 6 c) fe—n PERMIT APPLICATI ON fy] Application No: Documented Const Job Address: c)cp Historic District: YesEl No D Residentiqjlq<Ommercial Parcel ID: Demo[] ChangeofUse[I MoveTypeofWork: New-0-`Zddition 'AlterationEl Repair Description of Work: CjCCA-C,(-_(-_J Title: Plan Review Contact Person: Phone: Fax:, Email: Property Owner Information Phone: Name Resident of property? Street: City, State Zip: Contractor Information Name Phone: 81-3-910'34_0 Street' 103q 59ip e r Fax., tate License No.: (It' City, State Zip: S Architect/Engineer Information Phone: Name: Street: F I ax: E-mail: City, St, Zip: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOURPROpERTY. A NOTICE OF COMMENCEMENT MUST BEPAYINGTWICEFORIMPROVEMENTSTOYOURINTENDTOOBTAINHEJOBSITEBEFORETHEFIRSTINSPECTION. IF YOURECORDEDANDPOSTEDONTFORERECORDING YOUR NOTICE OFANATTORNEYBEFINANCING, CONSULT WITH YOUR LENDER OR COMMENCEMENT. workor installation hasandinstallationsasindicated. I certify thatnoApplicationisherebymadetoobtainapermittodotheworkmeetstandardsofalllaws regulating constructionpermitandthatallworkwillbeperformedtocommencedpriortotheissuanceofainthisjurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. ate: 51h Edition (2014) Florida Buildin g CodeFBC105.3 Shall be inscribed with the date of application and the code in effect as of that d Pemit Application Revised4l-30,2015 op,ty that may bebeadditionalrestrictionsapplicabletothisIn NOTIME: In addition to the requirements of this permit, there may other governmental entities such as 'ate' found inthe public records ofthis county, andthere may be additional -permits required from management districts, state agencies, or federal agencies. the Property of the requirements of Florida Lien Law4 Acceptance of Permit is verification that I will notify the owner o.f - A-copyof,tb-exe.t d_cont,acCLq jjequkedbittat- Th. City d requires payment of a plan review fee at the time of permit su In * )n value o,fthe job at tbe time of submittal. of S-fo"e . plan review charge and will be considered the estimated constrticti, a effect at the time the permit is issued, ininordertocalculaturedbasedonthecurrentICcValuationTablei . al construction value, The actual consMction value will be fig c ' cuted contract exceed the actu accordance with,tocal ordinance. Should aic ' ulated charges figured off the exe . credit will be applied to your permit iees when the permit is issued at all work willegoinginformationisaccurateandthcertifythatailofthefolaning. OWNER'S AFFIDAY ting construction anplicablelawsregulbedoneincompliancewituallap te sn o Ag lt ate Tg--awre of 0-ier/Agent pri n C-tractcr/Agent's NBTe Print owner/Agent' Narne qbs DM sip-t-` 442"`Y-st"Suf FROK (),Clair Date ig— JN,-State of F1.6d. # GG15`1707 15.2021 bonu tuiWlu Pe sonally Known torWCrintractor/Agent isnt owner/Agent'is Personally Known to Me or Typ eproduoedIDTyp Produced ID Type of_ID BELOW IS FOR OFFICE USE ONLY Gas[] ROOfF1 El ' 'icaln Mechanical 0 PlumbingnPermitsRequired: BuildingEl q tr Flood Zone: Occupancy Use: -------- Construction Type'—-- of Stories'. — Min. occupancy Load: Total Sq Ft ofBId9'.-------- Tlumbihg - of Fixtures_ New Construction' Flectric - 0 Of AMPS---- e Alarm Permit:' Yes No El Fire Spri I nkler Permit: Yes No 4 Of Heads Fir WASTE WATER: APP I ROVALS: ZoNrNG:— - UTILITIES: BUILDING:-- FIRE: — — — ENGINEERI14G: comMENTS: pemit Application R-i&: J,,- 30,2015 CONTRACT AGREEMENT 1 PAGE 1 4 1 OF 41 JOB NAME: DATE: 6/21/2017 PROPERTY OWNER ORHIS AGENT:_ -pQcumEw:-ELECTRICAL-CONTRACT-.REVISE D----- PARKSQUARE HOMES LEVEL I - WITH CFL BULBS I fugu GAS/ELECTRIC AW2=: 5200 VINELAND RD MAgm: ORLANDO M: ORLANDO a=: FL =:SANFORD WYNDHAM PRESERVE PLAN SERVICE SIZE SQ FT A/C SYSTEM PRICE SEBRING 200A 2410 10-kWHEAT240 60A 6,758.00 S-TON AC 240V, 5 A SORRENTO 200A 2078 8-kW HEAT 240V, SOA 5,465.00 4-TON AC 24OV, 40A SPRUCE 200A 2774 8-kw HEAT 240V, SOA 7,264.00 4-TON AC 240V, 40A SUNDANCE 200A 1730 5-kW HEAT 240V, 35A 5,081.00 3-TON AC 240V, 30A TELLURIDE 200A 2637 10-kW HEAT 24OV, 60A 6,601.00 5-TONAC24OVS A TRIBECA 200A 1986 8-kW HEAT 240V, SOA 5,608.00 4-TON AC 240V, 40A TUSCANY 200A 2718 10-kW HEAT 24ov, 60A 6,818.00 5-TON AC 24OV, 5 A WALTON 11 200A 1811 8_kW HEAT 240V, SGA 5,110.00 4-TON AC 240V, 40A WELLINGTON 200A 3075 QTY 2) 5-kW HEAT Mov, 35A 7,S87.00 QTY 2) 3-TON AC 240 OA CONTRACTOR/OWNER: EDMONSON ELECTRIC:- 1034 ' Skipper Road Tampa, I Phone:(813)910-34U3 - Fa FILDIEDA LICENSE# ECIM5408 10-8546 - DATE: DATE. 11"IZ1111,17 K) V I- I-S, 1111i fill I'll E iR 1.' T i j 1 17 2 L-1`-.1RK 2.1 THIS INSTRUMENT PREPARED BY: Name: Tania Pickering Address: 5200 Vineland Road Suite 200 Orlando, Florida 32811 NOTICE OF COMMENCEMENT Permit Number: 18-1392 Parcel ID Number: 17-20-31-502-0000-1730 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) Lot 173 Wyndham Preserve Plat Book 81 / Pages 93-102 3917 Saltmarsh Loop, Sanford FL 32773 2. GENERAL DESCRIPTION OF IMPROVEMENT: Construction of a new single family residence 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: Park Square Enterprises LLC 5 00 Vineland Rd Suite 200 Orlando FL 32811 Interest in property: Fee Simple Fee Simple Title Holder (if other than owner listed above) Name: 4 ( Address: 4. CONTRACTOR: Name: Park Square Homes Phone Number: 407-529-3000 Address: 5200 Vineland Road Suite 200 Orlando, Florida 32811 5. SURETY (if applicable, a copy of the payment bond is attached): Name: N/A Address: N/A Amount of Bond: N/A 6. L . ENDER: Name: Fifth Third Bank Phone Number: Address: 5050 Kingsley Dr. MD: 1 MOM Cincinnati, OH 45227 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(l)(a)7., Florida Statutes. Name: Phone Number: Adaress: 8. In addition, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(l)(b), Florida Statutes. Phone number: 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. I IUA Signature of Owner or Liessed, ort sntP. glesgiee's Authorized Officer/D rector/ r) Vishaal Gupta, Executive Vice President Print Name and Provide Signatory's Tiqe/Office) State of County of The foregoing instrument was acknowledged before me this 13 dav of 20 AL by jy Id IWW- Who is personally known to me 0 OR Name of pers6n nYAking statement who has produced identification 0 type of identification produced: k1A- .0 ft*— n A MASK Ar W CMISSION # FF M9108 EXPIRES: 4ne ?7,2019 4OF Sow Tom 10I.P.1 041ary smit" Notary Signature a A LCORD COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project N ' ame: Lot 173 Sorrento A LHG - S Builder Name: Street: 3917 Saltmarsh Loop Permit Office: City of Sanford BU/4'0/ City, State, Zip: Sanford , FL , Owner: Park Square Homes Permit Number 1 3 Jurisdiction: 6#15010 8 9 2 S G) ts Climate Zone 2 0% Design Location: FL, Orlando County:: Seminole (Florida Afe-AA1. New construction or existing New (From Plans) 9. Wall Types (2612.7 sqft.) Insulation 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1302.00 ft2 b. Frame - Wood, Exterior R=1 1.0 1026.00 ft2 3. Number of units, if multiple family I c. Frame - Wood, Adjacent R=1 1.0 284.67 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (1517.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1517.00 ft2 6. Conditioned floor area above grade (W) 2078 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(231.0 sqft.) Description Area a. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor 6 415.6 a. U-Factor: Dbl, U=0.55 135.00 ft2 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.58 64.00 ft2 12. Cooling systems kBtu/hr Efficiency a. Central Unit 34.8 SEER:16.00 SHGC: SHGC=0.25 c. U-Factor: Dbl, U=0.54 32.00 ft2 SHGC: SHGC=0.25 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 33.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 2.755 ft. Area Weighted Average SHGC: 0.232 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2078.0 sqft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 1324.00 ft2 b. Conservation features b. Floor Over Other Space R=0.0 561.00 ft2 None c. other (see details) R= 193.00 ft2 15. Credits Pstat Total Proposed Modified Loads: 62.25 PA S SGlass/Floor Area: 0.111 Total Baseline Loads: 65.93 I hereby certify that the plans and specifications covered by Review of the plans and I E.. S. this calculation are in compliance with the, Florida Ener2y specifications covered by this 0 Code. Bojan Digitally signed yBojan Paukovic calculation indicates compliance PaUkovic CIDat- 2018.03.12 12:55:03 with the Florida Energy Code. PREPARED BY: 04'0 Before construction is completed 0Rq' DATE: this building will be inspected for compliance with Section 553.908 A: LE I hereby certify that this buildin desig d, is in com plianceiin Florida Statutes. with the Florida Energy CrgyC OWNER/AGEN BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1.. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. 3/12/2018 12:50 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: Lot 173 Sorrento A LHG - S Bedrooms: 4 Address Type: Lot Information Building Type: User , Conditioned Area: 2078 Lot # 173 Owner Name: Park Square Homes Total Stories: 2 Block/Subdivision: WYNDHAM PRESERV of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 45 Street: 3917 Saltmarsh Loop Permit Office: City of Sanford Cross Ventilation: No County: Seminole Jurisdiction: 691500 Whole House Fan: No City, State, Zip: Sanford , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily TempVDesignLocationTMYSite97.5% 2 5 % Winter Summer Degree Days Moisture Range FL, Orlando FL—ORLANDO—INTLAR 41 91 70 75 526 44 Medium BLOCKS Number Name Area Volume 1 Blockl 2078 19099.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1 st Floor 1324 12313.2 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 754 6786 No 3 3 1 Yes Yes Yes FLOORS y# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Floor over Garage 2nd Floor ---- ---- 193 ft2 11 0.29 0 0.71 2 Slab -On -Grade Edge Insulatio 1 st Floor 139.5 ft 0 1324 ft2 0.29 0 0.71 3 Floor Over Other Space 2nd Floor ---- ---- 561 ft2 0 0.29 0 0.71 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. deg) 1 Hip Composition shingles 1697 ft2 0 ft2 Dark 0.9 N 0.9 No 0 26.6 ATTIC V# IRCCTypeVentilationVentRatio (I in) Area RBS 1 Full attic Vented 300 1517 ft2 N N 3/12/2018 12:50 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 r-uh1vi r14U0-'1-U 1 1 CEILING y Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) 1 st Floor 30 Blown 1517 ft2 0.1 Wood WALLS Adjacent C yiht Width Height Sheathing Framing Solar Below WAll IN/pe Space 1P Ft In Ft In A rpn R-Vnlue Ernnfinn Ahqnr, Gr;;dP01, It 1 Ornt Tn SW=>W Exterior Frame'- Wood 2nd Floor 11 27 0 9 0 243.0 ft2 0 0.25 0.8 0 2 SW=>W Exterior Concrete Block - Int Insul I st Floor 4.1 44 6 9 4 415.3 ft2 0 0 0.8 0 3 SE=>S Exterior Frame - Wood 2nd Floor 11 30 0 9 0 270.0 ft2 0 0.25 0.8 0 4 SE=>S Exterior Concrete Block - Int Insul 1 st Floor 4.1 10 0 9 4 93.3 ft2 0 0 0.8 0 5 NE=>E Exterior Frame - Wood 2nd Floor 11 27 0 9 0 243.0 ft2 0 0.25 0.8 0 6 NE=>E Exterior Concrete Block - Int Insul 1 st Floor 4.1 55 0 9 4 513.3 ft2 0 0 0.8 0 7 NW=>N Exterior Frame - Wood 2nd Floor 11 30 0 9 0 270.0 ft2 0 0.25 0.8 0 8 NW=>N Exterior Concrete Block - Int Insul 1st Floor 4.1 30 0 9 4 280.0 ft2 0 0 0.8 0 9 N Garage Frame - Wood 1 st Floor 11 30 6 9 4 284.7 ft2 0 0.25 0.8 0 DOORS V Ornt Door Type Space Storms U-Value Width In Height Ft In Area Ft 1 SE=>S Insulated 1 st Floor None 4 3 8 24 ft2 2 -=>N Wood 1 st Floor None 46 2 7 8 20.7 ft2 WINDOWS Orientation shown is the entered orientation changed to As Built (rotated 45 degrees). Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade ScreeningV 1 SW=>W 2 Metal Low-E Double Yes 0.55 0.22 N 45.0 ft2 1 ft 0 in 1 ft 0 in DrapesIblinds None 2 se=>S 3 Metal Low-E Double Yes 0.55 0.22 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 3 se=>S 3 Metal Low-E Double Yes 0.54 0.25 N 12.0 f t2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 NE=>E 5 Metal Low-E Double Yes 0.55 0.22 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 NE=>E 5 Metal Low-E Double Yes 0.54 0.25 N 4.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 6 NE=>E 6 Metal Low-E Double Yes 0.55 0.22 N 115.0 ft2 1 ft 0 in 1 ft 0 in DrapesIblinds None 7 NE=>E 6 Metal Low-E Double Yes 0.54 0.25 IN 4.0 ft2 I ft 0 in 1 ft 0 in Drapes/blinds None 8 1 NE=>E 6 Metal Low-E Double Yes 0.54 0.25 N 8.0 ft2 I ft 0 in 11 fto in Drapes/blinds None 9 nw=>N 7 Metal Low-E Double Yes 0.55 0.22 N 15.0 ft2 1 tt 0 in 1, ft 0 in Drapes/blinds None 10 nw=>N 7 Metal Low-E Double Yes 0.54 0.25 N 4.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 11 nw=>N 8 Metal Low-E Double Yes 0.55 0.22 IN 30.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 12 NW=>N 8 Metal Low-E Double Yes 0.58 0.25 N 64.0 ft2 7 ft 4 in 1 ft 0 in None None 3/12/2018 12:50 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 420 ft2 420 ft2 64 ft 9,3 ft INFILTRATION Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000409 2228.2 122.33 230.05 .3674 7 HEATING SYSTEM y # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:9 33 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 34.8 kBtu/hr 1044 cfm 0.75 1 sys#1 HOT WATER SYSTEM y# System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 70 gal 120 deg None SbLAR HOT WATER SYSTEM VFSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS Supply ---- Location R-Value Area Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handier TOT CUT ON RLF HVAC # Heat Cool 1 Attic 6 415.6 ft 2nd Floor 103.9 ft Prop. Leak Free 2nd Floor --- cfm 62.3 cfm 0.03 0.50 1 1 1 3/12/2018 12:50 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 r:r)MKA MAf)r,-0017 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb ar Apr Ma y Jun Jul Aug Sep Oct No', Dec Heating Jan F eb MarN Apr May Jun JUJ1 AugJ1 Sep 0 t NN Dec Venting Jan Feb Mar Apr May Jun Ju[ Aug Sep Oct Nov Dec Thermostal Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 6 PM 68 68 68 68 68 68 68 68 68 68 66 66' 3/12/2018 12:50 PM EnergyGauge(& USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 3917 Saltmarsh Loop Permit Number: Sanford , FL , MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law. Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approv ed third party shall inspect all components and verify compliance. I R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal ejnvelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1 . Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 1 Ol/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 3/12/2018 12:50 PM EnergyGauge@ USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1 . Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1 006 of the Florida Building Code, Residential. R402.4.5 Recessed fighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating an f d cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric-resi stance heat shall have controls that, except during defrost, prevent supplemental, heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or 7), Florida Statutes, or individuals licensed as set forth in Section 489.1 05(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1 Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105*F (41 1C) or below 550F (1 3oC) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 3/12/2018 12:50 PM EnergyGaugeG USA - FlaRes2017 - FBC 6th Edition (2017) Complian Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 1 00'F to 140OF (38oC to 60oC). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. F11403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table k403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. 1 The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from.attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-1 1 and the ceiling shall be insulated to a minimum of R-1 9, space permitting, or R-1 0 otherwise. R403.7 Heating and cooling equipment (M6ndatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM) MINIMUM EFFICACY a CFM/WATT) AIRFLOW RATE MAXIMUIv, CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1. 4 cf m/watt 90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 L/min. a. When tested in accordance with HVI Standard 916 3/12/2018 12:50 PM EnergyGauge@ USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. . Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1 Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1 . A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50oF (1 OoC), and no precipitation is failing and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F (4.8oC). R403.1 0 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.1 0.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste- heat-recove ry pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retarda,nt cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 3/12/2018 12:50 PM EnergyGauge@ USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatory)he energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 3/12/2018 12:50 PM EnergyGauge@ USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 5 of 5 FORM R405-2017 NEW: DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 3917 Saltmarsh Loop, Sanford, FL, 1 . New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1302.00 ft2 b. Frame - Wood, Exterior R=1 1.0 1026.00 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=1 1.0 284.67 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types Insulation Area S. Is this a worst case? No a. Under Attic (Vented) R=30.0 1517. 00 ft2 6. Conditioned floor area (ft2) 2078 b. N/A R= ft2 c. N/A R= ft2 7. Windows- Description Area 11. Ducts R ft2 a. U-Factor: Dbl, U=0.55 135.00 ft2 a. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor 6 415.6 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.58 64.00 ft2 SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.54 32.00 ft2 a. Central Unit 34.8 SEER:16.00 SHGC: SHGC=0.25 d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 33.0 HSPF:9.00 Area Weighted Average Overhang Depth: 2.755 ft. Area Weighted Average SHGC: 0.232 8. Floor Types Insulation Area 14. Hot water systems Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1324.00 ft2 a. Electric EF: 0.9 b. Floor Over Other Space R=0.0 561.00 ft2 b. Conservation features c. other (see details) R= 193.00 ft2 None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. t a new EPL Display Card will be completed based on installed Code compli t f tures. Builder Signature: Date: le) Address of New Home: City/FL Zip: Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/12/2018 12:50 PM EnergyGaugeg USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 173 Sorrento A LHG - S Builder Name: Street: 3917 Saltmarsh Loop Permit Office: City of Sanford City, -State, Zip: Sanford , FL , Permit Number: Owner: Park Square Homes Jurisdiction: 691500 Design Location: FL, Orlando COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per,inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Pytgnd behind pipino and w'rinn- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-seaied boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids hp.twp.pnfir s ri nkler rnvpr p a 120 walls or ceili nos, a. In addition, inspection of log wall s a the provisions of ICC-400. 3/12/2018 12:50 PM EnergyGauge@ USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft, Project Summary En tire House One Stop Cooling and Heating Job: Sorrento A LH G Date: 03/05/2018 By. LF/RI/BP/AT/MC 7225 Sandscove court, Wirfter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopGooling.com License: CAC032444 W- N, I, M`10,1,101aggWE . ... .... . , W61 Ih, in W For: Park Square Homes FL Notes: Weather: Orlando Intl AP, FL, US Winter Design Conditions Outside db 42 IF Inside db 68 IF Design TD 26 IF Heating Summary Structure 20454 Btuh Ducts 2266 Btuh Central vent (0 cfm) 0 Btuh gone) Humidification 0 Btuh Piping 0 Btuh Equipment load 22720 Btuh Method Construction quality Fireplaces Infiltration Heating Simplified Average 0 Coolin 211 19452 0.21 68 Area (ft2) 211 Volume (ft3) 19452 Air changes/hour 0.41 Equiv. AVF (cfrn) 133 Heating Equipment Summary Make Trane Trade TRANE Model 4TWR6036H1 AHRI ref 7562981 OMNI00n", Summer Design Conditions Outside db 92 OF Inside db 74 IF Design TD 18 OF Daily range M Relative humidity 50 Moisture difference 49 grAb Sensible Cooling Equipment Load Sizing Structure 20859 Btuh Ducts 4681 Btuh Central vent (0 cfm) 0 Btuh none) Blower 0 Btuh Use manufacturer's data n Rate/swina rnulti ier Equipmerif sensig, e load 0.97 24876 Btuh Latent Cooling Equipment Load Sizing Structure 4048 Btuh Ducts 971 Btuh Central vent (0 cfm) 0 Btuh none) Equipment latent load 5019 Btuh Equipment Total Load (Sen+Lat) 29896 Btuh Req. total capacity at 0.75 SHR 2.8 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TWR6036H1 Coil TEM6A0C36H31 ++TDR AHRI ref 7562981 Efficiency 9 HSPF Efficiency 13.0 EER, 16 SEER Heating input Sensible cooling 26100 Btuh Heating output 33000 Btuh @ 47oF Latent cool i ng 8700 Btuh Temperature rise o IF Total cooling 34800 Btuh Actual air flow 0 cfm Actual air flow 1160 cfm A r flow factor 0 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H20 Static pressure 0.50 in H20 Space thermostat Load sensible heat ratio 0.84 Capacity balance point = 32 OF Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Mar-12 12:48:14 Right -Suite@ Urtiversal 2018 18.0.11 RSU1 6877 Page 1 ACCI", sktop\TEMP PRINT\Lot 173 Sorrertto A LHG - S.rLp Calc = MA House faces: S Job: Sorrento A LH G FF wrightsoft, Right-J@ Worksheet Date: 03/05/2018 Entire House By. LF/RUBIPIAT/IVIC One Stop Cooling and Heating 7225 Sandscove Gout Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: wmuOneStopCooling.com License: CAC032444 1 Room name Entire House PWDR 2 E)posed \Aell 253.5 ft 12.0 ft 3 Room height 9.2 Ift d 9.3 ft heat/bool 4 Room dimensions 4.5 x 7.5 It 5 Room area 2117.3 ft2 33.8 ft2 Ty Construction number U-value BtuM-+ or HTIVI Btuh/fl Area (f[2) or perimeter (ft) Load 8tuh) Area (ft2) or perimeter (ft) Load Btuh) H eat Cool Gross N/P/S Heat cool Gross N/P/S Heat Cool 6 1'1 G 126' 13A-4ocs 4A5-2om N b.'60' 3.540 0.143 0.550 ne, n'e' ne ne 14.38 3.73 14.35 2 MI '4 23:59:,, 2.90 22.14 43 15 4 512 15 485 0 1808 215 1403 332 70 0 66 0 245 0 0 0 190 0 4B5-2tm 4B5-2fm 4A5'26m-,--ff 0.540 O-W 0 -5,'4 0 ne ne dse 14.09 14.09 53 4bq. 23.59 23.59 21w: Sm 4 8 i I 0 0 56 113 2 94 189 2 63 0 4 0 , 0 0 0 0 56 b 0. 0 94 0 0 t-D 3A-4ocs111DO 12B' 0.143 0.390 U97 s'e- sk! 3.73 10.18 2.90 12.27 93 24 L, . I 69 24 11 258 244 L5' 200 294 685 42 0: 42 0 b 156 I'l-i" I 121 0 1: 1 '.' Q, 13A-4ocs 4A5-2om 4'Mw,2 orrY: 13 - A- . 4ocs 0.143 0.550 Z 097 550 L,40 6.143 sw sw nw nw nw 3.73 14.35 3.73 2.90 21.42 214 2 6 2.90 414 45 279 , 369 6 O 0 1 85 1377 646 515 690 1068 964 536 0 0 b 0 0 0 q"" 0 0 0 b 0 0 0 0 4A5-2om 4A5-2omd i2C O§i U-'r:i:,,,.-,-,-'-''.!A';! 0.550 0.580 nw nw j n. 14.35 15.14 38 0 i 8 22.14 27.72 15! 1227 30 64 284. 21 0 0 263 431 969 25 664 1 T74 396 1253 0 0 0 0 0 0 W; 6 0 0 0 C F" 166-30ad I 0 332 0: 0.44 1.7 0.31 1517 1517 V4 1267 2668 0 P':"qbj, 0 b o 0 F 22A-tnm b:649 1.1801 30.80 0.§ 1324 140 4296 0 34 12 370 01 61 c) AED excursion 1 6751 1 -7 Envelope loss/gain 16652 15717 828 399 12 a) Infiltrallon 3802 1373 183 66 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 9 2070 0 0 Appliancestother 1700 0 Subtotal (lines 6 to 13) 20454 20&591 1010 464 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 865 411 14 Subtotal 20454 20859 1875 876 15 Ductloads 11%1 22-/.l 2266 4681 11%1 22%1 1 9tal ro?m load 227201 25540 1 208211 1073 ir required (cfm) 01 1160 1 0 49 Calculations aoiDroved bvACCA to meet all reauirements of Manual J 8th Ed. 4- 2018-Mar-1 2 12:48:14 405*1 1""--11"-'- Right-Sute@ Uriversal 2018 18.0.11 RSUI 6877 Page 1 sktop\TEMP PRINT\Lot 173 Sorrento A LHG - S.rulo Calc = MJ8 House faces: S wrightsoft, Right-J@ Worksheet Job: Sorrento A LH G Entire House Date: 03/05/2018 By. LF/RI/BP/AT/MC One Stop Cooling and Heating 7225 Sandscove CoutWinter Park, FL 32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: wwwOneStopCoolirg.com License: CAC032444 1 Room name STC1 LNDY 2 E)posed viall 17.0 ft 0 ft 3 Room height 9.3 ft heattcool 9.3 ft heaVcool 4 Room dimensions 4.5 x 17.0 ft 6.0 x 7.5 ft 5 Room area 76.5 ft2 45.0 ft' Ty Construclion number U-\ralue l3tuMf--q or HTM BtuhtV) Area (ft2) or perimeter (ft) Load Btuh) Area (ft2) or perimeter (ft) Load l3tuh) Heat Cool Gross N/P/S Heat cool Gross N/P/S Heat Cool 6 A 28" 5, 0' 4A 2. 0.097 3 2 82 P'0 b b MITb 6 M-0 x 'b 0 11 13A-4ocs, 4A5-2om 0.143 0.550 ne ne 3.73 14.35 2.90 22.14 58 0 1!4 0 575 0 446 0 0 0 0 0 0 0 0 0 1-D 4135-2fm 4135-2frn 4A5 -2orn J 413 3A-4ocs111DO 0.540 0.540 0097 350C).5 0.143 0.3,90 ne ne se se J se se 14.09 14.09 3.73 10.18 2. 23.59 23.59 M 1 42 2 bO 2.90 2.27 Z82 0 4 20 0 0 0 0 0 0 0 O 0 56 Z -;b 0 0 0 0 94 0 0 0 0 0 6; 0- 0 R 0 0 0 0 0 0, 0 0 b 0 0 0 0 0 0 W 13A-4ocs 4A5-2om 12 El 0, m-, 0.143 0.550 580 sN SN jyw im 3.73 14.35 4.35' 09 2.90 21.42 8 2- 0 0 d 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 T-j4A5-2omd D, 13A-4= 4A5-2orn IDO 540 0.143 0.550 0.580 1 nw nw nw 3.73 14.35 15.14 38 0.18 2.90 22.14 27.72 0 1-51 12-27 0 0 0 0 1'() 0 0 0 0 0 0 0 0 0 0 0 v i ZO U 0 0 56 e,:,:,,-,:2 0 0 21 0 0 K, 210 0 0 0 53 C F 168-30ad gcscp 22A-tpm 0.032 1.180 0.84 0. 30.80 1.76 31 0.00 0 0 77 0 0 17 0 5,24, 0 0 0 0 45 0 0 0 0, 0 0, 0 ZX 7 z 1: N 2. 7, 5, z 7F VNE j me. 6 c) AED excursion 13 27 Envelope loss/gain 1155 528 294 279 12 a) Infiltration 259 93 0 0 lo) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 01 500 Subtotal (lines 6 to 13) 1414 621 294 77 1 Less external load 0 0 0 00 Lesstransfer 0 0 0 0 Redistribution 1414 621 284 1 82 14 Subtotal 0 0 578 961 15 Ductloads 1 11% 22% 0 0 11% 22% 64 216 Total room load 0 0 642 1177 Air required (cfm) 01 0 1 1 0 53 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. f4- 2018-Mar-12 12:48:14 RigN-Sute@ Universal 2018 18.0.11 RSU1 6877 Page 2 sktop\TEMP PRIN7\Lot 173 Sorrento A LHG - S.rup Calc = MJ8 House faces: S wrightsoft' Right-J@ Worksheet Job: Sorrento A LH G Entire House Date: 03/05/2018 By. LF/RI/BP/AT/MC One Stop Cooling and Heating 7225 Sandscove CourtWinter Park, FL 32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: vAkw0neStopCooling.rom License: CAC032444 I Room name KIT DINE 2 Bposed vall 10.5 It 9.5 It 3 Room height 9.3 ft heaticool 9.3 It heat/000l 4 Room dimensions 14.0 x 10.5 It 1.0 x 147.0 It 5 Rbom area 147.0 1`12 147.0 IF Ty Construction U-value or HTM Area (ft2) Load Area (ft2) Load number Btuh4F-,F) Btuh/W) or perimeter (ft) Btuh) or perimeter (ft) Btuh) H eat Cool Gross N/P/S H eat Cool Gross N/P/S Heat Cool 6 L 46 4A om 4B 5i 0;097 1;-0550 Ew he, ne e 14., 09 221.5G P 0 0 0 e" b b 2 0 o r -,b M: I 0 0740 13A-40cs 0.143 ne 3.73 2.90 0 0 0 0 0 0 0 0 11 4A5-2om 0-550 ne 14.35 22.14 0 0 0 0 0 0 0 0 4B5-2frn 0.540 ne 14.09 23.59 0 0 0 0 0 0 0 0 4B5-2fm 4 A5 - 0.540 0.540 ne 14.09 14.09, 23.59 2 A2 J, 21'.90 0 j A: 0 0 o 0 b 0 b 0 0 0 0 0 0 0 0 t-D 3A-4ocs111DO 1 2B-0 13A-4ocs 0.143 0.390 097' 0.143 se se sw 3.73 10.18 3.73 2.90 12.27 2.90 0 0 98 0 0 98 0 0 0 364 0 0 283 0 0 88 0 0 73 0 0 274 0 0 a 212 4B&2fnn' 4A5-2om 12 Osw- 13A-4ocs 0.550 0 0 0.143 sw nw, nw 14.35 2 1435 4 3.73 21.42 2- M 2214 2.90 0 0 0 0 0 jr 0 0 0 0 15 P 0 0 2 8 0 0 215 0 321 0 0 0 4A5-2om 0.550 nw 14.35 22.14 0 0 0 0 0 0 0 0 4A5-2omd 12c Osw 1 0.580 O'.b§l' Q 31 nw 15.14 2-38, 2772 2- 0 7 0 0 NO 0 0 0 0 4 0 0 C 1613-30ad 0.03 0.84 1.76 0 0 0 0 56 56 47 98 F., 19c"19csq 9 1:0. M 6 0 0 0 F 22A-inm 1.180 k.80 0.00 147 11 323 0 147 10 293 0 61 c) AED excursion 1 591 1 . 89 Envelope loss/gain 997 420 828 721 12 a) Infiltration 160 58 145 52 b) Roomventilation 0 0 0 0 13 Internal gain& Occupants @ 230 0 0 0 0 Appliances/other 1200 0 Subtotal (lines 6 to 13) 1157 1678 973 774 Less e)dernal load 0 0 0 0 Less transfer 0 0 0 0 Redistibution 63 40 113 72 14 Subtotal 1220 1718 1086 846 15 Ductloads 11% 22'/6 135 38 1 11% 22% 120 1901 Total room load 1355 2104 1207 1036 Air required (drn) 0 961 0. 47 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2018-Mar- 12 12:48:14 RigN-Suite@ Universal 2018 18.0.11 RSU1 6877 Page 3 sktop\TEMP P RIN-RLot 173 Sorrento A LHG - S.rLp Calc = MJ8 House faces: S wrightsoft, Right-M Worksheet Job: Sorrento A LH G Date: 03/05/2018 Entire House B)r. LF/RI/BP/AT/MC One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwuOrieStopCooling.com License: CAC032444 1 Room name GRT IvUED 2 E)posedvell 32.5 ft 39.5 It 3 Room height 9.3 It heat/cool 9.3 It heat/cool 4 Room dimensions 1.0 x 281.5 It 14.5 x 17.5 ft 5 Room area 281.5 f12 253.8 It' Ty Construction U-value or HTM Area M) Load Area (ft) Load number BtuMt--F) BtjhV) or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 4A5 2om 0': 0'97 0.550 n'E' ne- 53 4.3 2 'f2 14 0 b 0 0 0 Q n- 0 23.59 0 0 0 b b 11 4B5-2fm 13A-4ocs 4A5-2om 0.143 0.550 ne ne 3.73 14.35 2.90 22.14 0 0 0 0 0 0 0 0 0 i63 15 0 148 0 0 551 215 0 428 332 04135-2frn 4135-2frn 0.540 0.540 0R, `bM7 ne ne 14.09 14.09 23.59 23.59 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2fm j 4 6"" .90 0 4N4 0 0, I-D 3A-4ocs111DO 0.143 se 3.73 2.90 0 0 0 0 0 0 0 0 0 0 0 0 0 0, 0.390 se 10.18 12.27 0 0 M '0 b 0 D', 0 k,5,r j,n- 0 13A-4ocs 0.143 sw 3.73 2.90 158 30 128 4 478 431 371 643 70 0 70 260 0 202 04A5-2om 12 4'A-';-2om 0.550 97 W sw nw: w 1435 2M l 4.35 21.42 22-14 6 b 0 6 0 b 0, 0 540,` j 4 69 2 -.6b 0 00 0 0 13A-4ocs 4A5-2om 0.143 0,550 nw nw 3.73 14.35 2.90 22.14 144 0 80 0 299 0 232 0 135 30 105 0 361 431 304 664 4AS-2omd 0-1,80 nw 15.14 27.72 64 0 969 1774 0 0 0 0 0,09 z::O b M .,-0 o b 0 0 0 0 i d 0 b 0AlDo'i ` 0-990 n 10, 1 b 12 -2 I 0 0 i; L" 2 U C 16B-30ad 0.032 0.84 1.76 282 282 235 495 254 254 2112 446 F C-1 9csc' 19 P,:-, 0 -049 0 311 o b 0 0 F 22A-tpm 1.180 30.80 0.00 282 33 1001 0 40 1217 0 T T 2 2 rZ r d f K Z" 6 c) AED excursion 626 37 Envelope loss/gain 3413 4141 1 3278, 2413 12 a) Infiltration 495 179 6011 217 b) Room ventilat on 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Applianoe&bther 0 0 Subtotal (lines 6 to 13) 3907 4319 3879 30970 Less external load 0 0 0 0 Less transfer 0 0 0 Redistribution 0 0 0 14 Subtotal 3907 4319 3879 3090 15 Duct loads 433 969 11%1 22% 430 693 Total room load 4340 5289 4308 3783 Air required (cfrn) 0 2401 0 1 72 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2018-Mar-12 12.48:14 Rigll-Suite@ Unversal 2018 18.0.11 RSU1 6877 Page 4 sktop\TEMP PRINT\Lot 173 SorrertoA LHG - S.rLp Calc= MJ8 House faces: S 11 - Job: Sorrento A LIH G rF wrightsoft, Right-M Worksheet Date: 03/05/2018 Entire House By. LFIRUBIP/AVIVIC One Stop Cooling and Heating 7225 Sandsrove GoW, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: wwwOreStopCoolirig.com License: CAC032444 I Room name MTOI NUTH 2 Exposed wall 0 ft 13.0 It 3 Room height 9.3 It heal/cool 9.3 ft heat/bool 4 Room dimensions 3.5 x 6.0 ft 6.5 x 13.0 ft 5 Room area 21.0 f12 84.5 112 Ty Construction U-value or HTM At- (ft) Load Area Of) Load number BtuM?-0q BtuhAl2) or perimeter (ft) Btuh) or perimeter (ft) Btuh) H eat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 I 6, sw""' 2 q Q'Ibb§7 0 .5 0 n' re si 14 35 A Jz "7"'o 0 b 0 b 6 0 0 0 0 C) 0 0 11 13A-4ocs 4A5-2om 0.143 0.550 ne ne 3.73 14.35 22.14 0 0 0 0 0 0 0 121 0 117 0 436 0 339 01-=G 4135-2frn 0.540 ne 14.09 23.59 0 0 0 0 4 0 56 94 t-D Wr - -1 1 465-2fm jau 3A-4ocs111DO r;; 12 av 0.540 oj 0.143 0.390 ne se sell. se se sw: 14.09 09 3.73 10.18 23.59 1 A2 1'.90 2.90 1227 282 0 b,j 0 0 o 0 b 0 0 t ' M, I - "', p,, 0 0 0v ,' 0 d 0 0 N b 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0 G T--G 13A-, 4A5-2om rn, 13A-4ocs 0.143 0.550 540 0.143 sw sw 4w nw 3.73 14.35 435, 4.,bp 3.73 2.90 21.42 182 al 4 k ?3 2.90 0 0 b 0 0 0 b b 0 0 0 o 0 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 A- 0 0 0 0 b 0 0 4A5-20m 0.550 nw 14.35 2214 0 01 01 01 01 0 0 0 4A5-2omd 0.580 nw 15.14 27'.721 01 0 0 0 0 0 0 0 1 61 c) AED excursion 1 11 1 -21 Envelope loss/gain 18 361 950 532 12 a) Infiltration 0 0 198 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 18 36 1148 603 Less external load 0 0 6 0 Less transfer 0 0 0 0 Redistribution 0 0 749 337 14 Subtotal 18 36 1897 941 15 Duct loads 11% 22% 2 8 11% 1 210 211 Total room load 19 44 2107 1152 Air required (dm) 01 21 0 52_ Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. 2018-Mar-12 12:48-14 Right -Suite@ Universal 2018 18.0.11 RSU1 6877 Page 5 sktop\TEMP P RIN7\1-ot 173 Sorrento A LHG - S.rup Cale = MA House faces: S wrightsoft* Right-J@ Worksheet Job: Sorrento A LH G Entire House Date: 03/05/2018 By. I-FRUBPAT/MC One Stop Cooling and Heating 7225 SandsGove CoA Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wv OneStopCooling.com License: CAC032444 1 Room name MIC H 2 Exposed vell 0 It 5.5 It 3 Room height 9.3 ft heat/000l 9.3 It heat/cool 4 Room dimensions 1.0 x 60.9 It 1.0 x 172.9 It 5 Room area 60.9 It' 172.9 112 Ty Construction U-value or HTM Area (ft) Load Area (ft2) Load number Btuh4t2--0q Bbih/ft2) or perimeter (ft) Btuh) or perimeter (ft) 13tuh) Heat cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1'213-0 4135-2h, A:, 0.097 0 550 O w ne.. he 1435 1.4-09 2.82 22114 0 0 0 0 0 0 0 0 6 0 0 0 0 b b 0 11 13A-4ocs 4A5-2onn 0.143 0.550 ne ne 3.73 14.35 2.90 22.14 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 M465, 4135-2frn 4135-2fm 12B4" 0.540 0.540 0:097 K O.w ne ne se se 14.09 14.09 2 14 b 91 23.59 23.59 4 Z82 1 M 0 0 0 0 0 0 0 0 Z"Ze, 0 0 0 v"o 0 0 3- b 0 0 0 0 0 0 0 0 t--D 3A-40cs 1'1 DO 0.143 0.390 0;Q97 se se c 3.73 10.18 2.90 12.27 0 0 0 0 0 0 O 0 0 0 51 24 27 24 101 244 3A 79 294 o 13A-4ocs 4A5-2om 4Af-2om,,. 0.143 0.550 0097 0.560 0 .540 sw sw r1w hw' 3.73 14.35 53 1 4 35 1 4.bg 2.90 21.42 2 82 22:141 0 0 0 b 0 0 0 b:, 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 fl 0 0 b 0 0 0 0 G 13A-4ocs 4A5-2om 4A5-2omd 0.143 0.550 0.580 nw nw nw 3.73 14.35 15.14 2.90 22.14 27.72 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 b 6 691, 0 390 ZM 10'.1 8 1227 0 0 0"", 0 b 0 0 232 O C F 1613-30ad C19 -,19cST, 22A-tpm 0.032 O.G49 1.180 0.84 0.44, 30.80 1.76 0.31 0.00 43 61 43 0 0 36 1 -.1- 1 ' ' : ',, 0 Y" 76 b 0 0 0 i73 0 b 6 0 4, 11b 169 0 n 0 j Z Z,,', p Y ku Z 61 6 c) AED excursion 3 19 Envelope loss/gain 36 73 747 501 12 a) infiltration 0 0 84 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 36 73 831 532 Less external load 0 0 0 0 Less transfer 0 0 0 Redistribution 171 109 831 532 14 Subtotal 207 1 831 0 0 15 Ductloads 11% 22% 23 41 11 %1 22% 0 0 Total room load I 230 224 0 0 Air required (cfm) O 101 1 01 0 Cal cul ati ons approved by ACCA to m eet al I requi rem ents of M an ual J 8th Ed. 4- 2018-Mar-1 2 12:48:14 Rigli-SuteOUriversaI2018 18.0.11 RSU16877 Page 6 sktop\TEMP PRINT\Lot 173 Sorrento A LHG - S.rup Calc = M,18 HoLse faces: S Job: Sorrento A LHG rF wrightsoft, Right-JO Worksheet Date: 03/05/2018 Entire House B)r LFRUBPAT/MC One Stop Cooling and Heating 7225 Sardscove Court, Winter ParK FL 32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: wwwOneStopCoolirig.com License: CAC032444 1 Room name BED2 BED3 2 E)posed viall 25.0 ft 25.0 It 3 Room height 9.0 ft heaV000l 9.0 ft heat/cool 4 Room dimensions 13.5 x 11.5 It 1.0 x 164.0 It 5 Room area 155.3 ft2 164.0 #2 Ty Construction U-value or HTM Area (ft2) Load Area ft2) Load number Btulvft OF) Btjht2) or perimeter (ft) Btuh) or perimeter (ft) Btuh) H eat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coof 6 A 2 N ne 2.82 0 b"' b 0' 0 550' ne 14,35 2 214 0 0 b 0540 w 14.09 23.59 0 0_ 0 0 Vh 13A-4ors 0.143 ne 3.73 2.90 0 0 0 0 0 0 0 11 4A5-2om 0.550 ne 14.35 22.14 0 0 0 0 0 0 0 0 4135-2frn 0.540 ne 14.09 23.59 0 0 0 0 0 0 0 0 4135-2fnn 0.540 ne 14.09 23.59 0 0 0 0 0 0 0 0 1 213-0sw'e,-- 0.097 se f-,,,,,,,,2 53, x 5 9 213 0 21 42 0 0 0 0 5 2 321' 140 14,09 21.9bI b b b 0 T-D 3A-4o 11DO 0.143 se 3.73 2.90 0 0 0 0 0 0 0 0 0.390 se 10.18 12.27 0 0 0 0...1.. 0 0 0 12 0 097 23 A 04' 1'04 2, 2 92 3 t-G 13A-4ocs 0.143 sw 3.73 2.90 0 0 0 0 0 0 0 0 4A5-2om 0.550 sw 14.35 21.42 0 0 0 0 0 0 0 0 U97 rw 53 Z 122 270 300 o 4A5-26 M b 55o rrw 425 22.14 15 0 21 5 332 b 0 0. AE82firn',, I 1 11-1. 1 0.54P nW. 14-09 5923- 11. 1 0 4z,: _0 0 d 0- 13A-4ocs 0.143 nw 3.73 2.90 b 0 0 0 0 0 0 0 4A5-2om 0.550 nw 14.35 22.14 0 0 0 0 0 0 0 0 4A5-2omd 0.580 nw 15.14 27-72 0 0 0 0 0 0 0 0 A 26'_O k ::, 0 09f 2-38 1 11 1 51 0 b 0 V D 0 390' 2 27, D b 0, 0 C 1613-30ad 0.032 0.84 1.76 155 155 130 273 164 164 137 F 1`9C7 0.'44, b 3f 0 o A 0 90 F 22A-tlDm z, - 1.180 30.80 O.C 0 0 0 0 0 0 0 0 1 Z 5 6 c) AED excursion 70. 44 Envelope loss/gain 1 877 1267 1 928 1276 12 a) Infiltration 368 133 368 133 b) Room ventlaton 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliancesiother 0 0 Subtotal (lines 6 to 13) 1245 16301 12961 16391 Less e)dennal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1245 1630 1296 1639 15 Ductloads IN 22%1 138 366 11% 22% 144 368 Total room load 1383 1996 1440 2007 Air required (cfm) 01 91 0 91 - Calculations approved byACCAto meet all requirements of Malrival J 8th Ed. 2018-Mar-12 12:48:14 Rigli-Suite@ Unversal 2018 18.0.11 RSUI 6877 Page 7AC'C',, ... sktop\TEMP PRINT\Lot 173 Sorrento A LHG - S.rup Calc = MJ8 House faces: S LL Job: Sorrento A LH G Tr- wrightsoft' Right-J@ Worksheet Date: 03/05/2018 Entire House B y-. LF/Ri/BP/AT/MC One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling.com License: CAC032444 1 Room name T012 BEN 2 3 ExpcsedvaII Room height 7.5 ft 9.0 ft heaV000l 9.0 24.5 ft It heat/bool 4 5 R6om dimensions Room area 6.0 x 6.0 It 36.0 f? 1.0 x 137.0 112 137.0 It Ty Constructon number U-value BtuM--F) Or HTM Btj"2) Area (ft2) or perimeter (ft) Load Btuh) Area M) or perimeter (ft) Load Bbih) H eat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 I'l V[ G s 2 13A-4ocs 4A5-2om 4135-2fm 4135-21rn 4135m2fm, 097 0 850 0.143 0.550 0-140 0.540 097 5566 ne;' ne ne ne ne 3.73 14.35 14.09 14.09 35 14.09, 2.90 22.14 23.59 23.59 42!'9: 1 M 0 0 P 0 0 0 0 Izj.111 O 6 0 0 0 0 0 0 7, 0 j: 0 0 0 0 0 j" 122,"', 85 0 0 0 0 135 jq_ 11j3 04 15 0 0 0 0 7 j,,'6 89 o 0 0 0 0 i 51. 0 0 0 0 4 0 0 0 0 t-D D C F 3A-4ocs111DO 2 13A-4ocs 4A5-2om .. . ... 4A&2orn 4135-2frn 13A-4ocs 4A5-2om 4A5-2omd Osw 1 D 0 18-30I94-, 19C - torn I22A 0.143 0.390 0. 143 0.550 jbj 0.143 0.550 0.580 b.091. 0. D OK 0:04b se se sw sw AW' nw nw nw 3.73 10.18 3.73 14.35 53 1435 3.73 14.35 15.14 238 0. 1 i1108 84 0:44 30.80 2.90 12.27 2.90 21.42 2214 2.90 22.14 27.72 12-27 1 .76 0.3f 0.00 0 0 R, 4 0 0 p b 0 0 0 0 0 C) 36 36 0 0 0 114 0 0 b 0 0 0 0 0 36 Zg 0 0 0 0 0 0 0 0 0 0 0 0 0 30 f6 0 0 0 0 0 0 0 0 0 0 0 63 0 1 0 0 0 0 b 0 0 0 7 22 0 0 0 0 0 0 0 0 o 0 0 0 4 0 0 0 0 0 0 0 0 0 0 114 7,10 0 0 0 0 0 0 0 0 6 0 41 7 0 ., 61 c) AED excursion 1 411 39 Envelope loss/gain 286 4201 929 1234 12 a) Infiltration 110 40 361 130 b) Room ventilation 0 0[ 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 397 460 1290 1595 Less exL-maI load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 98 536 14 Subtotal 397 460 1387 2130 15 Ductloads 11%j 22%1 44 103 11% 22%1 1541 478 Total room load 441 563 15411 2609 Air required (dm) 0 261 0 1 818 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Mar-12 12:48:14 Rigli-SLite@Uriversa]201818.0.11 RSU16877 Page 8 sktop\TEMP PRIVRI-ot 173 SorrentoA LHG - S.rulo Calc = MJ8 House faces: S wrightsoft, Rig ht-J@ Worksheet Job: SorrerTto A LH G Entire House Date: 03/05/2018 By. LFRUBIPAPMC One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: wwwOrieStopCoolir)g.com License: CAC032444 1 Room name LOFF STC2 2 E)posed vall 12.0 It 15.5 ft 3 Room height 9.0 ft heakool 9.0 ft heat/bool 4 Room climendons 1.0 x 191.0 It 4.5 x 11.0 ft 5 Room area 191.0 Jt2 49.5 ft' Ty Construclion U-value Or HTM Area (ft) Load Area (ft2) Load number l3tuh/ft2-fl BtuhAP) or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat cool 6 Z1'28'sw 7, rie 2.,58 b 0 99 4A5L26M 550 n e 14.35 0 0 0 540 ne, 14.09 0 56 13A-4o. 0.143 ne 3.73 2.90 0 0 0 0 0 0 0 1 4A5-2om 0.550 ne 14.35 22.14 0 0 0 0 0 0 0 0 4135-2frn 0.540 ne 14.09 23.59 0 0 0 0 0 0 0 0 4135-2fm 0.540 ne 14.09 23.59 0 0 0 0 0 0 0 0 A/ "'Y 2E Osxm 0:097 7 2 82 0 6 0 b 0' 0 4 0 550 Fl-'V" 14 35 21142 0." 0 b 0 413 V,,se, 1 4.09 21 bb 0 0 0 0 I-D 3A-4o cs 0.143 se 3.73 2.90 0 0 0 0 0 0 0 011DO0.390 se 10.18 12.27 0 0 0 0 0 0 0 0 W Sw 11 2 2-8 0 0 0, i-,, ""' : .6' 0 t-G 13A-4ocs 0.143 sw 3.73 2.90 0 0 0 0 0 0 0 0 4A5-2om 0.550 sw 14.35 21 2 0 0 0 0 0 0 0 0 O'.OW n' w' 74 I . 82 10 1 it 04 4A5-,2orn 0 550 nw 435 22.14 0 0 0 0 413572h 0540 J`11-;?;;I 7, 4 6 O'j":; 0 PO 13A-4ocs 0.143 nw 3.73 2.90 0 0 0 0 0 0 0 0 4A5-2om 0.550 nw 14.35 22.14 0 0 0 0 0 0 0 0 4A5-2.md 0.580 nw 15.14 27.72 0 0 0 0 0 0 0 0 0091 2-w l'.51, O 0 0 b 1.1. bol:- 0.390 n iO.18 2 27 0 0 0 0 O O C 1613-30ad 0.032 0.84 1.76 191 191 160 336 50 50 41 87 C 119 - gcsqo 0.049 b.44 0.311 3 3 1 A 0 F 22A-tiDm 1.180 30.80 0.00 0 0 0 0 0 0 0 0 4 e 6 C) AED excursion 191 22 Envelope lossigain 480 743 441 1 541 12 a) Infiltralion 177 64 228 82 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 657 807 669 624 Less e)dernal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 764 669 624 14 Subtotal 1421 1963 0 0 15 Ductloads 11%1 22%1 157 440 11% 1 0 0 d 1 1579 2403 0 0 Air required (cIm) 0 109 0 0 Calculations aDoroved bv ACCA to meet all recuirements of Manual J 8th Ed. Fi- 2018-Mar-12 12:48:14 Right-Suite(bl-Jnversa12018 18.0.11 RSU16877 Page 941--C-11,, sktop\TEMP PRINT1ot 173 Sorrento A LHG - S.rup Calc = MJ8 House faces: S I L- Job: Sorrento A LH G rFr wrightsoft* Right-J@ Worksheet Date: 03/05/2018 Entire House By. LF/RI/BP/AT/MC One Stop Cooling and Heating 7225 Sandscove Cou L Winter Park, FL. 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wmuOneStopCooling.corn License: CAG032444 1 Room name 2 Exposed vall 0 It 4.5 It 3 Room height 9.0 ft heaV000l 9.0 It heat/cool 4 R6om dimensions 2.5 x 3.0 It 4.5 x 4.5 ft 5 Room area 7.5 112 20.3 112 Ty Construction number U-Vajue Btuh/If-09 or TM Area (ft) or perimeter (ft) Load Btuh) Area . (ft2) or perimeter (ft) Load Stuh) Gross I N/P/S Heat I Cool Gross I N/P/S Heat Cool 6 rl2B-.OMI 13A-4ocs 1 4A5-2onn 4135-2fm 4B5-2fm 0 3A-4ocs1-0 Ill Do w 13A-4ocs 4A5-2om 4A5-2omd 0.143 ne 3 " 73 2.90 0.550 ne 14.35 22.14 0.540 ne 14.09 23.59 0.540 ne 14.09 23.59 6g07,', 2 0 2142 540 4.09 1'90 0.143 se 3.73 2.90 0.390 se 10.18 12.27 0.'O 7 28 0.143 sw 3.73 2.90 0.550 sw 14.35 21.42 b 097, 2S3 0 4.35' P.4 14.091 23.59 0.143 rnN 2 90 0.550 nw 14.35 22.14 0.580 nw 15.14 27.72 2:38 E51; 0.032 0.84 1.76 0 0.44 I'll w.80 0.00 0 0 0 0 0 0 0 0 0 0 0, 0 0 0 0.. 0 0 0 0 0 0 0 0 0 0 0 0 0. 7 36 0 0 61 c) AED excursion 1 11 37 Envelope loss/gain 10 151 119 113 12 a) Infiltration 0 0 66 24 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 4 920 Appliances/other 0 1 01 Subtotal (lines 6 to 13) 10 15 186 1057 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 15 186 1057 14 Subtotal 0 0 0 0 15 Duct loads 1 1 0 0 1l%i 22% O-L-0 Total room load 0 0 0 0 Air required (cfm) 0 01 1 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2018-Mar-12 12:48:14 Rigli-SuteO Unversal 2018 18.0.11 RSUI 6877 Page 10 ACC'%, ... sktop\TEMP PRIN-RI-ot 173 Sorrento A LHG - S.rLp Calc = W8 HoLse faces: S Job: Sorrento A LH G rF wrightsoft, Right-JO Worksheet Date: 03/05/2018 Entire House 8 LF/RI/BP/AT/MC One Stop Cooling and Heating 7225 Sandscove CourtMinter Park, FL32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: wmuOneStopGooling.com License: CAC032444 1 Room name BTI-12 2 Exposed %all 0 It 3 Room height 9.0 It heat/bool 4 Room dimensions 6.0 x 5.5 It 5 Room area 33.0 It' 77 FConslrucbonnumber U-\ralue PuNft-fl or HTM BtuhV) Area OF) or perimeter (ft) Load Bbih) Area or perimeter Load H eat I Cool 1 Gross I N/PS Heat I Cool 1 Gross I N/P/S Heat I Cool 13A-40cs 0.143 ne 3.73 2. 4A5-2om 0.550 ne 14.35 22.1 4B5-2fm 0.540 ne 14.09 23. 4B5-2fm 0.540 ne 14.09 231 12 M ZE 0:550 A 0.540, se 1 3A-4ocs 0.143 se 3.73 2. 11DO 0.390 se 10.18 12.2 13A-4ocs 0.143 sw 3.73 2. 4A5-2om 0.550 sw 14.35 21 4 0 ' 097 nw, 4A5-26m:':'"'.""' 1435 22.1 4B5-2fm''-::. 0 -546 0.143 nw 3.73 2. 4A5-2om 0.550 nw 14.35 22.1 4A5-2omd 0.580 nw 15.14 27.-j 0 i bo' Q. 1 2- 16B-30ad 0 032 0.84 1.5 z:1 9q... i gcscp,-. 1' 0.4 22A-tom 1.180 30.8( 0.( 0 61 c) AED excursion 2 Envelope loss/gain 40 64 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0, Applianoes/other 0, Subtotal (lines 6 to 13) 40 41 Less external load 0 0 Less transfer 0 0 Redistribution 3 4 14 Subtotal 42 68 15 Ductloads 11% 22% 5 15 Total room load 47 84 Air required (dm) 01 41 Calculationsaonroved bvACCA to meet all requirements of Manual J 8th Ed. 4- 2018-Mar-12 1248:14 Riglht-SLjte@ Uriversal 2018 18.0.11 RSUI 6877 Page 11ACC'%, ...sktop\TEMP PRIN-R-ot 173 SorrertoA LHG - S.rulo Calc = VJ8 House faces: S wrightsofta Static Pressure and Friction Rate Entire House One Stop Cooling and Heating 7225 Sardsccve Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: whwOneStopCooling.corn License: CAC032444 Job: Sorrento A LH G Date: 03/05/2018 By. LF/RI/BP/AT/MC grojecutp,.1 ong R, M RON % -K "0 For: Park Square Homes FL Heating Cooling in H20) (in H20) External static pressure 0.50 0.50 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 0.34 Total length 241 0 Total effective length 241 Heating Cooling i n/1 00ft) (in/1 00ft) Supply Ducts 0.141 OK 0.141 OK Return Ducts 0.141 OK 0.141 OK M— 1-11 W"A -1, 'rA41-1 gg— ggng IMF IRWIN E nWNI '' "" ' ' Q ng-Elbi, it,11,121-eh 1"I dtail' Igg"I M"I" MIMI - 4P -NEU, 057,, Mg Supply 4X--35, 11 A=20, 11 J=1 5, 11 G--5, 11 G=5, 11 G=5, 11 G=5, 11 M=20, 11 G=5, 11 G--5, 11 G=5, 11 G--5, USR1 =55: Total EL=1 85 Return TotalEL=O wrightsoft* 2018-Mar-1212:48:16 Rig [I-Sijte@ Universal 2018 1M.11 RSU16877 Page I ACCK sktop\TEMP PRIN-Mot 173 Sorrento A LHG - S.rLp Calc = MJ8 HoLse faces: S r- - - 1 - -- I.- . I 1 1. - wrightsoft. Duct System Summary Entire House One Stop Cooling and Heating 7225 Sand scove Cou- Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: wwwOreStopCoolirg.com License: CAC032444 External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H20 0.16 in H20 0.34 in H20 0.170 /0.170 in H20 0.141 in/100ft 0 cfm 241 ft Job: Sorrento A LH G Date: 03/05/2018 By. LF/R1/BP/AT/MC Cooling 0.50 in H20 0.16 in H20 0.34 in H20 0.170 /0.170 in H20 0.141 in/1 00ft 1160 cfm ORIQ MF- CMD'SamAg8rah," dolDd 11-11 AMR@j; p ply_ Name Design Btuh) Htg cfm) Clg cfm) Design FR Diarn i n) HxW in) Duct Matl Actual Ln (ft) Ftg.Eqv Ln (ft) Trunk BED2 c 1996 0 91 0.225 6.0 ox 0 A Fx 26.1 125.0 st6 BED3 c 2007 0 91 0.214 6.0 Ox 0 M Fx 24.1 135.0 st6 BED4 c 2609 0 118 0.233 6.0 Ox 0 MFx 25.7 120.0 st6 BTH2 c 84 0 4 0.258 4.0 Ox 0 M Fx 16.7 115.0- st6 DINE c 1036 0 47 0.167 5.0 Ox 0 MFx 33.1 170.0 st5 GRT c 5289 0 240 0.157 8.0 Ox 0 MFx 41.5 175.0 st5 KIT c 2104 0 96 0.177 7.0 Ox 0 AFx 32.1 160.0 st4 LNDY c 1177 0 53 0.184 5.0 Ox 0 MFx 24.6 160.0 st4 LOFT -A c 2403 0 109 0.240 6.0 Ox 0 MFx 21.6 120.0 st6 MBED c 3783 0 172 0 " 141 8.0 Ox 0 MFx 6.2 185.0 st5 MBTH c 1152 0 52 0.145 5.0 Ox 0 M Fx 54.5 180.0 st5 MT01 c 44 0 2 0.151 4.0 Ox 0 MFx 45.6 180.0 st5 MWIC-A c 224 0 10 0.149 4.0 Ox 0 MFx 43.0 185.0 st5 PWDR c 1073 0 49 0.168 5.0 Ox 0 AFx 37.1 165.0 s14 T012 c 563 0 26 0.229 4.0 Ox 0 AFx 23.3 125.0 st6 wrightsoft, 2018-Mar-12 12-.48:16 Rigfi-Suite@ Universal 2018 18.0.11 RSU1 6877 Page 1 CCK ...sktop\TEMP PRINT\Lot 173 Sorrento A LHG - S.rLp Calc = MJ8 HoLse fares: S Name Trunk Type Htg Cfm) CIg Cfm) Design FIR Veloc fpm) Diarn in) HxW in) Duct Material Trunk st4 PeakAVF 0 198 0.168 566 8.0 0 x 0 VinIFIx st3 st3 PeakAVF 0 198 0.168 252 12.0 0 x 0 VinlFIx st2 s12 PeakAVF 0 721 0.141 675 14.0 0 x 0 VinIFIx sti st-I PeakAVF 0 1160 0.141 656 18.0 0 x 0 VinIFIx st5 PeakAVF 0 524 0.141 667 12.0 0 x 0 VinIFIx st2 s16 PeakAVF 0 439 1 0.214 559 12.0 0 x 0 VnIFIx sti Name Grille Size (in) Htg Cfm) Cig Cfm) TEL ft) Design FR Veloc fpm) Diarn in) HxW in) Stud/Joist Opening (in) Duct Mal Trunk_ rbl Ox 0 0 1160 0 0 0 0 Ox 0 VlFx wrightsoft, 2018-Mar-12 12:48:16 Rigft-SJte@ Uriversal 2018 18.0.11 RSU1 6877 Page 2 ACCK sktop\TEMP PRINT\Lot 173 Sorrento A LHG - S.rLp Calc = MA HoLse faces: S I DV VTW Job#: Sorrento A LHG Performed by LF/RI/BP/AT for: Park Square Homes Level 1 One Stop Cooling and Heating 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407). 629 - 9307 www.OneStopCooh ng.corn 1 OX6 52 cfm I EF1 VTW I Scale: 1 :58 Page 1 Comfort BuOder by WrightsDft 18.0.10 RSU30040 2018-Feb-06 14:30:26 I A A-tZ 9 4A RF-CORD Copy tl/\)O#fiy), rxa 3twijcz, C rO c) Z 7?9 ArV x 1.8- 1392 3 4( j bi. - RECORD COPY I DESCRIPTION AS FURNISHED: Lot 173, WYNDHAM PRESERVE,* as recorded in Plot Book 81, Pages 93 through 102 of the Public Records of Seminole County, Florida. PLOT PLAN FORICERTIFTED TO: Park Square Enterpris"es, LLC (a Delaware Corporation); Winderweedle, Haines, Word & Woodman, PA; Attorneys' Title Insurance Fund; Bank of America 6\0 (9_13CJ'Z, LOT 163 NIN W DATE_q_Llt Ok to construct single family home with setbacks and impervious area shown on plan. 5*3 - 5 "1. i-m(a. LOT 172 P. C. 196.00 SETBACKS AS FURNISHED FRONT 25'(*) REAR 20' SIDE 5' (40' LOT) 7.5' (60' LOT) 10' (75' LOT) SIDE STREET = 25' (60' & 75' LOT) 15' (40' LOT) 25- FRONT SETBACK CAN BE REDUCED TO 20' ON CERTAIN LOTS. NO MORE THAN 2) IN SUCCESSION AT 20' AND A MINIMUM OF (2) IN SUCCESSION AT 25' PROPOSED = FINSHED SPOT GRADE ELEVATIONS PER DRAINAGE PLANS PROPOSED DRAINAGE FLOW LOT GRADING TYPE A PROPOSED F.F. PER PLANS = 30.5' 5.00' 5.00' Pq 5.00' LOT 162 LOT 161 N89040'51 'E 40,00' 20.00' 20.00' P, — 5.00, 14 7' LANAI 3. O'x4. 0' 15.3' AC PROPOSED RESIDENCE 2078—SORRENTO—A 2 CAR GARAGE LEFF Uiin LOT 173 U') COVD. ENTRY 9.3' 20.7' 16' L DRIVE WADLK 25.00' 5. 00' 10' UTIL. ESMT. WALK CURBI \ B.B.) N89*40'51':E 40. 00,' LZI 5. 00' SALTHARSH LOOP 50' PRIVATE R/W) LOT 174 PLOT PLAN ONLY PLOT PLAN AREA CALCULATIONS JVO T A SURVEY TOTAL LOT AREA 4,400 ± SQUARE FEET FLATWORK ONIOFF LOT = TOTAL ± SQUARE FEE]' FLATWORK DRIVE 4001 1 10= 5;10 ± SQUARE FEET FOUNDATIONIPAD 1,744 ± SQUARE FEET WALKS 371 200= 2j7 ± SQUARE FEET REAR PATIO 112 ± SQUARE FEET FRONT PORCH DECK 62 ± SQUARE FEET SOD 2,0331 130 = 2, 1'63 ± SQUARE FEET POOL DECK NIA ± SQUARE FEET NOTE., FRONT SIDEWALK AND STREET LOCATION TAKEN FROM PLANS PROWDED BY CLIENT - NOT FIELD VERIFIED - CRUSEiVHEYER -SCOTT NK ASSOC, INC - IAND SURVZ,1,yU-HS LEGEND - LEGEND - 5400 E. COLONIAL DR. ORLANDO, FL. 32807 (407)-277-3232 FAX (407)-658-1436 P PLAT PJD.L' POINT ON LINE NOTES: FIP FIELDIRON PIPE TYP. PRIC TYPICALPOINTOF REVERSE CURVATURE 1. THE UNDERSIGNED DOES HEREBY CERTIFY THAT THIS SURVEY MEETS THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF IR: IRON ROD PZ.C: POINT OF COMPOUND CURVATURE APT -17 FLORIDA ADMINISTRATIVE CODE PURSUANT TO SECTION 472.027, FLORIDA STATUESPROFESSIONALSURVEYORSANDMAPPERSINCHER5J C M. CONCRETE MONUMENT RAD. RADIAL 2. UNLESS EA48OSSED WITH SURVEYOR'S SIGNATURE AND ORIGINAL RAISED SEAL, THIS SURVEY MAP OR COPIES ARE NOT VALID. Si I I.R. 1/2' I.R. ./NLB 4596 NJR. V.P. NON- ADIAL WITHIE'SS POINT J. THIS SURVEY WAS PREPARED FROM TITLE. INFORMATION FURNISHED TO THE SURVEYOR. THERE MAY,&E OTHER RESTRIC71ONS REC. PP:,O:C,: RECOVERCD PO NT OF B ' IN NOPOINTK151111''EN'CIZMEIII ALC. C.. P CALEULATED PER ANENT REFERENCE MONUMENT OR EASEMENTS THAT AFFECT T141S PROPERTY. 4 NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED UNL_ESS OTHERWISE SHOWN. CENTERLIME FF. F1 NIS14ED FLOOR ELEVATION 5. THIS SURVEY IS PREPARED FOR THE SOLE BENEFIT OF THOSE CERTIFIED To AND SHOULD NOT BE RELIED UPON BY ANY OTHER ENTITY. NLD NAIL L DISK B.S.L. 0 UILDING SETBACK LINE 6. DIMENSIONS SHOWN FOR THE LOCATION OF IMPROVEMENTS HEREON SHOULD NOT BE USED TO RECONSTRUCT BOUNDARY LINES. R/W R IGHT-OF- AY DIM BE NCHMARK BASE BEARING 7. BEARINGS, ARC BASED ASSUMrO DATUM AND ON THE UNC SHOWN AS BASE BEARING (O.B.) E SMT. DRAIN, EASEMENTDRAINAGE 8. ELEVATIONS, IF SHOWN, ARE 11ASED ON NATION AL GEODETIC VERTICAL DATUM OF 1929. UNLESS OTHERWISE NOTED. UTIL. UTILITY FENCE 9. CERTIFICATE OF AUTHORIZAT70N N.. 4596. CL.FC. CHAIN Ll D.FC. By.. WOOD FENCE B CONCRETE BLOCK SCALE P CT: POINT OF CURVATURE ORDER N.. POINT OF TANGENCY DATE DESC. DESCRIPTION CERTIFIED BY. - 18 R RAD IUS PLOT PLAN 03-07-2018 1327 L ARC L NGTH D DELTA C CHORD C.D. CHORD BEARING NORTH THIS BUILDING\PROPERTY DOES NOT UE 'IN T ESTABLISHED 100 YEAR FLOOD PLANE AS PEI ' T R._ TO ICIE1. R. L, s9t HE I 'F JAM SCOTT, 7S 1 4801 BZONE "XI MAP I 12117CO090 F 09-2 -07) I Fiiename: PARK SQUARE SORRENTO 2,078SF.rrr RECORD COPY Lighting and Small Appliance/Laundry Circuits Floor Area SmAppNo LaundNo Line Neutral 2 2 1 Lighting Summary Standard 3,527 3,527 Optional 4,506 3,527 R-a-n-g-e-s--&--O-v-e-n-s Range No. No? Nameplate Line Neutral 8000 2 0 0 3 0 0 Range/Oven Summary Standard 6,400 4,480 Optional 8,000 4,480 Dryers BU14,0DryerNo. No? Nameplate Line Neutral 5000 0A 2 0 3 0 3 9 2DryerSummaryStandard5,000 3,500 Optional 5,000 3,500 Heating and Cooling: Actual Number 2 Name M? Ph No Amps Volts VA HP Line Neutral M 1 1 14.0 240 3,360 0 M 1 1 2.0 240 480 0 1. M 1 1 5.0 240 1,200 0 1 1 1 1 14 240 1 3,360 0 M 1 1 14.0 240 3,360 0 2 M 1 1 2.0 240 480 0 2 M. 1 1 5.0 240 1,200 0 2 1 1 1 14 240 1 3,360 0 H at/Cool Summary Standard 16,800 0 Optional 16,800 0 Fixed Appliances: Actual Number 6 Name M? Ph No Amps Volts VA HP Line Neutral DISP 120 600 600 600 DISH 120 1200 1,200 1,200 MICRO- 120 1200 1,200 1,200 WH 1 1 18.5 240 4,440 0 OPT POOL 1 1 10 240 2,400 0 OPT POOL HEAT 1 1 31 240 7,440 0 Fixed Appliance Summary Standard 12,960 2,250 Optional 17,280 2,250 other Appliances: Actual Number 0 Name M? Ph No Amps Volts VA HP Line Neutral Other Appliance Summary Standard 0 0 Optional 0 0 I 25% of Max Motor: Line is Std Only; Neutral for Both Maximum Phase Amps Volts 1 14 240 Heat/Cool Phase Amps Volts 1 14 240 Fixed Appl. Phase Amps Volts 0 Other Appl. Phase Amps Volts 0 Max Motor Summary Standard only 840 0 SUMMARY Standard Line Neutral Total Total 45,527 13,757 Maximum Amperage 190 57 Service Voltage = 240 Service Phase = 1 Optional Line Neutral Total Total 36,714 13,757 Maximum Amperage 153 57 Service Voltage = 240 Service Phase Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. RECORD COPY RE: P2078AC-T - Park Sq Hms/ Sorrento-AorC 2078 MiTek USA, Inc. 6904 Parke East Blvd. Site Information: 6 Customer Info: PARK SQUARE HMS. Project Name: P2078AC-T Model: SORRENT 727'8'A'o'r e-Nr4y CIg. Lot/Block: 173 Subdivision: WYNDHAM PRESERVE 40' Address: 3917 SALTMARSH LOOP City: SANFORD State: FLORIDA Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #-. Address: City: State. - General Truss Engineering Criteria & Design Loads (individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 140 mph Roof Load: 40.0 psf Floor Load: 55.0 psf This package includes 49 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# JTruss Name Date No. I Seal# Truss Nam I Date 11 IT12944419 lAl 11/12/18 112 1 T1 2944430 1 B6 11/12/18 12 T`129444 0 lAlT 11/12/18 113 IT12944431 IC1 11/12/18 13 IT12944421 I A2T 11/12/18 114 IT12944432 JC2 11/12/18 1 14 IT12944422 I A3T 11/12/18 115 IT12944433 JC3 11/12/18 15 IT12944423 IA4T 11/12/18 116 IT12944434 ICJ 11/12/18 16 IT12944424 IA5T 11/12/18 117 IT12944435 ICJ1 11/12/18 1 17 IT12944425 IB1 11/12/18 118 IT12944436 ICJ3 11/12/18 1 18 IT12944426 IB2 11/12/18 119 IT12944437 ICJ3T 11/12/18 J 19 IT12944427 IB3 11/12/18 120 IT12944438 ICJ4 11/12/18 1 110 IT12944428 IB4 11/12/18 121 IT12944439 ICJ5 11/12/18 1 I'll IT12944429 JB5 11/12/18 122 IT12944440 ICJ5T 11/12/18 1 This item has bee ally signed and sealed by Magid, Michael, PE using a Digital Signature. cl call c tu'M e tPrintedcopieso ?h i §`16 c' "M)e are not considered signed and sealed and the signature must be verified on anyc electronic copi s ANFORD 3492 Z PA RI\' # The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Mid -Florida Lumber Acquisitions, Inc.. Truss Design Engineer's Name: Magid, Michael My license renewal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and property incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. STATE 0 F 44/ C) W,;_px MiTekUSAJI FRLCe 634 6904 Parke East Blvd. Tampa FL 33610 Date: January 12,2018 Magid, Michael I of 2 RE: P2078AC-T - Park Sq Hms/ Sorrento-AorC 2078 Site Information: Customer Info: PARK SQUARE HMS. Project Name: P2078AC-T Model: SORRENTO - 2078 Aor C / Tray CIg. Lot/Block: 173 Subdivision: WYNDHAM PRESERVE 40' Address: 3917 SALTMARSH LOOP City: SANFORD State: FLORIDA No. Seal# Truss Name I Date 123 IT12944441 JD1 11/12/18 124 IT12944442 ID2 11/12/18 125 IT12944443 ID3 11/12/18 1 126 IT12944444 lEl 11/12/18 127 IT12944445 JE2 11/12/18 128 IT12944446 JR 11/12118 129 IT12944447 IF2 11/12/18 1 130 IT12944448 IF2A 11/12/18 131 IT12944449 JF3 11/12/18 132 IT12944450 JF3G 11/12/18 133 IT12944451 IF4 11/12/18 134 IT12944452 IF4A 11/12/18 1 135 IT12944453 IF5 11/12/18 136 IT12944454 I FE3 11/12/18 137 IT12944455 JF7 11/12/18 1 138 IT12944456 IFT1 11/12/18 1 139 IT12944457 IFT2 11/12/18 1 140 IT12944458 JFT3 11/12/18 141 IT12944459 IFT4 11/12/18 142 IT12944460 JJ3 11/12/18 143 IT12944461 P 11/12/18 1 144 IT12944462 IJ7T 11/12/18 145 IT12944463 IKJ2 11/12/18 146 IT12944464 IKJ3 11/12/18 147 IT12944465 IKJ7 11/12/18 148 IT12944466 JKJ7T 11/12/18 149 IT12944467 IM1 11/12/18 1 2 of 2 Job T ss ype Qty Pa Hms/ Sorrento-AorC 2078 FCOUSMSMT T12944 9rP2078AC-T At ON 6 ry 1 Job RSeqferen Mid-Floncla Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek industries, Inc. Fri Jan 12 07 49 00 2018 Page 1 ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-HoWSyHE3CoX]YWbbOp2GfP4vaCw3LyeTYIABlpzwgon 7-11-11 15-M 22-0-5 30-0-0 7-11-11 7-0-5 7-0-5 7-11-11 1-0-0 4 Scale = 1:53.5 4X4 4x4 = 6.00 F12 3x4 = 4x6 — 3x4 10-2-3 19-9-13 30-0-0 10-2-3 9-7-11 10-2-3, 4X4 = LOADING (psf) SPACING- 2-0-0 CS1 ' DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.75 Vert(LL) 0.35 8-10 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.76 Vert(CT) 0.50 10-13 721 180 BCLL 0.0 Rep Stress Incr YES WB 0.34 Horz(CT) 0.06 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 137 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOTCHORD 2x4SPNo.1 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1260/0-8-0, 6=126010-8-0 Max Horz 2=1 64(1-C 11) Max Uplift 2=-328(LC 12), 6 328(1-C 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2096/624, 3-4=-1893/637, 4-5 1893/637, 5-6=-2096/624 BOTCHORD 2-1 o=-441/1873, 8-1 0=-20511211, 6-8=-45511821 WEBS 4-8=-217/820, 5-8=-467/270, 4-10 217/820, 3-10=-467/270 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc puffins. BOTCHORD Rigid ceiling directly applied or 9-1-5 oc bracing. NOTES- 1) Unbalanced roof live loads have been Considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf, bCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; M\AIFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interion(l) 2-0-0 to 15-0-0, Exterior(2) 15-0-0 to 18-0-0 zone,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=328,6=328. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARAIING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE mli-7473re, 1010312015 BEFORE USE. Design valid for use only with MiTelk@ connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must venfy the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse wilh possible personal injury and property damage. For general guidance regarding the 10 OUR, fabdcatign, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 69G4 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Streel, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job T ss Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944420 P2078AG-T AlT SPECIAL I Job Referenc mia-t-ionaa LUMDer, tsanow, 1-L. .. ". . —P .' — i , -.' — I . .1. . . - - ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-1-3q9dEhz6f9AgAnaXZVCdd34cFA4MHcmywkHFzw9om Ii-0 2 7 7-4-0 12 8 15,0: 19-9-11 4-7-" 30-0-0 i I _0_) 2 4-8-8 4-9-13 5-4-5 1-M4" Scale = 1:55.9 5x8 2.4 11 4X14 — 13 12 1 . 5x4 11 1.5X4 3x10 3X4 4x4 270 7-4-0 '1 2 - D8 22-2-12 30-0-0 2-12 -942-51 4-8-8 4, 1,_8 7 7 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) 0.19 15-21 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.83 Vert(CT) 0.39 15-21 908 180 BCLL 0.0 Rep Stress Incr YES WB 0.57 Horz(CT) 0.22 9 nia n1a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER- TOPCHORD 2x4 SP No.2 *Except* 1-3: 2x6 SP No. 1 BOTCHORD 2x4 SP No.2 *Except* 2-14: 2x6 SP No. 1, 4-13: 2x4 SP No.3 WEBS 2x4 SP No.3 OTHERS 2x6 SP No.1 LBR SCAB 1-3 2x6 SP No. 1 one side REACTIONS. lb/size) 1=1204/0-8-0,9=1249/0-8-0 Max Harz 1 162(1_C 10) Max Uplift 1 276(1_C 12), 9=-325(LC 12) DA 6 PLATES GRIP MT20 244/190 Weight: 200 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 3-7-10 oc puffins. BOTCHORD Rigid ceiling directly applied or 8-3-10 oc bracing. FORCES. (lb) -Max. Cam p./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-545/195, 2-3=-2793/796, 3-4 1 944/613, 4-5 1 891/670, 5-6 1 395/505, 6-8=-2014/619, 8-9=-2213/648 BOTCHORD 2-15 608/2552, 14-15 606/2531, 11-12=-357/1565, 9-11 =-501/1945 WEBS 3-15 52/407, 3-14=-989/319, 12-14=-165/1157, 5-14=-353/1191, 6-12=-560/245, 6-11 =-85/451. 8-11 =-297/165 NOTES- 1) Attached B-6-3 scab 1 to 3, front face(s) 2x6 SP No. 1 with 2 row(s) of 1 Od (0. 131 "x3") nails spaced 9" o.c.except : starting at 1-11-3 from end at joint 1, nail 2 row(s) at 2" o.c. for 2-8-6. 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf, h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18, M\A(FRS (directional) and C-C Exterior(2) 0-4-0 to 3-3-0, Interior(l) 3-3-0 to 15-0-0, Exterior(2) 15-0-0 to 18-0-0 zone;C-C for members and forces & M\1VFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSIrrP1 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 1=276,9=325. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473 rev. 1010312015 BEFORE USE Design valid for use only with MTeke connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must venfy the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is atways required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 10 OR, fabrication, storage, delivery, erection and braung of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Adexandria, VA 22314. Tampa, FL 36610 Job Trus Truss Type Qty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944421 P2078AC-T A2T SPECIAL I Job Reference (optional) Mid-Fiorida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Jan 12 07:49:02 2018 Page I ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-DAdCNzFJjQnOnq_8E4kkqgDgCbTpigm?cfHqizwgoI 02-V 7-4-0 L2,:2:8 310 17-0 2-,1,2 30-0-0 1-0-9 2_ _ _: 9 i3_ i 30. 4-8-8 4 , _ 1 -8 4-0-0 i 6-2_ 6-94 1 -M 4X4 6-oo 5_2 4X8 4 27 28 5 2X4 11 4x14 2x4 11 12 11 10 9 1X4 1 X4 11 3xl 0 1.4 1.4 7-4-0 2 8 17 001 23-2-12 30-0-0 2-l It- 1 4-1-1 4 rl 1 :1 4 6-2-12 6-9 4 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.84 TCDL 10.0 Lumber DOL 1.25 BC 0.82 BCLL 0.0 Rep Stress Incr YES WB 0.82 BCDL 10.0 Code FBC2017fTPI2014 Matrix -MS LUMBER- TOPCHORD 2x4 SP No.2 *Except* 1-3: 2x6 SP No. 1 BOTCHORD 2x4 SP No.2 *Except* 2-13: 2x6 SP No.1, 12-16: 2x4 SP No.3 WEBS 2x4 SP No.3 OTHERS 2x6 SP No.1 LEIR SCAB 1-3 2x6 SP No.1 one side DEFL. in (loc) I/defl L/d Vert(LL) -0.19 14-21 >999 240 Vert(CT) -0.39 14-21 >909 180 Horz(CT) 0.22 7 n/a n/a Scale = 1 56.0 4x4 = PLATES GRIP MT20 244/190 Weight: 195 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 3-5-15 oc puffins. BOTCHORD Rigid ceiling directly applied or 8-1-8 oc bracing. REACTIONS. (lb/size) 1=1215/0-8-0 7=1257/0-8-0 Max Horz 1 142(1_C 10) Max Uplift 1 273([_C 12), 7 323([_C 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-536/200,2-3=-2826/830, 34 1893/623, 4-5 1609/593' 5-6 1605/553, 6-7=-2216/666 BOTCHORD 2-14=-644/2588, 13-14 642/2569, 9-10=-513/1919, 7-9=-513/1919 WEBS 3-14=-34/416, 3-13=-1064/361, 4-13=-146/561, 6-10=-6501260, 6-9=0/284, 10-13=-29211373, 5-13 106/4911 NOTES- 1) Attached 8-6-3 scab 1 to 3, front face(s) 2x6 SP No. 1 with 2 row(s) of 1 Od (0. 1 31"x3") nails spaced 9" o.c.except: starting at 3-8-12 from end at joint 3, nail 2 row(s) at 2" o.c. for 2-8-6. 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf, h=25ft; B=45ft; L=30ft, eave=4ft; Cat. 11; Exp B; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-3-0, Interior(l) 3-3-0 to 13-0-0, Exterior(2) 13-0-0 to 20-G-0, Interior(l) 20-0-0 to 31-0-0 zone:C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-G-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 1=273,7=323. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE WII-7473 re 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indiidual truss web and/or chord members only. Additional temporary and Penmanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabricalion, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Thus Truss Type City Ply Park Sq Hms/ Sorrento-AorC 2078 T12944422 A3T SPECIAL 1 all tvlo-f,ionaa LumDer, banow, I-L. 0'' ou 5 07P I D U I I IVII I eK IFIUU5UI 5, I I 1U. r I I Jdl I I Z U/.ffU.UJ ZU 10 rdy I ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-hNBbaJGxUjvtP_KAjybzH2iPZQxtYGSvEGPrM8zw9ok 2-1: 11 2 19-0-0 24-2-12 10-09- 1 11-0-0 T 11144-2 4-21 6-11-8 5-2-12 Scale = 1:52.2 6Do 5_2 RFFFR TO N()TF *1 5X5 = 1.5X4 11 4X8 4 5 26 27 28 29 6 2X41 11 1— — 12 11 10 1 X4 11 3X4 11 5x8 1 X4 11 4x4 9 l2 o 2-o-81 19-0-0 N '_1 2111:i 6-11-82- H-8 4-2 12 1-9-40 Plate Offsets MY)— [2:0-7-8,0-1-41, [3:0-2-14,0-3-41, [4*0-2-8.0-2-41, [6:0-5-4,0-2-01, [13:0-2-8,0-2-121, [17:0-0-14,0-1-41 LOADING (ps" SPACING- 2-G-0 CS1. DEFL. in (loc) I/defl L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) 0.20 14-20 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.81 Verl(CT) 0.40 14-20 894 180 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(CT) 0.22 8 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 1-3: 2x6 SP No.1 BOTCHORD 2x4 SP No.2 *Except* 2-13: 2x6 SP No. 1, 5-12: 2x4 SP No.3 WEBS 2x4 SP No.3 OTHERS 2x6 SP No. 1 LBR SCAB 1-3 2x6 SP No. 1 one side REACTIONS. lb/size) 1=1204/0-8-0,8=1249/0-8-0 Max Horz 1=121(LC 10) Max Uplift 1 276(!_C 12), 8 325(1_C 12) PLATES GRIP MT20 244/190 Weight: 196 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 3-2-12 oc purlins. BOTCHORD Rigid ceiling directly applied or 7-10-10 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-5301204, 2-3=-2870/870, 3-4 3046/1018, 4-5 1919/696, 5-6 1921/701, 6-7 1764/610, 7-8=-22371702 BOTCHORD 2-14=-683/2631, 13-14 423/1806, 5-13 419/215, 10-11 =-555/1946, 8-1 O 55511946 WEBS 3-14=-543/267, 4-13=-1 65/547, 11-13=-347/1380, 6-13 1 55/574, 6-11 =-12/281, 7-11 =-503/217, 4-14=-417/1255 NOTES- 1) Attached 7-11-3 scab 1 to 3, front face(s) 2x6 SP No. I with 2 row(s) of 1 Od (0. 131 "x3") nails spaced 9" o.c.except : starting at 3-1-13 from end at joint 3, nail 2 row(s) at 2" o.c. for 2-8-6. 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18 MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-3-0, Interior(l) 3-3-0 to 11-0-0, Exterior(2) 11-0-0 to 22-0-0, Interior(l) 22-0-0 t 31-0-0 zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) I considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 0=1b) 1=276,8=325. v!) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE U11-7473 —.1010312015 BEFORE USE. Design valid for use only with MiTel,11) connectors. This design is based only upon parameters shown, and is for an indivdual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see , ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, AJexandria, VA 22314. Tampa, FL 36610 Job Truss oty Ply Park Sq Hms/ Sorrento -AorC 2078 r. russ TyLpe T12944423 P2078AC-T A4T PEC A Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Jan 12 07:49:04 2018 Page 1 ID:LwgEfgAbgYkKfRKdr2TZXPzS7xJ-9ZIzofHaF1 lkl8vMFf6CpFFaJpDTHh72Sw8Ouazw9oj 12 2 8 16 4 21-0-0 2 2 0-0 1 _0: P, 0 9-0-0 -6 -12-i-,20 Oil 3-2 21 3 4-5-12 4-5-12 4-2 2 4-114 -M Scale = 1:51.3 REFER TO NOTE #1 FOR SCAB CONNECTION. 5X8 l.bx4 11 3X4 4x8 26 4 5 27 6 28 29 7 6.00 [12 3x4 600 - 12 3x4 .5 26 4 30 1.5x4 2x4 2 31 1 16 15 14 "1 9 10 ic? 6X8 X4 xt 6 8 2x4 3x4 X 13 12 11 2X4 11 1.5X4 11 2X4 4x10 3x4 3X8 12 9-O O 2 -8 16,614 21-0-0 30-0-0 1 2-1-. Qipl 12 3" 2 4-11 M-0 LOADING (ps, SPACING- 2-0-0 CS1. TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 TCDL 10.0 Lumber DOL 1.25 BC 0.98 BCLL 0.0 Rep Stress Incr YES WB 0.69 BCDL 10.0 Code FBC2017fTPI2014 Matrix -MS LUMBER- TOPCHORD 2x4 SP No.2 *Except* 1-4: 2x6 SP No. 1 BOTCHORD 2x4 SP No.2 *Except* 2-14: 2x6 SP No.2, 5-13: 2x4 SP No.3 WEBS 2x4 SP No.3 OTHERS 2x6 SP No.1 LBR SCAB 1-4 2x6 SP No.1 one side REACTIONS. (lb/size) 1=1204/0-8-0,9=1249/0-8-0 Max Horz 1=-100(LC 10) Max Uplift 1 =-276(LC 12), 9=-325(LC 12) DEFL. in (loc) I/defi L/d Vert(LL) -0.19 14 >999 240 Vert(CT) -0.39 11-25 >912 180 Horz(CT) 0.22 9 n/a n/a PLATES GRIP MT20 244/190 Weight: 202 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 3-7-7 oc purlins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-5301206, 2-3 3264/1021, 3-4 24281796, 4-5 2418/840' 5-6 2408/838' 6-7=-1941/718, 7-8 1923/651, 8-9=-2225/752 BOTCHORD 2-16 858/3068, 15-16=-858/3068, 14-15=-536/2123, 11-12 432/1669' 9-11 607/1967 WEBS 3-16=-53/295,3-15 1100/380,4-15=-171/628,4-14=-162/508,12-14=-493/1812, 6-14 154/611,6-12=-678/250,7-12=-157/473,7-11=-48/395,8-11 349/199 NOTES. 1) Attached 10-2-10 scab 1 to 4, front face(s) 2x6 SP No.1 with 2 row(s) of 10d (0.131 "x3") nails spaced 9" o.c.except : starting at 1-11-3 from end at joint 1, nail 2 Fowls) at 2" o.c. for 2-8-6. 2) Unbalanced roof live loads have been considered for this design. 3) \Arind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. 11; Exp B, Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-3-0, Interioni 3-3-0 to 9-0-0, Exterior(2) 9-0-0 to 24-0-0, Interior(l) 24-0-0 to 31-0-0 zone;C-C for members and forces & M\A1FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 1 considers parallel to grain value using ANSIfTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (=Ib) 1=276,9=325. - Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE U11-7473 re, 1010312015 BEFORE USE. Design valid for use only with MiTelke connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design paramelers and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Infortmation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss T ss Type oty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944424 P2078AC-T A5T SPECIAL 1 at) mia-t-ionaa LUMDeF, bariow, rL. ..— . —P '. '..' — -.. — .'-- '... -W . ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-dIJL??ICOL9bflUYpNeRMTnIXDhSO6tChauyQOZW9oi 2-5,0 12-M 44-0 8-1-2 1 23-0-0 2-12 -0 4 N 5-M 2 4 2 -14 V2 2 3- 0 1 Scale = 1:52.2 6.00 5_2 5X8 = 3X4 11 5X8 = 1.5x4 11 4x8 3 26 27 4 28 5 29 30 6 31 32 7 A Ic? 2X4 11 ", — 14 13 12 __ 11 1.1x4 11 1.5X4 6X6 5xii = 3x4 3x4 12- 2 1 0 02- 12-0-8 18-7-2 23-0-0 212 2 1 -Ml -_4 2_ _O 5_0 O_V8 4:i 5-M 2." 4_,2 4-4-14 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.80 Vert(LL) 0.11 16-22 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.49 Vert(CT) 0.21 115-22 809 180 BCLL 0.0 Rep Stress Incr NO WB 0.79 Horz(CT) 0.09 13 n/a n/a BCDIL 10.0 Code FBC2017rrPI2014 Matrix_MS Weight: 160 lb FT = 20% LUMBER- TOPCHORD 2x4 SP No.2 *Except* 1-3: 2x6 SP No.2 BOTCHORD 2x4 SP No.2 *Except* 4-14: 2x4 SP No.3 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=396/0-8-0, 9=669/0-8-0, 13=3116/0-8-0 Max Horz 1 80(1_C 6) Max Uplift 1 1 26(LC 8), 9=-21 1 (LC 8), 13=-945(LC 8) Max Grav 1 =404(LC 17), 9=731 (LC 18), 13=3116(LC 1) BRACING- TOPCHORD Structural wood sheathing directly applied or 5-3-8 oc purlins. BOTCHORD Rigid ceiling directly applied or 4-4-7 oc bracing. WEBS I Row at midpt 3-15 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-451/256, 34 293/1264, 4-5 310/1306, 5-6 72/301, 6-7 7213011, 7-8=-930/291, 8-9=-1 1511311 BOTCHORD 2-16=-187/412,15-16 189/438, 4-15 409/215,12-13 1708/577,11-12=-210/813, 0— 11 =-217/1012 WEBS 3-16=-121/488,3-15=-1873/578,13-15 1840/637, 5-15=-231/635, 5-13=-21251701, 7-11 80/643, 8-11 282/114, 6-12=-520/267, 5-12 606/2064, 7-12 1049/290 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf ' BCDL=3.Opsf ' h=25ft, 8=45ft, L=30ft, eave=4ft, Cat. 11; Exp 8, Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSIfTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except 0=1b) 1=126,9=211,13=945. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 109 lb down and 139 lb up at 7-0-0, 80 lb down and 91 lb up at 9-0-12, 80 lb down and 91 lb up at 11-0-12, 97 lb down and 106 lb up at 13-0-12, 97 lb down and 106 lb up at 15-0-0, 97 lb down and 106 lb up at 16-11-4, 97 lb down and 106 lb up at 18-11-4, and 97 lb down and 106 lb up at 20-11-4, and 189 lb down and 206 lb up at 2a-0-0 on top chord, and 340 lb down and 158 lb up at 7-0-0, 66 lb down at 13-0-12, 66 lb down at 15-0-0, 66 lb down at 16-11-4, 66 lb down at 18-11-4, and 66 lb down at 20-11-4, and 327 lb down and 97 lb up at 22-11-4 on bottom chord. The designiselection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (6). LOAD CASE(S) Standard Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1411-7473 re, 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the ki fabdcation , storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Trus Truss Type Qty Ply Park Scl Hms/ Sorrento -AorC 2078 T12944424 P2078AC-T A5T SPECIAL 1 1 Job Reference (optional) Mid-Flonda Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Jan 12 07:49:05 2018 Page 2 ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-dIJL??ICOL9bflUYpNeRMTn[XDhSO6tChauyQOzw9oi LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: 1-21=-82, 3-21=-60, 3-7=-60, 7-10 60, 15-20=20, 14-23 20 Concentrated Loads (lb) Vert: 3 80fl 7=-142(F) 16 340fl 1 1=-327(F) 26=-80(F) 27=-80(F) 28=97(F) 29=-97(F) 30=-97(F) 31 97fl 32 97fl 33=41(F) 34=41 (F) 35 41fl 36=-41 (F) 37=41 (F) A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PA GEMII.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTekV connectors. This design is based only upon parameters shown, and is for an indimdual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall ibuilding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracingsalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regarding the Mae I fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd, Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Truss Truss Type Qty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944425 Bi SPECIAL 1 ah M10-1-101710a LUMUeF, t5anow, I-L. ID:LwgEfgAbl'Kd'r'2"T'Z'XP'z'S' 7'x"J" '6'4'D"L'lq'n"e"H'S"G"R"21'N'4"9g'v"g'K'v'fd'w'nid'*S'L'w'E'd'V'zT'z'w9'oh' 6-7-4 12-M 184-0 20-0-0 27-0-0 7-0-01-M 6-7-4 5-8-0 1-M 4X4 = 4 3X4 3x4 3x4 3x10 = 1.5X4 3x4 LOADING (psf) SPAICING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d TCLL 20. 0 Plate: Grip DOL 1.25 TC 0.78 Vert(I-L) 0.22 10-12 999 240 TCDL 0 L.- Der DOL 1.25 BC 0.93 Vert(CT) 0.41 10-12 800 180 BCLL 0 00 Rep Stress Incr YES WB 0.57 Horz(CT) 0.06 7 n/a n/a BCDL 10.0 Code FBC2017/-rP[2014 Matnx-MS Scale = 1:49.0 PLATES GRIP MT20 244/190 Weight: 132 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1140/0-3-8,7=1140/0-3-8 Max Horz 2 135(1-C 10) Max Uplift 2 299([-C 12), 7 299([-C 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1909/608,3-4=-1661/573, 4-5 2130/792,5-6 1799/629, 6-7 1914/608 BOTCHORD 2-12=-425/1673, 10-12 216/1145, 9-1 0=-448/1641, 7-9=-445/1635 WEBS 3-12=-409/235, 4-12=-141/631, 4-10=-403/1080, 5-10 10851436, 6-10=-831522 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 6=45ft, L=27ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; M\1VFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 12-8-0, Exterior(2) 12-8-0 to 15-8-0, Interior(l) 18-4-0 to 28-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where 2 rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except @=Ib) 2=299,7=299. A Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 01111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(l) connectom. This design is based only upon paramelers shown, and is for an individual building component, not a truss system- Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to pre,rent collapse with possible personal injury and properly damage. For general guidance regarding the M- omm— fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSItTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Sufte 312, Alexandria, VA 22314, Tampa, FL 36610 Job T ss T ss Type Qty Park Sq Hms/ Sorrento-AorC 2078Ply T12944426 P2078AC-T B2 SPECIAL 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Jan 12 07:49:07 2018 Page I ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-a8R5QhJSYyPJubd)=gvRut41 1 J4U4xV9uN2vvzw9og 6-7-4 12-M 20-4-0 27-0-0 ?8-M 7-M 5-0-0 1-M, 6-74 -12 Scale = 1:49.0 4x4 13 11 10 9 3x5 1 X4 3x4 3x8 3.4 = 1.4 3x4 6-7-4 12-M LOADING (ps, SPACING- 2-0-0 CS1. TCLL 20.0 Plate Grip DOL 1.25 TC 0.80 TCDL 10.0 Lumber DOL 1.25 BC 0.73 BCLL 0.0 Rep Stress Incr YES WB 0.56 BCDL 10.0 Code FBC2017ITP12014 Matrix -MS DEFL. in (loc) I/defl L/d PLATES GRIP Vert(LL) -0.12 10-11 >999 240 MT20 244/190 Vert(CT) -0.29 10-11 >999 180 Horz(CT) 0.08 7 n/a n/a LLIMBER- BRACING- TOPCHORD 2x4 SP NO.2 *Except* TOPCHORD 4-5: 2x4 SP No. 1 BOTCHORD BOTCHORD 2x4 SP No.2 WEBS VVEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1140/0-3-8,7=1140/0-3-8 Max Horz 2 135([_C 10) Max Uplift 2 299([_C 12), 7=-299(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1 957/588, 3-4 1 398/494, 4-5=-1 413/470, 5-6=-2153/718, 6-7 2007/634 BOTCHORD 2-13=-412/1688, 11-13=-412/1688, 10-11 =-607/2187, 9-1 0=-489/1742, 7-9=-486/1739 WEBS 3-13=0/252, 3-11 =-613/243, 4-11 199/767, 5-11 1067/425, 5-1 O 590/256, 6-10 226/803 Weight 134 lb FT = 20% Structural wood sheathing directly appijed or 2-2-0 oc puriins. Rigid ceiling directly applied or 7-6-14 oc bracing. 1 Row at midpt 5-11 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf; h=25ft; 8=45ft; L=27ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.181 MVVFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 12-8-0, Extedor(2) 12-8-0 to 15-8-0, Interior(l) 20-4-0 to 28-0-0 zone;C-C for members and forces & MVVFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=299,7=299. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies A WARNING Verify design parameters and READ NOTES ON THIS AND INCLUDEDMITEK REFERENCE PAGE MII-7473 r— 1010312015 BEFORE USE. Design valid for use only with MiTek(ID connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verry the applicability of design parameters and properly incorporate this design into the overall s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the Kbuildingdesign. Bracing indicaled,is to prevent buckling of individual Iruss web and/or chord members only. Additional temporary and permanent bracing iro I fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSln`Pl1 Quality Criteria, DSB-89 and BCSI Building Component 69G4 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944427 P2078AC-T B3 SPECIAL I Job Reference (optional) Ivid-Flonda Lumber, bartow, L. ts. i ju s ,ep i z) zu i / MI I eK inaustries, Inc. rn jan I z u 1:4:uf zu i o rdye i ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-a8R5QhJSYyPJubdxxngvRutBmlJ3U2LV*guN2VVZw9og 7:8 L2 -0 22-" O Ig 8-M 1i 4X4 = 5 14 1.5 1 11 3x4 3X4 3X8 7x6 3X4 = 3X8 4x4 LOADING (ps" SPACING- 2-0-0 CS1. DEFL. in (loc) I/def! L/d TCILL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) 0.12 13 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.73 Vert(CT) 0.24 12-13 999 180 BCLL 0.0 Rep Stress Incr NO WB 0.66 Horz(CT) 0.08 9 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Scale = 1:49.0 PLATES GRIP MT20 244/190 Weight: 151 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 3-4-7 oc purlins. BOTCHORD 2x4 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied or 8-10-8 oc bracing. 9-13: 2x6 SP No.2 WE B S 2x4 SP No.3 REACTIONS. (lb/size) 2=1166/0-3-8,9=1521/0-3-8 Max Harz 2=-1 35(LC 6) Max Uplift 2 307(1_C 8), 9=-41 1 (LC 8) FORCES. (lb) -Max. Camp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2095/506,3-4 1963/507,4-5=-1406/409, 5-6=-1427/403, 6-7=-2165/547, 7-8=-30131745, 8-9 2674/659 BOTCHORD 2-15 379/1832, 14-15 273/1510, 13-14 373/1890, 12-13 689/3080, 11-12=-540/2425, 9-11 =-528/2377 WEBS 4-15=-77/393, 4-14=-456/174, 5-14=-250/950, 6-14=-845/271, 7-13=-1 243/332, 7-12=-6791196 8-12=-1 80/920, 8-11 =-I 23/491, 6-13=-82/504 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=27ft; eave=4ft; Cat. 11; Exp B; Encl., GCpj=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=307, 9=41 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 407 lb down and 133 lb up at 25-3-4 on bottom chord. The design/selection of such Connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-5=-60, 5-7=-60, 7-8=-60, 8-10=-60, 9-16 20 Concentrated Loads (lb) Vert: 21 407fl Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mli-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTeM connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bradng of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 Job Truss T ss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944428 P2078AC-T B4 SPECIAL 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Jan 12 07:49:08 2018 Page 1 ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-2K—udlK4JGXAV,AC7UVBS SPL9Re4Da3eNY6clLzw9of 8-8 2_:M0 0-0 21-2-12 57-0-0108TV11i 4-2 T8-_O 2. _0 5-2-12 5-94 Scale 1/4"=1' c? 5x5 4 4 = -- — 6 24 4x4l 725 1b 14 1.1 11 4x4 3x4 3x4 3X8 1.5X4 3x4l 3x4 = 8-10-8 1-M 5-5-8 5-2-12 5-94 Plate Offsets (X,Y)— [6:0-2-8,0-241 LOADING (psf) SPACING- 2-0-0 CS1. TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 TCDL 10.0 Lumber DOL 1.25 BC 0.81 BCLL 0.0 Rep Stress Incr YES WB 0.37 BCDL 10.0 Code FBC2017rrPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1140/0-3-8,9=1140/0-3-8 Max Horz 2 1 19(LC 10) Max Upljft 2 299([_C 12),9 299(1_C 12) DEFL. in (loc) I/defl L/d Vert(LL) -0.14 15-18 >999 240 Vert(CT) -0.29 15-18 >999 180 Horz(CT) 0.07 9 n/a n/a PLATES GRIP MT20 244/190 Weight: 146 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 3-10-8 oc purlins. BOTCHORD Rigid ceiling directly applied or 7-10-10 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1998/696, 34 1716/603, 4-5 1495/588, 5-6 1696/688' 6-7 1289/534' 7-8 1511/555, 8-9=-2000/637 BOTCHORD 2-15=-554/1760, 14-15=-393/1495, 12-14=-310/1294, 11-12=-494/1736, 9-11 494/1736 WEBS 3-15=-332/184, 4-15=-104/473, 5-14=-699/292, 6-14=-245/610, 7-112 120/408, 8-12=-525/218 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) \Afind: ASCE 7-10; Vuft=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=25ft; B=45ft; L=27ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-G-0 to 2-0-0, Interion(l) 2-0-0 to 8-1G-8, Exterior(2) 8-10-8 to 15-8-0, Interior(l) 15-8-0 to 28-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pond ing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=299,9=299. 14 6' Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies A WARNING - Verilydesign parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 re, 1010312015 BEFORE USE. Design valid for use only with MiTek(& conneclors. This design is based only upon parameters shown, and is fo an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall buildingdesign. Bracing indicated is to prevent buckling of individual muss web andlor chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing oftrusses and tnuss systems, see ANSIITPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, AJexandna, VA 22314. Tampa, FL 36610 Job T ss Truss Type Qty Ply Park Sq Hrns/ Sorrento-AorC 2078 T12944429 P2078AC-T B5 HIP 1 Job Reference Ioptional) mia-"Onaa Lumoer, bartow, - L. b.iju s z ep io zui i mi i eK inaustries, Inc. t-n jan iz u/:4 j:uv zuits t-age I ID:LwgEfgAbgYkKfRKdr2TZXPzS7xJ-WWYsrMLi4ZgO7vnK2CiNWJyWecL_8y3bocCs9Zozw9oe 94 13-" :2:0 2-2_ 2 27-0-0 -- 18 18ZL4114-2 112 4-9-44-94 112 4-" Scale = 1:47.2 4X4 3x4 4x4 4 20 5 21 6 12 10 4x4 US 3x4 3X8 4x4 LOADING (psf) TCLL 20.0 TCDL 10.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TPI2014 CS1. TC 0.41 BC 0.82 WB 0.23 Matrix -MS DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/defl L/d 0.14 10-18 >999 240 0.30 10-18 >999 180 0.07 8 n/a n/a PLATES GRIP MT20 244/190 Weight: 132 lb FT = 20% LUMBER- BRACING. TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 3-10-6 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 7-9-2 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1140/0-3-8,8=1140/0-3-8 Max Horz 2=-99(LC 10) Max Uplift 2 299([_C 12), 8=-299(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=19891718,34 11687/600, 4-5 1464/584,5-6=1464/584,6-7 1687/600, 7-8 19891718 BOTCHORD 2-12 570/1756,10-12 444/1606,8-10 578/1756 WEBS 3-12 349/228, 4-12=-126/494, 5-12=-296/134, 5-10=-2961134, 6-10=-126/494, 7-10=-349/228 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuft=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft, L=27ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18 ' MWFRS (directional) and C-C Exterior(2) -1 -0-0 to 2-0-0, Interion(l) 2-0-0 to 9-0-0, Exterior(2) 9-0-0 to 22-4-11, Interior(l) 22-4-11 to 28-0-0 zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except (it=lb) 2=299,8=299. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies M 11111132MEMMMMISIM11I WARNING - Verify design parameters and READ NO TES ON THIS AND INCL UDED MITEK REFERENCE PA GE 116111- 7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(& connectors. This design is based only upon parameters shown, and is for an inchAdual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MNo W, falbricnion, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 69G4 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944430 P2078AC-T B6 HIP 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FIL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Jan 12 07:49:10 2018 Page 1 ID:L,,gEfgAb9YkKfRKdr2TZXP;!S7.J-_j6E2iLKrtotl3MWcwDr-3VvVbfEKmhTaxrisbj6Ezw9od 1-M 7_o 11 _4_9 5-7-7 O 0 2-12 T7-0-1 -M 4' 1 3 12 3 8 2 3" _2. I11 -0 i 12 4,_g -2-13 14)-o 4x8 3x4 1 X4 11 4x8 4 21 522 23 24 6 25 26 7 14 1 . I I I 3x4 = 6x6 = 3X10 = 3X4 = 4x5 27-0-0 Scale = 1:47.2 4x5 — LOADING (psri SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) -0.21 12-13 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.80 Vert(CT) -0.43 12-13 >746 180 BCLL 10.0 Rep Stress Incr NO WB 0.44 Horz(CT) 0.13 9 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Weight: 140 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 2-2-12 oc purlins. BOTCHORD 2x4 SP No. 1 BOTCHORD Rigid ceiling directly applied or 5-10-10 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=202210-3-8, 9=2023/0-3-8 Max Horz 2=-79(LC 6) Max Uplift 2 607([_C 8), 9=-607(LC 8) FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3964/1173, 3-4=-3757/1129, 4-5 4188/1293, 5-6=-4211/1301, 6-7 4211/1301' 7-8=-375911129, 8-9=-3966/1172 BOTCHORD 2-14=-978/3504, 13-14=-894/3351, 12-13 11 161/4209, 11-12=-89413354, 9-11 =-978/3506 WEBS 3-14 265/98, 4-14=-71/604, 4-13=-339/1134, 5-13=-546/267, 6-12=-517/273, 7-12 345/1147, 7-11 =-71/611, 8-11 =-265/98 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf; h=25ft, B=45ft; L=27ft: eave=4ft Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom Chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except 0=1b) 2=607,9=607. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 189 lb down and 205 lb up at 7-0-0, 97 lb down and 106 lb up at 9-0-12, 97'lb down and 106 lb up at 11-0-12, 97 lb down and 106 lb up at 13-0-12, 97 lb down and 106 lb up at 13-11-4, 97 lb down and 106 lb up at 15-11-4, and 97 lb down and 106 lb up at 17-11-4, and 189 lb down and 205 lb up at 20-0-0 an top chord, and 327 lb down and 97 lb up at 7-0-0, 66 lb down at 9-0-12, 66 lb down at 11-0-12, 66 lb down at 13-0-12, 66 lb down at 13-11-4, 66 lb down at 15-114, and 66 lb down at 17-11-4, and 327 lb down and 97 lb up at 19-114 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 7-10 60, 15-18=-20 Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 re, 10/03/2015 BEFORE USE. Design valid for use only with MiTelk(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job T ss Trus Type oty Ply Park Sq HITS/ SorTento-AorC 2078 T12944430 P2078AC-T B6 HIP 1 Job Reference (optional) MIG-1-10n0a LUMDer, t5anow, t-L. zi.iju s oep 13 zul / MlIeK inaustnes, Inc. rn jan tz u/:,iv: iu zu io i-age z ID:LwgEfgAbgYkKfRKdr2TZXPzS7xJ-_j6E2iLKrtotl3MWcwDr-3VvVbfEKmhTaxrsbj6Ezw9od LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 4 142fl 7=-142(F) 13=-41(F) 14=327(F) 1 1=327(F) 21=97(F) 22=-97(F) 23=97(F) 24=97(F) 25=-97(F) 26=97(F) 27=-41(F) 28=-41(F) 29 41(1`) 30 41 (F) 31 =41 (F) A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE U11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTeM connectors. This design is based only upon parameters shown, and is for an indindual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall ANNE building design. Bracing indicated is to prevent buckling of indivdual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the WINTU111WON17 fabrication storage, delivery erecti n and bracing of trusses and truss systems, see ANSlrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety lnf mnation available fromoTruss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944431 P2078AC-T C1 HIP 1 Job Reference (ontiona ) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Jan 12 07:49:11 2018 Page I ID:LwgEfgAb9YkKfRKdF2TZXPzS7xJ-SvgcG2MzcBwkNDxiAdkrbkltgejPQwc43V4LGegzwgoc 5-9-4 0 14-t-0 1M-12 25-2-8 5-9-4 _25-2 3 5-2-12 5-7-12 Scale = 1:43.3 4x8 4x4 cs 21 22 3x4 = 1.4 11 3x4 = 3x4 =3x8 = lx4 11 3x4 = 5-94 LOADING (ps, SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCOL 10.0 Code FBC2017rrPI2014 11-0-0 CS1. DEFL. in (loc) I/defi L/d TC 0.34 Vert(LL) 0.07 11 999 240 BC 0.51 Vert(CT) 0.14 11-12 999 180 WI3 0.39 Horz(CT) 0.06 7 n/a n/a Matnx-MS PLATES GRIP MT20 244/190 Weight: 130 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 4-1-0 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 8-3-10 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 7=1007/Mechanir-al, 2=1070/0-3-8 Max Horz 2= 1 14(LC 11) Max Uplift 7 239(1_C 12), 2=283(LC 12) FORCES. (b) -Max. Comp./Max. Ten. -All forces 250 (b) or less except when shown. TOPCHORD 2-3=-1852/612,3-4=-1343/507,4-5 1138/498,5-6 1343/507,6-7 1826/603 BOTCHORD 2-12 5011/11603,111-112=-5011/11603, 9-11 =-292/1137, 8-9=-478/1576, 7-8 478/11576 WEBS 3-11 =-543/240, 4-11 =-91/350, 5-9 11 09/346, 6-9=-516/232 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd'--108mph; TCDL=4.2psf ' BCDL=3.Opsf; lt=25ft B=45ft; L=25ft; eave=4ft; Cat. 11; Exp B Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 11-0-0, Exterior(2) 11-0-0 to 14-4-0, I terior(l) 18-6-15 to 25-2-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=11.60 plate grip DOL=11.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom Chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except 0=11b) 7=239,2=283. 6 Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE U11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(ID connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the M NOW fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Trus Type Qty Ply Park Sq Hms/ Soryento-AorC 2078 T12944432 P2078AC-T C2 HIP 1 Job Reference (optional) mia-t-ioncia Lumber, bartow, t-L. j.i,,u s z3ep to zu I i mi I eK industries, Inc. rn jan iz ul:q-j: iz zu jo rage i ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-w5E—TONbNU2b—MWvjLG48xavd2Ov9RNEIA4pA6zw9ob 9-0-0 16-4-0 T -12 25-4-01-291 4-2-12 7-" 4121 4-9-4 41 cs 4x6 4 19 20 21 22 4x8 5 11 9 4x4 3x8 U4 3x4 4x4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Lld TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) 0.15 9-17 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.75 Vert(CT) 0.33 9-17 913 180 BCLL 0.0 Rep Stress Incr YES WB 0.16 Horz(CT) 0.06 7 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1073/0-3-8,7=1073/0-3-8 Max Horz 2 97([-C 10) Max Uplift 2 283(!-C 12), 7=-283(LC 12) Scale = 1 44.5 PLATES GRIP MT20 244/190 Weight: 121 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or 8-1-3 oc bracing. WEBS 1 Row at midpt 5-11 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1 832/667, 3-4=-1 545/560, 4-5 1 340/551, 5-6=-1 545/560, 6-7 1 832/667 BOTCHORD 2-11 =-523/1615, 9-11 =-347/1340, 7-9 531/1615 WEBS 3-11 =-321/209, 4-11 =-45/402, 5-9 49/402, 6-9=-3211209 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. 11; Exp B, Encl., GCpi=0.18; MWFRS (directional) and C-C Exlerior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 9-0-0, Exteror(2) 9-0-0 to 20-8-11, Interior(l) 2"-11 to 26-4-0 zone,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-G-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at Joint(s) except (=lb) 2=283,7=283. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Veritydesign parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 r— 1010312015 BEFORE USE. Design valid for use only with MiTelk(ll) connectors. This design is based only upon parameters shown, and is for an indivdual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 10- NMI fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and EICSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Instilule, 218 N. Lee Streel, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Trus Type QtY Ply Park Sq Hms/ Sorrento-AorC 2078 T12944433 P2078AC-T C3 HIP I Job Reference (ontional) Mid-Floricla Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fn Jan 12 07:49:13 2018 Page I ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-0ioNhkODBoAScW55H2nJh979mSiSurmNXqqNjZzw9oa 1-M 3-9- 7 14 8-4-0 t 2 -0 126-4-0 3_'-31 391521-1!155 12-1'2 3 !gI 1 Scale = 1:44.5 4x5 = 4x8 = 3X4 = 1 x4 11 4 21 5 22 23 24 6 25 4x8 = 14 1J 1-1 11 3x4 = 5X5 = 3X8 = 3x4 = 7-0-0 15 11-4 25-4-0 7-0-0 i 1309; 15 7-M 4x5 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) -0.18 12-13 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.99 Verl(CT) -0.37 12-13 >832 180 BCLL 0.0 Rep Stress Incr NO A1B 0.34 Horz(CT) 0.13 9 n1a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weighti 133 Ib FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1887/0-3-8, 9=1888/0-3-8 Max Horz 2=-77(LC 6) Max Uplift 2 567([_C 8), 9=-567(LC 8) BRACING - TOP CHORD Structural wood sheathing directly applied or 2-7-4 oc purlins. BOTCHORD Rigid ceiling directly applied or 5-11-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3669/1086, 3-4=-3456/1040, 4-5=-3692/1146, 5-6 3714/1152, 6-7=-3714/1152, 7-8=-3459/1040, 8-9=-3671/1086 BOTCHORD 2-14 900/3243, 13-14 814/3081, 12-13=-1012/3710,11-12=-814/3084, 9-1 1=-90013244 WEBS 3-14 268/101, 4-14=-731598, 4-13 2731892, 5-13 470/228, 6-12=-439/237, 7-12 277/903, 7-1 1=-73/604, 8-1 1 268/100 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10, Vuft=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=25ft, B=45ft, L=25ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pon ing. 4) This truss has been designed for a 10.0 psf bottom Chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=567,9=567. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 189 lb down and 204 lb up at 7-0-0, 97 Ib down and 106 Ib up at 9-0-12, 97 Ib down and 106 lb up at 1 1-G-1 2, 97 lb down and 106 lb up at 12-8-0, 97 lb down and 106 lb up at 14-3-4, and 97 lb down and 106 lb up at 16-3-4, and 189 lb down and 204 lb up at 18-4-0 on top chord, and 327 lb down and 97 Ib up at 7-0-0, 66 lb down at 9-0-12, 66 lb down at 11-0-12, 66 lb down at 12-8-0, 66 lb down at 14-34, and 66 lb down at 16-3-4, and 327 lb down and 97 lb up at 18-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plf) vent: 1-4 60, 4-7=-60, 7-10=-60, 15-18=-20 Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE L111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekS connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall ibuilding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracingsalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalinjuryandproperlydamage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type aty Ply Park Sq Hms/ SorTento-AorC 2078 T12944433 P2078AC-T C3 HIP 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 8.130s bep 15 2017 Miiekindustnes, Inc. I-nJan1Z01A9:13ZU1b Hagez ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-0loNhkOD8oAScW55H2nJh979mSiSurTnNXqqNjZzw9oa LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 4 142(1`) 7=-142(F) 14=-327(F) 5=97(F) 6=-97(F) 12=41 (F) 11 =327(F) 21 =-97(F) 23 97fl 25 97fl 26=4 1 (F) 27=41 (F) 28 41 (F) 29=41 (F) WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Mi7ekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing i s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the - - - fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Truss Type city Ply Park Sq Hms/ Sorrento -AorC 2078rusKs T12944434 ci JAC 4 1 Job Reference (oDt ona Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Jan 12 07:49:13 2018 Page 1 ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-0ioNhkOD8oAScW55H2nJh97GqSXTuw7NXqqNjZz\A/9oa 1-0-0 1-0-0 Scale = 1: 10.7 01-0 LOADING (psf) SPACING- 2-G-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.14 Vert(LL) 0.00 5 >999 240 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.03 Verl(CT) 0.00 5 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017fTPI2014 Matrix -MR Weight: 6 lb FT = 20% LUMBER- IBRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 1-0-0 oc purlins, BOTCHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=149/0-4-0,3=-12/Mechanir-al,4 l/Me&anicaI Max Horz 5=43(LC 12) Max Uplift 5=-54(LC 12),3=-12(LC 1), 4=-10(LC 12) Max Grav 5=1 49(LC 1), 3=3(LC 8), 4=1 3(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph: TCDL=4.2psf; BCDL=3.Opsf h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2) zone,C-C for members nd forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies I A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev 1010312015 BEFORE USE. Design valid for use only with MiTeM connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Infonmation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944435 P2078AC-T Cil JACK 18 Job Reference (optional) Mia-t-lonaa Lumber, Bartow, t-L. u.iju s z ep to zu-i I mi ieK inaustnes, Inc. t-n jan iz uv,%v:i4 zui " "age i ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-tUMiu4Orv6lJEggHdIYDMfSirt—dNNX.UZwF?zw9oZ 1-M 1-0-0 1-0-0 LOADING (psf) SPACING- 2-0-0 CS1. TCLL 20.0 Plate Grip DOL 1.25 TC 0.07 TCDL 10.0 Lumber DOL 1.25 BC 0.01 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TP12014 Matnx-MP LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 REACTIONS. lb/size) 3=10/Mechanical,2=130/0-3-8,4=-O/Mer-hanicaI Max Horz 2=42(LC 12) Max Uplift 3=-3(LC 9), 2 73(!-C 12) Max Grav 3=1 1 (LC 17), 2=1 30(LC 1), 4=1 2(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown Scale = 1:7.0 2X4 = DEFL. in (loc) I/defl L/d PLATES GRIP Verl(LL) 0.00 5 >999 240 MT20 244/190 Vert(CT) 0.00 5 >999 180 Horz(CT) 0.00 2 n/a n/a Weight: 5 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 1-0-0 cc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 cc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft. L=24ft; eave=4ft, Cat. 11; Exp B; Encl., GCpi=0.181 MWFRS (directional) and C-C Exierior(2) zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE FAII-7473 r— 1010312015 BEFORE USE. Design valid for use only with MiTelkS connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSirrPil Quality Criteria, DSB-89 and SCSI Building Component Safety Infonnation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FIL 36610 Job Trus Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 207 8 T12944436 P2078AC-T CJ13 JACK 14 1 Job R efere Mid -Florida Lumber, Bartow, FL. 2x4 = 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Jan 12 07:49:14 2018 Page 1 ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-tUMiu4Orv6lJEggHrilYDMfSLrszdNNXmUZwF?zw9oZ 3-0-0 3-0-0 3-0-0 LOADING (ps, SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) 0.00 4-7 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.08 Vert(CT) 0.01 4-7 999 180 BCLL 0.0 Rep Stress Incr YES VV13 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=71 /Mechanical, 2=1 88/0-3-8, 4=36/Mechanical Max Horz 2=74(LC 12) Max Uplift 3 34(1_C 12), 2=-66(LC 12) Max Grav 3=71(LC 1), 2=188(LC 1), 4=52(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale: V=1' PLATES GRIP MT20 2"/190 Weight: 11 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph: TCDL=4.2psf; BCDL=3.Opsf; h=25ft, B=45ft, L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-G-0 to 2-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) 3, 2. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Venify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 — 10/03/2015 BEFORE USE. Design valid for use only with Miirekli) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall bu ild ing design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only, Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 69G4 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento-Aorc 2078 T12944437 P2078AC-T CJ3T SPECIAL 2 Job Reference oPtional) Mia-l-lonaa Lumber, t3artow, F L. 1 1 j.i,5u s ,ep io zu I i MI I eK inausines, Inc. rri jan iz ui:4ti: to zujo rdq i ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-Lgw75QPTgPQkqETPTpnmaCdjFBGMqdg_8JTnRzw9oY 2-5-0 :0ii 1 Izm ! I2-5-0 F2:1 Scale: 1"=1' 2x4 = 4 99 2-5-0 b-2-8 6--48 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/defi Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.11 Vert(LL) 0.01 7 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.14 Vert(CT) 0.01 7 999 180 13CLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.01 5 n/a n1a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MR Weight: 13 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 *Except* 3-7: 2x4 SP No.3 REACTIONS. (lb/size) 2=189/0-8-0,5=116/Mechanical Max Horz 2=81 (LC 12) Max Uplift 2=-64(LC 12),5=-46(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. BRACING- TOPCHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11; Exp 8; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 3-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) 2, 5. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies M WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(g) connectors. This design is based only upon parameters shown, and is for an indivdual building component, not a truss system. Before use, the building designer must venfy the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indinodual truss web and/or chord members only. Additional temporary and permanent bracing s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB.89 and BCSI Building Component 69G4 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, AJexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply Park Sq Hms/ Sorrento-AorC 2078 T12944438 P2078AC-T CJ4 JACK 1 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. 3x4 = 4-7-8 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Jan 12 07:49:16 2018 Page I ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-ptTVJmQ5QjYlT—PgyAKOink[YfWt5HtqDo2lJuzw9oX Scale = 1:17.1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.30 Vert(LL) 0.03 3-6 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.25 Vert(CT) -0.05 3-6 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.01 1 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MP Weight: 15 Ib FT = 20% LUMBER- BRACING- TQPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 4-7-8 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=183/0-3-8,2=123/Mechanical, 3=59/Mechanical Max Horz 1 =76(LC 12) Max Uplift 1 =-21 (LC 12), 2=-65(LC 12), 3=1 (LC 12) Max Grav 1=183(LC 1), 2=123(LC 1), 3=86(LC 3) FORCES. (lb) - Max. Co mp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES. 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf BCDL=3.Opsf h=25ft; B=45ft; L=24ft eave=4ft; Cat. 11, Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to -0-0, lnterior() 3-0-0 to 4-6-12 zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 3. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mli-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use,,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Typ Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944439 P2078AC-T CJ15 JACK 13 Job Reference (optional) 10 ti.iju s bep io zui i mi ieK industries, inc. t-n jan I Z UfAbl: I b ZU I b Fage i ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-ptTVJmQ5QjY1 T—PgyAK01 nkkDfvy5Htq Do21 Juzw9oX 5-0-0 1-0-0 5-0-0 2x4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) 0.04 4-7 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.26 Vert(CT) 0.06 4-7 988 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code F8C2017/TPI2014 Matrix -MP LUMBER- BRACING. TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP No.2 BOTCHORD REACTIONS. (lb/size) 3=127/Mechanir-al,2=264/0-3-8,4=64/MechanicaI Max Horz 2=108(LC 12) Max Uplift 3=-64(LC 12), 2=-73(LC 12) Max Grav 3=127(LC 1), 2=264(LC 1), 4=91(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown Scale = 1: 17.0 PLATES GRIP MT20 244/190 Weight: 18 lb FT = 20% Structural wood sheathing directly applied or 5-0-0 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES. 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft, L=24ft; eave=4ft; Cat. 11, Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterion(2) -1-0-0 to 2-0-0, Interion(l) 2-0-0 to 4-11-4 zone'C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valdforuse onlywith MiTek@ connectors, This design is based only upon parameters shown, and isforan indiodual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indidual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 10 MUM, fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSlrrPl1 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento -AorC 2078 T12944440 P2078AC-T CJ5T SPECIAL 2 1 Job Reference (ootionah Mia-Honcla Lumber, Bartow, FL. 14I 1 8.130 S bep 15 2017 Mi I ek Industries, Inc. Fn Jan 12 07:49:17 2018 Page 1 ID:LwgEfgAbgYkKfRKdr2TZXPzS7xJ-H3ltW5RjBIgu58OsWurFOHtU3qsq7zSSoasKzw9oW 1-0-0 2-7-8 2-4-8 2x4 = Scale = 1: 17.0 2-7-8 5-M 2-7-8 2-4-8 Plate Offsets (X,Y)— 2:Edqe,0-0-41.[3:0-3-8,0-2-0l LOADING (psf]i SPACING- 2-0-0 CS1. DEFL. in floc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.48 Vert(LL) 0.07 6 >802 240 MT20 244/190 TCDL 10.01 Lumber DOL 1.25 BC 0.32 Vert(CT) -0.10 6 >597 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.05 5 n/a n/a BCDL , 10.0 Code FBC2017frPI2014 Matrix -MR Weight: 19 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOTCHORD 2x4 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. 3-7: 2x4 SP No.3 REACTIONS. (lb/size) 4=1 14/Mechanical, 2=267/0-8-0, 5=81/Mechanical Max Horz 2=108(LC 12) Max Uplift 4=-49(LC 12), 2=-72(LC 12), 5=-13(LC 12) Max Grav 4=1 14(LC 1), 2=267(LC 1), 5=88(LC 3) FORCES, (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11 Exp B, Encl., GCpi=0.18 MWFRS (directional) and C-C Exterior(2) -1-G-0 to 2-0-0, Interior(l) 2-0-0 to 4-11-4 zone'C-C for embers and forces & M\FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2, 5. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOrES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 r— 1010312015 BEFORE USE. Design valid for use only with MiTek(R) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary andpermanent bracing Visalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regarding the E fabncation, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Adexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Sq Hms/ Sorrento-AorC 2078 T12944441 P2078AC-T D1 SPECIAL 1 3 park ah IV110-1-101-10a LUMDeF, tianow,rL. —P ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-lFbGkRSMyKo]iHz24bMUOCqwkT1 HZy76g6X80mzv4goV 5-3-0 9-11-8 1 6-3 18-'-' -3' 5-3-0 4-8-8 T1 - 1' 21-11:3 202-8 Scale = 1 38.0 c? 3X4 8XIO 5X5 8x1 0 MT20HS 4x4 2x4 5X14 = 5X8 MT20HS I 3-Ci 110- 5- 1 13 IE -53 1 o-l B I _ 0 4-M 19 2 -11:3 _0_1 1 2-113 2-2 Plate Offsets (X,Y— 5:0-3-12,0-3-41,[11:Edge,0-3-81,[15:0-5-0,Edgel,fl7:0-5-0,Ed-geI LOADING (psq SPACING- 1-4-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.00 TC 0.96 Vert(LL) 0.42 15-16 >582 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.88 Vert(CT) -0.72 15-16 >337 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incir NO WB 0.91 Hor7(CT) 0.07 11 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 368 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-6-7 oc purlins, 5-10: 2x4 SP No. 1 D except end verticals. BOTCHORD 2x6 SP DSS BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.2 *Except* 10-11,3-17,3-5,6-15,7-14,8-13,9-12: 2x4 SP No.3 REACTIONS. (lb/size) 11 =5533/0-3-8, 2=2397/0-8-0 Max Horz 2=1543(LC8) Max Uplift 1 1=-1954(LC 5), 2 51 O(LC 5) Max Grav 11 =6575(LC 13), 2=2612(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-5924/1250, 3-4=-494/239, 5-16=-780/254, 5-6=-25866/8266, 6-7=-25874/8269, 7-8=-24846/7713, 8-9 1 125813380, 9-10=-1 1258/3380, 10-11 =-5824/1738 BOTCHORD 2-17 256016062, 16-17=-7215/22186, 15-16=-7946/23843, 14-15=-7713124846, 13-14=-6193/20341, 12-13=-6193/20341, 11-12=-2351791 WEBS 3-17=-1258/4390, 3-5=-5660/1672, 5-17 16475/4756, 6-15=-1496/486, 7-14=-2116/710, 8-13=-99/390, 9-112 1474/416, 5-15=-353/2257, 7-15 615/1132,10-12=-3468/11541, 8-12 1 0011/3101, 8-14=-1675/4966 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - I row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 8=45ft; L=24ft, eave=4ft, Cat. 11, Exp B ' Encl., GCpi=O.l 8; M\AIFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Printed copies of this document arewillfitbetweenthebottomchordandanyothermembers. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) not considered signed and sealed and 11=1954,2=510. the signature must be verified on 10) Girder carries tie-in span(s): 27-0-0 from 10-0-0 to 20-3-8 any electronic copies11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) . The design /selection of such connection device(s) is the responsibility of others. LONf#7"WJVdWgW0 parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 r— 1010312015 BEFORE USE. Design valid for use only with MiTelkO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must venfy the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing i s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the I fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944441 P2078AC-T D1 SPECIAL 1 3 Job Reference (optional) Mid -Florida Lumber, Bartow, FL. b.lju s Zziep I b zu I I Mi I eK industries, Inc. i--n jan 12 U/:4 1: I b ZUI?J i--age z ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-lFbGkRSMyKoliHz24bMUOCqwkT1 HZy76g6X80mzwgoV LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (pIf) Vert: 1-4 40, 5-1 0=-673, 2-11 =- 13 Concentrated Loads (lb) Vert: 5=-275 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(g) connectors. This design is based only upon parameters shown, and is for an individual building component, not a ss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overallt" 10— building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing i ' always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabncation, storage, delivery, erection and bracing of trusses and truss systems, see " ANSlITPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq HITS/ Sorrento-Aor-C 2078 T12944442 P2078AC-T D2 HIP I Job Reference (ootionah mia-rionaa Lumoer, banow, t-L d,13us6ep lb2ul/ milek industries, Inc. FnJanlZU/:49:182018 Pagel ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-lFbGkRSMyKo]iHz24bMUOCq2UT4HZ8W6g6X80mzw9oV 4-9-4 11-8-0 15-10-12 20-3-81-M 9-0 1 4-94 2-8-0 4-2-12 4-4-12 Scale = 1:35.1 3 4x4 4x8 4 4X4 3X8 = 4X4 3x4 4X4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.46 Vert(LL) 0.14 10-16 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.69 Vert(CT) 0.31 10-16 788 180 BCLL 0.0 Rep Stress Incr YES VVB 0.18 Horz(CT) 0.03 7 n/a n/a BCDL 10.0 Code FBC2017/-rP[2014 Matrix -MS PLATES GRIP MT20 2441190 Weight: 100 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 4-7-6 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 8-10-6 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 7=810/0-3-8, 2=873/0-8-0 Max Horz 2=94(LC 11) Max Uplift 7 192(!-C 12), 2 237(1-C 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1404/529, 3-4=-1092/411, 4-5=-922/412, 5-6=-1070/407, 6-7=-1353/501 BOTCHORD 2-10 441/1236, 8-10=-220/906, 7-8=-399/1162 WEBS 3-1 O 365/229, 4-1 0=-80/308, 5-8=-52/264, 6-8=-3051208 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft, B=45ft; L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18, MWFRS (directional) and C-C Exterjor(2) -1-0-0 to 2-0-0, Interion(l) 2-0-0 to 9-0-0, Exterior(2) 9-0-0 to 11-8-0, Interior(l) 16-0-11 to 20-3-8 zone,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 7=192,2=237. 7 R - Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must venly the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indiOdual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944443 P2078AC-T D3 HIP 1 all Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 Mi I elk Industries, Inc. t-n jan 12 U/:49:19 2uld Fage i ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-DS9exnS jewcKRYFeJujwQM7bsPZIZfGvmHhwCzw9oU 3- -4 7-0-0 10_40 13-8-0 1E-10-12 20-3-8 i 3_2_121zz3-2-12 3 3-4-0 3-4-12 Scale = 1:35.6 4x4 3x4 4x4 4 18 19 5 20 6 4x4 = 3X8 = 414 = 3x8 = 4x5 = LOADING (psf) TCLL 20.0 TCDL 10.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr N 0 Code FBC20171TPI2014 CS1. TC 0.89 BC 0.75 WB 0.32 Matrix -MS DEFL. in Vert(LL) -0.12 Vert(CT) -0.28 Horz(CT) 0.07 loc) I/defl L/d 9-11 >999 240 9-11 >863 180 8 n1a n/a PLATES GRIP MT20 244/190 Weight: 100 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 2-6-7 oc purlins. BOTCHORD 2x4 SP No.1 BOTCHORD Rigid ceiling directly applied or 7-3-6 oc bracing. WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 REACTIONS. (lb/size) 8=149910-3-8,2=1537/0-8-0 Max Horz 2=75(LC 7) Max Uplift 8=431 (LC 8), 2=-467(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2924/867, 3-4=-2718/815, 4-5=-2422/758, 5-6=-2362/743, 6-7=-2630/795, 7-8=-2750/821 BOTCHORD 2-11 =-738/2576, 9-11 =-745/2591, 8-9=-686/2373 WEBS 3-11 =-267/111, 4-11 =-1 70/833, 5-11 =-301/162, 5-9=-387/188, 6-9=-1 54/771 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf, h=25ft; B=45ft, L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional), Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 8=431,2=467. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 189-lb down and 204 lb up at 7-0-0, 97 lb down and 106 Ito up at 9-0-12, 97 lb down and 106 lb up at 10-4-0, and 97 lb down and 106 lb up at 11-7-4, and 189 lb down and 204 lb up at 13-8-0 on top chord, and 327 lb down and 97 lb up at 7-0-0, 66 lb down at 9-0-12, 66 lb down at 10-4-0, and 66 lb down at 11-7-4, and 327 lb down and 97 lb up at 13-7-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Printed copies of this document are 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) not considered signed and sealed and Vert: 1-4=-60, 4-6=-60, 6-8=-60, 12-15=-20 the signature must be verified on Concentrated Loads (lb) any electronic copies Vert: 4=-142(F) 6=-142(F) 11=-327(F) 5=-97(F) 9=-327(F) 19=-97(F) 20=-97(F) 21=-41(F) 22 41fl 23=-41(F) WARNING -Verify designpammeters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with M[Tek(b conneclors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andior chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Infonnation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job TE1 russ russ Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 FC0110N T12944444 P2078AC-T Job Refe iviia-rionaa Lumuer, DaROW, r L. b.i 6u s z,ep io zui ( mi i eK inaustnes, Inc. I-n jan iz uf: Zzu zui?j -age i ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-hejO97TcUy2Tyb7RBOPyTdvQUGtJ1 3mP8P0ESfzw9oT 1-0-0 5-M 1 0-M 11-0-0 1:61 5-M 5-0-0 1-0-0 Scale = 1:24.8 4X4 = 3 11 OX4 11 Ll 5-M i 10-M 4-M 5-M Plate Offsets (X,Y)— 2:0-2-15.0-2-01, [4:0-2-15,0-2-01 LOADING (psf) SPACING. 2-0-0 CS1. DEFL. in loc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) -0.01 7-8 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.21 Vert(CT) -0.03 7-8 >999 180 3CLL 0.0 Rep Stress Incr YES W13 0.07 Horz(CT) 0.00 6 n/a n/a BCDL 10.0 Code FBC2017/TP120114 Matrix -MS Weight: 55 lb FT = 20% LUMBER- BRACING. TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=457/0-4-0, 6=457/0-8-0 Max Horz 8=57(LC 11) Max Uplift 8=-157(LC 12),6=-157(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TORCHORD 2-3=420/248 34 420/248, 4-6=-413/330, 2-8=-413/330 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11, Exp B; Part. Encl., GCpi=0.55; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 5-0-0, Exterior(2) 5-0-0 to 8-0-0 zone ' cantilever left exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 8=1 57, 6=1 57. Printed copies -of this document are not considered signed and sealed and the signature must be verified on any electronic copies A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTeMD connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling ofindivdual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIFrPll Quality Criteria, DS"9 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Nexandria, VA 22314. Tampa, FL 36610 Job T ss Truss Type Qty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944445 P2078AC-T E2 HIP 1 Job Referen Mid-Flonda Lumber, Bartow, FL. 1 —" lm—' 1 3-0-0 4x8 = 8.13U s bep lb zol I Mi I eK inaustnes, Inc. t-n jan iz 07:49:2i 20io Page i ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-9qHOMTUEFFAJZ]idlkwB?rSd4gE 1 mViZN3mo?5zw9oS 4-0-0 4x4 12 13 4 3-0-0 1 1-M 3X4 11 3x5 xo — 7 1.5x4 11 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 3-0-0 7-0-0 10-0-0 U-5 2-8-0 4-0-0 3-0-0 Scale = 1 i22.6 LOADING (psf]l SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.25 Vert(LL) 0.01 8-9 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 Bc 0.18 Vert(CT) 0.02 8-9 999 180 BCLL 0.0 Rep Stress Incr NO WB 0.15 Horz(CT) 0.00 7 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MS Weight 56 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 10=497/0-4-0,7=497/0-8-0 Max Horz 1 0=-39(LC 6) Max Uplift 1 0=-250(LC 8), 7 250([_C 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-501/278, 3-4=-411/267, 4-5=-5011277, 5-7=-469/256, 2-1 0=-4691257 BOTCHORD 8-9=-209/41 1 WEBS 5-8=-212/406, 2-9=-213/406 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft, B=45ft; L=24ft, eave=4ft; Cat. 11 Exp B; Part. Encl., GCpi=0.55; MWFRS (directional); cantilever left exposed I Lumber DOL=1.60 plate grip DOL=11.60 3) rovide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 10=250,7=250. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 65 lb down and 182 lb up at 3-0-0, and 9 Ito down and 76 Ito up at 5-0-0, and 65 lb down and 182 lb up at 7-0-0 on top chord, and 26 lb down and 30 Ito up at 3-0-0, and 12 Ito down and 13 lb up at 5-0-0, and 26 lb down and 30 lb up at 6-11-4 an bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 4-5 60, 5-6=-60, 7-1 0=-20 Concentrated Loads (lb) Vert: 3 18fl 4=_ 18(F) 9=-14(F) 8=-14(F) 12=-9fl 14=-8(F) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies M WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 r— 1010312015 BEFORE USE Design valid for use only with MiTekS connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indivridual truss web and/or chord members only. Addilional temporary and permanent bracing I aNoW, is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the - fabrication, storage, delivery, erect ion a nd braci ng of trusses an d truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944446 P2078AC-T F1 ROOFTRUSS 4 Job Reference (optional) H 1 1-3-0 5X6 1x3 = 1X3 = 1 5 4 4X6 2 R&:12d 3X4 = 3X8 FP 3x3 1 X3 11 3x3 3 4 5 6 7 0''Z 5 07P 10 Z U I i M I I eK I no ustries, I nc. r n ja n I z u /: qtl: zz zu I o Vage I ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-eOrmZpVsOZIABvHqJRROY2—b44Rr\4hibjVLXXzw9oR Scale = 1:33.8 3x3 3x4 4x6 5x6 8 9 10 11 9 2X4 5X8 4X6 3x4 3X3 = 1 x3 3x3 3X4 4X6 3x8 FP = 3x3 5x6 Plate Offsets (X,Y)— ll:Edge,0-1-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/def! L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 1.00 Vert(LL) -0.39 18 >613 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.71 Vert(CT) -0.54 18 >447 240 BCLL 0.0 Rep Stress Incr NO WB 1.00 Horz(CT) 0.09 12 n/a n/a BCDL 5.0 Code FBC2017/TPI2014 Matrix-S Weight: 106 lb FT = 20%F, 1 I%E LUMBER- BRACING- TOPCHORD 2x4 SP No.2D(flat) TOPCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORD 2x4 SP DSS(flat) *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 12-14: 2x4 SP No.2(flat) WEBS 2x4 SID No.3(flat) REACTIONS. (lb/size) 23=1566/0-8-0, 12=1210/0-3-8 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-23 1532/0, 11-12=-1203/0, 1-2=-155D/0, 2-3=-3838/0, 3-5=-5122/0, 5-6 54915/0' 6-7 5496/0, 7-8=-5262/0, 8-9=-4501/0, 9-10=-317310, 10-11 =-1 248/0 BOTCHORD 21-22=012841, 20-21 =0/4607, 19-20=0/5425, 18-19=0/5496, 17-18=0/5496, 16-17=0/5017, 15-16=0/3959, 13-15=0/2362 WEBS 11-13=0/1662, 1-22=0/2107, 10-13=-1549/0, 2-22=-1796/0, 1G-15=0/1129, 2-21=0/1386, 9-15 1093/0, 3-21=-1070/0, 9-16=0/754, 3-20=0/717, 8-16=-718/0, 5-20=479/0, 8-17 27/521, 5-19=-313/500, 7-17 602/156 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. 4) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 23-26=-85(F=-75), 12-26 1 0, 1-11 =-100 Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTeM connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andior chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing oftmsses and truss systems, see , ANSIrl"I'll Quality Criteria, DSB-89 and BCSI Building Cornponent 6904 Parke East Blvd. Safety Inforniation available from Truss Plate Institute, 218 N. Lee Street, suite 312,AJe ndria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944447 P2078AC-T F2 ROOFTRUSS 10 Job Reference (opti ivino-t-ionaa Lumcer, banow, t-L. i 1-3-0 1 4X6 = 3x3 2 0. 1,31.1 5 Oep 10 ZU I/ IVII I eK I HU1.15111eb, 111G. 1-11 Jdl I I Z UIA.44 ZU 10 rdyu I ID:qR7GTqtGeHxJkx7yRAMor5yENix-eOrmZpVsOZIABvHqJRRQY2—hE4QQVsribjVLXXzw9oR 1-5-8 O-P_ Scale = 1 26.5 4X4 = 3x3 i X3 30 3x3 3x3 1x3 3 4 5 6 7 8 18 911T 3X3 4x5 3x3 3x3 1X3 11 3x3 3X3 4x4 3X3 2-M 5-3-0 1 10-8-8 1 13-2-8 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (10 c) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.61 Vert(LL) -0.17 12-13 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.81 Vert(CT) -0.23 12-13 >816 240 BCLL 0.0 Rep Stress Incr YES WB, 0.55 Horz(CT) 0.04 9 n/a n/a BCDL 5.0 Code FBC20171TPI2014 Matrix-S Weight: 84 lb FT = 20%F, 11 %E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 cc purlins, BOTCHORD 2x4 SP No.1(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS. (lb/size) 17=864/Mechanir-al, 9=858/0-3-8 FORCES. (lb) -Max. Comp,/Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-1 7 860/0, 8-9=-853/0, 1-2=-860/0, 2-3=-2054/0, 3-4=-2774/0, 4-5=-277410, 5-6 2671/0, 6-7=-2069/0, 7-8 856/0 BOTCHORD 15-16=0/1 614, 14-15=0/2489, 13-14=0/2774, 12-13=0/2774, 11-12=0/2509, 10-11 =0/1 607 WEBS 8-1 0=0/1 104, 1-16=0/1 145, 7-1 0=-1 044/0, 2-16=-1 049/0, 7-11 =0/642, 2-15=0/612, 6-11 612/0, 3-15=-605/0, 6-12=0/333, 3-14=0/581, 5-12=-3681108 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 cc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(S) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indmilual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the am Blvdarkfabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrl"I'll Quality Criteria, DSB-89 and BCSI Building Component 6904 P 7 e East Blvd. Safety Information available fromTruss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FIL 36610 Truss Truss Type City Ply Park Sq Hms/ Sorrento-AorC 2078 T12944448 F2A GABLE 1 Job Reference ontional) rvio-t- ionaa LumDer, t3arlOW, l- L. ts. iiu s z:,ep I o zu I i mi I eK inausines, Inc. rn jan i z u zu i " "ge I ID:qR7GTqtGeHxJkx7yRAMor5yENix-6DOgn9VUntQlp3sOt8yf5GX_HUx4ER8rqNFvLZW9OQ 0-0j8 Scale 1:26.5 3X3 11 1 2 3 4 5 6 7 8 9 10 11 12 13 LJ LJ LJ LJ L] 27 9 26 25 24 23 22 21 20 19 18 17 16 15 14 3X3 11 3x3 7-4-4 B-1-0 5-4 &7-8 6-810 :,3-8 _t78 i 1 L; I I i 1F33-8 14:t7811L421tQ041110 I 04 J_ 8 1 G-8-4 0.1-4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.08 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(CT) 0.00 14 n/a n/a BCDL 5.0 Code FBC2017fTP12014 Matrix-R Weight: 71 lb FT = 20%F, 11 %E LUMBER- BRACING- TOPCHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3(flat) REACTIONS. All bearings 15-11-8. lb) - Max Grav All reactions 250 lb or less at joint(s) 26, 14, 20, 15, 16, 17, 18, 19, 25, 24, 23, 22, 21 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) All plates are 1x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strong backs, an edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MR-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(g) connectors. This design is based only upon parameters shown, and is for an indmdual building component, not a truss system. Before use, the building designer must venfy the applicability of design parameters and properly incorporate this design into the overall I ing design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracingildwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regarding the Nd G-1w, isa fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944449 IP2078AC-T F3 ROOFTRUSS 1 all Mid-Flonda Lumber, bar -tow, t- L. i 1-3-0 j. 1,11J S )ep I D ZU I I IVII I eK IFICILIbUleb, MU. 1-11 Jd11 I Z -.-- zU 10 -Y , ID:qR7GTqtGeHxJkx7yRAMor5yENix-aPyX_VW6YAYuQCQCQsTudT42Pt6izmW?31—SbQzw9oP 1-2-8 0-48 Scale = 1:261 3X3 3x3 1 X3 3x3 3x3 3X3 4X6 1 4X6 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 9 3X3 45 3x3 3x3 1 x3 3x3 3x3 4X4 3x3 i 12-11-8 15-8-810-5-82221:19 5-2-8 2-9-0 Plate Offsets (X,Y)— [17Edge,0-1-81 LOADING (psfi SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCILL 40.0 Plate Grip DOL 1.00 TC 0.56 Vert(LL) -0.16 12-13 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.73 Vert(CT) -0.21 12-13 >874 240 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(CT) 0.04 9 n/a n/a BCDL 5.0 Code FBC2017/TP12014 Matrix-S Weight: 83 lb FT = 20%F, 11 %E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No. I (flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 17=850/Mechanical, 9=850/Mechanical FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-1 7=-846/0, 8-9=-844/0, 1-2 844/0, 2-3=-2011/0, 3-4=-2691/0, 4-5=-2691/0, 5-6=-2599/0, 6-7=-202610, 7-8=-839/0 BOTCHORD 15-16=0/1 584, 14-15=0/2431, 13-14=0/2691, 12-13=012691, 11-12=0/2449, 10-11 =0/1 580 WEBS 8-1 0=0/1 117, 1-16=0/1 123, 7-1 0=-1 030/0, 2-16 1 030/0, 7-11 =0/620, 2-1 5=0/594, 6-11 =-589/0, 3-15=-583/0, 6-12=01312, 3-14=0/538, 5-12=-338/112 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strong backs, on, edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARAIING - Verify design parameters andREAD NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Mi7ekID connectors. This design is based only upon parameters shown, and is for an individual building component, not atwss system. Before use,the building designer must erify the applicability ofdesign parametersand properly incorporate this design intothe overall building design. Bracing indicated is to prevent buckling of ndivdual truss web andJor chord members only. Additional temporary and pe"anent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of twsses and tnuss systems, see ANSltTPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Last Blvd. Safety Inforntation available from Truss Plate Institurle, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944450 P2078AC-T F3G ROOFTRUSS 1 Job Reference (ontional) mia-rionaa LUmoer, barlOW, t-L. i 1-3-0 P:6:9_1 6.1 JU s bep It) ZUI I Mi I eK InOuStneS, Inc. Vn Jan 12 1.11:49:24 ZUI 6 Hage 1 ID:qR7GTqtGeHxJkx7yRAMor5yENIx-aPy)_VVV6YAYuQCQCQsTudT4zFt6JziU?31_SbQzw9oP 1-5-8 Scale = 1:26.1 1X3 11 w 3X7 3x3 3x3 3x3 3x3 4X6 1 5x6 2 3 9 20 19 18 17 16 15 14 13 12 11 10 3X3 4x5 = 3x4 3X3 3x3 3x3 1 x3 1 X3 3X3 4x5 3X3 12 21-12 12-1-0 Plate Offsets (X,Y— [1:Edge,0-1-81, [18:0-1-8,Edgel, [19:0-1-8,Edgel LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.89 Vert(LL) -0.21 14-15 >865 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.71 Vert(CT) -0.29 14-15 >633 240 BCLL 0.0 Rep Stress Incr NO WB 0.79 Horz(CT) 0.04 10 n/a n/a BCDL , 5.0 Code FBC2017fTPI2014 Matrix-S Weight: 87 lb FT = 20%F, 1 1%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 5-2-7 oc purlins, BOTCHORD 2x4 SP DSS(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 20=981 /Mechanical, 10=888/Mechanical FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-20=-1 066/0, 9-1 0=-887/0, 1-2=-1 274/0, 2-3=-1 274/0, 3-4=1 274/0, 4-5=-2648/0, 5-6=2936/0, 6-7=-2760/0, 7-8=-2137/0, 8-9=-885/0 BOTCHORD 18-19=0/1274, 17-18=0/2353,16-17=012353, 15-16=0/2950, 14-15=0/2760,13-14=0/2760, 12-13=0/2760, 11-12=0/1651 WEBS 4-17=01353, 1-19=0/1664, 4-18=-1429/0, 2-19=-517/0, 3-18=0/339, 9-11=0/1179, 4-16=01398, 8-11=-1064/0, 5-16=-427/0, 8-12=0/676, 7-12=-897/0, 6-15=0/417, 6-14=-357/0, 7-13=0/380 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 169 lb down at 3-7-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. - 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plo Vert: 10-20 10, 1-9=-100 Concentrated Loads (lb) Vert: 17=-169(F) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNiNG - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111411-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekS connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indiidual truss web and/or chord members only. Additional temporary and pe—anenl bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the rk East Blvd fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSlrrPl1 Quality Criteria, DSB-89 and BCSI Building Component 69G4 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. T=mpa, FL 36610 Job Truss Truss Type Qty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944451 P2078AC-T F4 ROOF TRUSS 5 Job Reference (optional) mia-rionaa LumDer, t3anow, t-L. 0_1_8 H 1-3-0 14 13 3x3 0. IOU 5 Oep 10 ZU I/ VIN I eK I FIUU51.[Rl, I 11C. 1-11 Jdl I I Z U1.4V.Z3 zu 10 rdye I ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-2bWvCrXIJUhl2M?O-Z?7AhcFiHY?iHQ81hk?8szw9oO I Scale= 1: 18.1 3X3 1x3 1 x3 3x3 2 3 4 5 3x8 6 lx 1x3 3x3 11 10 9 8 1-1 — IxI 1 x3 11 3x3 11 LOADING (psf) SPACING- 2-G-0 CS1. DEFL. in loc) Weft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.40 Vert(LL) -0.04 8-9 >999 360 MT20 244/1.90 TCDL 10.0 Lumber DOL 1.00 BC 0.37 Vert(CT) -0.05 8-9 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.30 Horz(CT) 0.01 7 n/a n/a BCDL 5.0 Code FBC2017rTP12014 Matrix-S Weight: 53 lb FT = 20%F, 11 %E LLIMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 1-12,6-7: 2x4 SP No.2(flat) REACTIONS. (lb/size) 12=529/0-8-0,7=529/0-3-8 FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-12=-525/0, 6-7 525/0,1-2=-455/0,2-3 1029/0,3-4=1029/0, 4-5=-102910, 5-6=-474/0 BOTCHORD 10-11=0/865, 9-10=0/1029,8-9=0/880 AIEBS 6-8=0/631, 1-11=0/618, 5-8=-566/0,2-11=-571/0, 5-9=0/341, 2-10=0/354 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. Printed copies of this document are not considered, signed and sealed and the signature must be verified on any electronic copies A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473— 1010312015 BEFORE USE Design valid for use only with MiTek(D connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only, Additional temporary and permanent bracing ro ff'dwisalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regarding the fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIrFPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Instilute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq Hms/ Sorrento-AorC 2078 T1294445 P2078AC-T F4A GABLE 1 ah mia-t-ionaa Lumber, bartow, t-L. 34 1x3 1 2 Ci F1 i.i.iu s ep i zui i Nni ieK mousines, mc. rn jan iz ut:4 vzo zwo vage I ID:LwgEfgAbgYkKfRKdr2TZXPzS7xJ-Wo4HPAYN4opcgWabYHWMiu9VFhzmRos[WLTZgJzv4goN S ale = 1: 17.5 1 x3 i X3 i X3 11 1 x3 1 x3 i X3 3x3 3 4 5 6 7 8 9 18 17 16 3X3 11 1 X3 11 10 11 15 14 13 1X3 11 IX3 11 1 x3 11 12 11 10 1 X3 11 1 x3 11 3X3 11 9 LOADING (psf) SPACING. 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.08 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(CT) n1a n/a 999 BCLL 0.0 Rep Stress Incr YES VVB 0.03 Horz(CT) 0.00 10 n/a n/a BCDL 5.0 Code FBC2017fTPl2014 Matrix-R Weight: 46 lb FT = 20%F, 11 %E LUMBER. BRACING- TOPCHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3(flat) REACTIONS. All bearings 9-6-12. lb) - Max Grav All reactions 250 lb or less at joint(s) 18, 10, 14, 11, 12, 13, 17, 16, 15 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Gable requires continuous bottom chord bearing. 2) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 3) Gable studs spaced at 1-4-0 oc. 4) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekS connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 10 a -awl fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Nexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Sq Hms/ Sorrento-AorC 2078Park T12944453 P2078AC-T F5 ROOFTRUSS 1 Job Reference Iootional) mio-rioncla LUMDer, UaROW, rL. 0-1-8 H 1 1-3-0 3x3 3x6 ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-xg3Wu6rFx4cBHsqXQlCwIO—luXb8nZ_pl8gG42zw4S4 i 1-1-8 0 Scal el:19.6 3x4 3x3 1 x3 i X3 3x3 3x4 = 3x3 2 3 4 5 6 16 7 17 8 1 1-6-14 1-2-2 1 6-4-8 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d TCLL 40.0 Plate Grip DOL 1.00 TC 0.98 Vert(LL) 0.08 10-11 999 360 TCDL 10.0 Lumber DOL 1.00 BC 0.83 Vert(CT) 0.11 10-11 999 240 BCLL 0.0 Rep Stress Incr NO WB 0.36 Horz(CT) 0.02 9 n/a n/a BCDL 5.0 Code FBC2017/TP12014 Matrix-S 3X6 = PLATES GRIP MT20 244/190 Weight: 65 lb FT = 20%F, 11 %E LUMBER- BRACING- TOPCHORD 2x4 SP No.l(flat) TOPCHORD Structural wood sheathing directly applied or 4-10-14 oc puffins, BOTCHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. lb/size) 15=601/1-10-8, 9=963/Mechanical, 14=1 17/0-3-8 Max Grav 15=601 (LC 1), 9=1 128(LC 8), 14=1 17(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1 034/0, 3-4=1 746/0, 4-5=-1 746/0, 5-6=-1 74610, 6-7=-1 518/0 BOT CHORD 14-15=0/666, 13-14=0/666, 12-13=0/1482, 11-12=0/1746, lo-1 1=0/1833, 9-1 0=0/1 150 WEBS 7-9=-1530/0, 2-15=-887/0, 7-10=0/572, 2-13=0/529, 6-10=-519/0, 3-13=-638/0, 6-11 =-363/263, 3-12=0/593, 4-12=-280/0 NOTES- -11 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 347 lb down at 8-11-4, and 349 lb down at 10-11-4 on top chord. The design/selection of such connection device(s) is the responsibility of others. 5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber lncrease=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 9-15=-1 0, 1-8=-1 00 Concentrated Loads (11b) Vert: 16 201(B) 17=-202(B) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verity des ign parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(b connectors. This design is based only upon parameters shown, and is for an indivdual building component, not a truss system. Before use,,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indiodual truss web andlor chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944454 P2078AG-T F6 ROOFTRUSS 2 Job Reference (ootional) mia-t-ionaa Lumber, bartoW, I-L. 0-1-8 d 10 9 8,13U s 6ep 1!) ZU I I MI I eK I nclustnes, Inc. t-n Jan I Z U/:4V:Z I ZU I b Flage i ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-_efdWZ?r5xTHg9n6 IbF6ifr5lhAExRI?D6CIzw9oM 3x6 0-10-12 3 4 1.3 11 3X3 11 Scale = 1:9.4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.13 Vert(LL) 0.00 6 999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.10 Vert(CT) 0.01 6 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.11 Horz(CT) 0.00 5 n/a n/a BCDL 5.0 Code FBC2017rrPI2014 Matrix-S Weight: 26 lb FT = 20%F, 11 %E LLIMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 4-1-12 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=21 1 /G-7-4, 5=21 I/Mechanical FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(& connectors. This design is based only upon parameters shown, and is for an indivdual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buclding of indivdual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the W, fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Type aty Ply Park Sq Hms/ Sorrento-AorC 2078Truss T12944455 P2078AC-T F7 ROOFTRUSS 1 1 Job Reference (optional) Ivid-Flonda Lumber, Bartow, FL. 8.130 S Sep 15 2U17 Milek Industries, Inc. Fn Jan 12 01:49:21 ZU18 Page 1 ID:qR7GTqtGeHxJkx7yRAMor5yENIx--efdWZ?r5xTHg9n6—lbF6igd5lAAEIRI?D6CIZW9oM 1-3-0 3x6 1 3x6 2 1 x3 11 3 1x3 11 4 Scale = 1 9.4 3x3 3x3 8 7 6 5 3X3 11 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Lid TCLL 40.0 Plate Grip DOL 1.00 TC 0.12 Vert(LL) 0.00 7 999 360 TCDL 10.0 Lumber DOL 1.00 BC 0.06 Vert(CT) 0.00 7 999 240 6CLL 0.0 Rep Stress Incr YES VVI3 0.08 Horz(CT) 0.00 5 n/a n/a BCDL 5.0 Code FBC2017/TPI2014 Matrix-S LUMBER- BRACING- 3X3 11 PLATES GRIP MT20 244/190 Weight: 25 lb FT = 20%F, 11 %E TOP CHORD 2x4 SP No.2(flat) TOPCHORD Structural wood sheathing directly applied or 3-6-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. AIEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=179/Mechanir-al, 5=179/Mechanir-al FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies 9MMMMMEMEMM= WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 r— 1010312015 BEFORE USE. Design validforuse onlywith MiTelk0connectors. This design isbased onlyupon parameters shmn, and isforan individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss eb and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse fth possible personal injury and property damage. For general guidance regarding the fabricalion, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 69G4 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T129444 P2078AC-T FT1 SPECIAL 1 3 all mia-t-ionaa LUMDer, bartow, t-L. C. 13U 5 Otp I D ZU I 1 101 1 UK muubuicb, ui. — Jdl I - U-V- ZU 10 r-dyU , ID:qR7GTqtGeHxJkx7yRAMor5yENIx-wNmQ2CaFNjBBX JADP33KXnoXum5exVkCJiDHdzw9oK 2- 1-1 14-11-4 16:34 1 1 11 1 1 2 1 7-'13 4-4-'2 7 7 9-IMjL5-6: -0 1'. 2' l T.15 21-1 21-E 4-04 2" 2_1 Scale = 1 50.8 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 504 4)(4 1.5x4 3X8 1.5x4 4x10 = 8xl4 MT20HS = 4xl2 3X8 1.5x4 3xl 0 1.5X4 300 1 2 3 26 27 4 5 6 7 8 28 9 10 29 30 11 12 13 2X4 4x8 2X4 11 4x12 5x12 5X6 7x8 6x10 4x12 2X4 11 7x10 4X4 2-10- 1 ': 1 1 11 i IT31:160 16:3-4 i I 2 1 1 2_4-52 7 1 2 n-82-16-1 NMI 1 1 1 7-513 O7 2 1 2 5 2-_110-1 Plate Offsets (X,Y)-- 570-3-8,0-2-01, [8:0-3-8,0-2-01, [970-3-8,0-1-81, [147Edge,0-3-81, rl 570-2-8,0-3-121, [18:0-3-8.0-3-01, [19:0-3-0,0-4-81, [21:0-3-8,0-2-81, [22:0-3-0,0-1-1 2L_ LOADING (psf) SPACING- 2-G-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.99 Verl(LL) -0.26 17 >733 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 Elc 1.00 Vert(CT) -0.39 16-17 >491 240 MT20HS 187/143 8CLL 0.0 Rep Stress Incr NO WB 0.93 Horz(CT) 0.01 14 n1a n/a BCDL 5.0 Code FBC2017rrP[2014 Matrix-S Weight: 496 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No. 1 *Except* TOPCHORD Structural wood sheathing directly applied or 1-4-12 cc purlins, 6-13: 2x4 SP DSS except end verticals. BOTCHORD 2x6 SP No.1 BOTCHORD Rigid Ceiling directly applied or 2-2-0 cc bracing. WEBS 2x4 SP No.3 *Except* 7-20,7-19: 2x4 SP No.1 1-24,3-24,3-22,5-22,6-21,8-18,9-17,11-17,11-15,13-15: 2x4 SP No. 1 D REACTIONS. (lb/size) 25=175610-7-4,14=3401/G-7-4,20=1580510-7-7 Max Uplift 25=-218(LC 4), 14 365(1_C 5), 20 1838(!_C 8) MaxGrav 25=1756(LCI),14=4237(LC2),20=17511(LC2) FORCES. (lb) -Max. Corri Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-25 1 565/202, 1-2=-3824/457, 2-3=-3824/457, 3-4=-40701535, 4-5 4070/535, 5-6=-591/5654,6-7 2118/20913,7-8=-184/1798,8-9 11159/1220,0-10=-16867/1693, 10-11=-16867/1693,11-12=-9811/841,12-13=-9811/841,13-14 3682/338 BOTCHORD 24-25=-331257, 23-24=-705/6310, 22-23=-705/6310, 21-22=-5654/591, 20-21=-20913/2118,19-20 1 1422/1111, 18-19 1798/184,17-18=-1220/11159, 16-17 1488/16115,15-16 1488/16115,14-15=-50/567 WEBS 8-19=-6491/769, 6-20 7928/942,7-20 1 1695/1241, 7-19 1200/11857,2-24=-710/109' 3-23 5/1004, 4-22=-2218/317, 5-21 =-5279/672, 12-15=-644/105, 11-16 1 1/1253, 10-1 7 2044/294, 9-18=-3888/498, 1-24=-45013797, 3-24=-2638/263, 3-22=-2377/209, 5-22 1 037/10322, 6-21 =-I 681/16197, 8-18 1 370113756, 9-17 51916058, 11 -1 7 251/1355, 11-15=-6692/687, 13-15 840/9812 NOTES- 1) 3-plytrussto be connected together with 10d (0.131"x3") nails asfollows: Top Chords connected as follows: 2x4 - 1 row at 0-7-0 cc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 cc. Webs connected as follows 2x4 - 1 row at 0-7-0 cc, Except member 20-7 2x4 - I row at 0-0-0 cc, member 7-19 2x4 - 1 row at 0-9-0 cc, member 2-24 2x4 - 1 row at 0-9-0 oc, member 3-23 2x4 - 1 row at 0-9-0 cc, member 4-22 2x4 - 1 row at 0-9-0 cc, member 5-21 2x4 - I row at 0-9-0 cc, member 12-15 2x4 - 1 row at 0-9-0 cc, member 11-16 2x4 - 1 row at 0-9-0 cc, member 10-17 2x4 - 1 row at 0-9-0 cc, member 9-18 2x4 - 1 row at G-9-0 cc, member 1-24 2x4 - 1 row at 0-9-0 oc, member 24-3 2x4 - 1 row at 0-9-0 oc, member 3-22 2x4 - 1 row at 0-0-0 cc, member 22-5 2x4 - 1 row at 0-9-0 cc, member 6-21 2x4 - 1 row at 0-9-0 cc, member 18-8 2x4 - I row at 0-9-0 cc, member 9-17 2x4 - 1 row at 0-9-0 cc, member 17-11 2x4 - 1 row at 0-9-0 cc, member 11-15 2x4 - I row at 0-9-0 oc, Printed copies of this document aremember15-13 2x4 - 1 row at 0-9-0 cc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. ply to not considered signed and sealed and ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. the signature must be verified on 3) \Alind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=15ft; B=45ft; L=30ft; eave=4ft; Cat. any electronic copies 11 Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 4) rovide adequate drainage to prevent water ponding. ESSIMM CARtW'y#Ah@-PAQ&9esjgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with VrTek0 connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing Melisalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalinjuryandproperlydamage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPIl Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Instilule, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sci Hms/ Sorrento-AorC 2078 T12944456 P2078AC-T FT1 SPECIAL 1 3 Job Reference optional) Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Jan 12 07:49:29 2018 flage 2 ID:qR7GTqtGeHxJkx7yRAMor5yENix-wNmQ2CaFNjBBX—JADP33KXnoXum5exVkCJiDHdzwgoK NOTES- 6) NIA 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 218 lb uplift at joint 25, 365 lb uplift at joint 14 and 1838 lb uplift at joint 20. 10) Girder carries tie-in span(s): 3-0-0 at 0-0-0 to 7-0-0 at 7-0-0.; 7-0-0 at 22-10-8 to 3-0-0 at 29-10-8.; 27-0-0 from 7-0-0 to 17-0-0; 25-2-8 from 17-0-0 to 23-0-0 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 840 lb down at 8-1-8, 854 lb down at 10-1-8, 854 lb down at 11-9-8, 854 lb down at 13-9-8, 854 lb down at 15-9-8, 854 lb down at 17-9-8, 854 lb down at 19-9-8, 854 lb down at 21-9-8, 854 lb down at 23-9-8, 854 lb down at 25-9-8, 854 lb down at 27-9-8, and 169 lb down at 5-1-0, and 971 lb down at 6-1-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=11.00 Uniform Loads (plo Vert: 26-28=-895, 28-30=-845, 14-25=-10 Concentrated Loads (11b) Vert: 14=-1 2 20=-226(B) 22=-222(B) 17=-226(B) 31 =-39(B) 32=-253(B) 33=-226(B) 34=-226(B) 35=-226(B) 36=-226(B) 37=-226(B) 38=-226(B) 39=-226(B) 40=-226(B) Trapezoidal Loads (plf) Vert: 1 235-to-26=-345, 30=-345-to-13=-235 M WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(b connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall R buildingdesign. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 10 1 .. I fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Infonmation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Ale.andria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T129444 P2078AC-T FT2 SPECIAL 1 3 all mia-f,ionoa LUmoer, Bartow, t- L. b.iit.; s bep it) 2ui / mi i eK inoustnes, Inc. vn jan 12 U/:4V:ZV Z1.116 Hage i I D:LwgEfgAbgYkKfRKdr2TZXPzS7xJ-wNmQ2CaFNjBBX — JADP33KXnpruoweyDkCJiDHdzw9oK 3-6-14 -6 13-2-12 16-7-14 20-_2-22-0 01 3-6-14 T-1 3-1-6 _5_2 _114 7x8 1.5x4 11 6x8 = 1.5x4 11 7x8 1 2 15 3 16 17 4 18 5 1.5x4 11 4x8 19 6 7 Scale = 1:34.2 14 8 5x5 Sx14 MT20HS 8xl 0 MT20HS 7X8 2x4 11 6x1 0 3x4 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 7 10-1-6 1 2 7-14 20-2-121B_ 3 3-1-6 3-12 1 3-_5-2 3-6-14 Plate Offsets (X,Y)— f5:0-4-0,0-3-4l,[12:0-5-0,EdQel LOADING (psf) SPACING- 1-8-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.90 Vert(LL) -0.60 11-12 >399 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 Bc 0.88 Vert(CT) -0.82 11-12 >291 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr NO W13 0.89 Horz(CT) 0.07 8 n/a n/a BCDL 5.0 Code FBC2017/TPI2014 Matnx-MS Weight: 332 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP DSS *Except* TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, 5-7: 2x4 SP No.2 except end verticals. BOTCHORD 2x6 SP DSS BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 *Except* 1-13,7-9,3-13,5-9: 2x4 SP No.1 REACTIONS. (lb/size) 14=4419/0-7-4, 8=2866/0-3-8 Max Uplift 14=-628(LC 4), 8 400([_C 5) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-14=-3963/572, 1-2=-1 3244/1877, 2-3=-1 3244/1877, 3-4=-23032/3199, 4-5=-23032/3199, 5-6=-8641/1203, 6-7=-8641/1203, 7-8=-2484/355 BOTCHORD 13-14=-123/855, 12-13 3388/24064, 11-12=-3388/24064, 10-1 1=-2456/17683, 9-1 0=-2456/17683, 8-9 76/530 WEBS 1-1 3=-1 821/12864, 3-11 =-I 081/198, 4-11 =-1 907/285, 5-11 =-832/5596, 5-1 0=-65/603, 7-9 1 170/8423, 2-13=-766/139, 3-13=-1 1236/1591, 5-9=-9389/1321 NOTES- 1 ) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf ' BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat. 11 Exp B; Encl., GCpi=0.18 MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 4) rovide adequate drainage'to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 628 lb uplift at joint 14 and 400 lb uplift at joint 8. 9) Girder carries tie-in span(s): 2-4-0 at 0-0-0 to 6-8-0 at 7-0-0. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 847 lb down and 122 lb up at Printed copies of this document are 10-2-0, and 1888 lb down and 273 lb up at 7-0-0, and 1073 lb down and 155 lb up at 9-0-0 on top chord. The design/selection of not considered signed and sealed and such connection devi*s) is the responsibility of others. the signature must be verified on LOAD CASE(S) Standard any electronic copies WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PA E M11-7473 rei, 1010312015 BEFORE USE. Design valid for use only with MiTeklD connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system, Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M_ - Nowisalwaysrequiredforstabilityandtopreventcollapsewilhpossiblepersonalinjuryandproperlydamage. For general guidance regarding the fatincation, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 arke East Blvd. fetSa y Inforinnation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tamppa, FL 36610 Job Truss Truss Type Qty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944457 P2078AC-T FT2 SPECIAL 3 Job Reference foptional) Mid-Flodda Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Jan 12 07:49:30 2018 Page 2 ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-PZKoFYbt7OJ287uMn7altkK—bl79NPTtP,zRmp4zv,r9oJ LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 3-4 207, 4-7=-83, 8-14=-8 Concentrated Loads (lb) Vert: 3=1888 4 847 17 1073 Trapezoidal Loads (plf) Vert: I 208-to-3=-327 A WARNING - V.Hfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekS connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indimclual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPI1 Quality Criteria, DSB-89 and BCSI Building Component 69G4 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA223i4. Tampa, FL 36610 7 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944458 P2078AC-T FT3 FLOOR 1 1 all Mid -Florida Lumber, Barlow, FL. o. lou b oup 13 20 1 1 ivl 1 EK!FluusL es, mic. jaiii !z u1:"V:0ur zu Fu age 1 ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-PZKoFYbt7 J'287uMn7aitkKBPIJV,/NcLtRzRmp4zw,9oJ 1-10-0 1-10-0 1 3x4 2 1.5x4 Scale = 1:9.5 2X41 11 4x4 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) Ildefl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.08 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.09 Vert(CT) -0.00 4 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 5.0 Code FBC2017/TPI2014 Matrix -MP Weight: 11 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 1 -10-0 oc purlins, BOTCHORD 2x6 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=172/0-3-8, 3=177/Mechanir-al FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown NOTES- 1) Refer to girder(s) for truss to truss Connections. 2) Recommend 2x6 strong backs, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strong backs to be attached to walls at their outer ends or restrained by other means. 3) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 179 lb down at 0-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 4) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate lncrease=1.00 Uniforni Loads (plf) Vert: 1-2=- 100, 3-4 10 Concentrated Loads (11b) Vert: 5 179fl Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies EMMISM11ZEMEEM AWARNING- Vertlydesign parameters and READ NOTES ON THIS AND INCLUDED MrTEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(b connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the M_ Me 7i fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSlITPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Pan, Sq Hms/ Sorrento-AorC 2078 T12944459 P2078AC-T FT4 ROOFTRUSS 1 2 Ivid-Flonda Lumber, Bartow, FL. 8.130 s Nov 13 2017 MiTek Industries, Inc. Fn Jan 12 10:41:52 2016 Page I ID: LwgEfgAb9YkKfRKdr2TZXPzS7xJ-LxU 1 x2 NI NsUMvxIjmSic1_ EYB_2CX 'I gnFmucV,/Rlzw88z 3-4-5 6-6-15 9-11-4 3-4-5 3-2-9 3-4-5 Scale = 1: 18.4 2X4 4x8 2 3 4x4 10 2X4 4 4X6 = 4x6 = 3-4-5 6-6-15 9-11-4 3-4-5 3-2-9 3-4-5 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/clef! L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.72 Vert(LL) -0.05 6-7 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.75 Vert(CT) -0.12 6-7 >995 240 BCLL 0.0 Rep Stress Incr NO WB 0.55 Horz(CT) 0.02 5 n1a n/a BCDL 105.0 Code FBC2017ITP12014 Matrix -MS Weight: 109 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 5-6-13 oc purlins, BOTCHORD 2x6 SP No.1 except end verticals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8= 1530/0-7-4, 5= 1559/0-5-8 Max Uplift 8=-76(LC 4), 5 77(!_C 5) Max Grav 8=1825(LC 2), 5=2101(LC 2) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-326/17, 2-3=-4487/161, 3-4=-412/18 BOTCHORD 7-8=-165/4443, 6-7=165/4443, 5-6=-161/4487 WEBS 2-8=-4295/154, 2-7=0/1 124, 3-6=0/1 182, 3-5=-4251/150 NOTES- 1) 2-plytrussto beconnected togetherwith 10d (0.131"x3") nails asfollows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft, eave=4ft; Cat. 11; Exp B, Encl., GCpi=O.l 8; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 76 lb uplift at joint 8 and 77 lb uplift at joint 5. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 22 lb down and I lb up at 8-1-8, and 773 lb down at 4-4-4, and 678 lb down at 8-1-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate lncrease=1.00 Uniform Loads (plf) Vert: 1-4 100, 5-8=-210 Concentrated Loads (lb) Vert: 11 46(13) 12=-53(F=-22, B=-31) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verilyd..ig.p.rametem and READ NOTES ON THIS AND INCLUDED MITEKREFERENCE PAGE Mil-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekaD connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the,building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 10 fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job russ Type Qty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944460 P2078AC-T J3 Truss JACK 3 1 Job Reference (optional) mia-vionaa LumDer, barlow, V L. 6.13U s bep 1b 201 / Mil elk Industries, Inc. Fn Jan 12 01:4Y::31 2U18 Page 1 ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-HtASucVuKRvmHTYLq5XPysKaiev63blgdBKLmwgoI 3-0-0 3-0-0 Scale = 1: 15.7 2x4 11 3-0-0 3-0-0 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.25 Vert(LL) 0.01 4-5 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.14 Vert(CT) -0.01 4-5 >999 180 BCLL 0.0 Rep Stress Incr YES WS 0.00 Horz(CT) -0.01 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MR Weight: 12 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, BOTCHORD 2x4 SP No.2 except end verticals. WEBS 2x4i SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=195/0-8-0, 3=69/Mechanical, 4=28/Mechanical Max Horz 5=78(LC 12) Max Uplift 5=-47(LC 12), 3=-54(LC 12), 4=-5(LC 12) Max Grav 5=195(LC 1), 3=85(LC 17), 4=52(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=1 40mph (3-second gust) Vasd=1 08mph; TCDL=4.2psf; BCDL=3.Opsf, h=1 5ft, B=45ft; L=24ft; eave=4ft, Cat. 11, Exp B; Part. Encl., GCpi=0.55; M\A/FRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interion(l) 2-0-0 to 2-11-4 zone,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47 lb uplift at joint 5, 54 lb uplift at joint 3 and 5 lb uplift at joint 4. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 re, 1010312015 BEFORE USE, AW—_ Design valid for use only with Mrrekili) conneclors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq HITS/ Sorrento-AorC 2078 T12944461 P2078AC-T J7 JACK 26 Job Reference (ootionah Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTelk Industries, Inc. Fri Jan 12 07:49:32 2018 Page I ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-LyRYgEcBfeZmOR2luXdmy9POD6uurWqAvHv,tuyzvdgoH 1-0-0 7-0-0 7-0-0 Scale = 1 21 8 3X4 = LOADING (psf) SPACING- 2-0-0 CS1. TCLL 20. 0 Plate Grip DOL 1.25 TC 0.70 TCDL 0.0 Lumber DOL 1.25 BC 0.54 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=183/Mechanical, 2=342/0-3-8, 4=90/Mechanical Max Horz 2=141 (LC 12) Max Uplift 3=-93(LC 12), 2=-82(LC 12) Max Grav 3=183(LC 1), 2=342(LC 1), 4=129(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. DEFL. in (loc) I/defl L/d PLATES GRIP Vert(LL) 0.12 4-7 >679 240 MT20 244/190 Vert(CT) -0.24 4-7 >348 180 Horz(CT) 0.00 2 n/a n/a Weight: 24 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf. BCDL=3.Opsf; h=25ft, B=45ft, L=24ft; eave=4ft, Cat. 11; Exp B, Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterior(2) -1 -0-0 to 2-0-0, Interior(l) 2-0-0 to 6-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 93 lb uplift at joint 3 and 82 lb uplift at joint 2. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies A WARNING -Verify design,parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473— 1010312015 BEFORE USE. Design valid for use only with ViTek@ connectors. This design is based only upon parameters shown, and is for an individual building component, not a ystem. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overalltruss " 10 UUMbuildingdesign. Bracing indicated is to prevent buckling of inchAdual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabncation, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCS] Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss fuss Type Qty Ply Park Sq HITS/ Sorrento-AorC 2078 JACK T12944462 P2078AC-T J7T 3 Job Reference Ootiona mia-Honaa LUmDer, bartow, 1- L. 1 6'1'5u s z ep I o zui t mi I eK inaustries, inc. t- n jan I z u t:4v:,iz zui ts Fage I ID:LwgEfgAbgYkKRKdr2TZXPzS7xJ-LyRYgEc8feZmOR2luXdmy9PLr6sbrWqAvHvAuyzw9oH 7-0-01 7-0-0 3x4 2X4 11 I-; Srale = 1:22.9 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in loc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.86 Vert(LL) 0.19 6 >432 240 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.69 Vert(CT) -0.32 6 >258 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.16 5 n/a n/a BCDL 10.0 Code FBC2017frPI2014 Matrix -MR Weight: 26 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-9-12 oc purlins. BOTCHORD 2x4 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. 3-7: 2x4 S P No. 3 REACTIONS. (lb/size) 4=169/Mechanical, 2=346/0-8-0, 5=107/Mechanical Max Horz 2=141(LC 12) Max Uplift 4=-79(LC 12), 2=-81 (LC 12), 5=-1 3(LC 12) Max Grav 4=169(LC 1), 2=346(LC 1), 5=126(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft, L=24ft; eave=4ft; Cat. 11, Exp B; Encl., GCpi=0.18 M\/VFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 6-11-4 zone;C-C for members and forces & M4RS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 4, 81 lb uplift at joint 2 and 13 lb uplift at joint 5. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 110111-7473 r— 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system, Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MEN, fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Inforniation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job _Truss_ Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944463 P2078AC-T KJ2 JACK 1 Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. I'd Jan 12 07:49:33 2018 Page 1 ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-p8?xtadmQxhdObdxSF8?VNyhlWM_az4K7xgQQPzw9oG 1-5-0 2-4-5 Scale = 1:8.6 2x4 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defi L/d PLATES GRIP TCLIL 20.0 Plate Grip DOL 1.25 TC 0.14 Vert(LIL) -0.00 7 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.04 Vert(CT) -0.00 7 >999 180 BCLIL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 10 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 2-4-5 oc puffins. BOTCHORD 2x4 SO No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=44/Mechanical,2=202/0-5-11,4=19/MechanicaI Max Horz 2=52(LC 8) Max Uplift 3=-14(LC 8), 2=97(LC 8) Max Grav 3=44(LC 1), 2=202(LC 1), 4=37(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft, Cat. 11; Exp B; Encl., GCpi=0.18 ' MWFRS (directional); Lumber DOL=1.60 plate grip DOL=11.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3 and 97 lb uplift at joint 2. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 9 lb up at 1-6-12, and 3 lb down and 9 lb up at 1-6-12 on top chord, and 2 lb up at 1-6-12, and 2 lb up at 1-6-12 on bottom Chord. The design/seiection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3 60, 4-5=-20 Concentrated Loads (lb) Vert: 9=4(F=2, B=2) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTelkili) connectors. This design is based only upon parameters shown, and is for an indimclual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indiAdual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Infornnation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Trus Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T1 29444 P2078AC-T KJ3 JACK 2 all mia-t-ionoa Lumaer, banow, t-L. 1 o. iou s oep 10 ZU I 1 1011 eK I rIC11.15t[ItS, 1 [IQ. 1-11 JdIl 14 U1.4- ZU 10 I-dy I ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-p8?xtadmQxhdObdxSFS?VNyhzWK2az4K7xgQQPzw9oG 1-5-0 4-2-15 5 1.5x4 Scale = 1: 15.4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.19 Vert(LL) -0.01 4-5 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 Bc 0.16 Vert(CT) -0.02 4-5 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) -0.01 3 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MR Weight: 16 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SID No.2 TOPCHORD Structural wood sheathing directly applied or 4-2-15 oc purlins, BOTCHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=226/0-11-5, 3=84/Mer-hanical, 4=34/Mer-hanical Max Horz 5=79(LC 8) Max Uplift 5=-124(LC 8),3=-73(LC 8),4 7(1_G 8) Max Grav 5=226(LC 1), 3=84(LC 1), 4=70(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf, h=15ft, B=45ft, L=24ft; eave=4ft, Cat. 11; Exp B; Part. Encl., GCpi=0.55; MWFRS (directional), Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 124 lb uplift at joint 5, 73 lb uplift at joint 3 and 7 lb uplift at joint 4. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support Concentrated load(s) 100 lb up at 1-6-12, and 100 lb up at 1-6-12 on top chord, and 12 lb up at 1-6-12, and 12 lb up at 1-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5 20 Concentrated Loads (lb) Vert: 6=64(F=32, B=32) 7=10(F=5, B=5) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(b wrtnectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indiAdual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabiication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Adexandria, VA 223M. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944465 P2078AC-T KJ7 JACK 7 Job Reference (optional) Mid-Floncla Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Jan 12 07:49:34 2018 Page I ID:LwgEfgAb9YkKfPKdr2TZXPzS7xJ-HKZJ5weOBFpTdIB70yfElaUpovr-2JLgTMbP_yFzw9oF 1-5-0 5-2-5 9-10-13 1-5, 5-2-5 4-8-8 Scale = 1:21.9 2x4 1X4 11 5 3x4 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) 11defl L/d PLATES GRIP TCLL 20.0 Plate Grip COL 1.25 TC 0.38 Vert(LL) -0.03 6-7 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.43 Vert(CT) -0.07 6-7 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.36 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017frPI2014 Matrix -MS Weight: 42 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=128/Mechanical, 2=51110-5-11, 5=328/Mechanical Max Horz 2=142(LC 8) Max Uplift 4 70(1-C 8), 2 148(LC 8), 5 69([-C 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-775/136 BOTCHORD 2-7=-208T708, 6-7=-2081708 WEBS 3-7=0/275. 3-6 769/225 NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf, BCDL=3.Opsf; h=25ft; B=45ft, L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 4, 148 lb uplift at joint 2 and 69 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 11 lb up at 1-6-12, 3 lb down and 11 lb up at 1-6-12, 3 lb down and 44 lb up at 4-4-12, 3 lb down and 44 lb up at 4-4-12, and 27 lb down and 77 lb up at 7-2-11, and 27 lb down and 77 lb up at 7-2-11 on top chord, and 2 lb up at 1-6-12, 2 lb up at 1-6-12, 5 lb down at 4-4-12, 5 lb down at 4-4-12, and 20 lb down at 7-2-11, and 20 lb down at 7-2-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the fare of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-60, 5-8=-20 Concentrated Loads (lb) Vert: 13=-53(1`27, B 27) 14=4(F=2, B=2) 15 1 O(F=-5, B=-5) 16=-35(1`l 7, B l 7) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Mi7ekS connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of indmclual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the to fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSlrrPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institule, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type oty Ply Park Sci HITS/ Sorrento -AorC 2078 T12944466 P2078AC-T KJ7T SPECIAL 1 1 Job Mitl-t-lonaa LUMDer, banow, F L. 6,i:iu s tiep I b s, Inc. t- n jan I Z U /:4bl:Jt1 ZU1 d tage i ID:ItiEL2vqrkv4uEJUYC2jFzkFng-IX7h[FfOyZxKFvmJagATao1 tZJqk2oudbF9XUHzw9oE 1-5-0 3-2-2 64-11 9-10-13 3-2-2 3-2-9 3-6-2 I 4X4 = 3x4 11 Scale = 1:21.4 1§ 3-2-2 6-4-11 9-10-13 3-2-2 3-2-9 3-6-2 Plate Offsets (X,Y)— 2:0-4-3,Edgel, [3:0-0-8,0-2-11 LOADING (psf) SPACING- 2-0-0 cSI. DEFL. in loc) I/defI L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 Tc 0.82 Vert(LL) 0.23 3-8 521 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.92 Vert(CT) 0.47 3-8 253 180 BCLL 0.0 Rep Stress Incr NO WB 0.30 Horz(CT) 0.18 6 n/a n/a BCDL 10.0 Code FBC2017fTPI2014 Matrix -MS Weight: 40 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP DSS TCPCHORD BOTCHORD 2x4 SP No.2 *Except* BOTCHORD 3-9: 2x4 SP No.3, 3-6: 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 5=70/Mechanical, 2=500/0-5-11, 6=367/Mechanical Max Horz 2=142(LC8) Max Uplift 5=-40(LC 8),2 149([_C 8), 6 101(1_c 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 3-4=-1015/253 BOTCHORD 3-8=-312/978, 7-8 313/981 WEBS 4-8=-27/299, 4-7=-1057/337 Structural wood sheathing directly applied or 5-10-6 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=24ft, eave=4ft; Cat. 11; Exp 8; Encl., GCpj=O. 18; MWFRS (directional), Lumber DCL=1.60 plate grip DOL= 1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss Connections. 5) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 40 lb uplift at joint 5, 149 lb uplift at joint 2 and 101 lb uplift at joint 6. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 11 lb up at 1-6-12, 3 lb down and I I lb up at 1-6-12, and 33 lb down and 76 lb up at 7-2-11, and 33 lb down and 76 lb up at 7-2-11 on top chord, and 2 lb up at 1-6-12, 2 lb up at 1-6-12, at 4-4-12, at 4-4-12, and 2 lb down at 7-2-11, and 2 lb down at 7-2-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pin, Vert: 1-3=-60, 3-5=-60, 9-10 20, 3-6=-20 Concentrated Loads (lb) Vert: 14 66(1`33, B=-33) 15=4(F=2, B=2) 17=-2(F=-1, 13 1) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekS conneclors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buciding of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPI1 Quality Criteria, OSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Inforrination available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply Park Sq Hms/ Sorrento-AorC 2078 T12944467 P2078AC-T Mi MONO HIP I Job Reference footiona Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Jan 12 07-49:35 2018 Page I ID:LwgEfgAb9YkKfRKdr2TZXPzS7xJ-IX7hlFfOyZxKFvmJagATaolzOJyc2sjdbFgXUHZW9oE 1-M 3-M 1-8-0 1-4-0 LOADING (psf, SPACING. 2-0-0 CS1. TCLL 20.0 Plate Grip DOL 1.25 TC 0.41 TCDL 10.0 Lumber DOL 1.25 BC 0.41 BCLL 0.0 Rep Stress Incr NO WB 0.06 BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP 3 1.5x4 11 DEFL. in (loc) I/defl L/d Vert(LL) -0.01 6 >999 240 Vert(CT) -0.02 4-6 >999 180 Horz(CT) 0.00 4 n/a n/a LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x6 SP No.2 WEBS 2x4 SP No.3 BOTCHORD REACTIONS. (lb/size) 1=79610-3-8,4=416/Mechanical Max Horz 1 =28(LC 8) Max Uplift 1 1 92(LC 8), 4=-1 1 O(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. VVEBS 2-4=-298/85 Scale = 1:8.7 PLATES GRIP MT20 244/190 Weight: 14 lb FT = 20% Structural wood sheathing directly applied or 3-0-0 oc purlins, except end vertica Is. Rigid ceiling directly applied or 1G-0-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft, L=24ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 192 lb uplift at joint 1 and 110 lb uplift at joint 4. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 7 lb down and 30 lb up at 1-8-0 on top chord, and 982 lb down and 258 lb up at 1-0-12, and 2 lb down at 1-8-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2 60, 2-3=-60, 11-4 20 Concentrated Loads (lb) Vert: 6 982(B) 7=-2(F) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473ret, 1010312015 BEFORE USE. Design valid for use only with MiTekS connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing s always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabncation, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Symbols PLATE LOCATION AND ORIENTATION 14-13/ 4 " Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-16-. t- For 4 x 2 orientation, locate plates 0- 'lid' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate width measured perpendicular4x4toslots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings supports) occur. Icons vary but reaction section indicates joint numberwhere bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPH: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. I `kli ", 11, 3s M2 6-4-8 1 dimensions shown in ft-in-sixteenths I(Drawings not to scale) 1 2 3 TOP CHORDS C1-2 C2-3 WEBS 4 J, 0 M 0 0 0 0- cl, C6-7 0 BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1 311, ESR-1 352, ESR1 988 ER-3907, ESR-2362, ESR-11397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPl 1 section 6.3 These truss designs rely on lumber values established by others. @ 2012 MiTekV All Rights Reserved MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 General Safety NotiI Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSIrrPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSIFrPl 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI I Quality Criteria. zCD C Is No FLOOR AREA FRAMED BY BLDR. FOR HEAD CLEARANCE BELOW. I — 65'- 0" 16 1/2" ZU" - I NOTE: SEE ENGINEERING PROFILES FOR SPECIAL CONNECTIONS AND NAILING SCHEDULES. FLOOR SPACING 24" O.C. UNLESS OTHERWISE NOTED. ALL WALLS SHOWN ARE LOAD BEARING AT 9'-4" UNLESS OTHERWISE NOTED. J L 1 - HUS26 1-PLY HGR I [: 2 - THA422 FLR HGR d L 17 - HHUS46 FLR. HGRS Lu APPROVED TRUSS ANCHOR BY BUILDER BOTTOM =4x2 TOP = 4x2 2x4 Cont. Band 7--\ TRUSS END DETAIL APPROVED TRUSS ANCHOR BY BUILDER PLUMB CUT OVERHANG HEEL HEIGHT = 2 x 4 BOTTOM= 2 x 4 12 TOP= 2x4 6 Pw- V 12 12" TDI ICZ(Z r-:r\lr) r-):TAII MID - FLORIDA LUMBER ACQUISITIONS BARTOW, FLORIDA TRUSS LOADING CONDITIONS ROOF TRUSSES FLOOR TRUSSES 70P CHORD LIVE: 200 TOP CHORD LIOE: 40.0 TOP CHORD OE9D IH TOP CHORD OEAD: 10.0 BOTTOM CHORO DEAD 10,0 BOTTOM CHORD DEHD 5.0 TOTRL LORD IPSF) 40.0 TOTRL LORO IPSF) 55.0 STRESS INCRERSE: 1.25 STRESS INCRERSE 1 rO THIS TRUSS SYSTEM HRS BEEN DESIGNED WITH LORDS GENERRTED BY 140 MPH WINDS USING 4.2 PSF TOP CHORD DERD LORD FIND 30 PSF BOTTOM CHORD DERD LORD 0 MILES FROM HURRICRNE OCEANLINEr CRT. 11, EXF B (RSCE 7-1q) 2078-AorC JPark Square Homes ILEGH- FIDDRISS TRAY CLG. OPT Sorrento - A or C P207BAC is"'N/A 19T'12-171FBmax c b cl) ft"Ill clil cy) u') cl 1kCJ37CJ3 CJ5 C J 5 B6 6/12 B5 6/12 B4 Bl B2 6/12 B3 Cl 6/12 C2 C3 C) CJ5 CJ5 CJ3 CJ3 c LO3 LO cl) cl 1 0 0 25'- 4" 20" NOTE: SEE ENGINEERING PROFILES FOR SPECIAL CONNECTIONS AND NAILING SCHEDULES. FLOOR SPACING 24" O.C. UNLESS OTHERWISE NOTED. ALL WALLS SHOWN ARE LOAD BEARING AT 9'-4" UNLESS OTHERWISE NOTED. CDN c:p J L 2-HUS26 1-PLYHGRS. APPROVED TRUSS ANCHOR BY BUILDER BOTTOM =4x2 TOP = 4x2 2x4 Cont. Band 7--\ TRUSS END DETAIL APPROVED TRUSS ANCHOR BY BUILDER PLUMB CUT OVERHANG HEEL HEIGHT = 2 x 4 BOTTOM= 2 x 4 12 TOP= 2x4 6 W- 1-2 0 12" TRUSS END DETAIL MID - FLORIDA LUMBER ACQUISITIONS BARTOW, FLORIDA TRUSS LOADING CONDITIONS ROOF TRUSSES FLOOR TRUSSES TOP CHORD LIUF: 20,0 TOP CHORD LIUF: 40.0 TOP CHORD OEHO 10,0 TOP CHORD DEAD: 10.0 BOTTOM CHORD DEAD. 10.0 BOTTOM CHORD DEAD: 5.0 TOTAL LORD (PSF) 40.0 TOTAL LORD (PSF) 55.0 STRESS INCREASE: 1.25 ISTRESS INCREASE: Le THIS TRUSS SYSTEM HAS BEEN DESIGNED WITH LORDS GENERATED BY IqO MPH WINDS USING .2 PSF TOP CHORD DEAD LOAD AND 30 PSF BOTTOM CHORD DEAD LOAD 0 MILES FROM HURRICANE OCEANLINE. CRT IL EXP. B (PSEE 7-)4) 2078, - A or C uare Homes Sorrento - A or C F TSJON P2078AC ME 8E, lum-R-7,51 N/A im'J-17 Bmax I RFCORD COPY City of Sanford Building and Fire Prevention Product Approval Specification Form iLD 18- 1,392 Permit # SANFORD Project Location Address a0t k—I As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please -provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal) 1. Exterior Doors Swinging Therma - Tru Single Door FL8871.5 Sliding MI Windows and Doors Series 420 Alum SGD - 2 Panel FL. 15332.4 Sectional Clopay Building Products 94/T40-W4 FL1 5279.20 Roll Up Automatic Other 2. Windows Single Hung MI Windows & Doors Series GA 185 Aluminum SH FL 17499.2 Horizontal Slider Casement Double Hung Fixed MI Windows & Doors Series GA 185 Alum Picture Fixed FL15349.1 Awning Pass Through Projected Mullions MI Windows & Doors 5764 Verical Alum Mullion FL 15353.2 Wind Breaker Dual Action Other June 2014 1 Categoryl Subcategory Manufacturer Product Description Florida Approval # including decimal) 3. Panel Walls Siding James Harding Bldg Products Hardie Panel FI-13223.2 Soffits Aluminum Coils, Inc Coils Soffits FI-12194.1 Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles IKO Industries, LTD Asphalt Shingles Cambridge FI-7006.1 Underlayments Warrior Roofing 15 and *30 Roofing Felt FI-2346.1 Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 2 Category / Subcategory Manufacturer Product Description Florida Approval include decimal) 5. Shutters Accordion Bahama Colonial Roll up Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Ap p I ica nt's N a me Please Print) June 2014 Florida Building Code Online Page I of.3 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search j ieroduCtApprOval USER: Public User Product Approval Menu > Product or Application earch > Application Lis > Application Detail mg FL 4 FL8871-R8 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Therma-Tru Corporation 118 Industrial Drive Edgerton, OH 43517 419) 296-1740 rickw@rwbldgconsultants.com Vivian Wright rickw@rwbldgconsultants.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from -a Florida Registered.Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J. King, P.E. Ti Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL8871 R8 COI (b) Certificate of Independence. od Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 2003 ASTM E1300 1998 ASTM E84 2000 ASTM G26 1995 TAS 201, 202, 203 1994 Florida Licensed Professional Engineer or Architect FL8871 R8 Eauiv (b) Eouivalencv of Standards,pdf http://www.floridabuilding.oror/Pr/Pr_app dtl.aspx?param=wGEVXQwtDqty3 Wak2nHrp... 2/10/2018 Florida Building Code Online Page 2 of 3 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/17/2017 Date Validated 10/17/2017 Date Pending FBC Approval 10/19/2017 Date Approved 12/12/2017 FL # Model, Number or Name Description 8871.1 a. "ClassicCraft Rustic" Series 3'6 x 8'0 "Impact" Opaque Fiberglass Radius Top Single Door (X) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 (b) Inst 8871.1.0 Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.1 for Design Pressure Ratings by L Qi371 118 LE CO—Ev l 8871._I__2df specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 8871.2 b. "ClassicCraft" or "ClassicCraft Rustic" Series 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door (X) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes Laa7l RLL1__(j2)-jnsL85 2.pAf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.2 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871,2.i)df specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. I I 8871.3 c. "ClassicCraft" or "ClassicCraft Rustic" Series 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door with Sidelite (OX or XO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 (b) Inst 8871.3.i)df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.3 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.3,df specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For Fibei-Classic and SmoothStar sidelites, this product approval requires the use of "I" part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871.4 d ' "ClassicCraft" or "ClassicCraft T6 x 8'0 "Impact" Opaque Fiberglass Single Door with Rustic" Series Sidelites (OXO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 (b) inst 8871.4.0f Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.4 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.4.[)df specific Model and for any -other additional use limitations Created by Independent7hird Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of 'T' part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871.5 e. "Fibei-Classic" or "SmoothStar" 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door (X) - Series Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 (b) Inst 8871.5.pdf Approved,for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.5 for Design Pressure Ratings by FL8871 R6 AE (b) Eval 8671.5.1)df specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqty3 Wak2nHrp... 2/10/2018 Florida Building Code Online 18871.6 Pac,e 3 of 3ZD f. "FiberClassic" or "SmoothStar" TO x ST "Impact" Opaque Fiberglass Single Door with Series I Sidelite (OX or XO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ.* Yes FL8871 R8 II (b) Inst 8871.6.1)df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.6 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.6.pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FilberClassic and SmoothStar sidelites, this product approval requires the use of "Y' part numbers for these sidelites, which have been stained or painted within six months of installation.) I8871.7 g, "Fiber -Classic" or "Sm6othStar" TO x 8'0 "Impact" Opaque Fiberglass Single Door withISeriesISidelites (OXO) - Inswing or Outswing I Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 II (b) Inst 8871.7.ndf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.7 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.7.pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of "J" part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871.8 h. "FiberClassic", "SmoothStar", Cl assicCraft" or "ClassicCraft Rustic" Series 60 x 8'0 "Impact" Opaque Fiberglass Double Door (XX) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 11 (b Inst 8871-8.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.8 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.8,cdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. I I 8871.9 L "Fibel-Classic", "SmoothStar", 6'0 x 8'0 "Impact" Opaque Fiberglass Double Door with ClassicCraft" or "ClassicCraft Sidelites (OXXO) - Inswing or Outswing Rustic" Series Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL8871 R8 II (bl Inst 8871.9.Odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.9 for Design Pressure Ratings by FL8871 R8 AE (b) Eval 8871.9.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For Fiber -Classic and SmoothStar sidelites, this product approval requires the use of "Y' part numbers for these sidelites, which have been stained or painted within six months of installation.) F-_- F-7-1 Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-182 The State of Florida is an AA/EEO employer. Copyriaht 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen Jnder Florida-iaw, email addresses are public records. If You do not ant your mail address released in response to a -public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(2), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ON RE E.J Credft Card Sale: http://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wGEVXQNArtDqty3ljWak2nHrp... 2/10/2018 A rl XR SMOOTH STAR & FIBER CLASSIC FIBERGLASS SINGLE DOOR INSWING / OUTSWING jENERAL q0TES "' IMPACT" I . This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane ZoneP(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ" thi S product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the "HVHZ" requiring wind bome debris protection, this product complies with FBC Sections 1409.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level 'V and includes Wind Zone 4 as defined In ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 5. For 2x stud framing construction, anchoring of these units shall be, the same as that shown foe 2x buck masonry construction. 6. Site conditions that deviate from the details of this drcrwIng require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations using coastal sill item #4 under active doors meet water Infiltration requirements for "HVHZ". 8. Inswing configurations and ouitswing cbnfiguratiqns using sill item #5 under the door do not meet the water infiltration requirements for the "HVHZ" and shall be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. TABLE 9F CONTENTS SHEET # DESCRIPTION I I Typical elevations, design pressures & general notes 2 Door panel d etailS r(S mooth star) 3 Door laa-neldetC ils (Fiber CIOSSIc) 4 Horizon-iol-cr-oss —secfions 5 vertical cross sections 6 Buck and frame - 2X buck masonry construction 7 Frame anchoring - I X buck masonry construclion 8 Bill of Materials & Components 11,75'MAI, FRAME WIDTH 11,0(Y'MAX, PANEL WIDTH z PRESSURE. (fS.) DOOR-TY.P. IM ENsION P f N4. F YjEP 'ATIP INSWING 37.75" x 98.00" 80.0 80.0 SMOOTH STAR OUTSWING 37.75" x 96.50" 80,0 80.0 INSWING 37.75" x 98.00" 80.0 80.0 FIBER CLASSIC OUTSWING 37.75" x 96.61Y' 80.0 80.0 See Sheet 8 for design pressure fimitalions. C4 K 19 4110 Er 011 Zon z 0 Z' 2 K oil r 3 6 c 6' a, A Z,a cj A M j Ad i3s DO ir DATE: 0512210 s— N,T.S. DWO. By.. DWS 014K. BY. LFS DRAWING NO.: FL-8871.5 SHEET 01`_. EXTERIOR 0 UU, L—JU-1-1- L DETAIL A -A J 00R IAhffl M.." ., 000000000000000000000000000000000000000000000000000000000001c- 000000000000000000000000000000000000000000000 00000 0-o's00000 0000000000000000000000000000000000000 L000000000000000000000000;2101 DEMIL A -A Panel reinforcement INTERIOR 11— HORIZONTAL CROSS SECTION 1v 4.07-1 TYP. 4 1.53" CORNERS OF PANEL 6 bo 1.53" q no.(Oj 4, 28.86% OPEN AREA MAX . NOTE: WOOD DOOR COMPONENTS: PINE (SG - 0.42) EXTERIOR Al, z Z, 0 r) z 0 0 z z Ma 6 0 (LE3ccn 0 E z INTERIOR ri' VERTICAL CROSS SECTION IV C) V) C, ILI 0 CA 0 DAIF: 05/2Z/O SCALE N.T.S. DwG. BY. ows CHK. BY-. LFS DRAWING NO, FL-8871.5 s"Ev 2 OF 8 A HORIZONTAL CROSS SECTION 4.02" TYP. 4 CORNERS OF PANEL L DETAIL A -A J D00R,.1.ANE1 60 Fiber cFiberclassic 00000000 U12 0000000000000000000000 00000000 000000000000000 1.53" cq 000000 000000000000000000000000000000000000000000000 00000 oo o----ocff 0000000000000000000000 28.86% OPEN 00000000 AREA MAX. 0000000000000000000000 L= - DETAIL A -A Panel reinforcement NOTE: WOOD DOOR COMPONENTS: PINE (SG - 0.42) EXTERIOR INTERIOR d) 6z A, , JO_-- 1 -. t2 z dw 6 1 0 n z N x z z 0 6 Cq & C W 1 0* 5 0 CL E cc VERTICAL CROSS SECTION 0 0 E: N.T.S. BY: Dws Ery: LFS FL-8671.5 0 7 3 OF _2a_ INTERIOR XTERIOR I HORIZONTAL CROSS SkTION Outswing shown - Inswing also approved iki ry *. < a- Z— z 0 Y., 00 c" z C; 0 z 0 z 0 z 6 E 0 Ej c 0 0. Z A SO. Z,0 Q En0En On r Of Of0 DAL* 05122108 SCALE: N. T. S. DWG. BY: DWS HORIZONTAL CROSS SECTION Oviswing shown - inswing also approved EMB. (TYP.) C"X. BY.. LFS DRAMNO NO.: FL-8871.5 sHEEr OF 8 PGf EXTERIOR INTERIOR 1 VERTICAL CROSS SECTION 0 tswing shown - inswing 1suo approved EXTERIOR INTERIOR r4-"\ VERTICAL CROSS SECTION KT) isnSwinegnconligutrationegera0sheet I for "HVHT'water infiltration requirements 4. EXTERIOR INTERIOR VERTICAL CROSS SECTION Shown w1l X sub -buck EXTERIOR INTERIOR t 5 VERTICAL CROSS SECTION k Inswing configuration see general notes, sheet I for "HVHZ" water infiltration requirements z 41: 0 Er z INTERIOR EXTE&/,,,,, inZ om 0 0 nlit z Z* 0 o a. 40 D a, IT Z 'L: 10 L 5 1 oz oA I V C) Z' 0 V) 3 VERTICAL CROSS SECTION CrL W, 0 Outswing configuration see general notes, sheet I 0 for "HVHZ" water infiltration requirements 0 INTERIOR EXTERIOR iE VERTICAL CROSS SECTION Outswing configuration see general notes, sheet I for'IIVHZ" water infiltration requirements DAM: 05122108 SCALE: N. T. S. DWG. BY: DWS CHK. BY: LFS DFZAWTNG NO.: FL-8871.5 SHEET OF 6"' CA d R z e\ A) P\ z a w o on zfillIli, N oTYP. HEAD & E m 2zi A JAMBS N u o cLMASONRYTYP. HEAD & --2 6 OPENING MASONRY JAMBS OPENING Q c E cc A 211 FRAME—/ rq ci fo (.j d 2X BUCK 2XBUCK 5 co o :3nom BUCKANCHORING HINGE JAMB FRAME ANCHORING STRIKE JAMB Masonry 2X buck construction CONCRETE ANCHOR NOTES: I . Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to modarjoints. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortarjoints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: AM I kd*::: AN C H , OR . M . . I .. r , 4 . MIN.:-CLEAPAN.Ct MIN..UEAPAN.CE EMBEDmm 10. MASONRY TO. EDGE:::%:% ANCHOR.::::.:.:. ITW 1/4" 1-1/4" 2" 4" TAPCONO ELCO 114" 1-1/4!' V, 4- ULTRACONO WOOD SCRE INSTALLATION NOTES: 1. Maintain a minimum 518" edge distance, I" end distance, & I" o.c. spacing of wood screws to prevent the splitting of wood. HINGE DETAIL LATCH & DEADBOLT DETAIL DAn: 0512210B SCALE: N.T.S. MG. Ery. DWS CHK. BY: LFS 6ii-kwm -No FL-8871.5 SHEET OF_S E) L 1N n 4': 0 Y% Oz. Z, TJAMBSTYP. HEAD Al fit 011 V) z (5; 6 V 0 nJ & M IIW 0. .. z MASONRY a a Ot C; Q(L OPENING E 1z J/- 0 C in (j C-i Ci ti 0 1 M P FRAME T- 17 iv, R; Q:C) o: r 0 I X BUCK 0 LATCH & DEADBOLT DETA[L I — z 7 L 0 V) INGE JAMB STRIKE JAMB 11 CONCRETE ANCHOR NOTES: FRAME ANCHORING G A 1. Concrete anchor locations at the comers maybe adjusted to maintain the min. Masonry I X buck construction 12 2,R1edgedistancetomortarjoints. MAX. Ix a- 2. Concrete anchor locations noted as ON CENTER" must be adjusted to L maintain the min. edge distance to mortarjoints, additional concrete anchors Mo y be required to ensure the "MAX ON CENTER"dimension are not exceeded. W In3. Concrete anchor table: 12 NMIN -CLEARANCE. MIN CLPAPANCEANCHORDJACENT., TO MASON Y 4—UGG 1240. ITY . . BEDMENTP.E -EDGE::.1, L z 72108 V _:SlZf ITW TAPCON 1/4" 2- 4" HINGE DEWL SCALE, N.T.S. MG. BY: DWSITW TAPCONO 3" CHK, 91: LFS WOOD SCREW INSTALLATION NOTES: 1. Maintain a minimum 518"edge distance, ?-end distance, & l"o.c. spacing of FL-8871.5 wood screws to prevent the splitting of wood. SHEET _7 OF 8 BILL OF MATERIALS ITEM D8CRIPTION MATERIAL A I X BUCK SG - 0.55 WOOD B 2X BUCK SG >= 0.55 WOOD C MAX. I /,VSHIM SPACE WOOD D 1/4" X 2-3/4'PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI301ORHOLLOWBLOCKCONFORMINGTOASTMC90 CONCRETE G 3/16" X 3-1/4'PFH ITW CONCRETE SCREW STEEL J 1/4" X 3-3/4" PFH ITW CONCRETE SCREW STEEL L 10 X 2-1 /Z'PFH WOOD SCREW (1. 15" MIN. EMBEDMENT) STEEL 1 INSWING ADJUSTABLE THRESHOLD (IS300AJ) ALUM.IWOOD 2 INSWING THRESHOLD (IS300HP5) ALUM.1COMP. 3 INSWING SELF ADJUST THERMAL BREAK THRESHOLD (ISP30M) ALUlM./COMP. 4 OUTSWING COASTAL THRESHOLD A LIM. 5 OUTSWING STANDARD THRESHOLD ALUM./WOOD 6 INSWING THRESHOLD ALUM./COMP. 7 DOOR BOTTOM SWEEP VINYL 8 JAMB (PINE) SG >= 0.42 WOOD 9 JAMB (OAK) SG >= 0.42 WOOD 10 WEATHERSTRIP FOAM I I HINGE STEEL 12 10 X 3/4" PFH SCREW STEEL- 13 9 X 3" PFH WOOD SCREW STEEL 14 LATCH STRIKE PLATE STEEL 15 SECURITY STRIKE PLATE STEEL 16 8 X 2-1 /7' PFH SCREW STEEL 17 8 X 3/4" PFH SCREW STEEL 18 KWIKSET SERIES PASSAGE LOCK STEEL 19 KWIKSET SERIES DEADBOLT (660) STEEL 40 SMOOTH STAR DOOR - SEE DOOR PANEL DETAIL SHE FOR DETAILS 41 DOOR SKIN 0.077- THK. (SMOOTH STAR) Fy = 6,000 PSI MIN. FIBERGLASS 42 TOP RAIL (SMOOTH STAR) COMP. 43 LOCK STILE (SMOOTH STAR) WOODAVIL 44 HINGE STILE (SMOOTH STAR) WOOD 45 BOTTOM RAIL (SMOOTH STAR) COMP. 46 PANEL REINFORCEMENT 0.023" THK. JSMOOTH STAR) STEEL 47 FOAM CORE POLYURETHANE 60 FIBER CLASSIC DOOR - SEE DOOR PANEL DETAIL SHEET FOR DETAILS 61 DOOR SKIN 0.1 T7 THK. (FIBER CLASSIC) Fy = 6,000 PSI MIN. FIBERGLASS 62 TOP RAIL (FIBER CLASSIC) COMP. 63 LOCK STILE (FIBER CLASSIC) WOOD/LVL 64 HINGE STILE (FIBER CLASSIC) WOOD 65 BOTTOM RAIL (FIBER CLASSIC) COMP. 66 PANEL REINFORCEMENT 0.023" THK. (FIBER CLASSIC) STEEL U7 FOAM CORE P51-YURETHANE 4.56' 3,(j>HEAD & SIDE 8 '. " Jamb 5.72" THRESHOLD Insveing adjustable 5.87' zo r."\ THRESHOLD Inswing self -adjust 5.75" US Oufsvving standard L — 5.85, f4t—M qp r RESHOLHInsMng —adjDustable 4.57' THRESHOLD k,:,) outswing coastal THRESHOLD lnsMng MAX. DESIGN PRESSURE 1/- 50 PSF] 6z v 0- 0 0 w 6 0 1) z 8 0 0 x I z o z o 6 cc w 00 c .0 n 0. IL C 0Oz K: c' lla 00 V) w CL M 0 68 0 tL- 02IR N DATE: 05122108 SCALE: N.T.S. M. BY: DWS CHX. ery: LFS DRAMNG NO, FL-8871.5 Ic Florida Buildinc, Code Online Page 1 of 6t=, OF TIN R401-g- WON1110- J,2017' OR& 560 BCIS Home Log In User Registration Hot Topics 5 Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search gg Product Approval w§1USER: Public Userpr Product Approval Menu > Product or ADolication Search > Application Lis > Application Detail 5MIT FL # FL15279-R521-'-R l Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated reapply 11/28/17 Clopay Building Products Company 8585 Duke Blvd. Mason, OH 45040 513) 770-6062 mwesterfield@clopay.com Scott Hamilton shamilton@clopay.com Exterior Doors Sectional Exterior Door Assemblies Certification Mark or Listing Intertek Testing Services NA, Inc. Gary Pfuehler R Validation Checklist - Hardcopy Received. Standard ANSI/DASMA 108 ANSI/DASMA 115 ASTM E1886 ASTM E1996 ASTM E330 Year 2005 2005 2002 2002 2002 Florida Licensed Professional Engineer or Architect FL15279 R5 Eauiv 20170809 - FBC - DASMA 108 eouiv.od FL15279 R5 Equiv 20170809 - FBC - DASMA 115 ecuiv.pd Method I Option A 08/10/2017 11/29/2017 https:Hwww.floridabuilding.orc,lprlpr—app_dtl.aspx?param=wGEVXQwtDqv:')yVVKJZIQ... 2/1/2018 Florida Building Code Online Page 2 of 6 Date Pending FBC Approval Date Approved 12/05/2017 Summary of Products Go to Page dn 0 0 Page 1 / 8 Q 0 FL # Model, Number or Name Description 15279.1 001 W3-09 DSIE-1A171: 2050, 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; 2051,2053,4050,4051,4053, 62, interior skin 29 ga. min.) Single -Car (up to 9'0" wide) 64, 65, 62G, 62LG, 64G, SDP38, WINDCODE@ W3 Garage Door SFL38, SRP38, 134, 135, 136, 16130,6131,6133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of inspectionjDdAprprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W3 1-151in Interte k.df Design Pressure: +20 PSF/-20 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 11 101655-Revl2.pd windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.2 002 W3-09 DSIE-lA471: GD1SP, Gallery/Artistry/Expressions: 1-3/8" Double -skin Insulated GR1SP, GD1LP, GR1LP, AR1SP, EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) ARILP, ED1SP, ED11-P, 4132, 2132, Single -Car (up to 9'0" wide) WINDCODECD W3 Garage Door 6132, SFC36, MFC38 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of insoection.pciApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W3 Listing IDtertek.gg!f Design Pressure: +20 PSF/-21 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 II 103952-Rev0l.i)d windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.3 003 W3-09 DSIU-1A171: 9130, Double -skin Insulated PUR (exterior skin 27 ga. min.; 9131, 9133, HDP13, HDPF13, interior skin 27 ga. min.) Single -Car (up to 9'0" wide) HDPL13, 7130, 7131, 7133, 8130, WINDCODE@ W3 Garage Door 8131, 8133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 RS C CAC Letter with proof of contract and proof of insQection.pdApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W3 Listing Intertek.lpdf Design Pressure: +20 PSF/-20 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for 29 R5 II_104175-_Rev0l_pdfEL152 windborne debris regions. The product without glazing DOES Verified By: Inter -Lek Testing Services NA, Inc. comply with the impact resistant requirement for windbornii Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.4 004 W3-16 DSIE-1A171: 2050, 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; 2051,2053,4050,4051,4053, 62, interior skin 29 ga. min.) Double -Car (9'2" to 16'0" wide) 64, 65, 62G, 62LG, 64G, SDP38, WINDCODE@ W3 Garage Door SFL38, SRP38, 134, 135, 136, 6130,6131,6133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of inspection,ndApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W3 ListincLlntertek._pdf Design Pressure: +20 PSF/-21 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the.wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 P,5 II 101820-Revl3,pd windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.5 1 https://www.floridabuildino,.org/pr/,nr app dtI.aspx?parani=wGEVXQwtDqv3yVVK IQ... 2/1/2018JZ Florida Building Code Online Page 3) of 6 005 W3-16 DSIE-lA471: GD1SP, GR1SP, GDILP, GP,1LP, AR1SP, AR1LP, ED1SP, EDILP, 4132, 2132, 6132, SFC38, MFC38 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Gallery/Artistry/Expressions: 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double -Car (9'2" up to 16'0" wide) WINDCODEO W3 Garage Door Certification Agency Certificate F1 15279 R5 C CAC Letter with proof of contract and proof of inspection.iDd FL15279 R5 C CAC W3 Listing Intertek.od Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 11 104028-Rev0l.i)d Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.6 006 W3-16 DSIU-1A171: 9130, Doulble-skin Insulated PUR (exterior skin 27 ga. min.; 9131, 9133, HDP13, HDPF1 3 i nteno r skin 27 ga. min.) Double -Car (9'2" to 16'0" wide) HDPL13, 7130, 7131, 7133, L30, WINDCODE@ W3 Garage Door 8131, 8133 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate EL15279 R5 CAC Letter with Qroof of contract and oroof of inspection.pd FL15279 R5 C CAC W3 Listing Intertek.pd Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 RS II 104168-Rev0l.()d Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.7 007 W3-16 PAN-21`153: 73, 1500, Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) 75, 190, 84A, 94, 42, 48, S5, 42B, WINDCODE@ W3 Garage Door 48B, 55S, 4PST, 6RST, 4RSF, 6PSF Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 R5 C CAC Letter with [)roof of contract and proo of inspection.pd FL15279 R5 C CAC W3 Listing Intertek.od Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 11 101308-Revl2.1)d Verified By: Intertek Testing, Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.8 008 W4-09 DSIE-11`171: 4300, 2" Double -skin Insulated EPS (exterior skin 27 ga. min.; 4301, 4310, 4400, 4401, HOG, interior skin 27 ga. min.) Single -Car (up to 9'0" wide) HDGL, HDGF, 66, 66G, 67, 67G, WINDCODE@ W4 Garage Door 68, SP200, SF200, SE200, 6200, 6201,6203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure. +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building, code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DO -ES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate E_Lj_7 j R5 C CAC Lettg r vLitL_pLoqf of c ontrq2 1.nd proo of inspection.od I FL15279 R5 C CAC W4 Listing Intertek-nd Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 II 101652-B-Revll,pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.9 009 W4-09 DSIE-11`471: GD2SP, Gallery/Artistry/Expressions: 2" Double -skin Insulated EPS GR2SP, GD2LP, GP.2LP, AR2SP, (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single- AR2LP, ED2SP, ED2LP, 4302, Car (up to 9'0" wide) WINDCODE@ W4 Garage Door HDGC, 6202, SK68, MFC68 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with Droof of contract and proof Approved for use outside HVHZ: Yes of inspection.od Impact Resistant: No FL15279 R5 C CAC W4 Listing Intertek.i)d Design Pressure: +28 PSF/-29 PSF Quality Assurance Contract Expiration Date Other: The standard glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions FL15279 R5 II 103969-B-Rev02.pc1 https://www.flon*dabuilding.org/pr/pr-app_dtl.aspx?param=wGEVXQwtDqv')yVVKJZIQ... 2/1/2018 Florida Building Code 0nlM'eC Page 4 of 6 DOES NOT meet the impact resistant requirement for Verified By: Intertek Testing Services NA, Inc. windborne debris regions. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.10 010 W4-09 DSIU-11`171; 9200, Double -skin Insulated PUR (exterior skin 27 ga. min.; 9201, 9203, HDP20, HDPF20, interior skin 27 ga. min.) Single -Car (up to 9'0" wide) HDPL20, 7200, 7201, 7203, 8200, WINDCODE@ W4 Garage Door 8201,8203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.11 011 W4_09 DSIUO-11<479: CanyonIRidge/Brookstone Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this pr oduct meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.12 012 W4-09 PAN-21`151: 73, 1500, 75, 190, 84A, 94, 76, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 6RSF, 2RST, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. 15279.13 013 W4-09 PAN-21`441: G4S, GS4, G4L, GL4, GD4S, GD4L, GR4S, GR4L, G4SV, GS4V, G4LV, GL4V, GD4SV, GD4LV, GR4SV, GR4LV, E4S, E4L, ED4S, ED4L, E4SV, E4LV, ED4SV, ED4LV, SS4, SL4, AR4S, AR4L, SS4V, SL4V, ARASV, AR4LV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. Certification Agency Certificate FLIS279 R5 C CAC Letter with proof of contract and proof of inspection.1)d E_LL5 279 R5 (LCAC W4 _ListLirL Injcrtqj S. q__ _!_ _Af Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLIS279 R5 11 104183-RevOl.c)d Verified By: Intertek Testing -Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Double Skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Single -Car (up to 9'0" wide) WINDCODE@ W4 Garage Door Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proof of inspection.pd . FLIS279 R5 C CAC W4 Listino Intertek,pd Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 11 104456-RevOl.r)d Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) WINDCODE@ W4 Garage Door Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proo of ins ec i n. df FL15279 R5 C CAC W4 Listin6 Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 II 300159-B-Revl6.pd Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Single - Car (up to 9'0" wide) WINDCODE@ W4 Garage Door Certification Agency Certificate FL15279 R5 C CAC Letter with proof of contract and proo of inspection.pd FL15279 R5 C CAC W4 Listing Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 II 103486-B-RevO8.pd Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.14 014 W4-09 SPO-21`449: Grand Steel Pan (min. 24 ga.) with Overlay Single -Car (up to Harbor, Stone Manor 9'0"wide) WINDCODE@ W4 Garage Door https://www.floridabuilding.org/pr/r)r-app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1Q... 2/1/2018 Florida Building Code Online Pac,e 5 of 6 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-32 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate FL15279 R5 C CAC Letter with Droof of contract and proo of inspection.pd FL15279 R5 C CAC W4 Listing Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R5 Il 103549-RevO6.cd Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Repo ' rts Created by Independent Third Party: 15279.15 015 W4-16 DSIE-11`171: 4300, 4301, 4310, 4400, 4401, HOG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201,6203 2" Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double -Car (9'2" to 16'0" wide) WINDCODE@ W4 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with roof of contract and prqof of-inspection.pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL15279 R5 C CAC W4 Listing Intertek.odf Design Pressure: +25.5 PSF/-25.5 PSF Quality Assurance Contract Expiration Date Other: The standard glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FLlS279 P,5 II 101481-B-Revl1cid mindborne debris regions. Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.16 016 W4 16 DSIE-11`471: GD2SP, Gal lery/Artistry/Expressions: 2" Doubie-skin Insulated EPS GP,2SP, GD2LP, GR2LP, AP,2SP, exterior skin 27 ga. min.; interior skin 27 ga. min.) Double- A 21_P, ED2SP, ED21_P, 4302, Car (9'2" up to 16'0" wide) WINDCODE@ W4 Garage Door HDGC, 6202, SFC68, MFC68 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with pjoof of cqnti-E t and pLojpf of inspection.1)dApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL15279 R5 C CAC W4 Listing Intertek.1)df Design Pressure: +25.5 PSF/-25.5 PSF Quality Assurance Contract Expiration Date Other: The standard glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 II 104029-6-RevO3.pdf windborne debris regions. Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.17 017 W4-16 DSIEO-11`479: Double Skin Insulated EPS (exterior skin 27 ga. min.; Coachman/Settlers/Affinity interior skin 27ga. min.) with Overlay Double7Car (up to 16'0" wide) WINDCODE@ W4 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proo Lf inspeqtio0_pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 R5 C CAC W4 Listing Intertek.cid Design Pressure: +25 PSF/-25 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 II 103046-RevO7.pd windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.18 018 W4 16 DSIU-1F171: 9200, Double -skin Insulated PUR (exterior skin 27 ga. min.; 9201, 9203, HDP20, HDPF20, interior skin 27 ga. min.) Double -Car (9'2" to 16'0" wide) HDPL20, 7200, 7201, 7203, 8200, WINDCODE@ W4 Garage Door 8201,8203 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter , with proof of contract and iproof j2f ins-pe(Ltion p fApprovedforuseoutsideHVHZ: Yes,, Impact Resistant: N/A FL15279 R5 C CAC W4 Listing Intertek.r)df Design Pressure: +25.5 PSF/-25.5 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 II 104169-Rev0l.[)df windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: https://vAvw.florldabuilding.org/pr' r a -on dtl.aspx?param=wGEVXQwtDqvDyVVKJZIQ... 2/1/2018P_ Florida Building Code Online Page 6 of 6 15279.19 1019 W4-16 DSIUO-1K479: Canyon Double Skin Insulated PUR (exterior skin 27 ga. min.; Ridge/Brookstone interior skin 27ga. min.) with Overlay Double -Car (9'2" to116'0" wide) WINDCODE@ W4 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proo of nsDectlon.DdApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL15279 P,5 C CAC W4 Listing Intertek.adf Design Pressure, +25.5 PSF/-25.5 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 R5 II 104457-RevO2.1)d windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.20 020 W4-16 PAN-2FI53: 73, 1500, Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) 75, 190, 84A, 94, 42, 48, 55, WINDCODE@-W4 Garage Door 4RST,6RST,4RSF,6RSF,GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV,ED5S,ED5SV Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLlS279 R5 C CAC Letter with proof of contract and proo of inspection. OdApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL15279 R5 C CAC W4 Listing Intertek.pd Design Pressure: +24 PSF/-24.5 PSF Quality Assurance Contract Expiration Date Other: The standard glazing available for this product OS/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279r R5 11 101711-B-Revl5.lpdf windborne debris regions. Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Go to Page = it F - 1:71 F7__ 1 0 Page 1 / 8 0 0 Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phore 850-487-182 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487. 1395. -Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The ennalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: C-ed.'l C&d, Safe. https://www.floridabuildinc,.oro,/pr/pr app dtl.aspx?param=wGEVXQ-,NqDqv3yVVKJZIQ... 2/1/2018 UMAGE HWSE' RA SO PA S VwRs NOD S Irs M m CLOPAY GD13. V. 6411.ay' ms GRSSV MESMTISTR" 2 1 R,Sv IDEA. CKRR HIXISE' 3 EV3SV 11" 0= 71 11 FW__ DOM wom 11 ] 1.1 11 DATE DESCRIPTION I SHEET 1 OF 2 DED EXTENDED HSCHTS, COMBINil) CLOPAY, HOLMES, AND IDEAL A RJ11111 i'll 11"' 071 Ifim""M 1 71m A:= rl W) ' OPTIONAL GLAZING MAY BE STANDARD OR IMPACT RESISTANT GLAZING. SEE SECTION B-B FOR DETAILS. MAX. STANDARD SIZE 13 42-1/2"06'. IMPACT RESISTANT GLAZING IS 21-5/8%14-1/8". mi DPT*tAL VWM RNSO- "' ' 'mSS' Rh,SED-pma m mw h-PRIVO. 114./t, swuEIN. Scf&vS -,\- a yy A v mm'n camm 3 SHIP UP JOINT'S. - A m I=m pa SEE SHEET TWO FOR IMPACT RESISTANT CONSTRUCTION DETAIL "A" AND STANDARD CONSTRUCT DETAIL "B",- TRACK AND JAM13 D&AILS. DESIGN ENGINEER: rK WESTERFIELD. P.E.1FLORIDAP.E. #484 NO P.E. 12-32, TEXAS P.E. jqI513 If DENSrrY POLYSTYRENE FOAM INSULATION 1-5/16- THICK WITH VINYL HAIRCELL BACKER (INSULATED MODELS ONLY) 25 GA. MIN. GALV. STEEL SKIN WrTH A BAKED -ON PRIMER, AND A BAKED -ON POLYESTER TOP COAT APPLIED TO BOTH SIDES OF STEEL SKIN. W. 2) cmR w v w m ZWL 3) 4) w A Rw= M—M S. j.. .1 B. c I I IV MPC: PAN-2FalepayDATU1/3/97 5 D IKE BLVD Building Products 'M5ABON LOH 450 :jb DRAWN BY, JAC Company (513) Ii70-48DO — THECKED BY, Cl.p.y ',T-U.. AS Right. R—d. mWW PPROVAL 15279 ADDED MIN 4F FOR ASCE7-10. 3 - TALL. U-BAR SECTION A -A (SIDE ME)Yj_ 20 GA. GALV. STEEL MIN. YEILD STRENGTH: 50 KSI 2' THICK T 12 GA. GALV. STEEL TOP ROLLER BRACKET. EACH BRACKET ATTACHED W/(4) 14x5/8" SHEET METAL SCREWS. 14 GA. CALV. ROLLER HINGE. EACH HINGE FASTENED TO END SnLES WITH (4) # l4x5/8- SHEET METAL SCREWS AND (4) 1/4 ' x3/4' SELF TAPPING SCREWS. SEE MEW W. 3 11 3" TALL x 20 GA. GALV. STEEL U-BARS IN A 2-1-2-1 PATTERN (I.E. TWO U-BARS ON BOTTOM SECTION. ONE U-BAR ON NEXT 3 SECTION. ETC.;" EACH U-BAR ATTACHED WITH (2) 1/4 /4" SELF TAPPING SCREWS PER snLE LOCATION. 13 GA. GALV. STEEL BOTTOM BRACKET. ATTACHED WITH (2) #14x5/8' SHEET METAL SCREWS. ALUMINUM EXTRUSION VINYL WEATHERSTRIP. DESIGN LOADS: +24.0 PSF & -24.5 PSF TEST LOADS: +36.0 PSF & -37.0 PSF MAX. DOOR 11 E, 4 16'0"W x 16'O*H DESCRIPT104 CLASSIC AND CH RP STEEL PAN DOUBLE -CAR, WIN +24/-24.5 PSF B1DRAWIMW UMDER- 101711 11113C mass DOORS msl es GA I TARRLAGE HOUSE, RAMM PANEL MOMELS 25 GA 10 GA MIS Gmemy, CLOPAYGALLERY' GR3Sv 3 ARTISTRY' AR'S 5SAN V 13 s I 051VCANsammmu.Isv am MONT IS -I-- I IF wilSECTIONS UP, -vTO 4 1 6 1 3/a-.3- LAS SGREWS ON 2144"W CENTERS, 1-1/8- O.D. WASHER REOLINED. W 77 Fv- a 8 G 9 SCREWS MAY BE CM44MUNK (BW NOT REOU TO P DE A FUDIHMCKINTINOSACLHORIZONTALJANUSDoNOMSFERLOAD. 0`91 TO lew 7 u Z6' TO 14T' 4- TO Wr 9 2 9 14 GRU E MmL.WwWEM="H—' ( 2A.W M UK 1610, 10 15' OR MAX SECTT. — gL- 114-a- TAPCON SCREWS ON 17. CENTERS (2.000 PSI US. CDNOWtE) OR D* GENTERS I— ), V 0 D. RM— WON TAPMRS. ANCHORS MAY BE C"DUMM MY NOT REQU=PSKIME A nlISH MOUNTING SURFACE HORIZONT& M 00 NOT Lm. REFER TO DASUA TDS-101. A LICENSED DESION MI — ALTENNATE Ame/m mNa —Txm. sTre mot,tLoma BY WON m7mlER CTO Sun GA. MIN. DALY. STES. END STILE 2a YELLOW PINE 20 20 GA. WV STEEL WER. STILE - IMPACT RESISTANT ASSEMBLY DETAILS DRAWING 1017 _A 5ECTION B-B (IMPACT -RESISTANT GLAZING OPTION D"ODN". DODORIDW W&`P"`NPDB` HKO DOND TAPEI ZLM— AND M-Im. j- KIDDKE SEVOCEN SMEE. SUN AND IFRAME). ONE PDL a LEIAN (10) IS 3/4'M HEAD MADNIE 3— V-43 IMONT E.— DDGNS WITIT ONAIL 0 AREIMPAWOWN. D=- INJECTION -MOLDED POLYCARSONAME FRONT FRIJAE AND NG M GE LEQNN SLX2,VIU. AN APPRONED CCa IN X Q E WON RMR ASSEMBLY INSTALLED IN WON TM SECTION MEETS ME WIND LOAD REOMEMENTS V ME FLORIDA MUM CODE AND INTERNATIONAL BULDIND ODDE &M U= ME IWPACr-RESISTANT REQUIREMENTS (REF. CHAPTER 18 FBC/IBC). S= ASSEM13LY DETAILS NG 10171 1 -El SECTION B-9 (NON -IMPACT RESISTANT INONT FRAME Wall ON. COATING ON OUTSIDE SURFACE NOTE T FRANE IS NAARGWER THAN NPACT RESISlAINT FRAME. MOLDEDLITERETAINER- 18.3/4' PAN H EW. MMY CONSTRUCTION I'VV ACYRUC UTES AVAILABLEISPWVOUTEOPTDCRLUCRE PfWED IN ACCORDANCE WITH ISC/M 2M. DIE UNION DOOR ASSENERY INSTALLED IN COMPLIANCE WON TH SECTION MEETS THE WIND LOAD REQUIRDENTS OF ME FLERM'LBn No ODEE OR *MENNAT"M BUILDING WDE BUY ff WEEY ME WAGY RESISTANT no REU NOBORNE DEBRIS REDKINS W. MAPTER 16 FOC/10C). SHEET 2 OF 2 WON ONE FASTENED 18 G& OALV. RINGS. EAN PER BRACKET. --I— NME FASTENED m ROUND P,%MT ONE PER ROLLER) 2 GAIJV. STEEL. T K FASTENED TO 14 GA. DAILY. ROLLER — EAGN 20A.DALV 00 STILES. WITH (4) F /. NOTE' TRAC CONFIGURATION X&C ".2/11 "415 6 SHEET MAL SCREWS AND (4) A13OVE THEKDOOR OPENING Oft TWO 1/4- 4-.3/4- StlF TAPPINIG DOES NOT AFFECT THE VIIND LOAD RATING OF THIS DOOR. 2' 10 SAUL SHORT STEIN SMM ROLLER WON STEEL OR NYLON TIRE HORNIDWAL TRACK SUPPORt BY DR INSTALLER TO SUM) jjWTAU. D6ORS AND UNDER R TOP BRACKET N=- ME DESKIN M THE RIPPORTING SMUCTURAL EUEWENTS SKILL SE ME GA. G012V STEEL nAQ BRACXLT RESPVCSIBI OF THE PROFESSIONAL OF REGORD FOR ME BUILOM OR I FASTENED M WDDO JAVI WON DOUBLE HORIZONTAL STINXTURE AND IN AmDR WITH CLIRRENT BLALDSNO CODES, nxt ME LOADS, (3) Spr.i-a/a- Waco LAG —Ews, bE TRACK LISTED ON ME DRANM. 1HEDOTITLI:j OOM 0 ON 2" MV. STEEL TRACK 17 W TRACK XN114I: t/2 GALV STEEL BRACKET 4) PER SIDE. L HOR120"T'L a7r DOORS WER W TALL lug 13 Gk (00. STEEL FLAG BRACKET, EACH F TO WOOD B WITH Fm 3) S/ LAG DESIGN ENGINEER: MARK WESTERFIELD, RE FLORIDA P.E. j4a4Q5. NO P. E 111 231132, TEXAS .E. #91513 FLOO MDA PRODUCT ffe WE. PAN--VF16-j ulepay DATE. 1/3/97 Ilding Products 8585 DUKE BLVD. DRAWN BY. MASON, OH 45040 JAC mpa (513) 770-4800 CHECKED BY, Cl.p.y C.rp—tl- All Right. Ft"—d. Mww V&D )If-q,9)70 NOM FOR DOORS OYER E 12'-0' NGN, TWX CONFIGU ON SKILL NOT EXCEED MAXIMUM SPACING PROVIDED. CONSUILT FACTORY FOR MOM DUAL ROD DESIGN LOADS: +24.0 PSF & -24.5 PSF TEST LOADS: +36.0 PSF & -37.0 PSF VD4111-1111 WEND I MAY IDER SIZE W4 16'0-W x 16'0"H DESCRIPTION, CLASSIC AND CH RP STE DOUBLE -CAR, 16V +24 F—ER. 101711 Florida Buildinc, Code OnlineD Page I of 4 BCIS Home Log In User Registration I Hot 7opics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Vvill"flN, Product Approval A" 'USER: Public UserdbON Product Approval Menu > Product or Aoolication Search > Application Lis > Applicatiort Detail FL17499-R3FL # Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard AAMA 506 AAMA/WDMA/CSA 101/I.S.2/A440 AAMA/WDMA/CSA 101/l.S.2/A440 Equivalence of Product Standards Certified By Product Approval Method Method I Option A Date Submitted 01/15/2018 Date Validated 01/15/2018 Date Pending FBC Approval Date Approved 01/21/2018 Yea r 2011 2008 2011 https://www.floridabuilding.oro,/pr/pr app dtl.aspx?parain=wGEVXQA4DqtCUGgvjQiz6B... 2/1/2018 I Flon'da Building Code Online Page 2 of 44:1 Summary of Products FL # Model, Number or Name Description 17499.1 185 SH 36x84 Fin/Flange Frame IG/SG Impact Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 P,3 C CAC MI Windows - 18S SH (Fin) Imipac 4)-odApprovedforuseoutsideHVHZ: Yes Impact Resistant: Yes FLI 7499 R3 C CAC MY Windows - 185 SH (Fin) Imr)act (5) Done.l)dDesignPressure: +55/-55 Other: R-PG55*, Missile Level D, Wind Zone 3. Glass to be FL17499 R3 C CAC MI Windows - 185 SH (Flange) Impact U DjffbeddedinPecora896sealant. FL17499 PQ C CAC MI Windows - 185 SH (Flange) Imt)act 4)-od Quality Assurance Contract Expiration Date 10/17/2018 Installation Instructions FL17499 R3 II 08-02545B.i)d Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513321B-3,j)ff Created by Independent Third Party: Yes 17499.2 185 SH 52x72 Fin/Flange Frame IG/SG Single Hung Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC APC(13361)El726.01-109-47-RO 185 SH(FLG waiver).[)dfApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL17499 R3 C CAC MI Windows - 185 SH (Fin) (11).od FL17499 R3 C CAC MI Windows - 165 SH (Fin) (12).DdDesignPressure: +60/-60 FL17499 R3 C CAC MI Windows - 185 SH (Flange) Other: R-PG60 10).Pdf Quality Assurance Contract Expiration Date 10/08/2018 Installation Instructions FL17499 R3 II 08-02549B pdf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513327B-4.pd Created by Independent Third Party: Yes 17499.3 185 SH 36x84 Fin/Flange Frame IG/SG Single Hung Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC APC(13363)El729.01-109-47-RO 165 SH (FLG waiver).odfApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL17499 R3 C CAC MI Windo vs - 185 SH (Fin) (13).Dd FL17499 R3 C CAC MI Windows - 185 SH Fin) (14).r)dfDesignPressure: +60/-60 FL17499 R3 C CAC MI Windows - 185 SH (Flange) Other: R-PG60* 11).pd Quality Assurance Contract Expiration Date 10/17/2018 Installation Instructions FL17499 R3 11 08-02550B.r)d Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513328B-5.i)d Created by Independent Third Party: Yes 17499.4 1185 SH 36x7i Fin, Finless, Flange Frame IG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ. No FL17499 R3 C CAC APC H0462.01-109-47-RO 185 SH 042522).t)dApprovedforuseoutsideHVHZ, Yes Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +60/-67 04/25/2022 Other: R-PG60* Installation Instructions FL17499 R3 11 08-03163.od Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 514082.lpd Created by Independent Third Party: Yes 17499.5 52x72 Fin/Flange Frame IG/SG Impact Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC MI Windows - 185 SH (Fin) Impact 2). pdApprovedforuseoutsideHVHZ: Yes Impact Resistant: Yes FL17499 R3 C CAC MI Windows - 185 SH (Fin) Imoact https://www.floridabuilding.org/p-r/T,)r_app_dtl.aspx?param=wGEVXQvADqtCUGgvjQiz6B... 2/1/2018 Florida Building Code Online Page 3 of 4 Design Pressure: +55/-55 3).Dd Other: R-PG55, Missile Level D, Wind Zone 3. Glass to be FL17499 R3 C CAC MI Windows - 185 SH (Flange) Impac 2). odbeddedinPecora896sealant. FL17499 R3 C CAC MI Windows - 185 SH (Flange) ImQac 5).r)d Quality Assurance Contract Expiration Date 10/10/2018 Installation Instructions FL17499 R3 II 08-02544B-I.r)df Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 5!332OB-1.1)df Created by Independent Third Party: Yes 18517499.6 SH 52x84 Fin/Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved fcyr use in HVHZ: No FL17499 R3 C CAC APC(13362)EI725.01-109-47-RO 185 SH(FLG waiver)5-8IG 1-8A 52 1-8X84 R60(100918).r)dfApprovedforuseoutsideHVHZ: Yes i)dfImpactResistant: No FL17499 R3 C CAC MI Windows - 185 SH (Fin) (9).Qdf - Design Pressure: +60/-60 FL17499 R3 C CAC MI Windows - 18S SH (Flange) (9).pdfOther:R-PG60 Quality Assurance Contract Expiration Date 10/09/2018 Installation Instructions FL17499 R3 II 08-02546B-2.1)d Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL17429 R3 AE 513 22LE2.Ldf Created by Independent Third Party: Yes 17499.7 185 Triple SH 111x72 Fin Frame IG/SG Single Hung 110x72 Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC MI Windows - 185 SH Triple (Fin) 3), odApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL17499 R3 C CAC MI Windows - 185 SH Triple (Fin) 4) - QdDesignPressure: +50/-50 Other: R-PG50* FL17499 R3 C CAC MI Windows - 185 SH Triple (Flanae) 3). Dd FL17499 R3 C CAC MI Windows - 185 SH Trii)le (Flanoe) 4). I)d Quality Assurance Contract Expiration Date 10/20/2018 Installation Instructions FL17499 R3 II 08-02548Bpff Verified By: Luis R Lomas PE 62514 Created by independent Third P Arty: Yes Evaluation Reports FL17499 R3 AE 513324B-6.r)df Created by Independent Third Party: Yes 17499.6 185 Twin SH 106x72 Fin Frame IG/SG Single Hung 105x72 Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C CAC MI Windows - 185 SH Twin (Fin) 3). DdApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL17499 R3 C CAC MI Windows - 185 SH Twin (Fin) 4) - pdDesignPressure: +45/-45 Other: R-PG45 FL17499 R3 C CAC MI Windows - 185 SH Twin (Flange 3).od FL17499 R3 C CAC MI Windows - 185 SH Twin (Flange) L4)__pAf Quality Assurance Contract Expiration Date 10/20/2018 Installation Instructions FL17499 Ra I1_2 L-_025476-7pdf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R3 AE 513323B-7.1)d Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-182 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen https://www.floridabuilding.orc,/pr/pr app dtl.aspx?param=wGEVXQNN4DqtCUGgvjQiz6B... 2/1/2018 Ia Building Code Online Page 4 of 4 Under Florida Ia., email addresses are public records. If you do not want your e-maii address released in response to a public -records request, do not send electro hic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you am a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Ez Credit Card Safe I https://www.floridabuildinc,.org/pr/pr app dtl.aspx?param=wGEVXQvADqtCUGgvjQlz6B... 2/1/2018 NOTES: I . THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASON RY/CO NCR ETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS 15 LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE IX BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 11 FOR CLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. REVISIONS DESCRIPTION -PROVED REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L. REVISED GLASS 10/02/17 R.L. 15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16'. TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT. 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF C=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,OOOPSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063—T5 FU=30KSI .048" THICK MINIMUM I TABLE OF CONTENTS I SHEET NO. I DESCRIPTION I I NOTES 2 3 ELEVATIONS 4 10 INSTALLATION DETAILS 11 1 COMPONENTS SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET I '\ C, N E NGRATZ, PA 17030-0370 S' .."p -r, zsSERIES185ALUMINUMSINGLEHUNGWINDOW 52" X 72" NON —IMPACT NOTES I OF Z R. DRAWN: DWG NO. REV N.G. 08-02549 B X 1111\0 Luis R. Lomas P. E. FL No.: 62514 SCALE NTS J'AT' 12/29/147T j OF 11 I. ROBERTO LOMAS RE 1432 WOODFORD RD LEWISVILLE, NO 27023 434-688-0609 rilomasoirlomaspe— 52" MAX FRAME WIDTH 2" MAX 16 MAX D.C. rA2L- 16" MAX D.C. 12 T_ IAX AME IGHT 2" X 52" MAX FRAME WIDTH 2" MAX 2" M AX 16" MAX O.C. 2" MAX 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW FLANGE& FINLESS INSTALLATION SEE CHART #1 FOR SMALLER UNITS REQUIRED ANCHORS 2" 16" MAX on D.C. 72" MAX FRAME HEIGHT 185 ALUMINUM SINGLE HUNG Wlp rr n,11 REVISIONS DESCRIPTION DATE AP ROVED REVISED ANCHOR SPACING & CHARTS D7/1 1/15 R.L. REVISED GLASS 10/02/17 R.L. CHART#I Number of anchor locations required Frame Frame Width (in) Height 19.00 24.00 30.00 42.00 48.00 52.00 in) Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb 24.00 2 3 3 3 3 3 3 3 4 3 4 3 4 3 30.00 2 3 3 3 3 3 3 3 4 3 4 3 4 3 36.00 1 2 3 3 3 3 3 3 3 4 3 4 3 4 3 42.00 2 4 3 4 3 4 3 4 4 4 4 4 4 4 1 48.00 2 4 3 4 3 4 3 4 4 4 4 4 4 4 54.00 3 5 3 5 4 5 5 4 5 60.00 2 5 3 1 5 3 1 5 5 4 4 5 4 5 66.00 2 5 3 1 5 3 1 5 3 5 4 5 4 1 5 4 5 72.00 2 1, 3 1 6 1 3 1 6 3 6 1 4 6 4 1 6 4 1 6 DESIGNER EXTERIOR VIEW FLANGE& FINLESS INSTALLATION SEE CHART #1 FOR SMALLER UNITS REQUIRED ANCHORS DESIGN PRESSURE RATING IMPACTRATING 60.OPSF NONE SIGNED: 1211412017 NOTES: 1. MAXIMUM SASH SIZE: 51" X 35". MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 R L 0a 41 N'Y'..'p .5. 2. MAXIMUM SASH D.L.O.: 47 5/8" X 32 1/2". 3. MAXIMUM FIXED D.L.O.: 49 3/8" X 32 1/2", 0SERIES185ALUMINUMSINGLEHUNGWINDOW 52" X 72" NON -IMPACT HARDWARE SCHEDULE 2) METAL SWEEP LOCK AT 8" FROM EACH END INTERIOR MEETING RAIL 2) BLOCK AND TACKLE BALANCE AT JAM BS FLANGE & FINLESS ELEVATIONS IATAf 0TF_-it Q/ T ... ONAIL if 100 Luis R. Lomas P.E. FL No.: 62514 DRAWN: N.G. DWG NO. 08-02549 REV SCALE NTS JDATE 12/29/14 1 SHEET 2 OF 11 I. R06ERTO LOMAS P. E 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 r1lomasgIrlomaspe- Adpk K F HE REVISIONS F 2" 1 MAXM FRAME WIDTH _ F2'. JMAXMFRAME WIDTH REV DESCR PTION DATE APP OVED 2" MAX 0" AX O.0 2" MAX 2" MAX 0" AX O.0 2" MAX A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L.. r8 REVISED GLASS 10/02/17 R.L. 10" MAX O.C. 2" AX ME GHT 2" 1 . _[ / - 10" MAX O.C. 0 72" MAX FRAME HEIGHT A 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW EXTERIOR VIEW FININSTALLATION FIN INSTALLATION SEE CHART #2 FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART #2 FOR SMALLER UNITS REQUIRED ANCHORS DESIGN PRESSURE RATING IMPACTRATING 60.OPSF NONE NOTES: 1. MAXIMUM SASH SIZE: 51" X 36". 2. MAXIMUM SASH D.L.O.: 47 5/8" X 32 1/2". 3. MAXIMUM FIXED D.L.O.: 49 3/8" X 32 1/2". HARDWARE SCHEDULE METAL SWEEP LOCK AT 8" FROM EACH END INTERIOR MEETING RAIL BLOCK AND TACKLE BALANCE AT JAMBS CHART#2 Number of anchor locations required Frame Frame Width (in) Height 18 ' 00 24.00 30.00 36.00 42.00 48.00 52.00 in) H&S IJamb H&S Jamb H&S Jamb H&S Jamb H&S IJamb H&S Jamb H&S Jamb 24.00 3 3 3 3 4 3 5 3 5 3 6 3 6 3 30.00 3 4 3 4 4 4 4 5 4 6 4 6 4 36.00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 42.00 F3 5 3 5 4_ 5 5 5 5 5 6 5 6 5 48.00 3 6 3 6 4 6 5 6 5 6 6 6 6 6 54.00 3 6 4 6 6 -5 -6 6 6 61 6 60.00 3 1 1 3 1 7 4 7 6 7 5 7 6 7 66.00 3 8 1 3 8 4 8 1 5 8 5 8 6 6 72.00 3 8 1 3 11 A 4 8 IS 8 5 8 6 8 6 8 SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC P, L 0650WESTMARKETSTREET GRATZ, PA 17030-0370 E SERIES 185 ALUMINUM SINGLE HUNG WINDOW 0 5 52" X 72" NON —IMPACT I I FIN ELEVATIONS AT OF 6,Z DRAWN: DWG NO. REV OR N. G. 08-02549 9 SHEETSC ?/29/14 3 OF 11 L. ROPERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE. NG 27023 FL No.: 62514434-688-0609 r1lorrasoldomaspe—m I 10" MAX O.C. 2" AX ME GHT 2" 1 . _[ / - 10" MAX O.C. 0 72" MAX FRAME HEIGHT A 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW EXTERIOR VIEW FININSTALLATION FIN INSTALLATION SEE CHART #2 FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART #2 FOR SMALLER UNITS REQUIRED ANCHORS DESIGN PRESSURE RATING IMPACTRATING 60.OPSF NONE NOTES: 1. MAXIMUM SASH SIZE: 51" X 36". 2. MAXIMUM SASH D.L.O.: 47 5/8" X 32 1/2". 3. MAXIMUM FIXED D.L.O.: 49 3/8" X 32 1/2". HARDWARE SCHEDULE METAL SWEEP LOCK AT 8" FROM EACH END INTERIOR MEETING RAIL BLOCK AND TACKLE BALANCE AT JAMBS CHART#2 Number of anchor locations required Frame Frame Width (in) Height 18 ' 00 24.00 30.00 36.00 42.00 48.00 52.00 in) H&S IJamb H&S Jamb H&S Jamb H&S Jamb H&S IJamb H&S Jamb H&S Jamb 24.00 3 3 3 3 4 3 5 3 5 3 6 3 6 3 30.00 3 4 3 4 4 4 4 5 4 6 4 6 4 36.00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 42.00 F3 5 3 5 4_ 5 5 5 5 5 6 5 6 5 48.00 3 6 3 6 4 6 5 6 5 6 6 6 6 6 54.00 3 6 4 6 6 -5 -6 6 6 61 6 60.00 3 1 1 3 1 7 4 7 6 7 5 7 6 7 66.00 3 8 1 3 8 4 8 1 5 8 5 8 6 6 72.00 3 8 1 3 11 A 4 8 IS 8 5 8 6 8 6 8 SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC P, L 0650WESTMARKETSTREET GRATZ, PA 17030-0370 E SERIES 185 ALUMINUM SINGLE HUNG WINDOW 0 5 52" X 72" NON —IMPACT I I FIN ELEVATIONS AT OF 6,Z DRAWN: DWG NO. REV OR N. G. 08-02549 9 SHEETSC ?/29/14 3 OF 11 L. ROPERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE. NG 27023 FL No.: 62514434-688-0609 r1lorrasoldomaspe—m I 2" 1 . _[ / - 10" MAX O.C. 0 72" MAX FRAME HEIGHT A 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW EXTERIOR VIEW FININSTALLATION FIN INSTALLATION SEE CHART #2 FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART #2 FOR SMALLER UNITS REQUIRED ANCHORS DESIGN PRESSURE RATING IMPACTRATING 60.OPSF NONE NOTES: 1. MAXIMUM SASH SIZE: 51" X 36". 2. MAXIMUM SASH D.L.O.: 47 5/8" X 32 1/2". 3. MAXIMUM FIXED D.L.O.: 49 3/8" X 32 1/2". HARDWARE SCHEDULE METAL SWEEP LOCK AT 8" FROM EACH END INTERIOR MEETING RAIL BLOCK AND TACKLE BALANCE AT JAMBS CHART#2 Number of anchor locations required Frame Frame Width (in) Height 18 ' 00 24.00 30.00 36.00 42.00 48.00 52.00 in) H&S IJamb H&S Jamb H&S Jamb H&S Jamb H&S IJamb H&S Jamb H&S Jamb 24.00 3 3 3 3 4 3 5 3 5 3 6 3 6 3 30.00 3 4 3 4 4 4 4 5 4 6 4 6 4 36.00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 42.00 F3 5 3 5 4_ 5 5 5 5 5 6 5 6 5 48.00 3 6 3 6 4 6 5 6 5 6 6 6 6 6 54.00 3 6 4 6 6 -5 -6 6 6 61 6 60.00 3 1 1 3 1 7 4 7 6 7 5 7 6 7 66.00 3 8 1 3 8 4 8 1 5 8 5 8 6 6 72.00 3 8 1 3 11 A 4 8 IS 8 5 8 6 8 6 8 SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC P, L 0650WESTMARKETSTREET GRATZ, PA 17030-0370 E SERIES 185 ALUMINUM SINGLE HUNG WINDOW 0 5 52" X 72" NON —IMPACT I I FIN ELEVATIONS AT OF 6,Z DRAWN: DWG NO. REV OR N. G. 08-02549 9 SHEETSC ?/29/14 3 OF 11 L. ROPERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE. NG 27023 FL No.: 62514434-688-0609 r1lorrasoldomaspe—m I A 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW EXTERIOR VIEW FININSTALLATION FIN INSTALLATION SEE CHART #2 FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART #2 FOR SMALLER UNITS REQUIRED ANCHORS DESIGN PRESSURE RATING IMPACTRATING 60.OPSF NONE NOTES: 1. MAXIMUM SASH SIZE: 51" X 36". 2. MAXIMUM SASH D.L.O.: 47 5/8" X 32 1/2". 3. MAXIMUM FIXED D.L.O.: 49 3/8" X 32 1/2". HARDWARE SCHEDULE METAL SWEEP LOCK AT 8" FROM EACH END INTERIOR MEETING RAIL BLOCK AND TACKLE BALANCE AT JAMBS CHART#2 Number of anchor locations required Frame Frame Width (in) Height 18 ' 00 24.00 30.00 36.00 42.00 48.00 52.00 in) H&S IJamb H&S Jamb H&S Jamb H&S Jamb H&S IJamb H&S Jamb H&S Jamb 24.00 3 3 3 3 4 3 5 3 5 3 6 3 6 3 30.00 3 4 3 4 4 4 4 5 4 6 4 6 4 36.00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 42.00 F3 5 3 5 4_ 5 5 5 5 5 6 5 6 5 48.00 3 6 3 6 4 6 5 6 5 6 6 6 6 6 54.00 3 6 4 6 6 -5 -6 6 6 61 6 60.00 3 1 1 3 1 7 4 7 6 7 5 7 6 7 66.00 3 8 1 3 8 4 8 1 5 8 5 8 6 6 72.00 3 8 1 3 11 A 4 8 IS 8 5 8 6 8 6 8 SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC P, L 0650WESTMARKETSTREET GRATZ, PA 17030-0370 E SERIES 185 ALUMINUM SINGLE HUNG WINDOW 0 5 52" X 72" NON —IMPACT I I FIN ELEVATIONS AT OF 6,Z DRAWN: DWG NO. REV OR N. G. 08-02549 9 SHEETSC ?/29/14 3 OF 11 L. ROPERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE. NG 27023 FL No.: 62514434-688-0609 r1lorrasoldomaspe—m I SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC P, L 0650WESTMARKETSTREET GRATZ, PA 17030-0370 E SERIES 185 ALUMINUM SINGLE HUNG WINDOW 0 5 52" X 72" NON —IMPACT I I FIN ELEVATIONS AT OF 6,Z DRAWN: DWG NO. REV OR N. G. 08-02549 9 SHEETSC ?/29/14 3 OF 11 L. ROPERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE. NG 27023 FL No.: 62514434-688-0609 r1lorrasoldomaspe—m I r - 1/2" MIN EDGE DISTANCE WOOD FRAMING OR 2X BUCK BY OTHERS 1 1/4" MIN. EMBEDMENT BACKER ROD kAPPROVED 1/4" IAX. SEALANT SPACE 10 WOOD SCREW INTERIOR x EXTERIOR REASIONS DESCRIPTION DATE AP ROVED REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L. REVISED GLASS 10/02/17 1 R.L. 1 1/4" MIN. 1/4" MAX. EMBEDMENT SHIM SPACE 1 1/2" II' MN INTERIORLEDGE DISTANCE 10 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS BACKER RROD APPROVED EXTERIOR SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION SILL TO BE SET IN A BED OF APPROVED STRUCTURAL BACKER ROD SEALANT APPROVED SEALANT 1/4" MAX. SHIM SPACE SIGNED: 1211412017 DOD FRAMINGW OR 2X BUCK _ T MI WINDOWS AND DOORS, LLC R.. L 0 41BYOTHERS650WESTMARKETSTREETIGRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 0 VERTICAL CROSS SECTION 52" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS A fAT OF WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 0k" DRAWN: DWG NO. REV 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. N.G. 08-02549 a NAL 2. PERIMETER AND JOINTSEALANT BY OTHERS TO BE SCALE NTS JDAT' 12/29/14 1 SKET 4 OF 11, DESIGNED IN ACCORDANCE WITH ASTM E2112 L. ROBERTO LOMAS P. E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 FL No.: 62514 434-688-0609 r1lo—C&Irlomasp— 2" MIN EDGE DISTANCEr—r i m" STRUCTU BY OTHE APPROVED SEALANT 1/4" MAX. SHIM SPACE REMSIONS REV DESCRIPTION ATI A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L. 13 REVISED CLASS 10/02/17 R.L 1/4" MAX. 10 SMS OR SHIM SPACE SELF DRILLING SCREW 10 SIMS OR INTEPIOR SELF DRILLING INTERIOR SCREWS 1 L' E 0 N W R G NTER'0" 2 SlMIN. EDGE DISTANCE T_' XTEXTERIOR METAL EXTERIOR STRUCTURE BACKER ROD BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION BACKER ROD APPROVED SEALANT META STRUCTUF BY OTHEF SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4" MAX. SHIM SPACE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS DRAWN; DWG NO. G. 1 08-02549 A'r NTS JA" 12/29/14 1 SHEET 5 OF 11 L. ROBERTO LOMAS P.E. 1432 WOODFOR0 RD LEWISVILLE, NG 270231' 434-688-0609 r1lomaspirlomaspe- SIGNED: 1211412017 R L 0 5 TAT OF 0 Luis R. Lomas P. E. FIL No.: 62514 REVISIONS 2 1/2" MIN. REV DESCRIPTION DATE AP OVED EDGE DISTANCE A REVISED ANCHOR SPACING & CHARTS 07/11/1 'i CONCRETE/MASONRY 9 REVISED GLASS RL10/02/17 L BY OTHERS 4 4 4 1 1/4" MIN. OPTIONAL 1X BUCK EMBEDMENT 1 1/4" MIN. SEE NOTES 3 EMBEDMENT SHEET I 1/4" MAX. CONCRETE/MASONRY SHIM SPACE BY OTHERS 1/4" MAX. BACKER ROD SHIM SPACE APPROVED SEALANT 3/16" TAPCON 3/16" TAPCON INTERIOR INTERIOR 2 1/2" MIN. IBICKEDGE DISTANCE EXTERIOR BACKER ROD APPROVED OPTIONAL 11 SEALANT EXTERIOR SEE NOTES 3 — 7 SHEET 1 JAMB INSTALLATION DETAIL CONCRETEIMASONRYINSTALLATION BACKER ROD SILL TO BE SET IN A BED OF APPROVED NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. APPROVED STRUCTURAL 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE SEALANT SEALANT DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 1211412017 OPTIONAL 1X BUCK 1/4" MAX. MI WINDOWS AND DOORS, LLC SEE NOTE 3 — 7 SHEET 1 SHIM SPACE 650 WEST MARKET STREET P, L 0 4f, GRATZ, PA 17030-0370 NT' CONCRETE/MASONRY SERIES 185 ALUMINUM SINGLE HUNG WINDOW 0, "r' 5 BY OTHERS 44 52" X 72" NON —IMPACT 7- 4t/OFFLANGEINSTALLATIONDETAILSTAT Q! DRAWN: D111; 110. REV ZoRVD N.G. 08-02549 B AIL SCALE NTS I DATE 12/29/14 SHEET . OF 11 VERTICAL CROSS SECTION L. ROBERTO LOMAS P. E. Luis R. Lomas P.E. CONCRETEIMASONny INSTALLATION 1432 WOODFORD RD LEWISVILLE. NC 27023 FL No.: 62514434-688-0609 illomasCaNrldmaspe— 1/2" MIN EDGE DISTANCE WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD 4" MAX. APPROVED MT7SEALANT k SHI SPACE 10 WOOD SCREW 1 1/4" MIN. EM13EDMENT 1 1/2" MIN EDGE DISTANCE r_l 10 WOOD SCREW REVISIONS DESCRIPTION DATE I 11 OVED REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L. REVISED CLASS 10/02/17 R.L. 1/4" MAX. SHIM SPACE INTERIOR WOOD FRAMING EXTERIOR OR 2X BUCK BY OTHERS APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION SILL TO BE SET IN A BED OF APPROVED STRUCTURAL BACKER ROD r SEALANT APPROVED SEALANT 1/4" MAX. SHIM SPACE SIGNED: 1211412017 WOOD FRAMING MI WINDOWS AND DOORS, LLC OR 2X BUCK BY OTHERS 650 WEST MARKET STREET N P, to GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 0 6 VERTICAL CROSS SECTION 52" X 72" NON -IMPACT FINLESS INSTALLATION DETAILS TAT OF WOOD FRAMING OR 2X BUCK INSTALLATION n G NO. REV 0* k,. * 4 'z MD.. NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, 08 02549 5'/ONAI- - NOT SHOWN FOR CLARITY. TCALE NTS JDATE 12/29/14 1 SHEET 7 OF 11 IS/ it I I% 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 L. ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 FIL No.: 62514 434-686-0609 rllomasLWlrl-spe.com REVISIONS 2 1/2" MIN. REY EDGE DISTANCE DESCRIPTION DATE AP ROVED EDGE"IS Al' A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L. CONCRETE/MASONRY 13 REVISED GLASS BY OTHERS OPTIONAL ix BUCK 4 4 1 1/4" MIN. 1 1/4" MIN SEE NOTES 3 — 7 EMBEDMENT EMBEDMENT SHEET I CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK SEE NOTES 3 7 1/4" MAX. SHEET 1 BACKER ROD SHIM SPACE APPROVED SEALANT 3/16" TAPCON 1/4" MAX. 3/16" TAPCON SHIM SPACE INTERIOR INTERIOR 2 112" MIN. q.All EDGE DISTANCE EEXTERIOR EXTERIOR BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETEIMASONRYINSTALLATION SILL TO BE SET BACKER ROD IN A BED OF APPROVED NOTES: APPROVED STRUCTURAL 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, SEALANT SEALANT NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE OPTIONAL 1X BUCK 1/4" MAX. DESIGNED IN ACCORDANCE WITH ASTM E2112 SEE NOTE 3 — 7 llrFSHIM SPACE SIGNED: 1211412017 SHEET I MI WINDOWS AND DOORS, LLC wkIiIIIII/// CONCRETE/MASONRY 650 WEST MARKET STREET q, R L 0 BY OTHERS GRATZ, PA 17030-0370 C, N,9'. .(p SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —'IMPACT FINLESS INSTALLATION DETAILS T Afl OF DRAWN: DWC NO. 0 0110REV VERTICAL CROSS SECTION N.G. 08-02549 B CONCRE:EIMASONRYINSTALLATION SCALE NTS DATE 12/29/14 1 SHEET 9 OF 11 L, ROBERTO LOMAS RE 1432 WOODFORD RD LEWISVILLE, AIC 27023 Luis R. Lomas P.E. 688-0609 rilomas@lrlomaspe.com FL No.: 62514 APPROVED SEALANT BEHIND FIN 7/16" MIN EDGE DISTANCE INTERIOR EXTERIOR 1 1/4" MIN. EMBEDMENT WOOD FRAMING BY OTHERS 1/4" MAX. SHIM SPACE 8 WOOD SCREW WOOD FRAMING 1/4" MAX BY OTHERS SHIM SPACE 8 WOOD SCREW 1 INTERIOR MIN. EMBEDMENT APPROVED SEALANT BEHIND FIN 7/16" MIN EXTERIOR EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION REVISIONS DESCRIPTION DATE I APIR.-D REVISED ANCHOR SPACING & CHARTS 07/11/16 R.. . REVISED GLASS 10/02/17 1 R.L. ffO WUUU :A.,KLW NOTES: U- 1/4" MAX 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, F SHIM SPACE NOT SHOWN FOR CLARITY, 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 1211412017 7/16" MIN EDGE DISTANCE MI WINDOWS AND DOORS, LLC APPROVED WOOD 650 WEST MARKET STREET GRATZ, PA 17030-0370 L o SEALANT FRAMING S' (P 5- BEHIND FIN 1 1/4" MIW BY OTHERS SERIES 185 ALUMINUM SINGLE HUNG WINDOW 5 LIVIOLL) MENT 52" X 72" NON —IMPACT VERTICAL CROSS SECTION FIN INSTALLATION DETAILS Af; OF 0 T WOOD FRAMING OR 2X BUCK INSTALLATION DRAWN: 7G NO. REV R N.G. SCALE 08-02549 a 0 INTS DATE 12/29/14 1 SHEET 10 OF il 011111111 L. ROBERTO LOMAS P. E Luis R. Lomas P.E. f432 WOODFORD HD LEWISVILLE, NC 27023 FIL No.: 62514434-688-0609 rIlomas@lrlcmaspe- All METAL STRUCTURE BY OTHERS APPROVED SEALANT 2" MIN EDGE DISTANCEIr I 1/4" MAX. SHIM SPACE REVISIONS DESCRIPTION DATE AP ROVED REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L REVISED GLASS 10/02/17 R. L. 1/4" MAX. SHIM SPACE 10 SMS OR SELF DRILLING 10 SMS OR INTERIOR SCREW SELF DRILLING WTEPIlNTEPIOP SCREWS T_ 1/2" 31wMIN. EDGE DISTANCE I EXTERIOR METAL BACKER ROD STRUCTURE APPROVED EXTER10kR BY OTHERS SEAL -ANT JAMB INSTALLATION DETAIL x SILL TO BE SET IN A BED OF METAL STRUCTURE INSTALLATION BACKER ROD APPROVED SEALANT APPROVED STRUCTURAL SEALANT 1/4" MAX. SHIM SPACE SIGNED: 1211412017 META MI WINDOWS AND DOORS, LLC S CTURL__- TRU E BY SOTHER 650 WEST MARKET STREET P, L 0 41 rENv* GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW VERTICAL CROSS SECTION 52" X 72" NON --IMPACT 0 METAL STRUCTURE INSTALLATION FINLESS INSTALLATION DETAILS r_-A41T frOF NOTES: 0 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR DRAWN N. G. DWG 110. 08-02549 REV B pl Nr Lp ' i - . . . - " O/ONALCLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE SCALE NTS I DATE 12/29/14 SHEET 13 OF 11 DESIGNED IN ACCORDANCE WITH ASTM E2112 L. ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 FL No.: 62514434-688-0609 r1lo—CWItlomaspe— F2 3/16" 13/16" ILF FLANGE FRAME HEAD CM- 18501 AL UMINUM 6063- T5.050" THICK 2 5/16" — 1 3 3/8" L INGE FRAME SId CM- 18502 ALUMINUM 6063- T5.055" THICK 1 5/8" [- ILE CM- 18505 ALUMINUM 6063-T5.062" THICK I A 71AIt- p 174 n RIGID PVC.050" THICK 1 7/8" - 2 3/16" FLANGE FRAME JAMB CM- 18503 ALUMINUM 6063-T5.050" THICK 2 5/16" 2 13/1 E FINLESS FRAME SILL CM- 18554 ALUMINUM 6063-T5 .055'THICK 1 7/16" 2 /16" 5 LE SASH BOTTOM RAIL CM- 18555 ALUMINUM 6063-T5.050" THICK 11 3/8 15/16" T__l' SASH STILE CM- 18507 ALUMINUM 6063-T5.050"THICK 2 3/16" 1 5/16" 1 FINLESS FRAME HEAD CM- 18553 ALUMINUM 6063- T5.050" THICK 1 3/8f- 2 3/16" FINLESS FRAME JAMB CM- 18513 ALUMINUM 6063-T5.050' THICK 2 5/16" 2 3 16 3 3/4" 2 5/16" FIN FRAME HEAD CM- 18509 CM- 18508 ALUMINUM 6063-T5.055" THICK ALUMINUM 6063-T5 _050'THICK 2 3/ T23/16" 2" L ME RAIL FIN FRAME JAMB CM- 185 10 CM- 18504 ALUMINUM 6063-T5.050" THICK ALUMINUM 6063-T5.055" THICK REVISIONS ' I REV I DESCRIPTION DATE APPROVED A REVISED ANCHOR SPACING & CHARTS 07/11/16 R. L. 6 REVISED GLASS I D/O 2/17 R.L. 5/8" — — 1/8" ANN. — — 1/8" ANN. 1/8" ANN. 090 PVB BY KURARAY METAL REINFORCED BUTYL SPACER EXTERIOR INTERIOR 1/2 BITE SILICONE SEALANT r, SETTING BLOC GLAZING DETAIL MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON -IMPACT COMPONENTS IN: QWG NO. N.G. 1 08-0 549 SCALE NTS I—E 12/29/14 J HEETjj OF 11 L. ROBERTO LOMAS RE 1432 WOODFORD RD LEWISVILLE, NG 27023 434-688-0609 dIoasplrlo-p-- SIGNED: 1211412017 P, L oNra r, E N S' .:,p 0 5 f tAfrO'F 0 TEV B 0 N A I Luis R. Lomas P.E. FL No.: 62514 Florida Buildinc, Code OnlineZD Page 1 of 3 IN It NT7 05 81 AN11to 15CIS Home Log In 1 User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application Lis > Application Detail M FL15349-R9FL # Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved MI Windows and Doors 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Windows Fixed Certification Mark or Listing American Architectural Manufacturers Association Steven M. Urich, PE 2-' Validation Checklist - Hardcopy Received Standard Year AAMA 506 2011 AAMA/WDMA/CSA 101/I.S. 2/A440 2008 Method 1 Option A 12/31/2017 12/31/2017 01/04/2018 https://vr.floridabuilding.orc,/pr/pr app dtl.aspx?param=wGEVXQwtDqtH8572qvdWI... 1/31/2018 j Florida BuildIg Code Online Page 2 of 3 Summary of Products FL# Model, Number or Name Description 15349.1 185 PW 73 x 72 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R9.0 CAC APC 12786,pdf Approved for use outside HVHZ: Yes FL1 3..49 R9 C CAC AE(L12237.p f Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +60/-60 04/03/2018 Other: CW-PG60 Installation Instructions FL15349 R9 II 08-02.357B.Ipd Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL15349 R9 AE 513124B.I)d Created by Independent Third Party: Yes 15349.2 ---185 PW 159 x 54 Triple CHS Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLIS349 R9 C CAC APC 15350.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 01/24/2021 Design Pressure., +55/-55 Installation Instructions Other: R-PG55 FL15349 R9 II 08-02949.pd Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL15349 R9 AE 51378a.pdf Created by Independent Third Party: Yes 15349.3 18S PW Impact 72 x 72 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R9 C CAC APC 15454.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/25/2021 Design Pressure: +55/-55 Installation Instructions Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FL15349 R9 II 08-02948.Qd consisted of 5/32" tempered exterior - spacer - 5/32" Verified By: Luis R. Lomas, PE 62514 annealed / 0.100 Solutia Saflex HP / 5/32" annealed. Glass Created by Independent Third Party: Yes was bedded in Pecora 896 silicone with 5/8" glass bite. Evaluation Reports FL15349 R9 AE 513782.[)d Created by Independent Third Party: Yes 15349.4 1185 PW Impact 159 x 54 Triple CHS Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R9 C CAC APC 8272.odf Approved for use outside HVHZ: Yes FL15349 R9 C CAC APC 8273,odf Impact Resistant: Yes Quality Assurance Contract Expiration Date Design Pressure: +55/-55 01/24/2021 Other: FW-R55, Missile Level D, Wind Zone 3. Glass Installation Instructions consisted of 1/8" annealed exterior - spacer - 3/32" FL15349 R9 II 08-01614B.r)d annealed / 0.090 Solutia PVB / 3/32" annealed. Glass was Verified By: Luis Roberto Lomas 62514 bedded in Pecora 896 silicone with 5/8" glass bite. Created by Independent Third Party: Yes Evaluation Reports FL15349 R9 AE 512278B.L)d Created by Independent Third Party: Yes 15349.5 96 x 60 insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R9 C CAC APC 7962.odf Approved for use -outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant., Yes 12/05/2020 Design Pressure: +55/-55 Installation Instructions Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FL15349 R9 II 08-01613B.r)d consisted of 5/32" annealed exterior - spacer - 5/32" Verified By: Luis Roberto Lomas 62514 annealed / 0.100 Solutia Saflex HP / 5/32" annealed. Glass Created by Independent Third Party: Yes was bedded in Pecora 896 silicone with 5/8" glass bite. Evaluation Reports F1-15349 R9 AE 512277B.pd Created by Independent Third Party: Yes F--- -'] F.--- 11 Contact U :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone, 850-487-182 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. ;: Privacy Statement :: Accessibilty Statemen :: Refund Statemen https://www.flon*dabuilding.orc,/pr/pr app dtl.aspx?param=wGEVXQ"qDqtH8572qvdWI... 1/3) 1/2018 Florida Building Code Online Page 3) of 3 Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487. 1395. *Pursuant to Sect ion 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the ficensee. However email addresses are public record. if you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: R7R- M Credit Card, safe https://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wGEVXQwtDqtH8572qvdWI... 1/31/2018 NOTES: 1 . THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASON RY/CO NCR ETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1X BUCK 15 NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16- OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED ALUMINUM 6063—T5. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #6 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. REASIONS DESCRIPnON DATE APPIR D REVISED INSTALLATION DETAILS 06/01/15 R.L. REVISED NAME AND ADDRESS 10/27/16 R.L. 15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME INTO MASON RY/CONC RETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT. 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,OOOPSI MINIMUM. D. METAL STRUCTURE: STEEL 18CA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063—T5 FU=30KS) .048" THICK MINIMUM 20. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN IN SHEET 2. MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT NOTES TABLE OF CONTENTS DRAWN: 13 NO SHEET NO. DESCRIPTION J. L. 7 08 —02357 1 NOTES SCALE NTS I DAIE 09/03/14 1 SHEET 1 OF 12 2 3 ELEVATIONS, CHARTS AND GLAZING DETAILS 4 12 INSTALLATION DETAILS L. ROBERTO LOMAS P. E 1432 WOODFORD RD LEWISVILLE, IVC 27023 434-688_0609 SIGNED: 1111512016 R* Lo p a TAT OF R B 0 Luis R. Lomas P.E. FIL No.: 62514 REVISIONS 72 1/2" MAX FRAME WIDTH REV DESCRIPTION DATE APPROVED 6" MAX 18 MAX D.C. P_ 6" MAX 1 NOTES: A REVISED INSTALLATION DETAILS 06/01/1 6" MAX 1. MAXIMUMO.L.O.: 69314"X68314" B REVISED NAME AND ADDRESS 10/27/ T_ I CHART#I 18" Number of anchors required (w0houf rigid filters) MAX O.C. Frame Frame widtA (in) HOght 24.0000 30 0 36.00 42 0 48.00 54.00 60.00 66 0 72.50 in) HAS ambIb HAS ambi HAS PambI HAS Jamb HAS Pambl HAS Jamb HAS amb HAS amb HAS amb 24.00 2 2 2 2 1 3 1 2 3 2 3 1 2 4 2 4 2 4 2 5 2 30.00 2 2 2 2 3 1 2 3 2 3 2 4 2 4 1 2 4 2 5 2 71 1/2" 36.00 24 2 3 2 3 3 3 3 3 3 3 4 3 4 3 5 3 1 5 1 3 MAX 42.00 2 3 2 3 3 3 3 3 3 3, 4 3 5 3 5 3 6 3 FRAME 49.00 2 3 2 3 3 3 3 3 3 3 4 3 5 3 6 3 6 3 HEIGHT 00 00 54.00 2 4 2 4 3 4 3 4 3 4. 4 4 5 4 6 4 7 4_ 60.00 2 4 2 4 3 4 3 5 3 5 4 5 5 5 6 5 7 5 4 66.00 2 4 2 4 3 5 3 5 1 3 6 4 6 5 6 6 6 7 F7150 1 2 1 5 1 2 1 5 3 5 3 66 F3 6 REFER TO CHARTS ------SERIES 185 ALUMINUM FIXED WINDOW 1 & #2 EXTERIOR VIEW FOR NUMBER OF CHART#2 ANCHORS REQUIRED Number of anchors required (with rigid fillers) 72 1/2" MAX FRAME WIDTH Frame Frame width fin) 6" MAX 18" MAX D.C. Pleighl 24.00 H&Spamb 3000 36.00 42.00 48.00 5400 60.00 66.00 72.50 6" MAX in) HAS Jamb HAS Jambl HAS Pamb HAS Jamb HAS amb HAS Jamb HAS amb HAS Jamb 24.00 2 2 2 2 3 2 1 3 2 3 2 4 2 4 2 4 2 5 2 30.00 2 2 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 6" 0// 36.00 42.00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 4 3 5 3 323233333334343435 48.00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 4N44 3 5 3 54.00 2 4 2 4 3 4 3 4 3 4 4 4 4 4 4 4 5 4 60.00 2 4 2 4 3 4 3 4 3 4 4 4 4 4 4 4 5 4 71 1/2- 16 66.00 2 4 2 4 3 4 3 4 4 4 4 4 4 4 5 4 MAX MAX D.C._ 71.50 L 1 2 5 2 1 6 1 3 1 5 1 3 5 1 4 5 j 4 5 1 5 1 FRAME T_ SEE SHEETS 4-7 FOR INSTALLATION DETAILS HEIGHT 00 REFER TO CHARTS --' SERIES 185 ALUMINUM FIXEO DESIGNER WINDOW 1 & #2 EXTERIOR VIEW FOR NUMBER OF ANCHORS REQUIRED DESIGN PRESSURE RATING IMPACTRATING 60.OPSF NONE SIGNEO: 1111512016 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 E Nq SERIES 185 ALUMINUM FIXED WINDOW 51 73" X 72" NON -IMPACT FLANGE & FINLESS ELEVATION & CHARTS TAT OF 0. 0, o'. OR I IONAL 1/0111m0 DRAWN: DWG J.L. 110- 08-02357 REV B_ SCALE NTS I-E 09/03/14 1 SHEET 2 OF 12 L. ROBERTO LOMAS P. E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688_0609 ttlomas@lrlomaspe.com Luis R. Lomas P.E. FL No.: 62514 71 F! HI 6" MAX 72 1/2 MAX FRAME WIUIH 18" MAX D.C. 6- _rAX 1 00 MAX O.C. 1/2" IAX AME IGHT 4// oo 6" MAX REFER TO CHART #3 _ l___SSER1ES 185 ALUMINUM FIXED WINDOW FOR NUMBER OF EXTERIOR VIEW ANCHORS REQUIRED 72 1/2- MAX FRAME WIDTH 6 " MAX 181, MAX D.C. 6" MAX 00 18 11 MAX D.C. 71 1/2" MAX FRAME HEIGHT REFER TO CHART #3 FOR NUMBER OF SERIES 185 ALUMINUM FIXED DESIGNER WINDOW ANCHORS REQUIRED EXTERIOR VIEW DESIGN PRESSURE RATING I IMPACTRATINGJ 60. OPSF NONE NOTES: 1. MAXIMUMD.L.O.: 69314"X68314" REVISIONS DESCRIP71ON 11— 1 -lR.VE. REVISED INSTALLATION DETAILS 06/01/15 R.L. REVISED NAME AND ADDRESS 10/27/16 R.L. CHART#3 Number of anchors required (fin installation) Frame Frame width (in pleightght 24.00 30.00 36.00 42.00 48,00 54.00 1 60.00 66.00 72.50 in) m) HAS amb H&Spamb HAS mbamb HAS J.!,b HAS Jamb HAS J.,,,b HAS Pa.b HAS Ja.b HAS amb 24.00 3 3 3 3 3 3 4 3 4 3 4 3 5 3 5 3 6 3 30.00 3 3 3 3 3 3 4 3 4 3 4 3 5 3 5 3 6 3 36.00 3 3 3 3 3 3r 4 3 41 3 4 3 5 3 5 3 6 3 42.00 3 4M16 3 4 3 411444 4 4 4 5 4 5 4 6 4 48.00 3 4 3 4 3 4 4— 4 4 4 4 4 5 4 5 4 6 4 1 54.00 3 4 3 4 3 4 4 4 4 4 4 4 5 4 5 4 6 4 60.00 3 3 5 3 5 4 5 4 5 4 5 5 5 5 5 6 5 66.00 1 3 5 3 5 3 5 5 4 5 4 5 5 5 5 5 6 5136366116461651111 SEE SHEET 8 FOR INSTALLATION DETAILS MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 1 030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FIN ELEVATION & CHART DRAWN: 75w- I-- J.L. 1 08702357 5cALr NTS I DATE 09/03/14 , I SHEET 3 OF 12 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 r1lomas(a)Irlomasne.war SIGNED: 1111512016 v, L Z_- TAT OFlhj:= 0 A 0 ROt 41;//61YAC 1 /111111110 Luis R. Lorn as P. E. FL No.: 62514 1/2" MIN. EDG DISTANCE WOOD FRAMING 1 1/4" MIN. METAL OR 2X BUCK EMBEDMENT STRUCTURE BY OTHERS BY OTHERS ir1/ MAX BACKER ROD SHIM SPACEI' BACKER ROD APPROVED APPROVED SEALANT SEALANT 1010 WOOD SCREW EXTERIOR EXTERIOR I A,,,. NTERIOR 10 WOOD SCREW RlQID FILLER BACKER ROD BACKER ROD — APPROVED 1/4" MAX. APPROVED SEALANT SHIM SPACE SEALANT WOOD FRAMING 1 1/4" MIN. METAL OR 2,X BUCK BY OTHERS EMBEDMENT STRUCTURE BY OTHERS 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4" MIN. /4" MAX. EMBEDMENT F S HIM SPACE T- 12DI, INTERIOR E IAN CrEDG 'T _ / 10 WOOD SCREW WOOD FRAMING EXTERIOR OR 2X BUCK Al BY OTHERS BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION 3 4" MIN EDGE DISTANCE l/4" MAX. SHIM SPACE 10 SMS OR SELF DRILLING SCREW INTERIOR 10 SMS OR SELF DRILLING SCREW RIGID FILLER 1/4" MAX. FSHIM SPACE 3/4" MIN EDGE DISTANCE METAL STRUCTURE INSTALLATION 1/4" MAX. SHIM SPACE 3/4" MIN. EDGE DISTANCE INTERIORLI I 10 SMS OR SELF DRILLING SCREWS EXTERIORfMETAL STRUCTURE BACKER RRODD BY OTHERS APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION REVISIONS REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/01/15, 1 R.L. 1BREVISEDNAMEANDADDRESS '3 R L NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC P, L 650 W. MARKET ST. GRATZ, PA 17030 l, S 0 r, ENO* .,pZ- .. $1* . 0 61SERIES185ALUMINUMFIXEDWINDOW 73" X 72" NON —IMPACT OFFINLESSINSTALLATIONDETAiLSWITHOUTFILLERSTAX 0 DRAWN: TWG NO. EV_ J. L. 08-02357 B W/ONAC,\' Luis R. Lomas P.E. FL No.: 62514 SCALE NTS I DATE 09/03/14 1 SHEET 4 OF 12 L. ROBERTO LOMAS P. E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 2 1/2" MIN. EDGE DISTANCE CONCRETE/IVIASONRY _ xBYOTHERS 14 4 1 1/4" MIN. OPTIONAL 1X BUCK EMBEDMENT SEE NOTES 3 — 7 SHEET 1 BACKER ROD 1/4" MAX. rAPPROVEDSHIM SPACE SEALANT 3/16" TAPCON EXTERIOR INTERIOR 3/16" TAPCON BACKER ROD APPROVED SEALANT 1/4" MAX. OPTIONAL 1X BUCK SEE NOTE 3 — 7 SHIM SPACE SHEET 1 CONCRETE/IVASONRY BY OTHERS 44 1 1/4" MIN. EMBEDMENT 2 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETEIMASONRY INSTALLATION REVISIONS DESCRIPTION I DATE APP OVED REVISED INSTALLATION DETAILS 06/01/15 R.L. REVISED NAME AND ADDRESS 10/27/16 R.L 1 1/4" MIN. EMBEDMENT CONCRETE/MASONRY BY OTHERS /4" MAX. OPTIONAL 1X BUCK SHIM SPACE SEE NOTES 3 — 7 SHEET 1 3/16" TAPCON INTERIOR NOTES* 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TOBE DESIGNED IN ACCORDANCE WITHASTME2112 2 1/2" MIN. EDGE DISTANCE EXTERIOR B.AACKE ROD APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETEIMASONRYINSTALLAPON SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. S P, L GRATZ, PA 17030 zz-S' 0 5SERIES185ALUMINUMFIXEDWINDOW 73" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS WITHUT FILLERS orTAT0F 0- 3110zolDRAWN: I'D IVT_G J. L. 7 B f0NA 1/111m.10 Luis R. Lomas P.E. FIL No.: 62514 SCALE NTS I PATE 09/03/14 SHEET 5 OF 12 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NG 27023 434-668-0609 rIIcmas@)lrlomaspe.mm 1/2" MIN ' EDGE DISTANCE WOOD FRAMING 1/4" MIN. METAL OR 2X BUCK 'EMBEDMENT STRUCTURE BY OTHERS BY OTHERS BACKER R D 1/4 MAX 0 SHIM SPACE BACKER ROD APP ROVED & APPROVED SEALANT RIGID FILLER SEALANT 10 WOOD SCREW BACKER ROD APPROVED WOOD FRAMING OR 2X BUCK BY OTHERS IOR EXTERI, NTERIOR 10 WOOD SCREW RIGID FILLER 1/4" MAX. SHIM SPACE BACKER ROD - APPROVED SEALANT 1 1/4" MIN. METAL- STRUCTURE EMBEDMENT BY OTHERS 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4" MIN. 1/4" MAX. EMBEDMENT SHIM SPACE V RIGID FILLER 1/2 MIN. ED INTERIOR 10 WOOD SCREW WOOD FRAMING -/v EXTERIOR OR 2X BUCK Al BY OTHERS BACKER ROD APPROVED SEALANT JAM13 INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION 3/4" MIN r EDGE DISTANCE 1/4" MAX. SHIM SPACE RIGID FILLER 10 SMS OR SELF DRILLING SCREW INTERIOR SMS OR DRILLING W FILLER 1/4" MAX. SHIM SPACE 3/4" MIN EDGE DISTANCE METAL STRUCTURE INSTALLATION 1/4" MAX SHIM SPACE T_ RIGID FILLERRIGIDFLLEl 3/4" MIN. EDGE DISTANCE INTERIORT, 10 SMS OR SELF DRILLING SCREWS EXTERIOR METAL STRUCTURE BACKER ROD BY OTHERS APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION REVISIONS REV ESCRIP ON DATE: I APP OVED 01/15 L. A RCVISED INSTALLATION DETAILS 10 ll L B REVISED NAME AND ADDRESS 1 10/27/16 1 R.L. NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 1111512016 MI WINDOWS AND bOORS, LLIC 650 W. MARKET ST. V., L 0 4f G RATZ , PA 17030 S' SERIES 185 ALUMINUM IXED WINDOW 73" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS WITH RIGID FILLERS A TAT Or 0 DRAWN- NO. REVG J.L. 08-02357 B Luis R. Lomas P.E. SrALE NTS 09/03/14 T E- 5 OF 12 L. R013ERTO LOMAS P. E 1432 WOODFORD RD LEWISVILLE, NC 27023 FIL No.: 62514 434-688-0609 r1tomasCaWfamaspe.com CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK SEE NOTES 3 - 7 SHEET 1 BACKER ROD APPROVED SEALANT EXTERIOR BACKER ROD APPROVED SEALANT OPTIONAL IX BUCK SEE NOTE 3 - 7 SHEET I CONCRETE/MASONRY BY OTHERS 2 1/2" MIN ' - 1EDGEDISTANCE 4 1 1/4" MIN. 4 EMBEDMENT 1 1/4" MIN. EMBEDMENT 1/4" MAX. SHIM SPACE CONCRETE/MASONRY BY OTHERS RIGID FILLER OPTIONAL 1X BUCK SEE NOTES 3 - 7 SHEET 1 3/16" TAPCON INTERIOR 3/16" TAPCON 3/16" TAPCON RIGID FILLER 1/4" MAX. HIM SPIN& S I 2 1/2" MIN. EDGE DISTANCE 14 1 1/4 MIN. EMBEDMENT 4. 4 2 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETEIMASONRYINSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WIT14 ASTM E2112 REVISIONS REV DESCR PTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/01/15 R.L. 8 REVISED NAME AND ADDRESS 10/27/16 1 R.L. 1/4" MAX. SHIM SPACE RIGID FILLER INTERIORINT EXTERIOR BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETEIMASONRYINSTALLATION SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC 550 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NbN—IMPACT FINLESS INSTALLATION DETAILS WITH RIGID FILLERS X TAT or DRAWN: 110. REV J. L. IWG 08-02357 B 0 IVAL SCALE NTS I DATE 09/03/14 1 SHEET 7 OF 12 L. ROBERTO LOMAS P.E Luis R. Lomas P.E. f432 WOODFORD RD LEWISVILLE, NC 27023 FL NO.: 62514 434-688-0609 r1lomasCWIrlomaspe.Com WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANTIBEHINDFLANGE 1/2" MIN. EDGE DISTANCE 1 1/4" MIN EMBEDMEN 1/4" MAX. SHIM SPACE 10 WOOD SCREW METAL STRUCTURE BY OTHERS BACKER ROD & APPROVED SEALANT BEHIND FLANGE 1/4" MAX. SHIM SPACE 10 SMS OR LF DRILLING REW REVISIONS DESCRIPTION DATE I API DIED REVISED INSTALLATION DETAILS 06/01/15 R.L. REVISED NAME AND ADDRESS 10/27/16 R.L. EXTERIOR EXTERIOR INTERIOR INTERIOR 10 SMS OR 10 WOOD SCREW SELF DRILLING SCREW RIGID FILLER BACKER ROD & BACKER ROD RIGID FILLER APPROVED SEALANT 1/4" MAX. APPROVED SEALANT BEHIND FLANGE t SHIM SPACE BEHIND FLANGE 1/4" MAX. SHIM SPACE NOTES: WOOD FRAMING OR 2X BUCK 1 1/4 MIN. METAL STRUCTURE TE 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. BY OTHERS EMBEDMENT BY OTHERS S 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE 1 3/4" MIN DESIGNED IN ACCORDANCE WITH ASTM E2112 1/2" MIN EDGE DISTANCE EDGE DISTANCE VERTICAL CROSS SECTION VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION WOOD FRAMING OR 2X BUCK INSTALLATION 1/4" MAX. 1 1/4" MIN. 1/4" MAX* SHIM SPACE EMBEDMENT SHIM SPACE F- I T-- 1/2" MIN. 3/4" MIN. INTERIORfNT1 EDGE DISTANCE EDGE DISTANCE SIGNED: 1111512016 INTERIOR MI WINDOWS AND bOORS, LLC 650 W. MARKET ST. 9 L / 10 WOOD 10 SMS OR GRATZ, PA 17030 01 SCREW SELF DRILLING SERIES 185 ALUMINUM FIXED WINDOW 0 61 SCREWS 73" X 72" NON —IMPACT WOOD FRAMING OR 2X BUCK EXTERIOR METAL EXTERIOR FLANGE INSTALLATION DETAILS WITHOUT FILLERS TAT OF. BY OTHERS BACKER ROD & STRUCTURE BACKER ROD & DRAWN: jDWG NO. RIV_ ORIDt APPROVED SEALANT BY OTHERS APPROVED SEALANT J.L. 08-02357 B ONAI- BEHIND FLANGE BEHIND FLANGE I DATE I SHEET 8SCALENTS09/03/14 OF 12 0II/ou W1 JAMB INSTALLATION DETAIL JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE INSTALLATION L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 Luis R. Lomas P. E. 434-688-0609 rIIomas@)Irjomasp&.wRT FL No.: 62514 REVISIONS DATE APR VIED 2 1/2" MIN REV A DESCRIPTION REVISED INSTALLATION DETAILS 06/01/15 R.L. EDGE DISTANCE 8 REVISED NAME AND ADDRESS I OIT11 111 R. L. CONCRETE/MASONRY BY OTHERS 1 1/4" MIN. 14. 1 1/4" MIN. EMBEDMENT OPTIONAL IX BUCK EMBEDMENT SEE NOTES 3 — 7 SHEET I YCONCRETE/MASONRY 4 BACKER ROD & 1/4" MAX. BY OTHERSS 1/4" MAX. APPROVED SEALANT SHIM SPACE SHIM SPACE BEHIND FLANGE OPTIONAL 1X BUCKC' SEE NOTES 3 — 771SHEET1 3/16" TAPCON EXTERIOR INTERIOR 3/16" TAPCONC INTERIOR 3/16" TAPCON BACKER ROD & APPROVED SEALANT BEHIND FLANGE 1/4" MAX. 2 1/2" 5 iTERIOROPTIONAL1XBUCK SHIM SPACE MIN. SEE NOTE 3 — 7 EDGE SHEET 1 DISTANCE 7 BACKER ROD & CONCRE TE/MASONRY BY OTHERS 4 1 1/4" MIN. APPROVED SEALANT FLANGE14 EMBEDMENT BEHIND JAMB INSTALLATION DETAIL CONCRETEIMASONRY INSTALLATION 2 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETEIMASONRY INSTALLATION SIGNED: 1111512016 NOTES: I. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS WITHOUT FILLERS DRAWN: DWG NO. J. L. 08 023 SCALE NTS I DATE 09/03/1 SHEET 9 OF 12 L. R013ERTO LOMAS P. E 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomasplr pmaspe.mm V, L C) 0 fAT OF Z0RVD?"GN l/0NA`l_ Millit\0 Luis R. Lomas P.E. FIL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANTIBEHINDFLANGE 2 " MIN. EDGE DISTANCE 1 1/4" MIN. T 1/4" MAX. SHIM SPACE RIGID FILLER 10 WOOD SCREW METAL STRUCTURE BY OTHERS BACKER ROD & APPROVED SEALANT BEHIND FLANGE 1/4" MAX. SHIM SPACE GID FILLER 10 SMS OR UF DRILLING REW REVISIONS REV DESCRIPTION DATE 1PI1.V0 A REVISED INSTALLATION DETAILS !dBREVISEDNAMEANDADDRESS10/27/16 R.L. EXTERIOR EXTERIOR INTERIOR INTERIOR 10 SMS OR 10 WOOD SCREW SELF DRILLING SCREW BACKER ROD & RIGID FILLER BACKER ROD & RIGID FILLER APPROVED SEALANT 1/4" MAX. APPROVE0 SEALANT BEHIND FLANGE SHIM SPACE BEHIND FLANGE 1/4" MAX. FSHIM SPACE NOTES: WOOD FRAMING OR 2X BUCK lilt 1 1/4" MIN. METAL STRU CTURE 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. BY OTHERS EMBED MENT BY OTHERS 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 1 3/4" MIN 1/2" MIN EDGE DISTANCE EDGE DISTANCE VERTICAL CROSS SECTION VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION WOOD FRAMING OR 2X BUCK INSTALLATION 1/4" MAX 1 1/4" MIN. 1/4" MAX. SHIM SPACE EMBEDMENT SHIM SPACE IRIGIDFILLERRIGIDF LLE1 IRIGID FILLERRGI'D FLL.ER 1/2" MIN. 3/4" MIN. NIT, INTERIOR EDGE DISTANCE EDGE DISTANCE SIGNED: 1111512016 INTERIORNTE, M1 WiNDOWS AND DOORS, LLC 650 W. MARKET ST. iiIIIII111t1 o R - L o GRATZ, PA 17030 10 WOOD 10 S S OR SCREW SELF DRILLING SERIES 185 ALUMINUM FIXED WINDOW 0 1'r SCREWS 73" X 72" NON —IMPACT XWOODFRAMING OR 2X BUCK EXTERIOR METAL EXTERIOR FLANGE INSTALLATION DETAILS WITH RIGID FILLERS c rzTAT OF BY OTHERS ABACKER ROD & STRUCTURE BY OTHERS BACKER ROD & DRAWN- DWG NO. RD 08-02357 B ORX0' APPROVED SEALANT APPROV ED SEAL -ANT BEHIND FLANGE BEHIND FLANGE 1E NTS I DATE 09/03/14 STIEET 10 12 JAMB INSTALLATION DETAIL JAMB INSTALLATION DETAIL OF L. ROBERTO LOMAS P.E. 1 Luis R. Lomas P.E. WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE INSTALLATION 1432 WOODFORD RD LEWISVILLE, NC 27023 I'L No.; 62514 434-688-0609 rIIarnas@IrIoma9pe.WM REVISIONS 2 1/2" MIN. REV A DESCRIPTION REVISED INSTALLATION DETAILS DATE 06/01/15 APPROVED R.L. EDGE DISTANCE 8 REVISED NAME AND ADDRESS CONCRETE/MASONRY BY OTHERS 1 1/4" MIN. 14. 1 1/4" MIN. EMBEDMENT OPTIONAL 1X BUCK EMBEDMENT SEE NOTES 3 — 7 SHEET 1 CONCRETE/MASONRY BACKER ROD & 1/4 MAX. BY OTHERS 1/4" MAX. APPROVED SEALANT SHIM SPACE SHIM SPACE BEHIND FLANGE OPTIONAL IX BUCK RIGID FILLER SEE NOTES 3 — 7 SHEET I RIGID FILLER 3/16" TAPCON EXTERIOR INTERIOR 3/16" TAPCON INTERIOR 3/16" TAPCON BACKER ROD & APPROVED SEALANT RIGID FILLER BEHIND FLANGE 1/4" MAX. 2 1/2" OPTIONAL 1X BUCK SHIM SPACE MIN SEE NOTE 3 — 7 EDGE SHEET I DISTANCE EXTERIOR CONCRETE/MASONRY 1 BACKER ROD & BY OTHERS 1 1/4 MIN. APPROVED SEALANT EMBEDMENT BEHIND FLANGE JAMB INSTALLATION DETAIL CONCRETEIMASONRY INSTALLATION 2 1/2" MIN. EDGE DISTANCE VERTICAL GROSS SECTION CONCRETEIMASONRYINSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS WITH RIGID FILLERS DRAWN: DWG NO. — 02357 REV j . L. 08 B SCALE NTS JDATE 09/03/14 1 SHEET 11 OF 12 L. ROBERTO LOMAS P. E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rflomsLairlomaspe.com SIGNED: 1111512016 lk L 0 Q E N 0 61 TAT: OF 0 ORI Lp Luis R. Lomas P.E. FL No.: 62514 APPROVED SEALANT BEHIND FIN 6 WOOD SCREW 3/8" MIN _j EDGE DISTANCE EXTERIOR 1 1/4" MIN. EMBEDMENT WOOD FRAMING BY OTHERS Z6 r 1/4" MAX. SHIM SPACE INTERIOR 1/4" MAX F SHIM SPACE 3/8" MIN j EDGE DISTANCE 7 6 WOOD WOOD SCREW FRAMING 1 1/4" MIN. BY OTHERS SEALANT EMBEDMENT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION REVISIONS REV DESCRIPTION DATE A REVISED NSTALLAT10N DETAILS 06/01/15 E3 REVISED NAME AND ADDRESS 10/27/16 1/4" MAX WOOD FRAMING SHIM SPACE BY OTHERS 6 WOOD INTERIORSCREW 1 1/4" MIN. EMBEDMENT T- NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, APPROVED NOT SHOWN FOR CLARITY. SEALANT 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE BEHINC/FIN DESIGNED IN A CCORDANCE WITH A STM E2112 EXTERIOR I , MIN EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ PA 17030 r R. Lo 4tplll Lp 45 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON—iMPACT FIN INSTALLATION DETAILS TAT9 OF 0 RVD"I'- 1 . Q, ONAt 6111111100\ DRAWN: L. DWG NO. 08—.02357 REV B_ LE NTS DATE 09/03/14 1 SHEET 12 OF 12 L, ROBERTO LOMA P. E. 1432 WOODFORD RD LEWISVILLE, IVC 27023 434-688-0609 r1lomas@)Irlomaspe.com Luis R. Lomas P.E. FL No.: 62514 Florida Building Code Online Pace 1 of 3C NMI 0 J— 4. t7 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search dopr.N.Product ApprovalUSER: Public User Product Approval Menu > Product or Agglicadon Search > Aj)plication Lis Application Detail FL # FL15353-P,3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered ; Architect or a Licensed Florida Professional Engineer E' Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Luis R Lomas, PE the Evaluation Report Florida License PE-62514 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Steven M. Urich, PE R6 , Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method FL15353 P.3 COI FLCOI.pd Standard AAMA 450 Method I Option D Year 2010 https://www.tloridabuilding.ora/pr/pr app dtl.aspx?param=wGEVXQmqDqtH8572qvdWIS... 2/1/2018 Florida Building Code Oriline, Page 2 of 3 Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products 10/16/2017 10/23/2017 10/26/2017 12/12/2017 I FL # L!-c!10, Number or Name Description 15353.1 5764 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01448B,r)d Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512072B,od span: 104-1/4'. 1 Created by Independent Third Party: Yes 1 15353.2 15764 1 Vertical Aluminum Mullion I Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01439B.pd Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512063B.[)d span: 83" Created by Independent Third Party: Yes 1 15353.3 15765 1 Horizontal Aluminum Mullion I Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01449B.pd Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512073B.Ipd span: 156-3/8" Created by Independent Third Party: Yes 115353.4 1 S765 I Vertical Aluminum Mullion I Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01440B.i)d Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512064B.pd span: 83". Created by Independent Third Party: Yes 115353.5 1 CM-18514 I Vertical Aluminum Mullion I Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-014426.1)d Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE S12066B.Ipd length - 83". Created by Independent Third Party: Yes 115353.6 1 CM-18520 I Horizontal Aluminum Mullion I Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 11 08-01451B.r)d Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL15353 R3 AE 5120758.[)d span - 156-3/8" Created by Independent Third Party: Yes 115353.7 1 CM-18523 I Horizontal Aluminum Mullion I Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 11 08-01452B.I)d Approved for use outside HVHZ: Yes,.. Verified By: Luis P. Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL15353 R3 AE 512076B.lDd span - 104-1/4". Created by Independent Third Party: Yes 1 15353.8 1 CM-18531 I Vertical Aluminum Mullion I Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Installation Instructions FL15353 R3 II 08-01443B.I)d Verified By: Luis R Lomas, PE PE-62514 https://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wGEVXQwtDqtH8572qvdWlS... 2/l/2018 Florida Building Code Online Page 3 of 3 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512067B.Od span - 83" Created by Independent Third Party: Yes 15353.9 CM-18532 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 11 08-01453B.j)d Approved for use outside HVHZ: Yes Verified By: Luis-R Lomas, FE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL153S3 R3 AE 512077B.[)d span - 156-3/8" Created by Independent Third Party: Yes fCM--1853315353.10 Verti-1 Al,,m,,,.m Mullion Limits of Use Installation Instructions Approved for use in HVHZ:-No FL15353 R3 II 08-01444B.Dd Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512068B.r)d span: 83" Created by Independent Third Party: Yes 15353.11 CM-18534 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01454B.pd Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other. Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 5L20Z8B.pff span: 156-3/8". Created by Independent Third Party: Yes F. _-_ IF, _-_ti Contact U :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone, 850-487-182 The State of Florida is an WEED employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.467.1395. -Pursuant to Section 45S.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: L r "M https://www.floridabuilding.orc,lprl'pr—app_dtl.aspx?param=wGEVXQwtDqtH8572qvdWIS... 2/l/2018 NOTES: 1 ) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO MULLPON, WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI WINDOWS AND DOORS, INC. 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW OR DOOR UNIT. 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. 9) MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED ANO MULLION 15 ANCHORED ACCORDING TO THIS DOCUMENT. DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16- 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN[ AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH — Wl I W 212 REVISIONS DESCRIPTION -E I _pRol". ED INSTALLATION DETAILS 06/10/15 R.L. HORING NOTES & INSTIL DET. 06/07/17 R.L. ANCHORING NOTES: 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIE NT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 2) FOR ANCHORING INTO CONCRETE USE 1/4" ELCO ULTRCON TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT WITH I" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 3) FOR ANCHORING INTO METAL USE #10 SMS OR SELF DRILLING SCREW WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 4) ALL FASTENERS TO BE CORROSION RESISTANT. 5) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. --WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. C. MASONRY STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). D. METAL STRUCTURE —STEEL 18CA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063—T5 FU=30KSI .062" THICK MINIMUM. 6) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS 6" FROM EACH MULLION END AND 12" MAX. D.C. THEREAFTER. STAGGER SCREWS AT EACH WINDOW. TABLE OF CONTENTS SHEET NO. DESCRIPTION I NOTES 2 CONFIGURATIONS AND DP CHART 3 INSTALLATION DETAILS 4 COMPONENTS MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 — VERTICAL MULLION 83" MULLION SPAN GENERAL NOTES DRAWN: DWG NO, V. L. 08-01439 SCALE NTS _TllAlE 011/11/12 SHIU 1 OF 4 L. ROBERTO LOMAS RE t432 WOODFORD RD LEWISVILLE, NC27023 434-688-0609 r1lomasciDIrloo7aspo.com SIGNED: 1011312017 ox 111111/1// . R L 0 N cEN -y p 0. OF .,4u::- At' 6 R ll t NR ] B 61 G Luis R. Lomas P.E. FIL NO.: 62514 r 107 3/8" OMBIN6 WIDTH Wl T-- 133" FRAME HEIGHT WINDOW WINDOW MULLION SPAN) I I 107 3/8" OMBINED WIDTH-[ T Wl W2 83" IWINDOWFRAME HEIGHT WINDOW MULLION SPAN) 7 L1111 107 3/8" COMBINED WIDTH F_ W1 W2 83" WINDOW FRAME HEIGHT WINDOA WINDOK MULLION SPAN) LL L W1 COMBINED W2 107 3/8' LTH Design pressure ratinq so Mullion span (in) Tributary width n) 18.13 25.50 36.00 42.00 48.00 52.13 25.00 120.0 120.0 120.0 120.0 120.0 120.0 37.38 i2b.b 120.0 120.0 120.0 120.0 120.0 49.63 120.0 98.3 81.2 76.9 75.2 75.1 62.00 71.0 52.2 39.7 35.9 33.4 32.3 65.63 59.6 43.7 33.0 29.6 27.4 26.3 2 6061 4.1 32.7 24.4 21.B 19.0 19.0 tI 8.1 20.3 I - I - LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT INCLUDE FLANGE. 107 3/8" OMBINED WIDTH-[ T Wl W2 83" LOWFRAME 4NDOW HEIGHT MULLION SPAN) 107 3/8'. COMBINED WIDTHF_ Wl W2 T- 83" WINDOW FRAME HEIGHT WINDOW WINDOW MULLION SPAIN) L W 1 COMBINED W2 107 3/8" WIDTH REVISIONS I REV I DESCRIPTION I DATE I APPROVED I A REVISED INSTALLATION DETAILS 1 06/10/15 R.L. B REVISED ANCHORING NOTES & INSTL DET 1 065/07/17 R.L. 101 3/8'. COMBINED WIDTH F_ WI -1 [- W2 T-- 83" WINDOW FRAME HEIGHT WINDOW WINDOW MULLION SPAN) L WI W2 107 3/8" COMBINED WIDTH APPROVED CONFIGURATIONS MULTIPLE UNITS MAYBE MULLED TOGETHER AS LONG AS COMBINED WIDTH DOES NOT EXCEED 107 318"AS SHOWN HEREIN. Des yn pressure rating (pso with rebar Mullion span (in) Tributary width (in) F2--- 18.13 5.50 F3 6,00 42.00 48.00 52.13 25.00 120.0 120.0 120.0 120.0 120. D 120.0 37.38 120.0 120.0 120.0 120.0 1200 120.0 49.63 120.0 98.3 81.2 76.9 75.2 75.1 62.00 95.2 70.0 53.3 46.1 44.8 43.4 65.63 80.0 58.6 44.2 39.7 36.7 35.3 2, 00 0 3 43.9 32.8 29.2 26.7 25.5 4 .00 377 0 3 16 0 151 LARGE AND SMALL MISSILE IMPA C T, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHARTARE FRAME DIMENSIONS AND DO NOT INCLUDEFLANGE. MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 - VERT:CAL MULLION 83" MULLON SPAN APPROVED CONFIGURATIONS AND RATING CHARTS IDRAWN: OWG NO. V. L. 08-01439 ISCALE NTS JDATE 01/11 /12 1 SHEET 2 OF 4 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rflomasL&Irfomaspexom SIGNED: 1011312017 P, L op o 51 TAT 0 Luis R. Lomas P. E. FL No.: 62514 I" MIN EDGE DISTANCE MASONRY/CONCRETE BY OTHERS 1 1/4" MIN. EMBEDMENT 1/4" ELCO ULTRACON TAPCON 5ECT5796 CLIP OPTIONAL REBAR F=-A MT000022 CLIP r 1 : # 10 woo Ir 1 318" EMBEDM W 1/2" MIN. 2 EDGE L B DISTANCE VERTICAL CROSS SECTION MASONRYICONCRETE AND WOOD FRAMING INSTALLATION NOTE: CLIPS MAY BE USED IN MASONRY/CONCRETE OR WOOD FRAMING SUBSTRATE. SECT5764 MULLION D SCREW MIN. ENT ODD FRAMING/ X BUCK Y OTHERS REVISIONS DESCRIPTION DATE PPROVED REVISED INSTALLATION DETAILS REVISED ANCHORING NOTES & INSTL DET. 06/07/17 R.L. MT000022 CLIP 10 SMS OR SELF DRILLING SCREW ETAL 1/2 RucTURE BY OTHERS MIN. L 'T EDGE DISTANCE VERTICAL CROSS SECTION METAL INSTALLATION MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 — VERTICAL MULLION 83" MULLION SPAN INSTALLATION DETAILS EDRAWN: — FD G NO - V. L. 1 08-01439 01/11/12 1 SHEET 3 OF 4 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NG 27023 434-6 88-0609 rltomas@lrtomaspe.com I&N SIGNED: 1011312017 0M, 9 Lo E IV o(p WtAR OF' FE—v B Luis R. Lomas P.E. FIL N 0 .: 62514 2.140" 1.125 I SECT5764 MULLION ALUMINUM 6005-T5.125"TI-IICK 1— 0.658" T 1.531" j RF-P ?EBAR 16 GA (062) GALVANIZED STEEL NOTES: 1. CLIPS MAY BE USED IN MASONRY/CONCRETE OR WOOD FRAMING SUBSTRATE. 2, FOR WOOD & METAL INSTALLATION USE ALL FOUR ANCHOR LOCATIONS. 3. FOR CONCRETE 1NSTALLATION USE 2 ANCHOR LOCATIONS ONLY WITH 3 1/4" SEPARATION BETWEEN ANCHORS. i 0.843" f-- 3.26 375" 0.6251, F 3.250" 4.000" 0 O_j MT000022 CLIP 16GA (063") GALVANIZED STEEL SEE NOTE 2 & 3, THIS SHEET. 3.750" — 2.189" — 1.0)0" J—I — 0.375" 0.843" T- 2X 00.210" 1.562" 1.562" 1 SECT5796 CLIP FOR WOOD FRAMING INSTALLATION ALUMINUM 6063-T5.125-THICK REVISIONS DESCRIPTION DATE REVISED INSTALLATION DETAILS 06/10/15 R. L. REVISED ANCHORING NOTES & INSTL DET. 06/07/17 R.L. 3.750" 1.0 0" 0,375" 0.4 2" 2.032" 2.875" O.B43" SECT5796 CLIP 2X 00.210" FOR CONCRETE INSTALLATION ALUMINUM 6063-T5.125"THICK MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 — VERT:CAL MULLION 83" MULLON SPAN COMPONENTS DRAWN: V.L. 08-01439 SCALE NTS JDAT' 01/11/12 1 SHEET 4 OF 4 t. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE. NC 27023 434-688-0609 rlIo—@W0.a5pe.c0. SIGNED: 1011312017 FL L 51 0 fc, -Z IONAL I Luis R. Lomas P.E. FIL No.: 62514 Florida Building Code Online Page 1 of 3 gU-1 -g SEEM BCIS Home Log In User Registration Hot Topics Submit Surcharge Stabs & Facts Publications FBC Staff BCIS Site Map Links Search d pr : 'Aali Product, Approval U ER: Pubic Userhie" - Product Approval Menu > Product or Application Search > Application Lis Application Detail FL # FL13223-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer James Hardie Building Products, Inc. Address/Phone/Email 26300 La Alameda Ste. 250 Mission Viejo, CA 92691 909) 349-2927 pingsheng.zhu@jameshardie.com Authorized Signature Pingsheng Zhu pingsheng.zhu@jameshardie.com Technical Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana, CA 92337 909) 349-2927 pingsheng.zhu@jameshardie.com Quality Assurance Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana, CA 92337 909) 349-2927 pingsheng.zhu@jameshardie.com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Ronald 1. Ogawa the Evaluation Report Florida License PE-24121 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By John Southard, P.E. 1-. Validation Checklist - Hardcopy Received Certificate of Independence FL13223 R4 COI Rio - Certificate of Indelpendence.r)df Referenced Standard and Year (of Standard) Standard ASTM C1186 ASTM E330 Year 2007 2002 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL13223 R4 Eouiv R10-2692B-17 ASTM C1186 equivalency.od http://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=wGEVXQwtDqvRk6bsvZ66FC... 2/6/2018 E Florida Building Code Online Page 2 of 3 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method I Option D 08/09/2017 08/25/2017 08/28/2017 10/10/2017 I FL # Model, Number or Name Description 13223.1 Cempanel Siding fiber -cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13223 R4 11 cempanel-installation.i)d Approved for use outside HVHZ: Yes FL13223 R4 II NOA 17-0406.06.pdf Impact Resistant: Yes fl-13223 R4 11 RIO 2689-17 Lqa_e_1ti;LF_Urrin_q_.Pff FL13223 R4 11 RIO-2686-17 Panel Wood Metal Frame.odDesignPressure: N/A Verified By: Ronald I. Ogawa 24121Other: For use inside a HVHZ install in accordance with NOA 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA_17-0406.06.pd FL13223 R4 AE RIO 2689-17 Panel to Furring.r)d FL13223 R4 AE RIO-2686-17 Panel Wood Metal Frame.Ddf Created by Independent Third Party: Yes 13223.2 HardiePanel Siding fiber -cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13223 R4 11 HardiePanel-Installation.ipdf Approved for use outside HVHZ: Yes FL13223 R4 II NOA 17-0406.06.i)df Impact Resistant: Yes FL13223 R4 II RIO 2689-17 Panel to FurrinQ,pd FL13223 R4 II RIO-2686-17 Panel Wood Metal FrarlDesignPressure: N/A Verified By: Ronald I. Ogawa 24121Other: For use inside a HVHZ install in accordance with NOA 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06.i)d FL13223 R4 AE RIO 2689-17 E Lnel to Furring-,Pff FL13223 R4 AE RIO-2686-17 Panel Wood Metal Frame,odf Created by Independent Third Party: Yes 13223.3 Panel Siding fiber -cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13223 R4 11 NOA 17-0406.06.pd Approved for use outside HVHZ: Yes ELI Z23 R4 II Prtv H-Panel-Installation.pffgL Impact Resistant: N/A Design Pressure: N/A FL13223 R4 II RIO 2689-17 Panel to Furrinq.[)df FL13223 R4 11 RIO-26S6-17 Panel Wood Metal Frame.pd Verified By: Ronald 1. Ogawa 24121Other: For use inside a HVHZ install in accordance with NOA 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06.[)d Q 2&Q9-17 Pantl_to F Lrno fFL13;LZ2_E_4_AE EIL FL13223 R4 AE RIO-2686-17 Panel Wood Metal Frame.Ddf Created by Independent Third Party: Yes Kick F-7e-t Contact U :: 2601 Blair Stone Road, Tallahassee FIL 32399 Phone, 850-487-182 The State of Florida is an WEED employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used 1`6 official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M cm M, ZR E http://v;,A,w.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvP,k6bsvZ66FC... 2/6/2018 Florida Buildinc, Code Online Pace 3 of 3 I t, De d,,, Card See i http://www.floridabuildinc,.orc,,/Pr/pi_app dtl.aspx?param=wGEVXQwtDqvRk6bsvZ66FC... 2/6/2018 Florida Product Approval HardleftnelO Siding For use inside HVHZ: o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami -Dade County Florida NOA 17- 0406.06. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. 0 For use outside of HVHZ, o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Reports RIO-2686-17 or RIO-2689-17. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. Hardie Pane VeitcalSiding JamesHardie INSTA.LIATION REQUIREMENTS RESIDENTIAL SINGLEFAIVIII Y ONLY - PRIMED & COLORPLUS"' PRODUCTS E - FE 'CTIVE SEPTEMBER 2013 Im for the most recent version. SMOOTH - CEDARMILLII' - SELECT SIERRA 8 - STUCCO IMPORTANT. FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPUGABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPUCATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY, BEFORE INSTALLAT10N, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS. INSTALLA11ON OF HZ1 OTM PRODUCTS OUTSIDE AN HZ1 0' ' LOCATION WILL VOID YOUR WARRANT TO DETERMINE WHICH HARDIEZONE APPLIES TO YOUR LOCATION, VISIT WWW.HARDIEZONE,COM OR CALL 1-866-942-734,3 (866 9HARDIE) STORAGE & HANDLING: Store flat and keep dry and covered prior to installation. Installing siding wet or saturated may result in shrinkage at butt joints, Carry planks on edge. Protect edges and corners from breakage, James Hardie is not responsible for damage caused by improper storage and handling of the product. -1,19 - _ - __ CUTTING INSTRUCTIONS OUTDOORS INDOORS Position cutfing station so that wind will blow dust away from LISPr 1, Cut only using qcnie and snip, or shears (manual, electric or pneumatic). aid others in workino area. 2, Position cutting station in well -ventilated area 2. Use one of the tollov,qng methods: a. Best: I. Sc.ye and snap ii, Shears (manual: electric or pneur atic) - NEVER use a power saw indoors b. Better: I. Dust reducing circular saw equipped with a - NEVER use a circular saw blade that does not carry the HardieBlade saw blade trademark HardieBlade saw blade and HEPA vacuum extraction NEVER dry sweep — Use wet suppression or HEPA Vacuum c. Good: I. Dust reducing circular saw with a HardieBlade saw blade only use for low to moderate cutting) Important Note: For maximum protection Owviest respirable dust production), James Hardierecommends always using "Best" -level cutting melliods; where feasible. NIOSH-approvel respirators can be used in conjunction withr above cutting practices to further reduce dust ewures. Additional exposure informabon is available at wivmrjameshardie.corn to halip you determine tie me, appropriate cutting method foryour job requirements, If concern still exists abourt eXPOSUre level,,; or you s,_ 31 oedonotcomplywiththeabovepractices, you si oulcl always consuft a qualffi d industrial hygianist or contact James Hardie for further information. ' - GENERAL REQUIREMENTS: These instructions to be used for residential single family installations only. For Commercial / Multi -Family installation requirement,, go to vvA,.JamesHard;,eCommercial.com HardiePaneP vertical siding can be installed over braced wood or steel studs spaced a maximum of 24" D.E. See genernal fastening requirements. Irregularities in framing and sheathing can mirror through the finished applicaton. James Hardie recommends installing HardiePanel on a capillary break (rainscreeniff6irring) as a best practice. Information on installing James Hardie products over foam can be located in JH Tech Bulletin 19 at wvkiv, ia miehardie.com A water -resistive barrier is required in accordance with local building code requirements, The water -resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration, James Hardie does manufacture HairdieWrap- Weather Barrier, a non -woven non -perforated housewrapl. which complies with building code requirements. When installing James Hardie procucts all clearance details in figs. 5,6,7 8,9,1 0&11 must be followed. Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minirnum of 6" in the first 10'. Do not install James Hardie products, such that they may remain in contact with standing water. HardiePanel vertical siding may be installed on vertical wall applications only. DO NOT use HardlePanel verti al siding in Fascia of- Trim applications. Some pplication are not suitable for ColorPlus. Refer to ColorPlus section page 3. DO NO I use stain, oil/al El base paint, or powder coating on James Hard I e't Products. For larger rOjE , 2ng commercial and multi-famiK, projects, where the span of the wall is significant in length, the designer and/or architect should take into consiT ration the coefficient of thermal expansion arid moisture movement of the product in their design. These values can be found in the Technical Bulletin 8 "Expansion Characteristics" at www.JamesHardie.com. INSTALLATION: Joint Treatment Fastener Requirements & Vertical Joints - Install panels in moderate contact (fig. 1), alternativelyPositionfasteners3/8" from panel edges and no closer than joints may also be covered with battens, PVC or metal jointers or2" away from corners. Do not nail into corners. caulked (Not applicable to ColorPluse Finish) (fig. 2). HardiePanel Vertical Siding Installation * Horizontal Joints - Provide Z-flashing at all horizontal joints (fig. 3). Framing must be provided at horizontal and vertical edges for nailing, Figure 2 Figure 3HardiePanelverticalsidingmustbejoinedonstud. water -resistive barrier water -resistive barrier Double stud may be required to maintain minimum edge 2 4 stud I d v1ratEtrarenailingdistances, 2 x 4 stud rsistive zl wattrepistive 1! artier i upper panel upper panel Figure 1 stud DO/ not 114" gap Do not 1./4` gain water-resi Stiv Caulk Uailk barrier I 2 11-hirtZ-flashingBattenJoint "H" Joint n nr, s sheathing HardiePanel dverticalsidingwater -resistive barrier keep nails 2 x 4 stud lower 3/8" min. 4 panel from panel allint or, g- d - ln low", elpanelUU, edges plat 0 0 Figure 4 leave appropiate gap between Recommendation: when panels, then caulk* installir virigSierra8'.0r, Caulk Joint a 60101 n Stud al pandmoderatecontact ( No applicable to CohiPlus" Finish) joints to avoid nailing 1keepfastan2" 'Apply ,,aulk in accorcance with cailk titrough grooves. c ' r: ei's i U away fron m , manufaf Uer s written application insttuctions, For additional information on HardieWraplt"' Weather Barrier, COnSUlf,lames; Hardie at 1-866-4Hardie ormuvol.hardietivrap.com WARNING: AVOID BREATHING SILICA DUST Iames Hardiel pmduas contain resoiralbe crystalline silica, which is known M the State of California to cause canrpr and is cons.cared by IARC and NOSH to be a cause of cancerfircm sorne occupational sources. Breatting xcessive amciriLs Of respirable A6 dust can a;sc cause 2 disabling and potentially fatal lun, disease called sil.cosis: and has been I:nk.ed with otnei diseases, Some. slicies sugges' smok.ng may increase these risks. During installation or handling: (1) work in outdoor areas with ample ventilation I erenot feasible, use a HiirdieBladel sav,- blade and disl reduc;ng circilar saw attached to a HEPA,.,Kuum, 2) use f bei cement shears for cutting or, w1h 3) war oth rs in t immediate area 4) wear 8 prooerly-fifter, 1410SH-ainforovail dust mask cir respirator (-.g. N-95) in accordance with applicable governmem regulevors and manufacturer instructinns V., further limitnIaihe resnj a ol e silica exposures, During clean-up: use IIEPA vacuums or we! deanur metriods - riever cl_, sweep. For urmar information, refer to our installation instructions and Material Safe), Data Snea'. ,ailable at www.pameshardrexorr or by calling 1-800-9. iARDI-, (1: -800-942-7343). FAILURE TO ADHERE TO OUR WARNINGS, MSDS; AND INSTALLATION INSTRUCT IONS MAY LEAC TO SERIOUS rERSONAL INjURY OR DEATH. HS1236-PI/3 11/13 CLEARANCES Install siding and trirri products in Maintain a minimum 1 " Maintain a rninimurn 1 2" clearance At the juncture of the roof and vertical Maintain a 1/4" compliance with local building code 2" clearance between between Jarnes Hardie products surfaces, flashing and counterflashing clearance between requirements for clearance between James Hardie' and decking material. shall be installed per the roofing manufacturer's instructions. Provide a the bottom of James Hardie products and the bottom edge of the siding and products and paths, Figure 7 minimum 1 "- 2" clearance between horizontal flashing. the adjacent finished grade. steps and driveways. I I the roofing and the bottom edge of the Do not caulk gao. Figure 5 stud concr tee 6" min. foundation Maintain a minimum 1 2' oap between gutter end caps and siding &trim. Figure 9 sidini gutter and end cap Do not bridge floors with HardiePanel"' siding. Hori2ontal joints should always be, created bet%,een floors (fig. 11 0), VvIater- Resistive Barrier Figure 10 Horizontal Trim Sheathing fascia HardiePanele BLOCKED PENETRATIONS Penetrations such as hose bibs and holes 1 i" or larger such as dryer vents should have a block of trim around point of penetration. siding and trim. Figure 8 1 2" min. ftnhirg Refer to fig. 3 on page 1. KICKOUT FLASHING Because of the volume of water that can pour down a sloped roof, one of the rnost critical -lashing details occurs where a Framing roof intersects a sidewall. T e roof must be flashed withstep Flooring flashing, Where the roof terminates, install a kickout to deflect water away from the siding, It is best to install a self-achering nembrane on the wall before the subfasca and trim boards are nailed in place, and then come back to install the kickout. Figure 11, Kickout Flashing To prevent water frorn durnping behind the siding and the end of the roof intersection, install a "kickout" as required by IRC code R905.2.8.3 : "...flashing shall be a min. of 4" high and 4" wide." James Hardie recommends the kickout be angled between 00' - 1101 to maximize water deflection GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Flectro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot -dipped galvanized nails, James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie produms near the ocean, large bodies of water, or in very humid climates, Consult applicable product evaluation or listing for correct fastener type and placernent to achieve specific design wind loads. NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction, Consult James Hardie Technical Services if you are unsure of, applicable compliance documentation. Drive fasteners perpendicular to siding and framing, Fastener heads should fit snug against siding (no air space), (fig. A) Do not over -drive nail heads or drive nails at an angle. If nail is countersunk, fill nail hole and add a nail. (fig. B) For wood framing, under driven nails should be hit flush to the plank with a hammer (for steel framing, remove and replace nail). NOTE: Whenever a structural member is present, HardiePlank should be fastened with even spacing to the structural member The tables allokiving direct to OSB orplywood should only be used when traditional framing is not available. Do not use aluminum fasteners, staples, or clipped head nails. Snug Flush 57q 1T, Countersunk, fill & add nail do not under 00 NOT Figure A Figure B drive nails STAPLE Figure 11 Self-acheri n miembrarie 0eavesperrorane, mernbrane D,.p edge Hw T PNEUMATIC FASTENING James Hardie products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachment on the pneumatic tool is recommended. This will help control the depth the nail is driven, If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive under driven nails snug with ., smooth faced harnmer - Does not apply for installation to steel framing). HS1236 - P213 8113 CLEARANCES Install siding and trim products in Maintain a minimum 1 " Maintain a rninimum 1 2" clearance At the - uncture of the roof and vertical Maintain a 1/4" compliance with local building code 2" clearance between between Jannes Hardie products surflaces, flashing arid counterflashing clearance between requirements for clearance between James Hardie' and decking material. shall be installed per the roofing manufacturer's instructions, Provide a the bottom of James Hardie p, roducts and the bottom edge of the siding and products and paths, Figure 7 minimum 1 "- 2" clearance between horizontal flashing. the adjacent finished grade. steps and driveways. the roofing and the bottom edge of the Do not caulk gap. Figure 5 stud Figure 6 siding 1'1 11b.ritrler T siding and trim. Figure,8 Refer to fig, 3 on page 1. siding 71Zr_ r7,77 7MUT777M, 11"-2 min. bottom, A — concrete 6" min. foundation Maintain a minimum 1 gap between gutter end caps and siding & trim. Figure 9 sidin gutter anci end cap I!V-2"Ahrilll; deck material joist 2" Do not bridge floors with HaidiePariellsiding. Horizontal joints should always be created between floors (fig, 10). Water- ' Framing Resistive Berner Figure 10 Horizontal ' AL Flooring Trim Sheathing fascia HardiePanelO BLOCKED PENETRATIONS Penetrations such as hose bibs and holes 1 Y2` or larger such as drver vents should have a block of trim around point of penetration, GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot -dipped galvanized nails. James Hai -die is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie products near the ocean, large bodies of water, or in very humid climates. Consult applicable product evaluation or listing for correct fastener type and placement to achieve specific design wind loads. NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction, Consult James Hardie Technical Services if you are unsure o! applicable compliance documentation. Drive fasteners perpendicular to siding and framing. Fastener heads should fit snug against siding (no air space). (fig. A) Do not -over-drive nail heads or drive nails at an angle, If nail is countersunk; fill nail hole arid add a nail. ifig. B) For wood framing, under driven nails should be hit flush to the plank with a hammer (for steel framing, remove and replace nail). NOTE: Whenever a structural member is * o!esent, HardiePlank should be fastened with ever, spacing to the structural member. The tables allowing direct to OSB orplywood should only be used when traditional framing is not available. Do not use aluminum fasteners, staples, or clipped head nails. Snug Flush f =1 Countersunk, fill & add nail Figure A Figure B do not under drive nails DO NOTSTAPLE KICKOUT FLASHING Because of the volume of water that can pour down a sloped roof, one of the most critical 'lashing details occurs where a roof intersects a sidewall. The roof must be flashed with step flashing. Where the roof terminates, install a kickout to deflect water away from the siding. It is best to install a self -adhering membrane on the wall belore the subfascia and'trim boards are nailed in place, arid then corne back to install the kickout. Figure 11, Kickout Flashing To prevent water frorn dumping behind the siding and the end of the roof intersection, install a "kickeut" as required by IRC code R905.2.8.3 : "...flashing shall be a min. of 41' high and 4" wide." James Hardie recommends the kickout be angled between ': 00' - 110' to maximize water deflection Figure 11 Step flasi nq Self-achmnmembrane 9 Drip edge House Tap PNEUMATIC FASTENING James Hardie products can be hand nailed orfastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachmeni on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth o! oves diff icult, choose a setting that under drives the nail, Prive under driven nails snug with a smooth faced hammer - Does not apply for installation to steel framing). HS1236-P2/3 8/13 j Hardie Pan el'"'Z_Ia, VefticalSiding INSTALLATION REQUIREMENTS RESIDEENTIL SINGLEFAMEYONLY - PRIMED & COLORPLUS8 PRODUCTS JamesHardie EFFECTIVE SEPTEMBER 2013 M Visit forthe most ecentversion. SMOOTH - CEDARMILL@ - SELECT SIERRA 8 - STUCCO IMPORTANT. FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY. AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY. BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS. INSTALLATION OF HZ1 OTM PRODUCTS OUTSIDE AN HZ1 01' LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONE APPLIES TO YOUR LOCATION, VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343 (866 9HARDIE) STORAGE & HANDLING: Store flat and keep dry and covered prior to installation. Installing siding wet or saturated may result in shrinkage at butt joints. Carry planks on edge, Protect edges and corners from breakage. James Hardie is not responsible for damage caused by improper storage and handling of the product. L CUTTING INSTRUCTIONS OUTDOORS INDOORS Positicil cuttfirgi station so that wind will blow dust away from user 1. Cut only using scoie and snip, or shears (manual, electric or pneumatic). and others in working area. 2. Position cutting station in well -ventilated area 2. Use one of the tollcriving methods: a. Best: i Score and snap ii. Shears (manual, electric or pneurnafic) - NRIER use a power saw indoors b. Better: I. Dust reducing circular saw equipped with a - NEVPER use a cii cular- saw blade 11hat does not can-, the HardieBlade saw blade trademark HardieBladel saw blade and HFPA vacuum extraction NEVER dry sweep - Use wet suppression or HEPA Vacuum c. Good: i. Dust reducing circular saw with a HardieBlade saw blade only use for lom, to moderate cutting) Important Note: For maximum rflotection iJoluest respirable dust rpvocluction), James Hardie recommends always using "Best"-Ievel cutting methods where feasible. NIOSH-approv-11 respirators can be used Ili conjuncilion w ii. above cutting practces to furhei reduce dust eXPOSUi es. Additional exposui e information is available atmv,uJameshardie.rom to help you deter ir, themostapprolodater fling method foryour job requirements. 4 concern still.exists about exposure levels or youMileU do not comply with the above practices, you should always consult a qualified industrial hygienist or contact James Hardie for further information, S-12 3i 05 GENERAL REQUIREMENTS: These instructions to be used forresidential single family installations only. For Commercial / Mufti -Family installation requirements go to vwAi.jamesHard;IeCommercial.com HardiePanell vei tical siding Carl be installed over bracedi.,vood or steel studs spaced a maximum of 24" o.c. See genemal fastening requirements. Irregularities in framing and sheathing can mirror through the finished application. James Hardie recommends installing HardePanel on a capillary break (ranscreenturring) as a best practice. Information on installing James Hardie products over foam can be located in JH Tech Bulletin 19 at www. arnehardie.com A water -resistive barrier is required in accordance with local building ccode requirements. The water -resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration. Jarnes Hardie does manufacture HarcieWr pi- WeatrIer Barrier, a non -woven non -perforated housewrap-, which complies with building code requirements. When installing James Hardie products all clearance details in figs. 5,6,7,8,9,10&11 must be followed. Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minimum of 6" Ili the first 10'. Do not, install James Hardie products, such that they may rernain in contam with standing water. HardiePanel vertical siding may be installed on vertical wall applications only. DO NOT use HardiePanel vertical siding in Fascia or Trim applications. Some application are not suitable for ColorPlus, Refer to ColorPlus sec-lon p - age 3. DO NO- use stain. oil,lal d base paint, or powder coating on James Hardie"' Products. For larger rojE , Zg commercial and multi -family projects, where the span of the wall is significant in length, the designer and/or architect should take into consiTc ration the coefficient of thermal ex ansion arid moisture movement of the product in their design. These values can be found in the Technical Bulletin 8 "Expansion Characteristics" at mkim.JameNardie.com. INSTALLATION: Joint Treatment Fastener Requirements - Vertical Joints - Install panels in moderate contact (fig. 1), alternativelyPositionfasteners3/8" from panel edges and no closer than joints may also be covered with battens, PVC or metal jointers or2" away from corners. Do not nail into corners. caulked (Not applicable to ColorPluse Finish) (fig. 2). HardiePanel Vertical Siding Installation * Horizontal Joints - Provide Z-flashing at all horizontal joints (fig. 30). Framing must be provided at horizontal and vertical edges for nailing. Figure 2 Figure 3 HardiePanel vertical siding must be joined on stud. water -resistive barrier water -resistive barrier vatar-repistlile tive111wat%;opisDoublestudmayberequiredtomaintainminimumedge24stud2x4stud -o barrier riffnailingdistances. r —el Figure 1 stud UPI, 11 Do not 114" gap upper page o not 1.14" gap water -resistive Caulk ilk barrier sheathing HardiePanel Batten Joint "H" Joint Z-flashing Fi 2-tlash! no t vertioalsiding water -resistive barrier deroratry 2 x 4 stud bana hoard keep nails lower lower 3/8" min, panel from netpa edges f Palle[ platZq 0 C leave appropriate gap between Recommendation: when Figure 4 y 3/8" panels, then caulk' installing Sierra ,, p1svioc: C) moderate contact Caulk Joint ItNot applicable to Colo! Plus" Finish) a onublo stud at pancl join't's, to avoid rialir keep fasteZrsr 2" Apply caulk in accordance with caulk nrough grooves, away from c. scriners manufacturer s written application instructions. For additional information on. HardieWrap"' Weather Barrier, consult James Hardie at 1 -866-4Harde or wo.w.hardiewrap.com WARNING: AVOID BREATHING SILICA DUST larnes Hardie' Products contain respirable crystalline silica, mhi ti is knoiantf, the Sate of California to cause cancer and is considered try IARCC and NIOSH io be a cause of cancer from some occupational sources. Breathing eNss: anoints o' respirable silica dist can also ^cause a disabling and pntentiallv fatal lung disease calied sillclasis, and has been linked with offal diseases. Sonre studies suggest smolking may increasemese risks. Dunrigive installation or handling: ,1) v vlk in outdoor areas with ample ventilation: 110) use fiber cement shears for aming c.,, mnerenot feasible, use a Hardia-Blada* saw race aid dusti-reducing circular saw attached to a HEPA vacuum, 13) .v2rn ct ers in the immediate area: (4l w8a- a p-rcoarly-fitted, NIOSH-appr ved dust mask or respirator (e.g. N-95' in a-rcordance with applicable government regulations aro manutactur0Li er instructions t, further limit Of -tallation instructions and Material Safety Data Sheet available atesoirablesilicaexposures. During clean-up, use HEPA vacuums or wet cleanur methods - never dry saeep. Fir ormation, refler to ou;, in, wA i.."amesl.lardie.corr.orby allingi-800-911.',..RDI-'(1-800-942-7343). `AJLUHE 70 ADHERE TO OUR WARNINGS, MSDS, AND INSTALLATION INSTRUCT IONS MAY LEAD TO SERIOUS PERSONAL INJURY ORDEATIH. H 1236-1`1/3 1/13 CAULKING For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTM C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note: OSI Quad as well as some other caulking manufacturers do not allow tooling. DO NOT aulk nail heads when using ColorPlus products, refer to the ColorPlus ouch -up section CUT EDGE TREATMENT PAINTING Caulk, paint or prime all field cut edges. DO NOT use stain, oil/alkyd base paint, or powder Coating on James Hardiec Products. James Hardie products James Hardie touch-up kits are required must be painted within 180 days for primed product and 90 days for unprimed. 100% acrylic topcoats are to touch-up ColorPlus products. recommended. Do not paint when wet. For application rates refer to paint manufacturers specifications. Back -rolling is recommended if the siding is sprayed. COLORPLUSO TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE Care should be taken when handling and cutting James Hardie®R ColorPlus@ products, During installation use a wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product, then rinse with a garden hose, Touch up nicks, scrapes and nail heads using the ColorPlus" Technology touch-up applicator Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with new HardiePanel', siding with ColorPlus Technology. Laminate sheet must be removed immediately after installation of each course. Terminate non -factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus'' product dealer. Treat all other non -factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up, will not be covered under the James Hardie ColorPlus Limited Finish Warranty. The following outlines the recommended applications for ColorPlus and Primed panels. Not all designs will be suitable for every application: Exposed fasteners or battens is the recommended application for ColorPlus panel products Do not use touch-up over fastener heads for smooth ColorPlus products - primed panel recommended For ColorPlus panel applications that require fasteners in the field, it is acceptable to use touch-up over fasteners for Cedarmill and Stucco panel only, but correct touch-up application is important. Some colors may show touch-up when applied.over fasteners. Trim is recommended to cover joints when appropriate. PAINTING JAMES HARDIEO SIDING AND TRIM PRODUCTS WITH COLORPLUS" TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: Ensure the surface is clean, dry, and free of any dust, dir1, or mildew Repriming is normally not necessary 100% aMIic topcoats are recommended DO NOT use stain, oil/alkyd base paint, or powder coating on James Hard!0' Products Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature RECOGNITION: In apoi dance with ICC-ES Evalua-M Relport ESR-;844, Hardief`an IS, vertical siding is recogni2ed as a suitable altematetothat specified in: the 20-36.2009, & 2-312 International Residential Code to, One -and Two-FarAy Dwellings and tlie 2036, 2009; & 2012 Internatimal Building Gode. Hai dieParel vertical siding is also iecogni2ed to?. application in the following: City of Los Angeles Research Relon No. 24862. State of Florida IsTing -L#889, Dade Cour., Flinda NOA No. 02-0729.02, U.S. Dept, of HUD Mater als Release 1263c. Texas Department of Insurance Product Evaluation EC tyI ! 1 -23, C of New York MEA 223 -93-ld, and Caliiorma DSA PA-01 9. These documents should also be consulted for additional in Orinalon concemino the suitabil;!,, if this product ior sidecific applicaVons. . 2,313 James Hardie Building Products. All rights reseRled. TM, SM, and 0 denote. trademarks or registaied trademarks of Additional Installation Information, James Hardiel ennology Limited Lf is a i egistered Warranties, and Warnings are available at trademark of James Hardie 71 echnology Limited. www.jameshardie-com [of] J a m e s'n'a r CH e HS1236-P3/3 6/13 w5 11 AwI ! Z_- 141—AMI-OADIE COUNTY w agawa ACCIRLDArD r L LABORATORY, ACCREDUED July 30. 20V Pingshend Zhd Plz . Product Compliance Engi neer James Hardie Building Products 1 b901 Elm Ave' Fontana; CA 92337 Re: NOA-17-0406.06 Relativeto FBC 2017 Project RIO-2679AAA 7 Dear Pingsheng-.: After review of the.2017 FBC, it is my opinion thatthe curren't:,NOA-17-040G.D6 isin compliance with the.2017 Florida OU-11dingCode- Referenced Staodards in the 2017' FBC.' 1" Wood: AVVC. NDS-2 015 & SDPWS-2015 2. Structural Loads: ASCEISEI-7-1 0 1. Concrete ACE,3.18-14 4. Masomy::TMS402 - 201151AC1530,i3lASCE-5-13 5. StructutaiSteet: AISC,360-10 (.Including manual of steel construction 2010 (14"' edition)) 6- Cold -formed Steel- AlSl . 100-1 , 2, 71 Aluminum AM.&I -2015 In addition., I am making the -following Stattmen.tof lndependence as requested: 1 Ronald Ogawi. does nothave nor does it intendto acquire oT will it acquire any financial interestin any company manufacturing Or distributing products for which evaluations are issrjed 2. Ronald Ogaviia is not o,ed, operated or corit(olect by any company manufacturling or distribut . ing I products ft ev . altiates or inspect. 3. Ronald Ojewa lnic.dms not have, nor Mill it acquire a financial int6rest-inany compan , y manufactu(ing or distributing,productsficir wNch reportsmairi beinOssued_ 4,, Rpnald 6gawa does n-ot have, nor will it nquire a financial inte I res: I I in any I Ot . her entity involved in tbe appr- oval process of the prodict. Should You, have any questions on.anything, plane b6fitactme. Sinperely, Ronald 1. Oaawa; P. R! Ogawa & Associates, Irtc. iAS La. boratory Approval,. TL 360 1AS Quality Control A e c A-A-705, g n y,. CR RC Approved Testing Laboratory.for Solar.Refl.ecta nc,e- and Ernissivity Stale of Florida Approved Validat6r and Third Party Qu I ali . ty Control Agency 714) 292-2602 r6nz@.riogavv,a.c6m CC- Rob -r:Oqawa. — Ri 09awa &Associates., Inc- e Karen Oqawa — RI OqaAfa & Associates, Inc. OBAO J SOA of: rL 0 R loN. Lab Address: I , 985 Sampson Avenue, Corona, CA 92879 a Phone (7`14) 321-4959 a Fax:(714) 908-181.5 a E-mail.'roperO,- riogaxa-corn Mailing Address: 16S35 Algonquin St. #443, Huntington Beach, CA P2649 * Phone (702.) 491 371 0 P - ax,(714) WS-4815 * E-mail: debbvZ lnrjaavii cam Engineering i Quality Control 9 Product Development *Inspections * Code. Consulting Expert Witness a Testing NM DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMM. STRATION DWISION NOTICE OF ACCEPTANCE (NOA) James Hardie Building Product, Inc. e5 10901 Elm Avenue Fontana, CA 92337 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 S W 26 Street Room 208 NEamL Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/econoiny SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section Tn Miami Dade County) and/or the AHJ (in areas other than Miam-i Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by NEami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: "Hardie", "Cem" and "Prevail" Planks and Panels Fiber Cement Siding and Soffit APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlank-, CemPlank Prevail Lap Siding-, HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets I through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I. 0gawa, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. 1ISSILE IMPACT RATING. Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, Plant City, Florida, and the following statements: "ASTM C 1186 Type A compliant" and "Miami -Dade County Product Control Approved" is to be located on each siding plank or panel and per FBC 1710.9.2 and 1710.9.3 on Soffit panels. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Isfiamii-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This NOA renews NOA # 15-0122.04 and consists of this page I and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. IOVW 14N` NOA No. 17-0406.06 Expiration Date: May 1, 2022 Approval Date: May 4, 2017 Page 1 James Hardie Budidin2 Products, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS "Submitted under A10A # 13-0311.07" 1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; C, HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets I through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I. 0gawa, P.E. B. TESTS "Subinitted under NOA # 13-0311.07" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of HardiePlank, HardieSoffit and HardiePanel, prepared by Intertek Testing Services NA LTD, Test Report No. 100733361COQ-004, dated 08/24/2012, with revision I dated 04/25/2013, signed and sealed by Rick Curkeet, P.E. Submitted under NOA 02-0729.02" Laboratory Report Test Date Sianature15 2. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves P.E. 3. ATI 16423-2 PA 202 & 203 03/18/96 A. N. Reeves P.E. 4. ATI 16423-3 PA 202 & 20' ) 03/18/96 A. N. Reeves P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS "Submitted under NOA # 15-0122.04" 1. Statement letter of code conformance to the 5' edition (2014) FBC issued by Ronald 1. Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald I-. 0gawa, P.E. Carlos M. Utrera, P.E. Product Control Examiner NOA No. 17-0406.06 Expiration Date: May 1, 2022 Approval Date: May 4, 2017 E - I PROD as corn Buildim N0A-N1 ALL LENGTH --------------- SEE paci:g at 16" O.C. DETAILAstudsllelrII pf M WALL A, HEI HT UCT RENEWED plying with the Florida I Code 17-0406.06 Expirati 05/011.022 By 8 LL—A Miarni-Datfe Product Control Ah on Fumift No It 7 ji 3 1 Nails at 16' O.Q. (typ.) 3/8" MihimUm Edge DiStancCl Sheathing fastener, as descdbed in Note I Panel fastener, as described in Note 2 HardiePatiel, Cernpanel, Prevail Panel Siding Water -resistive barrier per Floeida Building Code Section 1404.2 A 5/8" thick / 5 ply APA rated plywood sheathing fastened in accordanix vAth Florida Building Code Section 2322.3 2" X 4'8-P-F Wood Studs The wall and sofftt frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. 518" thick / 6 ply APA rated plywdod sheattling in acto(dance vMh Florida 23223 BuildIng Code Section It1_111,10 wat'- 6anirrpe,;F'1or[da Building Code Sle ofion 1404.2 T X 4' S-P-F Wood Studs HardiePanat, J Cernpanel, PrevWl Panel Siding PRO 2 KT - DO —CM P' MQ HardlePanelO, CemparielO, & Prevail(lb Panel siding materials are nonasbestm fiber-cearrient products tested in accordance with ASTM C1 186 Grade 11, Type A and meeting the requirements ofthe Florida Building Code. IMANELMERMN-5 Width Length Thickness 4' 8,9,10' 5116" PESIGN PREWMU4 11N-G Installation Design pressure Wood Studs -76 psf I mpact Resistant - Planks installed over 5/B" thick / 11 ply APA rated plywood sheathing KEA_Nr=L,. PREVAIL PANE L:LD N ISTALLATIONN QEjA,%$ tanM the manufaotureesAllinstallationshallbeconformancevMhthisNoticeofAccep da Building Code. installation recommendations, and the appFicable sections of the nori 01 Wood studs where HardiePanel, Cempanell, Prevail Pand Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.OA It be attatched to the studs InRote1] 518" thick 15 ply APA rated plywood sheathing sha accordance with Florida Building Code $action 2322.3. The siding panels shall be 'installed over 5/8" thick 16 ply APA rated plywood t;heathir)g suppOrtell by a minimum of 21,X,4!'S-P-F wood studs spaced a maximum Of 16'0.C. 0.09Z'shankLNote2] The siding panel fastener shall be a 2" long, O.n3" head diameter, diameter, corrosion resistant siding nall; the fasteners shall be spaced at V, O.C. at panel edges and intermediate studs; the fasteners shall be driven through the 5/8" thick 15 ply APA rated plywood sheathing into wood studs located at 16!'O.C. a minimum clearance of Z'fromFastenersshallhaveaminimumedgedistanceof318" and comers. HARDIEPANEL, CEMPANEL, PREVAIL PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 FSr-M NO— DVVG NO R v Fax 909-427- E: ii!"I A PNL.-PLK-SOFF Creator: E. Gonzale!:,: ISCALE 1/2. 11 011 Dat6:4/2412013 . FET I OF 12 Fa8tener Spacing per Florida Building Code.Sedon 2322.3 a A.-T. No %-01W= Z IJ Fastener 8paoing per Florida Building Code Section 2322.3 PRODUCT RENEWEDPRODUCTREVISM SS conyplying vvidl the fleri% as complying with the Florida Bandins CO& Building Code At"Vtw", No NOA-No. 17-0406.06 0101 1PWICZ 7 By 121 0: 8/0N Framing Z Sheathing NOMINAL 2" X 4" S-P-r WOOD STUDS 16" O.C. FASTENED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD AREWITH3-112!'16d COMMON MAILS (Z PER TOP AND NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) BOTTOM CONNECTION) THE WALL ANO SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE jHEATHA* NOMINAL 5/8" THICK/ 5 PLY APA RATED PLYWOOD HARDIEPANEL, CEMPANEL, PREVAIL PANEL SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA INSTALLATION DETAILS WOOD STUD CONSTRUCTION BUILDNG CODE: SECTION 2322.3 qL-kqQLN-Gi THE PANI L IS FASTEN ED WITH 2" LO NG, 0,223" HEAD James Hardie Building Products, Inc, DIAMETER, 0.092k' SHANK DIAMETER CORROSION 10901 Elm Avenue RES19TANT SIDING NAILS, PLACE NAILS 6" C.C. AT JAL, Fontana, CA 92337 PANEL EDGES AND INTERMEDIATE STUDS Phone: 909-35 300 siz DWG NO Fay !909-42-1-0634 PNL-PLK-SOFF Creatm E. Gonzales 50ALrz i 1()' Date: 4/24/2013 2 OF 12 I T WALL. HEIGFF WALL LENGTH Stud $pacing at 16" O.G. E3 I I I 1-9 s with Suride f affR -e7 011 0 N SEE DETAIL A r— N 5/8" thick 15 ply APA rated plywood sheathing fasteiied to metal studs as described in Note I PRODUCT DQS_QBnT1qN HardlePanelO, Gempanel@, & PI`eVai[§ Panel Siding materials are nonasbestos fiber -cement products tested in accordancj-- Mth ASTM C1 186 Grade 1(, Type A and meeting the requirenients of the Florida Building Code. water-resistivu Width Lengtfi Thickness No, 1 barrier per Florida 4t 8,9,101 5/161, Bullding Code N STAI E PF Section 1404.2 Installation Design Pressure 4 0 R 20ga, 1-5/8" X 1-6181, Metal Studs -104 psf tal C-Stud Impact Resistant — P ------ HardlePanel, Panel installed over 5/8" thick 15 ply N 13 Carnpanel, APA rated plywood sheathingPrevailPanel Nails at G" O.C. (typ.) 3/8" Minimum Edge Distance Siding Pl_PANE_(ZEIVIPANEL,eREVAIL PANEL SIDING INSIAA- LAIPRPEIAILAHAk All installation shall be done In conformance with this Notice of Acceptance, the ni8inufacturees QE-TAIL-A- installation recommendntions, and the applicable sections of the Plorlda - sullding code, Metal studs where HardiePanel, Cempanel, Prevail Panel Siding Will be installed shall be Sheathing fastener, as Ida Building Code and the requirements of thisdesignedbyanEngineerorArchitectpertheFlor described in Note 1. N.O.A_ t:;rr REV SED Note 115/8" thick / 5 ply APA rated plywood sheathing shall be attached to metal studs at Woo Yiw* Wi We Flovida at panel edges and all intermediate supports using a No.8-18, 0.315" head diameterx 1-1/4" long4"g CO& Panel fastener, as described In N;) Note 2 bugle head screw 1 *7 9 The .5iding panels shall be installed over 518" thick / 5 ply APA rated plywood sheathing supported by a minimum 20ga, Nominal M/8" X 1-518" Metal C-studs spaced a mayJmum of IS" O.C. X [Note P] The siding panel fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-5/8" HardjePane)S Siding long* ribbed bugle head screw (*or screw shall have at least 3 full threads penetrating.metal taming); the fasteners shall be spaced at 6!'O.C. at panel edges and intermediate studs,,the fasteners shall be driven through the 5/8" thick/ 5 pIyAPA rated plywood sheathing into metal Water -resistive barrier per studs located at 1V'O,G. Florida Building Code Section Fasteners shall have a minimum edge distance of 3f8" and a minimum clearance of 2" from 1404.2 comers, 6/8" thick / S ply APA rated PRODUCT RENEWE'D----- L plywood sheathing fastened as complying with the Florida to metal studs as described Building Code NOA-No. 17-0406.06 in Note 1. Expiration D,4teO5/0112022 209a, 3-/8" X 1 5/8" Metal C-StUd The wall and soffit frames are to be designed By— CM-4 by the Architect or Engineer of Record inMiami-olbaAe Product Control compliance with the Florida Building Code. Phone. Fax 909-427-0634 A Creator E. Gonzales HARDIEPANEL, CEMPANEL, PREVAIL PANEL INSTALLATION DETAILS METAL STUI) CONSTRUCTION James Hardie Building ProductZ, Inc. 10901 171m Avenue Fontana, CA 92337 DWG NO PNL-PLK-BOrF Date: 4124/2013 ISHEET 3 OF 12 I 6.001n. I -- PRODUCT RENEWED Ets complying with the Florida Building Code ROA-Ka. 17-0406.06 PRODUCTREVLSED 0 con*ft YMh the F%6& DjdWW8 CA& 7TEx*eion 019 1 *1146 n-rA, .2;;2a-a -,,. i; - T I p1twi.LCT IM ISED 40 vwj ying wid, FIM44A 14070 By O&JO f'Mx[WQNOMINAL 20 GAUGE 3-5/,13" X 1-5/8" STEEL STUDS 16" O.C. FASTENED WITH 5/8'WAFER HEAD SCREW$ (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE allEA-THIM(i - NOMINAL 518"THICK / 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6" OC AT PANEL EDGE$ AND ALL INTERMEDIATE SUPPORTS USING A NO 8-13, 0.315" HEAD DIAMETER X `1_1/4 LONG BUGLE HEADSCREW THE PANEL IS FASTENED VATH NO. 8-18,0.316'HEAD DIAME . TER X 1-5/8' LONG CORROSION RESISTANT RIBBED BUGLE HEkD SCREWS (SCREW $HALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING), pLACE SCREWS 6" O.C. AT PANEL EDGES AND INTP-RMED1ATE STUDS ciadding 6,001n. Framing tit No. IF FOR METAL AND WOOD, sTups, PROVISIONS FOR DIAPHRAGM AQ'TION AND GRAVITY LOAD ARENOTPARTOFTHISAPPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIEPANEL, CEMPANEL, PREVAIL PANEL INSTALLATION DUAILS M5TAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 Ihone; E)09-356-6300 SVE NO PNL-PLK-SOFF Fax 909-A27-0634 A Creator: . E. Gon=zales SCAU 11, = 1,41 Date: 4124/27()1371--HE 4 OF 12 1 Stud Spacing at 16" 0,C. T HEIGHT 3/4" Minimum Edge Distance ZF-Atlt-A 14'2/aEl PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 SEE FRQD1JcT DF-so—ORTUON LENGTH lDtTPJ L A HardlePlanklD . . CemplankO, & Prevalla Plank Lap Siding materials 518" thick 15 ply APA 3rL' nonastiestos f1ber-cement YI ----- - -- T ccordance withproductstestedinaratedpVmodASTMC1186Grade11, Type A and sheathing in accordance vAth meeting the requirements of the Florida Building Code Florida Building Code. Section 2322.3 PANEL D0& Width Length Thickness 7 barrier per Florida 5(j-1/20 12! 5/16" Building Code Section 14042 DESIGNLEIR-ESSURe-MINQCoo") 21, X 411 S-P-F InstallaVor) Design Pre sure Wood Studs -92 psfWoodStuds Sheathing fbstener, as described in Note I Lap Siding Impact Resistant - S100 planks Installed over 5/8" thick / 5 plyt Nails at Is" O.C. (typ') r- -MC-1-10 i-iWiall X 5/16" APA rated plywood sheathing thick starle strip Siding fastener, as described in Note 2 HardiePlank, Cemplank, Prevail Lap Siding rWater - resistive barder per Florida Building Code Section 1404.2- 59/8" Ithick '15 ply APA rated plywood sheathing fastened In a=rdanGe with Florida Building Code Section 2322.3 1 Expiration E)ateO!5/01/2022 2" X 4" S-P-F Wood Studs The wall and soffit frames are to be designed By by the Architect or Engineer of Record InMiami-bi)ijeProduci-Control cornpliancewith the Florida Building Code. I — H :p -&RL<,(ZEKEI-ANK PREVAII All installation shall be done in conforMance with this Notice of Acceptance, the manufac ure s Installation reoommendations, and the applicable sections of the Florida Building Code. Wood studs where Hardieplank, Cemplank, Prevail Lap Siding will be Installed shall be designed by gin Engineer or Architect per the Florida Building Code and the requirements of this KO -A- Note 115/811 thick 15 ply APA rated plywood sheathing shall be attached to the stuft in accordance k with Florida Building Code Section 2322.3. course of the well with 1-114" widePlanksshallbeappliedhorizontallycommencingfromthebottom laps at the top of the plank such that the exposure area of each plank 18:5 8-11N'verticaliY. Note 2] The siding fastener shall be a 2-1/2' long, 0.223" head diameter, O.OV'shank diameter, corro-sion-resistant siding nail; The siding is fastened . 8A/4" O.C. vertically and 19'0.C. horizontally; fasteners are driven into wood studs through 5/8" thick / 5 ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately 814' from the bottom edge of the overlapping plank. Vertical joints shalt be placed over studs. The planks shall be installed over 5/8" thick / 5 ply APA rated olywood sheathing supported by a minimum of 21IX4" S-P-F wood studs spaced a MaYlmum Of 16" C-C- Fasteners shall have a minimum edgo distance of:Yff'. HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, I no. 10901 Elm Avenue Fontana, CA 92337 fie: 90 . 9-356-6300 size FSCM NO DVvr, NO REV Fa>c 909-427-0634 PNL-PLK-SOFF Creator E. Gonzales SME 1/2" 1'-0" Date; 4/241 013 SHEET 5 OP 12 Fastener Spacing per Florid8 Building Code Section 2322.3 PRODUCT RENEWED as complying with the Florida Building Code 0-75in ---- - --- NOA-N I o. 17-0406.06 Expiration qqeO5/01/2022 By Miami-lYadfe Product Control PRODUCTREVLSED Complying with the fkwi& a ty-71 ding cod AL-mrbaniv 1,10 ByT7Miami adc Pro&-Ct ERAMING NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O,C, FASTENED WITH 3-112" 16d COMMON RAILS (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLJANCE WITH THE FLORIDA BUILDING CODE 9—RWTHNQ NOMINAL 518" THICK / 5 PLY APA RATED PLYWOOD SHEATHING FASTEN50 IN ACCORDANCE WITH FLORIDA BUILDING CODE SECTION 2322.3 PLANKS,OVERLAP 1-1/4' THE EXPOSURE IS!98-1/4" THE PLANKS ARE FACE NAILED WITH 2-11Z LONG, 0.223" HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION- RE81STANT SIDING NAILS,'PLACED 314- UP FROM THE BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION Fastener Spac ig per Florida Building bode Section 2322.3 in. OC---H / Cladding Praming Sheathing MODVC,r REVISM is C(M*Y" WM &C Flo" EhM-kEng Coft No. - 21 STATE OF ORI lot FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION A,49'd WOTOAD ARE NOT PART OF TH[S APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIEPLANK, CEMPIANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 Fay 9Q9-427-0634 I A I' , PNL-PLK-80 FF Creator: E. Gonzales ISME Dlte:-4 T4/201-3 ISHEET 6 Or 12 REV PRODI as comi Building NOA-No Expirati By MIWM 1-10 WALL HEIGHT i d -,.Ll- Stud Spacing at 16!'O,C. LENGTH D FT ------------- 4 n 4tm cow wi+'& timidoi 8 Cc& Kl- YU. Y S IAT OF 8/4' Minimum lFdge Distance Nails at IQ" O.C. (typ) Q-E!AIJL A Sheathing fastener, as described in Note I odm6sco& M. Siding fastener I as I described in Note 2 HardlePlank, CemplariR, Prevail Lap Siding Water-resl8tive barrier per Florida Building Code section 1404.2 5181, thick 5 ply APA rated ICT RENEWED plywood sheathing fastened. to lying with the Florida metal studs as described irl. Code 17-0406.06 Note 1 120ga, 3-5/8" X 1-5/8" Metal C-stud The wall and soffit framesare to be designed by the Architect or Engineer of Pecord in compliah Ice with the Florida Building Code. V IV AV. A- q jv I SEE PAQW-(1 t Ea-C-AllTP-T!S0JJl ETAIL A HardiePI9nk0,,CempIanI0, and 5/8" thick 15 ply APIA PrevaiM Plank Lap Siding materials rated plywood are nonasbestos fiber -cement sheathing lastened products tested in accordance with ASTM CI 1186 Grade 11, Type A andtometalstudsas meeting the requirements of thesrribedInNote1 Florida Building Cpdo. Water -resistive barrier per Florida PLA 14FLRKQL ,N OM Building Coder Width Length Thickness 7z Sectlort 1404.2 t 9-1/2" 12' 5/161, DESIGN PRESSU RE, RADN—Q Meta; CStud Installation Design Pressure r,erriplank, Metal Studs -92 psfkHardiePlank, C Prevail QTI Lap SidingT-1 Impact Resistant - 1-1/4"tall X 5118" Planks Installed over 518" thick 6 ply thick starter strip APA rated plywood sheathing ON DETAILS All installation shall be done in conformance with Ns Notice of Acceptance, the manufacturer's Installation recommendations, and the applicable sections of the Florida Building Code. Metal studs where HardlePlank, Cernplank, Prevail Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. Note 115/8" thick / 5 ply APA rated plywood sheathing shall be attached to metal studs at 6"or, at panel edges and all intermediate supports using a No.8-18, 0.315" head diameter x 1-1/4" long bugle head screw Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1 /4" wide laps at the top of the plank such that the exposure area of each plank Is --5 8-IM!'vertically. INote 2) The siding fastener shall be a minimum No. 8-18, 0,315" head diameter X 2-1/4" long* bugle head screw over metal studs (*or screw shall have at least 3 full threads penetrating metal framing); The siding is fastened f. 8-114" O.C. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 5/8" thick 15 plyAPA rated plywood sheathingjasteriers are placed in the overlapping area approximately 314* from the bottom edge of the ovLrlaping planIc Vertical joints shall be placed over studs. The planks shall be installed over 518!'thIck 15 ply APA rated plywood sheathing supported by a minimum 209a, Norrdnal 3-518" X 1-5/8" Metal C-studs spaced A maximurn of 16" O-C. Fasteners shall have a minimum edge distance of 3/8". Greator: E. Gonzales HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc, 10901 FJrn Avenue Fontana, CA 92337 ME FSOM NO SOALE 112" - V-0" PNL-PLK-S0Fl` Date: 4/2412013 1 SHEU 7 OF 12 6.00in. 116 in. OC Cl8dding 6-00in. Framing 6,00in.00 Sheathing PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 ...... 0.751n Expiration,r)ate 05/01 /2022 B, OGAMiami-lfbcfe Product Control REVISED to vamplyiu# With dic Fk611% yi"g -with the Florils f HwId" CO& 7 No By TATE OF iDa& Pro6va Control 0 N All-- NOMINAL 20 GAUGE 3-5/8" X 1-5/8" STEEL STUDS 16" O,C. FASTENED WITH 5/8" LONG RIBBED BUGLE HEAD SCRBNS (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOAD$) COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATH-ING NOMINAL 518" THICK / 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6" OC AT -PANEL EDGES AND ALL INTERMEDIATE SUPPORTS U8114G A NO.8-18, 0.315" HEAD DIA.METERX 1-1/4' LONG BUGLE. HARD112PLANK, CEMPLANK, PREVAIL LAP SIDING HEAD SCREW INSTALLATION DETAILS METAL STUD CONSTRUCTION jqLAQ_QIN13 9 PLANKS OVr=RLAP 1-1/4" THE EXPOSURE IS,'8-114` James Hardie Building Produats,.Inc. THE PLANKS ARE FASTENED WITH NO, 8&-18, 0.$15' 10901 Elm Avenue HEAD DIAMET5R X 2-1/4" LONG CORROSION- N9 Fontana, CA 92337 RESISTANT RIBBED BUGLE HEAD SCRr-_WS (SCREW Pho;: 909-356-6300 S1?E FSCM NO Wr No REV SHALL HAVE AT LEAST 3 FULL THREADS Fax 909-427-0634 A PWL-PLK-SOFr 1 PENETRATING THE METAL FRAMING), PLACED 3/4" UP I HEETFROMTHr: BOTTOM EDGE OF THE PLANK AT EACH SHEET 8OF12Creator: E. Gonzales SCALE Date, 412412013 STUD LOCATION LL LENGTH E G PT ON. SE AKRIM Stud Spacing at 16" O.C_ D ETA I L A Hardie8offitS) & CemsoffitO materials are 1 I nonasbestos fiber -cement products tested inB-4-- accordance with ASTM C1 186 Grade 11 'Ivne A WALL V, 3/8" Minimum Edge 0E1A[L,A_ PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Expirati: ige! OL55/00 -111/240022-24 By- I and meeting the requirements of the Florlda Building Code. V: SOF T AIIE q1l_0A5 2"X 4"S-P-F EEL_pj_ __N Width Length ThIcKness Wqod Studs 4 81 114, ql!StQNLPRE gL!JQRPL T 4.q HardieSofft installation Design Pressure cemsoffit -Wood Studs -70 psf Soffit fastener, as described in Note I HardleSoffit, Cemsofflit Minimum 2" X 4" S-P-F Wood Stud 6 The well and soffit frames are to be designed by the Architect or Engineer of Record In compliance with the Florida Building Code, No. 4)21 STATE OF 810NAL — H.A.RPM Q_EELT_'Z 9S_QF1EL1_J? ARRUNG-TAA 1j.AJJ MYET A W$ All Installation shall be done in conformance with this Notice of Acceptance, the manuftaturer's installation recommendations, and the applicable sections of the Florida Building Code. Wood studs where HardleSoffit, Cemsoffit will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.0-A. The soffit shall be installed over minimum 2"X4" S-P-F w000 studs spaced a maximum of 16" O.C' Note 11 The soffit fastener shall be a 2" long, 0.223" head diameter, 0.092" shank diameter, corrosion resistant siding nail; the fasteners shall be spaced at 4!'O.G. at panel edges and intermediate studs the fasteners shall be driven into wood studs located at 16" O'C Fasteners shal(have a minimum edge dietance of 3/a" and a minimum clearance of X'from corners. HARDIESOFFIT, CEMSCIFFIT PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardle Building Products, Inc- 10001 Elm Avenue Fontana, CA 92337 3hone; 909-356-6300 SIZE FSCM No Fax 909-427-0634 A Creator; E. Gonzales SCALE DM NO REV PNL-PLK-SOFF 1 1 Oate: 4124/2013 1 SHEET 9 OF 12 4.00in 16.00in Cladding Framing. PRODUCT RENEWED as complying with the Florida Building Code N OA-N o. 17-0406.06 Expiration DaleGS101/2022 By 4,00in Miami-1160 Product Control PRdAX-rREVISED PRODUCrRE%;11;ED 41 1 4 1 .. OGA coftoying WA &C nori& as oomoy* veiffi &C Fkwf& 77, B(fildlas Coft Ac=ep1ftVW Me a-03 No. STATE OF 310 FRAMN-0 NOMINAL 2" X,4?'S-P.F WOOD STUDS 16" 0,C. FASTENED WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE CONNFECTION) * NOT PART OF THIS APPROVAL (MUST PROVIDI ALTERNATE PROVISIONS FOR THESE LOADS) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE THE SOFFI . T IS FASTENED WITH T LONG, 0.223" HEAD HARDIESOFFIT, CEMSOFFIT PANEL DIAMETER, 0.092" SHANK DIAMETER, CORROSION INSTALLATION DETAILS WOOD STUD CONSTRUCTION 2 NAILS N'O.C. AT PANELRESISTANTSIDINGNAILS, PLAC EDGES AND INTERMEDIATE STUDS James Hardie BUIlding Products, Inc. 10901 Elm Avenue Fontana, CA 92337 Phone: 909-356--6300 size FSCM 140 DV& 140 Rev Fax 909427-06S4 A PNL-PLK-SOFFI -- I j Creator: E. Gonzales SCALF 11 0- Date: 4124/2013 SHEM' 10 OF 12 WALL 0GH T], WAI, I.ENGTH Stud Spacing -at 16" O.C. SEE I I DETA[ L A 318" Minimum PRODUCT RENEWED as complying with the Florida Building Code 1 NOA-Mo. 17-0406.06 Expiration D By Piami-Di4d i I i Distance 510112022 Nails at 6" O.C_ (typ.) t fastener, as ribed in Note I Ha rdi e3offit, Cem soffit 20ga, 3-5/8" 1-5/8" Metal C-stud The wall and soffit framesare to be designed by the Arch1tec;t or Engineer of Record in compliance with the Florida Building Code. Hardiesoffite & CemsoffitO materials are nonasbestos f1ber-cement products tested In 8coordance w1thASTM. C1186 Grade 11, Type A and meeting the requirements of the Florida Building Code. 20ga, 3-518"X 1-ffl,, Width Length Thickness Metal C-stud 8. 4- Eirdi-Sofft DE$iGN PREPSUR RAINjelCernsomt —0 Installation Design Pressure Metal studs _55b9L',, GA MODUCT REVLvXD 7Z REVLSED iz comoyips wim Ow Florida Al I _ Z FA "1044yhg; with the Filatift Bkilding CO& aswiM3 Cog* 0,0_111,e7 121VD. NSTATEOF 01- 5de Pmdett Cor0rol rftvArd cow All installation shall be done in conformance with this Notice of Accept eM6fh,u,f,acturer`s installation recornmend6tions, and the applicable sections of the Florida Building Code. Metal studs where HardleSoffit, Cemsoffit will be installed shall be designed byan Engineer or Architect per the Florida Building Code and the requirements of this N.O.A.' The soffit shall be installed over minimum 20ga, Nomlnal 3-5t8" X 1-5/8" Metal C-studs spacw a maximum of 16" O.C. Note 1] The soffit fastener shall be a minimum No. G-18, 0.315" head diameter X 1-1/4" long* ribbed bugle head screw (*or screw shall have at least 3 full threads penetrating metal framing);the fasteners shall be spaced at 6" O.C. at panel edges and Intermediate studs: the fasteners shall be driven Into metal studs located at 16" O.C. Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from comers. Creator F—Gonzales HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DETAILS METALSTUD CONSTRUCTION James Hardie Building ProduGts, Inc. 10901 Elm Avenue Fontana, CA 92337 IZE PSCM NO A ALE' 1/2 ;,..:j J."O., bm NO PNL-PLK-SOFF Date: 4124/2013 11 C)F- 12 Cladding FMmInq 6.00in. A— PRODUCT RENEWED pRODUCt REVISED aoyjq WiL4 dwrwi4t Mooect avAsw as complying with the Florida Building Code 980ding co4e A NO co=oymg wkb ft fWillm DandingCV& NOA-No. 17-0406.06 f%clf%ol 1"anollov AmcwtMeO NO d 6 C a , b, 7 Expivo P NW, Expiratio BY pfa&vtBy Miami-Afid fad-- f Product Control ink NOMINAL20 GAUGE 3-5/8" X 1-5/8" ST5EL STUDS 1611 O.C. FASTENED WITH 5/6"WAFER HEAD SCREWS (2 PER TOp FOR METALAND WOOD S7UDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE AND BOTTOM CONNECTION) - NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR E GINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE qLAL!-Q1lI9—Q . HARDIESOFFIT, CEMSO.FFIT PANEL THE SOFFIT IS FASTENED WITH NO. 8-18, 0.315" HEAD INSTALLATION D TAII,$ METAL STUID CONSTRUCTION DIAMETER Y 1-1/4'LONG CORROSION RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 James Hardie Building ProdUcts, Inc. FULL THREADS PENE ' TRATING THE METAL FRAMING), PLACE 10961 Elm Avenue SCREWS TO.C, AT PANEL EDGES AND INTERMEDIATE STUDS Fontana, CA 92337 Phone: 909-356:6300 SIZE Fs bwa NO RL: Fw< 909-427-0634 A PNL-PLK-SOFF. Cre8tor: F. Gonzales SOALS 1"= V-0" Data: 4124/2013 SHEE:T 12 01' 12 PROJECT RIO-2689-17 ENGINEERING EVALUATION REPORT FOR ATTACHING JAMES HARDIE@ BRAND FIBER -CEMENT PANELS TO WOOD FURRING SOLUTIONS JAMES HARDIE BUILDING PRODUCTS, INC. 10901 ELM AVENUE FONTANA, CA 92337 TABLE OF CONTENTS PAGE COVER PAGE I EVALUATION SUBJECT 2 EVALUATION SCOPE 2 EVALUATION PURPOSE 2 REFERENCE REPORTS 2 TEST RESULTS 2 TABLE 1A, RESULTS OF TRANSVERSE LOAD TESTING 2 TABLE I B, ANALYSIS OF ALLOWABLE LOAD FOR #8 SCREW AT 10" O.C. 2 JUSTIFICATION OF USING THE RESULTS ON LIGHT GAUGE STEEL FRAMING 2 DESIGN WIND LOAD PROCEDURES 3 TABLE 2, COEFFICIENTS AND CONSTANTS USED IN DETERMINING V AND p 4 TABLE 3, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE B 4 TABLE 4, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE C 4 TABLE 5, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE D 4 TABLE 6, ALLOWABLE WIND SPEED (MPH) FOR HARDIEPANEL SIDING 5-6 AS PRODUCT EVALUATOR, THE UNDERSIGNED CERTIFIES THAT THE LISTED PRODUCTS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE ASCE 7-10, THE 2017 FLORIDA BUILDING CODE, AND THE 2015 INTERNATIONAL BUILDING CODE. PREPARED BY: RONALD 1. OGAWA & ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX 110101fl- -- l" 0 X.13GAWq 4t FLOR, A WM RONALD 1. OGAWA ASSOCIATES. INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 M 714292-2602; (F) 714-847-4595 PROJECT: RIO-2689-17 EVALUATION SUBJECT HardiePanel@ Siding James Hiirdie Product Trade Names covered in this evaluation: HardiePanelID Siding, CempanelO Siding, Prevail- Panel Siding EVALUATION SCOPE: ASCE 7-10 2017 Flodda Building Code 2015 International Building Code 2015 International Residential Code JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com EVALUATION PURPOSE: This analysis is to determine the ma)dmum design 3-second gust wind speed to be resisted by an assembly of HardiePanel (Cempanel, Prevail Panel) siding fastened to wood furrings on eitherwood or metal framing with nails or screws. REFERENCE REPORTS: 1. Intertek Report 102024363COO-001A, Transverse load test on HardiePanel. TEST RESULTS: Table ia. Results of Transverse Load Testing Frame Fastener Ultimate Allowable Test Thickness Width Spacing Spacing Fastener Type Load Design Load 2 Report Number Agency in.) in.) Frame Type' in.) in-) and Dimensions PSF) PSF) Failure Mode 102024363COQ-ODIA Intertek 0.3125 48 2X4 wood stud, 3/4" thick by 16 6 No. 8 X 1,25" long X 0.323" HD 160.7 53.6 pull through /fracture3.5' wide SPF furring ribbed bugle head screws 102024363COQ-001A Intertek 0.3125 46 2X4 wood stud. 314* thick by 16 8 No. 8 X 1.25" long X 0.323'HD 1 31.4 43.8 pull through3.5" wide SPF furring ribbed bugle head screws 102024363COO-001A Intertek 0.3125 48 2X4 wood stud, 3/4' thick by 16 12 No. 8 X 1.25' long X 0.323' HD 106.1 35.4 pull through I 1 3.5' wide SPF furring ribbed bugle head screws 102024363COO-001A Intertek 0.3125 48 2X4 wood stud, 314' thick by 16 6 0.090" shank X 0.215" HD x 1.5, 147.6 49.2 pull through /fracture3.5" wide SPF furring long ring shank nail 102024363COO-001A Interiek 0.3125 48 2X4 wood stud, 314* thick by 24 8 No. B X 1.25' long X 0.323' HD 82.7 27.6 pull through /fracture3.5" wide SPF furring ribbed bugle head screws 1. All Tasieners were installed on Turring witnout penetration into ine Trarning memDers. 2. Allowable load is determined from ultimate load divided by a factor of safety of 3. 3. HardiePanel Siding complies with ASTM C1 186, Standard Specification for Grade 11, Type A Non -asbestos Fiber -Cement Flat Sheets - Table 1b. Analysis of Allowable Load for #8 Screw at 10" O.C. 8 Screw Spacing Fastener Spacing (in.) 8 12 10 Frame spacing (in.) 16 16 16 Fastener Tributary area (ft2) 0489 1.33 1.11 Allowable load (pst) 43aS 3544 38.8 Individual fastener load (lb.) 38.9 47.2 4341 I , rhe fastener load for #8 screw at I V D.C. was calculated as the average of the test results for 8" and 12" D.C. The allowable load for #8 screw at the spacing of 10" D.C. into furring can be calculated by interpolating the results of same fastener at 8" and 12" D.C., since both tests had same failure mode of fastener pull through from the panels. As shown in the table, the allowable load for #8 screws installed at 10" O.C. to wood furring is 38.8 psr. Justification of Using the Results on Light Gauge Steel Framing In the subject configurations, all fasteners were attached to furring only, so whether the furring is attached to wood or steel framing does not affect panels' transverse load capacity. It's the project engineers responsibility to ensure the furring attachment and framing memebers to have sufficient load capacifies. cjGAWA, Sk t. 0 F! 0 RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 926,49 T-) 714-292-2602-1 (F) 714-847-4595 PROJECT: RIO-2689-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com DESIGN WIND LOAD PROCEDURES: Fiber -cement siding transverse load capacity (wind load capacity) is determined via compliance testing to transverse load national test standards. Via the transverse load testing an allowable design load is determined based on a factor of safety of 3 applied to the ultimate test load. Equation 1, q,=0.0Q256'VK,'K,-V' frief. ASCE 7-10 equation 30.3-1) velocity pressure at height z K, velocity pressure exposure coefficient evaluated at height z K,, topographic factor Kd wind directionality factor V, basievond speed (3-second gust MPH) as determined from 2015 IBC Figures 1609.3(l),(2), or (3): ASCE 7.10 Figures 26.5-1A, 8, or C Equation Z V=V (ref 2015 IBC Section 1602.1 definitions) V , ultimate design wind speeds (3-second gust MPH) determined from 2015 IBC Figures 1609.3(l), (2), or (3); ASCE 7-10 Figures 26.5-1A, 8, or C Equation 3, p=V(GC,-GC,,) (ref. ASCE 7-10 equation 30.6-1) GCv product of external pressure coefficient and gust -effect factor GCO product of internal pressure coefficient and gust -effect factor p design pressure (PSF) for siding (allowable desgn ]Dad for siding) To determine design pressure, substitute q, into Equation 3, Equation 4, P=0.00256-K,'Kz-Kd'Vw(GCP-Gc i) Allowable Stress Design, ASCE 7-10 Section 2.4. 1, load combination 7 Equation 5, 0.6D , 0.6W fret. ASCE 7-10 section 2.4. 1, load combination 7) D deadload W windload To determine the Allowable Stress Design Pressure, apply the load factor for W (wind) from Equation 4 to p (design pressure) determined from equation 4 Equation 6, p— = 0-61N Equation 7, p_, = 0.6*(0.00256-K,'-K,'V'-(GC,-GCi)) Equation 7 is used to populate Table 3, 4, and 5. To determine the allowable ultimate basic wind speed for Hardie Siding in Table 6, solve Equation 7 for V., Equation 8, V = (p d/0.6*0.00256*K,*K*Kd*(GC,-GC i))5 Applicable to methods specified in Exceptions 1 through 3 of 2015 JBC Section 1609. 1. 1., to determine the allowable nominal design wmd speed (Vasd) for Hardie Siding in Table 6, apply the conversion formula below, Equation 9, V-d = V. (rLf. 2015 IBC Section 1609.3. 1) V, , Nominal design wind speed (3-second gust mph) fref. 2015 IBC Section 1602. 1) Of I I I / ll'fAfo" ii'll"\ (jCkAWA L 0 3 RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 T) 714-292-2602; (F) 714-847-4595 PROJECT: RID-2689-17 Table Z Coefficients and Constants used in Determining V and p, K Well Zone 5 Height (fl) Exp B Exp C D K. K GCP GCj 0-15 0.7 0.85 1.03 h-160 1 850.85 1-4 D.18 20 0.7 0.9 1 08 1 KKd50.85 1.4 0.18 25 0.7 0.94 1.12 1 0.85 1.4 0.18 30 0.7 0.98 1.16 1 0.85 1.4 0,18 35 0.73 1.01 1.19 1 0.85 1.4 0.18 40 0.76 1.04 1 - 22 1 45 0.785 1.065 245 1 85 1.4 0.18 50 0.81 1.09 27 1 0.85 1.4 0.18 55 1 . 29 0.85 1.4 0.18 60 0.85 1.13 1. 3 1 1 0.85 1.4 0.18 100 0.92 1.26 1.43 h>50 1 1 1 0.85 1 -1.8 1 0.18 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com Table 3, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category B, no Speed (3-second gust) 100 105 110 115 1 120 130 140 150 ISO 170 180 190 200 210 Height (ft) a B 9 8 B B B B a l? B B B 8 0-15 14.4 15.9 17.5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 20 159 17-5 19.1 20.8 24.4 28.3 32.5 370 41.7 45.8 52.1 57.8 63*7 25 14.4 15.9 17.5 19-1 20.8 24.4 28.3 32.5 37.0 41.7 46.13 52.1 57.8 63.7 30 14.4 15.9 17.5 19.1 20.8 24.4 28.3 3Z5 37.0 41.7 46.8 52.1 57.8 63.7 35 15.1 16.6 18.2 19.9 21.7 25.4 29.5 33.9 3&6 43.5 48.8 54.4 60.2 66.4 40 15.7 17.3 19.0 20.7 22.6 26.5 30.7 35.3 40.1 45 3 50.8 56.6 62.7 69.1 45 15 9 111-1 21.4 23.3 27.4 31.7 36.4 41.5 46.8 52.5 58.5 64.8 1.4 50 7jg 22 1 24.1 28.2 32.7 17.1 42.8 48.3 54.1 60.3 66.8 73.7 55 17.1 18.9 72O 3 22 6 24.7 2 g 6 38.5 43.8 49.5 55.5 61.8 9-3 -3 68.5 776. -1 75.5 7T-36017.5 19.3 21.2 23.2 2'5.2 2g 9 1 34 4 39.5 44.9 50.7 56.8 100 25.6 28.2 43.3 50.2 57.6 65.5 92.4 102.4 112.9 Table 4, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category C, nd Speed (3-second gust) 100 105 110 115 1 120 130 140 150 ' 160 170 ISO 190 200 210 Height (ft) C C C C C C C C C C C C C C 0-15 17.5 193 21.2 23.2 25-2 29.6 34.4 39.5 44.9 50-7 56.8 63.3 70.1 77.3 20 18.6 20.5 22.5 24.6 26.7 31.4 36.4 41.8 47.5 53.7 60.2 67.0 74.3 81.9 25 19.4 21.4 23.5 25.6 27.9 32.8 38.0 79.6 43.6_ 49.6 56.0 62.8 70.0 77.6 85.5 30 20.2 22.3 24.5 26.7 29.1 ZZ-3 45.5 51.8 58.4 65.5 73.0 80.2 89.2 35 20.8 23.0 25.2 27.6 30.0 35.2 40.8 46.9 53.3 60.2 67.5 75.2 83.3 91.9 40 21.5 23.7 26.b 28.4 30.9 36.3 42.0 48.3 54-9 62.0 69.5 77.4 85.8 94.6 45 22--0 24.2 26.6 29.1 31.6 1 -371 43.1 1 49.4 1 -56.2 1 -63.5 1 -71.2 1 -793 87.9 9&9 50 22.5 24.8 27.2 29.7 32.4 38.0 44.1 50.6 57.6 650 72 2 l 19-1 99.2 55 a-22.9-25.2 27.7 30-3 33.0 38.7 44.9 51.5 1 -58.6 66.2 1 _74 2 27 91.6 101.0 50 23.3 25.7 28.2 30.8 33.6 39.4 45.7 b2A 1 -59 1 1 -5/.4 1 -1b.t. B4.1 JJ.2 IUZ.d 100 32.6 35.9 39.4 1 -4'11 1 -469 5- - 1436 Table 5, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category D, nd Speed (3-second gust) 100 105 110 115 120 130 140 150 160 170 ISO 190 200 2 0 Height (ft) D D D 0 D D D 0 D D D D D D 0-15 21.2 23.4 25.7 28.1 30.6 35.9 41.6 47.8 54.4 61.4 68.8 767 85.0 93.7 20 223 24.6 27.0 29.5 32.1 37.7 43.7 50.1 57.0 64.4 72.2 80 4 89.1 98.2 25 23.1 25.5 28.0 30.6 33.3 39.0 45.3 52.0 59.1 66.8 74.9 83.4 92A 101.9 30 23.9 26.4 29.0 31.6 34.6 40.4 46.9 53.8 61.3 659.2 77.5 86.4 95.7 105.5 35 24.5 27.1 29.7 32.5 35.3 41.5 48.1 55.2 62.8 70.9 79.5- 88.6 98.2 108.3 40 25.2 27,7 30.5 33.3 36.2 42.5 49.3 56.6 64.4 72.7 81.5 90.9 100.7 111.0 45 257 28.3 31.1 34 O 37.0 434 503 57.8 65.7 74.2 133.2 92. 1 2. 113.3 50 7.7 3 51.3 58.9 67.1 75.7 84.9 1 -94.6 1 a4.8 115.5 55 26.6 72 38.3 45.11 52 59.9 68.1 76.9 :[:]] 8 96-16 106.4 117.4 60 2 .O 5 58.9 45.1 7 60 8 69.2 78.1 81.567 971 -91-b 108.1 119.2 100 48.9 5`5 9 62. C, 53 2 2 83.2 94.6 106.8 119.8 1 -133.4 147.9 163 1) Tables 3, 4, and 5 are based -on ASCE 7-10 and consistent with the 2015 IBC 2015 IRC G, A Wq Ile t Ft ogO fi I iif RONALD 1. OGAWA ASSOCIATES, INC. 161335 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 T) 714-292-2602; (F) 714-847-4595 PROJECT: RIO-2689-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com Table 6, Allowable Wind Speed (mph) for HardlePanel Siding (Analytical Method in ASCE 7-10 Chaptel,30 C&C Part I and Part 3)' Allowable, Ultimate Allowable, Nominal Design Alind, Speed, Design Wind, Speed, V,,315, V-415, 3-second gust mph) 3-second gust mph) Applicable to methods specified in 12015 IBC, Applicable Io method. 2017 FBq Section specified in ExcepliDrs I 1609.1.i.asdetertTfinedby through3ofI2015113C, 2015 IBC, 2017 FBCI 2017 FBC] Section Figures 1609.3(l),(2), or 1609.1.1. 3). 1 C2 cients med in Table 6 calculations for Wnd aynn77m i,alannl Wnei --- r,iti,ri-I d_- K_ I Product Minimum Thickness in-) VvIdth in.) an rFaste Type Fastener Spacing in.) Frame Type Stud Spacing in.) Building Height2-5 Ill) B C D 8 C 0 Adlowabie Design Load P-0 Exp B Exp C Exp D 1, GC,, GC, HardiePanelS 5/16 48 No. 8 X 1.25' long X 0.323" HD ribbed bugle head screws 6" D.C. into furring only 2X4 wood or 20 ga. steel framing, 3/4* thick by 3.5 wide wood turning 16 0_15 193 175 159 149 135 123 53.6 0.70 0.85 1.03 60 1 D.85 1.4 0.18 20 193 170 155 149 132 120 53.6 0.70 0.90 1.08 1 0.85 1.4 0.18 25 193 166 152 149 129 116 53.6 0.70 0.94 1.12 1 0.85 1.4 0.18 30 193 163 150 149 126 116 53.6 0.70 0.98 1.16 1 085 1.4 0.18, 35 189 160 1 148 146 124 1 114 53.6 0.73 1 1.01 1 1.19 140.815 1. 04 0.181 40 185 158 146 143 122 113 53.6 0.76 1.04 1.22 1 0.85 1.4 0.18 45 172 150 140 133 116 108 53a6 0.88 115 1.33 1 0.85 1.4 D.18 60 179 154 143 139 120 111 53.6- 0.81 1.09 1.27 1 0.85 1.4 DAB 55 177 153 142 137 119 110 536 0.83 1.11 1.29 1 0.85 1.4 018 60 175 152 141 135 117 109 53.6 7_ 85 T_ 1.13 1.31 I1 0.135 I1.4 1i, D.18 100 145 128 120 112 99 93 536 099 126 1.43 h>60 1 0.851 1.8 0.18 HardiePanelO 5116 48 No. 8 X 1.25' long X 0.323' HD ribbed bugle head screws 81' O.C into funing only 2X4 wood or 20 ga. steel framing, 314' thick by &S' wide wood furring 16 0-15 1 174 158 144 135 122 111 43.8 0.70 0.85 1.03 hs60 1 0-951-1.4 1 0.18 20 174 154 1 140 135 119 1 109 43.8 0.70 0.90 1.08 1 0.851 1.4 10.181 25 174 150 138 135 116 107 43.8 0.70 O.N 1.12 1 0.851 1.410.181 30 174 147 135 135 114 105 43.8 0.70 0.98 1.16 085 14 118 35 171 145 134 132 112 103 43.8 0.73 1.01 119 L 1 0.95 AA 0.18 40 76-7 143 132 129 Ill 102 43.8 0.76 1 .04 1.22 1 0.85 1.4 0.18 45 164 141 131 127 109 101 43.8 0.79 1-07 1.25 1 0 135 1.4 0.18 50 162 140 129 125 108 100 43.8 0.81 109 1.27 1 F _85 1.4 0.18 16 138 128 124 107 99 43.8 0.83 1.11 1.29 1 0_85 1.4 0.18 60 158 137 127 122 106 99 43.8 0.85 1.13 1.31 1 0.85 1.4 0.18 100 131 116 101 9() 1 -43.8 0.99 1-26 1.43 h 60 1 0.85 1.8 0.18 HardiePanelO 5/16 48 No. 8 X 1.25*long X 0.323' HD ribbed bugle head screws 10"O.C. into furring only 2X4 wood or 20 ga. steel framing, 31. thick by 3.5' wide wood furring 16 0-15 164 149 135 127 115 105 1 -38.8 0.70 085 1.03 hs60 1 0.85 1.4 0.18 20 164 145 132 127 112 102 38.8 0.70 0.90 1.08 1 0.85 1.4 0.18 25 164 141 130 127 110 100 38.8 0.70 0.94 T12 1 T.-O 1.4 D 18 30 164 139 127 127 107 99 38.8 0.70 0.98 1.16 1 0.85 1.4 0.18 35 161 136 126 124 106 97 38.8 0.73 1.01 1.19 1 7-8-5- 1.4 0.18 40 157 134 124 122 104 96 38.8 0.76 l.D4 1.22 1 0.85 1.4 0.18 45 155 133 123 120 103 95 38.8 0-79 1.07 1.25 1 0.85 1.4 0.18 50 152 131 122 118 102 94 38.8 0.81 1.09 1.27 1 D.BS 1.4 0.18 55 151 130 121 117 101 94 38.8 0.83 1.11 1 29 1 10.85 1.4 1110.18 60 149 129 120 115 100 93 38.8 0.85 1.13 1.31 1 10. 8 51- 1.4 D. 100 123 95 38.8 0.99 1.26 1-43 ti 50 1 10.85 1.8 111,8 0.18 HardiePanel@ 5/16 48 No. 6 X 1.25"long X 0.323' HD ribbed bugle head screws 12"O.C. into furring only 2X4 wood or 20 ga. steel framing, 314- thick by 3.5' wide wood furring 16 0-15 157 142 129 121 Ill) 100 35.4 0.70 0.85 1.03 hs6O 1 0.85 1.4 0.18 20 157 138 126 121 107 98 35.4 0.70 0.90 1.08 1 0.85 1.4L 0 18 25 157 135 124 121 105 96 35.4 C.70 0.94 1.12 1 0.85 1.4 0.18 30 157 132 122 121 103 94 35.4 0.70 0.98 1.16 1 0.85 1.4 0.18 35 153 130 120 119 101 93 35.4 0.73 1.01 1.19 0.85 1.4 0.18 40 150 128 119 116 100 92 35.4 0.76 I.D4 122 1 0ML5 1.4 0.18 45 148 127 117 115 98 91 35.4 0.79 1.07 1-25 1 0.85 1.4 018 50 146 125 116 113 97 91) 35A 0.81 1.09 1.27 1 0.05 1.1 2 !E 55 1 124 115 ill 96 89 4- 0-83 1.11 1.29 P 0.85 1.!4 1).111fO. El 60 142 123 114 110 95 89 435 0.8 5 1A3 7.3-1 0.85 1.44 100 118 91 384 0.99 1 1.26 1 1.43 1 h 601 1 0.155 I.LLL j i)GNWA SE LLJ FLO' S S . I . 0 . RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 T) 714-292-2602: (F) 714-B47-4595 PROJECT: RIO-2689-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com Allowable, Ultimate Allowable, Nominal Design Wind, Speed, Design Wind, Speed, V'3.5' V.,W4.5. 3-second gust mph) 3-second gust mph) Applicable to methods specified in [2015 19C, Applicable to methods 2017 FBC] Section specified in Exceptions I 1609.1.1. as determined by through 3 of 12015 IBC, 121115 IBC, 2017 FBq 2017 FBq Section Figures 1609.30),(2), or 1609.1.1. 3). Coefficients us,ed in Table 6 calculations for V., Wn-d exposure category Wind exposure category Siding K Product Minimum Thickness in.) V'Adth in.) Fast ener T pey Fastener Spacing in.) Frame Type Stud Spacing in.) Building Height ft.) B I DI B I AJ10'able Design Load pso Exp 6 Exp C Ep D K, Kd I GC, GC, 0-15 138 125 114 107 97 88 27.6 0.70 0.85 1.03 h560 1 0.851 1.4 0.18 20 138 122 ill 107 94 B6 27.6 0.70 0.90 1.08 0.95 1.4 0.18 HardiePanelS 5/16 48 No. 8 X 1.25" long X 0.323" HD fibbed bugle head screws 8" O.C. into furring only 2X4 wood or 20 ga. steel framing, 314" thick by 3.5' wide wood furring 1.7.5 24 25 138_ 119 107 92 27.6 0.70 0.94 1-12 L 1 0.85 1.4 0.18 30 138 71 7 107 91 27X 071 091 1 16 1 181 14 0118 35 135 115 105 89 27.6 0.73 1.01 1.19 1 085 1.4 0 " 40 133 113 103 88 27.6 0.76 1.04 22 1 0.85 1.4 018 45 131 112 101 87 27.6 0.79 1.07 1.25 1 1 7-- 65 0.85 1.4 1.450129ill1006627.6 0.81 1.09 1.27 55 127 98 27.6 0.83 1.11 1.29 1 0.85 1.4 0.18 60 125 97 27.6 0.85 1.13 1.31 F-1 -T 0.85 1.4 0.18 100 27m6 0.99 1.26 1.43 lh 601 1 10.85 1.8, 0.18 0-15 185 168 152 143 130 118 49.2 0.70 0.85 1.03 lh 60 1 0.85 1.4 0.18 20 185 163 149 143 126 115 49.2 0.70 0.90 I:LB_ 185 14 1 18 HardiePanel@ SM6 48 0.090" shank X 0.215' HD x 1.5" long ring shank nail 6- O.C. into furring only 2X4 wood or 20 ga. steel framing, 3/4' thick by 3.5' wideWODd furring 16 25 185 159 146 143 123 113 i9.2 0.70 0.94 1.12 L 1 085 1-4 018 30 185 156 143 143 121 ill 49.2 0.70 0.98 1.16 1 55 1.4 DA8 35 181 154 142 140 119 110 49.2 0.73 1.01 1.19 4 0.18. 40 177 151 140 137 117 108 492 0.76 1.04 1-22 4 0-18 45 174 150 138 135 116 107 49.2 0.79 1.07 1.25 1 4 DAB 50 172 148 137 133 116 106 49.2 0.131 1.09 1.27 015 1 1 0.18 55 170 147 136 131 114 105 49.2 0.83 1.11 1.29 1 4 71-8 13EI 1 0 113 105 49.2 0.85 1.13 1.31 till, 14 0.18 21 1 1 1. 7 95 89 0.99 1-26 1.43 h>61 7718 i. turnng anam ni to structu i iraming embers or an mame ru g wou, snail De -S19neo Dy an engineer, 2. Building height = mean roof height (in feet) of a building, except that eave height shall be used for roDf angle 0 less than or equal to 1 D' (2-12 roof slope). 3. V,,, = ultimate design wrind speed. 4. V_i = nominal design Wnd speed 5. Linear interpolation of building height is 60 ft) and Wnd speed is permitted. 6. Wind speed design assumptions per Analyfical Method in ASCE 7-10 Chapter 30 C&C Part I and Part 3: K =1, K,=0.85, GC,i=1.4 (hi;60), GC,1,8 (h,60). GC,,-0.18. 7. Wood furring shall be pmsemtiw treated per AVk/PA. B. Wood furring shall be specific gramty of 0.42 or greater per AFPAINDS or Wood st-tural panel, conforming to DOC PS-1 or DOC PS-2 or APA PRP-1 08. LIMITATIONS OF USE: 1) In High Velocity Hurricane Zones (HVHZ) install per Miami -Dade County Florida, NOA 17-0406.06 A WA OA Ss 10 14 PROJECT RIO-2686-17 ENGINEERING EVALUATION REPORT FOR ATTACHING JAMES HARDIE0 BRAND FIBER -CEMENT PANELS TO WOOD AND METAL FRAMED WALLS WITH VARIOUS FASTENERS JAMES HARDIE BUILDING PRODUCTS, INC. 10901 ELM AVENUE FONTANA, CA 92337 TABLE OF CONTENTS PAGE COVER PAGE 1 EVALUATION SUBJECT 2 EVALUATION SCOPE 2 EVALUATION PURPOSE 2 REFERENCE REPORTS 2 TEST RESULTS 3 TABLE I A, RESULTS OF TRANSVERSE LOAD TESTING 3 TABLE I B, SHEAR VALUES 3 DESIGN WIND LOAD PROCEDURES 4 TABLE 2, COEFFICIENTS AND CONSTANTS USED IN DETERMINING V AND p 4 TABLE 3, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE B 5 TABLE 4, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE C 5 TABLE 5, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE D 5 TABLE 6, ALLOWABLE WIND SPEED (MPH) FOR HARDIEPANEL SIDING 6-7 LIMITATIONS OF USE 7 AS PRODUCT EVALUATOR, THE UNDERSIGNED CERTIFIES THAT THE LISTED PRODUCTS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE ASCE 7-10, THE 2017 FLORIDA BUILDING CODE, AND THE 2015 INTERNATIONAL BUILDING CODE. PREPARED BY: RONALD 1. OGAWA & ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4-595 FAX A WA SE FLO 10ss! o RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-8138-542-7343 info@jameshardie.com EVALUATION SUBJECT HardiePanel@ Siding James Hardie Product Trade Names covered in this evaluation: HardiePeneig Siding, Cempanel@ Siding, Prevail- Panel Siding EVALUATION SCOPE: ASCE 7-10 2017 Florida Building Gods 2015 International Building Codeg EVALUATION PURPOSE: This analysis is to determine the maximum design 3-second gust wrind speed to be resisted by an assembly of HardiePanel (Gempanel, Prevail Panel) siding fastened to wood or metal framing with nails or screws. REFERENCE REPORTS: 1. Intertek Report aD67913 (ASTM CI 186) Material properties HardiePanef Siding 2. Ramtech Laboratories Report IC-1 27D-94 (ASTM E330) Transverse Load Test, 5/16" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem-Firwood studs spaced at 16 inches on center with a 6d common galvanized nail 3. Ramtech Laboratories Report IC-1 271-94 (ASTM E330) Transverse Load Test, 5/16" Thick by 48 inch wide HardlePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 24 inches on center with a 6d common galvanized nail 4. Ramtech Laboratories, Inc. Report 10868-9711475 (ASTM E330) Transverse Load Test, 5116" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Group III SG=0.36 wood studs spaced at 16 inches on center with a 4d, 0.091 inch shank by 0.225 inch head diameter by 1.5 inch long ring shank nail 5. Ramtech Laboratories, Report IC-1 054-89 (ASTM E330) Transverse Load Test, 1/4" Thick by 48 inch wide HardiePanel Siding installed on 20gauge Metal studs spaced at 16 inches on center with a No 8 X I in. long X 0.323 in head diameter ribbed bugle head screw 6. Ramtech Laboratories, Report IC-1055-89 (ASTM E330) Transverse Load Test, 114" Thick by 48 inch wide Hardielpanel Siding installed on 20gauge Metal studs spaced at 24 inches on center Wth a No 8 X I in. long X 0.323 in head diameter ribbed bugle head screw 7. Ramtech Laboratories, Report 11 149-98/1554d (ASTM E330) Transverse Load Test, 114" Thick by 48 inch wide HardiePanel Siding installed on 20gauge Metal studs spaced at 16 and 24 inches on center with a ET&F 0.100 in. knuried shank X 1.5 in. long X 0.25 in. head diameter pin fastener 8. Ramterh Laboratories Report IC-1273-94 (ASTM E72) Racking Shear Test, 5/16' Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 16 inches on center Wth a 6d common galvanized nail 9. Ramtech Laboratories Report IC-1274-94 (ASTM E72) Racking Shear Test, 5116" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 24 inches on center with a 6d common galvanized nail 10. Ramtech Laboratories, Inc. Report 10868-9711475 (ASTM E72) Racking Shear Test, 5/16'Thick by 48 inch wide Hardielpanel Siding installed on 2X4 Group III SG=0.36 wood studs spaced at 16 inches on centerwrth a 4d. 0.091 inch shank by 0.225 inch head diameter by 1.5 inch long ring shank nail 11. Ramtech Laboratories Report IC-1057-89 (ASTM E72) Racking Shear Test, 5/16"Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem-Firwood studs spaced at 16 and 24 inches on center with a No 8 X I in. long X 0.323 in head diameter ribbed bugle head screw 12. Ramtech Laboratories Report 11284-99/1580 (ASTM E72) Racking Shear Test, 5116" Thick by 48 inch wide HardiePanel Siding installed an 2X4 Hern-Fir wood studs spaced at 16 and 24 inches on center with a ET&F 0.100 in. knurled shank X 1.5 in. long X 0.25 in. head diameter pin fastener I OGA STWE OF N lit RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com TEST RESULTS: Table I a, Results of Transverse Load Testing Fastener Spacing Nlowable Frame Ultimate Design Thickness Width Spacing Perimeter Field Load Load' Report Number Test Agency in.) in.) Frame Type in.) Supports Supports Fastener Type PSF) PSF)_ IC-1270-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 16 6 6 6d common 149 49.7 IC-1270-94 Ramech 03125 48 2X4 wood Hem -Fir 16 4 4 6d common 236 78.7 IC-1271-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 24 6 6 6d common 94 31.3 IC-1271-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 24 4 4 6d common 143 47.7 4d, 0.091 in. shank X 0.225 in. 1086B-9711475 Ramtech 0.3125 48 2X4 wood, SG Zt 0.36 16 4 8 HD X 1.5 in. long ring shank nail 90 30.0 Min- No 8 X I in. long X 0.323 in IC-1054-89 Ramterh 0.25 48 Min. No. 20 gauge X 3.625 in. X 16 6 6 head diameter dbbed bugle 169.9 56.6 1.375 in metal stud head screw Min' No 8 X I in. long X 0 . 323 in IC-1055-89 Ramtech 0.25 48 Win. No. 20 gauge X 3.625 in. X 24 6 6 head diameter ribbed bugle 91.9 30.6 1.375 in metal stud head screw Min. No. 20 gauge X 3.625 in. X ET&F 0,100 in. knurled shank X 11149-9811 554d Ramtech 0.3125 48 16 4 8 1.5 in. long X 0.25 in. head 170 56.7 1.375 in metal stud I diameter pin fastener ET&F 0.100 in, knuded shank X 11 149-9811554d Ramtech 0.3125 48 Min. No. 20 gauge X 3.625 in. X 24I 4 8 1.5 in. long X 0.25 in. head I 1.375 in metal stud diameter pin fastener 1. IUWZIUW LQUU is ine uiumale LOaC UIVIUM Dy d r-UT U1 5-Ly Ul . 2. HardiePanel Siding complies with ASTM C1 186, Standard Specification for Grade fl, Type A Non -asbestos Fiber -Cement Flat Sheets. Table 1b, Shear Values Allowable Loads in Pounds Per Lineal Foot for Panel Shear Walls" Fastener Spacing r,n ) I Frame Ultimate Allowable Thickness Width Spacing Perimeter Field Load 3 Load 3 Report Number Test Agency in.) in.) Frame Type in.) Supports Supports Fastener Type plf) 00 IC-1273-94 Ramtech 0.3125 48 2X4 Wood Hem -Fir 16 6 6 6d common 603.8 201.3 IC-1273-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 16 4 4 6d common 698.8 232.9 IC-1274-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 24 6 6 6d common 460.0 153-3 IC-1274-94 Ramtech 2312.5 48 2X4 wood Hem -Fir 24 4 4 6d common 637.5 212.5 1 0.091 in. shank X 0.225in 10868-97fi475 Ramtech 0.3125 48 2X4 wood, SG 2t 0.36 16 4 8 4d, I HD X 1,5 in. long ring shank nail 595A 198.5 Min. No 8 X 1 in. long X.Q.323 in IC-1057-89 Ramtech 0.25 48 Min. No. 20 gauge X 3.625 in. X 16 & 24 6 6 head diameter ribbed bugle 990.0 123.8 1.375 in metal stud head screw ET&F 0. 100 in. knuried shank X 11284-9911580 Ramtech 0.3125 48 Min. No. 20 gauge X 3.625 in. X 16 4 8 1.5 in. long X 0.25 in. head 1227.0 153.4 1.375 in metal stud diameter pin fastener 0.100 in. knurled Min. No. 20 gauge X 3.625 in. X 11284-99/1580 Ramtech 0.3125 48 1.375 in metal stud 24 4--7'ET&F 8 1.5 in. long X 0.25 in.= 1060.0I 132 5 1 1 diameter pin fastener 1. All board edges shall be supported by traming. Panels Shall be applied with the long dimension either parallel or perpendicular to studs. 2. The ma)dmum height-to4ength ratio for construction in this Table is 2:1. of 3. In the steel framed assemblies the allowable load is based on the average load at 1/8 inch net deflection, illif G A W4 ol.......... 3 K I Wall Zone 5 Height (ft) Exp B Exp C Exp D V K,, I GC, 0-15 0.7 0.85 1.03 h:560 1 1 0.85 1.4 0.18 20 0.7 0.9 1.08 1 0.85 1.4 KGIC0.18 25 0.7 0.94 1.12 1 0.85 1.4 0.18 30 0.7 0.98 1.16 1 0.85 1.4 0.18 35 0.73 1.01 1.19 1 0.85 1.4 0.18 4D 0.76 1.04 1.22 1 1 0.85 1.4 0.18 1 45 0.785 1.065 1 1.245 1 1 0.85 1.4 0.18 50 0.81 1.09 1.27 1 0.85 1.4 0.18 55 0.83 1.11 1.29 1 1.4 0.18 60 0.85 1.13 1.31 1.4 0.18 100 1 0.99 1.26 1.43 1 h,60 1 0.85 1.8 0.18 RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com DESIGN WIND LOAD PROCEDURES: Fiber -cement siding transverse load capacity (wind load capacity) is determined via compliance testing to transverse load national test standards. Via the transverse load testing an allowable design load is determined based on a factor of safety of 3 applied to the ultimate test load. Since the allowable design load is based on factor of safety of 3, allowable design loads on fiber -cement siding correlate directly to required design pressures for Allowable Stress Design, and therefore should be used with combination loading equations for Allowable Stress Design (ASD). By using the combination loading equations for Allowable Stress Design (ASD), the tested allowable design loads for fiber -cement siding are aligned with the wind speed requirements in ASCE 7- 10 Figure 26.5-1A, Figure 26.5-1 B. and Figure 26.5-1 C. For this analysis, to calculate the pressures in Tables 3, 4. and 5, the load combination will be in accordance with ASCE 7-10 Section 2.4 combining nominal loads using allowable stress design , load combination 7. Load combination 7 uses a load factor of 0.6 applied to the wind velocity pressure. Equation 1, %=0.00256'1<,'l<z V2 fref ASCE 7-10 equation 30.3-1) q, velocity pressure at height z Kz velocity pressure exposure coefficient evaluated at height z K topographic factor K, wind directionality factor V basic wind speed (3-second gust MPH) as determined from [2015 IBC, 2017 FBC] Figures 1609.3(l), (2), or (3); ASCE 7-10 Figures 26.5-1A, B, or C Equation 2, V=VIA fref 2015 IBC & 2017 FBC Section 1602-1 definitions) V , ultimate design wind speeds (3-second gust MPH) determined from [2015 IBC, 2017 FBCJ Figures 1609.3(1), (2), or (3); ASCE 7-10 Figures 26.5-1 A, B, or C Equation 3, p=q,*(GCrGCj) (ref ASCE 7-10 equation 306-1) GCp product of external pressure coefficient and gust -effect factor GCpj product of interrial pressure coefficient and gust -effect factor p design pressure (PSF) for siding (allowable desgn load for siding) To determine design pressure, substitute q. into Equation 3, Equation 4, p=0.00256*K*K,*Kd*\/,2*(GCF-GcpiI Allowable Stress Design, ASCE 7-10 Section 2.4. 1, load combination 7 Equabon 5, 0.61) + 0.6W (ref. ASCE 7-10 section 2.4. 1, load combination 7) D deadload W windload To detenvine the Allowable Stress Design Pressure, apply the load hactorfor W(wind) from Equation 4 to p (design prLssure) determined from equation 4 Equation 6, P.. = 0.6*1Pj Equation 7, P d = 0.6*[0.00256*K2*Kz'Kd-VL,2(GCP-Gcpi)I Equation 7 is used to populate Table 3, 4, and 5. To determine the allowable ultimate basic wind speed for Hardie Siding in Table 6, solve Equation 7 for V., Equation 8, V k = (p.d/0.6*0.00256*K*K.*K*(GCrGCi))D-s Applicable to methods specified in Exceptions I through 3 ol'12015 18C, 2017 F8Cj Section 1609.1.1., to determine the allowable nominal design windspeed (Vasd) lorHardie Siding in Table 6, apply the conversion formula below, Equation 9, V, = V. * (0.6)0" fref 2015 IBC & 2017 FBC Section 1609.3. 1) V, , Nominal design wind speed (3-second gust mph) (ref. 2015 IBC & 2017 FBC Sec6q,5)99Y#1'"r-"-, Table 2, Coefficients and Constantsused in Determining V and p, '011 _21 0 ...... W'4 NO. -1-LYIV- I RONALD 1. OGAWA ASSOCIATES, INC- 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-268&-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com Table 3, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category B, Wind Speed (3-second gust) 100 105 110 115 120 130 140 150 160 170 180 190 200 210 Height (ft) B B B B B B B 8 B a B S. 8 8 0-15 14.4 15.9 17.5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 20 14.4 15.9 17.5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 25 14.4 15.9 17.5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63T 30 14.4 15.9 17.5 19.1 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 35 15.1 16.6 18.2 19.9 21.7 25.4 29.5 33.9 38.6 43.5 48,8 54.4 60.2 66.4 40 1 -15.7 1 -17.3 1 -19.0 1-20.7 22.61 26.5 1 -30.7 35.3 40.1 45.3 50.8 56.6 62.7 6 .1 45 16.2 17.9 19.6 21. 23.3 27.4 31.7 36.4 41.6 46.8 52.5 58.5 4.8 71 A 50 16.7 18.4 20.2 22A 24.1 28.2 32.7 37.6 42.8 48.3 54.1 60.3 66.8 73.7 55 17.1 18.9 20.7 22.6 24.7 33.6 38.5 43.8 49.5 55.5 61.8 68.5 75.5 60 4 ' 1712- 25. 259 34.4 39.5 W-.9 TO-7- 76-6 -8 63.3 70.11-102.4 77.3 100 25.6 28.2 31 !l 36.9 43.3 50.2 57.6 65.6 74.0 82.9 92.4 112.9 Table 4, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category C, Wind Speed (3-second gust) 100 105 110 115 120 1 130 140 150 1160 170 180 190 200 210 Height (ft) C C C C C C C C C C C C C C 0-15 17.5 19.3 21.2 23.2 25.2 29.6 34.4 39.5 44.9 50.7 56.8 63.3 70.1 77.3 20 18.6 20.5 22.5 24.6 26.7 31.4 36.4 41.8 47.5 53.7 60.2 67.0 74.3 8TT 25 19.4 21.4 23.5 25.6 27.9 32.8 38.0 43.6 49.6 56.0 62,8 70.0 77.6 85.5 30 20.2 22.3 24.5 26.7 29.1 34.2 39.6 45.5 51.8 58.4 65.5 730 80.9 89.2 35 20.8 23.0 25.2 27.6 30.0 35.2 40.8 46.9 513 60.2 67.5 75.2 83.3 91.9 40 21.5 23.7 26.0 28.4 30.9 36.3 41ZO 48.3 5-4.9 62.0 69.5 77.4 85.8 94.6 45 22.0 242 266 29. 1 31.6, 37.1 43.1 49.4 56.2 63.5 71.2 79.3 87.9 96.9 50 22.5 724.8 2 29.7 32 j 1 44-11 50.6 576 65.0 72 2 8 55 22.9 25.2 273 30.3 i5 01 3,T 44.9 51 5 58.6 66.2 22 20.7 921 2 190, 60 23.3 257- 28.2 30.8 33.b 1 -39.4 1 4b. 1 2.4 9. 6-7.4 B 100 32.6 35.9 39.4a43.1 46.91 55.0 1 Table 5, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category D, Wind Speed (3-serond gust) 100 105 110 115 120 130 140 150 160 170 180 190 200 210 Height (ft) D D 0 D D D D D D D D D D D 0-15 21.2 23.4 25.7 28.1 30.6 35.9 41,6-- 47.8 54.4 61.4 68.8 76.7 85.0 93.7 20 22.3 24.6 27.0 29.5 32.1 37.7 43.7 50.1 57.0 6.4.4 72.2 80.4 89.1 98.2 25 23.1 25.5 26.0 30.6 33.3 39.0 45.3 52.0 59.1 66.8 74.9 83.4 92.4 101.9 3D 23.9 26.4 29.0 31.6 34.5 40.4 46.9 53.8 61.3 69.2 77.5 86.4 95.7 105.5 35 24.5 27.1 29.7 32.5 35.3 41.5 48.1 55.2 62.8 70.9 79.5 88.6 98.2 108.3 4D 25.2 27.7 30.5 33.3,-36.2, 42.5 49.3 56.6 64.4 723 81.5 90.9 100.7 1 . 45 25.7 2&3 31.1 34.0 37.0 43.4 60.3 57.8 65.7 74.2 63.2 92.7 102.7 113.3 50 26.2 28.9 31.7 34.6 37.7 44.3 51.3 58.9 67.1 75.7 84.9 946 104.8 115.5 55 26.6 29.3 32.2 35-2 383 45.0 52.2 2 68.1 76.9 86.2 96.1 106.4 117.4 60 27-0 72-9-.8 Y2 -7 755.7 38.9 45.7 3.0 INI 91.2 7-1.1 7F7 -1 97 -6 108.1 9.2 100 37.0 40.8 44.7 48.9 53.21 62.5 72.5 106.8 119.8 133.4 Tables 3, 4, and 5 are based an ASCE 7-10 and consislent with the 2015 IBC, 2015 IRC and the 2017 Florida Building Code 0dt WA ZA W PLO' 5 RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-B47-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-BBS-542-7343 611, i3GAWinfo@jameshardie.com Table 6, Allowable Wind Speed (mph) for HardiePanef Siding (Analytical Method in ASCE 7-10 Chapter 30 C&C Part land Part 3) 7 2015 IBC, 2017 FBC 2015 IBC, 2017 FBC Allowable, Ultimate Allowable, Nominal Design Wind, Speed, Design Wind, Speed, I 1 r- V'aO' V.dsS, SIN 3-second gust mph) (3-second gust mph) Applicable to methods Applicable to methods specified in 12015 18C, 2017 FBC] Section specified in Exceptions 1 609.1.1. as determined by through 3 of [2015 IBC, Figures (2), or 2017 FBC] Section 3). 1609.1.1. exposure 06/0N t Coefficients used in Table 6 calculations for Siding I K, I Product Product Thickness inches) Width inches) Fastener Type Fastener Spacing Frame Type Stud Spacing inches) Building H eight3,7 feet) C D 8 C D Allowable Design Load PSF) Exp B Exp C Exp D K K GC, GCO HardiePaneM 5/16 48 6d common 6 2X4 wood Hem -Fir 16 0-15 186 168 153 144 130 118 49.7 0.7 0.85 1.03 h!ZD 1 0_a5 1.4 0.18 20 186 164 149 144 127 116 49.7 0.7 0.9 i.oB 719 1.4 0.18 25 186 160 147 144 124 114 49.7 0.7 0.94 1.12 1 0.85 1.4 0.18 30 186 157 144 144 121 112 49.7 0.7 0.98 1.16 1 0.85.-1.4 0.18. 35 182 154 142 141 120 110 49.7 0.73 1.01 1.19 1 Q.as 1.4 0.181 40 178 152 141 138 118 109 49.7 0.76 1.04 1.22 1 a 1_4 0,181 45 175 150 139 136 117 108 49.7 L7 I 1.245 1 0.85 11.4 0.18 5 1 2 149 138 134 115 107 49.7 n il 1ff T.27 I 0.85 O.a5 1.4 0.18 55 170 147 137 132 114 106 49.7 0.83 1.11 1.29 1 0.85 1:4 0.18 60 168 146 136 130 113 105 49.7 0.85 1.13 1.31 1 0.85 14 T 18 100 139 124 116 108 96 90 49.7 0.99 1.26 1.43 h,60 1 0.86 1.8 0.18 HardiePanel@ 5/16 48 6d common 4 2X4 mod Hem -Fir 16 0-15 233 212 192 181 164 149 78.7 0.7 0.85 1.03 h:560 1 0.85 1.4 018 20 233 206 188 181 159 146 78.7 0.7 09 1.08 1 0.85 1.4 0.18 25 233 201 185 181 156 143 78.7 0.7 0 94 1.12 1 0.85 1.4 0.18 30 233 197 181 181 163 140 78.7 0.7 0.98 1.16 1 0.85 1.4 0.18 35 229 194 179 177 151 139 78.7 0.73 1.01 1.19 1 0.85 1.4 0.18 40 224 192 177 174 148 137 78.7 0.76 1.04 1.22 1 0.85 1.4 0.18 45 220 189 175 171 147 136 787 0.785 1-065 1-241 1 0.85 1.4 0.18 50 217 187 173 168 145 134 78.7 0.81 1.09 1.27 1 0.85 1.4 0.18 55 214 185 172 166 144 133 78.7 0.83 1.11 1.29 1 085 14 018 6D 212 184 171 164 142 132 78.7 0.95 1.13 1.31 1 0.85, 1.4 0.18 100 175 155 146 136 120 113 78.7 0.99 126 1.43 h 60 1 10.851-1.8 0.18 HardiePanel@ 5/16 48 6d common 6 2X4 wood Hem -Fir 24 0-15 147 134 121 114 103 94 31.3 0.7 0.85 1.03 h2ZO 1 0.85 1.4 0.18 20 147 130 119 114 101 92 31.3 P.7 0.9 1.08 1 085 1.4 0.18 25 147 127 116 114 98 90 31.3 0.7 0.94 1.12 1 0.85 1.4 0 1 a 30 147 124 114 114 96 89 31.3 0.7 0.98 1.16 1 0.85 1.4 0.18 35 144 123 113 112 95 87 31.3 0.73 1.01 1.19 1 0.85 1.4 0.18 40 141 121 112 109 94 86 31.3 0.76 1.04 1.22 1 0.85 1.4 0.18 45 139 119 110 108 92 86 31.3 0.785 1.065 1.245 1 o.a5 1.4 0-181 50 137 118 106 91 31.3 0.81 l.D9 1.27 1 085 1.4 0.18 65 135 117 105 91 31.3 0.83 1.11 1.29 r", 0.851 1.4 0.18 60 134 116 103 90 31.3 0. 5_ 1.13 1.31 F-1-4 D.18 100 ill 86 31.3 0.99 U6 1.43 h>60 85 8 018 HardiePenel@) 5116 48 6d common 4 2X4 wood Hem -Fir 24 0-15 182 165 i5o 141 128 116 47.7 0.7 0.85 1.03 hS60 1 0.85 1.4 0.18 20 182 160 146 141 124 113 47.7 0.7 0.9 1.08 1 US 1.4 018 25 182 157 144 141 121 111 47.7 0.7 0.94 1.12 1 0.85 1 .4 0.18 30 182 1 154 141 1 141 119 109 47.7 0.7 0.98 1.16 L 1 0.85 1.4 D.18, 35 178 151 139 138 117 108 47.7 0.73 l.Dl 1.19 1 0.85 1.4 0.18 40 174 149 138 135 116 107 47.7 0.76 1.04 1.22 1 0.85 1.4 018 45 172 147 136 133 114 106 47.7 0.785, 1.065, 1245 1 0 : 85 1.4 0.18 50 169 146 135 131 113 105 47.7 0.81 1.09 1.27 5.71.4 0.18 55 167 144 134 129 112 104 47.7 0.83 1 1.11 1.29 1 85 0-18 60 165 143 133 128 Ili 103 47.7 085 TFI13 31 0.85 1.4 1.4 0.18 100 137 121 114 106 94 88 47.7 0.99 1 26 1.43 h'60 I L85 1 8 0,18 HardiePaneIV 5/16 I 48 4d, 0.091 in. shank X 0.225 in. HD X 1.5 1 4 edge 8 field 2X4 SwoodG:0.36 16 0-15 144 131 119 112 101 92 30.0 0.7 0.85 1.03 hS60 1 0-85 1.4 0.18 20 144 127 116 112 98 90 30.0 0.7 09 1-08 11 0.85 1.4 13.18 25 144 124 114 112 96 89 30.0 0.7 0.94 1.12 1 85 1.4 018 30 144 122 112 112 94 87 30.0 0.7 0.98 IA6 1 0-85 1.4 0.18 35 141 120 ill 109 93 86 30.0 0.73 1.01 1.19 1 0.85 1.4 0.18 40 138 118 107 92 30.0 0.76 I.D4 1.22 1 0.85 1.4 0.16 45 136 117 105 30.0 0.785 1.065 1.245 1 0.85 1.4 0.18 50 134 116 104 9' 89 3 00 081 1 1.09 1.2 55 132 114 31160, 89 3E3 0.83 1.11 1.29 1 60 1 1 113 88 0.85 1 1.13 1.31 1 1 IN i i H go 3.11 0.99 1 1.26 1 1.43 jh 60 RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com 2015 IBC, 2017 FBC 2015 IBC, 2017 FBC A,Ilowable, Ultimate Allowable, Nominal Design Wind, Speed, Design Wind, Speed, v,,4,6, V's6' 3-second gust mph) 3-second gust mph) Applicable to methods Applicable to methodsspecifiedin (2015 IBC, specified in Exceptions 1 2017 FBC] Section through 3 of 12015 113C, 16D9.1.1. as determined by 201 7 FBCI SectionFigures1609.3(l),(2), or 3). Coefficients used in Table 6 calculations for Vx W-,nd exposure category Wrid exposure category Siding K, Product Stud Building Allowable Product Thickness Width Fastener Fastener Frame Spacing Heigh,3. 7 B C D B C ID Design inches) inches) Type Spacing Type inches) feet) Load PSF) Exp B Exp C Exp D K K, GC' acz 0-15 198 180 163 153 139 126 56.6 07 085 1 03 h2M 1) 85 14 018 20 198 175 159 153 135_ 123 56.6 0.7 0-9- 1.08 L 1 0.85 1.4 0.18 Min. No 8 X 25 198 171 157 153 132 121 56.6 0.7 0.94 1.12 1 0.85 1.4 0.18 1 in. long X Min. No. 30 198 167 154 153 130 119 56.8 0.7 0.98 1.16 1 OA5 1.4 0.18 0.323 in 20 ga. 35 194 165 152 150 128 118 56.5 073 1.01 1.19 lj head 33 mil) X 40 190 162 150 147 126 116 S6.6 0.76 1.D4 1.22 0.18HardiePanel& 1/4 48 diameter 6 3.625 in. 16 45 187 161 148 145 124 115 55.6 0.765 1.065 1.245 1 10.851-1.4 0ABribbed X 1.375 50 184 159 147 143 123 114_ 56.6 0.81 1.09 1.27 1 0.85 1.4 0.18buglehead in metal 55 182 157 146 141 122 12 56.6 0.83 1.11 1.29 1 1 OZ51 1.4 0.18stud screw' 60 180 156 145 139 121 112 56.6 0-85 1.13 1.31 0.18 100 149 132 124 115 102 96 56.6 0.99 1.26 1.43 h>60 1 0.85 1.8 0.18 0-15 146 1 132 120 113 102 93 30.6 0.7 0.85 1.03 lh:= 1 0.85 1.4 018 20 146 128 117 113 99 91 30.6 07 0.9 1.08 1 0.85 1.4 018 Min. No 8 X 25 146 126 115 113 97 89 30.6 0.7 0.94 1.12 1 T-8- 5 1.4 0.18 I in. long X Min. No. 30 146 123 113 113 95 88 30.6 0.7 0,98 1.16 1 0.85 1.4 0A80.323 in 20 ga. 35 143 121 112 110 94 86 30.6 073 1.01 T1 -9 1 O 85 1.4 0.18head33mil) X 40 140 1`19 110 108 93 85 30.6 0.76 1.04 122 1 0.85 1.4 0.18HardiePanel@1/4 48 diameter 6 3.625 in. 24 45 137 118 106 91 30.6 0.785 1.065 1 4 0.8 1 -1.4 0.18, ribbed X 1.375 50 135 117 105 90 30.6 0.81 1.09 1.27 1 0.85 1.4 0.181bugleheadinmetal 1 11 1 1" 104 90 30.6 0.83 1.11 129 1 085 1.4 0.18 screw' stud 96 2 1 115 102 89 1 -30-6 6--85- 1 0.851 1.4 0,18 100 30.6 O.B9 1.26 1.43 h-60 1 10.851-1.8 D- 18 G-15 198 180 163 153 139 127 56.7 0.7 0.85 1.03 hs6O 1 0.851-1.4 0.18ET&F 0. 100 in. 20 198 175 160 153 135 124 56.7 0.7 0.9 1.08 1 o.a5l 1.4 0.18 25 198 171 157 153 132 121 56.7 0.7 0.94 1.12 1 0.851-1.4 018knurled Min. No. 1 30 198 167 154 153 130 119 56.7 OR 0.98 1.16 1 0.851-1-4 0.18shankX20ga. 35 194 165 152 150 128 118 56.7 0.73 1.01 1.19 1 0.18. 1.5 in. long 4 edge 33 mil) X 40 190 163 160 147 126 116 56.7 0.75 1.04 1.22 1 0.85 1.4 0.181HardiePanelg5/'16 48 X 0.25 in. 8 field 3.625 in. 16 45 187 161 149 145 124 115 55.7 0.785 1.065 11, 0.85 11.4 0.18headX1.375 50 184 159 147 143 123 114 55.7 0.131 1.09 jl'2 4-5 727- 1 0.85 0.1a15-1.4 11.4 18diameter in metal 55 182 157 146 141 122 113 55.7 0.83 1.11 1.29 0.95 1.4 0.18stud pin fastener2 60 180 156 145 139 121 112 56.7 U5 1.13 1.31 1 i r0.85 11.4 T- 18 100 149 132 124 115 102 96 56.7 0.99 1.25 143 h>60 I O.B51 1.8 0.18 ET&F 0-15 153 139 126 118 107 98 33.7 0.7 0.85 I.L3_ h560 0.85 1.4 018 20 153 135 123 118 104 95 33.7 0.7 0.9 1.08 2_ 1 0.85 1.4 0180. 100 in. 25 153 132 121 118 102 94 33.7 0.7 0.94 1.12 1 6.-85- 1.4 0.18knurledMin. No. 30 153 129 119 118 100 92 33.7 0.7 0.98 1.16 1 0.85 1.41 0.181shankX20ga. 35 150 127 117 116 99 91 333 0.73 1.01 1.19 1 0.85 1.41 1).1811.5 in. long 4 edge 33 ml) X 40 147 125 116 114 97 90 1 -33.7 0.76 1.04 122 1 0.85 1.4 0,16HardiePaneig5/16 48 X 0.25 in. 8 field 3.625 in. 24 45 144 124 115 112 96 89 33.7 0.785 1.D65 1.245 1 0.85 1.4 0.18head X 1.375 50 142 122 113_ 110 95 88 33.7 0.81 1.09 1.2 1 0.85 1.4 0.18diameter in metal 55 140 121 113 109 94 87 33.7 083 111 1.29 P'401:5 7-4 0.18stud pin fastener2 61 1 2 120 112 107 93- 87 1 .33.7 0.85 1.13 1,31 Q.a5 1-4- 0.18 T_ 1 1 15 89 1 -33.7_ 0.99 1-26 jj 0.85 1.8 0.18 i. zcrews snau penetrate the metal framing at least three tull threads. 2. Knurled shank pins shall penetrate the metal framing at least 1/4 inch. 3. Building height = mean roof height (in feet) of a building, except that eave height shall be used for roof angle e less than or equal to 10* (2-12 roof 4. Vu, ultimate design wind speed 5. V nominal design %-And speed 6. Linear interpolation of building height Is 60 ft) and wind speed is permitted. 7. Wind speed design assumptions per Analytical Method in ASCE 7-10 Chapter 30 C&C Part 1 and Part 3: K c 1, Kd=0.85, GC,=-1.4 (hs60), GCP l LIMITATIONS OF USE: 1) Fastener pullout must be evaluated when installed a species of wood studs other than that which was tested. 2) In High Velocity Hurricane Zones (HVHZ) install per Miami -Dade County Florida, NOA 17-0406.06 13GAW4 LAIL-, Z 0 wl it Florida Building Code Online Page 1 of 2 Tic ar BCIS Home 1 Log In User Registration Hot Topics Submit Surcharge Stats &Facts Publications FBC Staff BCIS Site Map Links Search kjlfl\ Product Approval MUSER: Public Userd r Product Approval Meng > Product or Application Search > Application Lis > Application Detail FL # FL12194-R6 Application Type Revision Code Version 1017 Application Status Approved Comments Archived Product Manufacturer Aluminum Coils, Inc. Address/Phone/Email 5001 West Knox Street Tampa, FL 33634 813) 249-9743 grahman@aluminumcoilsinc.com Authorized Signature Gareth Rahman grahman@aluminumcoilsinc.com Technical Representative Paul Frost Address/Phone/Email 5001 West Knox Street Tampa, FL 33634 813) 249-9742 PFrost@aluminumcoilsinc.com Quality Assurance Representative Address/Phone/Email Category Panel Walls Subcategory Soffits Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 1: Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 06/19/2020 Validated By Locke Bowden R. Validation Checklist - Hardcopy Received Certificate of Independence FL12194 R6 COI ALC15001.3 2017 FBC Evaluation Report 04 T4 Soffits final.pd Referenced Standard and Year (of Standard) Standard AAMA 1402 Equivalence of Product Standards Certified By Sections from the Code Year 2009 https://www.floridabuilding.oro,/pr/p app dtl.aspx?param=wGEVXQvADquk24AUC%2fE... 2/1/2018 Florida Building Code Cinlie Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 09/06/2017 Date Validated 09/06/2017 Date Pending FBC Approval 09/13/2017 Date Approved 12/12/2017 Date Revised 12/15/2017 Summary of Products FL # Model, Number or Name Description 12194.1 Alumunum Coils Aluminum Soffit Aluminum soffit panels Limits of Use Installation Instructions Approved for use in HVHZ: No FL12194 R6 II ALC15001.3 2017 FBC Evaluation Report 04 T4 Soffits final.DdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: +80/-90 Created by Independent Third Party: Yes Other: See Evaluation Report for limits of use. Evaluation Reports FL12194 R6 AE ALC15001.3 2017 FBC Evaluation Repo 04 T4 Soffits final.Od Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee F 32399 Phone, 850-487-182 The State of Florida is an AA/EEO employer. Cogyricht 2007-2013 State of Florida. :: Privacy Statemen ;: Accessibility Statemen :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487. 1395. -Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Appro al Accepts: C e6a. Card - Safe: https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquk24AUC%2fE... 2/1/2018 Certificate of AuthorizGtion No. 29824 17520 Edinburgh DrREEKTampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BuILDING CODE 6 T" EDITION (2017) Manufacturer: ALUMINUM COILS, INC. Issued September 1, 2017 5001 West Knox Street Tampa, FL 33634 813) 249-9743 www.aluminumcoilsinc.com Manufacturing: Tampa, FL Quality Assurance: PRi Construction Materials Technologies (QUA91 10) SCOPE Category: Panel Walls Subcategory: Soffits Code Sections: 1404.5.1, 1709.10 Properties: Wind Resistance REFERENCES En!L Relport No. Standard Year Certified Testing Laboratories (TST1577) CTLA 1847VV AAMA 1402 2009 Certified Testing Laboratories (TST1577) CTLA 2076W AAMA 1402 2009 PRI Construction Materials Technologies (TST5878) ACIX-003-02-01 AAMA 1402 2009 PRI Construction Materials Technologies (TST5878) ACIX-003-02-02 AAMA 1402 2009 LIMITATIONS 1 . This report is not for use in the HVHZ. 2. Design wind loads shall be determined in accordance with FBC Section 1609. 3. Soffits shall be labeled in accordance with FBC Section 1709.10. 4. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's published application. instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5. Installations shall meet the minimum ventilation requirements of FBC section 1203.2. 6. Field fastener withdrawal may be required by the AHJ for confirmation of existing substrates. All data shall be reviewed by a qualified design professional to ensure the fastener withdrawal meets or exceeds the minimum load resistance for the project requirements. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. ALC15001.3 FL12194-R6 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ALUMINUM COILS, INC CREEK SoffitsNTECHNICALSERVICES, LLC PRODUCT DESCRIPTIONS 318" F-Channel Preformed nominal 0.016-inch thick, 3105 H-14 aluminum F-channel. See Appendix D for dimension drawings. 3/8" J-Channel Preformed nominal 0.016-inch thick, 3105 H-14 aluminum J-channel. See Appendix D for dimension drawings. Fascia Preformed nominal 0.019-inch thick, 3105 H-14 aluminum fascia. See Appendix D for dimension drawings. 16" Q4 Soffit Preformed nominal 0.0135-inch thick, 3105 H-14 aluminum soffit R anels provided in 16- inch sections. The reported net free ventilation areas are 22.3 in /lin.ft for the 'full vent' configuration and 11.1 in 2/1 in.ft and for the 'center vent' configuration. See Appendix D for dimension drawings. zz .. zz,,, Z'Z'Z—Z'Z'Z--, N, 16" FULL VENT 16" CENTER VE 12" T4 Soffit Preformed nominal 0.0135-inch thick, 3105 H-14 aluminum soffit R anels provided in 12- inch sections. The reported net free ventilation areas are 12.5 in /lin.ft for the 'full vent' configuration and 4.2 in 2/1 in.ft for the 'center vent' configuration. See Appendix D for dimension drawings. zzz—,, ZZ, n-z - ZZ 12" FULL VENT 12" CENTER VEN 12" SOLID PANE ALC15001.3 FL1 2194-R6 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT ALUMINUM COILS, INC Soffits The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. SO, 2017.09.010EN01\ No 74021 10-:06:18 0 -04'00' STATE OF 41J Z 441 -. Zachary R. Priest, P.E. Al OR Florida Registration No. 74021 A Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor wfli I acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A— Approved Systems (8 pages): 2) APPENDIX B— Installation Drawings (12 pages) 3) APPENDIX C — Design Wind Loads(4 pages) 4) APPENDIX D — Dimension Drawings (4 pages) ALC15001.3 FL12194-R6 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC APPROVED SYSTEMS ALUMINUM COILS, INC Soffits Appendix A The following notes shall be observed when using the assembly tables below. 1 . Maximum Design Pressures (MDP) were calculated using a 1.51 margin of safety per FBC Section 1404.5.1. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on -center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system. 5. Unless otherwise specified, the Wood substrate shall be minimum No. 2 SPF (S.G. = 0,42) 2x lumber. Substrate attachment shall be designed by others in accordance with FBC requirements to meet the minimum design requirements for the project. 6. Unless otherwise specified, the Masonry substrate shall conform to ASTM C 90. Substrate attachment shall be designed by others in accordance with FBC requirements to meet the minimum design requirements for the project. 7. Typical fastening details are as follows: a. 12" T4 Soffit — 12-inch o.c. Fastener Fastener Location Location b. 12" T4 Soffit — 4-inch o.c. Fastener Fastener Fastener Fastener Location Location Location Location c. 16" Q4 Soffit — 16-inch o.c. Fastener Location I — Fastener ALC15001.3 FL12194-R6 Page 1 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC d. 16" Q4 Soffit —8-inch o.c. Fastener Location Fastener Location Fastener Location ALUMINUM COILS, INC Soffits Approved System Numbers and Definitions 12F-# Approved Systems for 12-inch Overhang with F-Channel 12J-# Approved Systems for 12-inch Overhang with J-Channel 16F-# Approved Systems for 16-inch Overhang with F-Channel 16J-# Approved Systems for 16-inch Overhang with J-Channel 24F-# Approved Systems for 24-inch Overhang Wth F-Channel 24J-# Approved Systems for 24-inch Overhang with J-Channel Apo'endix A Approved Systems for 12-inch overhang with F-Channel W611 Connection Eave Connection System Panel MDP No. Width pso Substrate F-Channel Substrate Panel Attachment Fascia Cap Attachment Attachment Max. One (1) min. 3/8-inch head dia. nail, One (1) min. 3/8 x 3/8-inch One (1) min. 1 3/4-inch long x 0.072-inch dia. x min. 3/16- 12F-1 16-inch Wood min. 1.25-inch embedment spaced Wood crown staple spaced 16-inch inch head dia. trim nail 40.0 24-inch o.c. O.C. spaced 36-inch o.c. Max. Three (3) min. 3/4-inch x 1/4-inch One (1) min 3/4-inch x 1/4-inch One (1) min. 1 3/4-inch long x 0.072-inch dia. x min. 1/4-inch 48 12F-2 16-inch Wood crown staples in diamond pattern Wood crown staple spaced 8-inch o c head dia. trip nail spaced 48- 64.2 spaced 24-inch o.c. g each panel [aandsecurin p inch o.c. One (1) min 3/4-inch x 1/4-inch One (1) min. 1 3/4-inch long x 12F-3 Max Masonry One (1) 14 ga. 5/8-inch Iona. T nail Wood crown staple spaced 8-inch o.c. 0.072-inch dia. x min. 1/4-inch 48 16-inch spaced 8-inch o.c. and securing each panel lap head dia. trip nail spaced 48- 64.2 inch o.c. ALC15001.3 FL12194-R6 . Page 2 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, insta6tion, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, ILLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 12-inch overhang with J-Channel Wall Connection. Eave. Connection System Panel MDP No. Width Psf) Substrate F-Channel Panel Attachment Substrate Panel Attachment Fascia Cap Attachment.: Attachment Three (3) min. 3/4- inch x 1/4-inch crown One (1) min. #8 x 1/2-inch One (1) min 3/4-inch x One (1) min. 1 3/4-inch long x 12J-1 Max Wood staples in diamond long x 3/8-inch head diameter Wood 1/4-inch crown staple 0.072-inch dia. x min. 1/4-inch 48 16-inch pattern spaced 24- screw spaced 16-inch o.c. spaced 8-inch o.c. head dia. trip nail spaced 48- 64.2 inch o.c. connecting soffit to J-channel inch o.c. 0 Approved Systems for 16-inch overhang with F Chahnel Wall Connection Eave Connection System Panel MDP, No. Width pso Substrate F-Chan.nel Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga. 1/4-inch crown x One (1) min. 1.75-inch x 16F-1 Max Masonry One (1) 14 ga. 5/8-inch long T nail Wood 1-inch leg staple spaced max. 0.072-inch diameter finishing nail with min. 3/16- 53.3 12-inch spaced max. 8-inch o.c. 4-inch o.c. and securing each inch head spaced panel lap 12-inch o.c. One (1) 18 ga. 1/4-inch crown x One (1) min. 1.75-inch x Max. Three (3) 18 ga.1/4-inch crown x 1- 1-inch leg staple spaced max. 0.072-inch diameter 16F-2 12-inch Wood inch leg staples in diamond pattern Wood 4-inch o.c. and securing each finishing nail with min. 3/16- 53.3 spaced 16-inch o.c. panel lap inch head spaced 12-inch o.c. Max. One (1) 3/8-inchhead dia. nail, min, One (1) min 3/8-inch x 3/8-inch One (1) min. 1 3/4-inch long x 0.072 inch dia. x min. 16F-3 16-inch Wood 1.25-inch embedment spaced 24- Wood crown staple spaced 16-inch 3/16-inch head dia. trim nail 25.6 inch o.c. - O.C. spaced 36-inch o.c. Three (3) min. 3/4-inch x 1/4-inch One (1) rnin. 1 3/4-inch long 16F-4 Max. Wood crown staples in diamond pattern Wood One (1) min 3/4-inch x 1/4-inch x 0.072-inch dia. x min. 1/4- 27 16-inch spaced 24-inch o.c. crown staple spaced 8-inch o.c. inch head dia. trip nail 36.1 spaced 48-inch o.c. ALC15001.3 FL12194-R6 Page 3 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 16-inch.overhang with F-Channel Wall Connection Eave Connection. System Panel MDP No. Width Psf) Substrate F-Channel Attachment Substrate Panel Attachment Fascia, Cap Attachment One (1) 18 ga. 1/4-inch crown x One (1).min. 1.75-inch x 16F-5 Mix. Masonry One (1) 14 ga. 5/8-inch long T nail Wood 1-inch leg staple spaced 4-inch 0.072-inch diameter finishing nail with min. 3/16- 43.3 16-inch spaced 8-inch o.c. o.c. and securing each panel inch head spaced lap 16-inch o.c. One (1) 18 g a. 1/4-inch crown x One (1) min. 1.75-inch x Max. Three (3) 18 ga.1/4-inch crown x I- 1-inch leg staple spaced 4-inch 0.072-inch diameter 16F-6 16-inch Wood inch leg staples in diamond pattern Wood o.c. and securing each panel finishing nail wth min. 3/16- 43.3 spaced 16-inch o.c. lap inch head spaced 16-inch o.c. Approved Systems for 16-inch overhang with J-Channel Wall Connection Eave Connection System Panel MDP No. Width psf) Substrate J-Channel Attachment Substrate Panel Attachment Fascia Cap Attachment Max. Three (3) min. 3/4-inch x 1/4-inch One (1) min 3/4-inch x 1/4-inch One (1) min. 1 3/4-inch long x 0.072-inch dia. x 23.5 16J-1 16-inch Wood crown staples in diamond pattern Wood crown staple spaced 8-inch o.c. min. 1/4-inch head dia. trip 31.4 spaced 24-inch o.c. nail spaced 48-inch o.c. ALC15001.3 FL12194-R6 Page 4 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ALUMINUM COILS, INCCREEKSoffits TECHNICAL SERVICES, LLC Apoendix A id Systems for 24-inch overhangApprove with F-Channel Wall Connection Center Connection Eave Connection System Panel MDP No. width pso Substrate: F-Channel. Attachment . Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment One (1) 18 ga.1/4-inch Nominal 1x2 crown x 1 -inch leg No.2 SYP staple spaced Three (3) 18 ga.1/4- anchored to 12-inch o.c. securing One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max. inch crown x 1 -inch rafter with one each panel lap inch crown x 1-inch 0.072-inch diameter 24F-11 12-inch Wood leg staples in 1) min. 2.25- Wood leg staple spaced 8- finishing nail with min. 80/-90 diamond pattern inch x 7d ring One (1) min. 1.75-inch inch o.c. 3/16-inch head spaced spaced 16-inch o.c. shan k nail x 0.072-inch diameter 12-inch o.c. 24-inch o.c. finishing nail with min. 3/16-inch head spaced 4-inch o.c. One (1) 18 ga.1/4-inch crown x 1 -inch leg Nominal 1x2 staple spaced One (1) min. 1.5- No.2 SYP 12-inch o.c. securing One (1) 18 9 a. 114- One (1) min. 1.75-inch x Max. inch x I I ga. anchored to each panel lap inch crown x 1-inch 0.072-inch diameter 80124F-2 12-inch Wood smooth shank rafter with one Wood leg staple spaced 8- fin 'ishing nail with min 76.6 roofing nail spaced 1) 7d x 2.25- One (1) min. 1.75-inch inch o.c. 3/16-inch head spaced 16-inch o.c. inch ring shank x 0.072-inch diameter 12-inch o.c. nail 24-inch o.c. finishing nail with min. 3/16-inch head spaced 4-inch o.c. One (1) 18 ga.1/4-inch crown x 1 -inch leg Nominal 1x2 staple spaced No.2 SYP 12-inch o.c. securing One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max One (1) 14 ga. 5/8- anchored to each panel lap inch crown x 1 -inch 0.072-inch diameter 80/ 24F-3 12-inch Masonry inch long T nail rafter with one Wood leg staple spaced 8- finishing nail with min. 76.6spaced8-inch o.c. 1) 7d x 2.25- One (1) min. 1.75-inch inch o.c. 3/16-inch head spaced inch ring.shank x 0.072-inch diameter 12-inch o.c. nail 24-inch o.c. finishing nail with min. 3/16-inch head spaced 4-inch o.c. ALC15001.3 FL12194-R6 Page 5 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Apoendix A Approved Systems for 24-inch overhang with F-.Channel Wall onnecti on Center Connection Eave Connection System Panel . MDP No. Width pso substrate F-Channel Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga. 1/4-inch crown x 1-inch leg Nominal 1x2 staple securing the No.2 SYP nailer of each female Three (3) 18 ga.1/4- anchored to lock or spaced One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max. inch crown x 1 -inch rafter with one 16-inch o.c. securing inch crown x 1-inch 0.072-inch diameter 24F-4 16-inch Wood leg staples in 1) min. 2.25- each panel lap Wood leg staple spaced 8- finishing nail with min. 801-60 diamond pattern inch x 7d ring inch o.c. and securing 3/16-inch head spaced spaced 16-inch o.c. shank nail One (1) min. 1.75-inch each panel lap 16-inch o.c. 24-inch o.c. x 0.072-inch diameter finishing nail with min. 3/16-inch head spaced 4-inch o.c. One (1) 18 ga.1/4-inch crown x 1 -inch leg staple securing the Nominal 1x2 nailer of each female One (1) min. 1.5- No.2 SYP lock or spaced One (1) 18 ga. 1/4- One (1) min. 1.75-inch x inch x 11 ga. anchored to 16-inch o.c. securing inch crown x 1 -inch 0.072-inch diameter 24F-5 Max. Wood smooth shank rafter with one each panel lap Wood leg staple spaced 8- finishing nail with min. 80/-60 16-inch roofing nail spaced 1) 7d x 2.25- inch o.c. and securing 3/16-inch head spaced 16-inch o.c. inch ring shank One (1) min. 1,75-inch each panel lap 16-inch o.c. nail 24-inch o.c. x 0.072-inch diameter finishing nail with min. 3116-inch head spaced I I 4-inch o.c. ALC15001.3 FL12194-R6 Page 6 of 8 This evaluation report is provided f6r State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes. or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, ILLC ALUMINUM COILS, INC Soffits Apobndix A Approved Systems for 24-inch overhang with F-Channel Wall Connection, Center Connection Eave Connection System Panel MDP Width PsoNo. Substrate F-Channel Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga. 1/4-inch crown x 1-inch leg staple securing the Nominal 1x2 nailer of each female No.2 SYP lock or spaced One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max One (1) 14 ga. 5/8- anchored to 16-inch o.c. securing inch crown x 1 -inch 0.072-inch diameter 24F-6 16-inch Masonry inch long T nail rafter With one each panel lap Wood leg staple spaced 8- finishing nail with min. 80/-60 spaced 8-inch o.c. 1) 7d x 2.25- inch o,c. and securing 3/16-inch head spaced inch ring shank One (1) min. 1.75-inch each panel lap 16-inch o.c. nail 24-inch o.c. x 0.072-inch diameter finishing nail With min. 3/16-inch head spaced 4-inch o.c. ALC15001.3 FL12194-R6 Page 7 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply Warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Apj endix A Approved.Systems for 24-inch overhang with J-Channel Wall Connection Center Connection Eave Connection System Panel MDP No. Width Pso Batten J-Chan e Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachr -nent Nominal 1x2 No.2 SYP scabbed between rafters with One (1) 18 ga.1/4- one (1) min. 2.25- inch crown x 1 -inch Nominal 1x2 inch x 7d ring shank leg staple spaced No.2 SYP Three (3) 18 nail straight -nailed 12-inch o.c. anchored to ga.1/4-inch crown through the rafter securing each panel One (1) 18 ga. I/, One (1) min. 1.75-inch Max. rafter with one x 1 -inch leg into the end of the lap inch crown x 1 -inch x 0.072-inch diameter 24J-1 12-inch 1) min. 2 25- staples in diamond batten or two (2) Wood leg staple spaced finishing nail with min. 60 inch x 7d ring pattern spaced 16- min. 2.25-inch x 7d One (1) min. 1.75- 8-inch o.c. 3/16-inch head spaced shank nail inch o.c. ring shank nails toe- inch x 0.072-inch 12-inch o.c. 24-inch o.c. nailed on either side diameter finishing of the batten at nail with min. 3/16- each batten/rafter inch head spaced intersection. Max. 4-inch o.c. rafter spacing is 24-inch o.c. . Nominal 1x2 No.2 SYP scabbed One (1) 18 ga.114- between rafters with inch crown x 1 -inch one (1) min. 2.25- leg staple securing inch x 7d ring shank the nailer of eachNominal1x2 No.2 SYP Three (3) 18 nail straight -nailed female lock or One (1) 18 ga 1/4- anchored to ga.1/4-inch crown through the rafter spaced 16-inch o.c. inch crown x 1-'inch One (1) min. 1.75-inch Max. rafter with one x 1-inch leg into the end of the securing each panel leg staple spaced x 0 072-inch diameter 24J-2 16-inch 1) min. 2.25- staples in diamond batten or two (2) min. 2.25-inch x 7d lap Wood 8-inch o.c. and finishing nail with min. 3/16-inch head spaced 53.3 inch x 7d ring pattern spaced 16- ring shank nails toe- One (1) min. 1.75- securing each panel 16-inch o.c. shank nail inch o.c. nailed on either side inch x 0.072-inch lap 24-inch o.c. of the batten at diameter finishing each batten/rafter nail with min. 3116- intersection. Max. inch head spaced rafter spacing is 4-inch o.c. 24-inch o.c. I I I I ALC15001.3 FL12194-R6 Page 8 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ALUMINUM COILS, INCCREEKSoffits TECHNICAL SERVICES, LLC Appendix B INSTALLATION Note - Refer to the APPROVED SYSTEMS section of this report for additional installation details of a selected system and maximum design pressures limitations System No. Installation Detail Min. 3/0Y head dia. nail i'th mir). IA.! enigag.me.lit (for wo.3 substraLo) or nil-ri, 0.05711 dia, T or qttib null ith rdn. enga, mtffol -oncret ra. block sulstrat).,, spaced Lis no;d FASCIA SLIP BOARD FASCIA TRIM 12F-1 & SOFFIT (OVERHANG WIDTH VARIES) 12F 3 _-2'.F" CHANNEL v400d, C!.,ncr.ete r Block wall F—A STAOLE -SOFFIT TO FASCIA BOARD #T50 3/8" X 3/8" STAPLE 16" O'C' FASCIA LIP 114"J _ PAINTED S.S. 1 3/4" TRIM NAIL MIN. 5 NAILS PER 12' PIECE SOFFIT & FASCIA DETAIL ALC15001.3 FL12194-R6 Page I of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALLIMINUK/I COILS, INC Soffits Ap endix B System No. Installation Detail SOFFIT STAPLE OPEN RAFTER 11 Q1 MOND PATTERN 3/4" X 1/4" 1' DETAICROWNSTAPLES U SI) W TMO ) SING 9EMEEN A DIAMOND StAFLESrPATTERNFACIABOARD F' CHANNEL CAN BE INSTALLED WITH THE NAILING FLANGE UP OR DOWN WOOD SUBSTRATE CAP 3/4" X 1/4' CROWN STAPLE 'B" ON CENTER 1-3/4" TRIM NAM PAINTED S,S. 48" Olc SOFFIT"niak 12'-indh span 1-3/4' TRIM NAIL FACIA BOARD PAINTED S.S., 1 Air FASCIA CAP 3/4' X 1/4-' CROWN STAPLE SOFFIT....& FASO DETAIL ALC15001.3 FL12194-R6 Page 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,.or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, ILLC ALUMINUM COILS, INC Soffits ApIlendix B System No. Installation Detail.: OPEN RAFTER 3/0' NETWMN SOFFIT STAPLE OIST STWLrS j 1-1 DIAMOND . DETAIL PATTERUN FACIA BOARD _3/9' VENEENJ 3/+' X 1/4' CROWN STAPLE '24.' ON CENTER USING A DLW.OND PATTERN FASCIA CAP 12J-1 3/4' X 1/4- CROWN STAPLE *8" ON CENTER 1-3/4 TRIM NAIL FACIA BOARD CHANNEL 1-3/4' TRIM NAI PAINTED S.S. screwed to 6offit with ona(li 98 X PAINTED S.S. 48" FAS CIA CAP 3,011 dianjen r vcre-K 3/46 X 1/4' 1611 CROWN STAPLE SOFF(T—niax. 12-inch span 4 1 WOOD ORBLOCK SUBSTRATE OFFIT & FASCIA DETAIL ALC15001.3 FL12194-R6 Page 3 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC System No. I Installation Detail 16F-1 16F-5 S1 ALUMINUM COILS, INC Soffits Apo6ndix B I J" TRIM NAIL FASCIA BOARD PAINTED FASCIA CAP SOFFIT I-xj- CROWN STAPLE AFTER BOARD CAP; REFER FIT & FASCIA HAX. 16" SOFFIT & FASCIA DETAIL ALC15001.3 FL12194-R6 Page 4 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ALUMINUM COILS, INCCREEKSoffits TECHNICAL SERVICES, LLC Appendix B System No. Installation Detail . Min. 3/8" head dia, pail, with min. !,V' enq&gement (for Wood substrate) Or Min 0.097' diz i 'T-nail 'or stub jiail with (nin. 5/q" eng eta C-merit (flor corjcr etoi'- oi, bl acjc sul- a.te) rpaced as not above FASCIA SLIP BOARD FASCIA TRIM 16F-3 SOFFIT (OVERHANG WIDTH VARIES) F" CHANNEL, Wood, r Block Wall FA I / I r STAPLE SOFFIT TO FA CIA. BOARD #T50 3 /8 ' X 3/8" STAPLE 16" O.C. FASCIA LIP 1/4"-1/ PAINTED S.S. 1 3/4" TRIM NAII- AIN. 5 NAILS PER 12' PIECE SOFFIT & FASCIA DETAI ALCI5001.3 FL12194-R6 Page 5 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LILC ALUMINUM COILS, INC Soffits Apbendix B System No. Installation Detail SOFFIT STAPLE OPEN RAFTER DI MOND PATTERN 3/4" X 1/4* DETAIWNSTAPLESCROWNSTAPLES USING A DIAMOND 3/0' BETWMI PATTERN FACLA BOARD FASCIA CAP 16F-4 3/4- X 1/4' CROWN 1-3/4- TRIM NAIL FACIA BOARD 3/4- B.' STAPLE ON CENTER JT-RIMML I 'I1-3/4^ TRIM NAIL] PAINTED S.S. F' CHANNEL CAN HE . PAI NTED S,8 48' —FASCIA CAPINSTALLEDWITHTHEOIC* NAILING FLANGE UP 3/4' X 1/4 DOWN CROWN STAPLE sbFFIT max- 16-inch span 00" SOFFIT SUBSTRATE SCIFFIT &-EASCIA DETAIL ALC15001.3 FL12194-R6 Page 6 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not speclfically addressed herein. CREEK TECHNICAL SERVICES, LILC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail I TRIM NAIL FASCIA BOARD PAINT ED S S. FASCIA CAP I"XI" CROWN STAPLE U SING A PAT TEO N: 16F-2 & SOFFIII 16F- DIAMOND IF" CH) SUBSI AFTER BOARD, SOFFIT & FASCIA DETAIL CAP: REFER FIT L FASCIA 8 3/8 MAX. 16" SOFFIT STAPLE DIAMOND PATTERN ALC15001.3 FL12194-R6 Page 7 of 12 This evaluation report is provided for -State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. N & CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail. OPEN RAFTER SOFFIT STAPLE OIST ' I DIAMQN[2 ... PATTERN DETAI FACIA BOARD 310 3/4" X 1/4- CROWN STAPLE -24-, O,N CENTER USING A DIAMOND PATTERN FASCIA CAP I 16J-1 WOOD OR BLOCK SUBSTRATE 11-3/4! TRIM NAI PAINTED S.S. 48" D.C. SOFFIT—rnax. 16-inCli spall 3/4" X 1/4" CROWN 1-3/4" TRIM NAIL FACLA BOARD STAPLE W ON CENTER PAINTED S . S, I &r FASCIA CAP 3/4* X 1/4" CROWN STAPLE somT SOFFIT & FASCIA ULTAIL ALC15001.3 FL12194-R6 Page 8 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Ap endix B Systern No. Installation Detail I TRM NAIL FASCIA BOARD PAINTED S.S. 1,4.. CROWN I, --FASCIA CAP 5TAP LES USING A DIAMOND---\ SDFFIT- PATTERN: REFER TD SOFFIT STAPLE CROWN STAPLE DIAMOND PATTERN DETAIL, TR M NAIL FASCIA BOARD PAINTED S.S; A SOFFIT FASCIA DETAIL 24F-1 & 24F-4 1"4" ER OWN STAPLE "\— FASCIA CAP, REFER TO SOFFIT FASCIA DETAIL 0 Nominal SYP —I— Batten Anchored to 3/8'\ SOFFIT; MAX, 24" F-CHA14NEL Rafters with one 7d Ping Shank Nall at WOOD SUBSTRATE — every Rafter SOFFIT STAPLE DIAMONO PATTERN ALC15001.3 FL12194-R6 Page 9 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, ILLC ALUMINUM COILS, INC Soffits Ap , endix B System No. Installation Detail I TRIM NAIL FASCIA BOARD PAINTED S,S 1.1' SMOOTH SHANK ROOF HAI 5 FASCIA CAP T 1",,I' CROWN STAPLE I TRIM N AIL FASCIA, BOARD PAINTED S.S. A SOFFIT FASCIA 24F-2 & DETAIL 24F-5 CROWN STAPLE FASCIA CAP: REFER TO SOFFIT & FASCIA DETAIL Nominal t'X2- 5yp batten Anc6rod to SOFFIT; MAX. 24'! F-CHANNEL Rafters with one Id Ring Shank Nail at every Rafter WOOD SUBSTRATE- ALC15001.3 FL12194-R6 Page 10 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits ApiYendix B System No. Installation Detail I J" TRIM NAIL FASCIA BOARD PAINTED S S,—\ 146A T-IIAILS FASCIA CAP SOFFIT— CROWN STAPLE 1 TRIM NAIL FASCIA BOARD PAINTED SS. A SOFFIT FASCIA 24F-3 & DETAIL 24F-6 V'Xqj CROWN STAPL FASCIA CAP; REFER TO SOFFIT & FASCIA DETAIL Nominal I"x2",SYP -A P-CHANNEL Batten Anchored to SOFFIT; MAX. 2.4" Rafters with one ?d Ring Shank Nail at every Rafter MASONRY— ALC15001.3 FL12194-R6 Page 11 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. iCREEKll" TECHNICAL SERVIcEs, LLC ALUMINUM COILS, INC Soffits Apf endix B System No. installation Detail I I' TRIM NAIL. FASCIA BOARD PAINTED S.S V'J* CROWN FASCIA CAP STAPLES SOFFIT U5145 A DIAMOND PATTERN; REFER TO CANTILEVERED VXj- CROWN STAPLE SOFFIT STAPLE RAFTER 01 AMOND PATTERN DETAIL FASCIA BOARD SOFFIT FASCIA I TRI AIL F AINTED S , S DETAIL 24J-1 & 1-4" CROWN STAPLE FASCIA24J-2 CAP; REFER L FASCIA DETAIL Nornnall"x2'SYP battens scabired between rafters and SOFFIT; MAX, 24" I-CHAMEL secured with one 1) 7d ring shank nail stralgh -nailed in ugh Ilia rafter into the end WOOD SUBSTRATE- Irtche batten a, Iwo (2) Id ng sl iank nails toe -nailed on either side of the hattern at the b2ftenhaner Intemoclion OFFIT STAPLE DIAMOND PATTERN ALC15001.3 FL12194-R6 Page 12 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CR-EEK TECHNICAL SERVIcEs, LLC DESIGN WIND LOADS ALUMINUM COILS, INC Soffits Aporendix C The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-10 under the following provisions: 1 . Wind speeds for risk category 1, 11, 111, and IV buildings shall be as defined in Section 1609 of the FBC. 2. Exposure B, C, and D shall be as defined in section 1609 of the FBC. 3. Design wind loads are provided only for walls/soff its with a mean roof height less than or equal to 60-ft. 4. All calculations are based on an effective wind area of 1 O_ft2 or less. 5. Topographic factors such as escarpments or hills have,been excluded from the analysis. 6. Wind directionality factor, Kd = 0.85 7. V,,It is shown in the tables below. Design pressures are multiplied by 0.6 in accordance with Section 1609.1.3 of the FBC. 8. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional. 9. Zones 4 and 5 shall be defined as shown below. Dimension "a" shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever is smaller,, but not less tl-ian either 4% of the least horizontal dimension or 3-ft. ALC15001.3 FL12194-R6 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Serviced, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK . TECHNICAL SERVICES, U-C ALUMINUM COILS, INC Soffits Appendix C 1A 2 WAR Baisid W ind!Sbbe' x` m-0 41 A 4 M M i", wzo';'- 0"' ;e I n . .? n T, 1 7. 0 ii" op" R,5,160WE` Wdi 20 16.9 19.8 22.9 26.3 30.0 33.8 37.9 42.2 46.8 25 16.9 19.8 22.9 26.3 30.0 33.8 37.9 42.2 46.8 30 16.9 19.8 22.9 26.3 30.0 33.8 37.9 42.2 46.8 4 40 18.3 21.5 24.9 28.6 32.5 36.7 41.2 45.9 50.8 50 19.5 22.9 26.5 30.5 34.7 39.1 43.9 48.9 54.1 Enclosed 60 20.5 24.0 27.8 32.0 36.4 41.1 46.0 51.3 56.8 Negative 20 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 Loads) 25 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 30 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 5 40 22.6 26.5 30.7 35.3 40.1 45.3 50.8 56.6 62.7 50 24.1 28.2 32.8 37.6 42.8 48.3 54.1 60.3 66.8 1-1 60 25.3 29.6 34.4 39.5 44.9 50.7 56.8 63.3 70.1 20 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 25 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 30 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 4 40 11.7 13.8 16.0 18.3 20.8 23.5 26.4 29.4 32.5 50 12.5 14.7 17.0 19.5 22.2 25.1 28.1 31.3 34.7 Enclosed 60 13.1 15.4 17.8 20.5 23.3 26.3 29.5 32.9 36.4 Positive 20 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 Loads) 25 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 30 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 5 40 11.7 13.8 16.0 18.3 20.8 23.5 26.4 29.4 32.5 50 12.5 14.7 17.0 19.5 22.2 25.1 28.1 31.3 34.7 60 13.1 15.4 17.8 20.5 1 23.3 1 26.3 29.5 32.9 1 36.4 ALC15001.3 FL12194-R6 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Apoendix C W::06"'Sbffi n'.,x sure: MP%5690, 1 - 7777" BUlldlng- e' 'X W Basib'W S clInd"._ P 15' 120 0 fau 7L, N 20 21.7 25.4 29.5 33.8 38.5 43.5 48.7 54.3, 60.2 25 22.6 26.6 30.8 35.4 40.2 45.4 50.9 56.7 62.8 30 23.6 27.7 32.1 36.9 41,9 47.3 53.1 59.1 65.5 4 40 25.0 29.4 34.1 39.1 44.5 50.2 56.3 1 62.7 69.5 50 26.2 30.8 35.7 41.0 46.6 52.6 59.0 65.8 72.9 Enclosed 60 27.2 31.9 37.0 42.5 48.3 54.6 61.2 68.2 75.5 Negative Loads) 20 26.7 31.4 36.4 41.8 47.5 53.7 60.2 67.0 74.3 25 27.9 32.8 38.0 43.6 49.6 56.0 62.8 70.0 77.6 30 29.1 34.2 39.6 45.5 51.8 58.4 65.5 73.0 80.9 5 40 30.9 36.3 42.1 48.3 54.9 62.0 69.5 77.5 85.8 50 32.4 38.0 44.1 50.6 57.6 65.0 72.9 81.2 89.9 60 33.6 39.4 45.7 52.5 59.7 67.4 75.5 84.2 93.2 20 13.9 16.3 18.9 21.7 24.7 27.9 31.2 34.8 38.5 25 14.5 17.0 19.7 22.6 25.8 29.1 32.6 36.3 40.3 30 15.1 17.7 20.6 23.6 26.9 30.3 34.0 37.9 42.0 4 40 16.0 18.8 21 8 25.1 28.5 32.2 36.1 40.2 44.5 50 16.8 19.7 22.9 26.3 29.9 33.7 37.8 42.1 46.7 Enclosed 60 17.4 20.5 23.7 27.2 31.0 35.0 39.2 43.7 48.4 Positive Loads) 20 13.9 16.3 18.9 21.7 24.7 27.9 31.2 34.8 38.5 25 14.5 17.0 19.7 22.6 25.8 29.1 32.6 36.3 40.3 30 15.1 17.7 20.6 23.6 26.9 30.3 34.0 37.9 42.0 5 40 16.0 18.8 21.8 25.1 28.5 32.2 36.1 40.2 44.5 50 16.8 19.7 22.9 26.3 29.9 33.7 37.8 42.1 46.7 60 17.4 20.5 23.7 27.2 31.0 35.0 39.2 43.7 48.4 ALC15001.3 FL12194-R6 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CR-EEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Ap6endix C Fi A.- id' Q 6iW B` i,f asjc,'V_:ir), 06 d 'hP, :mp 20 26.0 30.5 35.4 40.6 46.2 52.2 58.5 65.2 72.2 25 27.0 31.6 36.7 42.1 47.9 54.1 60.6 67.6 74.9 30 27.9 32.8 38.0 43.6 49.6 56.0 62.8 70.0 77.5 4 40 29.4 34.5 40.0 45.9 52.2 58.9 66.1 73.6 81.6 50 30.6 35.9 41.6 47.8 54.3 61.3 68.8 76.6 84.9 Enclosed 60 31.5 37.0 42.9 49.3 56.1 63.3 70.9 79.0 87.6 Negative Loads) 20 32.1 37.7 43.7 50.1 57.0 64.4 72.2 80.4 89.1 25 33.3 39.1 45.3 52.0 59.2 66.8 74.9 83.4 92.4 30 34.5 40.4 46.9 53.8 61.3 69.2 77.5 86.4 95.7 5 40 36.2 42.5 49.3 56.6 64.4 72.7 81.5 90.9 100.7 50 37.7 44.3 51.4 58.9 67.1 75.7 84.9 94.6 104.8 60 38.9 45.7 53.0 60.8 69.2 78.1 87.6 97.6 108.1 20 16.7 19.5 22.7 26.0 29.6 33.4 37.5 41.7 46.3 25 17.3 20.3 23.5 27.0 30.7 34.7 38.9 43.3 48.0 30 17.9 21.0 24.3 27.9 31.8 35.9 40.2 44.8 49.7 4 40 18.8 22.1 25.6 29.4 33.4 37.8 42.3 47.2 52.2 50 19.6 23.0 26.7 30.6 34.8 39.3 44.1 49.1 54,4 Enclosed 60 20.2 23.7 27.5 31.6 35.9 40.5 45.4 50.6 56.1 Positive Loads) 20 16.7 19.5 22.7 26.0 29.6 33.4 37.5 41.7 46.3 25 17.3 20.3 23.5 27.0 30.7 34.7 38.9 43.3 48.0 30 17.9 21.0 24.3 27.9 31.8 35.9 40.2 44.8 49.7 5 4 18.8 22.1 25.6 29.4 33.4 37.8 42.3 47.2 52.2 50 19.6 23.0 26.7 30.6 34.8 39.3 44.1 49.1 54.4 60 20.2 23.7 27.5 31.6 35.9 40.5 45.4 50.6 56.1 ALC15001.3 FL12194-R6 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 3/8" F-Channell 3/8" J-Channel ALC15001.3 3/8" — 3/4" --- 8" HEM 1 T 7 3/4" 3/8" FL12194-R6 ISOMETRIC VIEW 3/8" PROFILE ISOMETRIC VIEW 318" PROFILE ALUMINUM COILS, INC Soffits Apoendix D Page 1of4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Fascia CREEK TECHNICAL SERVICES, LLC 1/8" HEM 5 3/4" 7/8" " 6"FASCIA 7" BLANK 1/4" ISOMETRIC VIEW ALUMINUM COILS, INC Soffits Apoendix D ALC15001.3 FL12194-R6 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVItEs, LLC 16" Q4 Soffit 01=-, 0. 1 2V TYP 6: OROFILE' 2. 175' REP ALUMINUM COILS, INC Soffits Apobndix D ALC15001.3 FL12194-R6 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 12" T4 Soffit LiL4 314j- 7 11/811 . 1 7/8"- 1- 13, 1/8" - 1/2" 11r2" 1/2" 1/2" 1/21' r 1/81, 3/8" 0.125, ryp 13.75" BLANK 3/8" PROFILE I I TV RE F END OF REPORT ALUMINUM COILS, INC Soffits Ap endix D ALC15001.3 FL12194-R6 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installa,tion, recommended use, or other product attributes that are not specifically addressed herein. Florida Building Code Online Page I of 3 h"i_fAQMMI_ 0,; -gI4MAN, 9Mig 2 -' -11 - =3 BCIS Home i Log In User kegistration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search r 77' x Product ApprovalrUSER: Public Usera Product Approval Menu > Product or ADDliCation 5earch > Application Lis > Application Detail FL # FL7006-RlO Application I ype Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By IKO Industries, Ltd 40 Hansen Road South Brampton, NON -US L6W 3H4 708) 496-2800 Ext 200 rmetzOO1@tampabay.rr.com Robert Metz rmetzOO1@tampabay.rr.com Bob Metz REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 727) 776-5261 rmetzOOI@tampabay.rr.com Don Shaw IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 717) 579-6706 don.shaw@iko.com Roofing Asphalt Shingles Certification Mark or Listing FM Approvals - CER Locke Bowden R Validation Checklist - Hardcopy Received Standard ASTM D3161 modified to 110 mph ASTM D3462 ASTM D7158 Class H ASTM E108 Year 2016 2010 2011 2011 https://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wGEVXQwtDqse7mYBd2b' )K... 2/6/2018 Florida Building Code Online Page 2 of 3 Product Approval Method Method I Option A Date Submitted 10/08/2017 Date Validated 10/30/2017 Date Pending FBC Approval Date Approved 11/01/2017 Summary of Products FL # Model, Number or Name Description 7006.1 Cambridge, Cambridge HD, Laminated architectural fiberglass asphalt shingle Biltmore and Biltmore HD manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.; Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL7006 R10 C CAC Letter - ASTM D3161 letter - (9-26- 2017) from FM.odfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL7006 R10 C CAC Letter - ASTM D3462 letter - (9-26- 2017).r)dDesignPressure: N/A Other: FL7006 R10 C CAC Letter - ASTM E108 letter - (9-26- 2LQIZ)—P ff Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 R10 II IKO-187-02-01 Letter - Installation Instructions for FBC FL7006.lpd Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.2 Hip and Ridge 12 Cap This is a 12" x 12" fiberglass asphalt shingle used to cover the hip and/or ridge of an asphalt shingle roof system manufactured at IKO's Kankakee, IL, Toronto, Ont. and Brampton, Ontario plants. Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL7006 R10 C CAC ASTM D 3462 - Shingle lette Surveillanj e Audit Location - 6-2 -ZO 7 2ff8L __L_)_ Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7006 R10 C CAC Letter - ASTM D3161 letter - (9-26- 2017) from FM.pdfDesignPressure: N/A Other- FL7006 R10 C CAC Letter - ASTM D3462 letter - (9-26- 2017).[)d FL7006 R10 C CAC Letter - ASTM E108 letter - (9-26- 2017).pd Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 R10 11 Hip and Ridge Cap Shing. e Installation Instructions. pd FL7006 RIO II IKO-187-02-01 Letter - Installation Instructions for FBC 171-7006 pd Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.3 Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at Starter Strip the bottom of a roof system manufactured in Brampton and Hawkesbury, Ontario plants Limits of Use Certification Agency Certificate Approved for-use-in-HVHZ: Yes FL7006 R10 C CAC Letter - ASTM D316, letter - (9-26- 20.1.Z)_from FM pffApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A FL7006 P,10 C CAC Letter - ASTM D3462 letter - (9-26- 2017).DdDesignPressure: N/A Other: FL7006 RIO C CAC Letter - ASTM E108 letter - (9-26- 2017).pd Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 R10 11 IKO-187-02-01 Letter - Installation Instructions for FBC FL7006.pd FL7006 R10 11 Roofing-Products-Leading-Edge-Plus- Aoolhcation-ENW.ndf Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: https://www.floridabuilding.org/pr/Pr_app_dtl.aspx?param=wGEVXQwtDqse7mYBd2b3K... 2/6/2018 Florida Building Code Online Page 3 of 3 7006.4 Marathon Plus AR, Superglass Plus AR Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 3 tab fiberglass asphalt shingle manufactured at IKO's Brampton, Ontario, Hawkesbury Ont., Toronto, Ont.; Sylacauga, AL and Kanakakee, IL plants Certification Agency Certificate FL7006 R10 C CAC Letter - ASTM D3161 letter - (9-76- 2017) from FM.pd FL7006 RIO C CAC Letter - ASTM D3462 letter - (9-26 2017).pd FL7006 R10 C CAC Letter - ASTM E108 letter - 9-2- 2017).od Quality Assurance Contract Expiration Date 12/20/2020 Installation Instructions FL7006 R10 II IKO-187-02-01 Letter - installation Instructions for FBC FL7006.r)d Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: F.a FN..I] Contact Us :: 2601 Blair Store Road, Tallahassee FL 32399 Phone: 850-487-182 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida, :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electro hic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 8SO.487. 1395. -Pursuarit to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Pinoduct Apprcr,ral Accepts: M W @01 E 0 https://wivw.floridabuilding.org/pr/pr — app_dtl.aspx?param=wGEVXQwtDqse7mYBd2b3K... 2/6/2018 7, Ali IIIIIIIIIII T E C H N 0 L 0 G I E S October 27, 2017 IKO Industries, Ltd 120 Hay Rd. Wilmington, DE 19809 Re: FBC FL7006 Sir(s), PRI Construction Materials Technologies has completed a technical review and attached sealed shingle instructions in compliance the 2017 Florida Building Code. This review was completed based on the receipt of following evidence from IKO Industries, Ltd: 1 ) IKO Shingle Application Instructions — 3-Tab Shingles EN-3Tab — Appins-8AGXEFS-2012-1 1—reformatted 2013-02-revO7/13-Florida) 2) IKO Laminated Shingles Application Instructions EN -Laminated — Appins_8TTEFS-2012-04—reformatted 2013-02-revO7/13-Florida) 3) IKO Hip and Ridge 12 Application Instructions EN-H ipa in d Ridge 1 2_31-1 RTri-201 3-08—reform atted 2013-08) 4) IKO Leading Edge Plus Shingle Application Instructions EN-3LEP-Tri-2012-06 — reformatted 2013-03) 5) ASTM D3161 Test Report(FM Approvals Project No. 3040947) The attached instructions should be used in conjunction with the published manufacturer's application instructions and applicable code. In the event the instructions conflict, these instructions shall govern. Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. Signed: Signed: Brad GrzyboA(ski Duc T.MidyY2L Managing Director Florida Regzt—er—ed —Kofessional ErI P.E. Number: 65034 Date: October 27, 2017 Date: October 27, 2017 Attachments: A) IKO Shingle Application Instructions - 3-Tab B) IKO Laminated Shingles Application Instructions C) IKO Hip and Ridge 12 Application Instructions D) IKO Leading Edge Plus Application Instructions IKO-1 87-02-01 PRI Construction Materials Technologies, -I-C. 6412 Badger Drive Tampa, FIL 33610 Tel: 813-621-57T7 Fax: 813-621-5840 e-mail: matedaistesting@pricmt.com WebSite: http:1twww.pricmtcorn IKQ Installation Instructions for Asphalt Shingles Page 2 of 5 11<0 Shingle Application. Instructions — 3-Tab Shingles ASTM D3161, Class F — IKO Marathon 25 AR and CRC Superglass M25AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough to penetrate through plywood or 3/4" irito boards. Use 4 nails per shingle placed 6-1/8" above the butt edge, approx. 1 " and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAI LING ON STEEP SLOPES: For steep slopes of 21 " per foot (60') or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1 " diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8". STEEP SLOPES SEAUNG STRIP 61118- 4 NAMUSNILS DO NOT NAIL INTO OR ABOVE THE SEALING STRIP PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: matedalstesting@pricmt.com WebSite: http:/Awjw.pdcmtcom IKO Installation Instructions for Asphalt Shingles Page 3 of 5 IKO Laminated Shingles Application Instructions ASTIVI D3161, Class F — Cambridge, Cambridge HID, and CRC Biltmo-re AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed in the nail line 7-3/8" below the top edge, approx. 1 " and 13" in from each end. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21 " per foot (60') or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1 " diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should sea] to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8". 63 NAIL LINE NAILING - STEEP SLOPES APPLICATION Use. six nails as shovov CEMENT PROPER APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OF THE SHINGLE PRI Construction Materials Technologies, LLC. &412BadgerDdve Tampa,FL33610 Tel:813-621-5777 Fax:813-621-5840 e-mail: matehaistesting@pricmt.com WebSite:http:/Mww.pricmt.Gorn IKO Installation Instructions for Asphalt Shingles Page 4 of 5 IKO Hip and Ridge 12 Application Instructions ASTM D3161, Class F — IKO Hip and Ridge 12) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. Cut hip and ridge shingles into thirds, using.the perforation marks as a cutting guide. These shingles are designed for a 5 1/8" (130 mm) exposure. (For a neater appearance, the top of each side of each piece has been factory trimmed on a 1 " (25 mm) taper (see drawing). Bend each piece over the hip or ridge, and nail 5 5/8" (143 mm) above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 1/8"(130 mm). Apply hip pieces starting at the lower end of the hip, working up toward the ridge. On hip roofs, apply ridge pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end opposite to the prevailing wind direction and continue. to the other end. Note: To obtain a three-dimensional effect, (which is recommended, but not required), apply hip and ridge shingles double thickness by stacking 2 pieces on top of one another, the lower piece extending about 3/4" (19 mm) further than the top piece (see diagram). The final shingle should be set in cement, and the exposed nail heads of the final shingle should be covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for easier bending. NOTE: 8HINGLES MUST BE APPLIED PROPERLY. THEYARE DESIGNED FOR USE AS HIP AND RIDGE SHINGLES ONLY, AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS. REVIEW ALL APPLICABLE BUILDING CODES, MINIMUM PROPERTY STANDARDS, AND REQUIREMENTS PRIOR TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. 11 M10 TAPM CUT PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: matehaistesting@pdcmt.com WebSite: htLp:/A&ww.pdcmt.com IKO Installation Instructions for Asphalt Shingles Page 5 of 5 IKO Leading Edge Plus Application Instructions ASTM D3161, Class F — IKO Leading Edge Plus) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. 1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required 2. Each 39 3/8" x 13 1/4" (1000 mrn x 336 mm) IKO Leading Edge Plus strip is perforated lengthwise for separation into two (2) shingles. Take one I KO Leading Edge Plus strip and fold flat at perforation to separate. 3. Take one of the separated shingles 39 3/8" x 6 5/8" (1000 mm x,168 mm) and remove approximately 20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up, with the factory installed sealant adjacent to the eaves. The shingle should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge and 1" (25 mm) in from each end. 4. Take the leftover 20" (500 mm) piece shingle. Rotate the piece and align it vertically up the rake edge with the factory installed sealant adjacent to the outer edge of the roof. The shingle should overhang the rake edge by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with fasteners located 3" to 4" (75 mm to 100 mm) from the rake edge and 1 " (25 mm) in from each end. 5. Repeat Steps 3 — 4 for the right lower corner of the roof deck. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" (9 mm) diameter heads, long enough to penetrate through plywood or 3/4" (20 mm) into boards. Use 4 nails per shingle placed 3" to 4" (75 mm to 100 mm from the eave edge and approximately 1 " and 13" (25 mm and 330 mm) in from each end. 6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck. Install the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingles to the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge, 4 nails per shingle. 7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first -course field shingles and help keep them from lifting in high winds. PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: matefialstesfing@p6cmt.com WebSite: hftp:/Ahfww.p cmt.com Florida Buildinc, Code Online Page I of 2 Ln Klt - BCISHome LogIn User Registration HotTopics SubmitSurcharge Stats&Facts Publications FBCStaff BCISSite Map Links Search 'I i pprovalgagM.P.ro.Vo Userdbr ((i - TV Product Approval Menu > Product or Agolication Search > Application Lis > Application Detail F # FL15216-R3 All Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer InterWrap, Inc. Address/Phone/Email 32923 Mission Way Mission, NON -US 00000 551) 574-2939 mtupas@interwrap.com Authorized Signature Eduardo Lozano elozano@interwrap.com Technical Representative Eduardo Lozano Address/Phone/Email 32923 Mission Way Mission, NON -US 00000 778) 945-2891 elozano@interwrap.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Ej. Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 09/30/2019 Validated By John W. Knezevich, PE M Validation Checklist - Hardcopy Received Certificate of Independence FL15216 R3 COI 2017 01 COI Nieminen.ndf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Standard Year ASTM D1970 (tear) 2015 ASTM D226 (physicals) 2009 https://www.floridabuilding.org/pr/p_app_dtt.aspx?param=wGEVXQwtDqv")yVVKJZ IQ... 2/6/2018 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method I Option D 10/10/2017 10/11/2017 10/15/2017 12/12/2017 FL # Model, Number or Name Description 15216.1 RhinoRoof Underlayments Synthetic roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL15216 R3 11 2017 10 FINAL ER INTERWRAP RHINOROOF FL15216- R3.pdApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: See ER Section 5 for Limits of Use. Evaluation Reports FL15216 R3 AE 2017 10 FINAL ER INTERWRAP RHINOROOF FL15216- R3.pdf Created by Independent Third Party: Yes F .7- Fl __ Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone, 850-487-182 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statemen :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuantto Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The ernails provided may be used for official communication with the licensee. Ho.ever email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: W Fol RE 0 cri d ra.rd 11 Safe https://www.floridabuilding.org/pr/pr--anp_dtl.aspx?pararn=wGEVXQwtDqv3yVVKJZ l Q... 2/6/2018 k 1TRINITY ERD EVALUATION REPORT Interwrap, Inc. 32923 Mission Way Mission, BC V2V-6E4 Canada 551) 574-2939 EXTERIOR RESEARCH & DESIGN, LLC. Certificote of Authorizotion #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 140510.02.12-R3 FI-15216-113 Date of Issuance: 02/17/2012 Revision 3: 10/10/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6t' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: RhinoRoof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3. Prepared by: Robert J.M. Nielminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/10/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are -being issued. 4.. Robert Nieminen, P.E. does not have, nor will acquire a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 1 TRINITY! ERD ROOFING COMPONENT EVALUATION: I., SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: RhinoRoof Underlayments, as produced by Interwrap, Inc., has demonstrated compliance with the following sections of the 6 th Edition (2017) Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Properties Standard Year 1507.1.1, T1507.1.1 Unrolling, Breaking Strength, Pliability ASTIVI D226 2009 1507.1.1 Tear Strength ASTIVI D1970 2015 3. REFERENCES: Enfty Examination Reference Date ITS(TST1S09) Physical Properties 100539395COG-006 10/27/2011 ITS(TST1509) Physical Properties 10053939SCOQ-002 10/27/2011 ITS(TST1S09) Physical Properties 100539395COQ-006 03/14/2014 PRI (TSTS878) ASTIVI D1970; Tear strength OCF-330-02-02 10/03/2017 ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 4. PRODUCT DESCRIPTION: 4.1 RhinoRoof U20 is a multilayered polymer woven coated synthetic roof underlayment available in 42-inch wide rolls, and can be produced in various other sizes; meets FBC 1507.1.1 (Exception). 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 RhinoRoof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: 1 R' L 'E 1 Asphalt Wood Shakes Slate or Underlayment Shingles Nail -On Tile Foam -On Tile Metal Shingles Simulated Slate RhinoRoof U20 5.6 Exposure Limitations: RhinoRoof U20 shall not be left exposed for longer than 30-days after installation. Exterior Research and Design, LLC. Evaluation Report 140510.02.12-R3 Certificate of Authori2otion #9503 6 T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.15216-113 RhinoRoof Underlayments Revision 3: 10/10/2017 Page 2 of 3 TRINITY'ERD 6. INSTALLATION: 6.1 RhinoRoof Underlayments shall be installed in accordance with Interwrap, Inc. published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 63", 6.3.1 Shall be installed in compliance with the requirements for ASTIM D226, Type I or 11 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet - width for double -layer applications. 6.3.1 Fasteners: For exposure < 24 hours, corrosion resistant fasteners may be 1-inch roofing nails with a.3/8-inch diameter head, or those noted in 6.4.2. The use of staples is prohibited. For exposure > 24 hours up to maximum 30 days, corrosion resistant fasteners shall be minimum 1-inch diameter plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough edge facing up). The use of staples is prohibited. 6.3.2 Single Layer; Roof Slope > 4:12: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. Refer to Interwrap, Inc. recommendations for alternate lap configurations and/or the use of sealant under certain conditions. For exposure < 24 hours, use of every -other fastening location printed on the surface is acceptable. For exposure > 24 hours up to maximum 30-days, use of every fastening location printed on the surface is required. When batten systems are to be installed atop the underlayment, the underlayment need only be prelimin'arily attached pending attachment of the battens on the same day. Battens shall not be positioned over cap nails. If this occurs, remove the cap nail and patch the hole in accordance with Interwrap published instructions. 6.4.3 Double Layers 2:12 < Roof Slope < 4:12: End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum half -sheet-width plus 1-inch. Double layer application; begin by fastening a half -width plus 1-inch starter strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.5, but maintaining minimum half -width plus 1-inch side (horizontal) laps, resulting in a double -layer application. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Qingdao, China 9. QUALITY ASSURANCE ENTITY: Intertek Testing Services NA Inc. — QUA1673; (608) 836-4400 END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 140510.02.12-R3 Certificate ofAuthorizotion #9503 6 T" EDITION (2017) F8C NON-HVH2 EVALUATION FLIS216-R3 RhinoRoof Underlayments Revision 3: 10/10/2017 Page 3 of 3 C-1Synthietic Roofing Underlayrnent RhinoRoof' U20 Installation Instructions RhinoRoof' U20 is an air, water and vapor barrier and therefore must be installed above a properly ventilated space(s). Follow ALL building codes applicable to your geographical region and structure type as it is considered a vapor barrier. DECK PREP: Protrusions from the deck area must be removed and decks shall have no voids, damaged or unsupported areas. Deck surface should be free of debris, dry and moisture free. USE: RhinoRoof* U20 must be covered by primary roofing within 60 days of application. U20 is designed for use under; asphalt or synthetic shingles, metal in residential applications, and cedar shakes that have been primed. APPLICATION: For slopes from 4:12 and higher RhinoRoof' U20 is to be laid out horizontally (parallel) to the eave with the printed side up. Horizontal laps should be 4" and Vertical laps should be 6"and anchored approximately 1 " in from the edge. For low slope applications it is recommended to overlap 50% plus 1 ", for complete definition of low slope and guidelines consult authorities having jurisdiction. U20 product is not recommended for slopes less than 2:12. The use of roofing hammer, pneumatic air or gas driven fastener tools is acceptable. The use of straight edge cutting knives is recommended. FASTENERS: For same day coverage with primary roofing RhinoRoof* U20 can be anchored with corrosive resistant 3/8" head x 1" leg roofing nails (ring shank preferred, smooth leg acceptable). The use of every other anchoring location printed on the product is also acceptable. If U20 will be left exposed for Op to 60 days the product must be anchored with 1 " plastic or metal cap smooth or ring shank roofing nails and anchored in all locations printed on the facer. DO NOT USE STAPLES: the use of staples to penetrate RhinoRoof* U20 will void warranty. ANCHORING: All anchoring nails must be flush, 90 degrees to the roof deck, and tight with the underlayment surface and the structural roof deck. Where seams and joints require sealant or adhesive use a low solvent plastic roofing cement meeting ASTM D-4586 Type 1, or Federal Spec SS-153 Type 1 such as Karnak, Henry, DAP, MB, Geocel or equivalent. Acceptable alternatives are butyl rubber, urethane, and EDPM based caulk or tape sealant. EXTENDED EXPOSURE: If RhinoRoof' U20 product will be exposed longer than 24 hours and up to 60 days then product must be attached to the structural roof deck using a minimum 1 " diameter plastic or metal cap roofing nails (ring shank preferred but smooth leg acceptable). Miami Dade approved tin tags/metal caps are also acceptable, and it is recommended for best performance to use with the rough edge facing up. For extended exposure it is always recommended to anchor on every printed position on the facer. RhinoRoof' U20 is not designed for indefinite outdoor exposure. For extended exposure conditions where driving rain or strong winds are expected it is recommended to take additional precautions such as doubling the lap widths. Alternately or in addition to a compatible sealant could be used between the laps or a peel and stick tape could be applied to the overlaps. CAUTION - READ GOOD SAFETY PRACTICES BELOW Good safety practices should be followed on steep slope roofs, such as use of tie -offs, toe boards, ladders and/or safety ropes and personal body harnesses. Follow OSHA guidelines. Slip resistance may vary with surface conditions from debris that accumulates, weather, footwear and roof pitch. Failure to use proper safety gear can result in serious injury. Depending on roof pitch and surface conditions, blocking may be retIuired to support materials on the roof and is good safety practice. Remember to seal the nail holes after removing blocking. InterWrap" Roofing Products Divisioni ! . hL Charleston, SC - Vancouver, BC - Mission, BC - Montr6al, OC MEMBER Web: www.InterWrap.com/roofing I E-mail: info@interwrap.com Toll Free: 888 713 7663 1 Tel: 778 945 2888 Florida Building Code Online Page 1 of 2 1 WIN- BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public UseribXprW Product Approval Menu > Product or ADDlication Search > Application Lis > Application Detail FL # FL16994-R5 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Southeastern Metals Mfg. Co. Address/Phone/Email 11801 Industry Drive Jacksonville, FL 32218 904) 696-4682 jhkelsey@semetals.com Authorized Signature Jeremy Kelsey jhkelsey@semetals.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a.Florida Registered Architect or a Licensed Florida Professional Engineer C Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/20/2020 Validated By Locke Bowden JR Validation Checklist - Hardcopy Received Certificate of Independence FL16994 R5 COI SEM14001.5a 2017 FBC Eval Report Off -Ridge Vent final.pc1 Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1503.5 1709.2 Product Approval Method Method 2 Option B I https://www.floridabuilding.org/p-r./Dr p dtl.aspx?param=wGEVXQwtDqvBwYu9TrZN... 2/6/2018ap Florida Building Code Online Page 2 of 2 Date Submitted 09/26/2017 Date Validated 10/10/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 16994.1 Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL16994 R5 II SEM14001.5a 2017 FBC Eval Report Off - Ridge Vent final.QdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-18 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL16994 R5 AE SEM14001.5a 2017 FBC Eval Report Off - Ridge Vent final.od Created by Independent Third Party: Yes 16994.2 __Tle Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with clay or concrete tile Limits of Use Installation Instructions Approved for use in HVHZ: No FL16994 R5 II SEM14001.51b 2017 FBC Eval Report Tile Roof Vent firLal pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-9 Created by Independent Third Party: Yes Other: See Evaluation Report for limits of use. Evaluation Reports FL16994 R5 AE SEM14001.5b 2017 FBC Eval Report Tile Roof Vent final. pd Created by Independent Third Party: Yes Fack] Fl-_-t Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone, 850-487-182 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statemen :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a pubiic-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here.. Product Approval Accepts: M go 99 9a IM https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvBwYu9TrZN... 2/6/2018 Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6'" EDITION (2017) Manufacturer: Southeastern Metals Manufacturing Co., Inc. (SEMCO) Issued October 10, 2017 11801 Industry Drive Jacksonville, FIL 32218 800) 874-0335 http://www.semetals.com Manufacturing Plant: Jacksonville, FIL Quality Assurance: UL LLC (QUA1743) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1503.5, 1709.2 Properties: Roof Ventilation REFERENCES EniL Report No. Standard Year PRI Construction Materials Technologies TST5878) SEM-029-02-01 ASTM E 330 2014 PRI Construction Materials Technologies TST5878) SEM-031-02-01 ASTM E 330 2014 Zachary R. Priest, P.E. (CREEK Technical Services) SEM14003 Calculations 2014 PRODUCT DESCRIPTION Off Ridge Vent: Minimum 26 ga. ASTM A792 or ASTM A653 CS Type B steel-, Shall conform with FBC Section 1503.2 Maximum dimensions of the vent are 24-inch wide x 102-inch long x 4.25-inch high. Vent is available in nominal 4-ft, 6-ft and 8-ft sizes. SEM14001.5a FL16994-R5 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Southeastern Metals Manufacturing Co., Inc. Off Ridge Vent TECHNICAL SERVICES, LLC PRODUCT APPLICATION Deck Type: Minimum 7/16-inch APA span rated OSB sheathing or 15/32-inch APA span rated plywood sheathing for new and existing roof deck (Deck shall be designed by others in accordance with FBC requirements). Roof slope.- Minimum 2:12 Installation Height: Maximum 33-ft Roof Cut -Out: 2.5-inch wide x 42-inch opening for the nominal 4-ft vent 2.5-inch wide x 66-inch opening for the nominal 6-ft vent 2.5-inch wide x 90-inch opening for the nominal 8-ft vent Attachment Method: Cut-out opening as prescribed above into the sheathing located a minimum 6-inch off the ridge. For a single vent, install the vent as close to the center of the roof length as possible. Multiple vents should be evenly spaced along the roof length. Remove interfering shingle nails around the perimeter of the opening and any debris prior to placing vent. Apply ASTM D 4586 or ASTM D 3409, Type I roofing cement/mastic to the underside of the perimeter flange to continuously surround and seal the flange. Position the vent over the opening in the roof sheathing. Slide the top and side flanges of the vent underneath the shingles and allow the bottom flange to lie on top of the shingles. Attach the vent with #9 x min. 1.5-inch HWH screws with 0.5- inch sealing washers or min. 12 ca. x 1-1/4-inch ring shank nails with min. 3/8-inch, diameter heads having sufficient length to penetrate through the sheathing a minimum of 3/8-inch. The fasteners shall be located 1-inch from the edge of the flange and 5.5- inches o.c. along all four sides of the vent. All loosened shingles shall be adhered down with roof cement/mastic. When nails are used to attach the vent, all penetrations through the vent flange shall be sealed using ASTM D 4586 or ASTM D 3409, Type I roofing cement/mastic. Allowable Roof Coverings: Asphalt shingles Maximum Design -13.5 psf for 4-ft and 6-ft vents Pressure -18 psf for 8-ft vent Pressures calculated using 2:1 margin of safety per 1504.9 SEM14001.5a FL16994-R5 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Southeastern Metals Manufacturing Co., Inc. ff Off Ridge VentC..'* R E E K TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is outside the scope of this evaluation. 2) This report is not for use in the HVHZ. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) SEMCO vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 6) Installation of the roof assembly is outside the scope of this evaluation. 7) SEMCO vents are intended to provide passive ventilation for an enclosed attic in residential construction applications 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by.the named manufacturer. 0111111111J.. Y R. No 74021 13' STATE OF 44J 0 R ONAC%N%%' CERTIFICATION OF INDEPENDENCE 2 017.10.10 10:29:43 04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R-. Priest, P.E. does not have, nor will --acquire, a financial interest in any other entity involved in the approval process of the product. I END OF REPORT SEM14001.5a FL16994-R5 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MIAMI-DADE COUNTY MIAMI- PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.niiarnidade.2ov/econ0n1V Southeastern Metals Manufacturing Company, Inc. 11801 Industry Drive Jacksonville, FL 32218 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Weather Vent LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miarni-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has. been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any sectionZD of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 08-042' ).01 consists of pages I through 3 The submitted documentation was reviewed by Juan E. Collao, R.A. NOA-No.: 13-0814.08 1 Expiration Date: 04/15/19 Approval Date: 01/23/14 Page I of 3 J ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Ventilation Material: Steel Minimum Slope: 2:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT: Manufactured by Dimensions Test Product Applicant Specifications Description Weather Vent Vent : 4- 1/2" x 19" x 46" TAS 100 Galvanized metal roof vent Deck Flange: 24" x 52" Thickness: 0.0217 inch. MANUFACTURING LOCATION 1. Jacksonville, FL EVIDENCE SUBMITTED Test A2ency Test Identifier Test Name/Report Date PRI Asphalt Technologies, Inc. TAS 100 SEM-002-02-01 08/14/03 ICC-ES AC132 SEM-027-02-01 01/07/14 APPROVED APPLICATIONS: Deck Type: Wood Deck Description: 15/ 32" or greater plywood or wood plank System Type A: Mechanical attachment of vent for shingle roofs Cutout: Mark a 3 )1/2" x 46" opening centered between layout lines and aligned minimum 6 inches from the ridge. Set blade to thickness of sheathing and cut opening. Brush away sawdust and debris. Installation: Vents should be evenly spaced on the rear slope of the roof. Center vent in opening and set it in a 1/8" thick of an approved ASTM D 4586 asphalt roofing cement. Secure vent to the roof deck with 1 -1/4" galvanized ring shank roofing nai-Is spaced approx. 8" o.c. and I" from the outside edge of the flange. Use a minimum of 18 nails per vent. Seal all nails and vent flange with an approved ASTM D 4586 roofing cement. (See drawings herein). Net Free Area: 99 square inches. NOA No.: 13-0814.08 Expiration Date: 04/15/19 Approval Date: 01/23/14 Page 2 of 3 LIMITATIONS: 1. Refer to applicable building code for required ventilation. Z: 2. Neather Vent shall comply with the manufacturer's current published application instructions and the requirements set forth in the applicable building code. Z: 3. This acceptance is for installations over asphaltic shingle roofs only. 4. Weather Vent shall not be installed on roof mean heights greater than 33 feet. Z 5. All products listed herein shall have a quality assurance audit in accordance with the Florida BuildingZD Code and Rule 9N-3 of the Florida Administrative Code. 6. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state, and following statement: "Miami -Dade County ProductC, Control Approved" or the Miami -Dade County Product Control Seal as shown below: FMMIARM IRDANDEEMCO U N TqY X DRAWINGS ROOF FLANGE NAIL PLACEMENT 0 0 0 0 a END OF THIS ACCEPTANCE NOA No.: 13-0814.08 Expiration Date: 04/15/19 Approval Date: 01/23/14 Page 3 of 3