Loading...
HomeMy WebLinkAbout217 Towne Center Cir 95-2151; (a) INTERIOR REMODELZONE CONTRACTOR DATE ' i n OUS%m Con s ADDRESS Jr L2 0 y- I U L12 ei c PHONE # 3(,'5` LOCATIOP OWNER ADDRESS PHONE # 4LUMBING CONTRACTOR ADDRESS PHONE # u C` '1, gLECTRICAL CONTRACTOR c ADDRESS PHONE # MECHANICAL CONTRACTOR ADDRESS PHONE # MISCELLANEOUS CONTRACTOR ADDRESS SEPTIC TANK PERMIT NO. SOIL TEST REQUIREMENTS (__) FINISHED FLOOR ELEVATION REQUIREMENTS (__) ARCHITECTURAL APPROVAL DATE: PERMIT #- J O B. -tom ClY' l_. Lyn (11 . COST $ SUBDIVISION: Q LOT NO. BLOCK: SECTION: SQUARE FEET: ) c) () C FEE $ S' U MODEL: STATE NO. FEE $ FEE FEE $ OCCUPANCY CLASS: c-'' INSPECTIONS TYPE DATE OK REJECT BY FEE 4 ENERGY SECT. EPI: 4111 j ,4 j2 6( l5quin l/Jcmd " Wo1,l iskl- Q,x'_ 2 L CERTIFICATE OF OCCUPANCY ISSUED # I DATE: FINAL DATE '3-o CITY OF SANFORD, FLORIDA PPLIC WN, FORBU DING PERMIT C PERMIT ADDRESS P J Total Contract PP of J Describe Work I", Type of Construction Number of Stories Occupancy: Residential LEGAL DESCRIPTION TAX I.D. NUMBER OWNER ADDRESS CITY TITLE HOLDER (IF OTHER THAN OWNER) ADDRESS CITY BONDING COMPANY ADDRESS CITY ARCHI ADDRE CITY MORTGAGE LENDER ADDRESS CITY PERMIT NUMBER Number of Dwellings -' Zoning Commercial Industrial lease attach printout from Seminole County) STATE STATE STATE ONE NUMBER LU`5a—AO ZIP ZIP ZIP CONTRACTOR ECA S 70-,%, csx-47: PHONE NUMBER Y` ADDRESS - 6 Or-, % C ST. LICENSE NUMBER CITY STATE ZIP7G Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL, PLUMBING, MECHANICAL, SIGNS, POOLS, ETC. OWNER' S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating Construction and zoning. A COPY OF THE RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL BE POSTED ON THE JOB SITE WITH PERMITS NO LATER THAN SEVEN (7) DAYS AFTER THE PERMIT HAS BEEN ISSUED. FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR THE IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. ACCEPTANCE OF PERMIT IS VERIFICATION THAT I WILL NOTIFY THE OWNER OF THE PROPERTY OF THE REQUIREMENTS OF FLORIDA LIEN LAW, FS713. H ro Z a w 3 0 Z C] H H UI H 44 GOi O ro m a) 0 1 CL o a) >1 Z a F Signa ture of OwnUr/Agent'& r- " A-1i Type or P/ 't Owner en S nature f otary- Da SHERRY D. DUTIE h' 1't k MM:311i*;i rXP 9FS September 20, 1997 to ignatur of Si Print C 10 n m m ft a FY actor & Date O o H I-' Z t . ctor's Name d C a:.:.( Of f mAy MUSE I r+ NOTARY IaIJ5l I0, 'TATE OF FLORIDA PviY camMISSION # CC132860 EXPIRES: August 4,1995 Application Approv BY:. Date: S` Q FEES: Building .o Radon Police Fire Open Space Road Impact Application 3j PERMITVALIDATION: CHECK CASH DATE '4S---- BY x ORIGINAL ( BUILDING) YELLOW (CUSTOMER) PINK (COUNTY TAX OFFICE) GOLD (CO. ADMIN) THIS APPLICATION USED FOR WORK VALUED. $2500.00 OR MORE T.. DEVELOPMENT FEE WORKSHEET CITY OF SANFORD UTILITY - ADMIN. P. O. BOX 1788 SANFORD, FL 32772-1788 Prol ect Name: 7zl %/{v GH7S / Date: Owner/Contact Person: Phone: Address: `7 Tow^r! c6-7d1Z Type of Development: 1) RESIDENTIAL Type of Units (single family or multi -family): Total Number of Units: Type of Utility Connection individual connections or central water meter & common sewer tap): Water Meter Size (3/4", 1", 2", etc.): REMARKS: 2) NON-RESIDENTIAL Type of Units (commercial, industrial, etc.): Total Number of Buildings: Number of Fixture Units each building): Type of Utility Connection individual connections or central water meter & common sewer tap): Water Meter Size (3/4" 1", 2", etc.) REMARKS: S H.4A //iP9C-7 CONNECTION FEE CALCULATION: REVISED 8/12/92 Cohh , 3 l Sew, 60 LNr y CVg7eA PIA9C7 F = 1ye1' 3 A. f Y 1) Water System Impact Fees Equivalent Residential Connection (ERC) - 300 Gallons Per Day (GPD) Residential - 650/Unit - Single family structure, or multi -family unit containing three (3) bedrooms or more. 467.50/Unit - Multi -family unit Mobileor Home unit containinglessthanthree (3) bedrooms. Type of Fixture Or Group Of Fixtures Fixture Unit Value This category is based on judgement/assumption, estimation that such family units on average require 751 - 225 GPD Automatic clothes washer (2" standpipe) 3 of the water and sewer service of an average via 71 Bathroom group consisting of a water closet, lavatory single family unit.) bathtub or shower stall: Tank water closet 61 Commercial - Flush valve water closet 8 650/ERU - Fixture unit schedule from Southern Plumbing Code 7 r So Bathtub (with or without overhead shower) 2Bidetwillbeused. One ERU will be charged for 3 connection and up to twenty (2) fixture units. t/ Combination sink -and -tray w/food waste grinder 4 For projects having more than twenty (20) fixture I 7`) Combination sink -and -tray w/One 1-1/2" trap 3unitstheImpactFeewillbedeterminedbyincrements258Combinationsink -and -tray w/separate 1-1/2" trap 3ofbasedonmultiplesoffive (5) fixture units above the twenty (20) fixture unit Dental unit or Cuspidor 1 base for the first ERU. (Example: twenty-five Dental Lavatory 1 25) fixture units will be rated as 1.25 eru; a Drinking fountain 1/2 twenty-six (26) fixture units will be rated as 1.5 Dishwasher, domestic 2ERU.) Floor drains w/2" waste 3k 3 2) Sewer System Impact Fees Kitchen sink, domestic w/one 1-1/2" trap 2 Kitchen sink, w/food waste grinder 3. Equivalent Residential Connections 270 Gallons Per Day (GPD) Kitchen sink, w/food waste grinder & dishwasher 1-1/2" trap 5 Residential - Kitchen sink, domestic w/dishwasher 1-1/2" trap 4 1700 Unit - Single family structure, or multi -family unit Lavatory w/1-1/4" waste 1 containing three (3) bedrooms or more. w/1-1/2" waste 2), Z 1275/Unit - Multi -family unit or Mobile Home unit containing Laundry tray (1 or 2 compartments) 2 less than three (3) bedrooms. (This category is Shower stall, domestic S 2basedonjudgement/assumption/estimation that such Showers (group) per head 3familyunitsonaveragerequire75% of water and sewer service of Sinks: Surgeons 3anaveragesinglefamilyunit.) Flushingrim (with valve) 8Commercial - Industrial - Institutional Service (trap standard) 31700/ERU - Fixture unit schedule from Southern Plumbing Code Service (P trap) 2willbeused. One ERU will be charged for connection and up to twenty (20) fixture Pot, scullery, etc. 4 units. For projects having more than twenty (20) fixture Urinal, pedestal, syphon jet blowout 8 units the Impact Fee will be increments of 258 Urinal, wall lip 4 based on multiples of five (5) fixture units above Urinal, stall, washout 4 the twenty (20) fixture unit base for the first Urinal trough (each 6' section) 2ERU. (Example: twenty-five (25) fixture units will be rated as 1.25 ERU; twenty-six Wash sink (circular or multiple) each set of faucets 226) fixture units will be rated as 1.5 ERU. ) Water closet, private ( tank operation) 4 3. Water Meter Connection Fees Water closet, public (valve operation) 8Nr! Fixtures not listed above: Trap size 1-1/4" Or less 1 t WATER METER SIZE Trap size 1-1/2" 2 3/4" $EE130. Trap size 2" 3 210. Trap size 1-1/2" 41. 1-1/2- 400. Trap size 3" 5 soo. 3" Trap size 4" 6 2,900. or they install4" Reference: Standard Plumbing Code, Table 1304.1 page 13-4 and4,400. or they instal6" 7,520. or they install Table 1304.2 page 13-5. 4. Sewer Connection Fee Standard 4" Residential Connection - $260. Non-standard connection - TO BE DETERMINED NOTE: ANY WATER OR SEWER TAP WORK THAT REQUIRES ANY STREET CUT ORTUNNELINGOFTHEPAVEMENTWILLBEANADDITIONAL $250 FOR EACH SUCH TAP. CITY OF SANFORD FIREDEPARTMENT FEES FOR SERVICES PHONE #: 407-322-4952 DATE: BUSINESS NAME: ADDRESS:' Z r PHONE NUMBER:( ) PERMIT #: PLANS REVIEW TENT PERMIT BURN PERMIT REINSPECTION TANK PERMIT FIRE SYSTEM AMOUNT $ COMMENTS: r.% 7— % S-r,- Fees must be paid to Sanford Building Department, 300 N. Park Avenue, Sanford, Florida. Phone # 330-5656. Proof of payment must be made to Sanford Fire Prevention before any further services can take place. I certify that the above information is true and correct and that I will comply with all applicable ll codes and ordinances of the aApp of Sanford, 'da. Sanford ire Preventioni isS' ture 1/ r ETAIL PERMIT SERVICES SA National Permit Service Company TRANSMITTAL RE: Afterthoughts - Seminole Town Center - Sanford, FL TO: Fire Marshal Cohen City of Sanford 407-324-0868 FROM: Kent Fahey Retail Permit Services. 800-556-8.641 DATE: June 30, 1995 PAGES: 3 Sets/Info Sheet METHOD SENT: Federal Express PER YOUR REQUEST XX} FOR YOUR APPROVAL XX} FOR YOUR INFORMATION XX) FOR YOUR FILES COMMENTS: Fire Marshal Cohen, per our conversation, please review these plans. Upon your approval, please submit to the City of Sanford Building Department for their review. Should you have any questions or require further information, please don't hesitate to call. I appreciate your help. Thank you. Sincerely, 22530 Townhall Court 0 Katy, Texas 77449 • Tel:(713) 347-2323 0 Fax:(713) 347-4060 lam, TENANT IMPROVEMENT tenant lay-out/build-out, interior remodel/finish) Project Afterthoughts Seminole Town Center 183 Oregon Ave. Space #P-3 Sanford, FL 32771 Owner: Woolworth Corporation 233Broadway, 6th Floor New York, NY 10279 212- 553-2128 Tom Manwarren Contractor: OUT TO BID G. C. will pick up and''pay for Building Permit at a later date. Contractor will have all necessary licences. We are to submit or walk through plans, so permit will be ready when project is awarded. Use Group: Mercantile Construction Type: 2-C (1 Hr) Occupant Load 33 Subdivision: Seminole T.C. Size: 1,079 Sq. Ft. Value: $ 30,000 No. of Employees: 3-4 Start date: July 15, 1995 Scope of work: INTERIOR ALTERATION (existing retail lease space Applicant: Retail Permit Services 22530 Townhail Court Katy, Texas 77449 800- 556-8641 Kent Fahey Architect: Prizm Architects 1333 Corporate Drive Irving, TX 75038 214- 71.4-0420 James Hamill BP 101 IO2 C7TY. OF 5ANFORD 9/ 12/95 Land Master 50ecti on By Street Address 14 :27 : 24 Type ooti ons . -press Enter. 1= Select 5=View detail Opt Street address Owner 214 TOWNE CENTER CR$1/87.50 8)22 ii:2563 FRIEDMANS JEWELERS 15 --._-... TOWNE CENTER CR_ ___ _... SEM-Y-NOL.E. J_OWNE CENTE 21. 7-- __.. _ _ C_ENTER_CR/87.ra 7/31fgs-A2S2ft_AFTER_THOUGHYS_..___,_ 219 TOWNE TOWNE CENTER CR$3zs 7/7 9s-tt 2486, EVERYTHING BUT WATER 220 TOWNE CENTER CRiV87.so /i9NS74&24.S7 K--JEWLERS 222 G, 223 l TOWNE TOWNE CENTER CENTER CR9487. Sb 8//(/qs-t# 2ssr9 CRis2oa s/3o/9s-It- 2339 AND COMPANY RUBY TUESDAY.S 224 TOWNE CENTER CRtd97.S'6 5/3t j9sv 23LIo BENTLY . LUGGAGE 225 TOWNE CENTER CR 226 TOWNE CENTER CR%79G.2S Gfz-iJ95-*+246-6 FOOTLOCKER 228 TOWNE CENTER CR.4Q7S 7/zj/95dr ZSo9 BROOKSTONE 229 TOWNE CENTER CR$&So 8/9/qstt- -,-55o SWEET FACTORY 231 TOWNE CENTER CR1427,50 5-7-9 232 TOWNE CENTER CR NONE DUE SUNGLASS ,HUT 234 TOWNE CENTER CR4Co1;;o 17f s/4S.ft 2SZ1 SEMINOLE TOWNE CENTE G> d1/ t.t. Cooks e, aeip F3= Exit F 12=Cance'I 07- 04 SA MW KS IM II S1 A0 KB SP101IO2 CITY OF SANFORD 9/12/95 Land Master- Selection By Street Address 14:27:52 Type options, press Enter. 1= Select 5=View detail Opt Street address Owner, 235 TOWNE CENTER CRPI.51.50 61m51* 23so LIMITED TOO 236 TOWNE CENTER CR 41'3op 8/9f4stt 25 s THE GREAT STEAK & PO 23£ TOWNE CENTER CRI14ioz-So 7/Zo/g5#42507 SARK.U/JAPAN 239 TOWNE CENTER CR LIMITED EXPRESS 240 TOWNE CENTER CRI697S 2s4G FLAMERS CHARBOILED H 242 TOWNE CENTER CRC/-787,15'0 T131W%At 2S33 NATURES TABLE 243 TOWNE CENTER CR$Z27s 6/8/9sfr z35/7 EXPRESS BATH/BODY 244 TOWNE CENTER CRA-?-` CAJUN CAFE 245 246 TOWNE TOWNE CENTER CENTER CR. CRC 32S 7 45 2 F8S c' Iu1TWnL F. F+ 19-4 GT E DIAMOND J LM' S 247 TOWNE CENTER CR 248 TOWNS CENTER CRI1300 8131i9s1ZS73 SBARRO 249 TOWNE CENTER CR lvbvf nu4 GEMiNftE TOWNE el,IqT FA r c 250 TOWNECENTERCRi/e 62.So PANDA EXPRESS 251 TOWNE CENTER CR S + F3=Exit F12=Cancel 07-04 5A MW KS I I S1 A0 K$ r FROM THE CITY BUILDING OFFICTAL September 12, 1995fh TO: All Concerned Departments FROM: Gary Winn, Building Officials SUBJECT: Issuance of Certificate of Occupancy for the Build Out of Interior of Mall and Interior Local Stores The undersigned have agreed to approve the issuance of the Certificate of Occupancy for all interior local stores and the Mall area itself. Engineering Zoning Public Work! Utilities. _ GW/ar CH,-Cft ow '-"E1 P/9yrcKy FROM'KONICA FAX TO: 407 365 8538 JUL 27, 1989 211^AM P.0i NORTHEASTERN REGIONAL OFFICE Rlihl luf!TC1u CCIJTCII . l+Ctfl DUIILIUQTnIJ . SIT. I IL1LLu florLIB . UMILINUTON, Nj W545 _ 1MO1 bft-8556 6 { r { 2 h YS .nF ks, September 12, 1995 d i k M1 f x To whom it may concern; Ahe -Thoughts is requesting a T'CO (Temporary Cefdfl tale Of Opel'auun} filial. We will x not sell merchandise or conduct business until Seminole Town Canter receives the TCO or until the center is ready to open. A hard copy of this letter will be sent to the following address: City of Sanford Building Department 300 N. Park Avenue Sanford, FL 32771 Sincerely, Marcia Deputy t Regional Coordinator, t; AfterThoughts/Carimar f- J yFE} 4 43A' To Fire Marshal of Sanford: I Terry S. Maze request it0ection of space VC-9 in theSerninole Town 0 T attheaboveaddressforin order to stock and train my employees. I will not open the store u till the Seminole Town Center Mail has it's Co.; Sincerely, Terry S. Maze President Mail rot CITY OFF SANFORD FLRE.DEPARTMENT FEES FOR SERVICES PHONE #: 407-322-4952 qr- DATE: 0 / PERMIT #: J VU—/ BUSINESS NAME: T%ic> /, jS ADDRESS•. I-) PHONE NUMBER:( ) PLANS REVIEW TENT PERMIT BURN PERMIT REINSPECTION TANK PERMIT FIRE SYSTEM AMOUNT $ C 0 !q;k COMMENTS: /117 Q,(% T 4=2 min 16 Ae 3 Fees must be paid to Sanford Building Department, 300 N. Park Avenue, Sanford, Florida. Phone # 330-5656. Proof of payment must be made to Sanford Fire Prevention before any further services can take place. I certify that the above information is true and correct and that I will comply with all applicable codes and ordinances of the ity of Sanford, Florida. Sanford" Frre'Preventiot /V A1)plicaht-9'Si4fiatu CITY OF SANFORD, FLORIDA PERMIT NO. DATE — THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO INSTALL THE FOL- LOWING ELECTRICAL WORK: OWNER'S NAME /'I C t c ` l apt ADDRESS OF JOB 7Ow n t Cent"', C T Ser",Je n ire CtAttr ELEC. CONTR. QJ LOW 4 cC f`iC Residential Non-residentialx E Subject to rules and regulations of the city and, national electric codes. Number AMOUNT s Alteration Addition Re air Chan e of Service Re _ ommercial h Mobile Home i I Factory Built Housing New Residential 0-100 Amp Service 101-200 Amp Service 201 Amp and above New Commercial go Amp Service 0 Application Fee TOTAL By signing this application I am stating I will be in compliance with the NE inc ing Article 110. Section 110-9 nd 110-10 Building Official Master Electricia C-c- 0000a $v STATE COMPETENCY NO. CITY OF SANFORD, FLORIDA PERMIT NO. DATE THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO INSTALL THE FOLLOWING H.A.R.V. MECHANICAL EQUIPMENT: OWNER'SNAME ADDRESS OF JOB t-c%vx) 6( ! < LJr MECHANICAL CONTR. RESIDENTIAL COMMERCIAL Subject to rules and regulations of Sanford mechanical code. NATURE OF WORK Master Mechanical COMPETENCY CARD NO. GjCCITY OF SA/NFORD, FLORIDA PERMIT NO I J ' D J DATE _ s THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO INSTALL THE FOL- LOWING PLUMBING WOR OWNER'S NAME ADDRESS OF JOB`"'- -- PLUMBING CONTR e0vv. Res. _ Comm. Subject to rules and regulations of Sanford plumbing code. Residential: I Number Alteration, Addition, Repair I Amount New Residential: One Water Closet Additional Water Closet Commercial: Fixtures. Floor Drain, Trap 14 Sewer r I Water Piping_ Gas Piping Factory -built housing Mobile Home Application Fee Minimum Commercial Permit: S25. oo A Total Master Plumber COMPETENCY CARD NO. APPLICATION FORsxBUILDING PERMIT CITY OFt`SANFORD, FLORIDA DATE 71)L,5/)b To the Building Official: PERMIT NO. y3 ` l The undersigned hereby applies for a permit for the following described work: OWNER ADDRES NATURE OF WORK S(Q S I (ice L OX4 LEGAL DESCRIPTION APPLICANT'S NAME N f APPLICANT'S ADDRESS APPLICANT'S PHONE NUMBER i VALUATION 1 FEE FAILURE TO COMPLY WITH THE MECHANICS' LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS I certify that the above infor- mation is true and correct and that I will comply with all applicable cod and ordinances of the CiAafijord, FL. Building icial ttt Signature FROM LETTERS INTERNATIONAL CORPORATION SEP.14.1995 11:07 AM P 2 09/14/95 10:20 V317 685 7222 SIMON PROPERTY G (QO1/001 MS k w"11,v1,'N1 Jim Felton April 10,1995 KgNNSY SHOE CORPORATION Via DU L. 213 Broadway 3642076 Now York, NY 10279-0099 6541395192 Reference: SIGN REVIEW AFTERTHOUGHTS $EHINOLe TOWNE CENTER SPACE #115-3 8ANFoRD, l+L Dear Mr. Felton: Yov sign design and construction drawings have been reviewed, and they arc approved as noted One set of plans marked with review comments is enclosed for your records. You are responsible for informing your vendor of pertinent Jesse requirements, procedures for chsoking in w;th the appropriate, 1,andlord Repmentatives at the site, and all Mall Rules and Regulations, Sincerely, Direct Dial (317) 263.7916RobertL11orkay Tenant Coordinator Copy: Mail Manager, Central piles MS/AFrsR9A1.362S MERCHANTS 1'Ln2'A r'-)ST ornr.E Bc)x 7033 INDIANAPOLIS, INDIANA 46207 317.636-1600 R i a 1 Ski 5-1 h PR-1 u&wmou L.. .. ...-.:•,..-: 1=,.- t', Srr- • 4ar+:. ._.. _ ter..._, _ _ ._. _ - 1H- \ iifi +f1 'i. _ Y _ LA irk •R• w•+r r'. 'dam :!: f ; 'i . YF IP l(F h _ VA Ho C `*RE .. 7 ' - _ 0ii-I idEt11'RAL BIER inGt f Typ) fD . . 1'7—l/U 5V 3'&-13 i 10+ CfE+NG 3'1—'3116' C 19 2"-4 LEASE • 1J1£ 70: SASE • Ul ' Clt , kfiLii-T, E.EI'IDN 1h TEROP STDFEF->C c _ 12YA1 C, i A f; SJEI f' . •S' B r7t 44 f LEX WB)tT 6FfE0rnlu F EAITIIJ. ,' METAL ca\cmt AW7 ae R.MPANTED— TdN,I 1031 RA P tC ENAMEL. l SIGH FACfDdAT-Akt IR:NrsuRPA:E U.L.:i£C H0D WH TRANSU MIT COPAPONK 1W 190C GEIEMAR91.1 WK Soec. r !• ia.nnarf .mn i. cp i. ,,4.8035 4, ALi1 1A.&Ijtl BAR•FASTE14ED ABOVE CEiuNG l NOTE SPACING MUST BE f EQUAL, ON BOTH ENDS 28" TRMCAf I U MtATEDC iXNNELL.ETTERS PAINITDTO HUNG FROM CEILING WITH I E)LA. MATCH FETURNS ALUMI(y,L M _C.QI.vWil - COVERED WITH T DIA. CHROME SLEEMNG. DATE ME t SAT-N tts BER Ar 1a' SSEET NUPS ER: —, oP,AYN a. CHECKED BY: APRi'ti}_ z'"' APP. DATE, a LAU Rf VAS1 Ns APP— EEy, FROM : LETTERS INTERNRTIONRL CORPORATION SEP.13.1995 12:06 PM P 5 m Ml i fir/rr///// rr irririir i rrrr rr 1•• j 9 NORTHEASTERN REGIONAL OFFICE4*4ip BURLINGTON CENTER • 2501 BURLINGTON - MT. HOLLY ROAD • BURLINGTON, NJ 08016 • (609) 239-8388 September 12, 1995 O To whom it may concern: AfterThoughts is requesting a TCO (Temporary Certificate of Operation) final. We will not sell merchandise or conduct business until Seminole Town Center receives the TCO or until the center is ready to open. A hard copy of this letter will be sent to the following address: City of Sanford Building Department 300 N. Park Avenue Sanford, FL 32771 Sincerely, Marcia Deputy Regional Coordinator, AfterThoughts/Carimar APPLICATION. FQR,BUILDING PERMIT CITY OF SANFt7RD, i 3R'IDA ageDATE (5 PERMIT NO. To the Building Official.: The undersigned hereby applies for a permit for the following described work: "'A, RCZ, TA006A P-3 OWNER .JI//1 C -I o(A)AIC [ '..Lsi"Y OU t p ADDRESS NATURE OF WORK LIt1'f/4 S/oXg/ 4/617 5 / LEGAL DESCRIPTION APPLICANT'S NAME 5'nfGrf APPLICANT'S ADDRESS 719 &--sydla^rf 12z b:w&&,-y2 APPLICANT'S PHONE NUMBER VALUATIONlJ j FEE FAILURE TO COMPLY WITH THE MECHANICS' LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS I certify that the above infor= mation is true and correct and that I will comply with all applicable codes and ordinances. of the City of Sanford, FL. uildin Official Applicant's Signature State No. 609- / 7000/,9j` L._ - Hydraulics Summary Sheet SOUTHEAST FIRE SPRINKLERS, INC. Designer: DAVID HUYSMAN III 799 BENNETT DRIVE Calc By: DAVID HUYSMAN III LONGWOOD, FLORIDA 32750 Date: 8-14-95 Project Information AFTERTHOUGHTS SPACE #P-3 SEMINOLE TOWNE CENTER SANFORD, FL Contract No: 65102 Building: SEMINOLE TOWNE CENTER System ID: @NS7000 Ref Drawing: FP1 Const: STEEL -NON COMBUSTIBLE Occupancy: MERCANTILE Authority: CITY OF SANFORD 1--------------------------------------------I System Information Hydraulics Design Criteria Standard: NFPA 13 Hazard: ORDINARY HAZARD Figure: 5-2.3 Curve: 3 System Type: WET Density: .20 GPM/SgFt Remote Area: 1079 SgFt Spr Cov= 130 SgFt Sprinklers & Nozzles Manufac: CENTRAL Model: MODEL "GB" Size: 1/2 K-Factor: 5.6 Temp Rating: 155 Hydraulics Information Demand... Sprinkler Required Pres: 52.40 PSI Required Flow: 317.97 GPM Static Elev: 0.00 Ft System Total Pres: 52.40 PSI Add'l Flows: 0.00 GPM Hose at Srce: 250.00 GPM Total Flow: 567.97 GPM Supply... Water Flow Test Static: 60.00 PSI Residual: 49.00 PSI Oty Flowing: 1511.00 GPM FT Elevation: 0.00 Ft Date: Time: By. Pump Data Rated 0.0 PSI@ 0.0 GPM Boost Pres ( NA?) PSI Discharge Pres (NA) PSI Discharge Flow (NA) GPM Combined Static: (NA) PSI Residual: (NA) PSI Flow: (NA) GPM Available... P) 58.20 PSI@ 567.97 GPM F) 52.40 PSI@ 1237.16 GPM Margin... Pressure: 5.80 PSI Flow: 669.19 GPM Sigma Dynamics Corporation 7700 Hydraulics SUBMITTAL SERIAL N0:2968HY1 Afterthoughts Elfrink Construction FLOW TEST RESULTS Water Supply STATIC 60.00 PSI RESIDUAL 49.00 PSI @ 1511.00 GPM CITY PRESSURE AVAILABLE AT 568.0 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 200 25.70 18.20 5.60 21.06 201 23.72 19.60 5.60 17.94 202 19.60 19.60 5.60 12.25 203 18.89 15.00 5.60 11.38 204 26.24 17.60 5.60 21.95 205 25.43 17.00 5.60 20.63 206 23.47 18.20 5.60 17.57 207 19.39 18.20 5.60 11.99 208 18.69 15.00 5.60 11.13 209 26.11 17.00 5.60 21.74 210 24.10 18.20 5.60 18.52 211 19.92 18.20 5.60 12.65 212 19.20 15.00 5.60 11.76 213 27.51 15.00 5.60 24.13 TOTAL WATER REQUIRED FOR SYSTEM OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 4 TO 5 58.20 PSI 317.97 GPM 250,00 GPM 567.97 GPM 52.40 PSI 0.00 PSI 30.40 FPS OS-15=1995 PAGE`1 SUBMITTAL SERIAL NO:2968HY1 08-15-1995 PAGE 2 Afterthoughts Location flow Pipe fittings Equiv Friction Pressure in Size Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 102 202 1.049 L 3.00 C=120 PT 12.25 202) Q 19.60 F=T F 5.00 PE 1.30 DR T 8.00 0.1254 PF 1.00 PT 11.95 102 ) 113 213 1.049 L 3.00 C=120 PT 24.13 213) Q 27.51 F=T F 5.00 PE 1.30 DR T 8.00 0.2347 PF 1.88 12 113 1.049 L 5.00 C=120 PT 24.71 113) Q 27.51 F=T F 5.00 PE 0.00 BN T 10.00 0.2347 PF 2.35 PT 27.06 12 ) 112 212 1.049 L 3.00 C=120 PT 11.76 212) Q 19.20 F=T F 5.00 PE 1.30 DR T 8.00 0.1207 PF 0.97 111 112 1.049 L 8.00 C=120 PT 11.43 112 ) Q 19.20 F=0 F 0.00 PE 0.00 BN T 8.00 0.1207 PF 0.97 PT 12.40 111) 111 211 1.049 L 3.00 C=120 PT 12.65 211 ) Q 19.92 F=T F 5.00 PE 1.30 DR T 8.00 0.1292 PF 1.03 110 111DQ 19.20 1.049 L 14.00 C=120 PT 12.38 111) Q 39.12 F=O F 0.00 PE 0.00 BN T 14.00 0.4503 PF 6.30 PT 18.68 110 ) 110 210 1.049 L 3.00 C=120 PT 18.52 210) Q 24.10 F=T F 5.00 PE 1.30 DR T 8.00 0.1838 PF 1.47 109 110DQ 39.12 1.380 L 12.00 C=120 PT 18.69 110 ) Q 63.22 F=C F 0.00 PE 0.00 BN T 12.00 0.2878 PF 3.45 PT 22.14 109 ) 109 209 1.049 L 3.00 C=120 PT 21.74 209) Q 26.11 F=T F 5.00 PE 1.30 DR T 8.00 0.2131 PF 1.70 12 109DQ 63.22 1.380 L 3.00 C=120 PT 22.14 109 ) Q 89.33 F=T F 6.00 PE 0.00 BN T 9.00 0.5455 PF 4.91 SUBMITTAL SERIAL N0:2968HY1 08-15-1995 PAGE 3 Afterthoughts Location Flow Pipe Fittings Equiv Friction Pressure in Size Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 5 12DO 27 .51 2.067 L 4.00 C=120 PT 27.05 12 ) Q 116.84 F=0 F 0.00 PE 0.00 NC T 4.00 0.1253 PF 0.50 PT 27 .55 5 ) 108 208 1.049 L 3.00 C=120 PT 11.13 208 ) Q 18.69 F=T F 5.00 PE 1.30 DR T 8.00 0.1148 PF 0.92 107 108 1.049 L 8.00 C=120 PT 10.75 108) Q 18.69 F=0 F 0.00 PE 0.00 BN T 8.00 0.1148 PF 0.92 PT 11.67 107 ) 107 207 1.049 L 3.00 C=120 PT 11.99 207) Q 19.39 F=T F 5.00 PE 1.30 DR T 8.00 0.1229 PF 0.98 106 107DQ 18.69 1.049 L 14.00 C=120 PT 11.67 107) Q 38.08 F=0 F 0.00 PE 0.00 BN T 14.00 0.4282 PF 5.99 PT 17.66 106 ) 106V 206 1.049 L 3.00 C=120 PT 17.57 206) Q 23.47 F=T F 5.00 PE 1.30 DR T 8.00 0.1750 PF 1.40 105 106DQ 38.08 1.380 L 12.00 C=120 PT 17.67 106) Q 61.55 F=O F 0.00 PE 0.00 BN T 12.00 0.2738 PF 3.29 PT 20.96 105 ) 105 205 1.049 L 3.00 C=120 PT 20.63 205) Q 25.43 F=T F 5.00 PE 1.30 DR T 8.00 0.2030 PF 1.62 11 105DQ 61.55 1.380 L 3.00 C=120 PT 20.95 105) Q 86.98 F=T F 6.00 PE 0.00 BN T 9.00 0.5192 PF 4.67 10 11 2.067 L 7.75 C=120 PT 25.62 11 ) Q 86.98 F=0 F 0.00 PE 0.00 NC T 7.75 0.0726 PF 0.56 PT 26.18 10 ) 104 204 1.049 L 3.00 C=120 PT 21.95 204 ) Q 26.24 F=T F 5.00 PE 1.30 DR T 8.00 0.2150 PF 1.72 SUBMITTAL SERIAL N0.2968HY1 08-15-1995 PAGE 4 Afterthoughts Location Flow Pipe Fittings Equiv Friction Pressure in Size Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 10 104 1.049 L 8.75 C=120 PT 22.37 104) Q 26.24 F=T/2E F 9.00 PE 0.00 BN T 17.75 0.2150 PF 3.82 PT 26.19 10 ) 103 203 1.049 L 3.00 C=120 PT 11.38 203) Q 18.89 F=T F 5.00 PE 1.30 DR T 8.00 0.1171 PF 0.94 102 103 1.049 L 8.00 C=120 PT 11.02 103) Q 18.89 F=0 F 0.00 PE 0.00 BN T 8.00 0.1171 PF 0.94 101 102DQ 19.60 1.049 L 14.00 C=120 PT 11.96 102 ) Q 38.49 F=0 F 0.00 PE 0.00 BN T 14.00 0.4369 PF 6.12 PT 18.08 101) 101 201 1.049 L 3.00 C=120 PT 17.94 201) Q 23.72 F=T F 5.00 PE 1.30 DR T 8.00 0.1784 PF 1.43 100 101DQ 38.49 1.380 L 12.00 C=120 PT 18.07 101) 0 62.21 F=0 F 0.00 PE 0.00 BN T 12.00 0.2793 PF 3.35 PT 21.42 100) 100 200 1.049 L 3.00 C=120 PT 21.06 200) Q 25.70 F=T F 5.00 PE 1.30 DR T 8.00 0.2070 PF 1.66 10 100DQ 62.21 1.380 L 3.00 C=120 PT 21.42 100) Q 87.91 F=T F 6.00 PE 0.00 BN T 9.00 0.5296 PF 4.77 5 100Q 113.22 2.067 L 4.00 C=120 PT 26.19 10 ) Q 201.13 F=0 F 0.00 PE 0.00 NC T 4.00 0.3423 PF 1.37 4 5DQ 116.84 2.067 L 2.50 C=120 PT 27.56 5) Q 317.97 F=0/T F 10.00 PE 0.00 FM4 T 12.50 0.7987 PF 9.98 3 4 4.260 L 120.00 C=120 PT 37.54 4) Q 317.97 F=0/T F 16.00 PE 0.00 FM3 T 136.00 0.0236 PF 3.21 SUBMITTAL SERIAL N0:296°8HY1 08-15-1995 PAGE 5 Afterthoughts Location Flow Pipe Fittings Equiv Friction Pressure in Size Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 2 3 6.357 L 54.00 C=120 PT 40.75 3) Q 317.97 F=E/T F 35.00 PE 0.00 FM2 T 89.00 0.0034 PF 0.30 1 2 6.357 L 15.00 C=120 PT 41.05 2) Q 317.97 F=BV/E F 20.00 PE 6.50 FR T 35.00 0.0034 PF 0.12 0 1 8.249 L 10.00 C=120 PT 47.67 1) Q 317.97 F=DCA/ALV,T F 33.00 PE 0.00 FM1 T 43.00 0.0009 PF 0.04 8" Febco Mod. 805YD - Double Check Assembly 4.00 8" Central Alarm Valve 0.70 PT 52.41 0 ) 125 120 115 110 105 100 95 90 ti6 80 75 70 a_ 56 60 46 40 36 30 26 20 16 1a 6 a Afterthoughts Sigma Dynamics Corporation 7700 Supply I Demand Graph Margin Pressure S.80 PSI Flow 669.19 GPM 0 o C D 200 400 600 800 1000 1200 1400 Ism 1800 20 System Demand.. Sprinkler Demand 52.40 PSI @ 317.97 GPM Additional Flows 0.00 GPM Hose at Source 250.00 GPM Total Demand S2.40 PSI @ S67.97 GPM Water Flaw (GPM) Water Supply.. Static 60.00 PSI Residual 49.00 PSI 0 1S11.00 GPM Elevation 0.00 PSI r DO M: prinklerG Upright, Pendent and Recessed Pendent Glass Bulb Automatic Sprinkler Manufactured by: Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product Technical Description 91 Data The Central Model GB Upright and Model: GB Pendent and Recessed Pendent Style: Upright, Pendent or Recessed Automatic Sprinklers are standard Pendent (adjustable) spray sprinklers. They incorporate the Escutcheon: Model GB'/2" Recessed latest in heat -responsive, glass bulb Note: For the recessed version, only the technology, which results in a much Model GB'%" Recessed smaller more attractive sprinkler than Escutcheon assembly may be used. Substitution of other those manufactured with a more "recessed" escutcheons may traditional design approach. The impair the operating sensitivity and operating mechanism consists of a distribution pattern and void liquid -filled 5 mm diameter frangible manufacturer's warranty. capsule that is only 1.6 cm in length. Orifice Size: '/2" (12.7mm) The Model GB Automatic Sprinklers K-Factor: 5.6 (80.08) nominal are intended for installation in Thread Size: '/2" (12.7mm) N.P.T. accordance with current NFPA 13 Temp. Rating & Glass Bulb Color: Standards. They are available in 1/2" 135°F/571C Orange orifice size and a variety of 1550F/680C Red temperature ratings, finishes and 1750F/790C Yellow decorative coatings. 200°F/930C Green The Model GB Recessed Glass Bulb 2860F/141°C Blue 360°F/1820C Purple (3600 not F.M. Automatic Sprinkler incorporates a Approved) significant cost saving feature; a 2- Approvals: UL, U.L.C, F.M. piece special escutcheon assembly Meets: MIL-STD-910C, MIL-STD-167-1, that provides for W of field adjustment and MIL-STD-810-C shock, resulting in an easily accomplished vibration, and salt fog tests for tight fit against the ceiling. maritime applications. Maximum Working Pressure: 175 P.S.I. Operation: The glass bulb capsule Factory Hydro Test: 100% at 500 p.s.i. Standard Finishes: operating mechanism contains a heat- Sprinkler: brass or chrome plated sensitive liquid that expands upon Escutcheon: brass or chrome plated application of heat. At the rated Corrosion -Resistant Coatings (U.L. Only): temperature, the frangible capsule white and black painted ruptures thereby releasing the orifice Highest Allowable Ambient Temperature for seal. The sprinkler then discharges Storage of Sprinklers: 1001F/381C water in a pre -designed spray pattern Adjustable Range Below Ceiling: to control or extinguish the fire. 3/4" to 13/8" Length: 2" (31.8 mm) Width: 1 " (25.4 mm) (frame arms) Weight: 2.0 oz. (56.7grams) Pendent For specific listing requirements, see the appropriate 2.5 oz. (70.9 grams) Upright information contained in this brochure. 3.5 oz. (99 grams) Recessed Pendent 2" Orifice 11" Automatic Sprinkler No. 3.6.0 Figure 1 11And al (M I lnrinhf Cnrinlrlor Figure 2 Model GB Pendent Sprinkler t t / 1 FACE OF REDUCING I I COUPLING 1 11/16" Ref. 2 V 1 3/16" Diameter i Figure 3 Model GB Recessed Pendent Sprinkler t1 tt t 2" Minimum Diameter / 1 1 2 1/4" Maximum Diameter j t 1 FACE OF REDUCING 1 I COUPLING SUPPORT CUP j I I I I I Model GB t/ 2" Recesse ` Escutcheon 1 1 MAX. 3/8" MIN. 71, 3/32" FINISHED CEILING LINE 1 3/8" MAX. 3/4" MIN. T 1 13/16" 2 7/8" Diameter 2 Design Requirements — Standard Applications The Model GB Recessed Automatic Sprinklers are intended for area coverages, flow and pressure requirements as specified in current NFPA 13 standards. When installed in the recessed position, the recessed cup escutcheon and sprinkler are listed together as a single unit and must be so utilized. Installation All Central Model GB Upright, Pendent and Recessed Pendent Automatic Sprinklers must be installed according to current NFPA 13 Standards. Deviations from these requirements and standards or any alteration to the sprinkler itself will void any warranty made by Central Sprinkler Company. In addition, installation must also meet local government provisions, codes, and standards as applicable. The system piping must be properly sized to insure the minimum required flow rate at the sprinkler. Check for the proper model, style, orifice size, and temperature rating prior to installation. Install sprinklers after the piping is in place to avoid mechanical damage; replace any damaged units. Wet pipe systems must be protected from freezing. Upon completion of the installation, the system must be tested per recognized standards. In the event of a thread leak, remove the unit, apply new pipe joint compound or tape, and reinstall. Installation Sequence Step 1. The unit must be installed in the upright position for upright style sprinklers, and in the pendent position for pendent style sprinklers. The recessed pendent must be installed with the deflector not less than 3/4" nor more than 1 %" below the ceiling. Step 2. The face of the sprinkler fitting should be installed a nominal to 1" behind the finished ceiling line, as shown in the installation Diagram on page 2. Adjustments may be made via the push -on escutcheon plate to compensate for variations in the fittings. Do not use the push -on escutcheon plate to hold the unit in position. The sprinkler will function properly only when the system piping is anchored to the building structure. Otherwise, reaction force from system initiation could alter the sprinkler alignment and disrupt the spray pattern. Step 3. Use only a non -hardening pipe joint compound or Teflon" tape. Apply to the male threads only. Step 4. Hand tighten the sprinkler into the fitting. For upright sprinklers, use a Central Sprinkler Combination Wrench, for pendent and recessed pendent sprinklers use a Central Sprinkler Universal Wrench, to tighten the unit into the fitting. A leak -tight joint requires only 7 to 14 ft.-Ibs. of torque; a tangential force of 14 to 28 lbs. delivered through a 6" handle will deliver adequate torque. Torque levels over 21 ft.-Ibs. may distort the orifice seal, resulting in leakage. Teflon is a trademark of the DuPont Corp. Combination Wrench (Part #1106) for upright sprinklers) Universal Wrench (Part #1122) (for pendent and recessed pendent sprinklers) Step 5. To install the escutcheon plate, align it with and press it over the sprinkler body until the outer edge of the escutcheon meets the mounting surface. Caution: Special care must be taken when installing pendent sprinklers with a CPVC system. Sprinklers must be installed after the CPVC manufacturer's recommended setting time for the primer and cement to ensure that neither accumulate within the sprinkler. Special care must be taken when installing with a copper system. Sprinklers must be installed only after the inside of the sprinkler nipple and associated fittings have been wire brushed to remove any flux. Residual flux can cause corrosion and in extreme cases can impair proper sprinkler operation. Care & Maintenance Sprinklers must be handled carefully. They must not be transported or stored where ambient temperature may exceed 100°F/380C. For best results, store them in a dry, cool location in the original shipping package. Do not install sprinklers that have been dropped or visibly damaged. Sprinklers must never be painted, coated, plated, or altered in any other way from manufactured condition or they may not function properly. Any sprinklers altered in such manner must be replaced. The owner is responsible for the proper operating condition of all fire protection devices and accessories. The NFPA Standard 25 entitled, Inspection, Testing and Maintenance of Water -Based Fire Protection Systems", contains guidelines and minimum maintenance requirements. Furthermore, the local Authority Having Jurisdiction may have additional regulations and requirements for maintenance, testing, and inspection that must be obeyed. It is recommended that sprinkler systems be inspected regularly by a qualified inspection service. Length of time between such inspections can vary due to accessibility, ambient atmosphere, water supply, and site activity. Do not attempt to reassemble or otherwise reuse a sprinkler that has operated. Replace any sprinkler exhibiting corrosion or damage; always use new sprinklers of the same type and temperature rating as replacements. Because the discharge pattern is critical to protection of life and property, nothing should be hung or attached to the sprinkler unit that would disrupt the pattern. Such obstructions must be removed. In the event that construction has altered 1994 Central Sprinkler Company Printed in U.S.A. the original configuration, additional sprinklers must be installed to maintain the protection level.' Do not attempt to replace sprinklers without first removing the fire protection system from service. Be certain to secure permission from all Authorities Having Jurisdiction, and notify all personnel who may be affected during system shutdown. A fire watch during maintenance periods is a recommended precaution. To remove the system from service mode, first refer to the system operating guide and valve instruction. Drain water and relieve pressure in the pipes. Remove the existing unit and install the replacement, using only the sprinkler wrench. Be certain to match model, style, orifice, and temperature rating. A fire protection system that has been shut off after an activation should be returned to service immediately. Inspect the entire system for damage and replace or repair as necessary. Sprinklers that did not operate but were subjected to corrosive elements of combustion or excessive temperatures should be inspected, and replaced if need be. The Authority Having Jurisdiction will detail minimum replacement requirements and regulations. Guarantee: Central Sprinkler Company will repair and/or replace any products found to be defective in material or workmanship within a period of one year from the date of shipment. Please refer to the current Price List for further details of the warranty. CENTRAL Ordering Information Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, model, style, orifice size, temperature rating, type of finish or coating, and sprinkler wrench. Availability and Service: Central sprinklers, valves, accessories, and other products are available ` throughout the U.S. and Canada, and internationally, through a network of Central Sprinkler distribution centers. You may write directly to Central Sprinkler Company, or call (215) 362- 0700 for the distributor nearest you. Patents: Patents are pending. Conversion Table: 1 inch = 25.400 mm 1 foot = 0.3048 M 1 pound = 0.4536 kg 1 foot pound = 1.36 Nm 1 psi = 6.895 kpa d 0.0689 bar 0.0703 kg/cm2 1 U.S. gallon = 3.785 dm3 3.785 liters Conversions are approximate. Central Sprinkler Company 451 N. Cannon Avenue, Lansdale, PA 19446 Phone (215) 362-0700 FAX (215) 362-5385 GB.4