Loading...
HomeMy WebLinkAbout819 Palmetto Ave 18-2491 (a) NEW SFH20L CITY OF L Building & Fire Prevention DivisionOiPERMITAPPLICATION FIRE DEPARTMEN 15 A Application No: Documented Construction Value: $'aNAQU(J_ YQ1074(.00 Job Address: 819 Palmetto Ave. Historic District: Yes7NoF] Parcel ID: 25-19-30-5AG-1001-0090 Residential[7 CommercialF] Type of Work: NewFv-(]AdditionF-]Alteration 1-1 Repair 11 Demo 1-1 Change of Useo Move 11 Description of Work: Build new 3 bedroom 2 bathroom replacement home 4 David LintonPlanReviewContactPerson. Phone: 407 590 9999 Fax: AName David & Marilyn Parker Street: 1810 Beacon Dr. City, State Zip: Sanford, Fl. 32771 Name Linton Enterprises Inc Street: P.O. Box 2707 City, State Zip: Sanford, Fl. 32772 Name: Chad Linn Street: P.O. Box 140024 City, St, Zip: Orlando, Fl. 32804 Bonding Company: n/a Address: Title: President . Email: david@lintonent.com Property Owner Information Phone: 407-312-6217 Resident of property? : yes Contractor Information Phone: 407 328 9786 Fax: State License No.: CBC 057 457 Architect/Engineer Information Phone: 407-252-6433 Fax: E-mail: Mortgage Lender: n/a Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a pen -nit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be perfon-ned'to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 61 Edition (2017) Florida Building Code Revised: January 1, 2018 Pennit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating consfiNction nd zoning. rf \p q5 10 7 Signature ofOwner/Agent' Date SighaAde ofContractor/Agent Date D AV I-- O6r)UVLCv V 4 n —\ P nt)bwner*ent's N Print Contractor/Agent's Nameme bl t, ..- / (— 5-- ;F/ 7 of NotrN--StKc/of Florid! Date 1<1MBERLYA. MORRISON MY COMMISSION # FF 992486 EXPIRES: June 12,2020 Borded TIvu Budget Notwy SeMc,es Owner/Agent is Personally Known to Me or Produced ID Type of ID PL P'L Signat of No [-!,tate of Florida DZt e F. JEANETTE ANDREWS 1 My COMMISSION *FF1 50391hl , " My COMMISSION *FF1 50391 E XPIRES. OCT 24 20 1 8XPIRES: OCT 24, 2018 Bonded throup I st State Insurance 1 P rSo V OwlContractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY ( of f,-7-,#A- Permits Required: 1zB=uwi—n' g, E =ec t-ri7caf,R N-0-c-lia-Ri7c-512" T J uml5i7ng2r n:u LRoLkiR, :7o-f-X'**' Construction Type: V6 Occupancy Use: JZ3 Flood Zone: Total Sq Ft of Bldg: 2-M9 5, Min. Occupancy Load: New Construction: Electric - # of Amps M Fire Sprinkler Permit: YesE] No [9' # of Heads APPROVALS: ZONING: 2-'('YJTILITIES: V L/ ENGINEERING: FIRE: 210 # of Stories: I Plumbing - # of Fixtures k I - Fire Alarm Permit: Yes F] No [R COMMENTS: t&t C D r, -t4-4C_k 'yVZW N L 1 y rn WASTE WATER: BUILDING: --.F- k, -,, 11- Revised: January 1, 2018 Pennit Application jt: CITY OF Building & Fire Prevention Division, SkNFORD PERMIT APPLICATION FIRE DEPARTMENT Application No: Documented Construction Value:$ 379,000.00 Job Address: 819 Pa-Imetto, Ave. Historic District: Yes VNoF 2519 30-5AG-1001-0000ParcelID: CommerciaResidentialV IF] Type I ofWork: New7 Addition[] AlterationFIRepair DemoF] Change of Use[3 Move El Bdild fie , w 3 bedroom 2 ath r o o rn I replacertIen I t horheDescriptionofWork: Plan Review Contact Person: David Linton, Title: President Phone: 407 590!9999 Fax: Email: deivid@lintonent.com Property Owner Information Name David & Marilyn Parker Phone: 407-312-6217 Street: 1810 Beacon.Dr,. Resident of pro ?,: yesperty City, State Zip:' Sanford,, Fl. 32771 Contractor Information Name Linton Enjerprises)nc Phone: 407 328 9786 Street P.O. Box 2707 Fax: City, State Zip: Sanford,, Fl. 32772 State License -No.: CBC 057 457 A.rchitect/Engineer Information Name: Chad Linn Phone: 407-252-6433 P.O. Box 140024Street. Fax: city, St9 Zip Orlando, Fl. 32804 E-mail: Bonding Company: n/a Mortgage. Lender: n/a Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR 1114PROVEMENTS11 To,, YOUR,, PROPERTY. A NOTICE OF COMMENCEMENT MUST - BE RECORDED AND POSTED ONTHE JOB SITE'BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING- YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated., I certify that no work or'installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws re ulating construction in this urisdiction. I understand 'that a separate permit must be secured 4or electrical . work, plumbin ' signs, wells, pools, 99 furnaces, boilers, heaters, tanks,-afid air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6 1h Edition (2017) Florida Building Code Revi,sed: January, 1, 2b 18 Pennit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the ennit is issued, inp accordance with local ordinance. Should calculated charges figured off the executed contract exceed, the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating const'uction nd zoning. 17 Signature of Owner/Agent' Date Sigp3tdre of Contractor/Agent Date D AV t NCO- l< E:'a- - N, P int,bwnerM Print Contractor/Agent's Namegent's Upme n Date KIMBERLYA. MORRISON MY COMMISSIOU FF 992436 EXPIRES: June 12,2020 of: FLO Bor&d 7?vu Budget NoWy Servkes Owner/Agent is---- Personally Known to Me or Produced ID —"— Type of ID P.L. SignaV-of Notat -State of Florida Ddte F. JEANETTE ANDREWS I My COMMISSION #FF150391 EXPIRES: OCT 24, 2018 Bonded through Ist State Insurance I Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: BuildingEl ElectricalF] Mechanicaln Plumbing[] Gas[] Roof F] Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures. Fire Sprinkler Permit: Yes F] No F APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads Fire Alarm Permit: YesE] NoE] UTILITIES M WA,STE WATER: FIRE: BUILDING: Revised: January 1, 2018 Permit Application COUNTY,OF 'SEMINOLE IMPACTFEE STATEMENT STATEMENT NUMBER: 18100006 DATE: August 07, 2018 BUILDING APPLICATION #: 18-10000674 BUILDING PERMIT NUMBER: 18-10000674 qol 0,7 L,( UNIT ADDRESS: PALMETTO AVE 819 25-19-30-5AG-1001-0090 TRAFFIC ZONE,:022 JURISDICTION: SEC:' TWP* RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE:, BLOCk: LOT: OWNER NAME: ADDRESS-: APPLICANT 14AME: DAVID PARKER ADDRIE.SS: 1810 BEACON DR SANFORD Ft 32771 LAND USZ' SINGLE FAMILY RESIDENCE TYPE USE: WORK,DEkRIPTION: CITY-,SANFORD 819 PALMETTO AVESPECIALNOTES. SFR CREDITS GIVEN FOR PREVIOUS HOM 0,N'PROPERTY FEE BENEFIT RATE UNIT 7 --------------------- CALC, UNIT TOTA I L DUE' TYPE DIST SCHED RATE, UNITS TYPE' ROADS-ARTERIALS N /J Single Family.Hous 70.5.00 ROADS -COLLECTORS 1.000, dwl unit 7'05.0,0Nlrg Single Family Housing .00 dwl unit Ao FIRE RESCUE N/A 00LIBRARYN Single Family Housing 54.00 1.000, dwl unit 54,00 SCHOOLS . N/A Single Family Housing 1.000 dwl unit 000.00PARKSN/A 0,0 LAWENFORCE N/A 00, DRAINAGE N/A CAEDIT.FEE$! SCI LIBRARY'R Single,Family Housing A,. 0 0 1 0'0 01 dwl un it' 54.0,0- S CI,SCHOOLS R v ous-ingsingleFamilH 9" bao.,00, 1.0:00 dwl unit 9 0,00 . n - I,RSc AD ARTERIALS R Si,ngle Family Hbubi:ng 705,00. 1.000 dwl.unit 705.:00- AMOUNT DUE 00 PERSONS 'AR' E ADVISED THAT THIS I S,A STATEMEN70F7EES DUE S,EMImnLE'COUNTY ROAn. WT1;?P /PVC(ITTV T TMI:,wT>v Amn fT UNDER THE I 1 11 1 -/" j ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS -0 1F T I H I E APPLIC I ANT OR I OWNER, TO APPEAL.THE CALCULATION OF ' AN,Y1OF THE ABOVkMENTIONED IMPACT FEES MUST BE EXERCISED BY,FILING A WRITTEN REQUEST WITHI14 45 CALENDAR DAYS OF THE DATE ABOVE, BUT NO LAtER TkAfl CERTIFICATEOF OCCUPA14CY OR OCCUPANCY. THE REQUEST,FOR REVIEW MUST MEET THE RE REMENTS OF THE COLY14TY LAND DEVELOPMENT CODE. COPIES OF RULES SUVIERNING APPEALS:MAY BE PICKED UPI, OR REQUESTED, FROM -THE BUSINESS'OPFICE: 1101 EAST FIRST STREETj1 SANFORD FL, 327711; 40T-'6_6,,5-T356'. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY ... OR CITY OF- SANFORD BUILDING DEPARTMENT, 1101 EAST FIRST SVREET SANFORD, FL 327,71 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD'REFERENCE THE COUNTY . BUILDING PERMIT NUMBER -AT THE*TOP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUI I LDING: PERMIT IS NOT IS-SUED,WITHIN 60 CALENDAR DAYS FROM THE DATE ABOVE 0;ijRevision0 Response to Comments 19L JUL t 2 2019 City of Sanford Building & Fire Prevention Division Ph: 407.688.5 150 Fax: 407.688.5152 Email: bu,ilding@sa,nfordfl.gov Permit# 17- 2q9 Submittal Date. Pr *ect Address: ?G 01 Contact: 0,U Ph: CrI 5JO Fax: Ema il: -Da Trades encompassed in revision: General description of revision: Por,,A T7,1 S & fQ 191. Building 11 Plumbing 11 Electrical Mechanical D Life Safety El Waste Water ROUTING INFORMATION Department Approvals El Utilities 11 Waste Water El Planning' Engineering El Fire Prevention 0' Building Application Number: 18-2491 Project Description: New SFR Job Address: 819 Palmetto Ave BUILDING DIVISION PLAN REVIEW COMMENTS Date: 07.11.2018 Contact Name: David Linton Contact Email: david(d)lintonent.com This is a general overview for code compliance in accordance with the minimum plan review required by the Florida Building Code. It is not a complete detailed review. The comments noted in this review must be addressed before the plans can be approved, Changes to plans shall be submitted on the same size format as the original submittal — changes in letter form are not permitted. All references to FBC Chapter I are as amended by City of Sanford ordinance viewable on our website atwww.sanfordfl.gov. Provide two copies of affected plan sheets andlor supplemental information as requested. Permit submittals will not be accepted without two copies, COMMENTS: 1. Please submit two (2) copies of Product Evaluation Reports for the spray foam insulation. Normally this can be provided by the insulation company performing the work. FBC 107 Any error or omission in this plan review shall not be construed to grant approval of any violation of any of the adopted codes or municipal ordinances of this jurisdiction. Ofrice meetinks with the plans examiner to discuss comments will require an appointment. arran2ed bv phone or email prior to arrival. Respectfully, Steve Fiorey, CBO Deputy Building Official I - This Instru ' ment Prepared By: Lonnie N. Groot, Esquire St'enstrorn, McIntosh, Colbert, Whigharn, P.A., 1001 Heathrow Park Lane, Suite 4001 Lake Mary,. Florida 32746 keiurn To: Ms. Christine Dalton Historic Preservation Officer Planning and. Developi-hent Services City Hall 300 North Park Avenue Sanford, Florida 32771 Tax Parcel r Identification, Nuriliber: 2540-30-6AGA 601 -ObbO. HISTORIC PRESERVATION BOARD OF THE CITY OF SANFORD DEVELOPMENT ORDER RELATING TO 01.9 SOUTH PALMETTO -AVENUE ANU ISSUING CERTIFICATE OF APPROPRIATENESS. The Historic Preservation, Board '(HP B) of the City :of Sanford issued this Development Order issuing a Certificate of Appropriateness relating to, and touching and concerning the following described property- 819 South Palmetto Avenue, which is assigned Tax Parcel ldefltifi I cati I on Number: 25-19-30 SAO-1'001.-.0090 assigned by the Seminole County Property Appraiser.. FINDINGS OF FACT Property OW'her/Appl icant: David E. Parker --and Maril n J Parkery 4810 Beacon Drive Sanford, Florida-32772-9719 Project.; To construct a on.e-$to,ry house (2,387 square feet), and one- story garage (1,091 square feet) with a lanai (484 square feet) connecting the, structures relative to property located at, 819 South Palmetto Avenue; Requested Development Approval: Theapplicant liasrequesti d.'Board approval to construct a one-story house (2,387 square feet) and one-story garage (1,091,,square feet) wit . h a lanai (484 square feet) connecting the.,structures relative to property located at 819 South, Pal rnetto Avenue. Additional Findings: The project is located at 819 South Palmetto Avenue in the Old Sanford Residential Historic District. The applicant has requested approval to construct a one-story house (2,387 square feet) and one-story garage (1,091 square feet) with a lanai (484 square feet) connecting the structures relative to property located at 819 South Palmetto Avenue. The approval set forth herein is based upon the ore tenus amendment to the application made during the course of the March 21, 2018 hearing. CONCLUSIONS OF LAW a). Pursuant, to Section 8.0 of Schedule "S" of the, City's Land Development Regulations as set forth in the, Code of Ordinances of the City of Sanford, the Historic Preservation Board has reviewed the proposed Certificate of Appropriateness and all matters relating thereto in accordance with the procedures for constructing, structures within historic districts as set forth in Schedule "S". b). The proposed construction is consistent with the purpose and intent of Schedule "S" and comply with the design guidelines in Schedule "S" and is in character with the surrounding Historic District, the required architectural standards, and will not adversely impact the Historic District. Specifically, Schedule "'S" states that: 1). Setbacks apply to. both principal and. accessory structures. Residential lot development shall have the following setbacks: A). Front yard.- Twenty-five feet (25)., B). Rear Yard 6- Two feet (2'). C). Side Yard: Five feet (6); provided, however, that when a side yard is the side yard setback shall be seven and one-half feet 6 75). D). In the case of an infill lot, the setbacks shall match one or the other of the existin"g setbacks on adjacent properties. E); To protect the pedestrian, character of the community and discourage front-load'ed garages, new curb cuts are not allowed.- within the . historic districts for properties that. have. alley accessi F). Dri 6 ays visible from the. righv wl A of Way' May, be surfaced with pourOd concrete,. pavers, gravel or.natural,lmulch, and. must be confined by appropriate curbing Driveways not visible from the right of- way such as those accessed from the alley may, 9 be, surfaced with. concrete, pavers, gravel and mulch..- G). New open porches, balconies, stoops and bay windows shall be permitted tpericro;ach i,htoth6.froht yi§,t.dohd'side-co"rn- e'r'sotbackb Aerifep.t(W), H)., , Where alleys are, available, new garages shall be detached and located at the rear & the lot, a,nd sh all be located no, closer than - thifty-five feet (35) ta the front property -line and curb cuts shaff.not be allowed. 1). Where a.1leys are,not available,11he garages shall be.detached and ilocated behind thp principal structure. Shared drivewa I ys are enco.uraged. J). Vehicles shall not be parked in the front, or side yards or in the right-of- way adjacent to any street- unless on an approved driveway, with a; permitted curb- cut. K). The new construction will comply with the, setback reqjjirements. detailed herein,. No new curb cuts have been propqsed The driveway on the south side of the property will uti.lize an existing curb cut.. The driveway on the,eastzlde of the property will be accessed from the, alley. 3 2). In the residential historic district, the scale and massing of new structures and their architectural elements shall be similar to the contributing structures of similar use in the Historic District. A). New, residential structures shall include a raised foundation to compliment the character of contributing structures in the Historic District t. B). In the Residential Historic District, new buildings shall not exceed thirty- five feet (35) in height. C). Primary residential entries for new structures shall face the street and shall not be recessed more than six feet (6') from the face of the primaryfagade. D). New development must incorporate mailboxes into the -design. Cluster mailboxes are prohibited in the historic districts. E). Building features within new construction shall be compatible with the color, material, and character of the property, neighborhood and immediate environment. F). A material consistent with the style of the structure shall enclose the undercroft of decks and foundations With spaced piers. The material shall be slightly recessed from the fagade of the building and shall not overlap or be flush with the outer surface of the original piers, supports or siding. G).- The use of synthetic materials is prohibited and unlawful for exterior wall surfaces with the exception of fiber cement siding, which may be approved by special Development Order for detached new construction only. H). Board trim at corners and around openings shall not exceed six inches 6") except at the front door surround which may be any size or configuration. 4 The scale m I . . and. arch itedWral r elements of the -proposed house and garage are I s,imilar to, 'the. contributing zt,rQqtures in, Ahe, Hi.storic- bistript. The. I U, in trute foundation Will be raised ta, coMpliment-the charopt0r,of :c6hMbi t r,uc J0 the Historl-C'District. The proposed, house and garage do. not exceed IhirtvJive.feqt,P5) in height, The proposed' new constru-ction i'& compatible with the color Material., and character of, the property, nei ghbOrholod, alnd immpd.iate efivjrqnment.:The poposed, P-9 W811 cladding i's fil*r cemient siding..Roard,' trim, at c ,proupd.-pponiqgt will notpmers: and ekeedsix in WIth, regard tq.pprches 6hd.,,ba*lQonios-',, Port flpotin --,,d groove, phd:'t hugt,rha-toh.ofidilh,al",, g shall be,;Wo.6dAqI.gup,pn porch,floodrigin h p pri6ritc tUrp, ing,shpl,( be d- -t d'- ndicul6t,40,theb_ui dih13). Pdrch,"flopr ,g!,s fa clde, or otientation'l, r m,the, rig y,,shall,,n ed with, material& C),. Porches: visible f o . ht7of4a ot"be ervids, sorth as _sdreenih Jibetgllcjs s or Masonry. gjq st, W0,04, 616minum' Mhyl, Temporary shade d'pvicesl must approved .',b means, of A certificate ,of yr - a p prop rilaternegs and must.n6t.beylisibllolfrorn the".r;ight,6f Way -when retracted'.,, D)., The,pr0pospd pq.rch,fl6qring,,wi 111, comply with. thelegy!ptions listed above. 4),. With, regard to, roofst igiblo from" th rightR6ofventsshall,. not be located on a p mary,:,pqq .0 vi p of:way. i I shape Ntute, design` B).1 -All..,pitched roof planes shall matth in, materia, dimension, polpr,and - t:other identifying,,features 5 C). Metal, roofs shall be standing seam, stamped, metal shingle, full corrugated, 5V crimp or must simulate the appearance,of standing seam. P. "" Metal roofs may be copper, galvanized, silver,or gray in dolor, or otherwise simulate a historic patina. E). , Gutters shall be made* of 'galvanized 'steel, wood, copper or painted aluminum and may be lhalf-rbUnd or low prbfile-box shaped" F); The proposed roof will ocimply with the requirement set. forth heroin. 5). With regard to windows and, doors; A). All now windows shall -have mullion profiles similar to contributing structures.- If'sirigle, hung or double -hung win dows, are placed in groupings,,. at trim iece of a, dimensi6rt of four inches (4") to, six fhches" shall separate thevindows. B), if a window contains divided, li_to-, true muntins orsitnulated true -divided lites (where a wood frame is glued to the exterior of the glass With :a very- high bond VHB) adhesive system) shall-bo used. If double pane windows are , i , nstalled, an internal shadow,bar shall also be used between the glasses. Inserted! or removable grillos and flat'grilles that do not replicate the profile and ch8raCteriSti, cs of the brijinbl window are9 prohibited on the exterior, of the window pane. The interior of -the wi , dow pin ane ma y have an inserted or removable grille provided that the grille is not flat and has a, profile.. C), Windows and doors shall be glazed in clear glass with no more than ten 10) percent daylight reduction. The, use of reflective glass and reflective film is. prohibited on all buildings. D). Windows shall be proportioned such that the height shall be equal to or greater than the width, with the exception of histon cally appropriate window groupings. 6 E). Rect6ngular windows shall be. casement and single or double hung; circular and h.exagon.al Windows may be fixed or pivot. F). Windows on new,houses. shall have definition.and a profile. Windows with flat profiles sha,11 be prohibited. G). New ga,raae doors may be constructed out of wood 'or fiberglass, and shall not exceed a maximum width Of n,ine feet. (9') for a single door on.front loaded garages and sixteen, feet (1-6) on all1eyrfacing garages. H). 16' garage doors must be architectural, carriage style: doors, that complementthe main- building, a.-rild,garage building. 1). The proposed, windows, and 'garage doors, comply with the regulations listed above. c).. To the.extent that a conclusion of law, as set -forth herein,also constitutes, a factual' finding,. then -such shall beIaken to be so as, part ofthis Development Order. d) The proposed Certificate of Apotopriatene8s, is, hereby found and determined to comply with the aforestated requirements. e). Additionally, the Certificateof Appropriateness sought is hereby found and determined to ber consistent with the ford Comprehensive, Plan and development of the,-'pr6pert as proposed would.bb--Ic , 6 sisterit with and in compliance toyIIf - e! i!" , - applicable land development regulations and'all bth,Or applicable regulations and ordinances as set'forth in the Code of Ordina_&e's of.M6'City of Sanford. ORDER NOW, THEREFORE, IT IS ORDERED THAT: The aforementioned application for a Certificate, of -Appropriateness is 7 APPROVED subject to the provisions hereof. 2). This Development Order granting approval of a Certificate of Appropriateness touches and concerns the aforedescribed property. 3). In addition to the foregoing, the property owner agrees to and the Historic Preservation approves the following: a). The bathroom window shall not be of prohibited glass block and shall be a clear transom windowas approved by City staff. b). The garage door, as presented in the documents on file with the City, are approved utilizing medal, materials as approved by City staff. c). The front door shall be subject to staff approval provided, however, that the drawing presented to the Historic Preservation Board is approved. Done and Ordered on the date first writte I n below,. As approved and authorized for execution by the Historic Preservation Board of the City of Sanford at its meeting of March 21, 2018. A TTES T. HISTORIC PRESERVATION BOARD OF THE CITY OF SANFORD Traci Houchin, City Clerk -P mmy Mil,011airman e: -::1 11 - c pro iunc to' March 21, 2018. Jennifer doiloway, Board Cler Ann1T1r)N I -q1r.K1ATHP1= R1 r)rW 1=nl 1 r)Wq- 8 JOINDER AND APPROVAL OF CONDITIONS BY PROPERTY OWNER IN WITNESS WHEREOF, the subject Property Owner has signed and sealed these presents the day and year written below and AGREES to all of the terms and condit , ions of this DevOloprheftt Ord.er the undersigned named: persons having, full authority to execute this document. ATTEST. I '] Signatur f Witness 1 G) Printed Name: Signature 6PV Printed,Name: STATE, Q.F,FLORII,DA COUNTY OF'SEMINOLE ) DAVID. PARKER David E. Parker 06- A-V PC-, 7- Marilyn J. Parker 1, the undersigned authority, a Notary, Public, in and for said State at Large who is authorized, to take acknowledgments, do hereby certify that David E. Parker and Marilyn J. Parker being duly sworn, acknowledged before me that they executed the foregoirtg.document, said persons being personally known to me, on this day,that they, being informed of the contents Of said instrument, they executed the same voluntarily. Given under my hand and official sea[ this 2:1 day of March, 2018. JENNIFER M. GOLLOWAY Fl--da 12rt& L2cb' Notary Public -Slile of Florida Commissidn#G(3162235 2 1 0 NOTARY !?,UBLIC My Conun. Expifes Nov 21, 2021 Mycommission expires: 9 This Instrument Prepared By: Lonnie N. Groot, Esquire Stenstrom, McIntosh, Colbert, Whigham, P.A. 1001 Heathrow Park Lane, Suite 4001 Lake Mary, Florida 32746 Return To: Ms. Christine Dalton Historic Preservation Officer Planning and Development Services City Hall 300 North Park Avenue Sanford, Florida 32771 Tax Parcel Identification Number: 25-19-30-5AG-1001-0090. HISTORIC PRESERVATION BOARD OF THE CITY OF SANFORD DEVELOPMENT ORDER RELATING TO 819-SOUTH PALMETTO AVENUE AND:ISSUING CERTIFICATE OF APPROPRIATENESS The Historic Preservation Board (HPB) of the City of Sanford issued this Development Order issuing a Certificate of Appropriateness relating to and touching and concerning the following described property: 819 South Palmetto Avenue, which is assigned Tax Parcel Identification Number: 25-19-30-5AG-1001-0090 assigned by the Seminole County Property Appraiser. FINDINGS OF FACT Property Owners/Applicants: David E. Parker and Marilyn J. Parker 1810 Beacon Drive Sanford, Florida 32771-9719 Project: For new construction elevation drawings relative to property locatedat 819 South Palmetto Avenue., Requested Development Approval: The applicant has requested Board approval for new construction elevation drawings relative to property located at 819 South Palmetto Avenue. Additional Findings: The project i s located at 819 South Palmetto Avenue in the Old Sanford Residential Historic District. The applicant has requested approval for new I construction elevation drawings relative to property located at 819 South Palmetto Avenue. The property is vacant lot previously which was previously improved with a 1924 Craftsman bungalow which was destroyed by arson fire in 2015. On March 21, 2018 the applicants received a Certificate of Appropriateness to construct a one-story house (2,387 square feet in size) and one-story garage (1,091 square feet in size) with a lanai (484 square feet in size) connecting the two structures. The applicants have submitted new elevation drawings which include the following revisions: 1). A grouping of two windows have been added in the gable area of the north and south elevations; 2). The proposed window designs have been changed to one over one as opposed to divided lites; 3). The proposed secondary door designs have been changed to single lite as opposed to divided lites; and 4). The glass block windows on the east and north elevations have been changed to single lite transoms. CONCLUSIONS OF LAW a). Pursuant to Section 8.0 of Schedule "S" of the City's Land Development Regulations as set forth in the Code of Ordinances of the City of Sanford, the Historic Preservation Board has reviewed the proposed Certificate of Appropriateness and all matters relating thereto in accordance with the procedures for constructing structures within historic districts as set forth in Schedule "S". b). The proposed construction elevations are consistent with the purpose and I comply with the design guidelines in Schedule "S" and are in character with the surrounding Historic District, the required architectural standards, and will not adversely impact the Historic District. Specifically, Schedule "S", states, with regard to windows and doors, that: 1). All new windows shall have mullion profiles similar to contributing structures -If single hung or double hungwindows are placed in groupings, a four to six inch trim piece shall separate the windows. 2). If a window contains divided lites, true muntins or simulated true - divided lites (where a wood frame is glued to the exterior of the glass with a very high..bond (VHB) adhesive system) shall be used. If double pane windows are installed, an internal shadow bar shall also be used between the glasses. Inserted or removable grilles and flat grilles that do not replicate the profile and characteristics of the original window are prohibited on the exterior of the window pane. The interior of the window pane may, have an inserted or removable grille provided that the grille is not flat and has a profile. 3). Windows and doors shall be glazed'in clear glass with no more than 10% daylight reduction. The use of reflective glass and reflective film is prohibited on all buildings. 4). Windows shall be proportioned such that the height shall be equal to or greater than the width, with the exception of historically appropriate window groupings. 3 5). Rectangular windows shall be casement and single or double hung; circular and hexagonal windows may be fixed or pivot. 6). Windows on new houses shall have definition and a profile. 7). Windows with flat profiles are prohibited. The proposed windows, comply with the regulations listed above. c). To the extent that a conclusion of law as set forth herein also constitutes a factual finding, then such shall be taken to be so as part of this Development Order. d). The proposed Certificate of Appropriateness is hereby found and determined to comply with the aforestated requirements. e). Additionally, the Certificate of Appropriateness sought is hereby found and determined to be consistent with the City of Sanford Comprehensive Plan and development of the property as proposed would be consistent with and in compliance to applicable land development regulations and all other applicable regulations and ordinances as set forth in the Code of Ordinances of the City of Sanford. ORDER NOW, THEREFORE, IT IS ORDERED THAT: 1). The aforementioned application for a Certificate of Appropriateness is APPROVED subject to the provisions hereof. 2). This Development Order granting approval of a Certificate of Appropriateness touches and concerns the aforedescribed property. Done and Ordered on the date first written below. As approved and authorized for execution by the Historic Preservation Board of thp rifv nf Rnnfnrcl nt ifQ moptinct nf Mnv 71 gniR 4 A TTES T.- HISTORIC PRESERVATION BOARD OF THE CITY OF SANFORD Traci Houchin, City Clerk Tammy Agnini, Chairman Date: Nunc pro tunc to May 23, 2018. Jennifer Golloway, Board Clerk ADDITIONAL SIG NATURE BLOCK FOLLOWS: R JOINDER AND APPROVAL OF CONDITIONS BY PROPERTY OWNERS IN WITNESS WHEREOF, the subject Property Owners have signed and sealed these presents the day and year written below and AGREE to all of the terms and conditions of this Development Order the undersigned named persons having full authority to execute this document. A TTES T.- Signature of Witness Printed Name: Signature of Witness Printed Name: STATE OF FLORIDA COUNTY OF SEMINOLE ) DAVID E. PARKER AND MARILYN J. PARKER David E. Parker Marilyn J. Parker ACKNOWLEDGMENT 1, the undersigned authority, a Notary Public, in and for said State at Large who is authorized to take acknowledgments, do hereby certify that David E. Parker and i Marilyn J. Parker being duly sworn, acknowledged before me that they executed the foregoing document, said persons being personally known to me, on this day that they, being informed of the contents of said instrument, they executed the same voluntarily. Given under my hand and official seal this. day of NOTARY PUBLIC My commission expires: 2018. THIS INSTRUMENT PREPARED BY: Name: David Linton Address: P.O. Box 2707 Sanford, Fl. 32772 NOTICE OF COMMENCEMENT State of Florida County of Seminole Permit Number: Parcel ID Number: flual-nar. GRANT MALOYY SEMINOLE COUNTY CLERK OF CIRCUIT COURT & COMPTROLLERBK. 9141 Ps lj--j5s (IF-9s) CLERK'S A. 201800600 RECORDED 1-15/29/21-113 01.'31-16 F-1-1RECORDINGFES $-10. 1" RECORDED BY I-idevore 0j 25-19-30-5AG-1 001 -0090 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) S1/2 of lot 9+a11 lot 10 Qlk 10 Tr 1 town of Sanford PB 1 Pg 59 GENERAL DESCRIPTION OF IMPROVEMENT: contruct new 3 bedroom 2 bath replace ment home at 819 Palmefto Ave. OWNER INFORMATION: Name: -David & Marilyn Parker Address: 1810 Beacon Dr. Sanford, FI. 32771 Fee Simple Title Holder (if other than owner) Name: CONTRACTOR: Name: Linton Enterpdses Inc Address: P.O. Box 2707 Sanford, FI. 32772 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(l)(b), Florida Statutes. Name: In addition to himself, Owner Designates Of To receive a copy of the Lienor's Notice as Provided in Section 713.13(l)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is I year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties. of perjury, I declare that I have read the foregoing and that the facts stated in it are true nd belief. Owner's - Signature DAIJ I tvAW- KFI-1— Owner's Printed Name Florida Statute 713.13(l)(9): " The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead." State of County of, 2 ? The foregoing Instrument was acknowledged before me this day of 20t by )[4 V-t r& I A J— Who Is persona I Ily known to me Name of person making stletern OR who has produced Identification 9 of Identification produced: KIMBERLYA. MORRISON MY COMMMSIO - N # FF 992486 EXPIRES: Jim 1Z 2020 BoWed TlVu Budget Notary Se*U 00 C-Z CN C.5 ca ci AGREEMENT BETWEEN OWNER AND CONTRACTOR FOR CONSTRUCTION AGREEMENT Made this 25th day of May, 2018, by and between David & Marilyn Parker of 1810 Beacon Dr. Sanford, Fl. 32771 Phone number 407-312-6217 hereinafter referred as OWENR/BUYER, and Linton Enterprises, Inc., hereinafter referred to as contractor. WITNESS that in consideration for the mutual covenants and agreements contained the Owner/Buyer and the Contractor agree set forth. The owner and the Contractor each bind himself, his successors, assign, and legal representatives to the party hereto and to the successors, assigns and legal representatives of such other party in respect to all covenants, agreements and obligations contained in this Agreement. Neither party to the Agreement shall assign this Agreement or sublet it as a whole without written consent of the other party. ARTICLE 1: WORK The Contractor shall perform all work required for the construction of a 3-bedroom 2 bath single family Residence with approx. 2073 square feet of living area on the Owner/Buyer's lot located at 819 Palmetto Ave. Sanford, Fl. 32771. Legal Description being 25-19-30-5AG-1001-0090 S/2of lot 9 plus all of lot 10 BLK 10 TR1 Town of Sanford PB 1 Pg 59 Parcel Identification Number: 25-19-30-5AG-1001-0090 ARTICLE 2: COMMENCEMENT The work to be performed under the terms of this Agreement shall be commenced within fourteen 14) days of receipt of building permit from governmental agency. The work is to be completed within 365 days from day of commencement. ARTICLE 3: All the limits stated in the Contract Documents are of the essence. If the work is delayed at any time in the progress of the work by changes ordered in the work, by labor disputes, fire, unusual delay in transportation, unavoidable casualties, causes beyond the Contractors control or by inclement weather, then the contract time shall be extended as reasonable. ARTICLE 4: CONTRACT SUM The owner shall pay the Contractor for the performance of the work, subject to additions and deductions by change orders, as provided in the general conditions, the Contract sum of: $ 379,000.00 If Notice of Commencement is not received within 30 days of the signing of Agreement, this Contract shall become void. ARTICLE 5: PAYMENTS Owner shall obtain financing from a lending institution. Owner shall make applications within 20 days from signing of Agreement and shall make diligent and sincere efforts to comply with information needed from institution and in successfully obtaining financing. Payments shall be as follows: a. Deposit upon Signing Agreement 37,900.00 Funds from financial institution (approx) $0.00 C. Balance of Deposit upon Loan Approval $0.00 d. TOTAL 379,000.00 Payments to be made as per draw schedule. 10% upon signing this proposal, 10% when slab is poured, 10% when block walls are poured, 25% when roof is dried in, 15% when rough wiring is complete, 10% when drywall is hung, 10% when exterior fmishes are installed,5% when cabinets are installed Balance within 5 days of issuance of C.O. from building dept. ARTICLE 6: FINAL PAYMENT The owner shall make final payment within five (5) working days after completion of the work. Completion is determined by final inspection and receipt of Certificate of Occupancy from the appropriate governmental agency. Prior to final payment, a waik-through inspection shall be made, in accordance with Article 8, with the Owner, Contractor and any Real Estate Agent involved. Final payment shall be made in full prior to occupancy. ARTICLE 7: INTEREST Payments due and unpaid under the Agreement and Contract Documents shall bear interest from the date payment is due until paid at 12%. ARTICLE 8: INSPECTIONS A. the Owner shall make on -site inspections with Contractor as follows: 1 Lot inspection before signing Agreement Objectives: a. Review lot elevations and any fill requirements b. Discuss placement of house on lot c. Discuss landscape design for clearing needs d. Mark trees to remain on lot Walls up and roof is dried -in Objectives: a. Review layout b. Measure for Drapes c. verify outlets, including TV, telephone and electrical 3. Primary finishes are complete Objectives: a. Verify lights are correct b. Inspect finishes c. Make punch list of incomplete or incorrect items except landscape and carpet 4. Final Inspection Objectives: a. Review Punch List for incompletion b. inspect construction OWNER INSPECTIONS K YES NO B. Governmental inspections — These inspections are made by the appropriate Building Department to verify construction standards are in compliance as set forth by the Florida Unified Building Code and other standards. ARTICLE 9: CLOSING The closing of the Agreement shall be held at the office of: n/a. ARTICLE 10: CONTRACT DOCUMENTS The Contract Documents shall consist of: 1 . The Agreement between Owner and Contractor for construction 2. Specifications 3. Drawings 4. Plot Plan 5. Change orders (if Used) 6. Draw Schedule 7. List of Allowances 10.1 These documents from the Agreement and the Requirements of any one shall be binding as if required by all. The intent of the documents is to include all actions and items necessary for the proper execution and completion of the work and to include the terms and conditions of the payment thereof. 10.2 The Contract Documents shall be signed by the Owner and Contractor 10.3 The Agreement for construction represents the entire integrated agreement between parties hereto and supersedes ail prior negotiations, representations or agreements, either written or oral. ARTICLE 11: CHANGE ORDERS The Owner, without invalidating the Contract, may order changes in the work consisting of additions, deletions and modifications, the Contract Sum and Work Time being adjusted accordingly. ALL such changes in the work shall be authorized by written Change Orders signed by the Owner and the Contractor. All Change Orders are to be paid in full at the time the Change Order is signed and before such work is commenced. If Change Orders not paid before change is necessary in construction, so as to interfere with progress, change will not be included. ARTICLE 12: COLOR SELECTIONS The owner shall make necessary color selections and have such selections completed no later than one (1) Month after commencement of construction. Color selections shall be made at: Site. ARTICLE 13: INSURANCE 13.1 The Contractor will maintain such insurance as will protect him from claims for damages because of bodily injury, including death and from damages to property which may arise out of or result from the Contractor's operations under the Agreement. 13.2 Owner shall purchase and maintain property insurance upon the entire work at the site to the full insurable value thereof, at the time of closing. ARTICLE 14: CONTRACTOR 14.1 The contractor shall supervise and direct the work. The contractor shall be responsible for all construction means, methods, sequences and procedures and for coordinating all portions of the work under the contract. 14.2 Unless otherwise specifically noted, the Contractor shall provide and pay for all material, labor, equipment, tools and other facilities and services necessary for the proper execution and completion of the work 14.3 The Contractor shall pay all sales, consumer, use and other related and similar taxes required by law. 14.4 The Contractor shall secure all permits, fees and licenses necessary for the execution of the work. 14.5 The Contractor shall give all notices and comply with all laws and ordinances of any public authority bearing on the performance of the work. ARTICLE 15: OWNER 15.1 Owner shall not interfere with the workmen during working hours and all transactions will be discussed with the Contractor only. 15.2 Owner will make appointment with Contractor to walk-through property once construction commences. 15.3 Owner shall be responsible for specific cost. Pool and screen enclosure if applicable. And all materials /labor allowance listed in this contract ARTICLE 16: CANCELLATION OF CONTRACT 16.1 Contract was entered upon assumption Buyer/Owner would qualify for institutional financing at the maximum interest charged at the prevailing interest rate. After prudent and diligent efforts to obtain financing, should Buyer/Owner not qualify, Contract Gan be voided upon written notice to Contractor from financial institution. Owner shall be entitled to refund of deposit with the exception of $3000.00 to cover the Contractor's expenses incurred. 16.2 Should Owner breach Contract or halt construction once construction has begun, Contractor shall be entitled to all expenses incurred by him under Contract plus fifteen (15) percent of total cost as liquidated damages. ARTICLE 17: WARRANTY The Contractor warrants to the Owner that all materials and equipment incorporated in the work are new unless otherwise specified, and that all work is of good quality, free from faults and defects in conformance with the Agreement and Contract Documents and the Florida Unified Building Code. All work not so conforming to these standards may be considered defective. Contractor reserves the right to substitute like material and brands and like items during construction due to supply availability. The Contractor shall correct any work that fails to conform to the requirements of the Contract Documents and the Florida Unified Building Code where such failure to conform appears during the progress of the work, and shall remedy and defects due to faulty materials, equipment or workmanship which appear within a period of one (1) year from receipt of Certificate of Occupancy from the appropriate agency, or within such longer period of time as may be prescribed by law or by the terms of any applicable special guarantee required by the Contract Documents. The provisions of the Warranty apply to work done by Subcontractors as well as to work done by direct employees of the Contractor. ARTICLE 18: SPECIAL CLAUSES None This agreement is understood to be legally binding contract. If not fully understood, please see an attorney prior to signing. WITNESS WITNESS V/111U & M V- (17 Executed by Owner/ Buyer on nlas-1 IS — OWNER L Ecl,=—(OWNER) Executed by Linton Enterprises, Inc on David Linton, President SPECIFICATIONS Exhibit "B") Owner: David & Marilyn Parker Phone: 407-312-6217 Contractor: Linton Enterprises, Inc. Phone: 407/328-9786 Street Address 819 Palmetto Ave. Sanford, Fl. 32771 GENERAL: Construction shall be in compliance with sound building practices and in conformity with local building and zoning ordinances. Construction to be not less than the minimum requirements of the Florida Unified Building Code. Plans shall consist of site plan, foundation plan, floor plan, elevation plan, electrical plan, truss plan, cabinet and vanity detail and typical wall detail plan. CHANGE ORDERS: All change orders shall be in writing, signed and dated by both Owner and Contractor. The cost increase or decrease shall so be written on the change order. Contractor reserves the right to collect any increase in cost from Owner after change order is completed. All costs for change orders shall be paid in full to Contractor prior to the issuance of the Certificate of Occupancy. IV. SUB -CONTRACTORS: All sub -contractors shall be approved by Contractors and must furnish Workman's Compensation and Liability insurance certificates prior to performing any work. Owner assumes all risks, liability and warranty claims from any sub -contractors not approved by Contractor. 1. SITE CLEARING AND SOIL CONDITIONS: A. Owner warrants that the building site is suitable for the erection of a single family residence. If Owner elects to have a site evaluation by a Registered Geotechnical Engineer, he shall provide a copy of the report to Contractor prior to commencement of site preparation and construction of the dwelling. The Owner shall bear the cost, if any, to repair any deficiencies that should make the site unsuitable for construction. Soil conditions shall meet a minimum 95% compaction rate. B. Site preparation and clearing is included in the contract price. C. Lot fill shall be considered a change order with Owner bearing cost of same. Owner shall notify Contractor if lot fill is desired prior to completion of the erection of foundation walls. 2. FOOTINGS: A: Footings shall be 10 inches deep by 16 inches wide with 2 steel bars 5/8 inches in diameter. Concrete is to be ready mix with a minimum 2500 p.s.i. rating. 3. FOUNDATION WALL: A. Foundation walls to be constructed of concrete masonry units (blocks). Foundation wall height to meet minimum local building ordinances. Max 32" 4. SLAB: A. Foundation shall be filled with clean fill dirt and compacted. Foundation fill to be a maximum of 32 inches deep and any fill needed for any and all heights above 32 inches shall be considered a change order with Owner bearing cost of same. B. Soil shall be treated for subterranean termites. Stab shall be reinforced with 6x6x#1 0 gage wire mesh or fiber mesh concrete. Expansion joint shall be used where appropriate and vapor barrier shall consist of 6ml visqueen. Concrete shall be 4 inches thick and be a minimum 3000 p.s.i. rating. 5. EXTERIOR WALLS A. Exterior walls to consist of masonry block units to the height of 10' above finish floor, with shown pours and bond beams as per plan. 6: ROOF TRUSSES A. Shall be pre-engineered with top, bottom and supporting chords to be 2x4 yellow pine unless otherwise specified in truss engineering specifications. Truss spacing shall be 24 inches on center. 7: ROOFING A) Roof decking shall consist of 7/16 4 ply plywood with ply -clipping in between all 24 o.c.inch trusses B. Subroof shall consist of modified bitmus peel and stick underlayment. . C. Finish roof shall be 26 ga.. 5 v style metal roofing finished in galvalume finish 8. INSULATION A. Frame walls shall have R-1 3 fiberglass insulation B. Ceilings shall have R-20 icynene open cell foam insulation over living areas, ceilings. C. Masonry walls shall have r-6 foil reflective D. Walls of bathrooms and laundry room shall be R-1 1 for sound 9. WINDOWS AND SLIDING GLASS DOORS A. Windows shall be Better Built or equivalent single hung, low e glass, double pain, vinyl frames with screens and locking devices B. Window frames to be white, colonial style or that shown on elevation plan. 10. WALLS AND CEILINGS A. Shall consist of 1/2 inch thick gypsum boards with taped joints and beaded corners. B. Ceilings to be sag resistant board with Ievel4 smooth finish. C. Walls shall be level 4 smooth finish D. Wet shower and tub areas shall be 1/2" concrete backer board r___ - ' - "___ __ - E. Exterior lania and entry porch ceilings shall be 1x4" pine tongue and groove, bead board, painted. 11. ELECTRICAL A. Services shall be 200 amperes B. All wiring except main services and major appliances shall be copper wire with standard switches and receptacles per electrical plan. Main Service and major appliance wiring shall be aluminum. C. All electrical fixtures including but not limited to light fixtures, fans, chimes and fluorescent fixtures shall be part of the lighting and fan allowance. D. Electrical outlets and switches to be white decora. E. Provide catv wiring as per plans 12. PLUMBING A. Plumbing water service line and all sewage disposal lines to be schedule 40 PVC. B. All interior water lines to be in cpvc. C. All plumbing fixtures and hose bibs located as shown on floor plans D. Faucets and valves to be Moen Monticello, brushed nickel finish. E. Water closets to be Gerber two piece, elongated with seat. F. Lavatories to be Kohler China under mount. G. Kitchen sink to be supplied by owner. H. Supply hot and cold water to toilet in master bathroom. I . Master tub allowance $ 1000.00 J. on demand Rheem gas water heater. 13. DOORS AND TRIM A. Exterior doors shall be Fiberglass with insulated glass. B. Interior doors shall be Elite six panel pre -primed C. Bifold closet doors shall be Elite six panel pre -primed D. Base and casing to be finger jointed, colonial E. Specialty trim only where denoted on floor plan or wall detail F. Locksets to be Kwikset Lido series or equivalent with all exterior doors double bored for single key deadbolt. G. Locksets to be Satin Nichol finish H. All windows trimmed with wood sills. 14. CLOSET SHELVING A. Closet shelving to be designed and installed by owner within $ 1000.00 Allowance including all materials and labor. 15. CERAMIC TILE A. All tile to be selected from Master tile distributors. B. Tile on shower and tub walls to be 6x6 bright finish. C. Window sills to be wood. D. All wall tile over 1/2 inch wonder board 16. PAINTING A. Paint Manufacturer shall be Sherwin Williams or equivalent B. Masonry walls to be covered with stucco to be primed with seal -cote sealer or equal before painting. C. Wood facia shall receive two coats of oil or acrylic stain. D. Interior painted wood shall receive primer coat and finish coat in oil or acrylic semi -gloss enamel. E. Walls shall receive two coats in latex finish F. Walls to be papered shall receive one coat oil primer and sanded smooth. G. Knockdown ceilings shall be painted with Hi -hide latex paint. H. Bath ceilings less than eight feet high shall receive an oil or acrylic semi -gloss finish. 17. CABINETRY A. All cabinetry, vanities and tops shall be selected by Owner and subject to allowance specifications. 18. FLOORING A. Owner to select flooring subject to allowances according to flooring detail as shown on floor plan. 19. HEATING AND AIR CONDITIONING A. System designed including load calculations B. All duct work to be flex duct or rigid duct as required by installers. All joints shall be taped, stapled and covered with duct mastic. C. Air handler and heat pump shall be Carrier equipment or equal Heat pump shall be high efficiency, 15.00 S.E.E.R. minimum. D. Return and supply grill shall be metal and adjustable. 20. APPLIANCES A. Owner to select appliances subject to allowance specifications. 21, FIREPLACE A. N/a 22. WALLPAPER A. N/a 23. LANDSCAPE, FINAL GRADING, SOD AND IRRIGATION SYSTEM A. Contractor to do final lot grading B. Landscaping, irrigation materials with in allowances. 24. DRIVES, SIDEWALKS AND LEAD WALKS A. Paver drive from garage to existing curb cut on south entry of garage. Concrete drive for rear entry garage entry 25. POOLS AND SCREENS ENCLOSURES A. n/a 26. SPECIALITY ITEMS A. Hardi non -vented soffits and wood facia 27. Allowances A. Driveway Materials/labor $ 4000.00 B. Landscaping materials/labor $ 5000.00 C. Permit and impact fees $ 3,200.00 D. Cabinets and countertop allowance $ 19,500.00 E. Electric fixtures allowance $ 1500.00 F. Plumbing Fixtures allowance $ 2000.00 G. Master Tub Allowance $1000.00 H. Appliance allowance $ 0.00 1. Tile materials allowance $ 6850.00 J. Tile labor allowance $ 8600.00 K. Carpet Flooring allowance $ 0.00 L. Lot fill and incidental allowance $ 260 cy M, Faux stone materials and labor allowance $ 4000.00 t? N. Landscaping and irrigation materials and labor $ 5000.00 DATE Contracti OWNER 0 , I . 1 r REQUIRED INSPECTIONSEQUENCE RPO Address: BuiLDING PERMIY Min Max ns ection Descrietion 10 Footer 20 Stemwall 30 Foundation/Form Board Survey 30 Slab 40 Lintel 50 Sheathing — Roof 50 Sheathing — Wall 60 Frame 70 Insulation Rough 80 1000 Insulation Final 1000 Final Single Family Residence R,64F ,RM Min Max Imgection Descri2tion 10 Roof Dry In 1000 Final Roof ELECTRICAL PERMIT Min Max Inspection Description 10 Electric Underground 10 Footer / Slab Steel Bond 20 Electric Rough 30 Pre -Power Final 1000 Electric Final Min Max Insl2ection Description 10 Plumbing Underground 10 1000 Plumbing Sewer 20 Plumbing Tub Set 1000 Plumbing Final 7 - - - - - - - - - - -- :7- M, iEC HIANICA'',,, PERIM111T Min Max Inspection Description 10 Mechanical Rough 1000 Mechanical Final Max Inspection DescriptionMin 10 Gas Underground 20 Gas Rough 1000 Gas Final REVISED: June 2014 DEC 05 201 PERMIT APPLICATION Application No: - f ?il - P- 7 '_ I / — Documented Construction Value: Job Address: - F t 7 0 -e -7-11,0 A V, — Historic District: Yes[] NoD Parcel ID: Residential El Commercial 11 Type of Work: New ar Addition n AlterationEl RepairEl DemoEl Change of UseEl MoveEl Description of Work: 5,T411 6'1 5_ Pir4<7 Plan Review Contact Person: Phone: 5.11-iv00,7Fax: Name Street: City, State Zip: Email: t 5tCvll R 'O— el (y'- & Property Owner Information Phone: Resident of property? : Contractor Information V -.?9 Phone: 5- t7- i't OP7Name Street: Fax: City, State Zip: .1- FO fZ - 5 2 ;7,7-2- State License No.: Architect/Engineer Information Name: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6' Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that maybe found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owl,r/ Agent Date X- f' 14 , , - -e - ---r6 a--t- Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Signature of Contractor/Agent Date or/Agent Name PrJ_ intntract 's la A,4 Signature qLN gLaBLSt4 e &F i L_ IRL ANNETTE BLAND Notary Public - State of Florida Commission # GG 060623 My—Ur1Vr9Y6Cft49yaKM=91 Me or BELOW IS FOR OFFICE USE ONLY ' Permits Required: Buildin D Electrical El Mechanical [:1 PlumbingEl Gas r7l ' 9 q Roof El Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes El No R #of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Fire Alarm Permit: Yes [I No [I WASTE WATER: BUILDING: jr ALAN STEVERSON PLUMBING, INC. P.O. BOX 336 SANFORD, FLORIDA 32772 407) 519-4067 SEP 112018 BUILDING DIVISION PERMIT APPLICATION Application No: 17 1 41:7 Documented Construction Value: $ job Address: -e Historic District: Ye . s . D NOO Parcel ID: Residential 0 CommercialEl Type of Work: New Addition [I Alteration D RepairEl Demo [I Change of UseEl MoveF1 Description of Work: 7-4 t I ;.p Plan Review Contact Person: Title: X, lie, Phone: Fax: Email: A 6 6 e- Property Owner Information Name Street:- z Phone: Resident of property? : City, State Zip: yiv C ractor Informationont Name 3T P1,66 X-4 Phone: L-+-r 7— 5 t -1 t' 6,67 7 Street: Fax: City,StateZip: FL 7 -2 State License No.: Architect/Engineer Information Name: Street: City, St, Zip: BondingCompany: Address: Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.' A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6' Edition (2017) Florida Building Code 4- ", NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713 The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID 7J,&_ I — / 7 — 1Y Signature of Contractor/Agent Date P/t n)Contractor/Agenfs Name Signature of Notary -State of Florida Date ANNETTE N1 8LAND N0t81Y Pubic - State of Flodda Corr. ssion t GG 09Co n to Me orContractMyCO so 1 1'a_,_i' EC`CVProduce BELOW IS FOR OFFICE USE ONLY Permits Required: Building El Electrical 11 Mechanical 0 Plumbing F1 Gas 11 Roof 11 Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes [] NoFJ # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Fire Alarm Permit: Yes []No [] WASTE WATER: BUILDING: ALAN STEVERSON PLUMBING, INC. P-O.BOX 336. SAJqfORDYL., 32772 407) 349-2030 ASTEVERSONPLBG@YAHOO.COM Name/Address LINTON ENTERPRISES INC. P.O. BOX 2707 SANFORD, FL. 32772-2707 Da te Estimate No. L 411 —J Project Description Qty Rate Total 819 S. PALMETTO, SANFORD, PARKER RES. AS PER PLANS 3- LAVS. 2- HANDI CAP WATER CLOSETS I- SHOWER VALVE (NO PAN) 1 - TUB AND SHOWER 1- WASHING MACHINE BOX 1-KITCHENSINK (OWNER, SUPPLIES) 2- REFRIGERATOR BOXES 1- TANKLESS WATER HEATER ($1000.00) 1 - ROMAN TUB ($1000.00) PVC SEWER CPVC WATER NO PERMIT FEE IN BID BRUSHED NICKEL OVER CHROME) $970.00 MORE TOTAL BID 11,850.00 11,850.00 Total $11,850.00 Legal Description South half of Lot 9 and all of Lot 10, Block 10, Tier 1, Town of- Sanford, according to the Plat thereof, as, recorded in Plat Book 1, page 59, of the Public Records of Seminole County, Florida. A Q 6 R E V I A T 1 0 N L Q E N Q P R.M PERMANENT REFERENCE MONUMENT C.M. - CONCRETE MCNUMENT EL. - ELEVAPON CONC. CONCRETE W.M. WATER METER P O,E POINT OF COMMENCEMENT P.B. - PLAT BOOK A/C AIR CONDITIONER C.L.F. CHAIN UNK FENCE F.H. FIRE HYDRANT P.C. POINT OF CURVATURE Pg. PACE TYP. TYPICAL i W.F, WOOD FENCE N & D NAIL AND DISC P.R.C. POINT OF REVERSE CURVATURE N.R . NON -RADIAL U. E. UTILITY EASEMENT C & G CURB & GUTTER B . M. BENCH MARK P.C.C. POINT OF COMPOUND CURVATURE RAD. RADIAL D. E. DRAINAGE E#SEMENT CATV CABLE TELEVISION RISER PVMT. PAVEMENT PJ POINT OF TANGENCY R. RADIUS F.F. FINISHED FLOOR TELE TELEPHONE RISER F.B. FIELD BOOK P.I., POINT OF INTERSECTION L. ARC LENGTH B.S_ BUILDING SETBACK TRANS TRANSFORMER PAD M.H. MANHOLE P.C.P. PERMANENT CONTROL POINT 6 DELTA C.B.S. CONCRETE BLOCK STRUCTURE L.P. LIGHT POLE A) ACTUAL P.O.L. POINT ON LINE R. P. RADIUS POINT P) PLAT P.P. POWER POLE 1. D. IDEN-RFICAT10N C.B. CHORD BEARING R/W RIGHT-OF_WAY M MEASURED EM ELECTRIC METER FND FOUND T.B. TANGENT BEARING CENTER LINE C CALCULATE R/W RIGHT OF WAY EDP EDGE OF PAVEMENT Survey Notes: Certified Correct To: 1. "NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER". Claudia Contreras Virgen 2. BEARINGS SHOWN HEREON ARE RELATIVE TO THE EAST RIGHT—OF—WAY LINE OF PALMETTO AVENUE AS BEING S 00*14'35" E AS SHOWN,BEING ASSUMED. 3. THE "LEGAL DESCRIPTION" HEREON PER THE PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA. 4. THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT OR OPINION OF TITLE. NO INSTRUMENTS OF RECORD REFLECTING EASEMENTS, RIGHTS —OF —WAY, AND/CIR OWNERSHIP WERE FURNISHED TO THIS SURVEYOR EXCEPT AS NOTED. 5. ALL BEARINGS AND DISTANCES SHOWN HEREON ARE PER THE DESCRIPTION AND ARE CORRECT AND IN AGREEMENT WITH THE FOUND AND SET MONUMENTS AS MEASURED IN THE FIELD UNLESS OTHERWISE NOTED. 6. ACCORDING TO THE NATIONAL FLOOD INSURANCE PROGRAM, FLOOD INSURANCE RATE MAP (FIRM) COMMUNITY PANEL NO. 12117CO07OF EFFECTIVE DATE: SEPTEMBER 28, 2007 THIS PROPERTY LIES IN ZONE "X" LYING OUTSIDE THE FLOOD ZONE. 7. NO UNDERGROUND UTILITIES, FOUNDATIONS OR IMPROVEMENTS, IF ANY, Surveyor's Certification: HAVE BEEN LOCATED EXCEPT AS SHOWN. 8. THIS BOUNDARY SURVEY MEETS OR EXCEEDS THE HORIZONTAL CONTROL I hereby certify that the attached "Boundary Survey" of the ACCURACY OF 1/7500 BEING A SUBURBAN SURVEY. hereon —described property is true and correct to the best of my knowledge, information and belief as done under my direction in the 9. ELEVATIONS SHOWN HEREON ARE BASED ON THE NORTH AMERICAN VERTICAL DATUM OF 1988 field on September 01, 2018. 1 f rt certify that this "Boundary AND SAID ELEVATIONS ARE BASED ON BENCHMARKS SUPPLIED BY THE SEMINOLE COUNTY SURVEY SurveV' meets the Standards of Pr c,ic ;cs:s'6t forth in chapter DEPARTMENT S FOLLOWS: 5J-17 of the Florida Adminis rc I a.) MARK # 140 TOP OF C.M. WITH BRASS DISC. ELEV. = 23.906 b.) MARK # 142 TOP OF C.M. WITH BRASS DISC. ELEV. = 14.644 Date: 09/01/18 NOT VAUD *1 THOU T SHEET 2 'A Project No. 542—DMP-001 Professional Surveyor and Mapper Dwg file: 542—OMP-001 Florida Registratian No. 5599 DRAWN: WCE Boundary Survey David kParker & Marilyn J. Parker KLE Surveying Napping, Inc. SHEET APPROVED: WCE 153 Sir Topaz Lane NorthDATE: og/ol/18 81g Palmetto Avenue Section 25, Township ig South, Range 3o East Lake Mary, FL 32746 OF 2 SCALE: N/A city of Sanford, Seminole County, Florida 407) 402-2331 License Business # 7899 r FOUND CONCRETE MONUMENT IN WELL BOX NO I.D. C) coI'J C co f f n 0 M Project No. 542-DMP-001 Dwg file: 542-DMP-001 ftm&&z &=-v NOT VAUD WHOUT SHEET.1 CIL 8th STREET 66' PUBLIC RIGHT—OF—WAY PER PLAT) 2AVU R-QAQ 8' ADDITIONAL R/W PER PLAT IOUND 1"— 7OUND 5/8" IRON PIPE N 89053'32" E 116.91' (M) IRON PIPE 149 NO I D. 117' (P) NO I.D. 0) 31 K 46 V) A Ul i3LOOK 1101, 11k' A'A I Q -AFOUND1/2" LnSET IRON ROD & 117' (P) IRON ROD 0) 0 M CAP CAN NOT P.B. 5Y 1, CAP rn READ 89*52'2' E 116 73' (M) LB J 789011 k' COMET 6' WOOD - 7' WALK 0. 4' OFF lc FENCE " I6' WOOD 77777=7 4 3' c8 (0.5- OFF) SANITARY FE 77NCE 0.5' OFF) a ""'2 L'--T 2 SEWER j aBL,- K TEZR MANHOLE 116 'i A, -,Pr, C" K DTOWN, JOF 'FORLV 12.5' PA --S ;0P. B. 1 PAG //`Z/Z23.98'Z 6.8, 0 C WOOD 6"c" TE BLOCK;! U-nLI STEMWALL 16. POLECONCRETEBLOCKF. F. STEMWALL CD 30.7 F. F. = 30.7 .8, 12.5' F,5.9- L,--, T , 01, //1 0 4.0 ;a BLOC-k. , 0, TEIR / > S OF E 4 A, %4 o g GES 110ZRB4 'ES 59PAG Cil 0 CONCRETE 0 S T WA I E 0 WA K SET !A5 '30.3" IRON ROD 7.:':: (P) PCAP LB # E (MLB # 71899 N 89*5332 116.66 14 CIL 9th STREET 66' PUBLIC RIGHT—OF—WAY PER PLAT) PAVED ROAD DRAWN: WCE Boundary Survey KLE Surveying SHEET APPROVED: WCE David E. Parker & Marilyn J. Parker AJQ1 Mapping, Inc. 2DATE: 09/01/18 819 Palmetto Avenue 153 Sir Topaz Lane North Section 25, Township ig South, Range 3o East Lake Mary, FL 32746 OF 21. SCALE: 1 = 30' City of Sanford, Seminole County, Florida 407) 402-2331 License Business # 7899 IBLUE MARLIN ENGINEERING September 20, 2018 Project No. 18-196 David Linton Linton Enterprises Inc. 417 Tangelo Drive Sanford, FL 32771 Construction Materials Testing Services, Progress Report No. 1 819 Palmetto Ave. Sanford, FL Dear Mr. Linton: As requested, Blue Marlin Engineering, LLC performed the following construction materials testing services at the above referenced project. 1. Soil Sampling 2. In -Place Density Testing 3. Modified Proctor Testing The results of the tests are summarized on attached sheet 1 and modified Proctor test number 195 1. We trust this information is sufficient for your needs. If you have any questions, please do not hesitate to contact the undersigned. Sincerely, Blue Mar"tWAIA LLC Certifi %, iFori ioif4umber 29218 0 73262 cc TAA A-, 0sciS Pre id GsNL Florida LiJeZm.awe www.bluemarlinengincering.com 102 Drennen Road, Suite 13- 10 Orlando, Fl 32806 Phone: 407-217-4464; Fax: (321) 710-2483 ul Blue Marlin Engineering, LLC 102 Drennen Road, Suite B- 10 Orlando, FL 32806 Telephone 407.217.4464, Fax 321.710.2483 David Linton Linton Enterprises Inc 417 Tangelo Dr Sanford, FL 32771 IN -PLACE DENSITY TEST REPORT 819 Palmetto Ave Sanford, FL General Test Location: Building Pad Fill Project No: 18-196 Report No: I Sheet: I Test Date: 9/14/18 Technician: J.Jordan Required Compaction (%): 95 Test No. Test Location Elevation or Depth (ft.) Soil ID Moisture Dry Density Compaction Notes Below) I NW Comer of Pad 0-1 1951 8.5 100.4 100 2 NE Comer of Pad 0-1 1951 10.4 98.7 98 3 SW Corner of Pad 0-1 1951 10.9 101.3 100+ 4 SE Corner of Pad 0-1 1951 9.9 97.5 97 5 Center of Pad 0-1 1951 11.0 99.9 99 6 Center of Garage Pad 0-1 1951 11.0 100.6 100+ Moistime-Don-itv Rp.latinnQhin 1)ata- Soil ID dalimum Density OptimumI MoistureI Test Method Description LBR 1951 100.6 11.3 ASTMD1557 Gray Fine Sand N/A 4-1--UL. o) icstivimnous.- 2) "Retest result meets minimum compaction requirement. Density: ASTM D2937 3) Density in pounds per cubic foot (pcf). Moisture: ASTM D4944 4) Depth of test referenced from top of building pad. 4'Ir - #nIBLUE MARLIN ENGINEERING MODIFIED PROCTOR TEST TESTED FOR: Linton Enterprises Inc PROJECT: 819 Palmetto Avenue TEST METHOD: ASTM D1 557, Method A PROJECT NO: J18-196 DATE TESTED: September 4, 2018 SAMPLE NO: 1951 SAMPLE LOCATION: Subgrade SOIL DESCRIPTION: Gray Fine Sand 103 102 101 C4 100 F- tu 99 z 98 97 96 95 4- 7.0 8.0 9.0 4 10.0 11.0 12.0 13.0 MOISTURE CONTENT Maximum Dry Unit Weight (pcf): 100.6 Optimum Moisture Content (%): 11.3 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive,, Performancer or ERI Method, CoMr pliance 2017 Florida Building Code, Energy Conservation, 6ftEdition urisdiction: Permit #: Job 106=011on Builder Community: Lot: NA Address: 819 S PALMETTO AVE City: SANFORD State: FL Zip: 32771 Air Leakage Tesl R68'Ulft Passing results must meet either the Performance, PrescliPlive, or ERI Method PRESCRIPT11W 1111ETI,110D-T 6 building or dWelling unit shall be tested a I nd verified as having an air leakage rati of,not exceeding. T air I changes per hour atjwptessuro of 0.2-inch w.9,,(50 Pascals)in Climate Zones I and 2. PERFORMMCk or EM" Vil 110b*fie'bUlldlng or dwellin 1 0 unit shalf be tested. and verified as he I ving an I air leakage ra te of riot exceeding the selected ACH(50j vakie,.a's-shown on Form R405-2017 (Performance) o,r'R406-201 T (ERI), section labeled as infiltration, sub-sedtion AGH50. AC14(15QI spedfied on Fbrm R405-20 1 17- Enemy Calc (PeAlormawe) or-R 1 40 6-2017 (E RI) 7 1055 x- 60 20730 3.05 Method for calculatinq building volume: CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans F71 PASS G Code software calculatedV\ When ACH(50) is less I than 3, Mechanical Ventilation installation 0 Field measured and calculated L must be verified bybuilding department. 7 R4 02.4.1.2 Testin at a pressure of 6.2 inch w.g. (50 Pascals) g. Testing shall be conducted in accordzince with ANSI/RESNET/ICC 380 and reportedI Testing shall be conducted by either individuals,as defined in Section 553-.993(5) or (7), Florida Statues'.or individuals licensed as set forth in Section 489.105(3)(% (g), or (i) or an approved, third party. A writte I n report of the results of the test shall be signed by the party. conducting the test and provided to thecode,official. Te I sting shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not seated, beyond the intended weatherstripping or other infiltration, control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue. dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior -doors, If installed at the time of the test, shall be open. 4. Exterior doom for continuous ventilation systems and heat I recovery ventilators shall be closed and seated. 5. He'atin6and cooling systems, ifinstalled at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of -the test, shall be fully open. Tesfing- Company Company Name: 4 C-a c S V-' 0 :L C-- Phone: I hereby verify. that the above Ar Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance I method selected above. il- Date of Test: Signature of Tester-11 1."X. U1\ 10L 01 11X C Printed Name of Tester: l\,ry6 License/Ceftification Issuing Authority: 5/1/2010 10:53:1 7AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FIaRes2017 FBC 6th Edition (2017) Compliant Software Page I of I CITY OF 1,.i'"ORDA"TL BUILDING DIVISION PERMIT APPLICATION Application No: 18-2491 Documented Construction Value: $ 8,850-00 Job Address: 819 S Palmetto Ave, Sandford, Fl 32771 Parcel ID: Historic District: Yes [I NoFx1 Residential F] CommerciaIF] Type of Work: NewEl AdditionEl Alteration El RepairEl DemoEl Change of UseEl MoveEl Description of Work: 1 Fiberglass flexible clucting system, Aluminum adjustable grills, 1 3 1/2 TON 15 SEER York heat pump,_ 1 Digital thermostat Plan Review Contact Person: Phone: Fax: Name Street: City, State Zip: Name P&D Air, Inc. Street: 1115 S Crystal Lake Dr Orlando, FL 32806 City, State Zip: Name: Street: City, St, Zip: Bonding Company: Address: Title: Email: 24-A'kktMC'('-) Wd. offM Property Owner Informatio n U Phone: Resident of property?: Contractor Information Phone: 407-485-9300 Fax: 407-641-8774 CAC013021 State License No.: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITHYOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Ap plication is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. '( 5 FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6" Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that maybe found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Name Qm-a -W 11-19-18A, Signature of Contractor/Agent Date Donald Willis Print Contracto Signature of Notary -State Contractor/Agent is x "T0906; Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY 11-19-18 Date I WMe A fts COMMISSON #-M7& r 17 fXF48,ES! 0** 20, 9 WWWAARONvKnown Nollm-%? Permits Required: Building D Electrical El Mechanical [I Plumbing F1 Gas El Roof El Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes D NoF] # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes []No E] WASTE WATER: BUILDING: FIRE INSPECTIONS CITY OF SANFORD 407.562.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Application Number . . . . . 18-00002491 Date 11/19/18 Application pin number . . . 684959 Revision number . . . . . . . 1 Property Address . . . . . . 819 PALMETTO AVE Parcel Number: 25.19.30.5AG-1001-0090 Application type description NEW SINGLE FAMILY HOME - DETACHED Subdivision Name . . . . . . TWN OF SANFORD (TRAFFORDS KAP) Property Zoning . . . . . . . SINGLE FAMILY Application valuation . . . . 401074 Application desc new sfr/noc and contractor Owner Contractor DAVID & MARILYN PARKET P & D AIR INC 1810 BEACON 1115 S CRYSTAL LAKE DR SANFORD FL 32771 ORLANDO FL 32806 4 07) 3 12 - 62 17 (407) 285-4433 Structure Information 000 000 ---------------------- Construction Type . . . . . vB Occupancy Type . . . . . . RESIDENTIAL USE GROUP Flood zone . . . . . . . . NONE Other struct info . . . . . ELEC - # AMPS 200.00 PLUMBING FIXTURES 17.00 NUMBER OF STORIES 1.00 SQUARE FOOTAGE 3995.00 Permit . . . . . . MECHANICAL - NEW RESIDENTIAL Additional desc . . Phone Access Code 1088442 Permit pin number 1088442 Permit Fee . . . . 110.00 Issue Date . . . . 11/19/18 valuation . . . . 8850 Expiration Date . . 5/18/19 Qty Unit Charge Per Extension BASE FEE 110.00 Special Notes and Comments All projects within the City shall use WastePro for debris removal. Please contact WastePro at 407.774.0800. Normal hours for inspections are from 7:30 through 4:30 Monday through Thursday. Please be aware you must contact the Building Official to schedule a Friday or after hours inspection. This is required since not every inspector is licensed to do every type inspection. Communication is the key, so please contact the Building Official if you have any questions at 407.688.5058 or at dave.aldrich@sanfordfl.gov Existing house was demo. No utility impact fees required. old home had water and sewer. Other Fees . . . . . . . . . 01-APPLCTN FEE -ELECTRIC 50.00 01-APPLCTN FEE -BUILDING 25.00 01-APPLCTN FEE -MECHANIC 25.00 01-APPLCTN FEE -PLUMBING 25.00 01-BLDG PLAN REVIEW 1428.00 FAILURE TO COMPLY WITH MECHANIC'S LEIN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS. NOTE: ALL FEES MUST BE PAID PRIOR TO C.O. BEING ISSUED. NOTE: PLEASE BE ADVISED ALL PERMITS MUST BE INSPECTED. PEST, CONTROL INC 1-800-929-2847 Certificate of Compliance for Termite Protection as required by Florida Building Code (FBC) 1816.1.7) Treatment Address or Lot/Block/Unit of Treatment ZrLiquid Soil Barrier LjWood Treatment Lj Baiting System Lj Other Method of Termite Prevention Treatment) Legal Description: South half of Lot 9 and all of Lot 10, Block 10, Tier 1, Town of Sanford, according to the Plat thereof, as recorded in Plot Book 1, page 59, of the Public Records of Seminole County, Florida. A 8 B R E V I A T 1 0 N P.R.M. PERMANENT REFERENCE MONUMENT C.M. CONCRETE MONUMENT EL. ELEVATION CONC. CONCRETE P.O.C. POINT OF COMMENCEMENT P. B. PLAT BOOK A/C AIR CONDITIONER C.L.F. CHAIN LINK FENCE P.C. POINT OF CURVATURE Pg. PAGE TYP. TYPICAL W.F. WOOD FENCE P.R.C. POINT OF REVERSE CURVATURE N.R. NON —RADIAL U. E. UTILITY EASEMEN . T C & G CURB & GUTTER P.C.C. POINT OF COMPOUND CURVATURE RAID. RADIAL D. E. DRAINAGE EASEMENT CATV CABLE TELEVISION RISER P.T. POINT OF TANGENCY R. RADIUS F. F. FINISHED FLOOR TELE TELEPHONE RISER P.I. POINT OF INTERSECT10N L. ARC LENGTH B.S. BUILDING SETBACK TRANS TRANSFORMER PAD P. C' P. PERMANENT CONTROL POINT ln DELTA C. B. S. CONCRETE BLOCK STRUCTURE L.P. LIGHT POLE P.O.L.. POINT ON LINE R. P. RADIUS POINT P) PLAT P.P. POWER POLE CHORD BEARING R/W RIGHT—OF—WAY R MEASURED EM ELECTRIC METER T.B. TANGENT BEARING CENTER LINE C) CALCULATED R/W RIGHT OF WAY Survey Notes: 1. "NOT VALID WITHOUT THE. SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER". 2. BEARINGS SHOWN HEREON ARE RELATIVE TO THE EAST RIGHT—OF—WAY LINE OF PALMETTO AVENUE AS BEING S 00'14'35" E AS SHOWN BEING ASSUMED. 3. THE "LEGAL DESCRIPTION" HEREON PER THE PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA., 4. THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT OR OPINION OF TITLE. NO INSTRUMENTS OF RECORD REFLECTING EASEMENTS, RIGHTS —OF —WAY, AND/OR OWNERSHIP WERE FURNISHED TO THIS SURVEYOR EXCEPT AS NOTED. 5. ALL BEARINGS AND DISTANCES SHOWN HEREON ARE PER THE DESCRIPTION AND ARE CORRECT AND, IN AGREEMENT WITH THE FOUND AND SET MONUMENTS AS MEASURED IN THE FIELD UNLESS OTHERWISE NOTED. 6. ACCORDING TO THE NATIONAL FLOOD INSURANCE PROGRAM, FLOOD INSURANCE RATE MAP (FIRM) COMMUNITY PANEL NO. 12117CO07OF EFFECTIVE DATE: SEPTEMBER 28. 2007 THIS PROPERTY LIES IN ZONE :L LYING OUTSIDE THE FLOOD ZONE. 7. NO UNDERGROUND UTILITIES, FOUNDATIONS OR IMPROVEMENTS, IF ANY, HAVE BEEN LOCATED EXCEPT AS SHOWN. W.M. WATER METER F H. FIRE HYDRANT N & D NAIL AND DISC B.M. BENCH MARK PVMT. PAVEMENT F.B. FIELD BOOK M.H. MANHOLE A) ACTUAL I.D. IDENTIFICAT10N FND FOUND EOP EDGE OF PAVEMENT Certified Correct To: David E. Parker & Marilyn J. Parker Surveyoils Certification: 8. THIS BOUNDARY SURVEY MEETS OR EXCEEDS THE HORIZONTAL CONTROL I hereby certify that the attached "Boundary Survey" of theACCURACYOF1/7500 BEING A SUBURBAN SURVEY. hereon— described property is true and correct to the best of my knowledge, information and belief as done under my,direction in the9. ELEVATIONS SHOWN HEREON ARE BASED ON THE NORTH AMERICAN VERMAL DATUM OF 1988 field on, May 10, 2019. 1 further certify that this, "Boundary Survey" AND SAIDEUEVAnONS ARE BASED ON BENCHMARKS SUPPLIED BY THE SEMINOLE COUNTY SURVEY meets the Standards of P tice' 'as' nith in chapter 5J-17 ofDEPARTMENTSFOLLOWS: , roc the Florida Administrative Code MA RKa.) MARK # 140 TOP OF C.M. NTH BRASS DISC. ELEV. = 23.906 b MA RKb.) MARK # 142 TOP OF C.M. WITH BRASS DISC. ELEV. = 14.644 D.t.]05/10/19 Project N 0_ 542ProjectNo. 542—DMP-001 NOT VAUD WHOUT SYEET 2 W. C. EIlidt+,--P.t.M. . Professional Surveyor and Mapper filCwgfile: 542—DMP-001Dkw5V42Dg" Flor I ida Registration No. 5599 DRAWN: WCE Boundary Survey KLE SUrVeylng SHEET A 0PPROVED: WCE David E. Parker & Marilyn J. Parker 41 'Mapping. Inc., DATE: 05/10/19 81q Palmetto Avenue 153 Sir.;Topaz Lane Northon25, Township 19 South, Range 3o East Lake M ry, fL 32746SCALE: N/A City of Sanford, Seminole County, Florida (407) 402-2331 License Business # 7899 OF 2 war C) 00 ap r_ 0 0 ;0 C) 3: 0 0 > MM Z 4 t !' : 1. Al -A; j, FOUND CONCRETE MONUMENT IN WELL BOX NO I.D. CIL 8th STREET 66' PUBLIC RIGHT—OF—WAY PER PLAT) PAAQ RQAP 8' ADD17IONAL R/W PER PLAT TOUND 1" FOUND 5 8"' OU PIPE 14' IRON PI N 89*53'32" E 116.91' (M) IRON PIPI 0 1NOI D. 117' (P) NO I,D. 31_06'K 0) P. B. 'Y CAuGES59o Al I 1 7 0 4- CA 1 1. 1, — , -, rl, 7 4K CA FOUND 1/2" 01SET117 OMIRONROD & (P) IRON ROD (0)) SIGN CAP CAN NOT 59 C AP M READ 116.73 899 CAP N 39*5222" E (M) 1-, 7] 41 6. WOODWALK0.4' OFF A/C FENCE 6' WOOD 44.3' (0.5' OFF) SANITARY FENCE S' CLEAN LOT _ n00 2 - OUT CLEAN SEWER C_: -.,j (05 OFF) MIR II OUT MANHOLE ji-S 46 T_ F IRE, 12.5' c0n D P.R. 1 PAGES 59 23.98' i STORY C 2WOOD 1 — STORY ONCRARTF BLOCK Z' UTILITY CONCRETE BLOCK 1C. AGE F F I I POLE ca RESIDEN CE F. F. 30.7 11.7' 30. '7 4 F1 2.8'; W .. V x 0iA T 12.5' 5.9' G) RECLAIM. S -4- BLOCK —0, TE7R 1 — 5' WALKWAY X WATER METER 1 T,5W," 0F S4jVORC, Ui P B. 1 PAGES 59 1 CONCRETE 44 Ln A - WA_-_R ME1 R Q 101, 10.0, 1 3 .7' 0 IV CONCRETE 8D LANAI WALK IRRIGA_nON* SET CONTROL 30.3' 22. M IRON ROD VALVE P) 1 CAP LB 7899 N TEP 89*53'32" E 11 6 d6' M) PAVERVE DRIVEDRIVE 41' 1 N. 14' CONCRETE ADDITIONAL R/W PER PLATWALK0.4' OFF 8 J I -SE - T % C6CRETE IRON ROD Zj SIGN SIGN DRIVE & CAPi LB # 7899 CIL 9th STREET 66' PUBLIC RIGHT—OF—WAY PER PLAT) PAVED ROAD Pro*t No. 542-DMP-001 Dwg file: 542-DMP-001 DRAWN: WCE, B . oundary Survey KLE Surveying APPROVED: WCE David E. Parker & Marilyn J. Parker & Alapping, hic. DATE: 05/10/19 8ig Palmetto Avenue 153 Sir Topaz Lane North Section 25, Township ig South, Range 30 East Lake Mary, FL 32746 SCALE- 1" - 30' City of Sanford, Seminole County, Florida a (407) 402-2331 License Business # 7899 SHEET 2 OF 2 e Prevention DhAiwi, Buildino, & Fh WDAVITRE.lVlDEVTlA.L,RFR00FAF JtPM Rl iU4T RI-sjim Nw UL R u, - RoOF INSPECTION AFFIDAVIT NAILING, SHEATH.TNIG, DRY. -IN, FLASHING, AIND ALLFINALROOF CO-VERINGS BR19-000658 ADDRESS: 818 ESGAMBIA DRIVE. SANFORD, F1_0_R_l_0X_M7TF__ SCOTT MARONE AS A(Nl) GENERAL BUiLDING. Ry_'SkD.ENTfA_L. OR. ROOFING CONTRACTOR, ENGINEER, ARCI-UTF-_,Cl:. OF F.S. CHAPT[HR 468 BUILDING] NSP[-_'C,,TOR, 1. 1JERE'BY AFF110A. THAT AIJ. OF THE" JS,TR{.jEmNb AccuRATE A.\[D rl_IA,f ALL ROOFING I CONHIONENTS L6TED ONFITIESCOPEOF WORY ATTHE ABOVE.REFr.Rla NC.ED ADDRI',-SS.f.IAVI Bf'lN IINSTA I I -LED INI ACCORDANCE WT.11.1 TTIFIR PRODUCTAPRROVAUS AND AU AillICABL.E CODE FLORM N I -,lzl*lI y ETS A I LABUILDINGCOI)E, EXISTING BL71LDlN'Q. UNADDITiON U.- -_ -I'fi-[-.'.INSI:Al l ATI(IN:Ml' RF-,'QUlRE?vfE'N-TS FOR SECC)INDARY WATER BARR ND NAIL] NG OF _[Ta,. lwcw,DLCK, IN ACCORDA N-CF. WITH THE' UUR_R ICANE R.T:YROVIT MANt !AL REQUIREMENTS:(BASW Oi.F.S. CHAPn-,R 553.844i. UcE.N.- s i - -13-3-1 -1 -3 . ..... c.ol%,lPANfY./CQNTR A CrORt E 0EING LLCS__CM_ -0 CO,N'--I-RACI-C)fZ.,S-IGN,ATU.Itl:-;: DATEAPRIL 30.2019 M U S 1 S I Q NE, D P Y f, I.C. EMS E I 10 L D ER 0 R 0 %Vj\rJ__-.'PV A FINAL -Roou, IN'SPECTION N RF;()UIRFD: All, FMAVIT MUSTBE PROV"IDED Al THFJOR SITE ATTHE TIVIti Or- EACH PLAN-1,_,()F Tlll, ROOF SRONY'ING UN DETAIL ALL CONIPONEINTS (DEcku"K... UNDERLAVAlENT4 rLAS(IJN(; DRiP ERGE ATTACHMEN-11 ) i/rrwrill", lEwN.Irr'i\U'MBER,OR ADDRE.Ss CL&kRLYNIARKI-4) 01 1' 1 TFTFIIRFICI FOR,F.A(:J!l'INSPFcTIoN.t., 1'fa; Puuroc;R.-Pnsivtvs r uNCLUDL A RUCER OR NIFASURING DEVICETO CONFIRNLALJ,'N,AlL SPAC1N;GfANl' VAILURE TO.mut..OwALL RLQUIREM. I ENTS WILL RESULT IN ATAILED INSPECTION, A RE4NSPLCTJ.ON FEF. AS AVE LLAS IlEOUTRIINGA DESIGN PROFESSIONA L. (ARC 141T_L CT OR ENGIN EER)TO CERTI FY., BASEDON" VERSONAL NSP,r4,Cl-l 0,Nr.-i HE.I.N,.ST,A,.L-1,AT,ION-.OFAI.-,I,ROOFItN'GCOiMil'ONL'N'TS. cn c Sworn toand Subscribed before me ibis 30TH davof 0.'U'L..0 20 '0, hv. t — Al- ., - who is to me or has n Produced ft.vt)e oll identification) Sit atu e 4S Notary Pul—i St, c 0 Florioae_ tv, ame- of Nata6Tublic is identificafion. P- y CC, ',AISS;ON ff -897829 A.ugust 30. 201t,4 RECORD COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: P AND D AIR PARKER Builder Name: Street: 819 S PALMETTO AVE Permit Office: BUIL City, State, Zip: SANFORD, FL, 32771 Permit Number: 1 8 2 4 9Owner: DAVID AND MARILYN PARKER Jurisdiction: 94 Design Locatio n: FL, Sanford County:: Seminole (Florida Climate Zone 2 1 . New construction or existing New (From Plans) 9. Wall Types (1930.0 sqft.) Insulation 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.2 1930.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2073.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=30.0 2073.00 ft2 6. Conditioned floor area above grade (ft2) 2073 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(359.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 414.6 a. U-Factor: Dbl, U=0.35 359.33 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 30.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 30.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 5.976 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Natural Gas Tankless Cap: 1 gallons 8. Floor Types (2073.0 sqft.) Insulation Area EF: 0.850 a. Slab -On -Grade Edge Insulation R=0.0 2073.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.173 Total Proposed Modified Loads: 58.61 PASSTotalBaselineLoads: 64.85 I hereby certify that the plans and specifications covered by Review of the plans and E S;7r this calculation are in compliance with the Florida Energy specifications covered by this E :-F' - Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Maggie Sims DATE: Before construction is completed this building will be inspected for compliance with Section 553.9082018.05.03 0816:08 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL - DATE: DATE: t -_ - 19-- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). WSTORIC PERMIT Al we* must be done in strict accordam With &e Appovik! Certificate of Appropdaterms EkdIding does not approve any work outsi& dds geW Pennit Applicant is soley responsible for complimce 5/3/2018 8:14 AM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R4b5-2017 PROJECT Title: Building Type: Owner Name: of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: P AND D AIR PARKER User DAVID AND MARILYN PARK 1 Single-family New (From Plans) CODE COMPLIANCE 405-2017 Bedrooms: 3 Conditioned Area: 2073 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 819 S PALMETTO AVE Seminole SANFORD, FL, 32771 CLIMATE V Design Location TMY Site Design Temp 97.5% 2.5% Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Sanford FL—ORLANDO—SANFOR 39 93 70 75 677 44 Medium BLOCKS Number Name Area Volume 1 Blockl 2073 20730 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated I Main 2073 20730 Yes 4 3 1 Yes Yes Yes FLOORS y# Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 190 ft 0 2073 ft2 0 0 1 ROOF Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or shed Metal 2318 ft2 520 ft2 Light 0.6 No 0.9 No 30 26.6 ATTIC V# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2073 ft2 N N CEILING V# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 0 Blown 2073 ft2 0.11 Wood 513/2018 8:14 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R465-2017 WALLS y # nmt Adjacent To INA1 TWpe Space avitytall1p Width Ft In Height Et In Area Sheathing Framing Solar Below R-Vahie EraCtmon AhSnr Grade% 1 S Exterior Concrete Block - Int Insul Main 4.1999 18 2 10 181.7 ft2 0 0.400000 0 2 S Exterior Concrete Block - Int Insul Main 4.1999 18 8 10 186.7 ft2 0 0.400000 0 3 E Exterior Concrete Block - Int Insul Main 4.1999 15 6 10 155.0 ft2 0 0.400000 0 4 S Exterior Concrete Block - Int Insul Main 4.1999 11 8 10 116.7 ft2 0 0.400000 0 5 E Exterior Concrete Block - Int Insul Main 4.1999 32 6 10 325.0 ft2 0 0.400000 0 6 N Exterior Concrete Block - Int Insul Main 4.1999 44 4 10 443.3 ft2 0 0.400000 0 7 W Exterior Concrete Block - Int Insul Main 4.1999 17 8 10 176.7 ft2 0 0.400000 0 8 N Exterior Concrete Block - Int Insul Main 4.1999 4 2 10 41.7 ft2 0 0.400000 0 9 W Exterior Concrete Block - Int Insul Main 4.1999 30 4 10 303.3 ft2 0 0.400000 0 DOORS Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Main None 4 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.35 0.25 N 18.0 ft2 1 ft4 in 4 ft 0 in Drapes/blinds Exterior 5 2 S 1 Vinyl Low-E Double Yes 0.35 0.25 N 18.0 ft2 1 ft4in 8ft0in Drapes/blinds Exterior 5 3 S 2 Vinyl Low-E Double Yes 0.35 0.25 N 10.0 ft2 10 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 4 S 2 Vinyl Low-E Double Yes 0.35 0.25 N 42.7 ft2 10 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 5 S 2 Vinyl Low-E Double Yes 0.35 0.25 N 18.0 ft2 10 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 6 E 3 Vinyl Low-E Double Yes 0.35 0.25 N 42.7 ft2 11 ft 8 in 0 ft 6 in Drapes/blinds Exterior 5 7 S 4 Vinyl Low-E Double Yes 0.35 0.25 N 42.7 ft2 6 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 8 E 5 Vinyl Low-E Double Yes 0.35 0.25 N 36.0 ft2 1 ft 4 in 0 ft 6 in Drapes/blinds Exterior 5 9 E 5 Vinyl Low-E Double Yes 0.35 0.25 N 8.7 ft2 1 ft 4 in 0 ft 6 in Drapes/blinds Exterior 5 10 N 6 Vinyl Low-E Double Yes 0.35 0.25 N 8.7 ft2 1 ft 4 in 3 ft 0 in Drapes/blinds Exterior 5 11 N 6 Vinyl Low-E Double Yes 0.35 0.25 N 12.0 ft2 1 ft 4 in 8ft0in Drapes/blinds Exterior 5 12 N 6 Vinyl Low-E Double Yes 0.35 0.25 N 18.0 ft2 1 ft 4 in 10 ft 0 in Drapes/blinds Exterior 5 13 W 7 Vinyl Low-E Double Yes 0.35 0.25 N 36.0 ft2 1 ft 4 in 0 ft 6 in Drapes/blinds Exterior 5 14 W 9 Vinyl Low-E Double Yes 0.35 0.25 N 48.0 ft2 10 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 INFILTRATION Scope Method SLA CFM 510 ELA EqLA ACH ACH 50 1 Wholehouse L Proposed ACH(50) .000445 2418.5 132.77 249.7 3247 7 5/312018 8:14 AM EnergyGaugeO USA - FIaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R465-2017 HEATING SYSTEM System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 30 kBtu/hr 1 sys#1 COOLING SYSTEM V7--# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts Central Unit/ None SEER: 15 30 kBtu/hr 1000 cfm 0.7 1 sys#1 HOT WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas, Tankless Exterior 0.85 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS V # Supply Location R-Value Area Return -- Air Location Area Leakage Type Handier CFM 25 CFM25 TOT OUT QN RLF HVAC # Heat Cool I Attic 6 414.6 ft Attic 103.65 Default Leakage Attic Default) (Default) 1 1 TEMPERATURES Prograrnable Thermostat: Y Cooling Jan Feb Mar Heating Jan Feb Mar Venting H Jan H Feb HX Mar Ceiling Fans: Apr pr MaMay Jul ugg y rl Jun ri AuAJunJulA Apr May Jun ri Jul Aug SeepXjS Sep Oct Nov Oct Nov Oct X Nov Dec Dec Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) Cooling (WEH) Heating (WD) Heating (WEH) AM 78 PM 80 AM 78 PM 78 AM 66 PM 68 AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 68 68 66 66 68 68 68 68 68 68 78 80 78 78 78 78 78 78 68 68 68 68 68 68 68 68 80 80 78 78 78 78 78 78 68 68 68 66 68 68 68 66 80 78 78 78 68 66 68 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Wafts HRV Heating System Run Time Cooling System None 0 0 0 1 - Electric Heat Pump 0% 1 7 Central Unit 5/3/2018 8:14 AM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 I FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the EnergyPerformance Index, the more efficient the home. 819 S PALMETTO AVE, SANFORD, FL, 32771 1 . New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.2 1930.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=30.0 2073.00 ft2 6. Conditioned floor area (ft2) 2073 b. N/A R= ft2 7. Windows— Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.35 359.33 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 414.6 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 30.0 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 30.0 HSPF:8.50 Area Weighted Average Overhang Depth: 5.976 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 2073.00 ft2 a. Natural Gas EF: 0.85 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/Fl- Zip: Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/3/2018 8:14 AM EnergyGauge@ USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 819 S PALMETTO AVE Permit Number: SANFORD, FL, 32771 MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPIL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4. 1. 1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(D, (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/l.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 5/3/2018 8:14 AM EnergyGauge@ USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 Controls. SECTION R403 SYSTEMS R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or 7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handier enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105*F (41 oC) or below 55oF (1 3oC) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 5/3/2018 8:14 AM EnergyGaugeS USA - FlaRes2017 - FBC 6th Edition (2017) Complian Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 % inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 1 00'F to 140'F (38*C to 60'C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the followring criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. 1 . The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-1 1 and the ceiling shall be insulated to a minimum of R-1 9, space permitting, or R-1 0 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302. 1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM) MINIMUM EFFICACY a CFMfWATT) AIRFLOW RATE MAXIMU CFM) Range hoods Any 2.8 cfm/waft Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/waft 90 Bathroom, utility room 90 2.8 cfm/waft Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 5/3/2018 8:14 AM EnergyGauge(D USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1 Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.11.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1 . A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the [ECC--Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50'F (1 O'C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F (4.8'C). R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 5/3/2018 8:14 AM EnergyGaugeO USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (MandatorYI)he energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 5/3/2018 8:14 AM EnergyGaugeO USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: P AND D AIR PARKER Builder Name: Street: 819 S PALMETTO AVE Permit Office: City, State, Zip: SANFORD, FL, 32771 Permit Number: Owner: DAVID AND MARILYN PARKER Jurisdiction: Design Location: FL, Sanford COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overiapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Pxtpnd behind o'pong and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire so nkler cover plates and walls or ceilmnas. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 5/3/2018 8:14 AM EnergyGaugeG USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method Project Name: P AND D AIR PARKER Builder Name: Street: 819 S PALMETTO AVE Permit Office: City, State, Zip: SANFORD, FL, 32771 Permit Number: Design Location: FL, Sanford Jurisdiction: Cond. Floor Area:: 2073 sq.ft. Cond. Volume: 20730 cu ft. Envelope Leakage Test Results Regression Data: C: n: Single or Multi Point Test Data R: HOUSE PRESSURE FLOW: 1 Pa cfm 2 Pa cfm 3 Pa cfm 4 Pa cfm 5 Pa cfm 6 Pa cfm Leakage Characteristics Required ACH(50) from FORM R405-2017 -. Tested ACH(50) *: Tested leakage must be less than or equal to the required ACH(50) shown on Form R405-2017 for this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3. Interior doors, if installed at the time of the test, shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. SIGNATURE: PRINTED NAME: DATE: Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f)l, (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the third party conducting the test and provided to the code official. BUILDING OFFICIAL: DATE: 5/3/2018 8:15 AM EnergyGaugeO USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 wrightsoft* Building Analysis Entire House P AND D AIR Job: PARKER Date: May 02, 2018 By: ENERGYCALCS.NET INC ENERGYCALCS.NET INC 267 DELEON RD, DEBARY, FIL 32713 Phone: 386-775-0908 Email: MAGGIE@ENERGYCALCS-NET License: RESNET#4557900 For: DAVID AND MARILYN PARKER 819 S PALMETTO AVE, SANFORD, FL 32771 5 Location: Indoor: Heating Cooling Orlando Sanford AP, FL, US Indoor temperature (OF) 70 75 Elevation: 56 ft Design TD (OF) 28 18 Latitude: 29'N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 22.9 38.1 Dry bulb (OF) 42 93 Infiltration: Dailyrange (OF) - 17 M Method Simplified V\Iet bulb (OF) - 75 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh of load Walls 4.0 6026 25.4 Glazing 9.7 3661 15.4 Doors 10.8 227 1.0 Ceilings 1.2 2409 10.2 Floors 3.0 6276 26.4 Infiltration 1.2 2305 9.7 Ducts 2827 11.9 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 23730 100.0 Component Btu h/ft2 Btuh of load Walls 2.8 4286 18.2 Glazing 12.9 4857 20.7 Doors 12.1 253 1.1 Ceilings 1.0 1992 8.5 Floors 0 0 0 Infiltration 0.4 749 3.2 Ducts 1941 8.3 Ventilation 0 0 Internal gains 9420 40.1 Blower 0 0 Adjustments 0 1 Total 1 1 234981 100.01 Latent Cooling Load = 2762 Btuh Overal I U-va I ue = 0.2 36 Btuh/ft2-'F Data entries checked. NEW G.-dr RE RM., wrightsoft- 2018-May-03 07:55:04 Right -Su ite(M U niv ersal 2018 18.0.16 RSUl 9553 Page 1 C:\User's\edwol\Downloads\P AND D AIR PARKER.rup Calc = MJ8 Front Door faces: W wrightsofte Project Summary Entire House P AND D AIR Job: PARKER Date: May 02, 2018 By: ENERGYCALCS.NET INC ENERGYCALCS.NET INC 267 DELEON RD, DEBARY, FL 32713 Phone: 386-775-0908 Email: MAGGI E@ENERGYCALCS. NET License: RESNET#4557900 For: DAVID AND MARILYN PARKER 819 S PALMETTO AVE, SANFORD, FL 32771 Notes: Weather: Orlando Sanford AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 93 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 38 gr/lb Heating Summary Structure 20904 Btuh Ducts 2827 Btuh Central vent (0 cfm). 0 Btuh qone) Humidification 0 Btuh Pipigg 0 Btuh Equipment load 23730 Btuh Infiltration Method Construction quality Fireplaces Simplified Semi -tight 0 Heatin Cool Area (ft 206? 20167 Volume (ft') 20670 20670 Air changes/hour 0.22 0.11 Equiv. AVF (cfm) 76 38 Heating Equipment Summary Make GENERIC Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 0 OF 8.5 HSPF 30000 Btuh@47-F 27 OF 1000 Cfrn 0.042 cfm/Btuh 0.50 in H20 Sensible Cooling Equipment Load Sizing Structure 21557 Btuh Ducts 1941 Btuh Central vent (0 cfm) 0 Btuh none) Blower 0 Btuh Use manufacturers data y Rate/swin multi lier Equipmen?sensi le load 1.00 23498 Btuh Latent Cooling Equipment Load Sizing Structure 1780 Btuh Ducts 982 Btuh Central vent (0 cfm) 0 Btuh pone) Equipment latent load 2762 Btuh Equipment Total Load (Sen+Lat) 26260 Btuh Req. total capacity at 0.91 SHR 2.2 ton Cooling Equipment Summary Make GENERIC Trade Cond Coil AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 15 SEER 27300 Btuh 2700 Btuh 30000 Btuh 1000 cfm 0.043 cfm/Btuh 0.50 in H20 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Az wvr1gtms4 tfr- 2018-May-03 07:55:04 Right-SuiteD U niversal 2018 18.0.16 RSL11 9553 Page 14MC:\UserskedwoIkDownIoads\P AND D AIR PARKER.rup Calc = MJ8 Front Door faces: W Manual S Compliance Report Job: PARKER wrightsofto Date: May 02, 2018 Entire House By: ENERGYCALCS.NET INC P AND D AIR ENERGYCALCS.NET INC 267 DELEON RD, DEBARY, FL 32713 Phone: 386-775-0908 Email: MAGGIE@ENERGYCALCS. NET License: RESNET#4557900 For: DAVID AND MARILYN PARKER 819 S PALMETTO AVE, SANFORD, FL 32771 Design Conditions Outdoor design DB: For: DAVID AND MARILYN PARKER 819 S PALMETTO AVE, SANFORD, FL 32771 Design Conditions Outdoor design DB: 93.0'F Sensible gain: 23498 Btuh Entering coil DB: 75. 1'F Outdoor design WB: 75.10F Latent gain: 2762 Btuh Entering coil WB: 62.7F Indoor design DB: 75.00F Total gain: 26260 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: GENERIC Model: Actual airflow: 1000 cfm Sensible capacity: 27200 Btuh 1161/o of load Latent capacity: 2800 Btuh 101% of load Total capacity: 30000 Btuh 114% of load SHR: 91% VW-W Design Conditions Outdoor design DB: 42.3*F Heat loss: 23730 Btuh Indoor design DB: 70.0'F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: GENERIC Model: Actual airflow: 1000 cfm Output capacity: 30000 Btuh 126% of load Supplemental heat required: 0 Btuh Meets all requirements of ACCA Manual S. Entering coil DB: 69.9'F Capacity balance: 0 'F Economic balance: 0 'F Fk wrightsoft- 2018-May-03 07:55:04 Rig ht-Su ite@ U niversal 2018 18.0.16 RSU 19553 Page 1 C:\User's"\e—d,wol—\Dow—nioa'ds—\P AND D AIR PARKER.rup Calc = MJ8 Front Door faces: W RECORD CO Y- __ - DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00—THERMAL INSULATION HZST0R1CPERKff All work must be done in strict accordance with the Approved Certificate of Approp6ateness Building does not approve any work outside this scope pernut Applicant is soley vesponsible for contphancc REPORT HOLDER: SES FOAM 4008 LOUETTA ROAD, #538 SPRING, TEXAS 77388-4405 EVALUATION SUBJECT: SANFonD 18e-4 '9 1 SUCRASEAL TM 0.5 AND SES FOAM 0.5 LB SPRAY: SPRAY -APPLIED POLYURETHANE FOAM PLASTIC INSULATION 1CC 1CC C PIVIG c LISTED Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council WSSPQ Award in Excellence" WERNATIOML A Subsidiary of cq0Ec0uNR1r SCC A=.dhd C"rICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by 1CC Evaluation Service, LLC, express or implied, as ISM EIC 1706 5 GO to anyfinding or other matter in this report, or as to any product covered by the report. RrodmL CcrtiRmtlon E t'lum Copyright Q 2017 ICC Evaluation Service, LLC. All rights reserved. IMES Evaluation Report ESR-3375 Reissued August 2016 Revised October 16, 2017 This report is subject to renewal August 2018. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code CouncilO DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: SESFOAM 4008 LOUETTA ROAD, #538 SPRING, TEXAS 77388-4405 713) 239-0252 www.sesfoam.com EVALUATION SUBJECT: SUCRASEAL TM 0.5 AND SES FOAM 0.5 LB SPRAY: SPRAY -APPLIED POLYURETHANE FOAM PLASTIC INSULATION 1.0 EVALUATION SCOPE 1.1 Compliance with the following codes: N 2012 and 2009 International Building Codee (I BC) 0 2012 and 2009 International Residential Codee (IRC) E 2012 and 2009 International Energy Conservation Code' (IECC) E Other Codes (see Section 8.0) Properties evaluated: Surface -burning characteristics Physical properties Thermal resistance (R-values) Air permeability Exterior walls in Types I -IV construction 1.2 Evaluation to the following green standard: N 2008 ICC 700 National Green Building Standard TM (ICC 700-2008) Attributes verified: N See Section 3.1 2.0 USES SucraseaITM 0.5 spray polyurethane foam plastic insulation is used as a nonstructural thermal insulating material in buildings of Type 1, 11, 111, IV and V (IBC) construction, and in dwellings built under the IRC. The insulation is for use in wall cavities and floor/ceiling assemblies, and in attics and crawl spaces when installed as described in Section 4.4. Under the IRC, the insulation may be used as air - impermeable insulation when installed as described in Section 3.4. SES Foam 0.5 lb Spray is identical to SucraseaITM 0.5. Wherever SucraseaITM 0.5 is mentioned, the same property applies to SES Foam 0.5 lb Spray. 3.0 DESCRIPTION 3.1 General: Sucraseall-m 0.5 spray foam insulation is a two - component, open cell, one -to -one -by -volume spray - applied polyurethane foam system with a nominal density of 0.5 pcf (8.0 kg/M3) . The insulation's liquid components are supplied in nominally 55-gallon drums, labeled as "A" component or "B" component. The insulation components have a shelf life of six months when stored in unopened containers at temperatures between 70*F (21'C) and 90'F 32-C). The attributes of the insulation have been verified as conforming to the provisions of ICC 700-2008 Section 703.2.1.1.1(c) as an air impermeable insulation. Note that decisions on compliance for those areas rest with the user of this report. The user is advised of the project -specific provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this report. These codes or standards often provide supplemental information as guidance. 3.2 Surface -burning Characteristics: At a maximum thickness of 4 inches (102 mm) and a nominal density of 0.5 pcf, the insulation has a flame - spread index of 25 or less and a smoke -developed index of 450 or less when tested in accordance with ASTM E84. Thicknesses for wall cavities and ceiling cavities are not limited when the insulation is covered with a minimum 1/ 2-inch-thick (12.7 mm) gypsum board installed in accordance with the applicable code. 3.3 Thermal Resistance (R-values): The insulation has thermal resistance (R-values) at a mean temperature of 75'F (24*C) as shown in Table 1. 3.4 Air Permeability: The insulation, at a minimum thickness of 3 inches 76 mm), is considered air -impermeable in accordance with IRC Section R202, based on testing in accordance with ASTM E283. 3.5 DC 315 Coating: DC 315 Coating is manufactured by International Fireproof Technology, Inc. / Paint to Protect Inc. (ESR-3702 , and is a water -based intumescent coating supplied in 5-gallon ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement ofthe subject ofthe report or a recommendationfor its use. There is no warranty by ICC Evaluation Service, LLC, express or implied as to anyfinding or other matter in this report, or as to anyproduct covered by the report. Copyright@ 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of I I ESR-3375 I Most Widely Accepted and Trusted Page 2 of 11 19 Q pails and 55-gallon (208 Q drums and has a shelf life of six months when stored in a factory -sealed container at temperatures between 50'F (11 O'C) and 80*F (27'C). 3.6 FireShello FIOE: FireShell 0 F10E is manufactured by TPR 2 Corporation E5E-3997), and is a water -based coating supplied in 5-gallon (19 Q pails and 55-gallon (208L) drums and has a shelf life of one year when stored in a factory -sealed container at temperatures between 45'F (7.2'C) and 90'F 35-C). 4.0 INSTALLATION 4.1 General: SucraseaITM 0.5 spray insulation must be installed in accordance with the manufacturer's published installation instructions and this report. A copy of the manufacturer's published installation instructions must be available at all times on the jobsite during installation. 4.2 Application: The insulation is spray -applied at the jobsite using a volumetric positive displacement pump as identified in the SucrasealTM 0.5 spray application manual. The insulation components must be stored at temperatures between 70*F (21'C) and 90*F (32'C) for several days before application. The insulation must not be used in areas that have maximum in-service temperatures greater than 180*F 82'C). The insulation must not be used in electrical outlet or junction boxes or in contact with water (e.g., rain, condensation, ice, snow) or soil. The substrate must be free of moisture, frost or ice, loose scales, rust, oil, grease or other surface contaminants. The insulation can be installed in one pass to the maximum thickness. The spray -applied foam insulation must be protected from weather during and after installation. 4.3 Thermal Barrier: 4.3.1 Application with a Prescriptive Thermal Barrier: SucrasealTm 0.5 spray insulation must be separated from the interior of the building by an approved thermal barrier of 1/2-inch-thick (12.7 mm) gypsum wallboard or an equivalent 15-minute thermal barrier complying with, and installed in accordance with, IBC Section 2603.4 or IRC Section R316.4, as applicable, except when the installation is in accordance with Section 4.3.2. Within an attic or crawl space, installation must be in accordance with Section 4.4. 4.3.2 Application without a Prescriptive Thermal Barrier: The prescriptive 15-minute thermal barrier may be omitted when installation is in accordance with this section. The insulation and coating may be spray -applied to the interior facing of walls and the underside of roof sheathing or roof rafters, and in crawl spaces, and may be left exposed as an interior finish without a prescribed 15-minute thermal barrier or prescribed ignition barrier when the installation is in accordance with either Sections 4.3.2.1 or 4.3.2.2. 4.3.2.1 Application with DC 315 Coating: The thickness of the foam plastic applied to the underside of roof sheathing and to vertical wall surfaces must not exceed 111/2 inches (292 mm). The foam plastic must be covered on all surfaces with DC 315 Coating (ESR-3702) at a minimum thickness of 18.0 mils (0.47 mm) wet film thickness [12 mils (0.30 mm) dry film thickness] with a minimum application rate of 1.12 gal/100 ft2 . The coating must be applied over the Sucrasea[TM 0.5 insulation in accordance with the coating manufacturers published instructions and this report. Surfaces to be coated must be dry, clean and free of dirt, loose debris and other substances that could interfere with adhesion of the coating. The coating is applied in one or more coats with brush, roller or airless spray equipment. 4.3.2.2 Application with FireShello FIOE: The thickness of the foam plastic applied to the underside of roof sheathing and to vertical wall surfaces must not exceed 111/2 inches (292 mm). The foam plastic must be covered on all surfaces with FireShello F10E (ESR-3997 at a minimum thickness of 20.0 mils (0.51 mm) wet film thickness [14 mils (0.36 mm) dry film thickness] with a minimum application rate of 1.25 gal/100 ft2. The coating must be applied over the SucrasealTM 0.5 insulation in accordance with the coating manufacturer's published instructions and this report. Surfaces to be coated must be dry, clean and free of dirt, loose debris and other substances that could interfere with adhesion of the coating. The coating is applied in one or more coats with brush, roller or airless spray equipment. 4.4 Attics and Crawl Spaces: 4.4.1 Application with a Prescriptive Ignition Barrier: When SucraseaITM 0.5 spray is installed within attics and crawl spaces, where entry is made only for service of utilities, an ignition barrier must be installed in accordance with IBC Section 2603.4.1.6 or IRC Section R316.5.3 or R316,5.4, as applicable, except when the installation is in accordance with Section 4.4.2 or Section 4.4.3. The ignition barrier must be consistent with the requirements for the type of construction required by the applicable code, and must be installed in a manner so that the foam plastic insulation is not exposed. SucrasealT11 0.5 spray insulation at a minimum thickness of 3 inches (76 mm) may be installed in unvented attics in accordance with 2012 IRC Section R806.5 (2009 IRC Section R806.4), as applicable. 4.4.2 Application without a Prescriptive Ignition Barrier: Where the spray -applied insulation is installed in accordance with this section or Section 4.4.3, the following conditions apply: a) Entry to the affic or crawl space is to service utilities, and no storage is permitted. b) There are no interconnected attic or crawl space areas. c) Air in the attic or crawl space is not circulated to other parts of the building. d) Attic ventilation is provided when required by IBC Section 1203.2 or IRC Section R806, except when air -impermeable insulation is permitted in unvented attics in accordance with 2012 IRC Section R806.5 or 2009 IRC Section R806.4. Under -floor (crawl space) ventilation is provided when required by IBC Section 1203.3 or IRC Section R408.1, as applicable. e) Combustion air is provided in accordance with Intemational Mechanical Codee Section 701. In attics, the insulation may be spray -applied to the underside of roof sheathing or roof rafters, and/or vertical surfaces, and in crawl spaces the insulation may be spray - applied to the underside of floors and/or vertical surfaces as described in this section. The thickness of the foam plastic applied to the underside of the top of the space must not exceed 12 inches (305 mm). The thickness of the foam plastic applied to vertical surfaces must not exceed 11 1 /2 inches (292 mm). The foam plastic may be installed without a covering or coating. The insulation may be installed in unvented attics in accordance with 2012 IRC Section R806.5 (2009 IRC Section R806.4). The ignition barrier in accordance with IBC Section 2603.4.1.6 or IRC Section R316.5.3 may be omitted. ESR-3375 I Most Widely Accepted and Trusted Page 3 of I I 4.4.3 Use on Attic Floors: SucraseaITM 0.5 spray insulation may be installed exposed at a maximum thickness of 111/2 inches (292 mm) between joists in attic floors. The ignition barrier in accordance with IBC Section 2603.4.1.6 or IRC Section R316.5.3 may be omitted. The insulation must be separated from the interior of the building by an approved thermal barrier. 4.5 Exterior Walls of Type 1, 11, 111 and IV Construction: 4.5.1 General: When used on walls of Type 1, 11, 111 and IV exterior wall construction, the Sucrasea ITM 0.5 spray - applied foam insulation must comply with Section 2603.5 of the IBC and this section. The potential heat of SucraseaITM 0.5 spray -applied foam insulation is 466 BtU/ft2 (5.26 Mj/M2) per inch of thickness when tested in accordance with NFPA 259. 4.5.2 Specific Wall Assemblies: Wall assemblies must be as described in Table 2. 5.0 CONDITIONS OF USE The SucraseaITM 0.5 spray polyurethane foam plastic insulation described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The insulation must be installed in accordance with the manufacturer's published installation instructions, this evaluation report and the applicable code. If there are any conflicts between the manufacturer's published installation instructions and this report, this report governs. 5.2 The insulation must be separated from the interior of the building by an approved 15-minute thermal barrier, as described in Section 4.3.1, except when the installation is in accordance with Section 4.3.2. Installation in an attic or crawl space must be as described in Section 4.4. 5.3 The insulation must not exceed the thicknesses noted in Sections 3.2, 4.3, and 4.4. 5.4 The insulation must be protected from exposure to the weather during and after application. 5.5 The insulation must be applied by contractors certified by SES Foam. 5.6 Use of the insulation in areas where the probability of termite infestation is "very heavy" must be in accordance with 2012 IBC Section 2603.9 (2009 IBC Section 2603.8) or IRC Section R318.4, as applicable. 5.7 Jobsite certification and labeling of the insulation must comply with IRC Sections N1101.4 and N1101.4.1 and IECC Sections R303.1.1 and 303.1.1.1, as applicable. 5.8 When use is on exterior wall of buildings of Type 1, 11, III or IV construction, construction must be as described in Section 4.5 and Table 2. 5.9 A vapor retarder must be installed in accordance with the requirements of the applicable code. 5.10 SucrasealTM 0.5 spray polyurethane foam plastic insulation is produced in St. Louis, Missouri, under a quality -control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Spray -applied Foam Plastic Insulation AC377), dated April 2016, including reports of tests in accordance with Appendix X of AC377. 6.2 Reports of room corner fire -testing in accordance with NFPA 286. 6.3 Report of air permeance testing in accordance with ASTM E283. 6.4 Report of potential heat testing in accordance with NFPA 259. 6.5 Report of fire propagation testing in accordance with NFPA 285. 6.6 Engineering evaluation extending NFPA 285 testing to various exterior wall constructions. 7.0 IDENTIFICATION Components of the SucraseaITM 0.5 spray polyurethane foam plastic insulation are identified with the manufacturer's name (SES Foam) and address; the date of manufacture or the lot number; the product trade name SucrasealTM 0.5); the mixing instructions; the density; the flame -spread and smoke -developed indices; and the evaluation report number (ESR-3375). International Fireproof Technology, Inc. / Paint to Protect Inc., DC 315 Coating is labeled with the manufacturer's name and address; the product name; the date of manufacture, the shelf life or expiration date; the manufacturer's instructions for application and evaluation report number (ESR-3702 . TPR 2 Corporation Fireshell F10E coatings and Blazelok TBX coating is labeled with'the manufacturers name and address; the product name; the date of manufacture, the shelf life or expiration date; the manufacturer's instructions for application and evaluation report number (ESR-3097). 8.0 OTHER CODES In addition to the codes referenced in Section 1.0, the products in the report were evaluated for compliance with the requirements of the following codes: 13 2006 International Building Codee E3 2006 International Residential Code@ 2006 International Energy Conservation Code The products comply with the above mentioned codes as described in Sections 2.0 through 7.0 of this report, with revisions as noted below: 0 Application with and without a Prescriptive Thermal Barrier: See Section 4.3, except the approved thermal barrier must be installed in accordance with Section R314.4 of the 2006 1 RC. Application with a Prescriptive Ignition Barrier: See Section 4.4.1, except an ignition barrier must be installed in accordance with Section R314.5.3 or R314.5.4 of the 2006 1 RC. Application without a Prescriptive Ignition Barrier: See Section 4.4.2, except that combustion air is provided in accordance with Sections 701 and 703 of the 2006 IECC. 13 Protection against Termites: See Section 5.6, except use of the insulation in areas where the probability of termite infestation if "very heavy" must be in accordance with Section R320.5 of the 2006 IRC. 3 Jobsite Certification and Labeling: See Section 5.7, except jobsite certification and labeling must comply with Sections 102.1.1 and 102.1.1.1, as applicable, of the 2006 IECC. ESR-3375 I Most Widely Accepted and Trusted Page 4 of 11 TABLE 11—THERMAL RESISTANCE (R-VALUES' 2) THICKNESS (inches) R-VALUE ff-ilf-h/Btu) 4.0 2 7.6 3 11 3.5 13 4 15 5 19 6 22 7 26 8 30 9 33 10 37 11 41 12 44 For SI: 1 inch= 25.4 mm, 1*F.ft2.h/Btu = 0.176 110K.m2/W. R-values are calculated based on tested K values at 1- and 3.5-inch thicknesses. 2 R-values greater than 10 are rounded to the nearest whole number. TABLE 2—NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES WALL COMPONENT MATERIALS 1 —Concrete wall 2 — Concrete Masonry wall Base wall system — Use either 3 — 1 layer Of 5/8-inch thick Type X gypsum wallboard installed on the interior side of minimum 3--'/8 inch 1, 2, or 3 deep minimum 20 gauge thick steel studs spaced a maximum of 24-inch on center. Lateral bracing installed minimum every 4 ft. vertically or as required. Wall stud cavities shall be filled at each floor line with minimum 4 lb/ft3 mineral -fiber insulation friction fit between steel wall studs. Resilient Channel — For use with Base Wall System 3 above 1 — None 2 — Double leg "hat" shaped steel resilient channel installed perpendicular to the wall studs (interior side Use either 1 or 2 only) and spaced a maximum of 24-inches on center between steel studs and Type X gypsum wallboard. Entire perimeter of window opening to be framed with resilient channel. Perimeter Fire Barrier System Perimeter fire barrier system complying with Section 715.4 of the 2012 IBC shall be installed to fill the void between the edge of the concrete floor slab and the interior surface of the exterior wall assembly. Full wall stud cavity depth or less of SucraSeal"m 0.5 spray -applied foam plastic insulation applied using Wall Stud Cavity Insulation exterior gypsum sheathing as the substrate and covering the width of the cavity and the inside of the steel wall stud framing flange. Exterior sheathing — For Base Wall System 3 above 5/8-inch thick Type X exterior type gypsum sheathing complying with ASTM C1 177. 1 — Any non-combustible exterior wall covering material Exterior Wall Covering — Use 2 — Any non-combustible exterior wall covering system with a combustible WRB that has successfully been either 1, 2, or 3 tested in accordance with NFPA 285. see Note 1 below) 3 — Metal Composite Material (MCM) Mitsubishi Plastic Composites America, Inc., Alpolic/fir wall panels see ICC-ES ESR-2653) or Alcoa Architectural Products Reynobond FIR 6-mm panels (see ICC-ES ESR- 3435) where there is no exterior insulation in the cavity behind the panels. Flashing of vvii dow, door and As an option, flash around window, door and other exterior penetrations with limited amounts of maximum other exterior wall penetrations. 12-inch wide acrylic, asphalt or butyl -based flashing tape or liquid applied membrane material. For SI: 1 inch = 25.4 mm; 1 pcf = 16.0 kg/M3. Note 3: Exterior wall coverings shall be installed in accordance with the manufacturers installation requirements and must comply with the applicable provisions of 113C Chapter 14 and IRC Chapter 7. ICC-ES Evaluation Report ESR-3375 FBC Supplement Reissued August 2016 Revised October 2017 This report is subject to renewal August 2018. www.icc-es.org 1 (800) 423-6687 1 (562) 699-0543 A Subsidiary of the International Code Councile DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: SES FOAM 4008 LOUETTA ROAD, #538 SPRING, TEXAS 77388-4405 713) 239-0252 www.sesfoam.com EVALUATION SUBJECT: SUCRASEAL TM 0.5 AND SES FOAM 0.5 LB SPRAY: SPRAY -APPLIED POLYURETHANE FOAM PLASTIC INSULATION 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that SucraSeal 0.5 spray polyurethane foam plastic insulation, recognized in ICC-ES master evaluation report ESR-3375, has also been evaluated for compliance with the codes noted below. Applicable code editions: 13 2014 Florida Building Code —Building N 2014 Florida Building Code —Residential 2.0 CONCLUSIONS The SucraSeal 0.5 spray polyurethane foam plastic insulation (also known as SES Foam 0.5 lb Spray), described in Sections 2.0 through 7.0 of the master evaluation report ESR-3375, complies with the Florida Building Code —Building and the Florida Building Code —Residential, provided the design and installation are in accordance with the 2012 International Building Codeo (IBC) and 2012 International Residential Code (IRC) provisions noted in the master report under the following conditiom. Installation must meet the requirements of Sections 1403.8 and 2603.9 of the Florida Building Code —Building and Sections R318.7 and R318.8 of the Florida Building Code —Residential, as applicable. Use of Sucraseal 0.5/SES Foam 0.5 lb spray -applied polyurethane foam plastic insulation has also been found to be in compliance with the High -Velocity Hurricane Zone provisions of the Florida Building Code —Building and the Florida Building Code —Residential. For products falling under Florida Rule 9N-3, verification that the report holders quality -assurance program is audited by a quality -assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued August 2016 and revised October 16, 2017. ICC-ES I., valuation Reports are not to be construedas representing aesthetics or any other attributes not specifically addressed, nor are they lobe construed as an endorsement ofthe subject ofthe report or a recommendationfor its use. There is no warranty by [CC Evaluation Service, LLC, express or implied, as IN to anyfinding or other matter in this report, or as to any product covered by the report. Copyright@ 2017 ICC Evaluation Service, LLC. All rights reserved. Page 5of11 ICC-ES Evaluation Report ESR-3375 Seal and Insulate with ENERGY STARO Supplement Reissued August 2016 Revised October 2017 This report is subject to renewal August 2018. wwwAcc-es.org 1 (800) 423-6687 1 (562) 699-0643 A Subsidiary of the International Code Councile DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: SESFOAM 4008 LOUETTA ROAD, #538 SPRING, TEXAS 77388-4405 713) 239-0252 www.sesfoam.com EVALUATION SUBJECT: SUCRASEAL TM 0.5 AND SES FOAM 0.5 LB SPRAY: SPRAY -APPLIED POLYURETHANE FOAM PLASTIC INSULATION 1.0 EVALUATION SCOPE Conformance to the following: Seal and Insulate with ENERGY STARS Program —Definitions and Testing Requirements for Residential Insulation, Version 1.0 Properties evaluated: Thermal resistance Surface -burning characteristics 2.0 PURPOSE OF THIS SUPPLEMENT This supplement is issued to certify that the insulation products described in Sections 2.0 through 8.0 of the master report ESR-3375 have been reviewed for compliance with the requirements of the Seal and Insulate with ENERGY STARS Program, as set forth in the document Definitions and Testing Requirements for Residential Insulation, Version 1.0. The insulation product covered by this supplement is defined as "Spray or Pour Foam Insulation." The requirements for testing laboratory qualification and product sampling, as well as the specific material and test standards and editions used in this evaluation, are as set forth in the applicable documentation noted in Section 6.0 of the master evaluation report. 3.0 DEFINITIONS The following definitions are from Definitions and Testing Requirements for Residential Insulation, Version 1.0, and are applicable to the subject of this report. 3.1 General Definitions: Insulation: Any material mainly used to slow down heat flow. It may be mineral or organic, fibrous, cellular, or reflective aluminum foil). It may be in rigid, semi -rigid, flexible, or loose -fill form. 3.2 Insulation Product Definitions: Spray or Pour Foam Insulation: A thermal insulating material that is sprayed or poured (as a gel or foamy liquid) into place, and expands or sets into a cellular foam and cures at the point of installation through a chemical reaction. Foamed materials include, but are not limited to polyurethane, polyisocyan u rate, phenolic, and cementitious insulation. 3.3 Insulation Performance Definitions: R-value: The inverse of the time rate of heat flow through a body from one of its bounding surfaces to the other surface for a unit temperature difference between the two surfaces, under steady state conditions, per unit area. For the purposes of the CC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed or its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, asasanendorsementofihesubjectofthereportorarecommendationf to anyfinding or other matter in this report, or as to any product covered by the report. Copyright @ 2017 ICC Evaluation Service, LLC. All rights reserved. Page 6 of 11 r" __` , . - 1- 1 __ -_ - - ESR-3375 I Most Widely Accepted and Trusted Page 7 of 11 Seal and Insulate with ENERGY STARO program, Imperial units will only be accepted [(h ft2_ *F)/Btu]. Smoke -Development Index: The characteristic of a material to emit smoke when exposed to flame or fire compared to red oak and inorganic cement. Flame -Spread Index: The characteristic of a material to resist the spreading of flames when exposed to flame or fire compared to red oak and inorganic cement. 3.4 Thermal Resistance: The insulation has the thermal resistance R-values as noted in Table 1 of ESR-3375, based upon testing. 3.5 Installation: 3.5.1 General: The installation of the insulation must be in accordance with the requirements set forth in Sections 4.0 and 5.0 (as applicable) of ESR-3375. The insulation is manufactured on -site by spray polyurethane foam applicators meeting the qualification requirements of SES Foam. The following information on personal protective equipment and ventilation requirements is reprinted from the SES Foam published installation instructions: F. SAFETY 3. PERSONAL PROTECTIVE EQUIPMENT (PPE): a. Skin: Wear gloves, coveralls, apron and boots as necessary to prevent contact of liquid components or partially -cured SPF with skin. When handling liquid components, gloves should be made of nitrile, neoprene, butyl or PVC. b. Eyes: Protect eyes while handling liquid components or spraying with safety goggles or safety goggles and a face shield. During spray application, eye protection may be provided by a full -face or hood respirator. c. Respiration: Firms engaged in the application of SES Foam systems must have a written respiratory protection program for employees engaged in handling or applying SES Foam materials. Depending on the situation, respiratory protection may include dust masks, air -purifying respirators (APR), powered air -purifying respirators (PAPR), or supplied -air respirators (SAR). 4. VENTILATION: Provide ventilation and other engineering controls to exhaust vapors from work areas and to protect building occupants and other trades." 3.5.2 Occupancy Time after Installation: The re-entry or re -occupancy time shall be in accordance with the manufacturer's installation instructions, which state the following: G. RE-ENTRY SucraseaITM 0.5 reacts and cures within seconds of application. Re-entry times will vary depending on factors including ventilation. Typically, ventilation is continued for 24 hours following the conclusion of spray application and re-entry may occur at that time." 3.5.3 Figures: The figures shown represent general installations of the insulation in the following applications: above -grade wall, below -grade wall, vented and unvented crawl space, unvented cathedral ceiling, and vented and unvented attic. These figures are for illustration purposes and are not to be construed or used as construction documents. This supplement expires concurrently with the master report, reissued August 2016 and revised October 16, 2017 ESR-3375 I Most Widely Accepted and Trusted Page 8 of I I 000 0 0 0 0 0 0 00 0 00 , 0000 0 00000()0 0<)O0 '0000000000 0 00000 000000 0 00 00 0 0(0)0 00 00000 000,0 00000OC0000000 00 000 :) 0 0 00 00 () '00 0 0 0 00 0()00 '00 00 0000 10 0 0016 (D 0 000 000000000 000 0 00 0000000000, Interior Partition 0000 OC000000000 000 0000< O 0, () o 0, 0 c Interior Finished Surface 00000 00 0 00 0 (1/2-inch Sheetrock) 000 <)O OC 0 000 C100000 0 1C, 0 0 00000 0 000 01 SUCRASEAL7 0.5 or o 00 0 SES Foam 0.5 lb Spray000000C, C00000O() 000010-no 000( 0000 0 000 Exterior Sheathing00 0-010-(o 000, 0000< 0 000 SUCRASEAJM0.5 SES FOAM 0.5 LB SPRAY ABOVE GRADE WALL INSULATION SES 05-1 062914 ESR-3375 I Most Widely Accepted and Thisted Page 9 of I I Masonry Block Typical) Interior Finish Surface 112-inch Sheetrock) 2" x 4" Studs SUCRASEAL!"O.5 SES Foam 0.5 lb Spray SUCRASEALTM 0.5 BELOW GRADE WALL INSULATION SES 05-2 062914SESFOAM0.5 LB SPRAY (Insulation on Interior Side of WaIll I I I Baffle to provide air space between Thermal insulation and roof Barrier* deck. ( as required bylocalcode) FA Vented Soffit SUCRASEACM 0.5 or SES Foam 0.5 lb Spray Where attic entry is for the SES Foam 0.5 lb Spray service of utilities only, thermal and igniton barrier on the attic side of the spray foam surface may be omitted. SUCRASEALTM 0.5 SES FOAM 0.5 LB SPRAY T VENTED ATTIC: FLOOR / SOFFIT SES 05-3 062914 - 1 ESR-3375 I Most Widely Accepted and Thisted Page 10 of 11 Subfloor SUCRASEALTm 0.5 or SES Foam 0.5 lb Spray 000*o.'o* Header—. Joist Floor Cross Section Thermal Barrier* as required by xterior Grade localcode) 6" Min Footer----, Vapor Barrier Where crawlspace entry is for the service of utilities only, thermal and igniton barrier on the crawlspace si de of the spray foam surface may be omitted. SUCRASEAP0.5 SES FOAM 0.5 LB SPRAY CRAWLSPACE: VENTED SES 05-4 062914 Subfioor Joist Thermal Barrier* as required by xterior Grade localcode) Ax/ SUCRASEO' 0.5 or SES Foam 0.5 lb Spray T Footer----., 6" Min Vapor Barrier Where crawlspace entry is for the service of utilities only, thermal and igniton barrier on the crawlspace side of the spray foam surface may be omitted. SUCRASEAP 0.5 CRAWLSPACE: UNIVENTED SES 05-5 062914SESFOAM0.5 LB SPRAY I F ESR-3375 I Most Widely Accepted and Trusted Page 11 of 11 Note: In cold climates, embed metal connector plates in spray foam to prevent winter -time condensation. SUCRASEAL TM 0.5 or SES Foam 0.5 1b Spray Roof Sheathing o0oo 0 Truss Top Cord Rafter errmal Barrier* Ta equired by local code) Note: Local building code may require the use of a vapor retarder in cold climate zones. Where attic entry is for the Ceiling / Thermal Barrier service of utilities only, thermal as required by local building code. and igniton barrier on the attic side of the spray foam surface may be omitted. SUCRASEAZM 0.5 SES FOAM 0.5 LB SPRAY LINVENTED ATTIC / INSULATED ROOF DECK SES 05-6I 062914I TM 0 0SUCRASEAL0.5 or 0 0 '0> SES Foam 0.5 lb Spray 0 0 0 0 0 0tospecifiedthickness. 0 010 Roof Sheathing 0 0 0 0 0 0 0 0 0 0 0 0 - 0 0 Thermal Barrier as Rafter required by code. Note: The local building code may require the installation of a vapor barrier in cold climate zones. SUCRASEAJM0.5 CATHEDRAL CEILING SES 05-7 062914SESFOAM0.5 LB SPRAY I I I I Lumber design values are in accordance with ANSI/TPI.1 section 6.3 These truss designs rely on lumber values established by others. RECORD COPY IT-11 MiTek USA, Inc. I 6904 Parme cast B vd. Site Information: TVap FL;361'4115 Customer lnfo: Linton Enterprises, Inc. Project Name: Parker Residence Model: er Residence Lot/Block: TBD Subdivision: TBD Address: 819 Palmetto Avenue City: Sanford State: FL Name Address and License # of Structural Engineer of Record, If there Name: License #:' Allwark must be done in strict accordance with the Address: Approved Certificate of Appropriateness City: State: Building does W approve any work ouwde't is scope Me fl6r CDMPI, General Truss Engineering Criteria & Design Loads (Ind ividuaMMWIFUHAVA-MiNg"s Show SpelcIaY Load ingConditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 140 mph Roof Load: 40.0 psf Floor Load: N/A psf 744031 - This package includes 42 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss, Design Engineer and this index sheet conforms to 61 G1 5-31.003, section 5 of the Florida Board of Professional Engineers Rules. N::O:: Seal# Truss N No.Seal# Truss Name Date 1 T1 4165133 1 AO 1 15/30/18 118 1 T1 41651501 D06 15/30/18 12 T1 4165134 1 A02 15/30/18 119 1 TI 41651511 D07 15/30/18 13 1 T1 4165135 1 A03G 15/30/18 120 T1 41651521 E01 15/30/18 14 T1 4165136 1 A04G 15/30/18 121 1 T1 4165153 1 E02 15/30/18 1 15 T1 4165137 1 A05 15/30/18 122 1 T1 4165154 1 E03 15/30/18 16 T 14165138 1 A06 15/30/18 123 J T1 4165155 1 F01 15/30/18 17 T1 4165139 1 A07 15/30/1,8 124 1 T1 4165156 1 F02 15/30/18 18 1 T1 4165140 1 BO 1 15/30/18 125 1 T1 4165157 1 F03 15/30/18 1 19 1 T1 41651411 B02 15/30/18 126 1 T1 4165158 1 G01 15/30/18 1 110 1 T1 4165142 1 B03 15/30/18, 127 1 T1 4165159 1 G02 15/30/18 Ill I T1 4165143 1 CO 1 15/30/18 128 1 T1 41651601 G03G 15/30/18 112 1 T1 4165144 1 CO2 15/30/18 129 1 T1 41651611 HO 1 5/30/18 113 1 T1 41651451 D01 15/30/18 13Q I T14165162 I H02 5/30/18 114 1 T1 41651461 D02 15/30/18 131 1 T1 4165163 1 H03 15/30/18 11,5 1 T1 41651471 D03, 15/30/18 132 1 T1 4165164 1 H04 15/30/18 116 1 T1 41651481 D04 15/30/18 133 -1 T1 41651651 K01 15/30/18 117 1 T1 4165149 1 D05 15/30/18 134 1 T1 4165166 1 K02 15/30/18 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by American Builders Supply, Inc.. Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 3A tvpo&, 10 4--9 1 I N E N,'-. 8.182 STATE OF '144 Z 0 R IV N J* 10NA Ill Ill I%%% J quin, lezPENo.68182 M ekUS lnc.FLCert6634 69 , Park East Blvd. Tampa FL 33610 Dat May 30,201.8 Velez, Joaquin I of 2 MA A o"'IlUll. C-AP Mlw Aum OA on ZI "k) Pi Ma-j;$fqq,.A RE: 744031 - Site Information: Customer Info: Linton Enterprises, Inc. Project Name: Parker Residence Model: Parker Residence Lot/Block: TBID Subdivision: TBID Address: 819 Palmetto Avenue City: Sanford State: FL No. Seal# Truss Name Date 135 T1 4165167 1 MO 1 15/30/181 136 T1 4165,168 1 M02 15/30/18 137, T14165169 I PB1 15/30/18 1 138 1 T1 4165170 1 PB2 16/30/18 1 39 1 T1 41651711 PB3 15/30/18 140 1 T1 4165172 1 PB4 15/30/18 1 141 J T1 4165173 1 RG 1 15/30/18 142 1 T1 4165174 1 VT1 15/30/18 1 2 of 2 Job Truss Truss ype y Ply T14165133 744031 A01 GABLE 1 Job Reference (optional) American buiiaers buppiy, winter Haven, I-LdJbt5U 05. 10 6 Mar I I ZU I0 IVI I I UK I I IUUbLl I eb, I I 1G. vveu iviuy ou uu.z I :zo zu io r dye i ID:pBo2QD04UzF-Agn3M51CIGzTvbv-rsgTdtCAvKPxvHyy?p4nczOLWWVbeBH5ZIrQUIzBOfB 4-1 L4-8-4 -10-41 21,10-4 1 M-61%4 11-1 %6-0 48-6-0 0 4 I12-0-0 A42 _,f_2 2_2_. _0_. 2_ SX6 5x6 6.00 F12 5 86 6 87 7 8 4x6 13 35 34 33 32 3X8 '- 31 30 " 27 25 23 21 1. 17 16 15 4x6 3X6 7x8 ZORI G___ 3x6 = 3x6 7x8 3XG = 3X6 - SX8 4x6 = Scale: 118"-l' 1-4-2 17-8- 2 0-112-4 2 __ 15 2_ _ 2-010-1253-111.14 Z8-,1,1-,142I .-6-0 48-6-0 7-4- 3_._ _ _14 _ _0 _,_ 2_ _ 7-6-4 12-0-0 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [4:0-1-9,0-0-131, [5:0-3-0,0-2-0], [8:0-3-0,0-2-01, [16:0-3-8, Edge], [19:0-5-12,0-3-41, [29:0-6-12,0-3-41, [41:0-2-0,0-1-121, [45:0-0-10,0-2-81, 46:0-1-11,0-1-01, [48:0-1-11,0-1-01, [50:0-1-11,0-1-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES- GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.69 Vert(LL) -0.32 20-22 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.98 Verl(CT) -0.66 21-23 >836 240 BCLL 0.0 Rep Stress Incr YES WB 0.86 Horz(CT) 0.20 13 n/a n/a BCDL 10.0 Code FBC2017fTP12014 M, Wind(LL) 0.27 16-17 >999 240 Weight: 473 lb FT 20% LUMBER- BRACING- TOPCHORD 2x4 SP N0.2 TOPCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORD 2x4 SP N0.2 *Except* BOTCHORD Rigid ceiling directly applied. 19-29: 2x4 S P M 31 WEBS 1 Row at midpt 11-19, 41-42 WEBS 2x4 SP No.3 *Except* JOINTS I Brace at Jt(S): 38, 39, 40, 24, 22, 26, 20, 42, 43, 45 4-40,9-40;'2x6SP 240OF 2.OE, 1-31: 2x4 SP No.2 OTHERS 2X4 SP No.3 REACTIONS. All bearings 4-2-0 except at=length) 13=0-8-0. lb) - Max Horz 35=-403(LC 13) MaxUplift All uplift 100 lb or less atioint(s) except 35=-470(LC 12), 34=-371 (LC 2), 33=-221 (LC 13), 13=-538(LC 13) MaxGrav All reactions 250 lb or less atjoint(s) 34 except 35=2044(LC 2), 33=893(LC 27), 13=2383(LC 2) FORCES. (1b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2509/532, 2-4=-3119/548, 4-5=-1560/391, 5-6=-1385/392, 6-7=-1385/392, 7-8=-1667/468, 8-9=-1838/485, 9-1 1=-4004/824,11-12=-4309/948, 12-13=-4729/1032, 1-35=-1970/453 BOTCHORD 34-35=-196/363, 33-34=-196/363, 32-33=-196/363, 31-32=-306/1070, 30-31=-580/1541, 27-30=-146/2830, 25-27=0/3558, 23-25=0/3558, 21-23=0/3558, 17-21=-72/3152, 16-17=-492/1988, 15-16=-810/4177,13-15=-810/4177,26-29=-99/2462,24-26=-298/999, 22-24=-530/532, 20-2=-4651806,,19-20=-347/1,936 WEBS 31-44=-1003/184, 2-44=-963/177, 2-43=0/744, 29-43=0/743, 29-30=0/1045, 29-42=0/960, 36-42=0/955,17-19=0/891, 19-37 0/1313, 4-36=-1496/291, 36-38=-1 509/292, 38-41=-1477/296, 40-41=-2290/701,39-40=-1 887/602, 37-39=-1942/599, 9-37=-1940/599, 1-45=-351/2246,31-45=-324/2082, 11-19=-552/522, 16-19=-392/1957, 12-16=-506/360 29-31=-192/1859, 5-38-0/479, 8-39=-63/805, 6-40=-285/242, 26-30=-1994/0, 26-27=0/407,24-27=-993/41,17-20=-1682/0, 20-21=-1 1/310, 21-22=-705/118, 7-40--462/126, 41-42=-1 119/470, 42-43=-1 1081451, 43-44=-1 106/446, 44-45=-1043/425, 32-45=-1 179/438 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6-Opsf; BCDL=6.opsf; h=25ft; Cat. 11; Exp C; Encl., Joaquin Velez PE No.68182 GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exteriol-I 0-1-12 to 4-11-15, Interior(l) 4-11-15 to 16-10-4, Exterior(2) MiTek USA, Inc. FIL Cert 6634 16-10-4 to 33-8-9, Interior(l) 33-8-9 to 49-10-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 6904 Parke East Blvd. Tampa Fl. 33610 plate grip DOL=1.60 Date: 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry May 30,2018GableEndDetailsasapplicable, or consult qualified buildinq desiqw as per ANSIfTPI 1 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED ARTEK REFERANCE PAGE M11-7473 rev. 10/03,2015 BEFORE USE. Design valid for rise only with Mifek(b connectors. This design Is based only upon parameters shown, and is for an individual building component, not Nil" a truss system. Before use, the building designer must verify ]he applicability of design pafarnoteis and properly incorporate this design into the overall building design. Bracing indiculed Is to buckling of Individual truss web andfor chord mernbers only. Additional lemporary and permanent bracing MiTek' prevent is always required for stability and to prevent collapse w[h possible personal injury and property darnage, For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems. se-eANSWIl Quaffly Criteft DSR-89 and BCSI BuffdIng Component 6904 Parke East Blvd. Safety kdonnatildrovallable from Truss Plate institute, 218 N. Lee Street,,Sulto 312, Alexandtict, VA 22,114. Tampa, FL 33610 Job Truss Truss Type Qt' Ply T14165133 744031 A01 GABLE I I Job Reference (optional) American t3unaers buppiy, , vvinier Haven, V L 338BU u.13u s mar i i 2U1 1:3 MI I OK maU$Tnes, Inc. vvea may ju Ub:21:2b 2U1 b Fage 2 ID:pBo2QD04UzF Agn3M51CIGzTvbv-rsgTdtCAvKPxvHyy?p4nczOLWWVbeBH5ZIrOUlzBOf8 NOTES- 5) All plates are 2 4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Ceiling dead load (5.0 psf) on member(s). 4-36, 36-38, 38-41, 40-41, 39-40, 37-39, 9-37 10) Bottom chord livejoad (40.0.psf) and additional bottom chord dead load (5.0 psf) applied only to room. 26-29, 24-26, 22-24, 20-22, 19-20 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 470 Ito uplift at joint 35, 371 lb uplift at joint 34, 221 lb uplift at joint 33 and 538 lb uplift at joint 13. 12) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and-1/2" gypsum sheetrock be applied directly to the bottom chord. 13) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. WARNING - Verify design parameters and REAO NOTES ON THIS AND INCLUOED MITEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only vAlh MiTek0 connectors. This design is based only upon parameters shown, and Is for an individual building,coruponent not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into Me, overall building design. Bracing Indicaled ls to prevent buckling of individual Ituss web and/or chord mernbers only. Addilional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property clarnage. For general guidarice regarding the fabilcallon. storag . e, delivery, erecfion and bracing of trusses and truss systems. seeANS&VI1 Quaffly Criteria, DSB-89 and BCS1 BuDdIng Component 6904 Farke East Blvd. Safety Intannationavallable frorn Truss Plate Institute, 218 N. Lee Street, Sulle3l 2, Alexandra, VA 22314. Tampa, FL 33610 Job T ss Truss Type Qty Ply T14165134 744031 A02 ATTIC 4 1 Job Reference (optional) Anferican Builders Supply, Winier Haven, FL 33880 8A 30 s Mar i i 20i 8 MiTek industries, Inc. Wed May 30 06:21:28 201a Page 1 ID:pBo2QDQ4UzF-Agn3M516IGzTvbv-FRMbGuE3CFnWmlgXgyjeUEcOpqkXtrZjYFG344dzBOf5 1_4 11-4 6 IQ41 2f-W-4 1 2-10-4 Ll 9-4 1 L4-10-0 0-4-0 4 -10-0 8 6-0 2 2_ 5_ 2 211 2 g. 0_ Scale 11:94 0 6. 00 F1 _2 5x6 2x4 11 5x6 5 so 6 51 7 4x6 7, 14 35 34 33 31 30 28 26 24 23 20 19 18 it 2x4 11 1.5x8 STP i.5x8 STP 5X8 4X6 - 2x4 11 3x10MT20HS= 6x10 = 3x4 11 6x 10 MT20HS 5x8 MT20HS 11 46 Exio 2x4 11 8x14 2x4 11 3x10 7 14-8-4 17-.8-,6 Z_ 40-' - 125-11-14 8-111-,142Z_i_ 2_6-1 31-94 34-10-0 04-01___ 45-10-0 86-0 1 4-2 7-4-2 1 _ 1 3--1-01-4 i_Tb 2_ 1 4 _ 1 12_,_ '_0_' 0 I i 2_ _0 11 Plate Offsets (X,Y)-- 1:0-3-0,0-1-8],15:0-3-0,0-2-01, [7:0-3-0,0-2-01, 11:0-4-0, Edge], [13:0-8-0, Edge], [14:0-1-4,0-1-81, [21:0-5-820-2-8], [32:0-8-0,0-2-81, [34:0-2-12,0-1 121, f36:0-3-0,0-1-2] LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (Ioc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.B1 Vert(LL) 0.42 21-22 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.94 Vert(CT) 0.84 22-25 >682 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES, WB 0.82 Horz(CT) 0.37 14 n/a n/a BCDL 10 0 Code FBC2017fTP12014 Matrix -AS Wind(LL) OA3 19-20 >999 240 Weight: 449 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SO No.2 *Except* TOPCHORD Structural wood sheathing directly applied, except end verticals. 7-11: 2x6 SP No.21 11-14: 2x8 SP 240OF 2.OE BOTCHORD Rigid ceiling directly applied. Except: BOT CHORD 2x4 SP No.2 *Except* 10-18,36-37: 2x4 SP No.3, 13-16,17-24,24-31: 2x4 SP M 30 WEBS WEBS 2x4 SP No.3 *Except* JOINTS 8-43,4-43: 2x6 SP 240OF 2.OE, 1-34,16-19: 2x4 SP No.2 OTHERS 2x8 SP 240OF 2.OE LBR SCAB 11-14 2x8 SP 240OF 2.OE one side REACTIONS, (lb/size) 35=2255/0-8-0, 14=2203/0-8-0 Max Horz 35=-369(LC 13) Max Uplift 35=-380(LC 12), 14=-478(LC 13) Max Grav 35=2485(LC 2), 14=2351 (LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHbRD 1-2=-3027/659,2-4=-382gn961 4-5=-2138/699, 5-6=-1914/671, 6-7=-1914/671, 7-8=-2129/681, 8-9=-3761/806, 9-10-4781/1116, 10-12=-4902/1040, 12-13=-5954/1268, 13-14=-1044/286, 1-35=-2414/609 BOTCHORD 34-35=-184/345, 33-34=-633/1244, 30-33=-126/2641, 28-30=0/3799, 26-28=0/3799, 23-26=0/3799, 20-23=-278/3988, 19-20=-917/3271, 15-16=-.1 074/5583, 13-15=-1 074/5583, 29-32=-432/2949, 27-29=-477/1224, 25-27=-836/179, 22-25=-886/359, 21-22=-714/1119 WEBS 2-34=-1 133/311, 32-33=0/1 151, 32-39=0/1 059, 20-21 =-40/683, 21-40=-27/1078, 4-39=-1 542/310, 39-41 =-I 546/309, 41-43=-1 503/312, 42-43=-1 503/312, 40-42=-1 549/312, 8-40=-1 547/313, 1-34=-464/2705, 2-32=-53/951, 32-34=-416/2136, 5-41 =_1 04/796; 7-42 ' =-89/752, 6-43=-302/231,12-16=-1 476/592, 12-15=0/277, 27-28=-78/306, 29-33=-2206/0, 29-30=-58/625, 27-30=-1651/285, 20-22=-1420/83, 22-23=-154/252, 23-25 644175119-21 =-9231823, 9-19 1 366/187,16-19=-433/3492, 9-16 498/2149, 19-21=-390/iO47 10-0-0 oc bracing: 16-18 1 Row at micipt 12-16, 9-21, 9-19 1 Brace at Jt(s): 41, 42, 43, 25, 27, 29, 22 NOTES- 1) Attached 12-5-4,scab,l 1 to 14, front face(s) 2x8 SP 240OF 2.OE with 2 row(s) of 10d (0.131 'xX) nails spaced 9" o.c.except : starting I at 7-9-12 from end at joint 1.1, nail 2 row(s) at 2" o.c. for 2-7-13. 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-10; Vult=140mph (-seconcl gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpj=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 4-11-15, Interior(l) 4-11-15 to 16-10-4, Exterior(2) 16-10-4 to 33-8-9, Interior(l) 33-8-9 to 48-2-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: Mav 30,2018 4101"'90*2 MT20 unless otherwise indicated. WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK RE FERANCE PAGE M11-7473re, 1010312015 BEFORE USE. Design valid for use only with MilekO connectors. This design Is based only upon parameters shown, and is for an individual building component, not IMFatrusssystem. Before use, ]he building designer must verify the applicability of design parameters and properly incorporate this design into rho overall building design. Bracing indicated is to prevent buckling ofindividual truss web andior chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. se.eANSW11 Quaffly Cffledd, DSB-89 and BCS1 Buffolbig Component 6904 Parke East Blvd. Safety Intonnallonavallable from Truss Plate InsfilUte, 218 N. Lee Street. Suite 312, Nexandrict, VA 22,114. Tampa, FL 33610 Job Truss Truss Type QtY Ply T14165134 744031 A02 ATTIC 4 1 Job Reference (optional) American Builders Supply, Winter Haven, I'L 33880 8.130 s Mar 11 2018 MI I eK Inclustries, Inc. vvea may Ju ub:21:2b 2u1I3 I -age 2 ID:pBo2QDQ4UzF—Agn3M51CIGzTvbv-FRMbGuE3CFnWmlgXgyeUEcOpqkXtrZjYFG344dzBOt5 NOTES- 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Ceiling dead load (5.0 psf) on member(s). 4-39, 39-41, 41-43, 42-43, 40-42, 8-40 10) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 29-32, 27-29, 25-27, 22-25, 21-22 11) Bearing at joint(s) 14 considers parallel to grain value using ANSIrFPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 12) Provide. mechanical connection (by others) of truss to bearing plate capable of withstanding 380 lb uplift at joint 35 and 478 lb uplift at joint 14. 13) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 14) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M*7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO conneclors. [his design is based only upoon p arameieis shown, and is for an individual building component. not a truss system. Before use, the building designer must verify the applicability of design paramelers and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual tFUSS web and/or chord members only. Additional lemporary and permanent bracing MiTek' is always required for stability and to prevent collapse YAM possible personal injury and property damage. For general guidance regarding the fabrication, storage. deltv e, erection and loracing of trusses and truss system& seeAhmmil Qualffy Cifferld, DSB-89 and BCS1 Bufldbng Component 6904 Parke East Blvd. Safety btfonnOtionCIVailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Nexandria, VA 22314. TamPa, FL 33610 Job Truss Truss Type oty Ply T14165135 744031 A03G ATTIC 5 Job Reference (optional) Ame r1can uuilciers bupply, winter Haven, -L J.Jb?5U .'. 11. - I I - I .. .. . I., - - 'y . . - ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-4bjtWyJqn5YfUg8goCkuUtGsXgdfEHGQdCWOIHzBOf? 7 4 2 14-8-4 16-110-4 21-10-4 26-10-4 4 34-10 0 4040 45 100 ' 08-r 4-2 7-4-2 2-2-0 5-0-0 5-0-0 2-1-8 2x4 11 5x6 Scale = 1:106.6 6.00 F12 5x6 5 6 7 WO 3x4 4x6 4x4 50 2 3 49 48 5XI 0 4 7 1 3x4 3x4 11 41 43 42 3x1 1 10 7x8 6x1 0 11 11 4x6 12 14-0-0 29 3 14 l 1.5X X, 5XI 4 6 52 63 54 56 56 57 31 5 69 60 6 9 33 30 28 26 6224 63 20 19 is 17 66 35 34 2x4 11 1.5x8 STP 3x10 11 LUS24 5x10 LUS24 7x8 = LUS24 7x8 = 6x6 = 4x1 2 7xg 2x4 11 LUS24 LUS24 LUS24 4x6 §x-8 = LUS24 4x6 7SX8 = LUS24 LUS24 4x6 LUS24 LUS24 LUS24 LUS24 LUS24 HHUS28-2 14-8-4 7_4_2 7 2s l 1- 14 31 9 4 34 10 0 4040 70 45100 4860 2_ f?'J 12 2 -14 _ , -10 1-11'1'4 2. Plate Offsets (X,Y)-- 5:0-3-0,0-2-0] [7:0-3-0,0-2-01, [11 -.0-4-0, Edge], [13:0-10-8, Edge], [16:0-2-8,0-4-41, [20:0-3-0,0-3-12], [21:0-5-8,0-2-81, 32:0-5-8,0-2-8j, [3b:0-b-410-0-14j, 36:0-1-9,0-1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/detl Ud PLATES GRIP TCILL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(I-L) -0.31 23-26 >999 360 MT20' 244/190 TCDL -11.0 Lumber DOL 1.25 BC 0.72 Vert(CT) -0.58 23-26 >995 240 BCLL 0.0 Rep Stress Incr YES WB 0.82 Horz(CT) 0.29 14 n/a n/a BCDL 11.0 Code FBC2017/TP12014 Matrix MS Wind(LIL) 0.37 17 >999 240 Weight: 2437 lb FT = 20% LIUMBER- BRACING- TOPCHORD 2x6 SP N0.2 *Except* TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, 5-7: 2x4 SP No.2, 11-14: 2x8 SP 240OF 2.OE except end verticals. BOTCHORD 2x8 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. Except: 10-18,36-37:2x4SPNo.3.13-16:2x6SP240OF2.OE 6-0-0 oc bracing: 16-18 37-38,21-32: 2x4 SP No.2 JOINTS 1 Brace at 41, 42, 43, 25, 27, 29, 22 WEBS 2x4 SP No.3 *Except* 8-43,4-43: 2x6 SID No.2, 1-35: 2x8 SP No.2, 1-34,16-19: 2x4 SP No.2 REACTIONS. (Ilb/size) 35-1) 4379/0-8-0,14=7830/0-8-0 Wax Horz 35=-368(LC 29) Max Uplift 35=-4293(LC 8), 14=-2706(LC 9) FORCES. (1b) - Max. Comp./Max. Ten. - All forces 250 (11b) or less except when shown. TOPCHORD 1-,2=-16548/5027, 2-4=-17344/5744, 4-5=-5257/1792, 5-6=-4655/1611, 6-7=-4654/1610, 7-8=-5267/1771, 8-9=-15767/5272, 9-10=-18811/6629, 10-12=-18979/6538, 12-13=-22856/7841, 13-14=-3492/1237, 1-35=-13420/4034 BOTCHORD 34-35=-410/997, 33-34=-3036/10814, 30-33=-3906/14235, 28-30=-4863/17070, 26-28=-4863/17070, 23-26=-4863/17070, 20-23=-5586/15967, 19-20=-5353/12195, 18-19---589/1794,15-16=-7136/21222, 13-15=-7136/21222,29-32=-2629/5270I 27-29=-1'369/1368, 25-27--2398/269,22-25=-1618/1101, 21-22=-1047/3952 WEBS 2-34=-3Q72/1217, 32-33=-1460/4516, 32-39=-1427/4723, 20-21=-209715991, 21-40=-1537/4494, 4-39=-10552/3746, 39-41=-10559/3749, 41-43=-10376/3701, 42-43=-1 0377/3701, 40-42=-1 0561/3754, 8-40=-1 0554/3753, 1-34=-4317/14135, 2-32=-517/1012, 32-34--2178/4400, 5-41 =-805/2541, 7-42=-775/2515, 6-43=-476/293, 12-16=-5062/1906,12-15=-425/1588, 25-26=-4128/687, 27-28=-711/1294, 29-33=-4591/1371, 29-30=-535/1419, 27-30=-3753/1785, 20-22=-4715/796, 22-23=-364/1452, 23-25=-1868/997, 9-21 =- 1128/2634, 9-19=-4610/1154, 16-19=-4202/13185, 9-16=-2319/6494, 19-21 =-972/31 00 NOTES- 1) 5-ply truss to be connected together with 1 Od (0. 131 "xX) nails as follows: Top chordsdonnected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-8-0 oc, 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-9 oc- Webs connected as follows: 2x4 - .1 row at 0-9-0 oc, Except member 40-20 2x4 - 1 row at 0-6-0 oc, 2x6 - 2 rows staggered at 0-9-0 Joaquin Velez PE No.68182 0 cm I I MiTek USA, Inc. FL Cart 6634 Attach TC&BC w/1/2" clam. bolts(ASTM A-307) in the center of the member wtwashers at 4-0-0 oc. 6904 Parke EastBlvd. Tampa FL 33610 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to Date: ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. May 1 30,,2018 wARAfwa - verify design parameters and READ NOTES ON THIS AND INCLUDED UITEK REFERANCE PAGE M11-7473 rev. 10103)2015 BEFORE USE. Design valid for use only vAlf) MilekO connectors. Ihis design is based only upon parameters shown. and is for an individual building component not a truss system. Before use, the bulldinqclesigner inust verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated isto prevent buckling ofindividual trussweband/or chord mernbers only. Addilion(illeryiporarycndpoiff arienitAj,-ing MiTek' is always required for stability and to prevent collapse ,Mh ,ble personal injury and property damage. For general guidance regarding the falb0cation, storage. delivery, erection and bracin m s, seeANXMI1 QualflyCrilterld, DSB-89 and BCSIBulding Component 6904 Parke East Blvd. g0ftrUSSeSCJndtR1SSSYsIe Sofstyintagnoilionavallalble from Truss Plate Institute, 218 N. Lee street. Sdle312. PJexandrla, VA 22,314. TaMpaT FL 33610 Job Truss Truss Type Qty Ply T14165135 744031 A03G ATTIC 1 5 Job Reference (optional) American Builders supply, Winter Haven, F-L 3388U u.iju s ivar 1 1 ZUR5 MI I eK MULISIrle6, 111G. VVeU IVIUY JU UD:,f I * 50ZU10 rdYe ID:pBo2QDQ4UzF-Agn3M5lCiGzTvbv-YoHFkIJSYPgW6pjtawG704plGYzuzkWassGyqjzBOf- NOTES- 4) Wind: ASCE 7-10; Vutt=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf, BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) All plates are 3x6 MT20 unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Ceiling dead load (5.0 pst) on member(s). 4-39, 39-41, 41-43, 42-43, 40-42, 8-40 10) Bottom chord live load (4b.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 29-32, 27-29, 25-27, 22-25, 21-22 11) Bearing at joint(s),14 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4293 lb uplift at joint 35 and 2706 lb uplift at joint 14. 13) Load case(s) 1, 2, 3, 4, 5, 6, 7; 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 14) Use Simpson Strong -Tie LUS24 (4-1 Od Girder, 2-1 Od Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 2-0-12 from the left end to 28-0-12 to connect truss(es) to.front face of bottom chord. 15) Use Simpson Strong -Tie HHUS28-2 (22-1 Od Girder, 8-10d Truss, Single Ply Girder) or equivalent at 28-11-12 from the left end to connect truss(es) to front face of bottom chord. 16) Fill all nail holes where hanger is in contact with lumber. 17) Hanger (s) of other connection device(s) shall be provided sufficient to support concentrated load(s) 549 Ito down and 238 In up at 0-3-10, 539 lb down and 248 lb up at 2-0-12, 539 lb down and 248 lb up at 4-0-12, 539 lb down and 248 lb up at 6-0-12, 539 lb down and 248 lb up at 8-0-12, and 539 lb down and 248 lb up at 10-0-12, and 2067 lb down and 859 lb up at 12-0-12 on top chord. The design/selection of such connection device(s) is the responsibility of others. 18) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. LOAD CASIE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 5-51=-62, 5-7=-62, 7-13=-62, 13-14=-87, 18-35=-22, 17-18=-22, 16-44=-22, 22-32=-32, 21-22=-32, 4-8=-10 Concentrated Loads (lb) Vert: 3=-499 31 =-626(F) 20=-3294(F) 1 =-534 23=-630(F) 47=-499 48=-499 49=-499 50=-499 51 =-2027 52=-626(F) 53=-626(F) 54=-626(F) 55=-626(F) 56=-626(F) 57=-626(F) 58=-626(F) 59=-626(F) 60=-626(F) 61 =-630(F) 62=-630(F) 63=-630(F) Trapezoidal Loads (pit) Vert: 1=-132-to-51=-62 2) Dead + 0.75 Roof Live (balanced) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 5-51 =-52, 5-7=-52, 7-13=-52, 13-14=-77, 18-35=-22, 17-18=-22, 16-44=-22, 29-32=-92, 22-29=-92, 21-22=-92, 4-8=-1 0 Concentrated Loads (lb) Vert: 3=-435 31 =-518(F) 20=-3007(F) 1=-464 23=-520(F) 47=-435 48=-435 49=-435 50=-435 51=-1 770 52=-518(F) 53=-518(F) 54=-518(F) 55=-518(F) 56=-518(F) 57=-518(F) 58=-518(F) 59=-518(F) 60=-518(F) 61=-520(F) 62=-520(F) 63=-520(F) Trapezoidal Loads (pit) Vert: 1=-122-to-51=-52 3) Dead + Uninhabitable Attic Without Storage: Lumber Increase=1.25, Plate Increase=1,25 Uniform Loads (pit) Vert: 5-51=-22, 5-7=-22, 7-13=-22, 13-14=-47, 18-35=-42, 17-18=-42, 16-44=-42, 22-32=-32, 21-22=-32, 4-8=-10 Concentrated Loads (Jb) Vert: 3=-363 31=-302(F) 20=-2450(F) 1 =-374 23=-297(F) 47=-363 48=-363 49=-363 50=-363 51 =-1482 52=-302(F) 53=-302(F) 54=-302(F) 55=-302(F) 56=-302(F) 57=-302(F) 58=-302(F) 59=-302(F) 60=-302(F) 61 =-297(F) 62=-297(F) 63=-297(F) Trapezoidal Loads (pit) Vert: 1=-92-to-51=-22 4) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51=6, 5-7=48, 7-13=25, 13-14=12, 18-35=-12, 17-18=-12, 16-44=-12, 22-32=-18, 21-22=-18, 4-8=-6 Harz: 1-5=-18, 7-14=37 Concentrated Loads (Ilb) Vert: 3=221 31 =209(F) 20=1 704(F) 1 =226 23=215(F) 47=221 48=221 49=221 50=221 51 =832 52=209(F) 53=209(F) 54=209(F) 55=209(F) 56=209(F) 57=209(F) 58=209(F) 59=209(F) 60=209(F) 61 =215(F) 62=215(F) 63=215(F) Trapezoidal Loads (pit) Vert: 1=-64-to-51=6 Dead + 0.6 IMWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51=25, 5-7=48, 7-13=6, 13-14=-7, 18-35=-12, 17-18=-12, 16-44=-12, 22-32=-18, 21-22=-18, 4-8=-6 Horz: 1-5=-37. 7-14=18 Concentrated Loads (lb) . Vert: 3=202 31 =209(F) 20=1 704(F) 1 =219 23=215(F) 47=202 48=202 49=202 50=202 51 =813 52=209(F) 53=209(F) 54=209(1) 55=209(F) 56=209(F) 57=209(F) 58=209(F) 59=209(F) 60=209(F) 61=215(F) 62=21 5fl 63=215(F) Trapezoidal Loads (pit) Vert: 1=-45-to-51=25 6) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51 =-21, 5-7=21, 7-13=-2, 13-14=-27, 18-35=-22, 17-18=-22, 16-44=-22, 22-32=-32, 21-22=-32, 4-8=-1 0 Horz: 1-5=-1, 7-14=20 Concentrated Loads (lb) Vert: 3=248 31 =219(F) 20=1 714(F) 1=238 23=225(F) 47=248 48=248 49=248 50=248 51=859 52=219(F) 53=219(F) 54=219(F) 55=219(F) 56=219(F) 57=219(F) 58=219(F) 59=219(F) 60=219(F) 61=225(F) 62=225(F) 63=225(F) Trapezoidal Loads (plf) Vert: 1=-92-to-51=-21 7) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 on nine WARNING - Verify design parameters and READ NOTES ON THIS AND MCLUDED MrTEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(9 connectors: This design is based only upon parameters shown. and Is for an Individual building component. not a truss system. Before use. the building designer i nusi verify the applicability of design parameters and properly incorporate this design into the overall to buckling individual truss and/or chord members only. Additional temporary and permanent bracing MiTek' building design. Bracing indicated is prevent of web is always required for stability and to prevent collapse with possible personal injury and properly darnage. rot _general guidance regarding the 6904 Parke East Blvd. fabrication, storage. delivery. erection and bracing Of tRIWS and truss Systems, se-e-AArSYMIF aualoy Crftda, DSB-SP and BCS1 BuIldIng Component Tampa, FL 33610SafetyhiffafmatimrvailablefromIf= Plate Institute, 218 N. Lee, Street, Suite 312. AleXandria, VA 22,114. Job Truss Truss Type QtY , Ply T14165135 744031 A03G ATTIC 1 5' Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 8.130 s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:21:35 2018 Page 3 ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-YoHFkIJSYPgW6pjtawG704piGYzuzkWassGyqjzBOf- LOAD CASE(S) Standard Uniform Loads (pit) Vert: 5-51=-2, 5-7=21, 7-13=-21, 13-14=-46, 18-35=-22, 17-18=-22, 16-44=-22, 22-32=-32, 21-22=-32, 4-8=-10 Horz: 1-5=-20, 7-14=1 Concentrated Loads (lb) Vert: 3=229 31=219(F) 20=1714(F) 1=231 23=225(F) 47=22948=22949=229 50=229 51=840 52=219(F) 53=219(F) 54=219(F) 55=219(F) 56=219(F) 57=219(F) 58=219(F) 59=219(F) 60=219(F) 61 =225(F) 62=225(F) 63=225(F) Trapezoidal Loads (plf) Vert: 1=-73-to-51=-2 8) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pif) Vert: 5-51=48,5-7=22, 7-13=22, 13-14=9, 18-35=-12, 17-18=-12, 16-44=-12,22-32=-18, 21-22=-18, 4-8=-6 Horz: 1-5=-60, 7-14=34 Concentrated Loads (lb) Vert: 3-178 31 =209(F) 20=1 704(F) 1 =210 23=215(F) 47=1 78 48=1 78 49=1 78 50=1 78 51 =789 52=209(F) 53=209(F) 54=209(F) 55=209(F) 56=209(F) 57=209(F) 58=209(F) 59=209(F) 60=209(F) 61 =215(F) 62=215(F) 63=215(F) Trapezoidal Loads (plf) Vert: 1=-22-to-51=48 9) Dead + 0.6 MWFRS Wind (Pos- Internal) 2nd Parallel: Lumber Increase=1.60, Plate lncrease=1.60 Uniform Loads (plf) Vert: 5-51=22, 5-7=22, 7-13=48,13-14=35, 18-35=-12, 17-18=-12, 16-44=-12, 22-32=-18,21-22=-18, 4-8=-6 Horzi 1-5=-34, 7-14=60 Concentrated Loads (lb) Vert: 3=204 31 =209(F) 20=1 704(F) 1 =220 23=215(F) 47=204 48=204 49=204 50=204 51 =816 52=209(F) 53=209(F) 54=209(F) 55=209(F) 56=209(F) 57=209(F) 58=209(F) 59=209(F) 60=209(F) 61=215(F) 62=215(F) 63=215(F) Trapezoidal Loads (pit) Vert: 1=-48-to-51=22 10) Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd Parallel: Lumber Increase=1.60, Plate lnerease=1.60 Uniform Loads (plf) Vert: 5-51 =48, 5-7=22, 7-13=22, 13-14=9, 18-35=-1 2, 17-18=-1 2, 16-44=-1 2, 22-32=-1 8, 21-22=-1 8, 4-8=-6 Horz: 1-5=-60, 7-14=34 Concentrated Loads (lb) Vert: 3=1 78 31 =209(F) 20=1 704(F) 1 =210 23=215(F) 47=1 78 48=1 78 49=1 78 50=1 78 51 =789 52=209(F) 53=209(F) 54=209(F) 55=209(F) 56=209(F) 57=209(F) 58=209(F) 59=209(F) 60=209(F),61 =215(F) 62=215(F) 63=215(F) Trapezoidal Loads (pit) Vert: 1 =-22-to-51 =48 11) Dead + 0.6 MWFRS Wind (Pos. Internal) 4th Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51 =22, 5-7=22, 7-13=48, 13-14=35, 18-35=- 12, 17-18=- 12, 16-44=- 12, 22-32=- 18, 21-22=-1 8, 4-8=-6 Horz: 1-5=-34, 7-14=60 Concentrated Loads (1b) Vert: 3=204 31 =209(F) 20=1 704(F) 1 =220 23=215(F) 47=204 48=204 49=204 50=204 51 =816 52=209(F) 53=209(F) 54=209(F) 55=209(F) 56=209(F) 57=209(F) 58=209(F) 59=209(F) 60=209(F) 61 =215(F) 62=215(F) 63=215(F) Trapezoidal Loads (plf) Vert: 1 =-48-to-51 =22 12) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Unforrn Loads (pit) Vert: 5-51=21, 5-7=-5, 7-13=-5,13-14=-30, 18-35=-22, 17-18=-22, 16-44=-22, 22-32=-32, 21-22=-32, 4-8=-10 Horz: 1-5=-43,7-14=17 Concentrated Loads (11b) Vert: 3=206 31 =219(F) 20=1 714(F) 1 =222 23=225(F) 47=206 48=206 49=206 50=206 51 =817 52=219(F) 53=219(F) 54=219(F) 55=219(F) 56=219(F) 57=219(F) 58=219(F) 59=219(F) 60=219(F) 61=225(F) 62=225(F) 63=225(F) Trapezoidal Loads (plf) Vert: 1=-49-to-51=21 13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-51 =-5, 5-7=-5, 7-13=21, 13-14=-4, 18-35=-22, 17-18=-22, 16-44=-22, 22-32=-32, 21-22=-32, 4-8=-1 0 Horz: 1-5=-17, 7-14=43 Concentrated Loads (lb) Vert: 3=232 31=219(F) 20--1714(F) 1=232 23=225(F) 47=232 48=232 49=232 50=232 51=843 52=219(F) 53=219(F) 54=219(F) 55=219(F) 56=219(F) 57=219(F) 58=219(F) 59=219(F) 60=219(F) 61 =225(F) 62=225(F) 63=225(F) Trapezoidal Loads (plf) Vert: 1=-75-to-51=-5 14) Dead + Uninhalb. Attic Storage + Attic Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 5-51 =-22, 5-7=-22, 7-13=-22, 13-14=-47, 18-35=-22, 17-18=-22, 16-44=-22, 29-32=-1 12, 22-29=-1 12, 21-22=-1 12, 4-8=-10 Concentrated Loads (lb) Vert: 3=-244 31 =-1 94(F) 20=-1 801 (F) 1 =-255 23=-1 92(F) 47=-244 48=-244 49=-244 50=-244 51 =-998 52=-1 94(F) 53=-194(F) 54=-194(F) 55=-194(F) 56=-104(F) 57=-194(F) 58=-194(F) 59=-194(F) 60=-194(F) 61=-192(F) 62=-192(F) 63=-192(F) Trapezoidal Loads (plf) Vert: 1 =-92-to-51 =-22 15) Dead + Uninhabitable Attic Storage: Lumber Increase=1.00, Plate Increase=1.00 nntinijprl nn WARNING- Verify design parameters and READ NOTES ON THIS AND iNCLUDED urrEK REFERANCE PAGE MIP7473 rev. 1010312015 BEFORE USE. Design valid for use only With Mf1ek8 connectors. This design is based only upon parameters shown. and is for an Individual building component. not a truss system. Before use. the building designer must verify the applicability of design parameters and Properly incorporate this design Into the overall design. Bracing Indicated is to [Aickling of individual truss Web and/or chord members only, Additional temporary (Ind permanent U.Ing MiTek' building prevent Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the , fabrication, storage. delivery. erection and bracing of tftjsses and truss systems. s9eANS&VII Quaffly Ctiferld, DS949 and BCS1 Building Componont 6904 Parke East Blvd. Tampa, FL 33610SalotyInformatildnavailaHefromTnasPlateInstitute, 218 N. Lee Street, Suite 312. Nexandila, VA 22314. 1 Job Truss Truss Type oty , Ply T14165135 744031 A03G, ATTIC 1 5 Job Reference (optional) American Builders bupply, Winter Haven, F-1- 33880 b.iju s ar I I ZVI U Mi I eK inuustries, inc. vveu may ou uo:z i:oo zu io rdyv I D:pBo2QDQ4UzF-Agn3M51CIGzTvbv-YoHFkIJSYPgW6pjtawG704p1 GYzuzkWassGyqjzBOf- LOAD CASE(S) Standard Uniform Loads (pit) Vert: 5-51=-22, 5-7=-22, 7-13=-22, 13-14=-47, 18-35=-22, 17-18=-22, 16-44=-22, 29-32=-112, 22-29=-112, 21-22=-112, 4-8=-10 Concentrated Loads (lb) Vert: 3=-24431=-194(F) 20=-1801(F) 1=-25523=-192(F)47=-24448=-24449=-244 50=-244 51=-99852=-194(F) 53=-194(F) 54=-194(F) 55=-194(F) 56=-194(F) 57=-194(F) 58=-194(F) 59=-194(F) 60=-194(F) 61=-192(F) 62=-192(F) 63=-192(F) Trapezoidal Loads (pit) Vert: 1=-92-to-51=-22 16) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) lVert: 5-51=-52, 5-7=-20, 7-13=-37, 13-14=-62, 18-35=-22, 17-18=-22, 16-44=-22,29-32=-92, 22-29=-92, 21-22=-92, 4-8=-10 Horz: 1-5=-O, 7-14=15 Concentrated Loads (11b) Vert: 3=1 52 31 = , 137(F) 20=859(F) 1=142,23=142(F) 47=152 48=152 49=152 50=152 51=393 52=137(F) 53=137(F) 54=137(F) 55=137(F) 56=137(F) 57=137(F) 58=137(F) 59=137(F) 60=137(F) 61=142(F) 62=142(F) 63=142(F) Trapezoidal Loads (pit) Verl: 1=-122-to-51=-52 17) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhalb. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51=-37, 5-7=-20, 7-13=-52, 13-14=-76,18-35=-22, 17-18=-22, 16-44=-22, 29-32=-92, 22-29=-92, 21-22=-92, 4-8=-1 0 Horz: 1-5=-15, 7-14=0 Concentrated Loads (lb) Vert: 3=1 37 31 =1 37(F) 20=859(F) 1 =1 36 23=1 42(F) 47=1 37 48=1 37 49=1 37 50=1 37 51=379 52=1 37(F) 53=1 37(F) 54=1 37(F) 55=1 37(F) 56=1 37(F) 57=1 37(F) 58=137(F) 59=137(F) 60=137(F) 61=142(F) 62=142(F) 63=142(F) Trapezoidal Loads (pit) Vert: 1=-108-to-51=-37 18) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 1 st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51=-20,5-7=-39, 7-13=-39,13-14=-64,18-35=-22,17-18=-22, 16-44=-22,29-32=-92,22-29=-92,21-22=-92, 4-8=-10 Horz: 1-5=-32, 7-14=13 Concentrated Loads (lb) Vert: 3=1 20 31 =1 37(F) 20=859(F) 1 =1 29 23=1 42(F) 47=1 20 48=1 20 49=1 20 50=1 20 51 =361 52=1 37(F) 53=1 37(F) 54=1 37(F) 55=1 37(F) 56=1 37(F) 57=1 37(F) 58=1 37(F) 59=1 37(F) 60=1 37(F) 61 =1 42(F) 62=1 42(F) 63=1 42(F) Trapezoidal Loads (pit) Veit: 1=-90-to-51=-20 19) Dead + 075 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg- Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51 =-39, 5-7=-39, 7-13=-20, 13-14=-44,18-35=-22, 17-18=-22, 16-44=-22, 29-32=-92, 22-29=-92, 21-22=-92, 4-8=-10 Horz: 1-5=-1 3, 7-14=32 Concentrated Loads (11b) Vert: 3=1 39 31 =1 37(F) 20=859(F) 1 =1 37 23=1 42(F) 47=1 39 48=1 39 49=1 39 50=1 39 51 =381 52=1 37(F) 53--'l 37(F) 54=1 37(F) 55=1 37(F) 56=1 37(F) 57=1 37(F) 58=137(F) 59=137(F) 60=137(F) 61=142(F) 62=142(F) 63=142(F) Trapezoidal Loads (Pit) Vert: I =- 11 0-to-51 =-39 20) 1st Dead + Roof Live (unbalanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 5-51=-62,5-7=-62, 7-13=-22, 13-14=-47, 18-35=-22, 17-18=-22, 16-44=-22,22-32=-32, 21-22=-32, 4-8=-10 Concentrated Loads (11b) Vert: 3=-499 31 =-626(F) 20=-3294(F) 1 =-534 23=-630(F) 47=-499 48=-499 49=-499 50=-499 51 =-2027 52=-626(F) 53=-626(F) 54=-626(F) 55=-626(F) 56=-626(F) 57=-626(F) 58=-626(F) 59=-626(F) 60=-626(F) 61 =-630(F) 62=-630(F) 63=-630(F) Trapezoidal Loads (pit) Vert: 1=-132-to-51=-62 21) 2nd Dead + Roof Live (unbalanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 5-51=-22, 5-7=-62, 7-13=-62, 13-14=-87, 18-35=-22, 17-18=-22, 16-44=-22, 22-32=-32, 21-22=-32, 4-8=-10 Concentrated Loads (1b) Vert: 3=-539 31 =-626(F) 20=-3294(F) 1 =-549 23=-630(F) 47=-539 48=-539 49=-539 50=-539 51 =-2067 52=-626(F) 53=-626(F) 54=-626(F) 55=-626(F) 56=-626(F) 57=-626(F) 58=-626(F) 59=-626(F) 60=-626(F) 61 =-630(F) 62=-630(F) 63=-630(F) Trapezoidal Loads (pit) Vert: 1=-92-to-51=-22 22) 3rd Dead + 0.75 Roof Live (unbalanced) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor: Lumber Increase=1.25, Plate lncrease 1.25 Uniform Loads (pit) Vert: 5-51=-52, 5-7=-52, 7-13=-22, 13-14=-47, 18-35=-22, 17-18=-22, 16-44=-22, 29-32=-92, 22-29=-92, 21-22=-92, 4-8=-10 Concentrated Loads (lb) Vert: 3=-435 31 =-518(F) 20=-3007(F) 1 =-464 23=-520(F) 47=-435 48=-435 49=-435 50=-435 51 =-1 770 52=-518(F) 53=-518(F) 54=-518(F) 55=-518(F) 56=-518(F) 57=-518(F) 58=-518(F) 59=-518(F) 60=-518(F) 61 =-520(F) 62=-520(F) 63=-520(F) Trapezoidal Loads (pit) Vert: 1=-122-to-51=-52 WARNING- Verify d..Iqnparalneters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MII-7473 rev. 1010312015BEFORE USE. Design valid for use only with MileV8 connectors. lhis design is based only upon parameters shown. and is for an Individual building component, nor a truss system. Before use, the building designer must verify the aWlicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of inclividual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal injury and property clarnage. For general guidance regarding [he fabilcation, storage. delivery, erection and bfacing of tnisses and FILMS Systems, Se-eANSLIM11 Quality CrillediM DSB-89 and BCSI Sulding Component 6904 Parke East Blvd. Safety Informatlarlavailalble from Truss Plate Institute. 218 N. Lee Street, Suite 312, Nexcinclita, VA 22,314. Tampa, FL 33610 Job Truss Truss Type Qty Ply T14165135 744031 A03G ATTIC 1 5 Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 8.130 s mar 11 2018 mi i eK industries, Inc. vvea may ju M21:ZJb 2U1b Page :) ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-YoHFkIJSYPgW6pjtawG704piGYzuzkWassGyqjzBOt- LOAD CASE(S) Standard 3) 4th Dead + 0.75 Roof Live (unbalanced) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor: Lumber lncrease=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 5-51 =-22, 5-7=-52, 7-13=-52, 13-14=-77, 18-35=-22, 17-18=-22, 16-44=-22, 29-32=-92, 22-29=-92, 21-22=-92, 4-8=-1 0 Concentrated Loads (lb) Vert: 3=-465 31 =-518(F) 20=-3007(F) 1 =-475 23=-520(F) 47=-465 48=-465 49=-465 50=-465 51 =-1800 52=-518(F) 53=-518(F) 54=-518(F) 55=-518(F) 56=-51 8(F) 57=-518(F) 58=-518(F) 59=-518(F) 60=-518(F) 61=-520(F) 62=-520(F) 63=-520(F) Trapezoidal Loads (plf) Vert: 1--92-to-51=-22 24) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-51=6, 5-7=48, 7-13=25, 13-14=12, 18-35=-12, 17-18=-12, 16-44=-12, 22-32=-18, 21-22=-18, 4-8=-6 Horz: 1-5=-18, 7-14=37 Concentrated Loads (lb) Vert: 3=-248 31=-30(F) , 20=-1 641 (F) 1 =-242 23=-25(F) 47=-248 48=-248 49=-248 50=-248 51 =-927,52=-30(F) 53=-30(F) 54=-30(F) 55=-30(F) 56=-30(F) 57=-30(F) 58=-30(F) 59=-30(F) 60=-30(F) 61 =-25(F) 62=-25(F) 63=-25(F) Trapezoidal Loads (plf) Vert: 1=-64-to-51=6 25) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51=25, 5-7=48, 7-13=6, 13-14=-7, 18-35=-12, 17-18=-12, 16-44=-12, 22-32=-18, 21-22=-18, 4-8=-6 Horz: 1-5=-37. 7-14=18 Concentrated Loads (1b) Vert: 3=-267 31 =-30(F) 20=-1 641 (F) 1 =-250 23=-25(F) 47=-267 48=-267 49=-267 50=-267 51 =-946 52=-30(F) 53=-30(F) 54=-30(F) 55=-30(F) 56=-30(F) 57=-30(F) 58=-30(F) 59=-30(F) 60=-30(F) 61 =-25(F) 62=-25(F) 63=-25(F) Trapezoidal Loads (pit) Vert: 1 =-45-to-51 =25 26) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Veil: 5-51=-21, 5-7=21, 7-13=-2,13-14=-27, 18-35=-22,17-18=-22,16-44=-22, 22-32=-32, 21-22=-32, 4-8=-10 Horz: 1-5=-1, 7-14=20 Concentrated Loads (lb) Vert: 3=-220 31=-20(F) 20=-1631 (F) 1=-230 23=-15(F) 47=-220 48=-220 49=-220 50=-220 51=-900 52=-20(F) 53=-20(F) 54=-20(F) 55=-20(F) 56=-20(F) 57=-20(F) 58=-20(F) 59=-20(F) 60=-20(F) 61 =-1 5(F) 62=-1 5(F) 63=-1 5(F) Trapezoidal Loads (plf) Vert: 1 =-92-to-51 =-21 27) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pif) Vert: 5-51 =-2, 5-7=21, 7-13=-21, 13-14=-46, 18-35=-22, 17-18=-22, 16-44=-22, 22-32=-32, 21-22=-32, 4-8=-1 0 Horz: 1-5=-20, 7-14=1 Concentrated Loads (lb) Vert: 3=-239 31 =-20(F) 20=-1 631 (F) 1 =-238 23=-1 5(F) 47=-239 48=-239 49=-239 50=-239 51 =-919 52=-20(F) 53=-20(F) 54=-20(F) 55=-20(F) 56=-20(F) 57=-20(F) 58=-20(F) 59=-20(F) 60=-20(F) 61 =-1 5(F) 62=-1 5(F) 63=-1 5(F) Trapezoidal Loads (plf) Vert: 1=-73-lo-51=-2 28) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-51 =48, 5-7=22, 7-13=22, 13-14=9,18-35=-1 2, 17-18=-1 2, 16-44=-1 2, 22-32=-1 8, 21-22=-1 8, 4-8=-6 Horz: 1-5=-60, 7-14=34 Concentrated Loads (lb) Vert: 3=-290 31 =-30(F) 20=-1 641 (F) 1 =-259 23=-25(F) 47=-290 48=-290 49=-290 50=-290 51 =-970 52=-30fl 53=-30(F) 54=-30(F) 55=-30(F) 56=-30(F) 57=-30(F) 58=-30(F) 59=-30(F) 60=-30(F) 61 =-25(F) 62=-25(F) 63=-25(F) Trapezoidal Loads (pit) Vert: 1=-22-to-51=48 29) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Inctease=1.60, Plate Incfease=1.60 Uniform Loads (pit) Vert: 5-51=22, 5-7=22, 7-13=48, 13-14=35, 18-35=-12, 17-18=-12, 16-44=-12, 22-32=-18, 21-22=-18, 4-8=-6 Horz: 1-5=-34, 7-14=60 Concentrated Loads (lb) Vert: 3=-264 31 =-30(F) 20=-1 641 (F) 1 =-249 23=-25(F) 47=-264 48=-264 49=-264 50=-264 51 =-943 52=-30(F) 53=-30(F) 54=-30(F) 55=-30(F) 56=-30(F) 57=-30(F) 58=-30(F) 59=-30(F) 60=-30(F) 61 =-25(F) 62=-25(F) 63=-25(F) Trapezoidal Loads (plf) Vert: 1 =-48-to-51 =22 30) Reversal: Dead +.0.6 MWFRS Wind (Pos. Internal) 3rd Parallel: Lumber ncrease=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51=48, 5-7=22, 7-13=22, 13-14=9, 18-35=-12, 17-18=-12, 16-44=-12, 22-32=-18, 21-22=-18, 4-8=-6 Harz: 1-5=-60, 7-14=34 Concentrated Loads (lb) Vert: 3=-290 31=-30(F) 20=-1641(F) 1=-259 23=-25(F) 47=-290 48=-290 49=-290 50=-290 51=-970 52=-30(F) 53=-30(F) 54=-30(F) 55=-30(F) 56=-30(F) 57=-30(F) 58=-30(F) 59=-30(F) 60=-30(F) 61=-25(F) 62=-25(F) 63=-25(F) Trapezoidal Loads (plf) Vert: 1=-22-to-51=48 31) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 4th Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51=22,5-7=22, 7-13=48,13-14=35,18-35=-12, 17-18=-12,16-44=-12,22-32=-18,21-22=-18, 4-8=-6 Horz: 1-5=-34, 7-14=60 nntimirwi nn nqnp. WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MfTEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MilekO connectors. This design is based only upon pxamelers shown. and is for an individual building component. not 0 IMSS SySleln. Before use, the building designer must vedfy the applicability of design parameters and properly Incorporate this design Into the overall individual Iruss members only. Additional temporary and permanent bracing MiTek' building design. Bracing Indicated Is to prevent buckling of web and/or chord is always required for stability and to prevent collapsevAlh possible personal injury and property damage. for general guidance regarding the 6904 Parke East Blvd. fabrication, storage. delivery. erection and bracing of trusses and truss systems. seeAAMMII Quaffly Ciffaft DSB-89 and BCSIBufldhug Component Tamp", FL 33610SafetykdonnatioriavallaNefromTrussPlaleInstitute. 218 N. Lee Street-Sulle 312, Alexandria, VA 22314. Job Truss Truss Type City Ply T14165135 744031 A03G ATTIC 1 5 Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 8.130 s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:21:35 2018 Page 6 ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-YoHFkIJSYPgW6pjtawG704p1 GYzuzkWassGyqjzBOf- LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=-264 31=-30(F) 20=-1641(F) 1=-249 23=-25(F) 47=-264 48=-264 49=-264 50=-264 51=-943 52=-30(F) 53=-30(F) 54=-30(F) 55=-30(F) 56=-30(F) 57=-30(F) 58=-30(F) 59=-30(F) 60=-30(F) 61 =-25(F) 62=-25(F) 63=-25(F) Trapezoidal Loads (pit) I Vert: 1 =-48-to-51 =22 32) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal) 1 st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51 =21, 5-7=-5, 7-13=-5, 13-14=-30, 18-35=-22, 17-18=-22, 16-44=-22, 22-32=-32, 21-22=-32, 4-8=-1 0 Horz: 1-5=-43, 7-14=1 7 Concentrated Loads (lb) Vert: 3=-263 31=-20(F) 20=-1631(F) 1=-247 23=-15(F) 47=-263 48=-263 49=-263 50=-263 51=-942 52=-20(F) 53=-20(F) 54=-20(F) 55=-20(F) 56=-20(F) 57=-20(F) 58=-20(F) 59=-20(F) 60=-20(F) 61 =-1 5(F) 62=-1 5(F) 63=-1 5(F) Trapezoidal Loads (pit) Vert: 1=-49-to-51=21 33) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51=-5, 5-7=-5, 7-13=21, 13-14=-4, 18-35=-22, 17-18=-22, 16-44=-22, 22-32=-32, 21-22=-32, 4-8=-10 Horz: 1-5=-17. 7-14=43 Concentrated Loads (lb) Vert: 3=-237 31 =-20(F) 20=-1 631 (F) 1 =-237 23=-1 5(F) 47=-237 48=-237 49=-237 50=-237 51 =-916 52=-20(F) 53=-20(F) 54=-20(F) 55=-20(F) 56=-20(F) 57=-26(F) 58=-20(F) 59=-20(F) 60=-20(F) 61 =-1 5(F) 62=-1 5(F) 63=- 1 5(F) Trapezoidal Loads (pit) Vert: 1 =-75-to-51 =-5 34) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75 Uninhalb. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber lncrease=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51=-52, 5-7=-20, 7-13=-37,13-14=-62,18-35=-22,17-1 8=-22, 16-44=-22, 29-32=-92, 22-29=-92, 21-22=-92, 4-8=-1 0 Horz: 1-5=-O, 7-14=15 Concentrated Loads (lb) Vert: 3=-362 31 =-306(F) 20=-2435(F) 1 =-391 23=-305(F) 47=-362 48=-362 49=-362 50=-362 51 =-I 379 52=-306(F) 53=-306(F) 54=-306(F) 55=-306(F) 56=-306(F) 57=-306(F) 58=-306(F) 59=-306(F) 60=-306(F) 61=-305(F) 62=-305(F) 63=-305(F) Trapezoidal Loads (pit) Vert: 1=-122-to-51=-52 35) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Right); Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51 =-37, 5-7=-20, 7-13=-52, 13-14=-76, 18-35=-22, 17-18=-22, 16-44=-22, 29-32=-92, 22-29=-92, 21-22=-92, 4-8=- 10 Horz: 1-5=-15, 7-14=0 Concentrated Loads (1b) Vert: 3=-376 31 =-306(F) 20=-2435(F) 1 =-396 23=-305(F) 47=-376 48=-376 49=-376 50=-376 51 =-1 393 52=-306(F) 53=-306(F) 54=-306(F) 55=-306(F) 56=-306(F) 57=-306(F) 58=-306(F) 59=-306(F) 60=-306(F) 61=-305(F) 62=-305(F) 63=-305(F) Trapezoidal Loads (pit) Vert: 1=-108-to-51=-37 36) Reversal: Dead+0.75 RoofLive (bal.)+0.75 Uninhab. Attic Storage+ 0.75 Attic Floor+0.75(0.6 MWFRSWind(Neg. Int) Ist Parallel): Lumber Increase= 1 .60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51 =-20, 5-7=-39, 7-13=-39, 13-14=-64,18-35=-22, 17-18=-22, 16-44=-22, 29-32=-92, 22-29=-92, 21-22=-92, 4-8=-10 Horz: 1-5=-32, 7-14=1 3 Concentrated Loads (lb) Vert: 3=-394 31 =-306(F) 20=-2435(F) 1 =-403 23=-305(F) 47=-394 48=-394 49=-394 50=-394 51 =-1 411 52=-306(F) 53=-306(F) 54=-306(F) 55=-306(F) 56=-306(F) 57=-306(F) 58=-306(F) 59=-306(F) 60=-306(F) 61 =-305(F) 62=-305(F) 63=-305(F) Trapezoidal Loads (pit.) Vert: 1 =-90-to-51 =-20 37) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-51 =-39, 5-7=-39, 7-13=-20, 13-14=44,18-35=-22,17-18=-22, 16-44=-22, 29-32=-92, 22-29=-92, 21-22=-92, 4-8=-10 Horz: 1-5=-13, 7-14=32 Concentrated Loads (lb) Vert: 3=-374 31 =-306(F) 20=-2435(F) 1 =-395 23=-305(F) 47=-374 48=-374 49=-374 50=-374 51 =-1 391 52=-306(F) 53=-306(F) 54=-306(F) 55=-306(F) 56=-306(F) 57=-306(F) 58=-306(F) 59=-306(F) 60=-306(F) 61 =-305(F) 62=-305(F) 63=-305(F) Trapezoidal Loads (pit) Vert: 1 =-1 1 0-to-51 =-39 WARNING -Verify design parameters and READ AfOrES ON -rHIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE - Design valid for use only with Milek(D connectors. This design Is based only upon paramelers, shown, and is for an individual LKillding component not a truss system. Before use, the building designer inust verify the applicability of design parameters and properly incorporate this design into the overall building design. Brming indicated Is to prevent buckling of Individual truss web and/or chord members only. Addilional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. for general guidance regarding the fabilcallon, storage, delivery, erection and bracing of trumes and IRms systems. seeANSMI1 Quality CrUedo, DSB-89 and SCSI Sufldblig Component 6904 Parke East Blvd. Safety Intonnallowivailable from TFUMS Plate. Institute. 218 N. Lee Street, Sulte 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Oty Ply T14165136 744031 A04G ATTIC 1 4 Job Reference (optional) American Buiiciers Suppiy, Winier Haven, FL 33880 8- 130 s Mar H 20 18 MiTek indublije6, inu. Vved May 30 06:21:41 2018 rdyu I ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-NxeW-LOD8FQgqkAOxANXGL3OPz1 sNOHSEnjG1 NzBOeu 14-11-4 1 6-W-j 2gl 61%4 1 2'6-610'-4 2-f 1- IF L6-6-1) L2-6-0 48-6-,0 4 1-4 2 2 a DO NOT APPLY BOLTS IN THIS SECTION OF 6.00 F1 _2 5x6 2x4 11 5x6 Scale 1: 116.3 THE TOP CHORD 5 6 7Special3x4 jx43x4Special 8 3x6 -Z 8 3x6 Special 4x6 5:w A-rA T1 U 4x4 5- 2pecra4x4 ' _422 Special 4x6 z- 33323433 Special 2i 3xi 0 11 6x10 11 . 3x10 11 9 10 7 41 5x10 -5- 40 3x8 I I x6 )I 3x6 c? ZLUS24tt1,g 39 i4x6l14-0-0 1212 j3- 44 45 46 47 48 27 4 3 2450 2 2 11 53 54 55 56 Ll 15 1429282521LUS241716 5x84x6 1.5x8 STP 5x14 4x4-,-, WO 11 1.5x8 STP 3x6 i I x 3x6 I I 3x8 I I LUS24 LUS24 LUS24 7xl 4 MT20HS = 7x8 10x10 4x10 HUS26 LUS24 LUS24 LUS24 4x4 = 7xl 4 MT20HS LUS24 7x6 = 7xl 4 MT20HS 4xiO 11 LUS24 7x-14 MT20HS HUS26 LUS24 HUS26 HHUS28-2 417'_4_21i14 A -2-0 2LI)-, -12 36-6-40 k2-.O L8 2-44 11 22 1ft-1 1 70 %.0 7_ 2 3-10-7 2-(" P I ate Offset s (X,Y) - - [5:0-3-0,0 -2-0], [7:0-3-0,0-2-0], [9:0-3-0, E dg e], 112:0-4-0,0-1 -15], [115:0- 5-0,0-6-01, [18:0- 3-12,0-3-8], [19: 0 -7-0 , 0- 1 -8] , [2 1 0-3-0, 0-4 - 12] , [2 2 0-7-0 , 0-2 - 0] , 124:0-7-0,012 0], 129:0-4-4,0-0-14] LOADING (pst) SPACING- 2-0-0 CS11. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.95 Veri(LL) -0.64 20 >684 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.69 Vert(CT) -1.05 20 >413 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horz(CT) 0.14 12 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Wind(ILL) 0.56 20 >779 240 Weighti 1770 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x6 SP No.2 *Except* TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, 5-7: 2x4 SP No.2, 9-13: 2x4 SP M 30 except end verticals. BOTCHORD 2x6 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 18-26: 2x4 SP M 31, 15-17.12-15: 2x8 SP No.2 JOINTS 1 Brace at Jt(s): 32. 33, 34, 24 18-26: 2x6 SP 240OF 2.OE WEBS 2x4 SP No.3 *Except* 4-34,8-34: 2x6 SP 240OF 2.OE, 1-29: 2x8 SP No.2 1-28,15-18,26-28: 2x4 SP No.2 REACTIONS. (lb/size) 29=13635/0-8-0, 15=1247/0-8-0, 12=6421/0-3-0 Max Horz 29=-403(LC 9) Max Uplift 29=-4078(LC 8), 15=-1676(LC 9), 12=-1741 (LC 5) Max Grav 29=1 3635(LC 1), 15=1 432(LC 21), 12=6421 LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-15544/4745, 2-4=-16439/5237, 4-5=-5826/1929, 5-6=-5394/1817, 6-7=-5394/1817, 7-8=-6133/2045,8-10=-15408/5039,10-11=-13105/3588,11-12=-12852/3473, 1-29=-12778/3851 BOTCHORD 28-29=-324/754, 25-28=-1491/4564, 23-25=-1453/4887, 21-23=-1852/6657, 24-26=-3078/10242 22-24=-2798/8542, 19-22=-4361/14113, 18-19=-4361/14113, 15-16=-74/283; 14-15=-3019/11458,12-14=-3019/11458 WEBS 2-28=-353811151, 2-26=-348/734, 25-26=-892/3340, 26-30=-1 274/4806, 18-31 =-1 859/5655, 4-30=-8825/3145, 30-32=-8930/3173, 32-34=-8764/3129, 33-34=-8764/3129, 31-33=-8993/3197, 8-31=-8852/3151, 1-28=-4154/13568, 10-15=-2599/1908, 10-18=-1800/3084, 15-18=-2988/11510,11-15=-330/428, 11-14=-402M2, 26-28=-2813/9316, 5-32=-685/2286, 7-33=-993/3224, 6-34=-439/289, 21-22=-7976/2219 NOTES- 1) 4-ply truss to be connected together with 10d (0.131"x3") nails as follows:, Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc, 2x4 - 1 row at 0-6-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 31-16 2x4 - 1 row at 0-7-0 oc, 2X6 - 2 rows staggered at 0-9-0 Joaquin Velez PE No.681182 oc. MiTek USA, Inc. FIL Cert 6634 Attach TC w/ 1/2" diam. bolts (ASTM A-307) in the center of the member w/washers at 4-0-0 oc. 6904 Parke East Blvd. Tampa FL 33610 Attach BC w/ 1/2" diam. bolts (ASTM A-307) in the center of the member w/washers at 4-0-0 oc. Date: 2) All loads are considered equally applied to all plies, except it noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. May 30,2018 MA 00 oft t 1 Irgiveloadshavebeenconsideredfo WARNING- Verify design Parameters and READ NOTES OAf-rHISAIVDlAtCLUDEDMrrEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekG conneclots, Ihis design is based only upon parameters shown. and Is for an Individual building component, not a truss syslen). Before use, the building designei must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord rnembers only. Additional temporary and permanent bracing MiTek' Is always required foi stability and to pievent collapse with possible personal Injury and property darnage. For general guidance regarding the fabricatiom storage, delivery. erection and bracing of trusses and truss systems, weANSVl?11 Quailly Cf"da, DSO-89 and BCS1 Bugdbg Component 6904 Parke East Blvd. Safety Ilinformatilonavallable from Truss Plate Institute. 218 N. Lee Street, Suite 312, PJexandrla, VA 22314. Tampa, FIL 33610 Job Truss Truss Type QtY Ply T14165136 744031 A04G ATTIC 1 4 Job Reference (optional) American Builders Supply, Winter Haven, I-L 33880 b.iiu s tvar 1 1 eUl d M1 I eK maUSITIe5, InU. vveu ivray 5u uo:e j.4 i Zu 10 rdye e ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-NxeW-LOD8FQgqkAOxANXGL3OPzlsNOHSEnjGlNzBOeu NOTES- 4) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TGDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11, Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone; cantilever right exposed ; porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water poncling. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0pst on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Ceiling dead load (5.0 psf) on member(s). 4-30, 30-32, 32-34, 33-34, 31-33, 8-31 10) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 24-26, 22-24, 19-22, 18-19 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4078 lb uplift at joint 29, 1676 lb uplift at joint 15 and 1741 Ito uplift at joint 12. 12) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 13) Use Simpson Strong -Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 16-0-0 oc max. starting at 2-0-12 from the left end to 20-2-0 to connect truss(es) to back face of bottom chord. 14) Use Simpson Strong -Tie LUS24 (4-10d Girder, 2-10d Truss, Single Ply Girder) or equivalent spaced at 6-0-0 oc max. starting at 4-0-12 from the left end to 28-0-12 to connect truss(es) to back face of bottom chord. 15) Use Simpson Strong -Tie HHUS28-2 (22-10d Girder, 8-10d Truss, Single Ply Girder) or equivalent at 28-10-0 from the left end to connect truss(es) to back face.of bottom chord. 16) Fill all nail holes where hanger is in contact with lumber. 17) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 550 to down and 237 lb up at 0-3-10, 541 lb down and 246 Ito up at 2-0-12, 541 lb down and 246 lb up at 4-0-12, 541 lb down and 246 lb up at 6-0-12, 541 lb down and 246 lb up at 8-0-12, and 541 lb down and 246 lb up at 10-0-12, and 2069 lb down and 857 lb up at 12-0-12 on top chord. The design/selection of such connection device(s) is the responsibility of others. 18) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate lncrease=1.25 Uniform Loads (pit) Vert: 5-43=-60, 5-7=-60, 7-13=-60, 20-29=-20, 4-8=-10, 18-26=-30, 12-17=-20 Concentrated Loads (11b) Vert: 3=-501 (B) 27=-628(B) 1 =-535 18=-2779(B) 21 =-628(B) 39=-501 (B) 40=-501 (B) 41 =-501 (B) 42=-501 (B) 43=-2029 44=-628(B) 45=-628(B) 46=-628(B) 47=-628(B) 48=-628(B) 49=-628(B) 50=-628(B) 51=-628(B) 53=-596(B) 54=-596(B) 55=-596(6) 56=-596(B) Trapezoidal Loads (plf) Vert: 1=-132-to-43=-60 2) Dead + 0.75 Roof Live (balanced) + 0.75 Uninhab. Attic Storage + 0-75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 5-43=-50, 5-7=-50, 7-13=-50, 20-29=-20, 4-8-10, 18-26=-90, 12-17=-20 Concentrated Loads (lb) Vert: 3=-437(B) 27=-520(13) 1 =-465 18=-2539(B) 21 =-520(B) 39=-437(B) 40=-437(B) 41 =-437(B) 42=-437(B) 43=- 1772 44=-520(B) 45=-520(B) 46=-520(B) 47=-520(B) 48=-520(B) 49=-520(B) 50=-520(B) 51=-520(8) 53=-487(B) 54=-487(B) 55=-487(B) 56=-487(B) Trapezoidal Loads (jolf) Vert: 1=-122-to-43=-50 3) Dead + Uninhabitable Attic Without Storage: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) I Vert: 5-43=-20, 5-7=-20, 7-13=-20, 20-29=-40, 4-8=-10, 18-26=-30, 17-38=-40, 36-38=-40, 12-36=-40 Concentrated Loads (11b) Vert: 3=-365(B) 27=-304(B) 1 =-375 18=-2043(B) 21 =-304(B) 39=-365(B) 40=-365(B) 41 =-365(B) 42=-365(B) 43=-1 484 44=-304(B) 45=-304(B) 46=-304(B) 47=-304(B) 48=-304(B) 49=-304(B) 50=-304(B) 51=-304(B) 53=-227(B) 54=-227(B) 55=-227(B) 56=-227(B) Trapezoidal Loads (pit) Vert: 1=-92-to-43=-20 4) Dead + 0.6 MWFRS Wind (Pos- Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=6, 5-7=48, 7-12=25, 12-13=16, 20-29=-12, 4-8=-6, 18-26=-18, 15-17=-12, 12-15=17 Herz: 1-5=-18, 7-12=37, 12-13=28, 36-38=29 Concentrated Loads (lb) Vert: 3=221 (B) 27=209(B) 1 =226 18=1 522(B) 21 =209(B) 39=221 (B) 40=221 (B) 41 =221 (B) 42=221 (B) 43=832 44=209(B) 45=209(B) 46=209(B) 47=209(B) 48=209(B) 49=209(B) 50=209(B) 51 =209(B) 53=235(B) 54=235(B) 55=235(B) 56=235(B) Trapezoidal Loads (plf) Vert: 1 =-66-to-43=6 5) Dead+ 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=25, 5-7=48, 7-12=6, 12-13=26, 20-29=-12, 4-8=-6, 18-26=-18, 15-17=-12, 12-15=17 Herz: 1-5=-37, 7-12=18, 12-13=38, 36-38=29 Concentrated Loads (lb) Vert: 3=202(B) 27=209(B) 1=219 18=1522(8) 21=209(B) 39=202(B) 40=202(B) 41=202(B) 42=202(B) 43=813 44=209(B) 45=209(B) 46=209(B) 47=209(B) 48=209(B) 49=209(B) 50=209(B) 51=209(B) 53=235(B) 54=235(B) 55=235(B) 56=235(B) Trapezoidal Loads (pit) Vert: 1=-47-to-43=25 6) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=-19, 5-7=23, 7-12=-O, 12-13=8, 20-29=-20, 4-8=-10, 18-26=-30, 15-17=-20, 12-15=9 Herz: 1-5=-1, 7-12=20, 12-13=28, 36-38=29 Concentrated Loads (lb) Vert: 3=246(B) 27=217(B) 1 =237 18=1 530(B) 21 =217(B) 39=246(B) 40=246(B) 41 =246(B) 42=246(B) 43=857 44=217(B) 45=2 I 7(B) 46=217(B) 47=217(B) 48=217(B) 49=217(B) 50=217(B) 51 =217(B) 53=243(8) 54=243(B) 55=243(B) 56=243(B) Trapezoidal Loads (plf) Vert: 1=-91-to-43=-19 nntimifad nn nnnp. WARNING -Verify design Parameters and READ NOTES ON THIS AND INCLUGEOMMEKREFERANCE PAGE M11-7473rev. 1010312015 BEFORE USE. Zwd Design valid for rise only with MiTek(b conneciors. This design is based only upon parameters shown. and is foi an Individual building componenL not a truss systern. Before use, the building designer must verify the applicability of design parameters and properly incoporale this design Into the overall individual truss members only, Additional temporary and permanent bf.ing MiTek' building design. Bracing indicated Is to prevent buckling of web and/of cbofd1 Is always required for stability and to prevent collapse with posslNe personal Injury and properly darnage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, sepANS&VII QuaW Ciffeft DSB-89 and BCSI BuMdIng Component 6904 Parke East Blvd. Safety kdonnonanavoilaNe from Truss Plate. Institute, 218 N. Lee Street, Sulte 312, Alexandria. VA 22314 Tampa, FL 33610 Job Truss Truss Type Oty Ply T14165136 744031 A04G ATTIC 1 4 Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 8.130 s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:21:41 2018 Page 3 1 D:p Bo2Q DQ4UzFAgn3M5ICI GzTvbv-NxeW-LOD8FQgqkAOxANXGL3OPz 1 sN OHS Enj G 1 NzBOeu LOAD CASE(S) Standard 7) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=-O, 5-7=23, 7-12=-1 9, 12-13=-1 1, 20-29=-20, 4-8=-1 0, 18-26=-30, 15-17=-20, 12-15=9 Horz: 1-5=-20, 7-12=1, 12-13=9, 36-38=29 Concentrated Loads (lb) Vert: 3=227(B) 27=217(B) 1 =230 18=1 530(B) 21 =217(B) 39=227(B) 40=227(B) 41 =227(B) 42=227(B) 43=838 44=217(B) 45=217(B) 46=217(B) 47=217(B) 48=217(B) 49=217(B) 50=217(B) 51 =217(B) 53=243(B) 54=243(B) 55=243(B) 56=243(B) Trapezoidal Loads (pit) Vert: 1 =-72-to-43=-b 8) Dead + 0.6 MWFRS Wind (Pos. Internal) 1 st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=48, 5-7=22, 7-12=22, 12-13= 14, 20-29=-1 2, 4-8=-6, 18-26=- 18, 12-17=-1 2 Harz: 1-5=-60, 7-12=34, 12-13=26 Concentrated Loads (11b) Vert: 3=178(B) 27=209(B) 1=210 18=1522(B) 21=209(B) 39=178(8) 40=178(B) 41=178(6) 42=178(B) 43=789 44=209(6) 45=209(B) 46=209(6) 47=209(B) 48=209(B) 49=209(B) 50=209(B) 51 =209(B) 53=235(B) 54=235(6) 55=235(8) 56=235(B) Trapezoidal Loads (pit) Vert: 1=-24-to-43=48 9) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=22, 5-7=22, 7-12=48, 12-13=40, 20-29=-1 2, 4-8=-6, 18-26=-1 8, 12-17=-1 2 Harz: 1-5=-34, 7-12=60, 12-13=52 Concentrated Loads (lb) Vert: 3=204(B) 27=209(B) 1 =220 18=1 522(6) 21 =209(B) 39=204(B) 40=204(B) 41 =204(B) 42=204(B) 43=816 44=209(B) 45=209(B) 46=209(B) 47=209(B) 48=209(B) 49=209(B) 50=209(B) 51=209(B) 53=235(B) 54=235(B) 55=235(B) 56=235(B) Trapezoidal Loads (pit) Vert: 1=-50-to-43=22 10) Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=48,5-7=22, 7-12=22,12-13=14,20-29=-12, 4-8=-6,18-26=-18,12-17=-12 Horz: 1-5=-60, 7-12=34, 12-13=26 Concentrated Loads (lb) Vert: 3=178(B) 27=209(B) 1=210 18=1522(B) 21=209(B) 39=178(B) 40=178(B) 41=178(B) 42=178(B) 43=789 44=209(B) 45=209(B) 46=209(B) 47=209(B) 48=209(B) 49=209(B) 50=209(B) 51 =209(B) 53=235(B) 54=235(B) 55=235(B) 56=235(B) Trapezoidal Loads (plf) Vert: 1=-24-to-43=48 11) Dead + 0.6 MWFRS Wind (Pos. Internal) 4th Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=22, 5-7=22, 7-12=48, 12-13=40, 20-29=-1 2, 4-8=-6, 18-26=-1 8, 12-17=-1 2 Horz: 1-5=-34, 7-12=60, 12-13=52 Concentrated Loads (11b) Vert: 3=204(B) 27=209(B) 1 =220 18=1 522(B) 21 =209(B) 39=204(B) 40=204(B) 41 =204(B) 42=204(B) 43=816 44=209(B) 45=209(B) 46=209(B) 47=209(B) 48=209(B) 49=209(B) 50=209(B) 51 =209(B) 53=235(B) 54=235(B) 55=235(B) 56=235(B) Trapezoidal Loads (pif) Vert: 1=-50-to-43=22 12) Dead + 0.6 MW FRS Wind (Neg..Internal) 1 st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=23, 5-7=-3, 7-12=-3, 12-13=6, 20-29=-20, 4-8=-1 0, 18-26=-30, 12-17=-20 Horz: 1-5=-43, 7-12=17,12-13=26 Concentrated Loads (lb) Vert: 3=204(B) 27=217(B) 1 =221 1 8=1 530(B) 21 =217(B) 39=204(B) 40=204(B) 41 =204(B) 42=204(B) 43=81 5 44=217(B) 45=217(B) 46=217(6) 47=217(B) 48=217(B) 49=217(B) 50=217(B) 51 =217(B) 53=243(B) 54=243(B) 55=243(B) 56=243(B) Trapezoidal Loads (pit) Vert: 1=-49-to-43=23 13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=-3,5-7=-3, 7-12=23,12-13=32,20-29=-20, 4-8=-10, 18-26=-30, 12-17=-20 Horz: 1-5=-17, 7-12=43,12-13=52 Concentrated Loads (lb) Vert: 3=230(B) 27=217(B) 1=231 18=1530(6) 21=217(B) 39=230(B) 40=230(B) 41=230(B) 42=230(B) 43=841 44=217(B) 45=217(B) 46=217(B) 47=217(B) 48=217(B) 49=217(B) 50=217(B) 51=217(B) 53=243(B) 54=243(B) 55 243(13) 56=243(B) Trapezoidal Loads (pit) Vert: 1=-75-to-43=-3 14) Dead + Uninhab. Attic Storage + Attic Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (pit) Vert.: 5-43=-20, 5-7=-20, 7-13=-20, 20-29=-20, 4-8=- 10, 18-26=-1 10, 12-17=-20 Concentrated Loads (lb) Vert: 3=-246(B) 27=-1 96(B) 1 =-256 18=-1 517(B) 21 =-1 96(B) 39=-246(B) 40=-246(B) 41 =-246(B) 42=-246(B) 43=-1 000 44=-196(B) 45=-196(B) 46=-196(B) 47=-196(B) 48=-196(B) 49=-196(B) 50=-196(B) 51=-196(B) 53=-158(B) 54=-158(B). 55=-158(B) 56=-158(B) Trapezoidal Loads (pit) Vert: 1=-92-to-43=-20 15) Dead + Uninhabitable Attic Storage: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (pit) Vert: 5-43=-20,5-7=-20, 7-13=-20,20-29=-20, 4-8=-10, 18-26=-1 10, 12-17=-20 ContinnPri on r),qne A WARNING- Verify design Parameters and READ NOTES ON THIS AND INCLUDED MrFEK REFERANCE PAGE Mll-7473 rev. 1010312016 BEFORE USE. Design valid for rise only with Mllek@ connectors. This design Is based only upon parameters shown, and is for anindividual building component. not log" a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and peu-narreni brcy-Ing MiTek' is always required for -stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding [he fabrication. storage. delivery, erection and bracing of Irtmes and truss systems. seeANSUMIJ Quaffly Ciftfla, DSO-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Informatlotrivailable from TFUss Plate Institute, 218 N. Lee Street. Suite 312, Nexandria, VA 22,314. Tarnpa, FL 33610 Job Truss Truss Type Qty , Ply T14165136 744031 A04G ATTIC 1 4 Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 8.130 s mar 11 20113 mt I eK inaustries, Inc. vVea may ju ub:2-l:4i zui t3 Fage 4 ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-NxeW-LOD8FQgqkAOxANXGL3OPzlsNOHSEnjG1 NzBOeu LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=-246(B) 27=-196(B) 1=-256 18=-1517(B) 21=-196(B) 39=-246(B) 40=-246(B) 41=-246(B) 42=-246(B) 43=-1000 44=-196(B) 45=-196(B) 46=-196(B) 47=-196(B) 48=-196(B) 49=-196(B) 50=-196(B) 51=-196(B) 53=-158(B) 54=-158(B) 55=-158(B) 56=-158(B) Trapezoidal Loads (plf) Vert: 1=-92-to-43=-20 16) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=-50,5-7=-18, 7-12=-35,12-13=-29,20-29=-20, 4-8=-10, 18-26=-90, 15-17=-20, 12-15=2 Horz: 1-5=-O, 7-12=15, 12-13=21, 36-38=22 Concentrated Loads (lb) Vert: 3=150(B) 27=135(8) 1=141 18=761(B) 21=135(B) 39=150(B) 40=150(B) 41=150(B) 42=150(B) 43=391 44=135(B) 45=135(B) 46=135(B) 47=135(B) 48=135(B) 49=135(B) 50=135(B) 51=135(B) 53=160(B) 54=160(B) 55=160(B) 56=160(B) Trapezoidal Loads (pif) Vert: 1=-122-to-43=-50 17) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhalb. Attic Storage + 0.75 Attic Floor + 0-75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=-35,5-7=-18, 7-12=-50,12-13=-43, 20-29=-20, 4-8=-10, 18-26=-90,15-17=-20, 12-15=2 Horz: 1-5=-1 5, 7-12=0, 12-13=7, 36-38=22 Concentrated Loads (lb) Veil: 3=1 35(B) 27=1 35(B) 1 =1 35 18=761 (B) 21 =1 35(B) 39=135(B) 40=1 35(B) 41 =1 35(B) 42=135(B) 43=377 44=1 35(B) 45=1 35(B) 46=1 35(B) 47=1 35(B) 48=1 35(B) 49=1 35(B) 50=1 35(B) 51 =1 35(B) 53=1 60(B) 54=1 60(8) 55=1 60(B) 56=1 60(B) Trapezoidal Loads (pif) Vert: 1=-107-to-43=-35 18) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=-1 8, 5-7=-37, 7-12=-37, 12-13=-31, 20-29=-20, 4-8=-1 0, 18-26=-90, 12-17=-20 Horz: 1-5=-32, 7-12=1 3,12-13=1 9 Concentrated Loads (lb) Vert: 3=1 1 B(B) 27=1 35(B) 1 =1 28 18=761 (B) 21 =1 35(B) 39=1 18(B) 40=1 18(B) 41 =1 1 B(B) 42=1 18(B) 43=359 44=1 35(B) 45=1 35(B) 46=1 35(B) 47=1 35(B) 48=135(B) 49=135(B) 50=135(B) 51=135(B) 53=160(B) 54=160(B) 55=160(B) 56=160(B) Trapezoidal Loads (pit) Vert: 1=-90-to-43=-18 19) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber lncrease=1.60 Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=-37, 5-7=-37, 7-12=-18,12-13=-1 1, 20-29=-20, 4-8=-10, 18-26=-90,12-17=-20 Horz: 1-5=- 13, 7-12=32, 12-13=39 Concentrated Loads (lb) Vert: 3=1 37(B) 27=1 35(B) 1 =1 36 18=761 (B) 21 =1 35(B) 39=1 37(B) 40=1 37(B) 41 =1 37(B) 42=1 37(B) 43=379 44=1 35(B) 45=1 35(B) 46=1 35(B) 47=1 35(B) 48=135(B) 49=135(B) 50=135(B) 51=135(B) 53=160(B) 54=160(B) 55=160(B) 56=160(B) Trapezoidal Loads (plf) I Vert: 1=-1b9-to-43=-37 20) 1st Dead + Roof Live (unbalanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 5-43=-60,5-7=-60,7-13=-20,20-29=-20, 4-8=-10, 18-26=-30,12-17=-20 Concentrated Loads (lb) Vert: 3=-501 (B) 27=-628(B) 1 =-535 18=-2779(B) 21 =-628(B) 39=-501 (B) 40=-501 (B) 41 =-501 (B) 42=-501 (B) 43=-2029 44=-628(B) 45=-628(B) 46=-628(B) 47=-628(B) 48=-628(B) 49=-628(B) 50=-628(B) 51 =-628(6) 53=-596(B) 54=-596(B) 55=-596(B) 56=-596(6) Trapezoidal Loads (pif) Vert: 1=-132-to-43=-60 21) 2nd Dead + Roof Live (unbalanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: 5-43=-20, 5-7=-60, 7-13=-60,20-29=-20, 4-8=-10, 18-26=-30, 12-17=-20 Concentrated Loads (Ilb) Vert: 3=-541 (B) 27=-628(B) 1 =-550 18=-2779(8) 21 =-628(B) 39=-541 (B) 40=-541 (B) 41 =-541 (B) 42=-541 (B) 43=-2069 44=-628(B) 45=-628(B) 46=-628(B) 47=-628(B) 48=-628(B) 49=-628(B) 50=-628(B) 51 =-628(B) 53=-596(B) 54=-596(B) 55=-596(8) 56=-596(B) Trapezoidal Loads (pit) Vert: 1=-92-to-43=-20 22) 3rd Dead + 0.75 Roof Live (unbalanced) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pif) Vert: 5-43=-50, 5-7=-50, 7-13=-20, 20-29=-20, 4-8=- 10, 18-26=-90, 12-17=-20 Concentrated Loads (lb) Vert: 3=-437(B) 27=-520(B) 1 =-465 18=-2539(B) 21 =-520(B) 39=-437(B) 40=-437(B) 41 =-437(B) 42=-437(B) 43=-1 772 44=-520(B) 45=-520(B) 46=-520(B) 47=-520(B) 48=-520(B) 49=-520(B) 50=-520(B) 51 =-520(B) 53=-487(B) 54=-487(B) 55=-487(B) 56=-487(B) Trapezoidal Loads (plf) Vert: 1=-122-to-43=-50 23) 4th Dead + 0.75 Roof Live (unbalanced) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 5-43=-20, 5-7=-50, 7-13=-50, 20-29=-20, 4-8=-10, 18-26=-90,12-17=-20 nntinued an n ine WARNING - Verify design paraineters and REAO NOTES ON THIS AND INCLUOED MfTEKREFERANCE PAGE M11-7473 rev. 10103,12015 BEFORE USE. Design valid for use only with MITek6 connectors. This design is based only upon parameters shown, and is for an individual building cornponent. not a firm system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design Into the overall Bracing Indcaled is to buckling individual Ifuss web and/or chord mernbers only. Addilional temporary and permanent bfacing MiTek' building, d"gn. prevent of is always required for stability arid to prevent collapse with poAble personal injury and properly damage. for general guidance regarding the 6904 Parke East Blvd. fabrication, storage. delivery. ere<,.tion and bracing of liusses and truss systems. seeANSMI1 QualMy Cifferld, DS849 and BCSF BuIldbig Component Tampa, Fl- 33610SafetybtformufforiavallablefromTIMsPlateInstitute. 218 N. Lee Street, Suite. 312, Mexarrdria, VA 22,314. Job Truss Truss Type Oty , Ply T14165136 744031 A04G ATTIC 1 4 Job Reference optional) American Builders Supply, Winter Haven, FL 33880 8.130 s Mar 11 2018 Mi I ek I ndustnes, I nc- Wed May 30 06:21:41 2018 Vage b ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-NxeW-LOD8FQgqkAOxANXGL3OPz1 sNOHSEnjGl NzBOeu LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=-467(B) 27=-520(B) 1 =-476 18=-2539(B) 21 =-520(B) 39=-467(B) 40=-467(B) 41 =-467(B) 42=-467(B) 43=- 1802 44=-520(B) 45=-520(B) 46=-520(B) 47=-520(B) 48=-520(B) 49=-520(B) 50=-520(B) 51 =-520(B) 53=-487(B) 54=-4,87(B) 55=-487(B) 56=-487(B) Trapezoidal Loads (pit) Vert: 1=-92-to-43=-20 24) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=6, 5-7=48, 7-12=25,12-13=16,20-29=-12, 4-8=-6,18-26=-18,15-17=-12, 12-15=17 Horz: 1-5=-18,7-12=37,12-13=28, 36-38=29 Concentrated Loads (lb) Vert: 3=-248(B) 27=-30(B) 1=-242 18=-1366(B) 21=-30(B) 39=-248(B) 40=-248(B) 41=-248(B) 42=-248(B) 43=-927 44=-30(B) 45=-30(B) 46=-30(B) 47=-30(B) 48=-30(B) 49=-30(B) 50=-30(B) 51=-30(B) 53=10(B) 54=10(B) 55=10(B) 56=10(B) Trapezoidal Loads (pit) Vert: 1 =-66-to-43=6 25) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber lncrease=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=25,5-7=48, 7-12=6,12-13=26,20-29=-12, 4-8=-6, 18-26=-18,15-17=-12, 12-15=17 Horz: 1-5=-37, 7-12=18, 12-13=38, 36-38=29 Concentrated Loads (lb) Veil: 3=-267(B) 27=-30(6) 1=-250 18=-1366(B) 21=-30(B) 39=-267(B) 40=-267(B) 41=-267(B) 42=-267(B) 43=-946 44=-30(B) 45=-30(6) 46=-30(B) 47=-30(B) 48=-30(6) 49=-30(B) 50=-30(B) 51 =-30(B) 53=1 O(B) 54=1 O(B) 55=1 O(B) 56=1 O(B) Trapezoidal Loads (pit) Vert: 1 =-47-to-43=25 26) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=-19, 5-7=23, 7-12=-O, 12-13=8,20-29=-20, 4-8=-10, 18-26=-30, 15-17=-20, 12-15=9 Horz: 1-5=-1, 7-12=20, 12-13=28, 36-38=29 Concentrated Loads (lb) j Vert: 3=-222(B) 27=-22(B) 1 =-231 18=-1 358(B) 21 =-22(B) 39=-222(B) 40=-222(B) 41 =-222(B) 42=-222(6) 43=-902 44=-22(B) 45=-22(B) 46=-22(B) 47=-22(B) 48=-22(B) 49=-22(B) 50=-22(B) 51 =-22(B) 53=1 8(B) 54=1 8(B) 55=1 8(B) 56=1 8(B) Trapezoidal Loads (pit) Vert: 11=-91-to-43=19 27) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=-O, 5-7=23, 7-12=-19, 12-13=-11, 20-29=-20, 4-8=-10, 18-26=-30,15-17=-20, 12-15=9 Horz: 1-5=-20, 7-12=1, 12-13=9, 36-38=29 Concentrated Loads (lb) Vert: 3=-241(B) 27=-22(B) 1=-239 18=-1358(B) 21=-22(B) 39=-241(B) 40=-241(B) 41=-241(B) 42=-241(B) 43=-921 44=-22(B) 45=-22(B) 46=-22(B) 47=-22(B) 48=-22(B) 49=-22(B) 50=-22(B) 51 =-22(B) 53=1 8(B) 54=1 8(B) 55=1 8(B) 56=1 8(B) Trapezoidal Loads (pit) Vert: 1 =-72-to-43=-O 28) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=48, 5-7=22, 7-12=22, 12-13=1 4, 20-29=-1 2, 4-8=-6, 18-26=-1 8, 12-17=-1 2 Horz: 1-5=-60,7-12=34,12-13=26 Concentrated Loads (lb) Vert: 3=-290(B) 27=-30(B) 1 =-259 18=-1 366(B) 21 =-30(B) 39=-290(B) 40=-290(B) 41 =-290(B) 42=-290(B) 43=-970 44=-30(B) 45=-30(B) 46=-30(B) 47=-30(B) 48=-30(B) 49=-30(B) 50=-30(B) 51=-30(B) 53=10(B) 54=10(B) 55=10(B) 56=10(B) Trapezoidal Loads (pit) Veil: 1=-24-to-43=48 29) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=11.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=22, 5-7=22,7-12=48,12-13=40, 20-29=-12, 4-8=-6,18-26=-18'12-17=-12 Horz: 1-5=-34, 7-12--60, 12-13=52 Concentrated Loads (1b) Vert: 3=-264(B) 27=-30(B) 1 =-249 18=-1 366(B) 21 =-30(6) 39=-264(B) 40=-264(B) 41 =-264(B) 42=-264(B) 43=-943 44=-30(B) 45=-30(B) 46=-30(B) 47=-30(B) 48=-30(6) 49=-30(B) 50=-30(B) 51 =-30(B) 53=1 O(B) 54=1 O(B) 55=1 O(B) 56=1 O(B) Trapezoidal Loads (pit) I Vert: 1=-50-to-43=22 30) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd Parallel: Lumber Increase=1.60, Plate lncrease=1.60 Uniform Loads (pill Vert: 5-43=48, 5-7=22, 7-12=22, 12-13=1 4, 20-29=- 12, 4-8=-6, 18-26=-1 8, 12-17=-1 2 Horzi 1-5=-60, 7-12=34,12-13=26 Concentrated Loads (lb) Vert: 3=-290(B) 27=-30(B) 1 =-259 18=- 1 366(B) 21 =-30(B) 39=-290(B) 40=-290(B) 41 =-290(B) 42=-290(B) 43=-970 44=-30(B) 45=-30(B) 46=-30(B) 47=-30(B) 48=-30(B) 49=-30(B) 50=-30(B) 51 =-30(B) 53=1 O(B) 54=1 O(B) 55= 1 O(B) 56=10(B) Trapezoidal Loads (pit) Vert: 1 =-24-to-43=48 31) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 4th Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=22, 5-7=22, 7-12=48, 12-13=40, 20-29=-12, 4-8=-6,18-26=-18, 12-17=-12 Horz: 1-5=-34, 7-12=60,12-13=52 I WARNING -Verity design parameters and REAV NOTES ON THIS AND INCLUDEDWTEI(REFERANCE PAGE 11111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with M!Tek(D conneciors. ]his design Is based only upon parameters shown, and is for an Individual building component, not a Ituss system. Before use, the Wilding designer i nusi verify the apoicability of design parameters and properly Incorporate this design Into Ihe overall individual Iruss members only. Addilioryal lemporary and permanent bracing MiTek' building design. Bracing Indicaled is to prevenl buckling or web and/or chord is always required for stability and to prevent collapse with possible personal injnry and property damage. For general guidance regarding the 6904 Parke r=ast Blvd. fabricatiorL storage. delivery, erection and bracing of trusses and truss systems. seeANSWIl Quaffly Cjftdo, DSB-89 and 6CSf Suffdhlg Component Tampa, FL 33610SafetyInformatiotiavallaNefromTRISSPlateInslikite, 218 N. Lee Street. Suite 312, Nexandrio. VA 22,il 4. Job Truss Truss Type Oty Ply T14165136 744031 A04G ATTIC 1 4 Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 8.130 s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:21:41 2018 Page 6 ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-NxeW-LOD8FQgqkAOxANXGL3OPzlsNOHSEnjG1 NzBOeu LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=-264(B) 27=-30(B) 1 =-249 18=-1 366(B) 21 =-30(B) 39=-264(B) 40=-264(B) 41 =-264(B) 42=-264(6) 43=-943 44=-30(B) 45=-30(B) 46=-30(B) 47=-30(B) 48=-30(B) 49=-30(B) 50=-30(B) 51=-30(B) 53=10(B) 54=10(B) 55=10(B) 56=10(B) Trapezoidal Loads (plf) Vert: 1=-50-to-43=22 32) Reversal: Dead + 0.6 MWFRS Wind (Neg. internal) 1 st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=23, 5-7=-3, 7-12=-3, 12-13=6, 20-29=-20, 4-8=-10, 18-26=-30, 12-17=-20 Horz: 1-5=-43, 7-12=17,12-13=26 Concentrated Loads (lb) Vert: 3=-265(B) 27=-22(B) 1=-248 18=-1358(B) 21=-22(B) 39=-265(B) 40=-265(B) 41=-265(B) 42=-265(B) 43=-944 44=-22(B) 45=-22(B) 46=-22(B)47=-22(B) 48=-22(B) 49=-22(B) 50=-22(B) 51 =-22(B) 53=1 8(B) 54=1 8(B) 55=1 8(B) 56=1 8(B) Trapezoidal Loads (plf) Vert: 1 =-49-to-43=23 33) Reversal: Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=-3, 5-7=-3, 7-12=23, 12-13=32, 20-29=-20, 4-8=-10, 18-26=-30, 12-17=-20 Horz: 1-5=-1 7, 7-12=43,12-13=52 Concentrated Loads (lb) Vert: 3=-239(B) 27=-22(B) 1 =-238 18=-1 358(B) 21 =-22(B) 39=-239(B) 40-239(13) 41 =-239(B) 42=-239(B) 43=-918 44=-22(B) 45=-22(B) 46=-22(6) 47=-22(B) 48=-22(B) 49=-22(B) 50=-22(B) 51 =-22(B) 53=1 8(B) 54=1 8(B) 55=1 8(B) 56=1 B(B) Trapezoidal Loads (pit) Vert: 1=-75-to-43=-3 34) Reversal: Dead,+ 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber lncrease 1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=-50, 5-7=-18, 7-12=-35, 12-13=-29, 20-29=-20, 4-8=-1 0, 18-26=-90, 15-17=-20, 12-15=2 Horz: 1-5=-O, 7-12=1 5, 12-13=21, 36-38=22 Concentrated Loads (lb) Vert: 3=-364(B) 27=-308(B) 1=-392 18=-2051 (B) 21 =-308(B) 39=-364(B) 40=-364(B) 41 =-364(B) 42=-364(B) 43=-1 381 44=-308(B) 45=-308(B) 46=-308(B) 47=-308(B) 48=-308(B) 49=-308(B) 50=-308(B) 51 =-308(B) 53=-273(B) 54=-273(B) 55=-273(B) 56=-273(B) Trapezoidal Loads (pit) Vert: 1=-122-to-43=-50 35) Reversal: Dead + 0.75 Roof Live (bal.) + 0:75 Uninhab. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=-35, 5-7=-18, 7-12=-50, 12-13=-43, 20-29=-20, 4-8=-10, 18-26=-90, 15-17=-20, 12-15=2 Horz: 1-5=- 15, 7-12=0, 12-13=7, 36-38=22 Concentrated Loads (lb) Vert: 3=-378(B) 27=-308(B) 1 =-397 18=-2051 (B) 21 =-308(B) 39=-378(B) 40=-378(B) 41 =-378(B) 42=-378(B) 43=-1 395 44=-308(B) 45=-308(B) 46=-308(B) 47=-308(B) 48=-308(B) 49=-308(B) 50=-308(B) 51 =-308(8) 53=-273(B) 54=-273(B) 55=-273(B) 56=-273(6) Trapezoidal Loads (plf) Vert: 1=-107-to-43=-35 36) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75 Uninhalb. Attic Storage + 0.75Attic Floor+ 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase= 1 .60, Plate Increase=1.60 Uniform Loads (pit) Vert: 5-43=-18,5-7=-37, 7-12=-37,12-13=-31, 20-29=-20,4-8=-10' 18-26=-90, 12-17=-20 Horz: 1 -5=-32, 7-12=1 3,12-13=1 9 Concentrated Loads (Ilb) Vert: 3=-396(B) 27=-308(B) 1 =-404 18=-2051 (B) 21 =-308(B) 39=-396(B) 40=-396(B) 41 =-396(B) 42=-396(B) 43=-1 413 44=-308(8) 45=-308(B) 46=-308(B) 47=-308(B) 48=-308(B) 49=-308(B) 50=-308(B) 51--308(B) 53=-273(B) 54=-273(B) 55=-273(B) 56=-273(B) Trapezoidal Loads (plf) Vert: 1=-90-to-43=-18 37) Reversal: Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 5-43=-37, 5-7=-37, 7-12=-18, 12-13=-1 1, 20-29=-20, 4-8=-10, 18-26=-90, 12-17=-20 Horz: 1-,5=-13, 7-12=32, 12-13=39 Concentrated Loads (lb) Vert: 3=-376(B) 27=-308(6) 1 =-396 18=-2051 (B) 21 =-308(B) 39=-376(B) 40=-376(B) 41 =-376(B) 42=-376(B) 43=-1 393 44=-308(B) 45=-308(B) 46=-308(B) 47=-308(B) 48=-308(B) 49=-308(B) 50=-308(6) 51 =-308(B) 53=-273(B) 54=-273(B) 55=-273(B) 56=-273(B) Trapezoidal Loads (pit) Vert: 1=-109-to-43=-37 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11411-7473 rev. 10,W/2015 BEFORE USE. Design valid for use only Wth MiTekO connectors. This design Is based only upon parameters shown. and Is for an Individual building component, not a Iruss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the Overall building design. Bracing Indicated is to buckling of individual Iruss web and/or chord members only. Addilion(itternp,)rary(indperryianenibrc),-Ing MiTek' prevent is always required for stability and to prevent collapse with possible personal Injury and property damagc. For geneial guidance regarding the fabricallorf, storage. delivery. erection and bracing of trusses and truss systems. w.eAAISMI1 Qualffly Ciftria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Informiationavallable from Trim Plate Institute, 218 N. Lee Street, Suite 312, Nexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type Q ty ply T14165137 744031 A05 ATTIC 3 1 Job..Reference (optional) American buirclers 6upply, vvimer Haven, t-L 33trtrJ 0''u b`a7' ' ' "'. "" - "'.—u—, -- .—Y — -- ., V. ID:pBo2QDQ4UzF_Agn3M51CIGzTvbv-JKmGPlQTgsgN32KP2bP?Lm8Nbng rlsli5CN FzBOes 7-4-2 14-8-4 - M,11 %1-1%4 1 2:-,l 1_1 - 1 36-6-0 2 -01 -_I 48-6-0 49-1 -4 7-4-2 7__ 116 %4 7-6-4 _0 6-0-0 -4044_2 2_ 21 , 5x6 = 6.00F1_2 2x4 11 5X6 6 7 Scale = 1:91.6 c 7 4x6 39 6 7 14-0-0 42 E679 19 EEI 1 f IZ' 28 27 26 257x8 21 20 4x12 4x12 = 16 15 14 1.5x8 STP 5xl 4 23 7x10 I 3xl 0 11 4x12 17 2x4 I I 1,5xS STP — 2X4 11 4x6 4x8 I M MT20HS 2x4 I I 4x12 7x8 = 7xB = 7 4 4-,84 73 01-6-0 2EI- -12 36-6-0 42-6-0 8-2-4 8--O 7 4-2 2 2_7-4 2-10-Ei 840 2 7-6-4 6-0-0 5_8_4 01 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-81, [5:0-3-0,0-2-0],17:0-3-0,0-2-0], [12:0-0-4. Edge], 112 70-0-4, Edge], 15:0-3-8,Edgel, [19:0-7-0,0-1-81, [22:0-7-0,0-3-8], 24:0-3-12,0-3-8]_ LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in (loc) I/clefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) 0.62 20 703 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.88 Vett(CT) 1.09 20 399 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.98 Horz(CT) 0.15 12 n/a n/a BCDL 10.0 Code FBC2017f-FP12014 Matrix -AS Wind(LL) 0.44 21 997 240 Weight: 372 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORD 2x4 SP No.2 *Except* BOTCHORD Rigid ceiling directly applied. 18-24: 2x4 SP M 31, 18-24: 2x6 SP 240OF 2.OE JOINTS 1 Brace at Jt(s): 31, 32, 33, 22 WEBS 2x4 SP No.3 *Except* 4-33: 2x6 SP 240OF 2.OE, 24-27: 2x4 SP No.2. 8-33: 2x6 SP No.2 WEDGE Right: 2X4 SP No.3 REACTIONS. (lb/size) 28=1 893/0-8-0, 15=1 130/0-8-0, 12=1 359/0-3-0 Max Horz 28=-403(LC 13) Max Uplift 28=-446(LC 12), 15=-779(LC 13), 12=-302(LC 12) Max Grav 28=2149(LC 2), 1 5=1414(LC 25), 12=1591(LC 2) FORCES. (11b) - Max. Comp./Max. Ten. - All forces 250 (11b) or less except when shown. TOPCHORD 1-2=-2599/1093,2-4=-3213/1343, 4-5=-1884/833, 5-6=-1711/817, 6-7=-1711/817, 7-8=- 1895/867, 8-1 0=-3175/1371, 10-11 =-2639/1321, 11-12=-2785/1743, 1-28=-2078/926 BOTCHORD, 27-28=-170/379, 25-27=-728/981, 23-25=-835/1181, 21-23=-835/1181, 22-24=-181/2986, 19-22=-764/2836, 18-19=-764/2836 14-15=-1362/2454, 12-14=-1362/2454 WEBS 2-27=-984/412, 2-24=-48/718, 24-25=-84/853, 24-29=-206/969, 18-30=-162/836, 4-29=-1259/576, 29-31=-1279/577, 31-33=-1244/567, 32-33=-1244/567, 30-32=-1288/582, 8-30=_1 2651576, 1-27=-895/2318, 10-15=-1 182/601, 10-18=-219/877, 15-18=-849/2327, 11-15=-454/586,11-14=-263/167,24-27=-171/2273,5-31=-154/577,7-32=-207/727, 6-33=-289/230, 19-21=-438/613, 22-25=-1532/210, 21-22=-1306/924 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCp!=0.18 MWFRS (envelope) gable end zone and C-C Extprior(2) 0-1-12 to 4-11-,15, Interior(l) 4-11-15 to 16-10-4, Exterior(2) 16-10-4 to 31-8-7, Interion(l) 31-8-7 to 49-10-4 zone; cantilever right exposed ; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water poncling. 4) All plates are MT20 plates unless otherwise indicated. 5) All plates are 3x6 MT20 unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Ceiling dead load (5.0 psf) on member(s). 4-29, 29-31, 31-33, 32-33, 30-32, 8-30 9) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 22-24, 19-22, 18-19 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 446 lb uplift at joint 28, 779 Ito uplift at joint 15 and 302 lb uplift at joint 12. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert $634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING -Verify design parameters and REAGNOrES ON THIS AND iNCLUDEDMITEKREFERANCE PAGE M11-7473 rev. IOIV312015,BEFORE USE. oil" Design valid for use only Willi MiTekO connectors. ]his design Is based only upon parameters shown, and Is for an lndl clual building component not a truss system. Before use, the building designer must Veft the alAAlcobility of design parameters and property Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permarient bicicing Welk' Is always required foi stability and to prevent collapse with possible personal Injury and Property damage. for general gUidame regarding the fabricatiorL storage. delivery. erection and bracing of trusses and tiuss systems. seeANSWI1 Quaffly Crifeda, DSO-49 and OM Buirdbig Component 6904 Parke East Blvd. Safety h9armatillaitavallalble from TrUSS Plate Institute, 218 N. Lee Street. S ulte, 312, Alexandria, VA 22,314. Tarnpa, FL 33610 Job Truss Truss Type Qty Ply T14165137 744031 A05 ATTIC 3 1 lob Rpfprpnrp (optional) American buijcfers,,uppiy, vvimer Haven, r-L 6,50M ID:pBo2QDQ4UzF—Agn3M51CIGzTvbv-5 w 6'N"32KP2bP?Lm8NbngMrIsli5CN5FzBOes NOTIES- 11) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 12) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABlTABLE. A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. lers shown, and is for an individual building component. no, Design valid for use only with MiTekO connectors. This design is based only upon parome ',,all RONatrusssystem. Before use. Me building designer Tnusi verify the applicability of design parameters and properly incorporate this design into the o\ building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord fnernbers only. Addilionai temporaryand permanent bracing MiTek' Is always required for stabilily I and to prevent collapse vAth possible f-warsoncil Injury and property damage. For general guidance regarding 'he Infabrication. storage. delivery. erection and bracing of trusses and truss systems, seeANSL11pil Quality Ciftirla, DSB-89 and BCSI Building Compont t 6904 Parke East Blvd. Safety Intannaftrinvallat-AE, from RUSS Plato Institute, 218 N. Lee Street. Sulte 312, Alexandria, VA 22314 Tampa, FL 33610 Job Truss Truss Typ oty Ply T14165138 744031 A06 ATTIC Job Reference (optional) iAmerican buimeis zuppiy, VV Intel md-, -o - - - . -1 . .. - , .. -.- -. .. - .. I __ __'_ - '_ __ - ID:pBo2QDQ4UzF Agn3M51CIGzTvbv-FjtlqiRICTw5lMToAORTQBDIKaNzJE529PhTABzBOeq 7-4-2 14 8_4 16-10-41 21-104 26 10-4 0 42-6-0 4111-60 4P-1 03 -6-, 7-4-2 7-4-2 2-2- 510-0 ? 11 -11- -.1 9 7664 Scale = 1:88.8 6.00 [1-2 5x6 - 2x4 11 5 44 6 45 4x6 5x6 7 31 30 29 Z' 26 24 22 20 " 16 is 14 1.5x8 STP 4x-12 gAs 2.4 11 2x4 11 4x6 1.5x8 STP 2x4 11 4x6 4X8 4X6 11 7xg 4 48174--2 17 6 1 20-10-4 22-10-4, 25-11-14 28-6-0 0 42-6-0 48-2-4 1 4E 5-0 2 1 _: 3-1-14 ' 2-0-0 ' 3-1-10 2-6-2 0-6-12 16 -4 6-0-0 5-8-4 0--`l 2 Plate Offsets( (,Y)-- 1:0-3-0,0-1-81, [570-3-0,0-2-0],17:0-3-0,0-2-71, f1 2:0-0-4, Edge], [112:0-0-4 Edge], [15:0-3-8, Ec1gpJJ1 8:0-6-8,0-4-01, [28:0-5-8,0-3-41 LOADING (psf) TCLL 20. SPACING- Plate Grip DOL 2-0-0 1.25 CS1. TC 0.69 DEFL. in (loc) Vert(LL) -0.25 23-25 I/clefl 999 Ud 360 PLATES MT20 GRIP 244/190 TCDL 10. Lumber DOL 1.25 BC 0.80 Vert(CT) -0.49 23-25 894 240 BCILL 0-0 BCDL 10.0 Rep Stress Incr Code FBC2017fTP12014 YES WB 0-87 Matrix -AS Horz(CT) 0.08 12 Wind(LL) 0.19 29-30 n/a 999 n/a 240, Weight: 352 lb FT = 20% LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP N0.2 *Except* 118-28: 2x4 SP M 31, 17-27: 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 4-36,8-36: 2x4 S P M 30 WEDGE Right 2x4 SP No.3 REACTIONS. (lb/size) 31=1800/0-8-0, 15=1882/0-8-0, 12=878/0-3-0 Max Horz 31 =-403(LC 13) Max Uplift 31 =-413(LC 12), 15=-376(LC 13), 12=-388(LC 9) Max Grav 31 =1 940(LC 2), 15=2304(LC 27), 12=878(LC 1) BRACING- TOPCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 2-28,10-15 JOINTS 1 Brace at Jt(s): 34, 35, 36, 23, 21, 25, 19 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-2328/575, 2-4=-2467/629, 4-5=-1 566/520, 5-6=-1 407/532, 6-7=-1407/532, 7-8=-1569/547, 8-10=-2442/680, 10-11=-841/610,11-12=-1234/1053, 1-31=-1875/520 BOTCHORD 30-31--169/378, 29-30=-564/2474, 26-29=-91/3107, 24-26=0/2781, 22-24=0/2781, 20-22=0/2781, 16-20=0/1272, 15-16=-964/109, 14-15=-750/1050,12-14=-750/1050, 25-28=-464/427,23-25=-1211/0,21-23=-1056/170, 19-21=-444/1150, 18-19=-270/3093 WEBS 2-30=-488/234, 2-28=-1 07/323, 28-29=0/580, 28-32=0/554, 16-18=0/1 283, 18-33=-52/518, 4-32=-860/276, 32-134=-856/274, 34-36=-831/280, 35-36=-831/280, 33-35=-860/281, 8-33=-852/279,1-30=-410/2057,10-15=-2153/327,10-18=0/1941, 15-18=-448/1547, 11-15=-489/603,11-14=-274/213,28-30=-472/142, 5-34=0/435, 7-35=-25/504, 21-22=-10/291, 25-29=-1068/0,23-26=-395/595,16-19=-2505/0, 19-20=0/667, 20-21 =-I 736/31 NOTES- , 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 4-11-15, Interjor(l) 4-11-15 to 16-10-4, Exterior(2) 16-10-4 to 33-8-9, Interior(l) 33-8-9 to 49-10-4 zone; cantilever right exposed ; porch right exposed;C-C for members and forces & MWFRS for reactions shown-, Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 3x6 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom cho.rd in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Ceiling dead load (5.0 psf) on member(s). 4-32, 32-34, 34-36, 35-36, 33-35, 8-33 8) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 25-28, 23-25, 21-23, 19-21, 18-19 Joaquin Velez PIE No.68182 MiTek USA, Inc. FIL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING - V.,Jfy desig p.,...te d READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 1010312015 IIEFORE USE. Design valid for use only with M!Tek@ connectors. 11his design is based only upon parameters shown, and is for an individual L -Aillding component, nor a truss system. Before use. the building designer must verify the app4icablilty of design parameters and property inc6riporate this design Into the oveii :111 building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage. defiveiy, ereclion and bracing of fusses and truss systems. seeANSWI1 Quaffly Cffleillm DSB-89 and BCSI! BuIldbig Component 6904 Parke East Blvd. Safety Antannaffonavallainte from TFUSS PICtie Instrute. 218 N. Lee Street, Suite 312. Nexandria, VA 22314. Tampa, FIL 33610 Job Truss Truss Type oty Ply T14165138 744031 A06 ATTIC 1 1 Job Reference (optional) American tifiiiaers zuppry, VVIFflel "dVell, rL -00V — -1.1 .- - -1 __ __ - - - '_ __ ' - - ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-jvRP22SMzn3ywW2 jkyizPmw4-iC2hLB03QliazBOep NOTES- 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 413 b uplift at joint 31, 376 lb uplift at joint 15 and 388 lb uplift at joint 12. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 11) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. WARNING -Verity design parameters and READ NOrES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 10M,2015 BEFORE USE. Design valid for use only with MiTokO connectors. ]his design is based only upon parameters shown. and is for an individual building component, not a truss sysiern. Before use, 1he. building designer must verily the applicability of design pararnelers and properly incorporate this design into the overall buildingdesign. Bracing indicated is to rxevent txickling ofindividual truss web and/or chord rnernbers only. Additional lernporary and permanent bracing MiTek' is always requilred-fur stability and to prevent collapsevAth possiNe personal injury and property damage. For general guidance regarding the fabricatfor, storage. delivery, erection and bracing of trusses and truss systems. s0eANSMI1 Qualfly Ciftda, DSB.89 and 0CS1 BuIldiing Component 6904 Parke East Blvd. SafetIy Intofmciftinavailolole from Iruss Plate Institute, 218 N. Lee Street, Suite 312. Nexandria, VA 22314, Tampa, FL 336 1 1 6 Job Truss russ yp Qty Ply T14165139 744031 A07 GABLE 1 1 Job Reference (optional) American urricliers 5upply, winter maven, f-L 0,50OU 7- - - -- - - I ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-vOcZLpaFN9ROIC05tYfHvjjp2.Qax7eXpwHb6bRzBOee 1484 16-10- 21 10-4 26 10-4 28-1 1-1 36-6-0 42-6-0 48-6-0 4 - 04 74-2 2-2-Oi 510- 5 0-0 12-1-81 7-6-4 6-0-0 6-0-0 -4- T SX6 6.00 F1 2 5x6 1 5 120 6 121 7 5x6 lj 6 3635 34 33 32 31 30 27 25 23 21 17 16 Is 14 M 11 4x8 28 3x6 = M = M 8 1.5x8 STP 4x6 3,xA' g:_- 3x6 M = 5X6 5x8 3x6 3X6 M Scale = 1:102.0 28-11-12 7-4-2 17-8 r _ 0 10 4 2-fo4 11.14 1 2 - -0 36-6-0 42-6-0 _8-82 4 4 0 7__4_2 -b-4 6-0-0 4 0 1 2 7_4_2 2 . o 262 1 0-5-12 Plate Offsets (,Y)-- [1:0-2-12,0-2-01,[4:0-2-0,0-2-8], [5:0-3-12,0-2-12], [7:0-3-12,0-2-12], [104:0-1-15,0-1-0), 1107:0-1-15,0-1-0], [15:0-3-8,0-3-0], [19:0-5-8,0-3-41, 129:0-5-8 0-3-4L f5l:0-1-9,0-1-01, f68:0-1-1 1,0-1-01, f70:0-1-111,0-1-01,[72.0-1-1 1,0-_1-0 , 182:0-1-9,0-1-0], [98 0-1-15,0-1-01L7 LOADING (psf) SPACING- 2-0-0 CS11. DEFL. in (loc) TCLL 20.0 Plate Grip DOL 1.25 TC 0.65 Vert(LL) 0.06 14-15 TCDL 10.0 Lumber DOL 1.25 BC 0.34 Vert(CT) -0.05 31-32 o Re Str- Incir YES WB 091 Horz(CT) 0.03 12 BCDL 10.0 Code FBC2017/TPI2014 Matrix -AS LUMBER- BRACING- TOPCHORD 2x4 SI P No.2 TOP CHORD BOTCHORD 2x4 SP N0.2 *Except* BOTCHORD 19-29: 2x4 S P M 31 JOINTS WEBS 2x4 SP No.3 *Except* 4-41,8-41: 2x4 SP No.2 OTHERS 2x4 SP No.3 REACTIONS. All bearings 36-10-0 except at=Iength) 12=0-3-0. lb) - Max Horz 36=-403(LC 13) Max Uplift, All uplift 100 lb or less at joint(s) 35 except 36=-296(LC 13), 32=-379(LC 12), 30=-205(LC 25), 17=-281(LC 24), 15=-632(LC 8), 12=-322(Lc 8) Max Gr I av All reactions 250 Ib or less at joint(s) 30, 17, 31, 33, 34, 35, 16 except 36=723(LC 1), 32=887(LC 1), 15=1 573(LC 1), 15=1 573(LC 1), 25=339(LC 18), 23=331 (LC 18), 27=449(LC 18), 21 =439(LC 18),12=725(LC 1) FORCES. (1b) - Max. Comp./Max. Ten. - All forces 250 (1b) or less except when shown. TOPCHORD 1-2=-726/436, 2-4=-1 291/848, 4-5=-1 0751635, 5-6=-934/613, 6-7=-934/613, 7-'8=l 074/627, 8-1 0=-1288/839, 10-11 =-430/234,11-12=-896/661, 1-36=-662/431 BOTCHORD 35-36=-1 92/360, 34-35=-1 92/360, 33-34=-1 92/360, 32-33=-1 92/360, 31-32=-1 51/403, 30-31=-151/403, 27-30=-129/385, 25-27=-84/278, 23-25=-84/278, 21-23=-84/278, 17-21=-104/349,16-17=-78/292,15-16=-78/292,14-15=-463/728, 12-14=-463/728, 26-29=-202/670, 24-26=-220/687, 22-24=-265/793, 20-22=-2451722, 19-210=-284/780 WEBS 2-32=-996/58412-29=-230/552,29-37=-279/159,17-19=-246/315,19-38=-297/173, 4-37--186/322, 37-39=- . 185/322, 1 39-41=-181/321, 40-41=-181/321, 38-40=-185/315, 8-38 ='- 186/316, 1-32=-233/534, 10-15=- 1236/732, 10-19--460/870, 11-15=-460/588, 11 -1 4=-259/224, 24-25=-289/100, 22-23=-281/90, 26-27=-393/131, 20-21 =-377/112 I/defl Ud PLATES, GRIP 999 240 MT20 244/190 999 240 n/a n/a Weight: 529 lb FT = 20% Structural wood sheathing directly applied, except end verficals. Rigid ceiling directly applied. 1 Brace at Jt(s): 39, 40, 41, 24, 22, 26, 20 NOTES- 1) Unbalanced root live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasc1=1 08mph; TCDL=6.Opsf; BCDL=6.opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Extedor(2) 0-1-12 to 4-11-15, Interjor(l) 4-11-15 to 16-10-4, Exterior(2) 16-10-4 to 33-8-9, Interior(l) 33-8-9 to 49-10-4 zone; cantilever right exposed ; porch right exposed;C-C for members and forces & MWFRS for reactio ns, shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss desigried for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Joaquin Velez PE No.68182 Gable End Details as applicable, or consult qualified building designer as per ANSIITPI 1. MiTek USA, Inc. FL Cert 6634 4) Provide adequate drainage to prevent water ponding. 6904 Parke East Blvd. Tampa FL 33610 51 ) All plates are 2x4 MT20 unless otherwise indicated. Date: 6) Gable studs spaced at, 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. May 30,2018 WARNING - Verjjy desj n parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M114473 ral 1010312015 BEFORE USE. M, Design valid for use only with MiTek(& connectors. This design is based only upon parameters shown. and is for in individual building component. not Natrusssystem. Before use, ]he building designer must verify the applicability of design parameters and property incorpoiate, this design Into the overall acing MiTek' building design. Biacing indicated is to prevent buckling of individual truss web and/or chord mernbefs only. Additional lemly,>rary and pennanenil br is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fahAlcallon, storage. delivery. erection and bracing of trusses and truss systems. seeANS111pil Quaffly CIftria, DSB.89 and BCSI BuRdtfigi COMPOnimt 6904 Parke East Blvd. Saletykdotmuffoncivailable from Truss Plate institute, 218 N. Lee,, Street Suite. 312, Alexandria, VA 223 14. Tampa, FL 33610 Job Truss Truss Type Oty , Ply T14165139 744031 A07 GABLE 1 1 Job Reference optional) American Builders Supply, Winter Haven, FL 33880 8.130 s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:21:57 2018 rage 2 ID:pBo2QDQ4UzF Agn3M51CIGzTvbv-vOcZLpaFNgROIC05tYfHvjjp2Qax7eXpwHb6bRzBOee NOTES- 8) *,This, truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Ceiling dead load (5.0 pst) on member(s). 4-37, 37-39, 39-41, 40-41, 38-40, 8-38 10) Bottom chord live load (40.0 pst) and additional bottom chord dead load (5.0 psf) applied only to room. 26-29, 24-26, 22-24, 20-22, 19-20 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 35 except at=lb) 36=296, 32=379, 30=205, 1 7=281 , 15=632,12=322. 12) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 112" gypsum sheetrock be applied directlyto the bottom chord. 13) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERAOVCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only \vith MiTek(Doonnectois. ]his design is based only upon parameters shown. and is for on individual building component, not a truss system. Before use. the building designer must verify the app4loobility of design parameters and ptop-rly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual Truss web (Ind/of Chord mernbers only Additional ternporary and permanent bradng MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication. storage. delivery. erection and bracing of trusses and truss systems. seeANSMIJ Quality Crftda. DS11-89 and BCS1 Bundlng COMPOnAtnt 6904 Parke East Blvd. Satetyintofmatlowivailable from Truss Plate Insfilute. 218 N. Lee Street, SUlteM2, Alexondria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply T14165140 744031 B01 GABLE Job Reference (optional) American buiiaers ouppy, VV Intel Maven, r- L 0,300V .. I - . I -I I . .- I- I - - .-Y - --- I - - . ' . ID:Pyl2dFQWAAaLOH2p9JrnQ3YzTvad-nor4BBdmROxqDpis6NjD4ZuUAlwg3dGOrvZKkDzBOea 17-10-8 26-7-5 44 7 2 175-0-4 17-8-1 '1 20_2_0 24-2-0 6-5-8 29-3-12 1-14 44-4-0 5 g_ 0 6-2 -0-1) -138 Z8-7 2 7 7-6-2 41-4802-8-710-V13 4 2-3-8 0-1-13 Scale = 1:88.1 8X8 M = 6 M 11 3x6 11 5 M I 1 8 3x6 11 4 37 3x6 11 IWO s' 3x6 11 6. 00 1-2 3 9 77 2 M 36 36 34 33 32 31 28 4x4 29 M 168-- SX8 - 7 3x6 8 3x6 11 3x6 11 38 799 3x6 11 X6 11 3x6 11 3x6 I 3x6 11 3x6 11 79 9 '3x6 'I 3x6 36 11 31 1OX10 10 21- 80 d) 12 1- 6 26 24 22 18 17 16 15 14 13 1 5X8 STP 3x4 = 3x4 = 19 4x4 3X6 M 22-2-0 111 0-4 21-2-0 2-2-9 1 2I313-'122 1 29_1-12 36-9-14 44-4-0 6-2 -6-217 .2 3-1-12 1-0-0 i_, ._6 7 7 1-0-0 Plate Offsets (X,Y)-- [6:0-4-0,0-3-81, [7:0-4-0,0-3-8], [20:0-2-8,0-2-8], [30:0-2-8,0-2-81, [41:0-1-10,0-1-01, [45:0-1-10,0-1-0), [48:0-1-10,0-1-0], [51:0-1-10,0-1-0], [60:0-1-10 0-1-01, [66:0-1-10,0-1-01, [69:0-1-10,0-1-0], [72:0-1-10,0-1-0] LOADING (pst) SPACING- 2-0-0 CS1. DEFL. in (loc) I/cletl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vett(I-L) 0.06 31-32 999 360 TCDL 10.0 Lumberr DOL 1.25 BC 0.39 Vert(CT) 0.11 31-32 793 240 BCLL 0.0 Rep St ess Incr YES WB 0.22 Horz(CT) 0.01 11 n/a n/a BCDL 10.0 Code FBC2017/-FP12014 Matrx-S Wind(LL) 0.01 2-36 999 240 LUMBER - TOP CHORD 2x4 SP N0.2 *Except* 3-6,7-10: 2x8 SP No.2, 6-7: 2x6 SP No.2 BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. All bearings 44-4-0 PLATES GRIP MT20 244/190 Weight: 413 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 25, 23, 27, 21, 37, 38 lb) - Max Horz 2=-279(LC 17) Max Uplift All uplift 100 lb or less atjoint(s) 28, 35, 14 except 2=-106(LC 13), 18=-270(LC 13), 17=-246(LC 13), 31=-286(LC 12),32=-291 (LC 12), 1 1=-121(LC 13), 33=-158(LC 3), 36=-130(LC 12), 16=-158(LC 3),13=-130(LC 13) Max Grav All reactions 250 lb or less at joint(s) 34, 35, 36, 15, 14, 13 except 2=323(LC 1), 18=597(LC 25), 17=858(LC 1), 31=627(LC 24), 32=858(LC 1), 11 =321 (LC 1), 11 =321 (LC 1), 26=340(LC 18), 24=334(LC 18), 28=382(LC 18), 22=393(LC 18) FORCES. (b) - Max. Comp./Max. Ten. - All forces 250 (Ilb) or less except when shown. TOPCHORD 2-3=-333/191, 3-4=-664/428, 4-5=-668/607, 5-6=-634/445, 7-8=-634/445, 8-9=-668/608, 9-1 0=-664/429, 10-11 =-321/197, 6-7=-579/433 BOTCHORD 2-36=-57/294, 35-36=-57/294, 34-35=-57/294, 33-34=-57/294, 32-33=-57/294, 26-28=-1 2/294, 24-26=-12/294, 22-24=-5/255, 23-25=-10/287, 21-23=-10/287, 20-21 =-1 7/325 WEBS 18-20=-471/491, 9-20=-484/537, 10-17=-704/548, 30-31=-501/479, 4-30=-484/536, 3-32=-701/551, 25-26=-282/0, 23-24=-277/0, 27-28=-372/0, 21-22=-373/0, 3-30=0/295, 10-20=-25/358 NOTES- 1) unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult-140mph (3-second gust) Vasd=1 08mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Corner(3) -1-4-13 to 3-0-7, Exterfor(2) 3-0-7 to 20-2-0, Corner(3) 20-2-0 to 24-2-0, Exterior(2) 28-7-3 to 45-8-13 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSIfTPI 1. 4) Provide adequate drainage to prevent water poncling. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Joaquin Velez PE No.68182 MiTek USA, Inc. FIL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: May 30,2018 bottom chord and any other members. WA RNING - Verify design parameters and REA D NOTES ON THIS AND INCL UDED M1TEK REFERANCE PA GE M11- 7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectofs, this design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer i nusi verify the cpr dcablllty of design parameters and properly incorporate this design into the overall buildingdesign. Bracing lnd ccated is to prevent buckling of individual truss web and/or, ctmd members only. Additional temporary and permanent bf. Ing MiTek' Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication. storage, delivery, erection and bracing of trusses and truss systems. se.eAAWMIJ Quaffly Chtedd, DSB-89 and BCSf Buildblig Component 6904 Parke East Blvd. Safety kdonnatim-wallat-Ae from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply T14165140 744031 B01 GABLE 1 1 Job Reference (optional) American 13uilders tiupply, Winter Haven, F-L 33880 8.13o s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:22:01 2018 Page 2 ID:Pyl2dFOWAAaLOH2p9JmQ3YzTvad-nor4BBdmROxqDpis6NjD4ZuUAlw93dGOrvZKkDzBOea NOTIES- 9) Ceiling dead load (5.0 psf) on member(s). 4-5, 8-9, 5-37, 37-38, 8-38 10) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 27-30, 25-27, 23-25, 21-23, 20-21 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 28, 35, 14 except at=lb) 2=106, 1 8=270, 17=246, 31=286,32=291,11=121,33=158,36=130,16=158,13--130. 12) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 1010312019 BEFORE USE. Design valid for use only with Milek0conneclofs, This design Is based onlyupon paiameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Addiflowl temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property clai nage. For general guidance regarding the fabricallon, storage, delivery, erection and bracing of trusses and truss systems. seeANWTPI1 Quaffly Ciftrild, DSB-89 and BCS1 BullidIng Component 6904 Parke East Blvd. Safety thfarmationavallaNe (I Orn Truss Plate. Insil kite, 218 N. Lee Street, Suite 312, Alexandria, VA 22314 Tampa, FL 33610 Job Truss Truss Type oty Ply T14165141 744031 B02 ATTIC 7 1 Job Reference optional) American bUllUerS OUpply, vviniLi riaven, r-L 5000V 0. — I IV— I I I— IVII .—Y — --c— —. —V. I ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-kAzqcsfOy?CYT7sFDomh9 zqQrTbXLUhID2Qp5zBOeY 24- 7-6-2 15-0-4 20-2-0 1 4 - 2 -,0 9 -13 -1 Q W-2-14 44-4-0 -8 5 2 76 7,2 V4W47-6-2 7-6-2 5-1-12 Scale = 1:91.7 8X8 = 8X8 = 4X8 — 4x8 = 6 7 8 39 3x12 11 &12 1! 4 38 29 30 2x4 11 2x4 I F 10X10 6.00F-12 1OX10 -1 T 6 10 u? 3 1.5x8 STP 1.5x8 STP 37 1 14-0-0 40 17_ T2! 1 Is 28 27 24 22 20 18 14 13 3X8 Z- 3X8 5x6 4x6 = 2x4 I j 3x4 = 3x8 = 2x4 I 5x6 2x4 tl 104xli) = 4x6 7-t3-2 15-1-4 1-0413_ 21' -2-0 23-2-0 26-3-12 2j9-3-12 36-,-14 44-4-02_ 1 7, 12 7_6_2 1 J3-1-1 1 7-6:22 _,_0 7_ Plate Offsets (X,Y)-- 12:0-2-9,0-1-8], [5:0-4-0,0-1-12], 16:0-4-0,0-3-8], [7:0-4-0,0-3-8], [8:0-4-0,0-1-12LJI 1.0-2-9,0-1-81, [16:0-2-4,0-2-8 , [18:0-3-8,0-1-8], [26:0-3-0,0-3-0] LOADING (pst) SPACING- 2-0-0 CS11. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.65 Vert(LL) -0.44 19 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.97 Vert(CT) -0.87 19 >612 240 BCLL 0.0 Rep Stress Incr YES WB 1.00 Horz(CT) 0.22 11 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Mattjx-AS Wind(I-L) 0.37 24-27 >999 240 Weight: 330 lb FT 20% LUMBER- BRACING- 2x4 SP N0.2 *Except' TOPCHORD Structural wood sheathing directly applied. 3-6,7-10: 2x8 SP 240OF 2.OE, 6-7: 2x6 SP No.2 BOTCHORD Rigid ceiling directly applied. BOTCHORD 2x4 SP No.2 *Except* WEBS I Row at miclipt 29-30,10-16 15-25: 2x4 SP M 30 JOINTS 1 Brace at Jt(s): 21, 19, 23, 17, 29, 30 WEBS 2x4 SP No.3 *Except* 5-8: 2x4 SP No.2 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 2=2139/0-8-0, 11=2139/0-8-0 Max Horz 2=-280(LC 13) Max Uplift 2=-494(LC 12), 11 =-494(LC 13) Max Grav 2=2323(LC 2), 11 =2323(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - Ali forces 250 (lb) or less except when shown. TOPCHORD 2-3=-4561/812, 3-4=-4017/641, 4-5=-3294/704, 5-6=0/914, 7-8=0/911, 8-9=-3290/701, 9-1 0=-4019/638, 10-11 =-4561/812, 6-7=0/1 189 BOTCHORD 2-28=-789/4022, 27-28=-901/2597, 24-27=-923/2595, 22-24=0/4201, 20-22=0/4201, 18-20=-271/3615,14-18=-760/2578,13-14=-739/2582, 11-13=-584/4022,23-26=-522/447, 21'23=-522/447, 19-21=-1044/0, 17-19=-1044/0,16-17=-492/501 WEBS 14-16=0/258, 9-16=0/1 350, 26-27=0/251, 4-26=0/1 339, 5-29=-4635/592, 29-30=-4588/587, 8-30=-4635/589, 19-20=-291/26, 24-26=011 597, 23-24=-377/0, 21-24=-936/182, 16-18=0/1 580, 17-18=-706/0, 17-20=-1 82/985, 3-26=-858/641, 26-28=-272/1641, 10-16=-862/668, 13-16=-393/1678, 6-29=-28/323, 7-30=-30/320 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108niph; TCDL=6.Opsf; BCDL=6.0ps% lh=25ft Cat. 11; Exp C Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Extedor(2) -1-4-13 to 3-0-7, Interior(l) 3-0-7 to 20-2-0, Exterior(2) 20-2-0 to 24-2-0, Interior(l) 28-7-3 to 45-8-13 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. Joaquin Velez PE No.68182 6) Ceiling dead load (5.0 psf) on member(s). 4-5, 8-9, 5-29, 29-30, 8-30 MiTek USA, Inc. FIL Gert 034 7) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 pst) applied only to room. 23-26, 21-23, 19-21, 17-19, 6904 Parke East Blvd. Tampa FIL 33610 16-17 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) Date: 2=494,11=494. May 30,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCEPAGEMB 7473 rev. 1010312blS BEFORE USE. Design vaild for use only with MiTekO connectors. Ihis design Is based only upon pararnefers shown, and is for an Individual Wilding component, not a truss syslern. Before use. the building designer [Trust vedly the applicability of design pwarneiers and properly Incoiporcrie this design Into ]he overall building design. Bracing indk-ated Is to prevent buckling of individual truss web and/or chord members only. Additional lernporary and permanent b ing MiTek' is always required for stability and to prevent collapse with possible personal injury and property darnage. For general guidance regarding the fabricatic)n, storage. de.liv m., erection and bracing of Imsses and truss systems, soeANSWII Qually Crffedd, DSB-89 and SCSI SuldIng Component 6904 Parke East Blvd. Safety kdormallorlavallable from IFLrs Plate Institute. 218 K Lee. Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty , Ply T14165141 744031 B02 ATTIC 7 Job Reference optional) American builclers itipply, vv inter Haven, 1-- L 33MU ?J. 1,5V S Mar I I eU 10 IVII I e& INULIbLi leb, 1M. "— 1—Y OU UU-- U 10 r yu ID:Pyl2dFOWAAaLOH2p9JmQ3YzTvad-kAzqcsfOy?CYT7sFDomh9-zqQrTbXLUhID2Qp5zBOeY NOTES- 9) This truss design requires that a minimum Of 7/16" strurtUral wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 10) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE - WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 101031,2015 BEFORE USE. only Wth MiTek(S) connectors. ]his design is based only upon parameters shown, and is for an individual building component. notDesignvalidfortm iallatrusssystem. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the ove Crbuildingdesign. Bracing indicated is to prevent bucking of individual truss web and/or chord members only. Additional temporary and permanent br _Ing MiTek' Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the falbricatioR storage. delivery, erection and bracing of tiu&&-s and truss systems. seeANSUM11 Quaffly Ciftdo, DS8-89 and BCS1 Buldbig CoMponent 6904 Parke East Blvd. Saf0ty IntonnationavalloNe from Truss Plate Institute. 218 N. Lee Street. ,kilto 312, Nexandda, VA 22,114, Tarrq)a, FL 33610 Truss Truss Type Qty Ply T14165142 B03 ATTIC 2 2 Ioh Ri,f American bunaers ,uppiy, VVIFILef NdVell, rL OOOOU ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-gZ5blYhGUdSGiQ?eLDo9EP2CfeCP?L?-mWXXt zBOeW 44 7-§-2 15-0-4 20-2-0 24-2-0 29-3-12 36-9-14 1 44-4-0 45-8- 5-1-12 7-6-27-6-2 -6-2 1-12 FC-6 7-6-2 -4- SX8 8X8 6 7 Scale = 1:84.9 2 0 28 27 25 24 22 20 18 15 14 13 4x4 2x4 11 3x10 2x4 11 3x4 3x4 2x4 11 U4 6- 7 0-4 3-2 11 26-3-1122 29-3-12 37- -146 1 4-4-' 17Z6-2 0_,) 3--T-123- 1_0_ 3_1_ 3_0_0 2 Plate Offsets (X,Y)-- 0-4-0,0-3-81, [7:0-4-0,0-3-81,[16:0-2-8,0-2-8],12670-2-8,0-2-81 LOADING (psf) SPACING- 2-6-0 CS1. DEFL. in loc) I/clefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) 0.29 19 >999 360 MT20 1 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.75 Vert(CT) 0.57 19 >925 240 BCLL 0.0 Rep Stress Incr NO WB 0.62 Horz(CT) 0.14 11 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Wind(LL) 0.24 24-27 >999 240 Weight: 657 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SID No.2 *Except* TOPCHORD 3-6,7-10 2X8 SO, 240OF 2,OE, 6-7: 2x6 SP NO,2 BOTCHORD 2x4 SP No.2 BOTCHORD WEBS 2x4 SP No.3 JOINTS REACTIONS. lb/size) 2=2673/0-8-0, 11 =2673/0-8-0 Max Horz 2=-350(LC 13) Max Uplift 2=-618(LC 12), 11 =-618(LC 13) Max Grav 2=2904(LC 2), 11 =2904(LC 2) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-5699/1061, 3-4=-5043/856, 4-5=-4139/926, 5-6=0/1 201, 7-8=0/1 199, 8-9=-4135/925, 9-1 0=-5047/855, 10-11 L-5699/1061, 6-7=0/1 557 BOTCHORD 2-28=-985/5023, 27-28=-1 136/3195, 24-27=-1 163/3192, 22-24=-1 6/5183, 20-22=-1 6/5183, 18-20=-348/4449, 14-18=-960/3159, 13-14=-933/3165, 11-13=-782/5023, 23-26=-583/626 ' 21-23=-583/626, 19-21=-1223/0, 17-19=-1223/0,16-17=-529/687 WEBS 14-16=0/320, 9-16=0/1 691, 26-27=0/310, 4-26=0/1 676, 5-29_-5900/836, 29-30=-5840/829, 8-30=-5899/835, 19-20=-374/43, 24-26=0/2001, 23-24=-474/0, 21-24=-1 167/235, 16-18=0/1 976, 17-18=-880/0, 17-20=-232/1237, 3-26=-1 054/800, 26-28=-341/2116,10-16=-1057/833,13-16=-492/2161, 6-29=-44/411, 7-30=-44/405 2-0-0 oc purlins (4-10-12 max.) Switched from sheeted: Spacing > 2-0-0). Rigid ceiling directly applied or 10,0-0 oc bracing. 1 Brace at Jt(s): 6, 7, 21, 19, 23, 17, 29, 30 NOTES- 1 ) 2-p!y truss to be connected together with 1 Od (0.131 "&') nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 Oc, 2X8 - 2 rows staggered at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. ce in the LOAD CASE(S) section. Ply to2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) fa ply connections have been provided to distribute only toads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been c , 6nsidered for this design. 4) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp Q Encl., GCpi=O.l 8; MWFRS (envelope) gable end zone and C-C Extedor(2) -1-4-13 to 3-0-7, Interlor(l) 3-0-7 to 20-2-0, Exterior(2) 20-2-0 to 24-2-0, Interior(l) 30-5-4 to 45-8-13 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1 .6b plate grip DOL=1.60 5) Provide acl4quate drainage to prevent water ponding. 6), All plates are 3x6 MT20 unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Ceiling dead load (5.0 psf).on member(s). 4-5, 8-9, 5-29, 29-30, 8-30 10) Bottom chord live.load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 23-26, 21-23, 19-21, 17-19, Joaquin Velez PE No.681182 MiTek USA, Inc. FL Cort 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 mima -verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11#11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with M!Tek(5) connectors. This design is based only upon parameters shown, and is for crin individual Wilding component. not afruss system. Before use. the building designer must verify the applicability ofdesiqn parameter's and Property incorporate this design iniail-re overall acbuildingdesign. Bracing indicated is to prevent buckling of individual lruss web and/or chord members only. Additional lernryoary and permanent br ing MiTek' . is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance iegarding the fabrication. storage. delivery. erection and Lxacing of trusses and truss systems. seEANSW11 Qualffy Ciftnid, DSO-89 and 9CSi Building Component 6904 Parke East Blvd. afelyintoffnaftnavail6ble from Truss Plate institute. 218 K Lee Street, Suite 312, blexandfo. VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty , Ply T14165142 744031 B03 ATTIC 2 21 Job Reference (optional) American bUliaers zuppry, winter Haven, 1--L ddrJt5U .. — I-- I 1 1— -1 .1 1. — .—Y — --- 11 - . -I- - ID:Pyl2dFOWAAaLOH2pgJmQ3YzTvad-gZ5blYhGUdSGiQ?eLDo9EP2CfecP?L?-mWXXt zBOeW NOTES- 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=618, 11 =61 8. 12) Graphical purl representation does not depict the size or the orientation of the puffin along the top and/or bottom chord. 13) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE Designmalid to use only writh Mileke connectois. Ihis design is based only upon parameters shown, and is for an individual building component. nor NEI' a truss system. 'Before use, ]he building designer must verity, the applicability of design paramelem and property incorpora to thim'design into the overall building design. Biacing indicated is to prevent buckling of individual truss web and/or chord rnernbers only. Addiliorral temporary and peri-narient bfacing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damcioe, for general guidance regarding the fabi icalion. storage. delivery. erection and bracing of trusses and truss systems. seeAN$VMI1 Quaffly Ciffeft DSO-89 and HCS1 Ruffiding Component 6904 Parke East Blvd. Safety Informatlianovall,able from Truss Plate Instflute.. 218 N. Lee Street. Suite 312, Alexciudria. VA 22314. Tampa, FL 33610 Job Truss Truss Type Oty - Ply T14165143 744031 Cot COMMON 4 1 loh Rr.' American i3maers buppry, vvinrer MaV9H, r-L0,56OU ... — . .1 1 1 — . I .. — I —, 1— - - . . ID:Pyl2dFOWAAaLOH2p9JmQ3YzTvad-cyCLSEiXOEjzxk9OSeqdJq8XOSwXTB?HDqOeyszBOeU 1-4-0 8-2-10 15-2-0 22-1-6 30-4-0 ,31-8-0 1-4-0 8-2-10 6-11-6 8-2-10 1 1-4-0 Scale = 1:58.4 4x6 0 6.00 F12 4 3x4 = 3x8 I I 2x4 i I 5x8 2X4 11 3X4 3X8 11 0 0- -,12 8-2-10 15-2-0 22-1-6 30-0-4 31 - _0 0 J 7-10-14 6-1 7-10-14 0- 20_ Plate Offsets (X,Y)-- 12:0-0-4,Edgel, f2:0-1-4,0-0-21, L3LQ 0-3-4, 5-0-3-0,0-3-4, 6.0-0-4,Edgel,[6:0-1-4,0-0-21,[9:0-4-0,0-3-01 LOADING (psf) TCLL 20.0 SPACING- 2-0-0 Plate Grip DOL 1.25 CS11. TO 0.62 DEFL. Ver,t(LL) in 0.22 loc) 9-10 I/detl 999 Ud 240 PLATES MT20 GRIP 244/190 TCDL 10.0 Lumber DOL 1.25 BG 0.58 Vert(CT) 0.20 9-10 999 240 BCLL 0.0 BCDL 10.6 Rep Stress Incr YES Code FBC2017ITP12014 WB 0.84 Matrix -AS Horz(CT) 0.08 6 n/a n/a Weight: 148 lb FT 20% LUIMBER- BRACING - TOP CHORD 2X4 SP N0.2 TOPCHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 4-9 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 2=1297/0-3-0,6=1297/0-3-0 Max Horz 2=-216(LC 13) Max Uplift 2=-488(LC 12), 6=-567(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD , 2-3=-2024/2145, 3-4=-1419/1601, 4-5=-1419/1601, 5-6=-2024/2144 BOTCHORD 2-1 0=-1742/1732, 9-1 0=-1 735/1729, 8-9=-1769/1729, 6-8=-1 776/1732 WEBS 4-9=-1 129/787, 5-9=-663/800, 5-8=-362/291, 3-9=-663/800, 3-1 0=-362/291 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=1,40mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf, h=25ft; Cat. 11; Exp C; Encl., GCpi=O.l 8; MWFRS (envelope) gable end zone and C-C Exterior(2) -1-4-13 to 1-7-10, Interior(l) 1-7-10 to 15-2-0, Exterior(2) 15-2-0 to 18-2-6 zone;'canti I ever left and right exposed ; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been ' designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=488,6=567. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Veiez'PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARKING- Verify design Parameters and READ NOTES ON THIS AND INCLUDED MffEK I REFERANCE PAGE M11-7473rev. 1010312015 BEFORE USE. oil" sign is based only upon parameters ShoWn. and is for (in ind[vidual building component notDesignvalidforuseonlyWthMiTek(D connectors. This dest a truss system. Before use, ]he building designer must verify the applicability of design parameiers and p[operly incorporale this design into the overall buildingdesign. Bracing Indicated isto prevent buckling ofindividual 1russwelband/or chord members only. Addiii6nalle.rfiporaryindperrn inentbrcr-1r)g Welk' is always required for stability and to prevent collapse with possible personal injury and properly darnage. For general guidance regaiding [he I, fabrication. storage. delivery, erection and bracing of trusses and truss systems. seeANSLIM11 Quaffly Criteria. DSB-89 and BCS1 Building Compone 1 6904 Parke East Blvd Safety Informatidnavallablo from IFUSS Note Institute, 218 N. Lee Street, Suite 312, Nexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type Oly Ply T14165144 744031 CO2 GABLE Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 8.130 s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:22:09 2018 Page I ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-YKK5swkn.YryhB2JPa3t5PFDusFgxxDhahBVIOlzBOeS 4-01 8-2-10 22-1-6 30-4-0 31-8-01- 8-2-10 M-0 i i11-4_0 '1_6 6-11-6 B-2-10 Scale = 1:58.0 4x6 — 6.00 F1 _2 0 28 27 26 25 24 23 22 21 20 19 18 17 `16 15 14 13 12 11 10 9 8 4x4 = SX8 — 4x4 02 2 8-2-10 15-2-0 22-1-6 30-0-4 A07-10-14 6-11-6 1 6-11-6 7-10-14 3-121% — Plate Offsets (X,Y)-- 3:0-3-0,0-3-41, [5:0-3-0,0-3-4], [18:0-4-0,0-3-01 LOADING (pst) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.53 Vert(LL) 0.01 57 630 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.33 Vert(CT) 0.01 57 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.38 Horz(CT) 0.01 6 ri/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -AS Weight: 251 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. All bearings 29-8-8. lb) - Max Horz 2=-216(LC 13) - Max Uplift All uplift 100 lb or less at joint(s) 27, 10, 9 except 2=-1 26(LC 13), 18=-246(LC 12), 13=-262(LC 13), 23=-278(LC 12), 6=-104(LC 13), 28=-204(LC 12), 8=-243(LC 13) Max Grav All reactions 250 lb or less at joint(s) 6, 6, 19, 20, 21, 22, 24, 25, 26, 27, 28, 17, 16, 15, 14, 12, 11, 10, 9, 8, 6 except 2=315(LC 1), 18=490(LC 1), 13=401 (LC 24), 23=390(LC 23), 2=315(LC 1) FORCES. (11b) - Max. Comp./Max. Ten. - All forces 250 (11b) or less except when shown. TOPCHORD 3-4=- 145/271, 4-5=- 145/282 WEBS 4-18=-341/238,5-18=-125/272, 5-13=-394/345, 3-18=-157/301, 3-23=-384/318 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpj=O.l 8; MWFRS (envelope) gable end zone and C-C Comer(3) -1-4-13 to 1-7-10, Exterior(2) 1-7-10 to 15-2-0, Comer(3) 15-2-0 to 18-2-6 zone; cantilever left and right exposed ; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 10, 9 except at=lb)2=126,18=246,13=262,23=278,6=104,28=204,8=243,2=126,6=104. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: May 30,2018 WARNING- Verify af..I_q parameters and READ NOTES ON THIS AND INCLUDED MfTEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Milekaconnectors. Ws design is based only upon porornelets shown, and Is for an individual building component not BEE" a truss system. Before use, the building designer must verify the applicability of design paramoieis and properly Incotporale this design Into the overall IndlVidUal ituss rnembers only. Additional temporary and petmanent bracing MiTek' building design. Bracing Indicated is to prevent txickling Of web and/or chord is always required for stalbility, and to prevent collap6e with possible personal injury and property damage. Lot general guidance regaiding the 6904 Parke East Blvd. fabilcatioR storage, delivery, erection and biacing of trusses and truss systems. seeAALVWI1 Quailly Crftda, DSB-89 and 8CS1 BufldbIg ComponOnt Tampa, FL 33610ScdbtyInformatiortavailallofromTrussPtaleInstitute. 218 N. Lee Street. uite 312, Nexandria. VA 22,314. Job Truss Truss Type Qty Ply T14165145 744031 DOI GABLE 1 1 Lb Reference (optional) American bunaers ouppy, vv inter riaven, r L 0,500V — — -1 1 . — I 1— . — I --- I— — ly ID:Pyl2dFOWAAaLOH2pgJmQ3YzTvad-VjSsHbll4TCPQLTnhUvZUgiFs3PHP88t8S-r5dzBOeQ 4-1 6-0-0 12-0-0 18-0-0 24-0-0 '-4-1116-0-0 6-0-0 6-0-0 1-4_0I- _4 0 4x6 — 4 3x4 OX4 — I.". I I — 23 22 21 20 19 IS 17 16 15 14 13 12 11 10 9 8 3x4 3x4 = 3X4 11 Scale = 1:49.9 8-0-0 8-0-0 16-0-0 8-0-0 24-U-U 8-0-0 Plate Offsets (X,Y)-- 4:0-2-0,0-0-81,[12:0-1-8,0-1-81,[19:0-2-0,0-0-7] LOADING (pst) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.50 Vert(LL) 0.00 6-8 999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.15 VetI(CT) 0.01 6-8 999 240 BCILIL 0.0 Rep Stress Incr YES WB 0.26 Horz(CT) 0.00 6 n/a, n/a I4CDL 10.0 Code FBC2017[TP12014 Matrix-S Wind(LL) 0.01 2-23 999 240 Weight: 183 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 OTHERS 2x4,SP No.3 REACTIONS. All bearings 24-0-,0. lb) - Max Horz 2=-I 75(LC 17) Max Uplift All uplift 100 lb or less at joint(s) 22, 23, 9, 8 except 2=-146(LC 12), 12=-363(LC 13), 19=-395(LC 12), 6=- 1 78(LC 13) Max Grav All reactions 250 lb or less at joint(s) 15, 16, 18, 20, 21, 22, 23, 14,13, 11, 10, 9, 8 except 2=300(LC 23), 12=530(LC 1), 19=530(LC 1), 6=300(LC 24), 6=294(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-12=-251/183, 5-12=-366/470, 4-19=-251/186, 3-19=-366/470 NOTES- 1) Unbalanced root live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Corner(3) -1-4-13 to 1-7-3, Exterior(2) 1-7-3 to 12-0-0, Corner(3) 12-0-0 to 15-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSVTPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated- 5) Gable studs spaced at 1-4-O.oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 23, 9, 8 except at=lb) 2=146,12=363, 19=395, 6 178. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: May 30,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITFKREFERANCE PAGE UH-7473mv. 1010312015 BEFORE USE. Design valid for use only with M!TekO connectors. this design Is based only upon parameters shown, and is for an individual building component not a truss systern. Before use. the building designer must vedfv the applicability of design parameters and property incorp6tate this design into the overall building desigm Bracing indicated is to prevent buckling of individual truss wet) arid/or chord rnernbers only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For qeneral.uidance regarding [hegCSISuOdingComponent 6904 Parke East Blvd. fabrication. storage. delivery. erection and bracing of trusses and truss systems. seeANSL47PI1 Qualify Crillieda, DSB-89 and B Ta FL 33610 Safety informatioricivailable ITOrn IRM Plate Institute. 218 N. Lee Slreet.SLflte 312. Alexandria. VA 22314. mpal Job Truss Truss Type City Ply T14165146 744031 D02 Common 10 1 Job Reference optional) American bunciers buppry, vvinier Haven, l--L JJUdU 0. iju 6 Mai I I Zu 10 ]VII I elk HiLlubtueb, Inc. Ywuu Ividy — -,-ie -. —ye , ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-zvOEVxmfrmKG2V2—FBQoOurShTco8bOON6jPd4zBOeP 6-0-0 i 12-0-0 1 18-0-0 1 24-0-0 25-4-0 6-0-0 6-0-0 1 6-0-0 6-0-0 i Scale = 1:43.5 4x4 4 3x4 = 3x4 = 3x4 — 3x4 = 3x4 — 16-0-0 1 24-0-0 8-0-0 LOADING (psf) SPACING- 2-0-0 CS11. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL) 0.15 8-16 999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.64 Vert(CT) 0.26 8-10 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.26 Horz(CT) 0.05 6 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -AS Wind(LL) 0.09 10-13 999 240 Weight: 111 lb' FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1044/0-8-0,6=1044/0-8-0 Max Horz 2=1 75(LC 16) Max Uplift 2=-396(LC 12), 6=-396(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (1b) or less except when shown. TOPCHORD 2-3=-1 679/589, 3-4=-1 498/578, 4-5=-1 498/578, 5-6=-1 679/589 BOTCHORD 2-1 0=-564/1465, 8-1 0=-216/957, 6-8=-414/1465 WEBS 4-8=-253/565, 5-8=-368/366, 4-1 0=-253/565, 3-1 0=-368/366 NOTES- 1 ) Unbalanced roof live loads have been considered for this, design. 2) VVind:,ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opst; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., Gcpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) -1-4-13 to 1-7-3, Interior(l) 1-7-3 to 12-0-0, Exterjor(2) 12-0-0 to 15-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=396,6=396. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 112" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.681182 MiTek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 AL WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE Design valid for use. only with Milek(FD connectors. This design is based only upon parameters shown, and is for an individual Wilding component not a truss sysiern. Before use, ]he building designer must verity the applicability of design parameters and properly incorpoicrie this design into the overall building design. Bracing indicated is to prevent buckling ofindividual truss web and/or chord ineinters only. Additional lemporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 6904 Parkefabrication. storage. delivery. erection and bracing of trusses and truss systems, seeANSV7Pil Qualify Criteria, DSB-89 and BCS1 Buldling Component East Blvd. Sofetylififonnationavoilonle tiorn Truss Plate Insfilute, 218 N. Lee Street, Suite, 312, Alexandria. VA 22314, Tampa, FL 33610 Job Truss Truss Type oty'. Ply T14165147 7440311 D03 GABLE Job Reference (optional)' American Builaers vvinier Haven, t-1-33MU .. I — --. . . 1. -... .1 -1. 11 — —1y ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-vl8 wdowNOa—HpBMMcSG5JwnuGlUcZ—JqQCWhyzBOeN 4-0 1 10-0-0 4-00-0 16-0-0 22-0-0 28-0-0 1-4_0 10-0-0 4 _0 2-0-0 6-0-0 6-0-0 Scale = 1:50.7 n ql 0 44 13 4 22 4521 46- 3x4 3x4 3x4 3x4 3x4 — 4-4-8 LOADING (psf) TCLL 20.0 TCDL 10.0 BCLL 0.0 BCDL 10.0 LUMBER - TOP CHORD 2X4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 1Z_V_U 7-7-8 7-8 7_Q SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud Plate Grip DOL 1-25 TC 0.38 Vert(LL) 0.13 18-20 999 360 Lumber DOL 1.25 BC Vert(CT) 0.14 18-20 999 240 Rep Stress Incr YES WB 0.06 Horz(CT) 0-01 16 n/a n/a Code FBC2017/-FP12014 Matrix -AS Wind(LL) 0.06 20-40 999 240 BRACING- 16 ' n 14 6 3x4 PLATES GRIP' MT20 244/190 Weight: 176 lb FT = 20% TOPCHORD Structural wood sheathing directly applied. Except: 1 Row at midpt 6-13 2 Rows at 1/3 pts 13-16 6-0-0 oc bracing: 4-5 BOTCHORD Rigid ceiling directly applied. Except: 3 Rows at 1/4 pts 34-40 JOINTS I Brace at Jt(s): 13, 12, 10 REACTIONS. All bearings 4-8-0 except at=length) 16=6-8-0, 17=0-3-8. 11b) - Max Horz 2=2,19(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 16, 4, 17 except 2=-1 34(LC 12), 21 =-530(LC 12), 22=-427(LC 1) Max Grav All reactions 250 lb or less at joint(s) 16, 4, 4, 22, 17 except 2=276(LC 1), 21 =968(LC 1), 2=276(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TORCHORD 2-3=-253/75 BOTCHORD 2-22=-259/265, 21-22=-259/265 WEBS 3-21=-280/199 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE -.10; Vult=140mph (3-second,gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.1 8; MWFRS (envelope) gable end zone and C-C Extedor(2) -1-4-0 to 1-8-0, finterior(l) 1-8-0 to 5-11 -1 zone;C-C for members I and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for Wind loads in the plane of the truss only, For studs exposed to wind (normal to the face), see Standard Indus" Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4).All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 4, 17 except Jt=lb) 2=134, 21=530, 22=427, 2=134. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. MiTek USA, Inc. FIL Cert 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: May 30,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MfTEK REFERANCE PAGE U11-7473 rov..1"3,2015 BEFORE USE. Design valid for rise only with MiTek0 connectors. rhis design is based only upon parameters shown, and is for (in individual building component. not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate, this design into the overall ckbuildingdesign. Bracing indicated is to prevent buckling of individual truss web and/or chord mernt).ers only. Addiflonal temporary and permanent br Jng MiTek* Is always required, for stability I and to prevent collapse wilt) possible personal injury and property damage. For general guidance regarding the 6904 Pa'rke East Blvd. fabilcation, storage. delivery. erection and bracing of trtrsses and truss systems. seeANSL,7pil Quality Cffledi DS8.89 and BCSI Buflding Component Tarrpa, FL 33610 Safely Infalmoiffafinvailalble from TrUSIS Plate, Institute, 218 N. Lee Street, Suite, 312, Alexandda. VA 22314. Job Truss Truss Type Qty Ply T14165148 744031 D 04 Common 3 1 1 Job Reference (optional) American burners buppry, vvinter "aven, r-L 500OU 1-4-0 6-1-13 6-1-13 0 I I — I -1 1 — --l—, I.— — — .. ly — . - — ID:Pyl2dFOWAAaLOH2p9JmQ3YzTvad-NUhN7zoYBhirvzmZwJ—VeWTrzgeELyHS34y3EPzBOeM izi-0-0 22-0-0 7-10-3 8-0-0 4x6 — 6.00 F1 2 3x4 2x4 11 5X8 I. 5x8 STP 3x4 Scale: 114"=1' i 1, 3 i 7-10-3 8-0-0 Plate Offsets (X,Y)-- [6:Ec1ge,0-1-12E8:0-4-0,0-3-0j LOADING (psf) SPACING- 2-0-0 CS1. DEF in Ioc) I/defl Ud PLATES GRIP TCLL 20 Plate Grip DOL 1.25 TC 0.81 Vert(LL) -0 08 7-8 >999 360 MT20 244/190 TCDL 10 Lumber DOL 1.25 BC 0.66 Vett(CT) -0.17 7-8 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.31 Horz(CT) 0.03 7 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -AS Wind(LL) 0.07 9-12 >999 240 Weight: 115 lb FT = 20% LIUMBER- BRACING- TOPCHORD 2x4 SP.No.2 TOPCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORb 2x4 SP No,2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SID No.3 WEBS 1 Row at midpt 3-8 REACTIONS. (lb/size) 2=961/0-8-0,7=871/0-8-0 Max Horz 2=325(LC 12) Max Uplift 2=-382(LC 12), 7=-265(LC 12) FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (11b) or less except when shown. TOPCHORD 2-3=-1 538/555, 3-5=-859/357, 5-6=-853/368, 6-7=-798/394 BOTCHORD 2-9=-688/1339, 8-9=-688/1339 WEBS 3-9=0/285, 3-8=-739/494, 5-8=0/356, 6-8=-230/639 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) -1-4-13 to 1-7-3, Interior(l) 1-7-3 to 14-0-0, Exterjor(2) 14-0-0 to 17-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOI-1.60 3) This -truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=382, 7=265. - 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. FIL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED UITEKREFERANCE PAGE M11-7473rev..1aV312015 BEFORE USE. Design valid for use only vAth MiTek(D conneclors. This design is based only upon parameters shown, and is for an individual building,6omponerfl, not a truss system. Before use, ]he building designer must verify the applicability of design parameiets and properly incorporate this design into the overall Additional temporary and permai rent lorcr-ing MiTek.' building design. Narcing indicated is to prevent buckling of individual truss web,and/or chord rnernbers only. is always required,for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the 6904 Parke East Blvdfabrication. storcrJe; delivery. orecilion,and bracing of trusses and truss systems, seeANSLMjj Quailly Crilledd, DSO-89 and BCSI Buffaling Componont Tampa, F L 33610 Safety Wormallonavoilable from truss Plate. Insfitute. 218 N. Lee Street Suite 312, Nexandrio, VA 22314. Job Truss Truss Type Qty Ply T14165149 744031 D05 GABLE 1 1 Job Refer .. e (optional) American buimers z uplpty, VVIFULF rldVerl, rL OOOOU .. I — -- I I — I .— . — .— —YID:Pyl2dFQWAAaLOH2p9JmQ3YzTva-r FIKJp u?qi'7Li'Ul'k'BkOOw4O94QQclkhenirzBOeL 4-1 1 5-6-0 14-0-0 1 16-6-0 2-,0-001- L-0-0 i I t_ 1-4_0 5-6-0 11 . o 3-0-0 2-6-0 4x4 = 6.00 F1 2 6 3x4 -1 Scale = 1:48.9 3 1.5x8 STP 28 2 M 0 16 Is 31 14 12 3x4 3x4 — 3x4 1.5x8 STP 3x4 5X8 7-4-0 14-0-0 1,4-8-0 22-0-0 7-4-0 6-8-0 7-4-0 Plate Offsets (X,Y)- [9:0-1-3,0-1-01, fl2:0-8-0,0-1-41 LOADING (psf) SP I AICING- 2-0-0 CS11. DEF in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.80 Vert(LL) -0.11 14-16 >999 360 MT211 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.55 Vert(CT) -0.20 14-16 >999 240 BCLL, 0.0 Rep Stress Incr YES WB 0.19 Horz(CT) 0.04 12 n/a . n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -AS Wind(LL) 0.08 16-27 >999 240 Weight: 157 lb FT 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 *Except* JOINTS 1 Brace at 9, 7 12-13: 2x4 SP No.2 OTHERS 2x4 SID No.3 REACTIONS. (lb/size) 2=962/0-8-0,12=869/0-8-0 Max Horz 2=323(LC 12) Max Uplift 2=-381 (LC 12), 12--262(LC 12) FORCES. (11b) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1 532/569, 3-5=-1371/552, 5-7=-1 137/457, 7-9=-1 141/458, 9-1 1=-1 170/483, 11 -12=-1 1711485 BOT CHORD 2-16=-703/1334, 14-16=-396/893, 12-14=-460/1190 WEBS 3-16=-312/319, 5-113=220/500, 5-14=-1 05/382 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi_O. 18; MWFRS (envelope) gable end zone and C-C Exterlor(2) -1-4-0 to 1-8-0, Interior(l) 1-8-0 to 14-0-0, Exterior(2) 14-0-0 to 17-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads 'in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Indus" Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 pst bottom -chord live load nonconcurrent with any other live loads. 7) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide I will fit between the bottom chord and any other members, with BCDL — 10.Opst. 8) Provide . 1 mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 381,12=262. 9) This truss design requires that a minimum of 7/16" structural.wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 10) Graphical purlin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord. Joaquin Velez PE No 68182 MiTek USA, Inc. Fl. Cort 6634 6004 Parke East Blvd. Tampa FIL 33610 Date: May 30,2018 Me—, MMZ WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015BEF ' ORE USE. Design valid for use only With MiTeke connectors. This design is based only upon parameters shown. and is for an Individual tAillding component. not a truss system. Before use, ]he building designer must veilfy the applicability of design parameters arid property incort ,orate this design into the overall building design. Bracing indicated is to pr!avent bucking of Individual truss web and/or chord members only. Addilional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the f6brication, storage,.dellvery. erection and bracing Of trusses and 1111s Systems. se.eANSUMII Qually Criii DSB-69 cmd,BCS1 Ruffiding Component 6904 Parke East Blvd. Safetykdonnofionavallable, from Truss Plate Institute, 218 N. LOEI Stleet,SUlte 312, Nexondria. VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply T14165150 744031 D06 Common 7 1 Job Reference (optional) American L5uvoersjuppiy, winier maven, r-L,5,5t5?JU y ID:Pyl2dFOWAAaLOH2p9JmQ3YzTvad-Jtp7YfqotJyZ8Gwx2kOzjxYJNUMTpsbIWORAIHzBOeK 5-6-0 11-0-0 16-6-0 22-0-0 23-4-0 0 5-6-0 5-6-0 5-6-0 5-6-0 1-4-0 Scale = 1:40.1 31 4x4 — 4 3x4 = 3X4 = JX4 = 3x4 --. 7-4-0 14-8-0 22-0-0 7-4-0 7-4-0 7-4-0 1-4,0-0-21 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.30 Vert(LL) 0.10 8-10 999 360 TCDL 10-0 Lumber DOIL 1.25 BC 0.55 Vert(CT) 0.18 8-10 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.20 Horz(CT) 0.04 6 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -AS Wind(LL) 0.07 10-13 999 240 LUMBER- BRACING - PLATES GRIP MT20 244/190 Weight: 102 lb FT = 20% TOPCHORD 2x4 SP No.2, TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=964/0-8-0, 6=964/0-8-0 Max Horz 2=162(LC 12) Max Uplift 2=-368(LC 12), 6=-368(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (11b) or less except when shown. TOPCHORD 2-3=-1 5311540, 3-4=-1 367/532, 4-5=-1 367/532, 5-6=-1 531/540 BOTCHORD 2-1 0=-512/1336, 8-1 0=-1 95/875, 6-8=-380/1336 WEBS 4-8=-228/513, 5-8=-333/333, 4-1 0=-228/513, 3-1 0=-333/332 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) -1-4-13 to 1-7-3, Interior(l) 1-7-3 to 11-0-0, Exterior(2) 11-0-0 to 14-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 5) Provide mechanical connection,(by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=368,6=368. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 112" gypsum I sheetrock be applied directly to the bottom chord. JoaquinVelez PE No.68182 MiT.ek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: May 30,2018 WARNING -Verify design pammeters and READ NOTES ON THIS AND INCLUDED MtTEKREFERANCE PAGE 11111-7473rev. 1010312015 BEFORE USE. Aers shown. and is for an individual building component, notDesignvalidforuseonlywithMITek6connectors. this design Is based only upon pararne a truss system. Before use. the building designer must verity the applicability of design parameteis and properly incorporate this design inio the overall buildingdesign. Nacing indicated is to prevent buckling of individual truss web and/or chord members only. Addilionaltemry)r(irymdperrficineriltx',Y-ing 'MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. for general guidance regarding the fabfication. storage. delivery, erection and bracing of trusses and truss systems. soeANSMI1 Quality Crfledd. DS8-89 and 9CS1 Buillding Component 6904 Pafke East Blvd. Safety kdannaflotiavallablo kern truss Plate Institute, 218 K Lee Sifeet, Suite 312, Alexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type City Ply T14165151 744031 D07 GABLE Job Reference (optional) American bunciers buppry, vv inter NaVLH, r L J606U .. — . -1 1 . -. M, I — -- — . y ID:Py]2dFQWAAaLOH2p9JmQ3YzTvad-GFxtzLr2BwDGNa4K992RoMedxH8oHml2-iwHNA7BOeI 1-4-0 5-6-0 11-0-0 16-6-0 22-0-0 23-4-0 1-4-0 5-6-0 5-6-0 5-6-0- 5-6-0 1-4-0 Scale = 1:43.6 44 — 4 JX4 = 21 20 19 18 17 16 15 14 13 12 11 10 9 8 .3x4 3x4 — 7-4-0 14-8-0 22-0-0 7-4-0 7-4-0 7-4-0 Plate Offsets (X,Y)-- [4:0-2-0,0-0-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.43 Vert(LL) -0.00 2-21 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.11 Vett(CT) -0.01 2-21 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.20 Horz(CT) 0-00 6 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix-S Wind(LL) 0.01 2-21 >999 240 Weight: 159 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc.bracing. WEBS 2x4 SP No.3 OTHERS 2x4 SP. No.3 REACTIONS. All bearings 22-0-0. Max Horz.2=162(LC 12) lb) Max Uplift All uplift 100 lb or less at joint(s) 20, 21, 9, 8 except 2=-146(LC 12), 11 =-329(LC 13), 18=-358(LC 12), 6=- 1 75(LC 13) Max Grav All reactions 250 lb or less at joint(s) 14, 16, 17, 19, 20, 21, 13, 12, 10, 9, 8 except 2=295(LC 23), 11 =487(LC 1), 18=487(LC 1), 6=295(LC 24), 6=291 (LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (11b) or less except when shown. WEBS 5-11 =-336/439, 3-18=-336/439 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2).Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl_ GCpi=0.18; MWFRS (envelope) gable end zone and C-C Comer(3) -1-4-13 to 1-7-3, Exterior(2) 1-7-3 to 11-0-0, Comer(3) 11-0-0 to 14-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPl 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 21, 9, 8 except Ot=lb) 2=146, 11 =329, 118=358, 6=1 75. Joaquin Velez PE No.68182, MiTek USA, Inc. FIL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: May 30,2018 WARNING- Vefify design param-tem and READ NOTES ON THIS AND INCLUDED MtTEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with WOO connectors. This design Is based only upon parameters shown. and is for an individual building component not a truss system. Before use, the building designer rnust verify file applicability of design pararnefers and properly incorporate this design into the overall buildingdesign. Racing indicated Is to prevent buckling ofindividual truss web and/or chord members,prily. Add! Ilonat temporary and porn tanent bracing MiTeW Is always, required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regctrcliug 'he int 6904 Parke East Blvd. fabrication. storage. delivery, erection and bracing of trussesand trusssystems. see-ANSUM11 QualffyCrillsida, DSB.89 and 18CSI SuffdIng.Compond ScifetyinformcificinavallaNe from Trims Plate Institute. 218 N. LooStreer. Suitc,312. NexandrialVA22314. Tampa, FL 133610 Job Truss Truss Type Q ty ply T14165152 744031 E01 MONOPITCH 1 Job Reference (optional) American t3unaers 6uppry, winier tiaven, 1- L 66MU 0. JJU S P/lar I I ZU 10 IVII I UK I I 1UUb11 I eb, I I 1U. VVeU IVIdY JU UU.e.V V 10 r-dye I ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-kSVFAgsgyEL7?kfWjtZgLaAh7hK?OA2BCMfqvczBOeH 1 2 12-0-0 19-4-8 I i -4-824-3'-_2 5-0-14 7 0 44 = 11 2x4 11 3x4 = 2x4 11 5 3X8 = 2x4 = 1 b C? 9 Scale = 1:57.7 6-11-2 12,0_0 13-8-0 19-4-8 2 1 91 4-1-2 14 1-8-0 5-8-8 Plate Offsets (X,Y)-- [2:0-0-1,0-2-0],[2:0-0-8,Edge],-[qlO-1-0,0-_1-1_2L[6:0-4-8,0-1-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) -0.13 2-9 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.75 Vert(CT) -0.26 2-9 >842 240 BCLL 0.0 Rep Stress Incr YES WB 0.41 Horz(CT) 0.15 15 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -AS Wind(LL) 0.23 2-9 >963 240 Weight: 123 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 *Except* TOPCHORD Structural wood sheathing directly applied, except end verticals. 1-3: 2x6 SP No.2 BOTCHORD Rigid ceiling directly applied. BOTCHORD 2x4 SP No.2 *Except* WEBS 1 Row at micipt 5-15,4-6 2-11,12-13: 2x4 SP No.3 WEBS 2x4 SP No.3 REACTIONS. Qb/size) 1=753/0-8-0, 15=744/Mechanical Max Herz 1 =584(LC 12) Max Uplift 1=-225(LC 12), 15=-480(LC 12) FORCES. (11b) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-467/0, 2-3=-1 462/420, 3-4=-856/186, 6-15=-744/480 BOTcHoRD 2-9=-855/1319, 7-9=-855/1328, 6-7=-461f712 WEBS 4-6=-845/549, 4-7=-94/500, 3-7=-687/440 NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp, C; Encl., GCpi=O. 18; MWFRS (envelope) gable end zone and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(l) 3-0-0 to 19-2-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPl I angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 0t=1b) 1=225,15=480, 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No:68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WA RNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 111V12015 BEFORE USE. Design valid for use only with M!TekO connectors'. this design is based only upon parameters shown. and is for an indiAdual building component riot Nil" a truss system. Before use. the building designer must verify the applicability of design paramelers and properly incorporate this design inlo the overall bucki I ing individi In chord rnernbers only. Additional temporary and permanent bfac-Ing MiTek' bi Ading design. Bracing Indicated is to prevent of jal iss web and/or Is always required for stability and to prevent collapse;Mth possible personal injury and property darriage. For general guidance regarding the fabrication. storage, delivery, erection and bracing of Misses and tru%, systems. w.eANSMIJ Quaffly Ciffer1% DSB-89. and BCSI BuRdbig Component 6904 Parke East Blvd. Safety inforrinaffanovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314. Tampa, FL 336 1 10 Job Truss Truss Ty e oty Ply T14165153 744031 E02 Monopitch: 1 1 Job Reference (optional) American t3trraers,,uppry, winter Haven, FL 3:388U I B_1JV 6 Mar i i ZU18 MI I L-K inausines, Inc. vvea may ju ub:z2:zi 2uiks Fage 1 ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-Ce3eOOtJjXT—duElHa4vunjyb5kEleuLROPNR2zBOeG 7-0-11 12-0-0 19 4-8 7-0-1 1 4-11-5 7--4-8 5 3x4 2x4 11 3x4 3x4 6x6 7-0-11 12-0-0 A-1 I-r III Scale = 1:55.7 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.48 Vert(LL) 0.09 6-7 999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.49 Vett(CT) 0.18 6-7 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.37 Horz(CT) 0.03 6 n/a n/a BCDL 10.0 Code FB02017ITP12014 Matrix -AS Wind(LL) 0.11 9-12 999 240 Weight: 113 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 WEBS I Row at micipt 5-6,4-6 REACTIONS. (lb/size) 6=766/Mechanical, 2=856/0-8-0 Max Horz 2=618(LC 12) Max Uplift 6=-495(LC 12), 2=-262(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (1b) or less except when shown. TOPCHORD 2-3=-123,5/240, 3-4=-756/125 BOTCHORD 2-9=-670/1035, 7-9=-671/1032, 6-7=-401/621 WEBS .3-7=-503/331, 4-7=-93/485, 4-6=-790/511 NOTES- 1) Wind: ASCE 7-10; VLllt=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=O. 18; MWFRS (envelope) gable end zone and C-C Exterjor(2) -1-4-13 to 1-7-3, Interior(l) 1-7-3 to 19-2-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opst on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCIDL = 1 O.Opsf. 4) Refer to girder(s) for truss,to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 6=495,2=262. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 112" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. FIL Cert 6634 6,904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. lar0312015 BEFORE USE Design valid for use only with Mffek(D connectors. This design is based only upon parai neters shown, and Is foran individual building component. not NNE" a truss system. Before use. the building designer must verify the arviicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of indivIdwil truss web and/or chord unernbers only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property darnage. For general guidance regarding the fabrication, storage, delivery, ereclion and bracing of trusses and truss systems. seeANSL47PI1 Quaffly Ciffado, DSB-89 and BCSF BuffdIng Component 6904 Parke East Blvd, Safety Informationivallable from Truss Plate Institute. 218 N. Loc., Street—ciulte 312, Alexandria, VA 22314 I Tampa, FL 33610 Job Truss Truss Type Qty Ply T14165154 744031 E03 Morropitch 3 1 Job Reference (optional) American buiiaers,.uppry, winter Haven, rL JJUbU 0. IOU b Ividi 1 1 eu lo 1- 1 &K 111-11lub, 111u. vvuu IvIdy OU UU."." 'U'. -9 I ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-gqcObMuxUrbrF2pvqlc8Q?G7QV5fU5ZUgg8xzVZBOeF 2- 19-4-8 7-20-1 1 4-1 , -2, 1 7-4-8 4 3X4 2x4 11 3.4 — 1.5.8 STP 3x4 3x4 — 2 7-0-11 12-0-0 1 19-4-8 0-1--12 _,_l 5 4_1'_' 7-4-8 0 1 Plate Offsets (X,Y)-- [2:0-3-0,0-3-0] LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FB02017fTP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No2 WEBS 2x4 SP No.3 CS1. DEFL. in loc) I/detl Ud TIC 0.47 Vert(LL) 0.08 5-6 999 360 BC 0.42 Vert(CT) 0.15 5-6 560 240 WB 0.34 Horz(CT) 0.01 5 n/a n/a Matrix -AS Wind(LL) 0.13 8-12 999 240 REACTIONS. (lb/size) 1=490/0-3-0,6=771/0-8-0,5=277/MechanicaI Max Horz 1 =581 (LC 12) Max Uplift 1 =-1 72(LC 9), 6=-283(LC 12), 5=-319(LC 12) FORCES. (b) - Max. Comp./Max. Ten. - All forces 250 (lb) or Jess except when shown. TbPCHORD 1-2=-564/415 BOTCHORD 1-8=-737/425, 6-8=-726/423 WEBS 2-8=-444/224, 2-6=-470/754, 3-6=-371/196 BRACING- Scale = 1:57.7 PLATES GRIP MT20 244/190 Weight: 111 lb FT = 20% TOPCHORD Structural wood sheathing directly applied, except end verficals. BOTCHORD Rigid ceiling directly applied. WEBS 1 Row at midipt 4-5,3-5 NOTES- 1 ) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TGDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=O.l 8; MWFRS (envelope) gable end zone and C-C Exterjor(2) 0-0-0 to 3-0-0, Interior(l) 3-0-0 to 19-2-12 zone; cantilever left exposed ; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 4) Re ' fer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 1 =1 72, 6=283, 5=319. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.681182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING- Verify design parameters and READ NOTES ON THISAND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid foruse onlyAh Milek(D connectors. [hisdesign is based only upon parameters shown, and isforan individual building component. not a truss system. Before use. ffie building designer must verify the applicability of design parameters and propeily incorporate this design into the overall design. Bracing indicated is to buckling of individual truss web and/or chord members only. Additional temporary and permanentbracing MiTek' building prevent is always required for stability and to prevent collapse with poAble personal injury and properly damage. for general guidance regarding the. fabrication. storage. delivery. erection and bracing of trusses, and truss systems. seeANSLIWII Qualfly Ciftib, DSO-89 and BCS1 Buffifffig Component 6904 Parke East Blvd. Tampa, FL 33610SafetyInfatmatlarcivallablefrornTrussPlatelnsfiKite.. 218 N. Lee StroetSuite 312—Nexandflar, VA 22,114. Job Truss Truss Type city Ply T14165155 744031 Fol Roof Special 2 1 Job Reference (optional) American bunaers ouppy, vyinter maven, r-L JJbt5U b.i ju s rviar i i 2ui b mi i eK inaustries, mc. vvea may ju ub:z2:z j zui 6 Hage i ID:Pyl2dFQWAAaLOH2p9JrnQ3YzTvad-BIAOpivZF9jisBN50?7NzCoE vLYDROevKuUWXZBOeE 9-8-12 17-0-0 6-7-12 7-3-4 Scale = 1:31.0 4x6 = 3 IX4 I 5x6 11 44 16 3x8 7 4X4 6 4x4 4x4s 11 9-8-12 17-0-0 9-8-12 7-3-4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.74 Vert(LL) -0.22 6-8 >920 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.47 6-8 >423 240 BCLL 0.0 Rep Stress Incr YES WB 0.78 Horz(CT) 0.03 5 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -AS Wind(LL) 0.12 6-8 >999 240 Weight: 76 lb FT = 209/.' LUIMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 *Except* 4-5: 2x6 SP No.2 REACTIONS. (lb/size) 8=665/Mechanical, 5=665/0-3-4 Max Horz 8=-99(LC 13) Max Uplift 8=-251 (LC 12), 5=-216(LC 13) FORCES. (1b) -Max. Comp./Max. Ten. -All forces 250(lb) or less except when shown. TbPCHORD 2-3=-835/330, 3-4=-858/342, 4-5=-577/314 BOTCHORD 6-8=-779/1517, 5-6=-1 83/671 WEBS . 2-8=-1458/811, 2-6=-859/608, 3-6=0/412 NOTES - I ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=1 08mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=O. 18; MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 3-1 -0, Interior(l) 3-1 -0 to 9-8-12, Exterlor(2) 9-8-12 to 12-8-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding: 4) This truss has been designed for a 10 ' 0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical"connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 0t=lb) 8=251,5=216. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. FIL Gert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 TITM-7 WARNING- Verify design parameters and READ NOTES ONTHIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Mllek(D connectors. this design is based only upon parameters shown, and is for an individual building component not a truss system. Before use, the building designer must vedfy the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional lernporaryand permanent bfacing MiTek' Is always required for stability and to prevent collopse with possible personal injury and prol:x-rty damage. for general guldonce regarding the fabrication, storage,, delivery, erection and bracing of trusses and truss systems. seeANSMII Qualffy Criteria, DSB-89 and 8CS1 Buldhig Component 6904 Parke East Blvd. Safety Informallonivallable from Truss Plate. Institute, 218 N. leeStreet. SUlte 312, kJexanclricl VA 22314 Tampa, FL 33 1 610 Job Truss Truss Type Qty Ply T14165156 744031 F02 Roof Special 2 1 Job Reference optional) American Builders supply, Winter Haven, FL 33880 8. i 30 s lviar I i 20i8 MiTek indusiiiL5, iric. ViLd May K 06:22:24 201 a rdye I ID:Py]2dFOWAAaLOH2p9JmQ3YzTvad-cDkmO2vBOSrZULyHyiecVPLN8lgUyxkn7 c112NzBOeD 5-1-0 9-8-12 17-0-0 5-1-0 4-7-12 7-3-4 Scale = 1:31.0 4x6 6. 00 F1 _2 3 c 9 3x4 = 4x4 11 9-8-12 W-04 Q-R-IP 7-3_4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.84 Ver1(LQ -0.22 6-8 >901 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 IC 0:'7' Vert(CT) -0.47 6-8 >425 240 BCLL 0.0 Rep Stress Incr YES WB 0 52 Horz(CT) 0.02 5 rila n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -AS Wind(LL) 0.09 6-8 >999 240 Weight: 78 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No-2 TOPCHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 *Except* 4-5: 2x6 SP No.2 REACTIONS. (lb/size) 8=665/Mechanical, 5=665/0-3-4 Max Horz 8=-1 34(LC 13) Max Uplift 8=-256(LC 12), 5=-213(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (11b) or ess except when shown. TOPCHORD 2-3=-797/337, 3-4=-850/331, 4-5=-579/314 BOTCHORD 6-8=-486/1096, 5-6=-1 70/660 WEBS 2-8=-1 075/550, 2-6=-491/360, 3-6=-24/436 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL 6.Opsf; BCDL=6.opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterfor(2) 0-1-12 to 3-1-12, Interior(l) 3-1-12 to 9-8-12, Exterior(2) 9-8-12 to 12-8-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding, 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb Uplift at joint(s) except Ot=lb) 8=256,5=213. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE Noi.68182 MiTek USA, Ino. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING- Verify designpamme4ers and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. ' 10/0"015 BEFORE USE. D( sign valld for use only with Milel<0 connf.ctors. This design Is based only upon porameters shown. and is for an Individual building cornpone-nt, not MEN" a truss system, Before use. ]he building designer n iust verify the applicability of design parameleis and property tricot porate, this design Into the overall Individual truss mernbets only. Additional temporary and permanent brCicing MiTek* building design. Bracing indicated is to prevent buckling of web andlor chord is always required for stability and to prevent collapse with possible personal injury and pi operly damage. For general guidance regarding the 6904 Parke East Blvd. fabi ication. storage, delivery, erec hon and bracing of ti usses and truss systems. seeANSVMj1 Quaill Crftft DSB-89 and BCS1 Buffdtng Component Tampa. FL 33610SafetyW0111nofibl"VdIONLI from TFUSS Plate, Insh lure, 218 N Le( , Street, Suite 312, Alexandria, VA 223 14. Job Truss Truss Ty e City Ply T14165157 744031 F03 Roof Special 1 1 Job Reference (optional) American uumers z5uppiy, winter Haven, FL JJ88U 8.1 3u s mar i i ZUI 8 MI I eK mausines, Inc. vvea may 3u Ub2L2b zui ts 1-age 1 ID:Pyl2dFQWAAaLOH2pgJmQ3YzTvad-4Pl8DOwpnmzQ6VXUWQ9r2dtYri0shlWxMeNbaqzBOeC 1 6-11-12 1 9-8-12 1 17-0-0 1 Scale = 1:31.0 4x6 6-oo Fi_2 41 3X4 = 4x4 11 9-8-12 17-0-0 9-8-12 7-3-4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 1-25 TC 0.85 Vert(LL) 0.23 6-8 875 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.77 Vert(CT) 0.48 6-8 41 8 240 BOLL 0.0 Rep Stress Incr YES WB 0.97 Horz(CT) 0.02 5 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -AS Wind(LL) 0.07 6-8 999 240 Weight: 81 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 *Except* 4-5: 2x6 SP No.2 REACTIONS. (lb/size) 8=665/Mechanical, 5=665/0-3-4 Max Horz 8=-1 66(LC 13) Max Uplift 8=-265(LC 12), 5-208([_C 13) FORCES. (1b) - Max. Comp./Max. Ten. - All forces 250 (1b) or less except when shown. TOPCHORD 2-3=-775/348, 3-4=-845/316, 4-5=-581/309 BOTCHORD 6-8=-327/901, 5-6=-1 57/655 WEBS 2-8=-885/443, 2-6=-395/281, 3-6=-87/467 BRACING- TOPCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORD Rigid ceiling directly applied. NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=l 40mph (3-sec6nd gust) Vasd=1 08mph; TCDL=6.Opsf; BCDL 6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpl=0.18: MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(l) 3-1-12 to 9-8-12, Extetior(2) 9-8-12 to 12-8-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide I will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 8-265,5=208. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc'. FL Cert 6634 6904 Parke East Btvd. Tampa FL 33610 Date: May 30,2018 WARNING - Venify design parameters andREAD NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGEMII-7473 rev. 1010312015 BEFOREUSE. Design valid for use only with MffekG connectors. This design is based only upon parameters shown, and is foran individual building component not a truss system. Before use, line building designer must verify the applicability of design pararnefefs and properly incorporate this design into the overall building design. Bracing indicated Is to buckling of individual truss web and/or chord rnernbets only. Additional lenriporary and permanent bracing MiTek' prevent is always required for stabAlly and to prevent collapse \,Aih possible personal injury and property damage. For general guidance regarding the fabdcation. storage. delivery, erection and bracing of trusses and trum systems. seeANSUMII Quaffly CNeigM DSO-89 and BCS1 Suffallng Component 6904 Parke East Blvd. Safety Intonnaflonavailalble from TfUSS Plate. Institute. 218 N. Lee StreetSulte 312, Nexandria, VA 22314. Tarnpa, FL 33610 Job Truss Truss Ty e Qty Ply T14165158 744031 Got Common Structural Gable 1 1 Job Reference (optional) American bunciers buippry, winter Haven, t-L J;Jbi:5U 1 -1-4-0 1 b.i6u s rviar I I ZU1 b IVII I UK mumiries, inc. vvLu may ou uu:zz:Zo Zu 1?5 rage i ID:Py]2dFQWAAaLOH2p9JmQ3YzTvad-YbsXRkxRY45Hjf6g37g4bqQuz6TjQxf4bl687GzBOeB 11-11-0 5-11-8 1 11-4-0 Scale: 1/2"=l' 4x4 = 4 T 3x4 = 3x4 = 5-11-8 11-11-0 5-11-8 5-11-8 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCILL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.02 8-21 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.34 Vert(CT) -0.05 8-21 >999 240 BCILIL 00 Rep Stress Incr YES WB 0.21 Horz(CT) 0.01 6 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -AS Wind(LL) 0.03 8-21 >999 240 Weight: 66 lb FT 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=561/0-3-4, 6=561/0-3-4 Max Horz 2=96(LC 12) Max Uplift 2=-227(LC 12), 6=-227(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - Ali forces 250 (lb) or less except when shown. TOPCHORD 2-3=-688 601, 3-4=-581/303, 4-5=-581/303, 5-6=-6851301 BOTCHORD 2-8=- 171/580, 6-8=- 1641580 WEBS 4-8=-291/543 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL 6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=O.l 8; MWFRS (envelope) gable end zone and C-C Exteror(2) -1-4-13 to 1-7-3, Interior(l) 1-7-3 to 5-11-8, Exterior(2) 5-11-8 to 8-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSIfTPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable Studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to beating plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=227,6=227. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARMING -Verify design parametersand READ NOTESOM THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for risk- only with MiTek0 connectors. this design is based only upon parameters shown, and is for an individual building component. nor a truss system. Before use. the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated Is to buckling of individual truss web andftn chord members only. Additional temporary and permanent b(cy,-.ing MiTek' prevent is always required for stability and to prevent collcpse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and Imss systems, seeANSWIl Quality Ciffedd, DSB.89 and 8CSI Building Component 6904 Parke East Blvd. Tampa, FL 33610SafetyIntonnallonavailablefromTrussPlateInstitute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Job Truss Truss Type Qty Ply T1 4165159 744031 G02 Common 5 1 Job Reference (optional) Allielicall t5ullue[5 oupply, vv inter Haven, 1- L JJ?JZ5U 5-11-8 5-11-8 1 o.iju s mar i i LUld M1 I eK mausines, Inc. vvea may ju ub:zz:zi zuits Hage 1 ID:Pyl2dFOWAAaLOH2p9JmQ3YzTvad-loQve4y3JND8LphsdrBJ72zOXWpd9QXDpxsifizBOeA 11-11-0 13-3-0 5-11-8 i 1 1 4x4 3 Scale: 112"=1' 3x4 5-11-8 11-11-0 5-11-8 5-11-8 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCILL 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) -0.03 6-9 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.07 6-9 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.10 Horz(CT) 0.01 4 n/a n/a BCIDL 10.0 Code FBC2017/TPI2014 Matrix -AS Wind(ILL) 0.05 6-9 >999 240 Weight: 46 lb FT 20%. LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=561/0-3-4,4=561/0-3-4 Max Horz 2=96(LC 12) Max Uplift 2=-227(LC 12), 4=-227(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (11b) or less except when shown. TOP CHORD 2-3=-662i 91, 3-4=-662/291 BOTCHORD 2-6=- 110/534, 4-6=- 110/534 WEBS 3-6=0/269 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VLllt=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) -1-4-13 to 1-7-3, Interior(l) 1-7-3 to 5-11-8, Exterior(2) 5-11-8 to 8-11-8 zone;C-Cjor members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=227,4=227. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARIVING- Verify design parameters andREAD AfOT'ES ON -rHiS MD iNCLUDEo MiTEKREFERAmCE PAGE 11111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek0connectors. This design Is based only upon paianieleis shown. and is for an individual buildingoomponent, not NOR" a truss system. Before use. ]be building designer must verify the crWicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and p-ernianent bracing MiTek' Is always required for stabilily and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabiicaron storagie. delivery, erection and bracing of trusses and truss systems, seeANSY711 Quality Ciftild, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Solety Intonnaffonavailabre from Truss Plate Institute. 218 N. Lee Street Suite, 312, Ne andrla. VA 22314. Tampa, FL 33610, I Job Truss Truss Type Qty Ply T14165160 744031 G03G Common Girder 1 1 Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 5-11-8 5-11-8 8.130 s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:22:29 2018 Page 1 ID:Pyl2dFOWAAaLOH2p9JmQ3YzTvad-zAYf3lzKr?Tsa6rFIGEnCT2DVJQSd6KWHFLojbzBOeB 4x4 11 1. 11 5x6 — Scale = 1:21.9 LUS24 5-11-8 11-11-0 5-11-8 5-11-8 Plate Offsets (X,Y)-- [1:0-2-8,0-011], [3 0-2-8,0-0-1 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.93 Vert(LL) 0.14 4-6 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.66 Vert(CT) -0.19 4-8 >772 240 BCILIL 0.0 Rep Stress Incr NO WB 0.98 Horz(CT) 0.03 3 ri/a n/a BCDIL 10.0 Code FBC2017fTP12014 Matrix -MS Weight: 52 lb FT 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOTCHORD 2X6 SP 240OF 2,OE BOTCHORD Rigid ceiling directly applied or 9-0-9 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=2089/0-3-4,3=2089/0-3-4 Max Horz 1 =78(LC 8) Max Uplift 1 =-838(LC 8), 3=-838(LC 9) FORCES. (11b) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except,when shown. TOPCHORD 1-2=-3329/1338, 2-3=-3329/1339 BOTCHORD 1-4=-1 134/2942, 3-4=-1 134/2942 WEBS 2-4=-977/2570 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=O.l 8; MWFRS (envelope) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5),Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 1=838,3=838. 6) Use Simpson Strong -Tie LUS24 (4-1 Od Girder, 2-1 Od Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 2-0-12 from the left end to 9-10-4 to connect truss(es) to back face of bottom chord. 7) Fill all nail holes where hanger is in contact with lumber. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Stand'ard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pff) Vert: 1-2=-60, 2-3=-60, 1-3=-20 Concentrated Loads (lb) Vert: 4=-645(B) 9=-645(B) 1 0=-645(B) 11 =-645(B) 12=-645(B) Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: May 30,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MtTEKREFERANCE PAGE 1101-7473rev. 1010312016 BEFORE USE. Design valid for use only with MilekO connectors. This design is based only upon parameters shown, and is for an Individual building component. nor a truss system. Before use, the building designer must vedfy the applicability of design pa[ameters and properly Incorporate this design Into the overall BEE" building design. Bracing Indicated Is to prevent louckling of individual truss web and/or chord members only. Additional lernporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property daniage. For general quidance regarding the fabrication. storage, delivery. erection and bracing of lnwes and truss systems. seeANSUM11 Qualfly Ciflodd, DSB-89 and III BuBdIng Component 6904 Parke East Blvd. Safety kdonnaflariavallalble from IfLrs Plate Institute, 218 K Lee Street.Sulte 312. Nexandria. VA 22314, Tampa, FL 33610 Job Truss Truss Type Oty Ply T14165161 744031 H01 Common 6 1 Job Reference (optional) American buijaers buppry, vvirrer Haven, `-L u5MUU 4-7-4 15. 115U 6 War I I Zulu lvil I UK I I luu u I eb, Im. VVUu lVidy — -'-u '- -J , ID:Pyl2dFOWAAaLOH2p9JmQ3YzTvad-RN5lH5 yblbjCGORIzIOIgbX-jtKMnfgWv4MGlzBOe7 9-2-8 1 10-6-8 1 4x4 — 3 1-4-0 Scale = 1:22.3 0 6 3x4 2x4 3x4 4-7-4 9-2-8 4-7-4 4-7-4 LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in loc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.31 Vert(LL) 0.04 6-12 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.24 Vert(CT) 0.03 6-12 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.08 Horz(CT) 0.01 4 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -AS Weight: 37 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2X4 SP No.3 REACTIONS. (lb/size) 2=452/0-3-0, 4=452/0-3-0 Max Horz 2=78(LC 12) Max Uplift 2=-189(LC 12), 4=-189(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (11b) or less except when shown. TOPCHORD 2-3=-491/726, 3-4=-491/726 BOTCHORD 2-6=-514/395, 4-6=-514/395 WEBS 3-6=-364/203 BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied. NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VLJlt=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterlor(2) -1-4-13 to 1-7-3, Interior(l) 1-7-3 to 4-7-4, Exterlor(2) 4-7-4 to 7-7-4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Jt=Ib) 2=189,4=189. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only \,Att) MilekO connectors. This design is based only upon parameters shown, and Is for an individual building component. not a truss system. Before use, the building des4gner must verly the applicability of design paramelleis and property incorporate this design into the overall lruss rnernbers only. Addillonal fernryorary and permanent bracing MiTek' buildingdesign. Bracing indicated Isic, prevent buckling ofindividual weband/orchord is always required for stability and to pi event collaps Ie with possible personal injury and property del nage. for general guidance regarding the 6904 Parke rest Blvd. fabrication. storage, delivery. erection and bracing of liusses and lni&s systems, seemwwii ouaffly Ciftdo, DSO-89 and BCS1 BuMbig Component Tanipa, FL 33610 Safety Intannaftrilavallable from IFLMs PiCllo Insfitute, 218 N. Lee Street, SUItU312, Alexandra. VA 22,314. job Truss Truss Ty e Oty, Ply T14165162 744031 H02 Common 1 1 Job Reference (optional) American builders 6upply, winter Haven, t-L 33bb u.iju s iviar 1 1 ZU 16 MI ILK muttstues, Inc. vveu may iv vo:zz:ju zuto raye I I D:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-RN51 H5-yblbjCGQRlz]DlgbWnjslMndgWv4MGlzBOe7 4-7-4 9-2-8 4-7-4 4-7-4 4x6 = 2 a 2x4 = 2x4 — Scale = 1: 19.9 4-7-4 9-2-8 4-7-4 4-7-4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/detl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) 0.04 4-10 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.27 Vert(CT) 0.03 4-10 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.08 Horz(CT) 0.01 3 n/a n/a BCDL: 10.0 Code FBC2017fTP12014 Matrix -AS Weight: 32 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=368/0-3-0,3=368/0-3-0 Max Horz I =60(LC 12) - Max Uplift 1=-132(LC 8),3=-165(LC 8) FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (11b) or less except when shown. TOPCHORD 1-2=-5161797, 2-3=-516/797 BOTCHORD 1-4=-622/431, 3-4=-622/431 WEBS 2-4=-396/21 0 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=O.l 8; MWFRS (envelope) gable end zone and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(l) 3-0-0 to 4-7-4, Exterior(2) 4-7-4 to 7-7-4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opst on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 1=132, 3=165. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Ced 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: May 30,2018 WARNING - Verify design paraineters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGEM11-7473 rev. 10/03)2015 BEFORE USE. Design valid for use only with MiTek& connoctors. This design is based only upon parameters shown. and Is for an Individual building component. not a truss system. Before use, the building designer must verily the applicability of design parameters and property incoWrole this design Into the overall to buckling individual truss web and/or chord members only. Addilional lernporary and permanent bracing MiTek' building design. Bracing indicated is prevent of is always required far stability and to prevent collapse with possible personal Injury and property damage. For geneial guidance iegarding Me fabrication. storage. delivery, erection and bracing of trusses and truss systems. seeANS&VII Qualffy Ciffeft DSB-89 and 8C$1 Building Componont 6904 Parke East Blvd. Safety Infamnaffor"vailable from Truss Hale. Institule. 218 N. Lee Streel—Suite 312, Nexanchia. VA 22314, Tarnpa, FIL 33610 Job Truss Truss Type oty Ply T14165163 744031 H03 Common 2 Job Reference (optional) American Builders Supply, Winter Haven, IFIL 33880 8.130 s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:22:31 2018 Page 1 ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-vZfQUR?aMcjZqQ?eshGFlu7gX7Bl5EKpkZqvoTzBOe6 3-6-0 8-1-4 1 lox 3-6-0 4x4 = 3-6-0 8-1-4 2x4 — Scale = 1: 18.1 i 3-6-0 4-7-4 Plate Offsets (X,Y)-- [1:Edge,0-113LJ3:0-0-0,0-0-4],[5:0-1-12,0-0-01 LOADING (pst) TCLL 20.0 SPACING- 2-0- 0 Plate Grip DOL 1.25 CS1. TC 0.39 DEFL. in Vert(LL) 0.06 loc) I/clefl Ud 4-8 >999 240 PLATES GRIP MT20 244/190 TCDIL 10.0 Lumber DOL 1.25 BC 0.29 Vert(CT) -0.04 4-8 >999 240 BCILIL 0.0 Rep Stress Incr YES WB 0.11 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017[TP12014 Matrix -AS Weight: 34 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 3=318/0-3-0,5=318/0-6-0 Max Horz 5=-82(LC 13) Max Uplift 3=-1 46(LC 8), 5=-1 23(LC 8) FORCES. (b) - Max. Comp./Max. Ten. - All forces 250 (Ilb) or less except when shown. TOPCHORD 1-2=-360/601, 2-3=-369/581, 1-5=-303/475 BOTCHORD 3-4=-430/290 WEBS , 2-4=-279/149, 1-4=-471/295 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7710; VUlt=140mph (3-second gust) Vasd=108mph; TCDL 6.0ps1f; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Extedor(2) 0-1-12 to 3-1-12, Interlor(l) 3-1-12 to 3-6-0, Exterior(2) 3-6-0 to 6-6-0 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 3=146,5=123. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND tNCLUDEDMITEKREFERANCE PAGE M11-7473 rev. 101OW015 BEFORE USE. Design valid for use only with MiTekG connectors. This design is based only upon parameters shown. and is for an individual building component. not a truss system. Before use, the building designer must veilify the applicability of design porametefs and property incofporate this design Into the overall Not building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible peisonal Injury and property damage. For general guidance regarding the fabrication. storage. delivery. erection and bracing of husses and truss systems, see-ANSUMIT Quoiffy Crftd% DSB-89 and SCSI BuMcIfIng Component 6904 Parke East Blvd. Softty hdormatim-wailable from TrLrS Plate Institute. 218 N. Lee Street. suite 312. Nexciodria. VA 22314. Tampa, FL 33610 Job Truss Truss Type oty, Ply T14165164 744031 H04 Flat Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 8-130 s Mar 11 2018 Mi I eK Inclustries, Inc. Wed May ju 06:22:32 20i8 Page i ID:Py]2dFQWAAaLOH2p9JmQ3YzTvad-NIDohn?C7wrQRaZqQOnUq5gtyXYDqfgyzDZTKwzBOe5 4-0-10 8-1-4 4-0-10 4-0-10 1 3x4 — 7 2 8 3 Scale = 1:21.8 6 4 3x6 11 3x6 11 i.Sx8 STP = 4-0-10 4-0-10 8-1-4 4-0-10 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip POL 1.25 TC 0.28 Vert(LL) 0.02 5-6 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.21 Vert(CT) 0.02 5-6 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.24 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -AS Weight: 49 lb FT = 20%. LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD BOT CHORD 2x4 SP No.2 BOTCHORD WEBS 2x4 SP No.3 REACTIONS. (lb/size) 6=312/0-6-0, 4=312/0-3-0 Max Horz 6=120(LC 11) Max Uplift 6=-271 (LC 8), 4=-238(LC 8) FORCES. (Ilb) -Max. Comp./Max. Ten. -All forces 250 (11b) or less except when shown. TOPCHORD 1-6=-281/435, 1-2=-263/440, 2-3=-263/440, 3-4=-281/423 WEBS 3-5=-526/325, 2-5=-289/251, 1-5=-545/325 Structural wood sheathing directly applied, except end verticals. Rigid ceiling directly applied. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second,gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=O. 18; MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(l) 3-1-12 to 7-11-8 zone; end vertical right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 6=271,4=238. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MfTEK REFERANCE PAGE M11-7473 rev. 10ID312015 BEFORE USE. Design valid for use only with MI]ek@ connectors. this design is based only upon parameters shown, and Is for an Individual building component. not Mal" a truss system. Before use. the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall Individual truss chord rnerribers only. Addifiortul temporary and permanent brcyclng MiTek' building design. Bracing Indicated is to prevent buckling of web aridlor is always required for stability and to prevent collapse with possILAe personal injury and property damage. for general guidance regarding the fal:xIcalion, storage, delivery. erection and bracing of trusses and truss Systems, skeANS&VII Quaffly Ciffisda, DSB-89 and SCSI BuDdIng Component 6904 Parke East Blvd. Tarnpa, FL 33610 St7ftilly jn[f0IMaff0fX-1Vai10bIe from Truss Plate Institute. 218 N. Lee, Street,Sulle 312, Alexandra, VA 22314. Job Truss Truss Type Qty. Ply T14165165 744031 K01 FLAT 10 1 Job Reference (optional) American t5unaers buppry, winter maven, 1- LJJbbU 5-3-14 4x4 = 6 2x4 7 2X4 11 2 5 3x10 0. 1,5U S WWI I I ZU 10 IVII I eK I I IUU InUb, 1M. V-U IVIUY O --- .... .. Y , ID:pBo2QDQ4UzF—Agn3M51CIGzTvbv-rynAv7OquDzH3k8Oz5ljNJD?UxvvZ3k6CtJOsMzBOe4 10-7-12 1 8 5-3-14 10-7-1 5-3-14 5-3-1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/defl Ud TCLL 40.0 Plate Grip DOL 1.25 TC 0.49 Vert(LL) 0.05 5 999 360 TCDL 10.0 Lumber DOL 1.25 BC 0.18 Vert(CT) 0.08 5 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.44 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -AS Wind(ILL) 0.04 5 999 240 Scale = 1: 17.8 4x4 3 4 2x4 11 PLATES GRIP MT20 244/190 Weight: 52 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied, except end verlicals. BOT CHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 6=621 /Mechanical, 4=62 1 /Mechanical Max Uplift 6=-189(LC 8), 4=-189(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-557/234, 1-2=-1251/381, 2-3=-1251/381, 3-4=-557/234 WEBS 1-5=-352/1157,2-5=-549/274, 3-5=-352/1157 NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18- MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(l) 3-1-12 to 10-6-0 zone;C-C for members nd forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except flt=lb) 6= 189, 4=1 89. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 112" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.681182 MiTek USA, Inc. FIL Cett 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: May 30,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MfTEKREFERANCE PAGE M11-7473 rev. 10103J2015 BEFORE USE. Design valid for use only with M!TekO connectors. This design is based only upon parameters shown, and is for an individual building component. not a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building desigrf. , Bracing Indicated Is to buckling ofindividual truss web and/of chord rnernbers only. Additional lernporary and permanent bracing MiTek' prevent Is always required for stability and to pievent collapse with poAble peisonal injury and property clainage. For general guidance regarding the 6904 Parke East Blvd. fabfication, storage, delivery. erection and bracing of trusses and truss systems. seeANS&7p11 Quaffly Ciffedd, DSB-89 and 8CS1 Bullialklig Component Tampa, FL 33610SafetyWbimattlattavallablefro)[1) Truss Plate Institute, 218 N. Lee Street. SUlte 312, Adexandda. VA 22314. Job Truss Truss Type Qty' Ply T14165166 744031 K02 ROOF SPECIAL 4 1 Job Reference (optional) American builders supply, Winter Haven, F-L 33880 8.13U s mar I I ZU16 MI I eK industries, Inc. vvect may JU Ub:ZZ:J4 eUlts Fage 1 ID:pBo2QD04UzF Agn3M51CIGzTvbv-JBLY6TISfX68hujCXppyvWlAbKDTIVgFOX2ZPOzBOe3 3-10-8 7-9-0 10-7-12 3-10-8 3-10-8 2-10-12 2x4 11 3XB 2 3x4 — 8x14 = 3x4 7 6 2x4 11 6XIS 8 4 5 12.00112 Scale = 1:18.3 C? T ': T 0 0 C? C? 3-10-8 7-9-0 8'-_9'-_00 10-7-12 3-10-8 3-10-8 1-10-12 Plate Offsets (X,Y)-- 4:0-0-4,EdgeL[5L.0-2-_0,EdRe [ -2-8,0-1-41J, 6:0 LOADING (psf) SPACING- 2-0-0 CS1. DIEFL. in loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.25 TC 0.46 Ven(LL) -0.05 6-7 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.29 Vert(CT) -0.08 6-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.40 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017[TP12014 Matrix -AS Wind(LL) 0.04 6-7 >999 240 Weight: 52 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOPCHORD Structural wood sheathing directly applied, except end verticals. 3-5: 2x6 SP No.2 BOTCHORD Rigid ceiling directly applied. BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (Jb/size)' 8=626/MechanicaJ, 5=592/MechanicaJ Max Horz 8=-9(LC 8) Max Uplift 8=-1 95(LC 8), 5=-213(LC 8) FORCES. (11b) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-958/348, 3-4=-596/197 BOTCHORD 7-8=-357/1118, 6-7=-357/1118, 4-6=-535/1552 WEBS 3-6=-1200/477, 2-8=-1200/392 NOTIES- 1 ) Wind: ASCE 7-10; Vu1t=1 40mph (3-second gust) Vasd=1 08mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0. 18; MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(l) 3-1-12 to 10-7-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 pst bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 8=195,5=213. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: May 30,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLuDEDWEI(REFEnANCE PAGE M11-7473 rev. 1010"015 BEFORE USE. Design valid for use only with M!Tekg conneciois. this design Is based only upon parameters shown, and is for an Individual building component, not a Iruss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall is to buckling iridIVIdUal truss and/or chord members only. Additional temporary and permanent bracing MiTek' building design. Bracing indicated prevent of web Is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the 6904 Parke East Blvd. Fabrication, storage, delivery, erection and bracing of truss-_s and truss systems. seeANS&7PI1 Qualility Criteria, DSB-89 and SCSI BuRdbig Component Tampa, FL 33610SafetyIntonnallianavallablefrom1russPlateInstitute. 218 N. Lee Street, Suite 312, Nexandria. VA 22314 Job Truss Truss Type city Ply T14165167 744031 Mot GABLE 2 1 Job Reference (optional) American Builders Supply, Winter Haven, I'L 33880 2-0-0 i 2_'_' LOADING (pst) TCLL 20.0 TCDIL 10.0 BCLL 0.0 BCDL 10.0 8.130 s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:22:35 2018 Page 1 ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-oKvwKp25QrE?ll IP5WLBSkIL4kcVl2OPfBo7xEzBOe2 10-4-4 10-4-4 4x4 = 3x4 = SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017ITP12014 CS1. DEFL. in (loc) I/defl Ud TC 0.48 Vert(LL) 0.02 1 n/r 120 BC 0.11 Vert(CT) 0.01 1 n/r 120 WB 0.05 Horz(CT) -0.00 9 n/a n/a Matrx-S. LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BOTCHORD OTHERS 2x4 SP No.3 REACTIONS. All bearings 10-4-4. 11b) - Max Horz 2=195(LC 8) MaxUplift All uplift 100 lb or less at joint(s) 9, 14, 13,12, 11, 10 except 2=-230(LC 8) Max Grav All reactions 250 lb or less at joint(s) 9, 14, 13, 12, 11, 10 except 2=298(LC 1) FORCES. (11b) - Max. Comp./Max. Ten. - All forces 250 (11b) or less except when shown. Scale = 1: 19.9 8 PLATES GRIP MT20 244/190 Weight: 50 lb FT= 20% Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTIES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opst; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Corner(3) -2-0-7 to 0-11-9, Exterior(2) 0-11-9 to 10-2-8 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1,.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSIITPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 bc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconCUrrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom.chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 14, 13, 12, 11, 10 except at=lb) 2=230. Joaquin Velez PE No.68182 MiTek USA, Inc. FIL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MTTEKREFERANCE PAGE M11-7473rev. IM312015 BEFORE USE. 7 Design valid for use only with MiTekO connectors. This design is based only upon parameters shown. and is for an individual building component. nor a truss system. Before use, I he building designer in usl veil fy I he applicabili ty of design par ameiets and pioperly incorporate this design Into I he overall bullding design. Bracing IndIcaled Is to buckling of individual truss web and/or chord members only: Additional lernpofary and permanent bracing MiTek' prevent Is always required for stability and to p event collapse wilh possible personal injury and properly darnage. For general guidance regai ding the fabrication, storage, delivery, erection and bracing of trusses and truss syslerns. seeANSM11 Qualfly Criteria, D$8-89 and BCS1 SuBdIng Component 6904 Parke East Blvd. Safety Intonnationavallable frorn Truss Plate Insfikite, 218 N. Lee Street. Suite 312, Nexandria. VA 22,314. Tampa, FL 33610 Job Truss Truss Type Qty, Ply T14165168 744031 M02 Monopitch 14 1 Job Reference (optional) American buimers z,uppiy, , winter Haven, I-LJJbbU u,iou s tviar i i ZU]b PA] I eK mousirres, mc. vveo may ou uo:zz:,ji) zui b --age i ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-GXTJX93jBBMswBtbfEsQ?xrVA8sfmQEYurXgThzBOe1 7-6-1 10-4-4 7-6-1 2-10-3 Plato Offsets LOADING (psf) SPACING- 2-0-0 CSI DEFL. in loc) I/cletl Ud TCLL 2C ).0 1e Grip DOLpie 1 .25 TC 0.52 Vert(LL) 0.24 6 -9 519 240 TCDL 10.0 Lumber DOL 1.25 BC 0.50 Vert(CT) 0.16 6-9 777 240 BCLL 0 0 Rep St ess Incr YES WB 0.33 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Mattix-AS I LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP NO2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=543/0-3-0,5=396/0-8-0 Max Herz 2=195(LC 8) Max Uplift 2=-468(LC 8), 5=-338(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-639/807 BOTCHORD 2-6=-882/592, 5-6=-882/592 WEBS 3-6=-471/275, 3-5=-742/1 100 Scale = 1:21.2 2x4 11 4 1.5X8 STP 6x6 10-4-4 2-10-3 PLATES GRIP MT20 244/190 Weight: 45 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied, except end verticals. BOTCHORD Rigid ceiling directly applied, NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterjor(2) -2-0-7 to 1-1-0, Interior(l) 1-1-0 to 10-2-8 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed f , or a 10.0 psf bottom chord live load nonconourrent with any other live loads. 3) * This truss has been designed for a live I ' oad of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=46815=338. 5) This truss design requires that a minimurn of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. Joaquin Velez PE No.68182 MiTek USA, Inc. Fl. Cert 6634 6904,Parke East Blvd. Tampa Fl. 33610 Date: May 30, 2Q 18 WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 101031201SUEFOREUSE. DesJgn valid for rise only with Milek(D connectors. this design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, ]he bulding designer i nust veffy the applicability of design parameters and properly incorporate this design into the overall indicated is to Wokling individual truss web and/or chord nierribers only- Additional temporary and pernianent biacing MiTek' building design. Biracing prevent of is always required for stdbility and to prevent collapse with possilble personal injury and properly damage. For generaiguidance regarding the, fabrication, storage. delivery. erection and bracing of trusses and truss systems, %eeANSMIj Quaffly Ciffedd, DSB-89 and 11CSIBUMcling Component 6904 Parke East Blvd. Tampa, FL 33610SafetyIntotmatfor"vailalote ftorn Truss Plate Institule.218 N. Lee Streel,Suite 312. Nexandtio. VA 22314. Job Truss Truss Type Qtyl Ply T14165169 744031 PB1 GABLE 2 1 Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 8.130 s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:22:37 2018 Page I ID:pBo2QDQ4UzF—Agn3M51CIGzTvbv-kjOhIU3LySUjYLSnCxNfXgNnbY]oVxWj7VHD?7zBOeO 10-0-0 5-0-0 Scale = 1: 19.0 4x4 — 16 6 1 0 9 2x4 2x4 I 2x4 11 2x4 2x4 LOADING (pst) SPACING- 2-0-0 CS1. DEFL. in loc) I/clefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) 0.00 7 n/r 120 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.06 Vert(CT) 0.00 7 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.00 6 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix-P Weight: 35 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD BOTCHORD 2x4 SP No.2 BOTCHORD OTHERS 2x4 SP No.3 REACTIONS. All bearings 8-0-14. lb) - Max Horz 2=-61 (LC 13) Max Uplift All uplift 100 lb or less at joint(s) 2, 6 except 10=-135(LC 12), 8=-134(LC 13) Max Grav All reactions 250 lb or less at joint(s) 2, 6, 9, 10, 8 FORCES. (11b) -Max. Comp./Max. Ten. -All forces 250 (11b) or less except when shown. Structural wood sheathing directly applied or 6-0-0 oc puffins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1 ) Unbalanced,roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Expr C; Encl., GCpi=O. 18; MWFRS (envelope) gable end zone and C-C Exterior(2) 0-4-3 to 3-4-3, Interlor(l) 3-4-3 to 5-0-0, Exterior(2) 5-0-0 to 8-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gabfe End Details as applicable, or consult qualified building designer as per ANSI/TP1 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6 except at=lb) 10=135,8=134. 9) See Standard Industry Piggyback Truss Connection Detail for Connection. to base truss as applicable, or consult qualified building designer. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cen 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: May 30,2018 AWARMING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. laV312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an individual building component, not Nilatrusssystem. Before use, the building designer must vedfy the applicability of design parameters and properly Incorporate this design Into the ovetoll buildingdesign. Bracing Indicated is to prevent buckling of Individual Imss web andlor chord unernbers only. Additional ternporaryandpennaneni bracing MiTek' Is always required for stability and to pi event collapse with possible per sonal injury and properly damage. For general guidance regarding the fabficatioR storage, delivery, erec Non and bracing of husses and truss systems. seoANSMIJ Quaffly CrUedd, DSB-89 and SCSI BuRding Component 6904 Parke East Blvd. Safety Intatimatilariavailable from TfLM P1010 Institute, 218 N. Lee Street. Sulto 312, Nexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qy Ply T14165170 744031 P132 Piggyback 10 Job Reference (optional) American l3uilclers 6upply, winter Haven, t-L JJt5bU 0. 16U b ]Vidl I I ZVI 0 IVII I — I I I—LI I Ub, 11— V—U IV-y — —"— .— '.V ID:pBo2QDQ4UzF—Agn3M51CIGzTvbv-Cva3yq4zjmca9Vl—mfuu4MwuhycMEP2rLgOnYZzBOe? Scale = 1: 19.0 4x4 — 3 2x4 2x4 2x4 10-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.33 Vert(LL) 0.01 5 n/r 120 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.16 Vert(CT) 0.02 5 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.05 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-P Weight: 31 lb FT = 20% LIUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4'SP No.3 REACTIONS. (lb/size) 2=203/8-0-14,4=203/8-0-14,6=313/8-0-14 Max Horz 2=61 (LC 12) Max Uplift 2=-1 12(LC 12), 4=-1 24(1-C 13), 6=-54(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (11b) or less except when shown. NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VUlt=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) 0-4-3 to 3-4-3, Interion(l) 3-4-3 to 5-0-0, Exterior(2) 5-0-0 to 8-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except at=lb) 2=112,4=124. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING - Verfifydesi_qnpammeters and READ NOTES ON THIS AND INCLUDED MffEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Mllek(D connectors. this design Is based only uponparametefs shown, and Is for anincMdual building component. not nilatrusssystem. Before use, the building designer must verify the applicability of design paiarneief5and properly Incorporate this design frilolhe overall individual truss chord members only. Addilional temporary and permanent bracing MiTek' building design. Bracing indIcaled Is to prevent buckling of web and/or Is always required for stability and to prevent collapse with possible personal injury and property clarnagie. For general guidance regarding hie 6904 Parke East Blvd. fabilcation, storage. delivery, ereclion and bracing of trusses and truss systems. seeAN$&?P11 Quality CrOodd, DSO-89 and BCS1 Buflallng Component Tampa, FL 33610SafetyIntonnaftmivallalblefromTruvsPlateInstitute, 218 N. Loo Street, Suite 312, Alexandria. VA 22314, Job Truss Truss Type Q Ply T14165171 744031 PB3 Piggyback 8 1 Job Reference (optional) American Builders Supply, Winter Haven, I'L 33880 8.130 s Mar 11 2018 Mi I ek industries, Inc. Vved May 30 ub:22:j9 z01 t5 Page 1 ID:pBo2QDQ4UzF—Agn3M51CIGzTvbv-g68R9A5bU3kRnfcAKMP7caTBvL—Ozs5—apmK4OzBOe- 2-0-0 4-0-0 2-0-0 2-0-0 3x4 — 2x4 = 2x4 = SGale = 1:7.8 0 0 4-0-0 4-0-0 Plate Offsets (X,Y)-- [3:0-2-0,Eclge LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.04 Vert(LL) -0.00 4 n/r 120 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.05 Vert(CT) -0.00 4 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrx-P Weight: 10 Ito FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOTCHORD 2x4 SP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=120/2-0-14,4=120/2-0-14 Max Horz 2=22(LC 12) Max Uplift 2=-56(LC 12), 4=-56(LC 13) FORCES. (Ilb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10 Vult=140mph (3-second gust) Vasd=1 08mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. If-, Exp C; Encl., GCpi=0.18; IVIWF S (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 904 Parke East Blvd. Tampa Fl. 33610 Date: May 30,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MrFEK REFERANCE PAGE M11-7473 rev. 10VV3V20IS BEFORE USE. Design valid for use only vAth MiTek6 connectors. Ihis design is based only upon parameters shown. and Is for an Individual building cornponent. not a truss system. Before use, Ihe building designer must verify the applicability of design parameters and properly Incoiporcrie this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for slalblilly and to prevent collapse with possible peisonal injury and properly damage. For general guidance regai ding the fabrication. storage. delivery. erection and bracing of trusses and truss systems. W.EANSMIF QuOlffy C190do, DSB-89 and BCS1 BuRdlIng Component 6904 Parke East Blvd. Satoty Infoirmaffonavallable from IRM Plat(' Institute, 218 N. Lee Street.Sulte 312. AJexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type City) Ply T14165172 744031 PB4 PIGGYBACK 2 1 Job Reference (optional) American buraers buppy, winter Haven, t-L 33680 813U s Mar 11 ZU1 8 MI I eK InclUStrieS, Inc. Wert May 30 06:22:40 2018 Hage I ID:pBo2QDQ4UzF-Agn3M51CIGzTvbv-8lipNW6DFNsIPpBMu3wM9n?JOIJLIJL8pTVubszBOdz 2-0-0 4-0-0 2-0-0 2-0-0 Scale = 1:7.8 6 2x4 — 2.4 — 4-0-0 4-0-0 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (pst) I SPACING- 2-6-0 CS1. DEFL. in loc) I/clefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.06 Vert(LL) '-0.00 4 n/r 120 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.00 4 n/r 120 BCLL 0.0 Rep Stress Incr NO WB o.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-P Weight: 10 lb FT 20% LUIMBER- BRACING- TOPCHORD 2x4 SP No.2 TOPCHORD 2-0-0 oc purlins BOTCHO D 2X4 SP No,2 Switched from sheeted: Spacing > 2-0-0). BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS., (lb/size) 2=150/2-0-14,4=150/2-0-14 Max Horz 2=27(LC 16) Max Uplift 2=-71 (LC 12), 4=-71 (LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=1,08mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=O.l 8; MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Joaquin Velez PE N6.68182 M!Tek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MrrEKREFEPANCE PAGE Mit-7473'rev. 10/0 2015 BEFORE USE. Design valid for rise only with Mffek(S) connectors. this design is based only upon parameters shown. and is for an individual [AAding component. not a truss system. Before use. ]he building designer must verry lh(-,, applicability of design parameters and properly incorporate this design into lhe overall building design. Brocing indicated is to prevent buckling or individwil truss web and/or chord mernbeis only. Additional temporary and permanei it bracing MiTek' Is always required for stability and to prevent collapse \With possible personal Injuiyand prop" damage. For general guidance regarding the falrAication, storage, delivery, erection and txacing of husses and truss systems. seeANS&VIj Qually Crftda, DSB-89 and BCSI Buffafing Component 6904 Parke East Blvd. Safety Informatiom-wallable from Truss Plate, Insfilule, 218 N. ree Street, Sure 312, Nexandria, VA 22314 Tampa, FIL 33610 Job Truss Truss Type 0tv Ply T14165173 744031 RGI GABLE 1 2 Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 8.130 s Mar 11 2018 MiTek Industries, Inc. Wed May 30 06:22:42 2018 Page I ID:Pyl2dFOWAAaLOH2p9JmQ3YzTvad-4gqaoC7Un-6Oe6KI?UzqEC5ZEZvdA3ZRGn—gKzBOdx 5-3 10-7-12 g_ _ 14 i 15_"t 5-3-14 Special 4x6 = Special Special Special 4x6 1 25 26 2 27 28 3 29 30 31 5 3233 34 3x8 11 HUS26 4X8 — LUS24 LUS24 3X8 11 LUS24 LUS24 5-3-1 10-7-12 4 5-3-14 Scale = 1:54.3 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.42 Vert(LL) 0.06 5-6 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.46 Vert(CT) 0.07 5-6 999 240 BCLL 0.0 Rep Stress Incr NO WB 0.66 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix-S Weight: 398 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x6 SP No.2 TOPCHORD BOTCHORD 2x6 SP No.2 WEBS 2x4 SP No.3 *Except* BOTCHORD 1-6,3-4: 2x6 SP No.2 WEBS OTHERS 2x4 SP No.3 REACTIONS. lb/size) 6=334 1 /Mechanical, 4=2739/Mechanical Max Uplift 6=-1704(LC 4), 4=-1482(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD l-6=-2501/1219,1-2=-1 1 12/589,2-3=-1 1 12/589,3-4=-2500/1221 WEBS 11-5=-1094/2054.2-5=-2203/770.3-5=-1 11012099 Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verficals. I Rigid ceiling directly applied or 10-0-0 oc bracing. 1 Row at midpt 1-6,3-4 NOTES- 1) 2-ply truss to be connected together with 1 Od (0. 131 "x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except it noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 740; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone; Lumber DOL=1.60 plate gdp DOL=1.60 4) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Indus" Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 5) Provide adequate drainage to prevent water ponding. 6) Ali plates are 2x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 10) Refer to g1rder(s) for truss to truss connections. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 6=1704,4=1482. 12) Use Simpson Strong -Tie LUS24 (4-10d Girder, 2-1 Od Truss, Single Ply Girder) or equivalent spaced at 3-10-12 oc max. starling at 1-4-4 from the left end to 9-1-12 to connect truss(es) to back face of bottom chord- 13) Use Simpson Strong -Tie HUS26 (14-1 Od Girder, 4-1 Od Truss, Single Ply Girder) or equivalent at 3-4-4 from the left end to connect truss(es) to back face of bottom chord. 14) Fill all nail holes where hanger is in contact with lumber. 15) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 605 lb down and 193 lb up at 1-4-4, 605 lb down and 190 lb up at 3-4-4, 605 lb down and 185 lb up at 5-3-0, and 605 lb down and 190 lb up at 7-1-12, and 605 lb down and 193 lb up at 9-1-12 on top chord. The design/selection of such connection device(s) is the responsibility of others. Joaquin Velez PE No.68182 MiTek USA, Inc. FIL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 0-MIM499to"r. ... -u A WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED UtTEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only,,Ath MiTekO connectors. this design is based only uFyin parameters shown. and is for an individual building component not a truss system. Before use, the building designer must verify the applicability of design Ix.riarneiets and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web arid/or cty id members only. Additional temporary and pernriarient bracing MiTek* is always required for stability and to Prevent collapse with possible personal Injury and prop erly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSLIM11 Quality Crifferld, DS11-69 and BCS1 SuRding Component 6904 Parke East Blvd. Safety Informatilonavallable, from TIMS Plate Institute, 218 N. Lee. Street, Sulte 312, Pdexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Q Ply T14165173 744031 RG1 GABLE 1 2 Job Reference (optional) American Builders Supply, Winter Haven, FL 33880 8.130 s Mar 11 2018 Mi I eK Industries, Inc. Wed May 30 06:22:42 2018 Page 2 ID:Pyl2dFOWAAaLOH2p9JmQ3YzTvad-4gqaoC7Un-6Oe6K]?UzqEC5ZEZvdA3ZRGn—gKzBOdx LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-60, 4-6=-20 Concentrated Loads (lb) Vert: 5=-257(B) 2=-605 25=-605(F) 26=-605(F) 27=-605(F) 28=-605(F) 29=-724(B) 31 =-746(B) 32=-257(B) 34=-257(B) WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MrFEKREFERANCE PAGE UII-7473 rev. IaV312015 BEFORE USE. Design valid for use only vAth MiTekO conneclors. This design Is based only upon parameters shown, and is for an individual building component not Nil" a truss system. Before use. the building designer must verily the applicabIlity of design parai neters and properly Incotpoiate this design into the overall buildingdesign. Bracing indicated is to buckling truss web and/or chord mernbers only. Additional temporary and permanent bracing MiTek* prevent ofinclividual is always required for stability and to prevent collapse Mth possible personal injury and property clamage. For general guidance regarding the fabrication. storage. delivery, erec, Non and btacing of trusses and truss systems. seeANSLIM11 QuaW Ciftfla, DSB.89 and BCSJ SuDdIng Component 6904 Parke East Blvd. Safetybdormlaffoxivallable from Truss Plate Institute. 218 N. Lee Street, SUlte312, Nexandria. VA 22,314. Tarrpa, FL 33610 Job Truss Truss Type Qtyl Ply T14165174 744031 VTI Valley 1 1 Job Reference optional) American Builders 6upply, VVinter Haven, t-L 33?38U d.-i ju s imar 11 ZU1 6 IMI I eK maustrres inc. vveo rviay JU U0:ZZ:4Z ZU 10 f-age ) ID:Pyl2dFQWAAaLOH2p9JmQ3YzTvad-4gqaoC7Un 6Oe6KI?UzqEC5eCZOIACFRGn-gKzBOdx 2x4 11 5 9 8 7 6 2x4 2x4 11 2x4 11 2x4 11 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.10 Vett(LL) 0.00 4 rVr 120 TCDL 10.0 Lumber DOL 1.25 BC 0.04 Vert(CT) 0.00 4 n/r 120 BCLL 0.0 Rep Stress Incr. YES WB 0.10 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2017/-FP12014 Matrx-P LUMBER- TOPCHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 Sp No.3 REACTIONS. All bearings 5-5-8. b) - Max Horz,1=145(LC 12) Max Uplift All uplift 100 lb or less atjoint(s) 7, 8 except 9=-1 14(1-C 12) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 8, 9 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-274/82 WEBS 2-9=-135/341 Scale = I it 7.1 PLATES GRIP MT20 244/190 Weight: 23 lb FT = 20% BRACING- TOPCHORD Structural wood Sheathing directly applied or 5-5-8 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi 0.1 8; MWFRS (envelope) gable,end zone and C-C Comer(3) 0-7-7 to 3-7-7, Exterior(2) 3-7-7 to 5-5-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.6 0 plate grip DOL=1.60 2) Truss"clesigned for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSIITPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 8 except jt=Ib) 9=1 14. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: May 30,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473rev. 10103)201SSEFORE USE. Design valid for use only \,Ath MiTek0connectors. 1his design is based only upon parameters shown. and is torch individual building component, not a truss system. Before use, the building designer rnusl verity the applicability of design pararnelers and proporly incorporale this design into lhe overall indicated is to buckling Individual truss web and/of chord rriernbers only. Additional lernporary and permanent bracing MiTek' building design. Bracing prevent or general guidance regarding theisalwaysiectulredforstabilityandtopreventcollapse \vIth possiNe personal injury and property dainage. Forc 6904 Parke East Blvd. fabrication, storage, delivery. erection and bracing of trusses and truss systems, w-eANs&1jPjI Quaffly Ciffeft DSB-89 and BCS1 SuffdIng Component Tampa, FL 33610SafetyIntonnatillonavaiablefromRUSISPlateInsfikite, 218 N. Lee Street SLItte 312, Alexandrio, VA 22314. PLATE LOCATION AND ORIENTATION 31; Center plate on joint unless x, y offsets are indicated. Dimensions are in ft -in-sixteenths, Apply plates to both sides of truss and fully embed teeth, For 4 x 2 orientation, locate A plates 0-1/,' from outside edge of truss, This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20120 soltware or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots, Second dimension is the length parallel to slots, LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings supports) occur, Icons vary but reaction section indicates joint number where bearings occur, Min size shown is for crushing only. Industry Standards: ANSI/TP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. n 0 0 n 0 Numbering System 'A General Safety Notes 6-4-8 dimensions shown in ft-in-sixteenths Drawings not to scale) 2 3 TOP CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBEREDILETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERSILETTERS PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1 311, ESR-1 352, ESRI 988 ER-3907, ESR-2362, ESR-1397, ESR-3282 0 Of 0 a- 0 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. @ 2012 MiTek@ All Rights Reserved M ON M!Te:k WIT6 V. Fac14pprita feference Sheet: Mll-7473 rev. 10/03/2015 1 Failure to Follow Could Cause Property Damage or Personal Injury 1 . Additional stability bracing for truss system, e.g. diagonal or X-brocing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer, For wide truss spacing. individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stock materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane otjoint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber sholl not exceed 19% at time of fabrication, 9. Unless expressly noted. this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Comber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to comber for dead load deflection. 11, Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12, Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13, Top chords must be sheathed or purlins provided at spacing indicated on design, 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted, 15. Connections not shown are the responsibility of others, 16. Do not cut or alter truss member or plate without prior approval of on engineer. 17, Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance i isks. Consult with project engineer before use, 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20, Design assumes manufacture in accordance with ANSI/TPI I Quality Criteria. RECORD COPY City of Sanford Building and Fire Prevention Product Approv cification Form HISTORIC PERMtT All work must be done in strict accordance WM the 0 - llpo% Approved Certificate of AppropriatenesS Permit # # 1 8 - 2 4 9 1 Building does not approve any work outsWe this scope Permit Applicant is soley responsible for cwVliance tw x- CCProjectLocationAddress As recluired by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuildin-g.orcl. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal) 1. Exterior Doors Ro-A- 1\KX5+ Iro -LNL- Seitizs 15' Z 15-- 4 Swinging kask P'.0 TJL- SA'a L,& fj 1 .220-11 9fte" x,m5 EA,4t!N hciOr 'Pro L-tig 59,al-a-s 1 Sectional Querkerae 10cor eorp Satzuj 176 Roll Up Automatic Other 2. Windows Single Hung 1*0.) He6ze er 5olta r1L,-7--J Ma 3 5- go :5 ti I 6-V 710. Cr Casement Double Hung Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Categoryl Subcategory Manufacturer Product Description Florida Approval # including decimal) 3. Panel Walls Siding v t es A6 i Le 10 C. C&bAj?(O,#%w tzip 131,72, 1 Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underlayments mid 5 45 4yuo+ 147 7qo/, I Roofing Fasteners Nonstructural Metal Roofing A I NeoJeWoon V 6 r i ,op 5-2 1J. Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 A, I Category Subcategory Manufacturer Product Description Florida Approval # include decimal) 5. Shutters Accordion Bahama Colonial Roll up Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name t X)40 &-I Please Print) June 2014 Z e 1 F- a s t r or 5200 W. CENTURY BLVD. LOS ANGELES, CA 90045 ONELITE SERIES FLUSH GLAZED FIBERGLASS DOOR INSWING / OUTSWING NON-impAcr GENERAL NOTES I . This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring Wind bome debris protection this product Is required to be protected with an impact resistant covering that complies with Section 1609.1.2 & R301.2.1.2 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS DESCRIPTION I Typical elevation, design pressures, & general notes 2 Door panel detailsFSHEEr# 3 Horizontal cross sections 4 Vertical cross sections 5 Buck and frame anchoring - 2X buck masonry construction 6 1 Frame anchoring - I X buck masonry construction 7 1 Bill of materials, glQzinq detail & components 11,0'MAX ' OVERALL FRAME WIDTH Z 2 7 1? 0 0 0 c I , INSWING 37.50" x 98.00" 21.00" x 79.00" 47.5 47.5 GI OUTSWING 37.50" x 96.50" 21.00" x 79.00" 50.0 50.0 0'3 0Z X. t 2 Z 0 00 0 0 n Z 0 0 0 Z jEEZ '. 0C W0 dyo) 5 0 (L M M. 11 0 0 LO W a: LO 15 5M co Ck: 0 0 TE: 0211511 FL— 15215.6 SHEEr I OF 7 A rAA) -3 INTERIOR Gl n Z 0 0 0 noz UC4-: o x 001J. Zg'- E. 0c J. c w 0 0& tn" n a:. EXTERIOR 47 m 0. T o lz HORIZONTAL CROSS SEC77ON C14 4135.75'MAX. DOOR V) PANEL WIDTH C3 zs 21.0(Y'MAX. D.L.O. WIDTH 0.69" to d fxCL- A) J m o0 0 INTERIOR EXTERIOR 0 Xll I HIM GEOIE P"C > M0 tE Callzmc in 0 - 3.59" M ud z Q ILI T q b. GIx039 U) 0 0 0 V) TCH, F777777-71— i 2 ZLaDATE: 02115112 To 0 SCAM N.T.S. 13 C4 UL Mr. BY: JK LFS 2-' VERTICAL CROSS SEC17ON DRAWNG NO.: FL- 15215.6 SHEET --L d jK I MIN. EMB. (TYP-) ic . 21 20 C tv Z Z* I vill. 0; 5 U) Z 0 Ca 0 9 z C4 . 0 N a OX z aj U 0 a. INTERIOR 40 Ul D ci CZ0 0 2 C) 17 3 3 EXTERIOR 27 G Cn, En 3 C C A E r3 HORIZONTAL CROSS SECTION V) U 525 Shown w/l X sub -buck 0 0 EMB. (TYP.) p EMB. (TYP.) mt40.15, 3 4 0.15, CSINK CSINK L ITYP-) PP.) L 20 21 21 20 V) zC, U) 7 7 INTERIOR INTERIOR z z GATF 02115112 5z4 EXTERIOR EXTERIOR SC&E: N. T. S. 9 OWG. BY.. JK CHK FrY: LFS E l HORIZONTAL CROSS SEC17ON 2 HORIZONTAL CROSS SECTION DRAMNC NO.: s'hown - inswing Outswingroshown - inswing E FL— 15215.6Vng0 pp'. ed also app ved smEET 3 OF _L AN r E csz c Z9 6; VW.. a * Z 4 r ED Z 000 0 n 4 if 51 .. z B z 4 x 0.< 2. z Old E m M.W C6 8, 5 O(L m & 9! A C Z It ji LLg 0z E VO ta. 20 7 7 0o c tn EXTERIOR INTERIOR EXTERIOR INTERIOR n M VER17CAL CROSS SECTION r2 VERTICAL CROSS SECTION co 0 Ou=g shown - inswing als ro ve Shown wl I X subbuck 0 0 0W W EXTERIOR INTERIOR m EXTERIOR INTERIOR 40 93 ILI cnz 34 7 uj z 31 z 33 F Ro Ral 1:2 12 7 E 0 z z a DATE: 02/15/12 SME: 0 N.T.S. on. BY.. JK m 3-) VERTICAL CROSS SECTION VER71CAL CROSS SEC71ON CHK BY: LFS 3: outsvAng configurafion InsvAng configurafion FL— 15215.6 SHM _L OF 43' 4 00. 4:az s 0 a a w o 7 TYP. HEAD TYP. HEAD & ' t 1) z k Y JAMBS xMASONR & JAMBS MASONRY7 z ozJ OPENING OPENING Go. o 0. or, 5 C:! x LoCOILa, LL loo c Li o 21 a: Iq FRAME on XLn Q Uzz 2X BUCK-\ v) o- 4 2XBUCK 'juo F TYP. @ SILL v) 0 v) CONCRIFTE ANCHOR NOTES: BUCK ANCHORING HINGE JAMB FRAME ANCHORING STRIKE JAMB lo 1. Concrete anchor locations at the corners may be adjusted to maintain the min. Masonry 2X buck construction edge distance to mortarloints. Q- o- 2. Concrete anchor locations noted as 'MAX. ON CENTEW'must be adjusted to maintain the rrdn. edge distance to mortarloints, additional concrete anchors 9 not exceeded. Lumayberequiredtoensurethe "MAX. ON CENTER' dimension are z 3. Concrete anchor table: IN..CLEARANCE -Q- z Aktkdk:: :ANCHOR: D TOADJACEN7 EMBE M O.MASONRY z lubENTI , ".. - - I -. TYPE: ".-SIZ A Kv:.EDGE- NCHOR OATE: 02/15/12 ITW SCALE N.T.S. TAPCONe 1/4- 1-1/4- 2" M 27 JK T 'Co 1. CHK BY. LFS ACON', TPAWW -NO WOOD SCREW INSTALLATION NOTES FL- 15215.6 1. Maintain a minimum 516'edge distance, I"end distance, & I"o.c. spacing of HINGE DETAIL LATCH & DEADBOLT DETAIL wood screws to prevent the splitting of wood. IsHEET 5 OF 7 z HINGE DETAIL LATCH & DEADBOLT DETAIL CONCRETE ANCHOR NOTES: I . Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarloints. 2. Concrete anchor locations noted as "MAX. ON CENTER"must be adjusted to maintain the min. edge distance to mortarjoints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: ANCH . 0 1 R:.: A NI CkOk IW C..CPARANCE: EM BEDME. EDGF...! ITW TAPCON* 1/4" 1-1/4" 2" 4" ITIN PCON' 3/16" 1 3" 1 I-11r WOOD SCREW IN5TALLAIION NUU:5; 1. Maintain a minimum 51*9'edge distance, I " end distance, & I " o.c. spacing of wood screws to prevent the splitting of wood. HINGEJAMB MASONRY OPENING FRAM IX BUC to d r- C; A 11 n=1 X. 6 V) W. z IIIIJI N Z o 0 0 nit, z E X 0, z') zo tL 0. 5 6 0 (LfT I' dCZ M a: cc Co 0P= 000 XUD 0 C, XU>- Ei W V3 0 FRAME ANCHORING STRIKE JAMB Masonry I X buck construction Dec. 02/15/12 SCALE: N. T. S. DWG. BY. JK CHK. BY: LFS EiiZWiNG NO.: FL— 15215.6 SHEET OF BILL OF MATERIALS ITEM DESCRiPnON MATERIAL A I X BUCK SG — 0.55 WOOD B 2X BUCK SG >= 0.55 WOOD C 114'MAX. SHIM SPACE D IXX 2-3/4'PFH ELCO OR fTW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE F 1/4'X 2-3/4'PFH ITW CONCRETE SCREW STEEL G 3116'X 3-1/4'PFH ITW CONCRETE SCREW STEEL_ H 3116'x 3-1/4!'PFH ITW CONCRETE SCREW STEEL 1 1/4" X 2-1X PFH ITW CONCRETE SCREW STEEL J 1/4"X 3-3/4"PFH ITW CONCRETE SCREW STEEL K 9 X 2-1/7'PFH WOOD SCREW STEEL L lOX2-]/Z'PFH WOOD SCREW (1.lS' MIN. EMBEDMENT) STEEL M 9 X 2-1/4!'PFH WOOD SCREW STEEL 7 Q-LON 650 WEATHERSTRIP SCHLEGEL FOAM 9 N'X 47BUTT HINGE STEEL 11 9 X 3/4" PFH WOOD SCREW STEEL 17 KWIKSET KEYED ENTRY - SIGNATURE SERIES STEEL 18 KWIKSET DEADBOLT - SIGNATURE SERIES (780) STEEL FINGER JOINTED PINE FRAME, HEAD & HINGE JAMBS WOOD 21 POLYFIBER JAMB COMP, / VINYL 27 LATCH STRIKE PLATE STEELd202BDEADBOLTSTRIKEPLATESTEEL 30 WEATHER -STOP 3647 HOLM INDUSTRIES VINYL 3 1I OUTSWING BUMP THRESHOLD ALUM. WOOD 33 INSWING ADJUSTABLE THRESHOLD BY ENDURA AWM. WOOD 34 INSWING ADJUSTABLE ALUMINUM THRESHOLD BY DUP ALUM. WOOD 38 GLAZING SPACER ALUM. 39 GLAZING BEAD PVC 40 DOOR PANEL - SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 41 DOOR SKIN (MIN. 0.095- THICK) FIBERGLASS 42 TOP RAIL CELLULAR PVC 43 LATCH & HINGE STILE CELLULAR PVC 44 LATCH & HINGE S11LE SUPPORT WOOD 45 BOTTOM RAIL CELLULAR PVC FOAM POLYURETHANE rPOLYURETHANE47STILEREINFORCEMENT STEEL 48 REINFORCEMENT RETAINING SCREW NYLON 49 GLAZING COMPOUND DOW 995 SILICONE 4.W HIAD & 51D ED Jam20Jamb 5.63" 4.68"- 5"GLASS BITE 4pN* A, rj) 3 z X-- 44 1 k z 3 N fE z0 0 0 M R If LZ E oz 3 M 4.56* --------- cu! 1 3,0. (X 4.56" cl! 2.44- EI-HIAD a SIDEDA' 21 Polyfib,,jamb 5/9'NOM. GLASS THK. I /&'TEMPERED GLASS AIR SPACE 1/8" TEMPERED GLASS u2: 0 V oQ- Lo ZE a. co o LL o t, LE: N.T.S. 3. BY: JK C BY.. LFS MING NO, u FL— 15215.6 ' c 7 oF 7 plastpro 5200 W. CENTURY BLVD. LOS ANGELES, CA 90045 Smooth / Wood Grain / White Wood Grain Rustic / Mahogany Series N Fiberglass Door INSWING / OUTSWING NON-immcr GENERAL NOTES 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code FBC) structural requirements including the "High Velocity Hurdcane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHT'this product Is required to be protected with an impact resistant covering that complies with Section 1626 of the FBC. 4. When used in areas outside of the "HVHZ" requiring wind bome debris protection, this product is required to be protected with an impact resistant covering that complies with FBC Sections 1609.1.2 & R301.2.1.2. 5. For 2x stud construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of this drowing require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations meet water infiltration requirements for"HVHT'. 8. Inswing configurations do not meet the water infiltration requirements for the "HVHT'. Inswing units shall be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. TABLE OF CONTENTS SHEEM DESCRI ON I Typical elevations, design pressures & general notes 2 Door panel details and glazing detail 3 Horizontal & Vertical Cross Sections (2X Buck) 4 Horizontal & Vertical Cross Sections (I X Buck) 5 Horizontal & Vertical Cross Sections (Direct to Masonry) 6 Vertical Cross Sections (Thresholds) 7 Horizontal & Vertical Cross Sections (Direct to Masonry) 8 Buck and frame anchoring 9 Bill of materials & components 17,51" MAX ' 0V11A11 FRAME WIDTH z 0 0M x e C! 0 PV ALL, SDESIGKPR RFSSU_ E ERAME-. WEGATI VE INSWING 37.50" x 98.00" 47.0 47.0 OUTSWING 37.50" x 96.50" 47.0 47.0 0Z V 2 ow 0 a n z 0 E 0 0 Z L) C X 3 6 0 IL 1. 0 I Oz P C) Of U0 A C) Es CD nu CL mn 0 0 =1 Of DATE: 02120112 SCALE: N. T. S. DWG. BY. J K CHK. BY: LFS DRAWNG NO, FL — 152 2 0. 11 SHEET I OF 9 13w, 81' LOCK BLOCK (2(Y' X 1.385') LATCH STILE REINFORCEMENT A H STILE (CELWLAR PVC) 35.75'MAX, DOOR PANEL WIDTH 21 MAX D.L.O. WIDTH 4!' d a3 cdz d 0 ci0 r2 Q Z z DOOR PANEL DOOR SKIN TOP RAIL MIN. 0.069" THICK) (CELLULAR PVC) INTERIOR EXTERIOR r2' HORIZONTAL CROSS SEC17ON 1\ 2 X 1 -1 /7'PFH SCREW I 7/167 GLASS BITE 1/7 OVERALL GLASS THK. I /T TEMPERED GLASS AIR SPACE 1/8" TEMPERED GLASS ALUM SPACER PF-I200P/MERJC FOAM g_g G DETAILOGLAZINODETAIL G1 ODLUTEIRAME LOCK: SIGNATURE SERIES KWIKSET DEADBOLP SIGNATURE SERIES (780) LOCK' YH COLLECTION YALE DEADIBOLT. YH COLLECTION (80 SERIES) 1.27" EXTERIOR POLYURETHANE FOAM 6 om0 jA, oil I Z 000 N Z z 0-J A E 6 co iL IL E o A -d INTERIOR 0 a AM N.T.S. Q BY.. JK K ffn LFS AWNG NO.: FL-15220.11 EET OF I-Ij EMi W6u-ts-,-m--n-g -S-h-o-w-n -(1 n--s-vA-n-g -si-m-ilar)-- - TC)Utsvmg shown linswing imlia—rT— 14* MIN. B. (TYP.) EXTERIOR INTERIOR r3' VERTICAL CROSS SEC77ON Outswing shown (Inswing similar) NISA, z Z, 0i 1) 9) 0 co 00z0N" --. z E 0 . 0 9 -0 z. N fu 6 '0 IwLU) CZ0 LJ A jxd UL Z 2 6 zo ro C,3 rF-- 02 2 U- NW G. BY.. JK kWWG NO.: FL-15220.11 EU _2L OF._a_ A. n z 0 d y.. io z 0 .0 6 0 V).. z 0 N . 0 xzo Z 0 EM M 0 X CW 0 0 a. 6 0 0z 7 A C Li E E C 2 1 C 00rv q uo ZC3 C M.- O E A- 7 7 0 v 40 e G v INTERIOR A C z L T EE 0 40 z 00 V) EXTERIOR 7 1 2 z0 W 27 G A 2 1 1/4!'MIN. 9 40 EVERIOR INTERIOR p EMB. (TYP.) M1-1 IN. EM P.) z:fl HORIZONTAL CROSS SECTION r2-" HORIZONTAL CROSS SEC17ON 3 VERTICAL CROSS SECTION Shown wl I X sub -buck Shown w/ 1 X sub -buck Shown w/ I X sub -buck z OvtswIng shown (Inswing similar) Ovtswing shown (Inswing similar) Outswing shown (Ins%4ng similar) z0 DATF- 02/20/12 z z samt N.T.S. S MO. SY.. JK M CHK. W. LFS DRAMMG . ' 10 FL— 15220.11 U1 c4 Mr 4v 9 10 Z' 4 z z 2 1% O'n z .3 o 0 z mo w A 5 d o (L a. N t.t m a: o oz c Lj E E En,)L, 2 1 C C ID D D D z C, 7 M 7 40 E C, P rr 08 MoINTERIOR m C EXTERIOR 7 z 9 L/) I I 9 EXTERIOR INTERIOR i-r j EMB. (TYP.) EMB. (TYP.) 1 HORIZONTAL CROSS SECTION 2-' HORIZONTAL CROSS SECT70N 3 VERTICAL CROSS SEC17ON Shown Direct to Masonry Shown Direct to Ma onry Shown Direct to Masonry Outswing shown finswing similar) Outs\pAng shown (Inswing similar) Outswing shown (InsvAng similar) DATE 02120112 XAM N.T.S. DWG. ffY-. JK cHK BY.. LFS DMWWG NO.: FL-15220.11 E U5 OF__L 1 .0 z Oo 0 V) oca 0ZOZ I Cn4Itax 0 z Szo E 6 'o a. 13, Z. 0v I'D: EXTERIOR I/ INTERIOR ct 1zc EXTERIOR INTERIOR C) V) 8 Ln" co Q3034Q Lp, 0 E 37 0 MH E 4 1 4 4 V) z VERTICAL CROSS SECTION rl-'\ VERTICAL CROSS SECTION lnsvAng configurafion R Pa OutsMng confkguraflon u z 0 12 scALE: N.T.S. OING. BY: JK m CHK. BY.- LFS DRAWING NO.. FL— 15220.11 SHEET OF gI t4 IhgI : z t,6 f I 1.25" MIN. EXTERIOR W INTERIOR ri" VERIICAL CROSS SECTION Shown Direct to MasonryOutswingonlywl4-9/16'jamb INTERIOR 1-1/4"MIN. cli EMB. (TYP.) B(TERIOR ED EMB. (TYP.) HORIZONTAL CROSS SECTION 2' HORIZONTAL CROSS SECTION 7 \, 7 Shown Direct to MosonrShownDirecttoMasonry yOutswingonlyw/ 4-9/16'iamb Outswing only w/ 4-9/16'jamb C Er) Z N EXTERIOR INTERIOR r6 " VERTICAL CROSS SECTION 7 Shown Direct to Masolnry OutswIng only w/ 6-9/ , jamb 1-1/4' MIN. EMB. (TYP.) 3 HORIZONTAL CROSS SECTION Shown Direct to Masonry Outswing only w/ 6-9/16'jamb INTERIO EXTERIO MAX. I.S, MAX. 41F O z— Es 3,q 10 Z 0 OD 0 0 0) z U N a x 0 z ozo E 6 0 m V),t m a: a, 1z E co z I L no at 0 OR E3 Cf) it i rq SULL N.T.S. r4- HORIZONTAL CROSS SECTION JK 7 Shown Direct to Masonry CHK. BY: LFS Outswing only w/ 6-9116'jamb FRAMNG No.: FL-15220.11 sHEEr oF 9 TYP. HEADMASONRY7 - & JAMBS OPENING c6 2X BUCKANCHORING CONCRErE ANCHOR NOTES: 1. Concrete anchor locations at the comets may be adjusted to maintain the min. edge distance to mortarjoints. 2. Concrete anchorlocations noted as"MAX. ON CENTER"must be adjusted to maintain the min. edge distance to mortarloints, additional conomfe anction, may be required to ensure the IMAX ON CENTER'dimension are not exceeded. 3. Concrete anchor table: MOOR, ANCH6 MIN. AIN CLEARA 15 MlN;,.CLEARANC E TYPE: TQMASQNRW-11 ADJACENT., EDGE_ ANCHOR ITW TAPCONS 7ELCO 114' 1-114' 4" ULTRACOk' lrw 3/16- 1-1/'r 3' TAPCONe wviJu 3LKt:yy JMLALLAIIU[4 NVIn: 1. Maintain a Minimum 518"edge distance, l"end distance, & l"o.c. spacing ofIwoodscrewstopreventthesplittingofwood. STPJKEJAMB DIRECT TO MASONRY I X BUCK 2XBUCK DIRECT TO MASONRY JAMB (TYP.) 4-9/16"JAMB (SEE SHEET 7) 2X BUCK G 1 X BUCK DIRECT TO MASONRY MASONRY OPENING TYP. HEAD JAMBS FRAME 46-9/16'JAMB 4-9116' JAMB M MB N to DIRECT TO j MASONRY JAMB (TYP.) 2XBUCK SEE SHEET 7) H OUTSWINGAAINSWING TYP. @ SILL t FRAME ANCHORING I * I HINGE DETAIL J L) n KEY 0: W 6 z 0,0 6 0 n z U 4 .: a X ZO z N E O 6 OIL G a- E '0 Z 0Z U0 Lu no Goas in J 0 0 0 00, CL FFFM T' HINGE JAMB LATCH & DEADBOLT DETAIL DIRECTTO MASONRY I X BUCK 2X BUCK DIRECT TO MASONRY I X BUCK 2X BUCK z DATE: 02120112 SCALE: T.S. DING. BY-. JK CHK BY. LFS DRAWING No: FL— 15220.11 SHEET OF 9 BILL OF MATERIALS IrEM # DESCRIPWN MATERIAL A IX BUCK SG >= 0.55 WOOD B 2X BUCK SG >= 0.55 WOOD C 114'MAX. SHIM SPACE D 1/4!'X 2-3/4'PFH ELCO OR ITWtONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE G 3/16'x3-1/,V'PFH ITW CONCRETE SCREW STEEL H IXX 3-1/4!'PFH ELCO OR ITW CONCRETE SCREW STEEL I 1/47'X 1-3/4'PFH ELCO OR ITW CONCRETE SCREW STEEL J 1/4!.X 3-3/4'PFH ELCO OR ITW CONCRETE SCREW STEEL K 1/4!'X 2-1/4'ITW CONCRETE SCREW STEEL L 10 X 2-1 /Z'PFH WOOD SCREW (1.15" MIN. EMBEDMENT) STEEL M 3/16" X 2-1/47ITW CONCRETE SCREW STEEL N 3/1 6'X 2-3/4'ITW CONCRETE SCREW STEEL P 114'X 2-1/4'PFH ELCO CONCRETE SCREW STEEL 1 POLY FIBER JAMB COMP. / VINYL 2 FINGER JOINTED PINE FRAME WOOD 7 WEATHERSTRIP FOAM 8_ DOOR BOTTOM SWEEP VINYL 9 4'X 4'BUTT HINGE STEEL 11 9 X 3/4" PFH WOOD SCREW STEEL 27 LATCH STRIKE PLATE STEEL 28 DEADBOLT STRIKE PLATE STEEL 30 OUTSWING THRESHOLD ALUM/WO 34 OUTSWING THRESHOLD ALUM/WOOD 37 INSWING THRESHOLD ALUMIWOOD 40 DOOR PANEL - SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 58 8 X 7'PFH WOOD SCREW STEEL I THRESHOLD 37 D IISCS) 4.56' 2.44 2.13"- POLY FIBER JAMB p- -- , , , -- - 4.56" 2.36' WOOD JAMB ll ci Li 0.57, W- WEATHERSTRIP urc F—e 5 3 2— WING THRESHOLD0DLT(QoSj vl d) V. c .90 M ell ID U) Zo o Q N 11 x 0Z0Z SM 0. CL E c z Ld 2.088" DOOR 8070M SWEEP M2 WIN 'HRESHOLD lb—nlij-h Dam (581) 0 C:, 0 DATE- 02120112 SCALE, N.T.S. c DWG. BY: CHIC BY: LFS 3 FRAVOWC NO a FL- 15220 11 SHEET 9 OF 9 S plastpro 5200 W. CENTURY BLVD. LOS ANGELES, CA 90045 ONELITE SERIES FLUSH GLAZED FIBERGLASS DOOR INSWING / OUTSWING WON-tmmcr GENERAL NOTES I . This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debds protection this product is required to be protected with an impact resistant covering that complies with Section 1609.1.2 & R301.2.1.2 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction, 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS SHEET # DESCRIPTION I Typical elevation, design pressures, & general notes 2 Door panel details 3 Hoi—ntal cross sections 4 Vertical cross sections 5 Buck and frame anchoring - 2X buck masonry constructibn 6 Frame anchoring - I X buck masonry construction 7 Bill of motedols, glazing detail & components 37.5(Y'MAX. OVERALL 11AM1 WIDTH T 0 (D z z ED 0 > 0 6 E RALL y . d 'EQV kALI: ESIO SWING.__ F L 0 Dl S1 IMENSION_.." TYPE- SMVE NEGAUVE INSWING 37.50" x 82.09' 26.25" x 65.9S' 50.0 50.0 G 1 OUTSWING 37.50" x 80.50" 26.25" x 65.9X' 50.0 50.0 3 V) z 7e 6, 1/1, Pf Z, C;;.5 0 n z z b 0 Z. 3 C, W CM 5 0,0_ 0 8, 0 i0z Lj A >,.: 3 1 P d 0 MT Z DATE: 02115112 1z SCALE: N. T. S. DWG. BY: J K CHX. BY: LFS ORAWING NO.. FL-15215.1 C SHEET _L OF Q7 ci 75 r! u z 15 w 44 46 IN TERIOR 39 C;; 4-2)- R 0; n tole n, Z* 0 04 0 xz0 C3rlzE u oa. EXTERIOR Q6 m 10 m 0. Im ZOE0 l HORIZONTAL CROSS SECTION 3'd 2 0: 1.22' cn 35.75'MAX. 1.59" DOOR F7777771 u :1 cl: PANEL WIDTH Ot: DO21.25'MAX. INTERIOR EVERIOR D.L.O. WIDTH 0r2 0 42 TOP RAIL AMH I HINGE STILE PTellularPVCC m10w-,Pllc 39 T E C5 0 x 28 0 0 K REIN IQRCEMENUOC Wod t" 1c, z 1.59" T : 7 : F7777771 z 2 DATE: 02115172La scALE; N.T.S. QM ICAII TCH HINGE 2 VER17CAL CROSS SECnON DWG. BY.. JK C Julo," l I w.,>de CHK, BY: LFS DRAWING NO.. FL- 75215.1 SHEEr _,L W 7 1 -1 /,VMIN. ............. EMB. (TYP.) 21 20 (C SAFA, z z 00, Inz 0 W d 0 V) z 0 C4 0 x 7 Go CSINTERIOR T23 p C Z') 3 t: '0 3 2: Of 60 LO EXTERIOR V) E 3—" HORIZONTAL CROSS SECTION CL m Shown w/I X sub -buck rz < N 1 -1 /If, MIN. 0 i x EMB. (TYP.) W i EMB. (rYP.) Co 0.1s, 0.16, CSINK CSINK L (TYP-) Ryp.) L 20 21 V) a La 77 0 INTERIOR INTERIOR EXTERIOR EXTERIOR DATE: E115112V4 ( SCALF-- N.T.S. 27 By! JK FS HORIZONTAL CROSS SEC77ON H CTION E IG No' Ogt mng shown - insMng \'!O..t. shown - insvAng L_ pro g F 1'215.1 a ap ved moved L SHFET 3 OF 7 z A-0 n E z D E 4 till z o d 0 ') Zti% 0 C11 z 0 x 0 z OZOEM , C W 6 0 (L a: a, L 71 A F4 CO E Co Z 7 9 i R Q 40 40 20 LO 7 7 21 EXTERIOR INTERIOR EXTERIOR INTERIOR 0 to L1Lna rf'\ VER77CAL CROSS SECTION I/ 2 VERTICAL CROSS SECTION Ovtswing shown - Inswing also approved Shown w/1 X sub -buck 0 EXTERIOR INTERIOR EXTERIOR INTERIOR U) z 11 20 7 34 ju 31 33 z E 0z DATF- 02115112 SCAM N.T.S. DWO. BY: JK ri- VER17CAL CROSS SECTION VERTICAL CROSS SECTION CHK. BY. LFS DRAWINC NO... Outswing configuration Inswing configuration FL— 15215.1 sH EEr 4 OF 7 MASONRY OPENING 2X BUC o cL: 0. 0 BUCKANCHORING STRIKE JAMS CONCRETE ANCHOR NOTES: I . Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. 2 . Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortorjoints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension ore not exceeded. 3. Concrete anchor table: MIM C.LE 9 NCE MINJC[EARANCE: EDNIENT. TO MASONRY:..::: TO:ADJACENT-.. TYPE.::. E,::-: ANCHOR: ITW 1/4- 1-1/4" 2" 4" TAPCONO ELCO 1/4" 1-1/4- 1. 4" ULTRACON WOOD SCREW INSTALLATION NOTES: 1. Maintain a minimum 518" edge distance, I " end distance, & I " o.c. spacing of wood screm to prevent the splitting of wood. MASONRY OPENING FRAME 2X BUCK 21 to Eq U d 1 FRAME ANCHORING Masonry 2X buck construction LATCH & DEADSOLT DETAIL z p== v A C;Z 6 C w 6 c; G3 : 0. CE - V 0Sd. N2: a LO 0 0 M03 HINGE JAMB HINGE DETAIL DATE: 02/15/12 SCALE: N.T.S. DING. BY: JK CHK BY: LFS DRAWING NO.: FL-15215.1 SHEET OF _L fZ® R., c 0 z 9 J 8 n z TYP. HEAD & E M MASONRY JAMBS w 0. d. W OPENiNG 0 z La E0 11: e HINGE DETAIL FRAME MC) Li 0 ><u 10 :3 0 1 V) Z(OiRz00ZUIXBUCK0 > LU r 0 p Ct 03 z STRIKE JAMB FPAME ANCHORING HINGE JAMB LATCH DEADBOLT DETAIL 0 Masonry 1 X buck construction CONCRETE ANCHOR NOTES: 1. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortarloints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: ANCHOV :A14CH01Z. . W-IN: MIN_:i:LfARANCE: :MIN -CLEARANCE ToAMONW: 46 AWAwWEMREDIVEW t ITW 02115112 TAPCON 1/4- 1-1/4- 2- Ir scAu: N.T.S. ITW OWG. BY: JK i I T PCONO 3/16" 3" CHK BY. LFS 3 WOOD SCREW INSTA"TION NOTES: DRAWING No: 1. Maintain a minimum 518" edge distance, I " end distance, & I o.c. spacing of FL- 15215.1 wood screws to prevent the splitting of wood. SHEE'r 6 OF 7 BILL OF MATERIALS G, ITEM DESCRIPTION MATERIAL 4.56'- A I X BUCK SIG — 0.55 WOOD Fit 8 WOODB2XBUCKSG — 0.55 3. :z- to*. 6 : pC1/4'MAX. SHIM SPACE Z CcD1/4!'X 2-3/4'PFH ELCO OR ITW CONCRETE SCREW STEEL EM= 1 1--- E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI CONCRETE 2.44" Z' d; 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 On z G 3/16" X 3-1/4"PFH ITW CONCRETE SCREW STEEL 0 cq HEAD & SIDE 0 -z H 3/16" x 3-1/4'PFH ITW CONCRETE SCREW STEEL 20 = I SIDE Jamb J 1/4" X 3-3/4!'PFH [TW CONCRETE SCREW STEEL CM 6 Gwu) K #9 X 2-1 /7'PFH WOOD SCREW STEEL a L #10 X 2-1/Z' PFH WOODSCREW (11.11s- MIN. EMBEDMENT) STEEL 0 5.63' 0z M #9 X 2-1/4'PFH WOOD SCREW STEEL 4.56" T Li 7 Q-LON 650 WEATHERSTRil' SCHLEGEL FOAM 9 4!'X 4'BUTT HINGE STEEL 10 NOT USED 11 #9 X 3/4'PFH WOOD SCREW STEEL Of 17 KWIKSET KEYED ENTRY - SIGNATURE SERIES STEEL 0 OL Izi v;c) 18 KWIKSET DEADBOLT - SIGNATURE SERIES (780) -11- STEEL ADJUSTABLE INSWING THRESHOLD cc :a 20 FINGER JOINTED PINE FRAME, HEAD & HINGE JAMBS WOOD Q: 21 POLYFIBER JAMB COMP. / VINYL STEEL a- Ill27LATCHSTRIKEPLATE !s as 28 DEADBOLT STRIKE PLATE STEEL r i , 4.56" 30 WEATHER -STOP 3647 HOLM INDUSTRIES VINYL 4.69' 0 C3 0 rD 31 OUTSWING BUMP THRESHOLD 0 ALUM. WOOD 0 1 33 INSWING ADJUSTABLE THRESHOLD BY ENDURA ALUM. WOOD 34 INSWING ADJUSTABLE ALUMINUM THRESHOLD BY DLP ALUM. WOOD 38 GLAZING SPACER ALUM. LE: 39 GLAZING BEAD PVC T 2.44!' 40 DOOR PANEL - SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 8 HEAD & SIDEtLIA0,111DITHICK) FIBERGLASS OUTSWING BUMP THRESHOLD Poly fiber jamb G41DOORSKIN (Ml .0.075 21 42 TOP RAIL CELLULAR PVC V) z 43 LATCH &HINGE STILE CELLULAR PVC 9U) 44 LOCK REINFORCEMENT WOOD YGLASS 518" NOM. 45 BOTTOM RAIL CELLULAR PVC BfTE GLASSTHK. 46 POLYURETHANE FOAM POLYURIETHANE 1:2 47 CONTINUOUS LATCH & HINGE STILE REINFORCEMENT WOOD 1 /8" TEMPERED 49 GLAZING COMPOUND DOW 995 SILICONE GLASS z z AIR SPACE 38 1/8" TEMPERED GLASS DATE, 02115112 49 SCAU: N.T.S. YK- DWG. BY. CHK. BY. LFS DRAWING NO.: FL- 15215.1ELIBY7OLIF7 0 SH N L OF _L 0 122 Product SpecificationsEllffil QUIK-Stick HT High -temperature (smooth poly surface) Uses & Descri[:)tion QUIK-Stick HT is an SIBS modified self -adhering membrane reinforced with non -woven fiberglass mat for extra strength and durability. It's non-abrasive polyester surface is excellent for use in tile and metal applications. For use on decks 2:112 and greater. Benefits Offers a skid resistant, polyester surface. Silicone -treated, split -back, release film allows for easy installation and han- dling Softening point is a minimum of 250OF May be installed directly to concrete, plywood, wood composition board and gypsum Self seals around nails May be used in new construction or re -roofing Offers greater tear resistance than traditional felt underlayment Provides protection for critical areas such as rakes, eaves, valleys, flashings, hips, ridges, dormers and skylights Provides excellent low temperature flexibility May be left exposed up to 90 days prior to application of finished roof Florida Approval (FL #17401) ICC Approval (ESR-3123) Miami -Dade Approval Specifications AbTM D 1970 Thickness, min 60 mils Maximum Load, min MD=80 CD=40 Elongation at Break, min 30% Adhesion to Plywood @ 77 OF min 30.0 lbf/ft Thermal Stability, max 0.05 Flexibilily Temperature, @ -20 OF min pass Sealability around nail pass Water Proof Integrity after Low Temp. Flex pass Waterproof Integrii!y of lap Seam pass Slip Resistance pass Rolls per Pallet (label / box) 25/ 25 Roll Weight 70 lbs :h 2lbs Roll Diameter 8.5 in. Square feet. 200 Available roll dimensions 36" x 66.8'(200sqft) MID —STATES ASPHALT Tuscaloosa, AL 1 (800) 489 -2391 www.msaroof.com 4/19/2012 0 C> NOTES NOTES 1. GLAZING OPTIONS - 090' MINIMUM S 9 GLAZING IN MOLDED FRAMES SCREWED TOGETHER NTH A MINIMUM OF 10) #Sxl' ED EWS INSTALLED IN TOP OR INTERMEDIATE SECTION (NTH OR WITHOUT DECORATIVE INSERTS) MEETS UNIFORM D STATIC WHO PRESSURES SHOWN ON THIS DRAWING. GLAZING SHALL HAVE A MAXIMUM HEIGHT Of 10 69' AND A MAXIMUM LENGTH OF 16.94* . GLAZING IS N T IMPACT RESISTANT AND DOES NOT M ET THE REQUIREMENTS FOR WIND-BORNE DEBRIS REGIONS. 2 VINY- OR WOOD DOM STOP NAILED A MAXIMUM OF 6' D.C. MUST OVERLAP TOP AND BOTH ENDS OF PANELS MINIMUM 7/16" TO MEET NEGATIVE PRESSURES. 3. KEY LOCK, SUDE LOCKS, OR OPERATOR REQUIRED. 4. LOUVER OPTION - .040' MINIMUM LOUVERS IN MOLDED FRAMES SCREWED TOGETHER NTH A MINIMUM OF (10) 48.1" SCREWS IN STALLED IN THE BOTTOM SECTION LOUVERS ARE NOT IMPACT R SISTANT AND DO NOT MEET THE REQUIREMENTS FOR WND-BORNE DEBRIS REGIONS. c 5. SECPON STEEL TO HAVE A MINIMUM 26 CA THICKNESS. 6 THE DESIGN OF THE SUPPORTING SiRUCTURAL ELEMENTS SHALL BE THE RE PONSIBILITY OF THE PROFESSIO Al - OF RECUR FOR THE BUILDING OR S RUCTURE AND IN ACCORDANCE WITH CURRE T BUILDING CODES FOR THE LOADS LISTED ON THIS DRAWNG. 7. DOOR JAMS TO BE MINIMUM 2.4 STRUCTURAL GRADE LUMBER. REFER TO JAMB CONNECTION SUPPLEMENT FOR ATTACHMENT TO SUPPORTING STRUCTURE. 8 FOR LOW HEAD ROOM LIFT CONDITIONS, TOP BRACKET SHALL BE A 13 GA LHR 7/4 TOP BRACKET NTH A MINIMUM OF (3) 1/4-14.7/8" SELF DRLLING CRIMPTITE SCREWS IN UEU OF ME BRACK T SHOWN ON THIS DRAWING, U-SAR ON TO SECTION SHALL BE INSTAL ON TOP CIE LHR TOP BRACKETS, 9. IN LIEU OF THE SHORt PANEL EMBOSSMENT SHOWN. LONG PANEL EM80SSMEN T. V12 PANEL EMBOSSMENT, OR NO EM80SSMENT MAY BE USED. A I 7 6 FAI' TRACK TYPE SHOWN BELOW 13 CA HORIZ ANGLE 1.3 CA FLAG ANGLE 16 CA MIN HORHTRACK LAG SCREW (MIN 3 -1 AS SHOWN) 4) 1/4-20 9/16" LARGE HEAD TRACK DOLTS OR 1/4-20 STUDS NTH 1/4-20 HEX NUTS 16 GA MIN VERTTRACK 1 /4-20.9/16- TRACK E30LT AND 1/4-20 HEX NUT AT EACH JG-US JAMS BRACKET LOCATION 5/16.1-5/8" LAG SCREW AT EACH JAMS BRACKET 15 GA STIFFENED JAMS BRACKETS SEE SCHELDULE FOR QUANFTY, LOCATION, AND TYPE KEY LOCK OR SLIDE LOCK EACH END (NOT REQUIRED WITH OPERATOR - SEE NOTE 3). SLIDE LOCK SHOWN FOR CLARITY NCTEi (4) SECTION SOLID DOOR SHOWN SEE SHEET 2 FOR U-BAR LOCATIONS ON DOORS WITH OTHER SE TION QUANTITIES AND SEE NOTE 1 THIS SHEET FOR GLAZING OPTIONS. 14 GA MIN HEADPLATEPL T' 16 GA HORIZONTALrTRACK LAGSCREW 15 GA MIN AT EACH TRANSITION ELLIPSE JAMSBRACKET 11 CA MIN VERT TRACK 12 GA JAMB BRACKETS SEE SCHEDULE FOR QUANTITY. LOCATION AND NCR" TYPE TRACK TYPE SUPERIMPOSED DESIGN PRESSURE LOADS ON SUPPORTING STRUCTURE D',' 1 H'EoiG`H`T UNIFORM LOAD EACH JAMB (PILE) 10-01 A 462.0/-69.0io; 1 74.4/-82.8 0- ALL 1 86.8/-96.6 22 /_ " 11 Ll., 16' ::. 2R ALL I . .22T- 4 2 1 - I REViSIETNS STATIC PRESSURE RATINGS I APPROVED SIZES WTI:IET 11. i: WDESIGNPRESSURE(PSF): 12.4/-13-8 1IMAX 210JIMPACT/CYCLIC RATED! NO IMAX SECTION HEIGHT! olk,11111", JAMB BRACKET SCHEDULE DOORHEIGHT M, OFSECT'ONS N "M' BRACKETS EACH JAMS) TRACKTYPE LOCATION OF CENTEREINE OF JAMB BRACKETS MEASURED FROOFTRACK (ALL DlMENSlONMSB±oT2Fo)M 6'-6" 4 4 FAT LO- (JB-US). 25-3/4- (JB-US). 39- (JS-US). 57-1/4" (JB-US) NCR 5" (STD). 22-1/2" (STD), 35-3/4- (STD), 67" (STD) 7'-0' 4 FAT 10- (JB-US). 29-3/4' (JB-US). 42- (JB-US). 63-1/4- (JEF-US) NGR TO . 17'_' n(j4N 7'-6- 5 5 FAT WGR UU22.-1 2 37 T S). (J._ US), 7+-1/2" (JB-US)__ 5" (STD), 22-1/2" (STE). 35-L/1' . 'S ID' (STD) 8'-0' 5 5 FAT U61WD10- (JB-US), 29-3/4" (JB-US S) MlL 2- (JB-US). 77-1/2" (JB-US) NOR 1 1) 1-leW " (ITD), 31-3/' (ITD), 137" (ETD), 80- (STD) 2 N_. T ... A) I FLOW I D I c I B NOTE 0 FAT AND NGR) FOLL WNG DIMENSION DENOTES SLOTTED JAMB BRACKET ATTACHED TO TRACK WTH 1/4-20.9/16" TRACK BOLT AND NUT. DWAY E Ibi I IN K RNISH, PE ALL DOORS GREATER THAN EV IN HEIGHT REQUIRE USE OF CONTINUOUS WALL ANGLE SEE SUPPLEMENT TRACK CHART FOR DETAILS. 4576 COUNTY ROAD 160 MOUNT HOPE. OHIO FL PE 77945 SERIES 170-177, 180-187 TX RE 117868 ENGI SPROFESSIONALINEER'S EAL PROVIDED ONLY FO I VERIFICATION OF WIND LOAD CONSTRUCTION DETALS. THE DRAWINGS AN ALL OTHER INFORMATION CONTAMED HMON ME THE CONFIDENTIAL AND PROPRIETARY PROPSTTY OF OVERHEAD DOOR CORPORATION AND ITS AFIRUATED COMPANIES, THIS D Wl G AND INFORMATION, IN -0LE OR IN PART, MAY NOT BE COPIED IN ANY MANMER OR DISCLOSED TO M-HE MHOUT THE PROR AHY OF THIS DRAWING OR -R"TON IS HITENGED TO OPERATE AS A LICENSE OR AUTHORGATION TO IT FOR ANY PURPOSEWRITTEN CONSENT OF OVDRHEAD DOOR CGRPMTION. NO DISCLOSURE OFOGTTHESPOCnCWNITTEINCGHRENTOFG&RHEAD DOOR CORPOIRATION, HQUE DIAMETER WHOLE FINISH N/A I I S 18OWLFRIES170, 11H .211 OlI- _ I DO, IG NJ EIE- G. TAYLOR MAX WIDE DD R SOO 0 3 UNIT OFMEASURE M!`EAVVICKI lo/ 41 REF END Us ED ON E691IONS1/16 X DID ANGLES: EACH NUNL 47TJ;NGF 0= 01 10 T,5, 111 0' NTI 1 4 1 3___F_ 2 1 v 8 1 NOTES REVI IONS 16 CA RO ER SUDE ATTACHED TO W5851 NfU-E_PE7E!R BRACKET WITH 1/4-2D.5/8 BOLT & 307041 P R " I 111'Z'2 I RTNUTINCENTERSLOTCENTERSTILEDQN581RAT— BLDOK 11.1 12.111 QO 16' 16 GA UNIOR 'A' FRAME TOP U-13AR LOCATIONS BRACKET ATTACHED NTH (4) SELF DRILLING 132) S GION ... 13 WITHmm'mr] -BARS GR"P TIq SCREWS— 10) 3 0 CA 80 KSI U LOCATED AS SHOWN DETAIL 14' & 1' S7) ECTION DOORS VATH 20 LOG9) 3 CA 80 KSI U-BARS TED AS SHOWN2NYLONSILENTGLIDE ROLLER WITH 4" STEM S CTION DOORS WTH 19 G NARROW BODY (8) 3 20 GA 80 KSI U-BARS END HINGE ATTACHED OCATED AS SHOWN NTH (4) 1/4-14.5/8" SELF TAPPING SCREW GETAH B 10, S) SECTION DOORS WITH 7) 3 20 GA 80 KSI U-SARS LOCATED AS SHOWN D D 18 CA NARROW BODY D IJE INTERMEDIA GETEHING ATT CHED NTH (4) D 1/4-14x5/8.' SELF TAPPING SCREWS 4) S CTION DO RS NTH D 5) 3 20 CA 80 KSI U-BARS 14 CA BOTTOM BRACKET LOCATED AS SHOWN D D ATTACHED NTH (2) 1/4- 1 4.7/8" SELF DRILLING D D CRIMPT' TE SCREWS AND 0) 1/4-1 41/8" SELF DRILLING a D D TAMPER RESISTANT SCREW 1.) D D D D I D D D D D D D NO.77945 D ATTACH U-BAR NTH D D R2) 1/4-140/R" SELF MET EDRILLINGCRIMPTITE D D S SSCREWSOATEACH STATE TILE L CATION, TYP. D fLOR\... D D DWAYNE KORNISH. PE 4576 COUNTY ROA.) 160 MOUNT HOPE, 0 10FLPE77945H TX PE 1 17868 PROFESSIONAL ENGINEER'S SEk PROVIDED ONLY FOR VERIFICATION OF WIND LOAD CONSTRUCTION DETAILS. TK DRAW GS AND &L OMER INFORMTION CONTAINED HEREIN ME THE OONRDENMAL AND PROPRIETARY PROPERTY OF OVERHEAD DOOR CORPORATION AND ITS AFHUATED COMPARIES. THIS DRAM G AND INFIRPATION. IN WHOLE OR IN PARL AA' NOT BE COPIED IN ANY —HER OR DISCLOSED TO ANYONE WHOM THE PRIOR WFTEN CONSENT OF 011RHEAD DOOR CORPORATION. NO DISOLMI.IRE OF ANY OF THIS ORNIRWO M VMRWM IS IMENDE3 TO OPERATT M A UCENSE OR AUTHORIZATION TO IT FOR AM PURPOSE WTHOJT - SKCIFIC WRITTEN -T OF C,URREAD DOOR CORPORATION. ISH 4) WHOU' 25 _G TAYLOR 10/15/101 S , EkS - 1 1 70 " . 18OWL ERS' - N/A 1 X WIDE UNIT OF " M SLICKI 25i/10xxOIDMEASURE To/ D-41 1044G, Fie: xxx 0 EACH NONE DIJ,S. 2 2FEEDINGUSEDDNm ± F. TJ;NG 11/23/10 1 4 .3 2 1 1 a m ELEVATION 36" 27 typ. — 12. OX max. 2' typ. 12* o.c. Max. a-l-k'CLFARANCE ALL FOUR SIDES) Anchor See Section Detall.$) Min Edgel 7/16" SHEATHING Min Edge 7/16" JAMB DETAIL NAIL FIN' IS A GENERIC TERM WHICH MEANS 'MOUNTING FLANGE'. NOT TO BE CONFUSED WITH '1/2' FRONT FLANGE) HEAD DETAIL SHEATHING/OSB SIZE HEADER AS NEEDED CAULK UNDER NAILING FIN ENTIRE PERIMETER BEFORE FASTENING. 8 X 1- 5/ 8-sCREW (SHOWN ' NTH j- SHEATHING) MUST ACHIEVE 1-1/4" PENETRATION INTO STUD s SILL DETAIL Notes: 1. Installation depicted based off of structural test report #C7327.01-109-47. 2. Wood screws shall satisfy the National Design Specification foe Wood Construction for material type and dimensional requirements. 3. Wood buck, installations are assumed 2x S-0-17 (G=0.42) at denser. Buck width shall be greater than the window frame width. Tapered or partial width bucks are not allowed. Wood buck shall be secured to the structure to resist all design loads. 4. Wood screw lengths shall be sufficient to guarantee 1-1/4' penetration into wood buck. 5. Maximum 'shim. thickness of 1/4" Permitted at each fastener location. Shims shall be load bearing. noh compressible type. 6. These drawings depict the details necessary to meet structural load requirements. They., do not address the air infiltration, water penetration, intrusion or thermal performance requirements of the installatiom 7 Installation shown is that of the test wI ihdow for the size shown and the design pressure claimed. For window sizes smaller than shown, locate fasteners approx 2" from corners and no more than 12" on center. Design pressures of smaller window sizes are limited to that of the test window. SIZE AND DESIGN PRESSURE CHART FASTENER TYPE AND SPACING SHOWN ELL ALLOW DESIGN PRESSURES UP TO +35/ -50 UNITS UP TO 36" x 74" SEE TEST REPORTS FOR INDIVIDUAL UNIT SIZE AND APPLICABLE DESIGN. PRESSURE LIMITATlONS) u" INSTALLAT10N INSTRUCTIONS FASTENER SCHEDULE: FiN- PRODun mAw 7 V. M. R. CHECaD., 12-14-09 - DAID Windows & Doors 3540 Single Hung NONE M 1 1 Gratz, PA 3540 3240 SH FINTT NOTES: 1 . THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING 13 THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. IX BUCK OVER MASON RY/CONC R ETE IS OPTIONAL. T WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE.. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSiBILITY OF HE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. SHIM AS REQUIRED AT WITH LOAD BEARING SHIM. SHIM. WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4", 9, SHIMS SHALL BE MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE LOADS, LOCATED AND PPLIED IN A THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10, WIND LOAD DURATION FACTOR Cd 1.15 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04. 13. APPROVED IMPACT PROTECHVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLA71ON DETAILS, REVISIONS DESCRIPTION DATE APPROVE6 REVISED PER NEW TESTING 01/08/14 R L. REVISED INSTALLATION DETAILS 09/15/15 R,L, 15. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE: LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND NSTALT TION DETAILS. 16 FOR ANCHORING INTO METAL STRUCTURE USE #8 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS K41NIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS, 17. ALL FASTENERS TO BE CORROSION RESISTANT. 18, INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF 0=0.42 B. CONCRETE MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. C. MASONRY STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE I (OR GREATER). D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 1/8" THICK MINIMUM TABLE OF CONTENTS I EET NO: I NOTES 2 ELEVATION 3 — 5 INSTALLATION DETAILS SIGNED: 0911512015 MI WINDOWS AND DOORS lil, 650 WEST MARKET STREET 04i /-, GRATZ, PA 17030-0370 GEN q* :4 p z: 0 9:51SERIES3240/3540 FLANGE PVC SINGLE HUNG STEEL REINFORCED WINDOW NON -IMPACT 36"xd74=. NOTES TAf OF 5 0 DRAWN. DWI, NO_ EV TiH 08-01252L05/23/1 1 1 36" MAX. FRAME WIDTH 4" M AX. 4" MAX. 4" MAX T_- SEE ANCHOR CHART THIS SHEET FOR JNIT— SIZE AND ANCHOR OUANTITY 74" MAX. T-1 FRAME0/ HEIGHT 22" MAX. __ 7O.C. 33 3/8" MAX. SASH HEIGHT x 4" MAX. T_ SERIES 324013540 FLANGE PVC SINGLE HUNG WINDOW EXTERIOR VIEW DESIGN PRESSURE RATING IMPACTRATING 35.0 PSF 50. 0 PSF NONE REVISICN5 REV ESCRIPTION DATE APPROVED A REVISED PER NEW TESTING 01/08/14 r, L. B REVISED INSTALLATION DETAILS 09/15/15 R. L. I NUMBER OF ANCHOR LOCATIONS P.EQUIRED Fmm Fmm Width (in) Height 1 24.00 30.00 36.00 i n) 8 607 Hwd Jamb Head Jamb Hezd Jorrib 24 OL 2 2 2 2 2 2 2 2 30.00 2 2 2 2 2 2 2 2 36.00 2 2 2 2 2 2 2 2 1 42.00 2__ 3 2 3 2 3 2 3 48.00 2 3 2 3 2 3 2 3 54.00 2 3 2 3 2 3 60.00 2 3 i 2 3 66.00 2 3 2 3 2 3 2 4 7100 2 3 2 3 2 1 4 2 4 3 2 3 2 1 4 4 MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 3240/3540 FLANGE PVC SINGLE HUNG STEEL REINFORCED WINDOW NON —IMPACT 36"x74" ELEVATION DRAWN: DWG NO REV TJH 08-01252 B 05/23/11 1 SIEE _'2 OF 5 SIGNED: 0911512015 0NIIIIIII//11, 0 1// r, E Aty 0 TA 'OF-14LI-z-Z 0. 2'. ZORVOt. 6,*-. " .-* 0 N A L 1/2" MIN. EDGE DISTANCE WOOD FRAMING OR 2X BUCK lx BY OTHERS 1 1/4" MIN. 1 " 4l EMBEDMENT APPROVED SEALANT 1 /4 MA, HIM SPACESSHVSP 0Oj8WOOD SCREW REINIORCIMENT GVL-451-020 f;:"zRF- 104S-020 REINFORCEMENT EXTERIOR APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS cDlnm 11.1 GVL-451-020 REINFORCEMENT SILL TO BE SET IN A BED OF APPROVED CONSTRUCTION ADHESIVE 1 /4 MAX. FSHIM SPACE L F VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 REVISIONS REV DESCRIPTION APPROVED A REV15ED PER NEW TESTING 01/08/14 R L.. 13 REVISED INSTALLATION DETAILS 09/15/15 R. L. I 1 1/4" MIN EMBEDMENT 4 MAX. SHIM SPACE CVL - 451 - 020 REINFORCEMENT 1/2" MIN, INTERIOR EDGE DISTANCE 8 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS APPROVED EXTERIOR SEALANT JAMB INSTALLATION DETAIL WOOD. FRAMING OR 2X BUCK INSTALLATION MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 3240/3540 FLANGE PVC SINGLE HUNG STEEL REINFORCED WINDOW NON -IMPACT 36"x74" INSTALLATION DETAILS CRAWN REV 08-01252 B I lAlE NITS I DATE 05/23/11 SHEET 3 OF 5 SIGNED: 0911512015 V METAL STRUCTURE BY OTHERS APPROVED SEALANT EXTERIOR APPROVED SEALANT MET STRUCTUI BY 01-HEI 5/8" MIN. EDGE DISTANCE L1/ 4 MAX. F SHIM SPACE 8 SMS OR SELF DRILLING SCREW RF-104S-020 REINFORCEMENT GVL-451 -020 REINFORCEMENT colflo 11.1 151-020 DRCEMENT VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 TO BE SET BED OF APPROVED JSTRUCTION ADHESIVE 1/4 MAX. SHIM SPACE REVISIONS REV ESCRIPTION DATE APPROVED A REVISED PER NEW TESTING 01/08/14 R.L. 3 REVISED INSTALLATION DETAILS 09/15/15 R.L, 1/4 /MAX. GVI - 45 1 -020 5/8" 1 MIN. LSHIM SPACE , REINFORCEMENT INTERIOR EDGE DISTANCE 8 SMS OR SELF DRILLING G SCREWS InnMETAL STRUCTURE BY OTHERS APPROVED EXTERIOR SEALANT - JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 0911512015 MI WINDOWS AND DOORS o\\llIl'I//// // 650 WEST MARKET STREET q, o 4f /x E N,9,.-YGRATZ, PA 17030-0370 511SERIES3240/3540 FLANGE PVC SINGLE HUNG STEEL REINFORCED WINDOW NON -IMPACT 36"x74" a ; 41 OFINSTALLATIONDETAILS 0. T A T. A 't. . w- DRANW DWG NO- REVdBTJH08-01252 L SCALE DATE SHEETNTS05/23/11 4 OF 5 CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK SEE NOTES 3-7 SHEET I APPROVED SEALANT EXTERIOR 2 1/2" MIN. EDGE DISTANCE 14 1/4 MAX. SHIM SPACE 3/16" TAPCON RF- 1 04S-020 R INFORCEMENT GVL-451 -020 REINFORCEMENT colflo I'll REVISIONS REV DESCRIPTION DATE I APPROVED A REVISED PER NEW TESTING 01/08/14 Rl, B REVISED INSTALLATION DETAILS 09/15/15 RT, 1 1/4" MIN, EMBEDMENT 1. 1/4" MIN, EMBEDMENT I CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK SEE NOTES 3-7 SHEET 1 3/16" TAPCON GVL-451 -020 REINFORCEMENT SILL TO BE SET APPROVED SEALANT IN A BED OF APPROVED CONSTRUCTION ADHESIVE 1/4 MAk OPTIONAL 1X BUCK SHIM SPACE SEE NOTES 3-7 SHEET 1 CONCRETE/MASONRY BY OTHERS 4 14 VERTICAL CROSS SECTION CONCRETEIMASONRYINSTALLATION I ' I: - I- 2 1/2" MIN. EDGE DISTANCE EXTERIOR APPROV'L' SEALANT JAMB INSTALLATION DETAIL CONCRETEIMASONRY INSTALLATION 1/4 MAX, SHIM SPACE GVL-451 -020RFREINFORCEMENTIINTERIOR NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARRY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TOBE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 0911512015 MI WINDOWS AND DOORS o kIII'll/// /// 650 WEST MA RKET STREET F. L o4f E lv,9. GRATZ, PA 17030-0370 OP. LIP 1, SERIES 3240/3540 FLANGE PVC SINGLE HUNG 0 511 '. * STEEL REINFORCED WINDOW NON -IMPACT 36"x74" 1 41INSTALLATIONDETAILS7p; TMV %A'r, 0. .1 __ DRAWN: DWG NO. EV TJH 08-01252 SCALE NTS I—E 05/23/11 Is"E"5 OF 5 111111 00 NOTES: 1 . THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE IX BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM, SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd 1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14 FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #6 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. IREVISIONS I I REV DESCRIPT10N DATE I APPROVED 15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #8 sms OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT. 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. C. MASONRY STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE I (OR GREATER). D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 5063—T5 1/8" THICK MINIMUM 20. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN IN SHEET 2. GEOMETRIC SHAPES ARE NOT LIMITED TO SHAPES SHOWN HEREIN. I TABLE OF CONTENTS I SHEET NO. 1 DESCRIPTION 1 1 NOTES 2 ELEVATIONS 3 — 7 INSTALLATION DETAILS SIGNED: 0911412015 MI WINDOWS AND DOORS oklilli'll/// /// 650 WEST MARKET STREET Vk L 04f GRATZ, PA 17030-0370 0SERIES3500 & 3540 FIXED WINDOW 811, -IMPACTX63" NON NOTES 0. T A 0 F' A. 1000t-;$- x rb DRAWN OWG NO. REV 1N. G. 08-02818 At ;e 1 1/0111110\\\ SCALE NITS DATE 9/13/12 SHEET 1 OF 7 81" MAX, FRAME WIDTH 63" MAX. FRAME HEIGHT SERIES 3500 & 3540 FIXED WINDOW EXTERIOR VIEW FINLESS & FLANGE INSTALLATION DESIGN PRESSURE RATING IMPACTRATING 35.OPSF NONE NOTES: 1. MAXIMUM D.L.O.: 77 1/8" X 59 1/8" 2 (2) 1" X 1/8" WEEPSLOT AT 2" FROM EDGE OF SILL FACE i 3" MAX. T 18" MAX 0. C. I i MAX. T F HI REVISIONS DESCRIPTION 81" MAX. FRAME WIDTH MAX. 10" MAX. 0 C. 2" T lo" 0 . c i3" AX. AME ICHT SERIES 3500 & 3540 FIXED WINDOW EXTERIOR VIEW FININSTALLATION DESIGN PRESSURE RATING IMPACTRATING 50.OPSF NONE MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 3500 & 3540 FIXED WINDOW 81" X 63" NON —IMPACT ELEVATIONS I DWG NO, N. G. 1 08-02818 SCALE NTS I DATE 9/13/12 1 SIEET 2 OF 7 DATE I APPROVED AX. 2" MAX. AX I MAX. SIGNED: 0911412015 0%11111.111ilell01 E Nq Ao 951 TATE OF zz I II I 10\ REVISIONS DESCRIPTION DATE I APPROVED 1 1/4" MIN. 1/4" MAX WOOD FRAMING 1/4" MAX. EMBEDMENT SHIM SPACE OR 2X BUCK BY OTHERS METAL SHIM SPACE INTERIOR STRUCTURE i BY OTHERS 7/16" MIN. APPROVED EDGE DISTANCE SEALANT BACKER ROD IAPPROVED1/4" MAX. SEALANT SHIM SPACE B WOOD HEAD TO BE SET SCREW HEAD TO BE SET IN A BED OF IN A BED OF APPROVED SEALANT APPROVED SEALANT WOOD FRAMING EXTERIOR BACKER ROD APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS m INTERIOR EXTERIOR INTERIOR BY OTHERS EXTERIOR BACKER ROD SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. BACKER ROD APPROVED SHIM SPACE SEALANT METAL STRUCTURE BY OTHERS VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SILL TO BE SET VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION APPROVED SEALANT JAMB INSTALLATION DETAIL IN A BED OF WOOD FRAMING OR 2X BUCK INSTALLA TION APPROVED SEALANT 1/4" MAX. SHIM SPACE 1/4 MAX. SHIM SPACE INIERIOR 5/8 MIN EDGE DISTANCE 1 8 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS BACKER ROD EXTERIOR APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 0911412015 MI WINDOWS AND DOORS 650 WEST MARKET STREET R. to 6 E IVyGRATZ, PA 17030-0370 0 951,9SERIES3500 & 3540 FIXED WINDOW 81 " X 63" NON -IMPACT 41FINLESSINSTALLATIONDETAILS TA OF',t.:Z 0. .1 - Ire U., 0 R VID '17F ' DRAWN: DWG NO. REV N.G. 08-02818 SCALE NTS :EE 9/13/12 ISIE-3 OF 7 CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK 4 SEE NOTES 3 — 7 SHEET 1 BACKER ROD APPROVED 1/4" MAX. SEALANT SHIM SPACE HEAD TO BE SET IN A BED OF APPROVED SEALANT EXTERIOR INTERIOR SILL TO BE SET BACKER ROD IN A BED OF APPROVED APPROVED SEALANT SEALANT 1/4" MAX. OPTIONAL 1X BUCK SEE NOTE 3 — 7 SHIM SPACE SHEET 1 CONCRETE/MASONRY BY OTHERS 4 14 4 VERTICAL CROSS SECTION CONCRE'EIMASONRY INSTALLATION 0 IREVISIONS I REV DESCRIPTION I DAVE I APPROVEC CONCRETE/MASONRY 1 1/4" MIN, BY OTHERS EMBEDMENT OPTIONAL 1X BUCK 1/4" MAX, SEE NOTES 3 — 7 SHIM SPACE SHEET I 3/16" TAPCON INTERIOR 2 1/2" MIN. EDCE DISTANCE BACKER ROD EXTERIOR APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETEIMASONRYINSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERmETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 3500 & 3540 FIXED WINDOW 81" X 63" NON -IMPACT FINLESS INSTALLATION DETAILS DRAWN llWG 10 N.G. 08-02818 ISCALE NTS I DATE 9/13/12 1 SHEET 4 OF 7 SIGNED: 0911412015 IT'A OF I In 0 10, WOOD FRAMING OR 2X BUCK BY OTHERS METAL STRUCTURE BY OTHERS B 7 v_ APPROVED BACKER ROD SEALANT APPROVED H ixTMIX SEALANT SHIM SPACE HEAD TO BE SET IN A BED OF APPROVED SEALANT EXTERIOR BACKER ROD APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS EXTERIOR INTERIOR SILL TO BE SET IN A BED OF APPROVED SEALANT BACKER ROD 1/4" MAX. & APPROVED SHIM SPACE SEALANT METAL STRUCTURE BY OTHER. VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2 PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 REVISIONS DESCRIPTION DATE I APPROVED 1 1/4" MIN, 1/4" MAX, 1/4" MAX. EMBEDMENT SHIM SPACE SHIM SPACE i- INTERIOR 7/16" MIN. EDGE DISTANCE 8 WOOD TO BE SET SCRI W BED OF AFFHOVED SEALANT WOOD FRAMING INTERIOR OR 2X BUCK EXTERIORBYOTHERS BACKER ROD VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION APPROVED SEALANT SILL TO BE SET d1ill/10 IIV,")I/iLL/i"UIV UCIMIL IN A BED OF WOOD FRAMING OR 2X BUCK INSTALLATION APPROVED SEALANT 1/4" MAX. 1/4" MAX. SHIM SPACE SHIM SPACE T_ E= 5/8" MIN INTERIOR EDGE DISTANCE 8 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS BACKER ROD EXTERIOR APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 0911412015 MI WINDOWS AND DOORS o\\IlII'I//// 650 WEST MARKET STREET C, 0 rj E NGRATZ, PA 17030-0370 0Z- .- \' - 11* SERIES 3500 & 3540 FIXED WINDOW 81" X 63" NON -IMPACT FLANGE INSTALLATION DETAILS TATrO'F 0 DRAWN: DWG NO. REV N.G. 08-02818 1 i, - - - ZONAL 0/1-111,110E9/13/12 SHEET 5 OF 7 CONCRETE/MASONRY BY OTHERS 4 OPTIONAL 1X BUCK 4 SEE NOTES 3 — 7 SHEET 1 ED BACKER ROD APPROVED 1/4" MAX. SEALANT SHIM SPACE HEAD TO BE SET IN A BED OF APPROVED SEALANT EXTERIOR INTERIOR SILL TO BE SET BACKER ROD IN A BED OF APPROVED APPROVED SEALANT SEALANT 1/4" MAX. OPTIONAL IX BUCK SEE NOTE 3 — 7 SHIM SPACE SHEET 1 CONCRETE/MASONRY BY OTHERS 4 4 4 VERTICAL CROSS SECTION CONCRETEIMASONRYINSTALLATION IREVISIONS I REV DESCRIPTION I APPROVED CONCRETE/MASONRY 1 1/4" MIN. BY OTHERS EMBEDMENT OPTIONAL 1X BUCK 1/4" MAX. SEE NOTES 3 — 7 SHIM SPACE SHEET I 3/16" TAPCON INTERIOR 2 1/2" MIN. EDGE DISTANCE BACKER ROD EXTERIOR APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETEIMASONRYINSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 3500 & 3540 FIXED WINDOW 81" X 63" NON —IMPACT FLANGE INSTALLATION DETAILS DRAWN: DWG NO. N.G. 08-02818 SCALE NTS I DATE 9/13/12 1 SHEET 6 OF 7 SIGNED: 0911412015 0\11111,1/j// 0 ",/// 0 51 0 Fr,-jo 4 '4Q 0 TAT OF v '. A, A L l/0111100 APPROVED SEALANT BEHIND FIN 6 WOOD SCREW 3/8" MIN EDGE DISTANCE EXTERIOR INTERIOR WOOD FRAMING BY OTHERS 1/4" MAX. SHIM SPACE WOOD FRAMING BY OTHERS 6 WOOD SCREW 1 1/4" MIN. EMBEDMENT T__ APPROVED SEALANT BEHIND FIN 3/8" MIN EDGE DISTANCE 1/4" MAX SHIM SPACE INTERIOR EXTERIOR JAMB INSTALLATION DETAIL 1/4" MAX WOOD FRAMING OR 2X BUCK INSTALLATION SHIM SPACE IREVISIONS . I I REV DESCRIPTION I DATE I APPROVED 3/8" MIN NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, EDGE DISTANCE 77 E MSEDMENT NOT SHOWN FOR CLARITY- 7' 6 WOOD WOOD 2. PERIMETER ANDJOINT SEALANT BY OTHERS TO BE SCREW FRAMING DESIGNED IN ACCORDANCE WITH ASTM E2112 1 1/4" MIN. BY OTHERS APPROVED SEALANT BEHIND FIN VERTICAL CROSS SECTION SIGNED: 0911412015 W06D FRAMING Of? 2X BUCK INSTALLATION MI WINDOWS AND DOORS 650 WEST MARKET STREET 0 41 GRATZ, PA 17030-0370 SERIES 3500 & 3540 FIXED WINDOW o 51 81" X 63" NON —IMPACT FIN INSTALLATION DETAILS TAT OF DRAWN: OWG NO, N. G. 08-02818 NAL I DATE I SHEISCA" NTS 9/13/12 ET7 OF 7 I tiIIIII0\ Horlda Product ApprovM CemplankO Lap Vding - 0 For use inside HVHZ: o Cemplank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami -Dade County Florida NOA 17- 0406.06. Consult the Cemplank product installation instructions on the follow pages for all other installation requirements. 0 For use outside of HVHZ, o Cemplank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Reports RIO-2683-17, RIO-2687-17, or RIO-2688-17. Consult the Cemplank product installation instructions on the follow pages for all other installation requirements. Lap Siding INSTALLATION REQUIREMENTS - PRIMED AND FACTORY BUILT COLOR TREATED PRODUCTS NOVEMBER 2016 CEDAR - BEADED CEDAR - BEADED SMOOTH IMPORTANT FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND THE MANUFACTURER'S WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY. STORAGE & HANDLING: CUTTING INSTRUCTIONS* Store flat and keep dry and covered prior OUTDOORS equipped with a HardieBladell saw INDOORS to installation. Installing product wet or 1. Position cutting station so that wind blade and vacuum dust extraction 1. NEVER cut with power saws indoors saturated may result in shrinkage at butt will blow dust away from user and others in working area. c. Good: Circular saw with a 2. Cut only using score and snap. or shears (manual, joints. Carry product on edge. Protect HardleBlade saw blade (for low to electric or pneumatic). edges and corners from breakage. 2. Use one of the following methods: moderate cutting volume) 3. Position cutting station in well -ventilated area CemboardO is not responsible for damage a. Best: I. Score and snap I. Shears caused by improper storage and manual, electric or pneumatic)* b. Better: Dust reducing circular saw Shears and score/snap methods may not be suitable for products thicker than 1/2 in. NEVER dry sweep — Use wet suppression or Vacuum handling of the product, NIOSH-appruved respirato(sGan beused in conjunction with aboveculting practices to further reduce dust exposures. Additional exposure information isavailablea5patwww.jameshardie.com to help you determine the most appropriate cutting method for your job requirements. If concern still exists about exposure levels or you do not comply with the above practices, you should always consult a qualified industrial hygienist or contact the manufacturer for further information. SM105 GENERAL REQUIREMENTS: Cemplanke lap siding can be installed over braced wood or steel studs spaced a maximum of 24 in. o.c. or directly to minimum 7/16 in. thick OSB sheathing. See general fastening requirements. Irregularities in framing and sheathing can mirror through the finished application, Information on installing Cemboard products over foam can be located in JH Tech Bulletin 19 at www. iamehardie.com A water -resistive barrier is required in accordance with local building code requirements. The water -resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. Cemboard will assume no responsibility for water infiltration. James Hardie does manufacture HardieWrap" Weather Barrier, a non -woven non -perforated housewrap', which complies with building code requirements. When installing Cemboard products all clearance details in figs. 3-14 must be followed. Adjacent finished grade mist slope away from the building in accordance with local building codes - typically a minimum of 6 in. in the first 10 ft.. Do not use Cemplank lap siding in fascia or trim applications. Do not install Cemboard products, such that they may remain in contact with standing water Cemplank lap siding may be installed on flat vertical wall applications only. Figure 1 Double Wall Single Wall Construction Construction For larger projects, including commercial and multi -family projects, where the span of the water -resistive barrier let -in bracing wall is significant in length, the designer and/or architect should take into consideration the plywood or 24 in. o.c. ax. coefficient of thermal expansion and moisture movement of the product in their design, OSB sheathing These values can be found in the Technical Bulletin "Expansion Characteristics of Cemboardo Siding Products" at www.JamesHardie.com, DO NOT use stain, oil/alkyd base paint, or powder coating on Cemboard" Products. INSTALLATION: JOINTTREATMENT One or more of the following joint treatment options are required by code (as referenced 2009 IRC R703.10.2) A. Joint Flashing (Cemboard recommended) B. Caulking* (Caulking is not recommended for Factory Built Color for aesthetic reasons as the Caulking and Factory Built Color will weather differently. For the same reason, do not caulk nail heads on Factory Built Color products.) C. "H" jointer cover Figure 2 Place fastener between 3/4 in. & 1 " from top of plank moueraie cornaci ai ourf joints Refer to Caulking section in these instructions. I For additional information on HardieWrap` Weather Barrier, consult Cemboard at 11-866-41-lardie or www.hardiewrap.com barrier 60 fastener 0 Install a 1 1/4 in. starter strip to ensure a consistent plank angle 0 leave appropriate gap between planks and trim, then caulk. — DANGER: Do not breathe dust Fiber cement Is nat a hasen heceard Wien handled orstered in hasniginal, tervalteradcondifion. The hawd associated Mh fiber cement arl from crystalline sitice present m the dust generated by activitfin axh assuffing, nothating, drilling, from this pmduct. Respirable rocurg, savving, creshing, a otherwise manning fiber ceravern, and when cleaning up, c1sposIng of or moong the dust. When doing arN of these acMies, in a manner that generates dust: (1) follm James Hudie inShMns and best practices 0 racce. or linalt the releaSe of dust; (2) Wam others ha the am to avoid the cust; 13) when using mechanical saw or high speed cutting tools, vvA outdoors and we dust eDilectim equipment; and (4) If no other dust controls ue avallable, vmi a Crystalline Silica Dust causes M10SH-appruved dust mak or respirator te g., Me N 95 dust =A damage to lungs and respiratory Refer to the product Safety Data Sheet before me. Do act handle product until all safety precautions have been read and understood. Wash fivands and face thoresughyrafter handing. If eVesed to dust orcriecemsed, got medical advIce. ft shadiness system through prolonged of breath or other health corcerns davelop after equasum to dust been the product, seek medical attention. Disposer Of proded M accordance fth ", Me and national regulators. If there are rat applicable regifilLailicars, dspm of in a secum, or repeated inhalation. andfill, re In a vvey that Mil not e)pose others to dust. WARNING: This product contains a chemical form to the State of California to muse cancer. F% move infornallon go to ~P651Namings.ca.gov/product. For more information contact: James Hardie Building Products, Inc., 231 S. LaSalle St., Suite 2000, Chicago, IL 60604 USA 1-888 JHARDIE www.jameshardle.com www.jhsatesfte.com CEM1610-Pl/4 11/16 South CLEARANCE AND FLASHING REQUIREMENTS Figure 3 Figure 4 Figure 5 Figure 6 Roof to Wall Horizontal Flashing Kickout Flashing Slabs, Path, Steps to Siding Figure 7 Deck to Wall Figure 12 Drip Edge Figure 8 Ground to Siding 4 in. I Figure 9 Figure 10 Gutter to Siding Sheltered Areas Figure 13 Block Penetration Recommended in HZ10) Z;Fla 71, cau in. I Figure 9 Figure 10 Gutter to Siding Sheltered Areas Figure 13 Block Penetration Recommended in HZ10) Z;Fla 71, cau n. Figure 14 Valley/Shingle Extension Figure 11 Mortar/Masonry t4lashing7,O FASTENER REQUIREMENTS ** (Please refer to the applicable ESR report online to determine which fastener meets your wind load design criteria) Blind Nailing is the preferred method of installation for Cemplanks lap siding products. Face nailing should only be used where required by code for high wind areas and must not be used in conjunction with Blind nailing (Please see JH Tech bulletin 17 for exemption when doing a repair). Pin -backed comers may be done for aesthetic purposes Only. Pin -backs shall be done with finish nails only, and are not a substitute for blind or face nailing. BLIND NAILING FACE NAILING Nails - Wood Framing Nails - Wood Framing Siding nail (0.09 in. shank x 0.221 in. HD x 2 in, long) 9 6d (0.113 in. shank x 0.267 in. HD x 2 in. long) 11 ga. roofing nail (0.121 in. shank x 0.371 in. HD x 1.25 in. long) e Siding nail (0.09 in. shank x 0.221 in. HD x 2 in. long) Screws - Steel Framing Screws - Steel Framing e Ribbed Wafer -head or equivalent (No. 8 x 1 1/4 in. long x 0.375 in. HD) Screws 9 Ribbed Bugle -head or equivalent (No. 8-18 x 1-5/8 in. long x must penetrate 3 threads into metal framing. 0.323 in. HD) Screws must penetrate 3 threads into metal framing. Nails - Steel Framing Nails - Steel Framing ET & F Panelfast! nails or equivalent (0.10 in. shank x 0.313 in. HD x 1-1/2 in. ET & F pin or equivalent (0.10 in. shank x 0.25 in. HD x 1-1/2 in. long) long) Nails must penetrate minimum 1/4 in. into metal framing. Nails must penetrate minimum 1/4 in. into metal framing. OSB minimum 7/16 in. OSB minimum 7/16 in. 11 ga. roofing nail (0.121 in. shank x 0.371 in. HD x 1.75 in. long) e Siding nail (0.09 in. shank x 0.221 in. HD x 1-1/2 in. long)* Ribbed Wafer -head or equivalent (No. 8 x 1 5/8 in. long x 0.375 in. HD). stud 24 in ----------- 1----o.c. m.. , , Z Stud 24" X "iO.C. me x Figure 15 Figure 16 1 1/4 in. min. ovedap Minimum overlap for Both Face r and Blind Nailing 3/4 in.-1 in Blind Nail (0) face nail min. 1 1/4 in. ovedap water -resistivet Water Resistive barrier I I min. Barrier ONY d Laminate sheet to be removed immediately after installation of each course for ColorPlusO products. When face nailing to OSB, planks must be no greater than 9 1/4 in. wide and fasteners must be 12 in. o.c. or less. Also see General Fastening Requirements; and when considering alternative fastening options refer to Technical Bulletin USTB 17 - Fastening Tips for Cernplane Lap Siding. CEM1610-P2/4 11/16 South GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. Cemboard recommends the use of quality, hot -dipped galvanized nails. Cemboard is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing Cemboarcla products near the ocean, large bodies of water, or in very humid climates. PNEUMATIC FASTENING Cemboard products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachment on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive under driven nails snug with a smooth faced hammer - Does not apply for installation to steel framing). Manufacturers of ACO and CA preservative -treated wood recommend spacer materials or other physical barriers to prevent direct contact of ACQ or CA preservative -treated wood and aluminum products. Fasteners used to attach countersunk, HardieTrim Tabs to preservative -treated wood shall be of hot dipped fill X nrld nnil zinc -coated galvanized steel or stainless steel and in accordance to 2009 IRC snug R317.3 or 2009 IBC 2304.9.5. Consult applicable product evaluation or listing for correct fasteners type and placement to achieve specified design wind loads. NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction. Consult Cemboard Technical Services if you are unsure of applicable compliance documentation. Drive fasteners perpendicular to siding and framing. Fastener heads should fit snug against siding (no air space). (fig. A) Do not over -drive nail heads or drive nails at an angle. If nail is countersunk, fill nail hole and add a nail. (fig. B) For wood framing, under driven nails should be hit flush to the plank with a hammer (For steel framing, remove and replace nail). Do not use aluminum fasteners, staples, or clipped head nails. FACTORY BUILT COLOR CAULKING, TOUCH-UP & LAMINATE Figure A I Figure B PAINTING 4F N QP 0 DO NOT DO NOT under drive nails staple DO NOT use stain, oil/alkyd base paint, or powder coating on CImbludO Products. Cemboard products must be painted within 180 days for primed product and 90 days for unprimed. 100% acrylic topcoats are recommended, Do not paint when wet, For application rates refer to paint manufacturers specifications. Back -rolling is recommended if the siding is sprayed. CUT EDGE TREATMENT Caulk, paint or prime all field cut edges. CAULKING For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTIM C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note: Some caulking manufacturers do not allow tooling. Care should be taken when handling and cutting Cemboard" Factory Built Color products. During installation use a Wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product, then rinse with a garden hose. Touch up nicks, scrapes and nail heads using the Factory Built Color touch-up applicator Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with new Cemplanko lap siding with Factory Built Color. Laminate sheet must be removed immediately after installation of each course. Terminate non -factory cut edges into trim where possible, and caulk. Color matched caulks are available from your Factory Built Color product dealer. Treat all other non -factory cut edges using the Factory Built Color edge coaters, available from your Factory Built Color product dealer. Note: Cemboard does not warrant the usage of third party touch-up or paints used as touch-up on Cemboard Factory Built Color products. Problems with appearance or performance arising from use of third partytouch-up paints or paints used as touch-up that are not Cemboard touch-up will not be covered under the Cemboard Factory Built Color Limited Finish Warranty. RE -PAINTING CEMBOARD11 SIDING AND TRIM PRODUCTS WITH FACTORY BUILT COLOR When repainting Factory Built Color products, Cemboard recommends the following regarding surface preparation and topcoat application: Ensure the surface is clean, dry, and free of any dust, dirt, or mildew Repriming is normally not necessary 100% acrylic topcoats are recommended Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature CEM1610-P3/4 11/16 South COVERAGE CHART/ESTIMATING GUIDE Number of 12 ft. planks, does not include waste COVERAGE AREA LESS OPENINGS I CEMBOARDO LAP SIDING WIDTH so 51/4 61/4 71/4 71/2 8 81/4 91/4 91/2 12 ISQ=100sq.fL) exposure) 4 5 6 61/4 63/4 7 8 81/4 103/4 1 25 20 17 16 15 14 13 13 9 2 50 40 33 32 30 29 25 25 19 3 75 60 50 48 44 43 38 38 28 4 100 80 67 64 59 57 50 50 37 5 125 100 83 80 74 71 63 63 47 6 150 120 100 96 89 86 75 75 56 7 175 140 117 112 104 100 88 88 65 8 200 160 133 128 119 114 100 100 74 9 225 180 150 144 133 129 113 113 84 10 250 200 167 160 148 143 125 125 93 11 275 220 183 176 163 157 138 138 102 12 300 240 200 192 178 171 150 150 112 13 325 260 217 208 193 186 163 163 121 14 350 280 233 224 207 200 175 175 130 15 375 300 250 240 222 214 188 188 140 16 400 320 267 256 237 229 200 200 149 17 425 340 283 272 252 243 213 213 158 18 450 360 300 288 267 257 225 225 167 1 9 475 380 317 304 281 271 238 238 177 20 500 400 333 320 296 286 250 250 186 This coverage chart is meant as a guide. Actual usage is subject to variables such as building design. Cemboard does not assume responsibility for over or under ordering of product. RECOGNITION: In accordance with ICC-ES Evaluation Report ESR-2290, Cemplank(D lap siding is recognized as a suitable alternate to that specified in: the 2OD6,2009,&2012 International Residential Code for One- and Two -Family Dwellings, and the 2006,2009, & 2D12 International Building Code,. Cemplank lap siding Is also recognized for application In the following; City of Los Angeles Research Report Na. 24862, State of Florida listing FL#889, Dade County, Florida NOA No. 02-0729.02, U.S. Dept of HUD Materials Release 1263c, Texas Department of Insurance Product Evaluation EC-23, City of New York MEA 223-93-M, and California DSA PA-019. These documents should also be consulted for additional information concerning the suitability of this product for specific applications. @ 2016 JHIF B.V. All rights reserved. TIVI, SM, and @ denote Additional Installation Information, trademarks or registered trademarks of JHIF B.V. Warranties, and Warnings are available at www.cemboardsiding.com CEM1610-P4/4 11/16 r Florida Product Approval HardieSoffitO Panel For use inside HVHZ: o HardieSoffit Panel fastener types, fastening schedule, and installation shall be in accordance with the Miami -Dade County Florida NOA 17-0406.06. Consult the HardieSoffit product installation instructions on the follow pages for all other installation requirements. For use outside of HVHZ, o HardieSoffit Panel fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Report RIO-2684-17. Consult the HardieSoffit product installation instructions on the follow pages for all other installation requirements. HardleSoff it'AK.12. Panels JamesHardie EFFECTIVE SEPTEMBER 2013 FM INSTALLATION REQUIREMENTS - PRIMED & COLORPLUSO PRODUCTS Visit www.'ameshardie,com for the most recent version. IMPORTANT. FAILURETO INSTALLAND FINISH THIS PRODUCT IN ACGORDANCEW1TH APPLJCABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY. BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS. INSTALLATION OF HZ10TM PRODUCTS OUTSIDE AN HZ1 00 LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONE APPLIES TO YOUR LOCATION. VISrr WWW.HARDIEZONE.COM OR CALL 1-866-942-7343 STORAGE & HANDLING: 2 CUTTING INSTRUCTIONS Store flat and keep dry and covered prior OUTDOORS INDOORS to installation. Installing siding wet or 1, Position cutting station so that wind will blow dust away from user 1. Cut only using score and snap, or shears (manual, electric or pneumatic). saturated may result in shrinkage at butt and others in working area. 2. Use one of the following methods: 2. Position cutting station in well -ventilated area joints. Carry product on edge. Protect a. Best: I. Score and snap edges and corners from breakage. James ii. Shears (manual, electric or pneumatic) NEVER use a power saw indoors Hardie is not responsible for damage b. Better. I. Dust reducing circular saw equipped with a NEVER use a circular saw blade that does not carry the HardieBlade saw blade trademark caused by improper storage and handling HardleBladeP saw blade and HEPA vacuum extraction NEVER dry sweep — Use wet suppression or HEPA Vacuum of the product. c. Good: i. Dust reducing circular saw with a HardieBlade saw blade only use for low to moderate cuffing) Important Note: For maximum protection 0owest respirable dust production), James Hardie recommends always using 'Besf'-Ievel cutting methods where feasible. NIOSH-approved respirators can be used in conjunction with above cutting practices to further reduce dust exposures. Additional exposure inforiTtation is available 0 at www.jameshardie.com to help you determine the most appropriate cutting method for your job requirements. If concern still exists about exposure levels or you do not comply with the above practices, you should always consult a qualified industrial hygienist or contact James Hardie for further information. SDM3105 GENERAL REQUIREMENTS: HardieSoffP panels maybe installed over either steel or wood framing complying with the local building code. See general fastener requirements. Install soffits to nominal 2 x 4 framing members spaced a maximum of 24 inches on center (fig,4), All edges must be supported by framing. (figs. 3 & 4) Install water barriers and air barriers as required by local building codes. James Hardie will assume no responsibility for moisture infiltration. Ensure gutters have end caps. Maintain a minimum 1 " gap between end caps and siding & trim (fig.5). Install kickout flashing at roof -wall junctions. (fig 6.) Figure 1 DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardiee Products. INSTALLATION: F7/7/E=- HardieSoffit panels must be fastened to a solid, nailable substrate such as a wood 2x subfascia. Additional framing may be needed to ensure proper fastening. Soffits can be installed as shown in figure 1. Position the vent holes toward the outside of the eave for optimal airflow. 12" to 24" wide Vented HardieSoffit panels, provide 5.0 square inches of net free ventilation per lineal foot. Alternatively vents can be installed into non -vented soffit. If necessary, an insect screen can be installed using construction adhesive. Note: net free ventilation will be reduced. Fastener Requirements e Position fasteners 3/8" from panel edges and no closer than 2" away from corners when using soffit greater than 12" wide (fig. 4) and no closer than 1 " away from corners when using soffit that is less than or equal to 12" wide (fig. 3). Jointing Methods e Install panels in moderate contact at ends, provide PVC or metal jointers, battens or leave appropriate gap and caulk (fig 2)' Figure 2 Figure 3 framing member moderate contact framing member H-jointer framing framing member mem her leave appropriate gap batten and caulk less than or equal to 12" Wide Soffit ventinb to outside of ea shim fascia (wood) HardieSoffit subtascia vented panel from end of soffit 3/8" from edge of soffit For additional information on HardieWraDlm Weather barrier. consult James Hardie at I -bbb-41darclie or www. WARNING: "OID BREATHING SILICA DUST siding Figure 4 Greater than 12" Wide Soffit keep fasteners 2" away from corners 3/8" from edge of soffit James Hardie* products contain respirable crystalline silica, which is known to the State of California to cause cancer and is considered by IARC and NIOSH to be a cause of cancer from some occupational sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis, and has been linked with other diseases. Some studies suggest smoking may increase these risks. During installation or handling: (1) work in outdoor areas with ample ventilation; (2) use fiber cement shears for cutting or, where not feasible, use a HardieBlade saw blade and dust -reducing circular saw attached to a HEPA vacuum; (3) wam others in the immediate area; (4) wear a properly -fitted, NIOSH-approved dust mask or respirator (e.g. N-95) in accordance with applicable government regulations and manufacturer instructions to further limit respirable silica exposures. During clean-up, use HEPA vacuums or wet cleanup methods - never dry sweep. For further information, reter to our installation instructions and Material Safety Data Sheet available at www.jameshardie.com or by calling 1-800-9HARDIE (1 -800-942-7343). FAJLURE TO ADHERE TO OUR WARNINGS, MsDS, AND INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH. SF1203-Pl/3 6/13 Maintain a minimum 1 " gap between gutter end capsand siding & trim. sidinj Figure 5 gutter and end cap Figure 6 FASTENER REQUIREMENTS e For wood frame construction a minimum 4d common nails spaced 8" o.c. at panel edges and intermediate framing members spaced up to 24" on center are suitable in most locations*. e For conventional 20ga steel frame construction a minimum No. 8-18 x 0.323" HD x 1 " long ribbed bugle screws spaced 6" o.c. at panel edges and intermediate framing members spaced up to 24" on center are suitable in most locations**. Minimum Basic Wind Speed differs by locality. Where specified levels of wind resistance are required, refer to applicable Building Code Compliance Reports. PNEUMATIC FASTENING James Hardie products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount allachment on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive under driven nails snug with a smooth faced hammer - Does not apply for installation to steel framing). A-Fzf-#. KICKOUT FLASHING Because of the volume of water that can pour down a sloped roof, one of the most critical flashing details occurs where a roof intersects a sidewall. The roof must be flashed with step flashing. Where the roof terminates, install a kickout to deflect water away from the siding. It is best to install a self -adhering membrane on the wall before the subfascia and trim boards are nailed in place, and then come back to install the kickout. Figure 6, Kickout Flashing To prevent water from dumping behind the siding and the end of the roof intersection, install a "kickout" as required by IRC code R905.2.8.3 : "...flashing shall be a min. of 4" high and 4" wide." James Hardie recommends the kickout be angled between 1000 - 1100 to maximize water deflection GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot -dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James HardieO products near the ocean, large bodies of water, or in very humid climates.. Consult applicable product evaluation or listing for correct fasteners type and placement to achieve specified design wind loads, NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable compliance documentation. Drive fasteners perpendicular to siding and framing. Fastener heads should fit snug against siding (no air space). (fig. A Do not over -drive nail heads or drive nails at an angle. If nail is countersunk, fill hole and add a nail. (fig. B) For wood framing, under driven nails should be hit flush to the plank with a hammer (For steel framing, remove and replace nail). Do not use aluminum fasteners, staples, or clipped head nails. M4211: Figure A Countersink, Fill &Add Nail Figure B Z\ QP 0 do not under DO NOT drive nails STAPLE SF1203-P2/3 6/13 CUT EDGE TREATMENT Caulk, paint or prime all field cut edges. James Hardie touch-up kits are required to touch-up ColorPlus products. CAULKING For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade INS, Class 25 or higher or a Latex Joint Sealant complying with ASTIVI C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note: OSI Quad as well as some other caulking manufactuers DO NOT allow tooling. COLORPLUS11 TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE PAINTING DO NOT use stain, oiValkyd base paint, or powder coating on James HardjeO Products. James Hardie products must be painted within 180 days for primed product and 90 days for unprimed. 100% acrylic topcoats are recommended. Do not paint when wet. For application rates refer to paint manufacturers specifications. Back -rolling is recommended if the siding is sprayed. Care should be taken when handling and cutting James Hardie ColorPlus products. During installation use a wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product, then rinse with a garden hose. Touch up nicks, scrapes and nail heads using the ColorPlus' Technology touch-up applicator Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with new HardieSoffito panel with ColorPlus Technology. Laminate sheet must be removed immediately after installation of each course. Terminate non -factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus dealer. Treat all other non -factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus* product dealer. ote: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up, will not be covered under the James Hardie ColorPlus Limited Finish Warranty. PAINTING JAMES HARDIP PRODUCTS WITH COLORPLUSO TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: Ensure the surface is clean, dry, and free of any dust, dirt, or mildew Repriming is normally not necessary 100% acrylic topcoats are recommended DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardiea Products Apply finish Goat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section RECOGNITION: HardieSoffit Panel complies with ASTM C1 186 in so doing meets the Fiber -Cement Siding code requirements in the 2006 Intemational Building Gode@ Section 1404.10 and 1405.15, the 2009/12 International Building Code Section 1404.10 and 1405.16 ; and the 2006/09/12 International Residential Code@ for One- and Two -Family Dwellings Table R703.4 and section R703.1 0. Hardlesoffit panel is also recognized for application in the following: State of Florida ProductApproval I'Ll 3265, Dade County, Florida NOA No. 13-0311.07, U.S. Dept. of HUD Materials Release 1263, Texas Department of Insurance Product Evaluation EC-23, City of New York MEA 223-93-M, and California DSA PA-01 9, These documents should also be consulted for additional information concerning the suitability of this product for specific applications 0,2013 James Hardie Building Products, Inc, All rights reserved. Additional Installation Information, n ffieTIMSM, and 0 denote trademarks or registered trademarks of James Hardie Technology Limited. Illis a registered trademark Warranties, and Warnings are available at James"ara of James Hardie Technology Limited. www.jameshardie.com SF1203-P3/3 6/13 Certificate of Authorization No. 29824 17520 Edinburgh Drive8040" R E E K Tampa, FIL 33647 TECHNICAL SERVICES, LLC ( 813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6 T" EDITION (2017) Manufacturer: MID -STATES ASPHALT AND CANT STRIP, INC. Issued October 11, 2017 1637 51s' Street Tuscaloosa, AL 35401 800) 489-2391 www.msaroof.com Manufacturing Location: Tuscaloosa, AL Quality Assurance: LIL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1. 1507.1.1 Properties: Physical properties PRODUCT DESCRIPTION AND LIMITS OF USE QUIK-Stick Ice & Water QUIK-Stick Ice & Water Granular is an ASTM D 1970 self-adhesive underlayment Granular constructed from SIBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 50 mils. QUIK-Stick Ice & Water Granular is permitted to be used as prescribed in FIBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick Ice & Water QUIK-Stick Ice & Water Sand is an ASTM D 1970 self-adhesive underlayment Sand constructed from SBS modified asphalt with a fiberglass mat reinforcement and surfaced with sand. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 50 mils. QUIK-Stick Ice & Water Sand is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick HT QUIK-Stick HT is an ASTM D 1970 self-adhesive underlayment constructed from SIBS High Temperature) modified asphalt with a fiberglass mat reinforcement and poly -fabric surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft or 3-ft 3-in x 61- ft and has a nominal thickness of 60 mils. QUIK-Stick HT is to be used as prescribed in FIBC Section 1507.1.1. QUIK-Stick HT is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 612. Tiles shall not be stacked greater 10 tiles per stack. . MSA17001 FL17401-R4 Paoe 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MID -STATES ASPHALT AND CANT STRIP, INCCREEKSelf -Adhering UnderlaymentsITECHNICALSERVICES, LLC QUIK-Stick HT Pro QUIK-Stick HT Pro is an ASTM D 1970 self-adhesive underlayment constructed from High Temperature) SBS modified asphalt with a fiberglass mat reinforcement and poly -fabric surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 60 mils. QUIK-Stick HT Pro is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick FS QUIK-Stick FS is an ASTM D 1970 self-adhesive underlayment constructed from SBS Film Surface) modified asphalt with a fiberglass mat reinforcement and textured film surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 45 mils. QUIK-Stick FS is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. PRODUCT APPLICATION Min. Roof Slope: 2:12 or in accordance in with the FBC Application: All underlayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6" end laps staggered min. 6-ft.frorn preceding course. It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Min. Application 40*F- Contact the manufacturer when installing at temperatures below the minimum Temperature: appli ation temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No. 1 — QUIK-Stick HT only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: QUIK-Stick HT shall be fully adhered to the optionally primed plywood deck. Maximum Design -52.5 psf Pressure: MSA17001 FL17401-R4 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MID -STATES ASPHALT AND CANT STRIP, INCCREEKSelf -Adhering Underlayments TECHNICAL SERVICES, LLC GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FIBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. REFERENCES Enigy Report No. Standard Year PRI Construction Materials Technologies (TST5878) BWR-514-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) BWR-522-02-01 ASTIVI D 1970 2015a PRI Construction Materials Technologies (TST5878) BWR-533-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) BWR-534-02-01 ASTM D 1970 2015a ASTIVI D 4798 2011(2016) PRI Construction Materials Technologies (TST5878) BWR-543-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) WRMI-01 1-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA-026-02-01 ASTM D 1970 2015a MSA17001 FL17401-R4 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT MID -STATES ASPHALT AND CANT STRIP, INC Self -Adhering Underlayments The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6 th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. j1IIIIIIII, 00 R CENS*.. No 74021 ir Z 33 STATE OF .:441 0 R C> 8/0 ' NA\_ CERTIFICATION OF INDEPENDENCE 2017.10.11 11:41:31 04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT MSA17001 FL17401-R4 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. SpL=c1canij StrLic:turc5l E=nqlnL=L=rinq CBUCK, Inc. Certificate of Authorization #8064 Evaluation Report 5V Crimp" & "Millennium-V" Metal Roof Assembly Manufacturer: Millennium Metals, Inc. 10200 Eastport Road Jacksonville, FL 32218 877) 358-7663 for Florida Product Approval FL 5211.1 R7 Florida Building Code 6th Edition (2017) Per Rule 61G20-3 Method: 1 - D Category: Roofing Sub - Category: Metal Roofing Product: Material: Panel Thickness: Panel Width: Support: Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer# 31242 Florida Evaluation ANE ID: 1916 Report No. 17-196-5V-S6W-ER Revises 15-104-5V-S6W-ER) Date: 10 / 16 / 17 Contents: Evaluation Report Pages 1 — 8 5V Crimp" & "Millennium-V" Steel 26 gauge (Minimum) 241) Facsimile of digital copy signed by Wood Deck James L. Buckner, P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule 61G15-23. Uj CE No 31242 0 LU Z 0 41/ Y' STATE OF Z_ 2017.10.19 20:13:36 -04'00' CBUCK, Inc. — Palm Beach County, Florida Phone: (561) 491-9927. Email: cbuck@cbuckinc.net - Website: www.cbuckinc.net Main Office: 1374 Community Drive, Jupiter, Florida 33458 FL #: Fl. 5211.1-117 Date: 10/16/17 Report No.: 17-196-5V-S6W-ER Page 2 of 8 SpeciaN Structural L-ngineearing CBLICK, Inc. Certificate of Authorization #8064 Manufacturer: Product Name: Product Category: Millennium Metals, Inc. SV Crimp" & "Millennium-V" Roofing Product Sub -Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product/System "5V Crimp" & "Millennium-V" Description: 26 gauge (Minimum Thickness) Steel roof panel mechanically attached to Plywood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & standards: Evaluated: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation (Optional) Support: Type: Wood Deck Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: 0 15/32 (min.) or 19/32" (min.) or greater plywood, (See Table "A") 0 or Wood plank (min. specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: o Design Uplift Pressure: Refer to Table A Refer to "Table A" attachment details herein) FL #: FL 5211.1-117 Date: 10/16/17 01'E25UMFCOI Enc2inenering Report No.: 17-196-5V-S6W-ER Page 3 of 8 Specle-iftj Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Performance Standards: The product described herein has demonstrated compliance with: UL580-06 — Testfor Uplift Resistance of Roof Assemblies UL 1897-12 — Uplift testfor roof covering systems TAS 125-03 — Standard Requirementsfor Metal Roofing Systems Standards Equivalency: 0 The UL 580-94 standard version used to test the evaluated product assembly is equivalent to UL580-06 standard version adopted by the Florida Building Code 6th Edition (2017). The UL 1897-98 standard version used to test the evaluated product assembly is equivalent to UL1897-12 standard version adopted by the Florida Building Code 6th Edition (2017). Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 6th Edition (2017), Section 1504.3.2. Evaluation Report Scope: This product evaluation is limited to compliance with the structural requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and Scope of "Limitations and Conditions of Use" for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. All metal components and fasteners shall be corrosion resistant in accordance with applicable sections of FBC, including but limited to Sections 1504.3.2, 1506.6 and 1507.4.4. Design of support system is outside the scope of this report. Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA 1824). FIL #: FIL 5211.1-117 Date: 10/16/17 Report No.: 17-196-5V-S6W-ER Page 4 of 8 Specle-oIN Structurc=-il Engineering CBUCK, Inc. Certificate of Authorization #8064 Components/Materials Roof Panel: by Manufacturer): Product Identification: "5V Crimp" & "Millennium-V" Material: Steel Thickness: 26 gauge (min.) Panel Width: 24" (max.) Coverage Rib Height: 7/16" Yield Strength: 40 ksi min. Corrosion Resistance: In compliance with FBC Section 1507.4.3: ASTIVI A792 coated, or ASTM A653 G90 galvanized steel Fastener A: Type: Hex -Head Wood Screw with WSW Size: #9 (x length to meet min. penetration through deck) Penetration Through: 3/16" min. through wood deck Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.4 Fastener B: Type: Hex -Head Wood Screw with WSW Size: #10 (x length to meet min. penetration through deck) Penetration Through: 3/16" min. through wood deck Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.4 Components/Materials Underlayment: by Others): Material and application shall be in compliance with FBC Section 1507.1.1 and in accordance with applicable code sections and manufacturer's recommendations. Insulation (Optional): Type: Thickness: Properties: Density: Or Compressive Strength: Rigid Insulation Board 3" (max.) 2.25 pcf (IbS/ft3) min. 20 psi min. Insulation Notes: Rigid Insulation shall meet minimum density OR compressive strength. Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16-. A64,01 =(!.! (K& r - te-- - I 1; -rliragn11 FL #: FL 5211.1-117 Date: 10/16/17 Report No.: 17-196-5V-S6W-ER Page 5 of 8 ISpeclaltij Structurall Encgineering CBUCK, Inc. Certificate of Autharization #8064 installation: Installation Method: Refer to "TABLE A" below and drawings at the end of this evaluation report.) Fastener spacing: Refer to Table "A" Below along the length of the panel) Row Spacing: Refer to Table "A" Below along the row, across the panel profile) Rib Interlock: Lapped Minimum fastener penetration thru bottom of support, 3/16". For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: METHOD 3: METHOD 4: Design Pressure: 112.5 PSF 113.75 PSIF 45 PSF 93.75 PSF Deck Thickness: 19/32- 15/32" 15/32" 15/32- Fastener Size: 9 9 10 10 Row Spacing: 12" 12" 24" 12" Fastener Spacing: 1211 611 12" 12" Fastener Location: Corrugation Peaks Corrugation Peaks between ribs Corrugation Peaks Corrugation Peaks Refer to Drawing #: A-1 & A-2 2B-1 & B I A-1 &A -2 A-1 & A-2 Allowable design pressure for allowable stress design (ASD) with a margin of safety of 2 to 1. Install the "5V Crimp or Millennium V" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition 2017). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL580-94 & UL 1897-98 Uplift Test By Hurricane Test Laboratory, LLC (FBC Organization #TST ID: 1527) Report #: 0232-0801-00, Report Date: 9/8/00, Report 0232-0910-05, Report Date: 11/18/05, 2. UL580-06 & UL 1897-12 Uplift Test By Intertek/Architectural Testing, Inc (FBC Organization #TST ID: 1527) Report #: H3985.01-450-44 RO, 3. Quality Assurance By Keystone Certifications, Inc. (QUA ID: 1824) Millennium Metals Licensee # 423 4. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering FBC Organization # ANE 1916) 5. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering FBC Organization # ANE 1916) FL #: FL 5211.1-R7 Date: 10/16/17 Report No.: 17-196-5V-S6W-ER Page 6 of 8 Speclaftj Structural Encgineering CBUCK, Inc. Certificate of Authorization #8064 Installation Method Millennium Metals 5V Crimp" & "Millennium-V" Roof Panel Attached to Wood Deck Profile Drawings 24'Cojerage 7116' —12, 7 W-Crimp" Typical Panel Profile View (NotToScale) TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: METHOD 3: METHOD 4: Design Pressure: 112.5 PSF 113.75 PSF 45 PSF 93.75 PSF Deck Thickness: 19/32" 15/32" 15/32- 15/32" Fastener Size: 9 Min. 9 Min. 10 Min. 10 Min. Row Spacing: 12" 1211 24" 12" Fastener Spacing: 12" 61' 1211 12" Fastener Location: Corrugation Peaks Corrugation Peaks between ribs Corrugation Peaks Corrugation Peaks Refer to Drawing#: A-1&A-2 B-1 & B-2 A-1 & A-2 A-1 & A-2 Allowable design pressure for allowable stress design (ASD) with a margin of safety of 2 to 1. FIL #: FIL 5211.1-117 Date: 10/16/17 Report No.: 17-196-5V-S6W-ER Page 7 of 8 Spen--k9ftj Structureil r=nqjlnL=E*rInq CBUCK, Inc. Certificate of Authorization #8064 Installation Method Millennium Metals 5V Crimp" & "Millennium-V" Roof Panel Attached to Wood Deck so7q6 12' 01 Fastener S)adnq AaDw Panel Width Hex4-iead SaewWth VON 3116'ryin. pereb-aton tw deck Refer to Table "A'fbr Fastaw Size Row Spacing Drawing A-1 Typical Assembly Profile View (Not To Scale) Attachment METHOD 1, METHOD 3 & METHOD 4 Per Table "A) r-C1bLt`1 XPI Z, - a Flex -Head Saem wrdi MIN Millenniurn-V'Roof Pand Wth 3t16'Mn. PenI tm Deck Refer to Table "A'fbr Fastener SLze 12' o.a SUPPI ,— lnsLdafion: CDX Flywood Deck or (Opfional) 3'mix. or 25 psi rnin. V\bod Park Refer to Table "A'f6r Mninun Thiclom Drawing A-2 Typical Assembly Isometric View (Not To Scale) Attachment METHOD 1, METHOD 3 & METHOD 4 Per Table "A") NO MUNIN": , III w I FIL #: FL 5211.1-117 Date: 10/16/17 Report No.: 17-196-5V-S6W-ER Page 8 of 8 SpLocIalftj Struc=turcsl E:nc)InL=L=rlricj CBUCK, Inc. Certificate of Authorization #8064 Installation Method Millennium Metals 5V Crimp" & "Millennium-V" Roof Panel Attached to Wood Deck 4fq) kc 6'o.r- Tyocal- , -6'o.c TypicEd , 6'o.c Typical 6'o.c HED(4-iead ScrewWth MAN 3(16'Mn. peneftabon ftu dKk Refer to Table "A'fbr Fastener Size Row -Spadng Drawing B-1 Typical Assembly Profile View (Not To Scale) Attachment METHOD 2 Per Table "A") F-COMN KA a - Fiax Head Saem Wth VOW Wth 3/16'Mn. RenetralJon thni Deck Refer to Table "A'for Fagener Sim ja ja ja ja 6'aa Tvikal I f/ ja SLpport CDX PlywW DacK or Mod plank Refer to Table "A'for Mninun ThdTiess ja Insuldon: Opfional) 3'rroc or 25 psi rrin. Mllenniurn-V'RDd Panel Drawing B-2 Typical Assembly Isometric View (Not To Scale) Attachment METHOD 2 Per Table "A")