Loading...
HomeMy WebLinkAbout361 White Cedar Rd 18-4433; (A) NEW OFFICE BUILDINGCITY OF SANFORD 1 Zola BUILDING & FIRE PREVENTION PERMIT APPLICATION tApplicationNo: a—L) L4 Documented Construction Value: s 2,322,437.72 Job Address: 361 S. White Cedar Rd Sanford FL 32771 Historic District: Yes No 0 Parcel ID: 26-19-30-5AE-0400-0000 Residential Commercial 0 Type of Work: New © Addition Alteration Repair Demo Change of Use Move Description of Work: ^F and a new 1-sto office building with space for storage and manufacturing. Plan Review Contact Person: pawn Moss Title: Project Asst Phone: 407-628-4353 Fax: Email: dmoss@gomezconstruction.com Property Owner Information Name CLX Holdings LLC Phone: 407-878-2774 Street: 645 Hickman Circle Resident of property? City, State Zip. Sanford FL 32771 Contractor Information Name Orlando Gomez (Gomez Construction Company) Street: 7100 SW 44th St Miami FL 33155 / 750 Jackson Ave Winter Park 32789 City, State Zip: Miami FL 33155 Phone: 305-661-76601407-628-43533 Fax: State License No.: CGCO05258 Architect/ Engineer Information Name: Blankenship Architects Inc. Phone: 407-331-8868 Street: 540 Lake Faith Circle City, St, Zip: Maitland FL 32751 Bonding Company: Address: Fax: E- mail: nelson@blankenshiparchitects.com Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51h Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application e 1k.. Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Nt3TICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws_Vgulating construction and zoning. or uwner/Agent 111 m Sctor/Agent Date 1)] S /! 5 Pn o tractor/Agent's Name i25 . 2 i G 1( 6 Notary Public State of Florida .++++u,, Susan M Rodichok 'cio'"YR°«',Y ANNETTE BLAND g My Commis GG 131915 . Notary Public •State of Florida orn Expires 12l04l2021 Commission # GG 060623 o My Comm. Expires Jan 16, 2018 Owner/ Agent is 9---Personally Known to Me or Contracto or Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical PlumbingE] Gas Roof n Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps, Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: - UTILITIES: ENGINEERING: 4 LE" FIRE: COMMENTS: t Revised: June 30, 2015 Permit Application City of Sanford Building Division 0 FICE P.O. Box 1788 Sanford, Florida 32771 Phone: 407.688.5150 PERMIT Fax: 407.688.5152 CONDITIONS OF PERMIT Date: November 20, 2018 Contact Person: Dawn Moss Contact Phone Number: Contact Fax Number: Contact E-mail Address: Building Permit Application Number: 18-4433 Project: New Building Job Address: 361 South White Cedar Road The above permit is issued under the following conditions: 1. Submit two hard sets of site specific producppprovals as listed on sheet A-002. f I Contractor / Owner / Agent Signature 11IL/ Please direct any questions you may have to Joy Deen at 407.688.5064 or fax to 407.688.5152. You may also contact me by e-mail at joy.deen(a- sanfordfl.gov. Respectfully, Joy teen, Plans Examiner 41 y t . 2018 CITY OF SANFORD r tt BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: $ 2,322,437.72 Jolt Address: 361 S. White Cedar Rd Sanford FL 32771 Historic District: Yes No El Parcel ID: 26-19-30-5AE-0400-0000 Residential Commercial El Type of Work: New © Addition Alteration Repair Demo Change of Use Move Description of Work:-&ite-14tark and a new 1 Plan Review Contact Person: Dawn Moss Phone: 407-628-4353 Fax: office buildinq with space for Title. Project Asst Email: dmoss@gomezconstruction.com Property Owner Information Name CLX Holdings LLC Phone: 407-878-2774 Street: 645 Hickman Circle City, State Zip: Sanford FL 32771 Resident of property? : Contractor Information Name Orlando Gomez (Gomez Construction Company) Street: 7100 SW 44th St Miami FL 33155/750 Jackson Ave Winter Park 32789 City, State Zip: Miami FL 33155 Phone: 305-661-7660 / 407-628-43533 Fax: State License No.: CGCO05258 Architect/Engineer Information Name: Blankenship Architects Inc. Phone: 407-331-8868 Street: 540 Lake Faith Circle Fax: City, St, Zip: Maitland FL 32751 Bonding Company: Address: E-mail: nelson@biankenshiparchitects.com Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5t11 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws_pgulating construction and zoning. Date W Signature of Contractor/Agent Date I:n &S S I & Pn o tractor/Agent's Name 2 > . [ Ia Notary Ruble Stats of Florida ` weeSusanMRodichok + R,? o"., ANNETTE BLAND My Commission GG 131915 : Notary Public - State of Florida Expires 12/04/2021 " ' Commission # GG 060623v}, c.^^` My Comm. Expires Jan 16, 2018 Owner/Agent is personally Known to Me or Contracto or Produced ID Type of ID Produced'TD Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical© Plumbing Gas[] Roof[] Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures, Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTEWATER: ENGINEERING: FIRE: BUILDING: COMMENTS: Revised: June 30, 2015 Permit Application COUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 18100007 DATE: September 06, 2018BUILDINGAPPLICATION #: 18-10000766 BUILDING PERMIT NUMBER: 18-10000766 UNIT ADDRESS: WHITE CEDAR RD S 361 26.19-30-5AE-0400-0000 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: CLX HOLDINGS LLC ADDRESS: 645 HICKMAN CIRCLE SANFORD FL 32771 LAND USE: OFFICE W/STORAGE MANUFACTURING TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 361 S WHITE CEDAR ROAD Z CLX ENGINEERINGOFFICE / NEW CONSTRUCTION FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUETYPEDISTSCHEDRATEUNITSTYPE 1- ....... ROADS -ARTERIALS CO -WIDE ORD Wareh ROADS -COLLECTORS CO -WIDE ORD 358.00 5.790 1000gsft 2,072.82 Warehousing* ROADS -ARTERIALS CO -WIDE ORD 00 5.790 1000gsft 00 Manufacturing* ROADS -COLLECTORS CO -WIDE ORD 519.00 3.621 1000gsft 1,879.29 Manufacturing* ROADS -ARTERIALS CO -WIDE ORD 00 3.621 1000gsft 00 Office < 100K Square Feet ROADS -COLLECTORS CO -WIDE ORD 1,545.00 10.387 1000gsft 16,047.91 Office < 100K Square Feet FIRE RESCUE N/A 00 10.387 1000gsft 00 LIBRARY N/A 00 SCHOOLS N/A 00 PARKS N/A 00 LAW ENFORCE N/A 00 DRAINAGE N/A 00 CREDIT FEES: 00 SCI ROAD ARTERIALS C Single Family Housing 705.00 1.000 dwl unit 705.00- AMOUNT DUE 19,295.02 PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THESEMINOLECOUNTYROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONALISSUANCEOFABUILDINGPERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEESMUSTBEEXERCISEDBYFILINGAWRITTENREQUESTWITHIN45CALENDARDAYSOFTHEDATEABOVE, BUT NO LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEWMUSTMEETTHEREQUIREMENTSOFTHECOUNTYLANDDEVELOPMENTCODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE BUSINESS OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORDBUILDINGDEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCETHECOUNTYBUILDINGPERMITNUMBERATTHETOPLEFTOFTHISSTATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOTISSUEDWITHIN60CALENDARDAYSFROMTHEDATEABOVE Seminole county Bldg, & Fire Div. 1101 E. First St. Sanford, FL 32771 A c CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION l Application No: qn , Documented Construction Value: s 2,322,437.72 Job Address: 361 S. White Cedar Rd Sanford FL 32771 Historic District: Yes No 0 Parcel 1D: 26-19-30-5AE-0400-0000 Residential Commercial Q Type of Work: New © Addition Alteration Repair Demo Change of Use Move El Description of Work: 1 Plan Review Contact Person: pawn Moss Title: Project Phone: 407-628-4353 Fax: Email: dmoss@gomezconstruction.com Property Owner Information Name CLX Holdings LLC Phone: 407-878-2774 Street: 645 Hickman Circle Resident of property? City, State Zip: Sanford FL 32771 Contractor Information Name Orlando Gomez (Gomez Construction Company) Street: 7100 SW 44th St Miami FL 33155 J 750 Jackson Ave Winter Park 32789 City, State Zip: Miami FL 33155 Phone: 305-661-7660 1407-628-43533 Fax: State License No.: CGCO05258 Architect/Engineer Information Name: Blankenship Architects Inc. Phone: 407-331-8868 Street: 540 Lake Faith Circle Fax: City, St, Zip: Maitland FL 32751 Bonding Company: Address: E-mail: nelson@blankenshiparchitects.com Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. l certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5111 Edition (2014) Florida Building; Code Revised: June 30, 2015 Permit Application 4e V. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws gulating construction and zoning. 06Se t2018 F M of Owner/Agent Date Signature of Contractor/Agent Date Wilcox sS J-(/ er/Agent's Name Pr o tractor/Agent's Name 2,(b/R>tc 10 Notary Public State of Florida , Pa — c R ueSusanMRadichok ;ro , ANNETTE BLAND My Commission GG 131818 : Notary Public •State of Florida eta ntatpires t21o4f2021 Commission # GG 060623 My Comm. Expires Jan 16, 2018 tellOwner/ Agent is 9--personally Known to Me or Cantracta or Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing0 Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps, Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: Cr7r s. 1 Gas Roof Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No 7S4 UTILITIES. WASTE WATER: FIRE: BUILDING: Revised: June 30, 201 S Permit Application Yn t0V I Zola V CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: i 8-L)14 Documented Construction Value: S 2,32 2,437.72 Job Address: 361 S. White Cedar Rd Sanford FL 32771 Historic District: Yes No Parcel ID: 26-19-30-5AE-0400-0000 Residential Commercial Q Type of Work: New © Addition Alteration Repair Demo Change of Usc Move Description of Work: -&iteWwk and a new I -story office building with space for storage and manufacturing. Plan Review Contact Person: Dawn Moss Title: Project Asst Phone: 407-628-4353 Fax: Email: dmoss@gomezconstruction.com Name CLX Holdings LLC Street: 645 Hickman Circle City, State Zip: Sanford FL 32771 Property Owner Informations t LJ Phone: 407-878-2774 Resident of property? : Contractor information Name Orlando Gomez (Gomez Construction Company) Street: 7100 SW 44th St Miami FL 33155 / 750 Jackson Ave Winter Park 32789 City, State Zip: Miami FL 33155 Phone: 305-661-76601407-628-43533 Fax: State License No.: CGCO05258 Architect/Engineer Information Name: Blankenship Architects Inc. Phone: 407-331-8868 Street: 540 Lake Faith Circle City, St, Zip: Maitland FL 32751 Bonding Company: Address: Fax: E-mail: nelson@blankenshiparchitects.com Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 511 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application 10 R NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws_pgulating construction and zoning. of Owner/Agent Date Signature of Contractor/Agent Date hPnoractor/Agents Name ZrD/ZCt tc ( G may. Notary Public State of Ftodda aaiep r+ Susan M Rodichok ;io`Y r`"., w ANNETTE fat AND a My Commission GG 131915 +' = Notary Public - State of FloridaofndiQExpires12/o41 0 1 - Commission # GG 060623yYRT My Comm. Expires Jan 16, 2018nnuq Owner/Agent is 9--personally Known to Me or Contracto or Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building[ Electrical '"`-chanical FT"` I turnbingE[ Gas[] Roof[] Construction Type: ', ''lam Occupancy Use: r . Flood Zone' Total Sq Ft of Bldg: _ Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures . 4— Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: Fire Alarm Permit: Yes No [] WASTE WATER: FIRE ' /i Xt.. BUILDING: //- -.70 -le vr Revised: June 30, 2015 Permit Application CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION FIRE PLAN REVIEW SERVICE. FEES PHONE: 407.688.5052 FAX: 407.688.5051 DATE: u/s j KZ — PERMIT NUMBER: - BUSINESS/PROJECT NAME: ADDRESS: CONTACT NAME: PHONE: PLAN REVIEW INFORMATION CONSTRUCTION HCIO [IFIRE ALARM [IFIRE SPRINKLER [)HOOD [ ]PAINT BOOTH []TANK DOES 20% REDUCTION IN FIRE IMPACT FEES APPLY: YES NO TOTAL FEES: 111--'St.PA Parcel View: 26-19-30-5AE-0400-0000 Page I of 2 P pqrty Record Card Parcel: 26-19-30-5AE-0400-0000 I7PAN Property Address_ Parcel Information Value Summary Parcel 26-19-30-5AE-0400-0000 Owner(s) Property Address 361 S iIT.E CEDAR RD SANFORD, FL 32771-6650 Mailing 645 HICKMAN CIR SANFORD, FL 32771 Subdivision Name SMITHS M M Tax District Sl-SANFORD DOR Use Code 40-VAC INDUSTRIAL GENERAL Exemptions Legal Description PT OF BLK 4 BEG NW CDR RUN E TO NE CDR S 500 FT NWLY TO PT 115 FT S OF BEG N TO BEG (LESS W 10 FT) M M SMITHS SUBD PB I PG 55 Taxes I Taxing Authority i County General Fund Schools City Sanford SJWM(Saint Johns Water Management) County BondsL-- . ... . ...... . ..... . -------- --- - Sales 2018 Working 2017 Certified----,"] Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 0 0 Depreciated Bldg Value Depreciated EXFT Value Land Value (Market) 718,270 690,645 Land Value Ag Just/Market Value 718,270 690,645 Portability Ad Save Our Homes Adj 0 0 Amendment 1 Adj 0 283,658 P&G Adj 0 0 Assessed Value 718270 406.987 Tax Amount without SOH $9,612.00 2017 Tax 961 Amount $9,612,00 Tqx'Esinqtor Save Our Homes Savings $0.00 TRIM Notice Help Does NOT INCLUDE Non Ad Valorem Assessments Assessment Value Exempt Values Taxable Value 718,270 0 718,270 718,270 0 718,270 718,270 0 718,270 718,270 0 718,270 718,270 0 718,270 Description Date Book Page Amount Qualified Vactimp WARRANTY DEED 1/l/2017 08842 1838 850,000 Yes Vacant WARRANTY DEED 2/1/2011 07533 0187 412,500 Yes Vacant CORRECTIVE DEED 4/lt2007 06663 1785 100 No Vacant I WARRANTY DEED 1211/2006 06541 0545 1,050,000 No Vacant WARRANTY DEED 8/1 t2006 06379 1928 600,000 No Improved ADMINISTRATIVE DEED 8/112006 06379 1926 525,000 No Improved PROBATE RECORDS 101112005 05989 0628 100 No Improved QUIT CLAIM DEED 1/l/1993 02 37 1760 100 No Improved QUIT CLAIM DEED 9/111992 02491 1769 100 No Improved i WARRANTY DEED 1/1/1987 01806 0602 125,000 Yes Improved Page I of 2 (11 items) [I] http://parceidetail.scpafl.org/ParcelDetaillnfo.aspx?PID=2619305AE04000000 9/5/2018 INSPECTION SEQUENCE BP# 18-4433 ADDRESS: 361 South White Cedar Road BUILDING PERMIT Min Max Inspection Description 10 Footer / Setback Stemwall 10 Slab / Mono Slab Lintel / Tie Beam Fill Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In 20 Frame 30 Insulation Rough Firewall Screw Pattern 40 Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com'l) Building Ceiling Grid Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence 1000 Final Commercial — Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) ELEcTRjCAL PERMIT Min Max Inspection Description Electric Underground 10 Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough 20 Electric Rough Pre -Power Final Temporary Pole 1000 Electric Final Min110 Max Inspection Description Rough Plumb Plumbing Underground 20 Plumbing 2 "d Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough 1000 Plumbing Final MECHANICAL PERMIT Min Max Inspection Description 10 Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap 1000 Mechanical Final REVISED: June 2014 This appendix is not part of this standard. It Is merely informative and does not contain requirements necessary for conformance to the standard. It has not been processed according to the ANSI requirements for a standard and may contain material that has not been subject to public review or a consensus process. Unresolved objectors oil informative material are not offered the right to appeal to ASHRAE or ANSI) APPENDIX A RECOMMENDED ASHRAEIACCA COMPLIANCE FORM FOR STANDARD 183 PERMIT # Suodfng or Zone Name: CLX Engineering Facilities Building Location or Address: 301 South White Cedar Road, Sanford, FL Design Conditions: Cooling — Heating Weather Data Used Drlando,FL(95DBZ74, SW3) 0r1ando,FL(38DB) Indoor Dry Bulb Design Temperature 7 5 0 F 6 8 O F Indoor Design Relative Humidity 50 RH 451RH Load Calculation Method: (indkote wNch of ft kdlowkV me"s is used) L1 C, T&CLF—Cooling Load renWarature DtftamcelCooling Load Factor metho& dB—Heat Balance mettiods; TETOITA—Total Equivalent Temperaftye Diftrancefrkne Averaging me#WsI Ll TF114—Transter Function Methods Ll RTS—Radmint rtm Series mattlOds Ll OTHER (please specify) HLUZ The undersigTot 1* used to Pao r4' ... 0 SWxr0edby-.-', 0 S N a Information is correct and that the procedures comply with ANSVASHRAEIACCA Standard 183. I I OFFICE CONSULTING ENGINEERS MECHANICAL I EtECTRICAL I PLUMBING I FIRF PROTECTION I STRUCTURAL ANSI/ASHP,AFACCA Standard 183-2007 W Wrgdenginmrs.com 2151 SOUTH ALT, A- SUM 2" JUPITE&FLIU77 436117410165 CEKT OF AUtH 54S4 Trane C.D.S. 3600 Parrimel Creek Rd La Crosse, Wl 54601 USA Tel (608)787-3926 Fax (608)787-3005 http://www. tranecds.com rJMNAE" October 14"', 2015 Subject: TRACEIrm 700 v6.3.2 Compliance with ANSI/ASI-IRAE Standard 140-2011 Dear TRACE User: We are pleased to inform you that TRACE 700 v6.3.2 was tested in compliance with ANSI/ASHRAE Standard 140-2011, Standard Method oI'Test for the Evaluation qfBidNin g , Energy Analysis Computer Programs. Test results, supplemented by graphs and explanatory notes, accompany this letter. As you may know, ANSI/ASHRAE/IESNA Standard 90. 1, Energj,'Standard for Buildings,, E-xeept Low -Rise Residential Buildings, Stipulates that any computer program that is Used to demonstrate code compliance via the performance path's Energy Cost Budget Method must be tested in accordance with Standard 140. TRACE 700 v6.3.2 has completed the BESTEST validation for calculation and comparison with similar analysis programs as required by ASHRAI-1 Standard 140. Standard 90.1 defines Minimum requirements for the design of energy -efficient buildings and is Used by many state and local code -writing bodies as the "standard of care" in their jurisdictions. Building- 4:1 energy Simulation programs, such as TRACE 700, are used to estimate the difference in energy costs between the design- and budget -building models specified in Section I I of Standard 90.1. If You have questions about the testing documentation that accompanies this letter, or about any of Trane's design and analysis tools, please contact our C.D.S. Support Center by phoning (608) 787-3926 or e-mailing cdshelpctrane.com. Best regards, Caitlin Bohnert ASHRAE Standard 140 Coordinator Trane C.D.S. Attachments: Results and modeling notes from Standard 140 testing of TRACE 700 CLX Location Building owner Program user Company Comments Orlando, FL CLX RGD & Associates Inc RGD & Associates Inc By RGD Dataset name X:1_ACTIVE_PROJECTS117-1213 CLX DESIGN BUILDIMEP_PROJ ECTIMEC HANICALICOOLI NG LOADS117-1213.TRC Calculation time 11:38 AM on 01/16/2018 TRACE® 700 version 6.3.3 Location Orlando, Florida Latitude 28.0 deg Longitude 81.0 deg Time Zone 5 Elevation 106 ft Barometric pressure 29.8 in. Hg Air density 0.0767 Ib/cu ft Air specific heat 0.2444 Btu/Ib-°F Density -specific heat product 1.1109 Btu/h-cfm-°F Latent heat factor 4,890.3 Btu-min/h-cu ft Enthalpy factor 4.5449 lb-min/hr-cu ft Summer design dry bulb 95.0 F Summer design wet bulb 74.8 F Winter design dry bulb 38.0 F Summer clearness number 0.95 Winter clearness number 0.95 Summer ground reflectance 0.20 Winter ground reflectance 0.20 Carbon Dioxide Level 400 Ppm Design simulation period January - December Cooling load methodology TETD-TA1 Heating load methodology UATD 7RAGE700 System Checksums By RGD System - 001 Single Zone COOLING COIL PEAK Peaked at Time: Mo/Hr: 6 / 13 Outside Air: OADB/WB/HR: 93 / 74 195 Space Plenum Net Sens. + Lat. Sens. + Lat Total Btu/h Stu/h Btu/h Envelope Loads Skylite Solar 0 0 0 Skylite Cond 0 0 0 Percent Of Total 0 0 CLG SPACE PEAK Mo/Hr: Sum of OADB: Peaks Space Percent Sensible Of Total Btu/h (%) 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 38 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 Percent Of Total 0.00 0.00 TEMPERATURES Cooling SADB 54.0 Re Plenum 85.0 Return 75.0 Ret/OA 74.8 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 69.3 59.9 68.0 68.0 0.0 0.0 0.0 Roof Cond 0 1,407 1 A07 7 0 0 Roof Cond 0 420 11.95 AIRFLOWS Glass Solar 6,098 0 6,098 32 6,084 36 Glass Solar 0 0 0.00 Glass/Door Cond 696 0 696 4 701 4 Glass/Door Cond 1,696 1,696 48.23 Cooling Heating Wall Cond 724 411 1,135 6 744 4 Wall Cond 1,232 2,363 67.18 Diffuser 718 718 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0 0.00 0.00 Terminal 718 718 Floor 0 0 0 0 0 Floor 0 0 0 0 Main Fan 718 718 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 7.519 1,818 9,337 49 7,529 45 Sub Total =_> 2,929 4,480 127.36 Nom Vent 75 75 AHU Vent 75 75 Internal Loads Infil 0 0 Internal Loads Lights 2,431 0 2.431 13 2,431 15 Lights 2,431 2,431 69.11 MinStop/Rh 0 0 People 5.601 0 5,601 29 3,384 20 People 3,384 3,384 96.21 Return 718 718 Misc 1.501 0 1,501 8 1,501 9 Misc 1,501 1,501 42.67 Exhaust 75 75 Sub Total =_> 9,533 0 9,533 50 7,316 44 Sub Total ==> 7,316 7,316 208.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 1.918 1,918 0 0 1,913 11 Ceiling Load 1,551 0 000 Leakage Own 0 0 Ventilation Load 0 0 63 0 0 0 Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing -3,846 -3,846 109.34 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 0 0.00 ENGINEERING CKS Exhaust Heat 0 0 0 OA Preheat Diff. 2,508 71.30 Cooling Heating Sup. Fan Heat 138 1 RA Preheat Diff. 0 0.00 CIA 10.5 10.5 Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 cfm/ft' 1.19 1.19 Duct Heat Pkup Underflr Sup Ht Pkup 0 0 0 0 0 Underfir Sup Ht Pkup 0 0.00 cfm/ton 339.30 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'tton 285.30 Btu/hrft' 42.06 5.15 Grand Total ==> 18,970 100 19,071 100,00 16,758 100.00 Grand Total ==> 1,010 3,517 100.00 No. People 14 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DBNVB/HR ton MBh MBh cfm F °F gr/lb F °F gr/lb Main Cig 1.6 19.1 16.6 718 74.8 61.0 58.3 53.8 51.6 53.61 Aux Cig 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.5 6.3 3.1 75 91.5 77.6 121.8 54.0 53.9 62.3 Total 2.1 25.4 AREAS Gross Total Glass w Floor 604 Part 0 Int Door 0 ExFlr 0 Roof 604 0 0 Wall 1,095 112 10 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg' MBh cfm F F' Main Htg 0.6 718 68.5 69.3 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 2.5 75 38.0 68.0 Total 3.1 Project Name: CLX TRACED 700 v6.3.3 calculated at 11:38 AM on 01/16/2018 Dataset Name: 17-1213.TRC Alternative - 1 System Checksums Report Page 1 of 8 System Checksums By RGD Svstem - 002 Single Zone COOLING COIL PEAK Peaked at Time: Mo/Hr: 8 / 12 Outside Air: OADB/WB/HR: 89 / 74 / 102 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h { %) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 CLG SPACE PEAK Mo/Hr: Sum of OADB: Peaks Space Percent Sensible Of Total Btu/h (%) 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 38 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 Percent Of Total 0 00 0.00 TEMPERATURES Cooling SADB 54.0 Re Plenum 85.1 Return 75.0 ReVOA 74.9 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 69.2 59.4 68.0 68.0 0.0 0.0 0.0 Roof Cond 0 1,670 1,670 5 0 0 Roof Cond 0 546 11.49 AIRFLOWS Glass Solar 20,538 0 20,538 57 20,538 62 Glass Solar 0 0 0.00 Glass/Door Cond 1,213 0 1,213 3 1,213 4 Glass/Door Cond 3,393 3,393 71.42 Cooling Heating Wall Cond 1,198 893 2,091 6 1,198 4 Wall Cond 1,646 3,274 68.92 Diffuser 1,429 1,429 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0 0 0.00 0.00 Terminal 1,429 1,429 Floor 0 0 0 0 0 Floor 0 0 0 Main Fan 1,429 1,429 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 22,949 2,562 25,512 71 22,949 69 Sub Total =_> 5,039 7.213 151.83 Nom Vent 86 86 AHU Vent 86 86 internal Loads Infil 0 0 Internal Loads 0 0 Lights 3.127 0 3,127 9 3,127 9 Lights 3,127 3,127 65.81 MinStop/Rh People 4,909 0 4.909 14 2,926 9 People 2,926 2,926 61,59 Return 1,429 1,429 Misc 1,772 0 1.772 5 1,772 5 Misc 1.772 1,772 37.31 Exhaust 86 86 Sub Total ==> 9,808 0 9,808 27 7,825 23 Sub Total ==> 7,825 7.825 164.71 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 2,562 21562 0 0 2,562 8 Ceiling Load 2,174 0 0.00 Leakage Own 0 0 Ventilation Load 0 0 328 1 0 0 Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing -2,511 -2,511 52.85 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 0 0.00 ENGINEERING CKS Exhaust Heat 0 0 0 OA Preheat Diff. 2,852 60.04 Cooling Heating Sup. Fan Heat 275 1 RA Preheat Diff. 0 0.00 OA 6.0 6.0 Ret. Fan Heat 0 0 0 Additional Reheat 0 0,00 cfmlft' 1.78 1.78 Duct Heat Pkup Underflr Sup Ht Pkup 0 0 0 0 0 Underfir Sup Ht Pkup 0 0.00 cfmtton 397.61 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 Wilton 222.88 Btulhr•ft' 53.84 5.24 Grand Total ==> 35,319 0 35,922 100.00 33,337 100.00 Grand Total ==> 1,898 4,751 100.00 No. People 12 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR ton MBh MBh cfm F °F gr/lb F °F gr/lb Main CIg 3.0 35.9 33.4 1,429 74.9 60.1 54.1 53.8 51.0 51.5 Aux CIg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.6 7.2 3.6 86 91.5 77.6 121.8 54.0 53.9 62.3 Total 3.6 43.1 AREAS Gross Total Glass ft' Floor 801 Part 0 Int Door 0 EXFIr 0 Roof 801 0 0 wall 1.612 224 14 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg', MBh cfm F F' Main Htg 1.3 1,429 68.4 69.2' Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 2.9 86 38.0 68.0 Total 4.2 Project Name: CLX TRACE@ 700 v6.3.3 calculated at 11:38 AM on 01/16/2018 Dataset Name: 17-1213.TRC Alternative - 1 System Checksums Report Page 2 of 8 System Checksums By RGD System - 003 Single Zone COOLING COIL PEAK Peaked at Time: Mo/Hr: 6 / 15 Outside Air: OADBNVB/HR: 95 / 75 / 98 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h {%) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 CLG SPACE PEAK Mo/Hr: Sum of OADB: Peaks Space Percent Sensible Of Total Btu/h (%) 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 38 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 Percent Of Total 0.00 0.00 TEMPERATURES Cooling SADB 54.0 Ra Plenum 84.7 Return 75.0 ReVOA 74.6 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 71.4 63.2 68.0 68.0 0.0 0.0 0.0 Roof Cond 0 4,657 4,657 25 0 0 Roof Cond 0 1,316 18.69 Glass Solar 1,280 0 1,280 7 1,280 8 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 513 0 513 3 513 3 Glass/Door Cond 848 848 12.05 Cooling Heating Wall Cond 851 492 1,343 7 837 5 Wall Cond 1,263 2,456 34.88 Diffuser 710 710 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 710 710 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0 Main Fan 710 710 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 2,643 5,150 7.793 42 2,629 16 Sub Total ==> 2.111 4,621 65.62 Norn Vent 130 130 AHU Vent 130 130 Internal Loads Internal Loads Infiil 0 0 Lights 5,079 0 5.079 28 5,079 31 Lights 5,079 5,079 72.12 MinStop/Rh 0 0 People 2.734 0 2,734 15 1,519 9 People 1,519 1.519 21.57 Return 710 710 Misc 2,281 0 2,281 12 2,281 14 Misc 2,281 2,281 32.39 Exhaust 130 130 Sub Total ==> 10.093 0 10,093 55 8,878 54 Sub Total ==> 8,878 8,878 126.08 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 5,038 5,038 0 0 5,068 31 Ceiling Load 2,509 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 364 2 0 0 Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing -6,955 -6,955 98.77 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 0 0.00 ENGINEERING CKS Exhaust Heat 0 0 0 OA Preheat Diff. 4,344 61.69 Cooling9 Heating Sup. Fan Heat 137 1 RA Preheat Diff. 0 0.00 OA 18.3 18.3 Ret Fan Heat 0 0 0 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 cfnv t' 0.43 0.43 Underfir Sup Ht Pkup 0 0 Underfir Sup Ht Pkup 0 0.00 cfmiton 290.42 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'tton 672.00 Btu/heft' 17.86 2.92 Grand Total =_> 17,774 112 18,387 100.00 16,575 100.00 Grand Total ==> 2,698 7,042 100.00 1 No. People 6 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR ton MBh MBh cfm F °F gr/lb F 'F gr/lb Main Clg 1.5 18.4 16.5 710 74.6 60.5 56.4 53.8 51.3 52.4 Aux Cig 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.9 11.0 5.4 130 91.5 77.6 121.8 54.0 53.9 62.3 Total 2A 29.4 AREAS Gross Total Glass ft2 Floor 1,644 Part 0 Int Door 0 ExFlr Roof 0 1,644 0 0 Wall 1.005 56 6 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm F F Main Htg 0.5 710 70.8 71.4 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0!. Humidif 0.0 0 0.0 0.0' Opt Vent 4.3 130 38.0 68.0' Total 4.8 Project Name: CLX TRACED 700 v6.3.3 calculated at 11:38 AM on 01/16/2018 Dataset Name: 17-1213.TRC Alternative - 1 System Checksums Report Page 3 of 8 System Checksums By RGD Svstem - 004 Single Zone COOLING COIL PEAK Peaked at Time: Mo/Hr: 6 / 19 Outside Air: OADB/WB/HR: 88 / 73 / 99 Space Plenum Net Sens. + Lat. Sens. + Lat Total Btu/h Btu/h Btu/h Envelope Loads Skylite Solar 0 0 0 Skylite Cond 0 0 0 Percent Of Total 0 0 CLG SPACE PEAK Mo/Hr: Sum of OADB: Peaks Space Percent Sensible Of Total Btu/h (%) 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 38 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 Percent Of Total 0.00 0.00 TEMPERATURES Cooling SADB 54.0 Ra Plenum 83.7 Return 75.0 Ret/OA 74.7 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 69.8 60.6 68.0 68.0 0.0 0.0 0.0 Roof Cond 0 1,259 1,259 4 0 0 Roof Cond 0 674 7.12 AIRFLOWS Glass Solar 13,080 0 13,080 36 13,080 42 Glass Solar 0 0 0.00 Glass/Door Cond 1,954 0 1,954 5 1,954 6 Glass/Door Cond 3,816 3,816 40,36 Cooling Heating Wall Cond 1,247 1,356 2,603 7 1.247 4 Wall Cond 1,303 2,822 29.85 Diffuser 1,329 1,329 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0 0 000 0.00 Terminal 1,329 1,329 Floor 0 0 0 0 0 0 0 0 0 0 Floor Adjacent Floor 0 0 0 Main Fan 1,329 1,329 Adjacent Floor Infiltration 0 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 16,281 2,616 18,896 53 16,281 53 Sub Total ==> 5,118 7,311 77.34 Nom Vent 204 204 AHU Vent 204 204 Internal Loads Internal Loads Infil 0 0 Lights 4.346 0 4,346 12 4,346 14 Lights 4,346 4,346 45.98 MinStop/Rh 0 0 People 10,320 0 10,320 29 5,733 18 People 5,733 5,733 60.65 Return 1,329 1,329 Misc 2,072 0 2,072 6 2,072 7 Misc 2,072 2,072 21.91 Exhaust 204 204 Sub Total =_> 16,738 0 16,738 47 12,152 39 Sub Total ==> 12,152 12.152 128.54 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 2,577 2,577 0 0 2,577 8 Ceiling Load 2,193 0 0.00 Leakage Own 0 0 Ventilation Load 0 0 51 0 0 0 Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing -7,491 -7,491 79.24 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 0 0.00 ENGINEERING CKS Exhaust Heat 0 0 0 CA Preheat Diff. 6,803 71.96 Cooling Heating Sup. Fan Heat 256 1 RA Preheat Diff. 0 0.00 CIA 15A 15.4 Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 cfm/ft' 1.42 1.42 Duct Heat Pkup Underflr Sup Ht Pkup 0 0 0 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 300.25 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'tton 211.66 Btu/hr-ft' 56.69 8.51 Grand Total ==> 35,596 38 35,941 100,00 31,009 100.00 Grand Total ==> 2,650 9,454 100.00 No. People 23 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR ton MBh MBh cfm F °F gr/lb F °F gr/lb Main Cig 3.0 35.9 30.9 1,329 74.7 61.1 59.3 53,8 51.6 53.7 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 1.4 17.2 8,5 204 91.5 77.6 121.8 54.0 53.9 62.3 Total 4.4 53.1 AREAS Gross Total Glass ft' 1%) Floor 937 Part 0 Int Door 0 ExFIr 0 Roof 937 0 0 Wall 1,425 252 18 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm F F, Main Htg 1.2 1,329 69.0 69.8' Aux Htg 0.0 0 0.0 0.0',, Preheat 0.0 0 0.0 0.0' Humidif 0.0 0 0.0 0.0 Opt Vent 6.8 204 38.0 68.0 Total 8.0 Project Name: CLX TRACED 700 v6.3.3 calculated at 11:38 AM on 01/16/2018 Dataset Name: 17-1213.TRC Alternative - 1 System Checksums Report Page 4 of 8 System Checksums By RGD 5vstem - 005 Single Zone COOLING COIL PEAK Peaked at Time: Mo/Hr: 6 / 14 Outside Air: OADB/WB/HR: 94 / 75 / 97 Space Plenum Net Sens. + Lat. Sens. + Lat Total Btu/h Btu/h Btu/h Envelope Loads Skylite Solar 0 0 0 Skylite Cond 0 0 0 Percent Of Total 0 0 CLG SPACE PEAK Mo/Hr: Sum of OADB: Peaks Space Percent Sensible Of Total Btu/h (%) 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 38 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 Percent Of Total 0.00 0.00 TEMPERATURES Cooling SADB 54.0 Ra Plenum 84.3 Return 75.0 RetiOA 74.7 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 68.0 65.3 68.0 68.0 0.0 0.0 0.0 Roof Cond 0 7,106 7,106 17 0 0 Roof Cond 0 2.087 22.79 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Diffuser 1,570 1,570 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0 0 0.00 0.00 Terminal 1,570 1,570 Floor 0 0 0 0 0 0 0 0 0 Floor Adjacent Floor 0 0 0 Main Fan 1,570 1,570 Adjacent Floor 0 0 Sec Fan 0 0 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sub Total =_> 0 7,106 7,106 17 0 0 Sub Total =_> 0 2.087 22.79 Nom Vent 275 275 AHU Vent 275 275 Internal Loads Internal Loads Infil 0 0 Lights 8,839 0 8,839 21 8,839 24 Lights 8,839 8,839 96.52 MinStop/Rh 0 0 People 10,800 0 10,800 26 6,000 16 People 6,000 6.000 65.52 Return 1,570 1,570 Misc 14,683 0 14,683 35 14,683 40 Misc 14,683 14,683 160.33 Exhaust 275 275 Sub Total =_> 34,322 0 34,322 82 29,522 81 Sub Total =_> 297522 29,522 322.36 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 7,106 7,106 0 0 7,106 19 Ceiling Load 2,087 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 204 0 0 0 Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 0 0.00 ENGINEERING CKS Exhaust Heat 0 0 0 OA Preheat Diff. 9.158 100.00 Cooling Heating Sup. Fan Heat 302 1 RA Preheat Diff. 27,435 299.57 OA 17.5 17.5 Rat. Fan Heat 0 0 0 Additional Reheat 0 0.00 cfmlft' 0.65 0.65 Duct Heat Pkup Underflr Sup Ht Pkup 0 0 0 0 0 Underflr Sup Ht Pkup 0 0.00 cfmfton 289.57 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'tton 444.13 Btu/hrft' 27.02 3.80 Grand Total =_> 41,427 0 41,934 100.00 36,627 100.00 Grand Total ==> 27,435 9,158 100.00 No. People 24 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBIWB/HR Leave DB/WB/HR ton MBh MBh cfm F °F gr/lb F °F grllb Main Clg 3.5 41.9 36.3 1,570 74.7 61.0 58.8 53.8 51.6 53.6 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 09 Opt Vent 1.9 23.1 11.5 275 91.5 77.6 121.8 54.0 53.9 62.3 Total 5.4 65.1 AREAS Gross Total Glass w Floor 2,408 Part 0 Int Door 0 ExFlr 0 Roof 27408 0 0 wall 0 0 0 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm F F Main Htg 0.0 0 0.0 0.0 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 9.2 275 38.0 68.01 Total 9.2 Project Name: CLX TRACE® 700 v6.3.3 calculated at 11:38 AM on 01/16/2018 Dataset Name: 17-1213.TRC Alternative - 1 System Checksums Report Page 5 of 8 System - 006 COOLING COIL PEAK Peaked at Time: Mo/Hr: 6 / 17 Outside Air: OADB/WB/HR: 93 / 75 / 101 Space Plenum Net Percent Sens. + Lat Sens. + Let Total Of Total Btu/h Btu/h Btu/h (%) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 8,824 8,824 14 Glass Solar 12,477 0 12,477 19 Glass/Door Cond 105 0 1,065 2 Wall Cond 1,954 1,641 3,594 6 Partition/Door 4,828 4,828 8 Floor 0 0 0 Adjacent Floor 0 0 0 0 Infiltration 0 0 0 Sub Total =_> 20,323 10,465 30,788 48 Internal Loads Lights 14,627 0 14,627 23 People 8.766 0 8.766 14 Misc 8.513 0 8.513 13 Sub Total==> 31,906 0 31,906 50 Ceiling Load 10,162 10,162 0 0 Ventilation Load 0 0 1,071 2 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0 Exhaust Heat 0 0 0 Sup. Fan Heat 483 1 Ret Fan Heat 0 0 0 Duct Heat Pkup 0 0 0 Underflr Sup Ht Pkup 0 0 Supply Air Leakage 0 0 0 Grand Total ==> 62,391 303 64,248 100.00 Total Capacity ton MBh Main Cig 5.4 64.3 Aux Cig 0.0 0.0 Opt Vent 2.3 27.9 Total 7.7 92.1 System Checksums By RGD CLG SPACE PEAK Mo/Hr: Sum of OADB: Peaks Space Percent Sensible Of Total Btu/h Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 Roof Cond 12,438 21 Glass Solar 1,089 2 Glass/Door Cond 1,914 3 Wall Cond 4,828 8 Partition/Door 0 0 Floor 0 0 Adjacent Floor 0 0 Infiltration 20,269 35 Sub Total Internal Loads 14,627 25 Lights 4,870 8 People 8,513 15 Misc 28,010 48 Sub Total ==> 10,229 17 Ceiling Load 0 0 Ventilation Load 0 0 Adj Air Trans Heat Ov/Undr Sizing 0 0 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat Underfir Sup Ht Pkup Supply Air Leakage 58,508 100.00 Grand Total ==> COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DS/WB/HR Leave DB/WB/HR MBh cfm F °F gr/Ib F °F gr/lb 58.6 2,508 74.7 60.3 55.5 53.8 51.2 52.0 0.0 0 0.0 0.0 0.0 0.0 0,0 0.0 13.8 331 91.5 77.6 121.8 54.0 53.9 62.3 HEATING COIL PEAK Mo/Hr: Heating Design OADB: 38 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu/h 0 0 0.00 0 0 0 00 0 3,175 28.76 0 0 0.00 2,121 2,121 19.21 2,196 4,412 39.97 10,340 10,340 93.68 0 0 0.00 0 0 0 0 0 0.00 14,657 20,047 181.63 14,627 14.627-132,52 4,870 4,870 -44.12 8,513 8.513 -77.13 28,010 28,010-253.78 5,390 0 0.00 0 0 0.00 0 0 0 0 0 0.00 0 0,00 11.037 100.00 7,963 72,15 0 0.00 0 0.00 0 0,00 7,963-11,037 100.00 AREAS Gross Total Glass ft' Floor 3,896 Part 888 Int Door 0 ExFIr 0 Roof 3.896 0 0 Wall 1.833 140 8 Ext Door 0 0 0 Single Zone TEMPERATURES Cooling Heating SADB 54.0 68.0 Ra Plenum 83.2 63.6 Return 75.0 68.0 ReVOA 74.7 68.0 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.1 0.0 AIRFLOWS Cooling Heating Diffuser 2,508 2,508 Terminal 2,508 2,508 Main Fan 2,508 2,508 Sec Fan 0 0 Nom Vent 331 331 AHU Vent 331 331 Infil 0 0 MinStop/Rh 0 0 Return 2,508 2,508 Exhaust 331 331 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating 13.2 13.2 cfmtft' 0.64 0,64 cfm/ton 326.68 ft'/ton 507.50 Btu/hr-ft' 23.65 -2.83 No. People 19 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm F Main Htg 0.0 0 0.0 Aux Htg 0.0 0 0.0 Preheat 0.0 0 0.0 Humidif 0.0 0 0.0 Opt Vent 11,0 331 38.0 Total 11.0 Project Name: CLX TRACED 700 v6.3.3 calculated at 11:38 AM on 01/16/2018 Dataset Name: 17-1213.TRC Alternative - 1 System Checksums Report Page 6 of 8 System - 007 COOLING COIL PEAK Peaked at Time: Mo/Hr: 6 / 14 Outside Air: OADBfWB/HR: 94 / 75 / 97 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h 1) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 289 289 19 Glass Solar 0 0 0 0 Glass/Door Cond 0 0 0 0 Wall Cond 0 0 0 0 Partition/Door 0 0 0 Floor 0 0 0 Adjacent Floor 0 0 0 0 Infiltration 0 0 0 Sub Total ==> 0 289 289 19 Internal Loads Lights 502 0 502 33 People 0 0 0 0 Misc 669 0 669 44 Sub Total ==> 1,171 0 1,171 77 Ceiling Load 289 289 0 0 Ventilation Load 0 0 40 3 Adj Air Trans Heat 0 0 0 Dehumid, Ov Sizing 0 0 Ov/Undr Sizing 0 0 0 Exhaust Heat 0 0 0 Sup. Fan Heat 12 1 ReL Fan Heat 0 0 0 Duct Heat Pkup 0 0 0 Underfir Sup Hit Pkup 0 0 Supply Air Leakage 0 0 0 Grand Total==> 1,460 0 1,512 100.00 Total Capacity ton MBh Main CIg 0.1 1.5 Aux CIg 0.0 0.0 Opt Vent 0.0 0.5 Total 0.2 2.0 System Checksums By RGD CLG SPACE PEAK Mo/Hr: Sum of OADB:Peaks Space Percent Sensible Of Total Btu/h Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 Roof Cond 0 0 Glass Solar 0 0 Glass/Door Cond 0 0 Wall Cond 0 0 Partition/Door 0 0 Floor 0 0 Adjacent Floor 0 0 Infiltration 0 0 Sub Total ==> Internal Loads 502 34 Lights 0 0 People 669 46 Misc 1,171 80 Sub Total ==> 289 20 Ceiling Load 0 0 Ventilation Load 0 0 Adj Air Trans Heat Ov/Undr Sizing 0 0 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat Underfir Sup Ht Pkup Supply Air Leakage 1,460 100.00 Grand Total ==> COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB/HR Leave DBAIVB/HR MBh cfm F -F grflb F `F gr/ib 1.5 63 74.8 59.2 50.6 53.8 50.4 49.2 0.0 0 0.0 0.0 0.0 0.0 0.0 0,0 0.2 6 91.5 77.6 121.8 54.0 53.9 62,3 HEATING COIL PEAK Mo/Hr: Heating Design OADB: 38 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu/h 0 0 0.00 0 0 0,00 0 85 43.35 0 0 0.00 0 0 0,00 0 0 0.00 0 0 0.00 0 0 0,00 0 0 0 0 0 0.00 0 85 43,35 502 502 256.05 0 0 0.00 669 669 341.41 1,171 1,171 597,46 85 0 0,00 0 0 0.00 0 0 0 0 0 0.00 0 0.00 196 100.02 1,086 554.09 0 0.00 0 0.00 0 0.00 1,086 -196 100.00 AREAS Gross Total Glass ff' Floor 98 Part 0 Int Door 0 ExFir 0 Roof 98 0 0 wall 0 0 0 Ext Door 0 0 0 Single Zone TEMPERATURES Cooling Heating SADB 54.0 68.0 Ra Plenum 84,3 65.3 Return 75,0 68,0 Ret/OA 74.8 68.0 Fn MtrTD 0.0 0.0 Fn BldTD 0.0 0,0 Fn Frict 0.1 0.0 AIRFLOWS Cooling Heating Diffuser 63 63 Terminal 63 63 Main Fan 63 63 Sec Fan 0 0 Nom Vent 6 6 AHU Vent 6 6 Infil 0 0 MinStop/Rh 0 0 Return 63 63 Exhaust 6 6 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating CA 9.4 9.4 cfm/ft, 0.64 0.64 cfm/ton 374.22 ft'tton 586.07 Btu/haft' 20.48 -2,00 No. People 0 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh chn F Main Htg 0.0 0 0.0 Aux Htg 0.0 0 0.0 Preheat 0,0 0 0.0 Humidif 0.0 0 0.0 Opt Vent 0.2 6 38.0 Total 0.2 Project Name: CLX TRACED 700 v6.3.3 calculated at 11:38 AM on 01/16/2018 Dataset Name: 17-1213,TRC Alternative - 1 System Checksums Report Page 7 of 8 System Checksums By RGD System - 008 Single Zone COOLING COIL PEAK Peaked at Time: Mo/Hr: 6 / 17 Outside Air: OADB/WB/HR: 93 / 75 / 101 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h {%) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 6,230 6,230 13 CLG SPACE PEAK Mo/Hr: Sum of OADB: Peaks Space Percent Sensible Of Total Btu/h (%) 0 0 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond Roof Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 38 Space Peak Coil Peak Space Sens Tot Sens Btu/h Btu/h 0 0 0 0 0 -2,401 Percent Of Total 0.00 0.00 10.12 TEMPERATURES Cooling SADB 54.0 Ra Plenum 82.5 Return 75.0 Ret/OA 74.8 Fn MtrTD 0.0 Fn BIdTD 0.0 Fn Frict 0.1 Heating 77.2 63.9 68.0 68.0 0.0 0.0 0.0 Glass Solar 8,513 0 8,513 17 8,513 20 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 760 0 760 2 760 2 Glass/Door Cond 1,272 1,272 5.36 Cooling Heating Wall Cond 1,219 1,077 2,296 5 1,220 3 Wall Cond 1,327 2,681 11.30 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 1,850 1,850 Floor 0 0 0 0 0 Floor 0 0 0,00 Terminal 1,850 1,850 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0 Main Fan 11850 1,850 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 10,492 7,307 17,799 36 10,493 24 Sub Total =_> 2,600 6,354 26.79 Nom Vent 146 146 AHU Vent 146 146 Internal Loads Internal Loads Infil 0 0 Lights 10,561 0 10,561 22 10,561 24 Lights 10,561 10,561 44.52 MinStop/Rh 0 0 People 101800 0 10,800 22 6,000 14 People 6,000 61000 25.29 Return 1,850 1,850 Misc 9,147 0 9,147 19 9,147 21 Misc 9,147 9,147 38.56 Exhaust 146 146 Sub Total =_> 30,508 0 30,508 62 25,708 60 Sub Total ==> 25708 25,708 108.38 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 6,955 6.955 0 0 6,953 16 Ceiling Load 3,754 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 250 1 0 0 Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 38,216 38,216 161.10 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 0 0.00 ENGINEERING CKS Exhaust Heat 0 0 0 OA Preheat Diff, 4,859 20.48 Sup. Fan Heat 356 1 RA Preheat Diff. 0 0.00 Cooling Heating Ret, Fan Heat 0 0 0 Additional Reheat 0 0.00 OA 7.9 7.9 Duct Heat Pkup 0 0 0 cf n/ft' 0.64 0,64 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfmtton 362.79 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 Wlton 571.32 Btulhr•ft' 21.00 1.89 Grand Total ==> 47,955 352 48,913 100.00 43,155 100.00 Grand Total ==> 18,862 23,721 100.00 No. People 24 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DBANBIHR ton MBh MBh cfm F °F gr/lb F °F gr/lb Main Cig 4.1 48.9 43.5 1,850 74.8 60.7 57.1 53.8 51.3 52.6 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 1.0 12.3 6.1 146 91.5 77.6 121.8 54.0 53.9 62.3 Total 5.1 61.2 Project Name: CLX Dataset Name: 17-1213.TRC AREAS Gross Total Glass ft' Floor 2.913 Part 0 Int Door 0 ExFlr 0 Roof 2,913 0 0 Wall 1,107 84 8 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg'' MBh cfm F F' Main Htg 0.6 1,850 76.9 77.2' Aux Htg 0.0 0 0.0 0.0', Preheat 0.0 0 0.0 0.0' Humidif 0.0 0 0.0 0.0'. Opt Vent 4.9 146 38.0 68,0i, Total 5.5 TRACEQ 700 v6.3.3 calculated at 11:38 AM on 01/16/2018 Alternative - 1 System Checksums Report Page 8 of 8 tFY OF S NFORD Building & Fire Prevention Division COMMERCIAL PERMIT GUIDELINES All permit application packages must be complete prior to acceptance. You must check each box to the left or indicate n/a on this submittal. A complete application package shall include the following: V Building Permit Application completed, signed and notarized. Application must include correct address and complete parcel I.D. number. Copy of a contract, signed by the contractor and property owner, indicating the documented construction value X Copy of the contractor's license issued by the State of Florida (if contractor is applicant). V A site specific notarized power of attorney shall be required from the licensed contractor if he/she appoints an employee of his/her company to sign the permit application as the contractor. D Certificate of insurance indicating worker's compensation insurance coverage and naming the City of Sanford as certificate holder, or a copy of a worker's compensation exemption issued by the State of Florida (must be submitted with each application if contractor is the applicant). Owner Builder Statement / Affidavit (if owner is applicant). Must be signed in person at the Building Department) LLC's do not qualify for the Owner Builder exception per Florida Statute L-1 Approval letter from sanitary sewer provider (if other than the City of Sanford), 14A Copy of the onsitc sewage disposal system construction permit issued by Seminole County Health Department for new or existing septic systems, grease interceptors, etc. (if applicable). Seminole County Impact Fee Statement. 0 Five (5) sets signed and scaled building construction plans. f,Y" A Two (2) sets signed and scaled site development plans approved by City of Sanford Planning & Development Services Department. t-,tt Po Letter from Planning & Development Services agreeing to submittal of plan without development plan approval. This is at the developer's risk, 10 Two (2) sets signed and sealed floor and roof truss engineering. Eh Completed and signed Statewide Product Approval Specification Form, 11 Two (2) copies ofthe manufacturer's installation instructions for the following products: windows, doors, roofing materials, j4ngmcered4um4,k4)rqducts, gJasrbiorks, Three (3) sets of completed and signed energy calculations (signed/sealed if required by Florida Statute or code). State of Florida Division of Hotel and Restaurant approval (if applicable). A- Florida Department of Environmental Protection Notice of Asbestos Renovation or Demolition (if applicable). AJ State of Florida Notification on Gas Tanks (if applicable). Floodplain development application completed and signed if any portion of the property is in a flood hazard area as identified on the most current flood insurance rate map. THE BUILDING CONSTRUCTION DOCUMENTS MUST INCLUDE, AT A MINIMUM, THE FOLLOWING: SITE PLAN (Development j2lan includes additional re uirements) All parking and accessible routes Accessible parking space(s) and signage details JR Accessible entrances 4 Accessible ramps, handrails, guardrails, curb cuts and details E,'/Pcave - August /, 2017 Page I ol'7 All required building exits accessible (not less than 60% if all are not required exits) El Areas of rescue assistance I`Vwsi V Accessible signage El Fire access 1-1 Vehicle loading L, Driving/turning radius 6a Fire hydrant/water supply/post indicator valve (PIV) Ej Vk Location of septic systems (if applicable) Setbacks/lire separation (assumed property lines) Utility lines (water, sewer, irrigation Meters and backflow devices BUILDING PLAN 1AV Construction documents shall indicate code edition being applied L1 Page size minimum I I" x 17" , 71-1 Plans to minimum 1/4" scale Zl— V 14, All pages numbered and labeled Plans signed/sealed and dated by a Florida Design Professional as applicable Designer information: name, address, registration # on all pages Reference the currently adopted code editions Wind design data required on drawings per FBC 16011.4 to meet 129 mph ultimate design wind speed for risk category I buildings, 139 mph ultimate design wind speed for risk category 11 buildings and 149 mph ultimate design wind speed for risk category III and IV buildings Ultimate design wind speed (Volt) I It--- Nominal design wind speed (Vasd) Risk category Exposure category Enclosure classification Internal pressure coefficient Component and cladding design wind pressures in terms o f psf 9 Structural Calculations, if necessary Ll Threshold Inspection Plan (for threshold buildings) I K All areas dimensioned and use noted r Corridors 11 Shafts and elevator hoistways Li Stair location/guardrails/handrails Ij Partition denotations and schedule V Door locations, sizes, door and hardware schedule V Window locations, sizes and schedule IX0 Tempered glass locations 44 *6& V Attic ventilation and access A Air barrier requirements g 0.. 01 Interior finish ratings and schedule Poet, V Light and ventilation IY' Sanitation n Elevators Escalators Lifts F1 Roof coverings Construction type design criteria: El Type of construction denoted (per table 503) Effective: Augiat 1, 2017 Page 2 of 7 Occupancy group classification denoted for building and rooms/areas N Gross square footage — Net square footage calculations N Building height X Percentage of exterior openings calculations Classification of hazard of contents (if applicable) Structural Design Criteria: Ultimate design wind speed (Vult) Nominal design wind speed (Vasil) Risk category Exposure category VEnclosure classification V/0 Internal pressure coefficient Component and cladding design wind pressures in terms of psf 1-1 Structural Calculations, if necessary Floor loads — psf Stair loads — psf Roof loads — psf Balcony loads — psf V Corridor loads — psf V Storage loads — psf Materials to be reviewed shall at a minimum include the following: ul At Wood / grade — species X Steel / type - grade N Aluminum X Concrete X Plastic IN Glass NA Masonry A Gypsum board and plaster a Insulating (mechanical) A Roofing Insulation N A Alternate materials Structural: I Signed and seated soil report with a positive conclusion required A Compaction requirements ---. (Ir VFoundation locations, dimensions and depth specified V Foundation denotations, schedules and details Reinforcing steel, amount, size, grade, spacing, and lap specified Footing dowel locations Maximum filled cell spacing n Embedment's L/ Stab thickness and reinforcement A Vapor barrier N Termite protection El Relieving arch steel details at pipe penetrations 1 Brick ledge detail including flashing and weep hole size and spacing f, Building materials used F1 Lintel locations, denotations and schedule N Exterior and interior structural wall sections lixtive: August /, 2017 Page 3 (f-7 I/ Columns 1 Tie beams E' Structural steel size, type, connections A Framing details and fastening I_ 4 Load path connectors 6 Floor deck and fastening A Wall sheathing and fastening V Roof deck and fastening Ij 1 Stair construction IN Window and door details, including design pressure of openings A Fastening details for windows and doors, (type, length, and quantity) U Exterior mounted mechanical units fastening methods to meet wind load A Roof and floor framing, truss layout, connector schedule Fire Protection Requirements: 1-Y, Fire separation requirements for corridors, elevators, stairways, floors & shafts IX Occupancy separation requirements fN A Tenant separation requirements 11 Fire resistant protection details for type of construction N Rated requirements for walls, floor -ceiling and roof -ceiling assemblies N Design numbers and details for all rated assemblies X Design numbers and details for all rated penetrations N Rated door and hardware schedules FX Fire blocking and draft stopping INA Calculated fire resistance IN Interior finishes (flame spread/smoke development) Life Safety: Ix Occupant load calculations and egress capacities f_X Special occupancy requirements Egress plan Number of exits Capacity of exits IN Arrangement of exits IX Travel distance to exits/common path of travel a Stairs construction/geometry and protection ON Horizontal exits/exit passageways CX Illumination of exits Exit signs Ix Emergency lighting EN, A Enclosures 1X Handrails NA Guardrails INN Ramps L)NA Early warning systems schematic NA Smoke control systems schematic NA Stair pressurization systems schematic DI Extinguishing requirements NA Areas of rescue assistance Accessibility Building: 11 Door sizes, hardware schedule N Vertical accessibility Qfi?cti ve August 1, 2017 Page 4 of 7 I J Accessible route dimensions F] Maneuvering clearances 0( Hi-Lo drinking fountain N Equipment clear floor space/reach ranges El Areas of rescue assistance 0 Signage L1 ATM machines Accessibility Restrooms/Bathrooms: LN Turning radius LX Required floor space for fixtures N Fixture and equipment mounting dimensions r ;A Adaptability Accessible requirements for special occupancies in addition to general requirements will also be reviewed. PLUMBING PLAN V-T Plumbing plans submitted V Piping materials V Piping supports Determine minimum plumbing fixtures required based on occupant load calculated per FBC 1004 Water distribution diagram Water hammer arrestors V Plumbing drain, waste and vent riser diagram U Grease trap detail Grease trap Health Dept, report on existing F'] Interceptors Roof drains/calculations for flat roofs Backflow prevention F1 Medical gas U Oxygen systems 11 Environmental requirements Water Heaters: J T & P drain N Air gap VPan drain U Thermal expansion device I-] Heat traps L] Mounting platform GAS PLAN 1-1 Type of gas F1 Gas pressure U Appliances schedule and BTU's FJ Chimneys and Vents 0 Combustion air 171 L.P tank size and location (above or below grade) U Protection requirements Gas Riser Diagram: 11 Pipe type L] Pipe sizing Ef ,fective: August /, 2017 Page 5 of 7 Cl Total developed length U Segment lengths Cl Appliance locations H Shut -offs valves MECHANICAL PLAN V Mechanical plans submitted N/j. Energy calculations Duct systems and sizing Duct work clearances at mechanical room (4" minimum) Duct supports Means for balancing HVAC system Diffusers (size and direction) CFM requirements Ventilation i Combustion air Outdoor air calculations Balanced return air Make-up air Equipment location and working clearances 30" wide by 36" deep, 6' high minimum) N/ Condensate piping and disposal U Required platforms and catwalks Roof mounted equipment (including equipment and curb anchorage) Cyr Details and specifications tvet Equipment sizing calculations Equipment specifications Joint seating methods and product specification Air balance table Rated penetrations - fire damper details and manufacturer's installation instructions Li Means for automatic fan shutdown Kitchen hood, duct plans, fire suppression and specifications Bathroom exhaust systems 0 Special exhaust systems Chimneys, fireplaces and vents Other appliances Cl Boilers Cl Refrigeration N/ Bathroom ventilation U Laboratory ELECTRICAL PLAN 11 Maximum available fault current at service V AIC rating of equipment V Voltage and phase of electrical system Load calculation Electrical service riser diagram indicating overcurrent protection sizes, conductor and conduit types and sizes, number of service disconnecting means, grounding electrode system: bonded to the foundation steel, structural steel, metal piping, size and type, separately derived system or not? (solid neutral or switching) Transformer sizes and types if used Panel schedules and ratings Power plan Panel locations and working clearances by ,fective, August /. 2017 Page 6 of 7 j4 Lighting plan Device legend Wiring methods and materials Feeders and branch circuits, conduit sizes and types Grounding conductors Exit lights Emergency lighting Egress lighting Signage and disconnecting means location U1 Generator type: emergency or standby Remote annunciation Load shed (if necessary) V Required receptacle outlets V GFCl's V Equipment U Special occupancies Emergency systems Communication systems Vr Low voltage FIRE PROTECTIONTIRE SUPPRESSION PLAN U Early warning smoke evacuation and control Sprinkler design criterion (separate permit required) Fire alarm design criterion (separate permit required) r Pre-engineered systems V Riser diagram U Standpipes These guidelines were compiled to assist the applicant in preparing a new commercial permit1plan submittal (Ind may not be complete, The applicant is required to meet all City q/'Sanft,)rd, state, crud federal code requirements. Please be aware that a separate permit is required for any ire sprinkler system sand fire alarm system. All site related signs, fences, hardscape features, guard1hand rails, free standing walls, retaining walls, canopies, accessory structures, site electrical and lighting satellite dishes, dumpster enclosures, irrigation systems, lift stations, and any demolition qI'structures. t4kcfive, 4ugust /, 2017 Page 7 o/ 7 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: January 22, 2018 I hereby name and appoint: James Feaster and Dawn Moss, Steve Corrow and Robert Lacey an agent of- Gomez Construction Company Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): N The specific permit and application for work located at: 361 South White Cedar Rd Sanford FL 32771 0 Expiration Date for This Limited Power of Attorney:_ Project Completion License Holder Name: Orlando Gomez State License Number: CGCO05258 Signature of License Holder: STATE OF FLORIDA COUNTY OF I(A The foregoing instrument was acknowledged before me this ' DU - day of a W)(Iown200_Ly_, by - C-I( who is w ally k to me or n who has produced as identification and who did (did not) take an oath. Notary Seal) AiL BAMM MORENO 4MY COMMMION # GO 138732 A-` EVIRE&AV*28,2021 BftWThruN0"P4kUm*wrftm Rev. 08. 12) T Print or type name Notary Public - State of Pg i a Commission No. -1 - My Commission Expires: Nw eZ 9 Florida Building Code, Sixth Edition (2017) - Energy Conservation EnergyGauge Summit@ Fla/Gam-2017, Effective Date: Dec 31, 2017 IECC 2015 - Total Building Performance Compliance Option Check List Applications for compliance with the Florida Building Code, Energy Conservation shall include: This Checklist geThe full compliance report generated by the software that contains the project summary, compliance summary, certifications and detailed component compliance reports. The compliance report must include the full input report generated by the software as contigous part of the compliance report. Boxes appropriately checked in the Mandatory Section of the complaince report. PEAMIT EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page I of 34 PROJECT SUMMARY Short Desc: CLX Owner: Addressl: 301 South White Cedar Road Address2: Description: CLX Design Building City: State: Zip: Type. Office Class: Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Conditioned Area: 13303 SF Conditioned & UnConditioned Area: No of Stories: I Area entered from Plans Permit No: Max Tonnage If different, write in: Building Rotation: 90 Deg Clockwise. Walls & windows will be rotated accordingly Sanford Florida 32771 New Finished building 19065 SF 19065 SF I EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 2 of 34 Compliance Summary Component Design Criteria Result Gross Energy Cost (in $) 9,195.0 9,757.0 PASSED LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES PASSES PASSES No Entry PASSES PASSES Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit} Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 3 of 34 41 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Robert G. Davenport PE Date: Building Official: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Allen G. Liang PE Reg No: 5454/54049 Lighting Designer: Allen G. Liang PE Reg No: 5454 /54049 Mechanical Designer: Robert G. Davenport PE Reg No: 5454 / 31932 Plumbing Designer: Robert G. Davenport PE Reg No: 5454/31932 Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. No.54049 R - N Q NALIfiteaseW RGD, CONSULTING ENGINEERS MECHANICAL I ELECTRICAL I PLUMBING I FIRE PROTECTION I STRUCTURAL Nvimirgdengineemcom 2151 SOUTH ALT. AM SUITE 2000 JUPITER. FL 334-17 - (561)743-0165 cEr,T OF AuTm U54 1932 EnergyGauge Summit} Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 4 of 34 Project: CLX Title: CLX Design Building Type: Office WEA File: FL ORLANDO SANFORD AIRPORTAW) Building End Uses 1) Proposed 2) Baseline 589.80 735.00 Total 9,195 11,4 79 ELECTRICITY(MBlulkWh4) 589.80 735.00 172843 215362 9,195 11,479 AREA LIGHTS 122.40 185.20 35871 54271 1,908 2,893 MISC EQUIPMT 184.40 184.40 54030 54030 2,874 2,880 PUMPS & MISC 0.70 0.60 192 170 10 9 SPACE COOL 124.60 175.90 36518 51546 1,943 2,747 SPACE HEAT 4.40 8.60 1301 2515 69 134 VENT FANS 153.30 180.30 44931 52830 2,390 2,816 Credits Applied: None ASSES Passing Criteria = 9757 Design (including any credits) = 9195 Passing requires Proposed Building cost to be at most 85% of Baseline cost. This Proposed Building is at 80.1% EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 5 of 34 Project: CLX Title: CLX Design Building Type: Office WEA File: FL ORLANDO SANFORD AIRPORT.tm3) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP NV/Unit) or No. of Units W) (W) Sgft or ft) Ext Light 1 Entry Canopies Yes 0.40 172.5 69 69 Ext Light 2 Other (doors) than main entries Yes 20.00 3.0 60 168 Ext Light 3 Main entries Yes 30.00 16.0 480 84 Tradable Surfaces: 321 (W) Allowance for Tradable: 1359 (W) PASSES All External Lighting: 321 (W) Complicance check includes a excess/Base allowance of 750.00(W) EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 6 of 34 N D v Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option Check List Applications for compliance with the Florida Building Code, Energy Conservation shall include: Ee This Checklist The full mmp|iance report generated bythe software that contains the project aummury` comp|iunoosummucy,certifications and detailed nomponcntuomp\iuooc reports. Thouomp| iuocc mportmuot include the Fu|i input report generated by the software as onnhgnuopart nfthe onmp|iouocreport, L_J Boxes appropriately checked in the Mandatory Section of the cornplaince report. PERMIT Energy600geSommit@Fla&om2017. TAM 017-1.0Compliant Software. Effective Date: Dec 31.017 Florida Building Code, Sixth Edition (2017) Energy Conservation |ECC2015'Total Building Performance Compliance Option 1/23/2018 Page \"[ 34 PROJECT SUMMARY Short Desc: Cl_X Owner: Addressl: 301 South White Cedar Road Add ress2: Description: CLX Design Building City: State: zip- Type: Office Class: Jurisdiction: SANFORD, SE,MINOLE COUNTY, FI, (691500) Conditioned Area: 13303 SF Conditioned & I'nConditioned Area: No of Stories: I Area entered from Plans Permit No: Max `Tonnage If different, write in: Building Rotation: 90 Deg Clockv ise. Walls ck 4 indows will be rotated accordingly Sanford Florida 32771 New Finished building 19065 SF 19065 SF II EnergyGauge Summit@ Fla/Com-2017, TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/201 8 Page 2 of 34 W Component Design Criteria Result Gross Energy Cost (in $) 9,195.0 9.757.0 PASSED LIGHTING CONTROLS EXTERNAL LIGHTING FIVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES PASSES PASSES No Entry PASSES PASSES Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit@ Fla/Com-2017, TAM 2017-1.0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/2312018 Page 3 of 34 CERTIFICATIONS hereby certify that the plans and specifications covered bYthis calculation are incompliance with the Florida Energy Code PnpnmdRx: Robert GDu`vnpvxPC gu{Niue(xffliuia|: Date: u* u: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner xmuo Dvu: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida Energy Efficiency Code Architect: RegNo: Gleo*bx Du,igmc Allen O.Lian«Pc Reg No: 5*54o4049 UgbhugDesignuc Allen O.||xoePF Reg No: 5454/54049 w1udmuiudDesigner: Robert U.Vvvcnp^nPC Reg No: 5454/31932 OSignature isrequired where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained onsigned/sealed plans. omo"" Poo RCj1U CONSULTING ENGINEERS MECH AN ICAL I ELICVRICAL |," mmw^|*vn"ounvw|vvvC, mm° EnmgyGauge8ummit®RFla/Com-2O17.TAM 2017-|0Compliant Software. Effective Date: Dem31 2017 Florida Building Code, Sixth Edition (2O17)- Energy Conservation |ECC2015 Total Building Performance Compliance Option 1/23/2018 Page 4u[34 Project: ('LX title: CLX Design Building Type: Office VVEA File: FL ORLANI)O SANFORD AIRPORTAW) Building End Uses 1) Proposed 2) Baseline Total 589.80 735.00 9,195 11,479 ELECTRICITY(MBtu1kWh1$) 589.80 735.00 172843 215362 9,195 11,479 AREA LIGHTS 122.40 185.20 35871 54271 1, 908 2, 893 MISC EQUIPMT 184.40 184.40 54030 54030 2,874 2,880 PUMPS & MISC 0.70 0.60 192 170 10 9 SPACE COOL 124.60 175.90 36518 51546 1, 943 2, 747 SPACE HEAT 4.40 8.60 1301 2515 69 134 VENT FANS 153.30 180.30 44931 52830 2,390 2,816 Credits Applied: None PASSES Passing Criteria = 9757 Design (including any credits) = 9195 Passing requires Proposed Building cost to be at most 85% of Baseline cost. This Proposed Building is at 80.1% EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/2312018 Page 5 of 34 1 /23/2018 Project: CLX I-itle: CLX Design Building Type: office WF.A File: FL ORLANDO SANFORD AIRPOR"I'.tm3) External Lighting Compliance Description ('ategory 'Tradable? Allowance Area or Length ELPA Ct,P W/Unit) or No. of Units N3'} (XV) Sgft or ft) Ext Light t Entry Canopies Yes 0.40 172.5 69 69 Ext Light 2 Other (doors) than main entries Yes 20,00 3.0 60 168 Ext Light 3 Main entries Yes 30,00 16.0 480 84 Tradable Surfaces: 321 (W) Allowance for Tradable: 1359 (W) PASSES All External Lighting: 321 (W) Complicance check includes a excess/Base allowance of 750.00(W) EnergyGauge Summit@ FlalCom-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option Page 6 of 34 Project: CLX Title: CLX Design Building Typc: Office WEA File: FL ORLANI)O SANFORD AIRPORI'.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID sq.ft) CP CP ante 101 OFFICE; KW 17 Olficc - Enclosed 365 2 1 PASSES IOI,A EXEC CONE 15 Conference/meeting (Multiple 239 2 1 PASSES Functions) 107 OFFICE 17 Office - Enclosed 124 1 1 PASSES 108 OI`I'ICE: Ili 17 Office - 11,11closed 103 1 1 PASSES 109 OFFICE Si 17 Office - Enclosed 102 1 1 PASSES 110 OFFICE 17 Office - Enclosed 99 1 1 P ASSEES I I 1 OFFICE:: 17 Office - Enclosed 101 1 l PASSES 112 OFFICE 17 Office - Enclosed 97 1 1 PASSES 113 CONF EUNCE, 15 Couterence/meeting (lvtultiple 175 2 1 PASSES Functions) 001 CORRIDOR 5 Corridor 293 1 1 PASSES 002 CORRIDOR 5 Corridor 135 1 PASSES 102 OI 1'ICE MS 17 Otfice - Enclosed 301 1 1 PASSES 103 OFFICE 1111 17 Office - F,nclosed 301 1 1 PASSES 104 S FORAGE 3 Storage & Warehouse - Bulky 136 I l PASSES Active Storage 114 OFFICE KI, 17 Office - Enclosed 213 1 PASSES 115 0FE`ICE 17 Office - Enclosed 151 1 1 PASSES 116 RR 6 Toilet and Washroom 57 1 1 PASSES 118 RR 6 `Toilet and Washroom 57 1 1 PASSES 105 ENTRY 12 Lobby ((general) - Reception and 383 l 1 PASSES Waiting 106 MULTI -USE 14 Classroom/Lecture Hall 554 1 1 PASSES 120 OPEN OFFICE_, 17 Office - Enclosed 2,028 1 I PASSES 122 RR 6 'Foilet and Washroom 64 1 1 PASSES 123 RR 6 "Foilet and Washroom 65 1 1 PASSES 124 RR 6 Toilet and Washroom 204 1 1 PASSES 120A S"FORAGE, 3 Storage & Warehouse - Bulky 16 1 1 PASSES Active Storage 127 TRAINING 17 Office - Enclosed 1.998 1 PASSES 127A'I`RAININ6 17 Office - Fnclosed 1,434 1 1 PASSES 130 BREAK ROOiAt 17 Office - Enclosed 341 I 1 PASSES 131 OFFICE, 17 Officc - Enclosed 123 1 1 PASSEES 119 SERVER I Evlectrical Mechanical Equipment 98 1 l PASSES Room - Gcneral 121 OPEN OLjFIC:E? 17 Office - Enclosed 2,527 2 2 PASSES 125 VFS'E' 5 Corridor 72 1 1 PASSES 126 RR 6 Toilet and Washroom 135 1 1 PASSES 128 RISER I Electrical vtechanicat Equipment 20 1 1 PASSES Room - General 121A STORAGE 3 Storage & Warehouse - Bulky 20 1 1 PASSES Active Storage 132 CLOSET 3 Storage & Warehouse -Bulky 139 1 1 PASSES Active Storage 117 NiF.CH i Electrical Mechanical Equipment 31 1 1 PASSEES Room - General EnergyGauge Summit® Fla(Com-2017. TAM 2017-1.0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 7 of 34 W7arehouse 2 Storage & Warehouse - Inactive 5,762 3 3 rkSSE'S Storage I'rO/oIOSpl I Electrical Mechanical Equipment I I I PASSES Room - (general PrOZo I I Sp I I Electrical Mechanical Equipment I I I PASSES Room - (Jenerat I PASSES I EnergyGauge Summit@ Fla/Com-2017, TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 8 o('34 23/2o0 Project: CLX Fitle: CLX Design Building I'vpc: Office System Report Compliance AHIJ/CLJ I System I Constant Volume Air Cooled No. of Units Cooling C ipacity AtILJ/CIJ 2 System 2 Constant Volume Air Cooled No. of Units Component ttcgorN Capacity Design E IT Design WIN Comp - Cooling Systern Air Conditioners Air Cooled 35900 17.25 13.00 8.00 PASSES Cooling Capacity S\stern -SLIPPI Constant Volume AHU/CU 3 System 3 Constant Volume Air Cooled No. of Units Cooling System Air Conditioners Air Cooled 18400 17.00 13.00 8.00 PASSES Cooling Capacit System -Supply Coustant VOILUTIC AF[LJ/CU 4 System 2 Constant Volume Air Cooled No. of Units Component Category Capacity Design l"Iff Design WIN Comp- Eff Criteria IPIIN* Criteria Hance Energy8ougeSummit@Fla/Com-20|7.TAM 2N7-10Compliant Software. Effective Date: Dec 31.2017 Florida Building Code, Sixth Edition (2017)'Energy Conservation |ECC2015 Total Building Performance Compliance Option Pzwe9or34 1/23/2018 Cooling System Air Conditioners Air Cooled 35900 17.25 13.00 8.00 PASSES Split System < 65000 13tu/h Cooling Capacity Heating System Electric Furnace 36850 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1400 0.80 0,82 PASSES System -Supply Constant Volume ALIU/CU 5 System 2 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 41900 17.25 13.00 8.00 PASSES Split System < 65000 [3tu/h Cooling Capacity Heating System Electric Furnace 36850 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1570 0.80 0.82 PASSES System -Supply Constant Volume AHU/CC1 System 2 Constant Volume Air Cooled No. of Units 6A Split System < 65000 Btu/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 36700 17.25 13.00 8.00 PASSES Split System < 65000 E3tu/h Cooling Capacity I leating System Electric Furnace 36850 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1435 0.80 0.82 PASSES System -Supply Constant Volume AHU/CU System 2 Constant Volume Air Cooled No. of Units 6B Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 27600 17.00 13.00 8.00 PASSES Split System < 65000 E3tu/h Cooling Capacity Heating System Electric Furnace 24566 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1075 0.80 0.82 PASSES System -Supply Constant Volume EnergyGauge Summit@ Fla/Com-2017, TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option Page 10 of 34 2;/2O|8 AHU/CU 8 System 2 Constant Volume Air Cooled No. of Units Eff Criteria tPlA' Criteria Hance Cooling S sterri Air Conditioners Air Cooled 48900 16.50 13,00 8,00 PASSES Cooling Capacit Heating System E.lectric Furnace 36850 1,00 1.00 PASSES OA- I OA-I Constant Volume Packaged No. of Units System Component CategorN Capacity Design Eff Design 11,111" CORIP- Cooling Capacit AHLJ Ail Ii / CIJ-7 Constant Volume Air Cooled No. of Units Cornponent Category Capacity Design Eff Design lPtIV Conlp- Cooling Systcni Air Conditioners Air Cooled 24000 21 A0 13,00 8.00 PASSES Cooling Capacity PASSES EnorgyGnuge8ummit@Fla/Com-2017,TAM 201z1VCompliant Software. Effective Date: Dec 31'2V17 Florida Building Code, Sixth Edition (2017) Energy Conservation IECC 2015 - Total Building Performance Compliance Option Page i|o[34 23/20N Plant Compliance Description Installed Size Design Nlin Design NI in Category Corrip I None Project: CLX type: Office Water Heater Compliance Description I , ype Category Design Nlin Design Nlax Conip PASSES Project: CLX Fitle: CLX Design Building I'vpc: Office Piping System Compliance SvStenis TJPASSES Enorgy8auVnSummk@ Fla/Cnm-2017.TAM 2017-1.0Compliant Software. Effective Date: Dec 31.2017 Florida Building Code, Sixth Edition (2O17) Energy Conservation |ESC2015'Total Building Performance Compliance Option Page 12vO4 Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department of Energy and Pacific Northwest National Laboratory, Adopted with permission Topic Section Component Description Yes N/A Exempt Insulation C303.2 Envelope Below -grade wall insulation installed per manufacturer's instructions, Insulation C303,2 Envelope Slab edge insulation installed per manufacturer's 0 instructions. Insulation C303,2 Envelope Above -grade wall insulation installed per O'D El manufacturer's instructions. Insulation C402,3 Envelope High-albedo roofs satisfy one of the following: 3-year-aged solar reflectance — 0.55 and thermal emittance — 0,75 or 3-year-aged solar reflectance index — 64.0 Fenestration C402AA Envelope U-factor of opaque doors associated with the building thermal envelope meets requirements. SYSTEM —SPECIFIC C4032121 Mechanical HVAC fan systems at design conditions do not exceed allowable fan system motor nameplate hp SYSTEM —SPECIFIC C403,2,12,2 Mechanical or fan system bhp HVAC fan motors not oversized beyond allowable El ED limits SYSTEM —SPECIFIC C4032.3(8) Table Mechanical Heat Rejection Equipment: Minimum Efficiency Requirement meet those listed in Table C403,2,3(8) HVAC C403Z7 Mechanical Exhaust air energy recovery on systems meeting o Table C403.2 7(1) and C403.2.7(2). SYSTEM —SPECIFIC C403,3 Mechanical Air economizers provided where required, meet El El the requirements for design capacity, control signal, ventilation controls, high -limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation SYSTEM —SPECIFIC C403,3 2 Mechanical Economizer operation will not increase heating ID le energy use during normal operation. SYSTEM —SPECIFIC C403,3 4, Mechanical Water economizers provided where required, C4013A1, meet the requirements for design capacity, C403,3 4,2, maximum pressure drop and integrated C403.3,1 economizer control SYSTEM —SPECIFIC C403AZI Mechanical Three -pipe hydronic systems using a common ie El 0 return for hot and chilled water are not used SYSTEM SPECIFIC C403,4,2,3 1 Mechanical Hydronic heat pump systems connected to a common water loop meet heat rejection and heat SYSTEM —SPECIFIC C403A3.4 Mechanical addition requirements, Open - circuit cooling towers having water cooled chiller systems and multiple or vairable speed condenser pumps, are designed so that tower cells can run in parallel with larger of flow crtiena SYSTEM— SPECIFiC C404,2 Mechanical Service water heating equipment meets efficiency requirements. Wattage C405.3 Interior Lighting Exit signs do not exceed 5 watts per face. 011 Plan Review C 103,2 Envelope Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. EnergyGauge Summit& Fla/Com-2017, TAM 2017-1.0 Compliant Software, Effective Date, Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/ 23/2018 Pane 13 (0'34 Plan Review C 103,2 Mechanical Plans, specifications, and/or calculations provide FJ F] all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering st Plan Review C 103,2 Mechanical Plans, specifications, and/or calculations provide El 1:1 1-1 all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufact Plan Review C103,2 Interior Lighting Plans, specifications, and/or calculations provide El M 11 all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided shoul Plan Review C 103,2 Exterior Lighting Plans, specifications, and/or calculations provide El 1:1 1:1 all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided shout Insulation C4022.5 Envelope Slab edge insulation depth/length. Slab insulation EI M 1:1 extending away from building is covered by pavement or — 10 inches of soil. Insulation C402,2,6 Project Radiant heating systems panels insulated to El 1:1 R-3 5 on face opposite space being heated HVAC C402.2,6 Mechanical Thermally ineffective panel surfaces of sensible El 1-1 1:1 heating panels have insulation — R-3.5. Insulation C402.2.6 Envelope Radiant panels and associated components, 0 1:1 1:1 designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5 Air Leakage C402,57 Envelope Vestibules are installed on all building entrances El 1:1 1:1 Doors have self -closing devices SYSTEM —SPECIFIC C403,2,12 3 Mechanical Fans have efficiency grade (FEG) — 67, The total El El 1:1 efficiency of the fan at the design point of operation — 15% of maximum total efficiency of the fan HVAC C403.213 Mechanical Unenclosed spaces that are heated use only El radiant heat. HVAC C403.2*2 Mechanical Each zone equipped with setback controls using 1:1 El automatic time clock or programmable control system. SYSTEM —SPECIFIC C403,2,4,4 Mechanical Zone isolation devices and controls installed 1:1 El 1-1 where applicable. SYSTEM —SPECIFIC C403.2A,7 Mechanical Fault detection and diagnostics installed with El M M air-cooled Unitary DX units having economizers, SYSTEM —SPECIFIC C403.2.5 Mechanical Hot water boilers supplying heat via one- of El 1:1 1-1 two -pipe systems include outdoor setback control HVAC C403.2,61 Mechanical Demand control ventilation provided for spaces El 1:1 1:1 500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 CfM, SYSTEM —SPECIFIC C403.4.1.1 Mechanical Hydronic and multizone HVAC system controls El M 1:1 areVAV fans driven by mechanical or electrical variable speed drive per Table C403.4. 1, 1, SYSTEM —SPECIFIC C4014,13 Mechanical Reset static pressure setpoint for DDC controlled El 1:1 1:1 VAV boxes reporting to central controller based on the zones requiring the most pressure. SYSTEM —SPECIFIC C403A 2 Mechanical Temperature reset by representative building El 1:1 M loads in pumping systems for chiller and boiler systems >500,000 Stu/h. EnergyGauge Summitti Fla/Com-2017. TAM 2017-1 .0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 14 of 34 SYSTEM —SPECIFIC C403 4,2,3 2 1 Mechanical Closed-circuit cooling tower within heat pump loop have either automatic bypass valve or lower leakage positive closure dampers. Open -circuit tower within heat pump loop have automatic valve to bypass all heat pump water flow around the tower. Open- or cl SYSTEM —SPECIFIC C403,42A Mechanical Hydronic systems greater than 500,000 Btu/h designed for variable fluid flow. SYSTEM —SPECIFIC C403,42,5 Mechanical System turndown requirement met through multiple single -input boilers, one or more modulating boilers, or a combination of single -input and modulating boilers - Boiler input between 1.0 MBtu/h and 5 MBtu1h has 3:1 turndown ratio. boiler input between 5,0 SYSTEM —SPECIFIC C403.4.2.6 Mechanical Chilled water plants with multiple chillers have El 1:1 capability to reduce flow automatically through the chiller plant when a chiller is shut down. Boiler plants with multiple boilers have the capability to reduce flow automatically through the boiler plant SYSTEM —SPECIFIC C403,43. Mechanical Fan systems with motors —7.5 hp associated C403 43 2 with heat rejection equipment to have capability to operate at 2/3 of full -speed and auto speed controls to control the leaving fluid temperature or condensing temp/pressure of heat rejection device SYSTEM —SPECIFIC C403.4*5 Mechanical Multiple zone HVAC systems have supply air temperature reset controls. SYSTEM —SPECIFIC C403,44,6 Mechanical Multiple zone VAV systems with DDC of individual 1-1 zone boxes have static pressure setpoint reset controls. SYSTEM —SPECIFIC C404,21 Mechanical Gas -fired water -heating equipment installed in new buildings: where a singular piece of water -heating equipment — 1.000 kBtu/h serves the entire building, thermal efficiency — 90 Et Where multiple pieces of water -heating equipment serve the building wi SYSTEM —SPECIFIC C404A Mechanical All piping insulated in accordance with section details and Table C 403,2. 10. SYSTEM —SPECIFIC C404 . 5, C404.5.1, Mechanical Heated water supply piping conforms to pipe El n C404.52 length and volume requirements. Refer to section details, SYSTEM —SPECIFIC C404.63 Mechanical Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to — 5 minutes after end of heating cycle, SYSTEM —SPECIFIC C404 7 Mechanical Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the Wattage C405,51 pump upon receiving Exterior Lighting Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Plan Review C405,6 Project Group R-2 dwelling units have separate electrical meters. Plan Review C406 Project Plans, specifications, and/or calculations provide 13 El all information with which compliance can be determined for the additional energy efficiency package options SYSTEM —SPECIFIC C408Z2.2 Mechanical HVAC hydronic heating and cooling coils have means to balance and have pressure test connections. SYSTEM —SPECIFIC C408,2Z2 Mechanical HVAC hydronic heating and cooling coils have means to balance and have pressure test connections. EnergyGauge Summit@ Fla/Com-2017, TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 15 ot'34 Insulation C303.1 Envelope Insulation C303.1 Envelope Fenestration C303.1.3 Envelope Fenestration C303.1.3 Envelope Insulation C303.2, C402 2A Envelope Insulation C303ZII Envelope Insulation C303.21 Envelope Insulation Insulation Insulation C402.1.3 C402.2.2 C402.2.2 Air Leakage C402-5 Air Leakage Air Leakage Air Leakage Air Leakage Air Leakage Air Leakage C402 5 1 C402.5 1.1 C402.5.1.2.1 C402.5 1.2.2 Envelope Envelope Envelope Envelope Envelope Envelope Envelope Envelope C402.5.2, C402.5A Envelope C402.5.3 Envelope Air Leakage C402.5.5, Envelope C403.2.4.3 Air Leakage C402 5.5, Envelope C403.2.4.3 Air Leakage C402,5-6 Envelope Roof insulation installed per manufacturerAET"s instructions. Blown or poured loose -fill insulation is installed only where the roof slope is <=3 in 12 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Fenestration products rated in accordance with NFRC. Fenestration products are certified as to performance labels or certificates provided. Floor insulation installed per manufacturer's instructions. Cavity or structural slab insulation installed in permanent contact with underside of decking or structural slabs. Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities, Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Non -swinging opaque doors have R-4.75 insulation. Skylight curbs are insulated to the level of roofs with insulation above deck or R-5. Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Building envelope contains a continuous air barrier that has been tested and deemed to limit air leakage <= 0 40 cfm(ft2. The building envelope contains a continuous air barrier that is sealed in an approved manner and either constructed or tested in an approved manner. Air barrier penetrations are sealed in an approved manner. All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor -permeable wrapping material to minimize air leakage. The building envelope contains a continuous air barrier that is sealed in an approved manner and material permeability — 0 004 cfm/ft2. Air barrier penetrations are sealed in an approved manner. The building envelope contains a continuous air barrier that is sealed in an approved manner and average assembly air leakage <= 0.04 cfmlft2. Air barrier penetrations are sealed in an approved manner. Factory -built fenestration and doors are labeled as meeting air leakage requirements. Where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening are located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope Stair and elevator shaft vents have motorized dampers that automatically close. Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Weatherseals installed on all loading dock cargo doors. F M N=0 EnergyGauge SummitO FlatCom-2017. TAM 2017-1.0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 16 434 Air Leakage C402 5,8 Envelope Recessed luminaires in thermal envelope to limit 1:1 El 1:1 infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing, HVAC C403,2,1 Mechanical HVAC systems and equipment design loads calculated in accordance with ANSI/ASHRAE/ACCA Standard 183 or by an approved equivalent Computational procedure SYSTEM —SPECIFIC C403,2,10 Mechanical HVAC piping insulation thickness. Where piping El El 1:1 is installed in Or Linder a slab, verification may need to occur during Foundation Inspection. HVAC C403 2 3 Mechanical HVAC equipment efficiency verified. SYSTEM —SPECIFIC C403 2,3 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. labeled for replacement only as per Footnote b to SYSTEM —SPECIFIC C403,2A,1 Mechanical Heating and cooling to each zone is controlled by a thermostat control Minimum one humidity control device per installed humid ification/dehumidification system. SYSTEM —SPECIFIC C4012A 11 Mechanical Heat pump controls prevent supplemental electric resistance heat from coming on when not needed, HVAC C403 2,4,1,2 Mechanical Thermostatic controls have a 5 A'F deadband. El 1:1 1:1 HVAC C403 2 4,1 2 Mechanical Thermostatic controls have a 5 A'F deadband, HVAC C403,2,41,3 Mechanical Temperature controls have setpoint overlap El 1:1 D HVAC C403,2,42,1, Mechanical Automatic Controls: Setback to 55'F (heat) and El El El C4012A 2 2 85'F (cool), 7-day clock. 2-hour occupant override, 10-hour backup SYSTEM —SPECIFIC C403,2 4,2,3 Mechanical Systems include optimum start controls. HVAC C403 2 45, Mechanical Snowlice melting system sensors for future C403 2 4,6 connection to controls Freeze protection systems have automatic controls installed. HVAC C4032,6 2 Mechanical Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design HVAC C403,2,9 Mechanical HVAC ducts and plenums insulated, Where ducts El or plenums are installed in or under a slab, verification may need to occur during Foundation SYSTEM —SPECIFIC C403,2,9 1,3 Mechanical Ductwork operating >3 in water column requires air leakage testing SYSTEM —SPECIFIC C403 4,1 2 Mechanical VAV fans have static pressure sensors located so SYSTEM_SPECIFIC C403,4,2,2 Mechanical Two -pipe hydronic systems using a common distribution system have controls to allow a for at least 4 hrs before changeover. and have rest controls to limit heating and cooling supply temperature to <=30 IF, SYSTEM —SPECIFIC C403,4,2 33 Mechanical Two -position automatic valve interlocked to shut El M 1:1 off water flow when hydronic heat pump with pumping system >10 hp is off, SYSTEM —SPECIFIC C403 44.5, Mechanical Zone controls can limit Simultaneous heating and C403AA,5,1-4 cooling and sequence heating and cooling to each SYSTEM —SPECIFIC C403 4 5 Mechanical Condenser heat recovery system that cain heat water to 850F or provide 60% of peak heat rejection is installed for preheating of service hot water SYSTEM —SPECIFIC C403 4 6 Mechanical Hot gas bypass limited to, SYSTEM —SPECIFIC C404,3 Mechanical Heat traps installed on non -circulating storage El 1:1 M water tanks. EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1,0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) Energy Conservation |ECC2015 Total Building Performance Compliance Option 1/23/2018 Page 17"r]4 SYSTEM —SPECIFIC C4043 Mechanical Heat traps installed on supply and discharge El 0 F] piping of non -circulating systems. SYSTEM —SPECIFIC C404,3 Mechanical Heat traps installed on supply and discharge piping of non -circulating systems, SYSTEM —SPECIFIC C404,6,1 Mechanical Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank. System return pipe is a dedicated return pipe or a cold water supply SYSTEM —SPECIFIC C404 6 1, C404 6 2 Mechanical pipe Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace SYSTEM —SPECIFIC C404,9,1 Mechanical Pool heaters are equipped with onloff switch and no continuously burning pilot light, SYSTEM —SPECIFIC C404.92 Mechanical Time switches are installed on all pool heaters 1:1 El and pumps, SYSTEM —SPECIFIC C404,92 Mechanical Time switches are installed on all pool heaters and pumps. SYSTEM —SPECIFIC C404 9 3 Mechanical Vapor retardant pool covers are provided for El heated pools and permanently installed spas Controls C405,2,1 Interior Lighting Lighting controls installed to uniformly reduce the lighting load by at least 50%. Controls C405 2 1 Interior Lighting Occupancy sensors installed in required spaces Controls C405Z1, Interior Lighting Independent lighting controls installed per C405,223 approved lighting plans and all manual controls readily accessible and visible to occupants, Controls C40522,1 Interior Lighting Automatic controls to shut off all building lighting installed in all buildings, Controls C405 2 3 Interior Lighting Daylight zones provided with individual controls that control the lights independent of general area lighting Controls C405 2 3, Interior Lighting Primary sidelighted areas are equipped with Controls C405,2,3, interior Lighting Enclosed spaces with daylight area under C405 2 3 1, skylights and rooftop monitors are equipped with C405Z3,3 required lighting controls. Controls C405 2 4 Interior Lighting Separate lighting control devices for specific uses installed per approved lighting plans. Wattage C405 2 4 Interior Lighting Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting Controls C405,2 5 Exterior Lighting Automatic lighting controls for exterior lighting installed, Controls will be daylight controlled, set based on business operation time -of -day. or reduce connected lighting > 30W Wattage C405A1 Interior Lighting Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Mandatory Additional Eff C406A Project Enhanced digital lighting controls efficiency package: Interior lighting has following enhanced lighting controls in accordance with Section Luminaires capable of continuous dimming and being addressed individually, — 8 luminaires controlled in Mandatory Additional Eff C4066 Project Dedicate outdoor air system efficiency package El Buildings with hydronic and/or multiple -zone HVAC systems are equipped with an independent ventilation system designed to provide >7 1 00-percent outdoor air to each individual occupied space, as specified by EnergyGaugeGummW0Fla/Com-2017,TAM 2O17-1.0Compliant Software. Effective Date: Dec 31.2817 Florida Building Code, Sixth Edition (2017)'Energy Conservation |EOC2015 Total Building Performance Compliance Option 1/ 23/2018 Page \VoG4 Mandatory Additional Eff C406 7, C406 7.1 Project Enhanced Service Water Heat System efficiency El 0 0 package, One of the following SWH system enhancements must satisfy 60 percent of hot water requirements, or 100 percent if the building otherwise complies with heat recovery per Section C403A 5: Waste heat re HVAC C408,2,2.1 Mechanical Air outlets and zone terminal devices have means for air balancing. HVAC C408.2.2.1 Mechanical Air outlets and zone terminal devices have means El for air balancing Testing C408IZ3,2 Mechanical HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Post Construction C303.3, C4082.52 Interior Lighting Furnished O&M instructions for systems and equipment to the building owner or designated representative, Post Construction C303,3, C408Z5,3 Mechanical Furnished O&M manuals for HVAC systems El 1-1 M within 90 days of system acceptance. Fenestration C402.4,2.2 Envelope Skylights in office, storage, automotive service, El 0 D manufacturing, non -refrigerated warehouse, retail store, and distribution/sorting area have a measured haze value > 90 percent unless designed to exclude direct sunlight, Post Construction C408,2,1 Mechanical Commissioning plan developed by registered El 1:1 M design professional or approved agency. Post Construction C408,2.3,1 Mechanical HVAC equipment has been tested to ensure proper operation - Post Construction C408.2,13 Mechanical Economizers have been tested to ensure proper El El M operation Post Construction C4082A Mechanical Preliminary commissioning report completed and El 1:1 1:1 certified by registered design professional or approved agency. Post Construction C408,2 5,1 Mechanical Furnished HVAC as -built drawings submitted within 90 days of system acceptance, Post Construction C408,2,5 1 Interior Lighting Furnished as -built drawings for electric power El 1-1 M systems within 90 days of system acceptance. Post Construction C408,2,5,3 Mechanical An air and/or hydronic system balancing report is provided for HVAC systems Post Construction C408 2,5 4 Mechanical Final commissioning report due to building owner within 90 days of receipt of certificate of Occupancy, Post Construction C408.3 Interior Lighting Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. EnergyGauge Summit} Fla/Com-2017. TAM 2017-1,0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/231,12018 Page 19 ot'34 Input Data Report Project Information Project Name: CLX Project Title: CLX Design Building Address: 301 South White Cedar Road State: Florida Zip: 32771 ONNner: Building Type: Of ice Building Classification: New Finished building No.of Stories: I GrossArea (SF): 19,065 Bldg. Rotation: 90 Deg Clockwise, Walls & Windows will, be rotated accordingly Zones No Acronym Description Type Area Multi 'TotalArea lsq Istl I one I Zone I CONI)l HONIVA) 604.0 1 604,0 2 one 2 Zone 2 CON I) I H ON I ' I ) 801.0 1 801.0 3 Zone 3 Zone 3 ON 1) 1 I'l ONF 1) 1644,0 1 1644,0 4 Zone 4 lone 4 CONI)H-IONFI) 937.0 1 937,0 5 lone 5 Zone 5 CONIA HONE ' 1) 2377.0 1 2377.0 6 Zone 011 Lone 611 CON 1) 11 ION F 1) 3896,0 1 3896.0 7 Zone 7 Zone 7 CONWI HONE[) 98.0 1 98.0 8 Zone 8 Lone 8 CONI)FIJON11 ' L) 2944.0 1 2944,0 9 Warehouse Warehouse UNCONI)EVIONED 5762.0 1 5762.0 10 OA-I OA-I CONI)I HONED 1.0 1 1.0 I I Zone 6A Zone 6A CONDI FIONIA) 1.0 1 H) EnergyGauge Summit@ Fla/Com-2017, TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/ 23/2018 Page 20 of'34 Spaces No Acronym Description Type Depth Width Height 1Iu11 Total Total Iftl IN IN Area vo[]ctl IS11 In Zone: Zone I I 101 OFFICE, K" 101 OFFICE KW Office - F-Inclosed 1 00 365.00 20-00 1 365.0 73000 2 l01 A I:X1:C CO! I01 A LXE.0 CONE Confcrencelmecting (Multiple 1 00 239.00 2000.t 239.0 4780.0 Functions) In Zone: Zone 2 1 107 OFFICE 107 OFFICE: Office - [Inclosed 1-00 124.00 20-00 1 124.0 2480.0 2 108 OFFICE U 108 OFFICE LJ Office - Enclosed 1.00 103-00 2000.1 103-0 2060-0 3 109 OFFICE SJ 109 OFFICE SJ Office - Enclosed 1 00 102.00 2000 1 102.0 20400 4 110 OFFICE 110 OFFICL Office - knclosed 1.00 99-00 20.00 1 99.0 1980.0 5 111 OFFICE I I I OFF ICE: Office - Enclosed 1.00 W 1 00 2000.1 101.0 2020.0 6 112 OFFICE, 112 OFFICE Office - Enclosed 1.00 9T00 2000.1 97.0 1940.0 7 113 CONITRI N 113 CONFE;RtiNCF. ConferenceFmceting (Multiple 1-00 175.00 2000.1 175.0 3500.0 Functions) In Zone: Zone 3 1 001 CORRIDOR 001 CORRIDOR Corndor 1.00 293-00 20-00 1 293.0 5860-0 El 2 002 CORRIDOR 002 CORRIDOR Corridor 1 00 135.00 2000.1 135-0 2700.0 3 102 OFFICE MS 102 OFFICE MS Office - Fncloscd 1.00 301.00 2000.t 30I.0 6020.0 4 103 OFFICE 11E3 103 OFFICE 1`113 Office - Enclosed 1-00 301.00 2000 l 301.0 6020.0 EJ 5 104 S I ORAGE 104 STORAGE: Storage & Warehouse - E3ulky 1.00 136.00 2000.I 136.0 2720.0 Active Storage. 6 114 OFFICE KL 114 OFFICE KL Office - Enclosed 1.00 2l 3,00 20-00 1 213.0 42600 7 115 OFFICE 115 OFFICE Office - Endosed 1 00 151,00 2000.t lit 0 3020.0 8 116 RR 116 RR Toilet and Washroom 1 00 57.00 2000.1 57.0 11400 9 118 RR 118 RR Toilet and Washroom 1 00 57-00 2000 1 57,0 1140-0 In Zone: Lone 4 1 105 EN'I`RY 105 ENTRY Lobby (General) - Reception 1.00 383-00 20-00 1 383.0 7660-0 and Waiting 2 106 MU111-USE 106 MULFI-USES Classroom/l,cctuw Hall 1 00 554.00 2000.1 554.0 110800 In Zone: Zone 5 1 120 OPEN OFFD 120 OPEN OFFICE Office - Enclosed 1.00 2028.00 20-00 1 2028.0 40560.0 2 122 RR 122 RR Toilet and Washroom 1.00 64.00 20-00 1 64.0 12800 3 123 RR 123 RR Toilet and Washroom 1.00 6.5.00 20.00 I 65-0 1300-0 4 124 RR 124 RR loilet and Washroom 1.00 204.00 2000.1 204.0 4080-0 El 5 120A S IORAGF 120A S LORAGL: Storage & W`arehouse - Bulk% 1 00 16-00 2000.1 16-0 320.0 Active Storage In Zone: 'hone 6B I 127 TRAINING 127 TRAINING Office - Enclosed 1.00 1998-00 2000.1 1998-0 39960.0 2 127ATRAININ( 12WIRAINING Office - Enclosed 100 I434.00 20.00 1 1434.0 28680.0 3 130 BREAK RO, 130 BREAK ROOM Office- Enclosed I-00 341.00 20.0) l 341.0 6820.0 EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 21 o(`34 4 131 OFFICE 131 OFFICE Ofl<ce- Enclosed 1-00 123-00 2000. t 123,0 2460.0 In Zone: `Lone 7 1 119 SERVER 119 SERVER I~:lectrical Mechanical 1.00 9800 2000. 1 980 1960-0 Equipment Room - General In Zone: Zone 8 l 121 OPEN OFFD 121 OPEN OFFICE 0111ice - Enclosed 1.00 2527,00 2000. 1 2527.0 50540.0 2 125 VEST 125 VEST Corridor 1.00 72.00 20.00 1 72-0 1440-0 3 126 RR 126 RR Toilet and Washroom 1.00 135-00 2000. 1 13-S O 2700.0 4 128 RISER 128 RISER Electrical Mechanical 1.00 2000. 20-00 1 200 400.0 Equipment Room General 5 121 A STORAGE 12 t A STORAGE Storage & Warehouse - E3ulky 1 00 2000. 20-00 1 200 400.0 Active Storage 6 132 CLOSFA 132 CLOSET Storage & Warehouse - Bulky 100 13900 20-00 1 139.0 2780.0 Aco4e Storage 7 117 MLCII 117 MECEI Electrical Mechanical 1.00 31.00 2000. 1 31.0 6200. Equipment Room - General In Zone: Warehouse I Warehouse Warehouse Storage & Warehouse - l0 00 576.20 2000. t 57620 1 15240.0 Inactive Storage In Zone: OA-I I Pi(Z0I0Spl GoOSpI Electrical Mechanical 1.00 1.00 1 00 l 1 l 0 Equipment Room - General In Zone: Zone 6A I PrOZoI ISpI 00SPI Ilectrical Mechanical 1 00 1 00 1 00 1 1 1.0 Equipment Room - General EnergyGauge Summit@ FlatCom-2017, TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Paige 22 of 34 No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire CWI Ctrl pts In Zone: Zone 1 In Space: 101 OFFICE KW t LED General Lighting 2 LED General Lighting In Space: IOIA EXEC CONF I LED General Lighting 2 LED General Lighting In Zone: Zone 2 In Space: 107 OFFICE LED General Lighting In Space: 108 (OFFICE L.I LED General Lighting In Space: 109 OFFICE S.) I LED General Lighting In Space: 110 OFFICE LED General Lighting In Space: III OFFICE; 1 LED General Lighting In Space: 112 OFFICE I LED General Lighting In Space: 113 ('ONFERENCE 1 LED General Lighting 2 L,I:D General Lighting In 'Lone: Zone 3 In Space: 001 CORRIDOR 1 LFD General Lighting In Space: 002 CORRIDOR I LED General Lighting In Space: 102 OFFI('E NIS I LED General Lighting In Space: 103 OFFI('E 11113 I,I>D General Lighting In Space: 104 STORAGE I LED General Lighting In Space: 114 OFFICE KL I I_,ED General Lighting In Space: 115 OFFICE 4 40 160 Manual WOW I 2 23 46 Manual Continuous I Dimming 8 23 184 Manual Continuous I Dimming 2 40 80 Manual Stepped-3 Level 1 1 40 40 Manual On/Off I 1 40 40 ManualOn/Off I 1 40 40 Manual0n/Ofl' 1 1 40 40 ManualOn/Of1' I 1 40 40 ManualOn/Ofl' I 1 40 40 ManualOn/Off 1 2 40 80 ManualOn/Ofl' I 4 23 92 Manual Continuous I Dimming 6 40 240 Manual Stepped-3 Level I 2 40 80 Manual Stepped-3 Level I 4 40 160 Manual WOW I 4 40 160 Manual0n/Off 1 2 40 80 ManualOn/Off I 2 40 80 Manual Stepped-3 Level I EnergyGauge Summit® FlalCom-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 23 of34 In Space: 116 RR I LED General Fighting 1 23 23 Occupancy sensor without I El Da lighting In Space: 118 RR I LED General Fighting 1 23 23 Occupancy sensor " ithout I Daylighting In Zone: Zone 4 In Space: 105 EN'FRY I I-ED General Lighting 6 40 240 Manual On/Col' I El In Space: 106 Nit L'I'l-USE I I El D General Lighting 6 40 240 OCCUpanc sensor without I El Da lighting In Zone: Zone 5 In Space: 122 RR in Space: 123 RR Daylighting In Space: 124 RR In Zone: Zone 613 In Space: 1271-RAINING I LED General Fighting 24 40 960 Manual Stepped-3 l,e\,el I El In Space: 127,VURAINING I Compact Fluorescent General Fighting 16 40 640 Manual Stepped-3 Le el I El In Space: 130 RREAK ROOM In Space: 131 OFFICIt" In Zone: Zone 7 In Space: 119 SERVER In Zone: Zone 8 In Space: 121 OPEN OFFWE I Compact Fluorescent Ocneral Fighting 29 40 1160 Manual Stepped-3 Level 2 D I LED General Fighting 1 40 40 Manual Stepped-3 Level I EJ In Space: 126 RR I Compact FILIONSCOW General Lighting In Space: 128 RISER EnergyGaugmSummit@Fla/Cum-2017,TAM 2017-1,0Compliant Software, Effective Date: Dec 31.017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 123/ 2018 Page 24"04 In Space: 132 CLOSET 1 111`11) General Lighting In Space. 117 NIE01 I 111"f) General Lighting In Zone: Warehouse In Space: Warehouse I I'L 1) General Lighting In Zone: 0A - I In Space: Pr0ZoI0SpI I Compact Fluorescent General Lighting In Zone: Zone 6A In Space: Pr0Zo1ISpI I Compact Fluorescent General Lighting 2 40 80 Occupancy sensor without I D I)a% lighting 1 23 23 Manual On/Ofl' I E-1 36 142 5112 NNIanual On/Off' 3 F-1 I I I Manual On/Ofy I I I ManUal 011/011' ID EnergyGauge Summit@ Fla/Com-2017, TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 25 of'34 Walls (Walls will be rotated clockwise by building rotation value) No Description UV Pe Width If (Effect, Multi Area Orient Cond- feat Dens. RA'alue In Zone: Zone I In Zone: zone 2 In Zone: Zone 3 In zone: Zone 4 In Zone: Zone 6B In Zone: Zone 8 EoergyGuuge8ummN@Fla/Com-2V17.TAM 2O17-1.0Compliant Software, Effective Date: Dec 31.017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 26"84 Windows (Windows will be rotated clockwise by building rotation value) No Description Orientation Shaded t ' sit(;C Vis.'Vra NN' 11 (Effec) Multi I'otalArea In Zone: Zone I In Wall: 10LA-W In Zone: Zone 2 In Wall: 108-N' In Zone: Zone 3 In Wall: 103-NN In Zone: Zone 4 In Wall: 105-S In Wall: 106-S In Zone: Zone6B In Zone: Zone 8 EnorgyGaugmSummwQFla/Com-2017.TAM 2O17-1.0Compliant Software. Effective Date: Dec 31.2017 Florida Building Code, Sixth Edition (2V17)'Energy Conservation |ECC2015 Total Building Performance Compliance Option 1/ 23D018 Page l7^84 Doors No Description Type Shade? Width 11 (Effee) Vlulti Area Cond. Dens, III: Crap. R IN IN plier Isfl Btu/h.sLFI Ilh/efl Btu/sf. Ih.sLF/ Fj Btul In Zone: In Wall: 0 Roofs do Description Type Width I (Effec) Multi Area lilt Cond. Ileat Cap Deus. R-Value IN Iftl plier Isl1 Idegl Btu/h.SC FI 113tu/sf. FI [ib/01 Ih.sfT/Btu In Zone: Zone I PrOZoI Rf1 RGDRoof 604.00 1.00 1 6040 0 00 0-0333 1 12 6.43 30-0 In Zone: Zone 2 1 Pr(Wo2Rfl RGDRoof 801.00 1.00 1 8010 0.00 0.0333 1.12 6.43 30.0 In Zone: Zone 3 1 Pr0Zo3Rl'l RGDRoof 1644-00 1-00 1 16440 0-00 0.0333 1,12 6.43 30.0 In Zone: Zone 4 1 Pr0/o4Rf1 RGDRoof 937,00 1.00 1 937.0 0.00 0-0333 1.12 6.43 30.0 0 In Zone: Zone S 1 PrWOJRfI RGDRoof 240.80 10-00 1 2408.0 0.00 0-0333 1 12 6-43 30.0 In Zone: Zone 6B I PrO/,o6Rfl RGDRoof 389.60 10.00 1 3896-0 0.00 0.0333 1.12 6.43 30.0 In Zone: Zone 7 1 PWORFl RGDRoof 98-00 1.00 1 98-0 0.00 0.0333 1.12 643 300 In Zone: Zone 8 1 PrWo8R,f1 RGDRoof 291.30 10.00 1 2913.0 0,00 0-0333 1.12 6.43 30.0 EnergyGauge Summitt Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1 /23/2018 Page 28 of 34 Skylights No Description Type tSit(;(' Vis.Trans §' II (Effec) Multi- Area Total Area iBtulltr sf 1`1 (fti IN prier isfi iSfi In Zone: In Roof: Floors No Description 'type Width 11 (Effec) Multi Area Cond. [teat Cap. Dens. 11-Value fti IN prier isfi (Btulh.sf.F 113tulsf. F) ilblcf] )b.sf.FlBtu In Zone: Zone I I PrOZo I F'I I I It soil, concrete 604-00 1 00 1 604-0 0-2681 34.00 1 1333 3 73 floor, carpet and rubber pad ln Zone: Zone 2 1 Pr0Zo2Fll 1 11 soil, concrete 80100 1.00 1 801.0 0.2681 34.00 113.33 3'73 floor, carpet and rubber pad In Zone: Zone 3 1 PrOZo3FII 1 ft soil, concrete 1644.00 1.00 1 1644.0 0.2081 34.00 113-33 3.73 floor, carpet and rubber pad In Zone: Zone 4 1 Pr0Z,o4FII I it soil, concrete 93700 1 00 1 937.0 0-2681 34.00 11333 3.73 floor, carpet and rubber pad In Zone: Zone S 1 I'COZo5H I I ft. soil, concrete 240.80 10 00 1 2408.0 02681 34.00 1 13-33 3.73 floor, carpet and rubber pad In Zone: Zone 6B I Pr0Zo6FI I 1 it soil, concrete 38960 10-00 1 3896.0 02681 34.00 113.33 3.73 floor, carpet and rubber pad In Zone: Zone 7 1 f`r0/o71:II I ft soil, concrete 98,00 1 00 1 98-0 02681 34.00 1 1333 3.73 floor, carpet and rubber pad In Zone: Zone 8 1 111W08F11 1 it soil, concrete 291.30 10-00 1 2913.0 0.2681 34.00 113-33 3.73 Floor, carpet and rubber pad EnergyGauge Summit@ FlalCom-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/ 23/2018 Page 29 of 34 Systems AHU/CU I System I Constant Volume Air Cooled No. Of Units A"U/Cli 2 System 2 Constant Volume Air Cooled No. Of Units Category Capacity Efficiency 1ptIVComponent AHU/CU 3 System 3 Constant Volume Air Cooled No. Of Units Al-JU/C[J 4 System 2 Constant Volume Air Cooled No. Of Units AUIU/CU 5 System 2 Constant Volume Air Cooled No. Of Units AUlU/C(j 6A System 2 Constant Volume Air Cooled No. Of Units Energy6auge8ummK@Ra/Cnm-2017,TAM 2017-1.0Compliant Software, Effective Dew Dec 31.%017 Florida Building Code, Sixth Edition (2817) Energy Conservation |ECC2015-Total Building Performance Compliance Option 1/ 23/2018 pqvc 30"G4 AHtJ/Ct,f 613 System 2 Constant Volume Air Cooled No. Of Units A HU/CU 8 System 2 Constant Volume Air Cooled No. Of Units Component CatesorN, Capacity Efficiency 11) IX OA-1 OA-1 Constant Volume Packaged No. Of 13nits System At( U / CU-7 All U / CU-7 Constant Volume Air Cooled No. Of Units Component Category Capacity Efficiency IPIA Water Heaters Ilk -11cater Description Capacity Cap.Unit 1/1, lit. Efficiency Loss EoorgyGommSummN@Fla/Com-2V17.TAM 2O17-1.0Compliant Software, Effective Date: Dec 31.2017 Florida Building Code, Sixth Edition (2017) Energy Conservation |ECC2015 Total Building Performance Compliance Option 1/ 23/2018 Page 3| ^[34 Ext-Lighting Description Category No. of NNatts per Area/Len/No Control Wattage Lumin- Lumin- sflft/Nol Type IW sires aire I Ext Light I Entry Canopies 3 23 172.50 Astronomical 7 imer C 69,00 2 Ext Light 2 Other (doors) than main 4 42 3,00 Astronomical 'tinier( 168.00 entries 3 Ext Light 3 Main entries 2 42 16.00 Astronomical Timer( 84.00 Piping I,y Operating Insulation Nomonal pipe Insulation Is No Re Temp Conductivity Diameter thickness Runout'. jrj j Btu-in/h.sU'l linj linj I Domestic and Service Hot Water 110.00 0,28 0.75 1.00 No Systems Fenestration Used Glass dame Glass'type No. of 5II(& VI.T C'anductance Panes utu/h.sUl ASI IULSgICIrAII User Defined 1 1.2500 0.8200 0,7000 Frm RGIWindow User Defined 1 0,5000 0.4800 0.7600 EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date'. Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 32 of 34 Materials Used Nlat No Acronym Description Only I2-Value Uscd RValue lh.sf.F/Btuj Chick IN Cond- uctivity BW/h.ft.F Density jib/CQ Sp.11cat jRtullh.Fj 264 NIM1264 AHWINUM. 1/16 IN No 0M002 0M050 26.0000 480.00 0.1000 178 N1atl178 CARPET WfRUBBE:R PAD Yes 1.2300 265 Matl265 Soil, I fi No 2.0000 1.0000 0.5000 100.00 0.2000 48 Matl48 6 in. I lea4yweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 23 Matl23 6 in. Insulation No 20,0000 0.5000 0.0250 5.70 0.2000 81 1VIatl81 ASPIIAI_;T-ROOFING, Yes 0.1500 El ROLL 244 Matl244 PLYWOOD.I121N No 0.6318 0.0417 0.0660 34.00 0.29oo II Matl11 2 in. 111SUlatlO No 6.0800 0.1670 0M250 2.00 0.2000 414 N1at1414 R-8 generic Insulatrion No 8.0000 0.1746 0.0218 0.30 0.2000 1001 ApLbMat1001 0.76 in. Insulation No 2.5240 0.0631 0.0250 5.70 0.2000 EnergyGauge Summit@) Fla1Com-2017. TAM 2017-1.0 Compliant Software, Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option I/2312018 Page 33 of34 4 Constructs Used Simple Massless Conductance Heat Cap Density RValue No Name Construct Construct (t3tu(hsEFt Il#tulsf.Ft (lb/ctj I11si'.Flt3tut 1002 _WI?Wall No No 0.10 0.32 11.59 10.5 Laver Material Material Thickness Framing No. IN Factor I 264 ALUMINUM, 1/ 16 IN 0.0050 0.000 2 414 R-8 generic lnsulatrion 0.1746 0.000 3 1001 0.76 in. Insulation 0,0631 0.000 Simple Nl tssless Conductance 11cat Cap Density RValue No Name Construct Construct l3hrlhsLFt Stulsf.Ft Ilhlctl hsf.FlBtut 1038 RGDRoot' No No 0.03 1.12 6.43 30.0 Layer Material Material Uhickness Framing No, IN Factor 1 81 ASPIIAIJ-R00l`ING, ROLL 0.000 2 244 111,YWOOD.1/21N 0,0417 0.000 3 23 6 in. Insulation 0.5000 0.000 4 11 2 in. Insulation 0,1670 0.000 5 1001 0.76 in. Insulation 0,0631 0.000 Simple ;Classless Conductance Heat Cap Density RValuc No Name Construct Construct It3tulhsf.ht l3tulsf.FJ Ihlcfj Ihsf.F/Btut 1057 1 fi. soil, concrete floor, carpet and No No 0.27 34.00 113.33 3.7 rubber pact Layer Material Material Thickness Framing No. IN Factor 1 265 Soil. 1 ft 1,0000 0.000 2 48 6 in. Heavyweight concrete 0,5000 0.000 3 178 CARPET W/RUBBER PAD 0.000 EnergyGauge Summit§ FlaiCom-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 1/23/2018 Page 34 ot'34 From: DeenJoy Sent: Tuesday, November 20,2Ul81Ui)5AK4 To: 'dmoss@gomezconstructionzom' Subject: 361 South White Cedar Road, Sanford Florida Building Permit Number 18-4433 I have approved the permit and plans for the above project under the condition that you submit two hard sets of product approvals as listed on sheet A-002 for review. Joy Deen City ofSanford Plans Examiner PH:4U7.88R,5O04 Grant Malta , Clerk Of The Circuit Court & Corn troller Seminole County, FL Inst #20181Y25826 Book.9243 Page:194; (1 PAGES) RCD: 11/02/2018 12:24:42 PM REC FEE $10.00 THIS tNaTRUAAENT A,E4 BY: ! Dawn MASSName: eZ GtN1 Gtt C Address venu r NOTICE OF COMMENCEMENT State of Florida County of Seminole t@ E R K 01F T b I( s a; at 1 Permit Number. Parcel ID Number: 26-19-30-5AE-04000000 The undersigned hereby gives notice that improvement will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following information Is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) 361 South White Cedar Rom 5anfQrd EL 32771 GENERAL DESCRIPTION OF IMPROVEMENT: Sitework and construction of new 1-story office building. OWNER INFORMATION: Name;_CLX Holdings, LLC Address: 645 Hickman Circle, Sanford FL 32771 Fee Simple Title Holder (if other than owner) Name: Address: CONTRACTOR: Name: Orlando Gomez/ Gomez Construction Company Address: 7100 SW 44th St Miami FL 33155 1750 Jackson Avenue Winter Park FL 32789 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: Address: in addition to himself, Owner Designates To receive a copy of the Uenoes Notice as Provided in Section 713.13(1)(b), Florlda Statutes. Expiration Date of Notice of Commencement (The expiration date Is 1 year from date of recording unless a different date Is specified) WMMQ T • ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART t, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.. iF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalti ury, I declare that I have read thejoregoing and that the facts stated In it are true tot o my edg ut"b lief. Kevin Wilcox Owners St9naN+ owners Piloted Name FWkte Statute 713,13(1)(g)9 ri sipn to mike of commencement and no one else may be permitted to sign in Ns or her stead.' State of 4.1lPV95i4l R>A County of .w K'i t r+ l CA—Ar— The foregoing Instrument was acknowledged before me this lilt` day of 1 1:14f rtl by t X- Who is personally known to me lit.__. Name of person makkg statement OR who has produced Identification type of identification produced: Revision Response to Comments 0 City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Permit# 18-0C)C QLMSS SubmittalDate- =Zlazlj f, I I Project Address:_ 3(a I S, Ct.1w Y-A Contact: Ph: (J(- Z"B Fax: (,40-7 Email: CL4*y kJ Trades encompassed in revision: 014uilding 0 Plumbing Ey'Electrical M"M'echanical 11 Life Safety El Waste Water Department El Utilities I Waste Water Planning Engineering El Fire Prevention 0 Building General description of revision: ROUTING INFORMATION Approvals