Loading...
HomeMy WebLinkAbout119 Placid Woods Ct 17-1277; HVACCITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: $ A D Job Address: 119 Placid Woods Ct Sanford Historic District: Yes No Parcel ID: 02-20-30-522-0000-0310 Residential 0 Commercial Type of Work: New Addition Alteration 0 Repair Demo Change of Use Move Description of Work: Replace existinq 2.5 ton AC system with new 14 SEER AC system including 8 KW electric heat. Plan Review Contact Person: Steven Perry Title: Owner Phone: 407-388-1300 Name Panneer Sundararajan Street: 2329 Stanmore Lane Fax: 407-210-8852 Email: steve n (cDel ectri cool. com City, State Zip: Plano TX 75025 Property Owner Information Phone: 469-223-6205 Resident of property? : __N4 Contractor Information Name ElectriCool Inc / Steven H Perry Phone: 407-388-1300 Street: 733 S Edgemon Ave Fax: 407-210-8852 City, State Zip: Winter Springs FL 32708 State License No.: CAC1817352 Architect/Engineer Information Name: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5t11 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application N0110E: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be Obund in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID S- 3_ Signature of Contractor/ ent Date Steven H Per Print Contractor/Agent's Name S 0 ignature of Notary -State of Florida Date MY COMMISSION k jF"ni7864J8zEXPIRES: February5, 20BondedThruNotaryPublicderwr Contractor/Agent is Personally o Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: COMMENTS: Revised: June 30, 2015 Permit Application ElectriCool Inc. ElectriCool Inc. 5703 Red Bug Lake Road Suite 322 Winter Springs, FL 32708-4969 407)388-1300 steven@electricool.com http://electricool.com Address Porzig Realty 705 S. French Ave. Sanford, FL 32771 Activity Proposal Date Proposal # 04/17/2017 2584 Exp. Date Job location 119 Placid Woods Ct Sanford Quantity Rate Amount Job location: 119 Placid Woods Ct Sanford Recommend replacing the system, also highly recommend replacing the refrigerant j lines running under the house since these are 17 years old and susceptible to rupturing with the new refrigerant. please note if the system is replaced by others please let us know so we may go back and pull all the new parts we installed to get the system running.**** 1) Remove and discard off property all existing heat pump equipment as per EPA requirements. 2) Install new pressure treated plywood deck to accommodate new air handler. 3) Make connections to existing duct -work. 4) Install 4" thick concrete pad and anchor down new heat pump unit as per building code. 5) Replace thermostat with digital programmable type (programmable required by code). 6) Re -use existing electrical wires and breakers, change breakers to match equipment if required. 7) 10 year parts warranty (if registered on line within 60 days of installation) 8) 1 year labor warranty. j York 2.5 ton 14 SEER AC system with 8 KW supplemental heat strip. 1 3,485.00 3,485.00 highly recommended but not required: 1 350.00 350.00 We recommend replacing the lines, The new refrigerant runs about 60% higher pressures than the old refrigerant, these lines can rupture. The cost to install new insulated refrigerant copper lines. Phone# 407-388-1300 n.. ti x TOfal FY Y3; 3 83513- 1VAC Licit CAC-1817352 Elec. Licit EC-13006674 Accepted By Accepted Date Property Record Card4P&%&6 F Parcel: 02-20-30-522-0000-031(l Owner: SUNDKRARA AN PANNEER Property Address: 1-19 PLACID) WOODS CT SANFORD, FL 32773 Parcel Information Parcel_ _ . 02-20-30-5 22-0000-0310 Owner SUNDARARAJAN PANNEER_______________________________ __-___..__________ Property Address 119 PLACID WOODS CT SANFORD, FL 32773 Mailing 12329 STANMORE LN PLANO, TX 75025- j_---- _ _— ------ - --- _------- . ___.____ --------- I------------,"-,-,"---," _ --------- Subdivision Name 1 PLACID WOODS PH 3 t_____ __________ ___ _ _ _ ______ ---------- Tax District 1 Sl-SAN FORD DOR Use Code ; 01-SINGLE FAMILY Exemptions uMESA a z, Value Summary 2017 Working 1 2016 Certified I Values i Values i 1......_--- _.---- _..... ....... ..._...._._ Valuation Method Cost/Market Cost/Market f Number of Buildings 1 1 Depreciated Bldg Value $102 573 87 705 DepreciatedEXFTVal ue Land Value (Market) $25 000 18 000 Land Value Ag 1 Ju UMarhwt ,t lire $127,573 105 705 Portabil ity Adj Save Our Homes Adj $0 0 Amendment 1 Adj $0 0 P& G Adj .__ $0 0 I Assessed Value $127,573 105,705 ! Tax Amount without SOH: $2,119.00 2016 Tax Bill Amount $2,119.00 Tax Estimator Save Our Homes Savings: $0.00 1 RIM Notice Help Does NOT INCLUDE Non Ad Valorem Assessments Legal Description LOT 31 PLACID WOODS PH 3 PB 56 PGS 65 & 66 Taxes Taxing Authority Assessment Value Exempt Values Taxable Value City Sanford 127 573 0 127,573 r County General Fund- 127 573 0 . 127 573 t Schools 127,573 0 127,573 County Bonds 127,573 0 127,573 f SJWM( SaintJohns Water Management) 127,573 : 0 127,573 4 Sales Description.. Date Book Page Amount Qualified E i Vac/Imp i SPECIAL WARRANTY DEED 3/1/2017 i 88 128,000 No Improved CERTIFICATE OF TITLE 9/1/2016 08766 6 e54134,500 No Improved SPECIAL WARRANTY DEED 5/1/2015 08511 074' 100 No Improved i CERTIFICATE OF TITLE 5/1/2015 08 l n. 0970 74 100 No Improved SPECIAL WARRANTY DEED 5/1/2000 03857 9t,2 82,300 Yes Improved FindmparahE S;des Land Method Frontage Depth Units units Price i Land %lue LOT 1 25,000.00 ' 25,000 Building Information