Loading...
HomeMy WebLinkAbout225 W Seminole Bv 17-1266; SCREEN DOOR ENTRANCEWAYi MAY -3 2017 1 i BY: ------------ CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: i — /J_1P to Documented Construction Value: $ 1295.00 Job Address: 225 W. Seminole Blvd., Unit 407 Historic District: Yes No 0 Parcel ID: 25-19-30-520-0100-1407 Residential Q Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: screen with (1) door at entranceway Plan Review Contact Person: Donald G. Geissler, Jr Phone: 407 830-7778 Fax: 407 365-3194 Name Nancy & Stephen Koscoe Title: President Email: sunstatesiding@aol.com Property Owner Information Street: 225 W. Seminole Blvd., Unit 407 City, State Zip: Name Street: City, State Zip: Sanford, FL 32771 Phone: 407 417-1574 Resident of property? : yes Contractor Information Phone: Fax: State License No.: Architect/Engineer Information Name: Donald G. Geissler, Jr Sun State Siding, Inc Phone: 407 830-7778 Street: 510 Lake Lenelle Drive Fax: 407 365-3194 City, St, Zip: Chuluota, FL 32766 E-mail: sunstatesiding@aol.com Bonding Company: Address: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, \ furnaces, boilers, heaters, tanks, and air conditioners, etc. () FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5`" Edition (2014) Florida Building Code 0 Revised: June 30, 2015 Permit Application 10 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may he additional permits required frotn other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will he figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction ' credit will he applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all wor be done in compliance with all applicable laws regulating construction and zoning. Wte Signature of Contractor/Agent L}tie Donald G. Geissler. Jr na?ha of No' S r fi it---- . .1— 1 AVID J. DOWNER Notary Public, State of Fbrida F j commission# FF 182454 MY pomrn. eapirn Doc.16, 2018 Owner%Agent is Personally Known to Me or Produced ID_ K Type of ID Ft% OL Print C'ontractorlAgeriCs Name P<p 03 . a Signature oflota rv-State of Florida 1)ure DEBBIE BLAN70N P:Y COtilhdiSSION # rF 178648 l ' t EXPIRES: February 25, 2019 susdad'fhru14ota;+PuhllcUnAerwriters Contractor/AL!ent is Personalh Kno-,,n to Me or Produced ID _ Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building E4/ Electrical Mechanical Plumbing[] Gas Root'[] Construction Type: Occupancy Use: Flood 'Lone: _ Total Sq Ft of Bldg: Min. Occupancy Load: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: I I UTILITIES: ENGINEERING: FIRE: WASTE WATER: BUILDING 1 COMMENTS: ,, ' S a,,,3 C lo 0 c .r scrfP e tc os(J1x s , - a _ efre I SUN STAI- SIDING: INC. 310 LAKE L,ENELLF. DRIVE. CI-FULUOTA, `L 3276E 40 7 830-77 7 8 phone 07, 363-3194 fax Submitted to: PROPOSAL State License SCCO48423 Nancy Koscoe 225 W Seminole Bled, Unit 407 Sanford, FL 32771 DAI'E Job Location: SAME We propose to furnish all the materials and perform all the labor necessary for the completion ol: Furnish and install screen enclosure at entry lanai including custom screen door 3' x C 3") with "Tasman" locking handle, QJ-500 stele door manufactured by PCA Products, Inc. Site specific, engineer stamped plans and City of Sanford permit PROPOSAL # 4/142017 All material is auaraniced to be as specified and the above work to be performed in accordance with the drawill2s and specifications submitted for the above xyork and completed in a substantial workmanlike manner for the sum of: S L-59a00 S 1.295.00 S 300.00 With payments to be made as follows: FULL PAYMENT UPON COMPLETWON (We accept CASH or CHECKS only) Any alteration or deviation from the above specifications imrol ins extra cost will be executed only upon written orders and —ill become — extra cha,.e ---and alwve the estimate. All agreements contingent upon strikes_ accidents or delays beyond our control. Owner to carry fire. tornado, and other necessary insurance upon the above work. orkman's Compensation and Public Liability insurance on above work to be taken out by Sun State Sidin,.lnc. Submitted by D0.\'4LD G. GEI.SSU,-R- -IR, PRESIDE.NZ This proposal may be withdrawn by us if not accepted within 30 days. ACCEPTANCE OF PROPOSAL PLEASE ALLOW 6 TO 8 WEEKS FOR INSTALLATION" - TheThe above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to perform the work specified. Payment will be made as outlined above. Signature— -- J ------Date-- 4— ! 4 / Printed Name_ DESIGN CRITERIA: RECORD COPY APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2014 FLORIDA BUILDING CODE, 5TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23, WOOD AND AA ASM 35 AND AA ADM 1 2. ASCE 7-10.. WIND LOADS: 1-BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 AND TABLE 1604.5 RISK CATEGORY 1 2-BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION BASIC WIND SPEED. PARAGRAPH 1609.3.1 AND TABLE 1609.3.1 EQUIVQLENT BASIC WIND SPEED 130 MPH EXPOSURE C 3-SCREENED_ROOF ENCLOSURE TABLE 2002 4 GENERAL NOTES AND SPECIFICATIONS: 1-THE STRUCTURES INDICATED HERIN ARE DESIGNED TO BE INSTALLED WITHIN MASONRY OR WOOD FRAME HOST STRUCTURES OF ADEQUTE STRUCTURAL CAPACITY. THE CONTRACTOR SHALL VERIFY THAT THE HOST STRUCTURE IS IN GOOD CONDITION AND OF SUFFICIENT STRENGTH TO SUPPORT THE PROPOSED ADDITION. 2-ALUMINUM EXTRUSIONS SHALL MEET THE STRENGTH REQUIREMENTS OF ASTM B221 AFTER POWDER COATING. 3-ALL ALUMINUM EXTRUSIONS ARE TO BE A MINIMUM 6063 T6 DESIGN STATEMENT: THE INDICATED SCREEN/GAURD RAILING SYSTEMS USE LOADS FROM SECT 1607.7 OF THE FLORIDA BUILDING CODE 2014-5TH EDITION JOB NO. 1710933 ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 X 2: 2"X2"X0.044" 2 X 2: 2"X2"X0.050" 2 X 3: 2"X3"X0.045" 2 X 4: 2"X4"X0.050" 2 X 5: 2"X5"X0.050" OPEN BACK SECTIONS 1 X 2: 1 "X2"X0.044" 1 X 3: 1 "X3"X0.045" SNAP SECTIONS 2 X 4 SNAP: 2"X4"X0.045" 2 X 4H SNAP: 2"X4"X0.060" 2 X 5 SNAP: 2"X5"X0.055" SELF MATING (SMB) 2 X 4 SMB: 2"X4"X0.044"X0.100" 2 X 5 SMB: 2"X5"X0.050"X0.116" 2 X 6 SMB: 2"X6"X0.050"X0.120" 2 X 6H SMB: 2"X6"X0.072"X0.224" 2 X 7 SMB: 2"X7"X0.055"X0.120" 2 X 7H SMB: 2"X7"X0.072"X0.224" 2 X 8 SMB: 2"X8"X0.072"X0.224" 2 X 8H SMB: 2"X8"X0.082"X0.306" 2 X 9 SMB: 2"X9"X0.072"X0.224" 2 X 9H SMB: 2"X9"X0.082"X0.306" 2 X 10 SMB: 2"X10"X0.092"X0.374" CHANNELS 1.5"x2.125"x 1.5"x. 045 2"x3.125"x2"x.045 DETAIL A REVIEWED POR CO©€ COMPLIANCE PLANS EXAMINER 15-'11`IZ— DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER. REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE 4) #10 X 1.5" SMS INTO SCREW BO: INTERNAL) N PURLIN, GIRT HEADER OR SILL 1 x2 2x4 SMB 1 x2 1x2 2x4 SMB 1 x2 EXIST. ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL W/ (4) #10 X .75" INTO GIRT OR PURLIN AND (2) # 14 X .75" INTO BEAM OR UPRIGHT 0.062 ANGLE CLIPS MAY BE USED EXISTING PRE CAST ON/i •N HD — 1 x2 X 1 x2 x X X . dg" _ o Cn Cn Cn cc x Q 1 x2 1 x2 2x2 22 KNEEWALL EXIST. EIPS T P. },* T U m HD L E 4'-61/2" HD GLE i HD GLE INSTALLATION NOTES: 1-FASTEN PERIMETER TO WD FRAMING W'1/4"X2-1/2" GALV LAG BOLTS 24" O/C AND WITHIN 6" OF INTERSECTING MEMBERS AND JOINTS. 2-FASTEN PERIMETER TO MASONRY W1/4" X 2-1/4" TAPCON 24" O/C AND WITHIN 6" OF INTERSECTING MEMBERS AND JOINTS. w w w_ gUILO,yC w UPRIGMATMATING OR HOLLO SANFORpSELF O w w AgRTME Nx 1 7 - 1 2 6 6. GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS DETAIL C VARIES SEE PLAN Varies -See plan VARIES SEE PLAN 14'-1 " EXISTING TILED WIDTH VARIES) SCREEN WALL 4'-61/2" 4'-61/2" 14'-1" COMMON WALKWAY TOP) ASSEMBLY NOTES: 1-FASTEN PERIMETER MEMBERS AT CORNERS (INTERNAL) W/(2) 10 X 1-1/2" SMS INTO SCREW BOSSES 2-FASTEN CHAIR RAIL (INTERNAL) TO PERIMETER W/(4) #10X1-1/2" SMS INTO SCREW BOSS OF CHAIR RAIL. ALTERNATELY DETAIL C. F------ CHAIR RAIL SEE INSTALLATION NOTES FOR ANCHORAGE FIG 1 PERIMETER (BASE) NTS SHT. 1 0L) U z 0U m 0 Nco o i- co r zzQo a U of of U J_ W Q Q Lo LL rZ M V ZQO Q2 Q 0 2 U c Oro/' J 0 LL U z 0 Z_ 0 U) w Q H U) z U) U) U) w 00 U w 0 Ira J m w J O J LL o 0U)oW 0,° 3: 1- nLoZz ON- MUUB1T OB 0 01Mff 46 OF 7 MODEL F rn L c. c o ot4 Q W o a d 0 w V GRAPHIC SCALE IN Fr ) i inch = 10 fL GATEWAY AT RIVERWALK PHAS£ T A CONDO.NIINILLM FIRST AMENDMENT LOCATED IN SEC77ON 25, TOWNSHIP 29 SOUTH, RANGE 30 EAST CITY OF SANFORD SEMINOLE COUNTY, FLORIDA UNIT "1408" crz UNIT "1406" UNIT PLAN "F' Square Footage Total: 1,885 sF N0777CE. THIS DRAWING fS AN AS -BUILT OF THE CONSTRUCTED UNIT BASED UPON DRAWINCS PREPARED BY CUHACI & PETERSON ARCHITECTS FOR PROJECT 1202244.1, DIMENSIONS SHOWN HEREON ARE IN DECIMAL FEET PLEASE NOTE_ SOU4RE FOOTAGE TOTALS ARE BASED THE UPON PRE -CONSTRUCTION ARCHITECHTUAL PLANS OVERALL UNIT DIMENSIONS. 0 REQUIRED INSPECTION SEQUENCE BP# 'I - ( Z6 r BUILDING PERMIT Min Max >Ins ection Descri ti®n Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Prepour, . Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building (Other) Address: 907< w. JL LECTRICALL P,EIRbDIT Min Max 1lns ection Descri tion Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final r .r*pc[MT sA(i,='f'+f:'t•y'"• i rz;?9 HFB'i TF,§T-.Y Yh^C N LFY 4tz v y"Wi I`.-' llns action Descri tionll[in Max Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final MECIIANJCA.L 1 E-.K-0 I Min 1D!llx 1lns ection Descri tion Mechanical Rough Mechanical Final min I Max Gas Unde Gas Roug Gas Final REVISED: June 2014