Loading...
HomeMy WebLinkAbout618 Sarita St 17-1299; WINDOWSv to24-D FEIE. q MAY - 4 20V CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: 1 Documented Construction Value: $ -/ (G 50 Job Address: 618 SARITA STREET SANFORD, FL 32773 Historic District: Yes No Parcel ID: 01-20-30-504-0900-0170 Residential Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: Plan Review Contact Person: MARISOL MOJICA Title: ASST Phone: 407-261-2277 Name MINDY MATTHEWS Street: 618 SARITA STREET City, State Zip: SANFORD, FL 32773 Fax: 407-261-2277 Email' MARISOLMOJICA@NEWSOUTHWINDOW.COM Property Owner Information Phone: 407-322-8888 Resident of property? : YES Contractor Information Name Samuel Ochstein CRC #1330822 Phone: Street: NewSouth Window Solutions Inc Fax: 820 E. Altamonte Dr. Altamonte Springs, FL 32701 Phone: 407-261-2277 - Fax 407-261-2278 City, State Zip: _ marisolmojica@newsouthwindow.com State License No.: Information Name: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has 0 commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction O in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 511 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application X` Y x NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713 The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance Lith all applicable laws regulating construction and zoning. renatum of Own /Agent Date I Signature of Contractor/Agent Date r l<n Print OxNmer/A Name Signature of Nota ; -State Date FYPq,;.,+ GAmm'Os onOJFF 976 440 2020XplteStriarChFaminsuancea'385'1019dendedThruTroy O n is Personally K n t or Produced ID V Type of I ^ ^ n lam ` Print Contractor/ a rs Name ignal . 43?f3Gi Date a s MARISOL MOJ Commission # FF 976440 Expires March 29, 2020 BondedThruTroyFa in Insurance BM-385-7019 Contractor/Agent is Personally nown to Me Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical , Mechanical 0 Plumbing[] Gas[] Roof Construction Type: Occupancy Use: Flood Zone: _ Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps, of Stories: Plumbing - # of Fixtures. Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: COMMENTS: ENGINEERING: UTILITIES: FIRE: WASTE WATER: BUILDING: Revised: June30, 2015 Permit Application x NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713 The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance Lith all applicable laws regulating construction and zoning. renatum of Own /Agent Date I Signature of Contractor/Agent Date r l<n Print OxNmer/A Name Signature of Nota ; -State Date FYPq,;.,+ GAmm'Os onOJFF 976 440 2020XplteStriarChFaminsuancea'385'1019dendedThruTroy O n is Personally K n t or Produced ID V Type of I ^ ^ n lam ` Print Contractor/ a rs Name ignal . 43?f3Gi Date a s MARISOL MOJ Commission # FF 976440 Expires March 29, 2020 BondedThruTroyFa in Insurance BM-385-7019 Contractor/Agent is Personally nown to Me Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical , Mechanical 0 Plumbing[] Gas[] Roof Construction Type: Occupancy Use: Flood Zone: _ Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps, of Stories: Plumbing - # of Fixtures. Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: COMMENTS: ENGINEERING: UTILITIES: FIRE: WASTE WATER: BUILDING: Revised: June30, 2015 Permit Application REQUIRED INSPECTION SEQUENCE BP# t -7 - 1 BUILDING PERMIT Minn Mays ion Deseri Lion Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Prepour, . Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drvwall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building (Other) Address: /-- I4- Cno,—, A ELECT.RICA"L -ERMIT Min Max Ins ection Descri $ion Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final Min Mays Inspection IDescri Lion Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final MECHANICAL :- Plt.3MIT Min Max -Inns ection Descri i®n Mechanical Rough Mechanical Final Finn Max Inns ectionn Descn-i fioIIn Gas Underground Gas Rough Gas Final REVISED: June 2014 NeV ill 820 East Altamonte Dr. RNe 407-261-227-1 WIN OWSOLUTIONS www.NewE Made in the South for the South. Date / - To / E-mail t1 1L-__, e , ._...... Home Phone City State I Zip Z..?-! L >_ Business (Mr. / Mrs.) ._ Replacement Windows • Entry & Patio Doors - Storm Doors . Impact Resistant'v WHOLESALE & RETAIL WINDOW CONTRACT NewSouth' Window Solutions actrees to measure, manufacture or furnish and service the folio -inn cust— —ie - s Springs, FL 32701 2278 fax Phone 7 JZ Z Ff St Doors pu sI,." —, to oavrv: All NewSouth Vantage Series Windows include Double Pane, LoE glass with Argon gas, and 17 point fusion welded corners_. qil eVant'ge windows are Sashlite - sealed and vacuum tested with a foam enhanced sash and frame. C* tPatm twhoiewinaaw WtIRe 07— $rm44nSt:4 L4N f teriar only) 0... .... tWatorctlitti..Owhili• 1 n *'Cob,s may vsry slighly fromssmpl< - (Initul} iwnt, m cnlo,) QUANTITY_ OBSCURE GLASS gYES NO LOCATION:_ bA_I L _ ovANTrrr PVC COIL TRIM Wn) gl1Y GPoO54 cRns COLORe_ TEMPERED GLASS '.YES CATION:-- k—r4^ _ONO WftNgfr emusGWns B. snEVantage Tanta tyantage DOUBLE HUNG VANTAGE SERIES EIAtFsC. REENr ` CASEMENT FULL SCREEN) 1t YY U O FUII:SCreen I r, i^ t G 1* 4E 5LIDERVANTAGE SERIES HALI SCREEra e s il i '- i s DOUBLE CASEMENT I ( TWO FULL SCREENS) El Full Screen pp wt y WINDOW VANTAGE SERIES NOSCREEN) i 1 DOUBLE CASEMENT WITH FIXED CENTER f 3 LITE SLIDER PICTURE WINDOW 1 VANTAGESERIES-_---' TWOSCREENS) 6 AWNING & HOPPER TILT YJINDOW i (FULL SCREEN) cab, option of White or Tanonly. PICTURE WINDOW WITH DOUBLE HUNGS VANTAGE SERIES al (TWONALrSCREENS). PATIO DOORS 5/0-A 8/6 (59 1!2"g 79 1/2'"). o sro xtJ6 (71 1l2- x 791t2l I' 1 Indicate the 0,610 X ate (71 I7Y x 96 1/2-) i direction of slide Agee. X6J6I95 t!2"x791@"1. 0hX0 Or OX, D 970 X 676 (107172- X 79 112-) R OHALF SHAPED WINDOWS ( NOT FOAM ENHANCED) ROUNt1 0EYEBROW T OTRAP 11CIIEIEN DRAY! INSPACE) GRID STYLES 44 STANDARD `CONTOUR BRASS/GOLD/PENCIL was this home built prior to 19787)4Yes O No ' Prairie i -- Open Prairie I L ' If yes, the undersigned agress .the terms and condlt{oitsofthe NewSou L d.Safe Work Prachcs dendum_ NUMBER OFWINDOWS TO OTHER: 07HER: L/.: _ LS _4-f 0 Customer agrees to allow NewSouth to dis la a and si/n until 30 da s a com ietion. 0' Ffl ( NO S BUYER'S RIGHT TO CANCEL Total price* BUYER MAY CANCELTHIS CONTRACT BY DELIVERING WRITTEN NOTICE TO T,H6 SELLER AT ANY TIME PRIOR TO MIDNIGHT OF THE TAD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION. BUYER MAY t Down payment $ USE THIS CONTRACT AS THAT NOTICE BY WRITING' i HEREBY CANCEL" AT THE BOTTOM AND ADDING BUYER'S NAME AND ADDRESS. THE NOTICE MUST BE DELIVERED TOTHE SELLER ATTHE ADDRESS SHOWN Balance payable on Balance payable on4 $ Sd ABOVE. U Bank Financing s; jkash on Completion All material is guaranteed to be as specified. All work is to be completed in a workmanlike manner contract is valid only with proper signatures. NewSouth shall not be held responsible for time and other matters beyond its control. Owner agrees that the equity in this property is security for this cc ordergoods, it is not subject to cancellation except as stated above. Start installation approximate promises can cause misunderstandinglinc reforethiscontractconstitutestheentireunderstanding collateral, verbal or otherwise, shall bding, unless signed by both parties. Newsouthtoremosale anctdisc ntsallotted.Alichaludedabove. Thank you for your Ord Q — x , `f u' x l( B yer' s Signatu l NewScr6th Representatil x Buyer'sSignature NewSouth Manufacturin ing to standards and practices. This it delays,. strikes, acts of God or any Si a this contract calls for made to weeks from above date. Verbal tattles; and no other understanding haul away all job related debris. Ali'U 40' orized Officer DocuSign Envelope ID: FA85146B-3752-4468-8E45-0F446D787F84 g h 82Amewsg.lm 0 Altamonte Drive a Altamonte Springs, FL 32701 Oak M go Phone (407) 261-2277 • Fax (407) 261-2278 www.newsouthwindow.com WINDOW SOWTIONS I-W Replacement Windows a Entry & Patio Doors WHOLESALE & RETAIL CONTRACT X ADDENDUM TO ORIGINAL CONTRACT DATED: 7 n To City State Zip Code J1- 7-) Z- Date ' 7 % E-mail i 1 S N b Q c o!. {Y I- D A Home Phone Celk 07g2.1. ,QW Business Phone ( . NEW SOUTH WINDOW SOUTIONS OF ORLANDO, INC. AGREES TO MEASURE, MANUFACTURE OR FURNISH AND SERVICE THE FO Lg9jNG CUSTOM MADE PROCUCTS FOR THE AMOUNT STIPU TED B%W: LO w/Js 11/izi -- JI i/ 0 -S /11 i /T)/f/i%e 1411 /J/Y i/.2 '11 AH/ni A1A, J_S' ..i,// ti. .--v4.41.41ve- , 90eu/i/i L]i/da . 6l/.1•_ i%,., /Gl/,.'L J.'NDetJ.s — A %S k1_ X f ) Nagrids 3rp w 1 ,fw s , BD. z, o -o I i d iD s i Obi tolAdlW 1 oo•^ Two Years Free In Home Service Was this home bullt prior to 1978? YES NO ff yes, the undersigned agrees to the terms and condltians of the NewSouth Window Solutions of 0dando, Ina Lead Safe Work Pfacfrses Addendum BUYER' S RIGHT TO CANCEL ' BUYER MAY CANCEL THIS CONTRACT BY DELIVERING Total price for above $47, WRITTEN NOTICE TO THE SELLER AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER -- THE DATE OF THIS TRANSACTION, BUYER MAY USE Down Payment $ THIS CONTRACT AS THAT NOTICE BY WRITING "I HEREBY CANCEL" AT THE BOTTOM AND ADDING Balance payable on BUYER' S NAME AND ADDRESS. THE NOTICE MUST BE Installation/Delivery $ 7= DELIVERED TO THE SELLER AT THE ADDRESS SHOWN ABOVE. Bank Financing Cash on Completion All material Is guaranteed to be as specified. Ali work Is to be completed in a workmanlike manner according to standard practices. This contract is valid only with Proper sigriatursa. Now South Window Solutions of Orlando. Inc. shall not be held responsible for time and material delays, strikes, acts of Cod or any other matters beyond Its control. Owner agrees that the equity In this property Is securitylor tiNs contract 4nee this contract calls for made to order goods, it is not subject to cancellation except as stated above. Start installation approximately k• weeks fr*n above date. Verbal promises can cause misunderstandings, therefore this contract constitutes the entire understanding of the parties, and no other understanding, collateral, verbal or otherwise, shalt be binding, unless signed by both parties. New South Window Solutions or Orlando, Inc. to remove and haul away all job related debris. All sales and discounts allotted. All charges Included above, Thank you for your arder. X oocusiynee by: 4/ 2 %/2017 Mtos C ;,:), -,,z ILA"' 0W4g314e4ED.., New South Window Solutions of Orlando, Inc. Representative Buyer' s Signature Now South window solutions of oMrMo. Ina. 2011 New South Window Solutions of Orlando, Inc. Authorized Officer aE11I1%10LE_ COUITrY THIS INSTRUMENT PREPARED BY: ,:L,EE;;i'' OF C: ],F;t_ IJ1 ( t_ QIJF,; & C:1_MP ((0L.1_.F; Name: BRIDGET LAMBERTON Address: 820E.ALTAMONTEDR 1-1° % ;?!lei 1'_r 3':L Ar TAMONE SPRINGS EL 32701 CLERK'S v 2017043980 hE=C:01;[)EI;" 05fO4,'2):I: r 1:11 `r F'11 NOTICE OF COMMENCEMENT RL_C:ORDED BY .ieckenrta State of Florida County of Seminole Permit Number: Parcel ID Number: 0 1 -20-30-504-0900-0170 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) LOT 17 BLK 9 DREAMWOLD PB 3 PG 90 DESCRIPTION OF IMPROVEMENT; OWNER INFORMATION: Name: MINDY MATTHEWS Address: 618 SARITA STREET SANFORD, FL 32773 Fee Simple Title Holder (if other than owner) Address: CONTRACTOR: Name: NEW SOUTH WINDOW CRC 1330822 Address: 820 E ALTAMONTE DR ALTAMONTE SPRINGS, FL 32701 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: Addre: In addition to himself, Owner Designates of To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RE36 RDING YOUR NOTICE OF COMMENCEMENT. Un En III of perjury, I decl a hat I have re d the foregoing and that the facts stated in it are true toof y kn C Idlge a d e ief. O er S nature er's Printed Name Florida Statute 713.13 )(g): "The owner must sign the notice of commencement and no one else maybe permitted to sign in his or her stead' State of County of The foregoing instrument was a knowledged before me this day of PO by y L 1 i -.Who is personally known to me Name`of person making statemQnproduced: ORwhohasproducedidentificationtypeofidentificationAA T T Commi55ion4rFF9t6 0 Expires March 29, 20?0 7 ' Notary Signal i3onrledThruSroyFainlnnu ante 300 3fl5- r, ry,.., J` u I'-• ¢ CJ a aC'— -,z C: 1 U Zvi F.. T U f -D 0. " CD O Ucz.w pC) 0CD cL1 W JZ uJ r UL ¢ j m 9 7-,-,\-jNewSUAE&uth WINDOWSOLUTIONS To Whom It May Concern: 820 E. Altamonte Springs Dr. Altamonte Springs, FI 32701 Phone: (407) 261-2277 Fax: (407) 261-2278 Contact Email: hol lyholmberg@newsouthwindow.com I, Samuel Eli Ochstein, hereby authorize the following named person (s) to sign, apply for and purchase permits and/or licenses for New South Window Solutions of Orlando. This list is to replace all others previously issued, which are now to be considered null and void. TYLER LEE FRED BROWN JUSTIN SHAW TIM NAGLE Job Address: 618 SARITA ST SANFORD FL 32773 Sincerely, Samuel Eli Ochstein CRC1330822 State of Florida, County of SEMINOLE Sworn to and subscribed before me, this 1ST day of MAY, 2017, by Samuel Eli Ochstein, who is personally nown to m nd did not take an oath. Marisol Mojic Notary Public fB'` . Commission#FF976440 MARISOLMOJICA State of Florida Y;;'' cdF g• Expires March 29, 2020 Bonded ThruTroy Fain insurance Boo -385-7019 Expires: March 29, 2020 Property Record Card tatmsan,CiA Parcel: 0'-20-30-50^-0900-0170 ---------------------------- __---- Owner. f.4ATTHEWS MWDY ssnx..rcouvrv, ra.orx:odx , Property Address: 6' 9 SARITA ST SANFORD FL 32773-5037 Parcel Information Value Summary Parcel ; 01-20-30-504-0900-0170 2017 Working 2016 Certified I ,Values Values I , Owner! MATTHEWS MINDY— I I Valuation Method CostlMarket Cost/Market I Property Address : 618 SARITA ST SANFORD, FL 32773-5037 1 1 Number of Buildings 1 1 Mailing 618 SARITA ST SANFORD, FL 32773-5037 Depreciated Bldg Value $65,282 $58,611 Subdivision Name DREAMWOLD Depreciated EXFT Value $6,546 $6,546 Tax District . S1-SANFORD Land Value (Market) $12,000 $12,000 DOR Use Code 01-SINGLE FAMILY ; Land value Ag Exemptions ; 00-HOMESTEAD(1994) d_ JusllMarket Value " $83.828 $77,157 7j r`e t I i Seminole County GIs 1 PortabilityAdj Save Our Homes Adj $14.071 $8.835 i Amendment 1 Adj i P&G Adj $0 $0 Assessed Value $69,757 $68,322 Tax Amount without SOH: $733.00 2016 Tax Bill Arnow$640.00 Tax Estimator Save Our Homes Savings: $93.00 TRIM Notice Helt2 Does NOT INCLUDE Non Ad Valorem Assessments Legal Description LOT 17 BLK 9 DREAMWOLD PB 3 PG 90 Taxes Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund - _-- 69,757 44,757 25,000 I Schools 69,757 25,000 44,757 City Sanford 69.757 44,757 25,000 i SJWM( Saint Johns Water Management) 69,757 44,757 f 25, 000 + County Bonds — 69,757 44.757 i+ 25, 000 Sales Description Date Book Page Amount Qualified Vac(Imp WARRANTY DEED i 12/ 1/1990 02251 1953 72,000 Yes Improved I j WARRANTY DEED 11/1/1987 01909 0522 70,500 Yes improved WARRANTY DEED 1/1/1977 01118 0141 3,500 No Vacant I r_.,, rl Comparable 5:!cs Land Method Frontage Depth - Units Units Price Land Value— LOT 0,00 0.00 1 12.000.00 12,000 Building Information Is Bed/Bath Count tncprrecl? Click Herc. x--- Year Built DescriptionFixtures Bed i Bath Base Area Total SF Living SF Ext Wall Adj Value ; Repl Value t Appendages IActual/Effective I RILW.Sq0th 50W110EMli Window Specification and Detail Pursuant to Contract with NewSouth Wind Solutions Customer: i4—f--A v6;K, 4 Notes: Address. --Y City: SlJ Jf Ort -:;ez- — Zip: 32 -77r- Phone: (H) (C) Q-7 3Z Z 9 F rf (W) Z J Back Wx, a;, 1 t r WA 3 No h 1, ' IZ First Floor l Installation Notes: YJiAdlj C 11ir/9G S i o Contract Date. - 7 Factor T.: AI-Y /<. Frames,. Screens Insulated Glass Unit Grid Options Customer Approval. g x i Glass E ! Type i, m 3 o o v o m I o o c 1 3' Color W x H) (W x H) 1 W x H) WIN Location Style EXTlINT Sales Measure Opening Size Make Size 9 Additional Information S r rJ w._.. 3L x a x ' x ti I DAD S' O>G 2 Q s x a2 1 x a' y x 0 Y t X i i qyeo y 0 x 4 3 7 X s ;_. X— x yea+ X X I 5 DI 37 x St ix x yy QTer/ 2-7 x ,-5. l X------i•` 4 x yp I 6 C' 1 I l_ x 3 L x 3 G! x x x x X14, 1012 j 3- 4_x_ x y x a 1/ 13 0 :_. 0 x x i x 4 SIsy I/ t? 4 x 15 x x a$ / f h 16 x x 17 i x x_ x_ x S ANF 16 x _ x x A PFAhAIT S& IE&TRUED 19 O1. x x x LI N T PR CE TO BE A b z x xREN! Eb COD q VI E, CANCEL, ALTEROR SFT PLANS EXAMINER A- 1 --- DATE 0 l, vut5, NOR SHALL ISSUANCE OF A PERMIT PREVENT THEBUILDINGOFFICIALFROMTHEREAFTERREQUIRINGACORRECTIONOFERRORSINPLANS, CONSTRUCTIONORVIOLATIONSOFTHISCODE City of Sanford Building and Fire Prevention Product Approval Specification Form Permit # Project Location Address As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Sliding Sectional Roll U Automatic Other 2. Windows Single Hun Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other rI June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # including decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 W, Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature OK Applicant's Name Please Print) June 2014 2/18/2016 Roilda Departneflt-cf aCIS Home Log In User Registration + Hot Topics Busines Product Approval4USER: Professi nal Public User Regulation Florida Building Code Online Submit Surcharge Stats 6 Facts Publications FBC Staff aCIS Site Map I Links search i R!1 ,1nt,!ITTIf". Product Aooroval Menu > Product or Aouhcaoon Search > AppOcat 0n 05 > Application Detail FL Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated FL15378-R2 Revision 2014 Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. NewSouth Window Solutions 4901 oak fair blvd tampa, FL 33610 513) 284-0129 danochstein@newsouthwindow.com Vivian Wright rickw@rwbldgconsultants.com Windows Double Hung Certification Mark or Listing National Accreditation & Management Institute Ryan 1. King, P.E. Validation Checklist - Hardcopy Received Standard Year AAMA/WDMA/CSA101/l.S.2/A440 2008 AAMA/WDMA/CSA101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2005 Method 1 Option A 09/30/2015 09/30/2015 https:ltwww.tloridabuilding.orgfprlpr_app dtl.aspx?param=wGEVXQwtDgIH8572gvdWieHZ%2bkKh%2bFD75TJrcbOlUmjBO71jfaxSWA%3d%3d 1/3 2/18/2016 Florida Building Code Online Date Pending FBC Approval Date Approved 10/01/2015 Summary of Products FL !_ i Model, Number or Name i Description 15378.1 _ i a. DuraGard Double Hung Window DuraGard New Construction (Nail Fin) "Non -Impact" Vinyl Double Hung Window (X/X - configuration; Max Size 54 x 75) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15378 R2 C CAC NAM] Cert for 15378.1 (54 x 75).Ddf iApproved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date I Impact Resistant: No 12/31/2019 Design Pressure: N/A I' Installation Instructions Other: See INST 15378.1 for Design Pressure Ratings, any FL15378 R2 11 INST 15378.1.00 additional use limitations, installation instructions and product I Verified By: Lyndon F. Schmidt, P.E. 43409 particulars. Created by Independent Third Party: Yes Evaluation Reports FL15378 R2 AE EVAL 15378.1.Ddf Created by Independent Third Party: Yes 1 15378.2 b. DuraGard Double Hung Window DuraGard Replacement "Non -Impact" Vinyl Double Hung i1 Window (X/X - configuration; Max Size 54 x 75) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15378 R2 C CAC NAMI Cert for 15378.2 (54 x 75).odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 1.2/31/2019 Design Pressure: N/A Installation Instructions Other: See INST 1S378.2 for Design Pressure Ratings, any FL15378 R2 11 INST 15378.2 Ddf additional use limitations, installation instructions and product! Verified By: Lyndon F. Schmidt, P.E. 43409 particulars. Created by Independent Third Party: Yes 15378.3 Evaluation Reports j FL15378 R2 AE EVAL 15378.2.odf I Created by Independent Third Party: Yest c. Sashlite Double Hung Window Sashlite New Construction (Nail Fin) "Non -impact" Vinyl i Double Hung Window (X/X configuration; Max Size 54 x 75) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No I-LI5376 R2 C CAC NAM] Cert for 15378.3 (40 x 60).Ddf Approved for use outside HVHZ: Yes FL15378 R2 C CAC NAM] Cert For 15378.3 (54 x 75).Ddf Impact Resistant: No ! Quality Assurance Contract Expiration Date Design Pressure: N/A 11/30/2019 Other: See INST 15378.3 for Design Pressure Ratings, any Installation Instructions additional use limitations, installation instructions and product FL15378 R2 it lnst 15378.3.odf particulars. Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15378 R2 AE EVAL 15378.3.odf 1 Created by Independent Third Party: Yes , 15378.4 d. Sashllte Double Hung Window Sashlite Replacement "Non -Impact" Vinyl Double Hung Window (X/X - configuration; Max Size 54 x 75) Limits of Use Certification Agency Certificate _ Approved for use in HVHZ: No FL15378 R2 C CAC NAMI Cert for 15378.4 (48 x 72).Ddf Approved for use outside HVHZ: Yes FL15378 R2 C CAC NAMI Cert for 15378.4 (54 x 63).Ddf Impact Resistant: No i FL15378 R2 C CAC NAMI Cert for 15378.4 (54 x 75),Ddf Design Pressure: N/A ! Quality Assurance Contract Expiration Date iOther: See INST 15378.4 for Design Pressure Ratings, any 03/31/2019 additional use limitations, installation instructions and product Installation Instructions particulars. FL15378 R2 11 INST 1.5378.4.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes j Evaluation Reports IjFI-15378 R7. AE EVAL 15378.4.pdf Created by Independent Third Party: Yes f 15378.5 e. DuraGard Double Hung Window Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15378.5 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. DuraGard New Construction (Nail Fin) "Impact" Vinyl Double 6 Hung Window (X/X - configuration; Max Size 40 x 72) j Certification Agency Certificate FL15378 R2 C CAC NAMI Cert for 15378.5 (40 x 70).Ddf Quality Assurance Contract Expiration Date 12/31/2019 Installation Instructions i FL15378 R2 Il INST 15378.5.odf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15378 R2 AE EVAL 15378.S.odf https://www.floridabuilding.orglprlpr_app_ li.aspx?param=wGEVXQWIDgtH8572gvdWleHZ%2bkKh%2bFD75TJrcbOtUmjBO71jfaxSWA%3d%3d 2/3 2/18/2016 Online Created by Independent Third Party: Yes 15378.6 f. DuraGard Double Hung Window i Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15378.6 for Design Pressure Ratings, any additional use limitations, installation instructions and produ particulars. DuraGard Replacement "Impact" Vinyl Double Hung Window X/X - configuration; Max Size 40 x 72) tion Agency Certificate 1 Quality Assurance Contract Expiration Date 12/31/2019 installation Instructions FL15378 R2 H INST 15378.6.ndf ct Verified By: Lyndon F. Schmidt, P.E. 43409 I Created by Independent Third Party: Yes Evaluation Reports i FL15378 R2 AE EVAL 15378.6.Ddf Created by Independent Third Party: Yes Contact Us :: 1940 North Monroe Street, Tallahassee FL. 32399 Phone: 850-487-1824 The. State of Florida Is an AA/EEO employer, copyright 2007-2013 State of Florida.:: Poyacy Statement ;; Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions. please contact 850.467.1395. -Pursuant to Section 455.275( 1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 4S5, F.S., please click. here . Product Approva l Accepts: Creel httpsllwww.Floridabuilding.orgtprlpr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWIeHZ%a2bkKh%2bFD75TJrcbOtUmjBO71jfaxSWA%3d%3d 313 P]Newhuth WINDOW SOLUTIONS 4901 Oak F&r Blvd., iompa, FL 33610 DuraGard Double Hung Window IMPACT' GENERAL NOTES 1. This product has been evalualed and is in compliance with the 5th Edition 120141 Florida Building Code (FBC) structural requuemenls excluding Ihe'High Velocity Hurricane Zone" HVHZ), See the Certification Agency Certificate for sues. specifications and ratings. 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. when used in areas requiring wind borne debris protection this product complies with Section 16D9.1.2 of the FBC and does not require on impact resistant covering. This product meets missile level'U' and excludes Wind Zoned as defined in ASTM E1996 and Section 16D9.1.2.2 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction. 5. Site conditions thal deviale tram the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS SHEETS I DESCRIPTION 1 Typical elevations. design pressures & general notes 2 1 Vertical & horizontal cross sections 3 Vertical & horizontal Cross sections 4 Buck & frome anchoring 5 Components 6 Bal of materials and glazing deloils aa' MAX. OVERALL -- - FRA1.5E WiDTIFr 1 i X a f X i MAX MAX DESIGN PRESSURE FRAME D.LO. GLASS LPG DIMENSION DIMENSION TYPE POS. NEG. 400X72.0- aa.irx=r Gt 50.0 50.0 r 1. NOTE: AMB REINFORCEMENT CLIP, ITEM 034, LOCATED V ' AT THE BOTTOM SASH TILT LATCH ON EACH JAMB P 'e'• AND SECURED WITH ONE 08 x 2-1/2' PH SMS. II LOCKS 121 T FROM EACH END v n o Z 30 w a oZ C YI 3 J d o 9 ! — a 9 21 22 ^_ o 2 2 3 2 Y m 4f 12 m a 0 G O > D .._.._. f I 00 I I/d' MIN. 8 EVERIOR O 6O INTERIOP, jQ SEE NOTE I EMB. ITrP.I C 12 GT31 F '- / O IMERIOR 29' SG1 O1 0 12 o 32 rr l O B Z uz 1 I p o 12 tql Z U EXTERIOR -'"`_ scuc 1v.T,5. E 3 ` owc. a - JK m cYx. Ln: LFS 2 VERTICAL CROSS SECTION a11HORIZONTALCROSS $EC710N 1 n 2x Buc4 uo=n Cony w:fo 2 2x 8w_t uaeonry CanatrucLMn u2n,y FL-153>8.G n sin or 6 p ssilltl 1111/ ' NOTE \ : •' . * ' NI. JAMB REINFORCEMENT CLIP. ITEM 034, LOCATED \ SEE NOTE I AT THE BOTTOM SASH TILT LATCH ON EACH JAMB+• '• nA ' AND SECURED WITH OTIE 114' X }114' PFH ITY.' = U ' 8 •.. t o O CONCRETE SCREW. <-- t 31 1 GI ': : 3 n n T t"/ INTERIOR o 0. i a / / IN 11111 .. .. 1 m 0 V 0 or=^ E m z a' E u Q o a 4 E oz xw 1 oa 31 o r—FJ.tB.Ii1'P.) / EXTERIOR U( N a O 3 j u 1 HORIZONTAL CROSS SECTION of o o 3 sno n.11X 1 n G1 EXTERIOR. — INTERIOEYTEROOR - -- G1 INTERIOR fS1R5N 32 12 32 cc 12 2 O o y < p o y y Z u a+, c 6/17/15 z0 0 scxc. N.'T.S JK to 2 VERTICAL CROSS SECTION 1 3 VERTICAL CROSS SECTION C.ti W: L-FS Masofwy sin 3 Masor ry sill n FL- 15J78.6 0 xn 3 a 6 p a g .Io 6 a3Hs pOcvA to Bw!!>bs III IuanaM of v..am pOa.+ O Jo Bu(OOQs'O'o.,17'oouolnp pua_I •e vOlslp a6pa,g/S wnwlunu o nolu!ow'I a 9'8LiS1—1,3 :S31ON NOII"YISNI M3b7S000M z - a+ °mxwo Sal ae ' n c OJ73 NOJd VI E( .f7JtUDED VINTt fRRME f 0 Ljl i -- 1.25' -- Z REINFORCEMENT C 0 1.286"--t I OIAMB REINFORCEMENT CUP 1' N"Idp 1.625' j 0 1 lCD v CD 0.0T - KFFIER RAIL OTOP RAIL 2 EXTRUDED VINYL SILL 2.17' 1.03' UF` 1 a C 0.0T O j I - 0.28- OBOTTOM RAIL 0.22' 0.O7 0(W ---I 9 GUZING BEAD 3 EXTRUDED VINYL IAMB 1.625 — T C= D.or -- -- i O N h 0 0.93" -I I. _ d LOCK RAIL 0 %111 tit i ll o m z U N •; a.0 cw 267 G 0 V F o z r• E. 6117115 aC' N. i. S. W; JK a LFS FL- 15378.6 n 5 a$ ttttttttr*urr q i c iLQ p i n 7 o 'Ozy a rrrn nl t t _ z Is z F v Z O 2 V ma 8 r maa G a o= ga T I/T GLASS BITE o Z q 10 7/B' O.A. GLASS tHK. = 118' ht4MFALEO GLASS 2 m t J O.Q9Q'ShfIEX of p`•> u PVBINTER1AYER u O o ©¢ a I/8' ANNEALED GLASS o n a AIR SPACE I/8' ANNEALED GLASS i THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY SUPER SPACEP. (FOAM( EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". n GT GLAZING DETAIL ci G z w 1 CJ j u ate 6/17/15 sg,Lc, N.T.S. ' i ocw. 1* JK m CHK W.- LFS z DFNwING NOS n FL-15378.6 cN JfLEi OF 5 BILL OF MATERIALS rreA DaedrrloN µhrEwu A V X BUCK (SG >= 0.42J WOOD g 2X BUCK (SG>=0.42) WOOD C 1!4" MAX. SHIM SPACE STEEL. p I J4" X 2.3/4" PFH ELCO OR ItW CONCRETE SCREW STEEL. E MASONRY 3.000 PSI MIN. CONCRETE CONFORMING TO ACI 30t OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE F 8 X 2" PFH WS (1-l/2" MIN. EMBEDMENT) STEEL M 1!4" X 2-3/4" HH ELCO OR LPN CONCRETE SCREW STEEL. PVC1HFAO-441F' 2 SILL - 442f' PVC 3 JAMB - 4-03f' PVC 4 TOP RAIL.- 475B' PVC 5 BOTTOM RAIL- 485g' PVC 6 LOCK. RAIL • 49A8' PVC 7 KEEPER RAIL-4938• PVC 8 STILE - 420B' PVC 9 GLAZING BEAD - 4468'' PVC. 10 SILCONE GLAZING SEALANT TREMCO S-%00J T2 RHNFORCEMENT-480C COMP. 21 KEEPER - TRUTH kC41275 22 LOCK ASSEMBLY -TRUTH NA30700401 23 BALANCE 30 CENTER FIN PILE - .187 X .190 31 CENTER FIN PILE • .270 X .220 32 FOAM SEAL - BOTTOM RAIL - AMESBURY k326b3 33 FOAM SEAL -TOP RAIL - AMESBURY R32012 34 JAMB REINFORCEMENT CLIP N970 STEEL I 'k BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search bd 0Product Approval USER: Public Userlo%' r Product Approval Menu > Product or Application Search > Application List > Application Detail s,. € FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL15378-R2 Revision 2014 Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. f NewSouth Window Solutions 4901 oak fair bivd tamps, FL 33610 513) 284-0129 danochstein@newsouthwindowlcom Vivian Wright rickw@rwbldgconsultants.com Windows Double Hung Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By Ryan 1. King, P.E. Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year AAMA/ W DMA/CSA 101/I. S.2/A440 2008 AAMA/WDMA/CSA101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2005 Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Method 1 Option A 09/30/2015 09/30/2015 m Date Pending FBC Approval Date Approved Summary of Products 10/01/2015 II FL Model, Number or Name Description 15378.1 (a. DuraGard Double Hung Window DuraGard New Construction (Nail Fin) "Non -Impact" Vinyl ILA Double Hung Window (X/X - configuration; Max Size 54 x 75) Limits of Use j Certification Agency Certificate Approved for use in HVHZ: No I FL15378 R2 C CAC NAMI Cert for 15378.1 (54 x 75).Ddf Quality Assurance Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 12/31/2019 Design Pressure: N/A Installation Instructions Other: See INST 15378.1 for Design Pressure Ratings, any FL15378 R2 II INST 15378.1.odf additional use limitations, installation instructions and Verified By: Lyndon F. Schmidt, P.E. 43409 product particulars. Created by Independent Third Party: Yes Evaluation Reports FL15378 R2 AE UAL 15378.1.Ddf Created by Independent Third Party: Yes i 15378.2 I b. DuraGard Double Hung Window DuraGard Replacement "Non -Impact" Vinyl Double Hung Window (X/X - configuration; Max Size 54 x 75) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15378 R2 C CAC NAMI Cert for 15378.2 (54 x 75).odf Quality Assurance, Contract Expiration DateApprovedforuseoutsideHVHZ: Yes Impact Resistant: No 12/31/2019 j Design Pressure: N/A Installation Instructions i Other: See INST 15378.2 for Design Pressure Ratings, any I FL15378 R2 II INST 15378.2.odf i additional use limitations, installation instructions and Verified By: Lyndon F. Schmidt, P.E. 43409 product particulars. Created by Independent Third Party: Yes i j Evaluation Reports FL15378 R2 AE EVAL 15378.2.odf i Created by Independent Third Party: Yes 15378.3 ; c. Sashlite Double Hung Window Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15378.3 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. 15378.4 f d. Sashlite Double Hung Window Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15378.4 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. 15378.5 1 e. DuraGard Double Hung Window Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15378.5 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Sashlite New Construction (Nail Fin) "Non -Impact" Vinyl Double Hung Window (X/X - configuration; Max Size 54 x 75) Certification Agency Certificate FL15378 R2 C CAC NAMI Cert for 15378.3 (40 x 60).Ddf FL15378 R2 C CAC NAMI Cert For 15378.3 (54 x 75) Ddf Quality Assurance; Contract Expiration Date 11/30/2019 Installation Instructions FL15378 R2 II Inst 15378.3.Ddf Verified By: Lyndon F Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15378 R2 AE EVAL 15378.3.Ddf Created by Independent Third Party: Yes ite Replacement "Non -Impact' Vinyl Double Hung kw (X/X - configuration; Max Size 54 x 75) Agency Certificate Quality Assurance Contract Expiration Date 03/31f2019 Installation Instructions V rified By: Lyndon F. Schmidt, P.E. 43409 reated by Independent Third Party: Yes Evaluation Reports FL15378 R2 AE EVAL 15378.4.Ddf Created by Independent Third Party: Yes DuraGard New Construction (Nail Fin) "Impact' Vinyl Double Hung Window (X/X configuration; Max Size 40 x 72) Certification Agency Certificate FL15378 R2 C CAC NAMI Cert for 15378.5 (40 x 70).Ddf Quality Assurance Contract Expiration Date 12/31/2019 Installation Instructions FL15378 R2 II INST 15378.5.Ddf Verified By: Lyndon F Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports 1 15378.6 1 It. DuraGard Double Hung Window Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15378.6 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. FL15378 R2 AE EVAL 15378,5,odf Created by Independent Third Party: Yes DuraGard Replacement "Impact' Vinyl Double Hung Window X/X - configuration; Max Size 40 x 72) Certification Agency Certificate FLIS378 R2 C CAC NAM] Cert for 15378.6 (40 x 70).Ddf Quality Assurance Contract Expiration Date 12/31/2019 Installation Instructions FL15378 R2 II INST 15378.6.odf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15378 R2 AE EVAL 15378.6.pdf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer, Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida taw, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions^,please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addre'.sses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to thelpublic. To determine if you are a licensee under Chapter 455, RS., please click here. Product Approval Accepts: Fl_r_r 9 Credit Card Safe Sash ite Double dung Window NON-IMPAcr' GENERAL NOTES 1. This product has been evaluated and is in compliance with the 5th Edition (2014) Flo6do Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" HVHZ). See the Certification Agency Certificate for sizes, specifications and ratings. 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product is required to be protected with on impact resistant covering that complies with Section 1609.1.2 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x b0ck mdsonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS SHEET# DESCRIPTION I Typical elevations, design pressures & general notes 2 Verticat & horizontal cross sections 3 Vertical & horizontal cross sections 4 Buck & frame anchoring 5 Components 6 Bill of materials and glazing details 54" MAX. OVERALL --- FRAME WIDTH X w C! I X i• MAX FRAME DIMENSION MAX D.LO. DIMENSION GLASS45S TYPE DESIGN PRESSURE PSI) POS. NEG. 54.D' X 7S.D" 48.25" X 34.5' GI 20.0 25.0 54.17' X 63.0" 48.2S" X 28.S' GI 30.0 35.0 48.0" x 72.D 42.2Y X 33.IY Gt 30.0 35.0 Z M Z nc m Oz U WE: 6/17/15 a sum N.T:S. DWG. Dr: JK m LFS 3 D WING NO.. FL-1537&4 N 0 SHEET _1 OF 6 N IIIl tlry r P T ` Y'2 2 i o_ J'u LOCKS (2) '/ g2jr4 t o n za T FROM EACH END, m 6 E a c i g `oaO__ F v v 030oz X \ 33 O J aoo q o Z9- 21 z N 14 , J ou222232mau, a B aoa0vo0q ' o 1-1/4"MIN. EXTERIOR -_O INTERIOR o EMB. (TYP.) O K Q t 12 Jm I Q F 31 09 O N 1 INFERIOR z 30 Zo l n _ c l r2 Z C W0 O ^ LJ Z O G1 - 4 O IXTERIOz 1 1are: 611. 15 0 8 R fir; Z oN. T.S. i CHK. BY. LFS ; E oanwuu ru, e 1 HORIZONTAL CROSS SECTION I'2 VERTICAL CROSS SEC77ON Zi FL-15378.4 a 22XBuckMasonryConstruction '1 2X Buck Masonry Construction n y r kiT O INTERIOR % V'•. •,yj; < z n n C 15 o z31QG1ur 9 i ' z cdi m° Q\\ 1 \+Ti`O ooa 0 i DZ ^ , W e z z o2 U wa1-1/4' MIN. 8 EXTERIOR m EMB. (TYP.) n a a 1 HORIZONTAL CROSS SECTION 3 Shawn rith I sub -buck EXTERIOR - 4. - - INTERIOR EXTERIOR 1 5 1 INTERIOR ti z T\ U c R 2.i) C 2 Z a w1E: 6 17 1 s N. r. s. 0 owc. ar: JK m VERTICAL CROSS SECTION ` w O VERTICAL CROSS SECTION H.. LFs % j Masonry sip 3 Masonry sill one n c w FL-15378.4 0 N 2X BU MASONRY OPENING 2X BUCK ANCHORING C TYP.) 2X SUB BUCK FRAM MASONRY OPENING I. Concrete anchor rotations at the comers may be adjusted to maintain the min. edge distance to mortarjoinh. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to mainfoin the min. edge distance to mortarjoinfs, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete onchor:oble: ANCHOR ANCHOR MIN. MIN. CLEARANCE MIN. CLEARANCE TYPE SIZE. EMBEDMENT TO MASONRY TO ADJACENT EDGE ANCHOR ITw 1!4" 1•i/4" 2" 4" TAPCON ELCO a 4" ULTRACON WOOD SCREW INSTALLATION NOTES: Maintain a minimum 518" edge distance. 1' end distance, 6 I' o.c. spacing ofI. dg wood screws to prevent the spirtling of wood. 1. FRAME ANCHORING 2X BUCK E IX SUB BUCK FRAM MASONRY OPENING R" FRAME ANCHORING I X BUCK t4*1 X. 0 o';J:tiri z GriQ Fj.l• Gj` oa a n may m o m Z e V 0 Z_ OZ U 9poa dNa mo:ami I 4 c dEoZ S d 30o w c lz v a s x I w z 0 a w0O Z m m v < a _ rn o i o C z c we N.T.S. c. Br: JK c C ev: LFS rz wINC W.: v FL-15378.4 n 4 or 6 r' EXTRUDED VINYL FRAME 1.06' iIb N 2.1T' 0.1251.47 1 0,245 @REINFORCEMENT b. 000 0 1 LOCK RAIL REINFOCEMENT 4 TOP RAIL 1,565' -- 1 1.45 1 000 0.075" O KEEPER RAIL 8 70P SASH STllf 2 EXTRUDED VINYL SILL 2.17- i U000u n0 0.075" -- 1.42" 5 BOTTOM RAIL a 0.13', --- — 13 REINFORCEMENT EXTRUDED VINYL JAMB o 0.26" — i F-- 9 GLAZING BEAD 15 BOTTOM SASH STILE p• w n 42= J a dm m h pi v U p = zmc 7 • t o o a1a5maam c 4 c oZ gEy a vf j 0.27" --1 4 KEEPER GLAIING BEAD F- IS —j 09 000 _ a i OLOCK RAIL L 6/17/15 oLE: N.T.S. c. e: JK m e•. LFS a 1WIYL NO.: N . FL-15378.4 N ET 5 or 6 m 1111111IT BILL hAv a- U. J4 p3 om 5 6 FO m U H .. O U p ZEazma 0h goga i aa g d E `0 I/2"GIASSBffE ii Ja a 3/4" O.A. GLASS THK. U J o I z 0 AIR SPACE m 4 jIIJJ o I o a1 /8" ANNEALED GLASS x o° 10 O THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED G(AIING DETAILGl W Zo 3 BY EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". n a 3w o 5 Z a n h a O a Z DpuZ u aTE 6117175 3 SCALE: N.T.S. D R i CH.m: LFS ; Q OMWWC ND.: FL- T5378.4 0 f N sHen 6 Dv 6 g OF MATERIALS REM R DESCRIIl10N MATERIAL A I X BUCK SG >= 0.42 WOOD B 2XBUCKSG>=0.42 WOOD C 1/4" MAX. SHIM SPACE STEEL D 1/4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE F 8 X 7' PFH WS (i-1 /2" MIN. EMBEDMENT) STEEL P I /4" X 2-3l4" HH ELCO OR ITW CONCRETE SCREW STEEL I HEAD-441F' PVC 2 SILL-442F' PVC 4... 41 4rnai'3: vaaj d3 a# A .: BCIS Home Log In User Registration i Hot Topic Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links i Search bd-. riUji-M., Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL16842-R3 4' ry Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer New South Window Solutions Address/Phone/Email 4901 oak fair blvd tampa, FL 33610 513) 284-0129 danochstein@newsouthwindow,com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2017 Validated By Ryan 1. King, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL16842 R3 COI CERTIFICATE`OF INDEPENDENCE cc.odf Referenced Standard and Year (of Standard) Standard Year AAMA/ W DMA/CSA 101/I. S.2/A440 2008 AAMA/ W DMA/CSA 101/I. S. 2/A440 2005 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2005 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I Option D Date Submitted 12/20/2015 Date Validated 01/14/2016 Date Pending FBC Approval 01/18/2016 Date Approved 04/12/2016 Summary of Products Go to Page O Page l/2010 FL # Model, Number or Name Description 1684 2 1 a. 9500 Slider XO Extruded Vinyl "Non -Impact" Horizontal Sliding Window j utilizing a Nail Fin Installation (XO or OX configurations) j Limits of Use i Installation Instructions Approved for use in HVHZ: No FL16842 R3 II Inst 16842.1.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.1 for Design Pressure Ratings, any 116842 R3 AE Eval 16842.1,odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16842.2 i b. 9500 Slider XO Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XO or OX configurations) Limits of Use I Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16842.2.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.2 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.2.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. i 116842.3 j c, 9550 Slider XO - Impact Rated I Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XO or OX configurations) I Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II Inst 16842.3.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.3 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.3.odf IIII I additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16842.4 i d. 9550 Slider XO - Impact Rated Extruded Vinyl "Impact' Horizontal Sliding Window with I Flange Installation (XO or OX configurations) j Limits of Use Installation Instructions Approved for use In HVHZ: No FL16842 R3 II Inst 16842.4.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports j Other: See INST 16842.4 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.4.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16842.5 e. 9550 Slider XO - Impact Rated - Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a i HVHZ Nail Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R3 II Inst 16842.5.odf jj Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 1 Impact Resistant: Ves'"' '""' - - Created by Independent Third Party: Yes Design Pressure: N/A "- Evaluation Reports Other: See-INST_16842.5-for-Design-Pressure-Ratings, any -- additional use limitations, installation instructions and — FL16842 R3 AE Eva] 16842.5.odf i l Created by Independent Third Party: Yes product particulars. 16842.6 j f. 9550 Slider XO - Impact Rated - Extruded Vinyl "Impact" Horizontal Sliding Window with HVHZ Flange. Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes I Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 f Impact Resistant: Yes Created by Independent Third Party: Yes f Design Pressure: N/A Evaluation Reports Other: See INST 16842.6 for Design Pressure Ratings, any FL16842 R3 AE E'val 16842.6.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. j 16842.7 i g. 9500-3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II Inst 16842.7.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.7 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.7.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16842.8 h. 9500-3 Slider XOX Extruded Vinyl "Non -Impact' Horizontal Sliding Window with f Flange Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II Inst 16842.8.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 iImpactResistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.8 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.8.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16842.9 11. 9550-3 Slider XOX - Impact Rated Extruded Vinyl "Impact' Horizontal Sliding Window utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions f Approved for use in HVHZ: No FL16842 R3 II Inst 16842.9.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.9 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.9.odf additional use limitations, Installation Instructions and Created by Independent Third Party: Yes j product particulars. i 16842.10 j. 9550-3 Slider XOX - Impact Rated Extruded Vinyl "Impact' Horizontal Sliding Window with Flange Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II Inst 16842.10.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure., N/A Evaluation Reports Other: See INST 16842.10 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.10,odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16842.11 k. 9550-3 Slider XOX - Impact I Extruded Vinyl "Impact' Horizontal Sliding Window utilizing a Rated - HVHZ Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use In HVHZ: Yes I FL16842 R3 II Inst 16842.11.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.11 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.11.0df additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. I 16842.12 11. 9550-3 Slider XOX - Impact Rated I Extruded Vinyl "Impact' Horizontal Sliding Window with HVHZ Flange Installation ,(XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R3 II Inst 16842.12.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.12 for Design Pressure Ratings, any FL16642 R3 AE Eval 16842.12.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16842.13 im. DuraGard Slider XX Extruded Vinyl "Non -Impact' Horizontal Sliding Window utilizing a Nail Fin Installation (XX, configuration) Limits of Use I Installation Instructions ennrnved fnr n in NV147- Nn FL16842 R3 Il INST16842.13.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.13 for Design Pressure Ratings, any FL16842 R3 AE Eyal 16842.13.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. i 16842.14 1 n. DuraGard Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XX, I configuration) 1 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16842.14.1)df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports j Other: See INST 16842.14 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.14.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16842.15 ; o. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16842.15.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.15 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.15.odf j additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16842.16 1 p. DuraGard - 3 Slider XOX ( Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 Il INST 16842.16.odf ! Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, RE, 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.16 for Design Pressure Ratings, any FL16842 R3 AE Eva[ 16842.16.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16842.17 ; q. Sashlite Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16842.17,odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.17 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.17.odf j additional use limitations, installation instructions and Created by Independent Third Party: Yes I product particulars. 1 16842.18 1 r. Sashlite Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16842.18,Ddf j Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes i Design Pressure- N/A Evaluation Reports Other: See INST 16842.18 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.18.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 16842.19 1 s. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions ! Approved for use in HVHZ: No FL16842 R3 II INST 16842.19.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 161142,19 for Design Pressure Ratings, any I FL16842 R3 AE Eva] 16842.19.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes 1 product particulars. I ' 16842.20 I t. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XOX, I configuration) Limits of Use j Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16842 20 Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 I Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A I Evaluation Reports Other: See INST 16842.20 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.20.odf additional use limitations, installation instructions and ; Created by Independent Third Party: Yes product particulars. Go to Page Page 1 / 2 Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone:-+BSD-487.1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any question,; please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: a] Fwialll tLgx_t 'ff Credit Card Safe INewsouthWINDOW -SOLUTIONS 4901 Oak Fair Blvd., Tampa, FL 33610 9550 Slider XO IMPACT RATED - HVHZ w/ Flange GENERAL NOTES I . 1 his product anchoring drawing has been evaluated and is in compliance with the 51h Edition W14) Florida Building Code lFBC) including the "High Velocity Hurricane Zone" {HVHZ). See the Certification Agency Certificate for saes, specifications & ratings. 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ, this product complies with Section 1626 of the FBC and does not require on impact resistant covering. 4. For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS SHEEN DESCRIPTION I Typical elevations. design pressures & general notes 2 Vertical & horizontal cross sections 3 Buck & frame onchoring 4 Components 5 Bill of materials and glazing details 75, MAX. OVERALL FLANGE WIDTFI — -- 74" MAX. OVERALL FRAME WIDTH -- I Z O iii MAX. OVERALL MAX. OVERALL MAX MAX DESIGN PRESSURE FLANGE FRAME DAY LITE DAY LITE GLASS SDIMENSIONDIMENSIONTYPE DIMENSION DIMENSION OPERABLE) FIXED) POS. NEG. 75.LY X 64.V' 74.0" X 63.0' 33.5 X 57.31' 33.2S' X 58.54" G1, G2 55.0 60.0 Note: this product, when used with G I glaring, is not approved for use above 30 feet in the "HVHZ" E 2119114 LEN.T.S. El: JK m v FL- 16842.b Er I of 5 P 2 I 2 11 I Note: I. Lock and keeper located T from each end of lock/meeting stile. 2. Metal rofter assembly located Z' from each end of the bottom roil. 3. Anti -lift secured to head with 6) tf 6 x 112 " PPH SMS. I.1IA. RAIN v 1 HORIZONTAL CROSS SECTION Q 2X Buck Masonry Construction NOTE: Sheet Metal Screws must penetrate a min, of 3 threads through at least 2 sheets of metal. 4 HORIZONTAL CROSS SECTION 2 Metal Stud Construction I.114" MIN. EMB. (TYP.) 2 HORIZONTAL CROSS SECTION Q I X Buck Masonry Constriction i f a 1 VERTICAL CROSS SECTION w 2 2X Buck Masonry Construction _ ICI WE 2 19 14 SCALE N. T. S. o-G. BY: JK CHK. SY: LFS oR *ING w, FL— 16842. o" SNrET 2 or 5 u u C kl: N s n V• Z •t''` 00 et g ~loom 4"(TYP.) -- j-- (IYP.I a o n z NU d I = Ew i $zu w d p o a v\ ' 4• ma 1 [) ` am 1 TYP. I_ E o zJ i c Li FRAME f" 3a BUCK SUB BUCK SUB BUCK BUCK MASONRY i v OPENING MASONRY ( ,0 OPENING 1 m U U Q U 1— j) o 0oIta a t zm 2X BUCK ANCHORING FRAME ANCHORING o N L z W Z = LQ 0 p 3 ti CONCRETE ANCHOR NOTES: N wa c 1. Concete anchorlocafions at the comers may bo adjuslcd to moinfuin the min. edge distance to mortar joints. vs n 2. Concrete anchor locollons noted of "MAX. ON CENTER" must be adjusted to moinfoin the min. edge distance to mortar joints, oddiffonol concrete onchon may be requked to ensue the'MAX. ON CENTER" dimension are not exceeded. w e O 3. Concrete anchor fobfe: OI oZU DATE 2/ 19 14 1. 0 solo N.T.S. owc. B*: JK m CMK. M: LFS oRnwrrc ub.: WOOD SCREW INSULUTION NOTES; a 1. Mointoln o minkrxrm 5/8"edge dutonce. I"end distance, 6 I"o.c. spocing of FL— 1 6542.6 0woodscrewstopreventtheIpi8ingofwood. n SHEEN 3 or 5 ,O ANCHOR ANCHOR MIN' I li F 2J( BUCK I I D IX BUCK K STEEL STUD I^ TYP. I MIN. CLEARANCE MIN. CLEARANCE TYPE SIZE EMBEDMENT l0 MASONRY i0 ADJACENT EDGE ANCHOR I1W s TAtCON I/I' 1-1/C Y 4• ElGO 1/P 1.1/M 1" f Ul1RACON H OMEETNG STILE REINFORCEMENT O fRAME J 0 0 0.067 1.77'------ I 2.4" -—{ d MEETING fill Z GLAZING BEAD LOCK fill REINFORCEMENT 3 HANDLE STILE REfNFORCEMENT L i--0.94"— OLOCK STILE or 0.74' o I, 0.09" -- R O.OSS 3 GLAZING BEAD 5 Sill RISER v I5S' 0 0 0 1 6 ROLLER TRACK y r_ _-Io ' T" 0 BOTTOM RAft REINFORCEMENT to v 0.0r' — I tr F-- 0.94- OHANDLE STILE N Z L E: 2119114 N.T.S. JK u BY: IFS 3 FL-1684Z 6 El 4 or 5 BILL OF MATERIALS REM R DESCRIPTION MATERIAL B 2X BUCK (SG >= 0.55) WOOD C 1/4" MAX. SHIM SPACE D 1/4" X 2-3/4" PFH ELCOOR ITW CONCRETE SCREW STEEL E MASONRY - 3.000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE F_ 10 X 7' PPH SMS (1-1/4" MIN. EMBEDMENT) STEEL J STEEL STUD Min. Thk .033" (ASTM A653 GRADE 33 Fy=33 ksi min., Fu=45 ksi min.) STEEL _ K 10 PPH SELF -DRILLING SMS STEEL I EXTRUDED VINYL FRAME (439)' RIGID PVC 2 EXTRUDED VINYL GLAZING BEAD (736A)' RIGID PVC 3 EXTRUDED VINYL GLAZING BEAD (425A) " RIGID PVC 4 BOTTOM RAIL (424B)' RIGID PVC 5 TOP RAIL (478)1 RIGID PVC 6 MEETING STILE (477)' RIGID PVC 7 LOCK STILE (476)' RIGID PVC 8 HANDLE STILE (475B)' RIGID PVC 9 MEETING STILE REINFORCEMENT 6063 - T5 ALUM 10 LOCK STILE REINFORCEMENT 6063 - T5 ALUM 1 I SASH LOCK 12 KEEPER 13 HANDLE STILE REINFORCEMENT 6063 - T5 ALUM 14 ROLLER (TRUTH 42433-1000) 15 SILL RISER 6063 - T5 ALUM 16 ROLLER TRACK 6063 - T5 ALUM 17 ANTI -LIFT ALUMINUM 6063 - T5 ALUM 18 BOTTOM RAIL REINFORCEMENT 6063 - T5 ALUM 20 WEATHERSTRIP (.187' X .290") THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". 5/8 GLASS BITE ---- 7/8" OA. GLASS THK. GLAZING SEALANT _ SIKAFLEX-552) N0 1lift 2 E Z Z (.1 mLOp M c i W P N rYj 5 O 0umaa`a a1 6 E Dz io d 1 /8" ANNEALED GLASS Q_ - — 0.090"SAFLEX® PVBINTERLAYER CD 1/8"ANNEALED GLASS o AIR SPACE 1/8"ANNEALEDGLASS METAL REINFORCED BUTYL u a 00 o Not approved for use above 30 feet in the "HVHZ". & Gl GLAZING DETAIL T, fJ 5/6' GLASS BITE 7/8" OA. GLASS THK. GLAZING SEALANT SIKAFLEX-552) 1/8"ANNEALED GLASS 0.090 SAFLEX0 PV8INTERLAYER 1 /8" ANNEALED GLASS AIRSPACE 1/8"TEMPERED GLASS o METAL REINFORCED BUTYL Sale: N.T.S. B*G. BY: JK G2 GLAZING DETAIL LFS DRnwiNG N0: FL- 16842.6 SHF,n 5 or 5 1