Loading...
HomeMy WebLinkAbout505 Wylly Ave 17-2035; PORCH AWNING1 .rxn ;F July, � �. CITY OF SANFORD t: -Y'AT BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: r Q35 Documented Construction Value: $� Job Address: Historic District: Yes ElNo LJ Parcel Ill: \ Vesidential UCommercial ❑ Tyne of Work: New 11 Addition Alteration ❑ Repair ❑ Dento ❑ Cliaiige of Use ❑ Move ❑ Description of Work: c_ — rVA )Y (W Plan Review Contact Person: (��� �{ r�P.IL rA i Title: a( ��C1 Phone Fax• Email: i� Property Owner Information Name n'P Street: E3-6` omr. k1j Ile, ident of property?� City, State Zip: Contractor Information'h . . Name Phone: �':��cJx r.M"irfiw:;i4�ta l.:tx.niAs�,l,�wua�FF'ux,�"ti "ia{'r. Ana 4.Am,' Street: l+ax City, State Zip: �r. State} is Architect/Engineer Information Name: Phone: , Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Mort Leitcler: a ' Address:Address: -, WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENTMAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENT'S TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON TILE JOB SITE BEFORETHE FIRST INSPEC'T'ION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NO'T'ICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FSC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: Sth Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTES TO BUILDER/CONTRACTOR, 1, VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION, DIMENSIONS SHOWN ON THE PLANS ALWAYS TAKE PRECEDENCE OVER SCALE OF DRAWINGS. 2, VERIFY PLUMBING FIXTURE LOCATIONS AND INTERIOR BEARING FOOTINGS PRIOR TO FOUNDATION POUR, 3, THESE PLANS WERE ASSEMBLED WITH THE INTENT THAT ANY PERSON REASONABLY EXPERIENCED IN CONSTRUCTION WILL BE ABLE TO BUILD THE STRUCTURE SHOWN ON THESE PAGES, HOWEVER, THESE PLANS ARE NOT TO BE CONSIDERED A COMPLETE CONSTRUCTION INSTRUCTION MANUAL, NOR A COMPLETE TREATISE ON THE APPLICABLE CODES, 4, READ AND UNDERSTAND ALL DETAILS BEFORE COMMENCING CONSTRUCTION, MANY DETAILS REQUIRE A DEVIATION FROM STANDARD BUILDING PRACTICES SUCH AS REDUCED STUD SPACING, SPECIFIC LUMBER SPECIES, OR A PARTICULAR ORDER—OF—ASSEMBLY. THESE THINGS ARE MUCH EASIER TO CONSTRUCT CORRECTLY THE FIRST TIME THAN TO FIX AFTER THEY ARE ALREADY IN PLACE. 5, IF AT ANY TIME QUESTIONS ARISE ABOUT THE INTENT OF A NOTATION OR DETAIL, DO NOT PROCEED UNTIL YOU HAVE CONTACTED AND RECEIVED CLARIFICATION FROM SWEET. -- j KATHER11 /A Rwm"6kY boboom 9tA &*a% J'"% e pif Is Z5ANF�.jRmDmmhL FL 32773/MXVE, u ALTHOUGH GREAT CARE HAS BEEN TAKEN TO INSURE ACCURACY, MISTAKES CAN OCCUR, IT IS THE BUILDER'S RESPONSIBILITY T❑ VERIFY ALL DIMENSIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO SWEET BEFORE BEGINNING CONSTRUCTION, NOTE: IT IS THE RESPONSIBILITY OF THE BUILDING CONTRACTOR TO REVIEW TRUSS ENGINEERING PACKAGE AGAINST FLOOR PLAN AND ELEVATIONS i AND REPORT ANY DISCREPANCIES TO DESIGNER AND ENGINEER OF RECORD BEF❑RE CONSTRUCTION NOTE: CLIENT IS RESPONSIBLE FOR VERIFYING THAT PLANS ARE ACCEPTABLE BEFORE SIGN OFF SWEET IS NUT RESPONSIBLE FOR VERIFYING CONTRACTUAL DETAILS WITH CLIENT, NOTE: THIS PLAN SET HAS BEEN APPROVED FOR CONSTRUCTI❑N AS SITE SPECIFIC CONSTRUCTION OF MORE THAN ONE HOME OR VARIANCE FRUM PLAN SPECIFICATI❑NS IS PROHIBITED WITHOUT WRITTEN CONSENT OF ENGINEER OF RECORD, rrWWIsstia' r x l .: sss, rataas_aatszr me S R 'S"r"i- 6 ,,,,..• 26111 ft I OL T 9-fil SUr'rci"'fait:'{ (" n r..� i.47 i....i .. II" Af XF WIRE 5f 7-1-1-11 S �, I W+2,JA EYE28TH :�� -S1 V,, r��r�€.cr,«r Dr BLw 1 I T t w 2 trl: '7,l 29M 29i h' . {c Gf� ST 5E sl ME(Co f t (i'LTv., iw T YD /CiE"S@rI;OU ! irlttClA}� ..._.,.. �t3LzrY:u1 LN �- y ,..RirtUEtt # i3 x L !)WMA ST Ul, g ld�Wli�UR E, rT i !,045 ks-rt,:,� R arti tlVt7 i v� t---�_ r _==_a:=. -✓—_—'°tet., >arasaa�ru,t, � p1�% VICINITY MAP N.T.S. NO. INDEX DESCRIPTION LEGAL DESCRIPTION E 70 FT OF LOT 1 BLK 14 .A B RUSSELLS ADD FORT REED PB 1 PG 97 PARCEL I.D.#: 067.03150314000010 SCOPE OF WORK CONSTRUCT WOOD FRAMED ENTRY COVERING WITH ROOF. AREA TABULATION EXISTING STRUCTURE AREA 1,555 SQ. FT. FRONT PORCH AREA (PROPOSED) 46,1 SQ, FT. REAR PORCH AREA (PROPOSED) 46.1 SQ, FT, TOTAL PROP, AREA 1 CS COVER SHEET 2 Al EXIST. / PROSED SLAB PLAN 3 A2 PROPOSED ROOF PLAN 4 A3 EXISTING / PROPOSED ELEVATIONS (FRONT AND REAR) 5 A4 EXISTING .AND PROPOSED SIDE ELEVATIONS 6 S1 STRUCTURAL DETAIL SHEET 7 C1 PLOT PLAN (CIVIL) y263 AI Ifa1, Ok to construct front and rear porch as shown on plan. Meets area and dimension regulations for the SR -1 zoning district. SYMBOLS SECTION NUMBER PAGE NUMBER �— DIRECT OF SECTION RECOM) COPY f� t A Vlf vWED FOR CODE COMPLIANCE �i PLANS EXAM M ER DATE SAFORD BUILDING DIUI5it71�1 A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING CONSTRUCTION OR VIOLATIONS OF THIS CODE 1,647.2 SQ FT, BUILDING CODE CRITERIA: FLORIDA BUILDING CODES: NEW BUILDING CODE: FLORIDA BUILDING CODE -BUILDING 5TH EDITION (2014) FLORIDA BUILDING CODE -RESIDENTIAL 5T11 EDITION (2014) EXISTING BUILDING CODE: FLORIDA BUILDING CODE -EXISTING BUILDING 5TH EDITION (2014) ALTERATION LEVEL X CLASSIFICATION ELECTRICAL CODE: NATI9NAT,13LECT1dCAI. CODE 2011 PLUMBING CODE: FLORIDA BUILDING CODE PLUMBING 5TIIEDITION(2014) MECHANICAL CODE: FLORIDA BUILDING CODE -MECHANICAL 5TH F,I) rm (2014) GAS CODE: FLORIDA BUILDING CODE -FUEL GAS 5TH EDITION (2014) NFPA 58 LIQUIFIED PE'T'ROLEM GASSES LATEST EDITION NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS LA'TES'T OSHA ACCESSIBILITY 5TH EDITION (2014) FIRE CODES: FLORIDA FIRE PREVENTION CODE STH EDITION (2014) ENGINEERS NOTES ENGINE'ER'S REVIEW AND APPROVAL OF TRUSS INFORMATION AND LINTEL INFORMATION IS BASED UPON THE INFORMATION CONTAINED IIERIN, SHOULD TTIE OWNER OR CONTRACTOR CI IANGE TRUSS COMPANIES OR LINTEL COMPANFN FURTHER REVIEW 13Y THE BUILDING ENGINEER IS REQUIRED/ MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURE'S (ASCE/SEI 7 -IU) FLORIDA BUILDING CODEDESIGN WIND SPEED: STANDARD FOR RESIDENTIAL CONSTRUCTION IN I IIGI I WIND REGIONS ICC -680-08 V tilt = 140 mph, V asd = 108 mph figure 104 desigu wurd spccd (3 second gust): 110 mph WIND EXPOSURE CATEGORY= C RISK CATEGORY = II ENCLOSURE CLASSIFICATION=ENCLOSED LIVE LOADS: FLOOR LIVE LOAD = 40 psX ROOF LIVE LOAD = 16 PSF OTHER DEAD LOADS = ACTUAL WEIGHT OF MATERIALS BUILDING = UNPROTECTED AND UNSI'RINKLFD C:) OO 'I- raj N Qo II O Ln N Q I I Lo �7 EX S REAR (SOUTH)T N G 4" SLAB WITH 12" FOOTER 35)_0„ @ CORNERS TYR I f EXIST. 19'-9 SLAB ----- 7'-5 1 '51 /2 '41 2 3)_0-2'—O 1 „ 5'— 1 o" 3'136DH R'JI 3068 cl 4" 313ODH ,\ yV`. ` _\V vy�\" v v ,. A A \'`v V ,. `v ., V '`,. A,. \',A `'` `' A`• A `� \ \, v A,, v `, A, v v V v• `V ` .,... �r g ` LIVING ,.�.` gq � EX q y^$��.,.p.-..�..:.� 3�pg::rr....,:.,.....:.:..,..:.......,::s.. i 1 L �i i i �y 9 fi1V1. sR iii T. BE �`�eM. 3136DH 3136DH ° 8 I 3132DFI 3132DH : 3'-6 1/20'3, 1,1 31„ 3'--/...1/2„ 3> 11> 3,-11, 3,-7, _,_,_-._......._...__ -I -4" ,i 5' 7" i a v 'd a' FRONT (NORTHY., , v „a EXISTING 4" SLAB WITH 12" FOOTER . a @ CORNERS TYP. co T Q v co O !.n N 4a EXISTING 4" CONC, S/W v 4 EXISTING :SLAB PLAN (" AS - BUILT") 1/411 = 11-011 REAR (SOUTH) 35'-0" PROPOSED SLAB ALAN BUILDING CODE CRITERIA: FLORIDA BUILDING CODES: NEW BUILDING CODE: FLORIDA BUILDING CODE -BUILDING 5TH EDITION (2014) FLORIDA BUILDING CODE -RESIDENTIAL 5TH EDITION (2014) EXISTING BUILDING CODE: FLORIDA BUILDING CODE -EXISTING BUILDING 5TH EDITION (2014) ALTERATION LEVEL X CLASSIFICATION ELECTRICAL CODE: NATIONAL ELECTRICAL CODE 2011 PLUMBING CODE: FLORIDA BUILDING CODE -PLUMBING STH EDITION (2014) MECHANICAL CODE: FLORIDA BUILDING CODE -MECHANICAL 5TH EDITION (2014) GAS CODE: FLORIDA BUILDING CODE -FUEL GAS 51H EDITION (2014) NFPA 58 LIQUIFIED PEl'ROLEM GASSES LATEST EDITION NFYA 13 INSTALLATION OF SPRINKLER SYSTEMS LATEST Q511A ACCESSIBILITY 5TH EDITION (2014) FIRE CODES: FLORIDA FIRE PREVEN'T'ION CODE 5TH EDITION (2014) ENGINEERS NOTES ENGINEER'S REVIEW AND APPROVAL OF TRUSS INFORMATION AND LINTEL INFORM :ITON IS BASED UPON THE INFORMATION CONTAINED 11ERlN, SIIUULD THE OWNER OR CONTRACTOR CHANGE TRIJSS COMPANIES OR LIN"TEL COMPANIES, FUWI71ER REVIEW B Y THE BUILDING ENGINEER IS REQUIRED/ MINIMUM DES (GN LOAD S FOR BUILAINGS AND OTHER STRUCTURES (ASCE/SEI 7-1o) FLORIDA BUILDING CODE DESIGN WIND SPEED: STANDARD FOR RESIDENTIAL CONSTRUCTION IN HIGH WIND REGIONS ICC -600-08 V ult = 14U mph, V asd =108 Inph figure 104 design wind speed (3 second gusl): 110 mph WIND EXPOSURE CATEGORY = C RISK CATEGORY = It ENCLOSURE CLASSIFICATION =ENCLOSED LIVE LOADS: FLOOR LIVE LOAD = 40 psf ROOF LIVE LOAD = 16 PSF OTHER DEAD LOADS = ACTUAL WEIGHT OF MATERIALS BUILDING = UNPROTECTED AND UNSPRINKLED 4" 313ODH ,\ yV`. ` _\V vy�\" v v ,. A A \'`v V ,. `v ., V '`,. A,. \',A `'` `' A`• A `� \ \, v A,, v `, A, v v V v• `V ` .,... �r g ` LIVING ,.�.` gq � EX q y^$��.,.p.-..�..:.� 3�pg::rr....,:.,.....:.:..,..:.......,::s.. i 1 L �i i i �y 9 fi1V1. sR iii T. BE �`�eM. 3136DH 3136DH ° 8 I 3132DFI 3132DH : 3'-6 1/20'3, 1,1 31„ 3'--/...1/2„ 3> 11> 3,-11, 3,-7, _,_,_-._......._...__ -I -4" ,i 5' 7" i a v 'd a' FRONT (NORTHY., , v „a EXISTING 4" SLAB WITH 12" FOOTER . a @ CORNERS TYP. co T Q v co O !.n N 4a EXISTING 4" CONC, S/W v 4 EXISTING :SLAB PLAN (" AS - BUILT") 1/411 = 11-011 REAR (SOUTH) 35'-0" PROPOSED SLAB ALAN BUILDING CODE CRITERIA: FLORIDA BUILDING CODES: NEW BUILDING CODE: FLORIDA BUILDING CODE -BUILDING 5TH EDITION (2014) FLORIDA BUILDING CODE -RESIDENTIAL 5TH EDITION (2014) EXISTING BUILDING CODE: FLORIDA BUILDING CODE -EXISTING BUILDING 5TH EDITION (2014) ALTERATION LEVEL X CLASSIFICATION ELECTRICAL CODE: NATIONAL ELECTRICAL CODE 2011 PLUMBING CODE: FLORIDA BUILDING CODE -PLUMBING STH EDITION (2014) MECHANICAL CODE: FLORIDA BUILDING CODE -MECHANICAL 5TH EDITION (2014) GAS CODE: FLORIDA BUILDING CODE -FUEL GAS 51H EDITION (2014) NFPA 58 LIQUIFIED PEl'ROLEM GASSES LATEST EDITION NFYA 13 INSTALLATION OF SPRINKLER SYSTEMS LATEST Q511A ACCESSIBILITY 5TH EDITION (2014) FIRE CODES: FLORIDA FIRE PREVEN'T'ION CODE 5TH EDITION (2014) ENGINEERS NOTES ENGINEER'S REVIEW AND APPROVAL OF TRUSS INFORMATION AND LINTEL INFORM :ITON IS BASED UPON THE INFORMATION CONTAINED 11ERlN, SIIUULD THE OWNER OR CONTRACTOR CHANGE TRIJSS COMPANIES OR LIN"TEL COMPANIES, FUWI71ER REVIEW B Y THE BUILDING ENGINEER IS REQUIRED/ MINIMUM DES (GN LOAD S FOR BUILAINGS AND OTHER STRUCTURES (ASCE/SEI 7-1o) FLORIDA BUILDING CODE DESIGN WIND SPEED: STANDARD FOR RESIDENTIAL CONSTRUCTION IN HIGH WIND REGIONS ICC -600-08 V ult = 14U mph, V asd =108 Inph figure 104 design wind speed (3 second gusl): 110 mph WIND EXPOSURE CATEGORY = C RISK CATEGORY = It ENCLOSURE CLASSIFICATION =ENCLOSED LIVE LOADS: FLOOR LIVE LOAD = 40 psf ROOF LIVE LOAD = 16 PSF OTHER DEAD LOADS = ACTUAL WEIGHT OF MATERIALS BUILDING = UNPROTECTED AND UNSPRINKLED I ELECTRICAL LEG EN D SYMBOL DESCRIPTION =0 DUPLEX RECEPTACLE =M1/2 S.W. SWITCHED DUPLEX RECEPTACLE �GFl GFI PROTECTED RECEPTALCE =GwP/cn WEATHERPROOF/GFI PROTECTED RECEPTACLE �s SINGLE RECEPTACLE 49� 220 VOLT OUTLET =@cLc. DUPLEX RECEPTACLE (CEILING MOUNTED) $ SINGLE POLE SINGE THROW SWITCH a 3—WAY SWITCH 4—WAY SWITCH CEILING MOUNTED INCANDESCENT- FIXTURE H SUSPENDED INCANDESCENT FIXTURE �R RECESSED INCANDESCENT FIXTURE wT RECESSED WATERTIGH'r INCANDESCENT FIXTURE OE RECESSED EYEBALL INCANDESCENT FIXTURE 01 FLOURESCENT LIGHTING FIXTURE 1--0 WALL MOUNTED FIXTURE v FLOOD LIGHT 0 -TELEPHONE 6 DOOR CHIMES ❑ PUSH BUTTON FOR DOOR CHIME CABLE TELEVISION OUTLET CEILING FAN LOCATION OR PREWIRE sD SMOKE DETECTOR —OI THERMOSTAT Cp CARBON MONOXIDE DETECTOR 1/411 = 114" NO. REVISION AND DATE ITEM ) 2x6 ROOF RAFTERS 24"O. C. TYP. FRONT AND REAR LIMITS OF CONSTRUCTION CHAD LINN P.E. LIC. # 57524 P.O. BOX 140024, ORLANDO fL. 32714 PHONE: 407-525-6433 NOTE: FOOTERS HAVE BEEN EXCAVATED TO DETERMINE S ZE,AND CONT. STEEL REBARS (2) VER E EDTO BE ADEQUATE FOR 1 STY CONSTRUCTION, AS PER CERTIFICATION BY STRUCTURAL ENGINEER OF RECORD, IF ANY FOOTERS ARE DISCOVERED UNDERSIZED, APPROPATE DRAWINGS WILL BE GENERATED TO CORRECT LOOTER SIZE, NO CONCRETE WORK SHALL BE PERFORMED UNTIL LINTELS HAVE BEEN INSPECTED,AND APPROVED FOR POUR BY SEMINOLE COUNTY BUILDING DEPT LEGEND �—f EXISTING CONCRETE (8" BLK) LOAD BEARING WALL PROPOSED CONCRETE (8" BLK) LOAD BEARING WALL %Yc PROPOSED WOOD LOAD BEARING WALL (STUDS 16" O.C,) _ :.. PROPOSED 6" WOOD FRAME WALL PROPOSED 4" WOOD FRAME WALL INFILL WITH STUDS OR CMU HB= HOSE BIB M,T.= METAL THRESHOLD BUILDING CODE CRITERIA.: FLORIDA BUILDING CODES: NEW BUILDING CODE: FLORIDA BUILDING CODE -BUILDING 5TH EDITION (2014) FLORIDA BUILDING CODE -RESIDENTIAL 5TH EDITION (2014) EXISTING BUILDING CODE: FLORIDA BUILDING CODE -EXISTING BUILDING 5TH EDITION (2014) ALTERATION LEVEL X CLASSIFICATION ELECTRICAL CODE: NATIONAL ELECTRICAL CODE 2011 PLUMBING CODE: FLORIDA BUILDING CODE -PLUMBING 5TH EDITION (2014) MECHANICAL CODE: FLORIDA BUILDING CODE -MECHANICAL 5TH EDITION (2014) GAS CODE: FLORIDA BUILDING CODE -FUEL GAS 5TH EDITION (2014) NFPA 58 LIQUIFIED PETROLEM GASSES LXFEST EDITION NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS LATEST OSHA ACCESSIBILITY 5TH EDITION (2014) FIRE CODES: FLORIDA FIRE PREVENTION CODE 5TH EDITION (2014) CNGINEERS NOTES ENGINEER'S REVIEW AND APPROVAL OF TRUSS INFORMA'T'ION AND LINTEL INFORMATION IS BASED UPON THE INFORMATION CONTAINED HERIN, SHOULD THE OWNER OR CONTRACTOR CHANGE TRUSS COMPANIES OR LINTEL COMPANIFS, FURTHER REV EW BY THE BUILDING ENGINEER IS REQUIRED/ MINIMUM DESIGN LOADS FOR BUILDINGS AND OTflER STRUCTURES (ASCE/SE17-10) FLORIDA BUILDING CODE DESIGN WIND SPEED: STANDARD FOR RESIDENTIAL CONSTRUCTION IN HIGH WIND REGIONS ICC -600-08 V tilt = 140 mph, V;W = 108 mph figwe 104 design wind speed (3 second gitst): 110 mph WIND EXPOSURE CATEGORY = C RISK CATEGORY = It ENCLOSURE CLASSIFICATION = ENCLOSED LIVE LOADS: FLOOR LIVE LOAD = 40 psf ROOF LIVE LOAD = 16 PSF OTHER DEAD LOADS = ACTUAL WEIGHT OF MATERIALS BUILDING = UNPROTECTED AND UNSPRINKLED SWEET "We Brines Vision To LliW l Phone: (3002$0=5507 Email: 1lifefricnd gmail.com PLAN FOR:HARDY KATHERINE L ADDRESS: 505 WYLLY AVE, SANFORD FL 32773 DATE: 06/2017 SCALE: PAGE: IARC E L#: 06203150314000010vA­2 FXISTING FRONT F[ -F V ATIO1 M �[ Q EXISTING VG REAR ELEVATION \,AT101 M 1 /4n = 1'—On PROPOSED 4X6 BEAM (EACH SIDE) NOTE: DRAWINGS REELECT "AS BU LT" FIELD CON D T ON S� PROPOSED 4:12 FOOE P TCH (T-�c�nr-�n�-,��- PROPOSED T1-1 1 WOOD D N G MATCH PROPOSED FRONS ELEVATION 1/411 11-01? PROPOSED REAR ELEVATION FCH EX ST N G) PITCH (-I-yp.) BEAM (EACH DE) BUILDING CODE CRITERIA: FLORIDA BUILDING CODES: NEW BUILDING CODE: FLORIDA BUILDING CODE -BUILDING 5TH EDITION (2014) FLORIDA BUILDING CODE -RESIDENTIAL 5TH EDITION (2014) EXISTING BUILDING CODE: FLORIDA BUILDING CODE -EXISTING BUILDING 5TH EDITION (2014) AL'TERA'TION LEVEL X CLASSIFICATION ELECTRICAL CODE: NATIONAL ELECTRICAL CODE 2011 PLUMBING CODE: FLORIDA BUILDING CODE -PLUMBING 5TH EDITION (2014) MECHANICAL CODE: FLORIDA BUILDING CODE -MECHANICAL 5TH EDITION (2014) GAS CODE: FLORIDA BUILDING CODE -FUEL GAS 5TR EDITION (2014) NFPA 58 LIQUIFIED PETROLEM GASSES LATEST EDITION NFPA U INSTALLATION OF SPRINKLER SYSTEMS LATESTOSIIA ACCESSIBILITY 5TH EDITION (2014) FIRE CODE,;: FLORIDA FIRE PREVENTION CODE 5TH EDITION (2014) ENGINEERS NorrES ENGINEER'S REVIEW AND APPROVAL OF TRUSS INFORMATION AND LINTEL iNFOI2NIATION 1S BASED UPON THE INFORMATION CONTAINED IIER[N, SHOULD 1111 OWNER OR CONTRACTOR CHANGE 'TRUSS COMPANIES OR LINTEL COMPANIES, FURTHER REVIEW BY THE BUILDING ENGINEER 1S REQUIRED/ MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE/SE17-10) FLORIDA BUILDING CODE DESIGN WIND SPEED: STANDARD FOR RESIDENTIAL CONSTRUCTION IN HIGH WIND REGIONS ICC -G00-08 V ult = 140 mpk V aed = 108 mph figure 104 design wind speed (3 second gust): 110 mpli WIND EXPOSURE CATEGORY = C RISK CATEGORY = U ENCLOSURE CLASSIFICATION = ENCLOSED LIVE LOADS: FLOOR LIVE LOAD = 40 psf ROOF LIVE LOAD = 16 PSF OTHER DEAD LOADS = ACTUAL WEIGHTOF MATERIALS BUILDING = UNPROTECTED AND UNSPRINKLED EXISTING 4"THICK SLAB (TO REMAIN) PROPOSED 4X6 P, T. POST (EACH SIDE) F o p p � EXIST1\10- 4"T- CK SLAB (TO REMAIN) C�l EXISTING SIDE ELEVATION (EAST) 1/411 = V-011 EXISTING SIDE ELEVATION (WEST) PROPOSED SIDE ELEVATION (WEST) PROPOSED FLOOR PLAN 1/ 1) = it -Ott NO. REVISION AND DATE ITEM A Simpson Strong—Tie I -I U S26 (SEE DETAIL SHT, SI FOR DETAILS) PROPOSED 4-X6 BEAM (EACH SIDE) //--PROPOSED SIMPSON ABU66 TYP, (4) PLCS, SWEET "We Bring Visions To Life" Phone: (305)280-5507 Email: llifefriend@gmail.com PLAN FOR: HARDY KATHERINE L 505 WYLLY AVE, ADDRESS: SANFORD FL 32773 CHAD LINN P.E. LIC. # 57524 DATE: 06/2017 SCALE: PAGE: P.O. BOX 140024, ORLANDO fL. 32714 PHONE, 407-525-6433 jD IARC E111: 06203150314000010 A-4 BUILDING CODE CRITERIA: FLORIDA BUILDING CODES: NEW BUILDING CODE: FLORIDA BUILDING CODE -BUILDING 5TH EDITION (2014) FLORIDA BUILDING CODF-RFSIDF.NTIAL 5TH EDITION (2014) EXISTING BUILDING CODE: FLORIDA BUILDING CODE -EXISTING BUILDING 5TH EDITION (2014) ALTERATION LE: VEL X CLASSIFICATION L'LECT'RiCAL CODE: NATIONAL ELECTRICAL CODE 2011 PLUMBING CODE: FLORIDA BUILDING CODE -PLUMBING 511I EDITION (2014) MECHANICAL CODE: FLORIDA BUILDING CODE-Iyl1,'CHANICAL 5TH EDITION (2014) GAS CODE: FLORIDA BUILDING CODE -FUEL GAS 5TH L'DTTION (20 14) NFFA 58 LIQUIFIED PETROLEM GASSES LATEST EDI'T'ION NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS LATEST OSITA ACCESSIBILITY 5TH EDITION (2014) FIRE CODES: FLORIDA FIRE PREVENTION CODE STH EDITION (2014) ENGINEERS NOTES ENGINEER'S REVIEW AND APPROVAL OF TRUSS INFORMATION AND LINTEL INFORMATION IS BASED UPON THE INFORMATION CONTAINED HERIN, SHOULD TME OWNER OR CONTRACTOR CHANGE TRUSS COMPANIES OR LINTEL COMPANIES, FURTHER REVIEW BY THE BUILDING ENGINEER IS REQUIRED/ MINRvIUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURE'S (ASCE/SEI7-10) FLORIDA BUILDING CODE DESIGN WIND SPEED: STANDARD FOR RESIDENTIAL CONSTRUCTION IN HIGII WIND REGIONS ICC -600 08 V Tilt = 140 mph, V asd = 108 mph figure 104 design wind speed (3 wevad gwL t): 110 mph WIND EXPOSURE CATEGORY = C RISK CATEGORY = II ENCLOSURE CLASS1 ICA'1'ION = ENCLOSED LIVE LOADS: FLOOR LIVE LOAD = 40 p;l ROOF LIVE LOAD = 16 PSF OTHER DEAD LOADS = ACTUAL WEIGHT OF MATERIALS BUILDING = UNPROTECTED AND UNSPRINKI,ED PROPOSED 2X6 RAFTEI SIMPC @ EA 1x FASCIA W/ GAL DR ).P CONT 1E PROPOSED FRAMING DETAIL GENERAL. N N__`E 1, CONTRACTOR IS TO ASCERTAIN THAT ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL APPLICABLE BUILDING 'CODES AND LOCAL RESTRICTIONS AND THAT THE CONSTRUCTION DOCUMENTS ARE IN ACCW,, DANCE WITH APPLICABLE LAWS, STATUS, ORDINANCES, CODES, RULES, AND REGU'L;ATIONS. IF THE CONTRACTOR OBSERVES T�iAT PORTIONS OF THE CONSTRUCTION DOCUYNETS ARE AT VARIANCE THEREWITH, THEA CONTRACTOR SHALL PROPMPTLY NOTIFY'; °THE DESIGNER IN WRITING AND THE NECESARY CHANGES SHALL BE INITIATED AND ACCOMPLISHED BY APPROPRIATE MODIFICATION, 2. DIMESIONS TAKE PRECEDEN1c.E OVER DRAWINGS, DO NOT SCALE DRAWINGS ;TO DETERMINE ANY LOCATIONS, IF ANY DISCREPANCIES OCCUR, NOTIFY THE DESIGNER AT `:ONCE FOR CLARIFICATION, 3, ALL WOOD IN CONTACT WITH MASONRY, CONCRETE OR STEEL SHALL BE PRESSURE TREATED. I 4. ALL PRODUCTS AMD MATERIALS SHALL BE APPLIED AND/OR INSTALLED IN AC'QORDANCE WITH THE MANUFACTURER'S PUBLISHE=D SPECIFICATIONS. 5. CONTRACTOR SHALL VERIFY ALL WINDOW AND DOOR MASONRY OPENINGS WITH MANUFACTURER PRIOR TO COMMENCEMENT OF CONSTRUCTION, 6, ALL PLAN DIMENSIONS ARE. FROM FACE OF BLOCK OR FACE STUD AND ARE NOMINAL UNLESS OTHERWISE INDICATED. 8. THIS STRUCTURE HAS BEEA DESIGNED TO MEET OR EXCEED THE 120 MPH WIND LOAD REQUIREMENTS OF THE FLORIDA RESIDENTIAL BUILDING CODE, 2014, 5TH EDITION 9, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WATER PROOFING. 10. ALL LUMBER SHALL BE S`I'P ##2 OR BETTER N,T,S, GENERAL NOTES RIDGE CONT XIS"rINC WOOD 1) CODES: 1.1 FLORIDA RESIDENTIAL BUILDING CODE (2014). 5TH ED. 1.2 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-95). 1.3 AMERICAN SOCIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7-95). 2) CONCRETE: 2.1 CONCRETE COMPRESSIVE STRENGTH AT 28. DAYS: 2.1.1 PRE -CAST W/STANDARD REINFORCEMENT - 3500 PSI 2.1.2. PRE -CAST W/PRESTRESS REINFORCEMENT - 5000 PSI 2.1.3. CONCRETE FILL (PLACED IN FIELD) - 2500 PSI 2.2 REINFORCING BARS: 2.2.1. STEEL PLACED IN PRECAST LINTEL AT TIME OF FABRICATION ASTM A615 (GRADE 60). 22.2. STEEL IN LINTEL AND KNOCKOUT BLOCK (PLACED IN FIELD) ASTM A615 (GRADE 40). 2.3 PRESTRESS STRANDS ASTM A416 7 -WIRE 2.4 DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 315. 2.5 CONCRETING OPERATIONS SHALL COMPLY WITH ACI STANDARDS. 3) MASONRY: 3,1 DESIGN AND CONSTRUCTION SHALL CONFORM TO THE SPECIFICATION OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND ACI 530. 3.2 MINIMUM MASONRY UNIT STRENGTH: fm 1250 PSI. 3.3 MORTAR SHALL BE TYPE S OR M. 4) STRUCTURAL: 4.1 SAFE LOAD VALUES AiRI✓ BASED ON LINTEELS HAVING A BEARING OF 8" (WITH A MINIMUM ACOMYI"ABLE BEARING OF 4" PER SECTION 2101.3.1 OF THE 2014 RESIDENTIAL EDITION OF THE FLORIDA BUILDING CODE) , 5TH ED. ROOF & END GABLE: 8d RING SHANK NAILS AT 4" O.C. AT SUPPORTED PANEL EDGES OF 7/16" MIN. APA RATED OSB PLYWOOD , W/8d NAILS AT 6" O.C. AT INTERIOR SUPPORTS. WALL SHEATHING: 8d NAILS AT 6" O.G. AT SUPPORTED PANEL EDGES OF 1/2" APA RATED OSB PLYWOOD , W/8d NAILS AT 12" O.C. AT INTERIOR SUPPORTS, Sirnps, M TS12 I-I\UI- U.JLV DBL. 2X6 HEADER (P.T.) fl sort Strong -Tie PROPOSED FRAMING DETAIL '"'IMON) OR .14 3X3 1/4" (160 SINKER) NAIL DBL. 2x6 P.T. (TYP,) SIMPSON U US 16 DETAIL (HSUR26-2) N.T.S. V V I V Y L I Y I I V I V f l L I I\ f l I V 111 V V J I /l I V J MAX SPAN 24"O.C. CONNECTOR SCHEDULE CEILING JOISTS MODEL # FASTENERS UPLIFT(133) CAPACITY SP -1 6-10d 4-10d 585 SP -2 6-1Od 6-10d 890 SP -4 6- l Odx 1 735 MTS12 14- l Odx1 1000 MTS20 14-10dx1 1000 LSTA12 10-10d 755 LSTA24 18-10d 1295 1 STA30 22-10d 167D LSIA36 26-10d 1715 CEILING -/11. _ 1 Od 1715 'TA 202 24"o.c. 21'4" max span 1995 I FTA16 _ 1I-1Odx1\_(1 Pl r r<) 1365 HFTAlfl 11-1r"] (2-p1Y-fr1jq5) 2x4 AS REQU BY TRUSS - \ I H90 DESIGN & AS REQ'D IN HI IS26 14 5-16d 1550 UC - - 111122 32-ILia sinker±id bolt 5260 ARIJ44 12-16d±id bolt 2200 ARLJ66 12-16cl-Od bolt ?300 A I 18 -166+2 -id bo HIO H-Bdxl\ 8-8dx1 90,11 H3 4-8d 4-8d 455 A x1 MQT22-10d 3655 Q - 14-16d sinkers1785 C - 2 6-]Qd+rdI5465 HGT-3 8-10d+ d bolt 9035 MBHA 18-10d + 1 ATR X8 face&to 3145 M HA H=7 1 -1 + 1 A:TR[xb T P 1885 & 1 ATR X4 FACE META 18 H=14 9-10d X 1-1 2 1450 ATR is all threaded rod BUILDING CODE CRITERIA: FLORIDA BUILDING CODES: NEW BUILDING CODE: FLORIDA BUILDING CODE -BUILDING 5TH EDITION (2014) FLORIDA BUILDING CODF-RFSIDF.NTIAL 5TH EDITION (2014) EXISTING BUILDING CODE: FLORIDA BUILDING CODE -EXISTING BUILDING 5TH EDITION (2014) ALTERATION LE: VEL X CLASSIFICATION L'LECT'RiCAL CODE: NATIONAL ELECTRICAL CODE 2011 PLUMBING CODE: FLORIDA BUILDING CODE -PLUMBING 511I EDITION (2014) MECHANICAL CODE: FLORIDA BUILDING CODE-Iyl1,'CHANICAL 5TH EDITION (2014) GAS CODE: FLORIDA BUILDING CODE -FUEL GAS 5TH L'DTTION (20 14) NFFA 58 LIQUIFIED PETROLEM GASSES LATEST EDI'T'ION NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS LATEST OSITA ACCESSIBILITY 5TH EDITION (2014) FIRE CODES: FLORIDA FIRE PREVENTION CODE STH EDITION (2014) ENGINEERS NOTES ENGINEER'S REVIEW AND APPROVAL OF TRUSS INFORMATION AND LINTEL INFORMATION IS BASED UPON THE INFORMATION CONTAINED HERIN, SHOULD TME OWNER OR CONTRACTOR CHANGE TRUSS COMPANIES OR LINTEL COMPANIES, FURTHER REVIEW BY THE BUILDING ENGINEER IS REQUIRED/ MINRvIUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURE'S (ASCE/SEI7-10) FLORIDA BUILDING CODE DESIGN WIND SPEED: STANDARD FOR RESIDENTIAL CONSTRUCTION IN HIGII WIND REGIONS ICC -600 08 V Tilt = 140 mph, V asd = 108 mph figure 104 design wind speed (3 wevad gwL t): 110 mph WIND EXPOSURE CATEGORY = C RISK CATEGORY = II ENCLOSURE CLASS1 ICA'1'ION = ENCLOSED LIVE LOADS: FLOOR LIVE LOAD = 40 p;l ROOF LIVE LOAD = 16 PSF OTHER DEAD LOADS = ACTUAL WEIGHT OF MATERIALS BUILDING = UNPROTECTED AND UNSPRINKI,ED PROPOSED 2X6 RAFTEI SIMPC @ EA 1x FASCIA W/ GAL DR ).P CONT 1E PROPOSED FRAMING DETAIL GENERAL. N N__`E 1, CONTRACTOR IS TO ASCERTAIN THAT ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL APPLICABLE BUILDING 'CODES AND LOCAL RESTRICTIONS AND THAT THE CONSTRUCTION DOCUMENTS ARE IN ACCW,, DANCE WITH APPLICABLE LAWS, STATUS, ORDINANCES, CODES, RULES, AND REGU'L;ATIONS. IF THE CONTRACTOR OBSERVES T�iAT PORTIONS OF THE CONSTRUCTION DOCUYNETS ARE AT VARIANCE THEREWITH, THEA CONTRACTOR SHALL PROPMPTLY NOTIFY'; °THE DESIGNER IN WRITING AND THE NECESARY CHANGES SHALL BE INITIATED AND ACCOMPLISHED BY APPROPRIATE MODIFICATION, 2. DIMESIONS TAKE PRECEDEN1c.E OVER DRAWINGS, DO NOT SCALE DRAWINGS ;TO DETERMINE ANY LOCATIONS, IF ANY DISCREPANCIES OCCUR, NOTIFY THE DESIGNER AT `:ONCE FOR CLARIFICATION, 3, ALL WOOD IN CONTACT WITH MASONRY, CONCRETE OR STEEL SHALL BE PRESSURE TREATED. I 4. ALL PRODUCTS AMD MATERIALS SHALL BE APPLIED AND/OR INSTALLED IN AC'QORDANCE WITH THE MANUFACTURER'S PUBLISHE=D SPECIFICATIONS. 5. CONTRACTOR SHALL VERIFY ALL WINDOW AND DOOR MASONRY OPENINGS WITH MANUFACTURER PRIOR TO COMMENCEMENT OF CONSTRUCTION, 6, ALL PLAN DIMENSIONS ARE. FROM FACE OF BLOCK OR FACE STUD AND ARE NOMINAL UNLESS OTHERWISE INDICATED. 8. THIS STRUCTURE HAS BEEA DESIGNED TO MEET OR EXCEED THE 120 MPH WIND LOAD REQUIREMENTS OF THE FLORIDA RESIDENTIAL BUILDING CODE, 2014, 5TH EDITION 9, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WATER PROOFING. 10. ALL LUMBER SHALL BE S`I'P ##2 OR BETTER N,T,S, GENERAL NOTES RIDGE CONT XIS"rINC WOOD 1) CODES: 1.1 FLORIDA RESIDENTIAL BUILDING CODE (2014). 5TH ED. 1.2 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-95). 1.3 AMERICAN SOCIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7-95). 2) CONCRETE: 2.1 CONCRETE COMPRESSIVE STRENGTH AT 28. DAYS: 2.1.1 PRE -CAST W/STANDARD REINFORCEMENT - 3500 PSI 2.1.2. PRE -CAST W/PRESTRESS REINFORCEMENT - 5000 PSI 2.1.3. CONCRETE FILL (PLACED IN FIELD) - 2500 PSI 2.2 REINFORCING BARS: 2.2.1. STEEL PLACED IN PRECAST LINTEL AT TIME OF FABRICATION ASTM A615 (GRADE 60). 22.2. STEEL IN LINTEL AND KNOCKOUT BLOCK (PLACED IN FIELD) ASTM A615 (GRADE 40). 2.3 PRESTRESS STRANDS ASTM A416 7 -WIRE 2.4 DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 315. 2.5 CONCRETING OPERATIONS SHALL COMPLY WITH ACI STANDARDS. 3) MASONRY: 3,1 DESIGN AND CONSTRUCTION SHALL CONFORM TO THE SPECIFICATION OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND ACI 530. 3.2 MINIMUM MASONRY UNIT STRENGTH: fm 1250 PSI. 3.3 MORTAR SHALL BE TYPE S OR M. 4) STRUCTURAL: 4.1 SAFE LOAD VALUES AiRI✓ BASED ON LINTEELS HAVING A BEARING OF 8" (WITH A MINIMUM ACOMYI"ABLE BEARING OF 4" PER SECTION 2101.3.1 OF THE 2014 RESIDENTIAL EDITION OF THE FLORIDA BUILDING CODE) , 5TH ED. ROOF & END GABLE: 8d RING SHANK NAILS AT 4" O.C. AT SUPPORTED PANEL EDGES OF 7/16" MIN. APA RATED OSB PLYWOOD , W/8d NAILS AT 6" O.C. AT INTERIOR SUPPORTS. WALL SHEATHING: 8d NAILS AT 6" O.G. AT SUPPORTED PANEL EDGES OF 1/2" APA RATED OSB PLYWOOD , W/8d NAILS AT 12" O.C. AT INTERIOR SUPPORTS, Sirnps, M TS12 I-I\UI- U.JLV DBL. 2X6 HEADER (P.T.) fl sort Strong -Tie PROPOSED FRAMING DETAIL '"'IMON) OR .14 3X3 1/4" (160 SINKER) NAIL DBL. 2x6 P.T. (TYP,) SIMPSON U US 16 DETAIL (HSUR26-2) N.T.S. V V I V Y L I Y I I V I V f l L I I\ f l I V 111 V V J I /l I V J MAX SPAN 24"O.C. RAFTER SPANS CEILING JOISTS FLOOR JOISTS 2x6 12"v,c, 14'9" max span 2x4 12"o.c. 9'3" max span 2x12 12"o,c, 23'4" rrlax span 2x6 16"o,c. 13'5° rnax span 2x4 16"o,c. 8'-/" max span 2x12 16"o.c, 20'2" rnax span 2x6 24"o.c. 11'9" max span 2x4 24"o.c. 7'3" max span 2x12 24"o.c. 16'6" rnax span 2x8 12"o.c, 19'6" max span 2x6 12"o.c. 14'9" max span 2x10 12"o.c. 19'11" max span 2x6 16"v.c, 17'9° max span 2x6 16"a.c. 12'11" max span 2x10 16"o,c, 17'3" max span 2x8 24"o.c. 13'2" max span 2x6 24"o.c. 10'6" rnax span 2x10 24"o.c. 14'1" max span 2x10 12"o.c, 24'10° max span 2x8 12"a.c. 19'2" max span 2x10 16"o.c. 22'1" max span 2x8 16"ac. lEi"%" max span '2X4 DIACONAL BRACE (08) 2x10 24"o.c. 18'1" max ;pan 2x824"o.c. 13'7" rnax span AT EA, ENO WALL 2x1'2 12"o,c, 26'0" max Span 2x10 12"o.c. 22'9" max Spon CEILING -/11. 2x12 16"o, a, 26'0" max span 2x10 16"o.c. 19'9" max span 202 24"o.c. 21'4" max span 2x10 24"o.c. 16'1" max upon NOTE: ALL SPANS BASED ON #2 SOUTHERN YELLOW PINE DESIGN LOADS OF 20 PSF-LIVE LOADS NOTES: 1. FOUNDATION DESIGN BASED ON 2000 P.S.F. MINIMUM ALLOWABLE BEARING PRESSURE, SUBMIT SOILS REPORT BY FLORIDA REGISTERED ENGINEERING FOR REVIEW PRIOR TO FOUNDATION POUR, 2, ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH A.C.I. 301-79 AND SHOP DRAWINGS WITH A.C.I, 3-15-80. SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONC. POUR, 3. CONCRETE 28 DAY STRENGTH; SLABS, FOOTING; 2500 P.S.I. 2/ 3/4" MAX. AGGT:EGA'rE. 4. REINFORCING S'rEEL; ASTM A615, GRADE 60 EXCEPT STIRRUPS AND TIES MAY BE GRADE 40. 5. DESIGN LOADS: IN ACCORDANCE WITH F.B.C., 2014, 5TH ED. F.B.C. ROOF LIVE LOAD: 20 P.S.F. WIND LOADS: IN ACCORDANCE W/ F.B,C. 01 EDITION FOR 140 MPH REGION REFERENCING ASCE-7 INTERIOR PARTIONS: 5 P.S.F. PERPENDICULAR TO WALL FACE 6. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE W/ F.B.C. TRUSS MANUFACTURER SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. 7. LUMBER GRADE SHALL BE: A. HEADER, COLUMNS, BEAMS #2 S,Y.P. OVERBUILT FRAMING FB -1500 PSI B. WALLS, BLOCKING, MISC. #2 SPF C, SILL PLATES #S. Y. P. P, T, 8. ALL NAILS SHALL BE COMMON WIRE NAILS UNLESS NOTED OTHERWISE. 9, CHECK ALL DIMENSIONS WITH FLOOR PLAN BEFORE POURING FOUNDATION EXCLUDED 10. THIS STRUCTURE DESIGN EXTENDS TO ITEMS COVERED BY SSTD 10-99 EXCLUDED ARE FINISHES, NON- STRUCTURAL ITEMS, MISC, PARTS OVERHEAD DOORS, ROOFING, WALL WATERPROOFING WHICH ARE DESIGNED BY OTHERS. 11 CONCRETE FLOOR SLAB IS EXPECTED TO DEVELOP SHRINKAGE CRACKS. SUBMITTAL NOTES: 1, SPECIALTY ENGINEER FOR PRE-ENGINEERED WOOD TRUSSES SHALL BE A FLORIDA REGISTERED ENGINEER AND SIGNED AND 'SEALED SHOP DRAWINGS INCLIDINC CALCULATIONS SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO FABRICATIO OR ERECTION. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED IN COMFORMANCE WITH F.B.C. LATEST EDITION. 2, SHOP DRAWINr S SHALL ' INCLUDE TEMPORARY BRACING FOR ERECTION AND HANDLING AND PERMANENT BRACING AS REQUIRED BY SPECIALTY ENGINEER. TRUSS NOTES: 1. TRUSSES SHALL BE DESIGNED BY FLORIDA REGISTERED ENGINEER EXPERIENCED IN TRUSS DESIGN, PROVIDE SHOP DRAWINGS TO ARCIII rECT FOR APPROVAL PRIOR TO FABRICATION, SHOP DRAWINGS SHALL BEAR THE SEAL OF THE ENGINEER, 2. TRUSS FABRICATOR SHALL PREPARE A "FRAMING LAY -OUT" INDICATING THE LOCATION OF TRUSSES, BEARINGS TRUSS SPACING, PIrCH, BRACING LOCATION, AND OTHER INFORMATION DEEMED PERTINENT. ARCHITECT WILL PROVIDE TO FABRICATOR, UPON REQUEST, ONE REVERSE SEPIA FOR THIS USE. FABRICATOR SHALL SUBMIT "FRAMING LAY -OUT" TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION. UPON APPROVAL, FABRICATOR SHALL PROVIDE COPIES TO CONTRACTOR AND TRUSS ERECTOR FOR FIELD USE, 3. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER TRUSS HANDLING AND POPER TEMPORARY AND ERECTION BRACING. : 4. PERMANENT BRACING AS INDICATED ON DRAWINGS SHALL BE MINIMUM 2X4 DIMENSION LUMBER WITH 2--16D NAILS IN NAILS IN EACH TRUSS, UNLESS INDICATED OTHERWISE. ADDITIONAL BRACING AS REQUIRED OR RECOMMENDED BY TRUSS DESIGNER OR FABRICATOR SHALL BE INCLUDED AND INSTALLED. 5,TRUSS FABRICATOR SHALL BE RESPONSIBLE TO COORDINATE ALL TRUSS DIMENSIONS WITH FIELD CONDITIONS PRIOR TO FABRICATION, NOTIFY ARCHITECT IN WRITING IF ANY ADJUSTMENTS TO DRAWING DIMENSIONS ARE RECOMMENDED OR REQUIRED. 6. PROVIDE HURRICANE ANCHORS ANCHORS AS PER GOVERNING CODES AND RECULATION, AND AS INDICATED ON DRAWINGS, WED MEMUER SHEAfING� CONTINUOUS LATERAL BRNTI (CU) LATER UY TRUS`a DESIGN AND AS REQ'D. TRUSS FRAMING PLAN 2X4 W/ 2-16d NAILS AT EA. TRUSS. ¢b '2X4 DIACONAL BRACE (08) AT EA, ENO WALL CEILING -/11. & 0 2U'-0" O.C. MAX. INTERVALS ALONG LATERAL CONT, UOTTOM BRACE (DB) BRACE. 2x4 AS REQU BY TRUSS DESIGN & AS REQ'D IN TRU55 FRAMM, PLAN i ,'