HomeMy WebLinkAbout166 Kelly Cir 17-1123; WINDOWSCITY OF SANFORD
BUILDING & FIRE PREVENTION
APR 2 4 2017 PERMIT APPLICATION
D
Application No: / 7
Documented Construction Value: $
o"
Job Address: 166 KELLY CIRCLE SANFORD, FL 32773 Historic Distri t: Yes No 1i
Parcel ID: 12-20-30-511-0000-0270 Residential i Commercial
Type of Work: New Addition Al eration Repair Demo Change of Use Move
l ," II ,^,
Description of Work: o (k f km w VY l( u V U % _ [Aa, ,
Plan Review Contact Person: MARISOL MOJICA Title: ASST
Phone: 407-261-2277
Name JAMES R CAWTHON
Fax: 407-261-2277 Email: MARISOLMOJICA@NEWSOUTHWINDOW.COM
Property Owner Information
Phone: 407-844-1882
Street: 166 KELLY CIRCLE Resident of property?
City, State Zip:
SANFORD, FL 32773
Contractor Information
Name Phone:
Street: Samuel Ochstein CRC #1330822 Fax:
NewSouth Window Solutions Inc -
City, State Zl
820 E. Altamonte Dr. Altamonte Springs, FL 32701 - State License No.: p' — Phone: 407-261-2277 - Fax 407-261-2278
marisolmojica@newsouthwindow.com
r Information
Name: Phone:
Street: Fax:
City, St, Zip: E-mail:
Bonding Company:
Address:
Mortgage Lender:
Address:
YES
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5"h Edition (2014) Florida Building Code
0
Revised: June 30, 2015 Permit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
it ature of Owner/Agent Date
C> 0,
Print Owner/Age 's Name
Commission # FF 976440
E*M's March a 2020BondedThruTroyfainInsurance800-385 7019 Owner/
Agent is Personallyor Produced
ID Type of ID W\o k
1 CQ,VlI-"'e- Signature
of Contractor/Agent Date GOS%
Ke1 Print
Contractor/Ag is Name Signature
of-NotaryVStaie of F ri Date Yk -,
MARISOLMOJIC 1'
FF 976440 omm, E
p1res Mar t
Aarch
2 , 4020 Foc
c°' Bonded inruT Bin lnsurnce 800385.7019 C
nti`het own to Me or Produced
ID Type of ID BELOW
IS FOR OFFICE USE ONLY Permits
Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction
Type: Total
Sq Ft of Bldg: Occupancy
Use: Min.
Occupancy Load: New
Construction: Electric - # of Amps Fire
Sprinkler Permit: Yes No APPROVALS:
ZONING: ENGINEERING:
COMMENTS:
of
Heads UTILITIES:
FIRE:
Flood
Zone: of
Stories: Plumbing - #
of Fixtures Fire
Alarm Permit: Yes No WASTE
WATER: BUILDING:
5r2%1 Revised:
June 30, 2015 Pennit Application
NewSouth 820 East Altamonte .1Itafnol)ita Springs, FL32701
407-2ti1-227277 1,407-261-2278 fax
WINDOWSOLUTIONS www,NewSabthWindow.com
M d ' ib—I th a 9th Date L — " a a In ea ... 9r 6 0
To E-mail
Home Phone .,2y
City 5 State Zip 12— 2 2_ Business (Mr. / Mrs.)
Replacement Windows •Entry & Patio Doors • Storm Doors • Impact Resistant l
WHOLESALE & RETAIL WINDOW CONTRACT
N—c—th w,nH— ,nI, i.ns a ,FPs to measure. manufacture or furnish and service the following custom made s
Doors
the amount CTIPI it ATFn Rri nw•
AllNewSouthVantage Series Windows include Double Pane, LoE glass with Argon gas, and 12 pght fusion welded corners. All
eVantage windows are Sashlite"sealed'and vacuum tested with aT m enhanced and frame: _ Co1or.
0o_rM:,Fwhole wi.AtfQkvhlte Or- Chern9ond Q1tltgai (exterior only) O __ .-__ r^1t4LSII)fl Whin O ran J! Colou mry my avhly hom u_m '(I ilia6 I+
n,le in'cdbrl T, QUANTITY
I OBSdURE GLASS YES O QUANTITY p COILTRIM f C COLOR: TEMPERE
GLASS
O YES wtrNovr caross"
m our caosa cam - aru
LOCATION: cws smF LOCATION:, NO 0 Vantage
antage tyantage DOUBLE HUNG
VANTAGE SERIES HALF -SCREEN)
CASEMENT FULL
SC0.
EEM O Fpll
Screen 2 LITE
SLIDER VANTAGE SERIES HALF-SCREF.
N) DOUBLE CASEMENT
1W0 FULL
SCREENS) O:FUII
Screen j PICTURE WINDOW
VANTAGE
SERIES. i DOUBLE
CASEMENT
WITH FIXED
CENTER 0405cREi;N1
3 LITE
SLIDER PICTUREWINDOW VANTAGE
SERIES
I y
AWNING&
HOPPER
TILT WINDOW FULL SCREEN)
obr ran
rWOSCREF.NS)
optrond Wiiteo
ony. PICTURE WINDOW
WITH DOUBLE HUNGS
PATIO DOORS
0 5/0 a 6/6 (59172• x 791/2'T O 610
X6/6 (711/T X791/2j Indicatethe 610
X We(711fT X951/2-) VANTAGE SERIES
tw0/1ArF5Cflf.
I:NS): irecl'ron
of slide 06/0 X 6/6 (951tr X 791/2 XO of
Ox 139/0 XWe(1071/2-X791/2 OrN OEYE9ROW
SHAPED WINDOWS (
NOT FOAM ENHANCED) ROUOUNp 9 OiMe O(
ORA(DRAOTHER
WINSeACOGRID STYLES
STANDARD CONTOUR BRASS/GOLD/PENCIL Was htshome builtpnorto 19787 El Ye No I Cclonial
Prairie Open Prairie I I
i If ye
the undersigned agress to the ter s and con tions'
of the NewSouth lead Safe Work I FL-
IPractcesAddendu . r,
gniturt '
TOTAL NUMBEROFDO
ONTHISORD ' s OTHER: Customer agrees
to
allow NewSouth to display a yard sign until 30 days after completion. TWO YEARS FREE IN HOME SERVICE BUYER'S RIGHT
TO CANCEL Total price" m' $ BUYER MAY
CANCELTHIS
CONTRACT BY DELIVERING WRITTEN NOTICE TO THE SELLER
AT ANY TIME PRIOR TO MIDNIGHT OF THE TAD Down $ ? 3 RUSINE,SS.DAYAFTER. THE DATES -OF THIS TRANSACTION. BUYER MAY.. payment USE THIS CONTRACT
AS THAT NOTICE BY WRITING "I" HEREBY CANCEL AT THE BOTTOM
AND ADDING BUYER'S NAME AND ADDRESS, THE BalanceInstallatpayable Balance payable or} NOTICEMUSTBE DELIVEREDTOTHE
SELLER ATTHE ADDRESS SHOWN er y $-77 ABOVE. 0 Bank Financing .
Cash,onCompletion An material is guaranteed
to Ue as specinea: All work is to be completed 'In -a workmanlike mane contract is valid only
with proper, signatures. NewSouth shall not be held responsible for time a other matters beyond its
control. Owner agrees that the equity in this property is security for this order goods, it Is
not subject to cancellation except as stated above. Start installation approximi promises can cause misunderstandings,
therefore this contract constitutes the entire understandii collateral, verbal or otherwise,
shall be binding, unless signed by both parties. NewSouth to Ter salgs d discounts aliott
II charges included above.Thank you for your order. D _ x XB ers
Signature ,,,SouthRepresent, x Buyer's Signature
NewSouth
Manufactu according to standards and
practices. This material delays, strikes, acts
of God or any; ntract Since this contract
calls for made to V eeks from above
date. -Verbal fthepar ies,andnootherunderstanding, e:,
and haul away
all job relateddebris. All g Authorized Officer
J
1
THIS INSTRUMENT PREPARED BY:
Name: BRIDGET LAMBERTON
Address: 820 E. ALTAMONTE DR
AI TAMONF SPRINGS FL 32701
NOTICE OF COMMENCEMENT
State of Florida
County of Seminole
Permit Number: Parcel ID Number:
GR(-t' I•IT 1'IAL0Y: SEt'I:1140LE C.01114 T Y
CLER'. OF C):FtCl.11.T C00.1• C'Ot'IF"I'ROL.LER
R,f% J6,9 1='_s 1.109 (1F's)
CLERK'S t 2017039889
REi; HED 0 12-r/2011 09=30',52 (11
RECORD114G FEES $1.0„00
FiECORDEf.) BY
12-20-30-511-0000-0270
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with
Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement.
DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available)
LOT 27
MONROE MEADOWS
PB 46 PGS 16 & 17
DESCRIPTION OF IMPROVEMEN :
I t I to 0 U I, IA (Y)AI S
OWNER INFORMATION:
Name: JAMES R CAWTHON
Address: 166 KELLY CIRCLE SANFORD, FL 32773
Fee Simple Title Holder (if other than owner) Name:
CONTRACTOR:
Name: NEW SOUTH WINDOW CRC 1330822
Address: 820 E ALTAMONTE DR ALTAMONTE SPRINGS, FL 32701
Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served
as provided by Section 713.13(1)(b), Florida Statutes.
Name:
In addition to himself, Owner Designates
To receive a copy of the Lienor's Notice as Provided in
Section 713.13(1)(b), Florida Statutes.
Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a
different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13,
FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A
NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true
t he best of my kwled a an belief.
Al
Owner's Signature Owner's Printed Name
Florida Statute 713.13(1)(g): "The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead."
State o %Countyof The
foregoing instrument was acknowledged before me this ekday of I 2011 by
C
C6xx 0 " . Who is personally known to me Name
of person making statem nt , , I /' c(
r
y OR
who has produced identificatio Identification produced: \VI yC_ MARISOLMOJICA
ELE7019
Notary Si je w
a
it Q O
0
I—
O z
O a
D
j
z of
0 0OF:
rU W
0O
CO O zz0
UJ
UU<LA o
mewsouth
Motes:
OWWIlNDt>ro utt t l Window
Specification and Detail Pursuant
to Con t ' South Window Solutions Cust
er: Address:
V
ell City -"—
ip ,22 3 Phone: (
H}& r S f (w)' 1
T
First
Floor j/
fl Coniract
i?ate. _ F or, Re Frames I Screens Insulated Glass Unit Grid Options Customer
Approval; X
w
GI3SS Type
o
3
o c
WINLocationStyleCaiur
EXTf#
W
x H) Sales
measure V5r
x H) Opening
Size tW
x Hj Make
Size 2
l
r v l ^t x x J x
x x s 4
J
x i X.. x i
uN
O
y 6G O
c V N
n
r- n
Q m O C cm-0 rnOC=m2CZn Cl) Z —
m
D m o m6
Z 33
m
O —
TiQ>TmnGOM
O O02>midom Z2rm<mC 0mcn
o
p
O00 m
OODZom-
r- r— 7 D
O SZ ;mpDX4m
m- OmpOjnmO Z
Jm m i
0 PEZ
o
0 OOM=m + i--im
m!:; Co m mzCU3
r
Z
Znmm
O
Om0ZmZmmmZCm<nm
McnZr-
i>D i
4 .r
BCIS Home Log In User Registration i Hot Topic Submit Surcharge I Stats & Facts Publications FBC Staff BCIS Site Map I Links Search
Ire itla
a'! Product Approvalr ` . °' USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
ter Rt'= .' FL # FL15378-R2
Application Type Revision
Code Version 2014
Application Status Approved
Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
Date Submitted
Date Validated
NewSouth Window Solutions
4901 oak fair blvd
tampa, FL 33610
513) 284-0129
danochstein@newsouthwindow;com
Vivian Wright
rickw@rwbldgconsultants.comi',
o
Windows
Double Hung
Certification Mark or Listing H
National Accreditation & Management Institute
Ryan 3. King, P.E.
Validation Checklist - Hardcopy Received
Standard
AAMA/ W DMA/CSA 101/I. S.2/A440
AAMA/ W D MA/CSA 101/I. S.2/A440
ASTM E1886
ASTM E1996
Method 1 Option A
09/30/2015
09/30/2015
Year
2008
2011
2005
2005
Date Pending FBC Approval
Date Approved
Products
10/01/2015
FL # Model, Number or Name
15378.1 a. DuraGard Double Hung Window
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15378.1 for Design Pressure Ratings, any
additional use limitations, installation instructions and
product particulars.
15378.2 I b. DuraGard Double Hung Window
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15378.2 for Design Pressure Ratings, any
additional use limitations, Installation instructions and
product particulars.
15378.3 I c. Sashlite Double Hung Window
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15378.3 for Design Pressure Ratings, any
additional use limitations, installation instructions and
product particulars.
15378.4 1 d. Sashlite Double Hung Window
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15378.4 for Design Pressure Ratings, any
additional use limitations, Installation instructions and
product particulars.
Description
DuraGard New Construction (Nail Fin) "Non -Impact" Vinyl
Double Hung Window (X/X - configuration; Max Size 54 x 75)
Certification Agency Certificate
FL15378 R2 C CAC NAMI Cert for 15378.1 (54 x 75)Ddf
Quality Assurance Contract Expiration Date
12/31/2019
Installation Instructions
FL15378 R2 II INST 15378.1 Ddf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15378 R2 AE EVAL 15378.1.0df
Created by Independent Third Party: Yes
DuraGard Replacement "Non -Impact" Vinyl Double Hung
Window (X/X - conlIguration; Max Size 54 x 75)
Certification Agency Certificate
FL15378 R2 C CAC NAMI Cert for 15378.2 (54 x 75) Ddf
Quality Assurance; Contract Expiration Date
12/31/2019
Installation Instructions
FL15378 R2 II INST 15378 2 odf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15378 R2 AE EVAL 15378 2 odf
Created by Independent Third Party: Yes
Sashlite New Construction (Nail Fin) "Non -Impact" Vinyl
Double Hung Window (X/X - configuration; Max Size 54 x 75)
Certification Agency Certificate
FL15378 R2 C CAC NAMI Cert for 15378.3 (40 x 60) Ddf
FL15378 R2 C CAC NAMI Cert For 15378.3 (54 x 75),pdf
Quality Assurance Contract Expiration Date
11/30/2019
Installation Instructions
FL15378 R2 11 In t 15378.3.odf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15378 R2 AE EVAL 15378 3 Ddf
Created by Independent Third Party: Yes
Replacement "Non -Impact" Vinyl Double Hung
X/X - configuration; Max Size 54 x 75)
Certifidation Agency Certificate
2ualit Assurance Contract Expiration Date
03/31 019 -
nst4flation Instructions
V rifled By: Lyndon F. Schmidt, P.E. 43409
I reated by Independent Third Party: Yes
Evaluation Reports
j FL15378 R2 AE EVAL 15378 4 Ddf
Created by Independent Third Party: Yes
15378.5 1 e. DuraGard Double Hung Window
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: See INST 15378.5 for Design Pressure Ratings, any
additional use limitations, installation instructions and
product particulars.
DuraGard New Construction (Nail Fin) "Impact" Vinyl Double
Hung Window (X/X configuration; Max Size 40 x 72)
Certification Agency Certificate
FL15378 R2 C CAC NAMI Cert for 15378.5 (40 x 70) Ddf
Quality Assurance Contract Expiration Date
12/31/2019
Installation Instructions
FLIS378 R2 Il INST 15378.5.Ddf
Verified By: Lyndon' F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports:
FL15378 R2 AE ES/AL 15378.5.Ddf
f
Created by Independent Third Party: Yes
15378.6 f. DuraGard Double Hung Window DuraGard Replacement "Impact" Vinyl Double Hung Window
X/X - configuration; Max Size 40 x 72)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15378 R2 C CAC NAM] Cert for 15378.6 (40 x 70).Ddf
Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes
Impact Resistant: Yes 12/31/2019
Design Pressure: N/A Installation Instructions
Other: See INST 15378.6 for Design Pressure Ratings, any FL15378 R2 II INST 15378.6.Ddf
additional use limitations, installation instructions and Verified By: Lyndon F. Schmidt, P.E. 43409
product particulars. Created by Independent Third Party: Yes
Evaluation Reports
FL15378 R2 AE EVAL 15378.6.Ddf
Created by Independent Third Party: Yes
ttaE rvext
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone;?850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions;please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4S5, F.S. must provide the Department with an email address If they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address,. please provide the Department with an email address which can be made available to thelpublic. To determine If you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
a_
Credit Card
Safe
In!XI. tb Ag
1 1
Sashlatb
Double rung Window
NON -IMPACT"
GENERAL NOTES
1. This product has been evaluated and is in compliance with the 5th Edition (2014) Florida
Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone"
HVHZ). See the Certification Agency Certificate for sizes, specifications and ratings.
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment
to base material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind bome debris protection this product is required to be
protected with on impact resistant covering that complies with Section 1609.1.2 of the
FBC.
4. For 2x stud froming construction, anchoring of these units shall be the some as that
shown'for"2z'buck masonry consfinicNor.
5. Site conditions that deviate from the details of this drawing require further engineering
analysis by a licensed engineer or registered architect.
TABLE OF CONTENTS
SHEEN I DESCRIPTION
1 Typical elevations, design pressures & general notes
2 Vertical & horizontal cross sections
3 Vertical & horizontal cross sections
4 Buck & frame anchoring
5 Components
6 Bill of materials and glazing details
54"
MAX. OVERALL
FRAME WIDTH
X
r
W0
In
Q
X
I
1
t
MAX
FRAME
DIMENSION
MAX
D.LO.
DIMENSION
GLASS
TYPE
DESIGN PRESSURE
PSI)
POS. I NEG,
54.0- X 7S.0' 48.25" X 3C V G1 20.0 25.0
54.D- X 63.0- 48.2S' x 28.5- Gi 30.0 35.0
48.0- X 72.0" 42.2Y X 33.0- G 1 30.0 35.0
E: 6/17/15
U: N. T. S. °
BY: JK m
c. m: LFS
TWIN -NO-
FL- 15378.4 0
D !O
n a. 4-0 n
3 2 i • . I •' c q 2 n
LOCKS (21 11 t t %o n. i
B" FROM EACH END
f
J a ''
Or' \ ` ryi n
o
TFv
d 56
LL
30
33 v
C=
4 3
z
D Gl . 21 z oNo2zc
14 22 z $2
3 3 11 m Fa
EXTERIOR O o
1-I14"MIN.
B INTERIOR
EMB. (TYP.)
a a
12 m
C 31
o
15 Gl 9
INTERIOR
s
Ln
u, z
32 z
W
aZ
I(1 pB
o<
O
GI 1 TTIT - z c
4
U
WE 6/17 15
0OEXTERIOR
F
score N.T.S.
5
3 OE a —
Q
r owo. a JK m
z aoc: ey: IFS 3
E
D 2 VERTICAL CROSS SECTION
opnarru uo:
1 HORIZONTAL CROSS SECTION ai FL-15378.4 0
2 2. Buck Masonry Construction 2 2% Buck Masonry Conslrucron 71 a
weer 2 OF 6
A•' n
G2
z
a
INTERIOR %V'.
C
37 15 Pf
z
G1 a
m 6
11
o z
9 r
E z mO° Z c1i
P t \ \ Q t °° °c w
N 7 m d `a
a
ia
q c ai
3 d Lim
a -
3
2022N
3 00U
G1 m9xW
1-1l4"MIN. _ 8 EXTERIOR m ua
EMB. (GYP.)
0
o 0
HORIZONTAL CROSS SECTION
a a
3Jsno..n •ith IX s o—ouck Gl m
EXTERIOR - -y INTERIOR
Gl
9
EXTERIOR ( 5 1 INTERIOR oC=X)0:3 - —"--0
000
30
32 — 30
ow
In
2 a
C
w
E
e i
V • ~ h
a um: 6/17/15 0
sari N.7.5.
w owG. ar: JK m
e VERTICAL CROSS SECTION -
Masorxy Sig 3 Masonry
CROSS SECTION o«. a,..LFs3
FL-15378.4 0
SHEET 3 or 6
2x
BU
MASONRY
OPENING
0
4.'
nP.)
L
2X SUB
BUCK
FRAM
MASONRY
OPENING
A"
L
2X BUCK ANCHORING
FRAME ANCHORING
2X BUCK
3
iS
CONCRETE ANCNOR NOiF3
1. Concrete anchor locations at the comers may be adjusted to maintain the min.
edge distance to mortarjoinh.
3 2. Concrete anchor locations noted as "MAX. ON. CENTER" must be adjusted to
maintain the min. edge distance to mortarjoinh. additional concrete anchors
may be requirad to ensure the "MAX. ON CENTER" dimension are not exceeded.
3. Concrete anchor table:
ANCHOR ANCHOR MIN. MIN. CLEARANCE MIN. CLEARANCE
SITE EMBEDMENT
70 MASONRY- TO ADJACENT
TYPE
e
EDGE ANCHOR
ITW
1/4-1.1/4" 2 4"
TAPCON
ELCO ro 1/4" 7.1/4" 1" 4"
ULTRACON
WOOD SCREW INSTALLAIKX4 NV In
I. Maintain a minimum 5/3" edge distance. I"end distance. d I' o.c. spacing of
wood screws to prevent the splitting of wood.
IX SUB
BUCK
FRAME —
MASONRY
OPENING
Tlllll111/ j,'
I W
yam
J O N m
0
M
P
nP.
I
I
FRAME ANCHORING
IX BUCK
d
oN,2
v Z O Z U
m
In 9 ° 0 (Ln ' mdam
o
i o ? qE y
S 3d
3
o w
qV
w XZWS
m m
o
a a
m
DAB= 6 1 ZZ 15 zb
saut N. T. S.
owc. er: JK m
Cw GY: LFS ''
5
ow,wlwc NO.:
N
FL-15378.4 0
n
sM-er 4 or 6 ,g
EXIRUOfO VINYI FRAME
1.06•
ANo
O
0.125'
I I-
2 REINFORCEMENT
b.
o
lI.1
0
LOCK RAIL REINFOCEMENT
1.565 -
000
0.075"
KEEPER RAIL
7
4 - TOP RAIL
1.45
0.85" -
I
0
D
8 FOP SASH Sillf
1 EXTRUDED VINYL SILL
2.17"
P
0.075"
1-- 1.42" --I
BOTTOM RAIL
0.96" --
L
o0.13" -
I.
I
13 REINFORCEMENT
11111I111
C ............. Q n
2
i-0 da
O n o Z
Ea
8=
i u u
9
VVV 4
C 2 l
3 EXTRUDED VINYL JAMB
cj
026' --1 F-- 0.2T' 1--
GLA ZING BEAD 1 KEEPER GLAZING 8FA0
1.35" UF-
D
0.08" -
D
o00
BOTTOM SASH STILE O LOCK RAIL
a
n I
r 4 i
o . o
aZ
aTE- 6/ 1 7/ 15
SC. E: NJ.S.
DWG. Err: JK °
GNk. a: LFS 3
wuvAuc .w.: °
FL-15378.4 n
s.Ecr 5 or 6
it
C4*
9
ci
y,.YJ t 'c of n
U G Z
maa`
LL
1/2 GLASS BITE
o`
F W pJ
1(4" O A GLASS THK
3
1/8"ANNEALEDGLASS
o
Z
Wo
U U
r O AIR SPACE i m?
OV
LL
20
N
mQ
E O g o
o
I/&'ANNEALED GLASS a a
o
10 9
THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO 8E PRODUCED GLAZING DETAIL v~, v
BY EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS".
K
3W x
t
z
cQlQ
W
N
o
a
O
Q J
f aL
Z U
a E 6117115 =
0
xuF: N.T.S.
o rc. BY: J{( m
s
i
cw. . en LFS ;
rc
onawwc w.:
n
FL- 15378.4 0
N
BILL OF MATERIALS
REM OESCRII110N MATEIUAI
A 1 X BUCK SG >= 0.42 WOOD
B 2XBUCKSG>=0.42 WOOD
C 1 /4" MAX. SHIM SPACE STEEL
D I /4" X 2-3/4" PfH ELCO OR ITW CONCRETE SCREW STEEL
E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE
F 8 X 7' PFH WS (1-1/2" MIN. EMBEDMENT) STEEL
P 1 /4" X 2-3/4" PH ElCO OR ITW CONCRETE SCREW STEEL
I HEAD-441F' PVC
2 SILL-442F' PVC
3 JAMB-443F` PVC
4 TOP RAIL - 414' PVC
5 BOTTOM RAIL - 427' pyC
6 LOCK RAIL - 426` PVC
7 KEEPER RAIL - 423` PVC
8 TOP STILE - 408• PVC
9 GLAZING BEAD - 448' PVC
10 GLAZING SILICONE (SashSeal)
1 I LOCK RAIL REINFOCEMENT - 452 ALUM
12 REINFORCEMENT ALUM.
13 REINFORCEMENT - 458 ALUM.
1 d KEEPER GLAZING BEAD - 449• PVC
15 BOTTOM STILE - 428' PVC
20 LIQUID APPLIED DESICCANT (SoshDri)
21 KEEPER - TRUTH #C41275
22 LOCK ASSEMBLY -TRUTH RA30700401
30 CENTER FIN PILE - .187 X .190
31 CENTER FIN PILE - .270 X .220
32 FOAM SEAL -BOTTOM RAIL - AMESBURY k32692
33 FOAM SEAL -TOP RAIL - AMESBURY #32012
i -
k.._...._...._..-.- ...-.. 72..
BCIS Home Log In User Registration Hot Topics ( Submit Surcharge Stats 8 Facts I Publications FBC Staff BCIS Site Map i Links Search
ba -- Product Approval
Ltd 1, USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
r- i
FL # FL16842-R3
L`"1" M " `
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer NewSouth Window Solutions
Address/Phone/Email 4901 oak fair blvd
tampa, FL 33610
513) 284-0129
danochstein@newsouthwi ndow.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com'
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Horizontal Slider
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2017
Validated By Ryan 1. King, P.E.
f Validation Checklist - Hardcopy Received
Certificate of Independence FL16842 R3 COI CERTIFICATE OF INDEPENDENCE cc.pdf
Referenced Standard and Year (of Standard) Standard Year
AAM A/ W DM A/CSA 101/I. S.2/A440 2008
AAMA/WOMA/CSA101/I.S.2/A:440 2005
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2005
TAS 201, 202, 203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Go to Page 10
Method 1 Option D
12/20/2015
01/14/2016
01/18/2016
04/12/2016
10 16 Pagel /20 0
FL # Model, Number or Name Description
16842.1 a. 9500 Slider XO Extruded Vinyl "Non -Impact" Horizontal Sliding Window
f utilizing a Nail Fin Installation (XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II Inst 16842.1.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.1 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.1.odf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
16842.2 b. 9500 Slider XO Extruded Vinyl "Non, -Impact" Horizontal Sliding Window with
Flange Installation (XO or OX configurations)
i
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II INST 16842.2.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Report,.
Other: See INST 16842.2 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.2.odf
additional use limitations, installation Instructions and Created by Independent Third Party: Yes
product particulars.
16842.3 C. 9550 Slider XO - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a
Nail Fin Instal lation'(XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II Inst 16842.3.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.3 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.3.odf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
16842.4 d. 9550 Slider XO - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window with
Flange Installation (XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II Insh 16842.4.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.4 for Design Pressure Ratings, any
additional use limitations, installation instructions and
product particulars.
FL16842 R3 AE Eval 16842.4.odf
Created by Independent Third Party: Yes
16842.5 e. 9550 Slider XO - Impact Rated - Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a
HVHZ Nail Fin Installation (XO or OX configurations)
1 Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16842 R3 II Ins[, 16842 5.odf lApprovedforuseoutsideHVHZ: Yes Verified By: Lyndon' F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.5 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.5.odf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
16842.6 f. 9550 Slider XO - Impact Rated - Extruded Vinyl "Impact" Horizontal Sliding Window with
HVHZ Flange Installation (XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16842 R3 II Inst 16842.6.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.6 for Design Pressure Ratings, any FL16842 R3 AE E'val 16842.6.odf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
16842.7 g. 9500-3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window
utilizing a Nail Fin Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II Inst 16842.7.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.7 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.7.odf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
16842.8 h. 9500-3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window with
Flange Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II Inst 16842.8.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Design Pressure: N/A
Created by Independent Third Party; Yes
Evaluation Reports
Other: See INST 16842.8 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.8.pdf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
16842.9 1. 9550-3 Slider XOX - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a
Nail Fin Installation,' (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II Inst 16842.9,pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.9 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.9.pdf
additional use limitations, installation Instructions and Created by Independent Third Party: Yes
product particulars.
16842.10 j. 9550-3 Slider XOX - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window with
Flange Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II Inst 16842.10.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.10 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.10.odf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
i product particulars.
16842.11 k. 9550-3 Slider XOX - Impact Extruded Vinyl "Impact' Horizontal Sliding Window utilizing a
Rated - HVHZ Nail Fin Instal lation"(XOX, configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ: Yes FL16842 R3 II Inst 16842.1l.odf
i Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.11 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842,11.pdf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
16842.12 I. 9550-3 Slider XOX - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window with
1 HVHZ Flange Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ: Yes FL16842 R3 II Inse16842.12.odf Approved
for use outside HVHZ: Yes Verified By: Lyndor% F. Schmidt, P.E. 43409 Impact
Resistant: Yes Created by Independent Third Party; Yes Design
Pressure: N/A Evaluation Report Other:
See INST 16842.12 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.12.pdf additional
use limitations, Installation instructions and Created by Independent Third Party: Yes product
particulars. I
16842.
13 m. DuraGard Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing
a Nail Fin Installation (XX, configuration) Limits
of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II INST16842 13 odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409ImpactResistant: No -
Design Pressu t.N*/A Created by Independent Third Party: Yes
Other: Seg.INST 168yy2:13 for Design Pressure Ra s any
Evaluation Reports
FL16842 R3 AE Eval 16842 13 odf
add19nal use limitafons, installation Instructions and
product particulars. Created by Independent Third Party: Yes
16842.14 n. DuraGard Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XX,
configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II INST 16842 14 odf
Approved for use outside HVHZ: Yes
Impact Resistant: No Verified By: Lyndon F. Schmidt, P.E. 43409
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See INST 16842.14 for Design Pressure Ratings, ny
Evaluation Reports
FL16842 Eval
additional use limitations, installation instructions and
R3 AE 16842 14 odf
Created by IndePendent Third Party: Yesroductparticulars.
16842.1 I o. DuraG d— Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window
utilizing a Nail Fin installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II INST 16842 15 odfApprovedforuseoutsideHVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409ImpactResistant: No
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See INST 16842.15 for Design Pressure Ratings, any
Evaluation Reports
EL16842 R3 AE Eyal 16842,15,pdf
additional use limitations, installation instructions and j
Created by Independent Third Party: Yesproductparticulars.
1
116842.16 p. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window with
I Flange Installation (XOX, configuration)
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
Approved for use outside HVHZ: Yes FL16842 R3 II INST 16842 16 odf
Impact Resistant: No Verified By: Lyndon F. Schmidt, P.E. 43409
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See INST 16842.16 for Design Pressure Ratings, any
Evaluation Reports
FL16842 R3 AE 6M 16842 16 odf
additional use limitations, installation instructions and
product particulars. Created by Independent Third Party: Yes
116842.17 q. Sashlite Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window
utilizing a Nail Fn Installation (XX, configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II INST 16842 17 odfApprovedforuseoutsideHVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409ImpactResistant: No Created by Independent Third Party: YesDesignPressure: N/A Evaluation Reports
Other: See INST 16842.17 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 17 odf
additional use limitations, installation instructions and Created by Independent Third Party: Yesproductparticulars.
16842.18 r. Sashlite Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XX,
configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No FL16842 R3 II INST 16842 1 a odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409ImpactResistant: No
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See INST 16842.18 for Design Pressure Ratings, any
Evaluation Reports
FL16842 R3 AE Eval 16842 18 odf
additional use limitations, installation instructions and Created by Independent Third Party: Yesproductparticulars.
16842.19 s. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window
utilizing a Nail Fin Installation (XOX, configuration)
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
i Approved for use outside HVHZ: Yes
Impact Resistant: No
FL 16842 R3 II INST 16842.19.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409fIDesignPressure: N/A Created by Independent Third Party: Yes
Other: See INST 16842.19 for Design Pressure Ratings, any Evaluation Reports
FL16842
additional use limitations, installation instructions and R3 AE Eval 16842 19 df f
Created by Independent Third Party: Yesproductparticulars.
16842.20 I t. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XOX,
configuration)
Limits of Use
low—auouun In5Cructions
Approved for use in HVHZ: No FL16842 R3 II INST 16842.20.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.20 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.20.pdf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
Go to Page ( (0 0 Page 1 / 2 0 0
Sack iaraxi
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone:'850-487-1824
V
The State of Florida is an WEED employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section
455.275(I), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
a Zi
Credit Card
Safe
I
WINDO SOLUTIONS
4901 Oak Fair Blvd., Tampa, FL 33610
DuraGard Slider XX
NON -IMPACT'
GENERAL NOTES
1. This product anchoring drawing has been evaluated and is in compliance with
the 5th Edition (2014) Florida Building Code (FBC) excluding the "High Velocity
Hurricane Zone" (HVHZ). See the Certification Agency Certificate for sizes,
specifications & ratings.
2. Product anchors shall be as listed and spaced as shown on details. Anchor
embedment to base material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product is
required to be protected with an impact resistant covering that complies with
Section 1609:1.2 of the FBC.
4. Site conditions that deviate from the details of this drawing require further
engineering analysis by a licensed engineer or registered architect.
TABLE Of CONTENTS
SHEETIt DESCRIPTION
1 Typical elevations, design pressures & general notes
2 Vertical & horizontal cross sections
3 Vertical & horizontal cross sections
4 Buck & frame anchoring
5 Bill of materials, glazing details and components
72' MAX. OVERALL
FRAME WIDTH
I
FRAME
DIMENSION
DAY LIGHT
DIMENSION
GLASS
TYPE
DESIGN PRESSURE
POS. NEG.
72tr x 65.0" 32.56' x S8.5" GI 30.0 30.0
720" x 56.(r 32.56" x 49.5 Gl 35.0 35.0
wE: N.T.S. i
vc. w: JK m
K Br: LFS 3
uv"xc wo.:
rz
FL- 16842. 14 a
EE -- t OF 5 Q
1-1 /d' MIN_
IN TERN- R
EXTERIOF
QHURILUNTAL CROSS SEUIUUN
2X Buck Masonry Construcllon
NOTE: Sheet Metal Screws must
penetrate a min. of 3 threads
through at least 2 sheets of metal.
Q 0 INTERIOR
EXTERIOR
HORIZONTAL CROSS SECTION
Q Steel Stud Construction
Zd
EXTERIOR INTERIOR
Q 2X •Buck unsonry Construction, — w
Q. Z n
v 41 Q-a
J O p 'A
rllt Ilt1 o n m z
ON
o v ozd
u 9rv o a
a N omaamY
w
cZoo ^ '
0 3a
o OZOZNO
o
x 1.,
cc cc
O_ GU
UI
w
a
0a uZ
mtZ
j
m
h
N
u
QO
z
WE320 12
i
i N.LS.
owc. ay: J{( m
3c.K, sr: LFS
a
11FA1MWAG No.:
FL— ) 6842.14 aw
s ET 2 OF 5
r- I
1 GG — O z ''4 is ` y n
on z
h °N
v v t5
C
Z,
a, ! Ep i m o
0
u X jK)
nn 'n SRc°m
v
a maa
E 4E 6
E `oZ
3
D 2 0 oZ
G1
2 3 EXTERIOR INTERIOR z
W
VERTICAL CROSS SECTION o fic i
3 = oU
EXTERIOR INTERIOR n nEXTERIORINTERIOR
m
3
223Q
u 0
o o
a
8
8 o
a • a , N Q
e ° e • p j
a Z U
wic 3 20 7 2 z
a
sctiE: N.T.S.
2 VERTICAL CROSS SECTION
oxo . m
3J [
VERTICAL CROSS SECTION BYcue. : LFS
Mason ry sill 3 MasonryA Dpi,wixc no.;
p
v
FL— 16842.14 o
N
stun 3 OF 5
6
2X SUB
BUCK
MASONRY
OPENING
4"
TYP.) —
to,_ II -
2X BUCK ANCHORING
CONCRETE ANCHOR NOTES:
I. Concreta an=lacoflom of the comers may be adjusled to motntatn the min,
edge dstance to moecrioinls..
2. Concrete oncfwriocallons noted a: MAX. ON CENTFX'must be odjusied to
molhtoln the min. edge distance to moHorjointt, adclill—d concrete anchors
may be required to ensure the MAX. ON CENTER' dimenslon ore not exceeded.
3. Concrete anchor table:
ANCHOR. ANCHOR MIN, MIN. CLEARANCE MIN. CLEARANCE
TYPE. - sqf- EMBEDMENT TO MASONRYEDGE....
T6AUJACENT
ANCHOR '.-
iTw
t/r T•i/r r r
TA CON
ELCo
1/4' t•tlr t" 4'
ULTRACON
WODUSCXEw MiALlA1rcJN IVV -
i. Molnfaln o minimum 5/8' edge avaronce. i' end distance. R i"o.c. spoctng of
wend saews to prevent the splitting of wood.
2X SUB
BUCK
MASONRY
OPENING
FRAME ANCHORING
z
J (0:..y> i
T
ow aZ
T U N
Bm v Z Z U
g LO g C W
56
ca °
eV yj
O Jd
w
W4
ui v
zq
oaz
m
2 cY n to
L1 s Q
d o
0
a a
F
z
nin
O
oOZU
pldE; 3/20 t 2
SCAU N.LS.
w0. BY: JK
CHK. BY: LFS
op'.NO
FL-16842,14 0
nSHM4or5
8
Bltl OF MATERIALS
REM A DESCRIPTION MATERIAL
A IA BUCK (SG>=DAY) WOOD
8 2X BUCK (SG >=0.42) WOOD
C 1 /4" MAX. SHIM SPACE
D 114' X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL
E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE
F 10 X 7' PPH SMS (1-1/7' MIN. EMBEDMENT) STEEL
G 1/4" X 2-3/4" HH ELCO OR ITW CONCRETE SCREW WOOD
K 06 X 1-114" PFH SMS STEEL L
10 PPH SELF -DRILLING SMS STEEL X _
STEEL STUD Min, Thk .033" (ASTM A653 GRADE 33 Fy=33 ksi min., Fu=45 ksi min.) STEEL I
FRAME PVC 2
SASH' PVC 3
GLAZING BEAD' PVC 4
GLASS SETTING BLOCK PVC 5
PULL STILE' PVC 6
LOCK STILE' PVC 7
MEETING STILE' PVC 8
ANTI-UFT & SILL TRACK' PVC 10
GLAZING SILICONE (DOW 1199) 11
REINFORCEMENT (6063 - T5) ALUM 14
LOCK ASSEMBLY (TRUTH) STEEL THE
APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY EXTRUDERS
LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". 1 /
7 GLASS BITE 7/
8-0 " AGLASS THK. IJNEA,LFQG-
6s,$. . i-AIRSPACE
I -1/
B" ANNEALED GLASS FOAM SPACER
Gl GIADNGDETAft
T FRAME
444F o
o
0
6
0.93" --{
OLOCK STILE
4948 0.
27'
0.09'
GLAZING BEAD
I T
T
RHNFORCEMENT v 44684800.28'
c o
Uo 1.
47
2 SASH
4249 0.06" -- -
T- QO
f_Q
0.
07" - - o 1_ I
0.
94" ----{
S PLILL
STILE 475E IT
O.
O7" -
4 i--
0.07" ANTI-UFT&
SILL TRACK MEETING SFIIE 206 4938
N o
z
W Q
N f
i F
w
s
N Q
n o
O 0
Z E:
3120112
c z ALL' N.
T.S. o ro. er:
JK m LFS ? TAMING
NO.:
V FL-
16842.
14 0 Im 5
or 5 i 11
NewSouth
WINDOW SOLUTIONS
To Whom It May Concern:
820 E. Altamonte Springs Dr.
Altamonte Springs, FI 32701
Phone: (407) 261-2277
Fax: (407) 261-2278
Contact Email:
hollyholmberg@newsouthwindow.com
I, Samuel Eli Ochstein, hereby authorize the following named person (s) to sign, apply for and purchase
permits and/or licenses for New South Window Solutions of Orlando.
This list is to replace all others previously issued, which are now to be considered null and void.
TYLER LEE
FRED BROWN
JUSTIN SHAW
TIM NAGLE
Job Address: 166 KELLY CIRCLE SANFORD FL 32773
Sincerely,
Samuel Eli Ochstein
CRC1330822
State of Florida, County of SEMINOLE
Sworn to and subscribed before me, this 20TI day of APRIL, 2017, by Samuel Eli Ochstein, who is
personally known to me and did not take an oath.
Marisol Mojica
Notary Public
State of Florida
Expires: March 29, 2020
S;FYP,B,, MARISOLMUCA
Commission # FF 976440
MarchExpiresEx 29, 2020p
vBondedThruTro Fainl800.385.7019 nsurance
REQUIRED INSPECTION SEQUENCE
IBuILID:ING PERMIT
Min Mays )Ins ection beset g n
Footer / Setback
Stemwall
Foundation / Form Board Survey
Slab / Mono Slab Prepour, .
Lintel / Tie Beam / Fill / Down Cell
Sheathing — Walls
Sheathing — Roof
Roof Dry In
Frame
Insulation Rough In
Firewall Screw Pattern
Drywall / Sheetrock
Lath Inspection
Final Solar
Final Firewall
Final Roof
Final Stucco / Siding
Insulation Final
Final Utility Building
Final Door
Final Window
Final Screen Room
Final Pool Screen Enclosure
Final Single Family Residence
Final Building (Other)
Address: 1" Y^9,1, --4 cv?_
EL ECTRI CA-L REItM IT
Min Maas Ins eQ tion Descrll ti®n
Electric Underground
Footer / Slab Steel Bond
Electric Rough
T.U.G.
Pre -Power Final
Electric Final
I 1 A` tT", 1:YFiY$^ y f" ; .' ar IDre V+? l iriA'A', S;i.#
Min Max lTns eeti®n Description
Plumbing Underground
Plumbing Sewer
Plumbing Tub Set
Plumbing Final
8 MECHAN.dCAL PE Rl1'II I
Min I Max
Mechanical Roug
Mechanical Final
Minn Max _-Inspection Description
Gas Underground
Gas Rough
Gas Final
REVISED: June 2014